Loading...
HomeMy WebLinkAboutPermit M10-025 - NTR METALSNTR METALS 814 INDUSTRY DR M10 -025 Parcel No.: 2523049015 Address: Suite No: Cityk Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 814 INDUSTRY DR TUKW MECHANICAL PERMIT Permit Number: M10 -025 Issue Date: 04/06/2010 Permit Expires On: 10/03/2010 Tenant: Name: Address: Owner: Name: Address: NTR METALS 814 INDUSTRY DR , TUKWILA WA WALTON CWWA TUKWILA 1 LLC C/O CTMT - WALTON RE TAX , 4678 WORLD PARKWAY CIR Contact Person: Name: KATIE RUSSELL Address: 814 INDUSTRY DR , TUKWILA WA Contractor: Name: OWNER AFFIDAVIT - KATHERINE J. RUSSELL Address: Contractor License No: Phone: Phone: 206 - 574 -4653 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL (1) 3X3' EXHAUST HOOD AND 12" DUCT WORK TO AND OUT OF ROOF. Value of Mechanical: $725.00 Type of Fire Protection: AFA Fees Collected: $172.06 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial 0 0 0 0 0 0 0 0 0 0 0 1 0 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment0 * *continued on next page ** doc: IMC -10/06 M10 -025 Printed: 04 -06 -2010 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M10 -025 Issue Date: 04/06/2010 Permit Expires On: 10/03/2010 Permit Center Authorized Signature: A ,1 Lki ii it .1 Date: o4Gsctti/c) I hereby certify that I have read and e - d this permit and know the same to be true and correct. All provisions of law and ordinances ' governing this work will be complied ., • -4 er specified herein or not. The granting of this permit d• not pr o give a � • to violate or cancel the provisions of any other state or local laws regulating construction or the perf •_ ance of work. a . o ed to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M10 -025 Printed: 04 -06 -2010 Parcel No.: 2523049015 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 814 INDUSTRY DR TUKW NTR METALS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10-025 ISSUED 02/17/2010 04/06/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation; of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10 -025 Printed: 04 -06 -2010 City bf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presuu e to giv city to violate or cancel the provision of any other work or local laws regulating construction or the performance of wo . Signature: Print Name: Date: 0,171; / 6A- 0/6 doc: Cond -10/06 M10 -025 Printed: 04 -06 -2010 CITY OF TUKWILL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://Www.ci.tukwila.wa.us Mechanical Permit No. AAt 0 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE, LOCATION Site Address: 814 Industry Dr. Tukwila, WA 98188 Tenant Name: NTR METALS Property Owners Name: Walton CWWA Tukwila 1 LLC c/o Walton RE TAX Mailing Address: 4678 World Parkway Cir. King Co Assessor's Tax No.: 2523049015 Suite Number: Floor: 1 New Tenant: ❑ Yes ❑..No St. Louis MO 63134 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Katie Russell Day Telephone: (206) 574 -4653 Mailing Address: c/o NTR Metals 814 Industry Dr. Tukwila WA 98188 City E -Mail Address: krussell @ntrmetals.com State Zip Fax Number: MECHANICAL CONTRACTOR INFORMATION Company Name: NTR Metals - Affidavit in Lieu Of Contractor Registration Filed Mailing Address: 814 Industry Dr Contact Person: Katie Russell Tukwila WA 98188 E -Mail Address: krussell@ntrmetals.com Contractor Registration Number: n/a City State Zip Day Telephone: (206) 574 -4653 Fax Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: NTR Metals Mailing Address: Contact Person: E -Mail Address: city Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: NTR Metals State Zip H:1Applications \Forms- Applicatioas On L nc\2009 Applicmions11-2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 1 of 2 • Valuation of Project (contractor's bid price): $ 725 Scope of Work (please provide detailed information): Install one 3'x3' exhaust hood and 12" duct work to and out roof. Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct 1 Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY WS OF THE ..: TE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 1 ' AUTHORIZED AGE Signature: Print Name: Day Telephone: Mailing Address: F121 J_ ��� S D/ Lt/i ( / 0. 4,/4- qn G ri-- State Zip Date: t.6 /6,/ y • Date Application Accepted:I nko Date Application Expires: II � r Staff Initials: /1 H:\ApplicationsTorms- Applications On Line t2009 Appl.cations\l -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh ATTACHMENT #1 SCOPE OF WORK FOR MECHANICAL PERMIT NTR METALS 814 INDUSTRY DR. TUKWILA, WA 98188 The following Mechanical work is proposed for the above listed address: 1) Install one MU1200 Melting Unit (CE Listed) 2) Install one 4' x 7' Type II Manufactured Heat / Fume Exhaust Hood above Melting unit. with 12" ducting through roof. Duct pipe to extend min 3' from roof surface and to covered with a conical cover. Duct to be fitted with 2280 cfm 110v fan at vent hood. ano�uiEC°wau► FEB 1J 2010 PERMIT CENTER OP of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R10 -00277 Initials: JEM Payment Date: 02/17/2010 User ID: 1165 Total Payment: 401.89 Payee: WAYNE MCDONALD SET ID: S000001349 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D10 -045 EL10 -0115 M10 -025 TOTAL: 150.03 79.80 172.06 150.03 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA - - - 401.89 TOTAL: 401.89 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.322.101.00.0 000.322.102.00.0 000.345.830 640.237.114 88.20 79.80 137.65 91.74 4.50 TOTAL: 401.89 PAYMENT RECEIVED INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA -98188 INSPECTION RECORD Retain a copy with permit M -02S PER�� (206)431 -3670 Project: r itteherif Typ f Inspe do A t Add*sis:4 6 `/ i 4012_„Date Called. Special Instructions: . Date Wanted: 4-�3 -(0 a.m. Requester: Phone Nob /s 71 `1 653 Nri4, Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Receipt Af REINSPECTION FEE ' QUIRE J3 Prior to inspection, fee must be 6300 Southcenter Blv. ., Suit 100. Call to schedule reinspection. f-2, o.: Date: te v...rloXhaftirth.k:(441110.1rattriagd. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION =_ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit A110 -02-5 FT NO. Project.,� Type ofAnspectioq: _ i midi I , Address: /-.4 ./Ad.uts-Plry .,oe Date Called: Special Instructions: )/3' host -s Ifo �J v 71n tZ ,� 0 J � I OF- /. G %S� /0 pm/ Requester: Phone No: to —In / ^"-lXid { Approved per applicable codes. Corrections required prior to approval. COMMENTS: Xij44 0.'l ,ii � L&/ JAS 1 /I)61,h -' 4l -r 4Y#VeL/ or: Date: /v 00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be at 6300 Southcen er Blvd., Suite 100. Call to schedule reinspection. e1-€ipt No.: Date: AE ENGINEERS, INC. 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425)739 -8051 April 13, 2010 Dave: Katie Russell asked me to write you a letter concerning only wrapping their duct within 18 inches of combustibles. Since the installation does not strictly fall under the circumstances that cover type 1 hood ie a grease hood I feel that some latitude can be exercised in the requirements. In addition, the code states that the local code authority is the ultimate authority on installations. With these facts in mind it is felt that having the duct wrap only within 18 inches of combustibles would constitute a reasonably safe instillation. Please call me at 206 - 498 -8261 (cell) or 425 - 739 -6051 (office) if you have any questions. Sincerely, John Beebe, P.E. Principal, AER Engineers Cc: Chris Reed RECEIVED APR 212010 PERMIT CENTER /L PE INDEX OF DRAWINGS 1 -1 COVER 1 -2 SITE 1 -3 MECHANICAL DETAIL 1-4 MECHANICAL FLOOR PLAN 1 -5 PROPOSED VENT LOCATION ROOF PLAN PERMIT/PLAN PURPOSE MECHANICAL PERMIT Location Of Jobsite z0/fit i6 ;4 l DESCRIPTION 1 III' /' L TO AID MELTING UNIT, HEAT/FUME EXHAUST HOOD AND DUCT TO VENT OUT ROOF Perm ft N�+. OTT LC* E SET to Dst i--as, MO tk 3eNt 3 5asISe•m NOS: 410kCeetitiff Rezix.re: tt r ti a`s 6;tv ,iiynna• Come eroui Coq,' 'CC height:Micc "Introtoiat Cerro 4C Regicnt ^NnTeraa, SCLI ReTiortal Cwrfrerclai Limed Joe -JC Ta Ba ;Am Cep•► at. Ccr.r•ewal.gb'Ina.14.0 ro'S licsv$a '4_741 Snot L L4,1 (1114.74 i' ku'4 Altatt aI ►ACY VoNlicoong Atikt Mal CevRePt r, *lama A *i n+i Moneltr riti 1 ei esmoi Cor..er, Leavy t,dics7fal Overlays and Sslb Arpaut soioWava eta Cety 4rta R.to: Heave arariey St wens Overlay tArros natty 2X ea s:actt►e•r.r: 1 REVIEWED FOR CODECOMPLIANCE APPROVED APR 0 5 2010 CftyofTukwila BUILDING DIVISInM BUILDING 18 800 INDUSTRY DR AREA OF WORK 14000 SQUARE FEET INITR MET LS 814 INDUSTRY DR, TUB ILA, lA 98166 PAGE 1 OF' 'ERMIT CENTER; E VED crr R0 TUKVIALA FEB 1� .71;010 N3O 11WH1 NTR METALS N CityGIS i . 1 66 ft Copyright 0 2006 All Rights Reserved. The information contained herein is the proprietary property of the contributor supplied under license and may not be approved except as licensed by Digital Map Products. , 0 02/16/2010 g F-- 0 = I,. 20 rn331 ' co 04: --r3 410 mic z 0 , 19 0 Fn- G) -.'" c, 0* 0 Crn NA ik = n = c:3 \k W'. . C(10cd Pt- L,t(4 u (O 'tb A L 1) l- '1wok,t, I REVIEWED Fp i CODE COMPLIANCE APPROVED APR 0 5 2010 Rroi City of Tukwila BUILDING D+ +S . ON t'L A m . M610-L 1 4 c° R ' x S F4D01� cAa f-t i / c l(aoQ i mti'l�[ t istt1 90' \11r'W`, fc o 1 ( 41 'M c4 c ocf We clkof to*r cnY oTuEKfm)IA FEB 17MO PERMIT CENTER / -'3 .\:\eCiAaOtCAL- UE NI- e +44k5 i 4-00C-1-11017 S14 INm95.104hL"DQ,,--twtw►i-N- ,wt giNtip ,4ca.(14, t14t`= 1` 02— die -2o�D N'[tL 141r1A -lA I%RA, 3 a-5 w � c cn 8' -2 33 0) 1/4" r 4' -4' 5.3 7:2 "x 4' -8' FRONT OFFICE AREA 9' -4" 1'-11 1/8"-1 1, /r c,,° 0 0) 7' -6 1/4" WAITING AREA PROPOSED IMPROVEMENT - MECHANICAL FOR 814 INDUSTRY DRIVE, TUKWILA, WA 98118 70' -1" BACK OFFICE AREA 11' -11 11/16" ►!m 2' -8_'I 6 5/81 2' -8 "•-■ 7'_9" ® gyp! I (456 ' : E'.6 ,.6'n 4_n ' HALLWAY 1- 7 3/1,x+13' -8 5/8" - 4' -9 3/8" 11' -8 1/ " rn enzerrommesumnam r 2' 6' r 6'8' • 2'-4' a CO N BATHROOM c ? 4 70' -1 3/8" 7 2." puc.-v PROPOSED EXHAUST VENT HOOD 4'X 7 WITH 12° PIPE OPENING & INUNE 2280 CFM FAN 66' -0 1/4" WAREHOUSE AREA 12" VENT PIPING TO ROOF VENT REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 5 2010 City of Tukwila BUILDING DIVIcinni 20' -0 13/16" PROPOSED MECHANICAL IMPROVEMENT 814 INDUSTRY DR., TUKWILA, WA 98188 SCALE: 3/116 " = 1' 02 -16 -2010 / PAGE ( OF crtvoSu FEB 17 2010 PERMIT CENTER : 4 PROPOSED VENT LOCATION ROOF PLAN FOR 814 INDUSTRY DR. - TUKWILA, WA 98188 70'-1" FRONT OFFICE AREA 2/1 01-,t,-;,91-/C1 S-1 WAITING AREA BACK OFFICE AREA BATHROOM V HALLWAY 70' -1 3/8" WAREHOUSE AREA PROPOSED NEW ROOF VENT FOR MELTING UNIT EXHAUST NATURAL GAS WAREHOUSE HEAT VENT CODEIEWED FOR COMPLIANCE APPROVED APR 0 5 2010 � � Tukwila City BUILDING DIVI,4Iniv -20'-0 13/16" 1 I op BATHROOM VENT 66' -0 1/4" PROPOSED VENT LOCATION ROOF PLAN 814 INDUSTRY DR.,TUKWILA, WA 98188 SCALE: 3/16" = 1' PAGE > OF 02 -16 -2010 cmoRCKEDwnLn FEB 172010 PERMIT CENTER IN UTHE Erwiarmungsanlagen GmbH P�'�ait No. Instruction Manual for Melting Machine MU 400 to MU 1200 REVIEWED FOR CODE COMPLIANCE APR 0 5 2010 BUILD G of DIVI.SInm INDUTHERM Erwarmungsanlagen GmbH Brettener Strasse 32 D -75045 Walzbachtal Germany INCOMPLETE LTR# RECEIVED' MAR 242010 PERMIT CENTER Tel.: +49 7203 9218 -0 Fax: +49 7203 9218 -70 e -mail: info @indutherm.de BEDIENUNGSANLEITUNG, MUt00_BIS MU1200_8X8XX GB.DOC 04.12 2009 KS A INDUTHERM Contents 1. Introduction 3 1.1. General description of the MU melting machines 3 1.2. Machine components 3 1.3. Technical data 4 1.4. General information 5 2. Putting into operation 7 2.1. Set -up directions 7 2.2. Mains supply 7 2.3. Cooling water 7 2.4. RS232 connector 7 3. Operation 8 3.1. Operating elements 8 3.2. Casting 9 4. Service 10 4.1. Trouble shooting 10 4.2. Thermocouple connection / parameter setup 10 4.3. Maintenance 11 5. Connection diagram 12 6. Appendix 13 6.1. Spare parts list 13 6.2. Assembly drawing MU- series 14 6.3. Declaration of Conformity 16 6.4. System parameter and error codes 17 INDUTHERM 1. Introduction 1.1. General description of the MU melting machines With this melting machine, the melting charge is heated up by induction. The special advantage of inductive heating is that the melting temperature is reached rapidly, because the heat is directly generated in the metal and in the crucible. During the melting process, the metal is thoroughly mixed by means of a magnetic field, ensuring a homogenous mixing even when using new alloys. Installing the thermocouple in the crucible bottom allows an exact temperature measuring and also the output of the unit is controlled in such a way that the set temperature remains constant. 1.2. Machine components The machine consists of separate units built into one casing: 1 Inside the casing, the following components are installed: - mains supply and mains fuses (automatic cut -out) microprocessor controlled induction generator medium frequency transformer - oscillation circuit capacities 2. The front panel consists of: - operating panel for control of melting cycles 3. The casting unit consists of: inductor, crucible, insulation parts, thermocouple (� 1.3. Technical data INDUTHERM : MU1200 Crucible volume Crucible temperature Melting performance Cooling water recoil Cooling water entry temperature Room temperature 400 cm 6 k. /Au 700 cm 9 k. /Au 900 cm �13k. /Au max. 1500 °C with type S thermocouple 10 kW 3 *400 V /20 A, 50 or 60 Hz 3 * 208 V/32 A, 50 or 60 Hz o • tion 2.5 - 6 bar /at least 2001/h without pressure 15 — 30 °C 10 — 35 °C 20 -80% 1200 cm 18k. /Au 500 mm * 500 mm * 900 mm :� INDUTHERM 1.4. General information Safety information In order to ensure a constant, ideal performance of the machine and to ensure safe working conditions, the user is to observe the following safety measures: • The complete electrical wiring is to be performed only by qualified and specially trained personnel. • Check the machine and the supply devices regularly on possible damages. • When opening cabinet/casings or when removing parts (exception: when this is possible by hand), certain parts under electric power can cause danger. If opening up the machine is necessary (before maintenance, change of machine settings, repair or exchange of parts) the machine must be cut off the mains voltage. If working on the opened machine is inevitable, only qualified trained personnel aware of the danger caused hereby and aware of the relevant regulations may be instructed to do this work. • Capacitors in the machine can still be charged even when the machine's mains supply is switched off. • When it seems that the machine can no longer be worked safely it has to be taken out of production and secured against further unintentional use. The following incidents indicate that safe working is no longer possible: - the machine is visibly damaged - the machine does not function - uncommonly heavy wear from transportation • The safety valves placed inside the machine casing may not be removed, closed or altered in any way. • As melted metal is processed with this machine (= temperatures up to 1500 °C), the utmost care and attention has to be applied when working with the Machine. The following necessary safety clothing is principally to be worn: - fireproof clothes - fireproof closed shoes - fireproof gloves - safety goggles • Special caution is essential when working with graphite crucibles and graphite dies because these are only visibly hot at temperatures above 500 °C! • In commercial enterprises the regulations for the prevention of accidents of the relevant authority for electrical machinery are to be followed. • People with pacemakers must not be near the machine while it is running. INDUTHERM • A trained responsible personnel is to supervise work with this machine. Use as determined /liability This casting machine is designed and manufactured to comply with the latest technical knowledge and according to approved safety regulations. When not putting into operation correctly or not using the machine as determined, however, danger and damages may occur. Therefore we suggest reading carefully and completely this manual before putting the machine into operation and to follow the instructions given therein: • This machine is only to be used for melting, casting and granulating of precious metals normally used for the production of jewellery. • This machine may only be connected as mentioned in this manual. The mains supply as well as in- and outgoing pressures are to be provided as stated on the machine label. • This machine was designed for use in closed spaces (indoors) and may only be used for the above - mentioned purpose. • Only original INDUTHERM consumable and spare parts are to be used. • The machine may not be modified in any way. Technical changes may only be effected with INDUTHERM GmbH's prior written permission. • Damages caused by disregard or false interpretation of the contents of this instruction manual result in an immediate expiration of the machine guarantee. • This instruction manual is conform to the latest technical condition of the machine when printed. Technical changes and fittings subject to change. • INDUTHERM GmbH cannot and will not take responsibility for any damages resulting of the above mentioned. • This instruction manual may not even partially be reproduced (photocopy, micro film, computer processing etc.) without prior written permission of INDUTHERM GmbH. 2.3. Cooling water Use two hoses with an inner o of 8 mm for the cooling water. The water entry pressure must be at least 2.5 bar and must not be more than 6 bar. The water drainage must be without pressure. The water entry temperature must be above 15 °C and must not exceed 30 °C. The concentration of lime in the water must not be more than 60 mg CaO /I. The cooling water must not be contaminated. Caution: As long as the crucible temperature is above 100 °C, the cooling water supply must be open; otherwise the inductor insulation could be destroyed. In case the cooling water supply stops while there is still a hot crucible inside the machine, the crucible must be removed once. 2.4. RS232 connector At this connector our modem article no. 71000320 or the serial cable article no. 50500060 can be connected INDUTHERM 3. Operation 3.1. Operating elements Temperature: Normally, the actual crucible temperature is indicated here. When pressing the buttons " +" or " —" the indication changes to the set -point value (nominal value) for at least 5 seconds. An active set -point value is indicated through an illuminated red decimal point. The set -point value can be altered with the buttons " +" or " - ". Water: This signal Tamp illuminates when the water entry pressure is more than 2 bar. If the water pressure is too low, the signal Tight extinguishes and the generator is stopped after some seconds. The display shows error and there is an acoustic error signal. Program: It is possible to store up to 16 temperature values (1 -9 and A -F). To store a new value: 1. Select a program number (1 -9 and A -F) with the pushbuttons ' +' or ' -' (field Program). 2. Adjust the temperature value with the pushbuttons ' +' or ' -' (field Crucible Temperature). 3. Press the pushbuttons ' +' and ' -' (field Program) simultaneously at least 1 second. Now the new temperature value is stored. Power: -Button Start / Stop: The generator is turned on /turned off with this buttons. The turned on generator regulates principally to the adjusted nominal temperature (see Crucible - Temperature). -Button + / -. The maximum generator power is selected with this buttons Other error codes: see appendix 4.2. Thermocouple connection / parameter setup Type K / NiCr -Ni: Green wire connected to X6, pin 1. White wire connected to X6, pin 2. Parameter: Al = 000, F6 = 114 Type S / PtRh -Pt: Orange wire connected to X6, pin 1. White wire connected to X6, pin 2. Parameter: Al = 001, F6 = 110 INDUTHERM 4.3. Maintenance A routine check/regular cleaning of the following is necessary: (Caution: disconnect the machine first!): Daily (before casting): 1. Remove thermocouple, crucible and insulation materials, carefully clean inductor housing with a vacuum cleaner. Before reinstalling the above parts, check those and replace if necessary. Annually: Depending on the water quality, the cooling system should be cleaned with 25% citric acid. The cooling system should be treated with this acid for approx. 1 hour. Then clean the system thoroughly with pure water and check on eventual leakages. 1. Tighten all electric wirings, especially those for power current. 2. Tighten all connections of water - cooling. 1 I 2 1 3 1 4 5 I 6 I 7 I 8 A B C 0 E -' u =6 =, N N c generator E..se ye,era;or ■ith capaCttor (an ... O .rd 1SRT ror -rer hew k).-4. c 68x0.68yF 400u A _ B C 0 E — F r c or 7 , _ Dk �.0 3 ar' ,.o 1 8401 1.2 X1 X8 3 IRO: _ _ _ _. _ _ __ _ __ __ _. __ relay board X101 3 _ _ X102 X9 5 13 X7 X6 4 5 X4 9 ,3 X3 i5 or 2x32x0,68pF 480V bk Ll L2 br C -Batt. 1a>• CEE32A L3 mom N r= iT bk — 5 e x -•- transformer inductor MU100'MU700 : 51588021 (USA: 51500011) *e MU800if41200 • 61575010 (ws ercooled) �- >- 1 �J PE Cam— J 9ry' -- —�. 1 it operator panel D t10 C J thermocouple \ _ water El--,/, _h . 2 Flasklift lower position 2-4,___ [option) Ua:sn.).a,. "a "'`4:� MU400 / MU700 MU900 / MU1200 INOUTHERM Ar:.,,ere, Se•.1, �r,.EaS wsi zt,acs d; wGS ^.'. �,er Wireinq diagram PeF rb + „ppr I�„ 1 ,I _usl Aiwee L-q Oat..n Nara Nor �o Ur spr. 1E, S. £ra. 3. 1 [ 2 l 3 I 4 I I 6 1 I 8 weJ6eip uoipauuo3 •9 Z c 3 INDUTHERM 6. Appendix 6.1. Spare parts list At following side the spare parts list for this machine will start. INDUTHERM is now using only machine specific spare parts lists, which contain all the information for your machine. The list is printed on the following pages. The name of the stored list starts with a 1.) G 2.) The next 5 digits are the machine number. 3.) Next is the specification for what application it is used for. (only at multipurpose machines) 4.) The version index. A new machine has the index 00. One example is G05120_VC_00. This is the list of the machine serial no 05120 and the spare parts shown are for vacuum casting, index 00. We are pleased to send you this data on request as a PDF file G05120_VC_00.pdf. This makes it easy for you to order the correct spare parts. If the list changes and the index get one step higher to 01 please save the old file 00 into a section "old" or delete it. If spare parts are replaced by new parts, the index will be incremented. This ensures that you always receive the latest version of consumables and spares. To be sure that the data is correct, INDUTHERM and their sales partners or end customers must work together. If the machine is used for several purposes like sintering and granulating, more than one list is used for one machine like: G05120_VC_00 All parts for vacuum casting G05120_ CC _ 00 All parts for continuous casting G05120_SI_00 All parts for sintering G05120_GR_00 All parts for granulating G05120_PA 00 All parts for steel and Palladium casting For other spare or replacement parts please contact our sales partner for your country or our order department at the telephone no.: +49- 7203 - 9218 -40. INDUTHERM 6.2. Assembly drawing MU series Cut INDUTHERM MU- Series C083 as one piece glued together C063 C'058 I C()()8 C067 C084 (glue) C'102 C'081 C210 WftatiCkVIW Sittoe .Am .. - alt... . ... mrprac CO22 tc Xf, ;�- ddw .;� bY �r.,aWkr.tiCaSWn61:11Vhr`:.:, C'211 ..Fifas.�mu Very important for correct temperature measurement: Height X = mm is the thermocouple higher then the copper plate xmm MU400 and MU700 x =40mm, MU900 and MU1200 x = 50mm, C'218 IErwarmungsanlagen GmbH INDUTHERM Erwarmungsanlagen GmbH Brettener Stra(3e 32 75045 Walzbachtal Germany Telefon: +49/72 03/92 18 -0 Telefax: +49/72 03/92 18 -70 Order -list for spare parts MU1200 serial no.:10030 customer 500NTR1 Order from: your customer no.: your customs no.: your order no: G10030_00 21 01.2010 Pos. ' Art. -No. ' Qty. , Unit i Description ' Picture C083 10075906 ' pcs graphite crucible + ceramic shell for 1 MU1200, graphite 0o= 116mm� -•'` 0i =96mm, isolated for temperatures up to 1400 °C, no hole, standard quality Q =0101, quantity =l5kg, C058 11175012 I pcs I crucible cover ceramic MU1200 with new quality Q =8401, C063 11175030 i pcs isolation ring for MU1200 CO22 ;11275010 j :pcs crucible bottom insulation MU1200 up';; to 1300 °, h =25mm, 0= 150mm; °'s� C082 10878010 ' pcs thermocouple protection cover TM200 „4n,e ,k , i 1 graphite 2 n .,4 C051 i 12117010 pcs sealing rod tube D15x282 GUNC3000 and for CC3000 granulating, ceramic material Q =5000, C070 13178010 , I pcs I I ! ;thermocouple type K with connector for ' Ar'' 1TM200. Up to temperature 1200° Iwo C059 ; 14575010 i , pcs crucible tongs MU1200 C165 86070010 pcs ' manual melting unit MU400_1200_GB with spare parts When you need larger quantities please ask for spezial offers. Customer specific sizes for crucibles /dies are avaibable on demand. INDUTHERM 6.3. Declaration of Conformity Declaration of Conformity Manufacturer: INDUTHERM Erwarmungsanlagen GmbH Brettener Strasse 32 75045 Walzbachtal- Wossingen Germany Tel.: +49- 7203 -92180 Fax.: +49- 7203 - 921870 Machinery description: Melting Machines MU400, MU400V, MU400 VV, M U700, MU700V, MU700VV, MU900, MU900V, MU900VV,```hr' fi'i. MU1200V, MU1200VV declares that the products herewith complies with the requirements of the 98/37/EG (directive on machinery) 72/23/EWG (directive on low voltage) changed in 93/68/EWG 89/336/EWG (directive on electro magnetic compatibility) changed in 2004/108/EG Standards applied: EN 61000 -6-4 EN 61000 -6 -2 and carry the CE marking accordingly INDUTHERM Erwarmungsanlagen GmbH Brettener Str. 32, — 75045 Walzbachtal- Wossingen, GERMANY L Peter Hofmann Dipl. -Ing. (FH) — Chairman Walzbachtal, 23.06.2008 INDUTHERM 6.4. System parameter and error codes At following side starts the current list of System Parameters and Error Codes Attention: On our webside http://www.indutherm.de/errors.html you can find examples how to troubleshoot errors tat • f . ,,.,- COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -025 PROJECT NAME: NTR METALS SITE ADDRESS: 814 INDUSTRY DR Original Plan Submittal Response to Correction Letter # DATE: 03 -24 -10 X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENT : ul (. 0 din Divisio j Public Works Fire Prevention Structural Planning Division Fl n Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete. Incomplete ❑ DUE DATE: 03-25 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 04 -22 -10 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -025 DATE: 02/17/10 PROJECT NAME: NTR METALS SITE ADDRESS: 814 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued //D��.�E�PARTMENT : &6itding `son 5.Q-ID Public Works FVw AVA- ire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: Incomplete DUE DATE: 02/18/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg J/ Fire ❑ Ping ❑ PW ❑ Staff Initials: V( TUES/THURS ROUTING: Building Please Route ❑ Structural Review Required REVIEWER'S INITIALS: n No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 03/18/10 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through Date: G the mail, fax, etc. Plan ChecWPermit Number: Er Response to Incomplete Letter ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: CC L ./ 1/' Contact Person: lt� �- �55P,r' Phone Number: �Qf'p - 2`� - l/6 5 Summary o Revision: / e U d!^a to 1//‘ e v- fn g. a /kit) 'Si %%a Awve° .S5 71 J S �)^ e c v vh < Oci &tea' /� e ( be � ryn � a Is-, i ncllAded A_ 6 O 1 zts cc maw ua.1. ,A)Tg ,rxie.1/46 /Q -(iQS RECEIVED CiTYOFTUK�R ;MAR 2.4 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision 'l Received at the City of Tukwila Permit Center by: 3 2- 1i 0 -1,A C)-J\ Igr Entered in Permits Plus on -23—.)-1A---1, 0 \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: AER March 23, 2010 NTR Metals 814 Industry Drive Tukwila, WA Attn: Katie Russell �a�s.Z INC IH AVE.. ME. (42F)7.I • Dear Katie: The following is Addendum #1 for the NTR Exhaust System: THE CONTRACTOR SHALL INCORPORATE THE FOLLOWING ITEMS INTO THE CONTRACT DOCUMENTS AS IF THEY HAD BEEN IN THE ORIGINAL DOCUMENTS ADDENDUM #1 1. The hood fabricator has stated that the hood ( #18 steel) will weigh approximately 40 pounds. The hood shall be supported with 4 each chains, each with a capacity of 100 pounds. The support shall be installed in a manner to meet all seismic codes. The fire rated chase shall be supported independently and shall not be supported by the hood chains. If the final weight of the hood is more than 40 pounds, the capacity of the chains shall be increased proportionately. 2. A rain hood shall be furnished and installed on the roof exhaust fan. Please call me at 206 -498 -8261 (cell) or 425 - 739 -6051 (office) if you have any questions. Sincerely, John Beebe, P.E. Principal, AER Engineers INCOMPLETE Mao ,i& RECEIVED MAR 24 2010 PERMIT CENTER • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director February 18, 2010 Katie Russell NTR Metals 814 Industry Dr Tukwila, WA 98188 RE: Letter of Incomplete Application # 1 Mechanical Permit Application M10 -025 NTR Metals — 814 Industry Dr Dear Ms. Russell, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 17, 2010 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a "Revision Submittal Sheet" must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, •RclAjtir_ Bill Rambo Permit Technician Enclosures File: M10 -025 W: \Permit Center \Incomplete Letters \2010 \MI0 -025 Incomplete Ltr #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: February 18, 2010 Project Name: NTR Metals Permit #: M10 -025 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 1x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide new drawings drawn to scale. Drawings shall be provided by a design professional, wet stamped and signed by the design professional. Plans shall be complete with details identifying all materials and method of seismically securing the duct. Indicate type of construction of the existing building. Floor plan shall be complete with all dimensions identifying the size of unit and specific dimensions for location and clearances of the mechanical equipment. 2. Provide manufactures specifications and UL listing for the melting unit, hood and duct. 3. Provide complete details for all penetrations through the roof. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431 -3665 E -mail: tukplant ci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) ` ► 1 / )4 , gvissQ_It , states as follows: [please print name] PERMIT NO: t-1 IJ'A,C WO —CO CL o tc 1. -I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requiremen of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number I', and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. to engage an unregistered contractor to perform constru I understand that I may be waiving certain rights that I might 4, erwise - under state law in any decision work. 0' ...a i'41,1 I / /iii 6rf 00N E,r�'4 �� AI lo, y WS 4����OF\W P . �� t Signed and sworn to before me this 1 (.s2 day of k--.e Li--c , 2Oj . NOTARY PUBLIC in and for the State of Washington Residing at County Name as commissioned: , tASU- irccK 10-1q-,901( My commission expires: 18.27.090 Exemptions, The registion provisions of this chapter do not apply t 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor, 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of ahousehold appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. F uc,50i.3 - - Where mechanical exhaust is required in a room or space, such space shall be maintained with a neutral or negative pressure. Adequate make up air consisting of supply air, transfer an or outdoor air shall be provided to satisfy the deficiency. 7/' rti-pr,1 12" HIGH ROOF CURB FLASH, CONSTRUCT, AND SEAL PER LANDLORD'S REQUIREMENTS. RETAIN LANDLORDS ROOFING CONTRACTOR IF REQUIRED BY LANDLORD. 30x12 OSA INTAKE W/ BIRD SCREEN AND BAROMETRIC DAMPER MIN 10' WEATHER PROOF FLEX CONN. e- RAW ti-ooD NOT ..i\ONA/ t\1 11111111111111111111111111111111.111111111.111111111111111111111111111111111111111111111111111111111111111111111111111111111111 4 1-6" 30x12 MAKE—UP AIR DUCT #18 MSG SHEET METAL OVER GYP BD WALL 120 VIBRATION ISOLATORS COORD. W/ STRUCTURAL FOR SUPPORT ROOF \ROOF JOIST ROOF OPENING AND ROOFING. COORD. W/GC TO HAVE LANDLORD'S CONTRACTORS PERFORM THIS WORK AND TO INCLUDE THIS IN THE GC'S BID, IF REQUIRED BY LANDLORD NON—COMBUSTIBLE DUCT SHAFT. SEE DETAIL B THIS SHEET. EXHAUST HOOD 0.043" MIN STEEL (#18 GUAGE) OR 0.037" MIN SS (#20 GUAGE) 30x14 MAKE—UP AIR OUTLET 7'-6" 1.. 11-5— 2 2'-11-1.. 2 FLOOR 14' 1" MELTING EQUIPMENT 1 -6" 1 NOTES 1. CONTRACTOR SHALL INSTALL EXHAUST HOOD AND ALL ACCESSORIES IN CONFORMANCE WITH LOCAL CODES AND SUBMIT SHOP DRAWINGS TO LOCAL CODE AUTHORITY. EX AUST SYST v SECTIO SCALE: 1/4" #18 MSG SHEET METAL OVER GYP BD WALL 2HP FUSED DISC. 3 #12 CU W/GD IN 1/2" EMT TO POWER PANEL 30x12 OSA INTAKE W/ BIRD SCREEN AND BAROMETRIC DAMPER (ON ROOF) l'-6" REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 5 2010 Al- QV of BUILDING 1 '-6" OF MELTING MACHINE-1 MELTING MACHINE 10" EXHAUST HOOD 3 #12 CU W/GD IN 1/2" EMT 2HP NON—FUSED DISC. OF ROOF OPENING NON—COMBUSTIBLE DUCT SHAFT. SEE DETAIL B THIS SHEET. 6-8" WEATHER PROOF FLEX CONN. EXHAUST FAN (ON ROOF) EXHAUST SYSTEM PLA\ SCALE: 1/4" = 1'-0" ISION FILE COPY Permit No. 0,0 -2.2"- Plan review approval is subject to errors and omissions. Approved of construction documents does not authorize the violation of any adopted codetook_uo nce. R: «Apt d) 4 :i 1 ItY of approved Field 1 ons is acknowledged: 0111&IL-K ' By . . . - -■ P ri 4341/14■ ____ .44,‘ 4 t ____ Date: City Of Tu Ila BUILDING DIVISION COPYRIGHT 2010, AER ENGINEERS, INC,. .• 2 LAYERS OF 1/2" WALL BOARD 1—HR CAVITY SHAFT WALL PER IBC. 6" MINIMUM CLEAR ALL AROUND EXHAUST DUCT 2x4 STUD NOTE CONSULT LOCAL CODES AUTHORITIES, INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. FIRE RATED EXHAUST S-AFT CB) SCALE: N.T.S. M-1 • ISEPARATT REQUIRED FOR: 0 Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION EXHAUST FAN SCHEDULE DESIGNATION SERVES MANUFACTURER MODEL CFM RPM SP ELECTRICAL DATA DRIVE NOTES HP VOLTS/PHASE EF-1 MELTING FURNACE GREENHECK SWB-210-20 2500 3350 1.0 2 208V./30 BELT A, B NOTES: A. PROVIDE DISCONNECT SW (TCH (NEMA 3R). B. TOP OF FAN SHALL BE ABOVE PARAPET. (FIELD VERIFY) . REVISIONS No chances shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. INCOMPLETE RECEIVED MAR 24 2010 PERMIT CENTER M1OO2 ,50 AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739-6051 (425) 739-7362 AERI23@AOL. COM A DATE DESCRIPTION ISSUE DATE: CHECKED: DESIGNED: DRAWN: 03-16-10 JOHN BEEBE CHRIS REED CHRIS REED