HomeMy WebLinkAboutPermit PG10-135 - WESTFIELD SOUTHCENTER MALL - ARDEN BARDEN B
680 SOUTHCENTER PY
PG1O-135
City *Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
Parcel No.: 9202470010
Address: 680 SOUTHCENTER MALL TUHW
Project Name: ARDEN B
Permit Number: PG10 -135
Issue Date: 10/11/2010
Permit Expires On: 04/09/2011
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name: MARGO KOZICH
Address: 2136 PURCELL DR , FERNANDINA BEACH FL 32034
Email: MARGOK @COMMERCIALPERMITSGROUP.COM
Contractor:
Name: BOND PLUMBING
Address: 1630 215 ST SW , LYNNWOOD WA 98036
Contractor License No: BONDP * *098K1
Phone: 904 - 491 -6314
Phone: 425 672 -8281
Expiration Date: 04/23/2011
DESCRIPTION OF WORK:
PLEASE REFER TO KEYED NOTES PAGE P100. REMODEL OF EXISTING RESTROOM
Value of Plumbing /Gas Piping:
Fees Collected:
Permit Center Authorized Signature:
$2,000.00
$154.88
Uniform Plumbing Code Edition: 2009
International Fuel Gas Code Edition: 2009
Date: l 0— L I ~1D
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the ance of I am authorized to sign and obtain this plumbing /gas piping permit.
a(4163 adeYd
C..,u/` S gohd
Signature:
Print Name:
Date: /0-1 1— ! D
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG10 -135 Printed: 10 -11 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 9202470010
Address:
Suite No:
Tenant: ARDEN B
680 SOUTHCENTER MALL TUKW
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG10 -135
ISSUED
09/29/2010
10/11/2010
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected m
accordance with the requirements of the building code.
11: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures
and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use
significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in
accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments.
13: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
14: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: Cond -10/06
PG10 -135 Printed: 10 -11 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
ecei/64- eor\-/
Date: �b —) /--16
ordinances governing
or local laws regulating
doc: Cond -10/06 PG10 -135
Printed: 10 -11 -2010
CITY OF TUKWIVII
Community DevelopmM Department
Permit Center
6300 Southcenter Blvd :, Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Plumbing/Gasirmit No. G10- t S
Project No..
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address:
aa° GtNrtz-
King Co Assessor's Tax No.: 90-19Z51/- DO /b
Tenant Name: �,eeew ,3
Property Owners Name:
Mailing Address:
Suite Number: 120 Floor:
New Tenant: ❑ Yes ❑..No
City
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: ////Q1e i0 ,XOT/
Mailing Address: ,o/ e:, 7&', GULL 4%.
Day Telephone: / t2 €/- 419/ ' 13/ 41
E -Mail Address: TT,1X 4?DA/. 6 aO /77t.%a..zaG rtgivv r,
(5 )400p- i C.G/-,%
PLUMBING / GAS PIPING CONTRACTOR INFORMATION
City �/ ' /State Zip O �
Fax Number: 90 - 419 -123i -
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
ARCHITECT OF RECORD — All plans must be stamped by Architect of Record
Company Name:
Mailing Address: 0/o4 '' AC/ 44Z1 'f'! 'TLS Z 0, Loy/ pe
City
Day Telephone:
Fax Number:
6"/"7 E vt t / /Pl�ou 6Tfs
Contact Person: F/-17
E -Mail Address:
State Zip
r
ENGINEER OF RECORD — All plans must be stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H:\ Applications\Porms- Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc
Revised: 7 -2010
bh
Page 1 of 2
S
Valuation of Project (contractor's bid pro $ / 000 p
Scope of Work (please provide detailed information): t -4*' /��'/ � ,V t /7107,/e,- /� ,/
6jt' J
0T poo /Ale . /'t/-4v#tt O2 6X /'Tip1/!7 A'00" 7
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:.
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub orr conibinatiom.' - - -
bath/shower
Bidet -
Clothes washer; domestic
... • . .
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,'
commercial
Floor Drain
Shower, single head trap
Lavatory
I
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
1
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
(
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
. •
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity), •
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
. '_,-
Repair or alteration of
water piping and /or water,
treatment equipment
Repair or alteration of
drainage or vent piping.
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas,
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets \ •.
PERMIT APPLICATION NOTES -
1
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may-grant one extension of time for an additional period not to exceed 180 days. ,The.extension,shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO.BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING QWN OR �1. . 1 ' .D GENT:
Signature: NV\
•
Date: li / G
10
Print Name: five- ,, /f %o70 L�iW rem/yr) Day Telephone: 1.0 -5/✓ --4 c195—
Mailing Address: 41Z° %H/ %�/ iTLN L %r P 7t/i�o OX 4 %/
/17/.6'W � NTLI D try State Zip
Date Application Accepted: _ ( O
Date Application Expires:
3 -)-c1- (
Staff Initials:
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc
Revised: 7 -2010
bh
144. 1
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
RECEIPT
Parcel No.: 9202470010 Permit Number: PG10 -135
Address: 680 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 09/29/2010
Applicant: ARDEN B Issue Date:
Receipt No.: R10 -02029
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $123.90
Payment Date: 10/11/2010 09:57 AM
Balance: $0.00
CURTIS BOND
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 461255
ACCOUNT ITEM LIST:
Description
123.90
Account Code Current Pmts
PLUMBING - NONRES
000.322.103.00.00 123.90
Total: $123.90
doc: Receiot -06 Printed: 10 -11 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 9202470010 Permit Number: PG 10 -135
Address: 680 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 09/29/2010
Applicant: ARDEN B Issue Date:
Receipt No.: R10 -01934
Initials:
User ID:
WER
1655
Payment Amount: $30.98
Payment Date: 09/29/2010 12:01 PM
Balance: $123.90
Payee: MIKE MONTGOMERY
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 928 30.98
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 30.98
Total: $30.98
doc: Receiot -06 Printed: 09 -29 -2010
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION �' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
CAI
PG to -135
Proj ct:
OUL--7-1\
Type of Inspection: ni
Date: 1 (
Address:
4.4
Date Called:
Special Instructions:
I
Date Wanted:
a
y
t (—(� L O %`
p.m.
Requester:
Phone N%
,6 l.o �-(( &..
a�
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
OUL--7-1\
Date: 1 (
(
( \.
n REINSPECTION FEE REQUIRED. Prior \to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 40. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OFTUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 4(206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
P60--j3
Project
a 2� ' L
4 (
Type o spection:
r nJ A- f p ( .L ,
Address:
( o X 0 S( !A
1 (
Date Called:
0 J4,-9,c A L dO SL)p-f
Special Instructions:
% ( &o---- LA Yc - _ Oti. W
Date Wanted:
/
c J �{a.ry.
( - 1 —/ P.m.
Requester:
, 7 2 - b Ii, it . —'-9 t -a -es s 5'
Phone 4 N
220 -4,5-174
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
4 (
(c -C) 061— i 0 4 ,
0 J4,-9,c A L dO SL)p-f
`-1-1) „ e fl rk..- „prod n
% ( &o---- LA Yc - _ Oti. W
0 -\%. r P r 1(--- 'r �S I r(1 a)4 ,
_
ck I), ()I- '
__I_A-3V\--Uk tpu
, 7 2 - b Ii, it . —'-9 t -a -es s 5'
A
'L--\),( /L. PS f, b 41-‘, L-kt r .S1
Inspector:
}1-
n REINSPECTION FEE REQUIREb. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite100. Call to schedule reinspection.
Date:
INSPECTION'NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Proj ct:
Type of Inspection:
Address:
if) W 6 SC- !-1 ALL—
Date Called:
Special Instructions:
Date Wanted:
a.m.
Requester:
Phone NA (
-1)75
444
• E Approved per applicable codes. Dedr<ections required prior to approval.
COMMENTS:
t A4,1) 7° � 1 4
,t,oe
Inspegor:
n REINSPECTION FEE REQUIRE
paid at 6300 Southcenter Blvd.
Date:
P for to next inspection, fee must be
. Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
1144(--066-09V
Typeof Inspection: (�
.i-0, ('_ if �-- Y . c`—=d�
Address:
//�� t ` (
6V S7 ■ �-1 �-�°'
Date Card. 6,1_ j4Q ock
Spe2t�l Instructions:
/-
Date Wanted: �.m
/ 0 -( --r .fl p.m.
Requester:
Phone No:
?./e, Co -77 y' _-7441
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
o
,1
Inspector:
Date D t s _/ 1
F-7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
• " t `' yr •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG10 -135 DATE: 09 -29 -10
PROJECT NAME: ARDEN B
SITE ADDRESS: 680 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Building Division
rub`c
(0
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
DUE DATE: 09-30-10
Complete Incomplete n Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Nr Structural Review Required ❑ No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions yj Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 10-28-10
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Peter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with Lal to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
BOND PLUMBING
4256728281
1630 215Th St Sw
Lynnwood
WA
98036
Snohomish
Individual
UBI No. 601319698
Status Active
License No. BONDP * *098K1
License Type Construction Contractor
Effective Date 5/21/1991
Expiration Date 4/23/2011
Suspend Date
Specialty 1 Plumbing
Specialty 2 Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
BOND, CURTIS
Owner
01/01/1980
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
RLI INS CO
SRS1008453
04/21/2002
Until Cancelled
$6,000.00
04/22/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
16
0010 CAS INS
BK01154441885
04/06/2010
04/06/2011
$1,000,000.0004
/08/2010
15
OHIO CAS INS
bko1154441885
04/06/2010
04/06/2011
$1,000,000.00
04/08/2010
14
MID-CENTURY
INS CO
604801254
03/01/2010
03/01/2011
$1,000,000.0003
/01/2010
13
OHIO CAS
GROUP
CT053059316
03/01/2008
03/01/2010
$1,000,000.00
02/20/2009
12
0010 CAS INS
BI-1053059316
03/01/2007
03/01/2008
$1,000,000.00
03/01/2007
11
FEDERATED
SERV /MUT INS
CO
9434493
02/01/2007
02/01/2008
03/27/2007
$1,000,000.0002
/13/2007
10
0010 CAS INS
BH053059316
04/21/2003
04/21/2007
$1,000,000.00
04/19/2006
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip /Print.aspx
10/11/2010
SEPARATE PERMIT
REQUIRED FOR:
L311tichaniael
irflectrical
D Pf tubing
Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
Permit No. !G i o'' 135
Plr.n review approval is subject to errors and omissions.
'\ .1 :t; ' ." ,I of construction documents does not authorize
s ; ntion 01 any adopted code or ordinance. Receipt
{ ' Lpprovt d Field Copy and conditions is acknowledged:
By acid-a;
Date: io /i/ /26 w
City Of Tukwila
BUILDING DIVISION
PLUMBING SPECIFICATIONS
GENERAL
ALL PLUMBING WORK INCLUDING INSTALLATION, EQUIPMENT, FIXTURES AND PIPING SHALL BE
INSTALLED IN STRICT COMPUANCE WITH LOCAL CODE AND ADOPTING ORDINANCES, AND
REGULATIONS SET FORTH BY THE AHJ (AUTHORITY HAVING JURISDICTION).
ROUTING OF ALL SANITARY PLUMBING, DOMESTIC WATER PIPING AND GAS PIPING AS SHOWN ON
THE PLANS IS SHOWN WITH THE INTENTION OF INDICATING THE APPROXIMATE LOCATION OF
EXISTING CONDITIONS, AND NEW ITEMS. PLUMBING CONTRACTORS SHALL VISIT THE JOBSITE TO
VERIFY JOBSITE CONDITIONS PRIOR TO SUBMITTING BIDS OR STARTING WORK. THIS
CONTRACTOR SHALL COORDINATE THE INSTALLA11ON OF HIS WORK WITH THE WORK OF ALL
OTHER TRADES TO AVOID INTERFERENCE. CONTRACTORS MAY DEVIATE FROM THE LOCATION
OF PIPING SHOWN IF INSTALLA11ON COMPLIES WITH LOCAL CODES AND INDUSTRY PRACTICES,
AND IF THE AHJ AND OWNER'S REPRESENTATIVE APPROVE. ITEMS NOT SHOWN ON THE PLANS
OR SHOWN IN CONFLICT WITH ANY CODE, REGULATION OR EXISTING CONDITION SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. THE CONTRACTOR IS
RESPONSIBLE FOR INSTAWNG ALL WORK IN ACCORDANCE WITH LOCAL CODES.
PRIOR TO SUBMISSION OF THE CONTRACTORS COST ESTIMATE FOR WORK INCLUDED UNDER THIS
PROJECT, THE CONTRACTOR SHALL VISIT THE JOBSITE TO EXAMINE ALL EXISTING CONDITIONS
RELATED TO HIS WORK, AND UPON ANAL EXAMINATION OF SUCH SHALL SUBMIT A FINAL
PROPOSAL AS EVIDENCE THAT THIS CONTRACTOR HAS VISITED SAID SITE AND VERIFIED ALL
EXISTING AND PROJECT CONDITIONS.
CLAIMS OF ADDITIONAL WORK OR ADD -ONS DUE TO NON - VERIFICATION OF EXIST. CONDITIONS
WILL NOT BE CONSIDERED BY THE OWNER. ALL ADDITIONAL WORK WHICH IS NOT CLEARLY
APPROVED PRIOR TO PERFORMANCE OF SUCH WORK WILL BE CHARGED TO THE CONTRACTOR,
AND IF NOT SETTLED WILL BE HELD FROM HIS FINAL PAYMENT.
MATERIALS;
DOMESTIC WATER PIPING:
WATER, PIPING SHALL BE TYPE -L COPPER WITH WROUGHT FITTINGS. LEAD -FREE SOLDER OR
SILVER SOLDER SHALL BE USED AT ALL POINTS OF CONNEC11ON. HANGERS SHALL BE EQUAL
CLEVIS TYPE HANGERS. HANGERS SHALL BE USED ON ALL PIPING, AT INTERVALS REQUIRED
BY CODE, THE CONTRACTOR SHALL ALLOW ADDITIONAL. CLEARANCE FOR EXPANSION AND
CONTRACTION FOR INSULATED AND NON- INSULATED PIPING.
DRAIN, WASTE AND VENT PIPING:
DRAIN WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON, AS REQUIRED BY CODE.
PVC SHALL NOT BE USED.
VALVES;
SHUT OFF VALVES SHALL BE EITHER GATE -TYPE OR BALL VALVES BY "CRANE ", "STOCKHAM
OR "POWELL" MIXING VALVES SHALL BE BY "LAWLER" OR APPROVED EQUAL BACKWATER
VALVES SHALL BE BY "ZURN" OR APPROVED EQUAL
PLUMBING SPECIALTIES:
HUB DRAINS SHALL BE CAST IRON FUNNEL DRAIN BY "WADE" WITH STRAINER.
AIR CHAMBERS: SHALL BE CONSTRUCTED OF TYPE -L COPPER, AIR CHAMBERS SHALL BE ONE
SIZE LARGER THAN THE SUPPLY PIPING, AND SHALL BE 18 INCHES LONG, PROPERLY CAPPED
AND SUPPORTED. FACTORY MANUFACTURED ITEMS CAN BE SUBSTITUTED AT THE CONTRACTORS
OPTION BY "NIBCO ", "WADE" OR EQUAL
CLEANOUTS: WALL CLEANOUTS SHALL HAVE STAINLESS STEEL COVERS AS MANUFACTURED
BY "WADE" OR APPROVED EQUAL FLOOR CLEANOUTS SHALL HAVE SATIN FINISH NICKEL TOP,
IN FINISHED AREAS, AND SATIN BRONZE CAP IN AREAS WHICH ARE NOT FINISHED. CLEANOUTS
SHALL BE MANUFACTURED BY "WADE" OR APPROVED EQUAL
FIXTURES: PLUMBING FIXTURES SHALL BE AS SPECIFIED ON THESE PLANS OR ON THE
ARCHITECTURAL PLANS. ALL FIXTURES SHOULD MEET ADA REQUIREMENTS WHERE APPLICABLE.
FIXTURES SHOULD BE OF THE HIGHEST QUALITY BY "AMERICAN STANDARD ", KOHLER" OR
APPROVED EQUAL
WATER HEATERS: IF NEW WATER HEATER(S) ARE TO BE INSTALLED THEY SHALL BE AS
SPECIFIED ON THE PLANS, AND SHALL BE OF COMMERCIAL GRADE, AND AGA APPROVED IF GAS
FIRED AND UL APPROVED IF ELECTRIC. HEATERS SHALL HAVE A 150 PSI WORKING PRESSURE
RATING. WATER HEATER INSTALLA11ON MANUALS SHALL BE GIVEN TO THE OWNER. WATER
HEATERS SHALL BE BY "STATE" OR BY "A.O.SMITH ".
GAS PIPING: ALL GAS PIPING SHALL BE SIZED IN ACCORDANCE WITH NFPA -54 THE NATIONAL
FUEL GAS CODE, AND SHALL BE INSTALLED IN CONFORMANCE WITH ANY LOCAL CODES WHICH
MAY DICTATE PIPE LABELING OR TESTING. GAS PIPING SHALL BE SCHEDULE 40 BLACK IRON
OR TYPE -L OR K COPPER IMTH BRAZED FITTINGS.
BUSHINGS ARE PROHIBITED, BELL REDUCERS SHALL BE INSTALLED AT REDUCTION IN PIPE SIZE.
GROUND JOINT UNIONS AND SHUTOFF VALVES SHALL BE INSTALLED AT ALL GAS APPLIANCES.
FLEXIBLE GAS LINES ARE PROHIBITED ON STATIONARY APPLIANCES AND SHALL ONLY BE
INSTALLED ON FULLY PORTABLE EQUIPMENT. A RESTRAINT CABLE SHALL BE ATTACHED TO
ANY FLEXIBLE CONNECTOR AND THE FLOOR SUCH THAT THE FLEXIBLE CONNECTOR CANNOT BE
OVER EXTENDED.
EXECUTION;
ALL PLUMBING FIXTURES, EQUIPMENT AND PIPING SHALL BE INSTALLED PER LOCAL CODE AND
ESTABLISHED INDUSTRY PRACTICES. LOCATE ALL PIPING, AS SHOWN ON THE PLANS.
COORDINATE WITH ALL OTHER TRADES TO AVOID INTERFERENCE., AND ADHERE TO ALL
SPECIFICATIONS AND MANUFACTURER GUIDELINES.
RUN ALL DOMESTIC WATER PIPING AS HIGH AS POSSIBLE. INSTALL HANGERS AND STRAPPING,
ALLOWING FOR EXPANSION AND CONTRACTION OF PIPING. DO NOT HANG OR SUPPORT OTHER
EQUIPMENT OR PIPING FROM WATER LINES. SEPARATE HOT AND COLD WATER LINES A
MINIMUM OF SIX (6) INCHES. INSULATE ALL PIPING WITH INSULATION WHICH MEETS OR
EXCEEDS 25/50 RATINGS.
INSTALL SOIL WASTE AND VENT PIPING WITH A MINIMUM SLOPE OF 1/4" PER FOOT IN THE
DIRECTION OF FLOW FOR DRAINS AND AGAINST THE FLOW OF VENT GASSES. NO FIXTURE
SHALL HAVE AN S -TRAP OR BE DOUBLE TRAPPED.
VALVES:
LOCATE VALVES SO AS TO BE ACCESSIBLE AND SO THAT SEPARATE SUPPORT CAN BE
PROVIDED WHEN NECESSARY. INSTALL ALL STEMS UPRIGHT. DO NOT INSTALL VALVES TO
PIPING OF DISSIMILAR COMPOSITION WITHOUT AN APPROVED DIELECTRIC FITTING.
TEST AND STERIUZA11ON:
TEST AND STERIUZE ALL PLUMBING PIPING INCLUDING DRAINS, WASTE VENTS AND WATER
PIPING PER LOCAL CODES AND REGULATIONS.
HANGER ROD
PIPE INSULATION
INSULATION SHALL BE RUN
CONTINUOUS THRU HANGERS
PIPE
INSULATION PROTECTION SHIELD. USE
16 GAUGE SHEET STEEL, 2 PIPE
DIAMETERS LONG, 120 DEGREES
SUPPORT, OR GRINNEL FIGURE 167.
PIPE HANGER DETAIL
SCALE: NONE
0 PLuABING KEYED NOTES 0
co CONNECT NEW 4" SANITARY TO EXISTING SANITARY UNE. FIELD VERIFY EXACT LOCATION, INVERT ELEVATION, AND DIRECTION OF
FLOW PRIOR TO INSTALLATIONS.
O CONNECT TO EXISTING 3/4" COLD WATER SERVICE STUBBED INTO SPACE. FIELD VERIFY EXACT LOCATION PRIOR TO
COMMENCEMENT OF WORK. INSTALL NEW WATER METER AND BACKFLOW PREVENTOR AS REQUIRED. COORDINATE READOUT
LOCATION WITH MAIL MANAGEMENT TEAM.
O PROVIDE AND INSTALL NEW WATER HEATER ABOVE CEIUNG AS SPECIFIED IN FIXTURE SCHEDULE ON THIS SHEET. SET
TEMPERATURE AT 110' F. INSTALL PER MANUFACTURES RECOMMENDATIONS. REFER TO DETAIL ON THIS SHEET.
O EXTEND NEW 2" VENT AND CONNECT TO EXISTING 4" VTR. COORDINATE EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK.
PLUMBNG CONTRACTOR'S NOTES
ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE
CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK
PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL
OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF
THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA
PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS
FAILURE TO VISIT THE JOB SITE.
PLUMBING FIXTURE SCHEDULE
PLUMBING SYMBOLS
CONNEC11ON DATA
SANITARY SEWER UNE
TPRV
TEMPERATURE PRESSURE RELIEF VALVE
MFG.
- -
VENT UNE
POC
POINT OF CONNECTION
TRAP
COL) WATER SUPPLY UNE
DF
DRINKING FOUNTAIN
—
1
HOT WATER SUPPLY UNE
MS
MOP SINK
— - - - - —
2N
SHUT -OFF VALVE
LAV
LAVATORY
D4
LAVATORY
BACKFLOW PREVENTER
WC
WATER CLOSET
N
VTR
VENT THRU ROOF
AFF
ABOVE FINISHED FLOOR
CI
CAST IRON
BFF
BELOW FINISHED FLOOR
FCO
FLOOR CLEAN OUT
EX
EXISTING
WCO
WALL CLEAN OUT
REL
RELOCATED
FD
FLOOR DRAIN
WH
WATER HEATER
0 PLuABING KEYED NOTES 0
co CONNECT NEW 4" SANITARY TO EXISTING SANITARY UNE. FIELD VERIFY EXACT LOCATION, INVERT ELEVATION, AND DIRECTION OF
FLOW PRIOR TO INSTALLATIONS.
O CONNECT TO EXISTING 3/4" COLD WATER SERVICE STUBBED INTO SPACE. FIELD VERIFY EXACT LOCATION PRIOR TO
COMMENCEMENT OF WORK. INSTALL NEW WATER METER AND BACKFLOW PREVENTOR AS REQUIRED. COORDINATE READOUT
LOCATION WITH MAIL MANAGEMENT TEAM.
O PROVIDE AND INSTALL NEW WATER HEATER ABOVE CEIUNG AS SPECIFIED IN FIXTURE SCHEDULE ON THIS SHEET. SET
TEMPERATURE AT 110' F. INSTALL PER MANUFACTURES RECOMMENDATIONS. REFER TO DETAIL ON THIS SHEET.
O EXTEND NEW 2" VENT AND CONNECT TO EXISTING 4" VTR. COORDINATE EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK.
PLUMBNG CONTRACTOR'S NOTES
ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE
CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK
PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL
OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF
THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA
PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS
FAILURE TO VISIT THE JOB SITE.
PLUMBING FIXTURE SCHEDULE
FIXTURE DATA
CONNEC11ON DATA
REMARKS
FIXTURE
QTY.
MFG.
CATALOG
NO.
COLOR
SOIL
SIZE
VENT
SIZE
TRAP
WATER
COLD
HOT
WATER CLOSET
1
*CRANE
31054
WHITE
4"
2N
2"
le
- --
1.6 GPF, 17 -1 /4" HIGH,
WHITE OPEN WINGED SEAT,
RIGHT HAND TRIP LEVER
BOWL MODEL #3954
TANK MODEL #3549
LAVATORY
1
*CRANE
1412 -20H
WHITE
2"
1 %4"
1 lb"
b"
1,
20"x18"
ONE THOLE VITREOUS US CHINA,
FLOOR DRAIN
1
*JOSAM
30000 -S -Z
- - --
3"
1 lb"
3"
- --
- --
w /6" STRAINE wl - r. p
pripwer
TRAP PRIMER
1
*WATTS
A200S
- - --
- --
- --
- --
1e
* OR APPROVED EQUAL
WATER HEATER SCHEDULE
PLAN
TAG
MFR.
MODEL #
CAPACITY
RECOVERY
WATTS
VOLTS
PHASE
TEMP. RISE
ELEMENT WATTS
LOWER
UPPER
WH -1
*A.O. SMITH
EJC -10
10 -GAL.
7 GPH
1650
120
1
60' F
1650
- - --
* OR APPROVED EQUAL
NOTE: PROVIDE DRAIN VALVE, T & P RELIEF VALVE, AND DRAIN PAN
HEAT TRAPS
EXPANSION TANK
ON CW SUPPLY
T&P REUEF
PIPE TO MOP
BASIN
GALVANIZED DRIP ����
PAN (BY PC) PLYWOOD PLATFORM (BY GC)
ABOVE CEIUNG
10
GROUND JOINT
UNION, (DIELECTRIC)
FINISH FLOOR
MOP BASIN
INDIRECT TO
MOP BASIN
AIR GAP =2X "d"
(5" MIN.)
WATER HEATER DETAIL
SCALE: NONE
0
•
PLUMBING PARTIAL PLAN
SCALE: 114'
NOTE: ALL WORK WILL BE SUBJECT TO
FIELD INSPECTION AND APPROVAL
2'',..-T
ce
"� i" I
2
I
N.- ^1
2"
A
4"
WC
MS
e
SANITARY RISER DIAGRAM
SCALE: NONE
'kr* <1
LAV
•
REVIEWED FOR
CODE COMPLIANCE
APDD(UFD
OCT 0 2010
4'Y-city of Tukwila
BUILDING rnviCIf1N
RECEIVED
SEP 29 2010
PERMIT CENTER
?GtO35
DOMESTIC WATER RISER DIAGRAM
SCALE: NONE