Loading...
HomeMy WebLinkAboutPermit PG10-135 - WESTFIELD SOUTHCENTER MALL - ARDEN BARDEN B 680 SOUTHCENTER PY PG1O-135 City *Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT Parcel No.: 9202470010 Address: 680 SOUTHCENTER MALL TUHW Project Name: ARDEN B Permit Number: PG10 -135 Issue Date: 10/11/2010 Permit Expires On: 04/09/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MARGO KOZICH Address: 2136 PURCELL DR , FERNANDINA BEACH FL 32034 Email: MARGOK @COMMERCIALPERMITSGROUP.COM Contractor: Name: BOND PLUMBING Address: 1630 215 ST SW , LYNNWOOD WA 98036 Contractor License No: BONDP * *098K1 Phone: 904 - 491 -6314 Phone: 425 672 -8281 Expiration Date: 04/23/2011 DESCRIPTION OF WORK: PLEASE REFER TO KEYED NOTES PAGE P100. REMODEL OF EXISTING RESTROOM Value of Plumbing /Gas Piping: Fees Collected: Permit Center Authorized Signature: $2,000.00 $154.88 Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: l 0— L I ~1D I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the ance of I am authorized to sign and obtain this plumbing /gas piping permit. a(4163 adeYd C..,u/` S gohd Signature: Print Name: Date: /0-1 1— ! D This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG10 -135 Printed: 10 -11 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Tenant: ARDEN B 680 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG10 -135 ISSUED 09/29/2010 10/11/2010 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected m accordance with the requirements of the building code. 11: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 13: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 14: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 PG10 -135 Printed: 10 -11 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: ecei/64- eor\-/ Date: �b —) /--16 ordinances governing or local laws regulating doc: Cond -10/06 PG10 -135 Printed: 10 -11 -2010 CITY OF TUKWIVII Community DevelopmM Department Permit Center 6300 Southcenter Blvd :, Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Plumbing/Gasirmit No. G10- t S Project No.. (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: aa° GtNrtz- King Co Assessor's Tax No.: 90-19Z51/- DO /b Tenant Name: �,eeew ,3 Property Owners Name: Mailing Address: Suite Number: 120 Floor: New Tenant: ❑ Yes ❑..No City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: ////Q1e i0 ,XOT/ Mailing Address: ,o/ e:, 7&', GULL 4%. Day Telephone: / t2 €/- 419/ ' 13/ 41 E -Mail Address: TT,1X 4?DA/. 6 aO /77t.%a..zaG rtgivv r, (5 )400p- i C.G/-,% PLUMBING / GAS PIPING CONTRACTOR INFORMATION City �/ ' /State Zip O � Fax Number: 90 - 419 -123i - Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: 0/o4 '' AC/ 44Z1 'f'! 'TLS Z 0, Loy/ pe City Day Telephone: Fax Number: 6"/"7 E vt t / /Pl�ou 6Tfs Contact Person: F/-17 E -Mail Address: State Zip r ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\ Applications\Porms- Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc Revised: 7 -2010 bh Page 1 of 2 S Valuation of Project (contractor's bid pro $ / 000 p Scope of Work (please provide detailed information): t -4*' /��'/ � ,V t /7107,/e,- /� ,/ 6jt' J 0T poo /Ale . /'t/-4v#tt O2 6X /'Tip1/!7 A'00" 7 Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type:. Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub orr conibinatiom.' - - - bath/shower Bidet - Clothes washer; domestic ... • . . Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder,' commercial Floor Drain Shower, single head trap Lavatory I Wash fountain Receptor, indirect waste Sinks Urinals Water Closet 1 Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent ( Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors . • Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity), • Grease interceptor for commercial kitchen ( >750 gallon capacity) . '_,- Repair or alteration of water piping and /or water, treatment equipment Repair or alteration of drainage or vent piping. Medical gas piping system serving 1 -5 inlets/outlets for a specific gas, Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets \ •. PERMIT APPLICATION NOTES - 1 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may-grant one extension of time for an additional period not to exceed 180 days. ,The.extension,shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO.BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING QWN OR �1. . 1 ' .D GENT: Signature: NV\ • Date: li / G 10 Print Name: five- ,, /f %o70 L�iW rem/yr) Day Telephone: 1.0 -5/✓ --4 c195— Mailing Address: 41Z° %H/ %�/ iTLN L %r P 7t/i�o OX 4 %/ /17/.6'W � NTLI D try State Zip Date Application Accepted: _ ( O Date Application Expires: 3 -)-c1- ( Staff Initials: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc Revised: 7 -2010 bh 144. 1 Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: PG10 -135 Address: 680 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 09/29/2010 Applicant: ARDEN B Issue Date: Receipt No.: R10 -02029 Initials: User ID: Payee: WER 1655 Payment Amount: $123.90 Payment Date: 10/11/2010 09:57 AM Balance: $0.00 CURTIS BOND TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 461255 ACCOUNT ITEM LIST: Description 123.90 Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 123.90 Total: $123.90 doc: Receiot -06 Printed: 10 -11 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: PG 10 -135 Address: 680 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/29/2010 Applicant: ARDEN B Issue Date: Receipt No.: R10 -01934 Initials: User ID: WER 1655 Payment Amount: $30.98 Payment Date: 09/29/2010 12:01 PM Balance: $123.90 Payee: MIKE MONTGOMERY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 928 30.98 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 30.98 Total: $30.98 doc: Receiot -06 Printed: 09 -29 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 CAI PG to -135 Proj ct: OUL--7-1\ Type of Inspection: ni Date: 1 ( Address: 4.4 Date Called: Special Instructions: I Date Wanted: a y t (—(� L O %` p.m. Requester: Phone N% ,6 l.o �-(( &.. a� Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: OUL--7-1\ Date: 1 ( ( ( \. n REINSPECTION FEE REQUIRED. Prior \to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 40. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 4(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P60--j3 Project a 2� ' L 4 ( Type o spection: r nJ A- f p ( .L , Address: ( o X 0 S( !A 1 ( Date Called: 0 J4,-9,c A L dO SL)p-f Special Instructions: % ( &o---- LA Yc - _ Oti. W Date Wanted: / c J �{a.ry. ( - 1 —/ P.m. Requester: , 7 2 - b Ii, it . —'-9 t -a -es s 5' Phone 4 N 220 -4,5-174 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4 ( (c -C) 061— i 0 4 , 0 J4,-9,c A L dO SL)p-f `-1-1) „ e fl rk..- „prod n % ( &o---- LA Yc - _ Oti. W 0 -\%. r P r 1(--- 'r �S I r(1 a)4 , _ ck I), ()I- ' __I_A-3V\--Uk tpu , 7 2 - b Ii, it . —'-9 t -a -es s 5' A 'L--\),( /L. PS f, b 41-‘, L-kt r .S1 Inspector: }1- n REINSPECTION FEE REQUIREb. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite100. Call to schedule reinspection. Date: INSPECTION'NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj ct: Type of Inspection: Address: if) W 6 SC- !-1 ALL— Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone NA ( -1)75 444 • E Approved per applicable codes. Dedr<ections required prior to approval. COMMENTS: t A4,1) 7° � 1 4 ,t,oe Inspegor: n REINSPECTION FEE REQUIRE paid at 6300 Southcenter Blvd. Date: P for to next inspection, fee must be . Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 1144(--066-09V Typeof Inspection: (� .i-0, ('_ if �-- Y . c`—=d� Address: //�� t ` ( 6V S7 ■ �-1 �-�°' Date Card. 6,1_ j4Q ock Spe2t�l Instructions: /- Date Wanted: �.m / 0 -( --r .fl p.m. Requester: Phone No: ?./e, Co -77 y' _-7441 Approved per applicable codes. Corrections required prior to approval. COMMENTS: o ,1 Inspector: Date D t s _/ 1 F-7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • " t `' yr • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -135 DATE: 09 -29 -10 PROJECT NAME: ARDEN B SITE ADDRESS: 680 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division rub`c (0 Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 09-30-10 Complete Incomplete n Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Nr Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions yj Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 10-28-10 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BOND PLUMBING 4256728281 1630 215Th St Sw Lynnwood WA 98036 Snohomish Individual UBI No. 601319698 Status Active License No. BONDP * *098K1 License Type Construction Contractor Effective Date 5/21/1991 Expiration Date 4/23/2011 Suspend Date Specialty 1 Plumbing Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date BOND, CURTIS Owner 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 RLI INS CO SRS1008453 04/21/2002 Until Cancelled $6,000.00 04/22/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 0010 CAS INS BK01154441885 04/06/2010 04/06/2011 $1,000,000.0004 /08/2010 15 OHIO CAS INS bko1154441885 04/06/2010 04/06/2011 $1,000,000.00 04/08/2010 14 MID-CENTURY INS CO 604801254 03/01/2010 03/01/2011 $1,000,000.0003 /01/2010 13 OHIO CAS GROUP CT053059316 03/01/2008 03/01/2010 $1,000,000.00 02/20/2009 12 0010 CAS INS BI-1053059316 03/01/2007 03/01/2008 $1,000,000.00 03/01/2007 11 FEDERATED SERV /MUT INS CO 9434493 02/01/2007 02/01/2008 03/27/2007 $1,000,000.0002 /13/2007 10 0010 CAS INS BH053059316 04/21/2003 04/21/2007 $1,000,000.00 04/19/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 10/11/2010 SEPARATE PERMIT REQUIRED FOR: L311tichaniael irflectrical D Pf tubing Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Permit No. !G i o'' 135 Plr.n review approval is subject to errors and omissions. '\ .1 :t; ' ." ,I of construction documents does not authorize s ; ntion 01 any adopted code or ordinance. Receipt { ' Lpprovt d Field Copy and conditions is acknowledged: By acid-a; Date: io /i/ /26 w City Of Tukwila BUILDING DIVISION PLUMBING SPECIFICATIONS GENERAL ALL PLUMBING WORK INCLUDING INSTALLATION, EQUIPMENT, FIXTURES AND PIPING SHALL BE INSTALLED IN STRICT COMPUANCE WITH LOCAL CODE AND ADOPTING ORDINANCES, AND REGULATIONS SET FORTH BY THE AHJ (AUTHORITY HAVING JURISDICTION). ROUTING OF ALL SANITARY PLUMBING, DOMESTIC WATER PIPING AND GAS PIPING AS SHOWN ON THE PLANS IS SHOWN WITH THE INTENTION OF INDICATING THE APPROXIMATE LOCATION OF EXISTING CONDITIONS, AND NEW ITEMS. PLUMBING CONTRACTORS SHALL VISIT THE JOBSITE TO VERIFY JOBSITE CONDITIONS PRIOR TO SUBMITTING BIDS OR STARTING WORK. THIS CONTRACTOR SHALL COORDINATE THE INSTALLA11ON OF HIS WORK WITH THE WORK OF ALL OTHER TRADES TO AVOID INTERFERENCE. CONTRACTORS MAY DEVIATE FROM THE LOCATION OF PIPING SHOWN IF INSTALLA11ON COMPLIES WITH LOCAL CODES AND INDUSTRY PRACTICES, AND IF THE AHJ AND OWNER'S REPRESENTATIVE APPROVE. ITEMS NOT SHOWN ON THE PLANS OR SHOWN IN CONFLICT WITH ANY CODE, REGULATION OR EXISTING CONDITION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR INSTAWNG ALL WORK IN ACCORDANCE WITH LOCAL CODES. PRIOR TO SUBMISSION OF THE CONTRACTORS COST ESTIMATE FOR WORK INCLUDED UNDER THIS PROJECT, THE CONTRACTOR SHALL VISIT THE JOBSITE TO EXAMINE ALL EXISTING CONDITIONS RELATED TO HIS WORK, AND UPON ANAL EXAMINATION OF SUCH SHALL SUBMIT A FINAL PROPOSAL AS EVIDENCE THAT THIS CONTRACTOR HAS VISITED SAID SITE AND VERIFIED ALL EXISTING AND PROJECT CONDITIONS. CLAIMS OF ADDITIONAL WORK OR ADD -ONS DUE TO NON - VERIFICATION OF EXIST. CONDITIONS WILL NOT BE CONSIDERED BY THE OWNER. ALL ADDITIONAL WORK WHICH IS NOT CLEARLY APPROVED PRIOR TO PERFORMANCE OF SUCH WORK WILL BE CHARGED TO THE CONTRACTOR, AND IF NOT SETTLED WILL BE HELD FROM HIS FINAL PAYMENT. MATERIALS; DOMESTIC WATER PIPING: WATER, PIPING SHALL BE TYPE -L COPPER WITH WROUGHT FITTINGS. LEAD -FREE SOLDER OR SILVER SOLDER SHALL BE USED AT ALL POINTS OF CONNEC11ON. HANGERS SHALL BE EQUAL CLEVIS TYPE HANGERS. HANGERS SHALL BE USED ON ALL PIPING, AT INTERVALS REQUIRED BY CODE, THE CONTRACTOR SHALL ALLOW ADDITIONAL. CLEARANCE FOR EXPANSION AND CONTRACTION FOR INSULATED AND NON- INSULATED PIPING. DRAIN, WASTE AND VENT PIPING: DRAIN WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON, AS REQUIRED BY CODE. PVC SHALL NOT BE USED. VALVES; SHUT OFF VALVES SHALL BE EITHER GATE -TYPE OR BALL VALVES BY "CRANE ", "STOCKHAM OR "POWELL" MIXING VALVES SHALL BE BY "LAWLER" OR APPROVED EQUAL BACKWATER VALVES SHALL BE BY "ZURN" OR APPROVED EQUAL PLUMBING SPECIALTIES: HUB DRAINS SHALL BE CAST IRON FUNNEL DRAIN BY "WADE" WITH STRAINER. AIR CHAMBERS: SHALL BE CONSTRUCTED OF TYPE -L COPPER, AIR CHAMBERS SHALL BE ONE SIZE LARGER THAN THE SUPPLY PIPING, AND SHALL BE 18 INCHES LONG, PROPERLY CAPPED AND SUPPORTED. FACTORY MANUFACTURED ITEMS CAN BE SUBSTITUTED AT THE CONTRACTORS OPTION BY "NIBCO ", "WADE" OR EQUAL CLEANOUTS: WALL CLEANOUTS SHALL HAVE STAINLESS STEEL COVERS AS MANUFACTURED BY "WADE" OR APPROVED EQUAL FLOOR CLEANOUTS SHALL HAVE SATIN FINISH NICKEL TOP, IN FINISHED AREAS, AND SATIN BRONZE CAP IN AREAS WHICH ARE NOT FINISHED. CLEANOUTS SHALL BE MANUFACTURED BY "WADE" OR APPROVED EQUAL FIXTURES: PLUMBING FIXTURES SHALL BE AS SPECIFIED ON THESE PLANS OR ON THE ARCHITECTURAL PLANS. ALL FIXTURES SHOULD MEET ADA REQUIREMENTS WHERE APPLICABLE. FIXTURES SHOULD BE OF THE HIGHEST QUALITY BY "AMERICAN STANDARD ", KOHLER" OR APPROVED EQUAL WATER HEATERS: IF NEW WATER HEATER(S) ARE TO BE INSTALLED THEY SHALL BE AS SPECIFIED ON THE PLANS, AND SHALL BE OF COMMERCIAL GRADE, AND AGA APPROVED IF GAS FIRED AND UL APPROVED IF ELECTRIC. HEATERS SHALL HAVE A 150 PSI WORKING PRESSURE RATING. WATER HEATER INSTALLA11ON MANUALS SHALL BE GIVEN TO THE OWNER. WATER HEATERS SHALL BE BY "STATE" OR BY "A.O.SMITH ". GAS PIPING: ALL GAS PIPING SHALL BE SIZED IN ACCORDANCE WITH NFPA -54 THE NATIONAL FUEL GAS CODE, AND SHALL BE INSTALLED IN CONFORMANCE WITH ANY LOCAL CODES WHICH MAY DICTATE PIPE LABELING OR TESTING. GAS PIPING SHALL BE SCHEDULE 40 BLACK IRON OR TYPE -L OR K COPPER IMTH BRAZED FITTINGS. BUSHINGS ARE PROHIBITED, BELL REDUCERS SHALL BE INSTALLED AT REDUCTION IN PIPE SIZE. GROUND JOINT UNIONS AND SHUTOFF VALVES SHALL BE INSTALLED AT ALL GAS APPLIANCES. FLEXIBLE GAS LINES ARE PROHIBITED ON STATIONARY APPLIANCES AND SHALL ONLY BE INSTALLED ON FULLY PORTABLE EQUIPMENT. A RESTRAINT CABLE SHALL BE ATTACHED TO ANY FLEXIBLE CONNECTOR AND THE FLOOR SUCH THAT THE FLEXIBLE CONNECTOR CANNOT BE OVER EXTENDED. EXECUTION; ALL PLUMBING FIXTURES, EQUIPMENT AND PIPING SHALL BE INSTALLED PER LOCAL CODE AND ESTABLISHED INDUSTRY PRACTICES. LOCATE ALL PIPING, AS SHOWN ON THE PLANS. COORDINATE WITH ALL OTHER TRADES TO AVOID INTERFERENCE., AND ADHERE TO ALL SPECIFICATIONS AND MANUFACTURER GUIDELINES. RUN ALL DOMESTIC WATER PIPING AS HIGH AS POSSIBLE. INSTALL HANGERS AND STRAPPING, ALLOWING FOR EXPANSION AND CONTRACTION OF PIPING. DO NOT HANG OR SUPPORT OTHER EQUIPMENT OR PIPING FROM WATER LINES. SEPARATE HOT AND COLD WATER LINES A MINIMUM OF SIX (6) INCHES. INSULATE ALL PIPING WITH INSULATION WHICH MEETS OR EXCEEDS 25/50 RATINGS. INSTALL SOIL WASTE AND VENT PIPING WITH A MINIMUM SLOPE OF 1/4" PER FOOT IN THE DIRECTION OF FLOW FOR DRAINS AND AGAINST THE FLOW OF VENT GASSES. NO FIXTURE SHALL HAVE AN S -TRAP OR BE DOUBLE TRAPPED. VALVES: LOCATE VALVES SO AS TO BE ACCESSIBLE AND SO THAT SEPARATE SUPPORT CAN BE PROVIDED WHEN NECESSARY. INSTALL ALL STEMS UPRIGHT. DO NOT INSTALL VALVES TO PIPING OF DISSIMILAR COMPOSITION WITHOUT AN APPROVED DIELECTRIC FITTING. TEST AND STERIUZA11ON: TEST AND STERIUZE ALL PLUMBING PIPING INCLUDING DRAINS, WASTE VENTS AND WATER PIPING PER LOCAL CODES AND REGULATIONS. HANGER ROD PIPE INSULATION INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS PIPE INSULATION PROTECTION SHIELD. USE 16 GAUGE SHEET STEEL, 2 PIPE DIAMETERS LONG, 120 DEGREES SUPPORT, OR GRINNEL FIGURE 167. PIPE HANGER DETAIL SCALE: NONE 0 PLuABING KEYED NOTES 0 co CONNECT NEW 4" SANITARY TO EXISTING SANITARY UNE. FIELD VERIFY EXACT LOCATION, INVERT ELEVATION, AND DIRECTION OF FLOW PRIOR TO INSTALLATIONS. O CONNECT TO EXISTING 3/4" COLD WATER SERVICE STUBBED INTO SPACE. FIELD VERIFY EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK. INSTALL NEW WATER METER AND BACKFLOW PREVENTOR AS REQUIRED. COORDINATE READOUT LOCATION WITH MAIL MANAGEMENT TEAM. O PROVIDE AND INSTALL NEW WATER HEATER ABOVE CEIUNG AS SPECIFIED IN FIXTURE SCHEDULE ON THIS SHEET. SET TEMPERATURE AT 110' F. INSTALL PER MANUFACTURES RECOMMENDATIONS. REFER TO DETAIL ON THIS SHEET. O EXTEND NEW 2" VENT AND CONNECT TO EXISTING 4" VTR. COORDINATE EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK. PLUMBNG CONTRACTOR'S NOTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. PLUMBING FIXTURE SCHEDULE PLUMBING SYMBOLS CONNEC11ON DATA SANITARY SEWER UNE TPRV TEMPERATURE PRESSURE RELIEF VALVE MFG. - - VENT UNE POC POINT OF CONNECTION TRAP COL) WATER SUPPLY UNE DF DRINKING FOUNTAIN — 1 HOT WATER SUPPLY UNE MS MOP SINK — - - - - — 2N SHUT -OFF VALVE LAV LAVATORY D4 LAVATORY BACKFLOW PREVENTER WC WATER CLOSET N VTR VENT THRU ROOF AFF ABOVE FINISHED FLOOR CI CAST IRON BFF BELOW FINISHED FLOOR FCO FLOOR CLEAN OUT EX EXISTING WCO WALL CLEAN OUT REL RELOCATED FD FLOOR DRAIN WH WATER HEATER 0 PLuABING KEYED NOTES 0 co CONNECT NEW 4" SANITARY TO EXISTING SANITARY UNE. FIELD VERIFY EXACT LOCATION, INVERT ELEVATION, AND DIRECTION OF FLOW PRIOR TO INSTALLATIONS. O CONNECT TO EXISTING 3/4" COLD WATER SERVICE STUBBED INTO SPACE. FIELD VERIFY EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK. INSTALL NEW WATER METER AND BACKFLOW PREVENTOR AS REQUIRED. COORDINATE READOUT LOCATION WITH MAIL MANAGEMENT TEAM. O PROVIDE AND INSTALL NEW WATER HEATER ABOVE CEIUNG AS SPECIFIED IN FIXTURE SCHEDULE ON THIS SHEET. SET TEMPERATURE AT 110' F. INSTALL PER MANUFACTURES RECOMMENDATIONS. REFER TO DETAIL ON THIS SHEET. O EXTEND NEW 2" VENT AND CONNECT TO EXISTING 4" VTR. COORDINATE EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK. PLUMBNG CONTRACTOR'S NOTES ALL OF THE PLUMBING /PIPING WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE JOB SITE. PLUMBING FIXTURE SCHEDULE FIXTURE DATA CONNEC11ON DATA REMARKS FIXTURE QTY. MFG. CATALOG NO. COLOR SOIL SIZE VENT SIZE TRAP WATER COLD HOT WATER CLOSET 1 *CRANE 31054 WHITE 4" 2N 2" le - -- 1.6 GPF, 17 -1 /4" HIGH, WHITE OPEN WINGED SEAT, RIGHT HAND TRIP LEVER BOWL MODEL #3954 TANK MODEL #3549 LAVATORY 1 *CRANE 1412 -20H WHITE 2" 1 %4" 1 lb" b" 1, 20"x18" ONE THOLE VITREOUS US CHINA, FLOOR DRAIN 1 *JOSAM 30000 -S -Z - - -- 3" 1 lb" 3" - -- - -- w /6" STRAINE wl - r. p pripwer TRAP PRIMER 1 *WATTS A200S - - -- - -- - -- - -- 1e * OR APPROVED EQUAL WATER HEATER SCHEDULE PLAN TAG MFR. MODEL # CAPACITY RECOVERY WATTS VOLTS PHASE TEMP. RISE ELEMENT WATTS LOWER UPPER WH -1 *A.O. SMITH EJC -10 10 -GAL. 7 GPH 1650 120 1 60' F 1650 - - -- * OR APPROVED EQUAL NOTE: PROVIDE DRAIN VALVE, T & P RELIEF VALVE, AND DRAIN PAN HEAT TRAPS EXPANSION TANK ON CW SUPPLY T&P REUEF PIPE TO MOP BASIN GALVANIZED DRIP ���� PAN (BY PC) PLYWOOD PLATFORM (BY GC) ABOVE CEIUNG 10 GROUND JOINT UNION, (DIELECTRIC) FINISH FLOOR MOP BASIN INDIRECT TO MOP BASIN AIR GAP =2X "d" (5" MIN.) WATER HEATER DETAIL SCALE: NONE 0 • PLUMBING PARTIAL PLAN SCALE: 114' NOTE: ALL WORK WILL BE SUBJECT TO FIELD INSPECTION AND APPROVAL 2'',..-T ce "� i" I 2 I N.- ^1 2" A 4" WC MS e SANITARY RISER DIAGRAM SCALE: NONE 'kr* <1 LAV • REVIEWED FOR CODE COMPLIANCE APDD(UFD OCT 0 2010 4'Y-city of Tukwila BUILDING rnviCIf1N RECEIVED SEP 29 2010 PERMIT CENTER ?GtO35 DOMESTIC WATER RISER DIAGRAM SCALE: NONE