Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG11-033 - KING COUNTY / METRO
KING COUNTY METRO 12000 EAST MARGINAL WY S PG1 1 -033 City oPI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 7340600421 Address: PLUMBING /GAS PIPING PERMIT 12000 EAST MARGINAL WY S TUKW Project Name: KING COUNTY METRO Permit Number: Issue Date: Permit Expires On: PG11 -033 03/11/2011 09/07/2011 Owner: Name: KING COUNTY Address: 500 K C ADMIN BLDG , SEATTLE WA 98104 Contact Person: Name: Address: Email: DAVID ARBOW 13508 NE 124 ST , KIRKLAND WA 98034 DAV IDA @LAKERID GEPLUMBING. C OM Contractor: Name: LAKERIDGE PLUMBING & MECH Address: 13508 NE 124 ST , KIRKLAND 98034 Contractor License No: LAKERPM099RK Phone: 425 - 827 -9262 Phone: 425 - 827 -9262 Expiration Date: 05/25/2012 DESCRIPTION OF WORK: TAP INTO GAS LINE AT BOILER ROOM AND RUN 320 FT OF PIPE TO SERVE THREE ROOF -TOP HEAT RECOVERY UNITS INDEPENDENTLY FROM OTHER SYSTEMS IN THE ORIGINAL GAS BRANCH. WILL TAP INTO THE 5 PSI LINE AT BOILER ROOM, ADD REGULATOR TO DROP TO 3 PSI, RUN 320 FT TO BRANCH SERVING UNITS, TIE INTO BRANCH. ADD REGULATOR AT EACH UNIT TO GO FROM 3 PSI TO 14" WC. RUN REGULATOR VENTS TO OUTSIDE OF BUILDING. Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: $5,000.00 $120.75 SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Uniform Plumbing Code Edition: International Fuel Gas Code Edition: Date: 2009 2009 it exa find this permit and know the same to be true and correct. All provisions of law and ordinances wit whether specified herein or not. The granting of this permit does not p construction or the performance of work. on the back of this permit. Signature: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions Print Name: C, V\, r . S Date: 'jt� /�-d�� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG 11 -033 Printed: 03 -11 -2011 • • PERMIT CONDITIONS Permit No. PG 11 -033 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 9: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 10: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG 11 -033 Printed: 03 -11 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wvvvv.ci.tukwila.wa.us • Plumbing/Gas Permit No. % l Ci 33 Project No. (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 12000E Marginal Way S Tenant Name: Metro Transit (Municipality of Metropolitan Seattle) Property Owners Name: King County Mailing Address: 120001 E Marginal Way S Y'- 16!o-&Q -k Suite Number: Floor: New Tenant: ❑ Yes .. No Tukwila WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: David Arbow Mailing Address: 13508 NE 124th St E -Mail Address: DavidA @Lakeridgeplumbing.com Day Telephone: Kirkland (425) 827 -9262 WA 98034 City State Fax Number: (425) 821 -8984 Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATION Company Name: Lakeridge Plumbing & Mechanical Inc. Mailing Address: 13508 NE 124th St Contact Person: E -Mail Address: David Arbow DavidA @Iakeridgeplumbing.com Contractor Registration Number: LAKERPM099RK Kirkland WA City State Day Telephone: (425) 827 -9262 Fax Number: (425) 821 -8984 98034 Zip Expiration Date: 05/25/2012 ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: State Contact Person: E -Mail Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Wood Harbinger Mailing Address: Bellevue WA State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip H:\Applications\Fonns- Applications On Linc\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc Revised: 7 -2010 bh Page 1 of 2 Valuation of Project (contractor's bid pri 9 $ 5000.00 Scope of Work (please provide detailed information): Tap into gas line at boiler room, and run 320' of pipe to serve three roof top heat recovery units independently from other systems in the original gas branch. Will tap into the 5psi line at boiler room, add regulator to drop to 3psi, run 320' to branch serving units, tie into branch. Add regulator at each unit to go from 3psi to 14 "wc. Run regulator vents to outside of building. Building Use (per lnt'I Building Code): Occupancy (per lnt'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system – per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 • gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets 3.ti PERMIT APPLICATION NOTES - Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: RU713O :�t4V AGENT: Print Name: ko l 1.) N t� tz(30 c.J Mailing Address: 13501 l 2y t'`^- /Date: 2 - z2 -- 1 Day Telephone: LI - $ 2.-1-9 2 b 2- .kirtKL.ANib WI 6M69TCY3 4 City State Zip Date Application Accepted: ) -> t Date Application Expires: (1 Staff Initials: H:\Applications \Forms - Applications On Linc\2010 Applications \7.2010 - Plumbing -Gas Piping Permit Application.doc Revised: 7 -2010 bh Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 7340600421 Permit Number: PG11 -033 Address: 12000 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 02/22/2011 Applicant: KING COUNTY METRO Issue Date: Receipt No.: R11 -00318 Initials: WER User ID: 1655 Payment Amount: $125.00 Payment Date: 02/22/2011 07:41 AM Balance: $0.00 Payee: LAKERIDGE PLUMBING & MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 25356 125.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PHOTOCOPIES /DUP SERVICES PLAN CHECK - NONRES 000.322.103.00.00 000.341.690 000.345.830 Total: $125.00 96.60 4.25 24.15 doc: Receipt -06 Printed: 02 -22 -2011 _..4&;2,........„-INSOECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 PG 1( -033 e Project: LA ..) itt CAI 0 Type of_l_nspectior: , _ iN 1 4 -VI AJA-A Covki T Address: :7 1 4- (---- Date Called: .......... Special Instructions: .0e...A A -- P6S A 00,- 11/) oej ilitn-- /...) tk OP Wanted Date Want ..-- a.m. .,. 2.-- f / p.m. Requester: 1 Phone No --2■010 rliq -41190 VIApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: . oej ilitn-- /...) tk OP 1 Pi . . • . • I -■ 1_ Ins pe, or: ( lk31 _ afQ AL ) Date• 42_ -- 0 R\E-1-NSPECTION FEE REQUIRED'. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • INSPECTION NO. CITY OF TUKWILA BUILDING D 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 :.. � .. 1. 'INSPECTION RECORD Retain a copy with permit PERMIT NO. (VISION (206) 431 -3670 Project /4/6 n �l1i //�f /�1�rD Type of InsRec // //l N 4.- 4s Address: /02. a 60 E ",-7,9,P/AA-9Z Date Called: • Special Instructions: Date Wa ted: g.-. l -- /l p.m. Requester: Phone No: D, — 7/ 1 — y/96 -.1;i. Approved per applicable codes. Corrections required prior to approval. COMMENTS: I r Iv,444 _ _ ^ _tom PECTION FEE REQUI ED. Prior toiext inspection. fee must be at 6300 Southcenter Blv ., Suite 100. Call to schedule reinspection. Date: A • PENETRATE METAL DRAFT CURTAIN AND CONNECT TO DISTING ROCF PEKTRATION REVISIONS Np changes shall be madeAto the sempaP E F 0 of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. I 0 0 e- 1 0-- e CURTAIN EXISTING vacuum 4" CONFIGURATION ROUTF_O .IN FRONT OF CURTAIN DETAIL SCALE: NOT TO SCALE tIB r..._... _ .—CCAUCC DRAM-CPO V LIEIIIITC11 TAIN TO BE UOUN1W AS SHOWN 7-1 =MI 0 0 0 0 GAS BOTTLE UNIT A$SEMBLY AND REBUILD 1 BODY SHOP DAYS IR-HRU-13A REMOTE CONTROL LOCATED 4.-6 HIGH, FR CM BOTTOM SECTION 0 AUX BOILER \.SEPARATE PERM REQUTED isettamcd 12 prawns CI Gin PIPS City ca Tukwila 13UILDII\16 DIVIS 3e x 18 22 22 x 113. CRIPPLED COACH PAINTIN PILE COPY SECTION SCALE: 1/r=I REVISION PNL PD PAIL PAINT STORE PAINT cLEAN UP Penult No., Plan review approval is subject to errors wd omissions. Approval of construction documents does not authorize the violation ot any adopted co:b or ordnance. :pi of . - is ackowledixd: $ NATURAL GAS PIPING AND ELECTRICAL PLAN SCALE: 1/16-=1.-0" PG I-- 033 1 —51-11t11. MbTLS ousrm4c. 2,••!.Gc... _CE 6NbJCE =.71:55560.oti:17-YL_L-P4V-sMIVek; Pki.E±Le:c alizt6...'"9.AL._.32.r".1311:1grbrwc:r__Ritishi.fe. Terrania 35r - - - • pi.PrmaL6.14id -ciff- AT F SIZE, IF N ONE INCH SCALE ACCORDINGLY DESIGNED: DRAVOI: .NSB CJ\KAI CHECAED: RECOMMENDED: Municipality of Metropolitan SeatUe APPROVED: cowman Na. T/M22-89 MAINTENANCE CENTER UNIT REPAIR VENTILATION MODIFICATION SECTIONS AND DETAILS F1LE NO: T30 DRAINING NO: A B /1-2:211 D E City Oflbkwila BUILDING DIVISION FEB 22 2011 PERMIT CENTER PLAN (E)4" FD —3/4 "D TERMINATE AT FD TAILPIPE EXHAUST SYSTEM FAN WITH LIGHT 3/4 "C r-T 28x74 DOWN HRU TO CORAYVAC ONTROL AN — POC SCALE: 1/8"=1'-0" r 1 R REVIEWED FOR - CODE COMPLIANCE APPRMED MAR 092011 City of Tukwila BUILDING DIVISION Dti WEGOLRTOCZ "T© 0'5 g & c \PE_. Ro1J \LENT TO c..- €R.‘06Z SHEET NOTES 0 GAS PRESSURE REGULATOR, REDUCE FROM 3 PSI INLET PRESSURE TO 14 IN. W.C. OUTLET PRESSURE; SIZE PER SCHEDULE; SENSUS OR EQUIVALENT OF MAXITROL. PROVIDE VENT PIPING; ROUTE TO EXTERIOR OF BUILDING. UNIT CAPACITY (KFH) MODEL SIZE SPRING ORIFICE VALVE ANGLE HRU -12A 750 143 -80 -2 1-1/4" GREEN 3/8" — 0' 4' 8' SCALE: 1/8" = 1' ECEIVED FEB 22 2011 peRmiT CNTER FIELD DIRECTIVE #10 / ■III MN WOOD HARBINGER Mechanical and Electrical Engineers JOB TITLE Metro Transit Div. — CSC Heat Recovery Unit Replacement C C Bellevue, WA SHEET TITLE L2 NORTHEAST —HVAC & PIPING PLAN CONTRACT NUMBER C00414C09 DRAWN BY • YGK SHEET NO. MSK -04 1/8" -1' -0" 1/21/11 to-5 Co W.1 EC_" - 9-12" &-) kr Tv ms 1� O ( 1, 2cot.113 Eel" LJ 1" v\ Ev J 1 12 C A S L14J E 28x74 DOWN FROM HRU -13A 14x12E . 60x28 28x30 REVIEWED FOR CODE COMPLIANCE. M D AVFD o 30x14S UP W/ TURNING VANES TRANSITION TO 20x12 UP TO HV -17 14x30E UP W/ TURNING VANES, TRANSITION TO 14x38E UP TO HV -17 46x16—/ L (E) ER • 56x36 -2200 EE \ 21x14E ER -1 22x10 835 CFM (TYP 3) 14x14E • SR20 -1500 (TYP 3) Q- ` -46x18 !VD 38x16 SCALE: 1/8"=1' —0" 0' 4' 8' • SCALE: 1/8" = 1' FIELD DIRECTIVE #10 JOB TIRE - WOOD HARBINGER Metro Transit Div. — CSC Heat Mechanical and Electrical Engineers Recovery Unit Replacement Bellevue, WA SHEET TITLE CONTRACT NUMBER DRAWN BY SHEET NO. L2 NORTHWEST —HVAC & PIPING PLAN 000414009 YGK MSK -05 M1.12 SCALE /8" =1' -0" �TE1/21/11 SHEET NOTES, g0 GAS PRESSURE REGULATOR, REDUCE FROM 3 PSI INLET PRESSURE TO 14 IN. W.C. OUTLET PRESSURE; SIZE PER SCHEDULE; SENSUS OR EQUIVALENT OF MAXITROL. PROVIDE VENT PIPING; ROUTE TO EXTERIOR OF BUILDING. UNIT CAPACITY (KFH) MODEL SIZE SPRING ORIFICE VALVE ANGLE HRU -13A HRU -25A 750 1000 143 -80 -2 243 -8 -2 1-1/4" 1-1/4" GREEN GREEN —BLACK 3/8" 1/2" — 10 DEG DISCONNECT 1-1/2" GAS FROM 2-1/2" GAS AND CAP. REMOVE 1-1/2" GAS TO INSTALL NEW PIPING AS SHOWN AS REQUIRED. 11 RELOCATE AND INSTALL EXISTING SHUT —OFF VALVE AS SHOWN. REVIEWED W MAR 0 9 2011 C' �YOfTU�18 � BUILDING •DIVISInly ECEWVED FEB 2 2 2011 CENTER FIELD DIRECTIVE #10 f — WOOD HARBINGER Mechanical and Electrical Engineers JOB TITLE Metro Transit Div. — CSC Heat Recovery Unit Replacement . Bellevue, WA SHEET TITLE L2 NORTHWEST —HVAC & PIPING PLAN M 1.12 CONTRACT NUMBER C0041 4C09 DRAWN BY YGK SHEET NO. MSK -06 1/8"=1'—o" MR 1/21/11 PENT COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG11 -033 DATE: 02 -22 -11 PROJECT NAME: KING COUNTY METRO SITE ADDRESS: 12000 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMEt/N d I' B i iniRilvision Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator n 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 02 -22 -11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03 -22 -11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name LAKERIDGE PLUMBING & MECH INC UBI No. 601349575 Phone 4258279262 Status Active Address 13508 Ne 124Th St License No. LAKERPM099RK Suite /Apt. License Type Construction Contractor City Kirkland Effective Date 12/12/1991 State WA Expiration Date 5/25/2012 Zip 98034 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LAKERPM1320PLAKERIDGE PLUMBING & MECH Construction Contractor General Unused 9/17/1987 11/23/1992 Archived MERCEIP132J8 MERCER ISLAND PLUMBING Construction Contractor General Unused 4/28/1987 11/23/1987 Archived MERCEIP164Q9 MERCER ISLAND PLUMBING & HTG Construction Contractor General Unused 11/29/1984 11/23/1987 Archived ISLANPH169L0 ISLAND PLUMBING & HEATING Construction Contractor General Unused 6/20/1984 6/18/1985 Archived EVERGPM066LA EVERGREEN PLUMBING & MECH INC Construction Contractor General Unused 6/1/1994 6/1/2006 Expired Business Owner Information Name Role Effective Date Expiration Date GLENNON, ANNE K Cancel Date 01/01/1980 Amount GLENNON, JOHN P Member 01/01/1980 6802690m475 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date CBIC SC7509 05/25/2002 Until Cancelled $12,000.00 04/30/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 14 Travelers Indemnity Company Th 6802690m475 05/25/2011 05/25/2012 $1,000,000.00 03/07/2011 13 PHOENIX INS CO 6802690M475 05/25/2010 05/25/2011 $1,000,000.0003 /03/2010 12 PHOENIX INS CO 6802690M475 05/25/2009 05/25/2010 $1,000,000.0003 /31/2009 11 PHOENIX INSURANCE COMPANY 6802690M475 05/25/2008 05/25/2009 $1,000,000.00 06/09/2008 10 ALLIED PROPERTY & CAS INS CO ACP752154878705/25/2004 05/25/2009 $1,000,000.0004 /10/2008 https://fortress.wa.gov/lni/bbip/Print.aspx 03/11/2011