MECHANICAL PERMIT
Permit Number: M10 -008
Issue Date: 01/29/2010
Permit Expires On: 07/28/2010
Tenant:
Name: BAY VALVE SERVICES
Address: 4385 S 133 ST , TUKWILA WA
Owner:
Name: SEBCO INC
Address: 4020 E MADISON ST #320 , SEATTLE WA
Contact Person:
Name: KELVIN BATTLE
Address: 25500 74 AV S , KENT WA
Contractor:
Name: PERFORMANCE HEATING
Address: 7649 S 180 ST , KENT WA
Contractor License No: PERFOHA15ORT
Phone:
Phone: 425 251 -0356
Phone: 425 251 -0356
Expiration Date: 04/30/2011
DESCRIPTION OF WORK:
ADD (1) NEW ROOF TOP UNIT AND AIR DISTRIBUTION
Value of Mechanical: $19,000.00
Type of Fire Protection:
Fees Collected: $411.81
International Mechanical Code Edition: 2006
EOUIPMENT TYPE AND QUANTITY
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat /Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment0
* *continued on next page **
doc: IMC -10/06
M10-008
Printed: 01 -29 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: M10 -008
Issue Date: 01/29/2010
Permit Expires On: 07/28/2010
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Date: 01 I'M
exa ned this permit and know the same to be true and correct. All provisions of law and ordinances
wit , whether specified herein or not.
The granting of this permit does not pre . e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit.
Signature: �� �/ �� Date: j�i
Print Name: /■■+ Ee"-//
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -10/06
M10-008 Printed: 01 -29 -2010
Parcel No.: 2613200133
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
4385 S 133 ST TUICW
BAY VALVE SERVICES
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M10-008
ISSUED
01/22/2010
01/29/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of arty construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: Readily accessible access to roof mounted equipment is required.
5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread
index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed
spaces in buildings of Type ID, IV, or V construction, the flame spread and smoke - developed limitations do not apply
to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or
floor finish.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
doc: Cond -10/06
M10-008 Printed: 01 -29 -2010
• 44
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name: /,/ ✓! �'i�/�
Date: /�'/ 'd
doc: Cond -10/06
M10-008 Printed: 01 -29 -2010
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
ht�p: "tr. \rtr.ci. tuktri/a. ira. us
Building Permit No.
Mechanical Permit No.
Plumbing /Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 4385 S. 133rd St
Tenant Name:
Bay Valve Services
Property Owners Name: Sebco Inc
Mailing Address: 4020 Madison ste #320
King Co Assessor's Tax No.: 2613200133
S uite Number: Floor: 1st
New Tenant: ❑ Yes ..No
Seattle
City
Wa
State
98112
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Nance: Kelvin Battle D ay Telephone: 425 -251 -0356
Mailing Address:25500 74th Ave S
E-Mail Address: kelvin @pmghvac.com
Kent,
City
WA
State
Fax Number:253- 867 -5775
98032
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: Performance Heating & Air Conditioning
Mailing Address: 25500 74th Ave S
Kent,
City
Contact Person: Kelvin Battle D ay Telephone: 425 -251 -0356
Fax Number: 253-867-5775
WA
State
E -Mail Address: kelvin @pmghvac.com
Contractor Registration Number: PERFOHA15ORT
Exp
98032
Zip
iration Date: 4/ 30/10
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
City
Contact Person: D ay Telephone:
E -Mail Address: Fax Number:
State
Zip
ENGINEER OF RECORD — Alt plans must be wet stamped by Engineer of Record
Company Name: I BTL
Mailing Address: 17924 140th Ave NE Suite 220
Woodinville
Wa
98072
City,
State
Contact Person: Eric Dann D ay Telephone: 425.814.8448
E -Mail Address: Eric.Dann@btleng.net
Q \Apphcauons \Fors- Applications On Line \3 -2006 - Permit Application.doc
Re, Ised: 7.2111(
bh
Fax Number:
Zip
Page I of 6
MECHANICAL PERMIT INFORMATION — 206 - 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: Performance Heating and Air Conditioning
Mailing Address: 25500 74th Ave S
Contact Person: Kelvin Battle
Kent
City
D ay Telephone: 425-2581-0356
WA
State
E -Mail Address: kelvin @pmghvac.com Fax Number: 253- 867 -5775
98032
Zip
Contractor Registration Number:PERFOHA15ORT Exp iration Date: 4/ 30/09
Valuation of Mechanical work (contractor's bid price): $ 19 000.00
Scope of Work (please provide detailed information): Add (1) new roof top units and air distribution.
Use: Residential: New .... ❑ Replacem ent .... ❑
Com mercial: New .... Replacem ent .... ❑
Fuel Type: Electric g Gas ..❑ Oth er:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <I00K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /I00,000 BTU
Furnace> 100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall /Floor
Mounted Heater
Ventilation System
Wood /Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/C'ooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
1
Incinerator — Comm/Ind
o \ Applications \Forms- Applications On 1..■c \3.2006 - Permit Application.doc
Revised- ) -20110
bh
Page 4 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: Kelvin Battle
Mailing Address: 25500 74th Ave S
Date: 1, 2Z• /9
D ay Telephone: 425 -251 -0356
Kent
city
WA 98032
State
Zip
Date Application Accepted:
OtI 2
d Date Application Expires:
o
01 IT7
Staff Initials:
1
'iT'
Q \Applications \Forms - Applications On Lune \3 -2r06 - Permit Application.doc
Rey ised: 9-2006
bh
Page 6 of 6
CiR of Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R10 -00105
Initials: JEM
Payment Date: 01/22/2010
User ID: 1165 Total Payment: 479.01
Payee: PERFORMANCE HEATING & AIR CONDITIONING, INC.
SET ID: S000001334 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member
EL10 -0043
M10 -008
TOTAL:
Amount
67.20
411.81
67.20
TRANSACTION LIST:
Type Method Description Amount
Payment Check 51685 479.01
TOTAL: 479.01
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.101.00.0
000.322.102.00.0
000.345.830
67.20
329.45
82.36
TOTAL: 479.01
PAYMENT
RECEIVED
INSPECTION RECORD
Retain a copy with permit
INSPE• iN NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36
P7/0-00g
0
Project:
Type of Inspection:
\
Ad ess: .3
q35 S /3 s i
Date Called:
Date:
Special Instructions:
Date Wanted:
2 —iS — /v
a.m.
Vim:
Requester:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
A A
►gal ii (A — %■l
— 4 _ rr,./Q
A
Date:
Ns, rc A 14
_ — gyp,
Inspe or
YfLaitIA J
A A
/4
A
A
Date:
02
L`1.It
IRec
6Q'00 REINSPECT1 N FEE REQUII
ayt! at 6300 Southcenter Blvd., Sul
'pt No.:
ED. Prior to inspection, fee must be
e 100. Call to schedule reinspection.
Date:
INSPECTION RECORD
Retain a copy with permit M %41
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project
ev
Type of Ins %pectio�
) /�/f,,
Address.
Lim► 5
/ %%—
flake,
Date Called: Q%
Special Inst ctions:
Date Wanted:
2 -/f -/f7
"-a.mil.
p'
Requester:
Phone No:
Approved per applicable codes. El Corrections required prior to approval. j..
COMMENTS:
S cf le-eh
ho
19,4 ,: -i <,( fir' flh'
• ❑ $60. ' ' EINSPECTION EE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
• i
TL
ENGINEERING
FILE COPY
17924 -140h Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone: (425) 814 -8448
Fax: (425) 821 -2120
Structural Calculations
REVIEWED FOR
CODE COMPLIANCE
APPROVE
JAN1 2 8 2010
City of Tukwila
BUILDING DIVISION
for
Bay Value Services
Support of Proposed HVAC Unit
January 19, 2010
/ 0
cm�u�u►
JAN TQ 2010
PERMIT CENTER
BTL
ENGINEERING
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone (425) 814 -8448
Fax (425) 821 -2120
Calculations
BTL
ENGINEERING
i
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone (425) 814 -8448
Fax: (425) 821 -2120
Gravity Support
r T
I � �
1
1
�..w..w..w...�. .�...w..w..w.. ■.w..we.s.. ■.w..w..w..w.�wl..w.•••.•.•u4
I 1 1 1
in I
i.■ r.._■ .w..wt.w..w..w..w..r........w..w■ s .._..w.._.._.t A.._.._.._..*
I I I x N IQ_ I I
I I
... w■ .■..w..w4•w•.w.......•w••�.•w•• ■ Ey)
. } ■.w..w..w..n....}.....w..w..w..i
1
I .11:1 tilxti
I
I
I
. •� 0. % ■ 4
I AI I i I I
I I
.._ ••w••■..• .-. .- ..11MIN..w..1-..w..w. ■w.■ 1 ■w. ■w.. w..w.$ -.. -.. w..w...f
I
1 Ai I
11...w..w111w11111w,111w111110.■w11.w11111 ■.11•1011. ■■. ■•.■ 1111111•1•111131•1•1111111=11111111=1•O w.. -.. -.. w..�
I I I I I I
I 1 I 1 I I
I I
I I I I I I
1 I I
BTL
ENGINEERING
17924 - 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone 425 -814 -8448
Fax 425 -821 -2120
C�F�K 1 X..7... :. ::.5.110- Puna m/S •
vat*
lbr
M. o:711
2Xy of
�b = 1.1150
Co =
4 L:: /
5- :at,.
7
7/
A-
kF
r
(.10 r
314211
PSI /{RP
/1210 = /4/co ( tic) -y.de4
1-0Q 2Zc r 1t- #Z
4/ff CK Y�X�Y PGIRGt,+W. its 4
''44
10*
C9. &'t 0•127
320 2t y
=
h'XPr R "eri nF #/
F6.= /f-cio .P5/
5= /3J,(07/4,Z
Cp b/5-
/5-04)070.47 / -IS
%z vdo
`d. 74. /t,r,r
Project
Project Number:
Client
Designed By:
Scale:
Date
Pte. 6-2-
BTL
ENGINEERING
i
17924 —140th Avenue NE, Suite 220
Woodinville, WA 980724315
Phone (425) 814 -8448
Fax: (425) 821 -2120
Seismic Support
Conterminous 48 States
2006 International Building Code
Latitude = 47.384341667
Longitude = - 122.279041667
Spectral Response Accelerations Ss and S1
Ss and S1 = Mapped Spectral Acceleration Values
Site Class B- Fa= 1.0,Fv= 1.0
Data are based on a 0.05000000074505806 deg grid spacing
Period Sa
(sec) (g)
0.2 1.306 (Ss, Site Class B)
1.0 0.445 (S1, Site Class B)
•
Bay Value Services Mechanical Unit
10- 199 -02
Revision Date:
1/18/2010
Occupancy Category: [i - other Structures
Seismic Use Group: I
IE = 1.00 (Seismic Factor)
Is = 1.00 (Snow Factor)
I w = 1.00 (Wind Factor)
Site Class:
iv] ] IBC Table 1604.5
D
•
Fa = 1.00
F„ = 1.56
ASCE Table 11.4 -1
ASCE Table 11.4 -2
Design Spectral Response Acceleration:
SMS = F,SS
= 1.31
SaS = %SMS
= 0.87
ASCE Table 20.3 -1
SM1 = F„S1
= 0.69
SD1 = %SM1
= 0.46
5
2.
Bay Value Services Mechanical Unit
10- 199 -02
Revision Date:
1/18/2010
Seismic Forces
Component Operating Weight r Ibs
F = 0.4 ap Sos Wp
Rp/ Ip
F = 267 Ibs
F p need not exceed:
F = 1.6 Sos Ip Wp
F = 889 Ibs
F p shall not be less than:
F = 0.3 Sos Ip Wp
F = 167 Ibs
Dimensions:
x=
z=
Curb Height =
Check Uplift:
Mor = 8532 lb-in
MRESIST = 11771 lb-in
tie IFT ec32
M
[1 +2 (z/h)] ASCE Eq. 13.3 -1
ASCE Eq. 13.3 -2
ASCE Eq. 13.3 -3
z
Curb Height
FP
w
F.S. = 1.4 <_ 1.5
rst NOT O.K.
tot/Lt /3r T r 5or.vRo
11P i¢ TY'.4ch INfiN7_
See P4 &E s -� .
BTL
ENGINEERING
17924 - 140th Avenue NE, Saute 220
Woodinville, WA 98072 -4315
Phone: 425 - 814 -8448
Pam 425 -821 -2120
AWCH -of Qf ANT 2 " $
Z6 7#
J
iiY
131#
131
r.
/ 5 44 57i241 !y/
/ 2 5eiat,.1 /N pAswg
15t)'
jZw
sz (1)
rrnAP
r5,0 (J Sf7rFP
t'j$ (2) STgAR 5 /14cd f/D4
ANciii0/1 -64x OF C cog 779 I C/ 3e /614.41/4-i-
•
t;44- /n,ro k1vdJ FRaist /rVG.:
5h142 . /604'
Tff/V5 /01/ e- Zgy"` X 3" 7 70Z.
es 4s (2) Mc- 5(/trw5
Project: 03 4 y oV vluy5
Designed By Date:
Project Number: J( ` /9 i - 0 2 Client:
Scale: Page: 5 -Y
BTL
IMMENEEMEEMO
ENGINEERING
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone: (425) 814 -8448
Fax (425) 821 -2120
Details
r4
4
t
r
)4 tN r tli
••1't
z�4
1
T T fi
I
I I
.... ■.. ....■... ��... �.. �.... �. ..a�..�...........Uaa�aa...�.ar 1 ..... -.. a.. ■T ■ s.a. a■a.......s..�
I I I
I i I i 1 i
.....■.....a..m.1 .Mmes ■...aam■1— — aaa.11 -11 .•4
11.1 ■ a.■■
1 1 1
1
d
•. .... a.... t.. ■ a.•. ■ ao...os...I
I
'
I r
I I
*..— . ■—.....1 aa� iaa. .aa■...0.aa■1.a0..aaamasamaaam...t ■aka. ao
I
\I ate.. aaoslom.. a.�.a a.�. a..� aa�
I I
4041X4
V.I I I
11•..••••..■.......•■ {._..■...�..�.. j....�..�...�.....,�..�..�.:�•� ...........■a..rt
i r 1 Pill I
la..-11.. ...... U— f 1 a.•t a..•.. -..-11 ••••••11•1811=111 ••■••■111••11- �... U1- a.- 1...e a..1 I
I
1 1 1 1
■ 4.11s.aa�.....s•.s..+.a...■ �....•.....■■ j��.... oa.. m......... �j.■........ ■ ■...•.....}men.....a.... ■ ■... ■■4
11 t ill I
I
I
teasa.. 1.—•. .a.. /— }.- 11...1.m......11ana.... 1•— 11..... 1=4. 1—..as.......... a} ..— a.— ..sue..*
I 1 1 1
1 1 1 1
1 1 1 1
i 1 1 I
1
as
FASTEN RTU -1 TO ROOF CURB
W/ 18 -GA. STEEL STRAP.
SCREW STRAP TO ROOF CURB
& UNIT BASE RAIL. TWO STRAPS
EACH CORNER (8) TOTAL.
6X36 GLB
UNIT
NEW CURB
563LBS
75L8S
TOTAL WEIGHT 638LBS
4X14 D.F.
FASTEN CURB TO ROOF WITH
3 /8X3" LAG SCREWS INTO GLB
& D.F. (4).
#14 SCREWS THRU CURB
FLANGE INTO ROOF
STRUCTURE, TYP. OF (8).
ATTACHMENT DETAIL
NTS
07 -01 -2010
KELVIN BATTLE
25500 74 AV S
KENT WA 98032
City S o u A .� O
la
Department of Community Development
RE: Permit No. M10 -008
4385 S 133 ST TUKW
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and /or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 08/18/2010 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
c
Bill Rambo
Permit Technician
xe: Permit File No M10 -008
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
0 PER ITCOORDCOPIAlli
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -008 DATE: 01 -22 -10
PROJECT NAME: BAY VALVE SERVICES
SITE ADDRESS: 4385 S 133 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS: :
dingD l u 4V
Public Works
n
AM ivA- i�s-(o
Fire Preven on Planning Division
Structural
Permit Coordinator n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete n
Comments:
Incomplete
DUE DATE: 01-26-10
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Building
Please Route ❑ Structural Review Required
REVIEWER'S INITIALS:
No further Review Required n
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DUE DATE: 02-23-10
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Untitled Page
•
•
General /Specialty Contractor
A business registered as a construction contractor with Lftl to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
PERFORMANCE HEATING It
A/C INC
4252510356
25500 74TH AVE S
KENT
WA
98032
KING
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration
Date
Suspend Date
Specialty 1
Specialty 2
600601386
ACTIVE
PERFOHA15ORT
CONSTRUCTION
CONTRACTOR
12/30/1985
4/30/2011
GENERAL
UNUSED
Business Owner Information
Name
Role
Effective Date
Expiration Date
MILLER, DANIEL E
PRESIDENT
11/27/2007
Bond
Amount
ERDAHL, DARRIN
VICE PRESIDENT
11/27/2007
748802C
GOWIN, RICHARD L
VICE PRESIDENT
01/01/1980
GOWIN, CONSTANCE F
VICE PRESIDENT
01/01/1980
11/15/2007
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
10
DEVELOPERS
SURETY Et
INDEM CO
748802C
10/01/2007
Until
Cancelled
$12,000.0011
/27/2007
9
DEVELOPERS
SURETY it
INDEM CO
853803C
04/28/2002
Until
Cancelled
12/24/2007
$12,000.0004/23
/2002
8
DEVELOPERS
SURETY It
INDEM CO
853803C
12/29/200004/28
/2002
$6,000.00
07/27/2001
7
DEVELOPERS
INS CO
853803C
12/01/200012/29
/2000
$6,000.00
11/22/2000
6
AMERICAN
BANKERS INS
CO
LPM350055
12/01/1997
Until
Cancelled
12/07/2000
$6,000.00
5
AMERICAN
BANKERS INS
LPM350055
12/01/199412/01
/1997
$6,000.00
4
INDIANA
LUMBERMAN'S
SBP12125920
12/01/1991
12/01/1994
$6,000.00
Page 1 of 2
https://fortress.wa.gov/lni/bbip/Detail.aspx 01/29/2010
RTU -1 : 82 dB(A)
FASTEN RTU -1 TO ROOF CURB
W/ 18 —GA. STEEL STRAP.
SCREW STRAP TO ROOF CURB
& UNIT BASE RAIL. TWO STRAPS
EACH CORNER (8) TOTAL.
64X36 GLB
SITE PLAN
SCALE: 1/64" = 1' -0"
4X14 D.F.
FASTEN CURB TO ROOF WITH
3/8X3" LAG SCREWS INTO GLB
& D.F. (4).
#14 SCREWS THRU CURB
FLANGE INTO ROOF
STRUCTURE, TYP. OF (8).
ATTACHMENT DETAIL RTU -1 &2
NTS
GAS METER
0
AUO 18 2010
r
NEW VOLUME DAMPER IN NEW
BRANCH DUCT, TYP.
V
-C
SHOEMAKER 105P TRANSFER
GRILLE, NECK SIZE TO MATCH
FLEX DUCT SIZE, TYP. OF (6)
GAS PIPING BY 07NER UNDER
SEPARAIF APPlCA710N.
HONEYWELL 7 —DAY
PROGRAMMABLE THERMOSTAT
TYP OF (1).
HONEYWELL 7 —DA Y
PROGRAMMABLE THERMOSTA T
TYP OF (1)
RV
SHOEMAKER 600T SER /ES TYP. OF (1)
I s f
L_\
SHOEMAKER 700MA, TYP. OF
(4)
;300
NEW INSULATED FLEXIBLE DUCT, ---1-1--\\
TYP.
9 9
II IS IN
INSTALL RTU -1 PER ATTACHED
STRUCTURAL CALCULATIONS.
VICINITY MAP
NO SCALE
eta
tea
IPA
7
ffice
co
414 D..
300
WUNO
x®10 "0 iI+
Or
,
gig
ofh
9I
i •
.1145
ill
.
eis
sza
as
17
8"
Ira
eta
►•
12 Ker
IWO
Oft
145
►�
CM
Jgr
Orb-
iO "0
ir4
280
12 "0
t9
12 "0
18 "0
as
aa
aar
ffic
r\-\,
4-
O
REVISIONS
No changes shalt be made to the scope
of work without prior approval of
Tukw�Ia�u ding- Division.
o 's! wtreq , a new p an submittal
and may_1n Jude addition Ian review fees.
Wis
.
IMP
1`
8,
flic
145
,Pkw
.. „ r
air
a 4t WA, A00
e4141 -
*ID
10',
280:
IOWip
8"
9!
sir
14"0
m
CD
M
Inlet
PARTIAL HVAC PLAN
SCALE: 1/4 =1':0
KING COUNTY PARCEL NO.:
2613200133
LEGAL DESCRIPTION:
FOSTORIA GARDEN TRS POR S OF W W BECK RD & VAC ST ADJ LESS POR
N & W OF LNS BEG ON CO RD 157 FT S OF BECK RD TH E 138 FT TO
NXN LN BEG ON BECK RD 142 FT E OF CO RD TH S 127 FT TGW POR LOT
48 RIVERSIDE INTERURBAN TRS POR S OF W W BECK RD EX N 157 FT
MEAS ALG RD
■
11 110
4X14 D.F.
1 P
EXISTING 3 " R— 1 1 BAIT
INSUL. W/ 2X FURRING TYP.
AROUND EXTER /OR PERIMETER
AND R -11 TYP. ON INTER /OR
PERIMETER.
4ts1'i.,y Cei/ii;
_p her64.ss ( ,71y1s
FILE C
Permit No., 1110"*008
Plan review approval Is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledgcr`
By�
Date:
City Of Tukwila
BUILDING DIVISION
SCOPE OF WORK:
PROVIDE & INSTALL (1) NEW 4 —TON ROOFTOP GAS PACKAGE UNIT. NEW
UNIT TO BE INSTALLED ON NEW FACTORY ROOF CURB. FASTEN UNIT TO
NEW CURB , FASTEN NEW CURB TO EXISTING ROOF STRUCTURE. SEE
ATTACHED STRUCTURAL AND SEISMIC CALCULATIONS FOR RECOMMENDED
FASTENING METHODS. CONNECT NEW UNIT TO EXISTING LINE VOLTAGE &
LOW VOLTAGE U11U11ES.
PROVIDE NEW AIR DISTRIBUTION FROM NEW UNIT.
GAS PERMIT BY OTHER UNDER SEPARATE APPLICATION.
CODE NOTES:
1) SEAL DUCTS PER W.S.E.C. SECTION 1414.1.
2) INSULATE DUCTWORK PER W.S.E.C. TABLE 14 -6.
3) PROVIDE ECONOMIZER REQUIRED PER W.S.E.C. SECTION 1433.
4) A 110V CONVENIENCE OUTLET SHALL BE WITHIN 25' -0” OF OUTDOOR
EQUIPMENT PER I.M.C. SECTION 306.4.1
5) ROOF ACCESS TO EQUIPMENT TO COMPLY WITH I.M.C. SECTION 306.5.
ES ECONOMIZER, BAROMETRIC RELIEF DAMPER & ROOF CURB.
3z p cirtA/zC Pcc)o/c
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
ietlectrical
plumbing
Iii! •ffas Piping
of Tukwila
DI\ /ISION
REVIEWED FOR
CODE COMPLIANCE
APPROVE
JAN 2 8 2010
.tom
City of Tukwila
BUILDING DIVISION
CIIYUFTUKNAIA
JAN 2 2010
PERMIT CE
-001?
0
0
n
0
0
°n
0
0
0
0
0
n0
0
0
0
0
0
0
0
0
0
n
0
r
0
0
X
It
H
a
HVAC PLAN & GENERAL
INFORMATION
AUO 18 2010
Bay Valve Services
4385 S. 133rd St
0■ 0
00
Q3
c
H
1/22/10
KB
MS
APPVD:
JOB NUMBER:
3359 -10
M1
SHEET 1 OF 1
HVAC EQUIPMENT SCHEDULE
TAG
MANUFACTURER
DESCRIPTION
MODEL NO.
NOMINAL
TONS
CAPACITY - BTUH
SEER
CFM
E.S.P.
FAN HP
ELECTRICAL
SOUND
dB(A)
WEIGHT
(LBS.)
OUTSIDE AIR (CFM)
REMARKS
HEATING
COOLING
VOLTS
PHASE
MCA
MOCP
RTU -1
TRANE
ROOFTOP PACKAGE GAS
YSC048E3RMA0001
4.0
64,000
49,450
13
1,600
0.6
.75
208
30
25.2
35
82
*638
* *320
WITH FACTORY ROOF CURB & ECONOMIZER.
ES ECONOMIZER, BAROMETRIC RELIEF DAMPER & ROOF CURB.
3z p cirtA/zC Pcc)o/c
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
ietlectrical
plumbing
Iii! •ffas Piping
of Tukwila
DI\ /ISION
REVIEWED FOR
CODE COMPLIANCE
APPROVE
JAN 2 8 2010
.tom
City of Tukwila
BUILDING DIVISION
CIIYUFTUKNAIA
JAN 2 2010
PERMIT CE
-001?
0
0
n
0
0
°n
0
0
0
0
0
n0
0
0
0
0
0
0
0
0
0
n
0
r
0
0
X
It
H
a
HVAC PLAN & GENERAL
INFORMATION
AUO 18 2010
Bay Valve Services
4385 S. 133rd St
0■ 0
00
Q3
c
H
1/22/10
KB
MS
APPVD:
JOB NUMBER:
3359 -10
M1
SHEET 1 OF 1