HomeMy WebLinkAboutPermit M10-022 - SEGALE OFFICE BUILDINGSEGALE OFFICE BUILDING 18100 ANDOVER PK W M10 -022 City Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 3523049121 Address: 18100 ANDOVER PK W TUKW Project Name: SEGALE OFFICE BUILDING Permit Number: M10 -022 Issue Date: 05/26/2010 Permit Expires On: 11/22/2010 Owner: Name: LA PIANTA LLC Address: PO BOX 88028 , TUKVVILA WA 98138 Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor STEVE NELSON Phone: 206 - 575 -2000 PO BOX 88028 , TUKWILA WA 98138 SEGALE PROPERTIES LLC PO BOX 88028 , TUKWILA WA 98138 License No: SEGALPL902CQ Phone: 206 - 575 -2000 Expiration Date: 04/01/2012 DESCRIPTION OF WORK: ROOFTOP VAV HVAC UNITS FOR FUTURE OFFICE SPACE WITH TRUNK LINE DUCT IN CORE ONLY - DUCT SYSTEM AND CONTROLS TO BE COMPLETED UNDER TENANT IMPROVEMENT. ROOFTOP HVAC FOR UNIT FOR CORE RESTROOMS AND LOBBY AREA. EXHAUST FOR CORE RESTROOMS. VENTILATION COOLING FOR ELECTRICAL AND ELEVATOR MACHINE ROOMS. Value of Mechanical: 145,000.00 Type of Fire Protection: Permit Center Authorized Signature I hereby certify that I have read an governing this work will be compli Fees Collected: $1,766.31 International Mechanical Code Edition: 2009 Date: ex ed this permit and know the same to be true and correct. All provisions of law and ordinances d wit whether specified herein or not. The granting of this permit does not p -s e to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this mechanical permit. construction or the performance of work. Signature: Print Name: vvl P CU 14.(A".l Ca CX Date: C/2- 6 Ad This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -022 Printed: 05 -26 -2010 • City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http. //www.ci.tukwila.wa.us Parcel No.: 3523049121 Address: Suite No: Tenant: 18100 ANDOVER PK W TUKW SEGALE OFFICE BUILDING PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10 -022 ISSUED 02/16/2010 05/26/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M10 -022 Printed: 05 -26 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -022 Printed: 05 -26 -2010 • A City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 'Ai /ORAL t CO c f Date: Sl2 6 /( C7 ordinances governing or local laws regulating doc: Cond -10/06 M10 -022 Printed: 05 -26 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htu,://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit N to - c)41-1 Iva. fD ig-7 Plumbing/Gas Permit Public Works Permit No. Project No. (For office us e only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 18100 Andover Park West Tenant Name: Property Owners Name: Segale Properties King Co Assessor's Tax No.: 3 S2 3 0 4- 9121 Suite Number: Floor: New Tenant: ❑ Yes Mailing Address: PO Box 88028 Tukwila City WA State ❑..No 98138 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Steve Nelson Mailing Address: PO Box 88028 Day Telephone: (206) 575 -2000 Tukwila WA 98138 E -Mail Address: snelson @segaleproperties.com City State Fax Number: (206) 575 -1837 Zip GENERAL CONTRACTOR INFORMATION — (Contractor information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Segale Properties Mailing Address: PO Box 88028 Contact Person: Steve Nelson Tukwila WA 98138 E -Mail Address: snelson @segaleproperties.com Contractor Registration Number: City State Day Telephone: (206) 575 -2000 Fax Number: (206) 575 -1837 Zip Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Lance Mueller and Associates Mailing Address: 130 Lakeside Suite 250 Contact Person: Bob Fadden E -Mail Address: bfadden @Imueller.com Seattle WA 98122 City State Zip Day Telephone: (206) 325 -2553 Fax Number: (206) 325 2553 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Engineers Northwest Mailing Address: 6869 Woodlawn Ave. NE Contact Person: Mark Nazarenus Seattle WA 98115 E -Mail Address: markn @enwseattle.com H:'Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh City State Day Telephone: (206) 525 -7560 Fax Number: (206) 973 -5601 Zip Page l of 6 MECHANICAL PERMIT INFORMATION 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Not Available at this time Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ '1'fs OOD Scope of Work (please provide detailed information): Rooftop V \V HVAC units for future office space with trunk line dude in core only - duct system and controls to be completed under tenant improvement. Roof top HVAC for unit for core restrooms and lobby area. Exhaust for core restrooms. Ventilation cooling for electrical and elevator machine rooms Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric ❑ Gas ....121 Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty , Unit Type: Qty Unit Type: Qty , Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM 2 Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU 2 Evaporator Cooler Diffuser 28 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 3 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 3 Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind H:\Applications\Fonns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 4 of 6 PERMJT APPLICATION NOTES — Applicable to all permits in this application Value of Construction In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINCR V2.5. AUT RIZED A Signature: Print Name: Bob Fadden % Lance Mueller and Associates Mailing Address: 130 Lakeside Suite 250 Date: 02/16/2010 Day Telephone: (206) 325 -2553 Seattle WA 98122 City State Zip Date Application Accepted: Date Application Expires: 1 ^ l _\ U Staff Initials: H:1Applications\Pomts- Applications. On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3523049121 Address: 18100 ANDOVER PK W TUKW Suite No: Applicant: SEGALE OFFICE BUILDING RECEIPT Permit Number: M10 -022 Status: APPROVED Applied Date: 02/16/2010 Issue Date: Receipt No.: R10 -00931 Payment Amount: $1,413.05 Initials: JEM Payment Date: 05/26/2010 09:48 AM User ID: 1165 Balance: $0.00 Payee: SEGALE PROPERTIES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 61780 1,413.05 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 1,413.05 Total: $1,413.05 PAYMENT RECEIVED doc: Receiot -06 Printed: 05 -26 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT ParcelNo.: 3523049121 Permit Number: M10 -022 Address: 18200 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 02/16/2010 Applicant: SEGALE 2 STORY OFFICE BLDG Issue Date: Receipt No.: R10 -00270 Payment Amount: $353.26 Initials: WER Payment Date: 02/16/2010 02:32 PM User ID: 1655 Balance: $1,413.05 Payee: SEGALE PROPERTIES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1273 353.26 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 353.26 Total: $353.26 doc: Receiot -06 Printed: 02 -16 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project: Type of Inspection: Address: ./6/0e) AP Date Called: Special Instructions: Date Wanted: 1/- /3-- // I f' rrn L --H'm� Requester: Phone No: caldl —S5/— 42g S 15kproved per applicable codes. Corrections required prior to approval. COMMENTS: pector: INSPECTION FEE REQU ED. Prior tolfiext inspection, fee must be at 6300 Southcenter vd.. Suite 10 . Call to schedule reinspection. •r• • ., -• - v ii•• L ".'..x : i.1$Y.a+ Vet. • ..: INSPECTION RECORD Retain a copy with permit Mw-U2? IN ' - ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451, Project: Se0.6ALe__ 6FFiee Type of Inspection: Sm0K€., .Ire-C73R Address: h? ',//.f ...,4A•in./ 4/4 Da a Called: 7p$ r--- Special Instructions: % --/1/7 Q4/ a26 -a /,206 Date Wanted: 2 3 0- // p.m. Requester: Phone No: 35.6 - /7`v'`' Approved per applicable codes. Corrections required prior to approval. CO1AMENTS: , f s r ..Si, V/ +tea — 4,,,t' /e0 :1) 67A. % L.5-2 /rt /' / _ 4/7,0"1�1% 3) h? ',//.f ...,4A•in./ 4/4 1 spector: ECTION FEE REQUIJ ED. P��r to next inspection. fee must be 6300 Southcenter 131 d.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit -W O - O2Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ^^ tV ....1 eta` Type of Inspection: kdvLs b• — 'N+.) n�� Nty Address: i 75.144 4.-aotosif i Piz Date Called: Special Instructions: Date Wante : 11i IC( lit, a.m. pnr Requester: Phone No: Approved per applicable codes. • • a Corrections required prior to approval. g COMMENTS: 'Date: NSPECTION FEE REQ RED. Prior t n " ex spection. fee must be at 6300 Southcenter Bll.. Suite 1p Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION V` 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /11/6-422 Project: _.Se. G 44 ( © 1/l e Type of Inspection: /i) es)/$' h- /Ail Address: /8/e"0 //a/OeW PA' Date Called: eti Special Instructions: Date Wanted: //-14.—/I) a,rfi (p..,.nJ' ,. Requester: • Phone No: b?_c 6 -.15'4 "- /iq/q El-Approved per applicable codes. • Corrections required prior to approval. COMMENTS A £ g TO 7AISY/L P&P l 4 v PECTION FEE REQUIRE Prior next inspection. fee must be at 6300 Southcenter Blvd.. uite 0. Call to schedule reinspection. •a. : y.... •• : w •• • s e • 1,74,. • : 1 5 S v . •74.t •4 10 -01 -2010 Tu h -. Jim Haggerton, Mayor Department of Community Development Jack Pace, Director STEVE NELSON PO BOX 88028 TUKWILA WA 98138 RE: Permit No. M10 -022 18100 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/22/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 11/22/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M10 -022 ') 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 • • Pk i PLAN REVIEW '0 NG SLIP ACTIVITY NUMBER: M10 -022 DATE: 02 -16 -10 PROJECT NAME: SEGALE 2 STORY OFFICE BLDG SITE ADDRESS: 18100 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: AC 'guiIding Division )115*-W Public Works ❑ W°1' to Fire e Prevention Structural Planning Division Permit Coordinator r DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -23 -10 Complete Incomplete n Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route gj, Structural Review Required REVIEWER'S INITIALS: DATE: No further Review Required APPROVALS OR CORRECTIONS: DUE DATE: 03-23-10 Approved Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople liter Friendly Page 0 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Segale Properities Llc UBI No. 602023533 Phone 2065752000 Status Active Address Po Box 88028 License No. SEGALPL902CQ Suite /Apt. License Type Construction Contractor City Tukwila Effective Date 2/18/2010 State Wa Expiration Date 4/1/2012 Zip 981382028 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LAPIALP055MZ La Pianta Limited Partnership Construction Contractor General Unused 7/9/1995 4/1/2001 Archived SEGALBP151M5SegaleBusiness Park Construction Contractor General Unused 7/25/1985 7/9/1995 Archived LAPIAL'008J8 La Pianta Llc Construction Contractor General Unused 4/28/2000 4/1/2010 Inactive Business Owner Information Name Role Effective Date Expiration Date Segale, Mario A Agent 02/18/2010 Amount Segale, Mario A Partner /Member 02/18/2010 10DLS31006 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 SAFECO INS CO OF AM 6115146 02/18/2010 Until Cancelled $12,000.00 03/28/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 ALASKA NATIONAL INSURANCE COMP 10DLS31006 04/01/2010 04/01/2011 $1,000,000.00 03/31/2010 1 ALASKA NATIONAL INSURANCE COMP 09DLS31006 02/18/2010 04/01/2010 $1,000,000.0003 /31/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: / /fortress.wa. gov /lni/bbip /Print. aspx 05/26/2010 C: \Documents and Settings \Natalie Thrower \My Documents \Projects \00101 Segale Two Story\00101M1.0.dwg, 2/5/2010 3:36:08 PM, NMT ROOFTOP GAS ELECTRIC EQUIPMENT SCHEDULE TAG NOM. TONS RTU TYPE SUPPLY FAN PERFORMANCE TC (a) {MBH) SC (b) (MBH) EAT (DEG F) EER HTG INPUT (MBH) HTG OUTPUT (MBH) AFUE ( %) MIN OSA CFM EXHAUST FAN PERFORMANCE ELECTRICAL DATA WEIGHT (d3 (LBS) SOUND RATING (DBA) BRAND MODEL NOTES CFM ESP (IN_ WG) HP CFM ESP (IN. WG) HP V/PHMZ FLA MC A CIRCUIT AMPS (c) AC -1 60 VERT 18,000 3.0 40 700 603 80/63 10.3 500 410 82 -- 18,000 0.75 7.5 460/3/60 -- -- - 12,000 -- TRANE SFHLF604 1 AC -2 60 VERT 18,000 3.0 40 700 603 80/63 10.3 500 410 82 -- 18,000 0.75 7.5 460/3/60 -- -- - 12,000 -- TRANE SFHLF604 1 AC -3 7.5 VERT 3,000 0.75 89 80 80/63 11.2 150 120 80 1300 - -- -- 460/3/60 17.8 22 25 1,200 87 TRANE YSC092E4RY 2 Footnotes - (a) Total cooling. (b) Sensible cooling. (c) Circuit breaker or MOCP amps. (d) Includes roof curb. Notes: 1. Variable volume with high capacity cooling, modulating low gas heat and 2" pleated, ASHRAE 30% filters. Factory dry bulb economizer and 100% power exhaust. Supply/Exhaust Fans: Include VFD, high effiency motors and 2" internal spring isolation. Include 0 -10 volt Generic BAS control module - refer to Controls section for control system details. Include factory roof curb. 2. Constant volume with dual compressors and medium gas heat with stainless steel heat exchanger. Factory dry bulb economizer with field installed power exhaust (100%). Include 2" pleated, MERV 13 filters and spring isolated roof curb. FAN SCHEDULE TAG TYPE DRIVE CFM ESP (IN. WG) HP (a) ELECTRICAL DATA WEIGHT �`} (LBS) SOUND RATING (BONES) BRAND MODEL NOTES V /PH/HZ FLA CIRCUIT AMPS (b) EF -1 ROOF EXHAUST BELT 1300 12" 1/3 230/3/60 2 15 130 9.0 ACME PV135F 1 EF -2 ROOF EXHAUST BELT 1800 3/8" 12 230/3/60 3 15 160 9.7 ACME PV150G 1 EF -3 ROOF EXHAUST DIRECT 600 12" 1/4 230/1/60 4 15 100 7.0 ACME PRN126E 1, 2 Footnotes - (a) HP or Watts (b) Circuit breaker or MOCP amps. (c) Weight includes roof curb. Notes: 1. Include BDD, factory disconnect and factory roof curb. 2. Include speed controller. TAG - EQUIPMENT SCHEDULE DS -1 DUCT SILENCER, (verify count) Low frequency, air pressure drop = 0.15" SP @ 750 fpm face velocity. Insertion loss (dB) by frequency: 63 Hz = 5, 125 Hz = 9, 250 Hz = 15, 500 Hz = 23. 36" long, see plan for sizes and count. Standard galvanized steel construction & Std. fill. Dynasonics LF79. TAG CONTROLS DDC CONTROL SYSTEM, Standard factory DDC control system, Trane. Verify system details prior to purchase. T1 LINE VOLTAGE THERMOSTAT, heating /cooling, 0 -100 degrees F range, 120v or 240v. Dayton 2E816 or approved equal. M1 MOTORIZED DAMPER, two position, spring return actuator with damper. Actuator: Belimo LF120 (120 volt) or LF24 (24 volt). Damper: Ruskin CD -36 or CDRS25. BD BACKDRAFT DAMPER, Barometric, counterbalance type with field adjustable feature. Ruskin #CBD -2 SD SMOKE DETECTOR, Systems Sensor DH100AC series, Firex 2650 series or approved equal to meet local & state code. Provide a smoke detector in the return duct of all air moving systems (or where multiple air handling systems) supplying air in excess of 2,000 cfm to an enclosed spaces within buildings. Wire to shutoff units when smoke is detected. Connect to trouble zone on fire alarm system. UL 268A approved. Per 2006 IMC, sec. 606. CONTROL NOTE: System capable of minimum 5 degree deadband, seven day programmable for each day per week, outside air dampers close automatically when system is off or upon power failure, interlocked to prevent simultaneous heating and cooling. Mount thermostat or sensor 60 inches above floor. CONTROL SEQUENCE ECONOMIZERS Automatic modulation of outside air and return air dampers to provide up to 100% of outside air to reduce or eliminate the need for mechanical cooling as determined by the condition of outside air for cooling duty. System shall be able to integrate the operation of outside air cooling and mechanical cooling together to provide the most economical operation to maintain indoor conditions and meet the cooling load. ELECTRICAL ROOM COOLING Individual thermostat in each electrical room, wired in parallel, controls single exhaust fan (EF -2) to provide ventilation cooling using makeup air from ceiling return air void. On call for cooling from any thermostat, exhaust fan is on. When ALL thermostats are satisfied, exhaust fan is off. ELEVATOR MACHINE ROOM COOLING Exhaust fan (EF -3) provides ventilation cooling using makeup air from ceiling return air void. On call for cooling from thermostat (T1), exhaust fan is on and motorized damper is open. When thermostat is satisfied, exhaust fan is off and motorized damper is closed. TAG GRILLE AND LOUVER SCHEDULE SUPPLY: A Square Ceiling Diffuser, Modular core, Surface frame type 1, with OBD, Titus MCD. B Not Used. RETURN/EXHAUST: C Standard fixed blade, WITH OBD, Titus 350RL_ D Standard fixed blade, NO OBD, Titus 350RL. E Standard fixed blade, Extruded Aluminum, Titus 350FL. ROOF CAPS AND WALL VENTS: F Not Used. LOUVERS: G Not Used. GENERAL GRILLE NOTES: 1. All steel construction except as noted. 2. Standard white finish except as noted. SEPARATE PERMIT REQUIRED FOR: ❑ echanical ELpectrical Er Plumbing las Piping City of Tukwila EUIf_MNG DIVISION HVAC GENERAL NOTES 1. VERIFY site conditions. 2. THERMOSTAT LOCATIONS: Verify all wall mounted control locations with 3. CODES: Comply with all local & state governing codes. 4. COORDINATE ductwork and grille locations with lighting and other related trades with architect approval. Verify clearances & ceiling elevations before installation. 5. DRAWINGS are schematic in some areas and may not show exact routing or every offset which may be required. Provide a complete & properly working system with all necessary items 6. SEISMIC BRACING: Provide to meet local code requirements. Refer to the ASHRAE standards "Practical Guide to Seismic Restraint ", 1999. 7. EXHAUST FAN TERMINATION: Shall not be less than 3 feet from a property line or openings into a building, e.g., operable windows and doors. 2006 IMC, sec. 501.2.1, item #3. 8. CONDENSATE DRAINS: Run 3/4" PVC pipe from cooling coil to nearby open site drain or to outside planting bed on ground. Elevate coil to allow for proper gravity drain operation. Provide approved "P" trap at coil outlet. 2006 IMC, sec. 307. 9. SUBMITTALS: Provide equipment submittals (before ordering & installation) on all major equipment items, controls, grilles, and louvers. Submit 4 copies to arch itect in a single notebook with items tagged according to drawing call outs. 10. TEST, ADJUST, & BALANCE: Provide proper system testing, adjusting, and balancing on both air and water according to NEBB & ASHRAE standards, including written reports. Use only technicians qualified & trained in TAB work. Includes System Commissioning: Functional testing of sequences of operation to ensure they operate in accordance with the mechanical plans (2006 WSEC, Sec 1416). Work by NEBB certified firm. 11. OPERATION & MAINTENANCE BOOKLET: Provide 0 & M manual to owner_ Include cut sheets on main equipment and controls, maintenance instructions, and marked up as built drawing (record drawings per 2006 WSEC, Sec 1416.2.4). 12. WALK -THRU instruction: Provide on site walk -thru for customer to demonstrate operation of system and answer questions. 13. GUARANTEE: Contractor shall warrant the completed system from defects for one year from date of final start up. 14. ELECTRICAL: All equipment to have a positive means of disconnect adjacent to and in sight from equipment served. Provide a 120 volt receptacle located within 25 feet of equipment for service & maintenance purposes (2006 IMC sec. 306). Line voltage work by others. 15. TEMPORARY CONSTRUCTION HEATING: DO NOT USE new warm air heating equipment and duct system to dry out building during construction. Use portable heaters. 16. ROOFTOP UNITS ON CURBS: SEAL holes and cracks between duct and roof deck inside factory roof curb for noise control. 17. ACCESS DOORS: General contractor shall install necessary access doors and /or panels as required for fire damper access for resetting. 2006 IMC sec. 607.4. DUCT NOTES 1. DUCT CONSTRUCTION and installation per latest SMACNA Standards and the 2006 IMC as required by the local code. Provide metal duct, except as noted. Underground duct shall be "Spunstrand" factory insulated fiberglass construction. 2. BALANCING DAMPERS: Provide on all supply grille run out ducts up stream of grille. 3. DUCT INSULATION: Manville fiberglass duct wrap, type 75, FSK aluminum foil facing or equal. Supply and return ducts: Within conditioned space = R -3.3; outside bldg insulation envelope (attic) = R -7; in ground, in concrete = R -5.3; exposed in same cond. space served = none. Outside air duct in conditioned space: R -7 with vapor barrier. Exhaust duct inside build = none, in attic = R-4. 2006 WSEC, table 14- 5 and 2006 WSVIAQC. 4. DUCT SEALING - GENERAL: 0 to 2" static pressure - seal all transverse joints on all ducts. Above 2" -seal seams & joints. Inside build: DuroDyne "DDS-181" gray or approved equal per UL 181 A -M, 181B-M listed. Outside: Polyurethane, Mameco Vulkem 116. OR approved equal. 5. TURN VANES: Provide single thickness turn vanes (see detail) in all major square duct elbows, tees, or turns with inside radius less than 3/4 duct width. Square branch duct taps shall be 45 degree type per SMACNA standard. 6. FLEX DUCT (Insulated): For grille run outs up to 6 ft. long, except as noted. Provide adjustable metal elbows on all turns, unless a smooth full radius turn is made. Secure core with approved nylon or metal worm drive clamps. NO duct tape joints & screws allowed. 7. SOUND LINER: Provide sound lined metal supply & return ducts as shown on plans. Manville Permacote Linacoustic flexible fiberglass liner, with acrylic surface treatment or equal. Fabricate and install per duct liner standard of North American Insulation Manufacturer's Assoc. 8. FLEX CONNECTORS: Provide on all duct hook -ups to isolate air handling equipment. (Neoprene coated fiberglass fabric type) 9. DUCT SIZE CHANGES: Round galvanized ducts may be substituted for rectangular ducts that are NOT LINED. Provide circular equivalent of rectangular duct. Other equivalent rectangular duct sizes may be substituted to better fit space. 10. TEMPORARY DUCT CLOSURE: Seal off ductwork during construction to keep out construction dust, especially floor boots and low wall openings. SYSTEM DESCRIPTION Shell and core HVAC systems only. Core HVAC system and restroom exhaust. Classic VAV system for Office space using two rooftop VAV units with gas heat for pre -heat and morning warm -up. VAV boxes with electric heat where needed in offices to be installed under tenant improvement - not included in this scope of work. Type of boxes and control system to be determined. DESIGN CRITERIA OUTSIDE CONDITIONS 85 °F Dry Bulb (DB), 66 °F Wet Bulb (WB) INSIDE CONDITIONS 75 °F Dry Bulb (DB), 63 °F Wet Bulb (WB) INTERNAL GAINS Lighting = 1.25 Watts/SF Equipment = 1.25 Watts /SF People = 125 SF/Person (245/205 Btuh /person - sens/latent) BUILDING ENVELOPE Wall U -0.10 Roof U -0.03 Glazing U -0.50 Glazing SC -0.45 (SHGC -0.40) SC = Shading Coefficient; SHGC = Solar Heat Gain Coefficient REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal c :I nay i7:-,:ude additional plan review fees. FILE COPY Permit No.. tktodP.c:2 Z Plan review approval is subs to errors and moons. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field and conditions Is adcnowledged: BY Date: 26 /o City Of Tidcwita BUILDING DIVISION HVAC LEGEND SYMBOL AH -1 -►- 0 ABBV. DESCRIPTION Control Equipment Grille/Louver SL VD FC Supply Duct Return/Exhaust Duct Duct under slab (Spunstrand) Flex Duct, insulated, inside dimension Metal Duct Soundlined Duct Volume Damper Flex Connector TV Turning Vanes End Cap Change in duct size Surface Mount Supply Grille T -bar Supply Grille Round Supply Grille Return/Exhaust Grille Sidewall Supply /Makeup Grille Sidewall Return/Exhaust Grille FD Floor Drain AFF Above Finished Floor AT Air Transfer BS Birdscreen OSA Outside Air RA Return Air SA Supply Air GRILLE CALL OUT LEGEND Neck Size (IN) Square or Rectangular Grille Tag Number of Slots Grille Tag 8/8 8 140 Neck Size (IN) Round Air Quantity (CFM) Indicates Slot Type Grille Slot Size (IN) Length (FT) Air Quantity (CFM) Air Pattern - indicated by arrows for ceiling grilles. No Arrows indicated four way pattern. DUCT CALL OUT LEGEND (Example call -out shown) 14/10 -1 Lined metal duct, outside duct size given. Number after dash is liner thickness (irk 14/10 Metal duct size. 14 Round metal duct. AIR QUALITY AND ENERGY CODE These plans comply with the 2006 Washington State Ventilation and Indoor Air Quality Code and the 2006 Washington State Energy Code. DRAWING INDEX M1.0 HVAC Schedules and Legend M2.0 First Floor HVAC Plan M2.1 Second Floor HVAC Plan M2.2 Roof HVAC Plan M2.3 HVAC Sections and Details REVIEWED FOR CODE COMPLIANCE Apps- :DYED Mart 0 8 2010`' 'D City of Tukwila BUILDING DIVISION PROJECT LOCATION �200m 1 <600 ft .t o VICINITY MAP SCALE: NONE MIOO22 200S N VTEQ RECEIVED FEB 16 2010 PERMIT CENTER W 0 4 > 1 11'- 4 0 W C: \Documents and Settings \Natalie Thrower \My Documents \Projects \00101 Segale Two Story\00101M2.0.dwg, 2/5/2010 4 :03:47 PM, NMT L O j L_ N 0 SKYLIGHT TERMINATE FOR FUTURE TENANT CONNECTION, NOM. 9000 CFM 48/24 -2 UP 40/32 -2 qP • 32/40 -2 TAIR #1 112 DS -1 32/40 DS -1 50/24 MIN. 3' -0" LINED DUCT BEFORE FIRST DUCT SILENCER L— 6 PROVIDE 12" HIGH METAL GRILLE CAN, TYP. 18/18 SOFFIT 10 PLACE • FUTURE OFFICE 0 1 - SKYLIGHT 10 16/16 OPENING IN RA PLENUM WITH 1/2" BS 16/16 -1, MIN. 3 FT. LONG L- EF -3 10 \ E 161) sA FUTURE TI 6/6 STAIR OPENING i © 50 4 20/14 -1, MIN. 3 FT. LONG 14/14 8/8 CEILING 150 30/14 OPENING IN RA PLENUM WITH 1/2" BS 1- n /E A.T. MN 11 ELECTRIC -WATER HEATER, SEE PLUMBING DRAWINGS 12 "0 U ELEV. ELECT. 10/10 300 12 "0 UP 30/1 WITH OPENING /2" BS L_ MIN. 6 FT. LONG --" INSULATED FLEX DUCT ON A.T., TYP. 8 A.T. 16 "o UP SKYLIGHT z FIRST FLOOR HVAC PLAN SCALE: 3/32' =1' -O' 30/14 OPENING WITH 1/2" BS, 900 TO 1000 CFM EF -2 0 DS -1 - - - --- 32/40 TERMINATE FOR FUTURE TENANT CONNECTION, NOM. 9000 CFM 48/24 -2 UP 32/40 -2 DS -1 50/24 MIN. 3' -0" LINED DUCT BEFORE FIRST DUCT SILENCER STAIR 40/32 -2 UP F.P. 111 11 PASSAGEWAY] i 104 d -0 e 1 izi J REVIEWED FOR CODE COMPLIANCE APPROVE b1Ati 0 8 2010 City of Tukw la BUILDING DIVISInM 2 RECEIVED FEB 16 2010 PERMIT CENTER 4, ' 0 WASgJ,ye* •1 ■ 13387 w4 0 A 6o dECISTEI.12 ,,F 625 FOURTH AVE 1_I__ ill 0 I'H IL I over < 0 III (J) IL L.1 N a W a PERMIT SET A A C�7 w A 0 7 in 0 N 0 JOB NO. 00101 SHEET M2.0 C: \Documents and Settings \Natalie Thrower \My Documents \Projects \00101 Segale Two Story\00101M2.1.dwg, 2/5/2010 4:04:44 PM, NMT O • 28/18 -1 SA DROP MIN. 4 FT. OF LINED DUCT \ / \ / \ 2818 -1 / \ UP\ TERMINATE RA IN CEILING VOID SPACE MEN STORAGE ROOM PLAN C6) SCALE: 3/32' =1' -O' AT ROOF LEVEL O Oi 0 SKYLIGHT o- Q s 9 4 } 36/32 -2 UP TERMINATE ABOVE CEILING FOR FUTURE TENANT CONNECTION, NOM. 9000 CFM 36/32 -2 DN 40/32 -2 DN DS -1 3W36 • STAIR #1 DN MIN. 3' -0 ", TYP 36/36 -2 UP Al &WIZ 36)36 -2 J LINE OF ROOF CURB ABOVE DS -1 36/36 L_ Q FUTURE OFFICE 201 \ FUTJURE STAIR OPEflNG A DN 12 "0 DN 10 SKYLIGHT 12 "0 UP TO EF -3 20/14 i1, MIN. 3 FT. LONG 12 8/8 150 M N j ELEV. 1( #1 6/6 50 30/14 OPENING IN RA PLENUM WITH 1/2" BS DS -1 36/36 30/14 OPENING WITH 1/2" BS 16 "0 UP, TO EF -1 12 "0 DN We.:EN EF -2 MIN. 3' -0 ", TYP. 36/36 -2 -UP DS -1 36/36 36/32 -2 UP TERMINATE ABOVE CEILING FOR FUTURE TENANT CONNECTION, NOM. 9000 CFM \MONO LINE OF ROOF CURB ABOVE MIN. 6 FT. LONG INSULATED FLEX DUCT ON A.T., TYP. /8 A.T. 150 18 "0 UP, 16 "0 DN SKYLIGHT .pi Q 6 30/14 OPENING WITH 1/2" BS, 900 TO 1000 CFM SKY GM SECOND FLOOR HVAC PLAN SCALE: 3/32' =1' -0' u REV1EWED FOR CODE COMPLIANCE MAR 0 8 2010 City of Tukwila BUILDING DIVISION RECEIVED FEB 16 2010 PERMIT CENTER C4 v (4: ;r 2t5 Gz 4 °4. 133874'o_ *QIST01Pr14 SUITE 202 = R A N K L I N KIRKLAND, 1Ul4 95033 II U (IH IL VAC TWO S-1 Andover kwila, WA 0 r� V J m N N a IL W a PERMIT SET O Q 0 in 0 N 0 JOB NO. 00101 SHEET M2.1 C: \Documents and Settings \Natalie Thrower \My Documents \Projects \00101 Segale Two Story\00101M2.2.dwg, 2/5/2010 4:05:13 PM, NMT 0 • I! SLOPE 4" CONC.SOLATION I PAD ON METAL DECK'G CD 0 SLOPE 0 SINGLE PLY ROOFING ON RIGID INSULATION ON METAL DECKING SD 1200 LBS EF -3 100 LBS AC —3 1 Ari MECHANICAL SCREEN PER ARCHITECT, MIN. 4 FT CL AROUND UNIT, TYPICAL CRICKS STAIR #2 RO1 d 4" CONCRETE ISOLATION PAD ON METAL, DECKING, MIN. 3 FT LARGER THAN EQUIPMENT, 1 OICAL SLOPE SLOPE w 0_ I1 1 22 GA. PREF!NISHED METAL COPING ROOF HVAC PLAN SCALE: 3/32' =1-0' REVIEWED FOR CODE COMPLIANCE APPROVED AK 0 8 2010 City of Tukwila BUILDING DIVISION �t• p_pZZ RECEIVED FEB 16 2010 PERMIT CENTER k 0,. ..., ..: 1, - \ , 46 111R7 ! 6n FOURTN AVE 4111-= ') OY) ILI 0 'fH VAC 1 00 Andover 1 4 V r� VJ m N a W a PERMIT SET gv' a w a 0 in 0 N O JOB NO. 00101 SHEET M2.2 C: \Documents and Settings \Natalie Thrower \My Documents\_Projects \00101 Segale Two Story\00101M2.3.dwg, 2/5/2010 4:05:36 PM, NMT loti roar- 7 a 2'— If r '. TR N CO N 1 TR / L i FLEX CONNECTION FACTORY ROOF CURB 10" CONCRETE ROOF 4" CONCRETE PAD, EXTEND 3 FT BEYOND EDGE OF CONCRETE CURB 2" DUCT LINER INSIDE CONCRETE CURB 32/36 -2 TERMINATE FOR FUTURE TENANT CONNECTION, TYP SECTION AT MECH. SHAFT SCALE: 1/4' =1' -0' LOOKING NORTH ♦�♦•O i�Oi•d0No % %i%% %i • i'. d • i • i!.! aO�I� O�Oe 1. e! i! •! ♦! O.l. :!. :O! sO�i �ti00 r! Q y • FLEX CONNECTION WOOD NAILER GLASS FIBER INSULATION PREFABRICATED STEEL CURB ROOFING, FLASHING AND COUNTER FLASHING BY OTHERS. BACK DRAFT DAMPER DUCT TRANSITION � AS REQUIRED. ROOF EXHAUST FAN DETAIL SCALE: NONE U- N I N M TR N N 00 1 N N • 0 FACTORY ROOF CURB, 14" HIGH 10" CONCRETE ROOF CURB �' •• SSZSM�%d�e.6yS�i69i0♦iiiw RA PLENUM IN ROOF CURB, MIN. 22" CLEAR 2' -0" DS -1 24/50 TURNVANES, TYP. DS -1 40/32 SECTION AT MECH. SHAFT SCALE: 1/4' =1-0' LOOKING WEST 2" DUCT LINER INSIDE CONCRETE CURB / 1 1 1 1 FLEX CONNECTION DUCT CURB RIGID INSULATION UNIT ■ UNIT GASKET 2" STATIC DEFLECTION ISOLATOR & EARTHQUAKE RESTRAINT PERIMETER FLASHING BULB SEAL WOOD NAILER ROOFING MATERIAL (BY OTHERS) CANT STRIP ROOF DECK CAULK ALL CRACKS THRU ROOF DECK (NOISE CONTROL) FILLER ISOLATION CURB DETAIL SCALE: NONE 36/36-2 FRONT VIEW — i 1 1 / / 18 GA. GALV. STEEL HOOD OVER RA OPENING WITH 2" LINER ON BACK FOR SOUND ATTENUATION REVIEWED FOR CODE COMPLIANCE AM MED 0 8 2010 SECTION AT 2ND FLR RETUR SCALE: 1/2' =1' -O' LOOKING SOUT MloO1i City of Tukwila BUILDING DIVISION RECEIVED FEB 16 2010 PERMIT CENTER w • 4 4 it�ii, . • VP' �L- .16__ 13387 al I lions & 00 Andover 1 Q PS /SB W 1 a PERMIT SET .. a v' w a 0 in O N O JOB NO. 00101 SHEET M2.3