HomeMy WebLinkAboutPermit PG11-095 - VULCAN EMPEMP
3314 S 116 ST
PG1 1 -095
City o+6 Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 1023049011
Address: 3314 S 116 ST TUKW
Project Name: EMP
PLUMBING /GAS PIPING PERMIT
Permit Number: PG11 -095
Issue Date: 07/14/2011
Permit Expires On: 01/10/2012
Owner:
Name: APOLLO HOLDINGS LLC
Address: 505 5TH AVE S #900 , SEATTLE WA 98104
Contact Person:
Name: KRISTINA GEILER
Address: PO BOX 1136 , MONROE WA 98272
Email: kgeiler @americanmechanical.com
Contractor:
Name: AMERICAN MECHANICAL CORP
Address: PO BOX 1136 , MONROE WA 98272 -4136
Contractor License No: AMERIMC071BH
Phone: 206 467 -6407
Phone: (206)467 -6407
Expiration Date: 01/10/2013
DESCRIPTION OF WORK:
GAS PIPING TO (2) UNIT HEATERS
Value of Plumbing /Gas Piping: $3,675.00 Uniform Plumbing Code Edition: 2009
Fees Collected: $120.75 International Fuel Gas Code Edition: 2009
Electrical Service Provided by:
Permit Center Authorized Signature:
Date: `7-11/ 4 -G/
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions
on the back of this pe
Signature:
Print Name: c,,G/ 0 1
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -4/10
PG11 -095 Printed: 07 -14 -2011
PERMIT CONDITIONS
Permit No. PG 11 -095
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: UPC -4/10
PG11 -095 Printed: 07 -14 -2011
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.uov
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No
Public Works PermitNo.
Project No.
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address`
Tenant Name:h\C?
Property Owners Name:
Mailing Address:
King Co Assessor's Tax No. \KY�U.0 \ \
Suite Number: Floor: \I-5
New Tenant: ❑ Yes ;,,No
City
State
Zip
CONTACT PERSON
ho do w
contact w
your permit is ready to b
Name:
Mailing Address:
Day Telephone:
City
State
Zip
E -Mail Address: Fax Number:
GENERAL CONTRACTOR INFORMATION --
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
AIL .111
Company Name-
Mai ling Address:
Contact Person:' 5�
L) �' t—< Gt■
E -Mail Addres). \: • gb %210L
Contractor Registration Number:
I \Q/1
City
V Day Telephone.
A ■ •
i
1641
piration at
ber:
41,
- tate
z
p
•
ARCHITECT OF RE
ORD — All plans must be stamped by Architect
of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be stamped by Engineer of R
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H: \Applications\Porms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 1 of 6
PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 - 3670
PLUMBING D GAS PIPING CONTRACTOR INFOR ATION�^
C
c),‘
ompany Name: \A� \c Ac_
Mailing Address: .Co - O \\-\,,S) \\' `n\c\N \N\
City - State Zip
Contact Person:
E -Mail Addre
1 i
Arty % 1\. ' .� r�l. 1 ' Js,.■ 41
Contractor Registratn Number: Expiration Date: 4\
Day Teleph
•n,.
C5L \2,
Valuation of Plumbing work (contractor's bid price): $
Valuation of Gas Piping work (contractor's bid price): $���
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'1 Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below:
Fixture Type;
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
(-)
H:\ Applications \Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application doe
Revised: 7 -2010
bh
Page 5 of 6
IDate Application Accepted:
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY 0 PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILD O E. I 'U r D e�NT:
iii
Signature. AMINO1MM Date: v �k
Print Name:
Mailing Address:
J
90.E
Day Telephone.
LOA& .111 •_
1
\`
CI
State
Zip
oltoRIlt■
Date Application Expires:
Staff Initials:
H: \Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 6 of
• 1
�J��I�4 wq� City of Tukwila
C a �J �
�s � z
1 908
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.Qov
Parcel No.: 1023049011
Address: 3314 S 116 ST TUKW
Suite No:
Applicant: EMP
RECEIPT
Permit Number: PG11 -095
Status: PENDING
Applied Date: 07/08/2011
Issue Date:
Receipt No.: R11 -01407
Payment Amount: $120.75
Initials: JEM Payment Date: 07/08/2011 03:29 PM
User ID: 1165 Balance: $0.00
Payee: JEFF REINDEL, AMERICAN MECHANICAL
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 008362
ACCOUNT ITEM LIST:
Description
120.75
Account Code Current Pmts
GAS - NONRES
PLAN CHECK - NONRES
000.322.103.00.00 96.60
000.345.830 24.15
Total: $120.75
doc: Receiot -06 Printed: 07 -08 -2011
INSPECTION RECORD,
Retain a copy with permit,
P6 I 01
INSPECTION NO. r - ..,PERMIT N0. •
CITY OF TUKWILA BUILDING: DIVISION �=
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - 3670`
Permit Inspection Request Line (206) 431-2451 •
Project:
ge.
Type Inspection: :
Address:
7_x+
Sr.
Date Called:
4
Special Instructions:
Date Wanted:. - '
' 41 r.
p.m.
Requester:
Phone Norr•
,qt:
Approved per applicable codes. DCorrections required prior to approval
COMMENTS:
•
•
•:
n REINSPECTION FEE REQ IRED. Prior to next inspection; fee inust'be - •
paid at 6300 Southcente�lvd., Suite 100. Call to schedule,reinspectioh.
- : • ,,�
INSPECTION RECORD P�rc
Retain a copy with permit I
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 E. (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451 .
Project:
Typp-gf Inspect'on: _s____,4 6
Address: '17,\ sr
3314 I((0
Date Called:
Special Instructions:
t �V
P` /0A-4-7 fr- ���� , Tt n
U A- , r /�� K.�C�
Date Wanted• // a.m.
���5!!, p.m.
Requester:
•
Phone No:
, C, -356 -6-o 81
Iic.: = codes. Corrections required prior to approval.
•
COMMENTS: A '
p*T` , ' A7Dr
r sr ki
7_) ,S, -
5%.---a-F ,ct I _.s.,)?p,)/ -r-'
I
AlQFd Il) ,i*sDe.4T.
l,(e...ir &A C.f 4' 1 a L F -
lnspe tor:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
Date:� -7
/ _ __• lil_
. •
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
•
1
1
PROJECT LOCATION
3314 SOUTH 116TH STREET
TUKWILA, WA
PROJECT DESCRIPTION
TWO 5 -TON LIEBERT UNITS WITH LEAD /LAG
CONTROL, SPLIT SYSTEM HEAT PUMP, TWO
UNIT HEATERS AND VENT FAN,
COMMISSIONING AND BALANCING PER PLAN.
MECH. CONTRACTOR
EMERALD AIRE, INC.
5108 D STREET NW
AUBURN, WA 98001
PROJECT MANAGER
V ❑ICE: (253) 872 -5665
FAX (253) 872 -5797
GENERAL CONTRACTOR
WILCOX CONSTRUCTION
234 5TH AVE S
EDM❑NDS, WA 98020
CONTACT PAUL CARTER
V ❑ICE: (425) 774 -4185
FAX: (425) 774 -4187
W. S. E. C. NOTES
THERMOSTATS SHALL BE INTERLOCKED
TO PREVENT SIMULTANEOUS
HEATING AND COOLING PER WSEC 1422.
GENERAL CONTRACTOR TO PROVIDE
ACCESS TO FIRE AND /OR
COMBINATION FIRE /SMOKE DAMPERS.
INSULATE REFRIGERANT PIPING PER
SEC, TABLE 14 -6.
SEAL DUCTWORK PER SEC 1414.1
INSULATE DUCTWORK PER SEC'TABLE
14 -5.
COMMISSIONING PER SEC SECTION
1416. 1. 1 SIMPLE SYSTEMS
Perm
EV
P
TEVPORARY VAULT
VICINTY MAP
PIa ; review ap F m { '.. .:. .. f0 e 't Pfbn2"1 "VTE°
ii�� and m,'6
pprovaI of construction documents does not autt izS
1h v :ofation of any adopted code or ordnance. Rec, .pt
of approved Fief y and conditions is ackn f { d
■
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
j�B oiletg :
By , / ///� � / JL am v
City Of Tukwila
SEQUENCE OF OPERATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 12 2011
City o kwila
BUILDIN'. ' +IVISICM
DRAWING KEY
THE VAULT IS SERVED BY (2) LIEBERT SPLIT SYSTEMS AH -1, AH -2
1. TEMPERATURE AND HUMIDITY CONTROL FOR AH -1 AND AH -2 IS
PERFORMED VIA THE FACTORY MOUNTED CONTROLS. THE UNITS HAVE BOTH
HUMIDIFICATION AND DEHUMIDIFICATION CAPABILITIES. THE UNIT
SETPOINTS ARE AS FOLLOWS:
- SPACE TEMP 70F (ADJ)
- HUMIDITY 50% (ADJ)
2. LEAD /LAG /BACKUP CONTROL:
- AH -1 AND AH -2 ARE CONTROLLED BY A LIEBERT CONTROL PANEL.
UPON DETECTION OF A LEAD UNIT FAILURE THE LAG UNIT IS
AUTOMATICALLY TURNED ON. THE LEAD UNIT IS ROTATED EVERY 7 DAYS
TO EQUALIZE RUNTIME, OR A DURATION SPECIFIED BY LIEBERT.
- MOTORIZED DAMPERS ARE CYCLED ACCORDINGLY TO LEAD LAG
CONTROL
- ECONOMIZER CONTROL SHALL BE THROUGH SEIMENS CONTROL LOGIC
3. AH -1 & AH -2 ARE TO BE MONITORED BY THE BAS VIA A MODBUS
COMMUNICATION CARD. THE FOLLOWING ALARMS WILL NOTIFY THE
OPERATOR:
- AH -1 AND AH -2 COMMUNICATION LOSS FOR 3 MINUTES.
- SPACE TEMP (VIA SIEMENS SENSOR): HIGH = 74F LOW = 66F
-SPACE HUMIDITY (VIA SIEMENS SENSORS): HIGH = 60% LOW = 40%
5 GRD IDENTIFIER
ii
SIDE WALL GRILL
SUPPLY GRILLE
THERMAFUSER
RETURN AIR GRILLE
EXHAUST GRILLE
EXHAUST FAN
EQUIPMENT TAG
T -STAT
L/V WIRE
DUCT RUN
ELBOW
REDUCER
SIDE TAPS
90 ELBOW
W/ TURNING VANES
FLEXIBLE DUCT
MANUAL DAMPER
FIRE DAMPER
SMOKE DAMPER
SMOKE /FIRE DAMPER
MOTORIZED DAMPER
BACKDRAFT DAMPER
VARIABLE VOLUME /TEMPETURE
VARIABLE FREQUENCY DRIVE
ELECTRIC
TAG
SPLIT SYSTEM
MANUF.
UNITS - INDOOR
MODEL
AREA SERVED
HEATING
SOURCE MBH /(KW)
COOLING
TONS MBH
CFM @S. P. MIN OSA
ELECTRICAL
VOLTS PH FLA WSA(NCA) OPD
WT
CONTRL
`
REMARKS.
AH -1
AH -2
FC -1
LIEBERT
LIEBERT
MITSUBISHI
MMD6OE
MMD6OE
PEAD -A30AA
VAULT
VAULT
INTAKE
ELEC (16. 5)
ELEC (16.5)
HP 32
5 61. 2
5 61. 2
2. 5 30
2500@.5 400
2500@.5 400
740@ .4 150
460 3 26 32. 5 35
460 3 26 32. 5 35
208 1 2.73 (2.7) N/A
498
498
73
7DAY
PWR FROM HP -1 UNIT BY EC
NOTES: CONDENSATE REMOVAL REQUIRED ON ALL UNITS, BY PLUMBER .
OUTDOOR UNITS
TAG MFR, MODEL TONS SEER VOLTS PH FLA WSA(MCA) ODP WT. UNITS SERVED REMARKS
`
SEPARATE PERMIT
�(�Q:
FOR:
H. P.
CU -1
CU -2
HP -1
.
LIEBERT
LIEBERT
MITSUBISHI
PFHO67A -H
PFH067A -H
PUZ- A3ONHA4
5
5
2.5
N/A
N/A
15.5
460
460
208
3
3
1
11. 7
11.7
--
14, 2
14.2
(25)
20
20
40
351
351
185
AH -1
AH -1
FC -1
NO ECONOMIZER PER WSEC 1433 EXCEPTION 1.
r1 WV RW
REQUIRED
Machanical
0 .•... .
.
EXHAUST FANS
0 Gas POMO
ELECTRICAL
TAG
MANUF.
MODEL
AREA SERVED
CFM @ S. P.
H. P.
RPM
VOLTS PH
MCA
WT.
dBA
CONTROL
REMARKS
EF -1
COOK
70CIOBH
CRATE STORAGE
100 @ 0.1'
1/25
1050
120 1
--
15
2.1SNS
CONT
FAN TO RUN CONTINUOUS
Tukwila
,BUILDING DIVISIO'd
RtUtIV
CITY OF TUKWILA
UNIT HEATERS
TAG MANUF.
MODEL
AREA SERVED
CFM
HEATING ELECTRICAL
SOURCE MBH AFUE VOLTS PH FLA
WT. CONTROL
UH -1
UH -2
REZNOR
REZNOR
UDAP -30
UDAP -30
INTAKE
CRATE STORAGE
456
456
NAT GAS 30 827.
NAT GAS 30 82X
120 1 1. 9
120 1 1. 9
115
115
FREEZE STAT
FREEZE STAT
JUL 08 2011
REMARKS TE
BVENT THROUGH ROOF VERIFY SIZE (24V CONTRO ?ER
BVENT THROUGH ROOF VERIFY SIZE (24V CONTROL)
C: \Users\grant?&11O
ts \Jobs \EMP Vault \2011 -02 -24 Vulcan DIP Vault Prelim Pa, mIt \CXR- HDE.drg
R
O
0
0
a
IPLOT DATE 3/15/20 1 l
Q
01E013110EVELOMMIT
oa.nD1D
▪ M DART
1-
Luz
U
Li
TITLE SHEET
SCAI.E. 1/4• - 1'-0'
MO
AHII
— —
AH-2
▪ 13; fi ir, I fi \1"- . r \‘• IWF7,712,T,HIR
77`` u7;
EE. PLANSL
; FOR DUCT
SIZING
••
•'
•
I
•
I' ii•
1 1 1.
I
EXPOED SPIRAL
1,11 DUCTWORK
I: !
!-
In
/ I i
°DUCT ELEVATION
• 2-0.
26(20 DUCT
ECONOMIZER
! DAMPERS
20X20 DUCT ;
— - --- \s_
OSA INTAKE HOOD
CURB LEVELING
ROOFING BY OTHERS
20X20 DUCT EC
W2' LINER . _
toein, A
FOR LEAD LAG SWTICHING
L1F
20X20 SOF
RETURN GRILLE
)
I/4. INTAKE HOOD/ECONOMIZER DETAIL
(
•
RELIEF HOOD
CURB LEVELING
ROOFING BY OTHERS
MODULATE W/ •
ECONOMIZER OPERATION
-- • -----
M1101611..
26(20 50F
- RETURN GRILLE
i -
. . .
.••• : -
1 1 .
•
. : .-•
: . •
I I :
•
. . •
. . .
C)!At. • r -o.
ELIEF HOOD DETAIL
7r7.4N! 7
,F 20X20 ni
00 TO RI
INTAKE H.
T
F
DQE66:111111.
)V JIM
)jIBW
tl • IIMMEZECMMI
itzr 20xI8
v/-
1
20X20 DUCT
UP TO
BOORS
DUCT DOWN THROUGH RELIEF HOOD
VAULT LID
1:1 il)p
VA
EXPOSED SPIRAL
f:OC.M. DUCTWORK
1<0.■"179 VAP-
::IVILAR A.P1:(1•TLE
, k
. .
•
• .
. \
a SCREENED
'DUCT UP
TO EF-1
r:RATF
INTER
MOTORIZED DAMPER
W/OCCUPANCY SE
POWER B
8'
THROUGH
Ir‘
CK
EN
OR
EC
UP
OF
VA/
/
17t
UP THROUGH ROOF
4' BVENT UP
THROUGH ROOF
A
PC
PC
1
1
41■
cijj
TMR
12'0
FC M
(TYP 2)
--CC:117
5
-!;(•:vy. PN, S AS
I 5 I
ri]
•
7
•
I -
-REVE
CODE COMPLIANCE
APPROVED
JUL 1 2 2011
,City of Tiikwila
[BOLDING DIVISION
111
OPENINGIPEplED •
‘-j csrjot,r/
01 1.„0 A- -
F., • r
(a9 '
/ I I
--62n
:I IL
CYlVin • 1.-0.
AIN LEVEL HVAC PLAN
CAIVAIERVILA
JIB_ 052011
PERMIT CENTER
2
a
!PLOT OA1E 3/13/20 1
cemaa.revEuranar
• COORDINATION
3.9.11
perturr
Dco
D
As emu
IX
<
0
o
rt
0-
uJ
2
EMERALD AIRE. INC.
C: \Mem grantrn Documenta\Joba \EMP Vault \ 2011-02-24 Vulcan EMP Vault Prelim Permit\ C3P—HDE.dag
FLOOR PLAN
SCALE: AS NOTED
M 1
. (
INTAKE HOCID
;;;;■.:N AN 7
RELIEF HOOD
•
UNITS ON SLEEPERS
BY GC
,
El I . •
. .
. .
. .
. .
. •
. .
. .
. .
. .
. .
. .
. .
. .
. •
. •
. .
. .
•
. .
. .
. .
. .
. .
. .
. .
. .
: .
• :
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 12 2011
City of Tukwila
BUILDING DIVISION
80 INTAKE
MAINTAIN 10FT FR
OM
EXHAUST
4' BVENT
N
UNIT ON SLEEPERS
BY GC
)
A:tf.:D - -•-•::•.-i- \---:;
RECEIVEI)
CITY OF TUKWILA
JUL 0 8 2011
PERMIT CENTER
1;
5
a
;PLOT DAM 3/0/20 1
oosion....00ntlomoter
11:1 A9 BUILT
C: \Users \ grontm ClocuMento \Jobs \BAP Voult \ 2011-02-24 Vulcan DAP Vault Prelim Permit \CXR—HOE.durg
ROOF PLAN
SCALE: 1/8 -
M2
'PERMIT COORD COPS
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG11 -095
PROJECT NAME: EMP
DATE: 07/08/11
SITE ADDRESS: 3314 S 116 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEP RTMENTS:jj.11
u I ing Division
ll�l
Public Works
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete IA
Comments:
Incomplete
DUE DATE: 07/12/11
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 08/09/11
Approved ri Approved with Conditions NI Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople liter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name AMERICAN MECHANICAL CORP UBI No. 601433818
Phone 2064676407 Status Active
Address Po Box 1136 License No. AMERIMC071BH
Suite /Apt. License Type Construction Contractor
City Monroe Effective Date 1/8/1993
State WA Expiration Date 1/10/2013
Zip 982724136 Suspend Date
County Snohomish Specialty 1 Plumbing
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
KING, KELLY EDWARD
President
12/07/2010
Amount
KING, CHERI L
President
01/08/1993
12/07/2010
KING, KELLY EDWARD
Treasurer
01/08/1993
12/07/2010
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
OLD REPUBLIC
SURETY CO
YLI230431
01/08/2002
Until Cancelled
$6,000.00
10/11/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
13
Continental
Western Ins Co
CWP2660790
01/08/2009
01/08/2012
$1,000,000.00
12/14/2010
12
0010 CAS INS
BH053278338
01/08/2006
01/08/2009
$1,000,000.00
03/10/2006
11
FEDERATED
SERVICE INS CO
9800988
01/08/2006
01/08/2007
$1,000,000.0002
/21 /2006
10
FEDERATED
SERVICE INS CO
367264
01/08/2006
01/08/2007
$1,000,000.0001
/06/2006
9
HARTFORD
CASUALTY INS
52SBAPP9651
01/08/2005
01/08/2006
$1,000,000.00
12/15/2004
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: / /fortress.wa. gov /lni/bbip/Print.aspx
07/14/2011