Loading...
HomeMy WebLinkAboutPermit M10-021 - FORT DENT 1FORT DENT I 6720 FORT DENT WY M10 -021 Parcel No.: 2954900455 Address: Suite No: City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 6720 FORT DENT WY TUKW MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M10 -021 03/02/2010 08/29/2010 Tenant: Name: FORT DENT 1 Address: 6720 FORT DENT WAY , TUKWILA WA Owner: Name: JOHN C RADOVICH LLC Address: 2835 82ND AVE SE #300 , MERCER ISLAND WA Contact Person: Name: CHRIS LEE Address: 7717 DETROIT AVE SW , SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU Phone: Phone: 206 -768 -4266 Phone: 206 - 768 -4180 Expiration Date: 12/31/2010 DESCRIPTION OF WORK: REPLACE EXISTING (1) ROOFTOP UNIT WITH NEW Value of Mechanical: $19,800.00 Type of Fire Protection: Fees Collected: $424.06 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat /Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 1 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment0 * *continued on next page ** doc: IMC -10/06 M10-021 Printed: 03 -02 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M10 -021 Issue Date: 03/02/2010 Permit Expires On: 08/29/2010 Permit Center Authorized Signature: Date: ( 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o performance • work. I am authorized to sign and obtain this mechanical permit. Signature: / Date: 4--/C.) Print Name: UtrLt This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M10 -021 Printed: 03 -02 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 2954900455 Permit Number: M10 -021 Address: 6720 FORT DENT WY TUKW Status: ISSUED Suite No: Applied Date: 02/12/2010 Tenant: FORT DENT 1 Issue Date: 03/02/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M10 -021 Printed: 03 -02 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond-10/06 M10 -021 Printed: 03 -02 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: S /21/ 0 ordinances governing or local laws regulating doc: Cond -10/06 M10 -021 Printed: 03 -02 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION` Site Address: Mechanical Permit No. tit 0' Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 6720 FORT DENT WAY TUKWILA, WA 98188 Tenant Name: FORT DENT 1 Property Owners Name: JOHN C RADOVISH LLC King Co Assessor's Tax No.: 2954900455 Suite Number: Floor: .00 New Tenant: ❑ Yes 0 .. No Mailing Address: 6720 FORT DENT WAY TUKWILA City WA 98168 State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: CHRIS LEE Day Telephone: (206) 768 -4266 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City Fax Number: E -Mail Address: CHRIS.LEE @MACMILLER.COM State (206) 768 -4267 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip Contact Person: CHRIS LEE Day Telephone: (206) 768 -4266 E -Mail Address: CHRIS.LEE @MACMILLER.COM Fax Number: (206) 768 -4267 Expiration Date: 12/31/2010 Contractor Registration Number: MACDOFS980RU ARCHITECT OF RECORD - Alt plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City Contact Person: CHRIS LEE E -Mail Address: CHRIS.LEE @MACMILLER.COM H:\Applications\Forms- Applications On Line\2009 Applications \1-2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Day Telephone: Fax Number: State (206) 768 -4266 (206) 768 -4267 Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ 19,800 Scope of Work (please provide detailed information): REPLACE EXISTING (1) ROOFTOP UNIT WITH NEW Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ® Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <IOOK BTU Air Handling Unit >10,000 CFM 1 Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A THORIZED AGENT: Signature: Print Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW Date: 02/11/2010 Day Telephone: (206) 768 -4278 SEATTLE WA 98106 City State Zip IDate Application Accepted: Date Application Expires: Staff Initials: ifte n:\Applications \Forms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1-2009 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Applicant: FORT DENT 1 RECEIPT Permit Number: M10 -021 Status: PENDING Applied Date: 02/12/2010 Issue Date: Receipt No.: R10 -00251 Payment Amount: $424.06 Initials: WER Payment Date: 02/12/2010 02:12 PM User ID: 1655 Balance: $0.00 Payee: MACDONALD MILLER TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2383 424.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 339.25 000.345.830 84.81 Total: $424.06 PAYMENT RECEIVED doc: Receiot -06 Printed: 02 -12 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: ii_ 7�u` �- Type of Inspecti B l A r. `'C Address: to rate Called( j il IL\ 5.,� Special Instructions: 51).-"Y C,, lr op---(/ Date Wanted: /v (o Requester: Phon 6 r 5'7 I -3q34 /Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 'MPrti 1-4 r( — .cs» )t_ e Stc` RAk 0 J(�x\ rl--4?2_2deA .t *" (i r-c OP. _ Ai ( M Gt� r--1 ■ •n'` -1' e 4� ()LAT ., A"f ), p pr d,Jr 4-- C t f ikA.,'t-- ( , 6 in./t f\ e) E_ Af A D A 0 if'. Ply( T)A ef Insp¢ctor: Date: I — 1 — 1 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: si; a;; �: 7£ an? t�' Wii�Sr5'Wys- ':�>'�+�:•1M�r:: .C�;.:a�^ .. , xY2Ka: YU`= ��rY. s:. E�°. �; E:. 2•`. x:�.�+'aw�i:�A+u.- �- rv.^uwr,l� tiF,,;;�::a.¢e.�. ��ior::e +�c..5.rrr;;e�sr �t��?.;,:.v:.�MZ+�-a�w a I INSPECTION NUMBER INSPECTION : RECORD Retain a copy with permit PERMIT NUMBERS C TY OF TUKWILA FIRE DEPARTM, ENT 444 Andover Park East, Tukwila, Wa: 98188 Ya -` • ` l 206-5754407 Project: G • 014.13 Type of Inspection: Address: 6.72.0 A..�i -Dt.4' 4.I! Suite #: 04/0 > • Contact Person: P)0, [, Special Instructions: r Phone No.: Z ,pG — 730— 2.72- [proved per applicable codes. ric Corrections required prior to approval. COMMENTS: AleVe 5r74y4 d pro -et . = -► .1 -- 402 V Needs Shift Inspection: 014.13 Sprinklers: Fire Alarm: jai Hood & Duct: Monitor: r Pre -Are: - Permits: Occupancy Type: Inspector: 014.13 Date: 115 f / jai H rs.: / ee$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Lincoln Center Business Park 555 116th Ave. NE, Suite 150 Bellevue, WA 98004 Phone 425.644 -6400 Fax 425.644 -0463 FILE COPY FORT DENT ONE MECHANICAL UNIT SUPPORT 6720 FORT DENT WAY TUKWILA, WASHINGTON 98188 STRUCTURAL CALCULATIONS FEBRUARY 03, 2010 JOB NO: 156 -1002 1 EXPIRES 2-7 --Z.,i) ` M REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2010 City of Tukwila BUILDING DIVISION RECEIVED FEB 12 2010 PERMIT CENTER ti ).> 31 = 7 A x • PARTIAL ROOF FRAMING PLAN NOTES 1) CONTRACTOR TO VERIFY ALL SIZES, DIMENSIONS, AND LOCATIONS AT FIELD. 2) .CONTRACTOR TO VERIFY ALL EXISTING ROOF FRAMING MEMBER SIZES. 3) CONTRACTOR TO VERIFY MECHANICAL UNIT SIZE, WEIGHT AND LOCATIONS. jecVSoblect oy Dale Sheet No. 1 )1,r) (A) — sG,eE►./_f °��e, /%e-c' v),2 (G�-71 J 000iG■" j'.Dg - i'G�GOY f"" TiVG-} 1 )ix GO' >4 /l g-x X17 ∎,✓Jex 3' 7 JX o ii�C /�, l/�✓��1 �/f��OoiGj Date Noo .loo rb. ROOF LOADS: DEAD LOAD: B.U. ROOFING 2 PSF MTL DECKING 2.2 BEAMS 6' o.c. 6 SPRINKLER 1.5 INSULATION 1 PURLIN 0 CEILING 1.5 MISC. 0.8 15 PSF LIVE LOAD: SNOW 25 PSF TOTAL LOAD: 40 PSF MECHANICAL UNIT DATA: RTU -I = 15,226 Ibs Project Sub ec+ �G1y /i•,/9..-- s '//?may Date 4+eet N3/ Job No �x3 >rx 7;i3) , 9 1.77 ) °'x)Z °- �✓�4 �C-3� _._ �p,ii��% %lam % o , 1� �� i! jr a V 4 5.7". egx)):s ■ z94 o, eZ 74. 272 o, /moo Of -oz 37X-- 37 G` ),G7 J� 3 38 ,x2;,57oof. >C 3ZS Doe -2g —/0 Sheet 214 .bD'Nn. LATERAL DESIGN:(IBC 2006, ASCE 7 -05) (A) WIND - BASIC WIND SPEED = 85 MPH (FIG. 6-1, ASCE 7 -05) EXP. "B" lw = 1.0 Kd = 0.9 (TABLE 6-4, ASCE 7 -05) Kz= 0.7 UPTO30' Kzt= 1.0 (FIGURE 6-4, ASCE 7 -05) Gf = 0.85 (GUST FACTOR) qz = 0.00256 x Kz x Kzt x Kd x VA2 x I (EQ. 6-15) qz = 11.7 PSF Cf = 1.3 (FIG. 6 -21, ASCE 7 -05, H/D < 1.0, FOR MECHANICAL UNIT, F = qz x Gf x Cf x Af (EQ. 6-28) F = 12.88 Af UNIT LENGTH (L) = 35.4 FT UNIT WIDTH (W) = 11.7 FT UNIT HIGHT (H) = 6.80 FT SHORT DIRECTION: F wind = 4,029 Ibs LONG DIRECTION: F wind = 1,332 Ibs ProieC.Subpct BY Dine Wei No Job No /3C Jao Date and Time: 1/27/2010 3:14:51 PM MCE Ground Motion - Conterminous 48 States Zip Code - 98188 Central Latitude = 47.447736 Central Longitude = - 122.273462 Period MCE Sa (sec) ( %g) 0.2 133.7 MCE Value of Ss, Site Class B 1.0 046.0 MCE Value of S1. Site Class B Spectral Parameters for Site Class D 0.2 133.7 Sa = FaSs, Fa = 1.00 1.0 070.8 Sa = FvS 1, Fv = 1.54 0.1.,- 0 C.) 4 SEISMIC (2006 IBC) ZIP CODE: 98188 LATITUDE = 47.4477 LONGITUDE = - 122.2735 Ss = 1.337 g S1 = 0.46 g SITE CLASS "C" SDC = D Fa = 1 Fv = 1.54 Sms = Fa x Ss = 1.337 g Sm1 = Fv x S1 = 0.71 g Sds = 2/3 Sms = 0.89 g Sd1 = 2/3 Sm1 = 0.47 g Fp = (0.4 Ap.Sds.Wp /(Rp /Ip)) / (1 + 2 Z/H) Ap = 2.5 Ip= 1 Rp = 6 Sds = 0.89 (EQ. 13.3 -1) Project S.,D,;eat By Dale ) -2' )c2 St.�ei N� Job No / %_d_ f ° °� Z/H= 1 Wp = 15226 Ibs Fp = 6,786 lbs Fp (MAX) = 1.6 Sds.Ip.Wp = 21,714 Ibs > Fp O.K. Fp (MIN) = 0.3 Sds.Ip.Wp = 4,071 Ibs < Fp O.K. Fp (ASD) = Fp / 1.4 = 4,847 lbs (SEISMIC GOVERNS IN BOTH DIRECTIONS) CHECK UNIT STABILITY: SHORT DIRECTION: F(SEISM.)= 4,847 Ibs M (O.T.) = 16480 Ibs-ft M (REsis.) = 89072 Ibs-ft 0.70 M (R)= 62350 Ibs -ft > M (O.T.) NO UPLIFT USING: MINIMUM (24) -#12 SCREWS EACH SIDE OF THE UNIT / CURB F(seis.) / #12 SCREW= 84 Ibs - O.K. 0 4 Prolec:Sub;eci By 62 Sheet Nom Date Jota No APPENDIX Fort Dent Replacement Unit - MM January 14. 2010 Performance Data - Commercial Rooftop Air Conditioning Units (Large) Tags with relief Design airflow (cfm) 36000 Exhaust fan airflow (cfm) 32400 Cooling EDB (F) 80.00 Cooling EWB (F) 67.00 Ambient temp (F) 95.00 Leaving Coil DB (F) 58.44 Leaving Coil WB (F) 57.39 Leaving Unit DB (F) 61.76 Leaving Unit WB (F) 58.65 Gross total capacity (MBh) 1084.34 Gross sensible capacity (MBh) 847.39 Gross latent capacity (MBh) 236.95 Net total capacity (MBh) 965.54 Net sensible capacity (MBh) 728.58 Net sensible heat ratio ( %) 75.46 Supply duct static pressure (in H2O) 2.500 Retum duct static pressure (in H2O) 1.000 Total static pressure (in H2O) 4.899 Supply motor brake horsepower (bhp) 41.31 Supply fan RPM (rpm) 1319 Exhaust static pressure (in H2O) 1.000 Exhaust motor brake horsepower (bhp) 20.82 Exhaust fan RPM calculated (rpm) 681 System power (kW) 129.03 EER @ ARI (EER) 9.8 IPLV @ ARI (IPLV) 12.3 Minimum circuit ampacity (A) 260.90 Maximum overcurrent protection (A) 300.00 Minimum disconnect switch size (A) 289.00 Recommended dual element (A) 300.00 Compressor 1 count (Each) 4.00 Compressor 1 RLA (A) 36.00 Compressor 2 count (Each) 0.00 Compressor 2 RLA (A) 0.00 Supply fan motor FLA (A) 30.50 Supply fan count (Each) 2.00 Condenser fan FLA (A) 14.40 Exhaust fan motor FLA (A) 30.50 Other FLA (A) 2.00 Evaporator face area (sq ft) 59.30 Evaporator rows (Each) 4.00 Evaporator fin spacing (Per Foot) 148 Condenser rows (Each) 3.00 Condenser fin spacing (Per Foot) 144 Total weight (lb) 15226.0 FLO = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 4 of 14 Others Fort Dent Replacement Unit - MM Unit Dimensions - Commercial Rooftop Air Conditioning Units (Large) Item: Al Qty: 1 Tag(s): with relief 5 718" January 14, 2010 4119" DIA HOLES FOR STEAM/HOT WATER PIPE 280- 426 3/4" 257 See" 64 3/8" 11 5 7/T—I 1 1116" DIA HOLES 24v CUSTOMER CONNECT 424 3/4" /3 1/7' DIA HOLES FOR GAS PIPE 38 343" 79 315' 7358" 75/16' 1 48 3/8" 140 318' 4 1/5' DIA HOLE HIGH VOLTAGE POWER SUPPLY= 155 1/8" 180 1/8- 168 9/16- 170 9/16" 172 3/4" 174 3/4' 143 3/5' FLD = Fumished by Trane U.S. Inc. / Installed by Equipment Submittal Others Page 8 of 14 Fort Dent Replacement Unit - MM Unit Dimensions - Commercial Rooftop Air Conditioning Units (Large) Item: Al Qty: 1 Tag(s): with relief January 14, 2010 TYPICAL ROOF CURB AND BASE PAN DETAIL Ships with Curb. F*d 11slafad Gasbl, EL 1 pri7. 11 Srtn� _... w- lthrml Roof Curb — 2.13116• -- r71mnJ UM ease l-iftng Lap 4' long -- one- — p6mry rx4'Mkt 150mn a 101t1m) IFI$ hed wror Ka) _ 1- 19112- 11 Ni TYPICAL PEDESTAL AND BASE PAN DETAIL 19/]2• � — 11 1 -7nQ• rTMV (71nT FLO = Fumished by Trane U.S. Inc. / lnstalled by Equipment Submittal Others Page 10 of 14 Fort Dent Replacement Unit - MM . Weight, Clearance & Rigging Diagram - Commercial Rooftop Air Conditioning Units (Large) Item: Al Qty: 1 Tag(s): with relief RIGGING ISOMETRIC VIEW OF UNIT SERVICE CLEARANCE 72 114" x - CALCULATED WEIGHT NIA POINT LOAD 1: POINT LOAD 2. POINT LOAD 3 POINT LOAD 4: POINT LOAD 5 POINT LOAD 6 POINT LOAD T POINT LOAD 8: POINT LOAD 9: POINT LOAD 10: TOTAL WEIGHT CENTER OF GRIVRY X CENTER OF GRIVRY Y 1480.8 b 1509.0 b 14965b 1524 7 Ib 15093b 1537 5 b 1522 0 Ib 1550.2 b 15338b 1561.9 lb January 14, 2010 15226 0 b 17.58 ft 5.92n NOTES 1. THE ACTUAL WEIGHT IS STAMPED ON THE UNIT NAMEPLATE. 2. THE WEIGHT SHOWN REPRESENT THE TYPICAL UNIT OPERATING WEIGHTS FOR THE UNIT SELECTED 96` 2 4 Y 3 5 8 7 96- CENTER OF GRAVITY AND CLEARANCES PLAN VIEW OF UNIT SERVICE CLEARANCE FLO = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 12 of 14 Others • E PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -021 PROJECT NAME: FORT DENT 1 SITE ADDRESS: 6720 FORT DENT WAY X Original Plan Submittal Response to Correction Letter # DATE: 02 -12 -10 Response to Incomplete Letter # Revision # After Permit Issued DEPART,M,E, JNTS: 4uing Division IN Public Works AWL 02il )111 ire Prevention ® Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -16 -10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 03 -16 -10 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pf ter Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LB.I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Macdonald /Miller Fac Sol Inc UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite /Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State Wa Expiration Date 12/31/2010 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC Divco Incorporation Construction Contractor General Unused 12/3/2002 11/7/2010 Active MACDOMR026RU Macdonald Miller Rsdntl Inc Construction Contractor Unused General 12/31/1998 12/31/2001 Archived MACDOMR0760P Macdonald Miller Residential Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC Divco Energy Control Company Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM *248J9 Macdonald Miller Co Construction Contractor General Unused 4/29/1976 2/1/2002 Archived ENCOMMS984CA Encompass Mechanical Services Construction Contractor General Unused 2/1/2002 2/1/2004 Expired LINFOAR980QG Linford Air &Amp; Refrigertn Inc Construction Contractor General Unused 11/7/2002 11/7/2004 Inactive DIVCOI *031L4 Divco Inc Construction Contractor General Unused 6/24/1997 8/1/2003 Relicensed Business Owner Information Name Role Effective Date Expiration Date Turley, Douglas Chief Executive Officer 02/13/2008 Turley, Douglas Chief Operating Officer 02/13/2008 Sigmund, Fredric President 12/31/2002 Hack, Richard Secretary 02/13/2008 Kopet, Tyler Treasurer 12/31/2002 https://fortress.wa.gov/lni/bbip/Print.aspx 03/02/2010 0 0 N i i rn w 0 0 0 v 0 2 0 0 rn ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD - MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL ABBV OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER SYMBOL DESCRIPTION- POWERED 1 1/2 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR FSD- 10. HORIZONTAL, 3-V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 212 OR EQUAL. 1 1/2 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V FSD -2 <> ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 312 OR EQUAL. FSD -3 FSD -4 FSD -5 FSD -6 3 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 231 OR EQUAL. 3 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 311 OR EQUAL. 1 '1/2 HOUR TUNNEL CORRIDOR FIRE /SMOKE DAMPER: LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212 -1 OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK OF SD 212 OR EQUAL. SD- 1 K S > SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. SD -2 < S > SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK MD -1 M VCD -23 OR EQUAL. MD -2 MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL BLADES GREENHECK VCD -33 OR EQUAL. SCD -1 SC SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY GREENHECK SMD 202 OR EQUAL. -2 .0. SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY SCD AIRFOIL BLADE GREENHECK SMD 301 OR EQUAL. NOTES SYMBOL 1,2 I FD -1 1,2 1,2 1,2 1,2 1,2 1,2 1,2 3 4 1,2 1,2 NOTES :' 'I. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR'. 3. CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN/CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. DAMPER FAILS CLOSED FD -2 FD -3 i FD -4 FD -5 FD -4 DESCRIPTION -NON POWERED 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 150 TYPE A OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 150 TYPE B OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2 TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE LINK, GREENHECK DFD -110 OR EQUAL. CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. BDD \ BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL. BAR BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) RUSKIN CBD2. NO SUBSTITUTE ALLOWED. VOLUME DAMPER: SHOP FABRICATED, W /LOCKING QUADRANT. NOTES UNIT NO. RTU 1 PACKAGED ELEC AIR CONDITIONING SCHEDULE NOM 1 HEAT MFG & MODEL NO. TONS i KW 1 STG 99 j - RTU -1 I TRANE SXHKC904 90 SUPPLY FAN 1 EXHAUST FAN FAN 1 OA j FAN CFM 1 ESP i HP ■ ' CFM ; CFM ESP HP EER IPLV -889 ' 36 T (2) 25 ,1 9,000 9.8 12.3 ELECTRICAL WT VOLT /PH MCA 1 LBS ' NOTES 469/3 24-5 1437000 j DEMO EXISTING UNIT 460/3 261 114,9691 REPLACEMENT UNIT, 1-6 THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON- PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC: POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 12. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 13. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 14. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 15. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 16. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 17. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 18. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. TITLE PROJECT ENGINEER ACCOUNT EXECUTIVE SYSTEMS SPECIALIST ACCOUNT MANAGER SHEET METAL FOREMAN COMMISSIONING FOREMAN ELECTRICAL FOREMAN FACILITIES MANAGER NAME CHRIS LEE DAN FREYLING LINDSEY ANDREWS STEVE FLINK CHRIS HOLLINGSWORTH KURT KIRCHNER MIKE MCGIVERN KEITH CHALCRAFT COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 - 768 -4266 206 - 768 -4056 206 - 768 -4208 253 - 680 -3172 206 -407 -2620 206 -407 -2614 206 -571 -3057 FAX NUMBER 206 - 768 -4267 206 - 768 -4057 206 - 768 -4209 206 -407 -2621 206 -407 -2615 JOHN C. RADOVICH DEV CO 206 - 229 -0474 206 - 838 -1683 NAME TM0.01 TM0.01 S TM2.03 TM3.01 TITLE SCHEDULES - HVAC SITE MAP - HVAC ROOF PLAN - HVAC ELEVATIONS - HVAC NAME TITLE REPLACE ROOFTOP A/C UNIT RTU -1. RELOCATE ELECTRICAL DISCONNECT SWITCH FOR RTU -1. COMMISSION RTU -1. APN # 2954900455 LEGAL DESCRIPTION: GUNDAKERS INTERURBAN ADD POR OF VAC TRACTS 4 THRU 9 & 12 THRU 17 & VAC STS ADJ IN GUNDAKERS INTERURBAN ADD LY WITHIN SECS 23 & 24 TWP 23 N RGE 4 EWM - BEG AT HWY ENGR STA P 0 T (2M) 127 +45 ON THE 2M LN SHOWN ON ST HWY MAP ON PSH NO 1 (SR 405) GREEN RIVER INTERCHANGE SHEET 2 OF 4 SHEETS ESTB BY COMM RES NO 1192, FEBRUARY 19, 1962, TH NELY AT R/A TO SD 2M LN N 30 -27 -06 E 218.36 FT TAP ON A LN PLW & 140 FT, MEAS AT R/A, NELY OF SWLY MGN OF VAC KENNEDY ST, 67TH PLACE S, SD PT BEING TPOB TH ALG SD PLL LN N 59 -32 -54 W TO BANK OF GREEN RIVER TH ALG SD BANK THE FOLG COURSES: N 38 -19 -12 E TAP LY S 30 -04-58 W 334.53 FT FR SWLY LN OF LANDS CONVEYED TO K C UNDER RECORDING NO 7507300471 & N 30 -04 -58 E 334.53 FT TO SD SWLY LN TH ALG SD SWLY LN S 59 -24-45 E 183.62 FT TAP ON NWLY LN OF LANDS CONVEYED TO CITY OF TUKWILA RECORDING NO 7410290105TH ALG LAST SD NWLY LN THE FOLG COURSES: FROM A TANGENT BEARING S 30 -53-45 W ALG ARC OF CURVE TO LFT RAD OF 60 FT & CIA OF 33 -10 -27 ARC LENGTH 34.74 FT TH TANGENT TO THE PRECEDING CURVE S 02 -16-42 E 52.69 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 32 FT & C/A OF 24 -24-42 ARC LENGTH 13.63 FT TH TANGENT TO PRECEDING CURVE S 22 -08 -00 W 223.43 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 270 FT & C/A OF 08 -19 -06 ARC LENGTH 39.20 FT TH TANGENT TO PRECEDING CURVE S 30 -27 -06 W 66.52 FT TO TPOB LESS POR TO CITY OF TUKWILA UNDER RECORDING NO 7708040599 .TE PERMIT ►wa-..:bUiRED FOR: ❑ t�rtical EElectrichaca1 �i Pkimbing - as Piping ,r of Tukwila DWG DIVISION, W Cti 0 0 U c 0 a) 0 rn 0 M co m o N 4) 0 ti 0 E 0 U iv E U E WA Lic No: MACDOFS980RU I I I 1 1 1 1 01 cV O I- LL! 0 0 w 0- 1 1 1 1 1 1 Ia w 0 REVISIONS: w 0 REVISIONS: FILE Copy Penult No. NOTES: 1. R410A REFRIGERANT. 2. FACTORY CONFIGURATION: - 0- 100% ECONOMIZER W/ DRY BULB ECONOMIZER CONTRI -'HIGH EFFICIENCY SUPPLY AND'EXHAUST MOTORS -;VAV SUPPLY AIR TEMPERATURE CONTROL WITH VFD - 'LONTALK COMMUNICATION INTERFACE MODULE - HOT GAS BYPASS - EXTENDED GREASE LINES - ACCESS DOORSb 1, k� - RETURN AIR SMOKE DETECTOR. - 'CONDENSER BASE PAN 3. M -M TO UPGRADE ELECTRICAL PANELS AND CONDUCTORS AS NECESSARY TO MEET ELECTRICAL MCA. 4. M M TO RELOCATE ROOFTOP DISCONNECT SWITCH TO PROVIDE NECESSARY ELECTRICAL CLEARANCES. 5. M -M TO PROVIDE AND INSTALL RETURN AIR SMOKE DETECTOR. COMMUNICATION FROM SMOKE DETECTOR TO BUILDING FIRE CONTROL PANEL BY OTHERS. 6. STRUCTURAL CALCULATION PERFORMED AT'A HIGHER WEIGHT (15,226 LBS); TO ACCOMMODATE WEIGHT OF FUTURE POWERED EXHAUST.; JOB SITE Plan review app • Is subject to Approval of co the • - I'on of any a of approved Copy and i and does not F:f; 'iii{ {, Receipt w( -f {lied ° • Ln S 154th St S 153r St Tukwila Park �CG a\ 0 405 VICI NO SC u BY Date: _E REVISIONS No changes shall be made to the scope of uvork without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. (o -oz City Of Tukwila BUILDING D ION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2010 City of Tukwila BUILDING DIVISION RECEIVED FEB 12 2010 PERMIT CENTER W Z 00 Z Q M,. oW,, 0 D Q J LL � I- ® o (cifii ENGINEER: C LEE CHECKED BY: B GEZON z 0 U I..L (1) z 0 0 0 L.L. 0 w U) LAST REVISED: 02 -11 -10 DATE PLOTTED: 02 -11 -10 CAD: ISSUE DATE: R VILLANUEVA 02-11-1 0 DRAWING NUMBER: D- 0662 - 7699649 -00 SHEET NUMBER: TM0.01 fi EG ,ND DESCRIPTION SYMBOL ';DESCRIPTION SYMBOL BARE SHEETMETAL 14/12 1 ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") 120W SOUNDLINE SHEETMETAL (1" LINING) E I 14/12SL 1CLEANROOM QUALITY DUCTWORK ! 14/12C ! I SHEETMETAL WRAPPED W/ INSULATION (2 ") ! 14/12W ;BARE FLAT OVAL SHEETMETAL { 14/120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 14/120W EXPOSED QUALITY SHEETMETAL 14/12Q ' DUCTBOARD (1" FIBERGLASS) j 14/1 2DB ;r EXAMPLE OF NEW 14/12 EXAMPLE OF NOT IN CONTRACT (NIC) 14/12 EXAMPLE OF DEMO r � / 1 FLEX DUCT I EXAMPLE OF EXISTING 1 \( () ( 14/12 FLEX CONNECTOR UNIT NO. RTU 1 PACKAGED ELEC AIR CONDITIONING SCHEDULE NOM 1 HEAT MFG & MODEL NO. TONS i KW 1 STG 99 j - RTU -1 I TRANE SXHKC904 90 SUPPLY FAN 1 EXHAUST FAN FAN 1 OA j FAN CFM 1 ESP i HP ■ ' CFM ; CFM ESP HP EER IPLV -889 ' 36 T (2) 25 ,1 9,000 9.8 12.3 ELECTRICAL WT VOLT /PH MCA 1 LBS ' NOTES 469/3 24-5 1437000 j DEMO EXISTING UNIT 460/3 261 114,9691 REPLACEMENT UNIT, 1-6 THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON- PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC: POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 12. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 13. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 14. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 15. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 16. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 17. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 18. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. TITLE PROJECT ENGINEER ACCOUNT EXECUTIVE SYSTEMS SPECIALIST ACCOUNT MANAGER SHEET METAL FOREMAN COMMISSIONING FOREMAN ELECTRICAL FOREMAN FACILITIES MANAGER NAME CHRIS LEE DAN FREYLING LINDSEY ANDREWS STEVE FLINK CHRIS HOLLINGSWORTH KURT KIRCHNER MIKE MCGIVERN KEITH CHALCRAFT COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 - 768 -4266 206 - 768 -4056 206 - 768 -4208 253 - 680 -3172 206 -407 -2620 206 -407 -2614 206 -571 -3057 FAX NUMBER 206 - 768 -4267 206 - 768 -4057 206 - 768 -4209 206 -407 -2621 206 -407 -2615 JOHN C. RADOVICH DEV CO 206 - 229 -0474 206 - 838 -1683 NAME TM0.01 TM0.01 S TM2.03 TM3.01 TITLE SCHEDULES - HVAC SITE MAP - HVAC ROOF PLAN - HVAC ELEVATIONS - HVAC NAME TITLE REPLACE ROOFTOP A/C UNIT RTU -1. RELOCATE ELECTRICAL DISCONNECT SWITCH FOR RTU -1. COMMISSION RTU -1. APN # 2954900455 LEGAL DESCRIPTION: GUNDAKERS INTERURBAN ADD POR OF VAC TRACTS 4 THRU 9 & 12 THRU 17 & VAC STS ADJ IN GUNDAKERS INTERURBAN ADD LY WITHIN SECS 23 & 24 TWP 23 N RGE 4 EWM - BEG AT HWY ENGR STA P 0 T (2M) 127 +45 ON THE 2M LN SHOWN ON ST HWY MAP ON PSH NO 1 (SR 405) GREEN RIVER INTERCHANGE SHEET 2 OF 4 SHEETS ESTB BY COMM RES NO 1192, FEBRUARY 19, 1962, TH NELY AT R/A TO SD 2M LN N 30 -27 -06 E 218.36 FT TAP ON A LN PLW & 140 FT, MEAS AT R/A, NELY OF SWLY MGN OF VAC KENNEDY ST, 67TH PLACE S, SD PT BEING TPOB TH ALG SD PLL LN N 59 -32 -54 W TO BANK OF GREEN RIVER TH ALG SD BANK THE FOLG COURSES: N 38 -19 -12 E TAP LY S 30 -04-58 W 334.53 FT FR SWLY LN OF LANDS CONVEYED TO K C UNDER RECORDING NO 7507300471 & N 30 -04 -58 E 334.53 FT TO SD SWLY LN TH ALG SD SWLY LN S 59 -24-45 E 183.62 FT TAP ON NWLY LN OF LANDS CONVEYED TO CITY OF TUKWILA RECORDING NO 7410290105TH ALG LAST SD NWLY LN THE FOLG COURSES: FROM A TANGENT BEARING S 30 -53-45 W ALG ARC OF CURVE TO LFT RAD OF 60 FT & CIA OF 33 -10 -27 ARC LENGTH 34.74 FT TH TANGENT TO THE PRECEDING CURVE S 02 -16-42 E 52.69 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 32 FT & C/A OF 24 -24-42 ARC LENGTH 13.63 FT TH TANGENT TO PRECEDING CURVE S 22 -08 -00 W 223.43 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 270 FT & C/A OF 08 -19 -06 ARC LENGTH 39.20 FT TH TANGENT TO PRECEDING CURVE S 30 -27 -06 W 66.52 FT TO TPOB LESS POR TO CITY OF TUKWILA UNDER RECORDING NO 7708040599 .TE PERMIT ►wa-..:bUiRED FOR: ❑ t�rtical EElectrichaca1 �i Pkimbing - as Piping ,r of Tukwila DWG DIVISION, W Cti 0 0 U c 0 a) 0 rn 0 M co m o N 4) 0 ti 0 E 0 U iv E U E WA Lic No: MACDOFS980RU I I I 1 1 1 1 01 cV O I- LL! 0 0 w 0- 1 1 1 1 1 1 Ia w 0 REVISIONS: w 0 REVISIONS: FILE Copy Penult No. NOTES: 1. R410A REFRIGERANT. 2. FACTORY CONFIGURATION: - 0- 100% ECONOMIZER W/ DRY BULB ECONOMIZER CONTRI -'HIGH EFFICIENCY SUPPLY AND'EXHAUST MOTORS -;VAV SUPPLY AIR TEMPERATURE CONTROL WITH VFD - 'LONTALK COMMUNICATION INTERFACE MODULE - HOT GAS BYPASS - EXTENDED GREASE LINES - ACCESS DOORSb 1, k� - RETURN AIR SMOKE DETECTOR. - 'CONDENSER BASE PAN 3. M -M TO UPGRADE ELECTRICAL PANELS AND CONDUCTORS AS NECESSARY TO MEET ELECTRICAL MCA. 4. M M TO RELOCATE ROOFTOP DISCONNECT SWITCH TO PROVIDE NECESSARY ELECTRICAL CLEARANCES. 5. M -M TO PROVIDE AND INSTALL RETURN AIR SMOKE DETECTOR. COMMUNICATION FROM SMOKE DETECTOR TO BUILDING FIRE CONTROL PANEL BY OTHERS. 6. STRUCTURAL CALCULATION PERFORMED AT'A HIGHER WEIGHT (15,226 LBS); TO ACCOMMODATE WEIGHT OF FUTURE POWERED EXHAUST.; JOB SITE Plan review app • Is subject to Approval of co the • - I'on of any a of approved Copy and i and does not F:f; 'iii{ {, Receipt w( -f {lied ° • Ln S 154th St S 153r St Tukwila Park �CG a\ 0 405 VICI NO SC u BY Date: _E REVISIONS No changes shall be made to the scope of uvork without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. (o -oz City Of Tukwila BUILDING D ION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 5 2010 City of Tukwila BUILDING DIVISION RECEIVED FEB 12 2010 PERMIT CENTER W Z 00 Z Q M,. oW,, 0 D Q J LL � I- ® o (cifii ENGINEER: C LEE CHECKED BY: B GEZON z 0 U I..L (1) z 0 0 0 L.L. 0 w U) LAST REVISED: 02 -11 -10 DATE PLOTTED: 02 -11 -10 CAD: ISSUE DATE: R VILLANUEVA 02-11-1 0 DRAWING NUMBER: D- 0662 - 7699649 -00 SHEET NUMBER: TM0.01 -r-- O 0) co rn S o+ c W O 0 U 'D O H 0 0 0 0 co co t, to 1:33:18 PM O 0 N z 0 7 MacDonald - Miller CD CO h T CO CD 1.7 co w E o mmo U) u_ • U) 0 O N cs, E • Q O O CO .- O iy N 0�; ti C O tiCL WA Lic No: MACDOFS980RU ZO \E: RCV IEXPIRES 17.13i / 10 uJ 0 REVISIONS: °I LLI 0 1 CV 0 0 0 O_ a_ 1 1 1 1 1 la REVISIONS: ZO \E: RCN' SOUND LEVEL 6720 FORT DENT WAY UNIT : RTU -1 SOUND POWER LEVELS PER ARI 370 DATA PROVIDE BY MANUFACTURER = 101 dBA DISTANCE BETWEEN EQUIPMENT AND NEAREST RECEIVER = 317' ESTIMATED SOUND LEVEL AT RECEIVER = 54 dBA (NOTE 1) ZONING OF RECEIVING AREA = RCM (EDNA CLASS B COMMERCIAL) ZONING OF PROPERTY = RCM (EDNA CLASS B COMMERCIAL) ALLOWED NOISE LEVEL FOR NIGHT TIME CLASS B TO CLASS B ZONING = 60 dBA NOISE AT RECEIVER IS BELOW LEVELS ALLOWED BY 173-60 WAC. NOTE 1: A 7 -FOOT TALL SCREEN WALL SURROUNDS RTU -1. STRAIGHT LINE DISTANCES ARE TAKEN FROM EQUIPMENT TO RECEIVING AREA WITHOUT ACCOUNTING FOR THE SCREEN WALL (MOST CONSERVATIVE APPROACH). REVIEWED FOR CODE COMPLIANC E APPROVED 11 o FEB 2 5 2010 City of Tukwila BUIlFige V !}N FEB 12 2010 P. IT C CD W W z OO 7� L co Owz D I- 1- D Ca 5- I—/0 r E-1N ,- ENGINEER: C LEE CHECKED BY: B GEZON CAD: z 0 ce 0 z 0 ce 0 0 0 W (1) V, LAST REVISED: 02 -11 -10 DATE PLOTTED: 02 -11 -10 ISSUE DATE: R VILLANUEVA 02 -11 -10 DRAWING NUMBER: D- 0662 - 7699649 -00 . SHEET NUMBER: TM0.01 S a N N 0 0 N m CO EXHAUST FAN REPLACE RTU -1, INSTALL NEW UNIT ON EXISTING ROOF CURB, NO ADAPTER REQUIRED. SEE STRUCTURAL DRAWINGS FOR UNIT LOCATION. PROVIDE STRUCTURAL SUPPORT AS INDICATED ON THE STRUCTURAL CALCULATIONS. RELOCATE ELECTRICAL DISCONNECT PANEL TO COMPLY WITH NEC CLEARANCES, SHOW NEW LOCATION ON AS —BUILD DRAWINGS RTU -1 EXISTING SCREENING, 7' —O" HEIGHT MEASURED FROM ROOF DECK EXISTING 56 "x56" BAROMETRIC RELIEF DAMPERS AND DUCT EXISTING 86x52 ROOF CURB E 0 U a) E U a E WA Lic No: MACDOFS980RU 1 1 1 1 1 1 1 1 w 0 REVISIONS: EXPIRES /Z./31/ 10 cV 0 v7 0 0 O_' W a_ 1 1 1 1 1 1 1a REVIEWED FOR CODE COMPLIANCE APPROVED FEB 25 2010 City ofTukwila BUILDN@8Ei FEB 12 2010 PERMITC %I} W W Z O § >"" 1Z owZrn 0_Ow< Duo I- ONE ENGINEER: C LEE CHECKED BY: B GEZON REVISIONS: LAST REVISED: z 0 U LL. z 0 U 0 cn0 W 0 02 -11 -10 DATE PLOTTED: 02 -11 -10 CAD: ISSUE DATE: R VILLANUEVA 02-11-10 DRAWING NUMBER: D- 0662 - 7699649 -00 SHEET NUMBER: TM2.03 V / i / V . EXISTING SCREENING, 7' —O" HEIGHT MEASURED FROM ROOF DECK EXISTING 56 "x56" BAROMETRIC RELIEF DAMPERS AND DUCT EXISTING 86x52 ROOF CURB E 0 U a) E U a E WA Lic No: MACDOFS980RU 1 1 1 1 1 1 1 1 w 0 REVISIONS: EXPIRES /Z./31/ 10 cV 0 v7 0 0 O_' W a_ 1 1 1 1 1 1 1a REVIEWED FOR CODE COMPLIANCE APPROVED FEB 25 2010 City ofTukwila BUILDN@8Ei FEB 12 2010 PERMITC %I} W W Z O § >"" 1Z owZrn 0_Ow< Duo I- ONE ENGINEER: C LEE CHECKED BY: B GEZON REVISIONS: LAST REVISED: z 0 U LL. z 0 U 0 cn0 W 0 02 -11 -10 DATE PLOTTED: 02 -11 -10 CAD: ISSUE DATE: R VILLANUEVA 02-11-10 DRAWING NUMBER: D- 0662 - 7699649 -00 SHEET NUMBER: TM2.03 a) c0 r-- 1— c c 0 0 0 0 0 cr, GRADE SCREENING Co SCREENING RTU-1 L / ROOF r_ SOUTH BUILDING ELEVATION SCALE: 1/8" = 1'-0" - ROOF— \ 1_ \F--- 0 1 -co cv I [ [ = o , ; , , 1 RTU-1 [ EAST BUILDING ELEVATION SCALE: 1/8" = r-0" GRADE REVIEWED FOR CODE COMPLIANCE APPROVED FEB 25 2010 City of Tukwila BUILDING DIVISInN RECEIVED FEB 12 2010 PERMIT CENTER CD • ES 0 co 0 co cc cp co 0) u_ 0 0 2 0 z 0 *;C, 11111111 11111111 0" 0 0 a_ 1 1 1 1 1 Z 0 gZ co LL D ENGINEER: C LEE CHECKED BY: B GEZON L.L.1 0 REVISIONS: uJ `0( REVISIONS: .7177-7 z 0 F- 0 1— (1) 0 0 oe A 0 0 LIJ (/) (i) LAST REVISED: 02-11-10 DATE PLOTTED: 02-11-10 CAD: ISSUE DATE: R VI LLAN U EVA 02-11-10 DRAWING NUMBER: D-0662-7699649-00 SHEET NUMBER: TM3.01