Loading...
HomeMy WebLinkAboutPermit PG10-174 - PACIFIC COURT COMMUNITY BUILDINGPACIFIC COURT COMMUNITY BUILDING 4028 S 146 ST PG1O-174 City ATukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT Parcel No.: 0040000250 Address: 4028 S 146 ST TUKW Project Name: PACIFIC COURT COMMUNITY BUILDING Permit Number: Issue Date: Permit Expires On: PG10 -174 01/04/2011 07/03/2011 Owner: Name: HOUSING AUTH Address: 600 ANDOVER PARK W , TUKWILA WA 98188 Contact Person: Name: LARRY THOMAS Address: 9505 NE 84 CT , VANCOUVER WA 98662 Email: LARRY @THEGRINNELGROUPINC.COM Contractor: Name: UNLIMITED MECHANICAL INC Address: PO BOX 1457 , MARYSVILLE WA 98270 Contractor License No: UNLIMMI093M6 Phone: 360 367 -1753 Phone: 360 - 657 -2182 Expiration Date: 05/13/2012 DESCRIPTION OF WORK: PLUMBING FOR NEW SINGLE STORY 1454 SF COMMUNITY BUILDING WITH (2) BATHROOMS AND A SMALL KITCHEN FACILITY Value of Plumbing /Gas Piping: $8,500.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $242.81 International Fuel Gas Code Edition: 2009 Permit Center Authorized Signature: Date: U/ /G' `t' /// I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work.will- be-complie• with, whether specified herein or not. The grant g of this permit doe presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction on the back o this • - t. ormance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions Signature: Print Name: Date: 4 -2v3( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG10 -174 Printed: 01 -04 -2011 • • PERMIT CONDITIONS Permit No. PG 10 -174 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG10 -174 Printed: 01 -04 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. AAA • pttno --o (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 1L.1.11_gt King Co Assessor's Tax No.:S47c9-) Site Address: 4507U S 14041 --77--\(-"""∎ I ti•P• Suite Number: Floor: Tenant Name: ` New Tenant: ❑ Yes ..11-.".N..11-.".No Property Owners Name: ¥ Lb p - '■-'"l I`-J` 4"‘,Nte..... ( Mailing Address: CesM lr;3)- `....fh'-c-0.-- , \ t_is, t t \# 9,1Vv City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: L- Day Telephone ..C-07 Mailing Address: — 84'r7-1 "Ik G%8 692,z. City State Zip E -Mail Address:iOk t^I"r C' �'/ Y� /� �7 e iiCx r., SAL , C-J Fax Number: 7� (2,4C0 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 1 Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applicalions \Forms- Applications On Line \2010 Applications\ 7-2010 - Permit Application.doc Revised: 7- 2(111) bh Page 1 of 6 PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: /j`.i t LL.� Mailing Address: l4 j 7 Contact Person: \i6,,1�` -t \ i ' " S E -Mail Address:INFO.a) tr-d( Lo City State Zip Day Telephone: 1 tDZC Fax Number: �Z- Contractor Registration Number:13 t.I t 41-�1 1'b 1" 10 Expiration Date: a Valuation of Plumbing work (contractor's bid price): $ 8 Valuation of Gas Piping work (contractor's bid price): $ tD Scope of Work (please provide detailed information): tiZ�d' ��` f"` r lMn•51..) 1-,-, '-ya,3L.Liz,L 2 �1 r- �9- s? -v�MS {L � � {' S -1 Ott 1L t tip z `r\1 Building Use (per Intl Building Code): ce-ok_A- Occupancy (per lnt'l Building Code): fB' Utility Purveyor: Water: 1j1 Sewer:�W- L�- -L�`•1 ��1v Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain 1 Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks ( Urinals Water Closet Building sewer and each trailer park sewer r Rain water system — per drain (inside building) Water heater and /or vent 1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) , Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H: \ApplicationsWorms- Applications On Line \2011) Applications \7 -2010 - Permit Application.doc Revised: 7- 2010 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY PENALTY OF TIFY THAT 1 HAV RJURY B BUILDING OWNER OR AUT Signature: READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER AWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. ZEDA Pri ame: Mailin Date: _ /( —1 (-75 Day Telephoner 73— -3 \/fr V i V gegLoCvZ Date Application Accepted: 121Iu If City State Zip Date Application Expires: H:\Applications \Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh tle( Staff Initials: Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0040000250 Permit Number: PG 10 -174 Address: 4028 S 146 ST TUKW Status: PENDING Suite No: Applied Date: 12/16/2010 Applicant: PACIFIC COURT COMMUNITY BUILDING Issue Date: Receipt No.: R10 -02511 Initials: User ID: Payee: JEM 1165 Payment Amount: $242.81 Payment Date: 12/16/2010 11:56 AM Balance: $0.00 GREG GRINNELL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 075514 ACCOUNT ITEM LIST: Description 242.81 Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 48.56 000.322.103.00.00 194.25 Total: $242.81 doc: Receiot -06 Printed: 12 -16 -2010 INSPECHON NO. INSPECTION RECORD R etain a co with P- p ermit PERMIT NO. ', CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P�o,I'ect: 6 it_ ` 1' L ...... ---- Lry J i-/ Type of Inspection: JAL - P u /t2 %� r Address: 4O2ir i4 i44 sr- Date Called: Special Instructions: 6 S (3 3 2---zo t -r / Date Wanted: ( .m. -7 -- (5 --( p.m. Requester: Phone No: ? S3 — gF2,-7 St) c Approved per applicable codes. Corrections required prior to approval. COMMENTS: nP t t 7 „> dL. nL n P InspectC r: 0,4 fik--8 Date:-7 � ( S—(( n REINSP OICTE N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I 6300 Permit Inspection Request Line (206) 431 -2451 — ��,�INSPECTION RECORD Retain a copy with permit t /e' /7 ' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Southcenter Blvd., #100, Tukwila. WA 98188 (206) 439' -3670 Pro' t: ` 4C nrie Ir7"-- Type of Inspection: i7 Oil 4 - / Ai )04/01A Address: - 1/0.26 t.. /1/6 Date Called: ` Special Instructions: 0,1-462- 6 ! Date Wanted: p A -19 ri 4 a.:f` Requester: i (\,,, ie.___, t.,-. Phone No: -moo— 726 - * -- $tt-o Approved per applicable codes. Corrections required prior to approval. 54 ; COMMENTS: ` Crude n vu u A' p A -19 ri 4 ,,,) ,a,„ Lfe.,,,i-u i (\,,, ie.___, t.,-. $tt-o b r 1 A Inspectq Date: 1 — — +( n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. (r= INSPECTION RECORD Retain a copy with permit INSPECTION 0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ‘42' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 '3670 Project: P�0 %.f'.( &A .edT6�< t, • �3,,,/ Type of Inspection: /u -,e Address: �42g 3 O`L/.6 37 Date Called: O r f —r Special Instructions: ' Date Wanted: ® e. .5.---- / rn' Requester: Phone No: ...7a--772-6,32?... �- Approved per applicable codes. Corrections required prior to approval. COMMENTS: I rr ik — cu p I) Cdr u . . 1 o 1Q. ,- _ n A : rivl , (tit 11(>,p ` J , F .---5 ,. i I- .. (71-1;`,,-1 O r f —r ''',sr us e.-d , 1 A n -, Inspector: i� Date: g _I/ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 06 -01 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director LARRY THOMAS 9505 NE 84 CT VANCOUVER WA 98662 RE: Permit No. PG10 -174 4028 S 146 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/27/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. ■ In the event you do not call for an inspection and /or receive an extension prior to 07/27/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, dc)(.- -V—_,L Bill Rambo Permit Technician File: Permit File No. PG10 -174 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 HERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG10 -174 DATE: 12/16/10 PROJECT NAME: PACIFIC COURT COMMUNITY BUILDfNG SITE ADDRESS: 4028 S 146 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: `.� � CD Building 414, vision 22Vicr s \111 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 12/21/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 01/18/11 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page Page 1 of 1 General /Specialty Contractor A business registered as a construction contractor with LEti to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company UNLIMITED MECHANICAL INC 3606572182 Po Box 1457 Marysville WA 98270 Snohomish Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601329467 Active UNLIMMI093M6 Construction Contractor 7/26/1991 5/13/2012 Fire Protect System Unused iated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WWPLU "159MJ W W PLUMBING Construction Contractor Plumbing Unused 7/11 /1985 3/12/1987 Archived EMERACP150DL EMERALD CITY PLUMBING Construction Contractor Plumbing Unused 3/13/1985 3/12/1986 Archived Business Owner Information https: // fortress .wa.gov /lni/bbip /Print.aspx 01/03/2011 MECHANICAL LEGEND- CD RL - RS REFRIGERANT SUCTION PIPING SANITARY WASTE SANITARY VENT DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRCULATION DOMESTIC COLD WATER CONDENSATE DRAIN REFRIGERANT UQUID PIPING Cis - x) ELBOW, 90• ELBOW, 45• ELBOW, TIJRNING UP OR TOWARD ELBOW, TURNING DOWN OR AWAY BALL VALVE EXHAUST FAN MECHANICAL. EQUIPMENT CFM OA RA CROSSING LINES: NON--CONNECTING (TOP OR FRONT PIPE IS SHOWN AS soup LiNq BREAK IN PIPE (USE WHERE SECTION OF PIPING IS OMITTED FROM DRAWING FOR CLARITY) PLUMBING FIXTURE CALL-OUT EQUIPMENT CALL-OUT CUBIC FEET PER MINUTE OUTSIDE AIR RETURN AIR SA SUPPLY AIR WH WALL HYDRANT 001 GC EC MC THERMOSTAT CARBON DIOXIDE SENSOR GENERAL CONTRACTOR ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR GENERAL NOTES 1. DO NOT SCALE PLANS. FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION OF MECHANICAL sTbIEMS. 2. MECHANICAL DRAWINGS ARE DIAGRAMMATIC ONLY. ACTUAL SIZE AND LOCATION OF EQUIPMENT,. DUCTWORK AND PIPING MAY VARY DUE TO MANUFACTURER OR ACTUAL FIELD CONDMONS. rr SHALL BE THE CONTRACTOR S RESPONSIBILITY TO COORDINATE THE INSTALLATION OF MECHANICAL SYSTEMS WITH OTHER TRADES AND SYSTEMS SO AS TO PROVIDE ADEQUATE CLEARANCE AND ACCESSIBILITY AS REQUIRED BY MANUFACTURER'S RECOMMENDATIONS AND AS SHOWN ON PLANS. 3. ALL DUCTWORK SHALL BE SEALED PER IMC AND SMACNA. 4. CONCEAL ALL PIPING AND DUCTWORK INSIDE WALLS AND ABOVE CEILINGS UNLESS SHOWN OTHERWISE 5. REFER TO ARCHITECTURAL PLANS AND ELECTRICAL PLANS PRIOR TO INSTALLING MECHANICAL SYSTEMS TO VERIFY LOCATIONS OF OTHER BUILDING SYSTEMS. 6. REFER TO ARCHITECTURAL PLANS TO VERIFY ALL LOCATIONS OF NEW FIRE RATED ASSEMBLIES. ALL DUCT PENETRATIONS OF FIRE RATED ASSEMBUES SHALL BE PROTECTED BY FIRE DAMPERS. 7. FIRE SAFE ALL DUCT AND PIPE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. 8. G.C. SHALL PROVIDE PRELIMINARY REPORT AND COMPLETE SYSTEM COMMISSIONING PER WASHINGTON STATE ENERGY CODE SECTION 1416, AND THE COMMISSIONING GUIDEUNES, AS PUBLISHED BY THE BUILDING COMMISSIONING ASSOCIATION. 9. ALL DOMESTIC WATER PIPING SHALL BE INSULATED PER WASHINGTON STATE ENERGY CODE. FAN SCHEDULE MARK SERVICE LOCATION FAN DATA MOTOR DATA WHEEL TYPE WHEEL DIA(IN) BLADE TYPE CFM TOTAL S.P. IN W.G. DRIVE TYPE AMPS V. PH. MAX. SONES BASIS OF DESIGN NOTES' EF-1 TOILET CEILING CENT 6 BI 50 EF-2 RANGE HOOD KITCHEN CENT 7 BI 100 DIRECT DIRECT .2 120 .3 1.2 120 .9 EF-3 MEETING RM CEILING CENT BI 150 .1 DIRECT .5 120 1.4 BROAN QTXE050 BROAN QDE 30SS 1 2 BROAN QTXE150 3 NOTES: 1. SWITCH WITH UGHTS. 2. INTEGRAL FAN AND LIGHT SWITCH TO BE RE-WIRED TO WALL SWITCHES BY E.C. FOR ADA OPERATION. 3. PARALLEL CONTROL WITH WALL SWITCH AND CO2 DETECTION: GET8012 ELECTRIC HEATER SCHEDULE MARK EH -1 EH-2 SENS CAP (MBH) 41 4732 74 ELECTRICAL DATA KW STEPS VOLT PH BASIS OF DESIGN NOTES .42 1.4 1 1 240 240 KING KCV 2404 1 KING KCV 2415 1,2 EH-3 .3387 0.7 1 EH-4 3188 .94 1 240 240 KING KCV . 2407 1,2 1 KING KCV 2410 1,2 EH-5 716 .21 1 120 1 KING KCV 1202 1,2 NOTES: 1. PROVIDE WITH REMOTE LINE VOLTAGE THERMOSTAT TH110P 2. (2) OF THESE. FAN COIL UNIT SCHEDULE MARK FC -1 CFM 350 EXT. STATIC PRESS. (IN. W.G.) 0.00 DX COIL DATA (13410A) E.A.T SENS. TOTAL E.A.T 0.A DB/WB CAP. CAP. DB HEATING CFM (CLG) (MBH) (MBH) HTG. (MBH) 75/63 6.0 9.0 70 8.6 0 ELECT. DATA HP. V. PH. MCA (W) 0.02 240 0.4 CON FIG. WALL BASIS OF DESIGN EMI - WLHGO9D0 NOTES 1 NOTES: 1. EXTEND CONDENSATE DOWN INSIDE OF WALL TO 6" ABOVE GRADE. HEAT PUMP SCHEDULE -- AIR SOURCE - R41OA MARK. CONDENSER DATA CFM S.P (IN. W.G.) HP-1 600 0.0 E.A.T. E.A.T. DEG.F. DB/WS LG. (DEG.F.) C 80 21 80/67 TOOLING TOT. OAP. (MBH) 9.0 DATA SENS. CAP. (MBH) 6.0 ELEC. INPUT (KW) .7 HEATI E,kT. DB (DEG.F.) 70' NG DATA SENS. CAP. (MBH) 8.6 ELEC. INPUT (KW) ELECTRICAL DATA V. PH. RLA MCA MOCP SEER COP EQUIP SOUND DATA DB BASIS OF DESIGN NOTES .7 240 4.7 5.7 15 13 3.3 45 EMI - S1 HG9000D NOTES: 1. INSTALL ON GRADE NORTH OF BUILDING. PROVIDE WITH 10' UINE SET AND WALL MOUNTED PROGRAMMABLE THERMOSTAT. PLUMBING FIXTURE CONNECTION SCHEDULE UNIT NO. FIXTURE LOCAL CONNECTIONS CW. HW. WASTE VENT REMARKS NOTES P-1 WATER CLOSET 1/2 2 1.6 GPF TANK TYPE, ADA COMPLIANT P-2 LAVATORY 1/2 1/2 1-1 /4 1-1/4 ADA COMPLIANT P-3 FD KITCHEN SINK FLOOR DRAIN 1/2 TRAP PRIMER 1/2 1-1/2 1-1/2 2 1-1/2 ADA COMPLIANT JR SMITH 2005 - 2" WH WALL HYDRANT 1/2 WOODFORD B65 2 NOTES: i . PROVIDE WITH TRAP PRIMER CONNECTION 2. MOUNT ON NORTH WALL BESICE KITCHEN DOMESTIC WATER HEATER -- ELECTRIC MARK S SERVES L LOCATION K KW V VOLTAGE G GALLONS B BASIS OF DESIGN N NOTES WH -1 B BUILDING K KITCHENETTE 2 2.5 2 240/1 2 20 A A.O. SMITH EJCS-20 1 1,2 NOTES: 1. MOUNT UNDER KITCHEN COUNTER 2. PROVIDE WITH BLADDER TANK BT-1; AMTIROL. ST-5 MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULE MARK DESCRIPTION SERVES BASIS .OF DESIGN NOTES COS- 1 CARBON DIOXIDE SENSOR M EMT NG ROOM GE T8012 CP-1 HOT WATER RECIRCULATING PUMP DOMESTIC HOT WATER BELL AND GOSSETT NBF-8S/LW NOTES: 1. BRONZE WET ROTER CIRCULATOR. 100% LEAD FREE. 3 GPM CD 6 FT HEAD. 39 WATTS 0 120v 2. PROVIDE WITH AQ-1/2 AO UA.STAT. CONNECT AQUASTAT UPSTEAM OF PUMP ON COPPER RECIRCULATION PIPE. 1,2 SEPARATE PERMIT REQUIRED FOR: <Mechanical Electrical 0 Plumbing t"Gas Piping City of Tukwila lEiljPJ?ING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE': Revisions will require a new plan submittal and may include additional plan review fees. j FI Permit No. COPY Plan review approval is subject to errors and omissions. kpproval of construction documents does not authorize vio ed code or ordinance. Receipt of approv anct1.s acknowledged City Of Tukwila BUILDING DIVISION -REVIEWED FOR CODE COMPLIANCE APogNIVED DEC 28 2010 utf--- City of Tukwila BUILDING DIVISION CITYRMILA DEC 1 6 2010 PERMIT CENTER Aardvark Engineering Services 2940 WESTLAKE AVE., SUITE: 301 Seattle, Washington 98109 (206) 281-7379 fax (206) 352-7231 a) CO cis E 0 cr) :=7L- a) a) 92 cs) 0 u_ <- _c o 0 0 06 0 _c L.b) 0 c0 _J a) 75 :P- o 5 'E ED O • 0 o Architecture & Urban Design 204 First Avenue South, Seattle, Washington 98104 PHONE: (206) 624 7880 / FAX: (206) 622 1766 Ca 143; 40 ti) 0 Z P. ST ru US 10 DRAWING ISSUE BID SET: JULY 12,2010 DRAWING TITLE MECHANICAL LEGENC & SCHEDULES SCALE: 1/4" PLOT DATE: JULY 12 2010 CAD FILE: M-O.DWG PROJ. MGR.: RL DRAFTER: ELA SHEET NO I= 0 a) CO cis E 0 cr) :=7L- a) a) 92 cs) 0 u_ <- _c o 0 0 06 0 _c L.b) 0 c0 _J a) 75 :P- o 5 'E ED O • 0 o R-10 INSULATING BASE IE-ELECTRIC WATERWAY CONNECTORS SIGHT GLASS AQUA STAT .71/2"HWR - - —THERMOMETER NOTE: G.C. TO PROVIDE CLOSURE PANEL UNDER COUNTER SEISMIC BRACES EXTEND P&T TO F.D. ELECTRIC WATER HEATER-1 CONNECTION DIAGRAM NOT TO SCALE 1/4" LIQUID 1/2" SUCTION SIGHT GLASS R - 410A THERMOSTATIC HEAT PUMP EXPANSION VALVE 00(6, heal-ot ym)51--- he, a cuod UNDER. COUN 1— 1 /2'1VIR / O 1/2"V C r- 10 WALL CAP 0"X3— 1/4 PLAN NOTES: 0 INSTALL BOTH SHUT-OFF BALL VALVES BEHIND LOCKING STEEL ACCESS PANEL. MILCOR - 3601-014-4 OR EQUAL. 0 SPACE VENTILATED BY OPERABLE WINDOW. 0 SPACE VENTILATED BY EXHAUST FAN, ACTIVATED BY CO2 SENSOR. EXHAUST TO ROOF CAP 0 36"X1C" CONCRETE PAD BY G.C. (1) INSTALL LOCKING WALL HYDRANT. 0 UNDERCUT DOORS 3/4" FOR VENTILATION AIR FLOW. RL SCHRADER CHARGING VALVE - RS REFRIGERANT VALVE HEAT PUMP FILTER DRYER REFRIGERANT VALVE SCHRADER CHARGING VALVE REFRIGERANT PIPING DETAIL NOT TO SCALE NOTE: ALL REFRIGERATION PIPING SPECIALTIES SHOWN SHALL BE PROVIDED BY MECHANICAL CONTRACTOR. CONNECT TO EXISTING SAN SEWER 2 P-3 KITCHEN HWR UNDER SLAB INSULATE 2" 1/2" I-1W UNDER SLAB \ INSULATE M ETING OOM / OF IkE 75 SF /3" AIL COMMUNITY SPACE 620 SF 0 3/4" CW UNDER SLAB tri-1-7/ 1 1 1 1 1 WO EN 3/4"CD 0 RADE 1 4''RL. 1/2''RS 1 OFFICE I 220 SF 1 ------ -- 00 1. ,'MEETING ROOM 1 40 SF 4:411, o AT7 • P-2 HALL STORAGE ITCHEN BUIL SHUT SHU OF OFF • MEN G 0 11 r ()--(Tt) LEu -- / 4" --Jo 3/4"WATER FROM METER (SEE CIVIL) \ ,, \ 2 \ i1/4 "......,,,,i4N . / ----........,...\ 00 PACIFIC COURT COMMUNITY BUILDING FLOOR PLAN • 1,454 SF REVIEWED FOR CODE COMPUANCE APPROVED DEC 28 2010 City of Tukwila BUILDING mem AS$TUSILA uEC 1 6 2010 PERMIT CENTER Aardvark Engineering Services 2940 WESTLAKE AVE., SUITE: 301 Seattle, Washington 98109 (206) 281-7379 fax (206) 352-7231 Ioyi Urb. $v VAS '10 4•4.,*..n 03 •.., A `Z Ift J3 OIST ANAL 0 .1 10l 11T1 DRAWING ISSUE BID SET: JULY 12,2010 DRAWING TITLE MECHANICAL FLOOR PLAN SCALE: 1/4" =11-0" PLOT DATE: JULY 12 2010 CAD FILE: M-1.DWG PROJ. MGR.: RL DRAFTER: ELA SHEET NO M-1