Permit PG10-148 - SEE'S CANDIES
SEE'S CANDIES 17100 SOUTHCENTER PY PG10 -148 Parcel No.: Address: City o�I'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 7888920020 17100 SOUTHCENTER PY TUKW Project Name: SEE'S CANDIES Permit Number: Issue Date: Permit Expires On: PG10 -148 11/29/2010 05/28/2011 Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Contact Person: Name: Address: Email: TIM KIRCHER 400 ALLAN ST , DALY CITY CA 94014 TKIRCHER@SEES.COM Contractor: Name: BOGART CONSTRUCTION INC Address: 12 MAUCHLY BLDG F , IRVINE CA 92618 Contractor License No: BOGARCI934CO Phone: 650 245 -3193 Phone: 949 453 -1400 Expiration Date: 02/21/2011 DESCRIPTION OF WORK: COMPLETE REMODEL OF RESTROOM. ADD ADDITIONAL SINKS TO INCLUDE UNDER SLAB PIPING AND RELOCATED WATER LINES ABOVE CEILING. Value of Plumbing /Gas Piping: $10,000.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $178.50 International Fuel Gas Code Edition: 2009 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Date: OAP ned thi permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr�u construction or the performance of work. on the back of this permit. Signature: Print Name: /7011-441J e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions ,„) Date: //24/0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG10 -148 Printed: 11 -29 -2010 PERMIT CONDITIONS Permit No. PG 10 -148 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG 10 -148 Printed: 11 -29 -2010 CITY OF TUISILA Community Deve pment Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Peril/No. Mechanical Permit No. AA I 1� Plumbing/Gas Permit No. Public Works Permit No. Project No. CY. ; 714 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: .112 n61 2.-e-- 002-o Site Address: J -) J OC) 5r) . Cc -• @c-,--Al , L--1 Suite Number: .10' Floor: Tenant Name: , l 5 (_c v, u-- S 1 y., r - Fj New Tenant: ( Yes ❑ ..No Property Owners Name: \,J i Iv cl.-- o ,, i ,i--3 S=, Mailing Address:.3'e..-e, (c--1.–...5° 7 ' I ..,/'; I 6,: •.,- -; p-,9 Q.,--1 v .,1C:- el Fr c n cl' ; 1-2) : IL/ ? .---O City State CONTACT PERSON - who do we contact when your permit is ready to be, issued Name: Mailing Address: I-I 0 0 M c r 'j" j f e_ l. r E -Mail Address: :i `.." e _`_3 Zip Day Telephone: 625 J S ) 4 3 City State Zip Fax Number: 1-PS'. -3-5- 1 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 1-9 Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: ‘1")."1 A W r - C ( t Mailing Address:.���:� - ►^^ (77T- C – e,z.�63 3 AA— L v. )4 o l ►■t k'i 'j i'J 6 i City State Zip Contact Person: Imo' Li-- 0 ):S Day Telephone: (0OSS- 7 c55- .-] G- 0 E -Mail Address: IL, 0 fS o r\ _ VY) A (,CS ,C�Th. ax Number: L. o 4'15 ` 0 ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: ',Vv'in I- e, 1,-./1 AS5oC' c-)rt. --*yt Mailing Address: __ O n '5 x f (--. `j j ' SC i /0 m: v, r„i x,011,3 'my, ,c--.5--"),2---- 1 City State Zip Contact Person: «) ,1 5i:� ,�i` c. r\ cx; , Day Telephone: / 114.-C— 7S-50 E -Mail Address: Fax Number: C. t Lf '...)S I H:\Apphcanons\ponns- Applieadans On Irne\2010 Applications \7 - 2010 -Remit Application.doc Revised 7 -2010 bh Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid pic): $ ,l 0 0 c") On a CY0 Existing Building Valuation: $ Scope of Work (please provide detailed information): (v r., �,t � � '1, ''7 v� c 1 t s X r� �l \v\-0 f ) -j' b f) ,� .- �i; / J C v'� s� 1 v�` 1 ° i S ) 00 i� i` �.a `�J P� YES. 1 C l� Will there be new rack storage? ❑ Yes a.No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure .. New Type of, Constriiction per 'IBC Type of Occupancy per IBC lr` Floor rd Floor 3"d Floor 1 j ;O 3,j Floors Basement' J4 Accessory Structure's Attached Garage Detached Garage Attached Carport Detached Carport dY Covered Deck N Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: „a, Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms - Applications On Line \2010 Applications \7 -2010 - Permit Applicalion.doc Revised: 7 -2010 bh Page 2 of 6 PUBLIC WORKS PERMIT INFWATION - :206.433 -0179 ..: Scope of Work (please provide) detailed information): 60 cr- > f 0 cs s. Call before you Dig: 1-800-424-5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District '...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View ❑ .. Renton ❑... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) V Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ .. Right -of -way Use — Potential Disturbance ❑ ...Construction/Excavation/Fin - Right -of -way ❑ Non Right -of -way ❑ ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ ff FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applicatioas\Forms- Applimrions On line\2010 Applications \ 7-2010 - Permit Application :doc Revised: 7 -2010 bh Page 3 of 6 MECHANICAL PERMIT INFOON - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: 1-75 Q Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ j ,c7O 0. Or) Scope of Work (please provide detailed information): 'L £_ 1)„ 1. 1 5O ��Sc r) c•v — Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ... Fuel Type: Electric ❑ Gas ..A Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling Incinerator - Domestic Other Mechanical Equipment System Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:Wpplications\Fonns- Applicanons On Line12010 Apphcanons17 -2010 - Permit Apphcanon.doc Revised: 7 -2010 bh Page 4 of 6 PLUMBING AND GAS PIPING PE•T INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name:"T f b. Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 4601 / 0 'o Vt D Valuation of Gas Piping work (contractor's bid price): $ At.= Scope off Work (please provide detailed information):(_ y,,p L c�,_ r.; \, J. rfC• ��,'eyyl c5tX��\ 0✓, c�� 7ivti��`, iY� v, L :,'hr,l�r �jfr�1 �'1(�! r∎t� �iI�Cc tC l,_.■r• CAW !7`�r`E C-J 1 h� Building Use (per Int'l Building Code): V P Occupancy (per Int'l Building Code): yvn Utility Purveyor: Water: V v'- i 1,..: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: 'i Fixture Type: Qty Fixture Type: Qty' . Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks z----- Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent / Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment 1 Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H: Applcations\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 5 of 6 PERMIT APPLICATION NOTES licable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF 1 STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OVVR A •`M 1 ENT: cam? Signature: Date: /0i 1 `l I I 0 Print Name: Mailing Address: 00 ! 5 I 1 Date Application Accepted: k 0 1...4 Day Telephone: /.S 4-10S ) 9 Ls vA C 1-1 U ` 6140/11 J City State Zip `/o Date Application Expires: °Li H:1Applicalions\Forms- Applications On Line\2010 Applications17 -2010 - Permit Application.doc Revised: 7 -2010 bh Staff Initials:' Page 6 of 6 GI/ of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R10 -02378 Initials: JEM Payment Date: 11/29/2010 User ID: 1165 Total Payment: 2,164.48 Payee: BOGART CONSTRUCTION INC. SET ID: 1129 SET NAME: SEE'S CANDIES SET TRANSACTIONS: Set Member Amount D10 -283 1,445.93 EL10 -0861 350.50 M10 -153 225.25 PG10 -148 142.80 TOTAL: 1,445.93 TRANSACTION LIST: Type Method Description Amount Payment Check 5308 2,164.48 TOTAL: 2,164.48 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE 000.322.100 000.322.101.00.0 000.322.102.00.0 000.322.103.00.0 640.237.114 TOTAL: 1,441.43 350.50 225.25 142.80 4.50 2,164.48 Ci f of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R10 -02156 Initials: JEM Payment Date: 10/25/2010 User ID: 1165 Total Payment: 1,080.04 Payee: SEE'S CANDIES, INC. SET ID: S000001437 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D10 -283 M10 -153 PG10 -148 TOTAL: 988.03 56.31 35.70 988.03 TRANSACTION LIST: Type Method Description Amount Payment Check 549984 1,080.04 TOTAL: 1,080.04 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES 000.322.100 30.97 000.345.830 1,049.07 TOTAL: 1,080.04 INSPECTION RECORD Retain a copy with permit INSPEC ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 2. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project: -,56-� (7,4Azdy Type of Inspection: ,c- >4/4z. -- ,0/2,,e0- 1.e /dif� Address: / 7 /,& .s��' ee ir- _ P9y Date Called: Special Instructions: ?'"- Date Wanted: /d? — Z i —/ O .m. Requester: Phone No: -? _e/7/— d6GC Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ins ector: Date: /2_,--7e r '� SPECTION FEE REQUIRED. ,Prior to next inspection, fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. II,S.P_E.CTION RECORD Retain a copy with permit P6/0- /`/ PERMIT NO. Ir -- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ■-5- s 151/ii,D/ Type of Inspection: A)P /(/./I-...Dv - sib/ ,if 6 Address: / 7/ 6, .5i�/7'4-Ni9e fo Date Called: Special Instructions: . Date Wanted: 1ln- Requester: Phone No: .. ' - • y7 /— ge) Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: Date: giI SPECTIN FEE JEQUIRED. Prior next inspection. fee must be d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PG '0 -4 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING_ DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 0 \-N c1' Type of Inspection: U fc6V,A i - COO 2e Address: [7 (© G Sett; -r- teen( Pc./ Date Called: Special Instructions: - Date Wanted: 12 - '2_ _ (0 el )in p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. 4- COMMENTS: 1 -4- Inspector: Date: n REINSPECTION FEE REQUIRED: Pri o'r to ext inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0 • City of Tukwila Jim Haggerton, Mayor Department of Co munity Development Jack Pace, Director November 2, 2010 Tim Kircher 400 Allan St Daly City, CA 94014 RE: Correction Letter #1 Plumbing /Gas Piping Permit Application Number PG10 -148 See's Candies —17100 Southcenter Py — Suite 108 Dear Mr. Kircher, This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. The Building Department has no comments at this time. Public Works Department: Dave McPherson at 206 431 -2448 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, —1:1° R111441/ Bill Rambo Permit Technician encl File: PG10 -148 W:\Permit Center\Correction Letters \2010\PG10 -148 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 CITY OF TUKWILA PUBLIC WORKS DEPARTMENT / REVIEW COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards DATE: October 27, 2010 PROJECT: See's Candies 17100 Southcenter Parkway Suite 108 Review Comment PERMIT NO: PG10 -148 PLAN REVIEWER: Contact David McPherson at (206) 431 -2448, if you have any questions /comments regarding the following comment. Provide a completed King County Non - Residential Sewer Use Certificate — see attached form. Only new plumbing fixtures shall be itemized, please do not list fixtures that will be replaced in kind. C ell\ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -148 DATE: 11 -15 -10 PROJECT NAME: SEE'S CANDIES SITE ADDRESS: 17100 SOUTHCENTER PY - STE 108 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division ❑ W rs iVr6s ‘ 'c Iic Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-16 -10 Complete ❑ Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 12 -14 -10 Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 WIT COW COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -148 DATE: 10/25/10 PROJECT NAME: SEE'S CANDIES SITE ADDRESS: 17100 SOUTHCENTER PY, STE 108 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: C 1� s''11 [vision tuilding iJ Publ` is Wor Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 10/26/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/23/10 Approved ❑ Approved with Conditions ri Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 1 \--)—U) Bldg ❑ Fire ❑ Ping ❑ PW41 Staff Initials: /�/� Documents/routing slip.doc 2 -28 -02 City of Tukwila Steven M Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1i/$1 / Plan Check/Permit Number: PG 10 -148 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: See's Candies Project Address: 17100 Southcenter Py — Suite 108 Contact Person: I i YYI 1 -.1 r Phone Number: ;I J ,S^ 0 �— 7 /'(A -C —� Summary of Revision: ¢.e. V \ �.c.� -- (a., y Vi 1 1� 1-., RECEIVED NOV 15 2010 f tRM)T CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms - applications on Tine \revision submittal Created: 8 -13 -2004 Revised: tgl King County Department of Natural Resources and Parks Wastewater Treatment Division Non- Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type q") ADO ,Soc-Alr.C2v.cir. 9ILL)L,//0 PrOpedy Street Address () City State ZIP 1-z`3 L_ Owner's Name Subdivision Name Lot # Subdiv. # Block # Building Name- %�� c L (if applicable) (t sa ) t qc 3 7 o ---) Owner's Phone Number (with Area Code) ( '�I /s'� )'.,1 OAS —)9.65 Property Contact Phone Number (with Area Code) Owner's Mailing Address ,9,T (i7;- 1 C iJ ` C �-. \ 'h ✓;� `dpi 4 J CO �J C -A3, L r 1 j • For King County ft Only Account # No. of RCEs Monthly Rate Property Tax ID # Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes ❑ No Was building on Sanitary Sewer? 0 Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. 01 Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 „i 6 Sink, Clinic flushing ,. 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 i 6 Water closet, tank or valve, >1.6 GPF 8 4 r Total Fixture Units ) Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units _ 20 o 'Y RCE B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B 0'3 N RCE RCE RECEIVE Nov 15 2010 BERM IT CENTER Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount,. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the c..acity charge levied will be based on this information and any deviation will require resubmission of correct data f de erm'-ation of a revised capacity charge. Signature of Owner /Representative Print Name of Owner /Representativ 1058 (Rev. 9/07) IC i r r White - Kina County Yellow - Local Sewer Acencv Pink - Sewer Customer Date //111 /0 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BOGART CONSTRUCTION INC UBI No. 602694207 Phone 9494531400 Status Active Address 12 Mauchly Bldg F License No. B0GARC1934CO Suite /Apt. License Type Construction Contractor City Irvine Effective Date 2/21/2007 State CA Expiration Date 2/21/2011 Zip 92618 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date BOGART CONSTRUCTION, INC. 02/20/2007 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 GREAT AMERICAN INS CO FS8017341 01/26/2007 Until Cancelled $12,000.00 02/21/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 VALLEY FORGE INS CO 4013738877 03/01/2010 03/01/2011 $1,000,000.0003 /04/2010 3 VALLEY FORGE INS CO 4013738877 03/01/2009 03/01/2010 $1,000,000.00 02/27/2009 2 AXIS SURPLUS INS CO EAP73124108 03/01/2007 03/01/2009 51,000,000.00 03/04/2008 1 LANDMARK AMERICAN INS CO LHA129399 03/01/2006 03/01/2007 $1,000,000.00 02/21/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 11/29/2010 IF YOU HAVE ANY QUESTIONS REGARDING THE MECHANICAL PLANS PLEASE CALL THE MECHANICAL DESIGNER. DESIGNER: DAN SJOSTRAND 612- 465 -7689 E -MAIL: dan.sjostrand©dunhameng.com EXISTING ROOFTOP UNIT SCHEDULE (RTU -1) MFGR. & MODEL EXISTING 6 TON GAS RTU WITH ECONOMIZER TO REMAIN. (YORK MODEL DF078N10P2AAA4A) CFM O.A. CFM 2,200 240 S.P H.P VOLTAGE UNIT WEIGHT EXISTING TO REMAIN 0.6" (EXT) SEE ELECTRICAL SEE ELECTRICAL HEATING CAPACITY (EXISTING) TOTAL MBH 64.8 MBH OUTPUT (81 MBH INPUT) THE MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR OF THE EXISTING EQUIPMENT AND ITS ACCESSORIES AS FOLLOWS: CLEAN ALL COILS, REPLACE THE FILTERS AND BELTS, INSPECT, REPAIR OR REPLACE THE ECONOMIZERS, DRIVES, FAN BEARINGS, MOTORS, CONTROL COMPONENTS, VALVES AND ANY OTHER ITEM NECESSARY FOR A COMPLETE AND PROPER OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE PRIOR TO BIDDING AND VERIFY ALL EXISTING SITE CONDITIONS. OUTDOOR AIR CALCULATION BASED ON 2009 INTERNATIONAL' MECHANICAL CODE TABLE 403.3 (WAG 51 -52 -0403. SECTION 403 — MECHANICAL VENTILATION. TABLE 403.3) RETAIL AREAS: BASEMENT AND STREET 0.30 CFM /SQ. FT. 595 SQ. FT. X 0.30 = 179 CFM RETAIL AREAS: STORAGE ROOMS 0.15 CFM /SQ. FT. 382 SQ. FT. X 0.15 = 57 CFM OUTSIDE AIR REQUIRED = OUTSIDE AIR PROVIDED = 236 CFM 240 CFM ROUND BALANCING DAMPER ROUND RIGID METAL DUCT PED INSULATION COVERING CONNECTION OF FLEX DUCT SUPPORT WITH METAL STRAPPING, DO NOT KINK INSULATED FLEXIBLE DUCT BALANCING HANDLE LOCK INTO POSITION AND MARKED PERMANENTLY. CEILING EXTENDED LENGTH OF ANY FLEXIBLE DUCT SHALL NOT EXCEED 5' —O" MAXIMUM OR LOCAL CODE. ��--- DIFFUSER STARTER COLLAR LAY —IN DIFFUSER NOTES: 1. PROVIDE AT FLEXIBLE DUCT CONNECTION METAL OR "PANDUIT" DRAWBAND ON THE INTERIOR FLEXIBLE DUCT HELIX. SECURE THE INSULATION OVER THE DRAW BAND WITH AN ADDITIONAL DRAWBAND. 2. PROVIDE BEADING ON ROUND METAL DUCT 12" OR LARGER IN DIAMETER. 3. PROVIDE MINIMUM 2" COLLARS FOR ATTACHMENT OF THE FLEX DUCT TO ROUND DUCT, DAMPERS AND DIFFUSERS. 4. BAND RIGID ROUND DUCT INSULATION TO DUCT AND PROVIDE TAPE FOR INSULATION OVERLAP. DIFFUSER /DUCT DETAIL NO SCALE EXHAUST FAN TAG MANUFACTURER MODEL NO. TYPE CFM S.P. WATTS VOLTAGE ACCESSORIES EF -1 GREENHECK SP -8110 CEILING 100 .25 80 SEE ELEC BACKDRAFT DAMPER NOTE: TOILET EXHAUST FAN SHALL BE INTERLOCKED WITH TOILET ROOM LIGHT SWITCH. DIFFUSER, GRILLE & REGISTER SCHEDULE EQUIP. TAG SERVICE TYPE MODULAR /FACE SIZE BACKPAN MANUF. MODEL NO DESCRIPTION MOUNTING TYPE PATTERN NOTES A SUPPLY SQUARE 24 " x24 " 18 "x18" CORE AREA TITUS PAS PERFORATED FACE LAY —IN 4 —WAY 1, 2 B RETURN SQUARE 24 "x24" SEE PLAN TITUS PAR PERFORATED FACE LAY —IN — 1 C SUPPLY SQUARE 12 "x12" CORE 6"x6" TITUS PAS PERFORATED FACE GYP. BRD. 4 —WAY 1, 2 NOTES: 1. ALL 2. PROVIDE GRILLES, REGISTERS & DIFFUSERS MUST BE PAINTED TO MATCH CEILING TILE COLOR. VERIFY EXACT COLOR WITH ARCHITECT. WITH OPPOSED BLADE DAMPER. VOLUME DAMPER AND SPIN —IN. TYPICAL FOR ALL. — EXTERIOR INSULATE[) ROUND RIGID DUCT (APPROPRIATELY SIZED) CAN BE SUBSTITUTED FOR RECTANGULAR DUCT SHOWN ON PLANS. (TYP) FLEX. DUCT 5' -0" MAX. LENGTH. TYPICAL FOR ALL. NEW TOILET EXHAUST FAN — ROUTE 6" RIGID DUCT W/ BACKDRAFT DAMPER UP THRU ROOF. TERMINATE IN A GOOSENECK W/ BIRD SCREEN — A MINIMUM OF 10' -0" FROM ALL O.A. INTAKES. VERIFY ROUTING AND LOCATION ON SITE — (100 CFM) EXISTING LANDLORD PROVIDED 5 TON GAS ROOF TOP UNIT (RTU -1) TO REMAIN. BALANCE AS SHOWN IN SCHEDULE. FYL COPY 8 Por'mlt No. 8 Plan review approval Is subject to erns and oil scions. Approval of construction documents does not authorize h� violation of any adopted code or ordinance. Receipt a approved Field Copy and conditions Is • By. Date: City Of BUILDING DIVISION MECHANICAL SYMBOLS x A -10 "r, 300 L_ A -10 "o 450 SUPPLY DIFFUSER RETURN GRILLE VOLUME DAMPER SMOKE DETECTOR DIFFUSER TYPE /NECK SIZE CFM REQUIRED Q THERMOSTAT A -10 "o 200 9 POINT OF CONNECTION REVISIONS No Changes shall be made to the scope of work „without prior approval of Tukwila-Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 10 "0 A -10 "0 I I 200 18/18 IF NOT ALREADY INSTALLED, FURNISH AND INSTALL A RETURN AIR DUCT SMOKE DETECTOR IN RTU -1 PER LOCAL CODE REQUIREMENTS. HVAC PLAN SCALE: 1 /4" = 1 -0" SPACE LOAD CALCULATIONS DESIGN TEMPS SUMMER 85 65 70 O.A.D.B. O.A.W.B I.A. D.B. DEG F DEG F DEG F GAINS SOLAR LOAD ROOF LOAD GLASS LOAD WALL LOAD LIGHTS PEOPLE PEOPLE (SENS) PEOPLE (LAT) MISCELLANEOUS VENT. VENTILATION (SENS) VENTILATION (LAT) 4,044 7,101 2,940 3,360 12,387 21 5,200 4,160 885 240 3,888 1,568 SENS. LOAD TOTAL LOAD TOTAL CFM WINTER O A D B 23 DEG F I A D B 70 DEG F BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H CFM BTU H BTU H 39,917 BTUH TOTAL 45,882 BTUH 2,200 LOSS 2,437 BTU H 9,870 BTUH 3,948 BTUH 12,182 BTUH 28,437 BTUH FURNISH AND INSTALL A NEW THERMOSTAT FOR RTU -1. THERMOSTAT SHALL BE A HONEYWELL COMMERCIAL VISION PRO #TB8220U1003 OR APPROVED EQUAL. MOUNT AT 4'- 0 "A.F.F. SEPARATE PERMIT REQUIRED FOR: PrMec hankst artlectrical Piping City of Tukwila BUILDING DIVISION , X REVIEWED FOR CODE COMPLIANCE APPROVED NOV 1 2010 c�y�r�ua� BUILDING DIVISION MECHANICAL NOTES 1. ALL EQUIPMENT, INSTALLATION AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING STUB —INS, TAPS, ETC. FOR PLUMBING AND MECHANICAL SYSTEMS WITHIN TENANT SPACE. 3. BRANCH DUCT RUN OUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERWISE SPECIFIED. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE SYSTEMS. COORDINATE ALL SYSTEMS IN THE FIELD. 6. VERIFY LOCATION OF ANY PENETRATION OF ROOF WITH LANDLORD. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE BY LANDLORD APPROVED ROOFING CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE. 7. ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE PERFORMED BY LANDLORD— APPROVED FIRE PROTECTION CONTRACTOR AT THE TENANT'S EXPENSE. 8. CONTRACTOR SHALL SUBMIT CERTIFIED AIR BALANCE REPORT INCLUDING ALL ASSOCIATED AIR TEMPERATURES AND PRESSURES AS APPLICABLE. SEND TWO COPIES TO OWNER FOR APPROVAL. 9. CEILING CONTRACTOR TO PROVIDE ADEQUATE ACCESS IN OPEN CEILING GRID AT DIFFUSER /DAMPER LOCATIONS FOR PURPOSE OF AIR BALANCING. 10. ALL SUPPLY AND RETURN AIR DUCTS IN PLENUM TO BE INSULATED PER LOCAL CODE REQUIREMENTS. 11. REMOVE ALL UNUSED HVAC EQUIPMENT, DUCTWORK, ACCESSORIES AND PIPING. DO NOT ABANDON. VERIFY CONDITIONS IN FIELD. PG110-142. DUNHAM M1 Dunham Associates, Inc. a South Suxth Street 1 Suite 1100 M %inneapo is, Minnesota 554024540 PROM 612.465.7550 FAX 612,40 x.7551'. wee duihameng.com mechanical + electrical consulting ertgir MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608 - 785 -2760 FAX: 608 -785- E —mail: officeOmba— architects.cc DEVELOPER'S SPACE NO. SUITE # CLIENT'S STORE NUMBER WA- SEE'S CANDIES SOUTHCENTER SQUi 17100 SOUTHCENTER PN TUKWILA, WA 9818E SEE'S CANDIES 400 ALLAN STREET DALY CITY, CA., 94014 PH: 415/ 405 -7965 FAX: 415/ 586 -8557 TIM KIRCHER CLIENT CONTACT (415) 405 -7965 Tim R. Benson ARCHITECT'S PROJECT MANAG 608/ 785 -2760 date c c o. contractor vendor 1 comr CUENT 10/07/10 0 BID / PERMIT 10/13/10 0 0 0 0 0 drown by: DS checked by: GS THIS SHEET CONTAINS: HVAC Plan RECEIVED CITY OF TUKWILA OCT 2 L010 PERMIT CENTER v 1 ARCHITECT'S COMMISSION NUME 10- 725.0E 3" V.T.R. 51 0 INDIRECT WASTE LINE FOR SKULLERY SINK SHALL BE COPPER WASTE & VENT PIPING RISER DIAGRAM NOT TO SCALE FIXTURE AND WATER CALCULATION TAG HOT AND COLD WATER WASTE CAPACITY (GAL) No OF FIXTURES F.U. PER FIXTURE TOTAL FIXTURE UNITS COMBINED a N No OF FIXTURES F.U. PER FIXTURE TOTAL FIXTURE UNITS 30 9 1 MARK DESCRIPTION CW HW P1 WATER CLOSET 1 1 5 2 5 1.5 ® 5 2 4" 11/2" 1 1 4 1 4 1 P2 LAVATORY 1 1/2" 3/4" P4, P6 HAND SINK 2 2 3 COUNTER TOP 4 11/2" 2 2 4 P3 MOP SINK 1 4 3 — 4 3" 1 3 3 FS FLOOR SINK i 1 iiL 4 3 / 3 — 4 3" 3" 1 1 5 3 5 3 P5 3 —COMP SINK — TOTAL F.U. 12" x12" TOP, 8" DEEP BODY, ALUMINUM DOME STRAINER, AND E -934 3/4 TOP GRATE (FLUSH WITH SLAB /FLOOR). (BY TENANT'S PLUMBING CONTRACTOR) WCO 15.5 10.5 19 < — ><- 20 W/ SQUARE POLISHED BRONZE ACCESS COVER AND FRAME. (BY TENANT'S PLUMBING CONTRACTOR) TOTAL F.U. 19 RANGE FT.x.43 ASSUMED 50 P.S.I. G.P.M 13 STREET STATIC PRESSURE LOSSES 10 LBS /100FT) LOSSES 5.00 PSI 4.30 PSI 3.00 PSI WATER METER STATIC HEIGHT PIPE LOSS (6 TOTAL 12.30 PSI ALL WATER SUPPLY LINES SHALL BE COPPER WATER PIPING RISER DIAGRAM NOT TO SCALE SYMBOLS/ ABBREVIATIONS GONIIIMMEI icy A.F.F. S.O.V. KEY NOTE UNDERGROUND SANITARY SEWER VENT HOT WATER COLD WATER BALL VALVE GATE VALVE ABOVE FINISHED FLOOR SHUT OFF VALVE POINT OF CONNECTION TO EXISTING ELECTRIC WATER HEATER SCHEDULE TAG MANUFACTURER MODEL NO. CAPACITY (GAL) KW STAGES OUTPUT (GPH ® 100 °F RISE) VOLTS NOTES WH -1 A.O. SMITH DEN -30 30 9 1 49 SEE ELEC (2) 4500 W HEATING ELEMENTS HEATING SIMULTANEOUSLY. (BY TENANT'S PLUMBING CONTRACTOR) PLUMBING FIXTURE SCHEDULE MARK TYPE MANUFACTURE AND MODEL NUMBER SUPPORT W V CW HW REMARKS P1 WATER CLOSET PRESSURE ASSIST AMERICAN STANDARD CADET (WHITE) 2168.100 FLOOR MOUNT 4" 2" 1/2,. — (BY TENANT'S PLUMBING CONTRACTOR) P2 LAVATORY AMERICAN STANDARD LUCERNE (WHITE) 0355.012 WALL HUNG 1 1/2" /2" 1 1/2" /2' 1/2" /2" 1 /2,. FAUCET: RELIANT 2385.404 (BY TENANT'S PLUMBING CONTRACTOR) P3 MOP SINK BASIN FLORESTONE MSR -2424 (MOLDED STONE) FLOOR MOUNT 3" 1 1/2" 3/4" 3/4" PROVIDE W/ MR -371 FAUCET, HOSE, HOSE BRACKET, MOP HANGER, MR -375 STRAINER, & MR -374 LOK SEAL. HOSE ATTACHEMENT ON FAUCET SHALL BE EQUIPPED WITH AN ANTI — SIPHON VACUUM BREAKER. (BY TENANT'S PLUMBING CONTRACTOR) P4 MINI —HAND SINK AMERICAN STANDARD — CHANDLER MODEL NO. 7182.803 COUNTER TOP 1 1 /2" 1 1 /2" 1 /2" 1 /2" FAUCET: AMERICAN STANDARD 7402.000 & #972 COLOR TO BE WHITE. (BY TENANT'S PLUMBING CONTRACTOR) P5 SCULLERY SINK RJ FABRICATORS MODEL NO. RJ- 1818 -18D (OWNER FURNISHED) FLOOR MOUNT 2" COPPER INDIRECT WASTE TO FS W/ 1" MIN. AIR GAP) — 3/4" 3/4" TENANT'S CONTRACTOR TO INSTALL OWNER SUPPLIED SCULLERY SINK, FAUCET (T &S B266) AND TRIM. P6 HAND SINK W/ SIDE SPLASH GUARDS ADVANCE ADVANCE MODEL NO. 7 —PS -66 WALL HUNG 1 1/2" 1 1/2" 1/2" 1/2" (BY TENANT'S PLUMBING CONTRACTOR) FS FLOOR SINK (SQUARE) COMMERCIAL ENAMELING MODEL NO. 908 -3 _ 3" 1-1/2" — — 12" x12" TOP, 8" DEEP BODY, ALUMINUM DOME STRAINER, AND E -934 3/4 TOP GRATE (FLUSH WITH SLAB /FLOOR). (BY TENANT'S PLUMBING CONTRACTOR) WCO WALL CLEAN OUT ZURN MODEL #ZB -1443 — — — — — W/ SQUARE POLISHED BRONZE ACCESS COVER AND FRAME. (BY TENANT'S PLUMBING CONTRACTOR) NOTE: EXCEPT FOR THE 3 —COMP SINK (P5), ALL PLUMBING FIXTURES AND ACCESORIES ARE TO BE SUPPLIED & INSTALLED BY CONTRACTOR. C2) PLUMBING PLAN SCALE: 1/4" = 1' -0" VACUUM BREAKER GATE /BALL VALVE (TYP.) c'— CW 3/4— THERMAL EXPANSION TANK: AMTROL; MODEL AST -5, OR EQUAL. TANK TO BE DIAPHRAGM TYPE, PRE — PRESSURIZED TO 40 PSIG AND RELIEF VALVE SET AT 150 PSIG. TANK SHALL BE ASME CERTIFIED. INSTALL PER MANUFACTURER'S RECOMMENDATIONS & LOCAL CODE REQUIREMENTS. 1" RUN FULL SIZE TO SERVICE SINK PER LOCAL CODE REQUIREMENTS DRAIN VALVE REFER TO ARCHITECTURAL DRAWINGS FOR WATER HEATER PLATFORM FRAMING DETAIL WATER HEATER DETAIL INSULATE ALL PIPING IN ACCORDANCE WITH SPECIFICATIONS. UNION (TYP.) 1" T & P RELIEF VALVE WATER HEATER 2" WIDE, 20 GA. SHEET METAL BAND, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE. GALV. DRIP PAN 1" DRAINS RUN IN WALL Sc PUNCHED OUT 1" ABOVE MOP SINK W/ AIR GAP NO SCALE REVIEWED FOR CODE COMPLIANCE APD1AVED NOV 16 2010 City of Tukwila BUILDING DIVISION KEY NOTES O CONNECT 4" SANITARY WASTE LINE TO EXISTING 4" SANITARY WASTE SERVICE. VERIFY TIE —IN LOCATION IN FIELD. ': EXTEND AND CONNECT NEW 2" VENT AND TERMINATE AT ROOF WITH 3" V.T.R.. TERMINATE A MIN. OF 10' -0" FROM ANY FRESH AIR INTAKES. VERIFY LOCATION IN FIELD. O3 EXTEND AND CONNECT NEW 3 /4 "CW LINE TO EXISTING MIN. 3/4" DOMESTIC COLD WATER SERVICE FOR TENANT'S SPACE. FIELD VERIFY EXISTING CONDITIONS. O ELECTRIC WATER HEATER TO BE INSTALLED ABOVE MOP SINK ON THE PLATFORM. SEE ARCHITECTURAL DRAWINGS FOR PLATFORM INFORMATION. O VERIFY WATER METER REQUIREMENTS WITH LANDLORD AND LOCAL WATER UTILITY CO. REQUIREMENTS. O ROUTE 3/4" CW DN IN WING WALL AND INSTALL MAIN SHUT —OFF VALVE AT 60" A.F.F.. AFTER SHUT —OFF VALVE, ROUTE 3/4" COLD WATER UP INTO CEILING PLENUM SPACE. REFER TO ARCHITECTURAL DETAIL 1/A5 AND WATER PIPING RISER DIAGRAM. COORDINATE ROUTING IN FIELD. GENERAL NOTES: 1. WELDING OR DRILLING OF STRUCTURAL MEMBERS IS NOT ALLOWED. 2. ABANDONED FLOOR DRAINS TO BE REMOVED PER STATE AND LOCAL CODES. 3. DO NOT RUN PIPING THRU, OVER OR UNDER ELECTRICAL EQUIPMENT AREA. PROVIDE CLEARANCE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. 4. ALL PIPING SHALL BE CONCEALED. SURFACE MOUNTED PIPING IS NOT ALLOWED. 5. PLUMBING CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL FOR EXACT FIXTURE LOCATION PRIOR TO ANY SAW CUTTING OR PLUMBING INSTALLATION. 6. THE TRENCH SHALL BE COMPACTED PRIOR TO POURING BACK AND THE SLAB SHALL BE PINNED AFTER ALL UNDERGROUND PLUMBING IS COMPLETED. 7. ALL IN —FLOOR MOUNTED FIXTURES ARE TO BE MOUNTED FLUSH WITH FLOOR. 8. PLUMBING WORK SHALL CONSIST OF FURNISHING AND INSTALLING ALL LABOR, MATERIALS AND EQUIPMENT TO COMPLETE ALL PLUMBING WORK SHOWN ON THE DRAWINGS AND /OR SPECIFIED. 9. INSTALL CLEAN —OUTS AT ALL BENDS, ANGLES AND ENDS OF ALL WASTE LINES AND ABOVE ALL CONNECTIONS IN WALLS OF SINK WASTE LINES. 10. ALL TRAPS, HOT WATER PIPES AND DRAIN PIPES SHALL BE INSULATED OR COVERED, BELOW LAVATORIES, AS PER CODE. 11. ALL WATER LINES SHALL BE COPPER. 12. PROVIDE CONTROL VALVES, ALL OF THE MIXING VARIETY, AS MANUFACTURED BY "AMERICAN STANDARD" OR APPROVED EQUAL. 13. PROVIDE SHUT —OFF VALVE INCOMING COLD WATER LINE AT PLUS 60" IN WING WALL ADJACENT TO 3 COMPARTMENT SINK WITH APPROVED ACCESS PANEL. 14. REMOVE ALL UNUSED PLUMBING FIXTURES, ACCESSORIES AND PIPING. DO NOT ABANDON. DUNHAM 21 Dunham Associates, inc. 50 South Sixth Street 'Suite 1100 Minneapolis,. Minnesota 65402• -1540 PHONE 6112.465.7560 FAX :812,4485.7551 was thinharne.riy.corn mechanical + electrical consulting engineering MBA Architects, Inc. 3823 Creekside Lane Hoimen, WI. 54636 608 - 785 -2760 FAX: 608-785-2750 E —mail: officeOmba— architects.com DEVELOPER'S SPACE NO. SUITE #108 CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 SEE'S CANDIES 400 ALLAN STREET DALY CITY, CA., 94014 PH: 415/ 405 -7965 FAX: 415/ 586 -8557 TIM KIRCHER CLIENT CONTACT (415) 405 -7965 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785 -2760 date client 1 6. 0 v permits contractor vendor comments REVIEW 10 %7/10 O BID / PERMIT 10/13/10 0 0 0 0 0 drown by DS checked by GS THIS SHEET . CONTAINS; FLOOR PLAN PLUMBING WORK RECEIVkD, CITY OF TUKwiLA OCT 'z 5 2010 PERMIT CENTER M2 ARCHITECT'S COMMISSION NUMBER 10- 725.069 MECHANICAL WORK INCLUDED: EACH CONTRACTOR SHALL VERIFY LANDLORD REQUIREMENTS. BID AND INSTALLATION SHALL BE BASED ON SUCH REQUIREMENTS. DRAWINGS AND SPECIFICATIONS. MECHANICAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES ON THE PROJECT PREVENTING UNNECESSARY CONFLICTS OR DELAYS DURING CONSTRUCTION. IF FOR ANY REASON EXISTING EQUIPMENT TO BE RE —USED NEEDS REPLACEMENT PARTS, THIS COST IS TO BE COVERED UNDER ORIGINAL CONTRACT AMOUNT AND WILL NOT BE ACCEPTED AS AN EXTRA COST OR EXPENSE. CONTRACTOR MUST INSPECT ALL EQUIPMENT TO BE RE —USED AT TIME OF BIDDING OR NEGOTIATING PERIOD. CONTRACTOR SHALL EXAMINE THE SITE, COMPARE IT WITH DRAWINGS AND SPECIFICATIONS AND BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO ALLOWANCE WILL SUBSEQUENTLY BE MADE IN BEHALF OF THIS CONTRACTOR BY REASON OF ANY ERROR ON HIS PART. CODES AND STANDARDS: ALL CODES, ORDINANCES, RULES, REGULATIONS, ORDERS, AND OTHER LEGAL REQUIREMENTS WITH WHICH COMPLIANCE IS REQUIRED BY GOVERNING AUTHORITIES SHALL BE ADHERED TO. TENANTS CONTRACTORS SHALL VERIFY WITH HVAC PLAN TO COORDINATE THE REQUIREMENT OF PLENUM RATED FIXTURES, PIPING, WIRING, ETC. FAILURE TO DO SO COULD RESULT IN THE REMOVAL AND REPLACEMENT OF THESE ITEMS AT NO ADDITIONAL COST TO THE TENANT. SCOPE A. THE WORK COVERED BY THIS. SPECIFICATION INCLUDES THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE WORK TO BE PERFORMED UNDER THE HEATING AND AIR CONDITIONING SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF ALL HEATING AND AIR CONDITIONING SYSTEM FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, THE FOLLOWING: 1. HEATING /COOLING UNITS 2. TOILET ROOM EXHAUST SYSTEMS 3. AUTOMATIC TEMPERATURE CONTROL 4. DUCTWORK AND AIR CONTROL 5. USE OF CRANE TO PLACE ROOF TOP EQUIPMENT (WHEN REQUIRED) GENERAL: A. THIS SPECIFICATION IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT IN OPERATION, THE COMPLETE HEATING AND AIR CONDITIONING SYSTEM. B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE WORK INCLUDED IN THIS CONTRACT. LAWS, ORDINANCES AND REGULATIONS: A. ALL SYSTEMS IN ALL AND /OR PART SHALL CONFORM TO ALL PERTINENT LAWS, ORDINANCES AND REGULATIONS OF ALL BODIES HAVING JURISDICTION, AT ALL GOVERNING LEVELS, NOTWITHSTANDING ANYTHING IN THESE DRAWINGS OR SPECIFICATIONS TO THE CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT LAWS SHALL APPLY. B. THE CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH HIS WORK. MATERIALS AND EQUIPMENT: A. ALL MATERIALS SHALL BE NEW AND SHALL BE OF THE TYPE AND SHALL MEET THE CAPACITIES OF EQUIPMENT SPECIFIED ON THE DRAWINGS. ALL MATERIALS AND EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA. B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS. C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED. WORKMANSHIP: A. ALL HEATING EQUIPMENT SHALL BE INSTALLED IN A WORKMANLIKE MANNER MEETING THE ACCEPTED STANDARDS OF THE HEATING INDUSTRY. THE WORK SHALL BE DONE BY SKILLED HEATING CRAFTSMAN, AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF ASHRAE AND /OR THE SMACNA MANUAL. CUTTING, PATCHING AND PAINTING: UNLESS OTHERWISE DIRECTED BY THE LANDLORD CRITERIA, THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING REQUIRED IN CONNECTION WITH HIS WORK. ALL FINISHED SURFACES THAT ARE CUT SHALL BE REPLACED IN KIND SO THAT THERE ARE NO VISIBLE EVIDENCE OF "PATCH ". PAINTING OF MECHANICAL WORK SHALL BE BY PRIME CONTRACTOR. ALL EQUIPMENT WHICH HAS HAD THE FINISH DAMAGED BY INSTALLATION OR TRANSPORTATION SHALL BE REFINISHED. ROOF AND OTHER PENETRATIONS: EACH CONTRACTOR REQUIRING OPENINGS IN THE ROOF OF THE BUILDING STRUCTURE (WHERE REQUIRED) SHALL MAKE ARRANGEMENTS WITH THE LANDLORD FOR SUCH OPENINGS. PROCEDURE AND COST ARRANGEMENTS SHALL BE OUTLINED IN THE LANDLORD CRITERIA. COMPLY WITH ALL LANDLORD REQUIREMENTS. ALL ROOF PENETRATIONS SHALL BE ARRANGED TO PROVIDE A WEATHER —TIGHT INSTALLATION. THE INSTALLATION SHALL INCLUDE, WHERE REQUIRED, VENTILATING COLLARS TO GIVE PROPER CLEARANCE FROM COMBUSTIBLE ROOFS, FLOORS, CEILINGS OR OTHER SUCH STRUCTURES. FIRE — PROOFING SHALL BE PROVIDED USING MATERIALS CONFORMING WITH MUNICIPAL CODES AND ORDINANCES. DUCTWORK: A. ALL DUCTWORK SHALL BE INSTALLED AS SHOWN ON MECHANICAL DRAWINGS. B. THE DUCTWORK SHALL BE CLEAR INSIDE OF THE SIZES SHOWN ON THE DRAWINGS. ALL DUCTS TO BE SHEET METAL DUCTS AS PER ASHRAE AND SMACNA GUIDLINES. C. FLEXIBLE DUCTS SHALL BE LIMITED TO 5' -0" MAX. FOR CONNECTION TO AIR DEVICES. D. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5' -0" ON CENTER. DUCTWORK MATERIALS SHALL BE PER CURRENT MECHANICAL CODE. DUCTWORK INSULATION: SUPPLY FROM THE AIR CONDITIONING UNIT SHALL BE WRAPPED WITH 1-1/2" THICK 1 LB /CUFT FIBERGLASS, FOIL BACKED INSULATION TO PREVENT CONDENSATION. GRILLES AND DIFFUSERS: GRILLES AND DIFFUSERS SHALL BE AS MANUFACTURED BY KREUGER, HART AND COOLEY, BARBERCOLMAN, OR TITUS. EACH IS TO BE FITTED WITH A VOLUME DAMPER. (OPPOSED BLADE DAMPER) TESTING AND BALANCING CERTIFIED (AABC OR NABB) INDEPENDENT TESTING COMPANY TO TEST AND BALANCE SYSTEM TO CFM AS SPECIFIED. REPORT RESULTS TO TENANT AND ARCHITECT. GUARANTEE: A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE OF OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD. B. THE GUARANTEE SHALL INCLUDE RESTORATION OF ITS ORIGINAL CONDITION OF ALL ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE. C. ALL SUCH REPAIRS AND /OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE CONVENIENCE OF THE OWNER. SUBSTITUTIONS: A. APPROVALS OF SUBSTITUTIONS FOR "APPROVED EQUAL ", MUST BE IN WRITING AND SUBSTITUTION MUST BE APPROVED BEFORE INSTALLATION. INSTALLATION WITHOUT PRIOR APPROVAL MAY RESULT IN CONTRACTOR REMOVING SUBSTITUTION AND REPLACING IT WITH SPECIFIED ITEM AT HIS EXPENSE. B. APPROVAL MAY BE GIVEN BY ARCHITECT, ENGINEER OR OWNER. TEMPERATURE CONTROL: FURNISH AND INSTALL NEW COMPATIABLE THERMOSTAT AS LISTED BELOW. A. THERMOSTAT SHALL BE A HONEYWELL COMMERCIAL VISION PRO #TB8220U1003 OR APPROVED EQUAL. TEMPERATURE CONTROL SHALL BE BY A WALL MOUNTED HEATING /COOLING THERMOSTAT, WITH SUBBASE HAVING SELECTOR SWITCHES FOR "ON /AUTO" AND "HEAT /OFF /COOL" TEMPERATURE RANGE FROM 50 DEGREES F. TO 90 DEGREES F. B. THIS STANDARD SYSTEM TO BE USED UNLESS SPECIAL CONTROL SYSTEM IS CALLED FOR OR SHOWN ON DRAWINGS. MECHANICAL UNIT: A. EXISTING LANDLORD PROVIDED GAS ROOF TOP UNIT (RTU -1) TO REMAIN. SEE SCHEDULE ON SHEET M1 FOR AIR BALANCE. B. SEQUENCE OF CONTROL (ROOF TOP UNIT) 1. OCCUPIED HOURS. A. UNIT OUTDOOR AIR DAMPER SHALL OPEN TO ITS MINIMUM POSITION AND UNIT SUPPLY FAN SHALL OPERATE CONTINUOUSLY. B. UNIT COMPRESSOR(S) SHALL CYCLE FOR COOLING AND THE GAS BURNER /FURNACE SHALL CYCLE FOR HEATING TO MAINTAIN SPACE SETPOINT. C UNIT ECONOMIZER CYCLE SHALL BE INITIATED UPON A SIGNAL FROM OUT DOOR AIR SENSORS. OUTDOOR AIR DAMPER, RETURN AIR DAMPER, AND UNIT COMPRESSOR(S) SHALL CYCLE TO MAINTAIN SPACE SETPOINT. 2. UNOCCUPIED HOURS. A. UNIT OUTDOOR AIR DAMPER SHALL REMAIN CLOSED AND UNIT SUPPLY FAN SHALL CYCLE ON A SIGNAL FROM SPACE SENSOR. B. UNIT COMPRESSOR(S) SHALL CYCLE FOR COOLING AND GAS BURNER /FURNACE SHALL CYCLE FOR HEATING WITH THE UNIT SUPPLY FAN TO MAINTAIN SPACE SETPOINT. FIRE: PROTECTION EXECUTION—INSTALLATION: A. GENERAL CONTRACTOR TO VERIFY MALL SPRINKLER CONTRACTOR REQUIREMENTS AND USE SPECIFIED CONTRACTOR IF REQUIRED. B. INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 13. INSTALL SPRINKLER PIPING PRODUCTS WHERE REQUIRED IN ACCORDANCE WITH RECOGNIZED PRACTICES TO ENSURE THAT FIRE PROTECTION SPRINKLER PIPING COMPLIES WITH GOVERNING REQUIREMENTS AND SERVES THE INTENDED PURPOSES. C. EXAMINE OTHER WORK SHOWN ON THE DRAWINGS AND CONDITIONS AT THE JOB SITE. COORDINATE THE ROUTING OF WORK WITH OTHER TRADES TO AVOID INTERFERENCE WITH OTHER INSTALLATIONS. D. PIPE ROUTING AND SPRINKLER HEAD LOCATIONS SHALL BE LOCATED AS REQUIRED TO AVOID EQUIPMENT, PLUMBING, HEATING AND AIR CONDITIONING PIPING, DUCTWORK, LIGHTING FIXTURES, ELECTRICAL CONDUITS AND BUS DUCTS AND SIMILAR WORK. E. PROVIDE PIPE OFFSETS AS REQUIRED TO COMPLETE THE INSTALLATION. MODIFY PIPE, PREFABRICATED PIPING, PIPE HANGERS AND OTHER COMPONENTS AS REQUIRED TO FIT THE: JOB SITE CONDITIONS. CLEANING AND FLUSHING: PRIOR TO CONNECTING SPRINKLER PIPING FOR FLUSHING, FLUSH WATER FEED MAINS, LEAD —IN CONNECTIONS AND CONTROL PORTIONS OF SPRINKLER PIPING. AFTER FIRE SPRINKLER PIPING INSTALLATION HAS BEEN COMPLETED AND BEFORE PIPING IS PLACED IN SERVICE, FLUSH ENTIRE SPRINKLER SYSTEM UNDER PRESSURE, AS REQUIRED TO REMOVE FOREIGN SUBSTANCES AS REQUIRED BY NFPA 13. CONTINUE FLUSHING UNTIL WATER IS CLEAR AND CHECK TO ENSURE THAT DEBRIS HAS NOT CLOGGED SPRINKLERS. TESTING: A. AFTER FLUSHING SYSTEM, TEST FIRE SPRINKLER PIPING HYDROSTATIC ALLY IN ACCORDANCE WITH NFPA 13, AT NOT LESS THAN 200 PSI OR AT 50 PSIG. CHECK SYSTEM FOR LEAKAGE AT JOINTS. MEASURE HYDROSTATIC PRESSURE AT LOW POINT OF EACH SYSTEM OR ZONE BEING TESTED. B. REPAIR OR REPLACE PIPING SYSTEM AS REQUIRED TO ELIMINATE LEAKAGE IN ACCORDANCE WITH NFPA STANDARDS FOR "LITTLE OR NO LEAKAGE' AND RETEST AS SPECIFIED TO DEMONSTRATE COMPLIANCE. SPRINKLER MANS AND BRANCHES A. PIPING MATERIAL: BLACK STEEL, SCHEDULE 40 OR LIGHTWEIGHT SPRINKLER PIPE, SCHEDULE 10 ASTM A 135 (IF ALLOWED BY LANDLORD AND LOCAL AUTHORITIES). B. FITTINGS: THREADED, CLASS 175. MECHANICAL COUPLINGS AND TEES OF A ROLLED GROOVED TYPE WILL BE ACCEPTED (IN LIEU OF THREADED) IF BOTH U.L. LISTED AND FIRE MARSHAL APPROVED. INSTALLATION: C. ALL SPRINKLER PIPING SHALL BE CONCEALED UNLESS OTHERWISE INDICATED. ALL PIPING SHALL BE LOCATED TO AVOID INTERFERENCE WITH ALL OTHER ELEMENTS ABOVE CEILINGS, ETC. D. SUPPORT ALL HORIZONTAL PIPING AT NOT GREATER THAN 10 FEET INTERVALS, EXCEPT PIPES OF SIZE 1-1/2" AND LARGER WHICH SHALL BE SUPPORTED AT NOT GREATER THAN FIFTEEN FEET INTERVALS, WITH APPROVED SWIVEL SPLIT RING HANGERS WITH ROD SUPPORTS AND SWAY BRACES AT EVERY THIRD HANGER. E. ALL SPRINKLER PIPING SHALL BE INSTALLED SO THAT IS CAN BE THOROUGHLY DRAINED AND WHERE PRACTICAL, ARRANGE TO DRAIN THE MAIN VALVE. SPRINKLER HEADS A. SPRINKLER HEADS IN AREAS WITH LAY —IN AND DRYWALL CEILINGS SHALL BE RECESSED TYPE: , 165 DEGREE RATED, CHROME PLATED HEAD WITH ESCUTCHEON COLOR TO MATCH CEILING COLOR, VERIFY EXACT COLOR WITH ARCHITECT. B. SPRINKLER HEADS IN AREA OF NO CEILING SHALL BE CHROME PLATED UPRIGHT. C. ALL SPRINKLER HEADS SHALL BE 1 /2" ORIFICE, RATED AT 165 DEGREES WITH A K— FACTOR OF 5.65. D. ALL SPRINKLER HEADS THAT ARE TO REMAIN AND BE REUSED SHALL BE PROTECTED DURING CONSTRUCTION AND CLEANED THOROUGHLY TO INSURE THAT THEY ARE CLEAR OF PAINT AND DEBRIS AND ARE IN GOOD WORKING CONDITION, PRIOR TO PROJECT CLOSEOUT. E. ALL SPRINKLER HEADS SHALL BE INSTALLED IN ACCORDANCE TO NFPA 13 AND ALL LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. PLUMBING SCOPE: A. THE WORK TO BE PERFORMED UNDER THE PLUMBING SPECIFICATIONS AND DRAWINGS CONSISTS OF FURNISHING ALL LABOR AND MATERIAL FOR THE COMPLETE INSTALLATION OF ALL PLUMBING SYSTEMS FOR TENANT SPACE. THE WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: 1. COLD AND HOT WATER SYSTEMS 2. DRAINAGE AND VENT SYSTEMS 3. INSULATION GENERAL: A. THIS SPECIFICATIONS IS INCLUSIVE FOR EACH ITEM REQUIRING ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO PROPERLY INSTALL, ALTER, ADJUST, AND PUT INTO OPERATION, THE COMPLETE PLUMBING SYSTEM . B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LAYOUT AND CONSTRUCTION OF THE WORK INCLUDED IN THIS CONTRACT. WORKMANSHIP: ALL WORK MUST BE DONE IN A WORKMANLIKE MANNER TO THE COMPLETE SATISFACTION OF THE ENGINEERS AND SHALL BE PERFORMED BY QUALIFIED MECHANICS. A. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, AND SHALL CONFORM TO THE GRADE, QUALITY AND STANDARDS SPECIFIED HEREIN. ALL MATERIALS AND EQUIPMENT UTILIZED SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA. B. ALL EQUIPMENT OFFERED UNDER THESE SPECIFICATIONS SHALL BE LIMITED TO PRODUCTS REGULARLY PRODUCED AND RECOMMENDED FOR SERVICE, IN ACCORDANCE WITH ENGINEERING DATA, RATINGS, OR OTHER COMPREHENSIVE LITERATURE MADE AVAILABLE TO THE PUBLIC AND IN EFFECT AT THE TIME OF OPENING OF BIDS. C. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR TYPE AND CAPACITY OF EACH PIECE OF EQUIPMENT USED. LAW, ORDINANCES AND REGULATIONS: A. ALL MECHANICAL SYSTEMS IN ALL AND /OR PART SHALL CONFORM TO ALL PERTINENT LAWS, ORDINANCES AND REGULATIONS AND ALL BODIES HAVING JURISDICTION, AT ALL GOVERNING LEVELS, NOTWITHSTANDING IN THESE PLANS AND SPECIFICATION TO THE CONTRARY. IN CASE OF CONFLICT BETWEEN GOVERNING LEVELS, THE MORE STRINGENT LAWS SHALL APPLY. B. CONTRACTOR SHALL PAY ALL FEES AND OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY ANY AUTHORITY HAVING JURISDICTION IN CONNECTION WITH HIS WORK. C. WHERE APPLICABLE, ALL MATERIAL SHALL BEAR THE THE NATIONAL BOARD OF FIRE UNDERWRITER'S SEAL OF APPROVAL. CERTIFICATES TO THIS EFFECT TO BE FURNISHED TO ARCHITECT TO BE TO ARCHITECT UPON REQUEST. ESCUTCHEONS: A. ALL EXPOSED PIPES, EXCEPT AS OTHERWISE DESCRIBED, PASSING THRU WALLS, FLOORS, CEILINGS, ETC. IN FINISHED SPACES, SHALL BE PROVIDED WITH SOLID PATTERN HEAVY CEILING, FLOOR OR WALL ESCUTCHEONS WITH SET SCREW. ESCUTCHEONS AND PLATES SHALL BE OF STEEL OR MALLEABLE IRON WITH PRIME COAT READY FOR PAINTING. ESCUTCHEONS WILL NOT BE PROVIDED WHERE SLEEVES INTENTIONALLY EXTEND ABOVE FINISHED FLOOR. B. ALL EXPOSED PLUMBING SHORT BRANCH CONNECTIONS TO FIXTURES AND /OR EQUIPMENT PASSING THROUGH WALL OR FLOORS SHALL BE EQUIPPED WITH PRESS BRASS, CHROMIUM PLATED, SOLID TYPE ESCUTCHEONS. GUARANTEE: A. EACH CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE IN WRITING ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY OWNER. THE CONTRACTOR SHALL PROVIDE FREE SERVICE FOR ALL EQUIPMENT INVOLVED IN HIS CONTRACT DURING THIS GUARANTEE PERIOD. B. THE GUARANTEE SHALL INCLUDE RESTORATION TO ITS ORIGINAL CONDITION OF ALL ADJACENT WORK THAT MUST BE DISTURBED IN FULFILLING THIS GUARANTEE. C. ALL SUCH REPAIRS AND /OR REPLACEMENTS SHALL BE MADE WITHOUT DELAY, AND AT THE CONVENIENCE OF THE OWNER. TEMPORARY SERVICES: A. THE CONTRACTOR, AT HIS OWN EXPENSE AND COST, SHALL INSTALL, OPERATE, PROTECT AND MAINTAIN THE RESPECTIVE TEMPORARY SERVICES AS REQUIRED BY HIS WORK. TEST OF PIPING AND SYSTEM: A. THE SYSTEMS OF PIPING AS INSTALLED BY THIS CONTRACTOR MUST BE TESTED WITH WATER OR AIR AND PROVEN TIGHT TO THE SATISFACTION OF REPRESENTATIVES OF THE OWNER. TESTING INSTRUMENTS MUST BE FURNISHED BY THE PLUMBING CONTRACTOR. B. TEST MUST BE MADE WITH WATER, EXCEPT WHEN THERE IS DANGER FROM FREEZING, THEN TESTS MAY BE MADE WITH AIR. WOODEN PLUGS ARE NOT TO BE USED IN MAKING TESTS. STERILIZATION OF DOMESTIC WATER SYSTEM: A. BEFORE BEING PLACED IN SERVICE ALL WATER LINES SHALL BE CHLORINATED TO THE SATISFACTION OF THE A.W.W.A SPECIFICATIONS C601 -53T. SOIL WASTE AND VENT PIPING: A. SOIL WASTE PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE, BELL & SPIGOT TYPE AS REQUIRED. B. VENT PIPE SHALL BE SERVICE WEIGHT CAST IRON BELL & SPIGOT TYPE AS REQUIRED PER LOCAL CODE. INSULATE —ALL LINES (ABOVE CEILING /IN WALLS INCLUDED): A. INSULATION ON COLD WATER, HOT WATER, CONDENSATE LINES, ETC., SHALL BE ARMAFLEX 11, OR APPROVED EQUAL, WITH THICKNESS AS REQUIRED. MINIMUM THICKNESS IS 1/2" INCH. B. INSULATION ON ROOF DRAINS AND ROOF DRAIN LEADERS SHALL BE FIBERGLASS WITH MULTI — PURPOSE WRAPPING. SUBSTITUTIONS: A. SUBSTITUTIONS WILL BE CONSIDERED FOR "OR EQUAL" BUT MUST BE APPROVED IN WRITING, BY OWNER, ARCHITECT OR ENGINEER, PRIOR TO INSTALLATION. B. IF, AFTER PLANS ARE COMPLETED, AUTHORITIES RULE THAT HANDICAPPED RESTROOM IS REQUIRED, BUT NOT SHOWN, USE AMERICAN STANDARD 'CADET —HI" WATER CLOSETS AND SET LAVATORY AT PROPER HEIGHT WITH LEVER HANDLES. (VERIFY ALL FINAL EQUIPMENT SPECS WITH PLUMBING DRAWING). WATER PIPING: A. WATER PIPING UNDER FLOOR SHALL BE TYPE "K" SOFT COPPER WITH SILVER SOLDER JOINTS. B. WATER PIPING ABOVE FLOOR SHALL BE TYPE "L" HARD DRAWN COPPER WITH LEAD FREE SOLDER JOINTS. CODE � WED FOR COMPLIANCE OMPLIAN APPOtlVED NOV 1 e 2010 City ot Tukwila BUILDING DIVISION REC6VE�D CITYOFTIU RA OCT 252010 PERMIT CENTER DuNHann Dunham Associates, Inc. 50 South Sixth Street 1 Suite 1100 inneap_lie, !Minnesota 55402- 15-40 P ONE 612.485.7550 ir=ax.612;485.7551 vine, duriharnerrg.com mechanical + electrical consulting engineering MBA Architects, Inc. 3823 Creekside Lane Holmen, WI. 54636 608 - 785 -2760 FAX: 608 - 785 -2750 E —mail: officeOmba— architects.com DEVELOPER'S SPACE NO. SUITE #108 CLIENT'S STORE NUMBER WA -11 SEE'S CANDIES SOUTHCENTER SQUARE 17100 SOUTHCENTER PKY. TUKWILA, WA 98188 9 1 SEE'S CANDIES 400 ALLAN STREET DALY CITY, CA., 94014 PH: 415/ 405 -7965 FAX: 415/ 586 -8557 TIM KIRCHER CLIENT CONTACT (415) 405 -7965 Tim R. Benson ARCHITECT'S PROJECT MANAGER 608/ 785 -2760 date client c contractor' vendor comments REVIEW 10/07/10 O BID / PERMR 10/13/10 OOOOO drawn by: DS checked by: GS THIS SHEET CONTAINS: SPECIFICATIONS PLUMBING WORK M3 ARCHITECT'S COMMISSION NUMBER 10- 725.069