Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M10-033 - TOYS R US / BABIES R US
TOYS R US /BABIES R US 1750 SOUTHCENTER PY SUITE 300 M10 -033 City 4fukwila d Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 2623049067 Address: 17501 SOUTHCENTER PY TUKW Project Name: TOYS R US / BABIES R US Permit Number: M10 -033 Issue Date: 06/15/2010 Permit Expires On: 12/12/2010 Owner: Name: CLPF - TUKWILA LP Address: C/O JSH PROPERTIES INC , 10655 NE 4TH ST #300 98004 Contact Person: Name: RYAN NOAKES Address: 1811 4 MILE ROAD NE , GRAND RAPIDS MI 49525 Email: Contractor: Name: SUN GLOW INC Address: 2428 S 105 , PORTLAND OR 97216 Contractor License No: SUNGLI *088RB Phone: 616- 447 -3437 Phone: 503 253 -7789 Expiration Date: 02/14/2012 DESCRIPTION OF WORK: THIS IS A TENANT FTFOUT OF AN EXISTING RETAIL SPACE. OUR CLIENT WILL TAKE OVER TWO SPACES AND COMBINE INTO ONE. THERE ARE 10 EXISTING RTU'S. OF THESE, ONE WILL BE ABANDONED. WE WILL FOUR ADDTFIONAL RTU'S, ALL 7.5 TONS OR SMALLER. ONE EXISTING UNIT WILL REMAIN. WE WILL ALSO ADD ONE NEW 2 -TON DUCTLESS SPLIT. THE BUILDING BAS WILL BE UPGRADED TO A NEW AUTOMATED LOGIC SYSTEM Value of Mechanical: 100,000.00 Type of Fire Protection: SPRINKLERS /AFA 1,11 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be compli Fees Collected: $1,305.06 International Mechanical Code Edition: 2009 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr- - e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. don: IMC -4/10 M10-033 Printed: 06 -15 -2010 � o City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049067 Address: Suite No: Tenant: 17501 SOUTHCENTER PY TUKW TOYS R US / BABIES R US PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10 -033 ISSUED 03/11/2010 06/15/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDMONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Cond -10/06 M10 -033 Printed: 06 -15 -2010 • A City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.i a. us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 -575 -4407 for ordering information. 21: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -033 Printed: 06 -15 -2010 • o City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. s laSignature: Date: r /(1— Print Name: ordinances governing or local laws regulating doc: Cond -10/06 M10 -033 Printed: 06 -15 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permi C) No. 1)10 7 Mechanical Permit No. L0 Plumbing/Gas Permit No. \>C 1' ©3 (o Public Projec Works Permit. No. No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 430Ll — 10 7 Site Address: 17501 Southcenter Parkway Suite Number: 300 Floor: Tenant Name: Toys "R" Us / Babies "R" Us Property Owners Name: JSH Properties, Inc. - John Chelico Mailing Address: 2003 Western Ave, Suite 200 New Tenant: J Yes El ..No Seattle WA 98121 City State Zip CONTACT PERSON who do we contact when your permit is ready to be issued Name: Ryan Noakes - PAEP Architecture Engineering, P.C. Mailing Address: 1811 4 Mile Road, NE Day Telephone: (616) 447 -3437 Grand Rapids MI 49525 E -Mail Address: noakesr @progressiveae.com City State Fax Number: (616) 361 -1493 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: TBD Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamp by Architect Record Company Name: PAEP Architecture Engineering, P.C. Mailing Address: 1811 4 Mile Road, NE Contact Person: Doug Wurl Grand Rapids MI 49525 E -Mail Address: wurld @progressiveae.com City State Day Telephone: (616) 447 -3439 Fax Number: (616) 361 -1493 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Structural Associates, Inc. Mailing Address: 62 Commerce Avenue, SW, Suite 100 Grand Rapids MI 49503 City State Contact Person: Dirk Buttke Day Telephone: (616) 457 -8100 E -Mail Address: dbuttke @gowithsai.com Fax Number: (616) 457 -8107 H:V+pplications\Fotms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Zip Page 1 of 6 BUILDING PERMIT INFORMA. TION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 2,000,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): Renovation of existing (former) Linens & Things and K &G Fashion Superstore, including front elevation modifications and interior renovation (new toilet rooms, offices, break/training room, sales fixtures, finishes, etc.) Will there be new rack storage? ® Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 155 Compact: 131 Handicap: 6 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 ApplicationsU -2009 - Permit Application.doc Revised: 1 -2009 bb Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 58,132 58,132 0 58,132 IIB Mercantile 2 "a Floor 3ra Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 155 Compact: 131 Handicap: 6 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 ApplicationsU -2009 - Permit Application.doc Revised: 1 -2009 bb Page 2 of 6 M ECHANICAL F� R MIT F O R_ MAT ION — 20 6 -.4. 31 -3.6. 70 f . MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 100,000 Scope of Work (please provide detailed information): This is a tenant fitout of an existing retail space. Our client will take -over two spaces and combine into one. There are 10 existing RTU's. Of these, one will be abandoned. We will four addtinoal RTU's, all 7.5 tons or smaller. One existing unit heater will remain. We will also add one new 2 -ton ductless split. The building BAS will be upgraded to a new Automated Logic System. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... Fuel Type: Electric ❑ Gas .... ® Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM 0 Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 13 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment 1 Air Handling Unit <10,000 CFM 4 Incinerator — Comm/Ind H:\Applications \Forms - Applications On Lme\2009 Appheations \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN 0 : TH ZED AGENT: Signature: i Print Name: Ryan T. Noakes Mailing Address: 1811 4 Mile Road, NE Date: 03/09/2010 Day Telephone: (616) 447 -3437 Grand Rapids MI 49525 City State Zip Date Application Accepted: ` Date Application Expires: ( Staff Initials: i _ / I H:Wpplications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 • 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049067 Permit Number: M10 -033 Address: 17501 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 03/11/2010 Applicant: TOYS R US / BABIES R US Issue Date: Receipt No.: R10 -00432 Initials: User ID: Payee: WER 1655 Payment Amount: $261.01 Payment Date: 03/11/2010 02:17 PM Balance: $1,044.05 PROGRESSIVE /AE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 38392 261.01 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 261.01 Total: $261.01 ENT RECEIVE doc: Receiot -06 Printed: 03 -11 -2010 INSPECTION RECORD 1 V0 Retain a copy with permit INSPECTION NO PERMIT NO. CITY OF'TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro ct: u5 .5 Type f Inspec 'on: r ,e -- Addres3: �r ic p it Date Called: ' A A t✓ Special Instructions: 7,,,,oa- Pfx-i Date Wanted: l r-- -� - o . pm:. Requester: Phone No: Approved per applicable codes. F ElCorrections required prior to-approval: ��7 COMMENTS: S if G:4- -4 ,.f e c..17; t i / � r -f OA a:.1 S } P firs tP r - Inspg;Ltor: y 'Date: ( j -(J REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd:; Suite 100. Call to schedule reinspection. • . • - . •c∎ . - • INSPECTION O. INSPECTION RECORD Retain a copy with permit M1-O33 PERMIT NO. •. CITY OF TUKVVILA BUILDING DIVISION . . 6300 Southcenter Blvd., #100;:.TUkwili.-•A*98188 r. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 4.1 aroett: (.6 Lf aej 4 (13 Type of Ihtpecti n: ',1 ik.141 cil Addrest 1 /ISA I 5 C ArkL4444/ Date Called: Special Instructions: • Date.Wanted: ---X1-"W p.m. Requester: Phone No: gri.)•-aql* 0 - To37 El Approved per applicable codes. • tim s required prior to approval. rrec COMMENTS: k WtO pJ 14;trei- fai r rAtei 6 1,\ k iss A sr--ro. M Insp (tor: tk) Date: -41--10 REINSPECTION FEE REQUIRED. Prior to next ihtpeetion. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to 'schedule reinspection. INiataarcksips:tat • x • v• .'• . . ...a. • e• • mr..Jc77,--. +. r. INSPECTION RECORD MWv`033 Retain a copy with permit INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION r. 6300 Southcenter Blvd., #100; Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project, Type of Inspection Address: Date C qtti Spdcial Instructions: • . Date Wanted: ! a.m. Requester: Phone No: '' Approved per applicable codes. ❑.Corrections required prior to approval. COMMAENTS: p a i d .;x n • ector: Date,, .Q REINSPECTION FEE R_ (WIRED. Prior to -next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection:' • his • INSPECTION RECORD Retain a copy with permit _4O -643 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd:, #100, TukwiIa. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 P oject: S f6P �+ Type of Inspect' n: AddAresIst: Date Called: Special Instructions: %Date Wanted: q j a.m. Requester: Phone No: Approved per applicable codes. . a Corrections required prior to approval. COMMENTS: k1U Awl -',° ?P . Inspect is cpurk REINSPECTION FEE REQUIRED. rior to next inspection. fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 0 Rr:A.rm... • S#i4!•r•.th.... • .1. F r '41tR.4''. -- wl=FP+ar.a-.,. 7 :.: INSPECTION RECORD Retain a copy with permit Mtd -613'3 INSPECTION NO. PERMIT NO. ' • CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pr_,pdect: I ,t (%.S )e Type of Inspection: S - • a-,. � 11: ; .� Address f 50 A.444 Date , ed: 4, Special Instructions: • Date Wanted: �''' 21 I Q a.m. Requester: Phone No: 7 Approved per applicable codes. Corrections required prior toy approval. COMMENTS: 10 De.r— -. As ( f 1 ,tf( (14'.41k) 0*, REINSPECTION FEE REQUIRED. rior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Insp ec Date -,r , apewrt ... ••• ... . t 4Pci INSPECTION NO. INSPECTION RECORD Retain a copy with permit "-4'0-033 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIIT__ NO. (206)431 -3670 P.Cgject: 1 es �s R Ls �3a . C.� Type Inspectign: �p JLi ' (,, Ti ,�l e I�G Address: i rl o l s � k1� Date Called: Special Instructions: eV �`� c (ten/ Se- -.s / :/k A^ AAf,�sr,�A. ` L.vi L Date Wanted: -% -, d p.m. Requester: Phone No: z0Y -Xo0 —•3 (39 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: PA :04'1 q�?pn J / 47 e1 �i- ter-Li IJ-Gli .`''C.�(A el //` /, . It S 4-- -1 7Zi1 U4 7 6/d. Oc / Nit-td 2n.1 ( ;j / @-).s---ii / ,.It -LJ rcrd 0 cr.') L a irk ( -- -T OkI ( .e' /-A p r-- + , ,-1� 'AJ � 61 ,.. 4 poi Kg ,� j A-41 vi / A P m a r i, J _,r-e..' s o .' c prnJ.A-A (..___13cedc (®9a l e r-t) a PA `1/4-e J1 6^ l{ w c>g Mwter 1 C 6A(- f.Se- iJ rv^ JA 1 5,2 h INA- (\/ 6,-I.PW - -1) 4 L `,lei Ins(;ctor: Date: r 4-7 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4/ - .. — - a ._...� - * -- - - .. INSPECTION RECORD Retain a copy with permit /firio-u33 i —, Ci PERMIT NUMBERS !C? l'_ J) CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 INSPECTION NUMBER Project: J}w ' i V s Sprinklers: Type of Inspection: /tilm in � i ci ei -,e,-.4-- ! i /74- , ., 1 / i Address: .! o y s 'r ' v s ar 7 °, Suite #: 410o 5 c. (' 7' Contact Person: t f Special Instructions: Phone No.: ate?- 3 (00 eo?Yi Approved per applicable codes. ElCorrections required prior to approval COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: � r t i f +--r.-1 i 1t jo T- Odd ( �,it ./ S. ;'L 11 ab1i c. tit i 17fi?j�S hi" �9, rP' Y0l t.!pit f`Ct Lite C +. , 1 1141. :.., f 1 i r J`i? — c k 1 ✓ v it)-• i Y s � i ,..„.1 't h.4.,',;t i' +rG -. . t r e ►_, t ;, :3I' 5 y L • . A i 9 ? r C �AA r -.2 / 1 4a t r ,4,-;,,,. ;�r'4... , (-) Li 1. C.. 1, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: Hrs.: $80.00 itEINSPECTION FEE REQUIRED. You will receive an invoice from the Gay of Tukwi a .µ a p • . rtrnent. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 o o a Project Name: Location: Architect: Engineer: Contractor: EAGLE TEST & BALANCE COMPANY AABC CERTIFIED 815 E. Main Cushing, OK 74023 Phone: 918 - 225 -1668 Fax: 918 - 225 -1687 13047 S.E. 47th Place Bellevue, WA 98006 Phone: 425 - 747 -9256 Fax: 425 - 641 -5662 TEST AND BALANCE REPORT Toys R US - Babies R US Tukwila, WA Paep Architecture Engineering Sun Glow, Inc. Project Number: ETB -10 -1469 t v This is to certify that Eagle Test & Balance has balanced the systems described herein to their optimum performance capabilities. The testing and balancing has been performed in accordance with the standard requirements and procedures of the Associated Air Balance Council and the results of these tests are herein recorded. Associated Air Balance Council Certification Number: 93 -02 -01 Date: 10/5/10 Form #89010 1 o 0 0 EAGLE TEST & BALANCE COMPANY Project Name: Babies R US System: RTU -A1, A2, A3 AW- .aa.4Bc Project #: ETB -10 -1469 Date: 10/5/10 AIR DISTRIBUTION TEST SHEET Term # Rm # Term Term Factor Design FPM Design CFM Test FPM or CFM Final Final Type Size Test 1 Test 2 Test 3 FPM CFM RTU -A1 1 S -3 18x8 1.0 500 455 500 500 2 S -3 18x8 1.0 500 490 520 520 3 S -8 24x12 1.0 1000 1160 1035 1035 4 S -7 24x12 1.0 1000 1095 1010 1010 5 S -3 18x8 1.0 500 490 500 500 6 S -3 18x8 1.0 500 525 495 495 RTU -A2 1 S -3 24x12 1.0 1000 945 990 990 2 S -3 24x12 1.0 1000 1200 1000 1000 3 S -3 24x12 1.0 1000 860 975 975 4 S -3 18x8 1.0 500 460 480 480 5 S -3 18x8 1.0 500 520 500 500 RTU -A3 1 DL 24x3.5 .583 1715 1000 1086 926 1588 926 2 DL 24x3.5 .583 1715 1000 1148 1072 1839 1072 3 DL 24x3.5 .583 1715 1000 1144 1020 1749 1020 4 DL 24x3.5 .583 1715 1000 1156 1080 1852 1080 Remarks: DL= DRUM LOUVER Form #1.5.10 2 O 0 EAGLE TEST & BALANCE COMPANY Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -A4, A5 AIR DISTRIBUTION TEST SHEET Term # Rm # Term Term Factor Design FPM Design CFM Test FPM or CFM Final Final Type Size Test 1 Test 2 Test 3 FPM CFM RTU -A4 1 DL 24x3.5 .583 1715 1000 1012 1736 1012 2 DL 24x3.5 .583 1715 1000 1027 1762 1027 3 DL 24x3.5 .583 1715 1000 1048 1798 1048 4 DL 24x3.5 .583 1715 1000 960 1647 960 RTU-A5 1 S -3 14x8 1.0 250 305 255 255 2 S -3 24x12 1.0 1000 1000 1010 1010 3 S -3 14x8 1.0 250 290 250 250 4 S -3 18x8 1.0 500 450 490 490 5 S -3 24x12 1.0 1000 960 980 480 Remarks: DL= DRUM LOUVER Form #1.5.10 3 O O O EAGLE TEST & BALANCE COMPANY Project Name: Babies R US System: RTU -1 thru RTU-4 4n4easac Project #: ETB -10 -1469 Date: 10/5/10 AIR DISTRIBUTION TEST SHEET Term # Rm # Term Term Factor Design FPM Design CFM Test FPM or CFM Final Final Type Size Test 1 Test 2 Test 3 FPM CFM RTU -1 1 DL 50x6 2.083 1260 2625 2720 1306 2720 2 DL 50x6 2.083 1260 2625 2631 1263 2631 3 DL 50x6 2.083 1260 2625 2767 1328 2767 4 DL 50x6 2.083 1260 2625 2615 1255 2615 RTU -2 1 DL 50x6 2.083 1260 2625 2654 1274 2654 2 DL 50x6 2.083 1260 2625 2744 1317 2744 3 DL 50x6 2.083 1260 2625 2792 1340 2792 4 DL 50x6 2.083 1260 2625 2637 1266 2637 RTU -3 1 DL 40x6 1.67 1347 2250 2148 2158 1292 2158 2 DL 40x6 1.67 1347 2250 2417 2240 1341 2240 3 DL 40x6 1.67 1347 2250 2527 2338 1400 2338 4 DL 40x6 1.67 1347 2250 2533 2343 1403 2343 RTU-4 1 DL 40x6 1.67 1347 2250 2485 2176 1303 2176 2 DL 40x6 1.67 1347 2250 2612 2258 1352 2258 3 DL 40x6 1.67 1347 2250 2495 2495 1295 2163 4 DL 40x6 1.67 1347 2250 2266 2266 1245 2079 Remarks: DL =DRUM LOUVER Form #1.5.10 4 O • • EAGLE TEST & BALANCE COMPANY Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -8, RTU -9 AIR DISTRIBUTION TEST SHEET Term # Rm # Term Term Factor Design FPM Design CFM Test FPM or CFM Final Final Type Size Test 1 Test 2 Test 3 FPM CFM RTU -8 1 102 S -4 4 -1x48 1.0 375 395 370 370 2 102 S -4 4 -1x48 1.0 375 425 385 385 3 101 S -4 4 -1x48 1.0 375 405 390 390 4 101 S -4 4 -1x48 1.0 375 320 375 375 5 103 S -4 4 -1x48 1.0 375 350 380 380 6 103 S -4 4 -1x48 1.0 375 315 360 360 R1 R7 24x24 1.0 1060 1130 R2 R7 24x24 1.0 1060 995 RTU -9 1 119 S -3 18x8 1.0 280 205 295 295 2 106 S -1 8" 1.0 200 120 190 190 3 112 S -2 6" 1.0 140 90 130 130 4 111 S -1 6" 1.0 140 120 140 140 5 110 S -3 8x6 1.0 100 75 95 95 6 S -1 8" 1.0 170 155 180 185 7 S -1 8" 1.0 170 125 170 170 R1 119 R8 18x8 1.0 95 105 R2 106 R7 8" 1.0 200 190 R3 112 R6 10x10 1.0 140 130 R4 111 R7 8" 1.0 140 135 R5 101 R7 8" 1.0 440 450 Remarks: Form #1.5.10 5 A 0 0 EAGLE TEST & BALANCE COMPANY MIL .11.0aAIPC Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -10, RTU -11, EF -1 AIR DISTRIBUTION TEST SHEET Term # Rm # Term Term Factor Design FPM Design CFM Test FPM or CFM Final Final Type Size Test 1 Test 2 Test 3 FPM CFM RTU -10 1 DL 24x3.5 .583 1286 750 796 729 1250 729 2 DL 24x3.5 .583 1286 750 834 764 1310 764 3 DL 24x3.5 .583 1286 750 854 782 1341 782 4 DL 24x3.5 .583 1286 750 816 747 1281 747 RTU -11 1 108 S -1 8" 1.0 220 120 225 235 2 118 S -1 10" 1.0 250 250 290 270 3 118 S -1 10" 1.0 250 240 295 265 4 124 S -1 8" 1.0 130 235 120 140 5 123 S -2 8" 1.0 180 290 195 195 6 122 S -2 8" 1.0 180 150 190 190 7 119 S -3 18x8 1.0 390 305 385 375 R1 108 R7 10" 1.0 220 225 R2 119 R8 18x8 1.0 390 415 R3 118 R7 12" 1.0 500 500 R4 113 R7 10" 1.0 290 300 EF -1 E1 122 E5 12x12 1.0 410 360 430 405 E2 123 E5 12x12 1.0 410 270 310 400 E3 125 E6 6x6 1.0 70 90 110 75 E4 124 E6 8x8 1.0 210 200 230 200 Remarks: DL= DRUM LOUVER Form #1.5.10 6 0 0 0 EAGLE TEST & BALANCE COMPANY AIL Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -Al, RTU -A2 EXISTING AIR MOVING EQUIPMENT DATA FAN RTU -A1 RTU -A2 Equipment Location ROOF ROOF Area Served STORAGE/NORTH WALL STORAGE Equipment Manufacturer LENNOX LENNOX Model GCS24- 1353 -270 -1G GCS24 -1353 -270 -1G Serial Number 5695K04829 5695L01804 Motor Sheave & Shaft Specified Actual Specified Actual Total CFM -Fan 4000 4060 4000 3945 Total CFM- Outlet 4000 4060 4000 3945 R/A CFM 3570 3610 3570 3510 0/A CFM 430/1060 450 430/1060 435 Tot/Ex Static Pressure .5 .48 .5 .47 Inlet Pressure * -.32 * -.30 Discharge Pressure * .16 * .17 Fan RPM * 925 * 915 Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg MAGNETEK MAGNETEK MAGNETEK MAGNETEK Motor HP/BHP 3 3 3 3 Phase/Hz 3 3 3 3 Voltage 460 484/484/482 460 482/484/484 Amperage 4.4 4.3/4.3/4.2 4.8 4.1/4.0/4.0 Motor RPM 1725 1730 1725 1735 Motor Sery Fac/Frame # 1.15 1.15 1.15 1.15 Starter Location/Size * * * * O.L. Heater Size/Rating * * * * Motor Sheave & Shaft VP50x7/8" 4 3/4 "ODx7 /8" Fan Sheave & Shaft 81/4 "ODx1" 81/4 "ODx1" Belt Size/Number BX51 B51 Sheave Adjustment * * CtoC/MotorMountAdj * I In * 1 Out * * I In * I Out * Remarks: Form #1.5.5 7 • O O EAGLE TEST & BALANCE COMPANY ANL Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -A3, RTU -A4 EXISTING AIR MOVING EQUIPMENT DATA FAN RTU -A3 RTU -A4 Equipment Location ROOF ROOF Area Served RETAIL RETAIL Equipment Manufacturer LENNOX LENNOX Model GCS24 -1353- 270 -1G GCS24 -1353- 270 -1G Serial Number * 5695K04832 Motor Sheave & Shaft Specified Actual Specified Actual Total CFM-Fan 4000 4098 4000 4047 Total CFM- Outlet 4000 4098 4000 4047 R/A CFM 3570 3648 3570 3607 0/A CFM 430/1060 450 430/1060 440 Tot/Ex Static Pressure .5 .48 .5 .47 Inlet Pressure * -.31 * -.31 Discharge Pressure * .17 * .16 Fan RPM * 965 * 960 Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg MAGNETEK MAGNETEK MAGNETEK MAGNETEK Motor HP/BHP 3 3 3 3 Phase/Hz 3 3 3 3 Voltage 460 i 480/482/482 460 482/481/481 Amperage 4.4 3.0.6/3.5 4.4 3.7/3.03.5 Motor RPM 1725 1735 1725 1735 Motor Sery Fac/Frame # 1.15 1.15 1.15 1.15 Starter Location/Size * * * * O.L. Heater Size/Rating * * * * Motor Sheave & Shaft VP50x7/8" 4 3/4 "ODx7/8" Fan Sheave & Shaft 81/4 "ODx1" 81/4 "ODx1" Belt Size/Number BX51 BX51 Sheave Adjustment * * CtoC/Motor Mount Adj * I In * I Out * * I In * I Out * Remarks: Form #1.5.5 8 • O 0 EAGLE TEST & BALANCE COMPANY Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -A5 EXISTING AIR MOVING EQUIPMENT DATA FAN RTU -A5 Actual Equipment Location ROOF Total CFM -Fan Area Served STORAGE /RETAIL 71/4 "ODx1" Equipment Manufacturer LENNOX 3000 Model GCS24-953-200-1G AX46 Serial Number 5695L03582 2545 Motor Sheave & Shaft Specified Actual Specified Actual Total CFM -Fan 3000 2985 71/4 "ODx1" Total CFM - Outlet 3000 2985 AX46 R/A CFM 2570 2545 Sheave Adjustment O/A CFM 430/1060 440 CtoC/Motor Mount Adj Tot/Ex Static Pressure .6 .55 1 In 1 Out Inlet Pressure * -.36 Discharge Pressure * .19 Fan RPM * 940 Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg GE GE 71/4 "ODx1" Motor HP/BHP 2 2 AX46 Phase/Hz 3 3 Sheave Adjustment Voltage 460 482/484/484 CtoC/Motor Mount Adj Amperage 31 2.9/2.8/2.8 1 In 1 Out Motor RPM 1725 1740 Motor Sery Fac/Frame # 1.15 1.15 Starter Location/Size * * O.L. Heater Size/Rating * * Motor Sheave & Shaft 1VL44x7/8" Fan Sheave & Shaft 71/4 "ODx1" Belt Size/Number AX46 Sheave Adjustment * CtoC/Motor Mount Adj * I In * I Out * 1 In 1 Out Remarks: Form #1.5.5 9 • 0 0 EAGLE TEST & BALANCE COMPANY Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -1, RTU -2 EXISTING AIR MOVING EQUIPMENT DATA FAN RTU -1 RTU -2 Equipment Location ROOF ROOF Area Served RETAIL RETAIL Equipment Manufacturer TRANE TRANE Model YCD360A4LA1A2DC1 YCD360A4LA1A2DC1 Serial Number J95L91908 J95L91907 Motor Sheave & Shaft Specified Actual Specified Actual Total CFM -Fan 10500 10733 10500 10827 Total CFM - Outlet 10500 10733 10500 10827 R/A CFM 9540/8120 9768 9540/8120 9867 0/A CFM 960/2380 965 960/2380 960 Tot/Ex Static Pressure .6 .56 .6 .57 Inlet Pressure * -.33 * -.32 Discharge Pressure * .23 * .25 Fan RPM * 710 * 705 Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg MARATHON MARATHON MARATHON MARATHON Motor HP/BHP 10 10 10 10 Phase/Hz 3 3 3 3 Voltage 460 480/480/481 460 481/480/480 Amperage 13.3 12.6/12/72.4 13.3 12.9/13.1/12.0 Motor RPM 1745 1755 1745 1750 Motor Sery Fac/Frame # 1.15 1.15 1.15 1.15 Starter Location/Size * * * * O.L. Heater Size/Rating * * * * Motor Sheave & Shaft 6.5 "ODx13/8" 6.5 "ODx13/8" Fan Sheave & Shaft 15 3/4 "ODx1 7/16" 15 3/4 "ODx1 7/16" Belt Size/Number BX103 BX103 Sheave Adjustment * * CtoC/Motor Mount Adj * I In * I Out * * I In * I Out * Remarks: Form #1.5.5 10 • • • EAGLE TEST & BALANCE COMPANY Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -3, RTU-4 EXISTING AIR MOVING EQUIPMENT DATA FAN RTU -3 RTU-4 Equipment Location ROOF ROOF Area Served RETAIL RETAIL Equipment Manufacturer TRANE TRANE Model YCD300B4LODC YCD300B4LODC Serial Number K24100120D K26100707D Motor Sheave & Shaft Specified Actual Specified Actual Total CFM -Fan 9000 9079 9000 8676 Total CFM - Outlet 9000 9079 9000 8676 R/A CFM 8150/6900 8219 8150/6900 7806 0/A CFM 850/2100 860 850/2100 870 Tot/Ex Static Pressure .6 .56 .6 .62 Inlet Pressure * -.34 * -.38 Discharge Pressure * .22 * .24 Fan RPM * 925 * 915 Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg MARATHON MARATHON MARATHON MARATHON Motor HP /BHP 7.5 7.5 7.5 7.5 Phase/Hz 3 3 3 3 Voltage 460 482/481/481 460 480 /481/481 Amperage 11.8 7.2/7.3/71 11.8 6.2/6.2/6.1 Motor RPM 3450 3410 3450 3465 Motor Sery Fac/Frame # 1.15 115 1.15 1.15 Starter Location /Size * * * * O.L. Heater Size/Rating * * * * Motor Sheave & Shaft VP56x1 1/8" VP56x1 1/8" Fan Sheave & Shaft 18 5/8 "ODx13/16" 18 5/8 "ODx13/16" Belt Size/Number BX81 BX81 Sheave Adjustment * * CtoC/Motor Mount Adj * 1 In * 1 Out * * 'In * 1 Out * Remarks: Form #1.5.5 11 0 • EAGLE TEST & BALANCE COMPANY Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -8, RTU -9 NEW AIR MOVING EQUIPMENT DATA FAN RTU -8 RTU -9 Equipment Location ROOF ROOF Area Served ENTRY ADMIN OFFICES Equipment Manufacturer LENNOX LENNOX Model LGH060H4EMIG LGH036H4ESG Serial Number 5610E04529 3610E04548 Motor Sheave & Shaft Specified Actual Specified Actual Total CFM -Fan 1900 2260 1100 1205 Total CFM- Outlet 2250 2260 1200 1205 RIA CFM 2120 2125 1015 1010 O/A CFM 130 135 185 195 Tot/Ex Static Pressure .7 .59 .6 .57 Inlet Pressure * -.36 * -.36 Discharge Pressure * .23 * .21 Fan RPM * HIGH * HIGH Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg GE ECM GE ECM GE ECM GE ECM Motor HP /BHP 1 1 .5 .5 Phase/Hz 1 1 1 1 Voltage 208 208 208 208 Amperage 3.7 3.1 2.2 1.1 Motor RPM * 2 SPEED * 2 SPEED Motor Sery Fac/Frame # * * * * Starter Location /Size * * * * O.L. Heater Size/Rating * * * * Motor Sheave & Shaft DIRECT DRIVE DIRECT DRIVE Fan Sheave & Shaft DIRECT DRIVE DIRECT DRIVE Belt Size/Number DIRECT DRIVE DIRECT DRIVE Sheave Adjustment * * CtoC/Motor Mount Adj * I In * I Out * * I In * I Out * Remarks: Form #1.5.5 12 0 • 0 EAGLE TEST & BALANCE COMPANY ANL Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: RTU -10, RTU 11 NEW AIR MOVING EQUIPMENT DATA FAN RTU -10 RTU -11 Equipment Location ROOF ROOF Area Served BACK STORAGE AREA BREAKROOM, RESTROOMS Equipment Manufacturer LENNOX LENNOX Model LGH092H4BS1G LGH048H4ES1G Serial Number 5610E04282 5610E04571 Motor Sheave & Shaft Specified Actual Specified Actual Total CFM -Fan 3000 3022 1600 1670 Total CFM- Outlet 3000 3022 1600 1770 R/A CFM 2820 2837 1400 1440 O/A CFM 180 185 220 230 Tot/Ex Static Pressure .5 .48 .65 .63 Inlet Pressure * -.29 * -.37 Discharge Pressure * .19 * .26 Fan RPM * 885 * HIGH Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg BALDOR BALDOR GE ECM GE ECM Motor HP/BHP 2 2 .75 .75 Phase/Hz 3 3 1 1 Voltage 460 480/480/482 208 208 Amperage 3.1 2.62.5/2.3 2.9 1.8 Motor RPM 1725 1730 * 2 SPEED Motor Sery Fac/Frame # 1.15 1.15 * * Starter Location/Size * * * * O.L. Heater Size/Rating * * * * Motor Sheave & Shaft 1VP34x7/8" DIRECT DRIVE Fan Sheave & Shaft 5 3/4 "ODx1" DIRECT DRIVE Belt Size/Number AX54 DIRECT DRIVE Sheave Adjustment * * CtoC/Motor Mount Adj * I In * I Out * * I In * I Out * Remarks: Form #1.5.5 13 • • EAGLE TEST & BALANCE COMPANY MIL Project Name: Babies R US Project #: ETB -10 -1469 Date: 10/5/10 System: EF -1 FAN DATA FAN EF -1 Actual Equipment Location ROOF Total CFM -Fan Area Served RESTROOMS DK40x3/4" Equipment Manufacturer GREENHECK 1100 Model GB- 131 -4-X 3L200 Serial Number 12184328 1008 .36 Motor Sheave & Shaft Specified Actual Specified Actual Total CFM -Fan 1100 1080 DK40x3/4" Total CFM -Air Dist 1100 1080 3L200 Tot/Ex Static Pressure .33 .36 Sheave Adjustment Inlet Pressure * -.32 CtoC/Motor Mount Adj Discharge Pressure * .04 I In 1 Out Fan RPM * 1155 Motor Sheave & Shaft Specified Actual Specified Actual Motor Mfg GREENHECK GREENHECK DK40x3/4" Motor HP/BHP 1/4 1/4 3L200 Phase/Hz 1 1 Sheave Adjustment Voltage 115 121 CtoC/Motor Mount Adj Amperage 4.6 3.8 I In 1 Out Motor RPM 1725 1740 Motor Sery Fac/Frame # 1.35 1.35 Starter Location/Size * * O.L. Heater Size/Rating * * Motor Sheave & Shaft 1VP34x1/2" Fan Sheave & Shaft DK40x3/4" Belt Size/Number 3L200 Sheave Adjustment * CtoC/Motor Mount Adj * [ In * I Out * I In 1 Out Remarks: Form #1.5.7 14 is a PE if PY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -033 DATE: 03 -11 -10 PROJECT NAME: TOYS R US / BABIES R US SITE ADDRESS: 17501 SOUTHCENTER PY SUITE 300 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: i iHOP-V° Building ivision Public Works ❑ A-m. ir.0-10 Fire Prevention Structural n Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 03-16 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04 -13 -10 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page 0 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Sun Glow Inc UBI No. 600578701 Phone 5032537789 Status Active Address 2428 Se 105Th License No. SUNGLI'088RB Suite /Apt. License Type Construction Contractor City Portland Effective Date 12/2/1992 State Or Expiration Date 2/14/2012 Zip 97216 Suspend Date County Out Of State Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date Golobay, Edwin President 12/02/1992 Bond Amount Golobay, Sharon A Vice President 12/02/1992 70185629 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 70185629 02/01/2007 Until Cancelled 19.28.041 RCW ELECTRICAL CITATION $12,000.00 02/06/2007 3 DEVELOPERS SURETY & INDEM CO 124274C 12/01/2001 Until Cancelled 12/21/2006 ECAML00776 512,000.00 02/04 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 10 OHIO CASUALTY INS CO 53583105 02/01/2007 02/01/2011 19.28.041 RCW ELECTRICAL CITATION $1,000,000.00 01/19/2010 9 NORTHERN INS CO OF NY SCP39760500 02/01/2005 02/01/2007 $500.00 ECAML00776 $1,000,000.0001 /23/2006 8 ASSURANCE CO OF AMERICA SCP39760500 02/01/2004 02/01/2005 $1,000,000.00 01/20/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EDISH00296 2/18/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EDISH00297 2/18/2009 19.28.041 RCW ELECTRICAL CITATION Satisfied $500.00 ECAML00777 9/9/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $500.00 ECAML00776 9/9/2009 19.28.041 RCW ELECTRICAL CITATION Satisfied 5750.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 06/15/2010 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049067 Permit Number: M10 -033 Address: 17501 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 03/11/2010 Applicant: TOYS R US / BABIES R US Issue Date: Receipt No.: R10 -01056 Initials: User ID: JEM 1165 Payment Amount: $1,044.05 Payment Date: 06/15/2010 11:40 AM Balance: $0.00 Payee: RODNEY G SHEAFFER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 010545 ACCOUNT ITEM LIST: Description 1,044.05 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 1,044.05 Total: $1,044.05 PAYMENT RECEIVED doc: Receipt -06 Printed: 06 -15 -2010 5 KEYED NOTES (APPLICABLE TO DRAWINGS M101 THRU M301) ( ( ( ( 2 3 4 5 6 7 10 11 12 PROVIDE TYPE "M" OR "DWV" COPPER CONDENSATE DRAIN FROM UNIT TO ROOF ON LOW ROOF (DOWNHILL) SIDE OF UNIT. EXTERNAL 4" DEEP P -TRAP REQUIRED ONLY IF EQUIPMENT IS NOT SUPPLIED W /BUILT IN TRAP SYSTEM. REFER RTU CONDENSATE DRAIN PIPING DETAIL AND ROOF PIPING SUPPORT DETAIL ON DRAWING M101. VERIFY WITH RTU MFR. CAP ALL UNUSED CONDENSATE DRAIN FITTINGS. ANCHOR THE DISCHARGE END OF CONDENSATE DRAIN PIPING TO MIN. 4" X 4 "X 24" LONG PRESSURE TREATED WOOD BLOCKING WITH 1" GALV. STRAP ANCHOR AND TWO (2) #10 X 1 -1/2" SHEET METAL SCREWS. CENTER BLOCKING BELOW PIPING. DO NOT ATTACH WOOD BLOCKING TO ROOF. TYP. AT ALL RTU'S. SECURELY MOUNT CU -1 ON ROOF TO EQUIPMENT SUPPORT RAILS MANUFACTURED BY ROOF PRODUCTS INC. MOD. #RPES -1 FOR BUILT -UP ROOF OR RPES -3 FOR MEMBRANE ROOF, MECHANICALLY FASTEN TO ROOF STRUCTURE. FURNISH AND INSTALL REFRIGERATION PIPING AS RECOMMENDED BY THE MFR. AND CONTRACT DOCUMENTS. HAC SHALL PROVIDE NEW NATURAL GAS CONNECTION TO NEW RTU. ROUTE PIPE UP FROM BELOW ROOF DECK THRU APPROVED PIPE CURB, PROVIDE FULL SIZE DIRT LEG WITH GAS COCK AND UNION AT ALL GAS FIRED EQUIPMENT. TYPICAL AT ALL NEW RTU'S. MAINTAIN 3" MINIMUM CLEARANCE FOR CLEANING OF DIRT LEG. NEW GAS PIPING SHALL BE INSTALLED BELOW ROOF DECK EXCEPT WHERE NOTED. NEW PIPE SHALL BE HUNG WITHIN 12" OF ROOF DECK, SEISMIC CONDITIONS. ROUTE AS HIGH AS POSSIBLE WITH ALLOWANCE FOR SLOPE AS REQUIRED. WALL MOUNT AIR HANDLING UNITS SHALL BE PROVIDED WITH INTEGRAL CONDENSATE PUMPS. THE PUMP DISCHARGE SHALL SLOPE BACK TO SERVICE SINK IN THE JANITOR'S CLOSET. THE DRAIN LINE SHALL SLOPE AT 1 /4 " /FT. TOWARD THE SINK. THE CONDENSATE LINE SHALL TERMINATE 2" ABOVE THE FLOOD PLAIN OF THE SINK (2" AIR GAP). FLEXIBLE DUCTS SHALL BE INSTALLED TO PROVIDE SWEEPING CONFIGURATIONS WITH NOT LESS THAN MFR'S. RECOMMENDED BEND RADIUS, WITHOUT UNDUE RESTRICTIONS, BUT NOT CREATING UNNECESSARY SAGS OR CURVES, FLAT BANDING MATERIAL NOT LESS THAN 1 -1/2" WIDE SHALL BE USED TO SUSPEND FLEXIBLE DUCTS. DUCTING FURNISHED WITH FACTORY INSTALLED GROMMETS SHALL BE SUSPENDED BY WIRES ATTACHED TO GROMMETS. FLEX DUCT SHALL EXCEED 5' -0 ". PREFERRED FOR ONLY VERTICAL DROP TO DIFFUSER /GRILLE. PROVIDE DUCT DROPS FROM UNIT FULL SIZE OF UNIT CURB OPENINGS. TRANSITION AS REQUIRED TO DUCT SIZES SHOWN ON PLAN. TRANSITIONS SHALL BE MADE IN A CCORDANCE WITH SMACNA STANDARDS. VERIFY RTU CURB OPENING SIZES AND CONFIGURATION WITH RTU MFR. EXISTING GAS METER AND REGULATOR TO BE REUSED. EXISTING CONNECTED LOAD = 1200 MBH, DELIVERY PRESSURE = 2 PSIG (FIELD VERIFY). THIS METER SHALL BE USED TO SERVICE TO OTHER SIDE OF BUILDING. SECOND GAS METER EXISTING CONNECTED LOAD = 1630 MBH AT LOW PRESSURE (14 "W.C.). THIS METER'S NEW CONNECTED LOAD SHALL EQUAL = 1945 MBH. CONNCOORDINATE WITH GAS UTILITY CO. FOR METER RESET AND CONFIGURATION CHANGES AS REQUIRED. THIS CONTRACTOR SHALL COORDINATE WITH THE UTILITY FOR THE REMOVAL OR ABANDONMENT OF THE SECOND GAS METER. REFER TO DETAIL ON DRAWING M101 AND SPECIFICATION ON DWG. M301 FOR SUPPLY AND RETURN AIR DUCT CONFIGURATION FOR SALES AND PRESALES RTUS (SERVING PLENUM DIFFUSERS). THE MECHANICAL CONTRACTOR SHALL INSTALL OWNER FURNISHED PLENUM DIFFUSER AND PROVIDE REQUIRED SHEETMETAL TRANSITIONS FROM PLENUM DIFFUSER TO CONNECTIONS OF RTU. NOTE THAT TOP OF DIFFUSER SHALL BE BELOW ADJACET ROOF JOISTS AND THE SHEETMETAL TRANSITION SHALL BE ECCENTRIC (PLENUM DIFFUSER SHALL OFFSET TOWARD RETURN OPENING (PARTIALLY BLOCK VIEW OF RA OPENING FROM VIEW BELOW UNIT.) REMOVE EXISTING SUPPLY PLENUM AND SUPPLY GRILLES AND INSTALL NEW PLENUM DIFFUSER. PROVIDE NEW DUCT TRANSITIONS. EXISTING RETURN AIR DUCT /PLENUM SHALL REMAIN. REMOVE ALL EXISTING SUPPLY DUCTWORK EXCEPT FOR DUCT DROPS FROM EXISTING RTU. INSTALL NEW PLENUM DIFFUSER PER KEYNOTE #9.. PROVIDE NEW DUCT TRANSITIONS TO NEW PLENUM DIFFUSER. EXISTING RETURN AIR DUCT /PLENUM SHALL REMAIN. EXISTING SUPPLY AND RETURN DUCTWORK FROM EXISTING RTU SHALL BE REMOVED EXCEPT FOR DUCT DROPS FROM UNITS. THIS CONTRACTOR SHALL PROVIDE NEW SUPPLY AND RETURN DUCTWORK AS SHOWN ON PLAN. NOTE: CONTRACTORS SHALL REFER TO THE FIXTURING PLAN, DRAWING RF1, FOR COORDINATION OF ALL PIPING, EQUIPMENT, DUCTS, VALVING, AND SERVICE RISERS WITH THE OWNER'S STORE FIXTURING. ALL SYSTEMS SHALL BE ROUTED AND /OR LOCATED AS REQUIRED TO AVOID INTERFERENCE WITH THE STORE FIXTURES, SHELVING, AND RACKING INCLUDING THE FUNCTIONAL USE OF SAME. INSTALLATIONS MADE WITHOUT REGARD TO STORE FIXTURING SHALL BE CORRECTED AT NO ADDITIONAL COST TO THE OWNER, SPECIAL CONSIDERATION SHALL BE GIVEN TO THE ESTHETIC INTENT OF THE FRONT GRAPHICS WALL OF THE STORE AND TO THE STORAGE AND MATERIALS HANDLING ASPECTS OF THE PRE -SALES AND RECEIVING DOCK AREAS. GENERAL NOTES: 1. SUPPLY AND RETURN AIR DUCTWORK SHALL HAVE 1" THICK INTERNAL FIBERGLASS DUCT LINER EQUIVALENT TO CERTAINTEED (GCS) OR OWENS CORNING. DUCT SIZES SHOWN ON DRAWING ARE INSIDE CLEAR SIZES, ALLOWANCE FOR INTERNAL DUCT LINER HAS NOT BEEN MADE WHERE SPECIFIED. ROUND DUCT BRANCHES SHALL HAVE 1" BLANKET INSULATION. INTERNALLY LINED SPIRAL DUCT SHALL BE USED WHERE VISIBLE FROM SALES FLOOR. 2. RTU'S ARE CONTROLLED BY OWNER FURNISHED SENSORS. ELECTRICAL CONTRACTOR SHALL INSTALL RTU SENSORS, REFER ELECTRICAL DWGS. FOR LOCATIONS. 3 PROVIDE TURNING VANES AT ALL DUCT ELBOWS AND TEES. 4 REFER TO DIFFUSER CONNECTION DETAIL ON DWG. M201. 5. COORDINATE THE INSTALLATION OF ALL RTU'S WITH STRUCTURAL DRAWINGS. RTU CURB LOCATIONS ARE DIMENSIONED ON THE STRUCTURAL FRAMING PLAN. THE HAC SHALL PROVIDE RTU SHOP DRAWINGS TO THE STEEL FABRICATOR FOR COORDINATION. 6. REFER TO DRAWING P101 FOR HVAC DEMOLITION NOTES. HVAC DDC CONTROL NOTES: 1. ALL RTU'S ARE OWNER FURNISHED WITH LENNOX BACNET INTERFACE BOARDS. 2. THE HVAC DDC CONTROLS ARE BY AUTOMATED LOGIC, PROVIDED BY OWNER, 3. ALL WIRING /INSTALLATION OF HVAC AND LIGHTING CONTROLS SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. 4. FOR TEMPERATURE SENSOR LOCATIONS, EMS MAIN PANEL LOCATIONS, ETC., REFER TO DRAWINGS E101 AND EMS -1. 5. THE MECHANICAL CONTRACTOR AND AIR BALANCER SHALL COORDINATE UNIT STARTUP AND OPERATION WITH E.C. AUTOMATED LOGIC NATIONAL ACCOUNT REPRESENTIVE. REFER TO DRAWING EMS -1 FOR ADDITIONAL INFORMATION. ADAPTER (AS REQ'D.) OWNER FURNISHED RTU r /— 90 DEG ELL OWNER FURNISHED ROOF CURB ADAPTER �illll.■ NOTE: EXTERNAL P -TRAP REQ'D. ONLY IF RTU IS NOT SUPPLIED WITH A BUILT -IN TRAP SYSTEM. VERIFY WITH RTU MFR. J� TEE ROOF SURFACE —\ 4" MIN. TRAP SEAL PLUG MIPT - FOR CLEANOUT (CO) AND WINTERIZATION DRAIN RTU CONDENSATE DRAIN DETAIL M101 SCALE = NTS 6 UNIT BASE NAILER STRIP CURB SHIM AS REQUIRED TO LEVEL UNIT RTU FRAMING, REFER TO ARCH. AND STRUCT PLANS NEW RTU TO BE ANCHORED TO ROOF CURB L: RIGID INSULATION & CANTS BY G.C.C. rr ROOF DECK SEISMIC CURB TO BE ANCHORED TO STRUCTURAL STEEL NOTE: NEW CURBS SHALL BE RATED FOR SEISMIC ZONE. NEW CURBS WILL BE PROVIDED BY OWNER, THRU LENNOX, INC. THE INSTALLING CONTRACTOR SHALL SECURE THE CURB AND RTU PER LOCAL CODE REQUIREMENTS AND PER MANUFACTURER'S INSTRUCTIONS. NEW SEISMIC RTU CURB DETAIL M1 01 SCALE = NTS ROOF CURB (FURNISHED BY OWNER) CANT STRIP ROOF INSULATION TOP OF ROOF DECK FULL SIZE R.A. DUCT RETURN AIR GRILLE 8 PROVIDE NEW 3"G MAIN FOR PORTION OF STORE CURRENTLY SERVED BY EXISTING GAS METER TO BE REMOVED. ROUTE NEW LINE WITHIN 12" OF ROOF DECK EXISTING GAS METER TO BE REUSED OFFSET EXISTING 4 "G LINE INTO BUILDING TO LINEUP WITH NEW WETWALL CHASE BETWEEN TOILET ROOMS. (FIELD VERIFY EXISTING) CONNECT NEW /OFFSET 4" GAS LINE TO EXISTING UP AT ROOF DECK. NEW SUPPLY PLENUM MH -18' -0 "AFF SEE DETAIL THIS SHEET EXISTING RA- PLENUM TO REMAIN EX: TO REMAIN 25 —TON .. EXISTING RA PLENUM TO REMAIN CONTR. TO RETAIN ELBOWED RA PLENUM DUCTWORK WHERE EXISTING. SHORT RUN APPLIES TO RTU -12 ONLY. DISTANCE SHALL NOT IMPEDE AIRFLOW ADJUSTABLE DRUM LOUVER SUPPLY AIR GRILLE (4 SIDES) r 1 WAN 9 SUPPLY PLENUM MH -17' -0 "AFF 2 -WAY OPPOSITE ONLY SEE DETAIL THIS SHEET I NEW SUPPLY PLENUM MH -18' -0 "AFF SEE DETAILTHIS SHEET .:.; EXIS-TING RA PLENUM TO REMAIN HVAC TEMP :::SENSORS. CO2 SENSORS ARE SHOW ON. DWG __E1.04... AND :EMS1 PROVIDED BY OWNER, WIRED BY E.C:. EX. TO REMAIN 300 MBH LOW PRESSURE GAS LINES TO REMAIN UNLESS NOTED OTHERWISE (TYPICAL) —w NEW 2 "G ROUTE SA DUCT AT BOTTOM OF JOISTS (APPROX. 18' -0 "AFF) S -3 14x8 250 CFM ........._22 "x 18 "__. • 6 6 S -3 24X12 1000 CFM S -3 14x8 250 CFM I� I' ,a: f REMAIN , 7:5 :'TON 22 "x18" 14 "x14" NEW PRV STATION, REFER TO DETAIL THIS SHEET. OUTLET CAPACITY = 1645 MBH @ 14 "W.C. THIS CONTRACTOR TO REMOVE EXISTING NATURAL GAS UP TO CONNECTION OF NEW LINE SERVICE FROM THE OTHER EXISTING GAS METER TO REMAIN EXISTING GAS METER WILL BE DECOMMISSIONED. COORDINATE REMOVAL• WITH GAS UTILITY (8) EXISTING NATURAL GAS PIPING TO REMAIN (TYPICAL) NEW 22x18 RA DUCT, MOUNT AS HIGH AS POSSIBLE 12" BELOW ROOF DECK S -8 24x12 1000 CFM NEW..SUPPLY PLENUM MH= i 8'=0 "AFF SEE.DETAIL THIS SHEET (2) S -3 18x8 500 CFM EA. EX. TO REMAIN =TONS EXISTING RA PLENUM TO REMAIN ::':::::::' .............. ............................... LOW PRESSURE GAS LINES TO REMAIN UNLESS. NOTED, OTHERWISE(TYPICAL) S -7` 24x12 1000 CFM 14 "x14" S -3 24x12 ;1000 CFM NEW SUPPLY h, PLENUM:;.:.::.:: :. :<I_ MH =9 -0 "AFF I... SEE DETAIL :THIS,SHEET' NEW SUPPLY PLENUM MH -16' -6 "AFF SEE DETAIL THIS SHEET S -3 24x12 1000 CFM:::::: IBM EXISTING RA PLENUM TO REMAIN EX: TO REMAIN 25 -TON ABANDONS' D IN PLACE.. 2 -TON NEW SUPPLY PLE ::::::...::::..: :. • i MH,19'- 0 "AF.F......:.: SEE DETAIL THIS SHEET..:.. ................. 18 "x18" EX. TO REMAIN 10 -TON EXISTING RA DUCT /PLENUM TO REMAIN (2) S -3 18x8 500 CFM EA. MOUNT SUPPLY DUCTWORK AT 18' -0 "AFF FULL SIZE S.A. DUCT (REUSE EXISTING WHERE APPLICABLE) PERFORATED STEEL N_AIR DEFLECTOR S.A. DUCT TRANSITION SUPPLY DIFFUSER BOX NOTES PLENUM DIFFUSER SHALL BE FURNISHED BY OWNER THROUGH LENNOX. SHEET METAL, INCLUDING TRANSITIONS TO PLENUM DIFFUSER SHALL BE BY THE MECHANICAL CONTRACTOR. INSTALLATION OF ALL ITEMS SHALL BE BY THE M.C. INSTALLATION OF DUCTS, PLENUM DIFFUSER, & GRILLES IS TYPICAL FOR SALES FLOOR RTU'S. DESIGN INTENT FOR ALL EXISTING SALES FLOOR RTU'S IS TO REMOVE ALL SUPPLY DUCTWORK WITH THE EXCEPTION OF THE DUCT DROPS FROM RTU. INSTALL NEW PLENUM DIFFUSER AS INDICATED. RETURN AIR PLENUM & GRILLES TO REMAIN. (FIELD VERIFY) REFER RTU PLENUM DIFFUSER SPECIFICATIONS ON SHEET M301 FOR FURTHER REQUIREMENTS AND CLARIFICATION. HAC SHALL PROVIDE AUXILIARY STEEL CHANNELS, ANGLES, AND /OR UNI -STRUT AS REQUIRED TO SECURELY SUPPORT THE S.A. DUCT, DIFFUSER BOX, AND GRILLES FROM THE ROOF STRUCTURE. PROVIDE VIBRATION ISOLATION FOR SUPPORT FRAMING. THE TOP OF THE SUPPLY DIFFUSER BOX/GRILLES SHALL BE MOUNTED BELOW ADJACENT STRUCTURAL STEEL JOISTS. TO PROVIDE CLEAR AIR THROW. M1.01 0 `RTU CAP GAS LINE ABOVE ROOF: Ex. 'TO :: >__ REMAIN...,,...... 10 -TON EXISTING RA PLENUM TO REMAIN NEW 1 "G • NEW 5 -TON 24x12 1000 CFM 121 EX. TO REMAIN 10 -TON EXISTING RA DUCT /PLENUM TO REMAIN (2) S -3 18x8 500 CFM EA. •—•• NEW 3 -TON PLENUM DIFFUSER DETAIL (4SALES/PRESALES M101 SCALE = NTS MAIN HVAC FLOOR PLAN SCALE = 1 /1 6" = 1' -0" EXISTING RA PLENUM TO REMAIN (TYPICAL) OWNER FUNISHED PLENUM DIFFUSER PLAN NORTH REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. MC TO PROVIDE SA ECCENTRIC DUCT TRANSITION TO OWNER FURNISHED PLENUM DIFFUSER, REFER TO DETAIL THIS SHEET. 1 SALES FLOOR RTU SECTION M101 SCALE = 1 /8" = 1' -0" 2 1 "G GAS PRESSURE REDUCING VALVE, INSTALL VALVES WITH VENT DOWN AS REQUIRED BY MFG REDUCER (TYP.) UNION (TYP.) — >HSH SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical erElectrical [Plumbing Was Piping City of Tukwila BUILDING DIVISION FILE COPY Permit No. M t o — 0 3 3 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy an I, • ditions is acknowledged: // e_h /0 By Date: City Of Tukwila BUILDING DIVISION TURN VENT DOWN REGULATOR SHALL BE VENTED TO THE OUTSIDE, UP THRU ROOF. 1/4" F.P.T. AND PLUG TEST PORT N.C. GAS COCK REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 6 2010 �V r City of Tukwi% BUILDING DIVISION RECEIVED MAR 112010 El PERMIT CENTER DIRECTION OF FLOW M GAS PRESSURE REDUCING STATION M101 / SCALE = 12" = 1-0" CONSTR. DOC & REVISIONS NO. DATE DESCRIPTION 02/26/10 ISSUED FOR 90% LL REVIEW 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 BID DATE: DRAWN BY: PROTOTYPE 03/09/2010 BJP DESIGNATION: PROJECT NO.: 55252805 CHECKED BY: RAF SSBS 58K PROTOTYPE architecture engineering, P.C. 18114 Mile Rd NE Grand Rapids, Mi 49525 www.progressiveae.com STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION T U KW I LA, WA DRAWING TITLE MECHANICAL FLOOR PLAN SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. M1O1 AR, ENTRY VESTIBULE 102 41 ENTRY HVAC SECTION M201 / SCALE = 1/4" =11-0" M201 ENTRY, VESTIBULE 102 10"o Roo 25' - 0" KRTU) 8 NEW FRONT RIGHT ISOMETRIC SCALE = 2� FRONT CENTER ISOMETRIC .M SCALE = R -7 R -7 24x24,12 "DIA. 1060 CFM r ?'� - --,- 1 1 1 1 1 L_s 24x24,12 "DIA. 1060 CFM I ( r ) I I' / 1 I --' I s`' --' 14 "x14" / S -4\ S -4 4- SLOT,10 "DIA. ` .4- SLOT,10 "DIA. 375 CFM 375 CFM 20 "x16" 26 "x12" 14 "x14" EXIT VESTIBULE 103 10" o S -4 l 4- SLOT,10 "DIA. 375 CFM \. S -4 4- SLOT,10 "DIA. 375 CFM 3 ENLARGED ENTRY HVAC PLAN M201 S -4 \\ 4- SLOT,10 "DIA. 375 CFM SCALE = 1/4" = 1' -0" 6 • '\ S -4 '4- SLOT,10 "DIA. 375 CFM . / -- 6? EVAPORATOR UNIT (AHU), PROVIDED BY HVAC, WALL MOUNT WITH BRACKETS AS INDICATED ON PLANS SUCTION TRAP ROOF MOUNTED CONDENSING UNIT (CU) EQUIPMENT RAILS SPANNING JOISTS, BY HAC PATE CURB, BY M.C., FOR ROOF PENETRATION OF REFRIGERATION PIPING AND POWER CONDUITS, SEE SCHEDULE AND MFG INFORMATION FOR LINESET SIZE CONDENSATE DRAIN, EXTEND AND TERMINATE WITH AIR GAP IN LOCATION INDICATED ON PLANS THERMOSTAT /CONTROLLER FURNISHED WITH UNIT, INSTALLED BY HAC � 5 � SPLIT SYSTEM AC UNIT SCHEMATIC SCALE = 12" = 1' -0" 10 "x14" 14 "x14" 11 "x29" 10 "x14" 10 "x14" SALES AREA 101 SPRINKLER RISER 110 MANAGER'S .. ___._OFFICE. _.___...______ 111 .. ............................... COUNT ROOM,..._..._. 112 PROCESSING ROOM X10 "x14" PROCESSING ROOM 106 14 "x14" R -7 8 "DIA. 130 CFM SALES AREA OFFICE AREA HVAC SECTION SCALE = 1/4" = 1' -0" 101 MANAGER'S .. OFFICE _ COUNT.,_ ROOM i 111 14 "x10" 8 "o 8 "a 112 S -1 6" 100 CFM S -2 6" 130 CFM SALES AREA 101 S -3 8x6 100 CFM S -1 6" 130 CFM. - -.... 14 "x10" 14 "x10" 14 "x14" 8" 14 "x10" 14 "x10" R -7 8 "DIA. 200 CFM ROCESSING 8 "o OOM-- • —� TYPICAL R -8 18x8 440 CFM S -3 18x8- 440 CFM 106 \..�a... S -1 8" 200 CFM RTU MFG. REFRIG. LINESET, ROUTE DOWN FROM ROOF THRU APPROVED PIPE CURB EQUIPMENT ROOM 107 ENLARGED OFFICE AREA HVAC PLAN M201 SCALE = 1/4" = 1' -0" PRE -SALES 119 l ,I NEW 1 L i REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 6 2010 City:of Tukwila „UILDING DIVISION P1I003 r. � i ,._.) RECEIVED MAR 112010 PER MT CENTER CONSTR. DOC & REVISIONS NO. DATE DESCRIPTION 02/26/10 ISSUED FOR 90% LL REVIEW 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 BID DATE: 03/09/2010 DRAWN BY: BJP PROJECT NO.: 55252805 CHECKED BY: RAF PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE architecture engineering, P.C. 18114 Mile Rd NE Grand. Rapids, Mi 49525 www.progressiveae.com STORE SUPPORT CENTER ONE GEOFFREY WAY W AYN E, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION T U KW I LA, WA ENLARGED HVAC PLANS & SECTIONS SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. M201 OA BREAK ROOM AREA ISOMETRIC M202 SCALE _ M202 SCALE = BREAKROOM HVAC SECTION SCALE = 1/4" = 1' -0" GENERAL NOTE: ALL BRANCH DUCTS TO SA, RA OR EA DUCTS SHALL HAVE BALANCING DAMPERS, UNLESS GRILLE HAS A REGISTER. AIR FLOW 1► RECTANGULAR MAIN DUCT 45° BALANCING DAMPER W /LOCKING QUADRANT TAKEOFF - RECTANGULAR MAIN ROUND BRANCH R = 1.5 W ELBOWS - RADIUSED RECTANGULAR RECTANGULAR TO ROUND TRANSITION TAKE -OFF AIRFOIL SHAPED TURNING VANES SQUARE TURN RECTANGULAR 2' -0" MIN. IF SINGLE BLADE DAMPERS W BALANCING DAMPERS WHERE SHOWN ON PLANS TEES - RECTANGULAR 2 LOW PRESSURE DUCT FITTING MEN'S ROOM 122 6 M202 M202 SCALE = 12" = 1' -0" �— EXHAUST FAN WITH BIRD SCREEN SUPPLIED AND INSTALLED BY HAC GRAVITY - BACKDRAFT DAMPER BY FAN MFG. INSULATION ROOF MEMBRANE ROOF DECK ROOF ANGLE STEEL ANGLE FRAME SPANNING BETWEEN ROOF JOIST, BY OTHERS ATTACH DUCT TO FRAME BY HAC EXHAUST FAN DETAIL SCALE = 12" =1'-0" BALANCING DAMPER AIR FLOW 45 DEGREE TAP - IN FITTING WITH DAMPER. TYPICAL DIFFUSER FLEX, MAXIMUM LENGTH = 5' -0" CEILING TYPICAL DIFFUSER (3\\ DIFFUSSER CONNECTION DETAIL M202 / SCALE = 1" = 1' -0" • 3 \ 1 S -3 18x8 390 CFM 12 "x12" S-2 8 "DIA. 180 CFM — . 12 "x12" 8"o E -5 12x12' 410 CFM E -5 12x12 410 CFM 14 "x6" R -7 10 "DIA.- 290 CFM I RTU 11 NEW 18 "x12' R -7 12 "DIA. 500 CFM PRE -SALES 119 R -8- / -18x8 390 CFM 18 "x8" 18 "x12" I 1 1 t 1 12'x8" 14 "x12" 20 "x12" 16 "x10" ANITOR' S CLOSET HALL 113 E-6 8x8 8x8 210 CFM 14 "x6" : wex ::>M:;:J),bxv:r..:o.>;tw:oxa• •`E -6 6x6 70 CFM 10 "e 16 "x10" 10 "x10" m A kr 4 f3�6 -�w'r3 R -7 10"D IA. 220 CFM TRAINING ROOM 108 12 "x6" 10 "e 10"o 14 "x12' Y.I 12 "x6" 10 "x6" 16 "x10 "; S -1 8 "DIA. 130 CFM —® 8"o \ S -1 10 "DIA. 250 CFM TYPICAL WOMEN'S ROOM 123 BREAK ROOM 14x14 UP TO EF -1 ON ROOF r7 8" e 14 "x10" 118 S -1 10 "DIA. 250 CFM re NEW NMI S -2 8 "DIA. 180 CFM SALES AREA 101 MOTHER'S ROOM 124 BREAK ROOM AREA PLAN SCALE = 1/4" = 1' -0" 8"o 5-1 8 "DIA. 220 CFM REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 6 2010 City of Tukwila BUILDING DIVISION 110033 TED ECEIVED MAR 112010 PERMIT CENTER UUNS I K. MA; Z KIVISIUNS NO. DATE DESCRIPTION .02/26/10 ISSUED FOR 90% LL REVIEW 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 1 1 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: BJP CHECKED BY: BJP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE architecture F engineering, P.C. _' 18114 Mile: Rd NE Grand Rapids, Mi 49525 www.progressiveae.com LL A. FE,o OF WAS/ f/ 1/ � --f , ? 9/ f `. i .o 37 712 O '�/' ST Cad,. /ON / /./ T�)'1 d '� � D �I J%i1 -_- -, - --_.� it, � � \- J� - -----1 /--- J �-`� I�. , J `ll c1 I i l S: STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION T U KW I LA, WA DRAWING TITLE ENLARGED HVAC PLAN AND SECTIONS SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. M202 R ROOF TOP UNIT SCHEDULE MARK NUMBER STATUS MANUF. MODEL NO. NOMINAL TONS TOTAL COOLING SENSIBLE COOLING TOTAL CFM ENTERING DB/WB CONDITIONS AMBIENT HEAT INPUT (BTUH) . HEAT OUTPUT (BTUH) BLOWER H.P. OR K.W. OUTSIDE AIR (CFM) MIN. /MAX. POWER SUPPLY (VOLTS- PHASE) MCA MOCP FILTERS EXTERNAL S.P. (" OF W.C.) APPROX. WEIGHT EER/IPLV /SEER ECONOMIZER BAROMETRIC RELIEF DAMPERS NEW SEISMIC ROOF CURB BOTTOM POWER ENTRY KIT CIRCUIT BREAKERS, FACTORY INSTALLED LENNOX SUPPLY AND RETURN DROP BOX PACKAGE SMOKE DETECTOR S RA FACTORY INSTALLED ' SERVICE OUTLET (GFCI TYPE, FACTORY MOUNTED, FIELD WIRED BY ELC.) COMMENTS RTU 1 EXISTING LENNOX YCD360A4LA1A2DC1 30 TON 360.0 286.0 105000 80.0/67.0 95 350,000 283,000 10 960/2380 460 -3 85.0 110 2" 0.60 LT.GREEN - 5.5 to 8.0 inches W.C. - 3/8" MRG REFRIGERATION LINESET TO MATCHING CU. Yes Yes No EMI (ENVIOROMASTER) No Yes 750 7 inches W.C. FIELD INST BACnet MODULE RTU 2 EXISTING LENNOX YCD360A4LA1A2DC1 30 TON 360.0 286.0 10500 80.0/67.0 95 350,000 283,000 10 960/2380 460 -3 85.0 110 2" 0.60 X Yes Yes No LAY -IN, REFER TO PLANS FOR # OF SLOTS No Yes TITUS / 50F ALUMINUM FIELD INST BACnet MODULE RTU 3 EXISTING TRANE YCD300B4LODC 25 -TON 300.0 252.0 9000 80.0/67.0 95 250,000 202,000 10 850/2100 460 -3 85.0 110 2" 0.60 ALUMINUM BWE Yes Yes No No Yes 8 SIDEWALL/ DUCT MOUNTED FIELD INST BACnet MODULE RTU 4 EXISTING TRANE YCD300B4LODC 25 -TON 300.0 252.0 9000 80.0/67.0 95 250,000 202,000 7.5 850/2100 460 -3 57.0 70 2" 0.60 Yes Yes No No Yes FIELD INST BACnet MODULE RTU 8 NEW LENNOX LGH060H4E 5 Ton 60.0 47.2 1900 80.0/67.0 95 105,000 85,500 1.0 H.P. 120 460 -3 19.0 20 2" 0.70 930 12.8/ -- -/17.0 Yes Yes Yes Yes Yes No No Yes LENNOX BACnet MODULE RTU 9 NEW LENNOX LGH036H4E 3 Ton 35.3 28.6 '1100 80.0/67.0 95 65,000 52,000 0.5 HP 185 460 -3 23.0 30 2" 0.60 1044 12.7/ -- -/17.0 Yes Yes Yes Yes Yes No No Yes LENNOX BACnet MODULE RTU 10 NEW LENNOX LGH090H4E 7.5 Ton 90.0 77.0 3000 80.0/67.0 95 130,000 104,000 2.0 HP 180 460 -3 20.0 25 2" 0.50 1303 12.5/ - / - Yes Yes Yes Yes Yes Yes Yes Yes LENNOX BACnet MODULE RTU 11 NEW LENNOX LGH048H4E 4 Ton 48.0 37.4 1600 80.0/67.0 95 65,000 52,000 .75 HP 220 460 -3 14.0 15 2" 0.65 600 12.8/ - 17.0 Yes Yes Yes Yes Yes No No Yes LENNOX BACnet MODULE RTU Al EXISTING LENNOX LGH090H4E 10 Ton 120.0 102.6 4000 80.0/67.0 95 270,000 216,000 3 430/1060 460 -3 29.0 35 2" 0.50 Yes No No FIELD INST BACnet MODULE RTU A2 EXISTING LENNOX LGH090H4E 10 Ton 120.0 102.6 4000 80.0/67.0 95 270,000 216,000 3 430/1060 460 -3 29.0 35 2" 0.50 Yes No No FIELD INST BACnet MODULE RTU A3 EXISTING LENNOX LGH090H4E 10 Ton 120.0 102.6 4000 80.0/67.0 95 270,000 216,000 3 430/1060 460 -3 29.0 35 2" 0.50 Yes Yes No Yes No Yes No No FIELD INST BACnet MODULE RTU A4 EXISTING LENNOX LGH090H4E 10 Ton 120.0 102.6 4000 80.0/67.0 95 270,000 216,000 3 430/1060 460 -3 29.0 35 2" 0.50 Yes No Yes FIELD INST BACnet MODULE RTU A5 EXISTING LENNOX LGH090H4E 7.5 Ton 90.0 68.4 13000 80.0/67.0 95 200,000 167,000 3 320/800 460 -3 20.0 29 2" 0.60 Yes No No LENNOX BACnet MODULE RTU A6 ABANDON LENNOX GCS16- 261 -50 -5P 2 Ton 24.0 16.7 ' 600 - 95 50,000 36,000 0.33 - 208/1/60 17.7 25 2" 0.60 No No No FAN SCHEDULE MARK NUMBER MANUFACTURER MODEL CFM EXTERNAL S.P. (" OF W.C.) HORSEPOWER VOLT /PH /HZ ADJUSTABLE PULLY DISCONNECT DRIVE PACKAGE BACKDRAFT DAMPER ROOF CURB BIRDSCREEN EF 1 COOK 135C3B 1100 0.33 .25 HP 115/1/60 Yes STD - PREWIRED B Yes Yes Yes APPROVED ALTERNATES: GREENHECK, PENN, TWIN CITY SPLIT SYSTEM SCHEDULE MARK TAG DESCRIPTION MANUFACTURER MODEL NO. TOTAL COOLING CFM SEER VOLTS /PH /HZ WEIGHT ACESSORIES CU 1 CONDENSING UNIT EMI (ENVIOROMASTER) S1CA4D 24000 UNIT SIZE 13 208 - 230/1/60 156 1/2" INSULATION ON SUCTION LINE AND LOW AMBIENT KIT, PROVIDE WITH ELECTRIC HEAT K.W. DISCONNECT SWITCH LINING NOTES COMMENTS ACTARIS B-31R 1 "x1" 400 TO 800 2 P.S.I.G. 7 inches W.C. LT.GREEN - 5.5 to 8.0 inches W.C. - 3/8" MRG REFRIGERATION LINESET TO MATCHING CU. AHU 1 AIR HANDLER EMI (ENVIOROMASTER) WHP18D 24000 750 7 inches W.C. 208 - 230/1/60 115 24V WALL T -STAT 5 P.S.I.G. 2 P.S.I.G. SILVER - 5 P.S.I.G. TO 2 P.S.I.G. - 3/8" NOTES: - REGULATORS ARE FULL CAPACITY INTERNAL RELIEF TYPE. - REGULATORS TO BE INSTALLED WITH RELIEF VENT IN POSITION TO PREVENT ENTRANCE OF WATER (PROVIDE SCREENED VENT ELBOW AS REQUIRED). VENT OPENING TO BE LOCATED 12" MIN. ABOVE ROOF LEVEL. -TAG REGULATOR WITH INLET AND OUTLET SETTINGS, AFFIX WARNING 'DO-NOT REMOVE. TITUS / 300FS ALUMINUM BWE X X 2. CONDENSATE PUMP APPROVED ALTERNATES: AIRDALE, MITSUBISHI, SANYO, FITJITSUSANTO, FIJITSU FTU SCHEDULE MARK NUMBER MANUFACTURER MODEL TYPE UNIT SIZE INLET SIZE CFM HORSEPOWER VOLT /PH /HZ ELECTRIC HEAT K.W. DISCONNECT SWITCH LINING NOTES COMMENTS FTU 1 TITUS ATQS312210 SERIES 2 8 "0 310 1/4 277 -1 -60 2.5 KW Yes 1" CONTRACTOR SHALL INSTALL AN ANALOG ELECTRONIC CONTROLLER /ACTUATOR MODEL #AT76 WITH NIGHT SHUTDOWN, THERMOSTAT AND DIFFERENTIAL PRESSURE SWITCH IN SUPPLY DUCT UPSTREAM OF FTU -1. REFER SEQUENCE OF OPERATION ON THIS SHEET. MOTHERS RM. APPROVED ALTERNATES: PRICE, NAILOR FTU SEQUENCE OF OPERATION FAN OPERATION: WHENEVER AIR HANDLER IS ON, UNIT FAN RUNS CONTINUOUSLY. WHENEVER AIR HANDLER IS OFF, UNIT IS DISABLED. COOLING MODE: WITH SUPPLY TEMP. BELOW 72 °F, UNIT OPERATES IN COOLING WITH REHEAT MODE. WITH ROOM TEMPERATURE AT COOLING SETPOINT, UNIT DELIVERS MINIMUM COOLING CFM. AN INCREASE IN ROOM TEMPERATURE CAUSES AIRFLOW TO INCREASE, REACHING MAXIMUM COOLING CFM 2 °F ABOVE COOLING SETPOINT. ON A DECREASE IN ROOM TEMPERATURE, MIN. COOLING AIRFLOW IS MAINTAINED. AT 0.4 °F BELOW HEATING SETPOINT, THE FIRST REHEAT STAGE IS ENERGIZED. THE OPTIONAL SECOND AND THIRD REHEAT STAGES ARE ENERGIZED AT 1.1 & 1.7 °F BELOW HEATING SETPOINT, RESPECTIVELY. AN INCREASE IN ROOM TEMPERATURE DE- ENERGIZES THE REHEAT STAGES AT 1.5, 0.9 & 0.2 °F BELOW HEATING SETPOINT. HEATING MODE: WITH SUPPLY TEMPERATURE ABOVE 78 °F, UNIT OPERATES IN HEATING WITH REHEAT MODE. WITH ROOM TEMP. AT HEATING SETPOINT, UNIT DELIVERS MIN. HEATING CFM. A DECREASE IN ROOM TEMPERATURE CAUSES AIRFLOW TO INCREASE, REACHING MAX. HEATING CFM 2°F ABOVE HEATING SETPOINT. AT 0.4 °F BELOW HEATING SETPOINT, THE FIRST REHEAT STAGE IS ENERGIZED. THE OPTIONAL SECOND AND THIRD REHEAT STAGES ARE ENERGIZED AT 1.1 & 1.7 °F BELOW HEATING SETPOINT, RESPECTIVELY. AN INCREASE IN ROOM TEMP. DE- ENERGIZES THE REHEAT STAGES AT 1.5, 0.9 & 0.2 °F BELOW HEATING SETPOINT. MECHANICAL SYMBOLS AND ABBREVIATIONS LEGEND A.F.F. ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT APPROX. APPROXIMATE BLDG. BUILDING CFM CUBIC FEET PER MINUTE COL. COLUMN CU DIA.;O DN. DOM. DWG. EER EF ELC EMS EQUIP. EXH. FIN. FL. FURN. GCC HAC H.P. HVAC IN. IPLV KW MBH MFR. MIN. N.I.C. N.T.S. O.A.;O /A PBC PLBG. R.A. REQ'D. RTU S.A. SEER S.P. SENS. SHT. SVC. T -STAT TF TYP. UH W/ W/O W VAV W.C. 0 CONDENSING UNIT DIAMETER DOWN DOMESTIC DRAWING ENERGY EFFICIENCY RATIO EXHAUST FAN ELECTRICAL CONTRACTOR ENERGY MANAGEMENT SYSTEM EQUIPMENT EXHAUST FINISHED FLOOR FURNISHED GENERAL CONSTRUCTION CONTRACTOR HEATING AND AIR COND. CONTRACTOR HORSE POWER HEATING, VENTILATING, AIR COND. INCH(ES) INTEGRATED PART LOAD VALUE KILOWATT(S) 1000 BTUH MANUFACTURER MINIMUM NOT IN CONTRACT NOT TO SCALE OUTSIDE AIR PLUMBING CONTRACTOR PLUMBING RETURN AIR REQUIRED ROOF TOP UNIT SUPPLY AIR SEASONAL ENERGY EFFICIENCY RATIO STATIC PRESSURE SENSIBLE SHEET SERVICE THERMOSTAT TRANSFER FAN TYPICAL UNIT HEATER WITH WITHOUT WATT(S) VARIABLE AIR VOLUME WATER COLUMN PHASE DEGREES FAHRENHEIT 7 x S1 -125 624 AR UNIT MARK GAS PIPING UNION DIRT LEG GAS COCK DAMPER SUPPLY AIR DIFFUSER RETURN OR EXHAUST GRILLE THERMOSTAT FLEXIBLE DUCT CONNECTION RETURN, EXHAUST, OR OUTSIDE AIR DUCT DISCHARGE OR SUPPLY AIR DUCT SUPPLY AIR -AIR QUANTITY (CFM) DIFFUSER DIFFUSER SIZE (NECK/FRAME) DESIGNATION EQUIPMENT DESIGNATION KEYED NOTES ON DRAWING REVISIONS GAS PRESSURE REGULATOR SPECIFICATIONS MANUFACTURER MODEL CFH CAPACITY INLET PRESSURE SET POINT SPRING COLOR - RANGE - ORIFICE ACTARIS B -31 R 3/4 "x3/4" UP TO 150 2 P.S.I.G. 7 inches W.C. LT.GREEN - 5.5 to 8.0 inches W.C. - 1/8" ACTARIS B -31 R 3/4 "x1" 150 TO 400 2 P.S.I.G. 7 inches W.C. LT.GREEN - 5.5 to 8.0 inches W.C. - 1/4" ACTARIS B-31R 1 "x1" 400 TO 800 2 P.S.I.G. 7 inches W.C. LT.GREEN - 5.5 to 8.0 inches W.C. - 3/8" ACTARIS B -31 R 1 "x1 1/4" 800 TO 1100 2 P.S.I.G. 7 inches W.C. LT.GREEN - 5.5 to 8.0 inches W.C. - 1/2" ACTARIS B -34R 1 1/4 "x1 1/4" 1100 TO 1900 2 P.S.I.G. 7 inches W.C. GREEN - 5.5 to 8.5 inches W.C. - 1/2" ACTARIS B -34N UP TO 1800 5 P.S.I.G. 2 P.S.I.G. SILVER - 5 P.S.I.G. TO 2 P.S.I.G. - 3/8" NOTES: - REGULATORS ARE FULL CAPACITY INTERNAL RELIEF TYPE. - REGULATORS TO BE INSTALLED WITH RELIEF VENT IN POSITION TO PREVENT ENTRANCE OF WATER (PROVIDE SCREENED VENT ELBOW AS REQUIRED). VENT OPENING TO BE LOCATED 12" MIN. ABOVE ROOF LEVEL. -TAG REGULATOR WITH INLET AND OUTLET SETTINGS, AFFIX WARNING 'DO-NOT REMOVE. DIFFUSER & GRILLE SCHEDULE MARK APPLICATION MANUFACTURER / MODEL MAT'L. FINISH ACCESSORIES REMARKS VC PC 1 CEILING TITUS / TDC STEEL BWE X LAY -IN T -BAR, 24 "x24 ", ALL WITH 18 "x18" LOUVER FACE 2 CEILING TITUS / TDC ALUMINUM BWE X SURFACE MOUNTED W /DAMPER & PLASTER FRAME 3 SIDEWALL/ DUCT MOUNTED TITUS / 300FS ALUMINUM BWE X X WALL MOUNTED 4 CEILING SLOT DIFFUSER TITUS / TBDI 30 STEEL BWE X LAY -IN, REFER TO PLANS FOR # OF SLOTS 5 CEILING TITUS / 50F ALUMINUM BWE X SURFACE MOUNTED 6 CEILING TITUS / 50F ALUMINUM BWE SURFACE MOUNTED 7 CEILING TITUS / 50F ALUMINUM BWE LAY -IN T -BAR 8 SIDEWALL/ DUCT MOUNTED TITUS / 350FS STEEL BWE SURFACE MOUNTED 9 AREOBLADE SUPPLY REGISTER TITUS / 122RS STEEL BWE X X (NOT USED) DUCT MOUNT WITH DAMPERS DOUBLE DELFECTION ** - PROVIDE LOUVER WITH FINISH: BAKED OFF -WHITE ENAMEL (BWE) S= SUPPLY AIR OPPOSED BLADE DAMPERS. ACCESSORIES: VC- VOLUME CONTROL R = RETURN AIR PC- PATTERN CONTROL E = EXHAUST AIR T = TRANSFER AIR (SYSTEM TAG LISTED ON PLANS) APPROVED ALTERNATES: PRICE, NAILOR, TUTTLE & BAILEY ** OWNER SHALL PROVIDE FACTORY INSTALLED SMOKE DETECTORS IN THE RETURN AIR DUCTS IN NEW RTU'S OVER 2000 CFM (RTU -10), WIRED TO SHUT DOWN THE EVAPORATOR BLOWER UPON ACTIVATION. HAC SHALL WIRE SMOKE DETECTORS TO THE FIRE ALARM SYSTEM (SUPERVISORY SIGNAL). REFER TO NOTICE TO BIDDERS NOTE BELOW. NOTICE TO BIDDERS REF: SMOKE DETECTORS FOR ROOFTOP UNITS THE LENNOX ROOFTOP UNITS ARE NORMALLY FURNISHED WITH SMOKE DETECTORS FACTORY INSTALLED AND WIRED IN THE RETURN AIR PATH FOR UNITS 2000 CFM AND LARGER. DETECTORS SHALL COME FACTORY WIRED TO SHUT DOWN RTU. POWER FOR DETECTORS SHALL BE PROVIDED BY THE FIRE ALARM CONTRACTOR. DURING BIDDING, THE HAC SHALL BE RESPONSIBLE TO DETERMINE IF THE LOCAL CODES AND /OR THE LOCAL BUILDING /FIRE DEPARTMENT OFFICIALS REQUIRE THE SMOKE DETECTORS TO BE INSTALLED IN THE DUCTWORK IN LIEU OF BEING FACTORY INSTALLED WITHIN THE LENNOX UNITS. WHEN APPLICABLE, THE HAC SHALL BE RESPONSIBLE TO INCLUDE IN HIS BASE BID WORK, THE COST TO REMOVE, RELOCATE, AND REWIRE THE SMOKE DETECTORS IN LOCATIONS AND ARRANGEMENTS ACCEPTABLE TO AND AS REQUIRED BY LOCAL CODES AND OFFICIALS. IT IS PRESUMED THE HAC IS OR WILL BE FAMILIAR WITH THE LOCAL CODES AND PRACTICES. THEREFORE, THE CONTRACTOR'S FAILURE TO BE THUS INFORMED SHALL NOT CONSTITUTE JUSTIFICATION FOR AN ADDITIONAL PAYMENT FOR RELOCATING AND REWIRING SMOKE DETECTORS. THE SMOKE DETECTORS SHALL BE PROVIDED WITH RTU INCLUDING THE SINGLE POINT CONNECTION OPTION. RTU SPECIAL NOTES ALL RTU'S EQUIPPED WITH ECONOMIZERS SHALL BE PROVIDED WITH BAROMETRIC RELIEF DAMPERS. RTU -1, 2, 3, 4, A3 & A6 SHALL BE CONFIGURED FOR DEMAND CONTROL VENTILATION. UNITS SHALL PROVIDE THE DAMPER CONTROL AND AUTOMATED LOGIC THE SPACE CO2 SENSORS AS SHOWN ON THE DRAWINGS. THE BASE CO2 SETPOINT SHALL BE 500 PPM. THE OUTDOOR AIR DAMPER SHALL MODULATE TO MAXIMUM POSITION WITH RISE IN CO2 TO 1200 PPM. OWNER SUPPLIED ITEMS SHALL BE INSTALLED BY CONTRACTOR. REFER TO DRAWING EMS1 FOR MORE DETAILED INFORMATION ABOUT DEMAND CONTROL VENTILATION. VENTILATION NOTE: THE BASE SALES FLOOR VENTILATION IS BASED ON ASHRAE 62 -2004. THE BASE VENTILATION SHALL BE PER AREA CRITERIA OF 0.12 CFM /SQFT. DEMAND CONTROL VENTILATION (CO2) SHALL BE UTILIZED TO PROVIDE ADDITIONAL VENTILATION FOR THE PEOPLE COMPONENT OF THE VENTILATION CODE, OR 7.5 CFM/PERSON. FOR THIS LOCATION, THE FULL VENTILATION IS BASED ON IMC -2006, OR 0.3 CFM /SQFT. REFER TO DRAWING EMS1 FOR ADDITIONAL INFORMATION. EACH NEW AND EXISTING RTU SHALL BE PROVIDED WITH A TEMPERATURE SENSOR. THE SENSORS SHALL BE SHIPPED LOOSE WITHIN THE UNIT TO BE MOUNTED BY THE E.C. PER DRAWING EMS1. THE LENNOX CATALOG NUMBER IS 94L60. HEATING & COOLING SET POINTS UNLESS OTHERWISE DIRECTED BY BABIES "R" US, THE FOLLOWING SET POINTS SHALL APPLY TO ALL SYSTEMS: OCCUPIED COOL - 78° UNOCCUPIED COOL - 85° OCCUPIED HEAT - 68° UNOCCUPIED HEAT - 58° NOTE: THERMOSTATS FOR HEATING ONLY SHALL HAVE SET POINT RANGE OF 55°F TO 75 °F FOR HEATING & COOLING SHALL HAVE SET POINT RANGE OF 55 °F TO 85°F (ADJ.) TO PROVIDE A RANGE OF 10 °F BETWEEN FULL HEATING AND FULL COOLING. ALL HEATING & COOLING THERMOSTATS SHALL BE DESIGNED TO TERMINATE ALL HEATING @ 68 °F & ALL COOLING @ 78°F. HVAC EQUIPMENT SHALL COMPLY WITH GOVERNING CODE. RTU PLENUM DIFFUSER SPECIFICATIONS PROVIDE BY OWNER/INSTALLED BY HAC: 1. SUPPLY PLENUM DIFFUSER AS MANUFACTURED FOR BABIES 'R' US BY LENNOX INC APPROVED SUPPLIER: CONTACT INFORMATION LENNOX, INC. PHONE: FAX: EMAIL: (972) 497 -6884 (972) 497 -5112 MICHAEL .CORP.JOHNSTON @LENNOXINTL.COM 2. PLENUM DIFFUSERS WITH DRUM LOUVER SHALL BE OF SIZES AS RECOMMENDED BY MANUFACTURER, BASED ON CURBS PLUS DLPD MODEL. RTU -1 & 2: DLPD - 5010 -30 RTU -3 & 4: DLPD - 4010 -25 RTU -3A & 6A: DLPD - 2406 -10 RTU -10: DLPD - 2406 - 10 (USE 10 -TON SIZE, BLANK OFF TWO SIDES) 3. ENTIRE PLENUM DIFFUSER SYSTEM SHALL BE PAINTED WHITE IN FIELD. SEISMIC ROOF CURB SPECIFICATIONS BRU SHALL PROVIDE AND HAC TO INSTALL: THY CURB TC -3 INSULATED CURB WITH SEISMIC CAPABILITY FOR SEISMIC SITE CLASS D, WITH THY -CURB SEISMIC RESTRAINT BRACKETS. ti,oO33 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 6 2010 City of Tukwila BUILDING DIVISION RECEIVED MAR 112010 PERMIT CENTER CONSTR. DOC & REVISIONS NO. DATE 02/26/10 03/08/10 DESCRIPTION ISSUED FOR 90% LL REVIEW ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: BJP CHECKED BY: RAF PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE P architecture engineering, P.C. 18114 Mile Rd NE Grand Rapids, Mi 49525 www.progressiveae:com STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 is THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION T U KW I LA, WA DRAWING TITLE MECH SCHEDULES AND DETAILS SCALE 12" .1-0" ISSUE DATE MARCH 9, 2010 SHEET NO. M301 AR)