Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG10-159 - TARGET
TARGET 301 STRANDER BL PG1O-159 City akukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Project Name: TARGET PLUMBING /GAS PIPING PERMIT Permit Number: PG10 -159 Issue Date: 05/06/2011 Permit Expires On: 11/02/2011 Owner: Name: TARGET CORPORATION T 0627 Address: C/O PROPERTY TAX/TPN 0950 , PO BOX 9456 55440 Contact Person: Name: DAVID CONTRERAS Address: 601 SW 2 AV - SUITE 1200 , PORTLAND OR 97204 Email: DAVID.CONTRERAS @MULVANNYG2.COM Contractor: Name: SKANSKA USA BUILDING INC Address: 1633 LITTLETON ROAD , PARSIPPANY NJ 07054 Contractor License No: SKANSUB985RT Phone: 971- 998 -1451 Phone: 973 - 753 -3500 Expiration Date: 01/12/2013 DESCRIPTION OF WORK: INSTALL OVERHEAD AND UNDERFLOOR PLUMBING LINES Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: $47,725.00 $360.94 PUGET SOUND ENERGY Uniform Plumbing Code Edition: International Fuel Gas Code Edition: 2009 2009 111 / t ' 1 Permit Center Authorized Signature: _ / �i / Dat I hereby certify that I have read and examined t s perm' / and kno the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this pe it. r Signature: Print Name: Mi LIa e.1 Date: S-7(0 /1 I This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG10 -159 Printed: 05 -06 -2011 PERMIT CONDITIONS Permit No. PG10 -159 1: ** *PLUMBING AND GAS PIPING * ** M 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG10 -159 Printed: 05 -06 -2011 J CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Building Permit No. DID - 3 Mechanical Permit No. VI [0 ( to UJ Plumbing /Gas Permit No. 'k)(9 10— IS I Public Works Permit No. Project No. (For of/ice use only) Applications and plans mast be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 301 Strander Blvd - Tukwila, WA 98188 Tenant Name: Target Store T -0627 King Co Assessor's Tax No.: 2623049005 Suite Number: Floor: New Tenant: ❑ Yes m .. No Property Owners Name: Target Corporation Mailing Address: 1000 Nicollet Mall Minneapolis City I1 State 55403 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: David Contreras - MulvannyG2 Architecture Mailing Address: 601 SW 2nd Ave., Suite 1200 Day Telephone: (971) 998 -1451 Portland OR 97204 E -Mail Address: david.contreras @mulvannyg2.com City State Fax Number: (971) 217 -0122 Zip GENERAL CONTRACTOR INFORMATION — (Contractor information for Mechanical(pg il) for Plumbing and Gas Piping (pg 5)) Company Name: Skanska USA Building, Inc. Mailing Address: 221 Yale Ave., North #400 Contact Person: TBD E -Mail Address: Contractor Registration Number: Seattle City Day Telephone: Fax Number: Expiration Date: WA 98109 State Zip ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: MulvannyG2 Architecture Mailing Address: 601 SW 2nd Ave., Suite 1200 Contact Person: Brian R. Fleener Portland OR 97204 E -Mail Address: City Day Telephone: Fax Number: State (503) 223 -8030 Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: Contact Person: Myers Houghton & Partners 4500 E Pacific Coast Hwy., Ste 100 Garry D. Myers E -Mail Address: HAApplicationa \Font» - Applications On LineV20I0 Applicmioos\ -21110 - Permit Application.dnc Revised: 7- 2010 hh Long Beach CA City State Day Telephone: (562) 985 -3200 90804\ Zip Fax Number: Page 1 of 6 BUILDING PERMIT INFORMAT — 206 -431 -3670 Valuation of Project (contractor's bid price): $ a32i J .2`:afG"' Existing Building Valuation: $ Scope of Work (please provide detailed information): Installation of walk -in coolers /freezer in stock room. Part of the project will include decor upgrades to match the revised store layout. Will there be new rack storage? m Yes 0.. No If yes, a separate permit and plan submittal will be required. Ge A.-0* 5g52, SFS? Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (ar *For an Accessory dwelling, pro Lot Area (sq ft): of the foundation of all structures, plus any de the following: Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documen Lori that shows that the principal owner lives in one of the dwe ngs as his or her primary residence. Number of Parking Sta . Provided: Standard: Compact: Handicap: over 18 inches and overhangs greater than 18 inches) Will there be a than, in use? ❑ Yes m No If "yes ", exp . n: FIRE PROT r TION /HAZARDOUS MATERIALS: O... .Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there e storage or use of flammable, combustible or hazardous materials in the building? L7 Yes ❑ No If " es', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. —012-A4.4.) uti SHEC S Fgll .4-4") t -92.1. SEP IC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:b\pplicatiom \Forms Applications On Line \20111 Applications \7 -2010 - Permit Applieation.doc Revised: 7- 20111 bh Page 2 of 6 xisting Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I" Floor ' 13,588 10,436 0 0 2 -N M 2 "d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage . Attached Carport Detached,Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (ar *For an Accessory dwelling, pro Lot Area (sq ft): of the foundation of all structures, plus any de the following: Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documen Lori that shows that the principal owner lives in one of the dwe ngs as his or her primary residence. Number of Parking Sta . Provided: Standard: Compact: Handicap: over 18 inches and overhangs greater than 18 inches) Will there be a than, in use? ❑ Yes m No If "yes ", exp . n: FIRE PROT r TION /HAZARDOUS MATERIALS: O... .Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there e storage or use of flammable, combustible or hazardous materials in the building? L7 Yes ❑ No If " es', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. —012-A4.4.) uti SHEC S Fgll .4-4") t -92.1. SEP IC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:b\pplicatiom \Forms Applications On Line \20111 Applications \7 -2010 - Permit Applieation.doc Revised: 7- 20111 bh Page 2 of 6 -r • PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: TBD Mailing Address: City Statc Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 47,725 Valuation of Gas Piping work (contractor's bid price): $ Sco pe of Work (p l ease provide detailed i nform tion): '^7 1 /id� / ) 1 /.i' - <7 � Z:-/' : eel (—)7:-X--- / n3. Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: • Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower 0 Bidet Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor Drain 2 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 3 Sinks 3 Urinals 0 Water Closet 0 Building sewer and each trailer park sewer 0 Rain water system — per drain (inside building) 0 Water heater and /or vent industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors 0 Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) 0 Grease interceptor for commercial kitchen ( >750 gallon capacity) 0 Repair or alteration of water piping and /or water treatment equipment 5 Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas 0 Each additional medical gas inlets /outlets greater than 5 0 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller 1 Backtlow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices 0 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H ?Applientions\Forms- Applications On Line'20111 Applications N7-2010 - Permit Application.doc Revised: 7 -2010 bh Page 5 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THiS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THiS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ► > C. C_.JJ Print Name: David Contreras Mailing Address: 601 SW 2nd Ave., Suite 1200 Date: //// 7/ /O Day Telephone: (971) 998-1451 Portland City OR Slate 97204 Zip Date Application Accepted: Date Application Expires: 5 (6/-1 1 Staff Initials: 14c H:Mpplications \Forms-Applications On Line\2010 Applications \7 -2010 - Permit Applicalion.doc Revised: 7 -2010 bh Page 6 of 6 o CCity of Tukwila 908 • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: PG10 -159 Status: APPROVED Applied Date: 11/19/2010 Issue Date: Receipt No.: R11 -00909 Initials: TLS User ID: 1670 Payment Amount: $288.75 Payment Date: 05/06/2011 01:54 PM Balance: $0.00 Payee: SKANSKA USA BUILDING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 430619 288.75 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 288.75 Total: $288.75 doc: Receiot -06 Printed: 05 -06 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049005 Permit Number: PG 10 -159 Address: 301 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 11/19/2010 Applicant: TARGET Issue Date: Receipt No.: R10 -02361 Initials: User ID: Payee: WER 1655 Payment Amount: $72.19 Payment Date: 11/19/2010 03:15 PM Balance: $288.75 TARGET TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1298004 72.19 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 72.19 Total: $72.19 doc: Receiot -06 Printed: 11 -19 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Address: - - 30 l ST (1..Ut4b P Date Called: �.- Special Instructions: Date Wanted: 7_2?-t( 2.0 Ca.m; p.m. Requester: Phone No: 154Approved per applicable codes. Corrections required prior to approval. COMMENTS: rape or: Date: y- rte,, , r _ Lb - I ❑ 15 .00 REINSPECTIU 4 FEE REQUIRRF�D. Prior o inspection, fee must be (d at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �v PrQ'ect: ____,_- Type of Inspection: F'. ,t_. Pc...., Q.1-1. 4 i�/� Address: 30( s'N'A.J A L Date Called: ligr'h- .-a^'t Special Instructions: Date Wanted:7 — 8-- ( .n3- P.m. Requester: Phone No: �+ c0 -- 8 .4 -1 14x3 ElApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: p. A . a.) P"?' j,:v Cp (1.7/44 r/ 14° f,r- s4/ : s ligr'h- .-a^'t /r/,4✓'4 - /34.0 k r Arx./ v ,,,,/;7 ',S /jprr LS +- .")✓ I Inspector Date: ?- °- (./ n NSPECTION FEE RE9UIRED. Prior/next inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project :: q /j `V�.141<// Type of Inspection: 6,1- r) in IA( J /r.•- Address: I SV- ■oL1 3 ,) ,- Date Called: _._ _._ Special Instructions: Date Wanted: / t'-". / 1 3--(/ Cmi` P.m. Requester: - Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 44A p TCrs f--� / U /ztfJ t; Th r\ It ti ;! Inspect F, � 11.) Luc' J Date: (043-/ ( / n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • INSPECTION. RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 PC10-Isg Project: —TA /? i . Type of Inspection: F-,iJ4L- p/tuwrt Address: 30 I s, R /A0gI - a -p liaJoc0 Date Called: Special Instructions: 050072 -0 1 Date Wanted: 6_3_.It Cafii? p.m. Requester: Phone No: v0(, -s52 ~4/775 Approved per applicable codes. aCorrections required prior to approval COMMENTS:?) . ?) \2d\ -w - a -p liaJoc0 n / Ip'1SPECTION FEE RQUIRED. Prior to nex inspection. fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: J,/ . . . - ; • INSPECTION RECORD Retain a copy vitith permit kol OIS INSPECTION NO. PERMIT NO. 3 CITY OF TUKWILA BUILDING DIVISION 12 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: —1—PPCe."..er Type Af Inspection: 14-(RUC,44,--i-Ni Address: r&) k ---1-0. Ft■J IZ:g. rz_ Date Called: . Special Instructions: Date Wanted: k oi-20-1 Ft Requester: Phone No: ,o ,--Gt.(---)L1.5-3 ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: flpb A al recto Date: 5 '4° R N PECTION FEE REQUIRED Prior to lext inspection. fee must be .1. at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. p INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION iR 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • Project: / 4/7 .7--- Type of Inspection: 6 /24/4/0 (AM / kk Address: 30 / ...5-7-,?,1 .t/ /t. Date Called: Special Instructions: Date Wanted: a.m 5 — /7-- // p.m. Requester: Phone No: c:> 06-84/9 - )‘/ 3-3 ElApproved per applicable codes. Corrections required . prior to approval. COMMENTS: C ✓.n •4 LOA/ w,tsrt_ f14"4-1° fc%°. J i npector: Date ' 1 7 1 ! REI SECTION FEE REQUIREp. Prior to next inspection. fee must be. pai f 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION. RECORD Retain a copy with permit P6/0- /s5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670, Permit Inspection Request Line (206),431 -2451 Project: Ti R( % Type of Inspection: C/24) /.J.0 LJO /'c �C Address: 30 / S 77?4 t%Z)6.e Date Called: -L- — /490X -,-1 -_, of p b Special Instructions: Date Wanted: 5 — C / - // �mD P.m. Requester: .mod 1%L Phone No: c- 5.3- "732 --3 S 3d ElApproved per applicable codes. E Corrections required prior to approval. -1 COMMENTS; 94 J 4 .6 /0),Al ( -L- — /490X -,-1 -_, of p b -- aj9 fl /4/.�i 0- 1;A/'. J 4 .mod 1%L f p .1,1„m,s�7 / )' NSPECTION FEE REQUIREI id Jt 6300 Southcenter Blvd.. Date: o next inspection. fee must be 00. Call to schedule reinspection. 17 � 'F61°'-'159 // \ / Vacuum Plumbing Systems 13818 Oaks Avenue • Chino, CA 91710• USA Site Visit # 2 Date: 7 -11 -11 (800) 591-9920 •909- 902 -1141• Fax 909 - 902 -5041 Project: T-0627 Tukwila, WA Inspector: Ken Robinson System Checkout 1) Vacuum Center Unit: Y N Other a) Unit installed per AcornVac requirements & engineering drawings: b) Proper pump rotation verified: c) All piping materials are of acceptable grade & quality: d) Discharge lines installed per AcornVac requirements & engineering drawings: e) Unit leak rate within specifications: f) All water makeup lines connected: g) Pump overflow lines directed to floor drain: h) Proper service clearance provided around unit: i) All pump Controls set to AUTO: j) Unit connected to aux. power: k) Alarm outputs connected: I) Manager received OPS Manual Kim Nee ( SFT ) Print Receiving Mgr. Name See Comments Below 2) Lift Assemblies: Y N Other a) All extraction valves installed properly: b) All vacuum piping properly braced: c) All inline check valve installed on vacuum source line to controller: d) All check valves installed in overhead piping as required / specified: e) All accumulators installed properly: f) All controllers installed correctly: g) All vacuum tubing not subject to restriction: h) All sensor lines have no traps: See Comments Below ❑ 3) Overhead Piping Network: Y N Other a) All piping installed per engineering drawings & AcornVac requirements: b) System leak rate with in specification: c) All system overhead piping properly braced to resist shock & thrusting forces: d) All risers properly braced to resist shock & thrusting forces: e) All intersections of system piping enter from above: See Comments Below ❑ Visit Summary: Notes: 1j) Not at this time. Operational ® Unfinished ❑ 3 ® ❑ ❑ ® ❑ ❑ ® ❑ ❑ ® ❑ ❑ Z ❑ ❑ Deviations ❑ Warranty Activated El 13818 Oaks Avenue • Chino, CA 91710• USA Vacuum Plumbing Systems Date: 7/11/2011 Summary Comments General Observations: Outstanding Issues: 1j) Not at this time. Summary: (800) 591 -9920 • 909-902-1141 • Fax 909 - 902 -5041 Project: T -0627 Tukwila, WA Inspector: Ken Robinson ❑ System is not yet commissioned. Installation is incomplete at the time of this inspection. • System is commissioned and installed to plans and manufacturer's specifications. ❑ System is commissioned, but NOT installed to plans and manufacturer's specifications. This report is intended to provide assurance that the AcornVac vacuum system has been installed in compliance with AcornVac design criteria and contract documents. If, upon the last scheduled site visit, there are deficiencies yet to be corrected they will be noted on this report and the system will not be subject to standard AcornVac warrantee terms and conditions until corrections are made and verified by an authorized AcornVac factory or independent representative. It is the owner's final responsibility to enforce contractor compliance in making corrections to any noted deviation or incomplete installation. Should additional visit(s) or site inspection /visit be required, these can be provided upon purchase order request. Whenever possible, AcornVac will allow for verification of correction upon receipt of documented photos. Final determination will be at the discretion of AcornVac Inc. or by an authorized independent AcornVac representative. AcornVac does not assume responsibility for the following: assuring that basic plumbing practices and local codes are being adhered to ; for the integrity of piping connection, either PVC or copper; for any piping or piping connections that cannot be observed within walls, behind cases, etc; for obstructions or kinks in the sensor lines that were either not observable at the time our inspections, or caused at a later date; or for any installation work that took place subsequent to system start-up, or our last site visit. 4 \in1 600 Minkler Blvd, 'Tukwila, WA 98 1 as City of Tukwila — Public Works Maintenance Department 600 Minkler Blvd, Tukwila, WA 98188 Backflow Assembly Test Report Form Po.o -t59 NAME SERVICE ADDRESS 301 Strander Blvd CITY Tukwila ASSEMBLY LOCATION At riser CROSS -CONNECTION CONTROL FOR fire sprinklers SIZE Target #0627 ACCOUNT# METER # STATE Wa ZIP CODE 98188 8" MAKE Febco LINE PRESSURE AT TIME OF TEST? 140 MODEL 805YD NEW? ❑ TYPE DCVA EXISTING? Ejl INITIAL TEST RESULTS SN B7178 REPLACEMTN? ❑ TESTS AFTER REPAIR OR CLEANING RPBA PSI DROP ACROSS #1 CHECK VALVE PSID RELIEF VALVE OPENED PSID #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? Yes ❑ No ❑ PSI DROP ACROSS #1 CHECK VALVE PSID RELIEF VALVE OPENED PSID #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? Yes DCVA #1 CHECK VALVE CLOSED TIGHT? 1.8 PSID #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? 1.8 PSID #2 CHECK VALVE LEAKED? ❑ DCVA PASSED TEST? Yes ® No ❑ PVBA AIR INLET OPENED AT PSID AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT PSID CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ 0 No ❑ #1 CHECK VALVE CLOSED TIGHT? PSID #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? PSID #2 CHECK VALVE LEAKED? DCVA PASSED TEST? Yes ❑ No ❑ No ❑ AIR INLET OPENED AT PSID AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT PSID CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ No ❑ APPROVED ASSEMBLY? ® PROPER INSTALLATION? El REMARKS: INSPECTED BY CCS? ❑ TEST COMPANY Cosco Fire Protection TEST KIT MAKE Mid -West MODEL 845 PHONE 800-422-2031 SN 08060784 CALIBRATION DATE 3/11 1 certify that I used WAC 246 - 290 -490 approved Test Methods and Differential Pressure Test Equipment TESTER'S NAME (PRINTED) Eric Pylkki N t 4 CERTIFICATION B4578 SIGNATURE REPAIRED BY RETESTED BY CERT # DATE TESTED 6/8/11 REAPAIR DATE DATE TESTED City of Tukwila — Public Works Maintenance Department City of Tukwila — Public Works Maintenance Department 600 Minkler Blvd, Tukwila, WA 98188 Backflow Assembly Test Report Form NAME Target #0627 SERVICE ADDRESS 301 Strander Blvd CITY Tukwila ASSEMBLY LOCATION under soda machine ACCOUNT # METER# STATE Wa ZIP CODE 98188 CROSS - CONNECTION CONTROL FOR soda machine SIZE 112 MAKE Watts LINE PRESSURE AT TIME OF TEST? 55 MODEL 009QT NEW? ❑ TYPE RPBA EXISTING? SN 200870 REPLACEMTN? t INITIAL TEST RESULTS TESTS AFTER REPAIR OR CLEANING RPBA PSI DROP ACROSS #1 CHECK VALVE RELIEF VALVE OPENED 22 PSID #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? 112 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? 7_4 PSID PSI DROP ACROSS #1 CHECK VALVE RELIEF VALVE OPENED PSID PSID Yes ❑ #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? /1/ IN ❑ ❑ ❑ ❑ ❑ No ❑ /11 U 1:/ No ❑ Yes e DCVA #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? DCVA PASSED TEST? PSID ❑ #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? DCVA PASSED TEST? PSID ❑ ❑ No ❑ _ PSID Yes ❑ PSID II No • Yes 1. PVBA AIR INLET OPENED AT PSID PSID ❑ ❑ AIR INLET OPENED AT PSID PSID ❑ ❑ No ❑ AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ No • APPROVED ASSEMBLY? El REMARKS: PROPER INSTALLATION? El INSPECTED BY CCS? ❑ TEST COMPANY Cosco Fire Protection TEST KIT MAKE Mid -West MODEL 845 PHONE 800- 422 -2031 SN 08060784 CALIBRATION DATE 3/11 1 cert fy that l used WAC 246- 290 -490 approved Test Methods and Differential Pressure Test Equipment TESTER'S NAME (PRINTED) Eric PylkkI + A CERTIFICATION B4578 SIGNATURE REPAIRED BY RETESTED BY CERT # DATE TESTED DATE TESTED 6/8/11 REAPAIR DATE City of Tukwila — Public Works Maintenance Department 600 Minkler Blvd, Tukwila, WA 98188 Backflow Assembly Test Report Form NAME SERVICE ADDRESS 301 Strender Blvd CITY Tukwila ASSEMBLY LOCATION backroom of cafe Target #0627 ACCOUNT# METER # STATE Wa ZIP CODE 98188 CROSS - CONNECTION CONTROL FOR water filters SIZE 1/2 MAKE Watts MODEL 009QT NEW? n LINE PRESSURE AT TIME OF TEST? 50 TYPE RPBA SN A45919 INITIAL TEST RESULTS TESTS AFTER REPAIR OR CLEANING RPBA PSI DROP ACROSS #1 CHECK VALVE RELIEF VALVE OPENED aj PSID #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? 84 PSID PSI DROP ACROSS #1 CHECK VALVE RELIEF VALVE OPENED PSID PSID Yes ❑ #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? 112 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? 0 iii ❑ Q . ❑ ❑ 0 ❑ No ❑ Yes 0 No U DCVA 1/1 CHECK VALVE CLOSED TIGHT? 1/1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? - 1/2 CHECK VALVE LEAKED? DCVA PASSED TEST? PSID ❑ ❑ No ❑ #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? DCVA PASSED TEST? PSID ❑ ❑ No ❑ PSID PSID Yes ❑ Yes • PVBA AIR INLET OPENED AT PSID PSID AIR INLET OPENED AT PSID PSID AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT • CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ . No ❑ No ❑ APPROVED ASSEMBLY? REMARKS: PROPER INSTALLATION? INSPECTED BY CCS? ❑ TEST COMPANY Cosco Fire Protection PHONE 800- 422 -2031 TEST KIT MAKE Mid -West MODEL 845 SN 08060784 CALIBRATION DATE 3/11 1 certify that 1 used WAC 246 - 290 -490 approved Test Methods and Differential Pressure Test Equipment TESTER'S NAME (PRINTED) Eric Pylkki �1 A CERTIFICATION B4578 SIGNATURE REPAIRED BY RETESTED BY CERT # DATE TESTED 6/8/11 REAPAIR DATE DATE TESTED City of Tukwila — Public Works Maintenance Department 600 Minkler Blvd, Tukwila, WA 98188 Backflow Assembly Test Report Form NAME SERVICE ADDRESS 301 Strander Blvd CITY 'Tukwila Target #0627 ASSEMBLY LOCATION . cage for vas water ACCOUNT# METER # STATE Wa ZIP CODE 98188 CROSS-CONNECTION CONTROL FOR HVAC water SIZE 1/2 MAKE Watts LINE PRESSURE AT TIME OF TEST? 55 MODEL 009QT NEW? IZ TYPE RPBA EXISTING? l-1 SN 367721 REPLACEMTN? INITIAL TEST RESULTS TESTS AFTER REPAIR OR CLEANING RPBA PSI DROP ACROSS #1 CHECK VALVE RELIEF VALVE OPENED 3.7 PSID #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? 93 PSID PSI DROP ACROSS #1 CHECK VALVE RELIEF VALVE OPENED PSID PSID ❑ ❑ ❑ ❑ ❑ No ❑ Yes ❑ #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? / 1 ❑ CI lil /e/ No ❑ Yes :1 DCVA #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? DCVA PASSED TEST? PSID ❑ #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? in CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? DCVA PASSED TEST? PSID ❑ ❑ No ❑ _ PSID Yes ❑ PSID Yes ❑ illi No ❑ PVBA AIR INLET OPENED AT PSID PSID ❑ ❑ No ❑ AIR INLET OPENED AT PSID PSID ❑ ❑ AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ No U APPROVED ASSEMBLY? El REMARKS: PROPER INSTALLATION? El INSPECTED BY CCS? ❑ TEST COMPANY TEST KIT MAKE Mid -West Cosco Fire Protection MODEL 845 PHONE 800- 422 -2031 SN 08060784 CALIBRATION DATE 3/11 I certify that 1 used WAC 246- 290 -490 approved Test Methods and Differential Pressure Test Equipment n � TESTER'S NAME (PRINTED) E dc P r 1i 11 CERTIFICATION B4578 SIGNATURE REPAIRED BY RETESTED BY DATE TESTED 6/W11 REAPAIR DATE CERT # DATE TESTED 04 -01 -2011 • City of Tukwila 1 A- Jim Haggerton, Mayor Department of Community Development Jack Pace, Director DAVID CONTRERAS 601 SW 2 AV - SUITE 1200 PORTLAND OR 97204 RE: Permit Application No. PG10 -159 301 STRANDER BL TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 11/19/2010, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 05/18/2011. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. PG10 -159 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ?EMT F E r . '� GOPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -159 DATE: 11 -19 -10 PROJECT NAME: TARGET SITE ADDRESS: 301 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS � o0- . Building Division T-S 124 �o Pub is WorRs Fire Prevention Structural Planning Division n ❑ Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-23-10 Complete Incomplete n Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: )4- DUE DATE: 12 -21 -10 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 2 • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name SKANSKA USA BUILDING INC UBI No. 602134999 Phone 9737533500 Status Active Address 1633 Littleton Road License No. SKANSUB985RT Suite /Apt. License Type Construction Contractor City Parsippany Effective Date 12/30/2002 State NJ Expiration Date 1/12/2013 Zip 07054 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKANSCN912KQ SKANSKA CIVL NW /SKNSK BLDG JV Construction Contractor General Unused 5/18/2009 5/18/2013 Active BAUGHC0103D2 BAUGH CONSTRUCTION OREGON INC Construction Contractor General Unused 3/22/1990 9/20/2003 Archived BAUGHSI987MR BAUGH SKANSKA INC Construction Contractor General Unused 7/19/2002 7/19/2004 Re Licensed Business Owner Information Name Role Effective Date Expiration Date CORPORATION SERVICE CO Agent 12/30/2002 Amount FLEMMING, WILLIAM KEITH President 01/01/2009 GL0489601804 KENNEDY, RICHARD A Secretary 12/19/2006 HADEN, CLOVIS CLAY Secretary 01/18/2011 ZURICH AMERICAN INS CO SINICIN, LEONID Vice President 01/01/2009 KARLSTROM, JOHAN E President 12/19/2006 01/01/2009 EK, CONNY S A Vice President 12/19/2006 01/01/2009 HEALY, MICHAEL President 12/30/2002 12/19/2006 CARSON, ELIZABETH Secretary 12/30/2002 12/19/2006 PHILLIPS, BRETT Vice President 12/30/2002 12/19/2006 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS i3 SURETY CO 103904724 12/12/2002 Until Cancelled $12,000.00 12/30/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 ZURICH AMERICAN INS CO GL0489601804 08/31/2010 08/31/2011 $2,000,000.0009 /02/2010 7 ZURICH AMERICAN INS CO GL0489601804 08/31/2009 08/31/2010 $2,000,000.00 08/27/2009 https://fortress.wa.gov/lni/bbip/Print.aspx 05/06/2011 BUILDING CODE INFO SITE ZONING C -P FIRE ZONE OR DISTRICT TUKWILA FIRE DEPARTMENT SEISMIC DESIGN CATEGORY DESIGN CATEGORY "D" BUILDING OCCUPANCY CLASSIFICATION M BUILDING CONSTRUCTION TYPE 2 -N (EXISTING - UNCHANGED) BUILDING ALLOWABLE FLOOR AREA ALLOWED: UNLIMITED (FULLY SPRINKLERED) ACTUAL BUILDING AREA: 113,588 SF AFFECTED AREA OF WORK: 10,436 SF BUILDING ALLOWABLE HEIGHT '55' -0" MAX BUILDING CODE 2009 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMMENDMENTS ACCESSIBILITY CODE 2009 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMMENDMENTS 2003 ICC /ANSI A117.1 MECHANICAL CODE 2009 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMMENDMENTS PLUMBING CODE 2009 UNIFORM PLUMBING CODE W/ WASHINGTON AMMENDMENTS FIRE / LIFE SAFETY CODE 2009 INTERNATIONAL FIRE CODE W/ WASHINGTON AMMENDMENTS ELECTRICAL CODE 2008 NATIONAL ELECTRICAL CODE W/ WASHINGTON AMMENDMENTS ENERGY/ GAS 2006 WASHINGTON STATE ENERGY CODE HEALTH / FOOD SERVICE SEATTLE & KING COUNTY PUBLIC HEALTH ICC REVIEW LETTER 11.8.10 Re: T -0627 Target Store, Tukwila, To whom it may concern, 2011 MERCHANDISE REMODEL MECHANICAL SUBMITTAL I am pleased to inform you that the International Code Council has reviewed these drawings for Target Corporation and has provided appropriate notes and comments regarding code compliance, to aid in your review process_ This pre - permit application review is part of a project that provides review by ICC plans examination staff to provide valuable information to you as the local code official having jurisdiction.. We would value your input on elk program and would like to get your feedback on how your review process was affected_ Approval of the drawings and permit application, of course, rests with you, the code official as the authority having jurisdiction. Phillip Graf owski, Senior Technical Staff, (888-422-7233), has performed the plan review and would be happy to answer any questions you may have. Also as your Government Relations contact, I can be reached at 888 -422 -7233, ext. 7603, or by email at ksteti cnsont- iecsafe_org Sincerely, Kraig Stevenson International Code Council Senior Regional Manager State and Local Government Relations Washington Field Office 2122 112th Ave_, NE, Suite B -100 Bellevue, WA 98004 Toll Free - 888 -422 -7233 at 7603 REMODEL SCOPE OF WORK A. PROJECT SCOPE IS LIMITED TO THE INSTALLATION OF FREEZER AND COOLER FIXTURES ON THE EXISTING SALES FLOOR AT THE MARKET AREA AS WELL AS THE INSTALLATION OF A FREEZER /COOLER STORAGE UNIT IN THE BACK STOCKROOM. SCOPE INCLUDES THE ADDITION OF ROOFTOP CONDENSING UNITS AND ASSOCIATED PLUMBING, MECHANICAL AND ELECTRICAL WORK. B. ARCHITECTURAL WORK IS LIMITED TO MINOR DEMOLITION AND REPAIR /REPLACEMENT OF FINISHES. THE EXISTING OCCUPANCY, USE LIFE SAFETY AND EGRESS ARE NOT IMPACTED BY THE COMPLETED WORK. C. EXISTING BUILDING IS FULLY SPRINKLERED. ANY EXISTING FIRE SPRINKLERS AFFECTED BY NEW CONSTRUCTION WILL BE ADJUSTED TO MEET REQUIREMENTS. EXISTING COMPACTOR AND ASSOCIATED ITEMS TO BE REPLACED WITH NEW SELF CONTAINED COMPACTOR. THE ALARMS, ELECTRICAL, FIRE SUPPRESSION, AND MECHANICAL SYSTEMS FOR THE NEW COMPACTOR HAVE BEEN REVISED. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 O: \Remodels \0627 WA South_Center R \_ActiveCAD \062700 1 — Copy.dgn VICINITY MAP LOCATION MAP REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal d may include additional plan review fees. PROJECT TEAM ARCHITECTURAL: DAVID CONTRERAS MULVANNYG2 ARCHITECTURE 601 SW SECOND AVE SUITE 1200 PORTLAND, OR 97204 P: 971.998.1451 RICHARD PESKE, DPM TARGET CORPORATION 50 S. 10TH STREET SUITE 400, TP3 -1165 MINNEAPOLIS, MN 55403 P: 612.761.1588 F: 612.761.3322 STRUCTURAL: NIMESH PARIKH MYERS HOUGHTON & PARTNERS 4500 E. PACIFIC COAST HWY. SUITE 100 LONG BEACH, CA 90804 P: 562.985.3200 SEPARATE PERMIT REQUIRED FOR E$ RRechanit tame:war ►, Gas City of Tukwila U1LDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2010 City of la BUILDING DIVISION MECHANICAL: DOUG SCOTT HARGIS ENGINEERS, INC 600 STEWART ST. SUITE 1000 SEATTLE, WA 98101 P: 206.436.0427 REFRIGERATION: TONY YTUARTE CTA ARCHITECTS ENGINEERS 1185 GROVE ST. BOISE, ID 83702 P: 208.343.3531 ELECTRICAL: CHARLIE MUSSER HARGIS ENGINEERS, INC 600 STEWART ST. SUITE 1000 SEATTLE, WA 98101 P: 206.859.5382 DATE ISSUED ISSUES AND REVISIONS DRAWN BY CHECKED BY ARCHITECTS PROJECT NO. RobH 11 —NOV -2010 07:12 TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE VERSION T062 7 R2010_08 08-06-10 PROJECT CODE 270627 CONFIGURATION LL TITLE SHEET INDEX GENERAL G001 PROJECT INFORMATION PLUMBING, HVAC, FIRE PROTECTION AND REFRIGERATION PM01 MECHANICAL INDEX AND DETAILS PM02 PLUMBING & MECHANICAL SCHEDULES AND RISER DIAGRAMS PD01 PLUMBING DEMOLITION PLANS P351 STOCK ROOM PLUMBING PLANS P411 CONDENSATE VACUUM PLANS P421 CONDENSATE VACUUM DETAILS P431 CONDENSATE VACUUM DETAILS M111 MARKET AREA HVAC DEMO AND NEW WORK PLANS M331 OFFICE AREA HVAC DEMO AND NEW WORK PLANS F111 FIRE PROTECTION PLAN RD01 REFRIGERATION DEMOLITION PLAN R111 REFRIGERATION SYSTEM PLAN R141 REFRIGERATION ROOF PLAN R401 MARKET CASES SETTING PLAN R411 MARKET & PARTIAL ROOF PIPING PLANS R421 WALK -IN COOLER & FREEZER PIPING PLAN R501 REFRIGERATION DETAILS R511 REFRIGERATION DETAILS R521 REFRIGERATION DETAILS R601 REFRIGERATION SCHEDULES R611 REMS CONTROL WIRING PLAN & SCHEDULES R621 MARKET & WALK -IN CONTROL WIRING PLANS FELE COPY Permit No., p c-, 1 0 ` Flan review approval is subject to errors and omissions. Approval of construction documents does not authorize tic violation of any adopted code or ordinance. Receipt of approved Field Copy and , t s is acknowledged: Date: A? /1 I City OflUkwila BUILDING DIVISION NOV 19 2010 PERMIT CENTER ?Wb5e PROJECT INFORMATION SHEET G001 T -0627 SOUTH CENTER, WA • PIPE HANGER SCHEDULE WATER, WASTE, GAS, RWC, AND FIRE PROTECTION PIPING PIPE SIZE HANGER SPACING Sch 40 Sch 10 THREADED LIGHT WALL GROOVED LIGHT WALL TYPE L COPPER PVC/ ABS 1' 8' -0' OR LESS' H -1 H -1 H -1 H -1 H -1 H -1 D. SCOTT 12' -0' H -1 H -1 H -1 H -1 N/A N/A 11/2' 10' -0' OR LESS( H -1 H -1 H -1 H -1 H -1 H -1 TURNING DOWN 12' -0' H -1 H -1 H -1 H -1 N/A N/A R 15' -0' H -1 H -1 N/A H -1 N/A N/A 2' 10' -0' OR LESS' H -1 H -1 • H -1 H -1 H -1 H -1 12' -0' H -1 H -1 H -1 H -1 N/A N/A 15' -0' H -1 H -1 N/A H -1 N/A N/A 21/2' 9' -0' OR LESS' H -1 H -1 H -1 H -1 H -1 H -1 12' -0' H -2 H -1 H -1 H -1 N/A N/A 15' -0' H -2 H -1 N/A H -1 N/A N/A 3' 10' -0' OR LESS' N/A H -1 H -1 H -1 H -1 H -1 12' -0' N/A H -1 H -2 H -1 N/A N/A 15, -0' N/A H -2 N/A H -2 N/A N/A 4' 4' -0' N/A H -1 N/A H -1 H -1 H -1 i/� 1 8' -0' N/A H -1 N/A H -1 H -1 N/A 10' -0' N/A H -2 N/A H -2 H -2 N/A 12' -0' N/A H -2 N/A H -2 N/A N/A 15' -0' N/A H -2 N/A H -2 N/A N/A 6' 4' -0' N/A H -1 N/A H -1 N/A H -1 8' -0' N/A H -2 N/A H -2 N/A N/A 10' -0' N/A H -3 N/A H -3 N/A N/A 12' -0' N/A H -3 N/A H -3 N/A N/A 15' -0' N/A H -3 N/A H -3 N/A N/A 8' 4' -O' N/A H -2 N/A N/A N/A H -2 8' -0' N/A H -3 N/A N/A N/A N/A 10' -0' N/A H -3 N/A N/A N/A N/A 12' -0' N/A H -3 N/A N/A N/A N/A 15' -0' N/A H -3 N/A N/A N/A N/A 10' 4' -0' N/A H -3 N/A N/A N/A H -2 12'+ 4' -0' N/A H -3 N/A N/A N/A H -3 • REFER TO SPECIFICATION SECTION 20 0050 FOR MAXIMUM ALLOWABLE HANGER SPACING FOR TYPE L COPPER AND PVC /ABS PIPING. N/A = NOT ALLOWED OR NOT APPLICABLE GENERAL NOTES: A. THIS PIPE HANGER SCHEDULE SHOWS MAXIMUM ALLOWABLE HANGER SPACING BASED ON PIPE WEIGHT AND STRUCTURAL CONSTRAINTS. REFER TO SPECIFICATION SECTION 20 0050 FOR ADDITIONAL PIPE HANGER REQUIREMENTS INCLUDING REQUIRED HANGER ROD DIAMETER AND MAXIMUM HANGER SPACING BASED ON PIPE MATERIAL AND PIPE DIAMETER. B. SUPPORT PIPING WITHIN 6' OF JOIST TOP AND BOTTOM CHORD PANEL POINT, C. MAXIMUM LOAD ON ANY PANEL POINT IS 100 LBS UNLESS APPROVED BY STRUCTURAL ENGINEER. D. LOCATE POINT LOADS A MINIMUM OF 6' -0' FROM ANY OTHER POINT LOAD ON THE SAME JOIST. E. FIRE PROTECTION SPRINKLER PIPING SUPPORT SHALL COMPLY WITH REQUIREMENTS OF NFPA AND LOCAL CODE AUTHORITIES. F. DO NOT DEVIATE FROM PIPE HANGER DETAILS AS SHOWN. DEVIATION FROM HANGER DETAILS MAY VOID JOIST MANUFACTURER'S WARRANTY. G. LOCATE TOP OF PIPE AT 6' MINIMUM BELOW ROOF DECK. TYPE "H -1" HANGERS BEAM CLAMP TOP CHORD BEAM CLAMP TO TOP CHORD OF JOIST WITHIN 6' OF PANEL POINT THREADED ROD SWIVEL RING BEAM CLAMP BOTTOM CHORD ROOF DECK JOIST /BEAM BEAM CLAMP TO BOTTOM CHORD OF JOIST WITHIN 6' OF PANEL POINT THREADED ROD SWIVEL RING TYPE "H -2" HANGERS BEAM CLAMP TOP CHORD THREADED ROD TOP CHORD ROOF DECK BEAM CLAMP TO TOP CHORD OF JOIST WITHIN 6' OF PANEL POINT THREADED ROD SWIVEL RING JOIST ROOF DECK THREADED ROD TO TOP CHORD OF JOIST WITHIN 6' OF PANEL POINT SWIVEL RING JOIST BEAM CLAMP BOTTOM CHORD ROOF DECK JOIST BEAM CLAMP TO BOTTOM CHORD OF JOIST WITHIN 6' OF PANEL POINT THREADED ROD SWIVEL RING THREADED ROD BOTTOM CHORD THREADED ROD TO BOTTOM CHORD OF JOIST WITHIN 6' OF PANEL POINT SWIVEL RING TYPE "H -3" HANGERS 3/8' HEX NUT WITH JUMBO WASHER TOP CHORD (TYP) -ROOF DECK - ROOF DECK JOIST L THREADED ROD TOP CHORD TRAPEZE 6 � 9 THREADED ROD TOP CHORD TRAPEZE 3 ' STRUT NUT WITH - �- /8 HEX NUT AND JUMBO WASHER BEAM i (EACH SIDE) SINGLE STRUT CHANNEL OR PIPE (SIZE IN ACCORD WITH NFPA) THREADED ROD HANGER WITH SWIVEL RING JOIST BEAM SINGLE STRUT CHANNEL OR PIPE (SIZE IN ACCORD WITH NFPA FOR FIRE PROT, SIZE FOR PIPE LOAD FOR RWC) 6 BEAM CLAMP TRAPEZE STRUT CHANNEL BEAM CLAMP (TYP) TYPICAL JOIST HANGER LAYOUT 'X' BOTTOM CHORD PANEL POINT BOTTOM CHORD ADD ADDITIONAL WEB MEMBER IF 'X' DIM IS GREATER THAT 6' FROM PANEL POINT LOCATIONS TO PIPE /DUCT SUPPORT, SEE STRUCTURAL PIPE HANGER DETAILS NOT TO SCALE 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T.\ D_...,..,J_I_\ nLr)7 \A /A C_..iL_ r^__i__ In n_i :.,_/"nrM\ nL77,......M �... HVAC SYMBOLS ~. PANELPOIIVT TOP CHORD t- 7 DUCT (1st FIGURE -SIDE SHOWN 2nd FIGURE -SIDE NOT SHOWN) 11.8.10 24x20 + + 7 DUCT SECTION PIPE /DUCT HANGER L i DUCT SECTION (EXHAUST OR RETURN) D. SCOTT BOTTOM CHORD PANEL POINT BOTTOM CHORD ADD ADDITIONAL WEB MEMBER IF 'X' DIM IS GREATER THAT 6' FROM PANEL POINT LOCATIONS TO PIPE /DUCT SUPPORT, SEE STRUCTURAL PIPE HANGER DETAILS NOT TO SCALE 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T.\ D_...,..,J_I_\ nLr)7 \A /A C_..iL_ r^__i__ In n_i :.,_/"nrM\ nL77,......M �... HVAC SYMBOLS ITEM INDICATED DOUBLE LINE DRAWING REPRESENTATION DUCT (1st FIGURE -SIDE SHOWN 2nd FIGURE -SIDE NOT SHOWN) 11.8.10 24x20 + + PERMIT SET DUCT SECTION DRAWN BY DUCT SECTION (EXHAUST OR RETURN) D. SCOTT 24x12 SUPPLY DUCT UP OR DOWN TURNINGS UP 24x12 I n V \ DOWN RETURN OR EXHAUST DUCT TURNING UP OR DOWN D. BENNETT TURNING---1 I UP 24x12 �� TURNING DOWN INCLINED RISE (R) OR DROP (D) (ARROW IN DIRECTION OF AIR FLOW) ARCHITECTS PROJECT NO. 24x20 R ECCENTRIC DUCT FITTING `20x12 24x12 CONCENTRIC DUCT FITTING 24x12 20x12 BRANCH DUCT TAKE- OFF USING RECTANGULAR DUCTWORK MAIN 12x11 24x12 a DAMPER 8•ir DAMPER IN HORIZONTAL OR VERTICAL DUCT (REFER TO MECHANICAL SYMBOLS FOR DAMPER TYPES) 1 I 24x12 DIFFUSER DESCRIPTION C: REFERS TO TYPE 12: NECK SIZE (SQ OR RD) 500: CFM (REFER TO PM02 FOR DIFFUSER TYPE) 0500 - 4111111111111111 � SUPPLY REG STER RETURN OR EXHAUST DESCRIPTION H: REFERS. TO TYPE 12x8: REGISTER SIZE 200: CFM (REFER TO PM02 FOR REGISTER TYPE) ©200 CEILING RETURN GRILLE DESCRIPTION F: REFERS TO TYPE 24x12: GRILLE SIZE (REFER TO PM02 FOR GRILLE TYPE) 24x12® TRANSFER GRILLE & DUCTWORK DESCRIPTION F: REFERS TO TYPE 24x6: GRILLE SIZE (REFER TO PM02 FOR GRILLE TYPE) 10' 24x6 24x6 42 i/� 1 TRANSFER GRILLE & DUCTWORK DESCRIPTION F: REFERS TO TYPE 24x6: GRILLE SIZE (REFER TO PM02 FOR GRILLE TYPE) _ .24x6 .24x6 LINEAR SLOT DIFFUSER WITH BOOT DESCRIPTION K: DIFFUSER TYPE 8'A: BOOT NECK SIZE 1.0': SLOT WIDTH 330: CFM (REFER TO PM02 FOR DIFFUSER TYPE) 8'� -1,0' 330 ROD HANGER JOIST OR BEAM TYPICAL STEEL ANGLE --y ROOF DECK TYPICAL DUCT WIDTHS 36' OR GREATER DUCT WIDTHS LESS THAN 36' PRE - PUNCHED CHANNEL SUPPORT FASTENED TO TOP OR BOTTOM CHORD OF JOIST, TYPICAL. STRAP HANGER BAND SAME AS STRAP HANGER 36' MAXIMUM DUCT DIAMETER GREATER THAN 36' DUCT DIAMETER STRAP HANGER SCREW STRAP TO DUCT. MINIMUM 1' STRAP LENGTH ON UNDERSIDE OF DUCT. ROD HANGER OR STRAP HANGER GENERAL NOTES: A. REFER TO 'SMACNA HVAC DUCT CONSTRUCTION STANDARDS' FOR HANGER REQUIREMENTS. INCLUDING SIZES OF STRAP HANGERS, ROD HANGERS, STEEL ANGLES, AND FASTENERS. B. SUPPORT FROM JOIST TOP OR BOTTOM CHORD WITHIN 6' OF PANEL POINT. C. MAXIMUM LOAD ON ANY PANEL IS 100 LBS, UNLESS APPROVED BY STRUCTURAL ENGINEER. D. LOCATE POINT LOADS A MINIMUM OF 6' -0' FROM ANY OTHER POINT LOAD ON THE SAME JOIST. DUCT HANGER DETAILS NOT TO SCALE MECHANICAL SYMBOLS SYMBOL DESCRIPTION v. 0 000u aatujaaaamo 0 (o) K51 XX' -X' t REF v SD RWC b RWC CD VAC G • GIN - CWV SW SW • MN= NNE (E) (N) c LAVATORY (MULTI - STATION NOT SHOWN) WATER CLOSET URINAL SINK JANITORS SINK ELECTRIC WATER COOLER HUB DRAIN FLOOR DRAIN FLOOR SINK ROOF DRAIN CLEAN OUT TRENCH DRAIN VENT THROUGH ROOF WALL HYDRANT /INSIDE HOSE BIBB GAS SHUTOFF VALVE PRESSURE REGULATOR INVERT ELEVATION TAG TOP CONNECTION BOTTOM CONNECTION DROP IN DIRECTION OF FLOW RISE IN DIRECTION OF FLOW SHUTOFF VALVE WAFER CHECK VALVE STRAINER STRAINER WITH BLOW DOWN VALVE UNION SWING CHECK VALVE COLD WATER HOT WATER RECIRCULATING HOT WATER REFRIGERANT PIPING VENT STORM DRAIN (BELOW GRADE) RAINWATER CONDUCTOR (ABOVE GRADE) RAINWATER CONDUCTOR (ABOVE GRADE) CONDENSATE DRAIN CONDENSATE VACUUM PIPING NATURAL GAS GREASE WASTE COMBINATION WASTE & VENT SANITARY WASTE ABOVE FLOOR SANITARY WASTE BELOW FLOOR PIPE BREAK CONNECT TO EXISTING OR SYSTEMS PROVIDED NIC OWNER FURNISHED MECHANICAL EQUIPMENT SYMBOL MECHANICAL EQUIPMENT TAG BALANCING DAMPER THERMOSTAT /TEMPERATURE SENSOR TEMPERATURE & HUMIDITY SENSOR EXISTING EQUIPMENT NEW EQUIPMENT PIPE RING HANGER PIPE GALVANIZED STEEL SHIELD HIGH DENSITY INSULATION INSERT OR WOOD BLOCK SEE SPECIFICATIONS CLEVIS HANGER INSULATED PIPE AT HANGER DETAIL PLUMBING, HVAC AND FIRE PROTECTION PM01 PM02 PD01 P351 P411 P421 P431 M111 M331 F111 MECHANICAL INDEX AND DETAILS PLUMBING & MECHANICAL SCHEDULES AND RISER DIAGRAMS PLUMBING DEMOLITION PLANS STOCK ROOM PLUMBING PLANS CONDENSATE VACUUM PLANS CONDENSATE VACUUM DETAILS CONDENSATE VACUUM DETAILS MARKET AREA HVAC DEMO AND NEW WORK PLANS OFFICE AREA HVAC DEMO AND NEW WORK PLANS FIRE PROTECTION PLAN REVIEWED FOR CODE COMPLIANCE A PPPMED DEC 10 2010 City of Tukwila BUILDING DIVISION DATE ISSUED ISSUES AND REVISIONS VERSION MR201008 0$ -06 -10 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY D. SCOTT CHECKED BY D. BENNETT ARCHITECTS PROJECT NO. ns_Nnv_')n1n 1g•g7 NOT TO SCALE EXISTING PIPING SYMBOLS DESCRIPTION SYMBOL - - -v— cc c Sir EXISTING COLD WATER EXISTING HOT WATER EXISTING VENT EXISTING CONDENSATE PIPING EXISTING NATURAL GAS EXISTING SANITARY WASTE EXISTING CONDITION SYMBOLS (DEMO DRAWINGS) SYMBOL DESCRIPTION EX EXISTING SYMBOL EX EXISTING PIPE LINETYPE DENOTES EXISTING EQUIPMENT /DUCT HATCHING DENOTES PIPING OR EQUIPMENT TO BE REMOVED CONDITION SYMBOLS (NEW DRAWINGS) DESCRIPTION EXISTING PIPE TO REMAIN LINETYPE DENOTES EXISTING EQUIPMENT /DUCT TO REMAIN QUALITY ASSURANCE REVIEW REVIEWED BY: DUANE BENNETT REVIEWERS PHONE: 206- 448 -3376 DATE: 1V3/10 GENERAL NOTES: A. EXISTING DUCTWORK AND PIPING INDICATED ON PLAN WAS TAKEN FROM EXISTING MECHANICAL PLANS AND FIELD OBSERVATION AND SHALL NOT BE CONSIDERED 100 PERCENT ACCURATE. CONTRACTOR SHALL VERIFY LOCATION OF EXISTING SYSTEMS PRIOR TO CONSTRUCTION AND SHALL NOTIFY OSR OF POTENTIAL CONFLICTS. B. CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF DRAWINGS AND SPECIFICATIONS FOR BIDDING PURPOSES. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF .CONDITIONS THAT OCCUR DUE TO NOT BEING FAMILIAR WITH CONTRACT DOCUMENTS. C. PIPING ABANDONED IN PLACE SHALL BE CAPPED, PLUGGED AND CONCEALED. PLUGGING AND CAPPING SHALL BE DONE IN A MANNER AS TO ALLOW REOPENING AND REUSE LATER. D. PATCHING OF PENETRATIONS WHERE PIPING OR DUCTWORK IS REMOVED SHALL BE BY GENERAL CONTRACTOR. E. CONCRETE CUTS (BY GENERAL CONTRACTOR) SHALL BE STRAIGHT AND CLEAN, REPLACE SLAB WITH CONCRETE FLUSH AND SMOOTH WITH ADJACENT SURFACE. F. FIELD VERIFY LOCATIONS AND QUANTITY OF EXISTING EQUIPMENT, FIXTURES, DUCTWORK, AND PIPING NECESSARY TO COMPLETE SCOPE OF WORK. G. ARRANGE REQUIRED WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE DISRUPTIONS WITH TARGET OSR AND STORE MANAGER. H. SUBMIT (2) COPIES OF REDLINED AS -BUILT UPDATES. ONE COPY TO BE RETAINED AT STORE. RETURN SECOND COPY TO OSR TO BE FORWARDED TO MECHANICAL ENGINEER. I. COORDINATE PHASES OF DEMOLITION WITH ARCHITECTURAL DEMOLITION PLANS. J. PROVIDE OSR AND TARGET FACILITIES MANAGEMENT FIRST RIGHT OF REFUSAL ON EQUIPMENT TO BE REMOVED. l'6104 is RECEIVED NOV 19 2010 PERMIT CENTER TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR201008 0$ -06 -10 TITLE MECHANICAL INDEX & PROJECT CODE 270627 CONFIGURATION LL DETAILS SHEET PMO1 NOT USED STOCKROOM WATER RISER REF: 2/P351 ROOF DECK (2) -1/ 'Jdx2' LAG SCREWS TO SWG- 2V -0380 ITW IDEWINDER SAMMYS FOR WOOD, TYP. (E) PURLIN DIAGONAL BRACE SEE SCHEDULE COPE LEG OF ANGLE HANGER ROD CLIP NOT TO SCALE P134 UNISTRUT ANGLE W/ (2) -1 'Jdx2' LAG SCREWS TO PUR IN OR ITW BUILDEX SAMMYS SWG -2 -380 'SIDEWINDERS' FOR WOOD, TYP. (E) SUB PURLI ' ADD VERTICAL ANGLE FROM SCHEDULE WHEN ROD GREATER ' THAN MAxIMuM ALLO*ED HANGER ROD AND ANGLE SEE SCHEDULE /40 NOTE: INSTALL TRANSVERSE PIPE BRACING ON ALL INTERIOR PIPING EXCEEDING 30 FEET IN LENGTH. MAX SPACING IS 40 FEET OC. TRANSVERSE PIPE BRACING '' /8' GROOVE WELD - 1' LONG /24' OC PIPE SIZE - SEE SCHEDULE PIPE BRACING SCHEDULE PACKAGED ROOFTOP UNIT SCHEDULE T -0627 - Target South Center, WA DIAGONAL BRACE & /OR VERTICAL ANGLE LONGITUDINAL BRACE 11/5/20108:25 ROD SIZE Nominal Cooling Cap. (Tons) Tons Model Refrig Type Supply Outdoor Cooling Design Conditions Cooling Performance Heating Design Heating Performance CLEVIS Electrical Data Y4' MACH BOLT Net Installed Wt. (Ibs) Options Unit No. Blower Type Air Flow (CFM) ESP (in. WC) Fan Motor Nominal (hp) BHP Fan RPM Air Flow (CFM) Outdoor Air D.B. (°F) Outdoor Air W.B. (F) Mixed Air D.B. ( °� Mixed Air W.B. ( °� Gross Total (BTUH) Net Total BTUH (BTUH) ) Gross Sensible (BTUH) Net Sensible (BTUH) System Moist Rem (lb/hr) Coil LAT D.B. ( °F) Coil LAT W.B. ( °F) Unit LAT D.B. ( °F) _ Unit LAT W.B. ( °F) DX Cooling Outdoor D.B. (°F) Mixed D.B. ° (°F) Fuel Type System Input (BTUH) System Output (BTUH) LAT D.B. ( °� _ Mech Voltage MCA Max Fuse FLA EER IPLV Thermal Eff CLEVIS 10.0 LGH120H4B R -410A Constant 4,700 0.8 5.0 3.59 1,119 1,010 82.1 65.0 79.4 63.1 46,087 43,690 39,930 37,533 5.8 52.9 52.1 56.6 54.2 12.5 23.0 72.7 NG 130,000 104,000 93.2 80% 460V3Ph 30.0 35.0 27.1 1,344 1,2,4,6,8,9,11,12,14,15 RTU -17 OFFICES (VAV) FAC, 3) MOTORIZED OADAMPERS FAC, 4) POWER EXHAUST - FAC, 5) BAROMETRIC RELIEF FAC, 6) CIRCUIT BREAKER - FAC, 7) SASMOKE DET SINGLE PNT - FAC, 8) SASMOKE DETECTOR - FAC, 9) CORROSION PROTECTION - FAC, 10) LOW NOX FAC, 11) PVC DRAIN TRAP - FAC, 12) STANDARD CAP - FAC, 13) TARGET BACNET MODULE - FAC14) TARGET IMC BACNET MODULE - FAC15) GFCI - FLD 1) 2 IN MERV8 FILTER - FAC, 2) ECONOMIZER WIRED /FAC NOT USED STOCKROOM WATER RISER REF: 2/P351 ROOF DECK (2) -1/ 'Jdx2' LAG SCREWS TO SWG- 2V -0380 ITW IDEWINDER SAMMYS FOR WOOD, TYP. (E) PURLIN DIAGONAL BRACE SEE SCHEDULE COPE LEG OF ANGLE HANGER ROD CLIP NOT TO SCALE P134 UNISTRUT ANGLE W/ (2) -1 'Jdx2' LAG SCREWS TO PUR IN OR ITW BUILDEX SAMMYS SWG -2 -380 'SIDEWINDERS' FOR WOOD, TYP. (E) SUB PURLI ' ADD VERTICAL ANGLE FROM SCHEDULE WHEN ROD GREATER ' THAN MAxIMuM ALLO*ED HANGER ROD AND ANGLE SEE SCHEDULE /40 NOTE: INSTALL TRANSVERSE PIPE BRACING ON ALL INTERIOR PIPING EXCEEDING 30 FEET IN LENGTH. MAX SPACING IS 40 FEET OC. TRANSVERSE PIPE BRACING '' /8' GROOVE WELD - 1' LONG /24' OC PIPE SIZE - SEE SCHEDULE PIPE BRACING SCHEDULE PIPE SIZE HANGER TYPE DIAGONAL BRACE & /OR VERTICAL ANGLE LONGITUDINAL BRACE TOP CONN OF DIAG & LONG ANGLES ROD SIZE MAXIMUM LENGTH FOR RODS UP TO 2' CLEVIS 2•X2'X16 GA 2'/2'X2%2'X16 GA 1/2' LAG BOLT 11 /2'Jd 25' 21/2' CLEVIS 2'X2'X16 GA 21/2'X21/2•X16 GA Y4' MACH BOLT I /2'A 25' 3' CLEVIS 2'X2'X16 GA 21/2'X21/2•X16 GA Y4' MACH BOLT 1/2'ft 25' 31/2' CLEVIS 2'X2'X16 GA 21/2'X21/2'X16 GA Y4' MACH BOLT I /2'A 25' 4' CLEVIS 2'X2'X16 GA 21/2'X21/2'X16 GA Y4' MACH BOLT WA 31' 5' CLEVIS 2•X2'X16 GA 21/2'X21/2'X16 GA Y4' MACH BOLT 5/8'fili 31' 6' CLEVIS 21/2'X21/2'X16 GA 21/2'X21/2'X16 GA Y4' MACH BOLT Y4'l 37' 8' CLEVIS 2'/2'X2'/2'X12 GA 21/2•X21/2'X12 GA Y4' MACH BOLT /8'A 43' NOTES: 1. SCHEDULE APPLIES TO WATER (& SPRINKLER) PIPES 2' AND LARGER 2. SCHEDULE APPLIES TO FUEL (GAS) PIPES 1' AND LARGER PIPE BRACING SCHEDULE 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 NOT TO SCALE i HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.harg1s.biz i NOT TO SCALE 3' 2' • . 4' VTR ROOF S`' co c(e i�,. v .' 2. 4'�4s( CO/Cr 4' ss 2'- ' I 1. - 1 2 . ."1 , ,.- - ' -I- -2' STANDP /PE 4 1%7"; I . 4• -' - 2' - .C.1 3„ 4'VTR ,PROOF 1 � r �� 4'FD -1`•� 2' C09♦ KO4 ■ ' ♦ 2' �� ♦` i' ' CO r i 1 STOCKROOM WASTE & VENT RISER REF: 1 /P351, 2/P351 ROOF DECK NOT TO SCALE P134 UNISTRUT ANGLE W/ (2) -I 'Jdx2' LAG SCREWS TO SWG- 2V -0380T SIDEWINDERS SAMMYS WOOD, TYP. (2)-1/2.'0)(2' LAG SCREWS TO PUR IIV, OR ITW BUILDEX SAMMYS SWG -25 -380 'SIDEWINDERS' FOR WOOD, TYP. LONGITUDINAL BRACE SEE SCHEDULE ROD HANGER & VERTICAL ANGLE BEAM ATTACHMENT 1/8' FILLET WELD FOR PIPE SIZE SEE SCHEDULE PIPE CLAMP a 2 a 2 LONGITUDINAL BRACING AT 80' -0' OC MAX., UNLESS OTHERWISE NOTED. THIS BRACING DETAIL APPLIES ONLY FOR COLD WATER PIPE & GAS PIPE WHERE MOVEMENT OF THE PIPE DUE TO TEMPERATURE DIFFERENTIAL IS NEGLIGIBLE. WHEN THERMAL EXPANSION OR CONTRACTION IS INVOLVED, PROVIDE LONGITUDINAL BRACES AT ANCHOR POINTS. THE LONGITUDINAL BRACES AND THE CONNECTIONS MUST BE CAPABLE OF RESISTING THE FORCE INDUCED BY EXPANSION AND CONTRACTION. FOUR -WAY BRACE ELEVATION LONGITUDINAL PIPE BRACING ROOF FOUR -WAY BRACE - SEE (PIPE MUST ROTATE WITHIN BRACE) FLEXIBLE COUPLING OR 'VICTAULIC' TYPE COUPLING RISER(S) SLEEVE FLOOR NOT TO SCALE NOT TO SCALE EQUIPMENT RESPONSIBILITY MATRIX PACKAGED ROOFTOP AIR CONDITIONING EQUIPMENT SCHEDULE 23 OWNER FURNISHED RTU FURNISH BY SYSTEM FAN DATA GAS HEATING DATA COOLING DATA ALTITUDE: 449 FT GAS HEATING CONTENT: 1000 BTU /CF COILS SIZED FOR 91° AMBIENT ROOF TEMPERATURE. UNIT NO AREA SERVED AAON MODEL NO CFM MIN OA (CFM) EXTERNAL SP ('WG) TOTAL SP ('W6) RPM ELEC MOTOR TOR (MBH)NPUT GAS UNIT DISCHARGE (° ) STAGES ENT AIR TEMP (DEG F) COIL DISCHARGE T (°° ) COIL CAPACITY MIN SEER REMARKS DB WB TOTAL (MBH) SENS (MBH) STAGES -6 SALES CARR /ER 4RTU 8DPEO14 3845 510D ARCHITECTS PROJECT NO. PRE - SLOPED POLYMER CONCRETE CHANNEL UNITS WITH OVERLAY EDGE PROTECTION RAIL OF DUCTILE IRON AND A C250 SLOTTED DUCTILE IRON GRATE WITH LOCKING MECHANISM. LENGTH OF TRENCH DRAIN SHOWN ON PLANS IS BASED ON USING JOSAM MEADRAIN STANDARD SECTION LENGTH OF 39.4 INCHES. TOP OF GRATE SHALL BE FLUSH WITH FINISHED FLOOR. 46O/3f WHITE ENAMEL STEEL 24'x6' FACE; Y4' BLADE SPACING, SINGLE DEFLECTION, WITH LDE ANGLE PARALLEL RFIXEDL AT 22 5 DEG. SHORT DIMENSION. 1 VACUUM PUMP CV -1 ACORN VACUUM, INC. M1 OWNER PLBG CONTR ELEC EXISTING TO REMAIN - REBALANCE TO CFM SHOWN RTU -10 SALES CARR /ER SODPEO/4 3845 NOT REQUIRED NOT REQUIRED NOT REQUIRED PLBG CONTR 460/3f PLBG CONTR EXISTING TO REMAIN - REBALANCE TO CFM SHOWN 1. TARGET OWNERS SITE REPRESENTATIVE TO CONTACT TEST AND BALANCE CONTRACTOR ASSIGNED TO STORE TO SCHEDULE BALANCING OF MECHANICAL SYSTEMS A MINIMUM TWO WEEKS PRIOR TO BALANCING. 2. TARGET OWNERS SITE REPRESENTATIVE TO CONTACT OWNERS ENERGY MANAGEMENT SYSTEM (EMS) CONTRACTOR TO VERIFY LENGTHS OF EMS CABLE REQUIRED. REMODEL PROJECTS WITH LIMITED SCOPE OF WORK WILL NOT HAVE EMS TECHNICIAN ON -SITE, EMS VENDOR PROVIDES SHOP DRAWINGS AND TELEPHONE SUPPORT FOR ELECTRICAL CONTRACTOR WHO PULLS AND TERMINATES EMS CABLE, MOUNTS EMS SENSORS, AND CONTACTS EMS VENDOR TO VERIFY NEW EQUIPMENT OPERATION. REF: 1 /P351, 2/P351 ROOF DECK NOT TO SCALE P134 UNISTRUT ANGLE W/ (2) -I 'Jdx2' LAG SCREWS TO SWG- 2V -0380T SIDEWINDERS SAMMYS WOOD, TYP. (2)-1/2.'0)(2' LAG SCREWS TO PUR IIV, OR ITW BUILDEX SAMMYS SWG -25 -380 'SIDEWINDERS' FOR WOOD, TYP. LONGITUDINAL BRACE SEE SCHEDULE ROD HANGER & VERTICAL ANGLE BEAM ATTACHMENT 1/8' FILLET WELD FOR PIPE SIZE SEE SCHEDULE PIPE CLAMP a 2 a 2 LONGITUDINAL BRACING AT 80' -0' OC MAX., UNLESS OTHERWISE NOTED. THIS BRACING DETAIL APPLIES ONLY FOR COLD WATER PIPE & GAS PIPE WHERE MOVEMENT OF THE PIPE DUE TO TEMPERATURE DIFFERENTIAL IS NEGLIGIBLE. WHEN THERMAL EXPANSION OR CONTRACTION IS INVOLVED, PROVIDE LONGITUDINAL BRACES AT ANCHOR POINTS. THE LONGITUDINAL BRACES AND THE CONNECTIONS MUST BE CAPABLE OF RESISTING THE FORCE INDUCED BY EXPANSION AND CONTRACTION. FOUR -WAY BRACE ELEVATION LONGITUDINAL PIPE BRACING ROOF FOUR -WAY BRACE - SEE (PIPE MUST ROTATE WITHIN BRACE) FLEXIBLE COUPLING OR 'VICTAULIC' TYPE COUPLING RISER(S) SLEEVE FLOOR NOT TO SCALE NOT TO SCALE EQUIPMENT RESPONSIBILITY MATRIX EQUIPMENT: SPECIFIED MFR.: FURNISH BY INSTALL BY: ELECTRICAL CONNECTION: EQUIPMENT START UP: FURNISH EMS CABLE: INSTALL EMS CABLE: EMS CABLE TERMINATION: FURNISH CONTROL CONTACTOR: WIRE DEVICE TO CONTROL CONTACTOR: SMOKE DETECTOR: FURNISH & INSTALL SPACE SENSOR: DELIVERY SCHEDULE COORDINATION: EMS CONTROL HARDWARE: TESTING & BALANCING OF EQUIPMENT: ROOFTOP UNITS RTU -17 LENNOX OWNER MECH ELEC MECH SEE NOTE 1 OWNER'S EMS CONTRACTOR ELEC OWNER'S EMS CONTRACTOR NOT REQUIRED NOT REQUIRED EQUIPMENT MANUFACTURER OWNER'S EMS CONTRACTOR OWNER'S SITE REPRESENTATIVE NOT REQUIRED OWNER'S BALANCING CONTRACTOR 1 N SUPPLY REGISTER 510D ARCHITECTS PROJECT NO. PRE - SLOPED POLYMER CONCRETE CHANNEL UNITS WITH OVERLAY EDGE PROTECTION RAIL OF DUCTILE IRON AND A C250 SLOTTED DUCTILE IRON GRATE WITH LOCKING MECHANISM. LENGTH OF TRENCH DRAIN SHOWN ON PLANS IS BASED ON USING JOSAM MEADRAIN STANDARD SECTION LENGTH OF 39.4 INCHES. TOP OF GRATE SHALL BE FLUSH WITH FINISHED FLOOR. WHITE ENAMEL STEEL 24'x6' FACE; Y4' BLADE SPACING, SINGLE DEFLECTION, WITH LDE ANGLE PARALLEL RFIXEDL AT 22 5 DEG. SHORT DIMENSION. 1 VACUUM PUMP CV -1 ACORN VACUUM, INC. M1 OWNER PLBG CONTR ELEC PLBG CONTR REFR TO REFRIG DWGS REFR TO REFRIG DWGS REFR TO REFRIG DWGS NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED PLBG CONTR NOT REQUIRED PLBG CONTR 1. TARGET OWNERS SITE REPRESENTATIVE TO CONTACT TEST AND BALANCE CONTRACTOR ASSIGNED TO STORE TO SCHEDULE BALANCING OF MECHANICAL SYSTEMS A MINIMUM TWO WEEKS PRIOR TO BALANCING. 2. TARGET OWNERS SITE REPRESENTATIVE TO CONTACT OWNERS ENERGY MANAGEMENT SYSTEM (EMS) CONTRACTOR TO VERIFY LENGTHS OF EMS CABLE REQUIRED. REMODEL PROJECTS WITH LIMITED SCOPE OF WORK WILL NOT HAVE EMS TECHNICIAN ON -SITE, EMS VENDOR PROVIDES SHOP DRAWINGS AND TELEPHONE SUPPORT FOR ELECTRICAL CONTRACTOR WHO PULLS AND TERMINATES EMS CABLE, MOUNTS EMS SENSORS, AND CONTACTS EMS VENDOR TO VERIFY NEW EQUIPMENT OPERATION. 45° �� ti 4 _ I .� 4 D� 1� ✓' WALL r ``i ' 'r�' `'� -., ,\ D -A Y 4 D 4 �'� D 4 D N �'� D 4 Dr,- �, J .� 4 r, r ti� h D n �`R 4 r, ` �` NOTE: PROVIDE AT ALL SPRINKLER RISERS, DOMESTIC WATER MAIN RISER. AND RAINWATER CONDUCTORS. FOUR -WAY B RAC E REVIEWED FOR CODE COMPLIANCE A PDR fVED DEC 10 2010 citYofrukwila BUILDING DIVISION 3 /8' U -BOLT PIPE RISER 21/2'x2'x3/16 ' ANGLE, LONG LEG VERTICAL BRACE. COPE LEG OF ANGLE 3/6' FILLET WELD (TYPICAL) ALL - AROUND %'Jd EXPANSION ANCHOR (TYPICAL) NOT TO SCALE GRILLES, REGISTERS &DIFFUSERS SCHEDULE M7 EQ� FURNIHED SYMBOL TYPE SERVICE PRICE INDUSTRIES MODEL NO VOLUME DAMPER FRAME FINISH MATERIAL REMARKS C CEILING DIFFUSER SCD 11/2' OR 2' JOSAM 30000 -7A y2. TRAP PRIMER, ROUND STRAINER FD-2 WHITE ENAMEL STEEL 24'x24' MODULAR FULL -FACE DIFFUSER WITH ROUND NECK 1 HALF- GRATE, INTERNAL DOME STRAINER. DO NOT SLOPE FLOOR TO DRAIN. SEE DETAIL 6/P351. FD -3 F RETURN/ TRANSFER GRILLE 80 CORE NONE SEE DETAIL 3/P351. FD -4 WHITE ENAMEL ALUMINUM SEE PLAN FOR FACE SIZE; 1/2' x1/2' x1/2' EGGCRATE GRID. AVAILABLE FACE SIZES ARE 24'x6', 24'x12', 24'x24', & 24'x48'. 1 1 N SUPPLY REGISTER 510D ARCHITECTS PROJECT NO. PRE - SLOPED POLYMER CONCRETE CHANNEL UNITS WITH OVERLAY EDGE PROTECTION RAIL OF DUCTILE IRON AND A C250 SLOTTED DUCTILE IRON GRATE WITH LOCKING MECHANISM. LENGTH OF TRENCH DRAIN SHOWN ON PLANS IS BASED ON USING JOSAM MEADRAIN STANDARD SECTION LENGTH OF 39.4 INCHES. TOP OF GRATE SHALL BE FLUSH WITH FINISHED FLOOR. WHITE ENAMEL STEEL 24'x6' FACE; Y4' BLADE SPACING, SINGLE DEFLECTION, WITH LDE ANGLE PARALLEL RFIXEDL AT 22 5 DEG. SHORT DIMENSION. 1 ALL GRILLES, REGISTERS, & DIFFUSERS ARE FURNISHED BY OWNER AND INSTALLED BY MECHANICAL CONTRACTOR. QUANTITIES, SIZES AND DELIVERY DATES SHALL BE COORDINATED THROUGH THE TARGET REPRESENTATIVE AT 800 - 279 -4087. LAY -IN FRAME TYPE. C PROVIDE DATE ISSUED ISSUES AND REVISIONS FLOOR & ROOF 8 NOVEMBER 2010 11.8.10 - PERMIT SET MODEL NO AND TYPE REMARKS FD -1P DRAWN BY 2', 3' OR 4' 11/2' OR 2' JOSAM 30000 -7A y2. TRAP PRIMER, ROUND STRAINER FD-2 FLOOR SINK D. SCOTT 1%2' OR 2' JOSAM 49300-LF -NB HALF- GRATE, INTERNAL DOME STRAINER. DO NOT SLOPE FLOOR TO DRAIN. SEE DETAIL 6/P351. FD -3 HUB DRAIN WITH STRAINER 3' OR 4' HUB CHECKED BY NONE SEE DETAIL 3/P351. FD -4 TRENCH DRAIN 4' D. BENNETT JOSAM MEADRAIN DI1000 SERIES 1 ARCHITECTS PROJECT NO. PRE - SLOPED POLYMER CONCRETE CHANNEL UNITS WITH OVERLAY EDGE PROTECTION RAIL OF DUCTILE IRON AND A C250 SLOTTED DUCTILE IRON GRATE WITH LOCKING MECHANISM. LENGTH OF TRENCH DRAIN SHOWN ON PLANS IS BASED ON USING JOSAM MEADRAIN STANDARD SECTION LENGTH OF 39.4 INCHES. TOP OF GRATE SHALL BE FLUSH WITH FINISHED FLOOR. n� KInv oryin 1g.g KWH) WATER HEATER SCHEDULE FD DRAIN SCHEDULE FLOOR & ROOF DRAIN NO SERVICE WASTE VENT MODEL NO AND TYPE REMARKS FD -1P GENERAL DRAIN 2', 3' OR 4' 11/2' OR 2' JOSAM 30000 -7A y2. TRAP PRIMER, ROUND STRAINER FD-2 FLOOR SINK 3' OR 4' 1%2' OR 2' JOSAM 49300-LF -NB HALF- GRATE, INTERNAL DOME STRAINER. DO NOT SLOPE FLOOR TO DRAIN. SEE DETAIL 6/P351. FD -3 HUB DRAIN WITH STRAINER 3' OR 4' HUB NONE SEE DETAIL 3/P351. FD -4 TRENCH DRAIN 4' 2• JOSAM MEADRAIN DI1000 SERIES 1 1 PRE - SLOPED POLYMER CONCRETE CHANNEL UNITS WITH OVERLAY EDGE PROTECTION RAIL OF DUCTILE IRON AND A C250 SLOTTED DUCTILE IRON GRATE WITH LOCKING MECHANISM. LENGTH OF TRENCH DRAIN SHOWN ON PLANS IS BASED ON USING JOSAM MEADRAIN STANDARD SECTION LENGTH OF 39.4 INCHES. TOP OF GRATE SHALL BE FLUSH WITH FINISHED FLOOR. KWH) WATER HEATER SCHEDULE NO AREA SERVED LOCATION MFR AND MODEL NO TEMP RISE MAX °F GAL /HR RECOVERY GAL STORAGE INPUT REMARKS y,// -2 /NT & TO TO &ET RM 131 LOCH /NVAR ETN- 040 -ES 65 61 40 NAT C45 33, 000 STUN JANITORS SINK 3' 11/2' 1 - -- X EXISTING TO REMAIN. 1 RECEIVED NOV 19 2010 PERMIT CENTER TARGET STORE SOUTH CENTER WA08.06_,0 301 STRANDER BLVD TUKWILA WA 98188 STORE TO627 PLUMBING FIXTURE SCHEDULE n TITLE PLUMBING & MECH. w FIXT NO SCHEDULES & RISER D IAG RAMS WASTE VENT CW HW FURNISHED BY FLOW REMARKS CONTR OWNER GPM F -6A JANITORS SINK 3' 11/2' - -- - -- X ___ CONDENSATE VACUUM DISCHARGE RECEPTOR NO FAUCET PROVIDED AT THIS FIXTURE THE PIPE SIZE INFORMATION SHOWN IN THIS SCHEDULE 15 INTENDED TO BE THE RUN -OUT OR BRANCH PIPE TO THE FIXTURE IT IS NOT THE ACTUAL PIPE CONNECTION SIZE ON THE FIXTURE. FOR ACTUAL PIPE SIZE AT THE FIXTURE, CONSULT THE PRODUCT CUT SHEET. 1 RECEIVED NOV 19 2010 PERMIT CENTER TARGET STORE SOUTH CENTER WA08.06_,0 301 STRANDER BLVD TUKWILA WA 98188 STORE TO627 VERSION MR2010 _ 08 08- 06- TITLE PLUMBING & MECH. PROJECT CODE 270627 RATION LL SCHEDULES & RISER D IAG RAMS SHEET PM02 NOT USED ////////0001 » 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 NOT TO SCALE 0 0 STOCK ROOM ABOVE FLOOR DEMOLITION PLAN H A R G I S Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz 316" =1' -0" SALES 102 MARKET AREA BELOW FLOOR DEMOLITION PLAN SALES 102 31 6" =1' -0" MARKET AREA ABOVE FLOOR DEMOLITION PLAN DEMOLITION GENERAL NOTES: DEMOLITION 0 ©© KEY NOTES: -DO A. ALL EXISTING PIPING INDICATED ON PLAN WAS TAKEN FROM EXISTING - PERMIT SET ABANDON EXISTING SANITARY SEWER BELOW FLOOR. 1 MECHANICAL PLANS AND /OR FIELD OBSERVATION AND SHALL NOT BE DRAWN BY CONFIGURATION LL D E M O L CONSIDERED 100 PERCENT ACCURATE. CONTRACTOR SHALL VERIFY 2 REMOVE EXISTING HUB DRAIN TO BELOW FLOOR AND CAP. LOCATION OF ALL EXISTING SYSTEMS PRIOR TO CONSTRUCTION AND SHALL NOTIFY THE OSR OF ANY POTENTIAL CONFLICTS. CHECKED BY 3 REMOVE EXISTING VENT TO VENT THROUGH ROOF AND SEAL WATER TIGHT. B. CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS, SPECIFICATIONS & EXISTING CONDITIONS FOR BIDDING PURPOSES. REMOVE AND DISCARD EXISTING CONDENSATE PUMP AND ALL ASSOCIATED q NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS PIPING BACK TO POINT OF DISCHARGE. THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS ARCHITECTS PROJECT NO. KNOWLEDGE. 5 REMOVE EXISTING VENT TO BELOW FLOOR AND CAP. C. PIPING ABANDONED IN PLACE SHALL BE CAPPED, PLUGGED AND CONCEALED. PLUGGING AND CAPPING SHALL BE DONE IN A MANNER 6 NOT USED. AS TO ALLOW REOPENING AND REUSE LATER. 7 EXISTING VENT THROUGH ROOF TO REMAIN. D. PATCHING OF PENETRATIONS WHERE PIPING IS REMOVED SHALL BE BY GENERAL CONTRACTOR. 8 NOT USED. E. CONCRETE CUTS (BY GENERAL CONTRACTOR) SHALL BE STRAIGHT AND 9 CLEAN. REPLACE SLAB WITH CONCRETE FLUSH AND SMOOTH WITH DISCONNECT AND REMOVE EXISTING SUMP PUMPS SP -1 AND SP -2. ADJACENT SURFACE. ABONDON EXISTING SUMP BASIN IN PLACE. PRIOR TO ABANDONMENT, CLEAN BASIN, FILL CAVITY WITH SAND AND PROVIDE CONCRETE SLAB F. FIELD VERIFY LOCATIONS AND QUANTITY OF ALL EXISTING EQUIPMENT, TO MATCH ELEVATION OF SURROUNDING. FIXTURES AND PIPING NECESSARY TO COMPLETE SCOPE OF WORK. G. TO BE REMOVED. REMOVED EQUIPMENT TO /INDICATED BE DISPOSED OF BY CONTRACTOR. PROVIDE OSR & Z/le. REFUSAL FONT REMOVED MANAGEMENT EQUIPMENT. FIRST RIGHT OF H. ARRANGE ALL REQUIRED WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE DISRUPTIONS WITH TARGET OSR AND STORE MANAGER. I. SUBMIT (2) COPIES OF REDLINED AS -BUILT UPDATES. ONE COPY SHALL BE RETAINED AT THE STORE. RETURN A SECOND COPY TO THE OSR TO BE FORWARDED TO THE MECHANICAL ENGINEER. J. CONTRACTOR SHALL COORDINATE ALL PHASES OF DEMOLITION WITH ARCHITECTURAL DEMOLITION PLANS. DATE ISSUED ISSUES AND REVISIONS 8 NOVEMBER 2010 11.8.10 - PERMIT SET TITLE PLUMBING I T I O N PLAN S DRAWN BY CONFIGURATION LL D E M O L D. SCOTT CHECKED BY D. BENNETT ARCHITECTS PROJECT NO. flr h. iw ic.rin 316" =1' -0" REVIEWED FOR- CODE COMPLIANCE A PpRnvEn DEC 10 2010 City of Tukwila Ci o ' la BUILDING DIVigIn,► W91 b-1 SI STOCK ABV FLR FLR DEMO DEMO 11 0— 0- -' I 1 1 1 1 , 1 1 I 1 1 1 I _�__ --,, -� -- - - - - -- -- — -- -- -0 ___3 RECEIVED NOV 19 2010 PERMIT CENTER I:,, 4. Y-5 T m b_ 0_ 0 b - --0 - --0 - 0 -0 -0 - 0 - 0 f 44 :1'#T - -T—� 1 I"I 0 0 0 00 ■ TARGET STORE SOUTH CENTER WA08-06-10 301 STRANDER BLVD TUKWILA WA 98188 t' - STORE T0627 VERSION MR2010_08 TITLE PLUMBING I T I O N PLAN S PROJECT CODE 270627 CONFIGURATION LL D E M O L UNDR ABVT FLR FLR DEMO DEMO - --0 SHEET PDO1 VACUUM COND PUMP 140A cool- r VACUUM COND PUMP 140A - 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 2' J 4'� CO -v I I L EX, C!Y (E)4'J J CO PRODUCE COOLER 183 CO 3, -4' 'PRODUCE ILABELING 184 MEAT COOLER 182 STOCK ROOM UNDERFLOOR PLUMBING PLAN (E14' VTR J HARGI5 Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.harg1s.biz AZ/17 \A /A C_ n\ A /)Lr)7 -7L1 _. 346"= l' -0„ PRODUCE COOLER 183 (EJ 2 1/2' CM PRODUCE LABELING 184 L _ MEAT COOLER 182 STOCK ROOM ABOVE FLOOR PLUMBING PLAN 346"= 1' -0" ............. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 0 2010 CigrofTukwila BUILDING DIVISION PVC SCHEDULE 40 COUPLING WITH STOP PVC PIPE L _ _ CONDENSATE LINES FROM REFRIGERATED CASES PROVIDED BY REFRIGERATION CONTRACTOR AIR GAP PER LOCAL CODE 7— TOP OF HUB TO BE 1' ABOVE FLOOR LINE FINISHED FLOOR SCHEDULE 40 PVC 'HUB FIT' DROP -IN HUB DRAIN STRAINER. GENOVA PRODUCTS MODEL *79230 (3'). MOUNT IN INVERTED POSITION. CONDENSATE DRAIN WITH RAISED HUB (FD -3) BRADLEY CORPORATION MODEL a S19 -270HW WALL MOUNTED EYEWASH. Y2' MIXED WATER (90°F.) GOOSENECK SPOUT %2' MIXED WATER NOT TO SCALE THERMOSTATIC MIXING VALVE --------7 WITH INTEGRAL CHECK VALVES AND LOCKING ADJUSTMENT CAP. INSTALL IN ACCESSIBLE LOCATION IN HAND SINK PEDESTAL. CALIBRATE EYEWASH MIXED WATER TEMPERATURE TO 90° F. 1/2' COLD WATER 1/2' MIXED WATER 1/2' HOT WATER FLOOR MOUNT DOUBLE PEDAL CONTROL VALVE SUPPLY STOPS 1/2' HOT WATER 1/2' COLD WATER THERMOSTATIC MIXING VALVE WITH INTEGRAL CHECK VALVES AND LOCKING ADJUSTMENT CAP. INSTALL IN ACCESSIBLE LOCATION IN HAND SINK PEDESTAL. CALIBRATE OUTLET MIXED WATER TEMPERATURE TO 110° F. HAND SINK MOUNTED EYEWASH PIPING DIAGRAM NOT TO SCALE BRADLEY CORPORATION MODEL * S19 -270HW WALL MOUNTED EYEWASH. GOOSENECK SPOUT PEDESTAL HAND SINK FLOOR MOUNT - DOUBLE PEDAL CONTROL VALVE E• 414 7 74 a= - - n� EYEWASH WATER FLOW IS ACTIVATED BY PULLING SWING ARM DOWN 90° OVER SINK. WATER WILL CONTINUE ■ TO FLOW UNTIL THE ` ARM IS RETURNED TO 11 THE ORIGINAL POSITION. ■ FRONT ELEVATION LEFT ELEVATION HAND SINK MOUNTED EYEWASH NOT TO SCALE HOLD HORIZONTAL DRAIN, VENT AND WATER PIPING MINIMUM 6' ABOVE FLOOR TO ALLOW FLOOR CLEANING FINISHED FLOOR, VERIFY FLOOR COVERING THICKNESS INTERNAL DOME STRAINER FLOOR SINK FD -2 NOT TO SCALE ® EQUIPMENT SYMBOL EQUIPMENT SCHEDULE LEGEND. NUMBER 8 NOVEMBER 2010 FIXTURE WASTE WATER ROUGH-IN HEIGHT AFF REMARKS NO TYPE DIRECT INDIR VENT FCW-F CW HW YE- 0773 EYEWASH - -- - - -- - -- _ -- I /2. I /2 SEE DETAILS 4/13351 AND 5/13351 YE- 0816 1- COMPARTMENT SINK - -- 2' - -- - -- v2. I /2' 12' INDIRECT WASTE TO FLOOR SINK. 0746 HAND SINK 1 I 1/22' - -- 1 I/2' - -- I /2 I /2 . 18: 21 GENERAL NOTES: A. PITCH UNDERFLOOR SANITARY WASTE AND STORM PIPING 3' AND GREATER AT %8' PER FOOT. ALL OTHER WASTE PIPING AT I /4' PER FOOT. B. FIELD VERIFY LOCATION AND INVERTS OF EXISTING UTILITIES. C. WASTE AND VENT PIPING BELOW FLOOR AND THROUGH FLOOR SHALL BE 2' MINIMUM. D. REFER TO PLUMBING EQUIPMENT SCHEDULE ON THIS SHEET FOR INDIVIDUAL BRANCH PIPE SIZES TO FIXTURES AND ROUGH -IN REQUIREMENTS. KEYNOTES: n 2 3 4 0 7 8 9 10 11 2' WASTE UP. 2' VENT UP. NOT USED. 2' VENT DOWN. 1/2' HOT WATER, 11/2' VENT, %2' COLD WATER DOWN. /2' HOT WATER, 2' VENT, %2' COLD WATER DOWN. 11/2' VENT DOWN. SHUT -OFF VALVE. MOUNT IN ACCESSIBLE LOCATION. 3' WASTE UP. PIPE VACUUMN PUMP DISCHARGE TO MOP SINK WITH PROPER AIR GAP. Y2' COLD WATER DOWN TO ACORN VAC SYSTEM. SEE P421 FOR PIPING REQUIREMENTS. PROVIDE SHUT OFF VALVE AND RPZ BACKFLOW PREVENTER. DATE ISSUED ISSUES AND REVISIONS VERSION mum°08 08.06.10 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY D. SCOTT CHECKED BY D. BENNETT ARCHITECTS PROJECT NO. ng Mlnv_'rnn 1g.s`7 X610• UNDR ABV FLR FLR PLBG PLBG 0 - - --0 - - --0 - - --0 —� - -- —H I 1 1 1 1 I I 1 I 1 1 1 RECEIVED NOV 4 9 PERMIT CENTE . 1 ��7�1 © 0 0 4 - --0 0 0 0 0 00 KEY PLAN NOT TO SCALE TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION mum°08 08.06.10 TITLE STOCK ROOM PROJECT CODE 270627 CONFIGURATION LL PLUMBING PLANS SHEET P351 .. .. . .. _ .............. _ ........ _. ...................... REVIEWED FOR CODE COMPLIANCE DDRfVEf DEC 10 2 itl City of Tukwila BUILDING f IVIRIfl i MARKET AREA CONDENSATE VACUUM ABOVE FLOOR PLUMBING 316" = 1' -0" 0 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J i U CV PUMP SCHEDULE NO DESCRIPTION LOCATION MFR & MODEL NUMBER OF LIFT KITS HP VOLT /PH FLA REMARKS CV -1 CONDENSATE VACUUM SKID COND VAC ROOM ACORN VAC AV- 30S -2.2 31 2 (2 HP) 208/3 15.4 OWNER FURNISHED CHECKED BY HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz CONDENSATE VACUUM ABOVE FLOOR PLUMBING Ill 6" = 1' -0" GENERAL NOTES: KEY NOTES: 4• CONTRACTOR SHALL COORDINATE WITH CASE MANUFACTURER AND SPECIFIC INSTALLATION REQUIREMENT FOR FINAL POINTS OF CONNECTION AND PIPE ROUTING THRU THE CASEWORK. B. PLUMBING CONTRACTOR SHALL COORDINATE INSTALLATION OF VACUUM PIPING WITH REFRIGERATION CONTRACTOR PRIOR TO REFRIGERATED CASE INSTALLATIONS. C. ALL CONDENSATE PIPE BRACING AND INSTALLATION REQUIREMENTS MUST COMPLY WITH DETAILS ON SHEET P441 AND P451. D. ALL PIPING, INSTALLATION AND INSTALLATION MATERIALS BY PLUMBING CONTRACTOR. CONDENSATE VACUUM PIPING SHALL BE SCHEDULE 40 PVC PRESSURE PIPE WITH DWV FITTINGS AT CHANGE OF DIRECTION FROM VERTICAL TO HORIZONTAL. E. REMOVE ANY DEBRIS FROM INSIDE REFRIGERATED CASES. FLUSH OUT ALL PIPING AND DRAINAGE SYSTEMS PRIOR TO CONNECTION TO EQUIPMENT. F. ALL HORIZONTAL CONDENSATE PIPING IN STOCK ROOM SHALL BE INSTALLED A MINIMUM OF 16' -0' A.F.F. 0 n 4 5 6 0 8 11/2' CONDENSATE VACUUM PIPING DOWN IN FALSE COLUMN. 11/2' CONDENSATE VACUUM PIPING DOWN IN FRAMED WALL. ACORN CONDENSATE VACUUM SKID, MODEL AV- 30S- 2.2 -LR. PIPE DISCHARGE TO MOP SINK WITH PROPER AIR GAP. ANCHOR LOWER MAIN TO BACK OF CASES. SECONDARY LIFT TO BE LOCATED IN FALSE COLUMN. INSTALLER TO COORDINATE LOCATION WITH GENERAL CONTRACTOR. ANCHOR LOWER MAIN TO WALL. PROVIDE SLOPE MAKE UP TRANSITIONS AS REQUIRED. HORIZONTAL CONDENSATE PIPING AND CONTROL VALVES SHALL BE LOCATED LOW ENOUGH ON THE CASE TO BE HIDDEN FROM SIGHT BY THE DRY SHELVING BACKER BOARD. PROVIDE BELOW FLOOR VACUUM PIPING. F91 DOWN TO WALL MOUNTED ACCUMULATOR. SEE DETAIL 4/P421. 10 CONNECT TO RUNNING TRAP PROVIDED BY CASE MANUFACTURER AND INSTALLED BY REFRIGERATION CONTRACTOR, TYPICAL. SEE 1/P411 FOR CONTINUATION. DATE ISSUED ISSUES AND REVISIONS VERSION MR201008 08-06-10 8 NOVEMBER 2010 11.8.10 - PERMIT SET 4 DRAWN BY D. SCOTT CHECKED BY D. BENNETT ARCHITECTS PROJECT NO. i /1 r •, r11 1 A Al A 9 r r ABOVE FLOOR PLUMBING T 1 2' VAC • `co U 1 1 7 - - 7 �6(o -isq T RECEIVED 0---- - - - - -- NOV 19 2010 PERMIT CENTER 1 1 1 1 1 1 ---- 1--- -1---- 1-- -J-- -I 1 1 1 1 1 1 I 1 1 I I 1 1 I I I .1' I I I --0 --0 -0 --0 -® --0 --0 --0 - -0 0 - - —I - — - , 0 0 ABOVE FLOOR PLUMBING ABOVE FLOOR PLUMBING ■ TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR201008 08-06-10 1 TITLE CONDENSATE VAC U U M PROJECT CODE 270627 CONFIGURATION LL PLANS - 4 --0 -0 KEY PLAN NOT TO SCALE SHEET P411 TOP OF REFRIGERATED CASE 1-1/2" PRESSURE RATED PIP) TYPICAL SENSOR PIPE 1 -1/2" PIPE ACCUMULATOR PROVID BY CONTRACTOR. TYPICAL. SEE DETAIL "E" ON SHVT P431. .%_l— CONTROLLER ICI! =II III ►, \� 1/4" PER FOOT EXTRACTION PIPE SLOPE VALVE ,11 III��� `� •II_I�I ■.IN \II I 11► / • / / CLEAN —OUT EXTEND ONE AIR INTAKE FOR EACH ACCUMULATOR ABOVE TOP OF CASE. USE A WASTE FITTING AT THE BASE FOR CLEANOUT ACCESS. / / 1/4" PER FOOT PIPE SLOPE / �II�1 ■Ili II.I ■1111.1 ■. NOTES: 1. ALL COMPONENTS SHALL BE ACCESSIBLE FOR SERVICING. 2. EXTRACTION VALVES, CONTROLLERS, AND SWING CHECK VALVES SUPPLIED BY OWNER AND INSTALLED BY CONTRACTOR. 3. REFER TO DETAILS ON SHEET P431 FOR ADDITIONAL INFORMATION. 4. HEIGHT OF TWO AIR INTAKES MUST BE LOWER THAN THE INLET OF ANY DRAINS IT IS CONNECTED TO. —0" MAX. 2" SWING CHECK VALVE OWNER FURNISHED, INSTALLED BY PLUMBING CONTRACTOR. —0" MAX. 1 1/2" ISOLATION VALVE ABOVE ACT CEILING ACT CEILING 1 1/2" PRESSURE RATE-B---___> PIPE RISER RATED PIPE RISER BY PLUMBING CONTR. 2" PRESSURE RATED PIPE PLUMBING CONTRACTOR (TYPICAL). ■ `ICI 1' I: L�I:III TYPICAL TWO STAGE, MULTI —CASE, END DISCHARGE, LIFT NOT TO SCALE 1/4" PER FOOT CLEAN —OUT OVERHEAD MAIN TO VACUUM CENTER MUST BE 16 FEET ABOVE FINISHED FLOOR OR GREATER. SEE PIPING PLAN FOR PRESSURE RATED PIPE SIZE, BY PLUMBING CONTRACTOR. �- REFRIGERATED CASE TYPICAL REFRIGERATED CASE MAIN DRAIN LINE REFRIGERATED CASE 1 1 /2" PIPE DOWN TO PIPE ACCUMULATOR. TYPICAL. REFRIGERATED CASE EXTRACTION VALVE TYPICAL REFRIGERATED CASE TOP VIEW OF CASES L - CHECK VALVE NOT TO SCALE NOT USED WASTE EXTRACTION VALVE — FURNISHED BY ACORNVAC, INSTALLED BY CONTRACTOR. IN —LINE MINI CHECK VALVE — FURNISHED BY ACORNVAC, INSTALLED BY CONTRACTOR. MUST BE 4" ABOVE VACUUM SOURCE PORT. VACUUM SOURCE Y4" I.D. FLEXIBLE RUBBER TUBE — FURNISHED BY ACORNVAC, INSTALLED BY CONTRACTOR. REQUIRED FULL PORT ISOLATION VALVE — SUPPLIED BY INSTALLING CONTRACTOR. REMOVABLE BANDED COUPLINGS — SUPPLIED BY INSTALLING CONTRACTOR. EXTRACTION VALVE Y4" I.D. FLEXIBLE RUBBER TUBE — FURNISHED BY ACORNVAC, INSTALLED BY CONTRACTOR. WIRE TIES. DO NOT OVERTIGHTEN. (TYPICAL) AIR INTAKE. AIR GAP IN ACCORD WITH LOCAL CODE. 12" RISER. 2" x 12" REDUCER. PNEUMATIC CONTROLLER — FURNISHED BY ACORNVAC, INSTALLED BY CONTRACTOR. ACCUMULATOR SENSOR Y4" I.D. FLEXIBLE RUBBER TUBE — FURNISHED BY ACORNVAC, INSTALLED BY CONTRACTOR. TUBE MUST NOT DIP BELOW TOP OF ACCUMULATOR OR CONTAIN ANY TRAPS. rJ CONDENSATE DRAIN FROM COILS — PIPE TO ACCUMULATOR BY INSTALLING CONTRACTOR. 13 " +1" 192 " ±1" x 2" x 12" WYE. PIPE ACCUMULATOR. FLOOR WALL MOUNTED COIL PIPE ACCUMULATOR FOR WALK —IN COOLER AND FREEZER NOT TO SCALE a II 1/2" r ►.I ■ WATER INLET CLEAR BODY SEDIMENT FILTER (BY PLUMBING CONTR.) SIDE VIEW OF TYPICAL WATER CONNECTION WATER INLET WATER OUTLET RPZ BACKFLOW PREVENTOR (BY PLUMBING CONTR.) NOTE: OPERATING LINE PRESSURE 80 PSIG, MAX. 30 PSIG, MIN. PIPING FOR MAKE -UP WATER LINE AND MANUAL DRAINS BY PLUMBING CONTRACTOR. I3a PUMP I PULP 2 FLEXIBLE SUPPLY CONNECTION (BY PLUMBING CONTR.) AIR GAP PER CODE REQUIREMENTS — MANUAL DRAIN - TYPICAL (BY PLUMBING CONTR.) DISCHARGE FRO VACUUM CENTER CONNECT TO DRAIN LINE GRAVITY SEWER FLEXIBLE OUTLET CONNECTION (BY PLUMBING CONTR.) 24" x 36" x 8" DP MOP SINK WITH 3" OUTLET — BY PLUMBING CONTRACTOR WASTE DRAIN DETAIL 65 1/2" FIR ww A]jPArii'1■1 60 1/2" REVIEWED FOR CODE COMPLIANCE A PPRfVED DEC 1 0 2010 City of Tukwila 1 BUILDING DIVISION 11 36 1/2" 22" 18 1/2" 27" 3/4" DIAMETER ANCHORING HOLES — EIGHT PLACES DRAIN OUTLET TO GRAVITY SEWER 3" PVC PIPE SOCKET CONNECTION 17 1/2" I= I!II11 2" SWING CHECK VALVE AND 2" SHUTOFF VALVE SUPPLIED LOOSE BY ACORNVAC FOR INSTALLATION BY OTHERS IN EACH TANK WASTE INLET LINE. MOUNTING FOOT PRINT DETAIL RECOMMENDED ANCHORING IS WITH BOLTS AND WEDGE CONCRETE ANCHORS 3/8" DIA. x 2 -1/4" L .32" CONTROL PANEL 2X — 2HP PUMP 2" BUILDING WASTE INLET ON TOP OF TANK (TYPICAL) AV- 30S- 2.2 —LR —SE —MOD VACUUM CENTER WITH OUTLET TO 24 "x 36" MOP SINK NOT TO SCALE ISLAND CASE (TYPICAL) —\ OVERHEAD MAIN TO VACUUM CENTER MUST BE 16 FEET ABOVE FINISHED FLOOR OR GREATER — SEE PIPING PLAN DRAWING FOR PRESSURE RATED PIPE SIZE, BY PLUMBING CONTR. 2" SWING CHECK VALVE — SUPPLIED B OWNER, INSTALLED BY PLUMBING CONTR. 2" PRESSURE RATED PIPE 1/4" PER FOOT 7' —O" MA CLEAN —OUT 1 1/2" ISOLATION VALVE ABOVE ACT CEILING BY PLUMBING CONTR. TYP. ACT CEILING ISOLATION VALVE BY INSTALLING PLUMBING CONTRACTOR. LOWER MAIN OF TWO STAGE MULTI —CASE LIFT EXTRACTION VALVE, CONTROLLER AND PLASTIC BOX ACCUMULATOR — SUPPLIED BY ACORNVAC, INSTALLED BY CONTRACTOR. NOTE: COMPONENTS MUST BE ACCESSIBLE FOR SERVICE. 1 \olio • V____ • ■ n\ Ahl.k iili't 1 -1/2" PRESSUR/ RATED PIPE RISER 1/4" PER FOOT NN— 1-1/2" PRESSURE RATED PIPE RISER CASE TRAP (TYPICAL) AIR INTAKE TEE (TYPICAL) 1/4" PER FOOT COLLECTOR POCKET 2" PRESSURE RATED PIPE BY PLUMBING CONTRACTOR. BELOW FLOOR VACUUM PIPING TWO STAGE LIFT DETAIL NOT TO SCALE ?&IO*b (57 RECEIVED NOV 19 2010 PERMIT CENTER 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 H A R G I S Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T: \Remodels \0627 WA South Center R\ ActiveCAD \0627p421.dan DATE ISSUED 8 NOVEMBER 2010 ISSUES AND REVISIONS VERSION mum 08 08-06-10 11.8.10 - PERMIT SET DRAWN BY D. SCOTT CHECKED BY D. BENNETT ARCHITECTS PROJECT NO. 05 —NOV -2010 15:52 TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION mum 08 08-06-10 TITLE CON D E N SAT E VAC U U M DETAILS PROJECT CODE 270627 CONFIGURATION LL SHEET P421 INSTALLATION NOTES FOR VACUUM DRAINAGE PIPING: 1. PRESSURE RATED PVC PIPE AND DWV PATTERN FITTINGS ONLY TO BE USED ON VACUUM SYSTEM. 2. PITCH VACUUM DRAINAGE PIPING AT A MINIMUM �4" PER FOOT. 3. VACUUM DRAINAGE RISER MUST ENTER MAINS FROM ABOVE USING A WYE FITTING. THE WYE FITTING MAY BE ROLLED 45r' FROM VERTICAL. 4. NO TEE FITTINGS ARE PERMITTED IN THE VACUUM DRAINAGE PIPING. 5. INSIDE PIPING SURFACES AND JOINTS MUST BE SMOOTH, FREE OF BURRS AND OBSTRUCTIONS. 6. LOCATE CLEAN OUTS IN THE VACUUM DRAINAGE PIPING AT THE ENDS OF MAINS AND BRANCHES, AND WHEN THERE IS A 90"' CHANGE IN DIRECTION IN THE OVERHEAD BRANCH OR MAIN. 7. A SINGLE OFFSET IS ALLOWED IN VERTICAL RISERS. OFFSET IS NOT PREFERRED AND SHALL ONY BE USED TO BYPASS STRUCTURAL OBSTRUCTIONS. 8. ISOLATION AND CHECK VALVES SHALL BE FULL PORT VALVES. 9. USE ONE DWV LONG SWEEP it4 BEND WHEN THERE IS A 90^, CHANGE IN DIRECTION. 10. LAYOUT ILLUSTRATES GENERAL PIPING ARRANGEMENT. CONTRACTOR TO COORDINATE WITH GENERAL CONTRACTOR AND SPECIFIC INSTALLATION REQUIREMENTS FOR FINAL POINTS OF CONNECTION AND PIPE ROUTING. VACUUM DRAINAGE PIPING NOTES NA CONNECTION TO LIFT OR BRANCH MAIN x� CONNECTION OF LIFT OR BRANCH TO MAIN NOT TO SCALE VIEW X —X MAXIMUM PERMISSIBLE ROTATION ANGLE OF WYE, TO FACILITATE CONNECTION TO LIFT AND BRANCH MAINS. 1/4" SLOPE MAINS OR BRANCHES 1/4" PER 12" El!:///r- FLOW ) TO VAC CENTER SLOPE J TYPICAL SLOPE DETAIL 12" NOT TO SCALE SLOPE MAKE UP DETAIL FLOW NOT TO SCALE NOTES: 1. FLEXIBLE RUBBER TUBE MUST BE ATTACHED TO EXTRACTION VALVE CLIP. 2. CONTROLLER MUST BE INSTALLED IN AN ACCESSIBLE LOCATION. 3. APPROPRIATE PIPE BRACING MUST BE 12" (305mm) AWAY FROM EXTRACTION VALVE ON BOTH SIDES TO ALLOW COUPLINGS TO SLIDE FREELY. 4. TOP OF EXTRACTION VALVE MUST BE INSTALLED EVEN WITH TOP OF CASE AND CLEARANCE MUST BE PROVIDED TO ALLOW FOR UNOBSTRUCTED MOVEMENT. 5. MINI CHECK VALVE MUST BE 4" ABOVE VACUUM SOURCE PORT WHEN X -VALVE IS MOUNTED HORIZONTALLY AND 12" ABOVE VACUUM SOURCE PORT WHEN MOUNTED IN THE VERTICAL POSITION. 6. THE CONNECTION FROM THE ACCUMULATOR SENSOR PORT TO THE CONTROLLER MUST NOT DIP BELOW TOP OF ACCUMULATOR OR CONTAIN ANY TRAPS. 24" MAX TOP OF REFRIGERATED CASE MINI CHECK VALVE - SEE NOTE # EXTRACTION VALVE - SEE NOTE # 3 AND # FLEXIBLE RUBBER COUPLINGS PIPE BRACING - SEE NOTE # 3. 1/4" ID FLEXIBLE RUBBER TUBE CONTROLLER - OWNER FURNISHED SEE NOTE # 2. 0 1/4" ID FLEXIBLE RUBBER TUBE TO CONTROLLER - OWNER FURNISHED, SEE NOTE # 6. WHEN ACCUMULATOR IS CONCEALED AND NOT SERVICEABLE, EXTEND SENSOR PORT AND FURTHEST AIR INTAKE TO TOP OF OF CASES AND USE A WASTE FITTING AT THE BOTTOM OF AIR INTAKE FOR CLEANOUT ACCESS. SENSOR PIPE EXTEND AIR INTAKE TO MATCH ELEVATION OF CASE DRAIN OUTLET -1/2" LIFT BRACING (TYPICAL) CONDENSATE • °. 4 ' ( °• .4 A° .. n TYPICAL PIPE ACCUMULATOR CONNECTION NOT TO SCALE .4 1 -1 /2" PIPE d :4 . 4 4. I1' 1 2" 48" MAX. 4. L1 ' . 12" 1COD VIEWED FOR APpOMPLlgNCE DEC 10 2010 City of Tukwila BUILDING Dwic,nh, NOT TO SCALE CLEAN OUT REQUIRED 36" MAX MAINTAIN SLOPE 7' -0" MAX.) OBSTRUCTIONS OFFSET ACCUMULATOR 1 2" HORIZONTAL MAX FLOW OFFSET f OFFSETS IN EXCESS OF 12" MUST RUN HORIZONTALLY WITH SLOPE INTO COLLECTION POCKET BEFORE RESUMING LIFT. ACCUMULATOR ROUTING AROUND HORIZONTAL 8e VERTICAL OBSTRUCTIONS NOT TO SCALE ALL PIPING MUST BE SUPPORTED, BRACED AND SECURED TO RESIST THRUSTING FORCES AND MINIMIZED MOVEMENT. ALL PIPING MUST BE BRACED PER ACORNVAC SPECS OR PER LOCAL CODE REQUIREMENTS WHICHEVER IS MORE RESTRICTIVE. ALL BRACING ASSEMBLIES MUST BE ATTACHED TO STRUCTURAL STEEL, RIGID STUDS, OR WOODEN BACKINGS. DRYWALL AND HVAC DUCT WORK ARE NOT ACCEPTABLE ANCHOR POINTS. BRACING OF HORIZONTAL PIPING SHOULD BE IN FOUR FOOT INTERVALS WHEN INSTALLATION IS DONE IN PVC, AND EIGHT FOOT INTERVALS FOR COPPER, OR AS REQUIRED BY LOCAL CODE. SAGGING OF THE PIPING BETWEEN SUPPORTS IS NOT PERMITTED; 1/4" PER FOOT OF SLOPE IS TO BE MAINTAINED AT ALL TIMES. LATERAL OR SEISMIC BRACING SHOULD BE ADDED EVERY 25' OR AS REQUIRED BY LOCAL CODE WHICHEVER IS MORE RESTRICTIVE. WHEN A UNI -STRUT TRAPEZE IS USED, PIPING MUST BE CLAMPED DOWN SECURELY. VERTICAL LIFTS ARE TO BE SECURED IN SIX FOOT INTERVALS. BRACING IS REQUIRED AT THE TOP OF ALL VERTICAL LIFTS TO PREVENT HORIZONTAL AND LATERAL MOVEMENT. AN APPROVED BRACING ASSEMBLY MUST BE INSTALLED WITHIN ONE FOOT OF EVERY DIRECTIONAL CHANGE, ON BOTH SIDES OF THE FITTING. AN APPROVED BRACING ASSEMBLY MUST BE INSTALLED WITHIN ONE FOOT OF EVERY EXTRACTION VALVE, ON BOTH THE INLET AND THE OUTLET SIDE. BEAM CLAMP WITH ALL THREAD & SPLIT RING HANGER PIPE STAND a* o • • a O • '4 6 0 • ° a a a,° • a • °,• a • 'a a0 • e a Q `' q 4 ."p' STRUT & STRUT CLAMPS TYPICAL BRACING DETAILS NOT TO SCALE 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz i T: \Remodels \0627 WA South Center R\ ActiveCAD \0627o431.dan DATE ISSUED ISSUES AND REVISIONS / 8 NOVEMBER 2010 11.830 - PERMIT SET TITLE CONDENSATE VACUUM PROJECT CODE 270627 CONFIGURATION LL DRAWN BY D. SCOTT CHECKED- BY D. BENNETT ARCHITECTS PROJECT NO. ■ 05 -NOV -2010 15:52 ANGLE BRACKET WITH ALL THREAD & SPLIT RING HANGER WELDED BRACKET TRAPEZE WITH STRUT & STRUT CLAMPS RECEIVED NOV 19 2010 PERMIT CENTER o s SHEET P431 i TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TU KWI LA WA 98188 STORE T062 7 VERSION MR2010_08 08-06-10 TITLE CONDENSATE VACUUM PROJECT CODE 270627 CONFIGURATION LL DETAILS SHEET P431 .- 7 .., -. A. :,/ (!A • /`5- -� / 6 - -_- --1 ::*4 Ir471411114 klartiNaNt t . ,. .11VII bit& 11- - - if 1 II II If 11 II >- -rr J 1 11 11 11 11 11 11 R 11 11 I II. : : . . . : . . I I . .. . . . . . . . 11.......... If 11 It 11 R 11 R 11 11 I 0 R -7 -/ , / -t ti ...I�r -i I _ f .- �1I R r� }I T R 11 R 11 11 IL / 11 1 `e I s11 !.I... 5 MARKET AREA HVAC DEMO PLAN 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 H A R G I S ■ Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.b1z T: \Remodels \0627 WA South Center R\ ActiveCAD 0627m111.dgn V8" =1' -0" DEMOLITION GENERAL NOTES: A. ALL EXISTING DUCTWORK INDICATED ON PLAN WAS TAKEN FROM EXISTING MECHANICAL PLANS AND /OR FIELD OBSERVATION AND SHALL NOT BE CONSIDERED 100Y ACCURATE. THE CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING SYSTEMS PRIOR TO CONSTRUCTION AND SHALL NOTIFY THE OSR OF ANY POTENTIAL CONFLICTS. B. CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS, SPECIFICATIONS & EXISTING CONDITIONS FOR BIDDING PURPOSES. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. C. PATCH ALL PENETRATIONS WHERE PIPING OR DUCTWORK IS REMOVED. PATCHING SHALL BE BY GENERAL CONTRACTOR. D. FIELD VERIFY LOCATIONS AND QUANTITY OF ALL EXISTING EQUIPMENT, FIXTURES AND DUCTWORK NECESSARY TO COMPLETE SCOPE OF WORK. F. INDICATED TO BE REMOVED. REMOVED EQUIPMENT TO BE DISPOSED OF BY CONTRACTOR. PROVIDE O5R & TARGET FACILITIES MANAGEMENT FIRST RIGHT OF REFUSAL ON REMOVED EQUIPMENT. PROVIDE OSR & TARGET FACILITIES MANAGEMENT FIRST RIGHT OF REFUSAL ON DEMO'D EQUIPMENT. Imo-- INDICATES EXISTING CONDITIONS. > I; I TYPICAL TEXT OF EXISTING CONDITIONS. CONTRACTOR " -1 I SHALL VERIFY ALL EXISTING CONDITIONS. RTU G. ARRANGE ALL REQUIRED WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE ANY DISRUPTIONS WITH TARGET OSR AND STORE MANAGER. H. SUBMIT (2) COPIES OF REDLINED AS -BUILT UPDATES. ONE COPY TO BE RETAINED AT THE STORE. RETURN SECOND COPY TO THE OSR TO BE FORWARDED TO THE MECHANICAL ENGINEER. I. CONTRACTOR SHALL COORDINATE ALL PHASES OF DEMOLITION WITH ARCHITECTURAL DEMOLITION PLANS. DEMOLITION KEY NOTES: n 2 3 4 5 6 RELOCATE EXISTING 48x48 SUPPLY DIFFUSER, REFER TO M111 FOR NEW LOCATION. PREPARE EXISTING SUPPLY DUCT FOR CONNECTION TO NEW DUCTWORK SHOWN ON M111. REMOVE AND DISCARD EXISTING DUCT. ASSOCIATED HANGERS, GRILLES, AND DIFFUSERS TO LOCATION SHOWN. PREPARE EXISTING SUPPLY DUCT FOR CONNECTION TO NEW DUCTWORK SHOWN ON M111. REMOVE AND DISCARD EXISTING DUCT, ASSOCIATED HANGERS, AND GRILLES TO LOCATION SHOWN. PATCH AND SEAL DUCT AIR TIGHT. REMOVE AND DISCARD EXISTING TEMPERATURE SENSOR. REFER TO M111 FOR NEW LOCATION. EXISTING TO REMAIN. REMOVE AND DISCARD EXISTING DUCT, ASSOCIATED HANGERS. AND DIFFUSERS TO LOCATION SHOWN. PATCH AND SEAL DUCT AIR TIGHT. 6 ?, _ • • �,.... /• I- . s' - - - - -- v 4, 24x6 305 1_- , RT 101)) J TYP. 11 11 >11 II 11 n - % 1 X11 • .r , 1 11 11 11 1 11 11 11 n 11 11 R 1 R 11 C P 1 4.„1f < ` i♦ - - 1 MARKET AREA HVAC NEW WORK PLAN DATE ISSUED ISSUES AND REVISIONS VERSION MR201008 8 NOVEMBER 2010 11.8.10 - PERMIT SET BALANCING DAMPER. HVAC MARKET TEMP. AND HUMIDITY SENSOR. MOUNT ON COLUMN 96' AFF. MOUNT ON SAME COLUMN AS REMS MARKET TEMP. AND HUMIDITY SENSOR. 2 DRAWN BY REMS SENSOR INSTALLED BY DIVISION 24. 3 CONNECT TO EXISTING 60x20 SUPPLY DUCT. D. SCOTT 4 SUPPLY REGISTER LOCATED TO PREVENT INTERFERENCE WITH REFRIGERATED CASE AIR CURTAINS. CENTER IN AISLE. CHECKED BY 5 CONNECT TO EXISTING SUPPLY DUCT. FIELD VERIFY EXISTING SIZE. D. BENNETT EXISTING DIFFUSER, REBALANCE TO 1.000 CFM. 7 CONNECT NEW DUCT TO EXIST. RETURN DROP. FIELD VERIFY EXISTING SIZE. ARCHITECTS PROJECT NO. / - - - ■ 05 —NOV -2010 15:52 V8" =1' -0" 4 NEW WORK GENERAL NOTES: A. VERIFY CEILING LAYOUT PRIOR TO FABRICATING DUCT RUNS AND DROPS. B. SEE SHEET PM02 FOR GRILLES, REGISTERS, AND DIFFUSERS SCHEDULE. C. SEE SHEET PM01 FOR TYPICAL PIPE AND DUCT HANGER DETAILS. VERSION MR201008 NEW WORK KEYNOTES: 11 PROJECT CODE 270627 CCONFFIIG RATION LL 1 BALANCING DAMPER. HVAC MARKET TEMP. AND HUMIDITY SENSOR. MOUNT ON COLUMN 96' AFF. MOUNT ON SAME COLUMN AS REMS MARKET TEMP. AND HUMIDITY SENSOR. 2 REMS SENSOR INSTALLED BY DIVISION 24. 3 CONNECT TO EXISTING 60x20 SUPPLY DUCT. 4 SUPPLY REGISTER LOCATED TO PREVENT INTERFERENCE WITH REFRIGERATED CASE AIR CURTAINS. CENTER IN AISLE. 5 CONNECT TO EXISTING SUPPLY DUCT. FIELD VERIFY EXISTING SIZE. 6 EXISTING DIFFUSER, REBALANCE TO 1.000 CFM. 7 CONNECT NEW DUCT TO EXIST. RETURN DROP. FIELD VERIFY EXISTING SIZE. SEE PLANS FOR SEE PLANS FOR _ NECK SIZE NECK SIZE GRILLE OR REGISTER BELOW 12x12 OR 24x24 NOTE: MAXIMUM OF 18' OF FLEX DUCT MAY BE USED FOR FINAL CONNECTION O— -I— - — - 0— 6x24 OR 12x24 GRILLE & REGISTER BOOT DETAIL REVIEWED FOR CODE COMPLIANCE A PORn V D DEC 1 0 2010 City of Tukwila BUILDING DIVI If N 1)G10 -I59 T I GRILLE OR REGISTER BELOW NOT TO SCALE I T Pirii - - --0 - --0 -- --0 1 :! 0- - - - - -- RECEIVED NOV 19 2010 PERMIT CENTER 1 1 -- 1 - - - -�- —�- _ 1 _ 1 1 1 1 I I I 11 • I 111 , _ m _ I 1 I– I 0 0 0 0 KEY PLAN 0 00 NOT TO SCALE ■ TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 7 STORE T0627 VERSION MR201008 TITLE MARKET AREA HVAC DEMO & NEW WORK PROJECT CODE 270627 CCONFFIIG RATION LL PLANS I HVAC HVAC DEMO NEW SHEET Mill OFFICE AREA HVAC DEMO PLAN 0 0 ROOF HVAC DEMO PLAN DEMOLITION GENERAL NOTES: A. ALL EXISTING DUCTWORK INDICATED ON PLAN WAS TAKEN FROM EXISTING MECHANICAL PLANS AND /OR FIELD OBSERVATION AND SHALL NOT BE CONSIDERED 100% ACCURATE. THE CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING SYSTEMS PRIOR TO CONSTRUCTION AND SHALL NOTIFY THE OSR OF ANY POTENTIAL CONFLICTS. B. CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS. SPECIFICATIONS & EXISTING CONDITIONS FOR BIDDING PURPOSES. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. C. PATCH ALL PENETRATIONS WHERE PIPING OR DUCTWORK IS REMOVED. PATCHING SHALL BE BY GENERAL CONTRACTOR. D. FIELD VERIFY LOCATIONS AND QUANTITY OF ALL EXISTING EQUIPMENT, FIXTURES AND DUCTWORK NECESSARY TO COMPLETE SCOPE OF WORK. E. F . 1 INDICATED TO BE REMOVED. REMOVED EQUIPMENT TO BE DISPOSED OF BY CONTRACTOR. PROVIDE OSR & TARGET FACILITIES MANAGEMENT FIRST RIGHT OF REFUSAL ON REMOVED EQUIPMENT. PROVIDE OSR & TARGET FACILITIES MANAGEMENT FIRST RIGHT OF REFUSAL ON DEMO'D EQUIPMENT. 'k INDICATES EXISTING CONDITIONS. '-AF 11 1)0 11 RTU TYPICAL TEXT OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. G. ARRANGE ALL REQUIRED WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE ANY DISRUPTIONS WITH TARGET OSR AND STORE MANAGER. H. SUBMIT (2) COPIES OF REDLINED AS-BUILT UPDATES. ONE COPY TO BE RETAINED AT THE STORE. RETURN SECOND COPY TO THE OSR TO BE FORWARDED TO THE MECHANICAL ENGINEER. I. CONTRACTOR SHALL COORDINATE ALL PHASES OF DEMOLITION WITH ARCHITECTURAL DEMOLITION PLANS. DEMOLITION KEY NOTES: 1 El 3 REMOVE AND DISCARD EXISTING DUCT. ASSOCIATED HANGERS. GRILLES. AND DIFFUSERS. REMOVE AND DISCARD EXISTING RTU -17 ASSOCIATED GAS PIPING AND CONTROLS. EXISTING EXHUAST SYSTEM TO REMAIN. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 1i8" =1' -0" 0 _4 1B" =1' -0" O 1 NEW WORK GENERAL NOTES: VERIFY CEILING LAYOUT PRIOR TO FABRICATING DUCT RUNS AND DROPS. COORDINATE LOCATIONS OF GRILLES, REGISTERS AND A. DIFFUSERS IN CEILINGS WITH ARCHITECTURAL REFLECTED CEILING PLAN. B. FOR GRILLES, REGISTERS AND DIFFUSERS SCHEDULE, SEE SHEET PM02. C. REFER TO SPECIFICATION FOR DUCT INSULATION REQUIREMENTS. D. BRANCH TAKE -OFFS TO DIFFUSERS ARE TO BE THE SAME DIAMETER AS THE DIFFUSER NECK UNLESS NOTED OTHERWISE. E. LOCATE ALL BALANCING DAMPERS AT 1' -0' ABOVE THE CEILING. F. FOR TYPICAL FLEXIBLE CONNECTION TO DIFFUSER, SEE 3/M331. G. SEE SHEET PM01 FOR TYPICAL PIPE AND DUCT HANGER DETAILS. NEW WORK KEYNOTES: 1 2 F4-1 5 8 BALANCING DAMPER. MOUNT BOTTOM OF EQUIPMENT AT 1' -0' ABOVE FINISHED CEILING. MAINTIAN REQUIRED CLEARANCE TO SIDE OF BOX ROOFTOP UNIT PIPED CONDENSATE IF REQUIRED SHOULD BE PIPED TO ROOF DRAINS. BALANCING DAMPER LOCATED IN ACCESSIBLE LOCATION ( + / -) 1' -0' ABOVE CEILING. SUPPLY AND RETURN DUCTS UP TO RTU. ADJUST DIFFUSER THROW TOWARDS WINDOW OR DOOR. TEMPERATURE SENSOR, MOUNT AT 60' AFF. THERMOSTAT, MOUNT AT 60' AFF. I o I GAS CONNECTION TO ROOFTOP UNIT. GAS PIPING SHALL NOT INTERFER WITH I ' I OPENING OF ACCESS DOORS OR LIMIT DOOR SWING NECESSARY FOR DOOR HOLD OPENS PROVIDED WITH UNIT. 10 11 GAS PRESSURE REGULATOR. GAS SHUTOFF VALVE. i HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.harg1s.biz T: \Remodels \0627 WA South Center R\ ActiveCAD \0627m331.don PROVIDE SUPPORTS TO PREVENT SAG BETWEEN HANGERS HARD DUCT - ELBOW TOTAL FLEX DUCT LENGTH SHALL NOT EXCEED 6 FEET DUCT COLLAR CONNECTING STRA DIFFUSER CONICAL SPIN IN WITH DAMPER SUPPLY DUCT MAIN MINIMUM OF ONE DUCT DIAMETER OF STRAIGHT DUCT TO INLET OF DIFFUSER, OR PROVIDE EQUALIZING GRID AT DIFFUSER DIFFUSER FLEXIBLE DUCT CONNECTION SEE PLANS FOR NECK SIZE GRILLE OR REGISTER BELOW SEE PLANS FOR NECK SIZE 12x12 OR 24x24 NOTE: MAXIMUM OF 18' OF FLEX DUCT MAY BE USED FOR FINAL CONNECTION NOT TO SCALE 6x24 OR 12x24 GRILLE & REGISTER BOOT DETAIL GRILLE OR REGISTER BELOW NOT TO SCALE 1/2'0 BURGLAR BARS 8' ON CENTER ARE INTEGRAL TO CURB HOUSING IN RETURN AIR OPENING. NO BURGLAR BARS IN SUPPLY AIR OPENING. FULL PERIMETER WOOD TACK STRIP 14 GA 14' CURB HOUSING. MOUNT OVER ROOF DECK ON ANGLE FRAME. COORDINATE ANGLE FRAME DIMENSIONS WITH STRUCTURAL. ATTACH FULL SIZE SHEETMETAL DUCT TO SUPPLY AND RETURN CURB OPENINGS. RTU STRUCTURAL CURB (NON -SALES FLOOR UNITS) LENNOX 'B' CABINET CURB 7.5,8.5,10 TON MECHANICAL CONTRACTOR TO INSTALL AES PROVIDED NEOPRENE GASKET AROUND PERIMETER OF CURB RAIL AND AT TOP OF ALL VERTICAL MEMBERS. NOT TO SCALE ©100 175 80 rn 165 (TYP. OF 6) 5 33 (TYP.) 100 175 80C 100 275 80 1 200 - - -VAV HRBP 17 -1 201 I ENCLAVE fi40 DIST. OFFICE LOUNGE 1 CIRC. 80 MENS WOMENS 80 125- DTL VAV 202 17 -2 VAV 17 -9 140 213 214 SWING 203 140 2# 100 100 >12>a ...... OFFICE 2:12 0.1 1 VAV 17 -4 00 80 125 4 1 180 (TYP.) s ROOFTOP CURB GASKETING DETAIL (LENNOX RTU'S /AES CURBS) NOT TO SCALE 1 RTU 1 1E- 1 BRACKET LOCATIONS BRACKET (TYPICAL OF 4) NOTE; •HOLD -DOWN BRACKETS ARE FURNISHED BY AES, RTU ROOF CURB MANUFACTURER. USE EIGHT *10 TEK SCREWS PER BRACKET. BRACKET DIMENSIONS VARY WITH RTU SIZE. RTU HOLD -DOWN BRACKET DETAIL SCREW LOC (TYPICAL 0 .VAV. VAV 7:- 17 -10 CONFERENCE 09 OFFICE 1 - - -2 INVESTIGATION CE EQUIP. 205 DTL 206 1 21 NTEF 100 325 11 VAV 17- 7 ..................... "TTS 21.1A 100 240 125 80 125.. 4x Q 160 200 8 125 OFFICE AREA HVAC NEW WORK PLAN V8" =1' -0" 0 10 11 i v REVIEWED FOR COMPLIANCE ,A aaQfvtl DEC 10 20i8 Hof Tukwila City BUILDING nnninhi, ROOF HVAC NEW WORK PLAN 0 1B" =1' -0" O --4 VARIABLE AIR VOLUME BOX SCHEDULE - OWNER FURNISHED Tag Area Served Price Model No. Inlet Diameter Voltage Primary Air Estimated Sensor Calibration Settings Fan Data Electric Heating Coil Remarks Cooling Min CFM Cooling Max CFM Heating CFM Cooling Min CFM Cooling Max CFM CFM HP FLA Voltage Heating Coil CFM Heating Coil kW Reheat Stages Temp Rise LAT ( °F) VAV -17 -01 HRBP SDV -06 6 277 -1 80 175 100 13 34 ARCHITECTS PROJECT NO. 100 1.0 1 31.6 86.6 Electric Reheat Coil VAV -17 -02 DTUSWING SDV -06 6 277 -1 80 250 100 13 51 100 1.0 1 31.6 86.6 Electric Reheat Coil VAV -17 -03 DISTRICT OFFICE SDV -1 O 10 277 -1 270 990 800 13 64 800 7.5 2 29.6 84.6 Electric Reheat Coil VAV -17 -04 DTUAPBP SDV -06 6 277 -1 90 375 130 15 79 130 1.5 1 36.5 91.5 Bectric Reheat Coil VAV -17 -05 CONFERENCE SDV -08 8 277 -1 140 610 200 11 66 200 2.0 1 31.6 86.6 Bectric Reheat Coil VAV -17 -06 INVESTIGATION SDV -O8 8 277 -1 165 650 250 14 71 250 2.5 1 31.6 86.6 Bectric Reheat Coil VAV -17 -07 OFFICETITS SDV -06 6 277 -1 80 380 255 13 80 255 2.5 1 31.0 86.0 Bectric Reheat Coil VAV -17 -08 3TROOM/LOUNGE/CIRCULAT SDV -12 12 277 -1 420 855 795 15 36 795 7.5 2 29.8 84.8 Bectric Reheat Coil VAV -17 -09 ENCLAVE SDV -06 6 277 -1 80 175 125 13 34 125 1.5 1 37.9 92.9 Bectric Reheat Coil VAV -17 -10 EQUIPMENT RM SDV -06 6 277 -1 80 240 100 13 48 100 1.0 1 31.6 86.6 Bectric Reheat Coil VAV -17 -11 By -Pass SDV -14 14 120 -1 0 2,251 0 72 T -0627 South Center, WA - 11/05/10 3:24 PM & I 0411111, II Sib 0©© 4 / ROOFTOP UNIT MIEFTIPMFFIF HVAC HVAC DEMO NEW I7 T I I I _ -- -r - -' I _ 7 1 1 1 INSTALLATION: - - 1-- - I -- - - � l _ _ - -0 - - -e _ -_ -_� -O _ - - -0 - - -- - - --0 �I ;i - - - --�} NEOPRENE GASKET I 111 WOOD NAILER L----- I ® �i� i i 1 - -- 1 - -- 1:f. '-' - fjr -� ,,,...,_ •ATTACH MOUNTING BRACKET TO CURB BEFORE PLACING UNIT ON CURB. •ATTACH BRACKET TO INSIDE TOP OF CURB AS SHOWN USING FOUR TEK SCREWS. •AFTER PLACING UNIT ON CURB, ATTACH BOTTOM OF BRACKET TO BASE RAIL OF UNIT AS SHOWN WITH FOUR TEK SCREWS. HARDWARE PACKAGE: (FURNISHED BY AES) � , `' I _ i �i�l -1 - - -- p _ TEK SCREW. TYP. 1 ' ' 1 - -'- - - � I I I I I I I ;1r" I - -T - -� i . I - I 1 1 1 -- II 4Nll 11 o ' - BRACKET FURNISHED BY AES INDUSTRIES. e- N ' " SEE DETAIL 4/M601. �_- _- _ -_ -_ -_ II RIGID INSULATION NIC. II AES INDUSTRIES D- II ROOF CURB ROOF MEMBRANE NIC. - - - - - - u \\--... ROOF DECK o--------- - - - - - - _- ____1___D___J___J___I1___ii _ -_11 _ 1 I I I I I 1 I I 1 1 -�- - - - I_- _ -I_ -_ I_ -_ I_ -_ I_ -_ I_ -_ I_ -- - - - - - - - •FOUR (4) 10 GA. STEEL ATTACHMENT •TTHIRTY WO (32) *10 TEK SCREWS. •TWO BRACKETS ON EACH SIDE OF LONG SIDES OF CURB EQUALLY SPACED ,,,P:7;;;;;;,::::::,:•::4';,:,,:::::::::•:::4•;:z•::,:z.:;.:;:::,:',:•::•:::?, ATION � �I; ���� f 4 • I I I I IL,, 1 I 4 -- -_i-4 ligli NOT TO SCALE RTU HOLD -DOWN BRACKET INSTALLATION DETAIL DATE ISSUED ISSUES AND REVISIONS VERSION mum 08 08-06-10 �8 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY D. SCOTT CHECKED BY D. BENNETT ARCHITECTS PROJECT NO. ( 05-NOV-2010 15:53 NOT TO SCALE RECEIVED NOV 19 2010 PERMIT CENTER - - - - - -I- - - -I - -- - -- - - - - --0 0_ 0 e 0 0 0 0 0 KEY PLAN NOT TO SCALE TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION mum 08 08-06-10 �8 TITLE OFFICE AREA HVAC DEMO & NEW WORK PROJECT CODE 270627 CONFIGURATION LL PLANS SHEET M331 T• WALK -IN REFRIGERATION DEMO PLAN V4" = 1' -0" WALK -IN REFRIGERATION ROOF DEMO PLAN V4"= 1' -0" QUALITY ASSURANCE REVIEW REVIEWED BY: DAVE CREVIER REVIEWERS PHONE: (406) 452 -3321 DATE: 10 /29/10 REFRIGERATION DRAWING INDEX RD01 REFRIGERATION DEMOLITION PLAN R111 REFRIGERATION SYSTEM PLAN R141 REFRIGERATION ROOF PLAN R401 MARKET CASES SETTING PLAN R411 MARKET & PARTIAL ROOF PIPING PLANS R421 WALK -IN COOLER & FREEZER PIPING PLAN R501 REFRIGERATION DETAILS R511 REFRIGERATION DETAILS R521 REFRIGERATION DETAILS R601 REFRIGERATION SCHEDULES R611 REMS CONTROL WIRING PLAN & SCHEDULES R621 MARKET & WALK -IN CONTROL WIRING PLANS ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1 1000 NICOLLET MALL 41NNEAPOLIS, MINNESOTA 55403 CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target\_Projects \MR Projects \0627 WA South Center R \CAD \_ActiveCAD \0627rdOl.dgn TARGET MARKET REFRIGERATION ROOF DEMO PLAN 316"= 1' -0" MARKET REFRIGERATION DEMO PLAN 316"= 1'-0" GENERAL NOTES: KEYNOTES: A. ALL REFRIGERATION DEMOLITION TO BE COMPLETED IN ACCORDANCE TO SPEC SECTION 24 0150 (15601) REFRIGERATION EQUIPMENT RECOVERY AND DEMOLITION INSTRUCTIONS RETAIN ALL REFRIGERATED CASE TRIM AND FASCIA TO BE RE -USED. B. C. COORDINATE DISPOSAL /RECOVERY OF UNUSED REFRIGERATION ASSETS WITH TARGET OSR. VERIFY WITH EMC AND THE REMS DRAWINGS FOR THE RE -USE OF ANY REMS PANELS. PANELS THAT ARE NOT BEING RE -USED SHALL BE SENT BACK TO EMC. D. 1 2 4 5 6 7 8 9 10 11 12 13 REMOVE EXISTING CONDENSING UNIT. REMOVE EXISTING REFRIGERATION PIPING LOCATED ON THE ROOF AND DOWN THROUGH THE PIPE BOX. REMOVE EXISTING REFRIGERATION PIPING AND PIPE SUPPORTS. REFER TO SPECIFICATION FOR DEMOLITION AND REPAIR OF ROOF. REPAIR OF ROOF IS RESPONSIBILITY OF THIS CONTRACTOR, UNLESS NOTED OTHERWISE. SEE 4/A140. EXISTING TYLER DOOR CASE AND FAN KIT MAY BE REUSED. VERIFY LOCATION OF REUSED CASES WITH R401. STORE EXISTING CASES, PREPARE FOR RELOCATION. NOT USED REMOVE EXISTING REFRIGERATION PIPING AND PIPE SUPPORTS. REMOVE EXISTING CONDENSATE PIPING. REMOVE EXISTING EVAPORATOR COIL. REMOVE EXISTING REFRIGERATION PIPING, LIQUID LINE SOLENOID AND PIPING SUPPORTS. REMOVE EXISTING REFRIGERATION CONTROLS AT THE WALK -IN COOLER AND FREEZER. REMOVE ALL REMS PANELS AND WIRE LOCATED IN THE MARKET AREA. NOT USED NOT USED ` DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS VERSION MR201008 08 -06-10 n-09-10 BP -3.0 PERMIT SET CONFIGURATION LL DEMOLITION PLAN DRAWN BY TLY CHECKED BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 1VS2010 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2010 City of Tukwila BUILDING fIVICInto STOCK STOCK DEMO ROOF DEMO - -- -- -- -- I I I I — — -I — —1— — - j- - - - -j- - ----I-----a---- ---4— ---------- 1---- T - - - -1— o—--- - - - - -- - RECEIVED NOV 19 2010 PERMIT CENTER -I -- -- I r I I ----- 4---- {---- - - - --0 0 0 0 0 0 MRKT MRKT ROOF DEMO DEMO ` TARGET STORE SOUTH CENTER WA STORE TO627 VERSION MR201008 08 -06-10 TITLE REFRIGERATION 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL DEMOLITION PLAN SHEET RDO1 T -0627 SOUTH CENTER, WA REFRIGERATION SYMBOLS: CB01 CABO-) SYSTEM NUMBER CALLOUT DUAL TEMP SYSTEM NUMBERS CONDENSER /COMPRESSOR UNIT IDENTIFICATION ROOFTOP COMPRESSOR RACK CONDENSER UNIT — A01 -S REFRIGERATION PIPING (SUCTION LINE) — A01 -L REFRIGERATION PIPING (LIQUID LINE) CD 0 10 O CONDENSATE PIPING PIPING UP PIPING DOWN 120V SOLENOID VALVE ELECTRONIC EVAPORATIVE PRESSURE REGULATING VALVE (EEPR) OUTLINE OF CONDENSER /COMPRESSOR UNIT LOCATED ON ROOF. ARROW REPRESENTS DIRECTION OF AIRFLOW THROUGH UNIT. HUB DRAIN NIC FLOOR SINK NIC Alta CASE FAN KIT AND BLANK -OFF PANEL NOTE: NOT ALL SYMBOLS APPEAR ON ALL DRAWINGS. GENERAL NOTES: A. THIS PLAN SHOWS THE REFRIGERATION SYSTEMS FOR THE SALES FLOOR CASES AND THE STOCKROOM WALK -IN COOLERS /FREEZER. B. SEE P351, P401 OR P411 DRAWINGS FOR DRAIN LOCATIONS. C. REFRIGERATION CONTRACTOR SHALL RECEIVE AND INSTALL OWNER FURNISHED WALK -IN COOLERS /FREEZERS. D. REFRIGERATION CONTRACTOR SHALL RECEIVE AND INSTALL OWNER FURNISHED SALES FLOOR MARKET CASES. E. REFRIGERANT R404A IS IN ACCORDANCE WITH ASHRAE STANDARD 34-2001 'DESIGNATION AND SAFETY CLASSIFICATIONS OF REFRIGERANTS.' F. INSTALL HAIL GUARDS FURNISHED WITH CONDENSING UNITS. G. REFRIGERATION CONTRACTOR SHALL RECEIVE AND INSTALL OWNER FURNISHED ROOFTOP COMPRESSOR RACK AND CONDENSER UNITS RTCR -1 & RTCR -2. H. REFRIGERATION CONTRACTOR SHALL RECEIVE AND INSTALL OWNER FURNISHED CONDENSER /COMPRESSOR UNITS. I. SEE REFRIGERATION SCHEDULES ON SHEET R601 FOR SYSTEM CIRCUITS. J. FOR THE OWNER FURNISHED ROOFTOP COMPRESSOR RACK, WALK -IN COOLER /FREEZER CONDENSER /COMPRESSOR UNITS AND EVAPORATOR COILS, THE VENDOR WILL BE EITHER HILL PHOENIX OR HUSSMANN. THE PROTOTYPE DESIGN IS BASED ON HILL PHOENIX EQUIPMENT. REVIEW VENDOR SHOP DRAWINGS AND COORDINATE EQUIPMENT DIMENSIONS AND CONNECTIONS WITH THE GENERAL CONTRACTOR AND OTHER TRADES PRIOR TO INSTALLATION. 1;3 •1 PRODUCE LABELING 184 II II (D 04) (D03) (D02) I MEAT (COOLER 182 PRODUCE COOLER 183 (Co1) FREEZER 181 (D01) GOOLE 180 I_ Owl UP T II I I II WIN dj L ---- L----------------- - - - - -- SALES 102 I I I I I I I � I ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. L_ J 0 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target \Projects \MR Projects \0627 WA South_Center R \CAD \_ActiveCAD \0627r111.dgn //-5--10 TARGET .gills ` 1111111111' 111111111. , • -F —T— - -- REFRIGERATION SYSTEM PLAN 1 40 t" Goo - - -- -- - -- REVIEWED FOR CODE COMPLIANCE A DDOnVED DEC 1 U 2Uhil City of Tukwila BUILDING IJIUISIGN l ', A 4111r A14 A051111 `O; All (B02) (602) I (B03) A021r A 211. MAW A03 (606) (B04) ( BO 7) (B05, I (607) 4(605) 1/16"=V-0" E i] ` DATE ISSUED NOVEMBER 9TH, 2010 (B02) (B02) (602) I (B03) BP -0.0 rid CONFIGURATION LL SYSTEM P LA N 1/16"=V-0" E i] ` DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS VERSION MR2010_08 -06-10 11-09-10 BP -0.0 PERMIT SET CONFIGURATION LL SYSTEM P LA N DRAWN BY TLY CHECKED BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 11/52010 — H---- - - - - -- �G ID�is� RECEIVED NOV 19 2010 PERMIT CENTER SCALE BAR: 16" = 1' -0" IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 0 4' 8' 12' 16' 20' 24' 28' 32' 36' 40' TARGET STORE SOUTH CENTER WAOR STORE T0627 VERSION MR2010_08 -06-10 TITLE REFRIGERATION 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL SYSTEM P LA N SHEET Rill T -0627 SOUTH CENTER, WA -- 1- - - -- --- J------- - - - - -- -H - -- REFRIGERATION ROOF PLAN ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \_Target\_Projects \MR Projects \0627 WA South_Center R \CAD \_ActiveCAD \0627r141.dgn TARGET 146"=V-0" KEYNOTES: 2 3 CONDENSER /COMPRESSOR UNIT AND REFRIGERATION PIPING INSTALLED BY REFRIGERATION CONTRACTOR. RUN REFRIGERATION PIPING FROM CONDENSER /COMPRESSOR UNIT, INTO PIPE BOX AND THROUGH ROOF. SEE R421 FOR CONTINUATION. SEE DETAIL 16/R501. SEE ARCHITECTURAL SHEET A140 FOR PIPE BOX INSTALLATION DETAILS. SET OWNER FURNISHED ROOFTOP COMPRESSOR RACK AND CONDENSER ON ROOF CURBS. SEE ARCHITECTURAL SHEET A140 FOR ROOF CURBS. OWNER FURNISHED REFRIGERATION PIPE BOX. SEE ARCHITECTURAL SHEET A140 FOR INSTALLTION INSTRUCTIONS. I 4 I NOT USED I-5-1 NOT USED 6 INSTALL A 12' PIECE OF INSULATION ON ALL UNINSULATED REFRIGERATION LINES. INSULATION WILL BE USED TO HELP SECURE PIPE LABELS. GENERAL NOTES: A. SEE SPECIFICATIONS FOR SPACING OF PIPE SUPPORTS. SEE ARCHITECTURAL SHEET A140 FOR PIPE SUPPORT DETAIL. B. NEW HVAC EQUIPMENT INSTALLED BY MECHANICAL CONTRACTOR. C. FOR THE OWNER FURNISHED ROOFTOP COMPRESSOR RACK AND WALK -IN COOLER /FREEZER CONDENSER /COMPRESSOR UNITS, THE VENDOR WILL BE EITHER HILL PHOENIX OR HUSSMANN. THE PROTOTYPE DESIGN IS BASED ON HILL PHOENIX EQUIPMENT. REVIEW VENDOR SHOP DRAWINGS AND COORDINATE THE EQUIPMENT DIMENSIONS AND CONNECTIONS WITH THE GENERAL CONTRACTOR AND OTHER TRADES PRIOR TO INSTALLATION OF ROOF CURBS. ` DATE ISSUED ISSUES AND REVISIONS NOVEMBER 9TH, 2010 11-09-10 BP-3.0 PERMIT SET DRAWN BY TLY CHECKED BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 1152010 i _R,EvvE JCODIQ Poi AppDnv eANC E DEC 10 2010 (BUj yo f Tuil DIN G DIVISION /,7„x EQUIPMENT SYMBOL BOX TYPE DIMENSIONS TOTAL QUANTITY W' X L' X D' O18'x18'x24' 5 OB 24'x24'x24' - O24'x72'x24' - O24'x90'x24' 1 O24'x96'x24' O24'x108'x24' 1 O24'x120'x24' - , O24'x138'x24' - !Gro tsR RECEIVED NOV 19 2010 PERMIT CENTER SCATL1E BA�-R�: T A6''1- = 1'-0° i I1-I Tit! 0 4' 8' 12' 16' 20' 24' 28' 32' 36' 40' TARGET STORE S STORE V VERSION T TrFLE 301 STRANDER BLVD 2 PROJECT CODE C CONFIGURATION R ROOF P LA N nameofpersonplotting 1152010 i _R,EvvE JCODIQ Poi AppDnv eANC E DEC 10 2010 (BUj yo f Tuil DIN G DIVISION /,7„x EQUIPMENT SYMBOL BOX TYPE DIMENSIONS TOTAL QUANTITY W' X L' X D' O18'x18'x24' 5 OB 24'x24'x24' - O24'x72'x24' - O24'x90'x24' 1 O24'x96'x24' O24'x108'x24' 1 O24'x120'x24' - , O24'x138'x24' - !Gro tsR RECEIVED NOV 19 2010 PERMIT CENTER SCATL1E BA�-R�: T A6''1- = 1'-0° i I1-I Tit! 0 4' 8' 12' 16' 20' 24' 28' 32' 36' 40' TARGET STORE S STORE V VERSION T TrFLE 301 STRANDER BLVD 2 PROJECT CODE C CONFIGURATION R ROOF P LA N !Gro tsR RECEIVED NOV 19 2010 PERMIT CENTER SCATL1E BA�-R�: T A6''1- = 1'-0° i I1-I Tit! 0 4' 8' 12' 16' 20' 24' 28' 32' 36' 40' TARGET STORE S STORE V VERSION T TrFLE 301 STRANDER BLVD 2 PROJECT CODE C CONFIGURATION R ROOF P LA N SHEET R141 T -0627 SOUTH CENTER. WA ■ (AB01) (B06) 8 -WS0 (B06) Zl -1^190 (B07) Z4-11S0 (B07) I. 104-12 (B02) 8 -11SO (B02) Zl -INSO 11-09-10 (B02) j (B03) Z4 -INSO { Z4 -11S0 CONFIGURATION LL SETTING PLAN 1 / \ 05M -8 05M -12 O1M -12 i (B04) (BO1) (B04) (B05)' . I (B05) JA ARCHFFECTS PROJECT NO. I O U cr, (B02) 8 -11SO (B02) Zl -INSO 11-09-10 (B02) j (B03) Z4 -INSO { Z4 -11S0 CONFIGURATION LL SETTING PLAN DRAWN BY TLY i 1 (BO1) UNDERFLOOR REFRIGERATION PLAN 1/4" = 1' -0" KEYNOTES: GENERAL NOTES: 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 REMS -3 PANEL. SEE DETAIL 4/R511. INSTALL CASE MANUFACTURER FURNISHED TRIM PIECES ON ALL CASES. SEE DETAILS 5/R511 AND 12/R511. INSTALL CASE MANUFACTURER FURNISHED FAN BLOWER KITS. SEE DETAILS 5/R511, 6/R511 AND 12/R511. REMS -4 PANEL. SIMILAR TO DETAIL 4/R511. DUAL TEMPERATURE CASE. CASE COMES FURNISHED WITH ANTI -SWEAT HEATER CONTROL AND RELAYS FOR CONTROL OF THE EVAPORATOR FAN AND DEFROST. INSTALL CASE MANUFACTURER FURNISHED INSULATED PARTITION BETWEEN CASES. INSTALL CASE MANUFACTURER FURNISHED FAN BLOWER KITS. SEE DETAIL 16/R511. SIMILAR TO DETAILS 5/R511 AND 6/R511. INSTALL CASE MANUFACTURER FURNISHED PLEXIGLASS PARTITION BETWEEN CASES. INSTALL CASE MANUFACTURER FURNISHED RUNNING TRAP. DO NOT INSTALL CENTER ADJOINING BOLT BETWEEN THE TWO HILL PHOENIX OPEN MULTI -DECK CASES. EXISTING TYLER FROZEN CASE WITH ELECTRIC DEFROST. CONVERT CASE TO HOT GAS DEFROST BY INSTALLING OWNER FURNISHED TYLER DEFROST CONVERSION KIT AND REMOVE THE EXISTING LIQUID /SUCTION HEAT EXCHANGER. THE DEFROST CONVERSION KIT WILL BE DELIVERED WITH THE NEW OPEN MULTI -DECK CASES. INSTALL DEFROST CONVERSION KIT ACCORDING TO TYLER'S INSTALLATION INSTRUCTIONS. THE TYLER DEFROST CONVERSION KIT INSTALLATION INSTRUCTIONS WILL BE FURNISHED WITH THE CONVERSION KITS AND ARE ALSO INCLUDED WITH THE REFRIGERATION SPECIFICATIONS. REPLACE CASE MOUNTED LIQUID DRIER WHERE APPLICABLE, LIQUID DRIER TO BE OWNER FURNISHED. EXISTING TYLER DAIRY CASE. TO CONVERT THE CASE FOR USE WITH R404A REFRIGERANT, INSTALL OWNER FURNISHED R404A EXPANSION VALVE AND DISTRIBUTOR ORIFICE. THE OWNER FURNISHED PARTS WILL BE DELIVERED WITH THE NEW OPEN MULTI -DECK CASES. REPLACE CASE MOUNTED LIQUID DRIER WHERE APPLICABLE, LIQUID DRIER TO BE OWNER FURNISHED. EXISTING TYLER FROZEN /DUAL -TEMP CASE. REPLACE THE EXISTING RETURN TEMPERATURE SENSOR WITH A NEW OWNER FURNISHED COIL MOUNTED DEFROST TERMINATION SENSOR. OWNER FURNISHED PARTS WILL BE DELIVERED WITH THE NEW OPEN MULTI -DECK CASES. THE NEW CASES WILL COME FURNISHED WITH DEFROST TERMINATION SENSORS. SEE REMS DRAWINGS FROM EMC FOR INSTALLATION DETAILS. INSTALL CASE MANUFACTURER FURNISHED INSULATED CASE ENDS BETWEEN NEW HUSSMANN CASE AND EXISTING TYLER CASE. INSTALL RE -USED TYLER CASE FAN BLOWER KITS. SEE DETAILS 5/R511, 6/R511, 12/R511 AND 16/R511. REFRIGERATION PIPING DOWN IN FALSE COLUMN TO UNDERFLOOR BOX. SIMILAR TO DETAIL 8/R521. DIMENSIONS SHOWN ARE TO SUCTION LINE STUB -UP LOCATION. ADJUST BOX LOCATION AS NEEDED. SEE DETAILS 5/R521, 6/R521 AND 7/R521. 6' PVC ELBOW. NOT USED A. REFRIGERATION CONTRACTOR SHALL RECEIVE, UNLOAD, SET, ALIGN, AND LEVEL CASES INCLUDING THE JOINING OF CASES AND INSTALLATION OF ANY COVER PLATES AND TRIM STRIPS. B. SEE R411 FOR CASE PIPING. C. SHIM HUSSMANN GLASS DOOR CASE TO ALLIGN DONUT GASKET. D. REFRIGERATION UNDERGROUND BOX IS PROVIDED BY REFRIGERATION CONTRACTOR. E. PVC REFRIGERATION SLEEVE FURNISHED AND INSTALLED BY REFRIGERATION CONTRACTOR. F. REFRIGERATION PIPE BOXES ARE NOTED WITH A O SEE UNDERFLOOR BOX SCHEDULE. SEE DETAILS 5/R521, 6/R521 AND 7/R521. G. WHEN RELOCATING EXISTING CASES USE NEW END PANELS AS REQUIRED. NEW END PANELS TO BE OWNER FURNISHED. H. INSTALL CASE MANUFACTURER FURNISHED TRIM PIECES ON ALL CASES. OA UNDERFLOOR BOX SCHEDULE BOX TYPE DIMENSIONS W' X L' X D' TOTAL QUANTITY 185(18'x24' 1 ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. L_ J 0 I 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454A 873 WWW.CTAGROUP.COM Y: \Target \Projects \MR Projects \0627 WA South_Center R \CAD \_ActiveCAD \0627r401.dgn /t-5"--/c2 TARGET I REVIEWED FOR CODE COMPLIANCE APDPAVED DEC 10 2010 City of Tukwila BUILDING DIVIIfN ti In T N, T ti N, io 32' -11' / 14 • 2 5 -9- (A08) D3Sn -3U £ND3Sd (A08 • *111 13 03Sn -38 SNOdSd / (A09) 2 9 PN18 (A09) 2 9 SN18 RL N4 2 9 (A06) 15 RLN4 I 2 9 (A06) ClIMEMINIZEZEIMMINIMMINITSIMINVINIETIcassourassme RL N4 2 9 (AO7) RLN5 2 91 (A07) • 3' -5' iI 32' -11' 32'-11' / I r 2 5 _9- A302 (A04 ) 2 9 ON1a (A04) 2 9 fN18 2 9 ON18 (A05) 2 9 SN1a RL N4 2 9 (A02) RLN4 2 9 RL N4 2 9 (A03) RLN5 91 2 A03 7 3' -6' 32' -11' I / 32' -11' 8 2 5 _9- (AB01) (B06) 2 9 8 -INSO 10 (806) 2 9 2L-WS0 10 (307) 2 9 2L -WS0 10 (Bo7) ZL- 11•U[ :I TIT [ 7MMEMMUMMEON -12 B04 10 05M -8 2 9 (B04) [7011111111111111111111111[:[ 10 05M -12 2 9 IDA MIN 11111111111111M1 IIE MI= MOVIR (B05) 10 0 M -12 9 805 �— — — — — — — — — — — — I— - -- 32' -11.— — — — — — — — — — — — — 2 9 (A01C) m N CIWIZ -8 12 9 2 9 9 -ZIMO 0 m N (A01D) 2 9 3' -10' 32' -8' DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS VERSION mum) 08 11-09-10 BP-3.0 PERMIT SET CONFIGURATION LL SETTING PLAN DRAWN BY TLY CHECKED BY JA ARCHFFECTS PROJECT NO. nameofpersonplotting 1V52010 2 9 (BO1) 0 N B02 2 9 8 -w50 (602) 2 9 21.-INSO (B02) 2 9 21.-PIS0 (B03) 2 Z1.-WSO 10 10 1 MARKET CASE SETTING PLAN 10 m a 0 14 M N 3' -5' \ 2 9 z a (810 ) Z 2 9 x Z U1 (308) I li id tip R401 3/16" = 1' -0" -1)6 ro-- s 3' -5' m A RECEIVED NOV 19 2010 PERMIT CENTER SCALE BAR: %4" = 1' -0" IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 0 1' 2' 3' 4' 5' 6' 7' 8' 9' 10' \ TARGET STORE SOUTH CENTER WA08-06-10 STORE T0627 VERSION mum) 08 TITLE MARKET CASES 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL SETTING PLAN SHEET R401 T -0627 SOUTH CENTER, WA 1 TCR -CU s 1 1 I I 1 I I 1 1 1 1 I 1 1 10 TYP. ii 0 11 8 I- 10 TYP. 2R� i I I 1 I 1 C I ■ I ■ I SO WOO kt I I I I I 1 1 I I I I I 1 1 I I I 8 L }A09 }A07 L}408 L1-406 L }AB03 L]—A05 SD—A03 L }AB05 L —AB04 SD—A01 L }AB01 L}404 L_1—A02 S] —AB02 S AB06 L }SPARE S AB07 L }SPARE • I "..11= . II PARTIAL ROOF PIPING PLAN L} SPARE ' L}SPARE L —B01 —B02 L]—B03 —B04 L]- -B06 L —B05 L —B07 ]—B 10 L: —B09 L]—B08 I I 1`— -•♦ V4" = 1' -0" ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. L- 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \_Target\_Projects \MR Projects \0627 WA South_Center R \CAD \_ActiveCAD \0627r411.dgn TARGET KEYNOTES: 1 2 3 4 5 6 7 8 9 10 11 LIQUID AND SUCTION PIPING UP THROUGH ROOF AND INTO PIPE BOX. SEE 1/R511 AND DRAWING 2/R411 FOR CONTINUATION. PROVIDE DOUBLE SUCTION RISERS FROM CEILING SPACE TO ABOVE ROOF AS NOTED ON REFRIGERATION SCHEDULE WHEN RISERS ARE GREATER THAN 6' IN HEIGHT. INSTALL OWNER FURNISHED ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT ON UNIT SUPPORTS. SEE SHEET R141. ROUTE REFRIGERATION PIPING RACK THROUGH CEILING SPACE. FIELD COORDINATE EXACT PLACEMENT WITH OTHER TRADES TO AVOID CONFLICTS AND INTERFERENCES. SEE DETAILS 11/R511, 8/R511, 2/R511 AND 3/R511. FOR AN ALTERNATIVE DESIGN SEE 3/R521. ROUTE REFRIGERATION PIPES DOWN IN WALL SPACE. CONNECT TO SALES FLOOR CASES. SEE DETAILS 1/R511, 2/R511, 3/R511, 10/R511, 12/R511 AND 4/R511. ROUTE REFRIGERATION PIPES DOWN IN FALSE COLUMN. CONNECT TO SALES FLOOR CASES. SEE ARCHITECTURAL SHEETS A111 AND A501 FOR FALSE COLUMN LOCATIONS AND DETAILS. SEE DETAILS 1/R511, 2/R511 AND 3/R511. SIMILAR TO DETAIL 4/R511. INSTALL A 12' PIECE OF INSULATION ON ALL MED TEMP LIQUID LINES. INSULATION WILL BE USED TO HELP SECURE PIPE LABELS. THE SUCTION RISER FOR EACH DUAL TEMP SYSTEM SHALL BE DOUBLE SUCTION TYPE. SEE DETAIL 9/R511. SEE REFRIGERATION SCHEDULE ON SHEET R601 FOR SIZES. REFRIGERATION PIPING INTO PIPE BOX AND DOWN THROUGH ROOF. SEE 1/R411 FOR CONTINUATION. SEE DETAILS 1/R511, 2/R511 AND 3/R511. SEE R141 FOR PIPE BOX SIZES. REFRIGERATION PIPING INSTALLED ON ROOF. PROVIDE PROTECTIVE JACKET ON INSULATED PIPING PER SPECIFICATION. SEE ARCHITECTURAL SHEET A140 FOR ROOF PIPE SUPPORTS. 4x4 ROOF PIPE SUPPORT, TYPICAL. SEE DETAIL 14/R511 & ARCHITECTURAL SHEET A140. FOR AN ALTERNATE DESIGN SEE 4/R521. FULL TIME DISCHARGE, SEASONAL DISCHARGE, MAIN LIQUID LINE, RECEIVER PRESSURIZATION, HIGH -LOW BYPASS AND PUMP -OUT REFRIGERATION PIPING CONNECTING TO THE ROOFTOP COMPRESSOR RACK AND CONDENSER. THE COMPRESSOR RACK AND CONDENSER COME FURNISHED WITH PIPE STUBS FOR CONNECTION POINTS. VERIFY CONNECTION POINT LOCATIONS WITH EQUIPMENT SHOP DRAWINGS. INSTALL PIPING ON ROOF PIPE SUPPORTS. SEE ARCHITECTURAL DRAWINGS FOR PIPE SUPPORT DETAILS. SEE REFRIGERATION SPECIFICATION FOR PIPE SUPPORT SPACING REQUIREMENTS. SIZE PIPING PER THE REFRIGERATION SCHEDULES ON R601. 12 NOT USED 13 14 15 16 A01 SUCTION AND LIQUID LINES DOWN IN FALSE COLUMN. DOWN BETWEEN CASES AND DOWN TO UNDERFLOOR BOX. SEE 2 /R401 FOR CONTINUATION SEE DETAIL 8 /R521 NOT USED NOT USED NOT USED GENERAL NOTES: A. REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL REFRIGERATION PIPING AND HANGERS FROM ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT TO REFRIGERATED CASE CONNECTIONS. B. NOT USED. C. 1' GALVANIZED CONDENSATE TRAPS ON REFRIGERATED CASES SHALL BE FACTORY INSTALLED. D. THE CASE CONDENSATE LINE SIZE SHALL MATCH THE SIZE OF THE FACTORY INSTALLED CONDENSATE TRAP FOR EACH CASE. CONDENSATE LINES SHALL BE INSTALLED ACCORDING TO LOCAL PLUMBING CODES. E. SEE PLUMBING DRAWINGS FOR MARKET AREA FLOOR DRAIN LOCATIONS. F. SEE HORIZONTAL PIPING HANGER SPACING TABLE IN SPECIFICATION FOR MAXIMUM SPACING OF ROOF PIPE SUPPORTS. SPACING SHALL BE BASED ON THE SMALLEST SIZED PIPE BEING SUPPORTED. G. SEE R401 FOR INSTALLATION OF CASE TRIM, FAN KITS AND REMS PANELS. H. SEE DETAIL 13/R511 FOR PIPING CIRCUITS WITH HOT GAS DEFROST. REVIEWED FOR CODE COMPLIANCE ADDIVIVED DEC 10 and City of Tukwila BUILDING DIVI.fiInN • DATE ISSUED NOVEMBER 9TH, 2010 1 = = = = _ - = n di ro r C I ■ I ■ I SO WOO kt I I I I I 1 1 I I I I I 1 1 I I I 8 L }A09 }A07 L}408 L1-406 L }AB03 L]—A05 SD—A03 L }AB05 L —AB04 SD—A01 L }AB01 L}404 L_1—A02 S] —AB02 S AB06 L }SPARE S AB07 L }SPARE • I "..11= . II PARTIAL ROOF PIPING PLAN L} SPARE ' L}SPARE L —B01 —B02 L]—B03 —B04 L]- -B06 L —B05 L —B07 ]—B 10 L: —B09 L]—B08 I I 1`— -•♦ V4" = 1' -0" ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. L- 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \_Target\_Projects \MR Projects \0627 WA South_Center R \CAD \_ActiveCAD \0627r411.dgn TARGET KEYNOTES: 1 2 3 4 5 6 7 8 9 10 11 LIQUID AND SUCTION PIPING UP THROUGH ROOF AND INTO PIPE BOX. SEE 1/R511 AND DRAWING 2/R411 FOR CONTINUATION. PROVIDE DOUBLE SUCTION RISERS FROM CEILING SPACE TO ABOVE ROOF AS NOTED ON REFRIGERATION SCHEDULE WHEN RISERS ARE GREATER THAN 6' IN HEIGHT. INSTALL OWNER FURNISHED ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT ON UNIT SUPPORTS. SEE SHEET R141. ROUTE REFRIGERATION PIPING RACK THROUGH CEILING SPACE. FIELD COORDINATE EXACT PLACEMENT WITH OTHER TRADES TO AVOID CONFLICTS AND INTERFERENCES. SEE DETAILS 11/R511, 8/R511, 2/R511 AND 3/R511. FOR AN ALTERNATIVE DESIGN SEE 3/R521. ROUTE REFRIGERATION PIPES DOWN IN WALL SPACE. CONNECT TO SALES FLOOR CASES. SEE DETAILS 1/R511, 2/R511, 3/R511, 10/R511, 12/R511 AND 4/R511. ROUTE REFRIGERATION PIPES DOWN IN FALSE COLUMN. CONNECT TO SALES FLOOR CASES. SEE ARCHITECTURAL SHEETS A111 AND A501 FOR FALSE COLUMN LOCATIONS AND DETAILS. SEE DETAILS 1/R511, 2/R511 AND 3/R511. SIMILAR TO DETAIL 4/R511. INSTALL A 12' PIECE OF INSULATION ON ALL MED TEMP LIQUID LINES. INSULATION WILL BE USED TO HELP SECURE PIPE LABELS. THE SUCTION RISER FOR EACH DUAL TEMP SYSTEM SHALL BE DOUBLE SUCTION TYPE. SEE DETAIL 9/R511. SEE REFRIGERATION SCHEDULE ON SHEET R601 FOR SIZES. REFRIGERATION PIPING INTO PIPE BOX AND DOWN THROUGH ROOF. SEE 1/R411 FOR CONTINUATION. SEE DETAILS 1/R511, 2/R511 AND 3/R511. SEE R141 FOR PIPE BOX SIZES. REFRIGERATION PIPING INSTALLED ON ROOF. PROVIDE PROTECTIVE JACKET ON INSULATED PIPING PER SPECIFICATION. SEE ARCHITECTURAL SHEET A140 FOR ROOF PIPE SUPPORTS. 4x4 ROOF PIPE SUPPORT, TYPICAL. SEE DETAIL 14/R511 & ARCHITECTURAL SHEET A140. FOR AN ALTERNATE DESIGN SEE 4/R521. FULL TIME DISCHARGE, SEASONAL DISCHARGE, MAIN LIQUID LINE, RECEIVER PRESSURIZATION, HIGH -LOW BYPASS AND PUMP -OUT REFRIGERATION PIPING CONNECTING TO THE ROOFTOP COMPRESSOR RACK AND CONDENSER. THE COMPRESSOR RACK AND CONDENSER COME FURNISHED WITH PIPE STUBS FOR CONNECTION POINTS. VERIFY CONNECTION POINT LOCATIONS WITH EQUIPMENT SHOP DRAWINGS. INSTALL PIPING ON ROOF PIPE SUPPORTS. SEE ARCHITECTURAL DRAWINGS FOR PIPE SUPPORT DETAILS. SEE REFRIGERATION SPECIFICATION FOR PIPE SUPPORT SPACING REQUIREMENTS. SIZE PIPING PER THE REFRIGERATION SCHEDULES ON R601. 12 NOT USED 13 14 15 16 A01 SUCTION AND LIQUID LINES DOWN IN FALSE COLUMN. DOWN BETWEEN CASES AND DOWN TO UNDERFLOOR BOX. SEE 2 /R401 FOR CONTINUATION SEE DETAIL 8 /R521 NOT USED NOT USED NOT USED GENERAL NOTES: A. REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL REFRIGERATION PIPING AND HANGERS FROM ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT TO REFRIGERATED CASE CONNECTIONS. B. NOT USED. C. 1' GALVANIZED CONDENSATE TRAPS ON REFRIGERATED CASES SHALL BE FACTORY INSTALLED. D. THE CASE CONDENSATE LINE SIZE SHALL MATCH THE SIZE OF THE FACTORY INSTALLED CONDENSATE TRAP FOR EACH CASE. CONDENSATE LINES SHALL BE INSTALLED ACCORDING TO LOCAL PLUMBING CODES. E. SEE PLUMBING DRAWINGS FOR MARKET AREA FLOOR DRAIN LOCATIONS. F. SEE HORIZONTAL PIPING HANGER SPACING TABLE IN SPECIFICATION FOR MAXIMUM SPACING OF ROOF PIPE SUPPORTS. SPACING SHALL BE BASED ON THE SMALLEST SIZED PIPE BEING SUPPORTED. G. SEE R401 FOR INSTALLATION OF CASE TRIM, FAN KITS AND REMS PANELS. H. SEE DETAIL 13/R511 FOR PIPING CIRCUITS WITH HOT GAS DEFROST. REVIEWED FOR CODE COMPLIANCE ADDIVIVED DEC 10 and City of Tukwila BUILDING DIVI.fiInN • DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS 1 11-09-10 BP-3.0 PERMIT SET (E (A01A) -05M 8 Bo7 DRAWN BY TLY � jGO T (B02) 8 -YVSO (A01B) (B03) ZL -YISO L I ) CHECKED BY B10 L B05 S ( ) (B05) ( 1 809 80 I JA ARCHITECTS PROJECT NO. B09 L BOSS B08 L „� nameofpersonplotting 11/62010 \ 5 (AB03) r 0 ( AB02) u. B (A08 ) i I' 03S1-1-32J1 2a - LL - - -� ;- run -i11 3 (A09) SN1a 0 a J RL J 4 J RLN5 ' (A07) 0 th 0- 0 N 3 i I i • / • I ;I ' 0 VI I o I a I ITN-11:1 1 i (A04) N (A05) I7Nla 'I (A05 SN18 J 0 a 0 0 a Cry r--N (AB01) N 0 ,I (B06) 0 AOl -S (BO7) 13 X z CID r z (BO7) Igi I IQ 0 A NI 1 m 8 -ZIMO 0�3M-lL cii4l (E (A01A) -05M 8 Bo7 'WAR T � jGO T (B02) 8 -YVSO (A01B) (B03) ZL -YISO L I ) Or m) B10 L B05 S ( ) (B05) ( 1 809 80 I I B09 L BOSS B08 L „� f 1 J to J -J J J to 0 N m o m N 0 m m N o+ 0 m N m 0 N O m to O m U, 0 N O O O) O m m O ••••••••••••••••• J N J M J I! rt o (ABo ) E(101) 0 LII r a, (B01) 0 A NI 1 m 8 -ZIMO o f m N (A01D) (A01A) (A01C) OWIZ-8 I rn 0m (B02) 8 -YVSO (A01B) I! rt o (ABo ) E(101) 0 LII r a, (B01) to m to m m N (802) ZL -WSO 1 o m N m rn 0m (B02) 8 -YVSO (B02) ZL -WSO (B03) ZL -YISO 1 1 IA 1 I 1 MARKET PIPING PLAN R411 316" = 11 -0" P&tosi Z U) (B08) 0 RECEIVED NOV 19 2010 PERMIT CENTER SCALE BAR: 1/4" = 1' -0" IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 0 1' 2' 3' 4' 5' 6' 7' 8' 9' 10' TARGET STORE SOUTH CENTER W STORE T0627 VERSION Muo,o_a8 TIRE & PARTIAL PIPING P LAN S 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL ROOF SHEET R411 T -0627 SOUTH CENTER, WA 2 10 7 8 21 fOr nnI - 2 10-.. I� r_ J 0 vc 0 0 16 0 ii CD 17 5'-7" 18 13 EVAP COIL 19 15 5' -7' I I PRODUCE ' LABELING (D04) 184 MN 0 14 14 19 DO3 S D03 -L — PRODUCE COOLER (DO3) 183 22 EVAP COIL 7' -11' 7' -11' CD N In (D02) MEAT COOLER 182 19 7' -11' 22 EVAP COIL 12 14 2 10 16 MO CD 15 7 8 9 10 2 10 -� r -� I I r , _ _IJ 11 12 1' -6' 9 0 J 0 4 O U a_ w 4 U a w 19 20 FREEZER 181 (col) 16 - -3 14 I I I I I ti I II I I II I II I I II I II I I _ - i _ -ql I - - R /f III 1 ,. III I i. II III I ! III I / II r i III I / III I r II _I III -_LJ III __L -J U 1/4" = 1' -0" 0 7 8 1 1 1 1 1 1 1 J 0 U 0 4 2'-2' U J 0 U d 4 001 -S D01 -L 19 DAIRY COOLER 180 (D01) 12' -3' • 15 9 16 14 15 --- J--- - - - - -- ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target \Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r421.dgn TARGET DATE ISSUED NOVEMBER 9TH, 2010 DRAWN BY TLY GENERAL NOTES: KEYNOTES: R421 1 I I 3 4 5 6 UPROVIDE 7 8 I ' 10 11 12 13 LIQUID AND SUCTION PIPING DOWN THROUGH WALK -IN COOLER /FREEZER ROOF. SEE DETAILS 7/R501 AND 3/R501. I LIQUID AND SUCTION PIPING UP THROUGH ROOF AND INTO PIPE BOX. SEE DRAWING R141 FOR CONTINUATION. SEE ARCHITECTURAL SHEET A140 FOR PIPE BOX. SEE DETAIL 16/R501. INSTALL OWNER FURNISHED CONDENSER /COMPRESSOR UNIT ON ROOF CURBS. SEE SHEET R141. SEE ARCHITECTURAL SHEET A140 FOR ROOF CURB DETAILS. INSTALL OWNER FURNISHED EVAPORATOR COIL UNIT TIGHT TO CEILING. SEE DETAIL 8/R501. PROVIDE 3/4' COPPER CONDENSATE DRAIN WITH HEAT TAPE AND INSULATION IN FREEZER AND COOLER. INSTALL HEAT TAPE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ROUTE PIPING TIGHT TO WALL AND SLOPE PIPING %2' PER 1' -0' MINIMUM IN THE DIRECTION OF FLOW. DO NOT TRAP DRAIN PIPING IN FREEZER. PROVIDE TRAP FOR FREEZER OR COOLER CONDENSATE DRAIN PIPING PRIOR TO CONNECTION WITH COOLER CONDENSATE DRAIN PIPING. TRAP TO BE LOCATED WITHIN WALK -IN COOLER SPACE. %4' COPPER CONDENSATE DRAIN, ROUTE PIPING TIGHT TO WALLS. SLOPE PIPING I /4' PER 1 -0' MINIMUM IN THE DIRECTION OF FLOW. SEE DETAILS 9/R501 AND 3/R501 FOR CONDENSATE DRAIN PIPING IN WALK -IN COOLER AND FREEZER. I ROUTE 3/4' CONDENSATE DRAIN PIPING DOWN TO CONDENSATE PUMP. DROP PIPING FROM JOIST SPACE TO TOP OF WALK -IN COOLER OR WALK -IN FREEZER. SEE DETAIL 11/R511. ROUTE REFRIGERATION PIPING THROUGH JOIST SPACE. FIELD COORDINATE EXACT PLACEMENT WITH OTHER TRADES TO AVOID CONFLICTS AND INTERFERENCES. SEE DETAILS 16/R501, 8/R511, '11/R511 AND OR 3/R521. INSTALL SOLENOID VALVE ON LIQUID LINE FOR WALK -IN COOLER AND WALK -IN FREEZER. SEE DETAIL 7/R501. INSTALL REFRIGERANT LEAK INDICATOR INSIDE AND OUTSIDE OF WALK -IN COOLER AND WALK -IN FREEZER. MOUNT ABOVE DOOR. SEE DETAIL 1/R501. 14 15 16 17 18 19 20 21 22 INSTALL REFRIGERANT LEAK TRANSDUCER IN WALK -IN COOLER AND WALK -IN FREEZER. SEE DETAIL 1/R501. COORDINATE LOCATION WITH ELECTRICAL AND WALK -IN FIXTURES. DOOR SWITCH AND HORN /STROBE ALARM UNIT. SEE DETAILS 1/R501 AND 2/R501. SEE DETAIL 1/R501 FOR DOOR ADJUSTMENTS. HANG PRODUCE DRY LABELING EVAPORATOR COIL AS PER DETAILS 1O/R521, 11/R521 AND SIMILAR TO DETAIL 7/R501. FIELD INSTALL LABELING ROOM THERMOMETER. SEE DETAIL 2/R521. INSTALL EMC PROVIDED RF MODULE IN CENTER OF WALK -IN. CORDINATE LOCATION WITH OTHER DISCIPLINES. SEE DETAIL 15/R521. WALK -IN WITH UNSUPPORTED ROOF PANELS GREATER THEN 19' WIDE. SEE 15/R501, 12/R521 AND 13/R521 FOR WALK -IN PANNEL ASSEMBLY DETAILS. ROUTE %4' CONDENSATE DRAIN PIPING DOWN TO FLOOR SINK. PROVIDE 2' AIR GAP AT FLOOR SINK. INSTALL OWNER FURNISHED EVAPORATOR COIL UNIT TIGHT TO CEILING. SEE DETAIL 8/R501 AND EVAPORATOR 1. A. DIMENSIONS FOR THE EVAP COILS ARE FROM THE INSIDE WALL OF THE COOLERS /FREEZERS. B. REFRIGERATION CONTRACTOR SHALL ERECT OWNER FURNISHED WALK -IN COOLER /FREEZER PANELS AND ALL ASSOCIATED PARTS IN ACCORD WITH MANUFACTURER'S INSTRUCTIONS. FOLLOW ALL DETAILS ON SHEET R501. C. REFRIGERATION CONTRACTOR SHALL INSTALL OWNER FURNISHED TEMPERATURE SENSORS IN WALK -IN COOLERS AND FREEZERS. SEE DETAIL 7/R501. D. REFRIGERATION CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH WALK -IN COOLER /FREEZER WALLS AND ROOF. SEE DETAILS 3/R501, 4/R501, 5/R501 AND 14/R501. E. EVAPORATOR COILS ARE FURNISHED BY OWNER AND INSTALLED BY REFRIGERATION CONTRACTOR. SEE REFRIGERATION SCHEDULE ON SHEET R601. F. BLOCKING BETWEEN WALK -IN FREEZER AND EXTERIOR WALL SHALL BE PROVIDED BY GENERAL CONTRACTOR, INSTALLED BY REFRIGERATION CONTRACTOR. G. REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL REFRIGERATION PIPING AND HANGERS FROM CONDENSER/ COMPRESSOR UNITS TO WALK -IN COOLER AND FREEZER EVAPORATOR COILS. H. CONTRACTOR TO INSTALL MANUFACTURER PROVIDED HAIL GUARD ON CONDENSER /COMPRESSOR UNITS. I. SEE DETAILS 4/R501 AND 5/R501 FOR SPRINKLER AND ELECTRICAL CONDUIT PENETRATIONS IN WALK -IN COOLER OR FREEZER. ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target \Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r421.dgn TARGET DATE ISSUED NOVEMBER 9TH, 2010 DRAWN BY TLY ISSUES AND REVISIONS VERSION 'vIR2010_08 -10 11-09-10 BP -3.0 PERMIT SET CONFIGURATION LL FREEZER PIPING PLAN CHECKED. BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 116/2010 O CODESEWED FOR COMPLIANCE A pDDnVED DEC i City of Tukwila BUILDING DIVI,SInki P&to- is' FEED NOV 19 2010 PERMIT CENTER SCALE BAR: 74" = 1' -0" IIIIIIIIjIIIIIIIIIIIIIIIIII ►IIIIIIIIIIIII 0 1' 2' 3' 4' 5' 6' 7' 8' 9' 10' \ TARGET STORE SOUTH CENTER WA08-06 STORE T0627 VERSION 'vIR2010_08 -10 TITLE WALK-IN COOLER & 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL FREEZER PIPING PLAN SHEET R421 T -0627 SOUTH CENTER, WA •s� 18/4 YELLOW CABLE TO REMS PANEL 22/4 LIGHT GREY CABLE TO REMS PANEL SEAL END OF CONDUIT WITH CALK CONDUIT BY ELECTRICAL CONTRACTOR i SEAL END OF CONDUIT WITH CALK II -I I . II II II II II II II it II II II II II II II II II II II II II II II II I it II II II REFRIGERANT LEAK TRANSDUCER FURNISHED BY REMS VENDOR. MOUNT VERTICALLY TO THE FLOOR INSIDE WALK -IN COOLER AND FREEZER 12' AFF. SEE R421 FOR MOUNTING LOCATION. W I I L-J e ELECTRIC HEAT PROVIDED IN FREEZER DOOR JAMBS. - N I- COOLER / FREEZER DOOR L�J MOUNT REFRIGERANT LEAK INDICATOR PANEL ON INSIDE AND OUTSIDE OF WALK -IN COOLER AND FREEZER. MOUNT ABOVE DOOR. LEAK INDICATORS FURNISHED BY REMS VENDOR. MOUNT ON THE INSIDE & OUTSIDE OF THE FREEZED /COOLER ABOVE THE DOOR (MINIMUM 8' -6' AFF) TYP. SEE R421. VERIFY THAT REFRIG. LEAK INDICATOR ALARM FLASHES & BUZZES WHEN REFRIG. IS PRESENT. VERIFY HEATED VENTS OPERATE PROPERLY AT FREEZER AND MEAT COOLER. INSTALL DOOR OPEN ALARM. MOUNT MAGENTIC DOOR SWITCH. YELLOW LIGHT SHALL BLINK CONSTANTLY WHEN DOOR IS OPEN. YELLOW LIGHT SHALL BE OFF WHEN THE DOOR IS SHUT. INSTALL & ADJUST CLOSER MECHANISM VERIFY TEMPERATURE READING AND ADJUST THERMOMETER TO CORRECT READING. - ADJUST LATCH AND STRIKE MECHANISM SO THAT DOOR WILL LATCH CLOSED. COOLER AND FREEZER DOOR DETAIL ADJUST DOOR CLOSING MECHANISM OR HINGES TO PULL /PUSH DOOR CLOSE FROM OPEN POSITION. ADJUST AND SHIM HINGE PLATES SO THAT DOOR GASKET CONTACTS DOOR FRAME WHEN DOOR IS CLOSED. VERIFY OPERATION OF DOOR FRAME HEATERS ADJUST DOOR SWEEP TO MAKE CONTACT WITH FLOOR SLAB. ELECTRIC HEAT PROVIDED IN BOTTOM OF FREEZER DOOR. SEAL INSULATION TO INSULATED PANEL AND PIPING WITH SILICONE CAULK REFER TO SECTION 07 9200 NOT TO SCALE 3/8' FLEXIBLE ELASTOMERIC INSULATION, IN ACCORD WITH SPECIFICATION 24 0719, GLUED TO CONDUIT (TYPICAL). NOTE: 1. DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS. COOLER /FREEZER CONDUIT PENETRATION UNION (TYPICAL) \ \ \ COOLER EVAP. COIL \I� TRAP COOLER DRAIN PRIOR TO CONNECTION WITH FREEZER CONDENSATE DRAIN. SLOPE CONDENSATE DRAIN IN COOLER I/4' PER FOOT. CO CO NOT TO SCALE ■ l \ ■ \ \ \ \ \ l \ \ \ \ \ \ \ FREEZER EVAP. COIL TRAP LOCATED IN- COOLER PRIOR TO CONNECTION WITH COOLER CONDENSATE DRAIN. PENETRATION THROUGH COOLER WALL INSULATE CONDENSATE DRAIN PIPE OUTSIDE OF THE WALK -IN COOLER OR FREEZER. EXCEPTION - CONDENSATE LINES IN LABELING ROOM DO NOT NEED TO BE INSULATED. SEE SPEC. SECTION 24 0719. TRAP 2' AIR GAP HUB DRAIN CO SLOPE CONDENSATE DRAIN IN FREEZER 1/2' PER FOOT. > COPPER CONSENSATE DRAIN PIPE IN FREEZER AND MEAT COOLER WRAPPED WITH HEAT TAPE AND INSULATION. INSTALL HEAT TAPE IN ACCORD WITH MANUFACTURER'S COMMENDATIONS. CONDENSATE DRAIN PIPING INSTALLATION CONTINUOUS BEAD OF SILICONE CALK REFER SECTION 07 9200 13A6 ' FILLER CENTER AND ADJUST CEILING PANEL TO MAINTAIN A GAP NO GREATER THAN 5A6' AT PERIMETER. FILL VOID SPACE COMPLETELY - WITH FOAM IF GAP EXCEEDS I/4'. TRIM OFF EXCESS FOAM THAT SQUEEZES OUT THE TOP. REFER TO SPEC. SECTION 24 3623. CONTINUOUS WALL PANEL PANEL GASKET 1 /2' DIA. CONTINUOUS BEAD OF BUTYL CALK EXTERIOR NOT TO SCALE 3/8' LAG BOLTS AND WASHERS C 24' O.C. CEILING PANEL IS FURNISHED WITH PRE - DRILLED HOLES. i 1 4 I 1 P . IIM■ $ 01 pl r ■ WALL PANEL CEILING PANEL CEILING TO WALL PANEL JOINT CONTINUOUS BEAD OF SEALANT SLNT -4 AT CEILING TO WALL JOINT. SEE SPECIFICATION SECTION 07 9200. PANEL GASKET INTERIOR NOT TO SCALE 22/4 LIGHT GREY CONTROL CABLE TO WALK -IN REMS PANEL. SEAL END OF CONDUIT WITH CALK CONDUIT UP TO TOP OF WALK -IN ■ WALK -INS COOLER COOLER DOOR ---------"1 NOTES: 1. LOW VOLTAGE WIRING CONNECTIONS BY REFRIGERATION CONTRACTOR. 2. HORN /STROBE DOOR SWITCH UNIT, LOW VOLTAGE CABLE AND CONDUIT INSTALLED BY ELECTRICAL CONTRACTOR. 3. FOR FREEZER, DOOR SWITCH WILL CLOSE LIQUID LINE SOLENOID AND SHUT OFF THE EVAPORATOR FAN WHEN DOOR IS OPEN. 4. SEAL ALL COOLER /FREEZER PANEL PENETRATIONS. SEE DETAIL 3/R501. 18/2 YELLOW CONTROL CABLE TO WALK -IN REMS PANEL. HORN /STROBE DOOR SWITCH UNIT FURNISHED BY REMS VENDOR. 22/4 LIGHT GREY CONTROL CABLE TO PANEL REMS2 ON TOP OF WALK -IN. CONDUIT UP TO- TOP OF WALK -IN FREEZER DOOR 18/2 YELLOW CONTROL CABLE TO WALK -IN REMS PANEL. SEAL END OF CONDUIT WITH CALK HORN /STROBE DOOR SWITCH UNIT FURNISHED BY REMS VENDOR. WALK -IN FREEZER WALK -IN FREEZER AND COOLER DOOR SWITCH/ALARM DETAIL • • TOP OF WALK -IN FREEZER EVAPORATOR COIL DEFROST - TERMINATION SENSOR INSTALLED ON COIL BY EVAPORATOR COIL MANUFACTURER. THE SENSOR WIRE IS COILED UP IN THE ELECTRICAL BOX. NOTES: 1. THE DEFROST TERMINATION SENSOR IS INSTALLED ON WALK -IN FREEZER EVAPORATOR COILS. 2. LOW VOLTAGE CABLE INSTALLED BY ELECTRICAL CONTRACTOR. 3. LOW VOLTAGE WIRING CONNECTIONS BY REFRIGERATION CONTRACTOR. 4. SEAL ALL COOLER /FREEZER PENETRATIONS. SEE DETAIL 3/R501. EXTERIOR EVAP. COIL NOT TO SCALE LIGHT GREY 22/4 CONTROL CABLE TO REMS PANEL. PENETRATION SIMILAR TO DETAIL 14/R501. TEMPERATURE SENSOR PROBE CONNECT CONTROL CABLE TO THE DEFROST TERMINATION SENSOR WIRE COILED IN THE EVAPORATOR COIL ELECTRICAL BOX. WALK -IN EVAPORATOR COIL ELECTRIC DEFROST TERMINATION SENSOR DETAIL I /4' X 11/2' DRIVE PINS C 36' O.C. MAX. STRIP SCREED V2' DIA. CONTINUOUS BEAD OF BUTYL CALK BASE SCREED SLNT -4 FINISHED FLOOR NOT TO SCALE INSULATED PANEL III INTERIOR SEISMIC CLIP AS REQUIRED PER MANUFACTURER INSTALLATION DRAWINGS SLNT -4 6 D ° ° D ° P. • A ° • u ° Ii II V I ' DIA. A ° A III ° ° CO ° v i i i A D ' DBEAD OF NTINUOUS A a I , I ° BUTYL CALK III . t.1 FLOOR TO WALL PANEL JOINT @ WALK -IN COOLER D • D ° I °I .t J V ° FLOOR TILE NIC LOW VOLTAGE CABLE.---A SEAL PENETRATIONS WITH SILICONE CALK REFER TO SECTION 07 9200 546' OD HOPE TUBING. SEAL PENETRATIONS WITH SILICONE CALK REFER TO SECTION 07 9200 NOTE: 1. DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS. NOT TO SCALE LOW VOLTAGE SINGLE WIRE COOLER/FREEZER PENETRATION NOT TO SCALE ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target \Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r501.dgn If (D' TARGET INTERIOR SLNT -4 INSULATED PANEL „""""" "` • EXTERIOR SLNT -4 • INSULATED PANEL NOTE: 1. DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS. PIPE INSULATION TO BE CONTINUOUS THROUGH PENETRATION CUT HOLES I /8' LARGER THAN O.D. OF INSULATED PIPE PANEL PIPE PENETRATION (LIQUID, SUCTION AND DRAIN LINES) NOT TO SCALE MIN 6' HORIZONTAL RUN BEFORE TRAP. INTALL TXV BULB AT 5 O'CLOCK ON A HORIZONTAL RUN AWAY FROM JOINTS. SEAL PENETRATIONS. SEE DETAIL 3/R501. 15/8' UNISTRUT WITH KLO -SHURE CLAMP. EXTERIOR SUCTION PIPING PLAN VIEW 120V AC IN CONDUIT FROM REMS PANEL. SEE ELECTRICAL DRAWINGS. COOLER /FREEZER ROOF EVAP COIL LIQUID PIPING LIQUID LINE SOLENOID VALVES SUPPLIED WITH THE CONDENSER/ COMPRESSOR UNITS. INSTALL ON TOP OF THE WALK -INS. JUNCTION BOX PROVIDED BY EMC. SEAL PENETRATIONS. SEE DETAIL 3/R501. REFER TO REFRIGERATION SCHEDULE FOR PIPE SIZE. 1%' UNISTRUT WITH KLO -SHURE CLAMP. TEMP SENSOR PROBE, SEAL PENETRATION. HAND VALVE LIQUID DRIER, INSULATE DRIER AFTER INSTALLATION INVERTED P -TRAP AT TOP OF RISER. =140 JUNCTION BOX, SEE 5/R501. SEAL PENETRATIONS. SEE DETAIL 3/R501. REFER TO REFRIGERATION SCHEDULE FOR PIPE SIZE. 15/8' UNISTRUT WITH KLO -SHURE CLAMP. TEMP SENSOR, SEAL PENETRATION. COOLER /FREEZER ROOF EVAP COIL P -TRAP AT BOTTOM OF SUCTION RISER. SUCTION PIPING EVAPORATOR COIL PIPING DETAIL /TEMP SENSOR LOCATION NOT TO SCALE FACTORY INSTALLED - PLYWOOD TONGUE INSULATED PANEL 1/2' DIA. CONTINUOUS BEAD OF BUTYL CAULK SLNT -4 FINISHED FLOOR INTERIOR SLNT -4 NOTE: REFER TO DETAIL ON SHEET F111 FOR SPRINKLER INSTALLATION 3/8. FLEXIBLE ELASTOMERIC INSULATION, IN ACCORD WITH SPECIFICATION 24 0719, GLUED TO PIPING (TYPICAL). (V Li 0 2 V A BOOT FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. SEAL INSULATION TO INSULATED PANEL AND PIPING WITH SILICONE CAULK REFER TO SECTION 07 9200 CD 11 YY INSULATED CEILING PANEL NOTE: 1. DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS. 2. SPRINKLER PIPE AND FITTINGS SUPPLIED BY SPRINKLER CONTRACTORS. 3. DO NOT INSTALL INSULATION UNTIL BOOT IS INSTALLED. 4. REFER TO F111 FOR INSTALLATION DETAILS FOR THE SPRINKLER. FIRE SPRINKLER INSULATION AT WALK -IN COOLERS AND FREEZERS PIMA OMEOI \ _ y WAL K -IN ROOF iu SEAL PENETRATIONS WITH SILICONE CALK REFER TO SECTION 07 9200 • • NOTE: DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS. ritvitvvtD FOR ODE COMPLIANCE I OQnVED EXTERIOR qty of Tukwila 4[JILDING DIVISION INSULATED FLOOR PANEL WITH 1/2' PLYWOOD RAISED FLOOR TO WALL PANEL JOINT @ FOOD SERVICE WALK -IN COOLER/FREEZER 3/8' ALL THREAD ROD 1' X 4 -1/2' 12 GA. GALV. PLATE WASHER AT UNDERSIDE OF HANGERS VINYL GASKET %2' DIA. CONTINUOUS BEAD OF BUTYL CAULK ■III ■� .HM MEM EXTERIOR OR COOLER VINYL GASKET NOT TO SCALE FASTEN TO OVER -HEAD STRUCTURE. SEE DETAIL 12/R521 AND 13/R521. 3/8' NUT & WASHER ABOVE AND (2)3/8' NUTS & WASHER BELOW HANGER BRACKET GALV. STEEL TOP HANGER BRACKET SPACING PER DETAIL 12/R521. (PROVIDE BY KYSOR) 8d COATED NAILS, TYP. OF 4 %2' DIA. CONTINUOUS BEAD OF BUTYL CAULK INTERIOR OR FREEZER INSULATED PANEL TYPICAL PANEL TO PANEL JOINT . DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS , 11-09-10 BP-3.0 PERMIT SET CONFIGURATION LL DETAILS DRAWN BY TLY CHECKED BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 1132010 NOT TO SCALE EVAPORATOR COIL SUPPORT pia NOT TO SCALE 15/8' UNISTRUT 38 NUTS & %' WASHERS (TYP) 3/4' FIRE TREATED WOOD BLOCK FIRE TREATED 4x4 TO SPAN MIN 2 ROOF PANEL JOINTS 3/8' FLEXIBLE ELASTOMERIC INSULATION, TYPE 'D' AS PER SPECIFICATION 24 0719 GLUED TO HANGER ASSEMBLY (TYPICAL) (2)3/8' NUT %' WASHER -)/8' ALL THREAD FACTORY BRACKET (TYP) STRIP SCREED #8d COATED NAILS 36' O.C. MAX. 1/2' DIA. CONTINUOUS BEAD OF BUTYL CALK SLNT -4 FINISHED FLOOR NOT TO SCALE INSULATED PANEL ■11e4vm INTERIOR SEISMIC CLIP AS REQUIRED PER MANUFACTURER INSTALLATION DRAWINGS SLNT -4 • A . , A • A a 4 • 4 4 • . c 4 4 4 • 4 • 4 4 4 4 A • • D D D D o . D D D 0 • D D ASA • A D , TRIM VAPOR BARRIER FLUSH WITH FLOOR BEFORE INSTALLING WALK -IN PANELS. D D D • A D 4 D • D • A A • D D D D • A A I I • L • I I • D bl A I ID D I I• • A o _[ J. - .V 1/2' DIA. CONTINUOUS D BEAD OF BUTYL CAULK D . D D ° • D o , p REFER TO ARCHITECTURAL SHEET A352 FOR BLOCKING, ♦♦♦♦♦.♦♦♦♦♦♦♦♦♦.' VAPOR BARRIER AND INSULATION DETAILS D 12 FLOOR° TO WALL PANEL JOINT @ WALK -IN FREEZER ' D D • D D D D CONDENSER/ COMPRESSOR UNIT FACTORY INSTALLED DRIER FACTORY INSTALLED LIQUID LINE SIGHT GLASS INSTALL INTERMEDIATE P -TRAP ABOVE CEILING IF RISER IS ABOVE 15' -0" HIGH NOT TO SCALE PROVIDE PROTECTIVE JACKETING OVER INSULATION FOR EXTERIOR PIPING IN ACCORD WITH SPECIFICATIONS. INVERTED TRAP REQUIRED AT TOP OF SUCTION RISER PIPE BOX .1 INSULATE LIQUID LINES IN ACCORD WITH SPECIFICATIONS. P -TRAP REQUIRED AT BASE OF SUCTION LINE RISERS OVER 6' IN LENGTH. ROOF I - INSULATE SUCTION LINES PER SPECIFICATIONS. ADD INSULATION ON NON- INSULATED LIQUID LINES FROM A POINT 6' OUTSIDE OF THE BOX AND TO A POINT 6' BELOW THE ROOF DECK. USE 3/8' WALL THICKNESS LIQUID LINE SOLENOID ON TOP OF WALK -IN RECEIVED Nov 19 2010 PERMIT CENTER WALK -IN COOLER/FREEZER COND/COMPRESSOR UNIT PIPING 1,&(o'. 151 NOT TO SCALE TARGET STORE SOUTH CENTER WA08 STORE T0627 VERSION MR201008 --06-10 TITLE REFRIGERATION 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL DETAILS SHEET R501 T -0627 SOUTH CENTER. WA PIPING FROM ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT PROVIDE JACKET TO PROTECT EXPOSED INSULATED PIPING ON ROOF IN ACCORD WITH SPECIFICATIONS �- INVERTED TRAP REQUIRED ►r AT TOP OF SUCTION RISER -' - • PIPE BOX SEAL PENETRATIONS AT PIPE BOX AND ROOF DECK. INSULATE REFRIGERATION LINES IN ACCORD WITH SPECS. ADD INSULATION ON NON- INSULATED LIQUID LINES FROM A POINT 6' OUTSIDE OF THE BOX AND TO A POINT 6' BELOW THE ROOF DECK. USE 3/8' WALL THICKNESS PROVIDE DOUBLE SUCTION RISERS FROM CEILING SPACE TO ABOVE ROOF AS NOTED ON REFRIGERATION SCHEDULE WHEN RISERS ARE GREATER THAN 6' IN HEIGHT. ROOF REFRIGERATION PIPING IN < . CEILING WALL OR FALSE COLUMN. P -TRAP REQUIRED AT BASE OF SUCTION LINE. REFRIGERATION PIPING RISER INSTALL INTERMEDIATE SUCTION LINE P -TRAP ABOVE CEILING IF RISER IS ABOVE 15' -0" HIGH PROVIDE DOUBLE SUCTION RISER WHERE NOTED ON PLANS, SEE DETAIL 9/R511 SUCTION AND LIQUID LINE ON TOP OF CASE _- SUCTION AND LIQUID LINE CONNECTION AT TOP OF CASE PIPING SHALL BE INSTALLED BELOW TOP OF TRIM PIECE HIDDEN FROM VIEW. CONTRACTOR TO INSTALL -� CASE MANUFACTURER PROVIDED TRIM PIECE. NOT TO SCALE ELECTRONIC EVAPORATOR PRESSURE REGULATOR (EEPR). INSTALL ON CASES WHERE INDICATED ON THE -N- REFRIGERATION SCHEDULES. SEE R601. INSULATED SUCTION LINE CONNECT TO CASE MANUFACTURER SUPPLIED PIPING. CONTRACTOR TO INSTALL CASE MANUFACTURER FURNISHED FAN BLOWER KITS AND BLANK-OFF PANELS. INSTALL IN ACCORD WITH CASE MANUFACTURER'S INSTRUCTIONS. FASTEN AND SEAL TO CASE AND WALL. SUCTION AND LIQUID PIPING INSIDE CASE BY CASE MANUFACTURER. SET SUCTION AND LIQUID HEADER ON TOP OF 1" THICK BY 4" WIDE STRIP OF RIGID INSULATION SPACED EVERY 4' -0" 3' SPACE BETWEEN WALL AND CASE INTEGRAL TO CASE STRUCTURE. GYP WALL TOP OF SALES FLOOR CASES .7 PROVIDE DOUBLE SUCTION RISERS FROM CEILING SPACE TO ABOVE ROOF AS NOTED 0� REFRIGERATION SCHEDULE WHEN RISERS ARE GREATER 'I THAN 6' IN HEIGHT. SUCTION LINE TO ROOFTOP COMPRESSOR RACK AND c,„..-- CONDENSER UNIT. /I I� SS NOT TO SCALE INVERTED TRAPS DUAL TEMP DOUBLE SUCTION RISER IN FALSE COLUMN OR WALL. LARGER DIAMETER SUCTION RISER. FOR SIZE SEE ICE CREAM SUCTION RISER LINE SIZE COLUMN IN THE ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT AND MARKET AREA REFRIGERATION SCHEDULE ON SHEET R601. CEILING SMALLER DIAMETER SUCTION RISER. FOR SIZE SEE DAIRY SUCTION RISER LINE SIZE COLUMN IN THE ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT AND MARKET AREA REFRIGERATION SCHEDULE ON SHEET R601. SUCTION LINE FROM TOP OF DUAL TEMP CASE. \I TRAP DUAL TEMP DOUBLE SUCTION RISER DETAIL S SUCTION LINE RETURN FROZEN CASE SYSTEM LINE -UP WITH HOT GAS DEFROST LIQUID LINE TAKE OFF CONNECT MAIN LIQUID AND SUCTION LINES FOR SYSTEM LINE -UP TO LIQUID AND SUCTION CONNECTION POINTS FURNISHED AT THE TOP OF THE CASE. ONLY ONE CASE IN THE SYSTEM LINE -UP WILL BE FURNISHED WITH TOP CONNECTIONS. NOT TO SCALE NOTE :1) WHEN RE -USING AND CONVERTING ELECTRIC DEFROST CASES TO GAS DEFROST, ABANDON EXISTING PER CASE PRE- PIPING, RE -PIPE LINEUPS IN ACCORD WITH THIS DETAIL. EVAPORATOR E J VERSION MR2010_08 -06-10 EVAPORATOR i iil,' TXV J CONFIGURATION LL J I DRAWN BY TLY L. L I S L IS / / / / L - - PROVIDE LIQUID AND SUCTION HEADER INSIDE LOWER FRONT PART OF CASE AND CONNECT TO EVAPORATOR COILS. INSTALL ACCORDING TO CASE MANUFACTURER'S INSTALLATION INSTRUCTIONS. II II /I /1 I 'I '1 ,/ ,/ I ,I I / I / 1 • I • I I ' 1 .' - I L- L - -- L -- PIPING DETAIL FOR FROZEN CASE LINEUP WITH HOT GAS DEFROST PIPING FROM ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT PROVIDE JACKET TO PROTECT EXPOSED INSULATED PIPING ON ROOF IN ACCORD WITH SPECIFICATIONS PIPE BOX, COORDINATE WITH ARCHITECTURAL DRAWINGS INVERTED P -TRAP AT TOP OF SUCTION RISERS REFRIGERANT PIPING SEAL PENETRATIONS AT PIPE BOX AND ROOF DECK. HANGER SEE DETAIL 8/R511 OR 3/R521 INVERTED P -TRAP AT TOP OF SUCTION RISER ROOF ■ 11 I I WA .■■■■■■ SEAL PENETRATIONS AT PIPE BOX TRAP AT BOTTOM OF SUCTION RISERS IMO 1' -0' REFRIGERATION PIPING RISERS CEILING CEILING SLOPE REFRIGERATION PIPING 1' IN 20' TOWARD ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT. REFRIGERANT PIPING TO BE INSTALLED IN FALSE COLUMN. SEE ARCHITECTURAL DETAIL 4/A501 FOR ENCLOSURE. It 7' CASES FOR CONTINUATION SEE DETAIL 16/R511 ■ \_ TRAP AT BOTTOM OF SUCTION RISER III I CONTRACTOR TO INSTALL CASE MANUFACTURER PROVIDED TRIM PIECE. FINISHED FLOOR J L_ REFRIGERANT PIPING FOR SALES FLOOR CASES @ FALSE COLUMN NOT TO SCALE CONTRACTOR TO INSTALL CASE MANUFACTURER PROVIDED TRIM PIECE. FAN BLOWER KIT TO VENTILATE SPACE BETWEEN BACK OF CASE AND WALL. REFRIGERATION PIPING / INSTALL CASE MANUFACTURER K/ FURNISHED END TRIM PLATE ON BOTH ENDS OF LINEUP. 1 4'SPACE BETWEEN WALL AND CASE INTEGRAL TO CASE STRUCTURE. GYP WALL INSTALL CASE MANUFACTURER FURNISHED END KICK PLATE EXTENSION. 17,,„.---- FINISHED FLOOR CASE FAN BLOWER DETAIL - CASE TO WALL RISER SUPPORT DETAIL STRUT MOUNTED NOT TO SCALE CLAMP REFRIGERATION PIPING INSULATION COUPLING OR INSULATED INSERT. REFER TO SPEC. SECTION 24 0719. UNISTRUT MOUNTED TO ARCHITECTURAL STEEL STUD. INVERTED P -TRAP AT TOP OF RISER SUCTION LINE REFRIGERATION PIPE WITH INSULATION AND PVC JACKET LIQUID AND SUCTION PIPING FROM TOP OF CASE TO INSIDE LOWER FRONT OF CASE FURNISHED BY CASE MANUFACTURER. 1- SUCTION LINE MAY BE REDUCED / / / NOT TO SCALE ONE PIPE SIZE AFTER Ys OF LOAD AND REDUCED AGAIN ONE PIPE SIZE AFTER % OF THE LOAD. THE SUCTION HEADER SHOULD NOT BE REDUCED BELOW THE COIL CONNECTION SIZE. INCREASE LIQUID LINE TWO SIZES OVER LINE SIZE FOR IN CASE LIQUID HEADER. TAKE OFFS TO EVAPORATORS EXIT BOTTOM OF LIQUID LINE. PROVIDE 3" EXPANSION LOOP AT CONNECTION TO LIQUID HEADER. UNISTRUT SUPPORT HEIGHT REQUIRED TO 18' MAX TOP OF RISER DETAIL LIQUID LINE NOT TO SCALE %' FLEXIBLE ELASTOMERIC INSULATION, IN ACCORD WITH SPECIFICATION 24 0719, GLUED TO METAL STUD (TYPICAL) APPROVED PIPE HANGER, SEE DETAIL 8/R511 OR 3/R521 NOT TO SCALE MATCH R 4' x 4' TREATED WOOD MIM. 2' LONG WITH WRAPED WITH MEMBRANE SEE ARCH DETAIL 9/A140 FOR DETAILS ON THE WOOD IS WRAPED WITH MEMBRANE AND CONECTED TO THE ROOF. ROOF PIPE SUPPORT DETAIL %" THICK FLAT INSULATION 2 "x6" STUD UNISTRUT SUPPORT BOLT UNISTRUT TO BASE. I / 1 / I / I / i I1 / PIPING FROM ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT PROVIDE JACKET TO PROTECT EXPOSED INSULATED PIPING ON ROOF IN ACCORD WITH SPECIFICATIONS PIPE BOX, COORDINATE WITH ARCHITECTURAL DRAWINGS INVERTED P -TRAP AT TOP OF SUCTION RISERS REFRIGERANT PIPING EXTERIOR SEAL PENETRATIONS AT WALL PIPE BOX AND ROOF DECK. HANGER SEE DETAIL ROOF 8/R511 OR 3/R521 SEAL PENETRATIONS AT PIPE BOX -■ ■ TRAP AT BOTTOM OF SUCTION RISERS REFRIGERATION PIPING RISERS CEILING; SLOPE REFRIGERATION PIPING 1' IN 20' TOWARD ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT. f FINISHED FLOOR REFRIGERANT PIPING TO BE - INSTALLED IN FALSE COLUMN AGAINST OUTSIDE WALL SEE ARCHITECTURAL DETAIL 7/A501 FOR ENCLOSURE. FOR CONTINUATION SEE DETAIL 12/R511 k 7' CASES INVERTED P -TRAP AT TOP OF SUCTION RISER TRAP AT BOTTOM OF SUCTION RISER CONTRACTOR TO INSTALL CASE MANUFACTURER PROVIDED TRIM PIECE. 4' SPACE BETWEEN WALL AND CASE INTEGRAL TO CASE STRUCTURE. 3 REFRIGERANT PIPING FOR SALES FLOOR CASES @ WALL NOT TO SCALE REVIEWED FOR CODE COMPLIANCE APDMIED DEC 1 u 2U10 City of Tukwila BUILDING DIVISION NOT USED CONNECT TO LIQUID AND SUCTION PIPING CONNECTIONS AT THE TOP OF THE CASE. TYPICAL. SUCTION AND LIQUID HEADER PIPING ON TOP OF CASE. - -, / / / I - -7 ' 1 I / 1 I � I, I/ II NOT TO SCALE SET SUCTION AND LIQUID PIPING ON TOP OF 1" THICK BY 4" WIDE STRIP OF RIGID INSULATION SPACED EVERY 4' -0" ON TOP OF CASE. TYPICAL. INSTALL CASE MANUFACTURER FURNISHED TRIM PIECE ON TOP OF CASE. / - -� - 1 - --1 V► / . 1 / / I 1 / M 1/ i 1/ II I - --'1 --I ..- I �'' 1 I / I . I / I / / / I , I / I, I, 1/ 1/ 4 ft- S L SEE DETAIL 5/R511. NOTE: O AVERAGE PIPE SIZE = 1' O AVERAGE PIPE WEIGHT = 1 PLF O MAX NO. OF PIPES PER SUPPORT = 20 O MAX SUPPORT SPACING = 10' -0' O TOTAL MAX WEIGHT = 100 LBS PER SUPPORT O BRACING NOT REQUIRED FOR PIPING 3' AND SMALLER. NOTE: 1) SEE 4/R521 FOR ALTERNATE DETAIL NOT TO SCALE ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. O L_ 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.873 WWW.CTAGROUP.COM- Y: \Target \Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r511.dgn TARGET INSTALL CASE MANUFACTURER FURNISHED 30' LONG BLANK -OFF PANEL. FASTEN AND SEAL TO CASE AND WALL. NOTCH BLANK -OFF PANEL AS NEEDED TO ACCOMMODATE PIPING OR WIRING CONNECTIONS. TYPICAL. INSTALL CASE MANUFACTURER FURNISHED FAN BLOWER KIT. INSTALL IN ACCORD WITH CASE MANUFACTURER'S INSTRUCTIONS. FASTEN AND SEAL FAN KIT TO CASE AND WALL. TYPICAL. CASE PIPING DETAIL REFRIGERATION PIPING DOWN IN FALSE COLUMN TO TOP OF CASE. NOTE: FOR FROZEN SYSTEM CASE LINE -UPS WITH TWO OR MORE CASES AND HOT GAS DEFROST, THE LIQUID AND SUCTION HEADER PIPES ARE INSTALLED INSIDE THE CASES INSTEAD OF ON TOP. SEE DETAIL 13/R511. NOT TO SCALE NOT USED DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS VERSION MR2010_08 -06-10 11-09-10 BP -3.O PERMIT SET CONFIGURATION LL DETAILS DRAWN BY TLY CHECKED BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 1V&2010 NOT TO SCALE INSTALL CASE MANUFACTURER FURNISHED TRIM PIECE ON TOP OF CASE. ■ r 7' TRIM PIECE FRONT REFRIGERATION PIPING 1' PARTITION— BETWEEN CASES ATTACHED TO BOTTOM CHORD JOIST JOIST CASE CASE FAN KIT 0 M REMS -X PANEL (SEE PLANS) CASE PLAN VIEW CASE FAN KIT 4' SPACE BETWEEN WALL AND CASE INTEGRAL TO CASE STRUCTURE BELOW. WALL BACK OF CASE BELOW INSTALL CASE MANUFACTURER FURNISHED 30' BLANK -OFF PANEL TO BLOCK OFF SPACE BETWEEN WALL AND CASE FROM FAN KIT TO END OF CASE. NOTCH BLANK-OFF PANEL AS NEEDED TO ACCOMMODATE PIPING OR WIRING CONNECTIONS. REFRIGERATION PIPING CONNECTION AT THE TOP OF THE CASE. REFRIGERATION CONTROL PANEL LOCATION DETAIL NOT TO SCALE - 3 ' 'ALL- THREAD' HANGER ROD %• FLEXIBLE ELASTOMERIC INSULATION, IN ACCORD WITH SPECIFICATION 24 0719, GLUE TO METAL STUD (TYPICAL) 2'x6' METAL STUD 2'x6' METAL STUD CUT TO LENGTH REFRIGERATION PIPES REFRIGERATION PIPE HANGER DETAIL REFRIGERATION PIPING UP IN FALSE COLUMN. SEE ARCHITECTURAL DRAWINGS FOR FALSE COLUMN. COORDINATE PIPING WITH PLUMBING PIPING AND ELECTRICAL CONDUITS ALSO LOCATED IN COLUMN. 3' NUT �' WASHER (TYPICAL) %' WASHER 2 -3/8' NUTS ROOF DECK 6' MAX. 6" MAX. P1000 UNISTRUT SUCTION AND LIQUID HEADER PIPING ON TOP OF CASE. BEAM CLAMP SHALL BE ATTACHED WITHIN 6' OF THE BAR JOIST PANEL POINT. %' 'ALL- THREAD' HANGER ROD GENERAL NOTES: A. ALL HANGERS AND HANGER SUPPORT SHALL COMPLY WITH REQUIREMENTS OF LOCAL CODE AUTHORITIES. B. NOTE: O AVERAGE PIPE SIZE = 1' O AVERAGE PIPE WEIGHT = 1 PLF O MAX NO. OF PIPES PER HANGER = 20 O TOTAL MAX WEIGHT = 100 LBS PER HANGER UNLESS APPROVED BY STRUCTURAL ENGINEER O BRACING NOT REQUIRED FOR PIPING 3' AND SMALLER. C. SEE 3/R521 FOR ALTERNATE DETAIL. NOT TO SCALE SET SUCTION AND LIQUID PIPING ON TOP OF 1" THICK BY 4" WIDE STRIP OF RIGID INSULATION SPACED EVERY 4' -0" ON TOP OF CASE. TYPICAL. INSTALL CASE MANUFACTURER FURNISHED TRIM PIECE ON TOP OF CASE. ---1 --1 - 7 / DAIRY CASE SEE DETAIL 5/R511 DUAL TEMP CASE / -- 1 CONNECT TO LIQUID AND SUCTION PIPING CONNECTIONS AT THE TOP OF THE CASE. TYPICAL. DAIRY CASE FROZEN CASE LINE UP ti —/i ELECTRONIC EVAPORATOR PRESSURE REGULATOR (EEPR). INSTALL ON CASES WHERE INDICATED BY THE REFRIGERATION SCHEDULES ON R601. SEE DETAIL 5/R511. 120v LIQUID LINE SOLENIOD INSTALLED ON TOP OF CASE (FOR LOOP PIPING AND CONDENSING UNIT SYSTEMS ONLY) I 1 / / / L -- RECEIVED NOV 19 2010 PERMIT CENTER CASE PIPING DETAIL 1 / / / / / II 'I I I / I I I L -- 1 / / / / L - -' INSTALL CASE MANUFACTURER FURNISHED FAN BLOWER KIT. FAN KIT IS 30' SHORTER THAN THE CASE. CENTER FAN KIT. INSTALL PER CASE MANUFACTURERS INSTRUCTIONS. FASTEN AND SEAL FAN KIT TO BOTH CASES. TYPICAL. i / / / / / / / L- L - -' 1 / / / / / INSTALL CASE MANUFACTURER FURNISHED 30' LONG BLANK -OFF PANEL. CUT BLANK -OFF INTO TWO 15' PIECES AND INSTALL AT EACH END OF FAN KIT. FASTEN AND SEAL TO BOTH CASES. NOTCH BLANK -OFF PANELS AS NEEDED TO ACCOMMODATE PIPING OR WIRING CONNECTIONS. TYPICAL. TGr 0-- NOT TO SCALE TARGET STORE SOUTH CENTER WA08 STORE T0627 VERSION MR2010_08 -06-10 TITLE REFRIGERATION 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL DETAILS / SHEET R511 n T -0627 SOUTH CENTER, WA NOT USED SIZES VARY NOT TO SLAB TO BE POURED AFTER REFRIGERATION PIPES ARE IN PLACE AND TESTED CONCRETE FLOOR SLAB, SEE PLAN SELECT GRANULAR FILL SEE SPEC'S FELT PAPER BOND BREAKER COMPACTED SAND FILL SCALE PVC PIPE, SEE 2/R401 FOR LOCATIONS REFRIGERATION PIPE JUNCTION BOX -III I _ -1 IIII -I I =1I =IIII II I I II =III =1 I- III III IIII 1= 1 =I I I -1 =II REFRIGERATION PIPE SLEEVE NOT TO SCALE CONCRETE FLOOR SLAB PVC SLEEVE (SCHEDULE 40) FOR REFRIGERATION PIPE. PVC PIPE TO BE PROVIDED BY REFRIGERATION CONTRACTOR COMPACTED SAND FILL REFRIGERATION CONTRACTOR TO INSTALL REFRIGERATION LINES %.0c ALL- THREAD HANGER ROD (TYP.) NOT TO SCALE UNISTRUT P6001 ATTACHED TO THE BOTTOM CORD(TYP.) ROOF JOIST (TYP.) SEE STRUCTURAL DRAWINGS FOR LOCATIONS. UNISTRUT ROOF JOIST BOTTOM CHORD 3/1?0 THRU -BOLT W/ 3/8' WASHER AND (2)3/8' NUTS 8'0 HANGER ROD 3/8' NUT, 1/2' WASHER 3/8' WASHER, (2) 3/8' NUTS EVAPORATOR COIL TIE WIRE (TYP.) PRODUCE STORAGE EVAPORATOR COIL SUPPORT DETAIL NOT TO SCALE NOT USED NOT TO SCALE RETAINER CLIP SENSING BULB INTERIOR OF LABELING ROOM SNAP COVER —� 3 /R° DRILLED HOLE IN INTERIOR WALL IIN/EXDTERIOR WALL /FT EXTERIOR OF LABELING ROOM THERMOMETER, MOUNT 5' AF . FIELD INSTALLED LABELING ROOM THERMOMETER NOT TO SCALE PIPE INSULATION FILL VOID WITH EXPANDING FOAM INSULATION CONCRETE ANCHORS FINISHED FLOOR I II DRILL OR CUT HOLE IN TOP OF BOX AS NEEDED FOR REFRIGERATION PIPES. POUROVER FRAME ASSEMBLY MODEL POL CRAIGG MFG CORP 19 HELEN AVE. EPHRATA, PA 17522 (717) 733 -1412 PROVIDED BY REFRIGERATION CONTRACTOR. TO REMS PANEL S } v I I C v REFRIGERATION PIPING PROVIDE PVC SLEEVE THROUGH FLOOR SLAB. SIZE AS REQUIRED. FLOOR SLAB DRILL OR CUT HOLE IN SIDE 17----- OF BOX AS NEEDED FOR PVC PIPES. REFRIGERATION UNDERGROUND BOX PVC PIPING SEAL PIPE PENETRATION PER DETAIL 14/R501 NOT TO SCALE SEAL PIPE PENTETRATION L7„-- PER DETAIL 9/R521 WALK -IN COOLER /FREEZER ROOF MOUNT TEMP SENSOR TO FAN GUARD WITH WIRE TIE. ATTACH CABLE TO EVAPORATOR HOUSING. AIR FLOW AIR FLOW f MINIMUM 6' HORIZONTAL SUCTION LINE SUCTION LINE P -TRAP MOUNT SUPPLIED TXV SENSING BULB AT 5 O'CLOCK POSITION ON HORIZONTAL SUCTION LINE. LOW VELOCITY COIL, SENSOR AND TXV MOUNTING DETAIL NOT TO SCALE BASE SEAL PENETRATIONS WITH SILICONE CAULK REFER TO SECTION 07 9200 '444[ LOW VOLTAGE CABLE. FINAL CONNECTION BY OTHERS. 10' FROM CONDUIT OR PIPING I< MINIMUM 6' FROM SEAM OR EDGE y PREVENT SILICONE CAULK AT TUBE FROM RUNNING INTO RF MOUNT ANTENNA BEZEL • YYY INSULATED CEILING PANEL A Al 1 r u I1 USE SUPPLIED SCREWS (4) TO it MOUNT ASSEMBLY TO WALK -IN CEILING PANEL. u I I II II CONTINUOUS 1 /4' BEAD OF SILICONE CAULK AROUND TOP OF ACCESS POINT MOUNT AND AT TUBE RF MODULE ASSEMBLY INSTALLED TIGHT TO WALK -IN CEILING. NOTE: 1. OPENING FOR RF MODULE TUBE TO BE 1 I /8' DIA. 2. DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS. 3. DO NOT INTERFERE WITH PLUMBING OR ELECTRICAL INSTALLATIONS. 4. DO NOT INSTALL DIRECTLY IN FRONT OF EVAPORATOR COIL. 5. RF UNIT NOT TO INTERFERE WITH PRODUCT MOVEMENT. 6. SEE R421 FOR APPROXIMATE LOCATIONS IN WALK -INS. RF MODULE INSTALLATION NOT TO SCALE ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y:\ Target\_Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r521.dgn TARGET TYPICAL REFRIGERANT PIPING LINE PIPE INSULATION SEE 8/R511 FOR DETAILS �� —ON CONNECTING THE THREADED ROD TO THE STRUCTURE ABOVE. �— THREADED ROD REFRIGERATION LINE SUPPORT REFRIGERATION PIPE WITH INSULATION AND PVC JACKET UNISTRUT HANGER NOTES: A. ALTERNATE PIPE SUPPORTS NOT APPROVED FOR CEILINGS WITH RETURN AIR PLENUM. HEIGHT REQUIRED TO 4_,.----UNISTRUT SUPPORT BOLT UNISTRUT TO BASE. REFRIGERATION LINE SUPPORT REFRIGERATION PIPE HANGER DETAIL (ALTERNATE) INTERMEDIATE TRAPS REQUIRED AT 15'-0' FROM BASE OF SUCTION RISER — P -TRAP REQUIRED AT BASE OF ALL SUCTION RISERS EXCEEDING 6' -0' IN LENGTH 8' MAX 12' MAX a �- REFRIGERATION RISERS WITH INSULATION. FLOOR RISER SUPPORT DETAIL NOT TO SCALE \"------ 1% UNISTRUT REFRIGERATION BOX • r , - =+ • • 1 r`` -- • I r--= • -- • 1 r`, - =+ S. .� WALL THAT SEPARATES SALES j F FLOOR AND STOCK ROOM VERSION mum) 08 FALSE __ – COLUMN BP -0.0 . 8' MAX 12' MAX a �- REFRIGERATION RISERS WITH INSULATION. FLOOR RISER SUPPORT DETAIL NOT TO SCALE \"------ 1% UNISTRUT REFRIGERATION BOX • r , - =+ • • 1 r`` -- • I r--= • -- • 1 r`, - =+ S. .� WALL THAT SEPARATES SALES j F FLOOR AND STOCK ROOM VERSION mum) 08 11-09-10 BP -0.0 . CONFIGURATION LL DETAILS DRAWN BY TLY MOUNT HANGER BRACKET AS CLOSE TO WALL AS POSSIBLE. a, LA.( CHECKED BY JA ARCHITECTS PROJECT NO. NOT TO SCALE HANGER BRACKET SEE DETAIL 15/R501 TYP. WALK -IN CEILING PANEL JOINT SEE DETAIL 15/R501 UNISTRUT MOUNTED TO THE BOTTOM OF CHORD INSTALLED PERPENDICULAR TO THE JOIST. FOR MOUNTING SEE 13/R521. TYP(7). NOTES: A. SEE KYSOR PANEL SYSTEMS WALK -IN ASSEMBLY PLANS AND DETAILS FOR LOCATIONS AND QUANITIES OF HANGER BRACKETS. REAR —FED DAIRY COOLER ROOF PANEL SUSPENSION DETAIL (OR ROOF PANEL SPANs GREATER THEN 19' LONG) NOT TO SCALE DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS VERSION mum) 08 11-09-10 BP -0.0 PERMIT SET CONFIGURATION LL DETAILS DRAWN BY TLY CHECKED BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 1V52010 TYPICAL REFRIGERANT PIPING LINE 4' x 4' TREATED WOOD MIM. 2' LONG WITH WRAPED WITH MEMBRANE SEE ARCH DETAIL 9/A140 FOR DETAILS ON THE WOOD IS WRAPED WITH MEMBRANE AND CONECTED TO THE ROOF. 4 REFRIGERATION ROOF PIPE SUPPORT DETAIL (ALTERNATE) NOT TO SCALE 3/8'0 ALL -THREA HANGER ROD (TYP.) NOT TO SCALE UNISTRUT P6001 ATTACHED TO BOTTOM CHORD (TYP.) ROOF JOIST (TYP.) SEE STRUCTURAL DRAWINGS FOR LOCATIONS. REVIEWED FOR CODE COMPLIANCE APDPAVED DEC 1 u a: id City of Tukwila BUILDING DIVISION UNISTRUT ROOF JOIST BOTTOM CHORD 3/8'0 THRU -BOLT W/ 3/8' WASHER AND (2)3/8' NUTS %'o HANGER ROD SEE 15/R501 FOR BRACKET MOUNTING DETAIL. SPACE PER KYSOR PANELS SYTEMS ASSEMBLY PLANS AND 12/R521. WALK -IN ROOF PANEL REAR —FED DAIRY COOLER ROOF PANEL SUSPENSION DETAIL (OR ROOF PANEL SPANs GREATER THEN 19' LONG) NOT TO SCALE 1)& 0.-151 TARGET STORE SOUTH CENTER WA08-06-10 STORE T0627 VERSION mum) 08 TITLE REFRIGERATION 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL DETAILS RPC9VPD NOV i 9 2010 PERMIT CE J -EF SHEET R521 T -0627 SOUTH CENTER, WA ! T -0627 South Center WA - P09.400 2011 MR -RS RE Owner Furnished 100 Degree Ambient Temperature ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT (RTCR -1) AND MARKET AREA REFRIGERATION SCHEDULE Equipment Revised: 10/6/10 DEFROST EVAPORATOR COILS PIPING CIRCUIT NUMBER OF DOORS CASE MANUF. CASE MODEL USE WALK -IN ROOM TEMP. CASE EVAP. DISCHARGE AIR TEMP. BTUH/DOOR BTUH EVAP TEMP. CONTROL DEFROST # DEFROST /DAY DEFROST DURATION ELECT. DEFROST DATA AMP (VOLT/PH) QUANTITY MANUF. MODEL DIMENSION BTUH@ 1 ° TD -EACH °TD EVAP FAN ANAIN HEATERS ELECT. DATA AMP /VOLT /PHI TOTAL EQUIV. PIPE LENGTH (FT) SUCTION LINE SIZE O.D. (IN) SUCTION PRESS. DROP (PSI) SUCTION TEMP. CHANGE (°F) LIQUID LINE SIZE O.D. (IN) LIQUID PRESS. DROP (LBS) SUCTION RISER LINE SIZE O.D. (IN) SUCTION RISER VELOCITY (FT/MIN) HOT GAS LINE SIZE O.D. (IN) BY RACK MANUF. ICE CREAM DAIRY ICE CREAM DAIRY ICE CREAM DAIRY ICE CREAM DAIRY ICE CREAM DAIRY A01 BELOW HG 3 20 -- 89 1 1/8 0.8 1.0 5/8 -7.0 7/8 - 1032 - 5/8 A01 -A 8 HILL PHOENIX OWIZ D.T. - FF /MT -6 / 27 295 2360 -12 EEPR @ CASE - -- - - - - - - - - -- A01-B 8 HILL PHOENIX OWIZ D.T. - FF /MT -6 / 27 295 2360 -12 EEPR @ CASE - -- - - - - - - - - -- A01-C 1 HILL PHOENIX OWEZ D.T. - FF /MT -6 / 27 2665 2665 -12 EEPR @ CASE - - - - - -- - - - - -- A01-D 1 HILL PHOENIX OWEZ D.T. - FF /MT -6 / 27 2665 2665 -12 EEPR @ CASE - - - - - -- - - - - - A02 8 HUSSMANN RLN ICE CREAM -12 1400 11200 -19 EEPR HG 1 20 - 50 1 1/8 0.6 0.8 5/8 -7.0 7/8 - 1298 - 5/8 A03 9 HUSSMANN RLN ICE CREAM -12 1400 12600 -19 EEPR HG 1 20 - 71 1 1/8 1.0 1.4 5/8 -7.0 7/8 - 1460 - 5/8 A04 8 HUSSMANN RLN ICE CREAM -12 1400 11200 -19 EEPR HG 1 20 - 50 1 1/8 0.6 0.8 5/8 -7.0 7/8 - 1298 - 5/8 A05 9 HUSSMANN RLN ICE CREAM -12 1400 12600 -19 EEPR HG 1 20 - 71 1 1/8 1.0 1.4 5/8 -7.0 7/8 - 1460 - 5/8 A06 8 HUSSMANN RLN ICE CREAM -12 1400 11200 -19 EEPR HG 1 20 -- 56 1 1/8 0.5 0.9 5/8 -7.0 7/8 - 1298 - 5/8 A07 9 HUSSMANN RLN ICE CREAM -12 1400 12600 -19 EEPR HG 1 20 -- 70 1 1/8 1.0 1.4 5/8 -7.0 7/8 - 1460 - 5/8 A08 8 TYLER P5FGN(ER) ICE CREAM -12 1509 12072 -23 EEPR HG 1 20 -- 56 1 1/8 0.8 1.2 5/8 -7.0 7/8 - 1540 - 5/8 A09 9 HUSSMANN RLN ICE CREAM -12 1400 12600 -19 EEPR HG 1 20 -- 70 1 1/8 1.0 I A 5/8 -7.0 7/8 - 1460 - 5/8 ABO1 2 HUSSMANN RLN D.T. - IC /DAIRY -12 / 32 1400 890 2800 1780 -19 27 EEPR HG /OT 1 / 1 20 / 60 -- 62 5/8 1.1 t6 5/8 -7.1 1/2 3/8 1082 737 5/8 ABO2 2 HUSSMANN RLN D.T. - IC /DAIRY -12 / 32 1400 890 2800 1780 -19 27 EEPR HG /OT 1 / 1 20 / 60 -- 50 5/8 0.9 1.2 5/8 -7.1 1/2 3/8 1082 737 5/8 ABO3 2 HUSSMANN RLN D.T. - IC /DAIRY -12 / 32 1400 890 2800 1780 -19 27 EEPR HG /OT 1 / 1 20 / 60 -- 56 5/8 1.0 1.4 5/8 -7.1 1/2 3/8 1082 737 5/8 ABO4 3 TYLER P5FGN(ER) D.T. - IC /DAIRY -12 / 30 1509 874 4527 2622 -23 20 EEPR HG /OT 1 / 1 201 60 - 94 7/8 1.2 1.9 5/8 -7.0 5/8 3/8 1200 1100 5/8 ABO5 3 TYLER P5FGN(ER) D.T. - IC /DAIRY -12 / 30 1509 874 4527 2622 -23 20 EEPR HG /OT 1 / 1 20 / 60 -- 94 7/8 1.2 1.9 5/8 -7.0 5/8 3/8 1200 1100 5/8 AB06 SPARE D.T. - IC /DAIRY EEPR HG /OT 1 I 1 20 / 60 -- 5/8 ABO7 SPARE D.T. - IC /DAIRY EEPR HG /OT 1 / 1 20 / 60 -- 5/8 SUCTION GROUP A A A A A A A CONDENSER SUMMARY SYSTEM SUMMARIES RTCR ELECTRICAL REQUIREMENTS COMPRESSOR ZF18KVE -TFD ZF24KVE -TWD ZF24KVE -TW D W ZF24KVE -TD ZF24KVE -TWD 5 Equipment Value 120 Volt 460 Volt COMPRESSOR HORSEPOWER 6 7.5 7.5 7.5 7.5 36 SYSTEM A SUCTION GROUP TOTAL LOAD (BTUH) SUBCOOLER LOAD (BTUH) NON - SUBCOOL CAPACITY (BTUH) SUBCOOLED CAPACITY (BTUH) NON - SUBCOOL SAFETY FACTOR SUBCOOLED RTCR MCA 24.0 78.6 REFRIGERANT R -404A R-404A R-404A R-404A R-404A R-404A MANUFACTURER BOHN SAFETY Totals MOPD 30.0 90 REFRIGERANT CLASSIFICATION Al Al Al Al Al Al MODEL BNL- D04 -A028 FACTOR FLA 75.3 CONDENSING TEMP ( °F) 110 110 110 110 110 110 REJECTION (BTUH) 250880 A 123576 44700 98100 142800 - 20.62% 15.56% SUCTION TEMP ( °F) -26 -26 -26 -26 -26 -26 FINS / INCH 10 LIQUID TEMP AT SUBCOOLER ( °F) 40 40 40 40 40 40 BTUH / °TD 27300 Compressors RLA 62.1 LIQUID TEMP AT TXV ( °F) 50 50 50 50 50 50 °TD 9.2 ESTIMATED REFRIGERANT CHARGE (LBS) NONSUB. COMP. CAPACITY (BTUH) 17300 20200 20200 20200 20200 98100 SIZE 88 "x112 "x49.13" MINIMUM REQ. RECEIVER 80% Condenser FLA 13.0 13.2 INPUT POWER (KW) 5.10 6.20 6.20 6.20 6.20 29.9 VOLTAGE 460 CIRCUITS RACK CONDENSER ESTIMATED 80% RECEIVER HOLDING RLA (AMP) 9.30 13.20 13.20 13.20 13.20 62.1 FLA (AMP) 13.2 TOTAL CAPACITY CHARGE HEAT OF REJECTION (BTUH) 42600 50600 50600 50600 50600 245000 CHARGE (LBS) 170 (Ibs) (Ibs) SUB. COMPRESSOR CAPACITY (BTUH) 25200 29400 29400 29400 29400 142800 WEIGHT (LBS) 1340 295 196 170 661 306 585 SUBCOOLER LOAD (BTUH) 7900 9200 9200 9200 9200 44700 FANS 2x2 UN LOADER No No No No No FAN (RPM) 830 ELEVATION (ft) 1000 NOTES: 1) Two -Piece Low Temperature RTCR. Single suction compressor rack without 3 -Way DT valves. 2) Two -Piece RTCR requires piping and electrical connections between compressor and condenser sections. (2) 1 -3/8" discharge lines, 1 -1/8" liquid line, 7/8" receiver pressurization line, 5/8" high/low bypass line, 1/2" condenser pump -out line. See manufacturer shop drawing for connection locations. 3) Circuits A08 - Reused Tyler N5FGN/P5FGN cases - Convert cases from EL to HG defrost. Install new defrost termination sensors. Parts provided by Target. " T -0627 South Center WA - P09.400 2011 MR -I Owner Furnished 100 Degree Ambient Temperature ROOFTOP COMPRESSOR RACK AND CONDENSER UNIT (RTCR -2) AND MARKET AREA REFRIGERATION SCHEDULE Equipment Revised: 10/06/10 DEFROST EVAPORATOR COILS PIPING CIRCUIT NUMBER OF DOORS CASE MANUF. CASE MODEL USE WALK -IN ROOM TEMP. CASE EVAP. DISCHARGE AIR TEMP. BTUH /DOOR BTUH EVAP TEMP. CONTROL DEFROST # DEFROST /DAY DEFROST DURATION ELECT. DEFROST DATA AMP (VOLT/PH) QUANTITY MANUF. MODEL DIMENSION BTUH@ 1° TD -EACH ° TD EVAP FAN ELECT. DATA AMP (VOLT/PH) TOTAL EQUIV. PIPE LENGTH (FT) SUCTION LINE SIZE O.D. (IN) SUCTION PRESS. DROP (PSI) SUCTION TEMP. CHANGE (°F) LIQUID LINE SIZE 0.D. (IN) LIQUID PRESS. DROP (LBS) SUCTION RISER LINE SIZE O.D. (IN) SUCTION RISER VELOCITY (FT /MIN) HOT GAS LINE SIZE O.D. (IN) BY RACK MANUF. ICE CREAM DAIRY ICE CREAM DAIRY ICE CREAM DAIRY ICE CREAM DAIRY ICE CREAM DAIRY B01 6 HILL PHOENIX O5M DAIRY 34 1650 9900 24 EEPR OT 6 26 47 7/8 2.0 1.4 1/2 -5.6 -- 5/8 - 1422 -- B02 32 HILL PHOENIX 05M PRODUCE 36 1650 52800 24 EEPR OT 6 26 47 1 5/8 0.9 0.6 5/8 -4.3 -- 1 3/8 - 1408 -- B03 _ 12 HILL PHOENIX 05M DAIRY 34 1650 19800 24 EEPR OT 6 26 47 1 1/8 1.3 0.9 1/2 -5.0 -- 7/8 - 1371 -- B04 20 HILL PHOENIX 05M MEAT 30 1650 33000 24 EEPR OT 6 26 64 1 3/8 1.3 0.9 1/2 -3.1 -- 1 1/8 - 1340 -- B05 24 HILL PHOENIX o5M MEAT 30 1650 39600 24 EEPR OT 6 26 90 1 518 1.0 0.7 5/8 -4.1 - 1 3/8 - 1056 -- B06 20 HILL PHOENIX O5M DAIRY 34 1650 33000 24 EEPR OT 6 26 64 1 3/8 1.3 0.9 1/2 -3.1 -- 1 1/8 - 1340 -- B07 24 HILL PHOENIX 05M DAIRY 34 1650 39600 24 EEPR OT 6 26 90 1 5/8 1.0 0.7 5/8 -4.1 -- 1 3/8 - 1056 -- B08 5 HUSSMANN RMN BEER 32 890 4450 27 EEPR OT 1 60 104 5/8 3.0 2.3 1/2 -5.7 -- 1/2 - 964 - B09 7 TYLER P5NGN(ER) DAIRY 30 874 6118 20 EEPR OT 1 60 104 7/8 2.0 1.5 1/2 -5.6 -- 5/8 - 957 -- 810 9 HUSSMANN RMN BEER 32 890 8010 27 EEPR OT 1 60 152 7/8 1.9 1.3 1/2 -5.3 3/4 - 736 - B11 SPARE 24 EEPR OT - B12 SPARE 24 EEPR OT -- nYIGVV�� ®, (� Y G R CODE COMPLIANCE ���® UE C v 2u ) (�/ �� �(,� City I(VII,lla BUILDING DIVISinnl SUCTION GROUP B B B B B B B CONDENSER SUMMARY SYSTEM SUMMARIES RTCR ELECTRICAL REQUIREMENTS COMPRESSOR ZB45KCE -TFD ZB56KCE -TWD ZB56KCE-1WD ZB56KCE -TWD ZB56KCE -TWD 5 SYSTEM B Equipment Value 120 Volt 460 Volt COMPRESSOR HORSEPOWER 6 7.5 7.5 7.5 7.5 36 MANUFACTURER BOHN SUCTION GROUP TOTAL LOAD (BTUH) SUBCOOLER LOAD (BTUH) NON- SUBCOOL CAPACITY SUBCOOLED CAPACITY (BTUH) NON- SUBCOOL SAFETY SUBCOOLED RTCR MCA 24.00 97.7 REFRIGERANT R-404A R-404A R-404A R-404A R-404A R-404A MODEL BNL- D06 -A042 SAFETY Totals MOPD 30.00 110 REFRIGERANT CLASSIFICATION Al Al Al Al Al Al REJECTION (BTUH) 394598 FACTOR FLA 92.7 CONDENSING TEMP ( °F) 110 110 110 110 110 110 FINS /INCH 10 B 246278 267400 8.58% SUCTION TEMP ( °F) 18 18 18 18 18 18 BTUH I °TD 40900 NONSUB. COMP.CAPACITY (BTUH) 45400 55500 55500 55500 55500 267400 °TD 9.6 Compressors RLA 72.9 INPUT POWER (KW) 5.55 7.25 7.25 7.25 7.25 34.55 SIZE 88 "x165 "x49.13" ESTIMATED REFRIGERANT CHARGE (LBS) RLA (AMP) 10.10 15.70 16 16 16 72.9 VOLTAGE 460 ESTIMATED TOTAL MINIMUM REQ. RECEIVER Condenser FLA 19.8 HEAT OF REJECTION (BTUH) 64350 80250 80250 80250 80250 385350 FLA (AMP) 19.8 CIRCUITS RACK CONDENSER 80% 80% HOLDING UNLOADER No No No No No CHARGE (LBS) 160.0 RECEIVER CHARGE WEIGHT (LBS) 2200 CAPACITY (Ibs) (lbs) NOTES FANS 2x3 284 196 160 640 312 585 1) Two-Piece Med. Temperature RTCR. Single suction compressor rack. FAN (RPM) 830 2) Two-Piece RTCR requires piping and electrical connections between compressor and condenser sections. (2) 2-1/8" discharge lines, 1 7/8" receiver pressurization line, 5/8" high/low bypass line, 1/2" condenser pump -out line. See manufacturer shop drawing for connection locations. 518" liquid line, ELEVATION (ft) 1000 3) Circuits B09 - Reused Tyler N5NGN /P5NGN MT cases - Convert cases to R404a. Parts by Refrig Contractor. T-0627 South Center WA - P09.400 2011 MR CU Schedule 100 Ambient Revised: 10/7/2010 REFRIGERATION CASE AND WALK -IN COOLER/FREEZER SCHEDULE CIRCUIT USE SIZE TOTAL LOAD (BTUH) BOX TEMP. EVAP. TEMP. CONTROL WALK -IN EVAPORATOR COILS DEFROST ELECTRICAL AMPS CASES (120V) EVAP. COILS (TOTAL) QUAN. MANUF. MODEL CAPACITY BTUH / 1 °TD °TD DIMENSION TYPE QUANT. & DURATION FANS LIGHTS ANTI -SWEAT (DOORS) ANTI -SWEAT (FRAMES) ANTI -SWEAT (TOTAL) FAN ELECT. DEFROST CO1 WALK -IN FREEZER 20x20x9.5 25400 -15 -23 CPC, LL SOLENOID 2 KRACK KR54E185EAK 1850 8.2 103.75 "X15.32 "X15.9" ELECT 2 @ 20 - - - - - 3.0 (208V/1) 29 (208V/3) DO1 WALK -IN COOLER 15x20x9.5 18600 36 25 CPC, LL SOLENOID 2 KRACK KR26A- 105EBX 1050 10.7 47.13 "X15.32 "X15.9" OT 2 @ 20 - - - - - 2.4 (115V/1) - D02 WALK -IN MEAT COOLER 11x16x9.5 13400 28 19 CPC, LL SOLENOID 1 KRACK GL54D- 175EAA 1750 8.8 103.75 "X28.75 "X12.25" ELECT 2 @ 20 - - - - - 1.65 (208V/1) 17.4 (208V/1) D03 WALK -IN PRODUCE COOLER 11x16x9.5 11500 40 31 CPC, LL SOLENOID 1 KRACK GL46A- 180EBX 1800 8.4 85.75 ")28.75 "X12.25" OT 2 @ 20 - - - - - 3.2 (115V/1) - D04 DRY STORAGE 246 SQ.FT. 15990 58 37 CPC, LL SOLENOID 1 KRACK GL26A -90EBX 900 21.2 49.75 ")28.75 "X12.75" OT 4 @ 50 - - - - -- 1.3 (115/1) - CONDENSING UNIT SCHEDULE COND. UNIT CIRCUIT MANUF. MODEL COMP. MODEL REFRIG. REFRIG CLASS COMP. HP AMBIENT TEMP. ACTUAL COND. TEMP TOTAL LOAD (BTUH) CAPACITY (BTUH) SUCTION TEMP. CONNECTION MAXIMUM DEFROST AMPS ELECTRICAL AMPS RECEIVER WEIGHT (LBS) DIMENSIONS LxWxH VOLT. COMP. RLA COND. FAN FLA TOTAL CAPACITY AT 80% SOUND (DBA) SUCTION LIQUID MCA MOPD FULL (LBS) CU -1 C01 HUSSMANN HTHD- 0750LSK -EF -A 3DBF33KE R-404A Al 7.5 100 °F 108 25400 30201 -25 1 3/8" 5/8" 29 208 -230/3 31.5 7.0 58.8 80.0 73.2 1250 80.57 "X35.08 "X49.49" CU -2 DO1 HUSSMANN HTHZ- 0300MSK -BE -A ZB2IKCE R-404A Al 3.0 100 °F 113 18600 22450 23 7/8" 1/2" - 208 -230/3 11.1 2.0 18.8 30 47.9 650 44.57"X35.11"X49.51" CU -3 D02 HUSSMANN HTHZ 0200MSK -BE -A ZBI5KCE R-404A Al 2.0 100 °F 109 13400 15387 17 7/8" 1/2" 17.4 208 -230/3 9.3 2.0 22.5 30.0 47.9 650 44.57 "X35.11 "X49.51" CU-4 D03 HUSSMANN HTHS- 0200MSK -BE -A KAKA -020E R-404A Al 2.0 '100 °F 110 11500 15180 29 7/8" 1/2" - 208 -230/3 6.8 2.0 13.8 20.0 47.9 550 44.57 "X35.11 °X49.51" CU -5 D04 HUSSMANN HTHZ- 0200MSK -BE -A ZBI5KCE R-404A Al 2.0 100 °F 110 15990 19048 29 7/8" 1/2" 208 -230/3 9.3 2.0 16.3 20.0 47.9 650 44.57 "X35.11 "X49.51" LINE SIZING AND ESTIMATED REFRIGERANT CHARGE (POUNDS) 3 REFRIGERATION LINE SIZES RECEIVER CIRCUIT EVAP. CHARGE EQUIVALENT SUCTION LINE LIQUID LINE SUCTION RISER CONDENSER SEAL CHARGE TOTAL CHARGE CAPACITY 80% w Z (LBS) LENGTH SIZE TEMP. DIFF. PRESS. DIFF. VEL. FT /MIN EST. CHARGE SIZE EST. CHARGE SIZE VEL. FT /MIN EST. CHARGE CHARGE (LBS) x CO1 10.7 45 2 1/8 0.5 0.3 981 0.57 5/8 4.64 1 5/8 1706 0.164 30.5 7.3 54.3 73.2 1- DO1 3.7 50 1 1/8 1.2 1.7 893 0.34 1/2 3.20 7/8 1522 0.102 15.64 4.8 29.9 47.9 ,°n D02 6.2 30 1 1/8 0.4 0.6 696 0.34 1/2 1.92 7/8 1186 0.102 15.64 4.8 32.2 47.9 N D03 3.9 32 1 1/8 1.5 2.1 532 0.34 1/2 2.05 5/8 1883 0.050 15.64 4.8 29.8 47.9 0 004 3.9 32 1 1/8 0.3 0.6 590 0.34 1/2 2.05 7/8 1007 0.102 15.64 4.8 26.8 47.9 Rf �� 7 I' NOV 19 2010 '''11) & I 0 1 PERMIT CENTER l ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 . 406.454.1873 WWW.CTAGROUP.COM fC.Ai C. ... G�o� y ti �, A� 4/R�° 4ONALE4G DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS TARGET STORE SOUTH CENTER WA 301 STRAN D E R BLVD TUKWIIA WA 98188 STORE T0627 VERSION MR2010 08 08-06-10 TITLE SHEET 1 -0g 10 BP-3.0 PERMIT SET L J J DRAWN BY TLY R E F R I G E RAT I O N O - - 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 SCHEDULES CHECKED BY JA PROJECT CODE 270627 CONFIGURATION LL ARCHITECTS PROJECT NO. // --.5 !D Y: \_Target\_Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r601.dgn nameofpersonplotting 1V52010 GENERAL NOTES: A. ALL REMS PANELS, CABLE AND COMPONENTS ARE FURNISHED BY REMS VENDOR. B. REMS -1 PANEL (EINSTEIN PANEL) IS LOCATED IN ROOM #u #. NEW REMS -1 PANEL IS INSTALLED AND POWERED (120 VAC) BY ELECTRICAL CONTRACTOR. VERIFY EXACT LOCATION ON ELECTRICAL PLANS. SEE EMC DRAWINGS FOR CONNECTIONS TO REMS -1. C. REMS -2 IS LOCATED ON TOP OF WALK -IN COOLER /FREEZERS AND IS INSTALLED AND POWERED (120 VAC & 208 VAC) BY ELECTRICAL CONTRACTOR. D. REMS -3 AND REMS -4 PANELS ARE LOCATED ON TOP OF SALES FLOOR CASES AND ARE INSTALLED AND POWERED (120 VAC) BY ELECTRICAL CONTRACTOR. INSTALL PANELS SO THEY ARE HIDDEN FROM VIEW. SEE 1/R401. E. LOW VOLTAGE CABLE INSTALLED BY ELECTRICAL CONTRACTOR, TERMINATION CONNECTIONS BY REFRIGERATION CONTRACTOR. F. DIV 26 ELECTRICAL CONTRACTOR INSTALLS ALL REMS PANELS AND DOOR SWITCHES AND ALARM PANELS. G. DIV 24 REFRIGERATION CONTRACTOR INSTALLS ALL SENSORS, LEAK TRANDUCERS AND LEAK INDICATORS WITH THE EXCEPTION OF CASE TEMPERATURE SENSORS WHICH ARE FACTORY INSTALLED BY THE CASE MANUFACTURER. H. FOR ADDITIONAL INFORMATION FOR THE INSTALLATION OF REMS COMPONENTS, SEE DETAILS ON R501, R511 AND R521. I. REMS DRAWINGS PROVIDED BY ENERGY MANAGEMENT CONSULTANTS. CONTACT TECH. SUPPORT o 608- 822 -3550. REFRIGERATION CONTRACTOR TO REFER TO REMS DRAWINGS FOR FINAL CONNECTIONS. J. SEE DETAIL 6/R501 FOR EVAPORATOR ELECTRIC DEFROST TERMINATION SENSOR DETAIL. K. THE LIGHT /DOOR HEATER CONTROL PANEL, REMS -L /DH, CONTROLS THE DISPLAY LIGHTS FOR ALL CASES AND ANTI - SWEAT DOOR HEATERS FOR THE ICE CREAM AND DAIRY CASES. THE DUAL TEMPERATURE CASES COME FURNISHED WITH INTEGRAL DOOR AND FRAME ANTI -SWEAT HEATER CONTROLS LOCATED IN THE DOORS. L. THE POWER FOR THE FREEZER AND MEAT COOLER EVAPORATOR COIL FANS IS ROUTED THROUGH CONTACTORS IN THE REMS -2 PANEL. THE CONTACTOR CUTS POWER TO THE FANS WHEN THE WALK -IN IS IN DEFROST. REFRIGERATION SYMBOLS: ROOM # ZONE CAO J SYSTEM NUMBER JACKET COLOR REMS3 REMOTE PANEL AT MARKET CASES CC) GROCERY ZONE TEMP & HUMIDITY SENSOR ® DISCHARGE AIR TEMP. SENSOR INSTALLED BY REFRIGERATION CONTRACTOR ICE CREAM FREEZER REMS -2 LOCATED ABOVE WALK -IN PRODUCE COOLER 2 REMS4 REMOTE PANEL AT MARKET CASES BLUE 3 INSTALLED BY REFRIGERATION CONTRACTOR PRODUCE COOLER (P400) HEMS- I /nH LIGHT /DOOR HEATER CONTROL PANEL INSTALLED BY REFRIGERATION CONTRACTOR R1 MT TEMPI AIR WALK -INS) 5 INSTALLED BY REFRIGERATION CONTRACTOR LEAK D TECTOR OPERATION ACUU VACUUM PANEL AT VACUUM PUMP BLUE RTCR -2 LOCATED ON ROOF D1 DEFROST TERMINATION SENSOR (LOW TEMP /DT CASES & 0 ALARM ALARM ANNUNCIATOR PANEL WALK -INS) .>. REFRIG. TRANSDUCER SUCTION TEMP SENSOR (LOOP STORES ONLY) 22/2 ii, REMS CABLE NUMBER ® REMOTE CONDENSER/ SW /DA DOOR SWITCH & DOOR ALARM HORN & STROBE COMPRESSOR UNITS RLI REFRIGERANT LEAK INDICATOR HORN /STROBE ZONE TEMPERATURE AND HUMIDITY SENSOR ROOFTOP COMPRESSOR RACK T H © IL ROOFTOP COMPRESSOR RACK ilir CONDENSER UNIT REMS1 EINSTEIN PANEL ELECTRONIC EVAPORATOR PRESSURE REGULATING VALVE. REMS2 REMOTE PANEL AT WALK -IN COOLER /FREEZER REMS CABLE MARKER LEGEND: REMS PANEL INPUT (I) NUMBER _ I OUTUT (0) 22/4 WIRE TYPE LEAK DETECTOR LOCATION AND ZONE IDENTIFICATION GENERAL NOTE: ALL LEAK DETECTOR TRANSDUCERS ARE TO BE INSTALLED 12 " -18" AFF IN THE COOLERS AND FREEZERS. LOCATION ROOM # ZONE REMARKS JACKET COLOR DAIRY COOLER REMS -2 LOCATED ABOVE WALK -IN PRODUCE COOLER 1 INSTALLED BY REFRIGERATION CONTRACTOR ICE CREAM FREEZER REMS -2 LOCATED ABOVE WALK -IN PRODUCE COOLER 2 INSTALLED BY REFRIGERATION CONTRACTOR MEAT COOLER (P400) BLUE 3 INSTALLED BY REFRIGERATION CONTRACTOR PRODUCE COOLER (P400) 0 4 INSTALLED BY REFRIGERATION CONTRACTOR LABELING ROOM (P400) 22/2 5 INSTALLED BY REFRIGERATION CONTRACTOR LEAK D TECTOR OPERATION COOLERS /FREEZERS: REFRIGERANT LEAK TRANSDUCERS CONTINUALLY MONITOR REFRIGERANT LEVELS WITT-IIN COOLER/FREEZER SPACES. IF A REFRIGERANT LEVEL OF 65 PPM IS DETECTED IN A WALK -IN COOLER/FREEZER REFRIGERANT FLOW TO THAT BOX IS STOPPED USING A SOLENOID VALVE LOCATED ADJACENT TO BOX ADDITIONALLY LEAK HORN /STROBE INDICATORS EXTERIOR AND INTERIOR TO THE BOX ARE ACTIVATED. THE HORN WILL SOUND UNTIL THE ALARM PANEL IS SILENCED VIA THE PUSH BUTTON, OR THE ALARM IS ACKNOWLEDGED WITHIN THE REFRIGERATION CONTROL SYSTEM. THE STROBES WILL CONTINUE TO REMAIN ACTIVE UNTIL THE REFRIGERATION LEVEL HAS FALLEN BELOW 70 PPM. ALARM WILL AUTOMATICALLY BE ROUTED TO TARGET FACILITIES MANAGEMENT OPERATION CENTER (FMOC). FMOC TECHNICIAN WILL CONTACT LEAD ON DUTY (LOD) TO ENSURE THAT ROOM(S) REMAIN UNOCCUPIED. LEAK HORN /STROBE INDICATORS ARE LABELLED THAT BOX SHOULD NOT BE OCCUPIED WHEN LIGHT /STROBE IS ACTIVE AND ARE INSTALLLED IMMEDIATELY ADJACENT TO THE COOLER/FREEZER DOOR ON THE INTERIOR AND EXTERIOR. -- - - - - - - I I- —I -- -�- - -- ELECTRICAL ROOM 129 11 11 11 11 II REMS2 �1 L 22 /W REVItWtD FOR— CODE COMPLIANCE aDDRIIIWED u 2i J TO RTCR -1 TYP. OF 5 TO RTCR -1 TYP. OF 3 ... -'L'L L" TO RTCR -2 TYP. OF 5 TO RTCR -2 TYP OF 3 TO REMS1 SEE 1/R611 (B02) (BO2) (B02) � (B�13) 1 1 1 1 1 1 tt I:i REMS ROOFTOP COMPRESSOR AND CONDENSOR UNIT CONRTOL WIRING PLAN NOT TO SCALE 1di Iuj ALARM ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target\_Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r611.dgn TARGET EXISTING ALARM PANEL TO REMAIN. VERIFY EXISTING ALARM PANEL LOCATIONS REMS CONTROL WIRING PLAN DATE ISSUED NOVEMBER 9TH, 2010 COMMUNICATION NETWORK CABLE SCHEDULE FROM TO REMS CABLE REMS CABLE # JACKET COLOR REMS -1 (EINSTEIN PANEL) LOCATED IN ROOM 129 REMS -2 LOCATED ABOVE WALK -IN PRODUCE COOLER 22/2 0 BLUE REMS -2 LOCATED ABOVE WALK -IN PRODUCE COOLER REMS -3 LOCATED ABOVE SALES FLOOR CASES 22/2 0 BLUE REMS -3 LOCATED ABOVE SALES FLOOR CASES REMS -4 LOCATED ABOVE SALES FLOOR CASES 22/2 0 BLUE REMS -4 LOCATED ABOVE SALES FLOOR CASES REMS -2 LOCATED ABOVE WALK -IN PRODUCE COOLER 22/2 0 BLUE REMS -1 (EINSTEIN PANEL) LOCATED IN ROOM 129 RTCR -2 LOCATED ON ROOF 22/2 0 BLUE RTCR -2 LOCATED ON ROOF RTCR -2 -CU LOCATED ON ROOF 22/2 0 BLUE RTCR -2 -CU LOCATED ON ROOF RTCR -1 LOCATED ON ROOF 22/2 0 BLUE RTCR -1 LOCATED ON ROOF RTCR -1 -CU LOCATED ON ROOF 22/2 0 BLUE ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target\_Projects \MR Projects \0627 WA South_Center R \CAD \ActiveCAD \0627r611.dgn TARGET EXISTING ALARM PANEL TO REMAIN. VERIFY EXISTING ALARM PANEL LOCATIONS REMS CONTROL WIRING PLAN DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS VERSION MR2010_08 °�1° CONFIGURATION LL 11-09-10 BP -3.O PERMIT SET DRAWN BY TLY CHECKED BY JA ARCHITECTS PROJECT NO. nameofpersonplotting 1U52010 NOT TO SCALE El 1)61-0-1S1 RECETVPD NOV 19 2010 PERMIT CENTER SCALE BAR: 16" = 1' -0" 1 11 III 1I111I1111111111fl1111 11111111111 0 4' 8' 12' 16' 20' 24' 28' 32' 36' 40' TARGET SPORE SOUTH CENTER WA STORE T0627 VERSION MR2010_08 °�1° CONFIGURATION LL TITLE REMS CONTROL WIRING PLAN & SCHEDULES 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 SHEET R611 ■ T -0627 SOUTH CENTER, WA • TO REMS -115 • SEE RE11� FVAP COIL R1I' 2 -I 22/4 1 IPRODUCE � LABELING 1 184 2 -1 22/4 i 0 2 -0 18/4 2 -0 18/4 2 -I 2 -I 22/8 REMS2 PRODUCE COOLER 183 EVAP COIL R1 MEAT COOLER 182 EVAP COIL D1 R1 22/4)(22/4 RLI SW /DA 2 -1 22/4 L J 0 a- w EVAP COIL D1 R1 D2 R2 2 -I 22/4 2 -1 22/4 22/4) 2 -1 2 -1 22/4 TO REMS -3 SEE R611 FREEZER 181 I Il II 1 I I I _V - I V i 1 i t II I I� III I i! 1 11 1 11! 1 II WALK -IN COOLER & FREEZER CONTROL WIRING PLAN GENERAL NOTES: REFRIGERATION SYMBOLS: RLN4 I RLN5Ii i i A. ALL REMS PANELS, CABLE AND COMPONENTS ARE FURNISHED BY REMS VENDOR. B. REMS -1 PANEL (EINSTEIN PANEL) IS LOCATED IN ROOM ***.NEW REMS -1 PANEL IS INSTALLED AND POWERED (120 VAC) BY ELECTRICAL CONTRACTOR. VERIFY EXACT LOCATION ON ELECTRICAL PLANS. SEE EMC DRAWINGS FOR CONNECTIONS TO REMS -1. C. REMS -2 IS LOCATED ON TOP OF WALK -IN COOLER /FREEZERS AND IS INSTALLED AND POWERED (120 VAC & 208 VAC) BY ELECTRICAL CONTRACTOR. D. REMS -3 AND REMS -4 PANELS ARE LOCATED ON TOP OF SALES FLOOR CASES AND ARE INSTALLED AND POWERED (120 VAC) BY ELECTRICAL CONTRACTOR. INSTALL PANELS SO THEY ARE HIDDEN FROM VIEW. SEE 1/R401. E. LOW VOLTAGE CABLE INSTALLED BY ELECTRICAL CONTRACTOR, TERMINATION CONNECTIONS BY REFRIGERATION CONTRACTOR. F. DIV 26 ELECTRICAL CONTRACTOR INSTALLS ALL REMS PANELS AND DOOR SWITCH AND ALARM PANELS. G. DIV 24 REFRIGERATION CONTRACTOR INSTALLS ALL SENSORS, LEAK TRANDUCERS AND LEAK INDICATORS WITH THE EXCEPTION OF CASE TEMPERATURE SENSORS WHICH ARE FACTORY INSTALLED BY THE CASE MANUFACTURER. H. FOR ADDITIONAL INFORMATION FOR THE INSTALLATION OF REMS COMPONENTS, SEE DETAILS ON R501, R511 AND R521. I. REMS DRAWINGS PROVIDED BY ENERGY MANAGEMENT CONSULTANTS. CONTACT TECH. SUPPORT 0 608- 822 -3550. REFRIGERATION CONTRACTOR TO REFER TO REMS DRAWINGS FOR FINAL CONNECTIONS. J. SEE DETAIL 6/R501 FOR EVAPORATOR ELECTRIC DEFROST TERMINATION (AO) H T 411) SYSTEM NUMBER GROCERY ZONE TEMP & HUMIDITY SENSOR DISCHARGE AIR TEMP. SENSOR RETURN AIR TEMP. SENSOR (MT TEMP CASES/ WALK -INS) DEFROST TEMP/DT CASES SENSOR (LOW TEMP /DT CASES & WALK -INS) REFRIG. TRANSDUCER SUCTION TEMP SENSOR (LOOP STORES ONLY) i (AOl) i T2 REMOTE PANEL AT WALK -IN COOLER /FREEZER REMOTE PANEL AT MARKET CASES REMOTE PANEL AT MARKET CASES LIGHT /DOOR HEATER CONTROL PANEL ALARM ANNUNCIATOR PANEL REMS CABLE NUMBER REMOTE CONDENSER/ COMPRESSOR UNITS ROOFTOP COMPRESSOR RACK ROOFTOP COMPRESSOR RACK CONDENSER UNIT ELECTRONIC EVAPORATOR PRESSURE REGULATING VALVE. REMS2 T1 REMS3 A 7 REMS4 R1 77 HEMS- I /DH D1 ; A -12 " 05M -8 ALARM 0 M -12 ® -Al: m SW /DA DOOR SWITCH & DOOR ALARM HORN & STROBE © RLI REFRIGERANT LEAK INDICATOR HORN /STROBE R 2 © T H ZONE TEMPERATURE AND HUMIDITY SENSOR R 1 AS llog► REMS1 EINSTEIN PANEL (B05) SENSOR DETAIL. REMS CABLE MARKER LEGEND: K. THE LIGHT /DOOR HEATER CONTROL PANEL, REMS -L /DH, CONTROLS THE DISPLAY LIGHTS FOR ALL CASES AND ANTI -SWEAT DOOR HEATERS FOR THE ICE CREAM AND DAIRY CASES. THE DUAL TEMPERATURE CASES COME FURNISHED WITH INTEGRAL DOOR AND FRAME ANTI -SWEAT HEATER CONTROLS LOCATED IN THE DOORS. L. THE POWER FOR THE FREEZER AND MEAT COOLER EVAPORATOR COIL FANS IS ROUTED THROUGH CONTACTORS IN THE REMS -2 PANEL. THE CONTACTOR CUTS POWER TO THE FANS WHEN THE WALK -IN IS IN DEFROST. INPUT (I) OUTUT (0) REMS PANEL NUMBER _ I 22/4 WIRE TYPE NOT TO SCALE 5 U a- w 5 U a- w R1 R2 2 -1 22/4 DAIRY COOLER 180 2 -1 22/4 SW /DA 2 -I 22/4 SW /DA 2 -1 2 -1 22/8 ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 J CTA ARCHITECTS ENGINEERS 219 2ND AVENUE SOUTH GREAT FALLS, MT 403.452.3321 406.454.1873 WWW.CTAGROUP.COM Y: \Target \Projects \MR Projects \0627 WA South_Center R \CAD \_ActiveCAD \0627r621.dgn TARGET REMS MARKET TEMP. AND HUMIDITY SENSOR. MOUNT ON COLUMN 96' AFF. MOUNT ON SAME COLUMN AS HVAC MARKET TEMP. AND HUMIDITY SENSOR. SEE DRAWING M111. TO REMS -2 SEE R611 — / 4 -I 2/4 118/4 fN1a SN1a RLN4 RLN4 I RLN4 I RLN5Ii i i T1 u D1 A 6 T 9[12 i (AOl) i T2 D (A06) I, T1 D1 A 7 !, I 77 i ' I — + B10 - 44 -1 2/4 eDa ■ 4 -0 18/4 14-1.- /4 'I 1 o-o rc it m 1 vm Elc I (A1305) vig I rc I .4 z I mm I I v I- ' II (aB04) II DATE ISSUED NOVEMBER 9TH, 2010 ISSUES AND REVISIONS (BO6) 11-09-10 BP-3.0 PERMIT SET (Bo?) ®R2 i Zt -WSO (B02) T -o DRAWN BY TLY R 3r I R1 R 1 cn (A601) .� Zt -1^60 I Zt -WSo ; A -12 " 05M -8 CHECKED BY 0 M -12 -Al: � T 1 R1 JA 12 R 2 (B05 ) T 1 R 1 ARCHITECTS PROJECT NO. R2 (B04 ) (B05) nameofpersonplotting 11/5•010 (22/4 4 -1 \- ?!I '�' (BO6) (606) Zl -WSO R2 (BOA) ®R1 ZI-WSO (Bo?) ®R2 i Zt -WSO (B02) T -o ®R1 8 -WSO R 3r I R1 R 1 cn (A601) .� Zt -1^60 I Zt -WSo ; A -12 " 05M -8 05M -12 0 M -12 -Al: � T 1 R1 12 R 2 (B05 ) T 1 R 1 804 T 2 R2 (B04 ) (B05) 2/4) REVIEWED FOR i CODE COMPLIANCE ADDRAVFD D:Y , 2010 City of Tukwila BUILDING DIVISION 2%4) al v - Ii (B09) i r 01 I co Nz m- -I1 v o STORE To627 VERSION MR2010 0$ °�'° 111tE MARKET & WALK-IN 301 STRANDER BLVD TUKWILA WA 98188 (sot) T 1 R 1 (B02) T T 2 (soz) T 3 R 3r 1 (BO3) T 1 R1 R 1 cn 8-1^490 Zt -riSO Zt -1^60 I Zt -WSo (B01) MARKET CONTROL WIRING PLAN NOT TO SCALE 1)6[0 -ISM' z 01 (B08) RECEIVED NOV 19 2010 PERMIT CENTER TARGET STORE SOUTH CENTER WA STORE To627 VERSION MR2010 0$ °�'° 111tE MARKET & WALK-IN 301 STRANDER BLVD TUKWILA WA 98188 PROJECT CODE 270627 CONFIGURATION LL CONTROL WIRING PLANS SHEET R621 T -0627 SOUTH CENTER, WA