HomeMy WebLinkAboutPermit PG11-061 - OUTBACK STEAKHOUSEOUTBACK STEAKHOUSE 16510 SOUTHCENTER PY PG1 1 -061 City 6kukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http:/lwww.ci.tukwila.wa.us PILUMBING /GAS PIPING PERMIT Parcel No.: 2623049127 Address: 16510 SOUTHCENTER PY TUKW Project Name: OUTBACK STEAKHOUSE Permit Number: PG11 -061 Issue Date: 04/14/2011 Permit Expires On: 10/11/2011 Owner: Name: SOUTHCENTER MOTEL HOTEL LTD Address: C/O POER MARVIN F & COMPANY , 500 108TH AVE NE #780 Contact Person: Name: JULIE CASKEY Address: 12601 132 AV NE , KIRKLAND WA 98034 Email: JULIEC @FASTWATERHEATER.COM Contractor: Name: FAST WATER HEATER COMPANY Address: 12601 132ND AVE NE , KIRIQLAND WA 98034 Contractor License No: FASTWWH948BC Phone: 425 636 -7084 Phone: (425)814 -3124 Expiration Date: 01/04/2012 DESCRIPTION OF WORK: REPLACE GAS WATER HEATER Value of Plumbing /Gas Piping: $8,399.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $47.25 International Fuel Gas Code Edition: 2009 Electrical Service Provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: tv I hereby certify that I have read and -xami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with, whether specified herein or not. The granting of this permit does not pre j e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc f wor,1. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: /(-7/--/7 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG 11 -061 Printed: 04 -14 -2011 1 • PERMIT CONDITIONS Permit No. PG 11 -061 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG 11 -061 Printed: 04 -14 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cLtukwila.wa.us Plumbing /Gas Permit No. PGAVG(Al Project No. (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCAT Site Address: 16510 SOUTHCENTER PKWY Tenant Name: OUTBACK STEAKHOUSE King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes Property Owners Name: OUTBACK STEAKHOUSE Mailing Address: 16510 SOUTHCENTER PKWY SEATAC City WA State ..No 98188 Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: JULIE CASKEY Mailing Address: 12601 132 AVE NE E -Mail Address: JULIEC @FASTWATERHEATER.COM Day Telephone: KIRKLAND City (425) 636 -7084 WA State Fax Number: (425) 636 -7085 98034 Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: FAST WATER HEATER 12601 132 AVE NE Contact Person: JULIE CASKEY E -Mail Address: JULIEC @FASTWATERHEATER.COM Contractor Registration Number: FASTWWH948BC KIRKLAND City WA State Day Telephone: (425) 636 -7084 Fax Number: (425) 636 -7085 Expiration Date: 01/04/2012 98034 Zip ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: State Contact Person: E -Mail Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD —All plans must be stamped by Engineer of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Applicalion.doc Revised: 7 -2010 bh Page 1 of 2 Valuation of Project (contractor's bid price): $ 8399 Scope of Work (please provide detailed information): REMOVE AND REPLACE GAS WATER HEATER IN COMMERICAL LOCATION Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty__ Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent 1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 . Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets PERMIT APPLICATION.NOTES1- Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: X1A,lPk Print Name: JULIE CASKEY Day Telephone: 425 - 636 -7084 Date: 4/8/11 Mailing Address: 12601 132 AVE NE KIRKLAND WA 98034 Zip 1 Date Application Accepted: 04 I `!4I I,' City State Date Application Expires: Staff Initial H :'Applications \Fortes- Applications On Line\2010 Applications \7 -2010- Plumbing -Gas Piping Permit Application.doc Revised: 7-2010 bh Page 2 of 2 0 0 C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049127 Permit Number: PG11 -061 Address: 16510 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 04/14/2011 Applicant: OUTBACK STEAKHOUSE Issue Date: Receipt No.: R11 -00716 Payment Amount: $47.25 Initials: JEM Payment Date: 04/14/2011 10:35 AM User ID: 1165 Balance: $0.00 Payee: FWH ACQUISITION COMPANY LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10922 47.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 47.25 Total: $47.25 doc: Receipt -06 Printed: 04 -14 -2011 • • ,.. INSPECTION NO. CITY•OF`.TUKWILA BUILDING DIVISION • 6300 Southcenter BIVd., #100, Tukwila. WA 98188 (206) 431 -3670 .Permit Inspectioh €tequest Line (206) 431 -2451 • INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: • • r• • ..atr,:aIO.1Z Type o( Inspection: 4-•ftA) A4 f(d Address: r • •I (0 t o S(- :P� Date Called: Speciai•Instructions: . „33 {.p 3 -o! • :. ��t'E�- 1Q 141v% Date Wanted a.m. Requester: Phone 1iO�' S 3' —1/ Q� • • • Approved 00, applicable codes. COMMENT& ElCorrections required prior to approval. - Pro 0014A irk //Ivey D/J R t SPECTION FEE R • UIRED. Prior o next inspection. fee must be d at 6306 SOuthcenter Blvd.. Suite 100. Call to schedule reinspection. S rt i • Form HLW -6 Manufacturer's Data Report for Water Heaters or Storage Tanks As Required by the Provisions of the ASME Code Rules 1 Manufactured and certified by: Rheem Manufacturing Co., Water Heater Division, 2600 Gunter Park Dr., East, Montgomery, AL 36109 (name and address of manufacturer) 2. Manufactured for: Not Known (name and address of purchaser) 3. Location of installation: Built for Stock (name and address) 4. Identification: 122296 - 122319 NA AS38422 122296 - 122319 2009 (mfr's serial no.) (CRN) (drawing no.) (National Board no.) (year built) 5 The chemical and physical properties of all parts meet the requirements of material specifications of the ASME BOILER AND PRESSURE VESSEL CODE. The design, construction, and workmanship conform to Part HLW, Section IV 2007 2008 None (year) /addenda (date)] (Code Case no.) 6. Shell: 1 SA414 GR. D .125" Glass 24 1/8 " ID 4' - 5 3/4" (no.) (mat'I spec., gr.) ]thickness (in.)] (lining) ]diameter (in.)] 7. Joints: Welded 85% [long (seamless, welded)] left. (compared to seamless)] [girth (seamless, welded)] (no. of shell courses) 8. Heads: Single Lap Fillet Weld [length (ft. & in., overall)) One Location Material Spec., Gr., Thickness Crown Radius Knuckle Radius Elliptical Ratio Hemispherical Radius Flat Diameter Side Pressure (Concave, Convex) Top SA4I4 Gr. D .232" N/A 1/4" N/A N/A 24 1/8" Flat Head Bottom SA285 Gr. C .3125" N/A 1/2" N/A N/A 23 5/8" Flat Head 9. Tubesheet: N/A Tubes: 24 (mat'I spec., gr.) 2 1/2" 3' - 9 1/16" SA178 - Gr. A 0.065" Welded (no.) [size (in.)] [length (ft. & in., overall)] (mat'I spec., gr.) ]thickness (in.)J (rolled or welded) 10. Nozzles, Inspection, and Safety Valve Openings: Purpose - (Inlet, Outlet, Drain, etc.) No. Diameter or Size Type How Attached Material Nominal Thickness Reinforcement Material Location Handhole up to 3" x 4" 1 3" x 4" N/A WELDED SA29 -1010 3/16" N/A Shell Inlet 2 1 1/2" NPT N/A WELDED SA29 - 1010 3/8" N/A Shell Outlet 2 1 1/2" NPT N/A WELDED SA29 -1010 3/8" N/A Shell Safety Relief VeIve 1 1" NPT N/A WELDED SA29 -1010 3/8" N/A Shell Drain 1 3/4" NPT N/A WELDED SA29 - 1010 1/4" N/A Shell Anode 4 3/4" NPT N/A WELDED SA29 -1010 1/4" N/A Top Head Thermostat 2 3/4 "NPT N/A WELDED SA29 -1010 1/4" N/A Shell Inlet 1 1 1/2" NPT N/A WELDED SA29 -1010 3/8" N/A Top Head Outlet 1 1 1/2" NPT N/A WELDED SA29 -1010 3/8" N/A Top Head 11. MAWP: 160 Max. input: 399,900 Btu /hr. Max. temp.: 210° Hydrostsatic test: 160 (psi) (Btu /hr or kW) ( °F) 12. Manufacturer's Partial Data Reports properly identifed and signed by Commissioned Inspectors have been furnished for the following items of this report: N/A (psi) (name of part, item no., Manufacturer's Name, identification stamps) 13. Remarks: Model 6400 -65 • • FORM HLW -6 (Back) CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this data report are correct and that all details of design, material, construction, and workmanship of this water heater or storage tank conform to Section IV of the ASME BOILER AND PRESSURE VESSEL CODE. "HLW" Certificate of Authorization no. 24,475 expiration date November 27, 2010 Date Name Rheem Mfg. Co., 2600 Gunter Park Dr., East, Montg., AL. 36109 Signed (manufacturer that constructed and certified water heater or storage tank) (by representative) CERTIFICATE OF SHOP INSPECTION Constructed by RHEEM MANUFACTURING CO. at 2600 GUNTER PARK DR., EAST, MONTG., AL 36109 I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and /or the state or province ofAlabama and employed by HSB CT of Hartford, Ct. 06102 - 5024 have inspected part referred to as data item 6, 7, 8, 9, & 10 and have examined Manufacturers' Partial Data Reports for items None and state that, to the best of my knowledge and belief, the manufacturer has constructed this water heater or storage tank in accordance with Section IV of the ASME BOILER AND PRESSUUR1 VESSEL CODE. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the water heater.or storage tank described in this Manufac rer's Data Report. F. ' hermore, neither the Inspector nor his employer shall beliable in any manner for any persona inj or property date or/ loss of any k' arising from or connected with this inspection. ut orize. Date nspector Commissions 1 at nc . en • orsements state, province, an no. 09 -01 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JULIE CASKEY 12601 132 AV NE KIRKLAND WA 98034 RE: Permit No. PG11 -061 16510 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/11/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/11/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ?o.it4)L Bill Rambo Permit Technician File: Permit File No. PG11 -061 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Contractors or Tradespeople Per Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name FAST WATER HEATER COMPANY UBI No. 602564544 Phone 4258143124 Status Active Address 12601 132Nd Ave Ne License No. FASTWWH948BC Suite /Apt. License Type Construction Contractor City Kirkland Effective Date 1/3/2006 State WA Expiration Date 1/4/2012 Zip 98034 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company FWH ACQUISITION COMPANY LLC Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FASTWHC110MC FAST WATER HEATER CO Construction Contractor General Unused 7/3/1989 6/19/1995 Archived FASTWHC052DF FAST WATER HEATER COMPANY Construction Contractor General Unused 3/6/1995 2/16/2007 Expired Business Owner Information Name Role Effective Date Expiration Date JORDAN, JEFF Partner /Member 01/03/2006 Bond Amount HANLEYBROWN, JASON Partner /Member 01/03/2006 549792C Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO 549792C 01/01/2005 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 PHOENIX CO0658M42A 02/17/201002/17 /2012 $1,000,000.0001 /05/2010 INS CO https://fortress.wa.gov/lni/bbip/Print. aspx 04/14/2011