HomeMy WebLinkAboutPermit M10-028 - STARBUCKSSTARBUCKS COFFEE 333 STRANDER BL M10 -028 Parcel No.: 2623049064 Address: Suite No: Citylif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 333 STRANDER BL TUKW MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M10 -028 03/05/2010 09/01/2010 Tenant: Name: STARBUCKS COFFEE Address: 333 STRANDER BL , TUKWILA WA Owner: Name: REGENCY CENTERS LP Address: C/0 PROPERTY TAX DEPT , PO BOX 790830 Contact Person: Name: GETINET ALEWAB Address: 8816 152 AV NE , REDMOND WA Contractor: Name: T E C MECHANICAL SERVICE CO. Address: P.O. BOX 3550 , REDMOND, WA Contractor License No: TECMESC 143BA Phone: Phone: 425 881 -3247 Phone: 206 881 -3247 Expiration Date: 02/01/2011 DESCRIPTION OF WORK: REMOVE AND REPLACE 4 -TON PACKAGE ROOF TOP AIR CONDITIONING UNIT LIKE FOR LIKE ON EXISTING CURB AND PENETRATION. Value of Mechanical: $6,058.00 Type of Fire Protection: Fees Collected: $264.81 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment1 * *continued on next page ** doc: IMC -10/06 M10 -028 Printed: 03 -05 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M10 -028 Issue Date: 03/05/2010 Permit Expires On: 09/01/2010 Permit Center Authorized Signature. AAA, ktek Date: 3 -` I U I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I arg authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: 03/0 5 /Zc%D This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M10 -028 Printed: 03 -05 -2010 Parcel No.: 2623049064 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 333 STRANDER BL TUKW STARBUCKS COFFEE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10-028 ISSUED 02/26/2010 03/05/2010 1: ** *BUILDING DEPARTMENT CONDTITONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 10: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits doc: Cond -10/06 M10 -028 Printed: 03 -05 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10 -028 Printed: 03 -05 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Ditk lAek. Ak-4 Date: 03/0 5/2-° 10 ordinances governing or local laws regulating doc: Cond -10/06 M10 -028 Printed: 03 -05 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Permit No, /J\, t Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Site Address: 333 Strander Blvd, Tukwila WA 98188 Tenant Name: Starbucks Coffee Property Owners Name: REGENCY CENTERS L P Mailing Address: C/0 PROPERTY TAX DEPT PO BOX 790830 Suite Number: 2-62.3049a64- New Tenant: Floor: ❑ Yes ®.. No SAN ANTONIO TX 78279 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Getinet Alewab Day Telephone: (425) 881 -3247 Mailing Address: 8816 152nd AVE NE Redmond WA 98052 City Fax Number: E -Mail Address: galewab @tecmechanical.com State (425) 882 -0226 Zip MECHANICAL CONTRACTOR INFORMATION' Company Name: Mailing Address: 8816 152nd AVE NE Redmond WA 98188 City State Zip Day Telephone: (425) 881 -3247 E -Mail Address: galewab @tecmechanical.com Fax Number: (425) 882 -0226 Expiration Date: 02/01/2011 TEC Mechanical Contact Person: Getinet Alewab Contractor Registration Number: TECMESC143BA ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: N/A Mailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State ENGINEER OF RECORD _All plans must be wet stamped by Enginee of Record Company Name: N/A Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip hi:\Applications\Forms- Applications On Line \2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 1 of 2 • • Valuation of Project (contractor's bid price): $ 6,058 Scope of Work (please provide detailed information): Remove and replace a 4 ton package roof top air conditioning unit like for like on existing curb and penetration. Use: Residential: New Commercial: New Fuel Type: Electric ❑ Replacement Replacement Gas ® Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment 1 Air Handling Unit <10,000 CFM Incinerator — Comm /Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGE Signature: Print Name: Getinet Alewab c T: Mailing Address: 8816 152nd Ave NE Day Telephone: Redmond Date: 0 21 2-5 /2010 (425) 881 -3247 WA 98052 Date Application Accepted: City State Zip Al 1(0 Date Application Expires: 0/ 1741,0 Staff Initials: H:Wpplications \Forms - Applications On Line \2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 333 STRANDER BL TUKW Suite No: Applicant: STARBUCKS COFFEE RECEIPT Permit Number: M10 -028 Status: PENDING Applied Date: 02/26/2010 Issue Date: Receipt No.: R10 -00347 Payment Amount: $264.81 Initials: JEM Payment Date: 02/26/2010 04:13 PM User ID: 1165 Balance: $0.00 Payee: GETINET B ALEWAB TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 161300 ACCOUNT ITEM LIST: Description 264.81 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 211.85 000.345.830 52.96 Total: $264.81 PAYMENT RECEIVED doc: Receiot -06 Printed: 02 -26 -2010 ,62.8 • 6. r• st- INSPECTION RECORD e a ,copy with permit ECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 11 Type of Inspectio du A resd"d s 3 ,Ittiel •Sp del to Called: • cia Instructions: • Date Wanted: 0 /chi -_J n. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. r. ENTS: - 443 p! d1/es (44.- R • NS' ION EE ' EQUI 'r U. Prior to n - xt inspection. fee. must be 300 Southcenter Blv .. Suite 100. all to schedule reinspection. w. w. •• •v: ■ 1.4.9.41 INSPECTION NO. INSPECTION RECORD Retain a copy with permit /il/o -o2 j PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670'N. Project: ��74,j7/(1 5 ('Fr/F Type of Inspection: t- • rv6. C Aclesm: 3 57vItii.v 2 Date Called: Special Instructions: / 04/7 rJtiP. /Cf 0 2/& -0/ _ Date Wanted: •%-2,j- /O p.m. Requester: Phone No: a06-5/ a -5860 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: jnsp ce� pr: 60.00 REINSPECTION F E REQUIRED Prior to inspection, fee must be aid at 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. 7- 23- _ l G, 2 Receipt No.: Date: GAS HEATING ELECTRIC COOLING UNIT SCHEDULE NUMBER AREA SERVED MAKE MODEL SUPPLY FAN COOLING COIL HEAT EXCHANGER ELECTRICAL MISCELLANEOUS DATA CFM MIN. OA EXTERNAL S.P. (IN. W.G.) RPM BHP SEER EER EDB EWB SENS. MBH TOTAL MBH TOTAL CFM EDB MBH INPUT MBH OUTPUT AFUE ( %) VOLTS /PH /HZ MCA MOCP SOUND IdB) WEIGHT REMARKS GP -1 STORE CARRIER 48TCDA05A2A5 1600 320 0.65 825 0.42 13.0 11.0 78.8 65.4 31.95 43.83 1600 60.0 72.0 59.0 82 208 - 230/3/60 23.5 30.0 81.0 537 t2 1. EXISTING UNIT WEIGHT IS 548 LBS. 2. PROVIDE W/ MANUFACTURER FURNISHED 0% TO 100% ECONOMIZER. SCOPE STATEMENT REMOVE AND REPLACE A 4 -TON GAS /ELECTRIC ROOFTOP UNIT IN KIND WITH 0% TO 100% ECONOMIZER. FILE COPY Permit No. la" 0. Plan review approval is subject to MOM and ondsslons. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field • I And - utp. -I, ,: - Is acknowledged: By Date: O 3 /or; / 201 a City Of Tukwila BUI iSp SION E:3C7 GP -1 ON ROOF PROPERTY LINE `♦ PARCEL &: 2623049064 1 — r ZI VICINITY /SITE MAP SCALE: 3/32' = 32' -0' ANDOVER PARK W NOTE(S): PROPERTY /BUILDING LINES AND DIMENSIONS ARE TAKEN FROM KING COUNTY IMAP SATELLITE PHOTO DATA & FIELD MEASUREMENTS. SEPARATE PERMIT REQUIRED FOR 0 • Plumbing • Gas Pipbg City of Tukwila '1 -DING DIVISION LEGAL DESCRIPTION /PARCEL NUMBER LEGAL DESCRIPTION: LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 91 -9 -SS RECORDING NO 9208261819 SAID SHORT PLAT DAF - POR OF SW 1/4 OF NE 1/4 - BEG SW COR OF NE 1/4 TH N 01 -10 -24 E 1293.57 FT TO S MGN OF STRANDER BLVD TH 5 88 -15 -33 E 665 FT TO POB TH S 01 -44 -27 W 63 FT TAP OF TANGENT CURVE CONCAVE TO NE RAD OF 130 FT TH SELY ALG SD CURVE THRU ARC OF 34 -27 -01 ARC LENGTH OF 78.17 FT TH 5 88 -15 -33 E 212.17 FT TH S 01 -44 -27 W 62 FT TH 5 88 -15 -33 E 9 FT TH S 01 -44 -27 W 62 FT TH N 88 -15 -33 W 133 FT TH S 01 -44 -27 W 150 FT TH N 88 -15 -33 W 482.33 FT TH 5 48 -28 -37 W 113.91 FT TH S 01 -44 -27 W 37.10 FT TH N 88 -15 -33 W 120 FT TH S 01 -44 -27 W 80 FT TH N 88 -15 -33 W 84.69 FT TO W LN OF SAID SW 1/4 TH S 01 -10 -24 W 687.83 FT TO SW CORNER OF NE 1/4 TH S 88 -06 -43 E 1309.38 FT TO W MGN OF ANDOVER PARK WEST TH N 01 -03 -25 E 1296.97 FT TO 5 MGN OF STRANDER BLVD TH N 86 -15 -33 W 641.71 FT TO POB - -- AKA LOT 2 OF CITY OF TUKWILA LOT LN AD1 NO 88 -6 -BLA RECORDING NO 8901240241 - -- LESS PORTION FOR R/W TO CITY OF TUKWILA PARCEL NUMBER: 2623049064 ADDRESS: 333 STRANDER BLVD, TUKWILA WA 98188 ROOF REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division, NOTE: Revisions will require a new plan submittal and may include additional plan review fees. GP -1 ON ROOF RECONNECT (E) N.G. TO NEW UNIT co U co cu U 0 w (` 0 00 O) 0 CC Ph: 425 - 881 -3247 / Fax: 425 - 882 -0226 SHEET TITLE: SCHEDULE, NOTES SITE MAP, SCOPE STATEMENT & LEGAL DESCRIPTION AND HVAC ROOF PLAN REVIEWED FOR CODE COMPLIANCE APPROVED AAR 0 2 2010 41-City of Tukwila -MIMING DIVISION HVAC ROOF PLAN SCALD r -,a NOM -NEV UOT IOLD CIOSTOC. CURS . POETRATDI awe rev PROS) -REDSoECT m D.ECTRK*L TO IEV I*OT -WOVE CDOEMATE DIVA TO THE WARIEST ROO, SRAM - RECENCCT E7OSTOIO OAS LOE TO CV OUT RErD CITY FEB 2 6 2010 PERMIT CENTER > o0 C4.) h CO rg 4t wv • Z a 4 co) k t~ co) INITIALS DRAFTED: GBA DESIGNED: GBA CHECKED: GBA REVISION TITLE DATE 02/26/10 M1()-()Vfb M1/1 • Physical data d 33 / BASE UNIT 48 SERIES DJE004 DJE /DJD005 DJE /DJD006 DJE /DJD007 NOMINAL CAPACITY (tons) 3 4 5 6 OPERATING WEIGHT (lb) Unit 530 540 560 615 *With Economizer 1548) 558 578 633 Roof Curb 115 115 115 115 COMPRESSOR Hermetic Manufacturer Carlyle - J37 Carlyle - J48 Copeland - CRP5 Carlyle - W72 Quantity...Type 1 1 1 1 011 (oz) 46 46 70 64 REFRIGERANT R -22 Operating Charge (lb -oz) 4 -3 5 -4 1 6 -11 9-0 CONDENSER FAN Propeller Quantity...Diameter (In.) 1...26 1...26 1.. 26 1.26 Nominal Cfm 3500 4100 4100 3800 Motor Hp...Rpm 1/2...850 1/2...850 2...850 '2...850 CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fin Rows...Fins/in. 1.. 17 1 . 17 1.. 17 2 17 Total Face Area (sq ft) 7.78 12.25 1 12.25 12.25 EVAPORATOR FAN Centrifugal Size (In) 10x10 10x10 10x10 10x10 Type Dnve Direct Direct /Belt Direct /Belt Belt Nominal Cfm 1200 1600 2000 2400 Motor Hp Std 'A h Y4 Y4 Alt 1/2 1.0 1 0 1 0 Motor Frame Std 48 48 48 56 Alt 48 56 56 56 Nominal Rpm Hlgh /low Std 860/845 1080/ 970 1080/1040 1670/1570 Low 1080/970 1670/1570 1670/1570 — Fan Rpm Range Std 860/845 1080/ 970 1080/1040 1110/ 870 Alt 1080/970 1110/ 870 1110/ 870 — Maximum Fan Rpm Std 2100 2100 2100 2100 Alt — 1800 1800 1800 Motor Pulley Pitch Diameter Std — — — 28/3 8 A/B (in.) Alt — 2.8/3.8 2.8/3.8 28/3 8 Fan Pulley Pitch Diameter (in.) Std — — — 5.2 Alt — 5.2 5 2 5.2 Belt — Type_.Length (In.) — A...42 A...42 A...42 EVAPORATOR COIL Enhanced Copper Tubes, Aluminum Double Wavy Fin Rows...Flns/ln. 2. 15 2..15 3.. 15 4...15 Total Face Area (sq ft) 4.17 5.5 5.5 5.5 FURNACE SECTION Burner Orifice Diameter (In. ...drill size) Natural Gas — Std .116.. 32 116 32 116 .32 116 .32 Liquid Propane — Alt 089. 43 089 .43 089 .43 089 ..43 Thermostat\Heat Anticipator Setting (amps) 208/230/480 v 1.0 1 0 1 0 1 0 Gas Input 74,000 74,000/115,000 74,000/115,000 74,000/115,000 Efficiency (AGA Steady State) (" /o) 79 79 79 79 Temperature Rise Range 25 -55 25- 55/35 -65 25- 55/35 -65 25- 55/35 -65 HIGH - PRESSURE 'SWITCH (psig) Cutout 428 428 428 428 Reset 320 320 320 320 LOW-PRESSURE S ITCH (pslg) _ Cutout 27 ± 4 27 ± 4 27 ± 4 27 ± 4 Reset 67 ±7 67 ±7 67 ±7 67- '-7 OUTSIDE AIR INLET SCREENS Quantity...Size (In.) 1...20 x 24 x 1 RETURN AIR FILTERS Quantity...Size (in.) 2 ..16 x 25 x 2 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 2 2010 City of Tukwila BUILDING DIVISION FILE COPY Permit No. &Y.?. of r 3 E IVED CITRY OFTUKW A FEB 2 6 2010 PE,- T .{d 1 a-/r7/ y @ 054 CURBS & WEIGHTS DIMENSIONS - CHASSIS 1 (cont.) UNIT STD. UNIT WEIGHT CORNER WEIGHT 141 CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT ID) SUPPLY AIR OPENING I C.G. Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non - conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 -ft of unit fresh air intake hood HEIGHT LOS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. 0 Y Z 48TC -A04 483 219 111 50 125 57 131 59 116 53 39 [991] 23 [5841 16 3/8 [416] 48TC-A05 537 244 124 56 139 63 145 66 129 59 39 [991] 23 [584] 17 (4321 48TC -A06 569 258 131 59 147 67 154 70 137 62 39 [991] 23 [5841 17 1/4 [438] 48TC -A01 652 296 150 68 169 76 176 _ 80 157 71 39 [991] 23 [584] 20 1/8 [5117 CORNER A TOP 0' -3" 0761 0' -3. C761 1' -1 7/16' C341] 4d 0' -0 7/16' C11] (BOLT HEADS) 0'-0 7'16' C11] (BOLT HEADS) I' -7 13/16' CSO4] 0' -3' C76] 3 " -0' C914] 1,8' ._1'1 C334] Fig. 3 - Curb Dimensions CORNER 8 E 0o (=l. : oo CORNER C Fig. 2 - Dimensions 48TC 04 -07 2' -7 Si8" C8031 , 0'-0 7;'16 C11] (BOLT HEADS) 0'-0 7/16' (111 (BOLT HEADS) C07458 FRONT GASKET ......(SUPPUED WITH CURB) NAIL COUNTER ASHINO 0-TELL/SUPPLIED) - ROOFING FELT ! (FIELD SUPPLED) CANT STRIP FIELD SUPPLIED) �\ ROOFING FELT (FELL/SUPPLIED) Fig. 4 - Curb Installation Detail (Typical) 1 J C08593 C07457 Fig. 5 - Service Clearance C08337 LOC /. \ \ • / \ .1 ' \�"1—\ - -mot I 1 II \ / / / \r / / CONDITION A RETURN AIR e OPENING Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance SUPPLY AIR OPENING I 42" (1067 mm) 36" (914 mm) Special I' -7 13/16' CSO4] 0' -3' C76] 3 " -0' C914] 1,8' ._1'1 C334] Fig. 3 - Curb Dimensions CORNER 8 E 0o (=l. : oo CORNER C Fig. 2 - Dimensions 48TC 04 -07 2' -7 Si8" C8031 , 0'-0 7;'16 C11] (BOLT HEADS) 0'-0 7/16' (111 (BOLT HEADS) C07458 FRONT GASKET ......(SUPPUED WITH CURB) NAIL COUNTER ASHINO 0-TELL/SUPPLIED) - ROOFING FELT ! (FIELD SUPPLED) CANT STRIP FIELD SUPPLIED) �\ ROOFING FELT (FELL/SUPPLIED) Fig. 4 - Curb Installation Detail (Typical) 1 J C08593 C07457 Fig. 5 - Service Clearance C08337 LOC DIMENSION CONDITION A 48" (1219 mm) 18" (457 mm) 18" (457 mm) 12" (305 mm) Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance B 42" (1067 mm) 36" (914 mm) Special Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non - conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 -ft of unit fresh air intake hood C 36" (914 mm) 18" (457 mm) Side condensate drain is used Minimum clearance 0 48" (1219 mm) 42" (1067 mm) 36" (914 mm) Special No flue discharge accessory installed, surface is combustible material Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non - conductive (e.g., wood, fiberglass) Check for adjacent units or building fresh air intakes within 10 -ft of this unit's flue outlet 17 Options and Accessories ITEM OPTION' ACCESSORY X X X X X X X X X X X X X X X Economizer Manual Outside Alr Damper Two - Position Damper Alternate Drive Root Curb Thru- the -Curb Service Connections Flue Shield Low Ambient Kit Thermostat and Subbase T7300 Thermostat Time Guard Motormastere Solid State Enthalpy Control Differential Enthalpy Sensor LP Conversion Kit Hail Guard t 'Factory installed tField installed Base unit dimensions UNIT STD UNIT WEIGHT LBS. KG. 48DJE004 530 240 48DJE /0J000S 540 245 460JE /0J0006 560 254 480J6 /0J0007 615 279 ECONOMIZER WEIGHT LBS. KG. 18 8.2 CORNER WEIGHT (A7 LBS. G. 104 47.2 106 48.1 110 49.9 120 54.4 CORNER WEIGHT (80 L05. KG. CORNER LBS. IGHT (C) KG. CORNER WEIGHT (01 97 44.0 159 72 98 44.5 162 73.5 L85. 171 174 KG. 77.6 78.9 102 46.3 168 76.2 le0 01.6 112 NOTES. 1 01NEN91085 IN ( I ARE IN MILLINEIEA5 2 0 CENTER OF GRAFT . 3 127. 01RECTION CO AIR 0.011 4 00(1 00 TO BE ATTACHED TO ACCE550RY ROOF CURB My 5 5EO0ICE CLEARANCE A ON ALL FIFE SIDES 6. REFER TO PRINT FOR ROOF CURB ACCESSORY DIRER510N5 CONNECTION 51055 A 1 3/8' DIA. (35) FIELD RIVER 5UPPL1 MOLE 2" 01A. 150.51 FOVER SUPPLY KNOC4 -OUT C 2 3/16' DIA. (551 CHARGING PORT MOLE 0 7/0' DIA. '221 FIELD CONTROL FIRING HOLE 3/4' -)4 NP' CONDENSATE DRAIN 1/2' -14 NPT OAS CONNEC)10N CORNER 'A' 50.8 . 185 83.9 19E OUTSIDE AIR REAR Vo FILTER/ECONOMIZER ACCESS PANE_ =FNMA COIL LEFT SIDE 3 -9' 11140 t0 -7 3/8 51871 It (432 07 16331 ECONOMIZER 8000 2 -I 115' 1652] EVAPORAT00 COIL RETURN AIR OPENING 0/5 I L • 0 -2 15/16"+ (751 0 -4 I/2 010 ALT. CONDENSATE 2RAIN 0PENIN6 N 8A5EPAN CORNER 'Cr 0 -3 13/16' 1971 FLUE NDOD 2 -8 1/2' 18261 I -45/15" (415) 0 -3 3/4' (951 -5 3/18' 4511 TYP 5 51 LEFT SIDE (127) -4 9/16' 1725 51+ FRONT 0' -3 1 /16' -1 (1/16' E781 (16721 I -57/16' 5041801 600/ 1442 51 COIRNES50R/ 1 WAWA ACCESS 0 -4ve'S 11057 69.8 -E- FT. IN. 3 " -1 134' 1' -2 1/4' (' -2 1/4' (' -2 1/4' 101 947 362 362 362 1 -4 3/0' 14161 0 -J 3/161 /CORNER '8' (9)1 \/ D•-5 7/18' ((361 0 - 10x15/16' YelZa RETURN AIR (2)01 EI RIGHT SIDE SUPPLY AIRI 09E1060 I 0/5 -0 1 /1E., 13081 INDOOR FAN MOTOR t 010800 ACCESS PANEL g _J34 2 `' 3/1 p53j 4' FORK TRUCK SLOTS /0 -4 15/16' 1 (1251 (1471 1 3/6'(357 SUPPL1 AIR RETUR4 AIR FRONT (119 6 PLACES) RIGHT SIDE STD. CONDENSATE DRAIN 1 1_0 -2 1657 1 (6)) -5 3/4" lA> SUPPLY AIR f� l 0' -5 7/16' (1181 0 -3 3I15'-'4--CORNER -C' F(91) -5 1/ e -0 3/6' (444) 1101 0 -7 1/2' 1190 5) '- 0 5/ ' 0 -4 I/4' 12701 1108) FILTER ACCESS DOOR (0(5P058811 FILTERS) 2 -1 1/2' (640) ACCESSORY 1000 FILTER OUTSIDE AIR 2 -2 1/4' 0 -4 11/16' 16811 11191 3/4' (5021 4 Accessory dimensions ROOF CURB DIMENSIONS ROOFCURO ACCESSORY S004900771 A I- -2' [3561 UNIT SIZE 48011) 007 NOTES, 1 MOACLRB ACCESSORY (SEE CHART/ IS SNIPPED O(OASSH(BLEO. 2 INSULATED PANELS. 1' TIK, POLYUREINANE 60611 1 -3/4 • 0(N5110 3 030TC07ON9 IN (1 ARE IN MILLIMETERS 4 R00'7!'t'1888,,C(608 (66'03- "1((((7C1Up311 7. DIS(IECTI WAIN FLT 510E UNIT SIZE 400J0004 400J0Z LF09fr0Q7 'E "OAS l€ 'F "POWER 3/1'(101 9/1'[18] SERVIC PLATE SIZES '0'CONTROL CONNECTOR PK0 ACT. 3/4'(191 500)900701 ! /VIEW 0 -3' 1761 0731 1 -1 3/16- (360) - f %, C;-.. -_1 1 / LI 1, ll ' Y 1 \L/ / '''--1' -5 31 ' [541 OPE�NG IA 1'-4 I/0'1 T 1 SDPPLY AIR OPENING 0 -0 I/4' 171 0 3.3/4' 1951 UNIT O89(ET (SUPPLIED PITN CUM 0 /NB. IL (F(ELO SUPPLIETO 01019 INSULATION 6IEL0 9PPLIECO COUNIFA FLA91(80 (FIELD APPLIED) R00FINU FELT v1EL0 SUPP.IE0( CART STRIP (FIELD 1PPLIED) ROOFIN6 NATERI AL (FIELD SUPPLIED) SEE NOTE 42 TYPICAL (4) SIDES ( SERVICE PLA1E 1 -4 13/16' (4271 -6 I/4' ((5OL 1 3/4'(44 S) ALT CRAIN NO4.6 • • • F' f16E •0• 0 -7 1/113' E (1 (1801` PLANE 2 -0 3/16 (0(01 (EAD OF BOLT 10 BE ON 11610E OF FLANGE 0 -I 1/4' I 1 7/10' 6041 [9411 0 -3' ! (761 0' -0 7/16' (113 T 19/1 J 3'-0 /1' 0'-0 7/16' L1 192 1 (111 (DOLT MEADS) 5 -7 3/8 (17111 (BOL1 NEA05) A +A -O- MR ALL CORN(00) //TO -3 3' -1 3/16' 19441 SEE VIEW -O"./ Selection procedure (with 48DJE005 example) Determine cooling and heating requirements at design conditions. Given: Required Cooling Capacity (TC) 47,000 Btuh Sensible Heat Capacity (SHC) 32,000 Btuh Required Heating Capacity 85,000 Btuh Condenser Entering Air Temperature 95 F Evaporator Entering Air Temperature 80 F edb, 67 F ewb Evaporator Air Quantity 1600 cfm External Static Pressure (ESP) 35 in. wg Electrical Characteristics (V- Ph -Hz) 230 -1 -60 I1 Select unit based on required cooling capacity. Enter Cooling Capacities table at condenser entering temperature of 95 F, evaporator air entering at 1600 cfm and 80 F db and 67 F wb. The 48DJE005 unit will provide a total cooling capacity of 50,800 Btuh and a sensible heat capacity of 35,600 Btuh. For evaporator air temperature other than 80 F edb, calculate sensible heat capacity correction, as required, using the formula found in the notes following the Cooling Capacities table. NOTE: Unit ratings are gross capacities and do not include the effect of indoor fan motor heat. To calculate net capacities, see Step V. III Select heating capacity of unit to provide design condition requirements. In the Heating Capacities table note that unit 48DJE005 will provide output capacity of 90,850 Btuh, which is adequate for the given application. 5 IV Determine fan speed and power requirements at design conditions. Job requirements call for .35 in wg ESP The additional pressure drop of the economizer must be added. Job ESP + economizer pressure drop = Total ESP .35 + .05 = .40 ESP Enter the Fan Performance curves for 48DJE005 down - shot at 1600 cfm and note that at high speed (230 v) the ESP of the fan is .50 in. wg and 500 Watts. Enter the Accessory /FIOP Pressure Drop table and note that the filter pressure drop is .08. 50 - .08 = .42 in. wg This will adequately handle the job requirements. V Determine net cooling capacity. Cooling capacities are gross capacities and do not include indoor fan motor (IFM) heat Determine net capacity using the following formula: Net capacity = gross capacity - 1FM heat Btuh = 50,800 Btuh - 500 Watts (3.413 ) Watts = 50,800 Btuh - 1707 Btuh Net capacity = 49,093 Btuh Net sensible capacity = 35,600 Btuh - 1707 Btuh - Net sensible capacity = 33,893 Btuh Performance data HEATING CAPACITIES AND EFFICIENCIES UNIT MODEL 48 SERIES HEATING INPUT (Btuh) OUTPUT CAPACITY (Btuh) TEMPERATURE RISE F () AFUE o ( /0) AGA STEADY STATE EFFICIENCY ( %) CALIFORNIA SEASONAL EFFICIENCY (%). DJE004 74,000 58,460 40 75 7 79 73 3 tDJD005 t74,000 n58,4604 40 ,t. 75 7 e7.9 73 3 DJE005 115,000 90,850 50 75 7 79 74.1 DJD006 74,000 58,460 40 75.5 79 73.3 DJE006 115,000 90,850 50 75.7 79 74.1 DJD007 74.000 58.460 40 75.7 79 73 3 DJE007 115,000 90,850 50 75.7 79 741 AFUE - Annual Fuel Utilization Efficiency NOx Levels - 40 nanograms /joule with accessory kit ARI CAPACITIES UNIT MODEL 48 SERIES NOMINAL TONS STANDARD CFM NET COOLING CAPACITY Btuh (Btuh) TOTAL kW EER SEER BELS IPLV With Timer Without Timer DJE004 3 1200 35,000 4 167 36 5 4 9 5 9 3 8 3 9 8 1DJ0005 , 4 1600 49,000 5 765 r 5 9.5 9.3 8 3 9 9 DJE005 4 1600 49,000 5 765 3.15 5 9.5 9 3 8.3 9.9 DJD006 5 2000 60,000 7 059 34.7 5 9 5 9 3 8 3 9 9 DJE006 5 2000 60,000 7 059 23.4 5 9 5 9 3 8 3 9 9 DJD007 6 2400 71,000 8 256 3.40 6 - - 8 3 9.6 DJE007 6 2400 71,000 8 256 32 9 6 - - 8 3 9 6 Rated in accordance with ARI Standards 210 -81 and 270 -82. Ratings are net values, reflecting the effects of circulating fan heat Ratings are based on Cooling Standard: 80 F db, 67 F wb indoor entering air temperature and 95 F db air entering outdoor unit COOLING CAPACITIES 48DJ004 (3 -TON) Temp (F) Air Ent Cond (Edb) Evap Alr - Cfm /BF 900/.156 1200/.193 1 1500/.224 Evap Air - Ewb (F) 72 67 62 72 67 82 72 67 62 TC 40.0 36 5 32.9 41 7 38 3 35 2 42 9 39 6 36 5 85 SHC 19.6 24.1 28.2 21.5 27.3 32 4 23.0 30 0 35 7 kW 3.27 3.15 3.03 3.32 3.21 3.11 3.36 3.25 3.16 TC 38.0 34.7 30 9 39 7 36.4 33.3 40 7 37 6 34 6 95 SHC 18.9 23.4 27.1 20.8 26.5 315 22.4 29.4 34.6 kW 3.52 3.40 3.27 3.59 3.46 3.35 3.62 3.52 3.41 TC 36 1 32 9 29 2 37 7 34 4 30 8 38 6 35 4 33 0 105 SHC 18.2 22.7 26.2 20.1 25.8 30.1 21.7 28.5 33.0 kW 3.78 3.65 3.50 3.86 3.72 3.58 3.90 3.76 3.66 TC 34 0 30.9 27 5 35 6 32 4 29 0 36 6 33 3 31 3 115 SHC 17.4 21.9 25.4 19 5 25 1 29 0 21 1 27 5 31.3 kW 404 389 372 413 397 382 417 402 3.92 6 48DJ005 (4 -TON) Temp (F) Air Ent Cond (Edb) Evap Alr - Cfm /BF 1200/.157 1600 /.194 1 2000/.226 Evap Air - Ewb (F) 72 67 62 72 67 62 72 87 62 TC 54 4 50 4 46 6 56 3 52 9 49 0 57.7 54 4 50 7 85 SHC 26.5 32.6 38 7 28.2 36.2 43 5 29.9 39.4 47.7 kW 4.43 4.29 4.15 4.52 4.39 4.25 4.56 4.44 4.31 TC 52 0 48 1 44.2 54 6 50.8 46.7 55 5 52 2 48.2 95 SHC 25.6 31.7 37.6 27.9 35.6 42.7 29.2 38.9 46.6 kW 4.75 4.60 4.44 4.87 4.72 4.56 4.90 4.77 4.61 TC 49.6 45.7 41 9 51 8 48 0 44 2 53 0 49.3 45 8 105 SHC 24.6 30.7 36.5 26,8 33.6 41.2 28.4 37.7 45 3 kW 5.07 4.89 4.73 5.18 5.01 4.84 5.23 5.07 4.92 TC 46 9 43 3 39.6 48 0 45 4 41 7 50 2 46 8 43.3 115 SHC 23.6 29.8 35.3 25.8 33.7 40 1 27.5 37.0 43 3 kW 538 5.22 502 550 533 5.14 556 5.41 523 • �2 C/-J2-4 48TC Gas Heat /Electric Cooling Packaged Rooftop 3 to 12.5 Nominal Tons Product Data WeatherMaker Carrier. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 2 2010 City of Tukwila BUILDING DIVISION r Carrier Turn to the Experts- FILE COPY - _ _ `7ma-:z-ma- - . ;---- Cam_ _ -` _ - .�_ f- 0 (Unit shown with optional economizer.) ENERGY STAR PARTNER This product has been designed and manufactured to meet Energy Star® cntena for energy a flciency. However, proper refngerant charge and proper air flow are critical to achieve reted capacity and efficiency. Installation of this product should follow all manufacturers refrigerant charging and air flow instruction. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. Puronry 0s .r: ronmentally.owm r.siesrv. C08514 RECEIVED CITY OFTUKV nLA FEB 2 6 2010 PERMIT CENTER MtOc?Vt TABLE 2 - ARI COOLING RATING TABLE 1 -STAGE COOLING UNIT COOUNG STAGES NOM. CAPACITY (TONS) NET COOLING CAPACITY (MBH) TOTAL POWER (KW) SEER EER IPLV A04 1 3 34.6 3.1 13.00 11.00 N/A &AO5. 0,4. 1• X430 45.0 4.0 ttt13100i- e• 11.00 N/A A06 1 5 59.0 5.5 13.00 10.75 N/A A07 1 6 70.0 6.4 N/A 11.00 N/A A08 1 7.5 88.0 8.0 N/A 11.00 N/A A09 1 8.5 97.0 8.8 N/A 11.00 N/A Al2 1 10 117.0 10.6 N/A 11.00 N/A TABLE 3 - ARI COOLING RATING TABLE 2 -STAGE COOLING UNIT COOUNG STAGES NOM. CAPACITY (TONS) NET COOLING CAPACITY (MBH) TOTAL POWER (KW) SEER EER IPLV 008 D12 D14 2 2 2 7.5 10 12.5 83.0 114.0 140.0 7.5 10.3 12.9 N/A N/A N/A 11.00 11.10 10.80 12.0 12.2 11.4 LEGEND ARI - Air Conditioning, Heating and Refrigeration Institute Test Standard ASHRAE - American Society of Heating, Refrigerating and Air Conditioning, Inc. EER - Energy Efficiency Ratio IPLV - Integrated Part Load Value SEER - Seasonal Energy Efficiency Ratio ARI Standard 210/240 UAC US ARI Standard 340/360 This product as been designed and manufactured to meet Energy Stara criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Instaltat,on of this product should follow all manufacturer's refrigerant charging and air flow Instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment Ufa. 8 NOTES: 1. Rated and certified under ARI Standard 210/240 -06 or 340/360 -07, as appropriate. 2. Ratings are based on: Cooling Standard: 80 °F (27 °C) db, 67 °F (19 °C) wb indoor air temp and 95 °F (35 °C) db outdoor air temp. IPLV Standard: 80 °F (27 °C) db, 67 °F (19 °C) wb indoor air temp and 80 °F (27 °C) db outdoor air temp, 3. All 48TC units comply with ASHRAE 90.1 2001, 2004 Energy Standard for minimum SEER and EER requirements. 4. 48TC units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http: / /bcap -energy.org. TABLE 4 — HEATING RATING TABLE - NATURAL GAS & PROPANE Units Gas Heat AL/SS HEAT EXCHANGER TEMP RISE (DEG F) THERMAL EFFICIENCY (M AFUE (%) INPUT / OUTPUT STAGE 1 (MBH) INPUT / OUTPUT STAGE 2 (MBH) LOW - 72 / 59 25 - 55 82% 81% 04 MED - 115 / 93 55 - 85 80% 80% HIGH - - - - _ LOW - 72 / 59 25 - 55 82% 81% le F 05 MED - 115 / 93 35 - 65 81% 80% HIGH - 150 / 120 50 - 80 80% 80% LOW - 72 / 59 20 - 55 82% 81% 06 MED - 115 / 93 30 - 65 81% 80% HIGH - 150 / 120 40 - 80 80% 80% j i Three Phase LOW - 72 / 59 25 - 55 82% N/A 04 MED 82 / 66 115 / 93 55 - 85 80% N/A HIGH - - - - - ILOW — - t72 / 59 - 25 - 55 82% N/A 05 MED - 115 / 93 35 - 65 81% N/A HIGH 120 / 96 150 / 120 50 - 80 80% N/A LOW - 72 / 59 20 - 55 82% N/A 06 MED - 115 /93 30 -65 81% N/A HIGH 120 / 96 150 / 120 40 - 80 80% N/A LOW - 72 / 59 15 - 55 82% N/A 07 MED - 115 / 93 25 - 65 81% N/A HIGH 120 / 96 150 / 120 35 - 80 80% N/A LOW - 125 / 103 20 - 50 82% N/A 08 MED 120 / 98 180 / 148 35 - 65 82% N/A HIGH 180 / 147 224 / 184 45 - 75 82% N/A LOW - 125 / 103 20 - 50 82% N/A 09 MED 120 / 98 180 / 148 30 - 65 82% N/A HIGH 180 / 147 224 / 184 40 - 75 82% N/A LOW 120 / 98 180 / 148 25 - 65 82% N/A 12 MED 180 / 147 224 / 184 30 - 65 82% N/A HIGH 200 / 160 250 / 205 35 - 70 80% N/A LOW 120 / 98 180 / 148 20 - 65 82% N/A 14 MED 180 / 147 224 / 184 25 - 65 82% N/A HIGH 200 / 160 250 / 205 25 - 70 80% N/A Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m). For information on Propane or alti- tudes above 2000 ft (610 m), see the Application Data section of this book. Accessory Propane /High Altitude kits are also available. In the USA the input rating for altitudes above 2000 ft (610m) must be derated by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating must be derated by 10% for altitudes of 2000 ft (610 m) to 4500 ft (1372 m) above sea level. 9 U H TABLE 5 - HEATING RATING TABLE - LOW NOX1 qzr UNIT GAS HEAT LOW NOx HEAT EXCHANGER TEMP RISE (DEG F) THERMAL EFFICIENCY (%) AFUE (To) INPUT / OUTPUT STAGE 1 (MBH) INPUT / OUTPUT STAGE 2 (MBH) 250 500 LOW - 60 / 50 20 - 50 81% 80% 80 04 MED - 90 / 74 30 - 60 81% 81% 63.9 vA05;e34 HIGH - - - - - 76.5 71.1 LOW - 60 / 50 20 - 50 81% 80% le l 05 MED - 90 / 74 30 - 60 81% 81% 1 78 HIGH - 120 /101 40 -70 81% 80% 66.3 62.7 LOW - 60 / 50 15 - 50 81% 80% 79.4 06 MED - 90 / 74 25 - 60 80% 81% 85.8 84.3 HIGH - 120 / 101 35 - 70 80% 81% Three Phase 1 LOW - 60 / 50 20 - 50 81% 80% 04 MED - 90 / 74 30 - 60 81% 81% 85.0 HIGH - - - - - D12 LOW - 60 / 50 20 - 50 81% 80% 05 MED - 90/74 30 -60 81% 81% 87.0 HIGH - 120 / 101 40 - 70 81% 80% 72.9 LOW - 60 / 50 15 - 50 81% 80% 06 MED - 90 / 74 25 - 60 80% 81% HIGH - 120 / 101 35 - 70 80% 81% NOTE: 1. Units meet California's South Coast Air Quality Management District (SCAQMD) Low -NOx emissions requirement of 40 nanograms per joule or less. TABLE 6 - SOUND PERFORMANCE TABLE UNIT COOLING OUTDOOR SOUND (dB) STAGES A- WEIGHTED 63 125 250 500 1000 2000 4000 8000 A04 1 80 90.6 80.9 80.2 76 74.6 71.3 68.5 63.9 vA05;e34 1 lett 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 A06 1 78 84.0 82.2 76.3 74.8 72.5 68.8 65.6 61.8 A07 1 78 88.8 81.8 76.9 74.4 73.3 69.8 66.3 62.7 A08 1 82 90.1 82.6 81.0 79.4 77.0 73.0 70.4 66.7 D08 2 82 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 A09 1 83 91.2 86.4 81.9 81.0 78.3 73.9 71.4 67.3 Al2 1 82 88.6 85.0 81.6 79.5 77.4 74.1 71.0 66.3 D12 2 82 89.0 83.1 80.5 78.5 75.5 71.6 69.6 69.3 D14 2 87 87.0 85.2 84.6 84.9 82.2 78.4 75.3 72.9 LEGEND dB - Decibel NOTES: 1. Outdoor sound data is measure in accordance with ARI standard 270 -2008. 2. Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure depends on specific environ- mental factors which normally do not match individual applications. Sound power values are independent of the environment and therefore more accurate. 3. A- weighted sound ratings filter out very high and very low frequencies, to better approximate the response of "average" human ear. A- weighted measurements for Carrier units are taken in accordance with ARI standard 270 -2008. 10 TABLE 8 - PHYSICAL DATA (COOLING) 3 - 6 TONS Refrigeration System # Circuits / # Comp. / Type Puron© refrig. (R -410A) charge per circuit NB (lbs-oz) Operating charge (lbs-oz) - Humidi -MiZer Unit Metering Device High - press. Trip / Reset (psig) Low - press. Trip / Reset (psig) 48TC *A04 t48TC *A05 48TC *A06 48TC *A07 1 / 1 / Scroll 5 -10 / - 8 -12 Acutrol 630 / 505 54 / 117 1 / 1 / Scroll 8 -8 / - 14 -13 Acutrol 630 / 505 54 / 117 1 / 1 / Scroll 10 -11 / - 16 -0 Acutrol 630 / 505 54 / 117 1 / 1 / Scroll 14 -2 / - 22 -4 Acutrol 630 / 505 54 / 117 Evap. Coil Material Coil type Rows /FPI Total Face Area (ft2) Condensate Drain Conn. Size Cu / Al 3/8° RTPF 2/15 5.5 3/4" Cu / Al 3/8" RTPF 2/15 5.5 3/4" Cu / Al 3/8" RTPF 4/15 5.5 3/4" Cu / Al 3/8" RTPF 4/15 7.3 3/4" Evap. Fan and Motor Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) 1 / Belt 1.2 560 -854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 560 -854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 2.4 1035 -1466 56 1 / Centrifugal 10 x 10 1 / Belt 1.2 560 - 854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 560 - 854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 2.4 1035 -1466 56 1 / Centrifugal 10 x 10 1 / Belt 1.2 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.5 1035 -1466 56 1 / Centrifugal 10 x 10 1 / Belt 1.5 770 -1175 48 1 / Centrifugal 10 x 10 1 / Belt 2.4 1035 -1466 56 1 / Centrifugal 10 x 10 1 / Belt 2.9 1303 -1687 56 1 / Centrifugal 10 x 10 - - - - - - - - - - - - 1 / Belt 2.4 1073 -1457 56 1 / Centrifugal 10 x 10 1 / Belt 2.9* 1173 -1518 56 1 / Centrifugal 10 x 10 1 / Belt 3.7 1474 -1788 56 1 / Centrifugal 10 x10 Standard Static 1 phase Medium Static 1 phase Standard Static 3 phase Medium Static 3 phase High Static 3 phase Cond. Coil Material Coil type Rows /FPI Total Face Area (ft2) Cu / Al 3/8" RTPF 1/17 14.6 Cu / Al 3/8" RTPF 2/17 16.5 Cu / Al 3/8" RTPF 2/17 16.5 Cu / Al 3/8" RTPF 2/17 21.3 Humidi - MIZer Coil Material Rows..Fins /in. Total Face Area (ft2) Cu / Al 1 / 17 3.9 Cu / Al 2 / 17 3.9 Cu / Al 2 / 17 3.9 Cu / Al 2 / 17 5.2 Cond. fan / motor Qty / Motor Drive Type Motor HP/ RPM Fan diameter (in) 1/ Direct 1/4/ 1100 22 1/ Direct 1/4/ 1100 22 1/ Direct 1/4/ 1100 22 1/ Direct 1/4/ 1100 22 Filters RA Filter # /Size(in) OA inlet screen # /Size(in) 2/16x25x2 1 /20x24x1 2/16x25x2 1/20 x 24x1 2/16x25 x2 1 /20x24x1 4/16x16x2 1/20x 24x1 * 575V motor utilizes 3.7 BHP 12 TABLE 9 - PHYSICAL DATA (HEATING) 3 - 6 TONS Gas Connection # of Gas Valves Nat. gas supply line press (in. w.g.) /(PSIG) Propane supply line press (in. w.g.) /(PSIG) Heat Anticipator Setting (Amps) 1st stage 2nd stage 48TC * *04 48TC * *05 48TC * *08 48TC * *07 1 4 —13 / 0.18 — 0.47 11 —13 / 0.40 — 0.47 0.14 0.14 1 4 —13 / 0.18 — 0.47 11 —13 / 0.40 — 0.47 0.14 0.14 1 4 —13 / 0.18 — 0.47 11 —13 / 0.40 — 0.47 0.14 0.14 1 4 —13 / 0.18 — 0.47 11 —13 / 0.40 — 0.47 0.14 0.14 Natural Q J 0 I _ 0 I Gas, Propane Heat # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) Connection size # of stages / # of burners (total) Rollout switch opens / closes Temperature rise range (F) 1 / 2 1/2" NPT 195 / 115 25 — 55 1 or 2 / 3 1/2" NPT 195 / 115 55 — 85 — — — — 1 / 2 1/2" NPT 195 / 115 25 — 55 1 / 3 1/2" NPT 195 / 115 35 — 65 1 or 2/ 3 1/2" NPT 195 / 115 50 — 80 1 / 2 1/2" NPT 195 / 115 20 — 55 1 / 3 1/2" NPT 195 / 115 30 — 65 1 or 2/ 3 1/2" NPT 195 / 115 40 — 80 1 / 2 1/2" NPT 195 / 115 15 — 55 1 / 3 1/2" NPT 195 / 115 25 — 65 1 or 2/ 3 1/2" NPT 195 / 115 35 — 80 Low 0 J 0 I = 0 = NOx Gas Heat # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) # of stages / # of burners (total) Connection size Rollout switch opens / closes Temperature rise range (F) 1 / 2 1/2" NPT 195 / 115 20 — 50 1 / 3 1/2" NPT 195 / 115 30 — 60 — — — — 1 / 2 1/2" NPT 195 / 115 20 — 50 1 / 3 1/2" NPT 195 / 115 30 — 60 1 / 3 1/2" NPT 195 / 115 40 — 70 1 / 2 1/2" NPT 195 / 115 15 — 50 1 / 3 1/2" NPT 195 / 115 25 — 60 1 / 3 1/2" NPT 195 / 115 35 — 70 — — — — — — — — — - — 13 U co CURBS & WEIGHTS DIMENSIONS - CHASSIS 1 NOTES: 1. DIMENSIONS ARE IN INCHES DIMENSIONS IN ( 1 ARE IN NILLINETERS. 2. ® CENTER OF GRAVITY 3. 6 -1/8 11551 DIRECTION OF AIR FLOW 44 321/4 (8181 33 3/8 (848] 18 -1/8 I I [459] 141/8 14-1/4 [312]4 [4111] SEE THRU THE BASE CHART • • t ECONOMIZER HOOD (OPTIONAL) 25 -5/8 16521 RETURN AIR E ALT. I - CONDENSATE 11 -3/4 DRAIN OPENING (4511 IN BASEPAN SUPPLY AIR 44- 10-1/2 12651 E STD.- CONDENSATE DRAIN CONNECTION SIZES 25 -1/8 [638] , RETURN AIR 1 3/8" DIA [35] FIELD POWER SUPPLY HOLE B 2° ISO] DIA POWER SUPPLY KNOCKOUT I 16 -3/4 0 11 [1271 SUPPLY AIR o D - - -- E 3/4' -14 NPT CONDENSATE DRAIN E 1/2'-14 NPT GAS CONNECTION 6 -5/8 [168] I- (177] 26 3/4 16811 t 6 [1521 31 114-. SUPPLY (793) AIR AIR IR *RIGHT 1 -1 /4 [321 IL TER OUTSIDE AIR 21 -114 [5391 BAROMETRIC RELIEF FLOW 4 -5/8 (1181 LECTRICAL DISCONNECT LOCATION OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 19 -1/2 [4941 3 -3// [951 46 3/4 [1187] FT 25 [6361 4 [100] FLUE H000 TOP 16 (4061 10 -7/8 (277] 26 -1/2 [673] RETURN AIR 29 -3/8 [7471 3-3/8 f85 12 -1 /8 ] [307] 18 1/2 [470] SUPPLY AIR OPTIONAL FACTORY INSTALLED DISCONNECT ANDLEJ 30 1/8 [164] 74 3/8 118881 FRONT FILTER ACCESS PANEL (TOOL -LESS) 1 • CONNECTION SIZES A 1 3/8" DIA [35] FIELD POWER SUPPLY HOLE B 2° ISO] DIA POWER SUPPLY KNOCKOUT C 1 3/4" DIA [51] GAUGE ACCESS PLUG D 7/8' DIA [221 FIELD CONTROL WIRING HOLE E 3/4' -14 NPT CONDENSATE DRAIN E 1/2'-14 NPT GAS CONNECTION G 2 1/2 ° DIA [64] POWER SUPPLY KNOCK-OUT 25 [6361 4 [100] FLUE H000 TOP 16 (4061 10 -7/8 (277] 26 -1/2 [673] RETURN AIR 29 -3/8 [7471 3-3/8 f85 12 -1 /8 ] [307] 18 1/2 [470] SUPPLY AIR OPTIONAL FACTORY INSTALLED DISCONNECT ANDLEJ 30 1/8 [164] 74 3/8 118881 FRONT FILTER ACCESS PANEL (TOOL -LESS) 1 • J COMP. • ACCESS . PANEL ' rm CONDENSER COIL INDOOR COIL ACCESS PANEL ' 1/2' ACC. THRU- THE -BASE CHART THESE HOLES REQUIRED FOR USE CRBTMPWROO1A01, 003401 J THREADED CONDUIT SIZE WIRE USE REQ'D HOLE SIZES (MAX.) W 1/2' ACC. 1/8° (22.2) X 1/2' 24V 7/8" (22.2) Y 4 3/4' (001,003) POWER 1 1/8" (28.4) Z44 (003) 1/2' FPT GAS 1 3/16' (30.01 FOR "THRU - THE - BASEPAN' FACTORY OPTION, FITTINGS FOR ONLY X,Y, & Z ARE PROVIDED 4 SELECT EITHER 3/4° OR 1/2' FOR POWER, DEPENDING ON WIRE SIZE 4f (001) PROVIDES 3/4" FPT THRU CURB FLANGE R FITTING. Fig. 1 - Dimensions 48TC 04 -07 16 BACK 2 -5/8 -.4 [67] TYP CURB WIDTH UNIT J K 48TC 404 33 3/8 (8471 18 5/8 [412] 48TC 405 33 3/8 (8411 14 7/8 [377] 48TC 406 33 3/8 (8471 14 1/8 [3771 487C 407 41 3/8 (1051] 14 7/8 [371] C08517 • CURBS & WEIGHTS DIMENSIONS - CHASSIS 1 (cont.) UNIT STD. UNIT WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (Cl CORNER WEIGHT (D) SUPPLY AIR OPENING C.G. Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non — conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 —ft of unit fresh air intake hood HEIGHT LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 48TC -A04 483 219 111 50 125 57 131 59 116 53 39 [991] 23 [584] 16 3/8 [4161 48TC 'A05 053;7 244 124 56 139 63 145 66 129 59 39 [9911 23 [584] 17 [432] 48TC -A06 569 258 131 59 147 67 154 70 137 62 39 [991] 23 [584] 11 1/4 [438] '4$T.C' A07 9,6521. 296 150 68 169 76 176 80 151 71 39 [991] 23 [5841 20 1/8 [511 ] CORNER A CORNER D TOP 0' -3' [76] 0' -3' C76] 1' -1 7/16' (341) 0'-0 7/16' [11] (BOLT HEADS) 0' -0 7/16' [11] (BOLT HEADS) CORNER B LOO f .1 : o 0_6 CORNER C FRONT C08593 Fig. 2 - Dimensions 48TC 04 -07 2' -7 5/8- 1803] o- I' -7 13/16' ('I 1/B' O' -0 7/16' 05041 P (334) CI11 0' -3- " (BOLT HEADS) [76] 3' -0 0' -0 7/16' C914) [11] (BOLT HEADS) Fig. 3 - Curb Dimensions C07458 GASKET '(SUPPLIED WITH CURB) NAIL COUNTER FLASHING (FIELD SUPPLIED) _'ROOFING FELT (FIELD SUPPLIED) CANT STRIP ! _' FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) C07457 Fig. 4 - Curb Installation Detail (Typical) Fig. 5 - Service Clearance C08337 LOC / t \ ` I 1 1 / / / \r / / / 6/ CONDITION A RETURN AIR 6k, OPENING Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance SUPPLY AIR OPENING 42" (1067 mm) 36" (914 mm) Special CORNER B LOO f .1 : o 0_6 CORNER C FRONT C08593 Fig. 2 - Dimensions 48TC 04 -07 2' -7 5/8- 1803] o- I' -7 13/16' ('I 1/B' O' -0 7/16' 05041 P (334) CI11 0' -3- " (BOLT HEADS) [76] 3' -0 0' -0 7/16' C914) [11] (BOLT HEADS) Fig. 3 - Curb Dimensions C07458 GASKET '(SUPPLIED WITH CURB) NAIL COUNTER FLASHING (FIELD SUPPLIED) _'ROOFING FELT (FIELD SUPPLIED) CANT STRIP ! _' FIELD SUPPLIED) ROOFING FELT (FIELD SUPPLIED) C07457 Fig. 4 - Curb Installation Detail (Typical) Fig. 5 - Service Clearance C08337 LOC DIMENSION CONDITION A 48" (1219 mm) 18" (457 mm) 18" (457 mm) 12" (305 mm) Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance B 42" (1067 mm) 36" (914 mm) Special Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non — conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 —ft of unit fresh air intake hood C 36" (914 mm) 18" (457 mm) Side condensate drain is used Minimum clearance D 48" (1219 mm) 42" (1067 mm) 36° (914 mm) Special No flue discharge accessory installed, surface is combustible material Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non — conductive (e.g., wood, fiberglass) Check for adjacent units or building fresh air intakes within 10 —ft of this unit's flue outlet 17 0 I— a a � PERMIT COORD COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -028 DATE: 02/26/10 PROJECT NAME: STARBUCKS COFFEE SITE ADDRESS: 333 STRANDER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPART ENTS: ui1d ing 'vision L Public Works 4W1 O Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 03/02/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/30/10 Approved ❑ Approved with Conditions Er Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name T E C Mechanical Service Co UBI No. 600291892 Phone 4258813247 Status Active Address Po Box 3550 License No. TECMESC143BA Suite /Apt. License Type Construction Contractor City Redmond Effective Date 1/1/1986 State Wa Expiration Date 2/1/2011 Zip 980733550 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BBMECS'192MU B &Amp; B Mechanical Services Inc Construction Contractor General Unused 7/31/1981 1/1/1986 Archived Business Owner Information Name Role Effective Date Expiration Date Francis, Charles D &Nbsp; 01/01/1980 Bond Amount Baldwin, Joan M &Nbsp; 01/01/1980 6350122 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 • AM STATES INS 6350122 05/24/2005 Until Cancelled $12,000.00 05/23/2005 7 AM STATES INS 6219554 05/24/2003 Until Cancelled 05/24/2005 $12,000.00 05/12/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 21 AMERICAN FIRE & CAS BKA53856277 06/13/2009 06/13/2010 $1,000,000.0006 /10/2009 20 CONTINENTAL WESTERN GROUP CNP2693909 06/13/2007 06/13/2009 $1,000,000.00 05/30/2008 19 NORTH PACIFIC INS CO CO2163753 06/13/2006 06/13/2007 $1,000,000.0006 /14/2006 18 OREGON AUTO INS CO C01163753 06/13/2005 06/13/2006 $1,000,000.00 02/28/2006 17 FEDERATED MUTUAL INS CO 3197506 03/01/2005 03/01/2006 $1,000,000.00 03/25/2005 16 OHIO CAS INS BK00653050489 03/01/2005 03/01/2006 $1,000,000.00 02/25/2005 15 OHIO CAS INS BK053050489 03/01/2004 Until Cancelled $1,000,000.00 04/03/2003 14 ST INS COS BK01103376 BK01103376 02/01 /2002 Until Cancelled 02/01/2002 https://fortress.wa.gov/lni/bbip/Print.aspx 03/05/2010