Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M10-018 - ZONAR
ZONAR 18200 CASCADE AV S M10 -018 Parcel No.: 7888900170 Address: Suite No: City4Rf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 18200 CASCADE AV TUKW MECHANICAL PERMIT Permit Number: M10 -018 Issue Date: 02/26/2010 Permit Expires On: 08/25/2010 Tenant: Name: ZONAR Address: 18200 CASCADE AV SUITE 100 , TUKWILA WA Owner: Name: RIVERPOINT TWO LLC Address: 1100 OLIVE WAY #1005 , SEATTLE WA Contact Person: Name: BART SLOAN Address: 1020 S 344 ST , FEDERAL WAY WA Contractor: Name: S B QUALITY AIR LLC Address: 4909 ORCA DR NE , TACOMA, WA Contractor License No: SBQUAAL044MA Phone: Phone: 206 - 779 -8144 Phone: 253 - 927 -6399 Expiration Date: 06/29/2010 DESCRIPTION OF WORK: ADD FLEX DUCT, 26 SUPPLY AND 14 RETURN AIR GRILLS TO EXISTING EQUIPMENT Value of Mechanical: $12,000.00 Type of Fire Protection: Fees Collected: $326.06 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND QUANTITY Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 26 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment0 * *continued on next page ** doc: IMC -10/06 M10-018 Printed: 02 -26 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M1O -018 Issue Date: 02/26/2010 Permit Expires On: 08/25/2010 Permit Center Authorized Signature: Date: c:272-/a% I hereby certify that I have read and examin-d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, hether specified herein or not. The granting of this construction o Signature: Print Name: t s � pres of wo to give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this mechanical permit. Date: ?-07C31/10 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M10 -018 Printed: 02 -26 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 7888900170 Address: 18200 CASCADE AV TUKW Suite No: Tenant: ZONAR PERMIT CONDITIONS Permit Number: M10 -018 Status: ISSUED Applied Date: 02/10/2010 Issue Date: 02/26/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10 -018 Printed: 02 -26 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein; r not. The granting of this permit not presume to give a;,l'ority to violate or cancel the provision of any other work or local laws regulating construction or the - - ' ormance • w • rk. / / Date: per/ Signature: Print Name: doc: Cond -10/06 M10-018 Printed: 02 -26 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Permit No. M ( 2� Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 7 g& 6qo - 0 ( 70 Site Address: / F.? ©Q ea6 Cade 4v( 3 Suite Number: /6 o Floor: 2.C2V6� Tenant Name: New Tenant: ❑ Yes ❑..No Property Owners Name: .g+t U ` l-tt L6 CD / /OxJ alv�UC- c a y .L yao .5m /e Mailing Address: City W 9re Zip 4� State CONTACT PERSON - Who do we contact when your permit ii ready to be :issued Name: Mailing Address: (Ooh' �, �� V9/74- , 4- E -Mail Address: Ei\ J L z,/ /% y Telephone: ;c6- / t4-y y tdo c3 try State Zip l (�C0 Fax Number: g5:5— 5 3 —��T MECHANICAL CONTRACTOR INFORMATION • Company Name: 6-6 Cc i ( L-Z-- Mailing Address: ( OD, C 5,'Y1-4- Gda '.6776Z9 Contact Person: E -Mail Address: Contractor Registration Number: cze A/ S Qc,,t 7k4 L-0 Ciry State (% Zip Day Telephone:' ' 77 "77 7 C' ' Fax Number: 2�_? � 9 2 d 7 a 4/4/111,4Expiration Date: ^ 'c 7 ARCHITECT. OF RECORD - All plansmust be wef stamped by. Archifectof Record s,.. Company Name: Mailing Address: State Contact Person: E -Mail Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:Wpptications\Forms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1.2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 • • Valuation of Project (contractor's bid price): $ 12‘x=0,6-7--s Scope of rk (ple.se arov'a - detailed information): i _ f ( ? eiceKkt 4 / 7 -('! �u( /xi,. Use: Residential: New ❑ Replacement ❑ Commercial: New der Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: • Qty Boiler /Compressor: . Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser y/1 ((// 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator – Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator– Comm/Ind Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE ' ' D AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY 0 ' "!i RY B LAW F THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING AGENT: Signature: /�� G Date: L/ int Name: L--1, D Telephone Mailing Address: 1C) —ti/ �T State City Zip Date Application Accepted: „_ c Date Application Expires: �� r jl Staff Initials: t 4 H:1ApplicationsWorms• Applications On Line12009 Applications \I -2009 - Mechanical Permit Applicationdoc Revised: 1.2009 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 7888900170 Permit Number: M10-018 Address: 18200 CASCADE AV TUKW Status: PENDING Suite No: Applied Date: 02/10/2010 Applicant: ZONAR Issue Date: Receipt No.: R10 -00231 Payment Amount: $326.06 Initials: WER Payment Date: 02/10/2010 01:48 PM User ID: 1655 Balance: $0.00 Payee: S B QUALITY AIR TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11927 326.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 260.85 000.345.830 65.21 Total: $326.06 PAYMENT RECEIVEF) doc: Receiot -06 Printed: 02 -10 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit A40'CI PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: +c1 — Type of Inspection: }� D uc., - ,..-7:41j u l'it"/ , bii Address: 00 ` 2 --d 6 (5j1 Ae4=_- Date Callef(,,, h. -mv, ? Special Instructions: /, Date Wanted: _ (� -10 aa..m.. 3 Requester: Phone No: )7 /..) �—r 7 ,Q� � CO t q 'o , r—T Approved per applicable codes. EJCorrections required prior to approval. / COMMENTS: Ms 3 ikteA 0" x_t ( 5 eA P Inspe oct' r: 4AA..) Date: .3 _(S - ` 0 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PE to PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -018 DATE: 02 -10 -10 PROJECT NAME: ZONAR SITE ADDRESS: 18200 CASCADE AV X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Blinding Division R. ' D it1. ►D Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 02-11 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROyTING: Please Route Z] Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-11-10 Approved Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople Paer Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S B Quality Air Llc UBI No. 601703761 Phone 0000000000 Status Active Address 4909 Orca Dr Ne License No. SBQUAAL044MA Suite /Apt. License Type Construction Contractor City Tacoma Effective Date 7/1/1996 State Wa Expiration Date 6/29/2010 Zip 98422 Suspend Date County Pierce Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SBQUAAS088MM S B Quality Air &Amp; Sheet Metal Construction Contractor General Unused 7/14/1992 6/5/1995 Archived Business Owner Information Name Role Effective Date Expiration Date Sloan, Bart Partner /Member 01/01/1980 Bond Amount Jones, Clyde Partner /Member 01/01/1980 425978C Jones, Theresa Partner /Member 01/01/1980 Sloan, Linda Partner /Member 01/01/1980 INS CO Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 DEVELOPERS STY & INDEMNITY CO 425978C 05/21/2002 Until Cancelled $12,000.00 06/03/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 OHIO CAS BK053354910 06/05/2006 06/05/2010 $1,000,000.0005 /28/2009 INS CO https://fortress.wa.gov/lni/bbip/Print.aspx 03/01/2010 ` CALij AVENUE. :kUr *P.a•.rmNNW MR.-- w-...wFNIds. ww.F., MOW •.vu..s w: BUILDIN 182100 CASCADE AVE. SOUTH it if BUILDING 2 18200 OA-SCAM AVE: SOUTH LIE)! a'rii„t'A "r: "r Q SITE PLAN 7:117 NO SCALE ABBREVIATIONS ADJ ALT AFF ALUM L ANOD. ACT BLDG. BLK'G. BM BIS CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FE FF FIN FLR FLUOR FOIC ADJUSTABLE 1 ADJACENT ALTERNATE ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING TILE AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FIRE EXTINGUISHER FACTORY FINISH FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR FT FTIC FURN GA GALV GL GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL JAN JB JST JT KIT LF LTG MAIL MAX MECH MED MEZZ MFR MISC MTD MTL N/A NIC NO NOM NTS FOOTIFEET FURNISHED BY TENANT INSTALLED BY CONTRACTOR FURNISH 1 FURNISHINGS GAUGE GALVANIZED GLASS 1 GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MEZZANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP THERMO TYP VAR VCT VEN VERT VWC WI W/0 WC WD ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL VARIES VINYL COMPOSITION TILE VENEER VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD GENERAL NOTES AREA OF WORK THIS PERMIT FIRST FLOOR 9ii VICINITY PLAN NO SCALE FILE COPY Permit No. M \`h -19 Plan review approval is subject to errors and omissions. Approval of construction documents d < S not authorize the violation of any adopts . code or rdinance. Receipt of approved - - 0'rp I . y : s is acknowledged: BY Date:, City Of Tukwila BUILDING DIVISION 1. REFER TO BASIC BUILDING SHELL SPECIFICATIONS AND STANDARDS FOR EXISTING SHELL CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. 2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR, 3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. 5, ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS ANY CHANGE TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL 7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECTS APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECTS APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. 8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. 9. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. D OTHERWISE. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping iv) i1 1: City of Tukwila BUIL NNG DIVISION 11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECTS APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. 12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. 13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE BACK -UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. 15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. 16. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECTS & TENANT APPROVAL SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC. 18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT. 19. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 114" IN 10" -0 ". THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 20. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal ! and may include additional plan review fees . tenant improvement Zonar Corporation 18200 Cascade Avenue South Tukwila,WA PROJECT NOTES TAX LOT NUMBER: ! 7888900170 LEGAL DESCRIPTION: REVIEWED FOR CODE COMPLIANCE APPROVED FE3 19 2010 11 City ° T �+ la BUILDING DI IPION SOUTHCENTER SOUTH INDUSTRIAL PARK LOTS 15 & 17 BEGINNING SW CORNER LOT 17 THEN S 78° 36' 10" E 80 FEET THEN ALONG CURVE TO RIGHT CENTER BEARING N 11° 23' 50" E ALONG A LINE 30 FEET E OF & PLW W/ LINE LOT 17 DISTANCE OF 357 FEET TO TPOB THE CONTG N 11d 23' 50" E ALONG SAID LINE RADIUS 50' ARC DISTANCE 78.54 FEET THRU C/A OF 90° 00'00" THEN N 11° 23' 50" E ALONG SAID LINE 291.25 FEET THEN ALONG CURVE TO LEFT RADIUS 110 FEET THRU C/A OF 62D 57' 52" ARC DISTANCE OF 120.83 FEET THEN N 11° 23' 50" E ALONG A LINE 30 FEET W OF & PLT W LINE OF LOT 17 147.375 FEET TO THE TOP OF RIGHT BANK OF GREEN RIVER THEN ALIGN SAID TOP OF RIGHT BANK OF GREEN RIVER TO THE FOLLOWING COURSES AND DISTANCES S 44° 29' 00" E 96.32 FEET S 59° 43' 00" E 98.00 FEET S 72° 17' 00" E 101.00 FEET S 82° 08' 00 "E 100.00 FEET N 78° 54' 00 "E 99.00 FEET N 68° 34' 00" E 99 FEET N 73° 00' 33" E 97.69 FEET M/U TO W/ MARGIN OF SECONDARY STATE HIGHWAY 2M THEN LEAVING SAID TOP OF RIGHT BANK OF GREEN RIVER ALONG SAID W. MARGIN ON A CURVE TO RIGHT OF THE CENTER BEARING N 47° 33' 20" W RADIUS OF 543.14 FEET ARC DISTANCE 87.08 FEET THRU C/A OF 90° 11' 11" THEN S 51 ° 37' 10" W 131.40 FEET THEN ALONG CURVE TO LEFT ON SAID W. MARGIN RADIUS OF 603.10 FEET ARC DISTANCE OF 423.53 FEET THRU C/A OF 40° 14' 10" THEN S 11° 23' 50" W 23.32 FEE'THEN N 78° 36' 10" W 295.00 FEET TO TPOB - AKA PHASE II OF CORPORATE PROPERTY INVESTORS BINDING SITE IMPROVEMENTS PLAT RECORDING NO. 810421010455 & CITY OF TUKWILA BOUNDARY LINE. ZONE: SITE AREA: CONSTRUCTION TYPE: BUILDING AREA: NORTH BUILDING NO. STORIES SOUTH BUILDING NO. STORIES PARKING REQUIRED: PARKING PROVIDED: CODES USED: TENANT AREA: OCCUPANCY: OCCUPANT LOAD: TENANT: SCOPE OF WORK: C 1 CU 6.58 ACRES V -B FIRE SPRINKLERED 53,625 2 53,625 2 278 STALLS 414 STALLS 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL FIRE CODE 2006 WASHINGTON STATE ENERGY CODE 2006 WASHINGTON STATE BUILDING CODE 2006 PLUMBING CODE 2006 MECHANICAL CODE 2003 ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES 12,120 USEABLE SQ. FT. (FIRST FLOOR) B - OFFICE 100 SQ. FT. /OCCP. 12,120/100 = 121 OCCUPANTS ZONAR CORPORATION INTERIOR TENANT IMPROVEMENT ON THE FIRST FLOOR OF APPROXIMATELY 4,727 SQ. FT. THE WORK CONSISTS OF BUILDING NEW WALLS, DOORS AND OTHER ARCHITECTURAL FEATURES. THE SPACE CURRENTLY HAS A COMPETE SUSPENDED ACOUSTICAL TILE CEILING AND LIGHTING SYSTEM. A PORTION OF EXISTING LIGHT FIXTURES WILL BE RELOCATED AND SOME NEW FIXTURES WILL BE ADDED. A NEW HALLWAY WILL BE CONSTRUCTED TO ALLOW ACCESS TO THIS TENANT SPACE AND FUTURE TENANT SPACES. BUILDING REPRESENTATIVE: ARCHITECT: GENERAL CONTRACTOR: O'KEEFE DEVELOPMENT COMPANY 1100 OLIVE WAY, SUITE 400 SEATTLE, WA 98101 T. (206) 236 -6200 F. (206) 236 -6160 CONTACT: HARPUR DAVIDSON EMAIL: harpur @okeefedevelopment.com LANCE MUELLER & ASSOCIATES 130 LAKESIDE AVE SEATTLE, WA 98122 T. (206) 325.2553 F. (206) 328 -0554 CONTACT: PAUL ENGERT EMAIL: pengert @Imueller.com SMAJIC CONSTRUCTION, LLC 12219 SE 65th STREET BELLEVUE, WA 98006 T. (206) 419 -8090 F. (425) 378 -2593 CONTACT: ADI SMAJIC EMAIL: smajic@msn.com DEFERRED SUBMITTALS 1. PLUMBING WORK UNDER SEPARATE PERMIT 2. MECHANICAL WORK UNDER SEPARATE PERMIT 3. FIRE SPRINKLER WORK UNDER SEPARATE PERMIT INDEX OF DRAWINGS TA1.1 COVER SHEET / SITE PLAN TA2.1 1/16" OVERALL BUILDING PLANS TA2.2 1/8" FIRST & SECOND DEMOLITION PLANS TA2.3 1/8" FIRST & SECOND FLOOR PLANS TA2.4 1/8" FIRST REFLECTED CEILING PLAN TA3.1 WALL SECTIONS / DETAILS / CEILING DETAILS TA3.2 STAIR PLANS 1 SECTIONS 1 DETAILS TA3.3 DOOR SCHEDULE & TYPES 1 INTERIOR ELEVATIONS S1 PARTIAL FOUNDATION PLAN & 2ND FLOOR FRAMING PLAN S2 FOUNDATION & FLOOR SECTIONS RECEIVED FEB 10 2010 PERMIT CENTER MIOOI8 Tukwila, Washington w W LL"I 0 0 z -J 0- W sheet TAI1I Id 111111■111■111111111111111 msm m .... ...___ , _i__ bum 11,,,,imin „onn ,Dirmo,_ Li ri I ....0 Till 11011111111111I1 Ail Illi. 111/ 101,,Ilim.11.11.10...111110 oils 11 I II 1 II Pir`111111LA it 11111 ,„.,„,,„ ,,,,, ...A ____, .., , ..... , ZIE:dir -4:-.1:2111111111111111111 1.121111;1 111111 111111=11111Namifin '11111' Elsormillidliii71111 1111111211"rit12111111 - .....-,.. 'Iiilmo .01 Nil 11111 rtZIESTurairi: II . k ......Mil igiVOIM En il IIIIMII 111111111114 . Nom. M11111111 1 ..., .....1 .. =I mum 1 tqlrff 1".111 irAilli111111 11111111 11111111111111111 Inullamtirroltili71,iii 1E111111 1.4.4.4& ., ..,il ., ., MOMOMMOM ONOMMOM milimmaammommimmmrderl AdorVAN IVY Art mozerm rAraraortear " )014 "1/7 A /77.4/2410 111 4 syr Ara. II I • 1 11111111 10111111 , \A-i-4r A AM Knor A NEE , xErodA.VAN Ar Nr4pwrArar• row, Agr war • r r w. etlimmomm. 7...i IR ME 111111SMDIVIIMIENnen 1 MEW NMI 111 1111 IV RE al ammo mow 10101=== JmIio r IIIIIIMMOMI1141111411MMIMIMINIMMIIIMMI MilkhlOPOViMi:F=1111.1111MMINk.MIMMIMMENNIMMUUM1i • • • r • *WNW 4r411411111111. 1111 hommmmie4M1111 por dAranr • MOW gr ANK Nev ArAn'Er Arir, ---`4•;14,741:1NreAlfeargr :400 „1"...mpral 1 . .. . ill 1 ..............7.7... .......i.....0.....,..: ........w...iii . . 11 111!Illilliiiiiiii---- !! ! til p 11011142.111.6EL iiiiillii II:, fir ...r. .A....171-111ammunamm mom ....," •1_,IF- ,Miliilini11111111111.111111111 111111111111111111111 10111111111111111111 1111111111111111111 11111111111111111111111111111PMEP 1111111 11111; $111111111111Wrr AIR.AlmLo!!!!!anrrill1111411111g 111.111111ir 61111111101111dRIMIIIIIIIII ...... .I.P111111KLEMIlrolll RIME NINE 1111111111111111111111 11111 ILI 111111111111111 11 91111111 IMMISPNIENIMINIIIIIIIIIIIIII 11111 11111:: alumni 1 "Hill. UP IA iiiiiiiingliiiiiiiiiiniiiiinliiiiiiiiiliiiiiiiiii Eli imimal mosommanya 11111111111111111 INN m ago Am mum 1st FLOOR ZONAR SCALE: 1 /8" = 1' O.S.A. REVIEWED CODECCIMPLIANCE APPROVED FEB 1 i 2010 City of Tukwila BUILDING DIViPrAt FRESHAIR DUCT RECEIVED FEB 1 6 2010 mimic C t((, UNIT DESIGNATION THE\I'RM AT FLEX. DUCT TO DUCTBOARD PLENUM TO FLEX DUCT TO DIFFUSER SUPPORTED EVERY 4• (TYP.), JACKET MATERIAL COLOR MUST BE GRAY OR BLACK ONLY. NOTE: SPIN-IN WITH VOLUME DAMPER t SPIN-IN CONFIGURATION VARIES WITH APPLICATION 2. SPIN-IN MUST BE A MINIMUM OF 24" FROM HEAT PUMP. SB Qaulity Air 1020 South 344th ST Suite 201 Federal Way, WA 98003 Main Office (253) 927-6399 Fax (253) 927-6091 MECHANICAL TENANT: ZONAR RIVERPOINT CORP. CENTER N. BLDG. 1st FLOOR DATE: 2/15/2010 DRAWN: E. BENTHIN CHECKED BY: SCALE: 1/8" = 1 SHEET: M4 OF: PROJECT # 2009-81