HomeMy WebLinkAboutPermit M10-025 - NTR METALSNTR METALS
814 INDUSTRY DR
M10 -025
Parcel No.: 2523049015
Address:
Suite No:
Cityk Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
814 INDUSTRY DR TUKW
MECHANICAL PERMIT
Permit Number: M10 -025
Issue Date: 04/06/2010
Permit Expires On: 10/03/2010
Tenant:
Name:
Address:
Owner:
Name:
Address:
NTR METALS
814 INDUSTRY DR , TUKWILA WA
WALTON CWWA TUKWILA 1 LLC
C/O CTMT - WALTON RE TAX , 4678 WORLD PARKWAY CIR
Contact Person:
Name: KATIE RUSSELL
Address: 814 INDUSTRY DR , TUKWILA WA
Contractor:
Name: OWNER AFFIDAVIT - KATHERINE J. RUSSELL
Address:
Contractor License No:
Phone:
Phone: 206 - 574 -4653
Phone:
Expiration Date:
DESCRIPTION OF WORK:
INSTALL (1) 3X3' EXHAUST HOOD AND 12" DUCT WORK TO AND OUT OF ROOF.
Value of Mechanical: $725.00
Type of Fire Protection: AFA
Fees Collected: $172.06
International Mechanical Code Edition: 2006
EQUIPMENT TYPE AND QUANTITY
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
0
0
0
0
0
0
0
0
0
0
0
1
0
0
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment0
* *continued on next page **
doc: IMC -10/06
M10 -025
Printed: 04 -06 -2010
1
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: M10 -025
Issue Date: 04/06/2010
Permit Expires On: 10/03/2010
Permit Center Authorized Signature: A ,1 Lki ii it .1 Date:
o4Gsctti/c)
I hereby certify that I have read and e - d this permit and know the same to be true and correct. All provisions of law and ordinances
' governing this work will be complied ., • -4 er specified
herein or not.
The granting of this permit d• not pr o give a �
• to violate or cancel the provisions of any other state or local laws regulating
construction or the perf •_ ance of work. a . o ed to sign and obtain this mechanical permit.
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -10/06
M10 -025 Printed: 04 -06 -2010
Parcel No.: 2523049015
Address:
Suite No:
Tenant:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
814 INDUSTRY DR TUKW
NTR METALS
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M10-025
ISSUED
02/17/2010
04/06/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation; of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
doc: Cond -10/06
M10 -025 Printed: 04 -06 -2010
City bf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206- 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presuu e to giv city to violate or cancel the provision of any other work or local laws regulating
construction or the performance of wo .
Signature:
Print Name:
Date: 0,171; / 6A- 0/6
doc: Cond -10/06
M10 -025 Printed: 04 -06 -2010
CITY OF TUKWILL
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://Www.ci.tukwila.wa.us
Mechanical Permit No. AAt 0
Project No.
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE, LOCATION
Site Address: 814 Industry Dr. Tukwila, WA 98188
Tenant Name: NTR METALS
Property Owners Name: Walton CWWA Tukwila 1 LLC c/o Walton RE TAX
Mailing Address: 4678 World Parkway Cir.
King Co Assessor's Tax No.: 2523049015
Suite Number: Floor: 1
New Tenant: ❑ Yes ❑..No
St. Louis
MO 63134
City
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: Katie Russell
Day Telephone: (206) 574 -4653
Mailing Address: c/o NTR Metals 814 Industry Dr. Tukwila WA 98188
City
E -Mail Address: krussell @ntrmetals.com
State
Zip
Fax Number:
MECHANICAL CONTRACTOR INFORMATION
Company Name: NTR Metals - Affidavit in Lieu Of Contractor Registration Filed
Mailing Address: 814 Industry Dr
Contact Person: Katie Russell
Tukwila
WA 98188
E -Mail Address: krussell@ntrmetals.com
Contractor Registration Number: n/a
City State Zip
Day Telephone: (206) 574 -4653
Fax Number:
Expiration Date:
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: NTR Metals
Mailing Address:
Contact Person:
E -Mail Address:
city
Day Telephone:
Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
NTR Metals
State
Zip
H:1Applications \Forms- Applicatioas On L nc\2009 Applicmions11-2009 - Mechanical Permit Application.doc
Revised: 1 -2009
bh
Page 1 of 2
•
Valuation of Project (contractor's bid price): $ 725
Scope of Work (please provide detailed information):
Install one 3'x3' exhaust hood and 12" duct work to and out roof.
Use: Residential: New ❑ Replacement ❑
Commercial: New ® Replacement ❑
Fuel Type: Electric ❑ Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000
BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000
BTU
Appliance Vent
Hood and Duct
1
Emergency Generator
50+ HP /1,750,000 BTU
Repair or addition to
Heat/Refrig/Cooling System
Incinerator — Domestic
Other Mechanical
Equipment
Air Handling Unit <10,000
CFM
Incinerator — Comm/Ind
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY WS OF THE ..: TE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER 1 ' AUTHORIZED AGE
Signature:
Print Name: Day Telephone:
Mailing Address: F121 J_ ��� S D/ Lt/i ( / 0. 4,/4- qn G
ri--
State Zip
Date: t.6 /6,/
y
•
Date Application Accepted:I
nko
Date Application Expires:
II �
r
Staff Initials:
/1
H:\ApplicationsTorms- Applications On Line t2009 Appl.cations\l -2009 - Mechanical Permit Application.doc
Revised: 1 -2009
bh
ATTACHMENT #1
SCOPE OF WORK FOR MECHANICAL PERMIT
NTR METALS
814 INDUSTRY DR.
TUKWILA, WA 98188
The following Mechanical work is proposed for the above listed address:
1) Install one MU1200 Melting Unit (CE Listed)
2) Install one 4' x 7' Type II Manufactured Heat / Fume Exhaust Hood above
Melting unit. with 12" ducting through roof. Duct pipe to extend min 3' from roof
surface and to covered with a conical cover. Duct to be fitted with 2280 cfm
110v fan at vent hood.
ano�uiEC°wau►
FEB 1J 2010
PERMIT CENTER
OP of Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: //www. ci. tukw ila. wa. us
SET RECEIPT
RECEIPT NO: R10 -00277
Initials: JEM
Payment Date: 02/17/2010
User ID: 1165 Total Payment: 401.89
Payee: WAYNE MCDONALD
SET ID: S000001349 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D10 -045
EL10 -0115
M10 -025
TOTAL:
150.03
79.80
172.06
150.03
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA - - - 401.89
TOTAL: 401.89
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
ELECTRICAL PERMIT - NONR
MECHANICAL - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.322.101.00.0
000.322.102.00.0
000.345.830
640.237.114
88.20
79.80
137.65
91.74
4.50
TOTAL: 401.89
PAYMENT
RECEIVED
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA -98188
INSPECTION RECORD
Retain a copy with permit
M -02S
PER��
(206)431 -3670
Project: r itteherif
Typ f Inspe do A
t
Add*sis:4 6 `/ i
4012_„Date
Called.
Special Instructions:
.
Date Wanted:
4-�3 -(0
a.m.
Requester:
Phone Nob /s 71 `1
653
Nri4, Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
Receipt
Af
REINSPECTION FEE ' QUIRE J3 Prior to inspection, fee must be
6300 Southcenter Blv. ., Suit 100. Call to schedule reinspection.
f-2,
o.:
Date:
te v...rloXhaftirth.k:(441110.1rattriagd.
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION =_
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
INSPECTION RECORD
Retain a copy with permit
A110 -02-5
FT NO.
Project.,�
Type ofAnspectioq: _ i midi
I ,
Address:
/-.4 ./Ad.uts-Plry .,oe
Date Called:
Special Instructions:
)/3' host -s Ifo
�J v
71n tZ ,� 0 J �
I OF- /.
G
%S� /0 pm/
Requester:
Phone No: to —In / ^"-lXid
{
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS: Xij44
0.'l ,ii � L&/
JAS
1 /I)61,h -' 4l
-r
4Y#VeL/
or:
Date:
/v
00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
at 6300 Southcen er Blvd., Suite 100. Call to schedule reinspection.
e1-€ipt No.:
Date:
AE
ENGINEERS, INC.
11155 120TH AVE. N.E.
SUITE 200
KIRKLAND, WA 98033
(425)739 -8051
April 13, 2010
Dave:
Katie Russell asked me to write you a letter concerning only wrapping their duct within 18
inches of combustibles. Since the installation does not strictly fall under the
circumstances that cover type 1 hood ie a grease hood I feel that some latitude can be
exercised in the requirements. In addition, the code states that the local code authority is
the ultimate authority on installations. With these facts in mind it is felt that having the
duct wrap only within 18 inches of combustibles would constitute a reasonably safe
instillation. Please call me at 206 - 498 -8261 (cell) or 425 - 739 -6051 (office) if you have any
questions.
Sincerely,
John Beebe, P.E.
Principal, AER Engineers
Cc: Chris Reed
RECEIVED
APR 212010
PERMIT CENTER
/L
PE
INDEX OF DRAWINGS
1 -1 COVER
1 -2 SITE
1 -3 MECHANICAL DETAIL
1-4 MECHANICAL FLOOR PLAN
1 -5 PROPOSED VENT LOCATION ROOF PLAN
PERMIT/PLAN PURPOSE
MECHANICAL PERMIT
Location Of Jobsite
z0/fit i6 ;4 l
DESCRIPTION
1
III' /' L
TO AID MELTING UNIT, HEAT/FUME EXHAUST
HOOD AND DUCT TO VENT OUT ROOF
Perm ft N�+.
OTT LC* E SET
to Dst i--as,
MO tk 3eNt 3 5asISe•m
NOS: 410kCeetitiff Rezix.re:
tt r ti a`s 6;tv
,iiynna• Come eroui Coq,'
'CC height:Micc "Introtoiat Cerro
4C Regicnt ^NnTeraa,
SCLI ReTiortal Cwrfrerclai Limed Joe
-JC Ta Ba ;Am Cep•►
at. Ccr.r•ewal.gb'Ina.14.0
ro'S licsv$a '4_741 Snot
L L4,1 (1114.74
i' ku'4 Altatt aI
►ACY
VoNlicoong Atikt Mal CevRePt r, *lama
A *i n+i Moneltr riti 1 ei esmoi Cor..er, Leavy t,dics7fal
Overlays and Sslb Arpaut
soioWava eta Cety 4rta
R.to: Heave arariey
St wens Overlay tArros natty 2X
ea s:actt►e•r.r:
1
REVIEWED FOR
CODECOMPLIANCE
APPROVED
APR 0 5 2010
CftyofTukwila
BUILDING DIVISInM
BUILDING 18 800 INDUSTRY DR
AREA OF WORK 14000 SQUARE FEET
INITR MET LS
814 INDUSTRY DR,
TUB ILA, lA 98166
PAGE 1 OF' 'ERMIT CENTER;
E VED
crr R0 TUKVIALA
FEB 1� .71;010
N3O 11WH1
NTR METALS
N CityGIS
i . 1
66 ft
Copyright 0 2006 All Rights Reserved. The information contained herein is the proprietary property of the
contributor supplied under license and may not be approved except as licensed by Digital Map Products.
,
0 02/16/2010
g
F-- 0
= I,. 20 rn331
' co
04: --r3 410 mic
z 0 , 19 0 Fn-
G) -.'"
c, 0*
0 Crn NA ik
=
n =
c:3
\k W'. . C(10cd
Pt- L,t(4 u (O 'tb A L
1) l- '1wok,t,
I REVIEWED Fp i
CODE COMPLIANCE
APPROVED
APR 0 5 2010
Rroi City of Tukwila
BUILDING D+ +S . ON
t'L A m . M610-L
1
4
c°
R '
x S
F4D01�
cAa f-t i /
c l(aoQ i
mti'l�[ t
istt1
90'
\11r'W`, fc o 1 ( 41 'M c4
c ocf We clkof
to*r
cnY oTuEKfm)IA
FEB 17MO
PERMIT CENTER
/ -'3
.\:\eCiAaOtCAL- UE NI- e +44k5 i 4-00C-1-11017
S14 INm95.104hL"DQ,,--twtw►i-N- ,wt giNtip
,4ca.(14, t14t`= 1` 02— die -2o�D
N'[tL 141r1A -lA I%RA, 3 a-5
w � c
cn
8' -2 33
0)
1/4" r 4' -4'
5.3 7:2 "x 4' -8'
FRONT OFFICE AREA
9' -4"
1'-11 1/8"-1 1, /r c,,°
0
0)
7' -6 1/4"
WAITING AREA
PROPOSED IMPROVEMENT - MECHANICAL FOR 814 INDUSTRY DRIVE, TUKWILA, WA 98118
70' -1"
BACK OFFICE AREA
11' -11 11/16"
►!m 2' -8_'I 6 5/81 2' -8 "•-■ 7'_9"
®
gyp! I (456 ' : E'.6 ,.6'n 4_n
' HALLWAY
1-
7 3/1,x+13' -8 5/8" - 4' -9 3/8" 11' -8 1/ " rn
enzerrommesumnam
r
2' 6' r 6'8' • 2'-4'
a
CO
N
BATHROOM c ?
4
70' -1 3/8"
7
2." puc.-v
PROPOSED EXHAUST VENT HOOD
4'X 7 WITH 12° PIPE OPENING & INUNE
2280 CFM FAN
66' -0 1/4"
WAREHOUSE AREA
12" VENT PIPING TO ROOF VENT
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 5 2010
City of Tukwila
BUILDING DIVIcinni
20' -0 13/16"
PROPOSED MECHANICAL IMPROVEMENT
814 INDUSTRY DR., TUKWILA, WA 98188
SCALE: 3/116 " = 1' 02 -16 -2010
/
PAGE ( OF
crtvoSu
FEB 17 2010
PERMIT CENTER
:
4
PROPOSED VENT LOCATION ROOF PLAN
FOR 814 INDUSTRY DR. - TUKWILA, WA 98188
70'-1"
FRONT OFFICE AREA
2/1 01-,t,-;,91-/C1 S-1
WAITING AREA
BACK OFFICE AREA
BATHROOM
V
HALLWAY
70' -1 3/8"
WAREHOUSE AREA
PROPOSED NEW ROOF VENT
FOR MELTING UNIT EXHAUST
NATURAL GAS WAREHOUSE HEAT
VENT
CODEIEWED FOR
COMPLIANCE
APPROVED
APR 0 5 2010
�
�
Tukwila
City BUILDING DIVI,4Iniv
-20'-0 13/16"
1
I
op
BATHROOM VENT
66' -0 1/4"
PROPOSED VENT LOCATION ROOF PLAN
814 INDUSTRY DR.,TUKWILA, WA 98188
SCALE: 3/16" = 1'
PAGE > OF
02 -16 -2010
cmoRCKEDwnLn
FEB 172010
PERMIT CENTER
IN UTHE
Erwiarmungsanlagen GmbH
P�'�ait No.
Instruction Manual for
Melting Machine
MU 400 to MU 1200
REVIEWED FOR
CODE COMPLIANCE
APR 0 5 2010
BUILD G of DIVI.SInm
INDUTHERM Erwarmungsanlagen GmbH
Brettener Strasse 32
D -75045 Walzbachtal
Germany
INCOMPLETE
LTR#
RECEIVED'
MAR 242010
PERMIT CENTER
Tel.: +49 7203 9218 -0
Fax: +49 7203 9218 -70
e -mail: info @indutherm.de
BEDIENUNGSANLEITUNG, MUt00_BIS MU1200_8X8XX GB.DOC 04.12 2009 KS
A
INDUTHERM
Contents
1. Introduction 3
1.1. General description of the MU melting machines 3
1.2. Machine components 3
1.3. Technical data 4
1.4. General information
5
2. Putting into operation 7
2.1. Set -up directions 7
2.2. Mains supply 7
2.3. Cooling water 7
2.4. RS232 connector
7
3. Operation 8
3.1. Operating elements 8
3.2. Casting 9
4. Service 10
4.1. Trouble shooting 10
4.2. Thermocouple connection / parameter setup 10
4.3. Maintenance 11
5. Connection diagram 12
6. Appendix 13
6.1. Spare parts list 13
6.2. Assembly drawing MU- series 14
6.3. Declaration of Conformity 16
6.4. System parameter and error codes 17
INDUTHERM
1. Introduction
1.1. General description of the MU melting machines
With this melting machine, the melting charge is heated up by induction.
The special advantage of inductive heating is that the melting temperature is reached rapidly,
because the heat is directly generated in the metal and in the crucible. During the melting
process, the metal is thoroughly mixed by means of a magnetic field, ensuring a homogenous
mixing even when using new alloys.
Installing the thermocouple in the crucible bottom allows an exact temperature measuring and
also the output of the unit is controlled in such a way that the set temperature remains
constant.
1.2. Machine components
The machine consists of separate units built into one casing:
1
Inside the casing, the following components are installed:
- mains supply and mains fuses (automatic cut -out)
microprocessor controlled induction generator
medium frequency transformer
- oscillation circuit capacities
2. The front panel consists of:
- operating panel for control of melting cycles
3. The casting unit consists of:
inductor, crucible, insulation parts, thermocouple
(�
1.3. Technical data
INDUTHERM
:
MU1200
Crucible volume
Crucible temperature
Melting performance
Cooling water recoil
Cooling water entry temperature
Room temperature
400 cm
6 k. /Au
700 cm
9 k. /Au
900 cm
�13k. /Au
max. 1500 °C with type S thermocouple
10 kW
3 *400 V /20 A, 50 or 60 Hz
3 * 208 V/32 A, 50 or 60 Hz o • tion
2.5 - 6 bar /at least 2001/h
without pressure
15 — 30 °C
10 — 35 °C
20 -80%
1200 cm
18k. /Au
500 mm * 500 mm * 900 mm
:�
INDUTHERM
1.4. General information
Safety information
In order to ensure a constant, ideal performance of the machine and to ensure safe working
conditions, the user is to observe the following safety measures:
• The complete electrical wiring is to be performed only by qualified and specially trained
personnel.
• Check the machine and the supply devices regularly on possible damages.
• When opening cabinet/casings or when removing parts (exception: when this is possible
by hand), certain parts under electric power can cause danger. If opening up the machine
is necessary (before maintenance, change of machine settings, repair or exchange of
parts) the machine must be cut off the mains voltage. If working on the opened machine is
inevitable, only qualified trained personnel aware of the danger caused hereby and aware
of the relevant regulations may be instructed to do this work.
• Capacitors in the machine can still be charged even when the machine's mains supply is
switched off.
• When it seems that the machine can no longer be worked safely it has to be taken out of
production and secured against further unintentional use. The following incidents indicate
that safe working is no longer possible:
- the machine is visibly damaged
- the machine does not function
- uncommonly heavy wear from transportation
• The safety valves placed inside the machine casing may not be removed, closed or altered
in any way.
• As melted metal is processed with this machine (= temperatures up to 1500 °C), the
utmost care and attention has to be applied when working with the Machine. The following
necessary safety clothing is principally to be worn:
- fireproof clothes
- fireproof closed shoes
- fireproof gloves
- safety goggles
• Special caution is essential when working with graphite crucibles and graphite dies
because these are only visibly hot at temperatures above 500 °C!
• In commercial enterprises the regulations for the prevention of accidents of the relevant
authority for electrical machinery are to be followed.
• People with pacemakers must not be near the machine while it is running.
INDUTHERM
• A trained responsible personnel is to supervise work with this machine.
Use as determined /liability
This casting machine is designed and manufactured to comply with the latest technical
knowledge and according to approved safety regulations. When not putting into operation
correctly or not using the machine as determined, however, danger and damages may occur.
Therefore we suggest reading carefully and completely this manual before putting the machine
into operation and to follow the instructions given therein:
• This machine is only to be used for melting, casting and granulating of precious metals
normally used for the production of jewellery.
• This machine may only be connected as mentioned in this manual. The mains supply as
well as in- and outgoing pressures are to be provided as stated on the machine label.
• This machine was designed for use in closed spaces (indoors) and may only be used for
the above - mentioned purpose.
• Only original INDUTHERM consumable and spare parts are to be used.
• The machine may not be modified in any way. Technical changes may only be effected
with INDUTHERM GmbH's prior written permission.
• Damages caused by disregard or false interpretation of the contents of this instruction
manual result in an immediate expiration of the machine guarantee.
• This instruction manual is conform to the latest technical condition of the machine when
printed. Technical changes and fittings subject to change.
• INDUTHERM GmbH cannot and will not take responsibility for any damages resulting of
the above mentioned.
• This instruction manual may not even partially be reproduced (photocopy, micro film,
computer processing etc.) without prior written permission of INDUTHERM GmbH.
2.3. Cooling water
Use two hoses with an inner o of 8 mm for the cooling water. The water entry pressure must
be at least 2.5 bar and must not be more than 6 bar. The water drainage must be without
pressure. The water entry temperature must be above 15 °C and must not exceed 30 °C. The
concentration of lime in the water must not be more than 60 mg CaO /I. The cooling water must
not be contaminated.
Caution: As long as the crucible temperature is above 100 °C, the cooling water supply must
be open; otherwise the inductor insulation could be destroyed. In case the cooling water
supply stops while there is still a hot crucible inside the machine, the crucible must be removed
once.
2.4. RS232 connector
At this connector our modem article no. 71000320 or the serial cable article no. 50500060 can
be connected
INDUTHERM
3. Operation
3.1. Operating elements
Temperature:
Normally, the actual crucible temperature is indicated here. When pressing the buttons
" +" or " —" the indication changes to the set -point value (nominal value) for at least 5
seconds. An active set -point value is indicated through an illuminated red decimal point.
The set -point value can be altered with the buttons " +" or " - ".
Water:
This signal Tamp illuminates when the water entry pressure is more than 2 bar. If the
water pressure is too low, the signal Tight extinguishes and the generator is stopped
after some seconds. The display shows error and there is an acoustic error signal.
Program:
It is possible to store up to 16 temperature values (1 -9 and A -F). To store a new value:
1. Select a program number (1 -9 and A -F) with the pushbuttons ' +' or ' -' (field Program).
2. Adjust the temperature value with the pushbuttons ' +' or ' -'
(field Crucible Temperature).
3. Press the pushbuttons ' +' and ' -' (field Program) simultaneously at least 1 second.
Now the new temperature value is stored.
Power:
-Button Start / Stop:
The generator is turned on /turned off with this buttons. The turned on generator
regulates principally to the adjusted nominal temperature (see Crucible - Temperature).
-Button + / -.
The maximum generator power is selected with this buttons
Other error codes: see appendix
4.2. Thermocouple connection / parameter setup
Type K / NiCr -Ni:
Green wire connected to X6, pin 1.
White wire connected to X6, pin 2.
Parameter: Al = 000, F6 = 114
Type S / PtRh -Pt: Orange wire connected to X6, pin 1.
White wire connected to X6, pin 2.
Parameter: Al = 001, F6 = 110
INDUTHERM
4.3. Maintenance
A routine check/regular cleaning of the following is necessary: (Caution: disconnect the
machine first!):
Daily (before casting):
1. Remove thermocouple, crucible and insulation materials, carefully clean inductor
housing with a vacuum cleaner. Before reinstalling the above parts, check those and
replace if necessary.
Annually:
Depending on the water quality, the cooling system should be cleaned with 25% citric acid.
The cooling system should be treated with this acid for approx. 1 hour. Then clean the system
thoroughly with pure water and check on eventual leakages.
1. Tighten all electric wirings, especially those for power current.
2. Tighten all connections of water - cooling.
1 I 2 1 3 1 4 5 I 6 I 7 I 8
A
B
C
0
E
-'
u
=6 =,
N N
c generator
E..se ye,era;or ■ith capaCttor (an
... O .rd 1SRT ror -rer hew k).-4.
c 68x0.68yF 400u
A
_
B
C
0
E
—
F
r c
or
7 , _ Dk �.0
3 ar' ,.o
1 8401
1.2 X1 X8
3 IRO:
_ _ _ _. _ _ __ _ __ __ _. __
relay board X101
3 _ _
X102 X9
5
13
X7
X6 4
5
X4
9
,3
X3
i5
or 2x32x0,68pF 480V
bk
Ll
L2
br
C -Batt.
1a>•
CEE32A L3 mom
N r= iT
bk
—
5 e x
-•-
transformer inductor
MU100'MU700 : 51588021 (USA: 51500011)
*e MU800if41200 • 61575010 (ws ercooled)
�- >- 1
�J
PE Cam—
J
9ry' -- —�.
1 it
operator panel
D t10 C
J
thermocouple \ _
water El--,/, _h . 2
Flasklift
lower position 2-4,___
[option)
Ua:sn.).a,.
"a "'`4:�
MU400 / MU700
MU900 / MU1200
INOUTHERM
Ar:.,,ere, Se•.1,
�r,.EaS wsi zt,acs d; wGS ^.'. �,er
Wireinq diagram
PeF rb
+
„ppr
I�„
1 ,I
_usl
Aiwee L-q
Oat..n
Nara
Nor �o
Ur spr. 1E, S.
£ra. 3.
1 [ 2 l 3 I 4 I
I 6 1 I 8
weJ6eip uoipauuo3 •9
Z
c
3
INDUTHERM
6. Appendix
6.1. Spare parts list
At following side the spare parts list for this machine will start.
INDUTHERM is now using only machine specific spare parts lists, which contain all the
information for your machine.
The list is printed on the following pages.
The name of the stored list starts with a
1.) G
2.) The next 5 digits are the machine number.
3.) Next is the specification for what application it is used for. (only at multipurpose
machines)
4.) The version index. A new machine has the index 00.
One example is G05120_VC_00. This is the list of the machine serial no 05120 and the spare
parts shown are for vacuum casting, index 00.
We are pleased to send you this data on request as a PDF file G05120_VC_00.pdf. This
makes it easy for you to order the correct spare parts. If the list changes and the index get one
step higher to 01 please save the old file 00 into a section "old" or delete it.
If spare parts are replaced by new parts, the index will be incremented. This ensures that you
always receive the latest version of consumables and spares. To be sure that the data is
correct, INDUTHERM and their sales partners or end customers must work together.
If the machine is used for several purposes like sintering and granulating, more than one list is
used for one machine like:
G05120_VC_00 All parts for vacuum casting
G05120_ CC _ 00 All parts for continuous casting
G05120_SI_00 All parts for sintering
G05120_GR_00 All parts for granulating
G05120_PA 00 All parts for steel and Palladium casting
For other spare or replacement parts please contact our sales partner for your country or our
order department at the telephone no.: +49- 7203 - 9218 -40.
INDUTHERM
6.2. Assembly drawing MU series
Cut INDUTHERM MU- Series
C083 as
one piece
glued
together
C063
C'058 I
C()()8
C067
C084
(glue)
C'102
C'081
C210
WftatiCkVIW Sittoe .Am .. - alt...
. ... mrprac
CO22
tc Xf, ;�- ddw .;� bY �r.,aWkr.tiCaSWn61:11Vhr`:.:,
C'211
..Fifas.�mu
Very important for correct temperature measurement:
Height X = mm is the thermocouple higher then the copper plate
xmm
MU400 and MU700 x =40mm, MU900 and MU1200 x = 50mm,
C'218
IErwarmungsanlagen GmbH
INDUTHERM
Erwarmungsanlagen GmbH
Brettener Stra(3e 32
75045 Walzbachtal
Germany
Telefon: +49/72 03/92 18 -0
Telefax: +49/72 03/92 18 -70
Order -list for spare parts
MU1200 serial no.:10030 customer 500NTR1
Order from:
your customer no.:
your customs no.:
your order no:
G10030_00
21 01.2010
Pos. ' Art. -No. ' Qty. , Unit i Description ' Picture
C083 10075906 '
pcs
graphite crucible + ceramic shell for
1 MU1200, graphite 0o= 116mm�
-•'`
0i =96mm, isolated for temperatures up
to 1400 °C, no hole, standard quality
Q =0101, quantity =l5kg,
C058 11175012
I pcs I crucible cover ceramic MU1200 with
new quality Q =8401,
C063 11175030 i
pcs isolation ring for MU1200
CO22 ;11275010 j
:pcs crucible bottom insulation MU1200 up';;
to 1300 °, h =25mm, 0= 150mm; °'s�
C082 10878010 ' pcs
thermocouple protection cover TM200 „4n,e ,k ,
i 1 graphite 2 n .,4
C051 i 12117010 pcs
sealing rod tube D15x282 GUNC3000
and for CC3000 granulating, ceramic
material Q =5000,
C070 13178010 , I pcs
I I
!
;thermocouple type K with connector for ' Ar''
1TM200. Up to temperature 1200° Iwo
C059 ; 14575010 i
, pcs crucible tongs MU1200
C165 86070010 pcs
' manual melting unit MU400_1200_GB
with spare parts
When you need larger quantities please ask for spezial offers.
Customer specific sizes for crucibles /dies are avaibable on demand.
INDUTHERM
6.3. Declaration of Conformity
Declaration of Conformity
Manufacturer:
INDUTHERM Erwarmungsanlagen GmbH
Brettener Strasse 32
75045 Walzbachtal- Wossingen
Germany
Tel.: +49- 7203 -92180
Fax.: +49- 7203 - 921870
Machinery
description: Melting Machines MU400, MU400V, MU400 VV,
M U700, MU700V, MU700VV, MU900, MU900V,
MU900VV,```hr' fi'i. MU1200V, MU1200VV
declares that the products herewith complies with the requirements
of the
98/37/EG (directive on machinery)
72/23/EWG (directive on low voltage)
changed in 93/68/EWG
89/336/EWG (directive on electro magnetic
compatibility)
changed in 2004/108/EG
Standards applied:
EN 61000 -6-4
EN 61000 -6 -2
and carry the CE marking accordingly
INDUTHERM Erwarmungsanlagen GmbH
Brettener Str. 32, — 75045 Walzbachtal- Wossingen, GERMANY
L
Peter Hofmann Dipl. -Ing. (FH) — Chairman
Walzbachtal, 23.06.2008
INDUTHERM
6.4. System parameter and error codes
At following side starts the current list of
System Parameters and Error Codes
Attention: On our webside
http://www.indutherm.de/errors.html
you can find examples how to troubleshoot errors
tat •
f . ,,.,- COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -025
PROJECT NAME: NTR METALS
SITE ADDRESS: 814 INDUSTRY DR
Original Plan Submittal
Response to Correction Letter #
DATE: 03 -24 -10
X Response to Incomplete Letter # 1
Revision # After Permit Issued
DEPARTMENT :
ul
(. 0
din Divisio j
Public Works
Fire Prevention
Structural
Planning Division
Fl
n Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete.
Incomplete ❑
DUE DATE: 03-25 -10
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 04 -22 -10
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
• PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -025 DATE: 02/17/10
PROJECT NAME: NTR METALS
SITE ADDRESS: 814 INDUSTRY DR
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
//D��.�E�PARTMENT :
&6itding `son 5.Q-ID
Public Works
FVw AVA-
ire Prevention
Structural
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete ❑
Comments:
Incomplete
DUE DATE: 02/18/10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg J/ Fire ❑ Ping ❑ PW ❑ Staff Initials: V(
TUES/THURS ROUTING:
Building
Please Route ❑ Structural Review Required
REVIEWER'S INITIALS:
n
No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03/18/10
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
Date: G
the mail,
fax,
etc.
Plan ChecWPermit Number:
Er Response to Incomplete Letter
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name:
Project Address: CC L ./ 1/'
Contact Person: lt� �- �55P,r' Phone Number: �Qf'p - 2`� - l/6 5
Summary o Revision: /
e U d!^a to 1//‘ e v- fn g. a /kit) 'Si %%a Awve° .S5 71 J S
�)^ e c v vh < Oci &tea' /� e ( be
� ryn �
a Is-, i ncllAded A_ 6 O 1 zts cc maw ua.1.
,A)Tg ,rxie.1/46
/Q -(iQS
RECEIVED
CiTYOFTUK�R
;MAR 2.4
PERMIT CENTER
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision 'l
Received at the City of Tukwila Permit Center by: 3 2- 1i 0 -1,A C)-J\
Igr Entered in Permits Plus on -23—.)-1A---1, 0
\applications \forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
AER
March 23, 2010
NTR Metals
814 Industry Drive
Tukwila, WA
Attn: Katie Russell
�a�s.Z
INC
IH AVE.. ME.
(42F)7.I
•
Dear Katie:
The following is Addendum #1 for the NTR Exhaust System:
THE CONTRACTOR SHALL INCORPORATE THE FOLLOWING ITEMS INTO THE CONTRACT
DOCUMENTS AS IF THEY HAD BEEN IN THE ORIGINAL DOCUMENTS
ADDENDUM #1
1. The hood fabricator has stated that the hood ( #18 steel) will weigh approximately 40 pounds.
The hood shall be supported with 4 each chains, each with a capacity of 100 pounds. The support shall
be installed in a manner to meet all seismic codes. The fire rated chase shall be supported independently
and shall not be supported by the hood chains. If the final weight of the hood is more than 40 pounds, the
capacity of the chains shall be increased proportionately.
2. A rain hood shall be furnished and installed on the roof exhaust fan.
Please call me at 206 -498 -8261 (cell) or 425 - 739 -6051 (office) if you have any questions.
Sincerely,
John Beebe, P.E.
Principal, AER Engineers
INCOMPLETE
Mao ,i&
RECEIVED
MAR 24 2010
PERMIT CENTER
•
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
February 18, 2010
Katie Russell
NTR Metals
814 Industry Dr
Tukwila, WA 98188
RE: Letter of Incomplete Application # 1
Mechanical Permit Application M10 -025
NTR Metals — 814 Industry Dr
Dear Ms. Russell,
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on
February 17, 2010 is determined to be incomplete. Before your application can continue the plan review
process the attached /following items from the following department(s) need(s) to be addressed:
Building Department: Allen Johannessen at 206 433 -7163 if you have any questions
concerning the attached comments.
Please address the comment above in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that two (2) sets of revised plans,
specifications and /or other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a "Revision Submittal Sheet" must accompany every
resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not
be accepted through the mail or by a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
Sincerely,
•RclAjtir_
Bill Rambo
Permit Technician
Enclosures
File: M10 -025
W: \Permit Center \Incomplete Letters \2010 \MI0 -025 Incomplete Ltr #1.DOC
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
Tukwila Building Division
Allen Johannessen, Plan Examiner
Determination of Completeness Memo
Date: February 18, 2010
Project Name: NTR Metals
Permit #: M10 -025
Plan Review: Allen Johannessen, Plans Examiner
The Building Division has deemed the subject permit application incomplete. To assist the applicant in
expediting the Department plan review process, please forward the following comments.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 1 1x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped,
not copied.)
1. Provide new drawings drawn to scale. Drawings shall be provided by a design professional, wet stamped
and signed by the design professional. Plans shall be complete with details identifying all materials and
method of seismically securing the duct. Indicate type of construction of the existing building. Floor plan
shall be complete with all dimensions identifying the size of unit and specific dimensions for location and
clearances of the mechanical equipment.
2. Provide manufactures specifications and UL listing for the melting unit, hood and duct.
3. Provide complete details for all penetrations through the roof.
Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670.
No further comments at this time.
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-3670 FAX (206) 431 -3665
E -mail: tukplant ci.tukwila.wa.us
Permit Center /Building Division
206 431 -3670
Public Works Department
206 433 -0179
Planning Division
206 431 -367o
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
STATE OF WASHINGTON)
) ss.
COUNTY OF KING )
` ► 1 / )4 , gvissQ_It , states as follows:
[please print name]
PERMIT NO: t-1 IJ'A,C WO —CO
CL o tc
1. -I have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requiremen of RCW 18.27.090,
I consider the work authorized under this permit to be exempt under number I', and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
to engage an unregistered contractor to perform constru
I understand that I may be waiving certain rights that I might 4, erwise - under state law in any decision
work.
0' ...a
i'41,1 I / /iii
6rf 00N E,r�'4 ��
AI lo, y
WS
4����OF\W P . ��
t
Signed and sworn to before me this
1 (.s2 day of k--.e Li--c , 2Oj .
NOTARY PUBLIC in and for the State of Washington
Residing at
County
Name as commissioned: , tASU- irccK
10-1q-,901(
My commission expires:
18.27.090 Exemptions, The registion provisions of this chapter do not apply t
1. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor,
10. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
by a registered contractor;
11. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12.* Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
13. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile /manufactured home dealer or manufacturer
who subcontracts the installation, set -up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set -up, or repair of the
mobile /manufactured homes that were manufactured or
sold by the mobile /manufactured home dealer or
manufacturer;
18. An entity who holds a valid electrical contractor's
license under chapter 19.28 RCW that employs a certified
journeyman electrician, a certified residential specialty
electrician, or an electrical trainee meeting the
requirements of chapter 19.28 RCW to perform plumbing
work that is incidentally, directly, and immediately
appropriate to the like -in -kind replacement of ahousehold
appliance or other small household utilization equipment
that requires limited electric power and limited waste
and /or water connections. An electrical trainee must be
supervised by a certified electrician while performing
plumbing work.
• Per Washington State Department of Labor and Industries, lessee has been
interpreted to be equivalent to owner for the purpose of these exemptions.
F
uc,50i.3 - -
Where mechanical exhaust is required in a
room or space, such space shall be
maintained with a neutral or negative
pressure. Adequate make up air consisting
of supply air, transfer an or outdoor air
shall be provided to satisfy the deficiency.
7/' rti-pr,1
12" HIGH ROOF CURB FLASH, CONSTRUCT, AND SEAL PER
LANDLORD'S REQUIREMENTS. RETAIN LANDLORDS ROOFING
CONTRACTOR IF REQUIRED BY LANDLORD.
30x12 OSA INTAKE
W/ BIRD SCREEN
AND BAROMETRIC
DAMPER
MIN 10'
WEATHER PROOF
FLEX CONN.
e- RAW ti-ooD NOT ..i\ONA/ t\1
11111111111111111111111111111111.111111111.111111111111111111111111111111111111111111111111111111111111111111111111111111111111
4
1-6"
30x12 MAKE—UP AIR DUCT
#18 MSG SHEET METAL
OVER GYP BD
WALL
120
VIBRATION ISOLATORS
COORD. W/ STRUCTURAL
FOR SUPPORT
ROOF
\ROOF JOIST
ROOF OPENING AND ROOFING. COORD. W/GC TO
HAVE LANDLORD'S CONTRACTORS PERFORM THIS
WORK AND TO INCLUDE THIS IN THE GC'S BID, IF
REQUIRED BY LANDLORD
NON—COMBUSTIBLE DUCT SHAFT.
SEE DETAIL B THIS SHEET.
EXHAUST HOOD 0.043" MIN STEEL (#18 GUAGE)
OR 0.037" MIN SS (#20 GUAGE)
30x14 MAKE—UP AIR OUTLET
7'-6"
1..
11-5—
2
2'-11-1..
2
FLOOR
14' 1"
MELTING EQUIPMENT 1 -6"
1
NOTES
1. CONTRACTOR SHALL INSTALL EXHAUST HOOD AND ALL
ACCESSORIES IN CONFORMANCE WITH LOCAL CODES AND SUBMIT SHOP
DRAWINGS TO LOCAL CODE AUTHORITY.
EX
AUST SYST
v
SECTIO
SCALE: 1/4"
#18 MSG SHEET METAL
OVER GYP BD
WALL
2HP FUSED DISC.
3 #12 CU W/GD
IN 1/2" EMT TO
POWER PANEL
30x12 OSA INTAKE W/ BIRD
SCREEN AND BAROMETRIC
DAMPER (ON ROOF)
l'-6"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 5 2010
Al-
QV of
BUILDING
1 '-6"
OF MELTING MACHINE-1
MELTING MACHINE 10"
EXHAUST HOOD
3 #12 CU W/GD
IN 1/2" EMT
2HP NON—FUSED DISC.
OF ROOF OPENING
NON—COMBUSTIBLE DUCT SHAFT.
SEE DETAIL B THIS SHEET.
6-8"
WEATHER PROOF FLEX CONN.
EXHAUST FAN
(ON ROOF)
EXHAUST SYSTEM
PLA\
SCALE: 1/4" = 1'-0"
ISION
FILE COPY
Permit No. 0,0 -2.2"-
Plan review approval is subject to errors and omissions.
Approved of construction documents does not authorize
the violation of any adopted codetook_uo nce. R: «Apt
d) 4 :i 1 ItY
of approved Field 1 ons is acknowledged:
0111&IL-K '
By . . . - -■ P ri 4341/14■
____ .44,‘ 4 t ____
Date:
City Of Tu Ila
BUILDING DIVISION
COPYRIGHT 2010, AER ENGINEERS, INC,.
.•
2 LAYERS OF
1/2" WALL BOARD
1—HR CAVITY SHAFT
WALL PER IBC.
6" MINIMUM
CLEAR ALL AROUND
EXHAUST DUCT
2x4 STUD
NOTE
CONSULT LOCAL CODES AUTHORITIES, INSTALLATION
MUST COMPLY WITH ALL LOCAL CODES.
FIRE RATED EXHAUST S-AFT CB)
SCALE: N.T.S.
M-1
•
ISEPARATT
REQUIRED FOR:
0 Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
EXHAUST FAN SCHEDULE
DESIGNATION
SERVES
MANUFACTURER
MODEL
CFM
RPM
SP
ELECTRICAL DATA
DRIVE
NOTES
HP
VOLTS/PHASE
EF-1
MELTING FURNACE
GREENHECK
SWB-210-20
2500
3350
1.0
2
208V./30
BELT
A, B
NOTES:
A. PROVIDE DISCONNECT SW (TCH (NEMA 3R).
B. TOP OF FAN SHALL BE ABOVE PARAPET. (FIELD VERIFY)
. REVISIONS
No chances shall be made to the scope
of Work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
INCOMPLETE
RECEIVED
MAR 24 2010
PERMIT CENTER
M1OO2 ,50
AER
ENGINEERS
11155 120TH AVE. N.E.
SUITE 200
KIRKLAND, WA 98033
(425) 739-6051
(425) 739-7362
AERI23@AOL. COM
A
DATE
DESCRIPTION
ISSUE DATE:
CHECKED:
DESIGNED:
DRAWN:
03-16-10
JOHN BEEBE
CHRIS REED
CHRIS REED