Loading...
HomeMy WebLinkAboutPermit M10-011 - WESTFIELD SOUTHCENTER MALL - PHARMACITYPHARMACITY 1368 SOUTHCENTER MALL SUITE 130 M10 -011 Parcel No.: 9202470010 Address: Suite No: Citylkf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT 1368 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: M10 -011 04/16/2010 10/13/2010 Tenant: Name: Address: Owner: Name: Address: PHARMACITY 1368 SOUTHCENTER MALL, STE 130 , TUKWILA WA WEA SOUTHCENTER LLC BSIP Phone: TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247 Contact Person: Name: BILL BEEBE - NADEL ARCHITECTS Address: 1990 S BUNDY DR 4TH FLOOR , LOS ANGELES CA Contractor: Name: TILTON PACIFIC CONST INC Address: 4150 CITRUS AV , ROCKLIN CA Contractor License No: TILTOPC909CP Phone: 310- 826 -2100 Phone: 916 -630 -7200 Expiration Date: 02/16/2012 DESCRIPTION OF WORK: REUSE EXISTING RTU'S, REDISTRIBUTE SUPPLY /RETURN AIR DUCTS, NEW HOODS & EXHAUST FANS, NEW AIR HANDLERS Value of Mechanical: $10,000.00 Type of Fire Protection: SPRINKLERS /AFA Fees Collected: $301.56 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 5 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment0 * *continued on next page ** doc: IMC -10/06 M10-011 Printed: 04 -16 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us Permit Number: M1O -011 Issue Date: 04/16/2010 Permit Expires On: 10/13/2010 Permit Center Authorized Signature: L,),stu Date: 4-.(,(0-0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the Berfprmance of work. I am authorized to sign and obtain this mechanical permit. Signature: Uvv Date: t Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M10 -011 Printed: 04 -16 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, .Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 9202470010 Address: 1368 SOUTHCENTER MALL TUKW Suite No: Tenant: PHARMACITY Permit Number: M10 -011 Status: ISSUED Applied Date: 01/26/2010 Issue Date: 04/16/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) (EXISTING DUCT doc: Cond -10/06 M10 -011 Printed: 04 -16 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DETECTION TO MEET CURRENT CODE REQUIREMENTS AND BE TIED TO THE MAIN MALL FIRE ALARM PANEL AND MUST BE TESTED.) 16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 19: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. 1f you have any questions, please call Tukwila Fire Prevention Bureau at (206) 575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -011 Printed: 04 -16 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. C(ri .� Signature: Date: Print Name: A (A, doc: Cond -10/06 M10 -011 Printed: 04 -16 -2010 CITY OF TUKWI Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No; Mechanucal Pernnt No^ Plumbing/Gas Permit No Public Works Permit No: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 434'8 6DD Tenant Name ei )e e'"' G-) �-; � Property Owners Name: W 61 i3 Mailing Address: /IAN f King Co Assessor's Tax No.: 9Z z 71 J t� Suite Number: Floor: New Tenant: Yes ❑..No City State Db Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: in L d Day Telephone: �� 0 8 Z46 Mailing Address: /,,a �� OuNP l PP1 ' LD lj /412, �.�� City State Zip E -Mail Address: Feg�� TJIj.p.c /" / n Fax Number: 8 2b —Z) j 4 2 GENERAL CONTRACTOR INFORMATION — (Contractor Information for. Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: -rg p Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD =All plans must be wet stamped by Architect of Record Company Name: tiAlg l/ Mailing Address: ) / f 0 - 19 Ur•Ip Y tPt 4 ,N ;rEf 4 Cs1,!- ,f)Q City State Zip Contact Person: �% i� Day Telephone:I 0 'I$ 2� 2 f fla E -Mail Address: � �� � Fax Number: 3 y D'— £ge-- Z `Z--- "ENGINEER OF.RECORD_ -All plans must be'wet stamped by Engineer of Record Company Name: Mailing Address: Al A ?i0 Contact Person: /4)44 -' E -Mail Address: 8 & H:\Applieations\Fonas- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh City State Zip Day Telephone: // — —8 i B Z Fax Number: b 45 r 44.13 `— 8 0 / Z Page 1 of 6 • • MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide detailed information): v I� )61 isC40 U /JI T'U j j// 6 Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ..X Replacement .... ❑ Fuel Type: Electric ❑ Gas.., Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser J 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat ) / 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM / Incinerator — Comm/Ind fi-Of-Av477 H:\Applications\Poms- Applications On Line\2009 Applications \I -2009 - Permit Application.doe Revised: 1 -2009 bb Page 4 of 6 PERMIT APPLICATION NOTES — Applicable, to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: jDate: Print Name: k/) L. L /NAPv Day Telephone: 3JO -1126---0)00 Mailing Address: / JD . a.1 J vf^ LD City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H: Applications\Fonns- App &cations On Line \2009 Applications \1 -2009 - Permit Applicatioadoc Revised: 1 -2009 bb Page 6 of 6 City of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http : //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R10 -01141 Initials: WER User ID: 1655 Payee: ALAN G REEVES Payment Date: 06/24/2010 Total Payment: 693.00 SET ID: 0624 SET NAME: SEAFOOD CITY REVISIONS SET TRANSACTIONS: Set Member Amount D10 -022 D10 -023 M10 -010 M10 -011 PG10 -007 PG10 -009 TOTAL: 378.00 63.00 63.00 63.00 63.00 63.00 378.00 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA ACCOUNT ITEM LIST: Description TOTAL: 693.00 693.00 Account Code Current Pmts BUILDING INVESTIGATION MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES 000.322.800 000.322.102.00.0 000.345.830 000.322.103.00.0 378.00 126.00 63.00 126.00 TOTAL: 693.00 Citfof Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R10 -00653 Initials: JEM Payment Date: 04/16/2010 User ID: 1165 Total Payment: 21,615.65 Payee: DUKWILLA SEAFOOD CITY SUPERMARKET SET ID: 0127 SET NAME: SEAFOOD CITY SET TRANSACTIONS: Set Member Amount D10 -019 1,794.06 D10 -021 3,126.40 D10 -022 8,680.80 D10 -023 1,678.56 EL10 -0053 436.50 EL10 -0055 522.50 EL10 -0056 223.13 EL10 -0057 264.50 EL10 -0058 2,843.40 M10 -009 290.25 M10 -010 388.25 M10 -011 241.25 M10 -012 1,126.05 TOTAL: 1,794.06 TRANSACTION LIST: Type Method Description Amount Payment Check 001027 21,615.65 TOTAL: 21,615.65 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES MECHANICAL - NONRES STATE BUILDING SURCHARGE 000.322.100 000.322.101.00.0 000.345.832.00.0 000.322.102.00.0 640.237.114 15,261.82 4,245.40 44.63 2,045.80 18.00 TOTAL: 21,615.65 COP of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R10 -00124 Initials: WER Payment Date: 01/26/2010 User ID: 1655 Total Payment: 1,260.40 Payee: TSP FIRST HEALTH LLC SET ID: 0126 SET NAME: PHARMACITY SET TRANSACTIONS: Set Member Amount D10 -023 1,108.50 EL10 -0057 66.13 M10 -011 60.31 PG10 -009 25.46 TOTAL: 1,108.50 TRANSACTION LIST: Type Method Description Amount Payment Check 1026 1,260.40 TOTAL: 1,260.40 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.322.100 000.345.832.00.0 000.345.830 TOTAL: 12.34 66.13 1,181.93 1,260.40 PAYMENT RECEIVED INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1s5 mt0 -0�( CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Prod C'I Gf/'/bIGtC� Type of Inspection: rr F;Aa ,ME' -A . Address: Date Called: Special Instructions: Date Wanted: �d — �' /C� p.m. Requester: PhogNp6 yiZ —o ZiS Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: -ciPsen AM. Inspector: C4c- El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectiow Dates 2011) Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION e 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: P h A f/Y1 •-f y Type of Inspection: 1 ?n (,) h- kd Address: Date Called: Special Instructions: Date Wanted: G -2_ 51 - / b a.m. p.m. Requester: Phone No: EApproved per applicable codes. ❑ Corrections required prior to approval. 1/ COMMENTS: .��1,h —RAJ — /4`pp ✓4/9f 074- 60 I Date: - 2 if—ft, 0 REINSPECTION FEE I QUIRE . Prior to inspection, fee must be at 6300 Southcenter Blvddd , Suite 100. Call to schedule reinspection. Receipt No.: Date: ANS INSPECTION NO. INSPECTION RECORD Retain a copy with permit pi) to- ©1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PFON Typ of In ection: Address: ! Date Called: Special Instructions: Date WI- -2 r 0 Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: G) T to' �r� -4 � I _ wood Inspect Da( - Z 3 / 0 60.0 REINSPECTION FE REQUIRED 'riorto inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Re eipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 /72/0-0// Project: . � 'hAvpvr•y of spect'on: , A' 'No - ■,../ Address: /314' 56,/-1A,01/4V Date Called: Special nstructions: Date Wanted: 6 : : Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. / COMMENTS: './t - O,L 70 TnlSr//, e,° n s pect 0.00 REINSPECTION FE REOU;ED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dat"i Receipt No.: Date: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit e -) 0 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: � v v L,v c' CI I _Lii Type of Inspection: / e i ry?- Address: i-, •, ` Suite #: ,C f; A0s'_C' t'� Contact Person: // fz�. ,,/, j �' /�` G �/j ,2 --� . Special Instructions: Phone No.:(r,7)77`` C7? Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Ji/1 -,'/.A - 7,;ar. c>L r /1 / 1 ' . ; il — /4 fl / k 1 / ( r 1 ---t i .rAr i f n/ . .� , t' U r Gi !. / . 1- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: \i61 Date: -7 1q (6 Hrs.: - 5` $80.00 REI CTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Fina ce Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 INSPECTION NUMBER CITY OF TUICWI 444 Andover Park East, Tukwila, Wa. 98188 PERMIT NUMBERS ENT 206- 575 -4407 Project: tN` G L 1 Sprinklers; Type of Inspection: A• Address: 12,c., Suite #: t c c . ,,,,,,o,A Contact Person: 4 ) k e ,.0 Special Instructions: Occupancy Type: Phone No.: To 5117-07 s- CApproved per applicable codes. Corrections required prior to approval. COMMENTS: 1 Sprinklers; Fire Alarm: Flood & Duct: Monitor: Pre-fire: Permits: Occupancy Type: -1 to - =- i t u t Ia ),.R.14.1,- ;Op+ V Z_-!' 0,1k. M r °': om: �C Needs Shift Inspection: Sprinklers; Fire Alarm: Flood & Duct: Monitor: Pre-fire: Permits: Occupancy Type: Inspector: _. Mr c. Hrs.: , $80.00 REIN CTUON FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Coil to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 • • Carol E. Martin Building Division City of Tukwila Department of Community Development 6300 Southcenter Blvd. Suite 100 Tukwila, WA 98188 (206) 431 -3670 Please consider the following responses provided to satisfy the comments made for plan check # M10 -011 In reference to Pharmacity located at 1368 Southcenter Mall Suite #130 Tukwila, WA 98188. Response to Comment #1: See updated T1.0 scope of work Response to Comment #2: See updated sheet T1.0 — applicable codes Response to Comment #3: See updated sheet T1.0 — bldg. summary Response to Comment #4: Refrigeration drawings only apply to Seafood City Market submittal. Response to Comment #4_a: See updated sheet index/T1.0 Response to Comment #5: See sheet M -1, irrelevant items has been deleted and relevant code info. added to general notes. Response to Comment #6: See sheet M -1, smoke detectors location changed from supply to return air. Also general note #14 corrected. Response to Comment #7: Refrigeration drawings only apply to Seafood City Market submittal. Response to Comment #8: See 2/A -1.3 — uni -sex toilet does not open directly to kitchen/prep area. • • Response to Comment #9: See sheet M -3, roof plan has been added and all sheet numbers after this has been changed (old M -3 is M -4 now, old M -4 is M -5 now and old M -5 is M -6 now). Response to Comment #10: (old M -3) See sheet M -4, hood system general notes revised. Response to Comment #11: Illegible font size has been adjusted to acceptable font size. Response to Comments #12, 13, 14 & 15: All notes has been added to new sheet M -4 (old sheet M -3). Response to Comment #16: There will be no requirement for a type II hood for the commercial dishwasher used at cooking locations. Response to Comment #17: See attached equipment cut sheets. Sincerely, Bill Beebe Nadel Studio One, Inc. 1990 S. Bundy Dr. Fourth Floor Los Angeles, CA 90025 Cc: File • of T a • Jim Haggerton, Mayor Department of f Communityi % eVelopment Jack Pace, Director February 22, 2010 Bill Beebe — Nadel Studio One 1990 S Bundy Dr 4th Floor Los Angeles, CA 90025 RE: Correction Letter #1 Mechanical Permit Application Number M10 -011 Pharmacity —1368 Southcenter Mall Suite 130 Dear Mr. Beebe, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Carol Martin at 206 431 -3677 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File: M10 -011 W:\Pennit Center \Correction Letters \2010\M10 -011 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 ® Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 • • Tukwila Building Division Carol Martin, Plans Examiner Building Division Review Memo Date: February 22, 2010 Project Name: Pharmacity Permit #: M10 -011 Plan Reviewer: Carol E. Martin, Plans Examiner (GENERAL NOTE) PLAN SUBMITTALS: (Minimum size 11 x 17 to maximum size of 24 x 36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) The Building Services has completed its Plan Review for the proposed Mechanical portion of the Seafood Market. This letter summarizes our review and the revisions required on your next submittal. 1. The scope of work for this permit indicates general demolition and addition of service door. Please change scope of work to identify specific scope of work relative to this permit. Cloud the specific areas of work and provide only the specific plan drawings and details relative to the scope of work indicated. 2. Refer to Sheet TI.0. Revise and submit a new Title Sheet. Under "Applicable Codes" include relevant Code information. A. Add 2006 International Building Code Chapter 11 adjacent to note #2 — ICC /ANSI A117.1 (2003) Accessible & Usable Buildings & Facilities. B. Add 2006 International Fuel & Gas Code C. *All with WA State Amendments 3. Refer to Sheet T1.0. Revise and Submit additional relevant Code information with regards to "Type of Construction" of structure for Tenant Improvement per Chapter 6 of the 2006 IBC. This is relevant information because Contractors should be aware of requirements / compliance issues for Non - Combustible Types of Construction as well as sprinkler requirements / information. *These Documents /Drawings become a matter of "Public Record" and should reflect all pertinent information associated with the project. 4. Refer to Sheet T1.0. Refrigeration Sheets are not included within submitted plans. Revise and submit Sheets R1.0 through Refrigeration Schedule as indicated on "Title Sheet ". *If this is a Deferred Submittal, the Building Official must approve a formal request for deferment. 4. Refer to Sheet TI.O. Why is there a Note at the base of all Title Sheet submittals for Building, Plumbing, Mechanical, etc. reading: "These Drawings are included for the contractors use as convenience to the owner. They are not a part of the contract documents prepared by the Architect. They were prepared by others not employed by the Architect and are not a part of the work of the Architect, who takes no responsibility for their accuracy "? *Please Confirm who the WA State Registered Design Professional is for the Seafood City Market Place. Confirm this information within your next response and Wet Stamp all Architectural, Mechanical, Structural, Electrical, Fuel & Gas, Plumbing, etc. The General Note indicating "No Responsibility" shall be stricken on your next submittal. Remove entire • • paragraph & statement. 5. Refer to Sheet M -1. Revise and submit relevant Code information within the General Notes. Note #11 should include information - indicating requirements for Duct Insulation for Supply and Return Air. This should also include 2006 International Mechanical Code / SMACNA & WA State Amendments / 2006 WA State Energy Code. Note #16: Replace "Los Angeles" with "Tukwila ". Note # 22: Replace "CMC Table 6 -7" with "2006 International Mechanical Code / SMACNA ". 6. Refer to Sheet M -1 Detail # 2 & 4. Per Section 606.2.1 of the 2006 IMC — Smoke detectors Shall be installed in the "Return Air" systems with a design capacity greater than 2000 CFM in the exhaust air connections, outdoor air connections, or decontamination equipment & appliances. (Not Supply) Revise information accordingly: A. A general note indicating compliance with Section 606.3. Smoke detectors required by this section shall be installed in accordance with NFPA 72. Access to be provided for inspection & maintenance. B. Section 606.4. Upon activation the smoke detectors shall shut down ALL operational capabilities of the air distribution system. C. Section 606.4.1. The Duct Smoke Detectors shall be connected to a Fire Alarm System. 7. Refer to Sheet M -2. Revise and submit pertinent sheets indicated on Title Sheet for "Refrigeration," Sheets R -1 through RS. A deferred submittal requires prior approval from the Building Official. * *These Pre -Fab refrigeration units totaling "Six" separate will be counted as mechanical fixtures and an adjustment will be made on "Fixture Quantities ". Once all fixtures have been determined through the review process, total calculations will affect permit fees. Fees must be paid in full prior to release of Mechanical Approved Plans. 8. Refer to Sheet M -2. Revise and submit Re- Location of the Uni -Sex restroom adjacent to "Pinoy Kitchen ". This is a Code Violation per Section 2902.2.1.1 of the 2006 IBC WA State Amendments. 9. The next submittal shall include a "Roof Top" Plan of all equipment. 10. Refer to Sheet M -3. Revise "Hood System General Notes" to read : 2006 IMC /SMACNA & WA State Amendments. Remove 2007 California Mechanical Code compliance. 11. Note to the Architect/Designer: All notes on each sheet shall be of font size in which a magnifying glass is not required in which to read all General Notes. *This will be a condition of Plan Approval. 12. Refer to Sheet M -4. Revise and add General Notes for Type 1 Hoods & Make -Up Air. A. When the Type 1 Hood Fire extinguishing system discharges, make up air supplied internally to a hood shall be shut off. The City of Tukwila will conduct an inspection & test to insure shut down of make up air. B. Make Up Air shall be in compliance with Section 508.1 & 508.1.1 of the 2006 IMC. C. Section 506.3.1.2. Make Up Air ducts connecting to or within 18 inches of a Type I Hood shall be constructed & installed in accordance with sections 603.1, 603.3, 603.4, 603.9, 603.10 & 603.12. Duct Insulation installed within 18 inches of Type 1 Hood shall be Non - Combustible or shall be listed for the application. • • 13. Section 507.2.1.1 of the 2006 IMC. Type I Hood systems shall be designed & installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances by means of Heat Sensors or by means of other approved methods. 14. Section 506.3.3.1 of the 2006 IMC. A Grease Duct test shall be performed for the entire duct system including the Hood to Duct connection. The duct work shall be permitted to be tested in sections, provided that every joint is tested. 15. Special Inspections are required for all Grease Ducts & Hoods through a Qualified / WABO Certified agency prior to installation and /or Duct Insulation. 16. Will there be no requirement for Type II Hoods for Commercial Dish Washing at cooking Locations? 17. Please include Manufacturers Specifications for all appliances incorporated within this project. That will include the Pre - Fabricated refrigeration units. Any omissions in these review comments or errors that may be subsequently found within the plans or specifications shall not be construed as an approval to reduce or waive the requirements of the Codes. The review comments contained herein apply to the Mechanical portion & related construction. Please ensure that all changes or modifications that have occurred through these review processes, or through other revisions that effect the building plan submittal are incorporated prior to re- submittal. Every effort has been made to ensure that these comments are as complete and comprehensive as possible, however, the City reserves the right to request additional information or revisions as may be necessary upon review of re- submittal. Please review and address EACH of the remaining comments noted above and submit (3) revised plans and corresponding letter of response for our review. If there are any questions, or I can be of further assistance, please feel free to contact me via telephone at (206)431 -3677 or via e-mail cmartin @ci.tukwila.wa.us • PERMIT COORD COSY• PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -011 DATE: 06/08/10 PROJECT NAME: PHARMACITY SITE ADDRESS: 1368 SOUTHCENTER MALL, STE 130 Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DE T ENTS: ul ding Divisl n Public Works n Pon Q( NUS ay...n Fire Prevention Structural Planning Division UPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 06/10/10 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route' Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 07/08/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • PLAN1 • ROUTING SLIP ACTIVITY NUMBER: M10 -011 PROJECT NAME: PHARMACITY DATE: 03/10/10 SITE ADDRESS: 1368 SOUTHCENTER MALL, STE 130 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPART NTS: Ling Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete t Comments: Incomplete DUE DATE: 03/11/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/08/10 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • • Y PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -011 DATE: 01 -26 -10 PROJECT NAME: PHARMACITY SITE ADDRESS: 1370 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPART ( uu"ilding Division Public Works Lire Prevention ,!mac Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: DUE DATE: 01 -28-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: rn No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 02 -26 -10 Approved Approved with Conditions rn Not Approved (attach comments) e Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: (71)'-'1 0 I Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: JJK Documents /routing slip doc 2 -28 -02 PROJECT NAME: Pharmacity o PERMIT NO: ' M10-011 SITE ADDRESS: 1368 Southcenter Mall, Ste 130 ORIGINAL ISSUE DATE: 04/16/2010 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 06/08/2010 JEM Cr Ltilgt to Received by: Summary of Revision: Sheet M -1: provide fly fan schedule Sheet M -2: revise ceiling register location Received by: A 1 A,4 4,..e... REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 06/01/2010 Plan Check/Permit Number: M10 -011 O Response to Incomplete Letter # O Response to Correction Letter # El Revision # 1 after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner Project Name: Pharmacity enmarmA JUN 0 8 2010 PERMIT CENTER Project Address: Contact Person: 1368 Southcenter Mall Suite 130 Tukwila, WA 98188 Tom Nasrollahi Phone Number: (818) 348 -1556 Summary of Revision: Sheet M -1: Provided fly fan schedule as required. Sheet M -2: Revised suite 130 ceiling register location per revised ceiling /lighting plan. Sheet Number(s): M -1 & M -2 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: M/' [ Entered in Permits Plus on v1 I-PApplicationsWomu- Applications On Ltn62009 -08 Revision Submittal.doc Creased: 8 -13 -2004 Revised: 8 -2009 • • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 03 /0l /2a to Plan Check/Permit Number: M 1 0-0 1 1 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Pharmacity Project Address: 1368 Southcenter Mall Suite 13b (g10) 3410-1W0 v Contact Person: 1M 1 "Aq_1kiAl Phone Number: RECEIVED CITY OF TUKWILA MAR I 0 2010 PERMIT CENTER Summary of Revision: /trri^tv 3 Sheet Number(s): Tk - C2r lA 1 / M 3, 11- 4 , "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on (Y7 \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: 3 Contractors or Tradespeople Printer Friendly Page • • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Tilton Pacific Const Inc UBI No. 602872954 Phone 9166307200 Status Active Address 4150 Citrus Ave License No. TILTOPC909CP Suite /Apt. License Type Construction Contractor City Rocklin Effective Date 2/16/2010 State Ca Expiration Date 2/16/2012 Zip 95677 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date Tilton, James Richard President 02/16/2010 Tilton, Stephanie Kathleen Secretary 02/16/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 INS CO OF THE WEST 2304298 02/11/2010 Until Cancelled $12,000.00 02/16/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 AMERICAN GUARANTEE E LIABILITY CP0427795001 01/01/2010 01/01/2011 $1,000,000.00 02/16/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 04/16/2010 3" MAX. ACCESS DOOR DOUBLE THICKNESS VANES LONG RAII SQLJARE LBOW AIR FLOW AIR FLOW BRANCH DUCT RETUR\ TAP DUCTWORK DETAIL SUPPORT FROM STRUCTURE , MAX 4' -0" O.C; APPROVED CLASS 0 OR CLASS 1 FLEXIBLE DUCT, DIAMETER EQUAL TO DIFFUSER NECK SIZE' (MAX. I LENGTH 4'-0") ) SECURE WITH WORM DRIVE METAL CLAMP (TYPICAL) TYPICAL CEILING DIFFUSER 1 1/2 MIN. , 26 GA. RIGID DUCT WHERE BRANCH DUCT EXTENDS 1 -0 II AN LONGER D L ER BRANCH DUCT SPIN IN FITTING WITH HAND DAMPER AND LOCKING QUADRANT LAY - IN CEILING D I AGONAL WIRING BRACING SECURE TO STRUCTURE TYP. DIFFUSER CONNECTION DETAIL SCALE: NONE. LEGEND: cDACCESS HOLE 0 1/4" (6mm) DIA. ALL THREADED RODS. @:: ACCESS COVER - 16 GAUGE ® INSULATION PINS WELDED ® FIRST LAYER THERMAL CERAMIC DUCT WRAP 16A CUT SAME SIZE AS COVER. 0 SECOND /THIRD LAYER THERMAL CERAMIC DUCT WRAP 15A WITH 1" (25mm) OVER LAP ON ALL SIDES. @:: SPEED CLIPS ® ALUMINUN TAPE COVERING ALL EXPOSED EDGES ® SPOOL PIECES FOR THREADED RODS. 0 1/4" (6mm) DIA. WING NUTS. @:: GREASE TIGHT GASKET RATED FOR 1500'F NOTE: FIREMASTER FASTWARP XL MUST BE INSTALLED PER ALL SPECIFEC REQUIRMENTS OF THE PRODUCT LISTING AND IN COMPLICE WITH ERS -2213 FIGURE 2 AND ALL OTHER TERMAL CERAMICS PRODUCT DATA & INTALLATION GUIDE. THERMAL CERAMICS FIRE WRAP ACCESS DOOR DETAIL SCALE: NONE SUPPLY FAN 10' -0" MIN. ROOF EXHAUST TERMINATION - 10' -0" MIN. FROM ADJACENT BUILDING,ADJACENT PROPERTY LINE, AIR INTAKES AND 10' -0" ABOVE ADJOINING GRADE LEVEL 36"x16" EXH. DUCT 1,500 FPM TYPICAL CEILING D IFFUSER MN. CLEARANCE OF 18" BETWEEN THE TYPE -' ONE HOOD AND ANY COMBUSTIBLE MATERIAL TYPICAL IN ALL DIRECTIONS UNLESS NONABSORBENT AND NONCOMBUSTABLE MATERIAL IS INSTALLED COMPLY WITH ALL REQUIREMENTS OF 2006 UMC. NOTE: 15% OF TOTAL MAKE -UP AIR WILL DIRECTLY SUPPLY TO THE HOOD AND 25% WILL SUPPLY TO THE KITCHEN AREA AND TOTAL MAKE -UP AIR IS EQUAL TO EXHAUST AIR FROM HOOD. UL LISTED EXHAUST FAN WITH HINGED BASE, SET WITH DISCHARGE 40 INCH MINIMUM ABOVE ROOF LINE PROTECT OUTDOOR DUCTS AGAINST CORROSION TRANSITIONING' VENTILATED FROM CURB TO FAN 2x10 CONSTRUCTION, FOUR WAY LEVEL CURB BY GENERAL CONT'R -16 GAUGE STEEL ALL WELDED LIQUID TIGHT CONSTRUCTION GREASE EXHAUST GREASE DUCT WRAPED WITH APPROVED FIREMASTER FASTWRAP. 1 -1/2" THICKNESS - _�- CLEANOUT DOORS IN DUCTS 51-IALL BE SLIDING OR HINGED SEE DETAIL 3 ON SHEET M -1 MAKE UP AIR RISER WITH VOLUME DAMPER TED CEILING - STAINLESS STEEL PERFORATED PANEL COOKING EQUIPMENT UL LISTED GREASE FILTERS SEE 48" MAX. 33" MIN. DISTANCE SCHEDULE FOR SIZE AND QUANTITY BETWEEN COOKING SURFACE AND THE BOTTOM OF THE HOOD 6" MINIMUM OVERHANG BEYOND THE COOKING SURFACE ALL DIRECTIONS TYPICAL HOOD DETAIL NOTE: SHUNT ACROSS COMMON AND FAN TERMINAL TO ENSURE CONSTANT FAN OPERATION DURING TIME CLOCK 'ON' TIMES IN ORDER TO DEACTIVATE 'AUTO' FAN MODE ON THERMOSTAT UL APPROVED SMOKE DETECTOR RETURN AIR DUCT WITH ACCESS. THERMOSTAT ON -OFF, 2 STAGE HEAT, 2 STAGE COOL, AUTO CHANGEOVER WITH SUBBASE AND COVER (PROGRAMMABLE) W/ BUILT -IN TIME CLOCK. SEE SCHEDULE FOR VOLTAGE G CD C)C) W2 O G0 O W1 DISCONNECT SWITCH. FACTORY SUPPLIED ECONOMIZER i AIR CONDITIONING UNIT. C o o ED@ c LOW VOLTAGE (TYP) ®WI1NG 0 E CONDUIT PLUG (TYPICAL) UN ION CONDENSATE TRAP PER. CODE FOR CONTINUATION SEE PLUMBING DRAWINGS R.A. , '(L) ECONOMIZER ACCESSORY HOOD. M -2 FLEXIBLE CONNECTIONS INSTALLED ABOVE ROOF. UNIT INSTALLATION DETAIL SCALE: NONE GASKET NAILING STRIP, FACTORY SUPPLIED PRE -FAB ROOF CURB BY MECH. CONT. RIGID INSULATION OR PLYWOOD FILLER BY MECH. CONT. ROOF LINE MIN. 4" HIGH LEVEL PLATFORM BY GENERAL CONT. AIR CONDITIONING UNIT BOLT (TYP) SHEET METAL STRAP COUNTER FLASHING PROVIDED BY MECHANICAL CONT. ROOF FELT BY GENERAL CONT. PLYWOOD CANT BY GENERAL CONT. BUILT UP ROOFING AC UNITS PRE -FAB ROOF CURB AC UNITS TO BE ANCHORED TO THE CURB AND PLATFORM AS SHOWN ROOF MOUNTED CURB DETAIL DUCT MAY BE LINED, SEE PALN FOR SIZE 4 LINING WHERE REQUIRED SET COUNTER- FLASHING IN BEAD OF CAULKING 4 LAG TO CURB ROOF DECK TYPICAL ROOF OPENING, I" LARGER THAN DUCT SIZE. POCKET LOCK SEAL Ili/MASTIC 2x6 CURB -CUT TO SLOPE OF ROOF - TOP FLAT. 2.5 "x2.5" CANT STRIP FLASH UP 4 COVER CURB W /ROOFING DUCT THRU ROOF DETAIL SCALE: NONE GENERAL NOTES 1) THE MECHANICAL CONTRACTOR SHALL FURNISH ALL MATERIAL, LABOR, EQUIPMENT, APPURTENANCES, AND ALL CONTRACTUAL EXPENSES REQUIRED FOR THE COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM TO THE SATISFACTION OF NE OWNER, ARCHITECT AND MECHANICAL ENGINEER. 2) THE INSTALLATION SHALL COMPLY WITH 4 BE INSTALLED IN ACCORDANCE WITH ALL LEGALLY CONSTITUTED AUTHORITIES 4 CODES HAVING JURISDICTION_ ALSO ALL THE REQUIREMENTS OF LANDLORD. 3) THE MECHANICAL CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, APPARATUS, ACCESSORIES (I.E., THE ENTIRE' INSTALLATION) AS FURNISHED 5Y HIM FOR A PERIOD OF ONE YEAR_ 4) THE MECHANICAL CONTRACTOR 51-IALL OBTAIN 4 PAY FOR ALL PERMITS, LICENSES 4 INSPECTIONS` REQUIRED TO COMPLETE THIS JOB. 5) COORDINATE THE SIZE, LOCATION, e SERVICE REQUIREMENTS OF ALL MECHANICAL EQUIPMENT 4 DUCTWORK WITH THE GENERAL, PLUMBING, ELEC.CONTROL, 4 FIRE PROTECTION CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. REPORT ALL UNRESOLVED CONFLICTS TO THE ARCHITECT. 6) COORDINATE NE LOCATION OF ALL CEILING DIFFUSER, REGISTER, GRILLES 4 ETC. WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. 1) ALL SHEET METAL. DUCTWORK SHALL BE NEW GALYANIZED SHEET METAL DUCT GAUGES, CONSTRUCTION SUPPORT, AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE 2001 CMC (604) ALSO REFER TO DETAIL 1 ON SHEET M -1 AND SMACNA. S) ALL INSTALLATIONS MUST COMPLY WITH THE MANUFACTURER REQUIREMENTS INCLUDING THE OPERATION AND SERVICE CLEARANCE, PIPING, WIRING, ADJUSTMENTS AND ETC. 9) ALL TRANSVERSE JOINTS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CMC DUCT SEALER. 10) FLEXIBLE CONNECTIONS SHALL BE PROVIDED FOR ALL DUCTWORK ATTACHED TO AIR MOVING EQUIPMENT' MOUNTED ON OR SUSPENDED FROM VIBRATION ISOLATORS. FLEXIBLE CONNECTIONS SHALL BE CODE APPROVED NEOPRENE COATED GLASS TYPE FABRIC. N. PROVIDE AIR DUCTS ABOVE FIN •. Ii • to • WRAP INSULATION ON ALL NEW SUP • ABLE 6 -6 B, 2006 INTERNATIONAL MECHANICAL CODE /' - -'- MENDMENTS/ 2006 WA -o60 • ST 12) THE ELECTRICAL AND PLUMBING CONTRACTORS SHALL PROVIDE FLEXIBLE CONNECTIONS AT ALL MECHANICAL EQUIPMENT MOUNTED ON VIBRATION ISOLATORS AND OR SUSPENDED FROM VIBRATION HANGERS. 13) PROVIDE TURNING VANES AT ALL 90 0 ELBOWS FOR SUPPLY AND RETURN DUCTS. CONTRACTOR TO PAY SPECIAL ATTENTION TO WORKMANSHIP AND FABRICATION OF AIR DISTRIBUTION SYSTEM FOR MINIMUM STATIC PRESSURE. 14) PROVIDE ALL FIRE AND SMOKE DAMPERS AS REQUIRED BY LEGALLY CONSTITUTED` AUTHORITIES AND CODES A HAVING JURISDICTION_ COMPLIANCE WITH SECTION 6063. SMOKE DETECTORS REQUIRED Bl' THIS SECTION SHA LL BE INSTA LLE . N ACCORDANCE WITH NF PA 12. ACCESS TO BE PR OVI ED FOR INSPECTION ,AND MAINTANENCE. SECTION 606.4. UPON ACTIVATION THE SMOKE DETECTORS SHALL SHUT DOWN ALL OPERATIONAL CAPABILITIES OF THE AIR DISTRIBUTION SYSTEM. SECTION 606.4.1. THE DUCT SMOKE DETECTORS SHALL BE CONNECTED TO A FIRE ALARM SYSTEM_ 15) PAINT PLE NUM E ACH GR I LLE O R REG IST ER WITH FL AT BL ACK P,AINT. 16) BALANCE AND ,ADJUST ALL DIFFUSERS, REGISTERS, ETC. FOR OPTIMUM AIR DISTRIBUTION AND MINIMUM NOISE. SU MIT A CERTIFIED AI 5A LANCE REPORT TO THE M CHANICA ENGINEER FOR A OVA 5A LANCING OF B ER ED R B L E REP R E E L S EER R PPR L B L TO THE SYSTEMS SH,4LL BE PERFORMED BY AN INDEPENDENT TEST AND BALANCING AGENCY WHICH SPECI,4LLZES IN THE BALANCING AND TESTING OF HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS. ALSO PROVIDE COPY OF TI-4E TESTING AND BALANCING REPORT TO THE CITY OF TUKWILA BUILDING INSPECTOR PRIOR TO FINAL INSPECTION.- ONLY -4 QUALIFIED NEBB OR AABC BALANCING„ AGENCY MUST PERFORME THIS WORK. 11) AS -BUILT RECORD PRINTS MUST BE PROVIDED PRIOR TO JOB COMPLETION. 18) FLEXIBLE DUCT SHALL BE THERM,4FLEX TYPE MKE, CLASS I, WITH 1" EXTERNAL INSULATION. MAX. LENGTH TO D IFFUS ER 41-0". NO FLE X. DUCT IN O PE N CEILING AREA, RE F ER TO DE TAI L 2 ON SH EE T M -1. 19) ALL DUCT WORK SHALL BE AS CLOSE TO WALLS 4 ROOF DECK AS POSSIBLE 20) PROVIDE ALL TRANSITIONS AS REQUIRED FROM MAIN DUCT OR BRANCHES TO DIFFUSERS OR REGISTERS OR GRILLES. PROVIDE MANUAL VOLUME DAMPERS AT ALL BRANCHES TO EACH DIFFUSER NEAR MAIN TRUNK. WITH ACCESS_ REFER TO DETAIL 2 ON SHEET M -1. 21) THE MECHANICAL CONTRACTOR SHALL REVIEW ALL OTHER DRAWINGS (ARCHITECTURAL PLUMBING AND ELECTRICAL) AND SPECIFICATIONS CONTAINED IN THE CONSTRUCTION DOCUMENTS FOR ITEMS TO BE INCLUDED IN HIS WORK WHICH MAY NOT BE SPECIFICALLY SHOWN HERE ON THE MECHANICAL DRAWINGS. UNDER NO CIRCUMSTANCES SHALL ADITIONAL COMPENSATION BE DUE THE MECHANICAL CONTRACTOR FOR WORK SHOUJN IN OTHER LOCATIONS OF THE CONSTRUCTION DOCUMENTS WHICH WAS NOT SUBMITTED WITH THE ORIGINAL BID. A 22) HORIZONTAL DUCT SUPPORTING MEANS AND SPACING PER 2006 INTERNATIONAL MECHANICAL CODE/ SMACNA. EXHAUST FAN SCHEDULE SYMBOL MARK MAKE & MODEL NO CFM S.P. RPM HP VOLTAGE /PH AREA SERVED ROOF OPENING WEIGHT NOTES Ark CAPTIVE AIRE . NCA14FA 1,300 0.9" 1,066 1/2 208V, 3 PH HOOD # 1 20 "x20" 140 LBS. 2,625 MI (5) RANGES, (1) OVEN SUPPLY DIFFUSER (SD.), (ARROW SHOWS DIRECTION OF FLOW). RETURN GRILLE (RG.), OR RETURN REGISTER (RR.) CAPTIVE AIRE NCA16FA 4,250 �"ti- 1:0" ✓�•�'u 1,350 2.0 208V, 3 PH HOOD # "2 &7 24 "x24" 190 LBS. D Q 1 MANUAL VOLUME DAMPER (M.V.D.) 0 SMOKE/FIRE DAMPER (S.F.D.), SMOKE DAMPER: ACOUSTICALLY LINED DUCT, SIZE IS NET OPENING. ® » 6'-6" 1.0" 1,191 1.5 208V, 3 PH HOOD # 3 24 "x24" 190 LBS. Y CAPTIVE AIRE NCA16FA 3 600 VW 0 1 MININUM 1" UNDER CUT e CAPTIVE AIRE NCA14FA 1,300 0.9" 1,066 1/2 115V, 1 PH HOOD # 4 20 "x20" 140 LBS. RPM 0 VOLTAGE /PH ® GREENHECK GB- 300 -LMDX 7,100 1.0" 800 3 208V, 3 PH SALES AREA 32.5 "x32.5" 0.333 115V, 1 PH Q 23 "x23" GREENHECK SP- 8110 -QD 110 .25" 950 1/12 120V, ,1 PH VALERIO'S TOILET 6" DIA. 30 LBS. 208V, 3 PH ® 32.5 "x32.5" 275 LBS. © GREENHECK GB -071 400 0.5" 1,247 1/4 120V, 1 PH MARKET TOILET 14.5 "x14.5" HOOD # 3 32.5 "x32.5" Q 15.4 ® GREENHECK CSP -B150 148 .25" 0.5" 1/8 120V, 1 PH OFFICE 7 ,, DIA. 23 "x23" 184 LBS. 0 0 ® GREENHECK SP- B110 -QD 110 .25" 950 1/12 120V, 1 PH PHARMACY TOILET 6" DIA_ 30 LBS. 0 EF CAPTIVE AIRE NCA10FA 1,350 „ 0.5 1,112 0.333 120V, 1 PH HOOD 5 16 "x16" 120 LBS. ( 10 ® GREENHECK CUBE- 098 -4G -QD 450 0.5" 1,500 1/4 120V, 1 PH HOOD # 6 14.5 "x14.5" 75 LBS: ® ® CONTROL W/ 120V INLINE THERMOSTAT REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. GOOSENECK Is G.A. SHT. METAL 1/2" MESH NO. IS GA. GALV. BIRD SCREEN IN REMOVABLE FRAME. r DOUBLE. THICK 6' BASE LAG ,4X SCREWS UJ/ WASHER TO BASE 6" ON CENTER NAIL COLLAR ON 6" O.C. 4 MASTIC. S x 12 DUCT, SEE PLAN FOR CONSTRUCTION TURNING VANES 1" x 1" SHT. METAL ANGLE SOLDER TO BOTTOM OF GOOSENECK RIVET FLASHING COLLAR TO GOOSENECK 4 CONTINOUS SOLDER ROOF SPLIT FLASHING COLLAR 20 GA. G.I. RIVET 4 SOLDER IN PLACE GOOSE NECK DETAIL SCALE: NONE SEPARATE PERMIT REQUIRED FOR: 0 Mechanical tit Electrical Plumbing lig Gas Piping City of Tukwila BUILDING DIVISION MECHANICAL LEGEND AND ABBREVIATION SYMBOL MARK NEW DUCTWORK UJ/ SIZE INDICATED EXHAUST CFM u_ ; EXISTING DUCTWORK TO REMAIN S.P. APPLIANCE UNDER HOOD EXHAUST DUCT EQUIPMENT ON ROOF SHOWN ON PLAN ..: - ' REVIEWED MANCE APPROVED JUN 2 4 2010 City of kwila BUILDING !VISION 6'-6" 1,300 11111111 FLEXIBLE DUCT . SECTION THRU RECTANGULAR SUPPLY DUCT. SECTION THRU RECTANGULAR RETURN DUCT. SECTION THRU RECTANGULAR EXHAUST DUCT. ` = - CAPTIVE AIRE 4824 -ND -2 -PSP -F VW STANDARD 96HV ® �-- 3,500 2,625 - (5) RANGES, (1) OVEN SUPPLY DIFFUSER (SD.), (ARROW SHOWS DIRECTION OF FLOW). RETURN GRILLE (RG.), OR RETURN REGISTER (RR.) CAPTIVE AIRE 5424 -ND -2 -PSP -F ®m MIL ® 12' -8" 3,600 2,700 0.525 {3) FRYER, (2) GRIDDLE, (1) RICE COOKER D CAPTIVE AIRE 4824 -ND -2- PSP -F 1 MANUAL VOLUME DAMPER (M.V.D.) 0 SMOKE/FIRE DAMPER (S.F.D.), SMOKE DAMPER: ACOUSTICALLY LINED DUCT, SIZE IS NET OPENING. 60 © » 6'-6" S T 0 0 MO O (L) DL. VL. S,4 R4 EXH EF CONT CFM ABy BOD CLG OPN'G LL. TV. U/C SD. FC. TG. MUA. UTR. DIA. ® DIRECTION OF MIN. 1/4" PER FOOT SLOPE OF GREASE DUCT THERMOSTAT - INSTALL 4 ABOVE FINISH FLOOR SENSOR BY MECH. CONTRACTOR BY ELEC. CONTRACTOR LINED DUCT DOOR LOUVER VERIFY LOCATION AT FIELD SUPPLY "AIR RETURN AIR EXHAUST EXHAUST FAN CONTINUATION CUBIC FEET MINUTE B EE PER M NU E Ai3OVE BACK DRAFT DAMPER CEILING OPENING No. (3) FRYER O J\f\W 1) \\ POINT OF CONNECTION P E CTION Plan review Q LANDLORD approval is subject errors and omissions, TURNING VANES Approval of construction documents does not authorize " the violation of any MINIMUM 1 DOOR UNDERCUT Y Opt code or ordinance. Receipt of approved Field Co conditions d SMOKE DETECTOR P Copy 1S acknowledged: FLEXIBLE CONNECTION Y TRANSFER GRILLE _ MAKE UP ,41R D a' il C 0 _ UP THROUGH ROOT= DIAMETER City Of Tukwila BUILDING SI 0 1 MININUM 1" UNDER CUT 14"x8" CAPTIVE AIRE 4224 -VHB -G 2 16X16 11 DOOR LOUVER ® SUPPLY FAN SCHEDULE SMAROL MAKE & MODEL NO CFM S.P. RPM HP VOLTAGE /PH AREA SERVED ROOF OPENING WEIGHT NOTES © CAPTIVE AIRE NSAU1 -G10 1,105 0.5" 697 0.333 115V, 1 PH HOOD # 1 23 "x23" 184 LBS. YORK AHP48D Q © CAPTIVE AIRE NSAU2 -G12 2,625 0.5" 663 0.750 208V, 3 PH HOOD 2 # 32.5 "x32.5" 275 LBS. 179 LBS. ® 0 CAPTIVE AIRE NSAU2 -G12 2,700 0.5" 669 0.750 208V, 3 PH HOOD # 3 32.5 "x32.5" 275 LBS. 15.4 © ® CAPTIVE AIRE NSAU1 -G10 1,105 0.5" 697 0.333 115V, 1 PH HOOD # 4 23 "x23" 184 LBS. 50 0 HOOD SCHEDULE SYMBOL MARK LENGTH EXHAUST CFM u_ ; MAKE `UP CFM S.P. APPLIANCE UNDER HOOD EXHAUST DUCT MAKE & MODEL ® 6'-6" 1,300 1,105 0.370 (3) RANGES 12 x10 CAPTIVE AIRE 4824 -ND -2 -PSP -F VW STANDARD 96HV ® ,� 15'-6" 3,500 2,625 0.454 (5) RANGES, (1) OVEN 16„ x16 » CAPTIVE AIRE 5424 -ND -2 -PSP -F M MIL ® 12' -8" 3,600 2,700 0.525 {3) FRYER, (2) GRIDDLE, (1) RICE COOKER 16 "x16" CAPTIVE AIRE 4824 -ND -2- PSP -F © 60 © » 6'-6" 1,300 1,105 0.370 (3) FRYER O » „ 10 x12 CAPTIVE AIRE 4824 -ND -2 -PSP -F 0 STANDARD 36 ® » 91-0" 1,350 0 0.109 (1) OVEN 14"x8" CAPTIVE AIRE 4224 -VHB -G 0 230V./1 ® 3 -0 450 0 0.109 (1) STEAMER 12"x12" TYPE II CANOPY HOOD 36"36"x24" Q 80 67 3' -8 750 0 » 0.287" (1) ROTISSERIE „ 8X8 » CAPTIVE AIRE 36 "x24" ND -2 4HK6500506 179 LBS. NOTES: EACH HOOD AND RELATED EXHAUST FA`MMS AND MAKE -UP AIR UNITS ARE ELECTRICALLY INTERLOCKED. EACH HOOD IS EQUIPED WITH AN APPROVED ANSUL FIRE PROTECTION SYSTEM THAT WILL TURN OFF THE GAS VALVE TO ALL THE COOKING EQUIPMENT UNDER THE I-100P AND ENERGIZE THE ANSUL SYSTEM AT SAME TIME_ FLY FAN SCHEDULE MARK (ACF #) QTY MANUFACTURER MODEL # AIR FLOW CFM MOTER ELECTRICAL DATA APPROX. WEIGHT LBS. ACCESSORIES NOTES VOLT. 4 HZ. FOR EACH HP MOTOR QUANTITY UDAP -400 2 MARS STANDARD 96HV 8,000 120 1 60 1 2 225 MRS, T INSTALL WITH AUTOMATIC ON /OFF MICRO DOOR SWITCH MIL - - Arlik 1 MARS STANDARD 6.5'HV 5,100 120 1' 60 1/2 1 146 MRS, T INSTALL WITH AUTOMATIC ON /OFF MICRO DOOR SWITCH ® _ 1 MARS STANDARD 36 2,500 120 1 60 1/2 1 73 MRS, T INSTALL WITH AUTOMATIC ON /OFF MICRO DOOR SWITCH 230V./1 117 30 UNIT HEATER SCHEDULE MARK (ACF #) MANUFACTURER MODEL # HEATING ELECTRICAL TYPE INPUT (MBH) OUTPUT (MBH) EFF VOLTS /PH HP REMARKS °F db REZNOR UDAP -400 NG 400 332 83% 120/1 1/2 FIELD ADJUSTED FOR OPERATIONS AT SITE ELEVATION. 120/4 VOLT CONTROLS. AIL 15,000 1,500 AIR CONDITIONING AND FAN COIL SCHEDULE 1.D. TAG. MANUFACTURER ' & MODEL NO. NOMINAL TONNAGE COIL EAT AIRFLOW ;- (CFM) O.A. (CFM) EXT.S.P (IN. W.C.) VOLTS/ PHASE UNIT TOTAL HEATING WEIGHT REMARKS °F db °F wb MCA FUSE CAPACITY (KW) MODEL K EAC) EXISTING TRANE SFHC -C304 30 80 67 15,000 1,500 2.0 460V./3 - - - _ _ EXNG UNIT FLA = 75 1=4c EXISTING TRANE SFHC -C304 30 80 67 15,000 1,500 2.0 460V./3 - - _ _ _ EXISTING UNIT FLA = 75 C z > (F) YORK AHP36C 3 80 67 1,200 120 0.4 230V./1 29.5 30 4.8 4HK6500506 159 LBS. YORK 1 YZB02411 YORK AHP48D 4 80 67 1,600 160 0.4 230V./1 29.8 30 4.8 4HK6500506 179 LBS. RECEIVEC KArk T) 2 YORK AHP48D 4 80 67 1,600 160 0.4 230V./1 29.8 30 4.8 4HK6501006 179 LBS. GIfYOF1UKV1 SUN 0 $ 2C PERMIT CE ® Fc YORK AHP18B 1.5 80 67 600 50 0.4 230V./1 15.4 20 2.5 4HK6500206 125 LBS. YORK AHP18B 1.5 80 67 600 50 0.4 230V./1 15.4 20 2.5 4HK6500206 125 LBS. T) ( 5 SPLIT SYSTEM HEAT -PUMP SCHED ' T V-16110 \‘' CoM UNIT NUMBER MAKE / MODEL " NOMINAL CAPACITY (TON) COOLING CAPACITY BTUH HEATING CAPACITY BTUH ELECTRICAL DATA T TOTAL WT. -- NOTES VOLT. PH. HZ MCA MOCP SEER FLA AM YORK / THGD36 3 36,000 28,000 208 3 60 12.9 Z0 13 106 220 LOCATED ON ROOF ON STRUCTURAL MEMBER An YORK 1 THGD48 4 48,000 34,000 20S 3 60 153 15 13 125 250 LOCATED ON ROOF ON STRUCTURAL MEMBER v An YORK / TI -IGD48 4 48,000 34,000 20S 3 60 12 15 13 125 250 LOCATED ON RCCF ON STRUCTURAL MEMBER Q YORK 1 YZB02411 2 24,000 20,000 20S 1 60 18.8 30 14 15_2 250 LOCATED ON ROOF ON STRUCTURAL MEMBER (ID) ( 4 rk YORK 1 YZB02411 2 24,000 20 ,000 208 1 60 186 30 14 152 250 LOCATED ON ROOF ON STRUCTURAL MEMBER LA 10 E ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSITRJE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHT: NADEL RETAIL ARCHITECTS, UP. ALL RIGHTS RESERVED. H.D. SUBMITTAL: 01.04 -10 B.D. SUBMITTAL: 01 -21 -10 2nd H.D. SUBMITTAL 02.08 -10 BID SET 02-09.10 3rd H.D. & 2nd B.D. SUBMITTAL 03-01 -10 3rd B.D. SUBMITTAL: 03-24 -10 CONSTRUCTION SET: 04-12-10 NODEL RETHIL Nadel Studio One, Inc. 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F. 310.826.0182 www.nadelarc.com E TNE8 09/21/2010 -J z 0 0 -J RE1A81GN& A BULLETIN #6 /�D"• -•,n10 LA i Q A A A DATE 02.09.10 JOB NO. 09293 SHEET NUMBER -1 GROCERY 'vEVAREHOUSE -SD-5 800 CFM UNLOADING -REVIEWED Ft5r1 - CODE COMPLIANCE APPROVED JUN 2 4 2010 City of Tukwila BUILDING DIVISION Nadel Studio One, Inc. 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F. 310.826.0182 www.nadelarc.com SD-5 800 CFM r— E G —1 100 CFM (TYF. 4) Fl S — COOL R15= ROOM 10”)(10” DUCT UP TO ROOF TO: GOOSE NECK COVER OPENING WITH 1/2'' GALVANIZED STEEL WIRE .MESH. SD-5 800 CFM 20”x14"\- T CORA ;TORAG, '>OFFI.CE -SD-1 100 CFM RG-2 440 CFM L12'-'*121' DUCT UP TO :, ROOF TO GOOSE NECK COVER OPENING WITH 1--- GALVANIZED STEEL I WIRE MESH. 0 CFM 400 CFM (TYP. PRODUC COO_IR S—OPPING, CART CORA I SD-3 — 350 CFM RG-H 21 1.4401 CFM: N GREASE DUCT SCI—IEDULE DESIG- NATION EXHAUST AIIR CFM DUCT SIZE DUCT AREA DUCT VELOCITY PRESS DROP PER 100 L F EQUIV LENGTH DUCT LOSS HOOD LOSS SYSTEM LOSS ® ® © 0 150 SxS 5062.5FT00 1,500 FPM 0.45" UJG 10 FT 0.315" UJG 0281" UJG 0.315 + 0281 = 0.602" WG EQUAL 1,150 10)(14 0.912 SQ FT 1,S00 FPM 0A5"1.11G 33 FT e7.148" LIZ 0.454" LUG 0.148 . ex454 0.602" U. EQUAL 1,150 10x14 662 FT 1,500 FPM 0.45" 1.1.-G 33 FT 0.14S" ILG 0.454" LUS �.148 + 0.454 = 0.602" 11,G 4250 16xI6 1_111 sG2 FT 2,3S1 FPM 0.50" 30 FT �l�" wG N/A 0.150 + 0..602 = 0.152" UJG NOTE SELECT FAN FOR SYSTEM EXHAUST RATE OF 4250 CFM AT 015 " I.LM ESP R•Oc4F- LADDER 14"x142—/ 12"x14"- SD-2 195 CFM NORTH REVISIONS: 0 A BLDG.& SAFETY BULLETIN #70 COMMENTS L7 05/28/2010 A BLDG. & SAFETY COMMENTS A BULLETIN #3 04/09/2010 A A 04/20/2010 / \ BULLETIN #4 A A 04/28/2010 BULLETIN #5 A A BULLETIN #6 / \ 05114/2010 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED VVORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPUCATED. USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF IHE ARCHITECT. COPYRIGHT: NAGEL RETAIL ARCHrrECTS, LIP. AIL BMWS RESERVED- H.D. SUBMITTAL 01-04-10 B.D. SUBMITTAL: 01-21-10 2nd H.D. SUI3MITTAL: M-09-10 BID SET: 02-09-10 3rd H.D. & 2nd B.D. SUBMITTAL 03-01-10 3rd B.D. SUBMITTAL 03-24-10 CONSTRUCTION SET: 04-12-10 REVISIONS No changes shall be made to the scope of work without prior approval of Tukvvila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Girbectrical E?rinumbing EiKas Piping City of Tukwila BUILDING DIVISION Nadel Studio One, Inc. 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F. 310.826•0182 www.nadelarc.com 4305 GISTERED • CHITECT ERBERT N. NADEL STATE OF WASHINGTON co ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHT: NADEL RETAIL ARCHITECTS, LLP. ALL RIGHTS RESERVED. H.D. SUBMITTAL: 01-04-10 B.D. SUBMITTAL: 01-21-10 2nd H.D. SUBMITTAL: 02-08-10 3rd H.D. & 2nd B.D. SUBMITTAL: 03-01-10 REVISIONS: A BLDG. & SAFETYA \ COMMENTS / DATE 02-09-10 JOB NO. 09293 SHEET NUMBER 7 r 1 1 1 L cp 1 i FILE COPY Permft No.., M 10: 1 Plan review appm vat is subject i T - ff001: e end salons. omi Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field p d *# i ous is admowledged: \Al i L BDate: 1.1.--C-City&-Ofr '9 ('uicwila ( BUILDING D ION ( M ) M ,/./2 _ * (CONSULTANT UNDER CONTRACT INITH OINNER) APPLICANT: CONSULTANT.: 0 Vy 1= IRA A STRUCTURAL ENGINEER: ELECTRICAL ENGINEER: MECH $ FLUM5. ENGINEER: 115) g JE)I 1 0 0 SUITE #130 ANF HALL1S ENGINEERING, M8SE- °1420 TELSTAR AVE., SUITE 11E3 5410 INILSHIRE BLVD., *0602 51552 VIA COLIMA, UNIT *112 EMRWtiV(0)11:1 El=ff10 EL MONTE, C.A. °I1151 LOS ANGELES, A. 00056 WESTLAKE VILLAGE, CA. q1562 (PHARMAGITY) REFERENCE PERMIT 4*: BLDG. $ SAFETY - 1210-023 MECHANICAL - - - MI0-011 PLUMBING - - - - PG10-001 ELECTRICAL - EL I 0-0051 (626) 448-5182 (525) (455-1065 (515) 755-5551 (626) 445-50012 FAX (515) -155-5554 FAX 1, (9 ATTN: LEN FINER G ATTN: BILL BOOTH (PLUMB) ,--i 11127r, ED ATTN: MICHAEL WANG _-v 0 ATTN: TOM NASROLLAHI (MECH.) E00) caD EgE=0)ErC--3Thi(°) P L, >X< ER cr5,,c-EDI EMEE=C-Jc9g0f1 a315) 545-1556 (as) 54a-ow FAx I- -171Rrila V ri___, A (O ,1J A A LEGEND VICINITY MAP SUMMARY APPLICABLE CODES GENERAL NOTES SFC GENERAL NOTES SHEET INDEX e KEYNOTE REFERENCE GRID NUMBER 40 NUMBER INTERIOR ELEVATION BUILDING WALL 2 DIRECTION OF WALLS Oj ODUE .s. EXISTING TWO STORY BUILDING p ALL INORK SHALL COMPLY INITH THE FOLLOWING CODES INCLUDING INASHINGTON STATE AMENDMENTS 1. 2006 INTERNATIONAL BUILDING CODE 2. 2006 INTERNATIONAL BUILDING CODE CHAPTER 1 icG/ANSI A111.1 (2005), ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 5. 2006 Its1TERNATIONAL MECHANICAL CODE 4. 2006 INTERNATIONAL FIRE CODE • 2006 UNIFORM PLUMBING CODE 6. 2006 WASHINGTON STATE ENERGY CODE 1. 2006 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE 5. 2005 NATIONAL ELECTRICAL CODE (NFPA 10) cf. 2006 INTERNATIONAL FUEL 4 GAS CODE . ALL INORK , MATERIALS, METHODS, ETC., SHALL CONFORM TO ALL GOVERNING BUILDING CODES, ORDINANCES, REGULATIONS AND AGENCIES. 2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND CONDITIONS THEREON BEFORE COMMENCING THE INORK. REPORT ANY DISCREPANCIES AND / OR POTENTIAL PROBLEMS TO THE ARCHITECT, PRIOR TO PROCEEDING. 5. GOVERNING CODES AND FIRE DEF'ARTMENT FIELD INSPECTORS SHALL DICTATE SIZE, TYPE, QUANTITY AND LOCATIONS OF BOTH 'TEMPORARY AND PERMANENT PORTABLE FIRE EXTINGUISHERS. (N.I.C) 4. THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS ( OR ACCESS DOORS ) AS REQUIRED I5Y GOVERNING AGENCIES FOR AIR CONDITIONING, PLUMBING FIRE SPRINKLER AND ELECTRICAL SYSTEMS. PROVIDE APPROVED ASSEMBLIES WITH SELF - CLOSING DEVICES IN ONE (I) HOUR RATED CONSTRUCTION. 5. ALL PENETRATIONS AT FIRE RESISTIVE CONSTRUCTION SHALL E3E PROTECTED INITH APPROVED FIRE ASSEMBLIES. LAR ROTECTION BA RRICADES, 6. PROVIDE PEDESTRIAN OR VEHICU I= TEMPORARY GUARD RAILS, AND/ OR CANOPIES AS REQUIRED BY THE LOCAL AUTHORITIES OR AS NECESSARY FOR PEDESTRIAN AND VEHICULAR SAFETY. 1. EXIT SIGNS, INHERE NOT OR REQUIRED SHALL BE WORDED "EXIT" IN LETTERS HA■VING THE PRINCIPAL STROKE OF NOT LESS THAN 5/4" WIDE AND AT LEAST 6" HIGH AND SHALL CONFORM TO CODES AND / OR APPLICABLE REGULATIONS. 5. TACTILE EXIT SIGN SHALL BE PROVIDED AT ALL EXIT DOORS, EXIT STAIRS, EXIT RAMPS AND EXIT ROUTES AS REQUIRED BY THE CALIFORNIA BUILDING CODE. q. EVERY EXIT DOOR SHALL BE OPENABLE FROM THE NSIDE INITHOUT THE USE OF A KEY OR ANY SPECIAL KNOINLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYI°E. FLUSH 5oLTS oR SURFACE BOLTS ARE PROHIBITED. 0. PROVIDE A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT To THE DOOR STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS" IN LETTERS, NOT LESS THAN I INCH HIGH ON A CONTRASTING BACKGROUND AT ALL. REQUIRED EXIT pOORS. . EXIT DOORS SHALL. OPEN OVER A LANDING NOT MORE THAN 1/2" BELOIN THE THRESHOLD. ONDUITSPLUMSING NES, 2. ALL EXPOSED ELECTRICAL EQUIPMENT, C LI ETC... SHALL BE PAINTED WITH MIN.(2) COATS OF PAINT TO MATCH T1-4E ADJACENT SURFACES. 15. CONTRACTOR SHALL COORDINATE ALL SLEEVING FOR IRRIGATION LINES AND CONDUITS UNDER SIDEWALKS, DRIVEWAYS, ETC., PRIOR TO POURING CONCRETE OR LAYING ASPHALT PAVING. 14. THE GENERAL CONTRACTOR SHALL. PROVIDE AND INSTALL THE ADDRESS AND / OR SUITE UNIT NUMBERS PER CITY AND FIRE DEPT. REQUIREMENTS. VERIFY SIZE, COLOR AND LOCATIONS, PRIOR TO PROCEEDING. 15. OBTAIN TENANT'S LATEST CRITERIA DRAWINGS AND / OR TENANT'S CONTRACTOR DRAWINGS FOR EXACT LOCATION OF ALL PLUMBING, MECHANICAL AND ELECTRICAL ROUGH-IN, STUB-UPS, ETC. THE GENRAL CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL FROM TENANT'S REP RESENTATIVE, PRIOR TO POURING CONCRETE FLOOR SLAB OR APPLING FINISHES ON WALLS. 16. THE GENERAL CONTRACTOR SHALL FURNISH A HYDRAULICALLY CALCULATED AUTOMATIC FIRE SPRINKLER SYSTEM. CONTRACTOR SHALL PREPARE SHOP DRAINING5 AND OBTAIN APPROVALS FROM THE INSURANCE SERVICE OFFICE (150) WHEN REQUIRED BY OINNER, BUILDING / FIRE DEPARTMENT AND OTHER REQUIRED GOVERNING AGENCIES PRIOR TO SUBMITTAL TO THE ARCHITECT FOR APPROVAL, PRIOR TO INSTALLATION. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR A COMPLETE SYSTEM FROM CONNECTION OF SITE WATER MAIN TO INTERIOR OF 5UILDING. 17• &ENERAL CONTRACTOR TO CLEAN UP AND REMOVE ALL REFUSE MATERIALS, CONDUIT, WIRES, ETC... AT END OF EACH SHIFT. 1. BIDDERS (GENERAL CONTRACTORS AND SHALL THOROUGHLY FAMILIARIZE THEMSELVES ARCHITECT'S DRAWINGS AND SHALL NOTIFY ANY DISCREPANCY, OMMISSION, CLARIFICATION, INFORMATION NECESSARY FOR THE COMPLETION INORK. 2. ALL TRADES SHALL FURNISH ALL LABOR, SERVICES REQUIRED TO PERFORM ALL INDICATED OR RESONABLY INFERRED APPLICABLE COS E TO COMPLETE THEIR A COMPLETE AND PROPER FINISHED JOB. 5. CONTRACTOR PRIOR TO BIDDING SHALL. APPLICABLE DRAWINGS AVAILABLE TO ENSURE THAT THEY HAVE INCLUDED ALL COMPLETE THEIR WORK. THE GENERAL SHALL BE DEEMED COMPLETE AND REPRESENTING CONSTRUCTION DRAWINGS AND PROJECT 4. ANY CONTRACTOR PRIOR TO INSTALLATION OF MATERIALS SHALL NOTIFY THE AIRCHITECT IF ANY. FAILURE TO O 50 SHALL MEAN D CORRECTIVE MEASURES SHALL BE DONE CONTRACTOR AT HIS OINN EXPENSE AND THE PROJECT SCHEDULE. 5. THE INTENTION OF THE CONSTRUCTION INCLUDE ALL LABOR, MATERIALS, EQUIPMENT TRASNSPORTATION NECESSARY FOR COMPLETE EXECUTION OF THE WORK. 6 EXISTING SUILL,ING FEATURES/CONDITIONS SLAB UTILITIES OR STRUCTURE) INERE SHOWN DRAWINGS PROVIDED BY LANDLORD (WESTFIELD) TAKEN TO REFLECT THESE EXISTING CONDITIONS. TO VERIFY EXISTING CONDITIONS PRIOR WORK. 1. INHERE NO CONSTRUCTION DETAILS ARE ANY PART oF THE INORK, SUCH DETAILS A5 FOR SIMILAR WORK SHOWN ON THE SHALL CONFORM TO ACCEPTED STANDARDS 5. INHEN SHoF DRAWINGS ARE REWIRED, TO SE VERIFIED AT THE JOB SITE BYN CONTRACTOR PRIOR TO FABRICATION '1 • IAIORK NOT INCLUDED IN CONTRACT WILL "NIG", "FUTURE" OR "BY °INNER" AND MAY THE CONSTRUCTION CONTRACT. ALL OTHER BY THESE CONTRACT DOCUMENTS SHALL RESPONSIBILITY OF THE CONTRACTOR INCLUDED IN THE E3ID PRICE. 10. CONTRACTOR SHALL PROVIDE ANY AND BRACING NECESSARY TO ENSURE THE ALL PARTS OF THE PROJECT DURING CONSTRUCTION. II. SIGNAGE SHALL BE CONTRACTED DIRECTLY THE GENERAL CONTRACTOR SHALL PROVIDE ACCESS PANELS AND NECESSARY BLOCKING OF SIGNS. CONTRACTOR 15 RESPONSIBLE WITH OWNER'S SIGN CONTRACTOR. SUB-CONTRACTORS) INITH THE ARCHITECT OF ETC. OF ANY OF THEIR EQUIPMENT, AND WORK NECESSARY, OR REQUIRED BY ANY SCOPE OF WORK FOR MAKE ALL. ALL SUB-BIDDERS TO ITEMS NECESSARY TO CONTRACTOR'S BID THE SPECIFICATIONS. OR PROCUREMENT OF PROBLEMS, THAT ALL NECESSARY BY THAT WITHOUT IMPACT TO DOCUMENTS 15 TO AND AND PROPER (INCLUDING UNDER FROM RECORD WHICH INERE CONTRACTOR TO PERFORMING HIS SHOWN OR NOTED FOR SHALL BE THE SAME DRAININGS AND/OR OF PRAGTIGE. ALL DNIENSIONS ARE THE GENERAL OF THE ITEM. BE DESIGNATED AS BE EXCLUDED FROM INORK REQUIRED BE THE D B AN SHALL E ALL. SHORING AND STABILITY OF ANY AND BY THE °INNER. J-BOXES, FOR FASTENING FOR COORDINATION REVIEWED FOR CODE cOMPLIANCE APPROVED MAR 2 2 2010 -3-- . City of Tukwila BUILDING DIVISION i ARCH 1 TECTURAL. CONSTRUCTION TYPE 15 rfp! 11-V FULLY SPRINKLERED T-1 .0 TI TL! SHEET AR-I.0 OVERALL REFERENCE SITE PLAN AR-1.1 ENLARGED REFERENCE SITE PLAN AR-1 .2 Si T! UTILITY PLAN A-0.0 OVERALL REFERENCE FLOOR PLAN DA-I .0 DEMOL I TI ON PLAN A-I.0 FLOOR PLAN OCCUPANT LOAD ANALYSIS Min. 3 1 means of! I egress 1 Reci'd Occupan when I Egress Egress 4 Est SF Load of Total # of Occ Width Provided Occupants e Suite # Description SF Breakdown Factor Occupants exceeds Inches Inches .0 SECTION WALL NUMBER - • • A-I.2 ENLARGED FLOOR PLANS, ELEVATIONS $ DETAILS A PLAN CHANGE/BULLETIN EXTERIOR MATERIAL COLOR REFERENCE IV r r K . ...., .5 ADDENDUM 0 DOOR REFERENCE NUMBER • 0 < 111 V V < °- A-I.5 SUITE 150 ENLARGED PLANS TuKlAnLA )- , FARKAAT I- kl) Lu K V ix SAKER CIO ISFC Market - Occup. Group M 30,427 ' 681 5001 - • tLOOR S • ,-- Sales 19,750; 30i 658.31 1 , 98.8 K L <rf a_ V iu 1_ For fir - .., A-5.0 ROOF PLAN 6.0 DETAIL REFERENCE Kitchen 1 0991 2001 5.51 , / 0. - Warehouse/Storage 6 412 5001 12.81 , 1 1.9 • ...., ..., A-4.2 SUITE 150 140 4 0 INTERIOR ELEVATIONS , 15 0 3.0 Locker Room 15i1 i 1._ -..- B < LVD o... V ABBREVIATIONS -". -SC A-6.0 MISCELLANEOUS DETAILS Office 11 1001 1 10 ' 120 /Re a I Occup. Group M 163 301 .4 5.4 501 0,8 501 0.9 I 50 6.5 501 11.81 A-1.0 DOOR $ ROOM FINISH SCHEDULE STRUCTURAL: Z ILI 0 ILI > 0 A/C AIR CONDITIONING M.H. MANHOLE A.C. ASPHALTIC CONCRETE M.O. MASONRY OPENING A.F.F. ABOVE FINISH FLOOR MTR. METER ALUM. ALUMINUM N.I.C. NOT IN CONTRACT A.S.R. AUTOMATIC SPRINKLE RISE N.T.S. NOT TO SCALE BLK. BLOCK 0/ OVER BLDG. BUILDING 0.C. ON CENTER 0.D. OVERFLOIN DRAIN C.B. CATCH BASIN O.S. OVERFLOW SCUPPER C....I. CONTROL. JOINT °Fp. oPposITE C.L. CENTER LINE CLG• CE I L 1 NG PL. PROI°EIRTY LINE c• L. GLEAR P.o.G. POINT OF CONNECTION COL. COLUMN CONC. CONCRETE R.D. ROOF DRAIN CONT. CONTINUOUS SIM. SIMILAR C.T. CERAMIC TILE T.C. TOP OF CONCRETE D.5. DOM SPOUT T.M. TOP OF MASONRY E.D.F. ELECTRIC DRINKING FOUNTAIN T.P. TOP OF PARAPET E. J. EXPANSION JOINT T.5. TOP OF SHEATHING E.IN.C• ELECTRIC INATER COOLER TIP. TYPICAL EXP. EXPOSED U.N.O. UNLESS NOTED OTHERWISE F.D. FLOOR DRAIN Ai INITH F.G. FINISH GRADE W.H. INATER HEATER F•H. FIRE HYDRANT INTR. WATER FIN. FINISH V.I.F. VERIFY IN FIELD FL. FLOOR F•O.C. FACE OF CONCRETE F FAcE OF MASONRY F.0.5. FACE OF 5TUD F.5. FINISH SURFACE / FLOOR SINK 6•1• GALVANIZED IRON Retail - OCCUP. Group M 185 30 6.2 6.21 t STRANDER I3LV17. 0 (f) 9 30 40 Retail (Pharmacity) - Occup. Group M 1,301 30 43.41 43.41 Food (Plhoy Kitchen) - Ocbilp. GrouP A-2 2,354 78.4 STO GENERAL NOTES STI FOUNDATION DETAIL5 ST2 ROOF FRAMING DETAILS $ MISCELLANEOUS DETAILS ST 5 MISCELLANEOUS DETAILS DI.0 DEMOLITION FOUNDATION PLAN D2.0 2ND FLOOR FRAMING PLAN 51.0 FOUNDATION PLAN 52.0 2ND FLOOR FRAMING PLAN Kithhen 1,2741 200 6A1 W ..b.. 0 Z NO SCALE 50 Customer/Seating Retail alerios Bakery) - Occup Group M . - .., , 1,080 151 72.0 3.4 ,506 22.71 50 , Kitchen! 9691 2 4,8 Sales 537 30, 17.91 FLUM-13ING FIXT - t- ' • PER TA'-4 20102.1 INA - A TIONS: ./ 7, TS 2006 1E30 ...; . 00 & LAM c S . 5..d -.4 ELEGTRI ,. 551 TOTAL 0:>,- PAN ( '. IA1 EN - MEN) Entry Vestibule 243 Utility Room 319, OCCUPANTS LAVToRIES (I PER '750) DRINKING FOUNTAIN (I PE R I,000) E-I SINGLE LINE DIAGRAM AND SYMsoLs LEGEND INA_ C_LO,..4.- • Toilet Roorns 206, p-o'E (I • - ' ) -2 LIHT!NC - 47, • pRoviDE O'D PROVIDED REGD. pRovver; Corridors 594 - - E-5 SUITE 150 ELECTRICAL PLANS Loading Dock 1,542 .., ...., ..., .., E-5 PANEL SCHEDULE MECHAM I CAL: To s 351936: 836.9 125.5 144 4101 MEN I + I URINAL. PROJECT ADDRESS SCOPE OF VVORK ........ ADDITIONAL NOTES M-I MECHANICAL SCHEDULE DETAILS AND NOTES , , M-2 MECHANICAL FLOOR PLAN M-5 MECHANICAL ROOF PLAN M-4 ENLARGED TENANT MECHANICAL FLOOR F'LAN M-5 CAPTIVEAIRE HOODS, EXHAUST FANS, AND MUA UNITS M-6 ENERGY FORMS FLUME3 I NG: 1565 SOUTHGENTER E3LVD. TUKIAll LA, lAIASHI NGTON i< I NG GOUNT'r AFN- cf202410010 BU I LD I NG: PUBLIC HEALTH - SEATTLE 4 KING COUNTY INSPECTION REQUIRED ON COMPLETION OF WORK PRIOR TO OPENING. L DEMOLITION OF REMAINING EXISTING INTERIOR IMPROVEMENTS (LANDLORD WILL DEMOLISH MAJORITY OF EXISTING IMPROVEMENTS IN THEIR SCOPE). DEMOLITION OF PORTIONS OF EXISTING FLOOR SLAB FOR FLOOR DRAINS, FLOOR SINKS AND TRENCH DRAINS. 2. NOT USED 5. 'TENANT IMPROVEMENTS OF PORTION OF GROUND FLOOR - (BALANCE OF GROUND FLOOR - 5,555 SF AND ENTIRE SECOND FLOOR TO BE IMF'ROVED UNDER SEPARATE PERMIT BY WESTFIELD. 4. NOT USED MECHAN I CAL : -G P0.I PLUMBIN COVER SHEET P-0.2 PLUMB 1 NG SCHEDULE -0. PLUMBIN TAILS P5 G DE P-I•0 WASTE AND VENT P-2.o HOT AND COW WATEIR P-.0 GAS LAN 5 , F.0.M. P-4.0 WASTE $ VENT ISOMETRIC \AEA RECEIVED MAR 1 0 2010 PERMIT CENTER ...4. CORRES1 ION LTR# I DIFFERED SUBMITTAL 5. INSTALLATION OF NEIN MECHANICAL VENTILATION SYSTEM (NE IN spur SYSTEM HEAT PUMP UNITS, EXHAUST FANS) AS INDICATED ON PLANS. • FIRE SPRINKLER FIRE ALARM • RAcK $ GONDOLA ANCHOR DETAILS FLUM51 NG : • INSTALLATION OF NEW PLUMBING FixTUREs AND PIPING (SANITARY INASTE, HOT $ COLD IAIATER AND GAS LINES) TO E TIE INTO XISTIN F'LUMBIN SYSTEM AS INDICATED ON PLANS. BD EG G M 10 0 1 ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHT: NADEL RETAIL ARCHITECTS, LLP. ALL RIGHTS RESERVED. H.D. SUBMITTAL: 01-04-10 B.D. SUBMITTAL: 01-21-10 2nd H.D. SUBMITTAL: 02-08-10 3rd H.D. & 2nd B.D. SUBMITTAL: 03-01-10 REVISIONS: A BLDG. & SAFETYA \ COMMENTS / DATE 02-09-10 JOB NO. 09293 SHEET NUMBER DOUBLE THICKNESS VANES LONG RADIUS ELBOW SQUARE ELBOW SUPPORT FROM STRUCTURE 0 MAX 4' -0" O.C. aPPRovED CLASS o OR GLASS 1 FLEXIBLE DUCT DIAMETER EQUAL TO DIFFUSER NECK SIZE (MAX. `` LENGTH 4' -0 ") SECURE WIN WORh1 DRIVE METAL GI_dMP SECURE WITH WoR I DRIVE METAL CLAM (TYPICAL) TYPICAL. CEILING DIFFUSER 11/2 MIN. 26 GA. RIGID DUCT WHERE BRANCH DUCT EXTENDS l'-0" AND LONGER BRANCH DUCT SPIN IN FITTING WITH HAND DAMPER AND LOCKING QUADRANT - LAY -IN CEILING - DIAGONAL WIRING BRACING SECURE TO STRUCTURE TYP. DIFFUSER CONNECTION DETAIL SCALE: NONE LEGEND NOTE: SHUNT ACROSS COMMON AND FAN TER1NAL TO ENSURE CONSTANT FAN OPERATION DURING TIME CLOCK 'ON' TIMES N ORDER TO DEACTIVATE 'AUTO' FAN MODE oN THERMOSTAT UL APPROVED SMOKE DETECTOR RETURN AIR DUCT WITH ACCESS. THERMOSTAT ON -OFF, 2 STAGE HEAT, 2 STAGE COOL, AUTO CHANGEOVER WITH SUBBASE AND COVER. (PROGRAMMABLE) W/ BUILT -IN TIME CLOCK SEE SCHEDULE PoR VOLTAGE DISCONNECT SWITCH. O - FACTORY SUPPLIED ECONOMIZER: AIR CONDITIONING UNIT. ®®©O®@®@ LOW VOLTAGE (TYP) OWIRING (GJ 00000@0@ CONDUIT PLUG (TYPICAL) UNION CONDENSATE TRA PER CODE FOR CONTINUATION SEE PLUMBING DRAWINGS 111 ECONOMIZER ACCESSORY HOOD. M -2 XI E ELE CONNECTIONS INSTALLED AEOVE ROOF. itardiar moms ip S.A. UNIT INSTALLATION DETAIL SCALE: NONE ACCESS HOLE 1/4" (6mm) DIA. ALL THREADED RODS. ACCESS COVER - 16 GAUGE INSULATION PINS WELDED FIRST LAYER THERMAL CERAMIC DUCT WRAP 16A CUT SAME SIZE AS COVER. GASKET NAILNG STRIP, FACTORY SUPPLIED SECOND /THIRD LAYER THERMAL CERAMIC D 15A WITH 1" (25mm) OVER LAP ON ALL SI SPEED ALUMINUN TAPE COVERING ALL EXPOSE SPOOL PIECES FOR THREADED RODS. 1/4" (6mm) DIA. WING NUTS. GREASE TIGHT GASKET RATED CLIPS PRE -FAB ROOF CURB BY MECH. CONT. AIR CONDITIONING UNIT BOLT (TYP) SHEET METAL STRAP COUNTER FLASHING PROVIDED BY MECHANICAL CONT. T ES. ROOF FELT 5Y GENERAL CONT. RIGID INSULATION OR PLYWOOD FILLER BY MECH. CONT. NOTE: FIREMASTER FASTWARP XL MUST B THE PRODUCT LISTING AND IN CO TERMAL CERAMICS PRODUCT D ROOF LNE FOR 1500'F MIN. 4" HIGH LEVEL PLATFORM 8Y GENERAL CONT. STALLED PER ALL SPECIFEC REQUIRMENTS OF CE WITH ERS -2213 FIGURE 2 AND ALL OTHER & INTALLATION GUIDE. THERMAL CERAMICS' FIRE WRAP ACCESS SUPPLY FAN MIN. DOOR DETAIL TYPICAL CEILING DIFFUSER 3"x16" 500 FPM ROOF MOUNTED CURB DETAIL - EXHAUST - TERMINATION - 10' -0" MIN. FROM ADJACENT SUILDINGADJACENT PROPERTY LINE, AIR INTAKES AND 10' -0" ABOVE ADJOINING GRADE LEVEL UL LISTED EXHAUST FAN WITH HINGED BASE, SET WITH DISCHARGE 40 INCH MINMUM ABOVE ROOF LINE PROTECT CORROSION OUTDOOR DUCTS AGAINST TRANSITIONING VENTILATED BASE FROM CURB TO FAN LE CONS ION, FOUR WAY BY GENERAL CONT'R. STEEL. ALL WELDED LIQUID t CONSTRUCTION GREASE EXHAUST GREASE DUCT 'DRAPED WITH APPROVED PIREMABTER FASTWRAP.1 -1R° THICKNESS CLEANOUt DOORS IN DUCTS D OR SEE DETAI ON SHEET 11-1 MAKE UP AIR RISER WITH VOLUME DAMPER TED CEILING STAINLESS STEEL PERFORATED PANEL EIL MIN. CLEARANCE OF 3" BETWEEN THE TYPE ONE HOOD AND ANY COMSLIBTISLE MATERIAL TYPICAL N ALL DIRECTIONS NOTE: 15% OF TOTAL MAKE -UP AIR WILL DIRECTLY SUPPLY TO THE 25% WILL SUPPLY TO THE KIT AND TOTAL MAKE -UP AIR EXHAUST AIR FROM IP S 3 AREA QUAL TO COOKING EQUIPMENT UL LISTED GREASE FILTERS SEE 48" MAX. 33° MIN. DISTANCE LE FOR SIZE AND QJANTIt' BETWEEN COOKING SURFACE AND T4-IE BOTTOM OF THE HOOD " MINIMUM OVERI4ANc BEYOND THE COOKING SURFACE ALL DIRECTIONS TYPICAL HOOD DETAIL SCALE: NONE DUCT MAY SE LINED, SEE PAIN FOR SIZE 4 LINING WHERE REQUIRED SET COUNTER - FLASHING N BEAD OF CAULKING 4 LAG TO CURB ROOF DECK TYPICAL ROOF OPENING,' 1" LARGER THAN DUCT SIZE. 11 POCKET LOCK SEAL W/MASTIC 2x6 CURB -CUT TO SLOPE OF ROOF- TOP FLAT. 25 "x25" CANT STRIP FLASH UP 4 COVER CURB W/ROOFNG GENERAL NOTES 1) TI-4E MECHANICAL; CONTRACTOR SHALL FURNISH ALL MATERIAL, LABOR, EQUIPMENT, APPURTENANCES, AND ALL CONTRACTUAL EXPENSES REQUIRED FOR THE COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM TO THE SATISFACTION OF THE OWNER, ARCHITECT AND MECHANICAL ENGINEER. 2) THE INSTALLATION SHALL COMPLY WITH 4 BE INSTALLED IN ACCORDANCE WITH ALL LEGALLY CONSTITUTED AUTHORITIES 4 CODES HAVING JURISDICTION. ALSO ALL THE REQUIREMENTS OF LANDLORD. 3) THE MECHANICAL CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, APPARATUS, ACCESSORIES (LE., THE ENTIRE INSTALLATION) AS FURNISHED BY 14IM FOR A PERIOD OF ONE YEAR 4) THE MECHANICAL CONTRACTOR SHALL OBTAIN 4 PAY FOR ALL PERMITS, LICENSES 4 INSPECTIONS REQUIRED TO COMPLETE THIS J05. 5) COORDINATE NE SIZE, LOCATION, SERVICE REQUIREMENTS OF ALL MECHANICAL EQUIPMENT 4 DUCTWORK WITH THE GENERAL, PLUMBING, ELEC CONTROL, 4 FIRE PROTECTION CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. REPORT ALL UNRESOLVED CONFLICTS TO THE ARCHITECT. 6) COORDINATE THE LOCATION OF ALL CEILING DIFFUSER, REGISTER, GRILLES 4 ETC. WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. -I) ALL SWEET METAL DUCTWORK SHALL BE NEW GALVANIZED SHEET METAL DUCT GAUGES, CONSTRUCTION SUPPORT, AND INSTALLATION 51-1ALL BE IN ACCORDANCE WITH THE 2001 CMC (64D4) ALSO REFER TO DETAIL 1 ON SHEET M -1 AND SMACNA. 8) ALL INSTALLATIONS MUST COMPLY WITH THE MANUFACTURER REQUIREMENTS INCLUDING THE OPERATION AND SERVICE CLEARANCE, PIPING, WIRING, ADJUSTMENTS AND ETC. 9) ALL TRANSVERSE JOINTS IN SUPPLY AIR DUCT SHALL SE SEALED AIR TIGHT WITH DAP CMC DUCT SEALER 10) FLEXIBLE CONNECTIONS SHALL SE PROVIDED FOR ALL DUCTWORK ATTACHED TO AIR MOVING EQUIPMENT MOUNTED ON OR SUSPENDED FROM VI3RATION ISOLATORS. FLEXIBLE CONNECTIONS SHALL SE CODE APPROVED NEOPRENE COATED GLASS TYPE FABRIC. WRAP INSULATION ON ALL NEW SUPPLY ELE TIC •, AND PLUMBI G CONTRA • 1-1 • -- •VU FLEXIBLE CONNECTIONS AT ALL MECHANICAL EQUIPMENT MOUNTED ON VIBRATION ISOLATORS` AND OR SUSPENDED' FROM VI5R4TION HANGERS. 13) PROVIDE TURNING VANES AT ALL 90° ELBOWS FOR SUPPLY AND RETURN DUCTS. CONTRACTOR TO PAY SPECIAL- ATTENTION TO WORKMANSHIP AND FABRICATION OF AIR DISTRIBUTION SYSTEM FOR MINIMUM STATIC PRESSURE. 14) PROVIDE ALL v •� 1 CTION. COMPLIANCE WITH SECTION 6063. SMOKE DETECTORS REQUIRED BY THIS SECTION SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 12. ACCESS TO SE PROVIDED FOR INSPECTION AND A° UPON ACTIVATION THE SMOKE DETECTORS SHALL SHUT DOWN ALL OPERATIONAL CAi °ABILITIES OF THE AIR DISTRIBUTION SYSTEM. SECTION 60s A.1. THE DUCT SMCKE DETECTORS MAINTANENCE. SECTION 606 SHALL 5E CONNECTED TO A FIRE ALARM SYSTEM. 15) PAI PLENUM B HIND EACH GR LE OR REGISTE' WIT LAT LAC PA 1 T. 16) 5ALANCE AND ADJUST ALL DIFFUSERS, REGISTERS, ETC. FOR OPTIMUM AIR DISTRIBUTION AND MINIMUM NOISE. SUBMIT A CERTIFIED AIR BALANCE REPORT TO THE MECHANICAL ENGINEER FOR APPROVAL. BALANCING OF TO THE SYSTEMS SHALL BE PERFORMED 5Y AN I NDE PENDE NT TE ST AND 54L ANGIN GAGE NCY WHICH SPECIALIZES IN THE SALANCING AND TESTING OF HEATING, VENTILATING AND AIR ALSO PROVIDE COPY OF THE TESTING AND BALANCING REPORT TO NE CITY INSPECTOR PRIOR TO FINAL INSPECTION. ONLY A QUALIFIED NE55 OR AASC SAL PERFORME THIS WORK ONING SYSTEMS. BUILDING AGENCY MUST 11) AS -BUILT RECORD PRINTS MUST SE PROVIDED PRIOR TO J08 COMPLETION. 1S) FLEXIBLE DUCT SHALL BE THERMAFLEX TYPE MKE, CLASS I, WITH 1" EXTERNAL INSULATION. MAX. LENGTH TO DIFFUSER 4' -0 ". NO FLEX. DUCT IN OPEN CEILING AREA, REFER TO DETAIL 2 ON SHEET M -1. 19) ALL DUCT WORK SHALL SE AS CLOSE TO WALLS 4 ROOF DECK AS POSSIBLE 20) PROVIDE ALL TRANSITIONS AS REQUIRED FROM MAIN DUCT OR BRANCHES TO DIFFUSERS OR REGISTERS OR GRILLES. PROVIDE MANUAL VOLUME DAMPERS AT ALL BRANCHES TO EACH DIFFUSER NEAR MAIN TRUNK WIN ACCESS. REFER TO DETAIL 2 ON SHEET M -L 21) THE MECHANICAL CONTRACTOR SHALL REVIEW ALL OTHER DRAWINGS (ARCHITECTURAL PLUMBING AND ELECTRICAL) AND SPECIFICATIONS CONTAINED IN THE CONSTRUCTION DOCUMENTS FOR ITEMS TO BE INCLUDED IN 1-115 WORK WHICH MAY NOT SE SPECIFICALLY SHOUJN HERE ON THE MECHANICAL DRAWINGS. UNDER NO CIRCUMSTANCES SHALL ADITIONAL COMPENSATION SE DUE THE MECHANICAL CONTRACTOR FOR WORK SHOWN IN OTHER LOCATIONS OF THE CONSTRUCTION DOCUMENTS WHI - WA OT SMI D TH T • GIN • SID 22) HORIZONTAL DUCT SUPPORTING MEANS AND SPACING PER EXHAUST FAN SCHEDULE SYMBOL MAKE & MODEL NO CFM S.P. RPM HP VOLTAGE /PH AREA SERVED ROOF OPENING WEIGHT NOTES ink. CAPTIVE AIRE NCAI4FA 1,300 0.9" 1,066 1/2 208V, 3 PH HOOD # 1 20 "x20" 140 LBS. 2,625 0 (5) RANGES, (1) OVEN ilk CAPTIVE AIRE NCAI6FA 3,500 1.0" 1,170 1.5 208V, 3 PH HOOD # 2 24 "x24" 190 LBS._ 16 "x16" 0 Q Ark CAPTIVE AIRE NCAI6FA 3,600 1.0 1,191 1.5 208V, 3 PH HOOD # 3 24"x24" 190 LBS. _ ® 9 -0 Ark CAPTIVE AIRE NCAI4FA 1,300 0.9 1,066 1/2 115V, 1 PH HOOD # 4 20 "x20" 140 LBS. 450 0 0.109 Arlik GREEN HECK GB- 300 -LMDX 7,100 1.0 800 3 208V, 3 PH SALES AREA 32.5 "x32.5" 160. 0.4 W 29.8 Ark GREENHECK SP- 8110 -QD 110 .25 950 1/12 120V, 1 PH VALERIO'S TOILET 6" DIA. 30 LBS. 67 1,600 160 0.4 GREENHECK GB -071 400 0.5" 1,247 1/4 120V, 1 PH MARKET TOILET 14.5 "x14.5" YORK AHP18B 1.5 80 Ark GREENHECK CSP -B150 148 p .25 1,050 1/8 120V, 1 PH OFFICE 7 " DIA. - 125 LBS. 0 0 GREEN HCK SP- B110-QD 110 .25" 950 1/12 120V, 1 PH PHARMACY TOILET 6" DIA. 30 LBS. 20 Q 4HK6500206 125 L: CAPTIVE AIRE NCAIOFA 1 350 0.5" 1 112 0.333 120V, 1 PH HOOD # 5 16"x16" 120 LBS. AM GREEN HECK CUBE- 098 -4G -QD 450 0.5" 1,500 1/4 120V, 1 PH HOOD # 6 14.5 "x14.5" 75 LBS. 0 CONTROL W/ 120V INLINE THERMOSTAT GOOSENECK 18 G.A. SI-IT. METAL 12° MESH NO. 16 G4 GALV. BIRD SCREEN N REMOVABLE FRAME. DOUBLE THICK BASE LAG SCREWS W/ WASHER TO BASE 6" ON CENTER NAIL COLLAR ON6 "O.C. 4 MASTIC. AX 8 x 12 DUCT, SEE PLAN FOR CONSTRUCTION TURNING VANES 1" x 1" 51-1T. METAL ANGLE SOWER TO BOTTOM OF GOOSENECK RIVET FLASHING COLLAR TO GOOSENECK 4 CONTNOUS SOLDER ROOF SPLIT FLASHING COLLAR 20 GA. G.I. RIVET 4 SOLDER N PLACE GOOSE NECK DETAIL SCALE: NONE MECHANICAL LEGEND AND ABBREVIATION NUM 0 0 (L) DL. VL. SA RA EXH _EF CONT CFM ASV SDD CLG OP•'G FOC LL. TV. u/C Sp. FC._ TG. MUA. UTR. DIA. NEW DUCTWORK W/ SIZE INDICATED EXISTING DUCTWORK TO REMAIN EQUIPMENT ON ROOF SHOWN ON PLAN FLEXIBLE DUCT SECTION THRU RECTANGULAR SUPPLY DUCT. SECTION THRU RECTANGULAR RETURN DUCT. SECTION THRU RECTANGULAR EXHAUST DUCT. SUPPLY DIFFUSER (SD.), (ARROW 51-1OW6 DIRECTION OF FLOW). RETURN GRILLE (BC.), OR RETURN REGISTER (RR) MANUAL VOLUME DAMPER (M.V.D.) SMOKE/FIRE DAMPER (S.F.D.), SMOKE DAMPER ACOUSTICALLY LINED DUCT, SIZE IS NET OPENING DIRECTION OF MIN. 1/4" PER FOOT 'SLOPE OF GREASE DUCT THERMOSTAT - INSTALL 4' ABOVE FINISH FLOOR SENSOR SY MECH. CONTRACTOR BY ELEC. CONTRACTOR LINED DUCT DOOR LOUVER VERIFY LOCATION AT FIELD SUPPLY AIR RETURN AIR EXHAUST EXHAUST FAN CONTINUATION CUBIC FEET PER MINUTE ABOVE SACK DRAFT DAMPER CEILING OPENING POINT OF CONNECTION LANDLORD TURNING VANES MINIMUM 1" DOOR UNDERCUT D R DERC T SMOKE DETECTOR FLEXIBLE CONNECTION TRANSFER GRILLE MAKE UP AIR UP- THROUGH ROOF DIAMETER MINIMUM 1" UNDER CUT 16X16" DOOR LOUVER SUPPLY FAN SCHEDULE SMARKL MAKE & MODEL NO CFM S. P. RPM HP VOLTAGE /PH AREA SERVED ROOF OPENING WEIGHT NOTES 0 CAPTIVE AIRE NSAU1 -G10 1,105 105 0.5" 697 0.333 115V, 1 PH HOOD # 1 23 "x23" 184 LBS. 2,625 0 (5) RANGES, (1) OVEN 0 CAPTIVE AIRE NSAU2 -G12 2,625 0.5" 663 0.750 208V, 3 PH HOOD # 2 32.5"x32.5" 275 LBS. 16 "x16" 0 _ Q O CAPTIVE AIRE NSAU2 -G12 2,700 0.5" 669 0.750 ` 208V, 3 PH � HOOD 3 # 32.5 "x32.5" 275 LBS. _ © 9 -0 0 CAPTIVE AIRE NSAU1 -G10 1,105 0.5" 697 0.333 115V, 1 PH HOOD # 4 23 "x23" 184 LBS. 450 0 0.109 HOOD SCHEDULE SYMBOL MARK LENGTH EXHAUST CFM MAKE UP CFM S.P. APPLIANCE UNDER HOOD EXHAUST DUCT MAKE & MODEL AM 6'-6" 1,300 1,105 0.370 (3) RANGES III 12 x10 CAPTIVE AIRE 4824 -ND -2 -PSP -F Q 332 ® 15' -6 3,500 2,625 0.454 (5) RANGES, (1) OVEN 16"x16" CAPTIVE AIRE _ 5424-ND-2-PSP-F 0 - © 12' -8" 3,600 2,700 0.525 (3) FRYER (2) GRIDDLE, (1) RICE COOKER O O O 16 "x16" CAPTIVE AIRE 4824 -ND -2 -PSP -F Q 80 © 6 -6 " 1,300 1,105 0.370 (3) FRYER 10"x12" CAPTIVE- AIRE 4824 -ND -2 -PSP -F 0 _ ® 9 -0 1,350 0 0.109 (1) OVEN �) „ " 14 x8 CAPTIVE AIRE 4224-VHB-G lEr 0.4 ® ._ 30 " 450 0 0.109 (1) STEAMER ► ,, 12"x12'' TYPE II CANOPY HOOD " " " 36.36 x24 W YORK AHP48D NOTE& EACH HOOD AND RELATED EXNAUST FANS AND MAKE -UP AIR WITS ARE ELECTRICALLY. INTERLOCKED. EACH HOOD IS EGJIPED WITH AN APPROVED ANSUL FIRE PROTECTION SYSTEM THAT WILL TURN OFF THE GAS VALVE TO ALL TI.E COOKING EaJIFMENT UNDER 114E HOOD AND ENERGIZE tI•EE ANSUL SYSTEM AT SAME TIME. UNIT HEATER " SCHEDULE MARK (ACF #) MANUFACTURER MODEL # HEATING ELECTRICAL TYPE INPUT (MBH) OUTPUT (MBH) EFF VOLTS /PH HP REMARKS f db REZNOR UDAP -400 ` NG 400 332 83% 120/1 1/2 FIELD ADJUSTED FOR OPERATIONS AT SITE ELEVATION. 120/24 VOLT CONTROLS. ® liar 1,500 AIR CONDITIONING' AND FAN COIL SCHEDULE I.D. ` TAG MANUFACTURER & MODEL NO. NOMINAL TONNAGE ' COIL Twb AIR OW (C O.A. (CFM) KI:S.P (IN. W.C.) VOLTS PHAS� UNIT TOTAL HEALING WEIGHT REMARKS f db 'F MCA FUSE CAPACITY (KW) MODEL MI EXISTING TRANE SFHC -C304 30 80 67 15,000 1,500 2.0 460V./3 - _ _ _ 0 EXISTING UNIT FLA = 75 v 4 EXISTING TRANE SFHC -C304 30 80 67 15,000 1,500 - 2.0 460V./3 - - _ _ _ EXISTING UNIT FLA = 75 e:::AC z An YORK AHP36C 3 80 67 1,200 120 0.4 230V./1 29.5 30 4.8 4HK6500506 159 LBS. YORK / YZS02411 2 ® YORK AHP48D 4 80 67 1 600 160. 0.4 230V. 1 / 29.8 30 4.8 4HK6500506 179 LBS. 2 24000 20000 YORK AHP48D 4 80 67 1,600 160 0.4 230V./1 29.8 30 4.8 4HK6501006 179 LBS. YORK AHP18B 1.5 80 67 600 50 0.4 230V./1 1 15.4 20 2.5 4HK6500206 - 125 LBS. ® YORK AHP18B 1.5 80 67 600 50 0.4 230V./1 15.4 20 2.5 4HK6500206 125 L: IEWED FOR 0 APPROVED SPLIT SYSTEM HEAT -PUMP SCHEDULE MAR 2 2 2010 UNIT Numeem MAKE /MODEL • NOMINAL CAPACITY (TOW COOLING CAPACITY 811114 44EATI CAPACITY 131144 I ELECTRICAL DATA TOTAL WT City of Tukwila BUILDING I VOLT. PFD 14Z MCA MOGP SEER FLA ink YORK / THGD36 3 36,000 28000 208 3 60 Ds 20 S 10.6 220 LOCATED ON ROOF ON STRUCTURAL 1•EM ER 0 AILI YORK / THGD48 4 48,000 34000 208 3 60 133 S S 125 250 LOCATED CN ROOF ON STRUCNRAL t•EMBER v YORK / THGD48 4 48000 34000 208 3 60 12 S S 125 250 LOCATED ON ROOF ON STRUCTURAL MEMBER An YORK / YZS02411 2 24000 20000 208 1 60 188 30 14 152 250 LOCATED oN ROOF ON STRUCTURAL MEMBER Q YORK / YZB02411 2 24000 20000 208- 1 60 I88 30 14 152 250 LOCATED ON ROOF ON STRUCTURAL MEMBER 0 RECEIVED MAR 10'2010 PERMIT CENTER E ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHT: NADEL RETAIL ARCHITECTS, LLP. ALL RIGHTS RESERVED. B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00-00 NHOEL RETHIL Nadel Retail Architects, LLP 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.8262100 F. 310.826.0182 www.nadeiarc.com Bffirel (.9 z� o w w z ca �z UW z - 2 aw I-- w co N. a 6) cn cu co O s a Inam U w 0 0. tin Lu Q _ Z tin In V Z Q W Q DRAWING TITL REVISIONS: Q 03 -01 -2010 Q O 0 A A O 0 A 0 A A_ DATE 12- 17.09 JOB NO. 09293 SHEET NUMBER M -1 i __ ®Iiiil • IIJ.� ►� Ir .� /- /x.01► , - ....--1,..-K.7•0 l y • ■T / �►A -ate = ..NUoi = �® I1=1110111s i1 I ■11a • .R Nadel Retail Architects, LLP 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F. 310.826.0182 www.nadelarc.com 474 . w w Q Q�0474.7670 ►. A: Q674 l O ! O i . 1 X604,1.1WW,11 4M..., +fir 11, :.• :• :. :• : •• :• :. : ∎ :•:■∎:•:o.:.•rii II vi 4 EG -1 100 CFM (TYP. 4) ige -� `� = =-- -� �. ►. .� :,' ��� ® ® /// /mss 1 ®® AM PI 11 1 1 is a •!I (� ' 0' '-sue PRIMMEM Mo CME iiiinMf 1 E 1 ®.......... ®rni --. 1 ® ®Ni ®1. \1 `I :::::ms 111111.1.111 Miiiiiimminil ' hm mlli 1 1ii lye ® ®O® ® ® ®I ®1 Assowom IIi— _1®I ■I ® ®IME ®�: w�� \ it • 11110 Ma> .;.o• - ®I . mil. %6&:ianfiki,, „mill Anil _SIC,/�� t!��u,Lti/_.'.i► ,�.� lmom ®1I ® ■E, I�;iL�i _..►arias , �� !28"x46f1°+ -1 III AlEIM — PI III .. �''L,MI®® ®III I ®1 I e -6 �1 ,� �. II! �.. ►��.�/lU A IIIIlI _ �, CFM A � , � IIi UIIII®1 1 _ 0\/. r- I1II ® I• -� � � ar _ �► _ ����� �� .. O �1�1 RI TIM n®m oI i1 1 :.a.. I. v i -- =_ .7„,;.-_-:m■sommismons.. .„ 11% I - .i -. -,■_ �. -_ -.- MINIM ..... -. -∎_ - • - \11,� III mom -� -�- • � .; ��lO�l 11 �' /L� l:��� — DE: I f � r i 7�i11' : •Y ,� Vie.. ,al n, r -.i� �►1�i� /11. �.�� margeAriow- 1/1111111■11111111111M110511/11■11111WM. Ill Mo 111.111111111111111111511, 1 --- 44;;;---- _._ �- 6111I Ir' -' = y, i- ti' i �' 4114111116111111111R 3 / /,�I�� ;emu . '���� ®1I;► /1i� pm._ 111111111111•■•1111111/1011 re -t/ tl �! III V ®►/�I�ii����!llotamm—. iii ri 29,Ig1 Mratici— �_ linwer ./•:■■■■••■■••••1 MEM IMIMI1■11•■■■•■II,MIAI LIIIPM6111P111.11.11 lip-% y 1■eWAI!?�!-!�IeerjIMllaVe veimIi� ;! .. .....-nom BIM ■p �- CODE REVIEWED FOR C C P COMPLIANCE A ROVED MAR 2 2 2010 REVISIONS: A A A A A A A A A A A ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT, COPYRIGHT: NADEL RETAIL ARCHITECTS, LLP. ALL RIGHTS RESERVED. 1/8•.11 -0• B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00-00 Nadel Retail Architects, LLP 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F. 310.826.0182 www.nadelarc.com 'EA -1VAC 'EMVAC (E)2TU -3 10 "x10" DUCT UP TO ROOF TO GOOSE NECK COVER OPENING WITH 1/2" GALVANIZED STEEL WIRE MESH. 'E)NVAC "E)NVAC (E)RTU -1 'ENVAC 12"x12" DUCT UP TO ROOF TO GOOSE NECK COVER OPENING WITH 1/2" GALVANIZED STEEL WIRE MESH. EMVA 6 "0 DUCT TO ROOF FROM EF -9 REVISIONS: D03 -01 -2010 Q 0 0 0 0 0 L o DATE JOB NO. I/8' =P -0' ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBUSHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHT: NADEL RETAIL ARCHITECTS, U.P. ALL RIGHTS RESERVED. B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00 -00 Nadel Retail Architects, LLP 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F 310.826.0182 www.nadelarc.com 2006 IMC /SMACNA WA STATE AMENDMENTS ACCESS PANELS IN GREASE EXHAUST DUCTS ARE TO 8E A MINIMUM OF lb" 1-IC I-I EY 24" WIDE AND LOCATED AT A MINIMUM DISTANCE OF NO LESS THAN 1� /a" FROM THE BOTTOM OF THE DUCT: IF THE SIZE OF THE DUCT IS NOT LARGE ENOUGH TO ACCOMMODATE A PANEL 16x24 THE HEIGHT OF THE PANEL MAY VARY 5Y THE I -EIGHT OF THE DUCT MINUS 2" SUT THE WIDTH OF THE PANEL SHOULD NOT 8E COMPROMISED. FURTHER THE ACCESS DOORS IN THE SHAFT SI -IOULD BE 12" LARGER THAN THE DUCT ACCESS PANELS IN THE DIR- ECTION TI-IE DUCT WILL BE CLEANED, TO ALLOW FOR ANGULAR ACCESS INTO THE DUCT. THE SELF CLOSING SHAFT DOORS MUST 5E LOCATED SYMMETRICALLY AEOUT THE DUCT ACCESS PANEL, AND THEY MUST 1-IAVE ROOM BETWEEN T�-IE SHAFT AND ANY INTERFERANCES SUCH AS PIPES, CONDUITS, HANGERS, OT1 -1ER DUCTS OR BUILDING STRUCTURE, TO ENABLE: THE DOORS TO SWING INTO A FULLY OPEN POSITION AN APPROVED_ FIRE EXTINGUISHING SYSTEM SHALL EE PROVIDED FOR THE PROTECTION OF ALL COMMERCIAL GREASE HOODS AND DUCTS. ALL FIRE EXTINGUISHING SYSTEMS SHALL i3E IN- TERCONNECTED TO THE FUEL OR CUR - RENT SUPPLY SO THAT THE FUEL OR CURRENT IS AUTOMATICALLY SHUT OFF TO ALL THE EQUIPMENT WHEN THE FIRE EXTINGUISHING SYSTEM • I • IN COMPLIANCE WITH 200 WASHINGTON MECHANICAL CODE. lIJASHINGTON THE COMPENSATING AIR QUANTITY IS 5ASED ON 80% OF THE EXHAUST CPI THE REMAINING 20% IS INTRODUCED TO THE AREA THRU THE A/C SYSTEM. WHEN TYPE 11 -IOOD FIRE EXTINGUISHER SYSTEM DISCHAR ES, MAKE UP AIR > SUPPLIED INTERNALLY TO A HOOD SHALL BE SHUT OFF. THE CITY OF TUKWILA WILL CONDUCT AN INSPECTION AND TEST TO INSURE SHUT DOWN OF MAKE UP AIR. / , AM / 41*Y4r/f, • %a 0 - /4461 p -401 ■••1 a Awv",■16AVIll .1441P• A .411, Aret- A/ 4 in )) #4 ACIIIMM:111 MEM I alawsmjskttv 107,,, • O p\ 1L1 1�111111111ri'll!liiIa1 �i- r IIII I ii WEN �� ®�/Iii ,AI/N 1 \ I r.�� r -�aIC 9,50 IN r DRAT BD MAKE UP AIR SHALL BE IN COMPLIANCE > WITH SECTION 508.1 4 5081.1 OF THE 2006 INC. > SECTION 5063.12. MAKE UP AIR DUCTS CONNECTING TO OR WITHIN 18 INCHES OF > A TYPE I HOOD SHALL BE CONSTRUCTED 4 INSTALLED IN ACCORDANCE WITH SECTIONS 603.1, 6033, 603.4, 603 9, 603.10 4 603.12. DUCT INSULATION INSTALLED WITHING 18 INCHES OF TYPE > HOOD SHALL BE NON- COMBUSTIBLE OR SHALL 8E LISTED FOR THE APPLICATION. SECTION 5012.1.1 OF THE 2006 IMC. TYPE I HOOD SYSTEMS SHALL 8E > DESIGNED 4 INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE `ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES BY MEANS OF HEAT SENSORS OR 5Y OTHER APPROVED METHODS. SECTION 50633.1 OF THE 2006 INC. A GREASE DUCT TEST SHALL 5E PERFORMED FOR THE ENTIRE DUCT SYSTEM INCLUDING THE HOOD TO DUCT CONNECTION. THE DUCT WORK SHALL BE PERMITTED TO BE TESTED IN SECTIONS, PROVIDED THAT EVERY JOINT IS TESTED. SPECIAL' INSPECTIONS' ARE REQUIRED FOR ALL GREASE DUCTS > 4 HOODS THROUGH A QUALIFIED/ WAEO CERTIFIED AGENCY PRIOR > TO INSTALLATION AND /OR DUCT INSULATION. SCALE 1/4'•1' -0' 16 t;.: II :mss ►L I •rT •T T ♦ ♦ ♦ ♦ T •1 T. -�T •r •rT •r \''. ∎ _..:.------------ - - - - -- - - - -� -- --------------- - - - - -- r `+I � 1. I •I. ' '4 - -- — --------------------- - - - - -- — - -- — _ o_ o_ o_ s_ o_ o_ o_ o_ o_ o_ o_ o_ o_ o_ o_ o_ o_ o_o_o_o_s_o_o_o.�_o_s_o_o_o_o,� �►_o_f _ _ ___..____ _ _ _ o_ o_ o_ o_ o_ �o _o_o_o_o_o_o_o_o_o_o_o_o_o_o__ _-- _ _ .___._._._. _ _ __.__ - 191.17evojami Nr P►�I /IJb J WiffallIF: 1 DIFFUSERS, REGISTERS AND GRILLES SCHEDULE MFR 81X1= MO(NTMG MATERIAL CFM 8YMBOL. CATl SIDE L C1.Cx. DUCT STEEL AL FINISH DAMPER SD -1 KRUEGER 12 "x12" 6 "0 B A 100 -120 1400 SD -2 KRUEGER 8 "x8" 6 "x6" • 50 -195 880H SD -3 KRUEGER 24 "x24" 10 "0 B A 220 -400 1,400 SD -4 KRUEGER 24 "x24" 12 "0 400 -500 SD -5 KRUEGER 24 "x24" 15 0 rim .....-01 B A 700 -850 1400 SD -6 KRUEGER 28 "x12" 26 "x10" • ° B A 800 -910 880H LSD -1 F�i� 10 24" 24" B A 200 RG -1 KRUEGER 18 "x18" 16 "x16" B 500 -800 RG -2 KRUEGER 24 "x24" 22 "x22" B 1080 -2000 580H RG -3 KRUEGER 24 "x48" 22 "x46" B 2500 -375C 580H RG -4 KRUEGER 28 "x28" 26 "x26 " - B 2500 -375C EG -1 KRUEGER 12 "x8" 10 "x6" 50 -100 580H _ EG -2 KRUEGER 18 "x18" 16 "x16 "' ° B 500 -800 580H TG -1 KRUEGER 36"x12" B 580H pammo �.� - lir ,F ■NOW111111111p1 /-X ' �ig ° - - -• / / 1) I ' SUITE 150 i. fI Altitk4114! 7 1 ilri Wpr WI 1\0\ 3), /12),(6 I / 1 4 - 4 0 1R AI �c Aoi \I A Rim m. 1 ..�►.. >. .. "7::: �� Aim, Fp li Ail C111111111111111MII 212111111111111,14 / A e ,_.,, is E� 0r44 ii !UW KITC-IE 4 50 -1 3 REVISIONS: DATE JOB NO. ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT, COPYRIGHT: NADEL RETAIL ARCHITECTS, LLP. ALL RIGHTS RESERVED. B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00 -00 ' B.D. SUBMITTAL: 00 -00 -00 • MFR 81X1= MO(NTMG MATERIAL CFM 8YMBOL. CATl SIDE L C1.Cx. DUCT STEEL AL FINISH DAMPER SD -1 KRUEGER 12 "x12" 6 "0 B A 100 -120 1400 SD -2 KRUEGER 8 "x8" 6 "x6" • 50 -195 880H SD -3 KRUEGER 24 "x24" 10 "0 B A 220 -400 1,400 SD -4 KRUEGER 24 "x24" 12 "0 400 -500 SD -5 KRUEGER 24 "x24" 15 0 rim .....-01 B A 700 -850 1400 SD -6 KRUEGER 28 "x12" 26 "x10" • ° B A 800 -910 880H LSD -1 F�i� 10 24" 24" B A 200 RG -1 KRUEGER 18 "x18" 16 "x16" B 500 -800 RG -2 KRUEGER 24 "x24" 22 "x22" B 1080 -2000 580H RG -3 KRUEGER 24 "x48" 22 "x46" B 2500 -375C 580H RG -4 KRUEGER 28 "x28" 26 "x26 " - B 2500 -375C EG -1 KRUEGER 12 "x8" 10 "x6" 50 -100 580H _ EG -2 KRUEGER 18 "x18" 16 "x16 "' ° B 500 -800 580H TG -1 KRUEGER 36"x12" B 580H pammo �.� - lir ,F ■NOW111111111p1 /-X ' �ig ° - - -• / / 1) I ' SUITE 150 i. fI Altitk4114! 7 1 ilri Wpr WI 1\0\ 3), /12),(6 I / 1 4 - 4 0 1R AI �c Aoi \I A Rim m. 1 ..�►.. >. .. "7::: �� Aim, Fp li Ail C111111111111111MII 212111111111111,14 / A e ,_.,, is E� 0r44 ii !UW KITC-IE 4 50 -1 3 REVISIONS: DATE JOB NO. ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT, COPYRIGHT: NADEL RETAIL ARCHITECTS, LLP. ALL RIGHTS RESERVED. B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00 -00 ' B.D. SUBMITTAL: 00 -00 -00 HOOD INFORMATION HOOD TAG LBNCsT14 MAX =KM TOTAL 113•P. EX1F GM UADNH LENS. D1A GM EX44AU5T PL2L1 RIS) 'TOTAL SIP. C SUPPLY PI.E .M RR18ERlS) D4l SR HOOD CONSTRICTION HOOD GCMG. END TO DID 14-1 4824 ND -2 -PIP-P 4'600' D' -0310" 43086 Share Expose 14-2 3424 ND -2 -PSP -F 15' 400' 16' W' tq0 -0454' 0464' 262"5 43086 Uwe Exposed 14-3 4824 ND -2 -PSP -F D' 8]00' 10 IWO IV -03211' 430 86 alws Expcxed 4824 AD- 2-P8P -F b' 6001 D' -0310' 43086 Ewe Exposed 9' 000' 14' 14' DSO -0]09' 430 86 1003 14•nnn. TATTi'n)7alATTfW HOOD OPTIONS LIEaT QUARTER ETD PANEL 23' Top Width O' Eaton Width 23' WO 43086 LEFT END STANDOFF 3' Wide MIGHT END STANDOR• (FWBFED) 3' Wide 14 D NO. FLIERS) LIGHT(8) LITtLM CAEl1ET(8) SYSTEM PPM 11000 HHOODG a�,11r GI TYPE EM HEIGFif Li9NG1H 1m TYPE ' GBAI� lu LOCATION D' EL eurtiehC -b TYPE 6121= MoDI�. • a�aNTmr LOCATION 1 86 Baffle with Handles i k's B', 2 Era idac IJ t Rd ND Right Mw11R102 30 n111cF1� (Light Fan i Hal Outsids Yi21 366 Lab BULDING CODES ib' 20' a 66 Baffle NGRFI Handles 3 GENERAL. NOTES W ` 3 ledaNNdasont L4ght FDd NIO Rk�T1 haul 8102 3]0/30 31110FP T 1 I Fan Outt+ido YEt) 610 Lab 7 di 16' 2C 3 - 86 tam. oh Handles 2 W' W' 4 M1caHCMos* 14 * FDt! NO L.m t Atsul 8102 30/30 311110FP i L1sht i Fan ONNbtd. YES 606 LJ36 10 16' 2C 4 86 eaffl. idyl Handles atesailAls 11 N 1 ileaNdoo�I! L4 jt P14 Np 24' 900 0J46' 4 Front 1'Eb 331 Leh 61 :• 24' 3 1104 0J60' 1 4 ;4 7_ 111p g Incandescent Lied Rd i 4 f�T'"?�I 1411•11 PFC-1:L11 JAN WIRING TO CONTROL r PANE. s HUM iND 233 1438 IIsCTRIC GAS VALVE WITH RESET REu MANUAL RESTY =AY cams REIM ' . ■ HOOD OPTIONS LIEaT QUARTER ETD PANEL 23' Top Width O' Eaton Width 23' WO 43086 LEFT END STANDOFF 3' Wide MIGHT END STANDOR• (FWBFED) 3' Wide 14 D NO. F178 LENGTH U1D1N FEIGI4t 1/2" CONNECTED THROUGH ANGLE *ROD Help* *ALSO GI aJ>DTH LENd` DUI CA'I SP• 1 Prat 90 D' 6' 10 24' 2.00" 904 0)10 2 per, 196' 12' 6' lo' 16' - 48"X48' 636 0121' 2.25" 1179.50' HANGING ANGLE LOCATIONS CANTLE- -IRE H000S ARE BUILT IN COMPLIANCE WTI • 10' 16' BULDING CODES 686 OM' E 3' UTMOULATED SNWT COLMUS E E 3• MULCTED STANDOFF CLEARANCE TO COMI3UST13LES tEldLlna 1 ALL EJOIRCAL MCI Iff 1112111CAL COO OR AO MAO* MneoaleCllas LPUII /IV MAID fMn020111�iC. gff } 0RMCp 0. HsnIML7NCIN1eLOGCIEDNb au= assume PL4d N1 OOREMIltFI IN AUIFIN INONYNTAILNf0201 W0112 4 01100NNCIRNeRNNCA ■IDi14111111210112RIEGIUNFAL 0 MGssurn eSENFNRMMWQFi12 A IMU RMMTOMNG HNMW0TO 1. ALL 110110110111 SON NGLLLIDWrC1l1hL41AATtAIeFACTORY FI!•MD. 111211121•110110110111111111107011•07021010112 EY A Lane= 1411 WrN011/100A1MCIgN 0. MOW mornmeMeYNllEMOlneunOF neALLHIC 101107a10. M F.ULLNSGIEEPAC1OMMIIFS AIL ELRODu SlanunroR 6l1G11C11GF D MING1 L12NAGLMANDpl8110021111011 FOR 40211101:N1111RA C1LADAGIOitM11GNGP OETE nE4HCT PPP! TOitlfHUMEMRF OTECiKNGP GRACE 1 mall' IICCOI NIRYInALACIDtN101E1ri 0. MOM NULL . MIAMI MTN INAMTTOM B * ANT IL PrTAMR HULL 1111 FbtIUMtRH.1F10TOAIEEMUM M N n11ramCODDFCiYONS HAW Fl®C®CCMOMetIGYt a IDINID AD wigwam. OWENCI1 DID DOCIMDC PUB 11. IMCM0111MRA012E 14110 1011X1 lRCI.IRQTG.NIMA111i GENERAL. NOTES RESISTANCE VS. AIRFLOW - 2^ Klan -cam Baffle Type Gee Fa IC 16' tNCA14FA be6 0121' 1900 NM y 10166 0900 1 ler 16' 0.111 ..-44 683 0J21' 3 F 164' 16' 6' 10' 24' 16 900 0146' - ,... 1C0/11,1 A 1 10 /IX SWF= 3/1R ... /,- AIRFLOW (fpm /m/s) (el INIZENII MOWS sentrusa Kleen -Gard Baffle Type Filters are UL Classified Grease Extracting Filters. MEA # 168 -78-M Aluminum MEA # 247 -96-E Stainless Steel FLTER DETAL malD -eMa+• WOW MEIN GoIOUCIm TO I Nf>1CJaiM9T. =UM PA Is ERE SOME SEMI : . , 10 24' it A, see VMS II 1110110S1 900 8346' atesailAls 11 N N tX 10 24' 900 0J46' 4 Front 84' D' 61 10' 24' rte, 1104 0J60' Are System Info m tton 1146TALLATION SY81S1 LOCATION ON HOOD AntW R222 PRa Cabinet Right And 1 Fire Cabinet Aral 12102 Fite Cabbie! Lett Ancil 14102 Wall Mout Right WA 111 00011cal'D, PLAN VIEW Hood #5 (H -5) 9' 0.00" LONG 4224VHB -G i e i i i i i i i i i i i i i i i i i i i i i i if i ii i iii i i ii 111111.11° / O ULUsbd bossossours Light Reare4Igh rep CONTRACTOR TO PROVIDE - 4' WIDE 81.EET METAL COLLAR AS EHOLLt,, ON FROM' MD BOER OF THE OVE1 60 k''S`d91 1MI I PLAN VIEW Hood #1 (H -1) 6' 6.00" LONG 4824ND -2- PSP -F EXHAUST DRAIN PERIMETER GUTTER iF IRE - IoM SYS'i FACTORY PREMED CONDUIT ELECTRICAL PACKAGE WITI4 FAN FAN TNA AND PJPPL CAL FoIR DETAILS) LKsI4T.e (LIGHTS . F PiREWIRED BY CAPTIVE -MIRE SYSTEM 1NCANOEECE NT LIGHT FiXfUFE -HIGH 1E1"P Y, HELLOES CLEAR 111zl1P141. AND SHOCK RESISTANT GLOM (1.83 FIXTURE) TOP OP CNEN REED OVEN BY OTHERS SECTION VIEW - MODEL 3624VHB -G IT 18 714E RESPONSIBILITY OF THE AIRC14FTEC1/G1.1NER TO ENSURE 1144T THE 14000 CLEARANCE FROM LIMITED- CCM0u8T115La AND COMBUSTIBLE MATERIALS IS N COMPLIANCE WiT 4 LOCAL CODE REQUIREMENTS 1/2. DNA ML THiOE ROO CasECNED 10 ROOF MT THROUGH N1On HAMMITT NNmE *ROD ND PUTS 10 BE SUPPLMD HANG** ANGLE is PRE -PUNO e iINSO USED METH TYPE D 2 HOOD 1/2. DNA = Ole HEAVE HAMM BY NSTML=J0 CONTRACTOR AT FACTORY YODELS as 4 HOW DUTY AIN MO ONE ES10W MIELE VHD-S PD-2 HANGI4G ANGLE DETAL 1/2" CONNECTED THROUGH ANGLE *ROD Help* *ALSO DN► AiL iHREAD 70 ROOF ANOTHER MD JJTS i0 ANGLE a USW MOH ROD 1/a JEST ONE HANG'S HADICNO -, : ® EE Swum IN 1100111140 PRE-FUNCHED AT FACTORY WE 2 HOED MORELS OH. ink now OUW tour ABOVE AND OM LEUX ANixE MEtL H AMM ANGLE CONTRACTOR %HI -s. .i• A VHC ND HANGING ANGLE DETAL HOOD STYLE DDIIM M DIM FROM WA DIM FROM { CANOPY ND2/ND2 -PSP -F 4.17' 2.25" 225" ND/ND -PSP -F 2.00" 10.50" 8.00" BACKSHELF 284760 2.00" 1425" N/A giros& VHB/VHB -G VH 1 /VH 1 -G 36"X36" 42"X42" - 48"X48' 2.25' 579.50 225" 11 "/9.50' 2.25" 1179.50' HANGING ANGLE LOCATIONS CANTLE- -IRE H000S ARE BUILT IN COMPLIANCE WTI • NICAI6FA NSF. = NEPA' BULDING CODES JIS'E81eL 1000 E 3' UTMOULATED SNWT COLMUS E E 3• MULCTED STANDOFF CLEARANCE TO COMI3UST13LES tEldLlna 1 ALL EJOIRCAL MCI Iff 1112111CAL COO OR AO MAO* MneoaleCllas LPUII /IV MAID fMn020111�iC. gff } 0RMCp 0. HsnIML7NCIN1eLOGCIEDNb au= assume PL4d N1 OOREMIltFI IN AUIFIN INONYNTAILNf0201 W0112 4 01100NNCIRNeRNNCA ■IDi14111111210112RIEGIUNFAL 0 MGssurn eSENFNRMMWQFi12 A IMU RMMTOMNG HNMW0TO 1. ALL 110110110111 SON NGLLLIDWrC1l1hL41AATtAIeFACTORY FI!•MD. 111211121•110110110111111111107011•07021010112 EY A Lane= 1411 WrN011/100A1MCIgN 0. MOW mornmeMeYNllEMOlneunOF neALLHIC 101107a10. M F.ULLNSGIEEPAC1OMMIIFS AIL ELRODu SlanunroR 6l1G11C11GF D MING1 L12NAGLMANDpl8110021111011 FOR 40211101:N1111RA C1LADAGIOitM11GNGP OETE nE4HCT PPP! TOitlfHUMEMRF OTECiKNGP GRACE 1 mall' IICCOI NIRYInALACIDtN101E1ri 0. MOM NULL . MIAMI MTN INAMTTOM B * ANT IL PrTAMR HULL 1111 FbtIUMtRH.1F10TOAIEEMUM M N n11ramCODDFCiYONS HAW Fl®C®CCMOMetIGYt a IDINID AD wigwam. OWENCI1 DID DOCIMDC PUB 11. IMCM0111MRA012E 14110 1011X1 lRCI.IRQTG.NIMA111i GENERAL. NOTES RESISTANCE VS. AIRFLOW - 2^ Klan -cam Baffle Type Gee Fa REsIsrANcn (in. w.&) 4 tNCA14FA NCA44FA ERA 1900 NM y 10166 0900 1 7 80 0.111 ..-44 3 NGA10T'A NCAUOFA' Ep-5 1330 Ld l 0333 1 16 111 95:12 - ,... 1C0/11,1 A 1 10 /IX SWF= 3/1R ... /,- AIRFLOW (fpm /m/s) (el INIZENII MOWS sentrusa Kleen -Gard Baffle Type Filters are UL Classified Grease Extracting Filters. MEA # 168 -78-M Aluminum MEA # 247 -96-E Stainless Steel FLTER DETAL r7 I O 1 m f" AIZZ UL Used MlcrOdssant 141 its hre4ligi 250000 462000 kitIM WINOS L • APNSUL. -102 ION CHEM FIRE SYSTEM FACTORY FACTORY PREUARED CONDUIT PREWIRED ELECTRICAL PACKAGE WITI4 SUPPFLY FAN SSHU"r DOU.N RELAY. (SEE ELECTRICAL DRAWINGS FOR DETAILS) LIGHT 4 (LIGHTED) FAN SWITCH PREWIRED BY CAPTIVE -AIRE SYSTEMS. 490000 A 48UL R -102 WET ICAL FIRE SUPPRESSION YSTEM FACTORY PREWIRED CONDUIT 30000 490000 6' 6. 0TNon/E' 600'00 PLAN VIEW - Hood #2 (H -2) 15' 6.00" LONG 5424ND -2 -PSP -F NOTE: Additional hanging angles provided for hoods longs than D R 490000 463000 26 -4411111% 480000 PREWIRED ELECTRICAL PACICAGE WITH FAN STARTERS AND (SEE ELECTRICAL DR WINGS F DE All LLS) LIGHT 4 (LIGHTED) FM SWATCH PREWIRED BY CAPTIVE -AI1RE SYSTEMS IMOD t m / 114: 160000 I-ITJ0000; 21... listed Worduart ra -Nigh T • 160000 D' 8001Noe112' SAVOR 540000 1-24/Delf:. I 380/000 PLAN VIEW Hood #3 (H -3) 12' 8,00" LONG 4824ND -2 -PSP -F NOVA Additional longing cosies provided for hooch War then D ft. EXHAUST 1NANGTNG kb' 8S EARLE UATN HANDLES AND ' INTERNAL ST IT 18113 RESPONSIBILITY C. 'F THE ARCHITECT /OJ TO EN6tRE /NAT THE HOOD CLEARANCE RRd1 L9'UTED- CONDU6 AND COMBUSTIBLE MATERIALS le N COMPLIANCE MI LOCAL COPE RECEIFE EHTet GREASE ORAN WEN REMOVABLE GP i� Arkv. "4 .17-1W17 ."1%" .ffe'4% 7,1°.?":"' rfr r• 11, 1 Nur UL Listed O I�mee•1A 1 T•» p J to 6' 600Noe/6' 600'00 PLAN VIEW - Hood #4 ' (H -4) 6' 6.00" LONG 4824ND -2- PSP -F • INCANDESCENT LIGHw MITRE-141644 TRIP Y, MUM CLEAR 1HER'IAL AND SNOOK RESISTANT GLOBE (1.53 MAW EOWFMETNT BY OTHERS ATTACHING PLATES awarLY RI6ER WITH VCLL1•E DAMPER 2.'13 2333 OPEN 6TANLE88 - STEEL. PERFORATED PANEL SECTION VIEW - MODEL 4824ND -2 -PSP -F HOOD NUMBER 1 & 5 SCALE NTS HOOD NUMBER 2 THRU SCALE NTS EXHAUST PAW TWWfPltlATTfW FAN 1ST N0: RN UNR 1160EL • P10DEL TAG CFht SP. iRPM HIP. t VOLT fLA WEIGHT' (Lab) 1 NCA1�A NCAM4FA E3-1 1900 0200 1066 0900 1 IB Om 12608 2 NCAW94 NCAJ6FA EF-2 3300 1000 110 1500 3 206 41 16048 3 NICAI6FA NCAI6FA )5~3 3600 1000 19) 1311 3 206 4.1 16045 4 tNCA14FA NCA44FA ERA 1900 0900 10166 0900 1 lib 80 OM 3 NGA10T'A NCAUOFA' Ep-5 1330 OSOO iA2 0333 1 16 111 95:12 FAN .NIT Na: MN UNIT MODEL • BLOWER 110t161NG TAG CFM 8!? RPM HP. - t VOLT FLA WIGHT (LEE) b MAUI-610 GTO NCAW ST-1 1106 03e10 491 0333 1 >D 70 164WP 7 NM L .GD GD iN8AUL2 eF-2 2623 0300 663 0130 3 208 L7 231.T1 8 N8.4112412 GD N6AW2 8R3 7100 0300 66 020 3 ?J08 2.1 2P LIT 9 ROAM-00 Gib iNSAW W-4 105 ' 0300 d' 1 0333 i l i0 184)0 FAN OPTIONS 1- Grease Boot 1- exam Sax 1- Grease Box 1- Grease Box' CURB ASSEMBLIES NO. 04 FAN CAFA BERES UPBLA T E)OiAUST FANG 4A-762) W ffA73 ROOF MOUNTED FANS ▪ RESTAURANT MODEL - UL162 - RICA BOUND AND AIR CERTIFIED - WIRING FIFO 1 MOTOR TO DISCONNECT SWITCI4 - WEATHieRl•ROCP DISCONNECT - HIGH HEAT OPERATION 3007E (14910) - GREASE CLAe81FICATICN TEeTNG NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTTh41OUSL' WHILE EXHAUSTING AiR AT 3007E (1497C) UNTIL ALL FAN PARTS HAiiEE REACHED THERMAL EGWLIBRIU" , AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTMJOUSL WHILE EXI4AUSTNG BURNING GREASE V AT 6007E (316tC) FOR A PERIOD OF 134 MINUTES WTHOLtr THE FAN BECCM DAMAGED ED TO ANY WENT THAT AN UNSAFE CONDITION. GREASE BOX H NGED FM PITCHED CURB INSULATED CURB NCAPA BELT PRIVE CEN1RIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA PAW MODEL A D NCAIOFA 191/2 20 NCAI4FA J FILTER SIZE NCA10PA 211/4 301/4 2 21 211/1 13 2 NG414FA 30 12 33 3/4 2 24 3/4 23 141 "°r. - 2928 NCAI6PA 33 3/4 39 3/8 2 28 23 1/2 16 I/2 ` 24 190 STANDARD SERIES DOWN DISCHARGE ` SUPPLY FAN EXTERNAL SERVICE OISCOhNECT SUPPLY PAN E .EGTiRTCAL DROP NGMMLTit ROMA IMATV M 20 GAUGE STEEL CONSTRUCTION ROCP 1P�Cs ENIN PITCHED CURBS ARE AVAILABLE FOR PITCHED ROCFS SPECIFY PITCH: EXAMPLE. 7/12 PITCH ■ 3018L.CPE CURB DIMENSIONAL. DATA FAN MODEL A D NCAIOFA 191/2 20 NCAI4FA 23 FILTER SIZE NCA16FA 26 1/2 20 SUPPLY AIR UNIT DIMENSIONAL .DATA BLOILER A D C D EE F FILTER FILTER SIZE UEiGHT 10' 26 32 28 23315 2L1S 26.815 2 16' X 20' f lb LBS 12' 3i 40 35 313 26.815 2928 2 20' X 23' 2113 LBO GALVANIZED SUPPLY FAN FILTER AIR INTAKE THROUGH FILTER G-2 CURB WTH 20 GA. CONSTRUCTION 3' CONTINUOUS Fi.ASHNG BLOWER OUTLET SIZE ROOF OPETNMG CURB /ROOFTOP DIMENSIONAL DATA BLOUER G 44 J K 10' 23 14 11 -1/2 13 -V4 12' 323 14 13 -9/16 T"J -3/4 PITCHED CURBS ARE AVAILABLE FCR PITCHED ROOFS BPECFY PITCH: IECAMPLE =1/12 PITCF4 • 307 SLOPE ELECTRICAL PACJG4GES No TAG ECP-1 ECP -2 ECP-3 PACKAGE • MICR" UtI t Gabbs! Right LOCATION Hood•1 Unity Gabbs fit: Hood • 2 UU1Ry Cabinet L.R Hood' 3 1Lialt IF.n 111E01 iFai 1 LTght !Fan ROOFTOP STARTER& Maud On In Firs Pans WOE Thers cM aually Corbeled PANS CONIIROLLED TYPE t 1416. VOLT RA E341MNSt On in Fire, Faro OJ1110tf Tnmostaticeily Controlled 134lelist On In Pre, Fan, 05A9ff T.nlostatiatly Controlled 0300 0333 0.150 0.130 4.1 2.1 4.1 2.1 88 Wall Plant Box i L14* iFan Bthaust On In R+e, Fen OWE ThelMOStatfally Calrelled 6L1YNHst 0300 0333 =MEAL PHONE MOEE Jos wax enrearaa -b•ss as ERMINE IIITIMOU purr JDs Nsmlt rS.m Metal sr CONTROL INPUT 1201060 H1-1.0E N1 -$IWTW . TEA Bpi - DO NDF ET RE 10 SHUN 7RP imAIIFR 3 W/ 1 Ddlalue Tory 1 hippy Fa4 m kdlo y FM, p t Corralled. 17.0, mow wwH " we spur Isom N2- H5-L!� N2- Ne- IEUINAL I M spt nip mow PER QAMO 1S platanutzseensmiliaffiamivonifillIMEMIls Nair Typo PIM.l ) & 10-1110 • TM LS 4T sI Imp Swig. • ROB LIS 0.T - Ia>♦ MOE OSUMI OS= RRUINL w. 31111L02,011 eg ILM - 111 -MUM a -.IE a -RIM - - MIN glass MWQ f `~ bwo N UMLD M Flt SUMO OLFRISM Z MOIR( ISM MIT ET ROB 12 x 18 x 8 Box =nem ..- doe /MESS CG MRNR plop JOE MEIER Ntaae ORMN W GONN110L INPUT 120SI4 H1.IJ . N1- 44EUTRAL 124 OCR - DO NOT ME 10 !HUNT 1111A BROKER \:. .' ' a /MS' AZEMETVAI /R its N1•s•i•.'1n•M{ s M. COMM FMMiI. NINALU11ON Jos Ine wnranne uq - sate1S am DAV taM.111e DI EMTI OR or . - JOstNIW MOM CAW t/Y HOOD TO •.. •:.. PANEL POWER FEED FOR CONR>10I8 AND LIGINTI II CMS TEM OM= PUML COMM PALM. r. - • e- n -s� ; HOOD am R , s ... ac au Um MI Me to SR Ss.:: Psi a acme opposter srY.N moll et MID 1>ST0 SWTI'C= TO CONTROL PAUL ND sum sit SEM DUC/ SWITCH STAT 11R OVEN EL W NG FOR FAN mSR TOR FAN G010SO>M. ' n ... 11. WM NIKE .:. o . la= oleTa ... Q + " • W sot • t FEZ WYLI 1 11 808111PGH 120VAC SHUNT TRIP WIRING TO CONTROL. PANEL BMUS WIRING malD -eMa+• WOW MEIN GoIOUCIm TO I Nf>1CJaiM9T. =UM PA Is ERE SOME SEMI : . , 11126-nlIO rf aO a° L �13111 L MIDI, ALaM Tia e m�e esJl s. se: . o it A, see VMS II 1110110S1 s am ,. MSS PPM atesailAls 11 N N tX .: .1=l ' n ■ •11 1 23•Ota, rte, ... K � _ 1 4 ;4 7_ 111p i 4 f�T'"?�I 1411•11 PFC-1:L11 JAN WIRING TO CONTROL r PANE. s HUM asAIIIM'I Was ELECTRIC GAS VALVE =I MIT RIM IIsCTRIC GAS VALVE WITH RESET REu MANUAL RESTY =AY cams REIM ' . ■ n r r as N a s >w y• pap ys W) ( ••■ a a Iii FAN BREAKER PANEL, SEE ^ jams vIl a e+ FAN BREAKER PANEL, . SEE DRAl1IIdG MOTOR •,,.a■ L m ME et j JTP YIN p - 1 MIS US TOOT ■ . sr x Te li1M p 0 o DRAWING . TO ea at = i mrse'..NAZ"'. s miodes MK • SLACK tv1u1All SL•Sus a•�NMr p:= Ims11-N i msa roves =M ARm••MIMS 11S ._ MOTOR TABLE FOR BREAIER SIZING _ A TO rap - 11.r• wan lase - : s T.L__J Te it& ) to as sL IMES - 17.IDISS• I sal ) To sia p ;' • sr ill eAl !s 3r_. 1 IS MIMS Was ( ' ' TO �1 • . :o MI p t � OELINOI: PROMS NONE 1314* FPTA idle t �Fbs. Fan GA/OR lhamosbrEodIr Controlled Odor Inetalsel afire Delia Fred. P•r us awn tar 1umi pm.. : � � oAA1r IN +Ie S -Sit 111/1111110 0 ea moo" 00'° tr 02, Mar 7yss PI MFI MP na TORS .i -lien 1. ns SS II - 1I My Swift p 1 US S.I T 111 Aq IGOE - - 1R N S MRS JMrSE11 -.KM -. s -SD10e a -R. a -.w EMI ORR -a alit R -m i MO . IS MS MOM MD Mar 12x18x8 Box JOE tMIES•ryaOyGle- Sr.W.Yi OTSMSO EWER map JOS NMI* ram IMAM er . CONTROL IIFUT 1200C HI-LI0, Ni- NQnRN. TEA DKR - DO NOT MITE 10 SIIMT TRW BREAKER War Fbltwlldlaa Wit H� rat 71t•rttlosmlbalpr Controlled. AL FMSS tat Imo Nig 11•110 Ws � •Mrs WI MD VIM= IBM Mie IsE5 4111E Ua1T INPUT 20M 112-1115.41112, N2- EIS- NEUTW TEA Mt QAx 140011 PER GICUld R Ndr hypo HT[7M.>! iti SONS aft-MM • LOS Ls 41 Wimp Sq-SSA 11 0 61, S.T - Ns* Jl• N°a°° a 1IRML w N . MILD= R -MUM s -MUA- a -sta a -•w OR - RIM alrt PARE le - Rr .Jr - aie'iie7er -3t a•.otw 'iii'KiRMLihi4Wall,11ili'ii ILKUSICAtatia / a-, RS - Olt M a1. S7 111 AST MIN S M.r 2 x 18 x 8 Box 1 -` conve. own. NSTVJA1104 AmNAMammaseO+W -•amrim PA= -.... /sl.ae tOPMEM02!ER Sail• : JOM•RlJeI MI MI 011114111 Of HOOD TO CONTROL PANEL POWER Flom TOR COITSOIS AND LIGHTINI Gem. Mai 131120011 PAMEL 071711106 PAM OM r. - • -s� ; f'"' CND • Mil Midi sal ha Si mdal ash IS of "' r•o■tol t>r MI ,rt to Ur Sul sod =SW pre .rise . 7/ 6113 THUD SWITCHES TO CON'T'ROL PANEL NI no ME MEM DUCT 8 E B.�s Lill E O• u EEL TOR FAN ' ... cmmTHEIL .:. la= oleTa ... Q + " • W sot • HseR. 1 MRS STSl'J01 ]HCROSE res 120VAC SHUNT TRIP Wfa To CONTROL PANTS. HRaAXIIB WHIM 11126-nlIO rf aO a° L �13111 L MIDI, ALaM Tia e m�e esJl s. se: . o GY1>M. PAEZ;. • ASCES PM i. S. • mils 1 orM• ' s... atesailAls _: N tX .1=l ' n ■ •11 1 23•Ota, ... MR NW PFC-1:L11 FAN 11RDIG TO CONTROL is PANEL • „- wag ds Was IIsCTRIC GAS VALVE WITH RESET REu RESET REPAY Comm. PUN. ^ � •; • „, . 1• 1 FAN BREAKER PANEL, . SEE DRAl1IIdG MOTOR •,,.a■ L m ME et - 0 ■ . •� Te li1M p 0 o . a MIMI 11S ._ _ A : �.,• �•; . : s T.L__J Te it& ) to as sL IMES - 17.IDISS• I sal ) To sia p b TABLE FOR BREAKER LTG 1 IS MIMS Was nR SLAIa SCIMI 711 IL seise Of .11101f 0 1a�ws ' '"+. ` �1 :o MI p '" M t I•MAeM =RIM PROM PAO= JOS HMNESM,MYM/Clr- s•sNN.4 tJRMNE HUMBER J■.p JOS N.M I Ms I NMN BY -' CONTROL. INPUT 1201114 H1 •IJNE. Ni- oEUiRAI. IM BI - 00 NOT WIRE 70 SHUNT 1TIP BREWER 10 LJEHe INPte 120•0 I2-H -Lip'. to- Ne- i.U1M. ids IKR (IMX 1�ROOW PER CIRCUIT) sso -. 1tentT 's- 6O°ft 7Mmmtddbey ***regal appeal*. (Ora where Maud Mead. lalgrgia Mt" un SOS Iwo Rota Mrs Mufti 11. W •••• 1111101010111111110 NO 0 Line Tp• HMO • Ml Nets Si-1 ai ! us SS S is Ale Iq.4•Ie 1 US UNIT 111 1•q MRS SSE CODE OMMI eeDe1L tss. SUMS RAIL tR -1R1_ R.- ME a -sr R - R1R Rtt- aallwgl.tR p -0M ■/p REVIEWED FOR - NUR ar of 1 CE"' NM.7RY w. Mar COMPL£�:CE" s12x18x8Box MAR 2 2 2010 City of Tukwila BUILDING DIVISION j RECEIVED MAR 10 2010 PERMIT CENTER EXHAUST FAN AND D SUPPLY FAN DETAILS AND SPECIFICATIONS SCALE NTS ELECTRICAL DETAILS AND SPECIFICATIONS ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHT: NADEL RETAIL ARCHITECTS, LLP. ALL RIGHTS RESERVED. B.D. SUBMITTAL: 00 -00 -00 SCALE NTS B.D. SUBMITTAL: 00 -00 -00 B.D. SUBMITTAL: 00 -00-00 4 NHOEL RETflII Nadel Retail Architects, LLP 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F. 310.826.0182 www.nadelarc.com CONSULTAN MECHANICAL BUILDING SYSTEMS ENGINEERING SOUP :RMARjKIE 0 tJi CAPTIVEAIRE 1< V l z REVISIONS: 1 1 03 -01 -2010 0 DATE JOB NO. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit. Plans` Checklist MECH -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Supermarket Seafood City uP Date 1/7 /2010 : The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code (yes, no, n.a. ) Section Component Information Required I Location an P Plans rtment Building Department a. Notes HVAC REQUIREMENTS (Sections 1401 -1424) Jeff Pollock C.E.A. # NR 08 -05 -539 1411 Equipment performance = yes.. 1411.4. Pkg. elec, tits.& clg. List heat pumps on schedule x -i : - yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency x -1 AHP48D n. a. 1411.1 Combustion htg. . Indicate intermittent ignition, flue/draft damper & jacket loss - - - Heat Pumps . Ceiling 1412 HVAC controls yes 1412.1 :. Temperature zones indicate locations on plans x -2 3.8 COP yes 1412.2 Deadband control indicate 5 degree deadband minimum x -4 600 n. a. 1412.3 Humidity control < Indicate humidistat FC -5 York yaS 1412.4 Automatic setback Indcate thermostat with night setback and 7 Jiff. day types M -4 -- 3.44 COP Yes 1412.4.1 Dampers !ideate damper location and auto. controls & max. leakage x -4 15000 h. a. 1412.4.2 Optimum Start Inc cate optimum start controls - _ _ yes 1412.5 Heat pump control - Indicate microprocessor on thermostat schedule M -4 _ M -1 n.a. 1412.6 Combustion htg. : Indicate modulating or staged control - - yes > 1412.7 Balancing Indicate balancing features on plans M -1 . 92.4 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas M -4 - - - yes 1422 Thermostat interlock Indicate thermostat interlock on plans x -4 92.4 n.a- 1423 Economizers Equipment schedule - - . 93.0 93.0 1413 Air. economizers 0.a. 1413.1 Air Econo Operation Indcate 100% capability on schedule - - 94.1 n.a. 1413.1 Wtr Econo Operation indicate 100% capacity at 45 degF db & 40 deg F wb - - 93.0 n.a. 14132 Water Econo Doc Indicate clg load & water econoe & dg tower performance - - 94.1 n.a. 1413.3 Integrated operation Indicate capability for partial cooling - - - 94.5 n. a. 1413.4 Humidification Indicate direct evap or fog atomization wl air economizer - . - 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary : M -4 94.5 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M -4 a. a. 1415.1 Piping insulation . Indicate R -value of insulation on piping M -4 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan x -4 yes 1416.22 -3 Sys.Bal & Func.Test Indicate alt and water system balancing & functional testing x -4 yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training H -4 yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M -4 yes 1434 Separate air sys. Indicate separate systems on plans x -1 'Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, effidency, cfm, hp, economizer SERViICb WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank M -4 yes 1442 Shut -off controls Indicate automatic shut -off 61-4 yes 1443 Pipe Insulation indicate R -value of insulation on piping x -4 n. a. 1452 Heat Pump COP Indicate minimum COP of 4.0 - - A. a. 1452 Heater Efficiency Indicate pool heater efficiency - - - a. a. 1453 Pool heater controls Indicate switch and 65 degree control - - - a. a. 1454 Pool covers Indicate vapor retardant cover - - - a. a. 1454 Pools 90+ degrees Indicate R -12 pool cover - - - circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary 2006 Washington State Nonresidential Energy Coda Compliarxe Farms MECH -SUM Revised July 2007 Project Info ProjectAddress Seafood City Supermarket Date " 1/7/2010 Capacity2 mum 1368 Southcenter Blvd- For Building Dept. Use • SEER or EER Tukwila, Washington Applicant Name: Jeff Pollock C.E.A. # NR 08 -05 -539 Applicant Address: 25852 McBean Pkwy # 513, Valencia, CA 91355 Applicant Phone: 661.714.0133 Project Description Briefly describe mechanical system type and features. s Includes Plans Install Split System Heat Pumps Within Existing Tenant Space As Part Of Tenant improvements. Fan Coils In Ceiling and Condensing Units On Structural Members On Roof. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option 0 Simple System ® Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the 1 plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID ` Brand Name.' Model No.1 Capacity2 mum Total CFM OSA CFM or Econo? • SEER or EER IPLV3 Location FC -1 York AHP36C 36000. 1200 120 13.00 3.4 COP Ceiling FC -2 York AHP48D 48000 1600 160 13.00 3.8 COP Ceiling FC -3 York AHP48D 48000 • 1600 160 13.00 3.8 COP Ceiling Fc -4 York AHP183 24000 600 50 14.00 3.44 COP Ceiling FC -5 York AHP188 24000 600 50 14.00 3.44 COP Ceiling EAC-1 SAC -2 Existing. Thane SFHC -0304 - 360000 15000 1500 Existing 332000 Existing Heating Equipment Schedule Equip. ID Brand Name1 • Model No.1 Capacity2 Btu/h Total CFM OSA cfm or Econo? input Btuh Output Btuh Efficiency4 HP -1 York THG036 36000 1200 120 36000 28000 3.4 COP HP -2 York TEGD48 48000 1600 160 48000 34000 3.8 COP HP -3 York '173G048 48000 1600 160 48000 34000 3.8 COP HP-4 York YZB02411 24000 600 50 24000 20000 3.44 COP HP -5 '. York .. Yzs02411 24000 600 50 24000 20000 3.44 COP uH =1 Raznor tiDAP -400 400000 400 400 400000 332000 83% AFUE Fan Equipment Schedule Equip. ID Brand Name1 Model No.1 CFM sp1 HP/BHP Flow Controls Location of Service SP -1 ' Greenheck SAF- 110 -L G-QD 1500 0.50 0.50 Feld assem. sys. : Hood #1 SF -2 Greenheck SAF- 112- 124DG -Q0 3550 0.50 1.50 cv Hood #2 SF -3 Greenheck SAF -II* -LMDG -QD 7500 0.50 5.00 C+T • Hood #3 SF -4 - Greenheck SAF- 110- 1110G -QD 1445 0.50 0.50 CV Hood #4 EF -1 Greenheck CRfZ- 161 -7G-QD 1950 1.00 0.75 CV • Hood #1 EF -2 Greenheck CBE- 240HP -L14GD • 4700 • 1.00 1.50 CV Hood #2 1if available. 2 As tested according to Table 14 -1A through 14-1 G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed NS). 2006 Washington State Nonresidential Energy Code Compliance Form. Mechanical - Complex 2006 Washington State Nonresidential Energy Code Compliance Systems Checklist MECH -COMP Forma Revised July 2007 Project Address Seafood City Supermarket: Date 1/7/2010 The following additional information is necessary to check a mechanical permit application for a complex - mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH - CHIC checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate speditcations alone is NOT an acceptable alternative: For Building Department Use Applicability (yes, no, n.a.) • Code Section Component - Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY a. a. 1431.1 Feld assem. sys. : Provide calculations - Greenheck yes 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 11-1 Hood #4 n. a. 1432.2.1 Air system reset Indicate automatic reset 1.00 3.00 n.a.- 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves - 110 n: a. 1433 Air Economizer Indicate economizer on equipment s e e or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. - - - Greenheck n. s. - 1433 Wafer Economizer Exception water economizer and provide calculations if 1433 Exception 2 is utilized Market Toilet y� 1434 Separate air sys. indicate separate systems on plans M -i 0.13 no 1435 Simul. tits. & dg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified _ - 89.5 • . n.a. 1436 Heat recove ry indicate heat recovery on plans; complete and attach heat recovery calculations _ _ 90.2 yea 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency M -1 91.0 n.a. .1438 Variable flow sys. indicate variable flow on fan and pump schedules 91.0 yes 1439.1 Kitchen Hoods indicate uncooled and unheated make -up air M -i 92.4 n. a. 1439.2 Fume Hoods Indicate VAV, unheated/uncoated or heat rec. makeup - - - no is circlet! for any question, provide explanation: Decision Flowchart Start Here 1' Section 1411.1 Equipment Efficiency Sall Meet Tables 114-1A through 14-16 Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Fuel F input ? 225,000 Btuh? la d.Assembl -. Equipment? Air System Serving Multiple Zones? city of HWN HeaingSysterm> ,000 Btuh 1411.1 Intermittent Ignition Device & Power Vendng or Damper. If input? 225,030 Stull then 1412.8 Modulating or Staged Combustion Controls Required 1411.10.75% Maximum Jacket Loss I _ I Seaton 1431.1 Calculations of Total 1 1 On-Sae Energy Input 1 & Ouput Required Section 1432.2.1 Supply Air Reset Controls Required Yes Section 1432.22 Hot Water Supply Temperature Resat Required (continued on back) 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical - General Requirements` 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1 G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and on-fired forced air furnaces with input ratings> 225,000 Btufh (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (110) and have either mechanical draft (including power venting) or e flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shalt have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Coofing equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991_ Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packs equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump.: Exception: Unsteffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1trols 1412412 .Con1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within thezone. At a minimum, each floor of a building shall be considered as a separate zone.' - 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. • 1412.4 Setback and Shut-Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time fora power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btuih) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 nutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fads to open upon toss of power) dampers; These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. lira itty ( nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stones in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design Occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.S stems with energy recovery ry complying with Section 1436. 2. Muttiple-zone systems without direct - digital control of individual zones with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling: Water economizers shall be capable of providing the total concurrent cooling load served by the connoted; terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40°F wet -bulb and below. For this calculation, ail factors including solar and Internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. Design cooling load to be provided by economizer at this outside air condition.' Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413,3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 atw t and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. : Water - tooted water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions 1. Health care facilities where WAC 246 - 320525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 8tu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions far air recircutation to the central supply fart. 4. Nonadiabatio humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 12 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 12 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 Inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 Inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include Insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut-off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical. Summary 2006 Washington State Nonresidential Energy Code Compliance Forms MECH =SUM Revised Jury 2007 Project Info : EF CAE < 50 gat storage 0.58: 0.71 50 to 70 gal storage 0.57 0.71 , 70 gal storage 0.55 0.70 1412.8 Ventilation Controls for High -Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design Occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.S stems with energy recovery ry complying with Section 1436. 2. Muttiple-zone systems without direct - digital control of individual zones with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling: Water economizers shall be capable of providing the total concurrent cooling load served by the connoted; terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40°F wet -bulb and below. For this calculation, ail factors including solar and Internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. Design cooling load to be provided by economizer at this outside air condition.' Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413,3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 atw t and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. : Water - tooted water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions 1. Health care facilities where WAC 246 - 320525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 8tu/h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions far air recircutation to the central supply fart. 4. Nonadiabatio humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 12 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 12 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 Inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 Inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include Insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut-off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical. Summary 2006 Washington State Nonresidential Energy Code Compliance Forms MECH =SUM Revised Jury 2007 Project Info : Project Address Seafood City Supermarket Date 1/7 /2010 Capacity2 Btu/h 1368 Seuthceater Blvd. For Building Dept. Use SEER or EER Tukwila, Washington Applicant Name: Jeff Pollock C.E.A. # NR 08- 05-539 Applicant Address: 25852 McSean Pkwy # 513, Valencia, CA 91355 Applicant Phone: 661.714.0133 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Exhaust Fan Specifics Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option 0 Simple System ® Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name1 1 Model No.1 Capacity2 Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location Greenheck CUBE.- 300 -LMDG 10000 1.00 _ 5.00 CY Hood #3. EF-4 Greenheck CUBE-161-1240G 1700 1.00 0.75 CV Hood #4 Er -5 Greenheck GB -300 7100 1.00 3.00 CV Sales Area EF -6 Greenheck SP -B110 110 0.25 • 0.08 CV Valerio's EF -7 Greenheck GB071 400 0.50 0.25 C't Market Toilet EF-8 Greenheck CSP -5150 148 0.25 0.13 CV Office 89.5 89.5 89.5 - 89.5 • . 91.0 90.2 Heating Equipment Schedule Equip. iD Brand Name' Model No.1 Capacity2 Btu/h Total CFM OSA cfm or Econo? Input Mutt Output Btuh Efficiency4 Greenheck CUBE.- 300 -LMDG 10000 1.00 _ 5.00 CY Hood #3. EF-4 Greenheck CUBE-161-1240G 1700 1.00 0.75 CV Hood #4 Er -5 Greenheck GB -300 7100 1.00 3.00 CV Sales Area EF -6 Greenheck SP -B110 110 0.25 • 0.08 CV Valerio's EF -7 Greenheck GB071 400 0.50 0.25 C't Market Toilet EF-8 Greenheck CSP -5150 148 0.25 0.13 CV Office 89.5 89.5 89.5 - 89.5 • . 91.0 Fan Equipment Schedule Equip. ID Brand Name1 Model No.1 CFM • SP1 HP/BHP Flow Controls Location of Service EF -3 Greenheck CUBE.- 300 -LMDG 10000 1.00 _ 5.00 CY Hood #3. EF-4 Greenheck CUBE-161-1240G 1700 1.00 0.75 CV Hood #4 Er -5 Greenheck GB -300 7100 1.00 3.00 CV Sales Area EF -6 Greenheck SP -B110 110 0.25 • 0.08 CV Valerio's EF -7 Greenheck GB071 400 0.50 0.25 C't Market Toilet EF-8 Greenheck CSP -5150 148 0.25 0.13 CV Office 1tf available. 2 As tested accord ng to Table 14 -1 A through 14-1 G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energ Code Com • Rance Form 2006 Washington Stato Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Seafood City Supermarket Date 1/7/2010 Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). For Building Department Use Motor No. or Location HP Type (open/closed) Description of Application or Use Synch. Speed Min.Nom. Full load Efficiency FC -1 1/2 open Kitchen 1200 ea. OS FC -2 1/2 open Dining 1200 80.0% FC-3 1/2 °Pen Pharmacy 1200 80 0% Fc -4 1/3 open Retail 1200 80.0% FC-5 1/3 open Retail 1200 80.0% sF -1 1/2 open Kitchen Hood # 1 1200 80.0% SF -2 1- 1/2 Kitchen Hood # 2 1200 84.0' sr -3 5 Kitchen Hood # 3 1200 87 5% SF -4 1/2 Kitchen Hood .# 4 1200 80.0% EF -1 3/4 Kitchen Hood # 1 1200 80.0% EF -2 1- 1/2 Kitchen Hood # 2 1200 84.0% EF-3 5 Kitchen Hood # 3 1200 87.5% EF -4 3/4 Kitchen Hood # 4 1200 80.0% EF -5 3 Sales Area 1200 86.5% Ef -6 1/12 Valerio's 1200 84.0% EF -7 1/4 open Market Toilet 1200 80.0% EF -8 1/8 open Office 1200. 80.0% Minimum Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 Open Motors Closed Motors 3,600 1 1,800 1,200, 3,600 1,800 1,200 Efficiency (%) Efficiency (%) 82.5 80.0 ' 75.5 82.5 80.0 82.5 84.0 84.0 82.5, 84.0 _ 85.5 84.0 - 84.0 • 85.5 84.0 • 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 _ 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 - 89.5 • . 91.0 90.2 90.2 91.0. 90.2 90.2 _ 91.0 91.0. _ 90.2 91.0 902 91.0 91.7 ° 91.7 91.0 92.4 91.7: - 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0. 93.0 92.4 93.0 93.0 92.4 93.0 . 93.0 93.0 93.6 916 93.0 93.6 • 93.6 93.0 94.1 93.6 93.0 ' 94.1 93.6 ' 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- lA or 14-1B) . 3. Motors that are an integral part (Le. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (Le. if the only U.L. fisting for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. 2006 Washington State Nonresidential Energy Code Compliance Form 1412:4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from tne exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14-5 requirements. Other ducts and plenums shall be thermally insulated per Table 14.5. Exceptions: 1, Within the HVAC equipment 2. - Exhaust air ducts not subject to condensation, 3. Exposed ductwork within a zone that serves that zone. 1416 Piping Systems in Table 14-6. 1416.1 Insulation: Piping be thermal insulated n accordance with Ta ipi g shad N Exception: Piping installed within unitary HVAC equipment. Water P P i P es outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51-26) 1418 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association. for complete text end guidelines for building completion and commissioning requirements.) air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.6 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g -, LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu h shall have modulating or staged combustion control 000 _ EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have g PPly h a means for balancing, including but not limited to, dampers; temperature and pressure test connections and balancing valves.' CODEIEVlIED FOR COMPLIANCE APPROVED MAR 2 2 2010 City of Tukwila BUILDING DIVISION RECEIVED MAR 10 2010 PERMIT CENTER NHOEL RETHIL Nadel Retail Architects, LLP 1990 South Bundy Drive Fourth Floor Los Angeles, CA 90025 T. 310.826.2100 F. 310.826.0182 www.nadelarc.com CONSULTANT: 0Z Z E _ W 5 Z Z U_ W Z Q = w O f- W Fax: 818 - 348 -0111 tom1assoc@aol.com 0 w 3 re o. oG i- V tad W Z W DRAWING TITLE: REVISIONS: 1Q 03-01 -2010 Q O 0 O O A t� DATE 12.17.09 JOB NO. 09293 SHE • MB M -6