HomeMy WebLinkAboutPermit PG10-153 - REISCHLING PRESSREISCHLING PRESS INC
3325 S 116 ST
PG1O-153
City ofkukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 0923049068
Address: 3325 S 116 ST TUKW
Project Name: REISCHLING PRESS INC
PLUMBING /GAS PIPING PERMIT
Permit Number: PG10 -153
Issue Date: 11/18/2010
Permit Expires On: 05/17/2011
Owner:
Name: RREEF AMERICA REIT II
Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261
Contact Person:
Name: MICHAEL ATWOOD
Address: 9630 153 AV NE , REDMOND WA 98052
Email: MATWOOD@MERITMECHANICAL.COM
Phone: 425- 883 -9224
Contractor:
Name: MERIT MECHANICAL INC. Phone: 425 883 -9224
Address: PO BOX 2109 , REDMOND, WA 98052
Contractor License No: MERITMI163CM Expiration Date: 06/01/2011
DESCRIPTION OF WORK:
INSTALL NEW 1" SUPPLY LINE TO GENERATOR (GENERATOR BY OTHERS).
Value of Plumbing /Gas Piping: $3,985.00 Uniform Plumbing Code Edition: 2009
Fees Collected: $120.75 International Fuel Gas Code Edition: 2009
Permit Center Authorized Signature:
LIst
Date: t1-le-to
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions
on the back of this permit.
Signature: i ti Date: 11 I/ r tzt7lb!
Print Name: KO4 E c
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG 10 -153 Printed: 11 -18 -2010
PERMIT CONDITIONS
Permit No. PG 10 -153
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: UPC -4/10
PG10 -153 Printed: 11 -18 -2010
CITY OF TUKKIDI
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /www. ci. tukwila. wa. us
Plumbing/Gas Permit No. I D- (S 3
Project No. V10-- I S 7
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 3325 S. 116th St.
Tenant Name: Reishling Press Inc
King Co Assessor's Tax No.: mi3Oy - yokA
Suite Number: 161 Floor:
New Tenant: ❑ Yes ❑ .. No
Property Owners Name: Rreef America Reit II
Mailing Address:
City
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: Michael Atwood
Mailing Address:
9630 153rd Ave NE
E -Mail Address: matwood @meritmechanical.com
Day Telephone:
Redmond
City
Fax Number:
(425) 883 -9224
WA
State
(425) 867 -0962
98052
Zip
PLUMBING I GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
Merit Mechanical, Inc
9630 153rd Ave NE
Same As Above
Redmond
City
Day Telephone:
Fax Number:
WA
State
98052
Zip
Expiration Date:
ARCHITECT OF RECORD — All plans must be stamped by Architect of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
ENGINEER OF RECORD - All plans must be stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
1-1: \ApplicationsTorms-Applications On Line \2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc
Revised: 7 -2010
bb
Page I of 2
Valuation of Project (contractor's bid pr. $ 3985.00
Scope of Work (please provide detailed 1 ormation): Install new 1" supply line to geator (Generator by Others)
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:'
Qty
Fixture Type:.
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and /or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
1.b
PERMIT -- APPLICATION NOTES
Value of Construction — In all cases, a value of constntction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR A THORIZED AGEN
Signature:
Print Name:
Michael Atwood
Date:
ii/Z /410
1ro-i° 410
Day Telephone: 425 - 883 -9224
Mailing Address: 9630 153rd Ave NE Redmond WA 98052
City
State
Zip
Date Application Accepted: If _1_
Date Application Expires: 5
Staff Initials:
11:\Applications\Fomu- Applications On Line \2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Applicaiiun.duc
Iteviscd: 7 -2010
bh
Page 2 of 2
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
RECEIPT
Parcel No.: 0923049068 Permit Number: PG10 -153
Address: 3325 S 116 ST TUKW Status: PENDING
Suite No: Applied Date: 11/02/2010
Applicant: REISCHLING PRESS INC Issue Date:
Receipt No.: R10 -02210
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $120.75
Payment Date: 11/02/2010 11:39 AM
Balance: $0.00
MERIT MECHANICAL INC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 24351 120.75
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
GAS - NONRES
PLAN CHECK - NONRES
000.322.103.00.00 96.60
000.345.830 24.15
Total: $120.75
doc: Receiot -06 Printed: 11 -02 -2010
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
rc 16 -l53
PERMIT NO. r)
CITY OF TUKWILA BUILDING DIVISION •f
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Projec i
.e2 S�\
`%
e(PS,s
Type of Inspection:
�i /v 10
c 0 Al S
Addreu:
I
i_Z,.,
Date Called:
Special Instructions:
Date Wanted:
` a•m.
P.m.
Requester:
Phone No:
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS: �AA -�-- -- ��,
n -Q% :'mil 4 t C,D n
Sri' /i a il cG4 1 .A 4
6 e.A.ef-A>-,i- Fo/ 2-1 &J . gf" uC
Inspecto(:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTIO NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING, DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Type
...of
ovi I— io J °-6,71S
Address: Date Called:
335 S t I(/ S
Special Instructions: Date Wanted:
L,2 —Z— IO
Requester:
Phone No:
y2.S_LiLPS —lyF.>„7----
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
S .5 _ f
d ✓ /
A Sil l ( iIte-A BU (L45 ;\,\
r
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
S .5 _ f
d ✓ /
A Sil l ( iIte-A BU (L45 ;\,\
r
. -
6-eAr9r r .
r D 1U h 6
F o -
I
REINSPECTION FEE REQUIRED. Prior to next. inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Insp actor:
Date:
I t -I, 1 ■
- - _
, -- --- - - . + t
- 4 . -,-
• ._- 4 -4 . t , ,
. • 1 1 I
I I 1
■ 1 -- 1
IF
, 1 1
4__ 1. ,_ „ _+ ,_ -t- t--
II ', ' I I
• , , , ,-- * r "
!III I I 4 L IIII1
+ + t .- or .„ —,. -tea" ••••■•
• - • : • •- •- - 'I.- i.- '
I 1 " 1 I ' Pi at. review
,
III, L I I I i I I
1 ". J t■--**Tat
1 I I rt 1 1
T; 1
1 '
Li-
1 1 ;1-• 17 , ._,
• __ r• t
r ril "s ,___
, . ! ! , , A t_. 1
1 b.
___ * 4- 44, i-
_ [ • 4 .I- -
1 I
t
t —
I
- '4 4-
; _t
171,, t
• ; L
I I ! I rH
le I
-I-- -
„
•
fieta C 4-RecIPt -ktec
1--
3; ; - ;•
I
: 6 6:6, ,6, ,6, ..114
14166. 'el\Arw.
-Jr
t-44
f'■■ I 1-1
•- I
?!k-4- 4 -4
„ I I
I,
:1,11
t
t -
1 + -
7-1 r -1 ---t --t t--t-- s-
s t
.i. ,I
t_ ! i t
, .„.. ,
! I ! !
! ! !
-1- ---
- L----,--
_,_ 4,. •
• , 1-- • T -' I .-- r
! _t__ —.
! ._
' I
L , :- } ---
, L '- •_1_, LL_ I IL
I „
. ,
4- r
'7-
[ 11_4 —
• E,[_f5ARATiP
REQUiREDR)
-Lets
-ialturnbing
t
tss
-r r-
, , I ,
, -t-
, 4- ,
s!,
1-- -4-
:
—'r-
_t___ l I , 4• -,
L •,.k !.
1 ,
1_ ,
i
I , ,
1
___I _ _r
1
I..
_.L.
! !
• ,
' I •
I
- 1
rElr
grp
Cri tpt-ti
-4- —I.--
1
I I
i r-
I ' I
"L'
-r- -r
,
OE COMPLIANCE
UV C4110-7 -;
-
-
Ii'
_ L
NG 1,
- -P
z;:,3' ®/
01114a1 ,•!4?
5114 144
- 1144614,204411 -I aMoli
i
vmot
9l1tfofrS ,9(10/7 17041 S> 0:20
Model: 60REZG
KOHLER.POWER SYSTEMS
190 -600 V
Gas
O 9001
� MOHLER.
® POWER SYSTEMS
NATIONALLY REGISTERED
Ratings Range
Standby: kW
kVA
60 Hz 50 Hz
49 -64 40 -53 • The generator set accepts rated load in one step.
49 -80 40 -66
Standard Features
• Kohler Co. provides one - source responsibility for the
generating system and accessories.
• The generator set and its components are prototype- tested,
factory - built, and production- tested.
• The 60 Hz generator set offers a UL 2200 listing.
Generator Set Ratings
• The 60 Hz generator set meets NFPA 110, Level 1, when
equipped with the necessary accessories and installed per
NFPA standards.
• The 60 Hz generator set engine is certified by the
Environmental Protection Agency (EPA) to conform to the
New Source Performance Standard (NSPS) for stationary
spark - ignited emissions.
• A one -year limited warranty covers all systems and
components. Two- and five -year extended warranties are
also available.
Natural Gas LP Gas
130 °C Rise 130 °C Rise
Standby Rating Standby Rating
Atternat Volta e Ph Hz kW/kVA Amps kW /kVA Amps
120/208 3 60 60/75 208 60/75 208
12 /1220 3 60 60/75 197 61/76 200
120/240 3 60 60/75 180 60/75 180
120/240 1 60 49/49 204 49/49 204
139/240 3 60 60/75 180 62/78 186
220/380 3 60 55/69 104 55/69 104
277/480 3 60 60/75 90 62/78 93
347/600 3 60 60/75 72 62/78 75
110/190 3 50 48/60 182 50/62 188
115/200 3 50 46/58 187 46/58 167
110/220 1 50 40/40 182 40/40 182
110/220 3 50 48/60 157 50/62 163
220/380- . 3 50 48/60 91 50/62 94
230/400 3 50 46/58 84 46/58 84
120/208 3 60 60/75 208 63/79 219
127/220 3 60 60/75 197 64/80 210
120/240 3 60 60/75 180 63/79 189
120/240 1 60 57/57 238 59/59 246
139/240 3 60 60/75 180 64/80 192
220/380 3 60 60/75 114 63/79 120
277/480 3 60 60/75 90 64/80 96
4S7 347/600 3 60 60/75 72 64/80 77
110/190 3 50 48/60 182 50/62 188
115/200 3 50 49/61 176 53/66 191
120/208 3 50 49/61 169 53/66 183
110/220 1 50 45/45 205 47/47 214
110/220 3 50 48/60 157 53/66 173
220/380 3 50 48/60 91 53/66 100
230/400 3 50 48/60 87 53/66 95
240/416 3 50 49/61 85 53/66 92
4Q10 120/240 1 60 55/55 229 55/55 229
110/220 1 50 46/46 209 50/50 227
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 1 R 2010
City of Tukwila
BUILDING DIVISION
RECEIVED
NOV 02 2010
PERMIT CENTER
4V9 120/240 1 60 60/60 250 60/60 250
110/220 1 50 47/47 214 51/51 232
RATINGS: All three.phase units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source.
The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance With 150- 304611, BS 5514, AS 2789, and
DIN 6271. Prime Power Ratings: Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A.
10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO- 8528/1, overload power in accordance with I50- 3046/1, 85 5514, AS 2789, and DIN 6271. For limited running
time and base load ratings, consult the factory. Obtain the technical information bulletin (TIB -101) on ratings guidelines for the complete ratings definitions. The generator set manufacturer reserves the
right to change the design or specifications without notice and without any obligation or liability whatsoever. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 1.3% per 100 m (328 11.) elevation
above 200 m (656 ft.). Temperature: Derate 3.0% per 10 °C (18 °F) temperature above 25'C (77 °F). For dual fuel engines, use the natural gas ratings for both the primary and secondary fuels.
G4 -132 (60REZG) 4/10d
Alternator Specifications
Specifications
Alternator
Manufacturer
Type
Exciter type
Leads: quantity, type
4P8, 4S7
4Q10, 4V9
Voltage regulator
Insulation:
Material
Temperature rise
Bearing: quantity, type
Coupling
Amortisseur windings
Voltage regulation, no -load to full -load
Decision -Maker 550 controller (with
0.5% drift due to temp. variation)
Decision -Maker 3000 controller
One -step load acceptance
Unbalanced load capability
Peak motor starting kVA:
480 V, 380 V 4P8 (12 lead)
480 V, 380 V 4S7 (12 lead)
240 V, 220 V 4Q10 (4 lead)
240 V, 220 V 4V9 (4 lead)
Engine
Kohler
4 -Pole, Rotating -Field
Brushless, Permanent -
Magnet
12, Reconnectable
4, 110 - 120/220 -240
Solid State, Volts /Hz
NEMA MG1
Class H
130 °C, Standby
1, Sealed
Flexible Disc
Full
3 -Phase Sensing, ±0.25%
3 -Phase Sensing, ±0.5%
100% of Rating
100% of Rated Standby
Current
(35% dip for voltages below)
212 (60 Hz), 145 (50 Hz)
270 (60 Hz), 190 (50 Hz)
155 (60 Hz), 133 (50 Hz)
246 (60 Hz), 213 (50 Hz)
• NEMA MG1, IEEE, and ANSI standards compliance for
temperature rise and motor starting.
• Sustained short- circuit current of up to 300% of the rated
current for up to 10 seconds.
• Sustained short- circuit current enabling downstream circuit
breakers to trip without collapsing the alternator field.
• Self- ventilated and dripproof construction.
• Vacuum - impregnated windings with fungus- resistant epoxy
varnish for dependability and long life.
• Superior voltage waveform from a two- thirds pitch stator and
skewed rotor.
• Fast- Response' II brushless alternator with brushless
exciter for excellent load response.
Application Data
Engine Electrical
Engine Specifications
Manufacturer
Engine: model, type
60 Hz 50 Hz
Cylinder arrangement
Displacement, L (cu. in.)
Bore and stroke, mm (in.)
Compression ratio
Piston speed, m /min. (ft. /min,)
Main bearings: quantity, type
Rated rpm
Max. power at rated rpm, kW (HP)
Cylinder head material
Piston type and material
Crankshaft material
Valve (exhaust) material
Governor type
Frequency regulation, no -load to full -load
Frequency regulation, steady state
Frequency
Air cleaner type, all models
Exhaust
General Motors
Industrial Powertrain
Vortec 5.7 L, 4 -Cycle
Natural Aspiration
V -8
5.7 (350)
101.6 x 88.4 (4.00 x 3.48)
. 9.1:1
318 (1044) 265 (870)
5, M400 Copper Lead
1800 1500
78.3 (105) 65.6 (88)
Cast Iron
High Silicon Aluminum
Nodular Iron
Forged Steel
Electronic
lsochronous
x0.5%
Fixed
Dry
REVIEWED D FOR
CODE COMPLIANCE.
APPonlvED
NuV 1 R 2010
City of Tukwila
BUILDING DIVISION
Engine Electrical System
60 Hz 50 Hz
Ignition system
Battery charging alternator:
Ground (negative /positive)
Volts (DC)
Ampere rating
Starter motor rated voltage (DC)
Battery, recommended cold cranking
amps (CCA):
Qty., rating for -18 °C (0 °F)
Battery voltage (DC)
Fuel
Electronic
Negative
12
70
12
1, 630
12
4+ Fuel System
Exhaust System
60 Hz 50 Hz
Exhaust manifold type
Exhaust flow at rated kW, m3 /min. (cfm)
Exhaust temperature at rated kW, dry
exhaust, °C ( °F)
Maximum allowable back pressure,
kPa (in. Hg)
Exhaust outlet size at engine hookup,
mm (in.)
Dry
16.4 (580) 13.6 (480)
649 (1200)
10.2 (3.0)
76 (3.0) OD
Fuel type
60 Hz 50 Hz
Fuel supply line inlet
Natural gas /LPG fuel supply pressure,
measured at the generator set fuel inlet
downstream of any fuel system
equipment accessories, kPa (in. H20)
LP Gas, Natural Gas, or
Dual Fuel
1 NPTF
1.74 -2.74 (7 -11)
Fuel Composition Limits *
Nat. Gas LP Gas
Methane, % by volume
Ethane, % by volume
Propane, % by volume
Propene, % by volume
C4 and higher, % by volume
Sulfur, ppm mass
Lower heating value,
kJ /m3 (Btu/f13), min.
90 min.
4.0 max. —
1.0 max. 85 min.
0.1 max. 5.0 max.
0.3 max. 2.5 max.
25 max.
26.6 (890) 67.5 (2260)
* Fuels with other compositions may be acceptable. If your fuel is
outside the listed specifications, contact your lon i} vEr)
further analysis and advice. ((�\,,//''
G4.132 (60REZG) 4 /10d
NOV 02 2010
PERMIT CENTER
Application Data
Lubrication
Lubricating System 60 Hz 50 Hz
Type Full Pressure
Oil pan capacity, L (qt.) 4.7 (5.0)
Oil pan capacity with filter, L (qt.) 6.2 (6.5)
Oil filter: quantity, type .1, Cartridge
Cooling
Radiator System
60 Hz 50 Hz
Ambient temperature, °C ( °F) *
Engine jacket water capacity, L (gal.)
Radiator system capacity, including
engine, L (gal.)
Engine jacket water flow, Lpm (gpm)
Heat rejected to cooling water at rated
kW, dry exhaust, kW (Btu /min.)
Water pump type
Fan diameter, including blades, mm (in.)
Fan, kWm (HP)
Max. restriction of cooling air, intake and
discharge side of radiator, kPa (in. H2O)
50 (122)
6.8 (1.8)
20.8 (5.5)
117.3 (31) 98.4 (26)
54.8 (3120) 45.7 (2600)
Centrifugal
533 (21)
4.5 (6.0) 2.6 (3.5)
0.125 (0.5)
* Enclosure with enclosed silencer reduces ambient temperature
capability by 5 °C (9 °F).
Operation Requirements
Air Requirements
Radiator - cooled cooling air,
m3 /min. (scfm)t
Combustion air, m3 /min. (cfm)
Heat rejected to ambient air:
Engine, kW (Btu /min.)
Alternator, kW (Btu /min.)
t Air density = 1.20 kg /m3 (0.075 Ibm /ft3)
60 Hz 50 Hz
170 (6000) 136 (4800)
5.2 (185) 4.4 (155)
30.9 (1760) 26.5 (1510)
7.7 (440) 6.9 (390)
Fuel Consumption
60 Hz 50 Hz
Natural Gas, m3 /hr. (cfh) at % load-
100%
75%
50%
25%
LP Gas, m3 /hr. (cfh) at % load
100%
75%
50%
25%
Standby Ratings
22.4 (790)
19.4 (685)
14.7 (520)
9.9 (350)
18.1 (640)
15.6 (550)
11.8 (415)
7.8 (275)
Standby Ratings
9.3 (530)
7.1 (250)
5.4 (190)
3.8 (135)
7.9 (280)
6.2 (220)
4.7 (165)
3.1 (110)
Fuel consumption is based on 1015 Btu /standard cu ft natural gas.
LP vapor conversion factors:
8.58 ft.3 = 1 lb.
0.535 m3 = 1 kg.
36.39 ft.3 = 1 gal.
Controllers
Decision - Makerl" 550 Controller
Audiovisual annunciation with NFPA 110 Level 1 capability.
Programmable microprocessor logic and digital display features.
Alternator safeguard circuit protection.
12- or 24 -volt engine electrical system capability.
Remote start, remote annunciation, and remote communication options.
Refer to G6 -46 for additional controller features and accessories.
Decision - Maker 3000 Controller
Provides advanced control, system monitoring, and system diagnostics
for optimum performance and compatibility.
• Digital display and menu control provide easy local data access
• Measurements are selectable in metric or English units
• Scrolling display shows critical data at a glance
• Integrated hybrid voltage regulator with x0.5% regulation
• Built -in alternator thermal overload protection
• NFPA 110 Level 1 capability
Refer to G6 -100 for additional controller features and accessories.
REVIEWED FOR
CODE COMPLIANCE
,APDDflVED
NuV 1 2010
City of Tukwila
BUILDING DIVICION
G4 -132 (60REZG) 4/10d
RECEIVED
NOV 02 2010
PERMIT CENTER
KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-565-3381, Fax 920 - 459 -1646
For the nearest sales and service outlet in the
US and Canada, phone 1- 800 - 544 -2444
KohlerPower.com
Kohler Power Systems
Asia Pacific Headquarters
7 Jurong Pier Road
Singapore 619159
Phone (65) 6264 -6422, Fax (65) 6264 -6455
Additional Standard Features
• Alternator Protection
• Battery Rack and Cables
• Electronic, lsochronous Governor
• Gas Fuel System (includes fuel mixer, electronic secondary gas
regulator, gas solenoid valve, and flexible fuel line between the
engine and the skid - mounted fuel system components)
• Integral Vibration Isolation
• Local Emergency Stop
• Oil Drain Extension
• Operation and Installation Literature
Available Options
Approvals and Listings
j CSA Approval
XI IBC Seismic Certification
• UL 2200 Listing
Enclosed Unit
El Sound Enclosure (with enclosed critical silencer)
J Weather Enclosure (with enclosed critical silencer)
Open Unit
J Exhaust Silencer, Critical (kit: PA- 352663)
Flexible Exhaust Connector, Stainless Steel
Fuel System
Dual Fuel NG /LPG (automatic changeover)
Flexible Fuel Line
(required when the generator set skid is spring mounted)
j Gas Filter
Xi Secondary Gas Solenoid Valve
Controller
Common Fault Relay
Communication Products and PC Software (550 controller only)
Customer Connection (550 controller only)
Dry Contact (isolated alarm) (550 controller only)
Input /Output Module (3000 controller only)
Remote Annunciator Panel
Remote Audiovisual Alarm Panel (550 controller only)
Remote Emergency Stop
Run Relay
Cooling System
Ig) Block Heater
[recommended for ambient temperatures below 10 °C (50 °F)]
Electrical System
Alternator Strip Heater
Battery
Battery Charger, Equalize /Float Type
Battery Heater
Line Circuit Breaker (NEMA1 enclosure)
Line Circuit Breaker wit nt Trip _ {I NIvj�,j ���gJ�
C ORDE E COMPLIANCE
W E �
U
AQparlVED
PVijV 1 F ii110
e LI LI LI Li LI Ll LI
LI LI 01 -e LI
City of Tukwila
Miscellaneous
)g) Air Cleaner Restrictor Indicator
Ki Engine Fluids (oil and coolant) Added
$) Rated Power Factor Testing
it Rodent Guards
Literature
XI General Maintenance 3 Copies
▪ NFPA 110
.J Overhaul
J Production
Warranty
2 -Year Basic
2 -Year Prime
5 -Year Basic
5 -Year Comprehensive
J
J
J
LI LI Ll Li U LI LI LI
Other Options
Dimensions and Weights
Overall Size, Lx W x H, mm (in.):
Wide Skid 2200 x 1040x 1172 (86.6 x 40.9 x 46.1)
Narrow Skid 2200 x 864 x 1172 (86.6 x 34.0 x 46.1)
Weight (radiator model), wet, kg (lb.): 755 (1665)
1
H
r—
I W
NOTE: This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.
DISTRIBUTED BY:
RECEIV C
NOV 0 2 2010
PERMIT CENT =F
2009, 2010 by Kohler Co. All rights reserved.
BUILDING DIVISIOR4-132 (60REZG) 4 /10d
*
OEWY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG10 -153 DATE: 11 -02 -10
PROJECT NAME: REISCHLING PRESS INC
SITE ADDRESS: 3325 S 116 ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
piwc
&ding'lvision II Fire Prevention
Public Works
Structural
Planning Division
n Permit Coordinator
n
S
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 11-04-10
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required
❑ No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 12-02-10
Approved Approved with Conditions tg Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name MERIT MECHANICAL INC UBI No. 600517946
Phone 4258839224 Status Active
Address Po Box 2109 License No. MERITMI163CM
Suite /Apt. License Type Construction Contractor
City Redmond Effective Date 2/14/1984
State WA Expiration Date 6/1/2011
Zip 980732109 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
AUTOMMC044QH
AUTOMATED MECH
CONTROLS INC
Construction
Contractor
General
Unused
11/8/1996
6/1/2010
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
KIRKWOOD, RODERICK V
President
02/14/1984
Bond Amount
KIRKWOOD, JOAN M
Secretary
02/27/2006
08358695
FRICKBERG, WILLIAM MICHAEL
Vice President
02/27/2006
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
10
FIDELITY Et DEPOSIT
CO OF MD
08358695
02/01/2010
Until Cancelled
$12,000.00
01 /20 /2010
9
ARCH INS CO
SU1041124
02/01/2009
Until Cancelled
02/01/2010
$12,000.0001
/12/2009
8
TRAVELERS CAS &
SURETY CO
081S103546895BCM
07/22/2001
Until Cancelled
02/01/2009
$12,000.00
03/07/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
26
LEXINGTON INS
014180670
11/01/2010
11/01/2011
$2,000,000.00
10/29/2010
25
LEXINGTON INS
CO
049159165
11/01/2009
11/01/2010
$2,000,000.0011
/02/2009
24
CO INGTON INS
004052434
11/01/2008
11/01/2009
$2,000,000.00
11/04/2008
23
ACE AMERICAN
INS
HDOG23734941
03/03/2008
03/03/2009
$2,000,000.00
03/10/2008
22
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2007
11/01/2008
$1,000,000.00
10/31/2007
21
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2005
11/01/2007
$1,000,000.00
10/18/2006
20
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2004
11/01/2005
$1,000,000.00
11/01/2004
https://fortress.wa.gov/lni/bbip/Print.aspx