Loading...
HomeMy WebLinkAboutPermit M10-034 - PLATO'S CLOSETPLATO'S CLOSET 17095 SOUTHCENTER PY EXPIRED 03 -30 -I1 M10 -034 Parcel No.: 2623049069 Address: Suite No: Citygf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwi1a.wa.us 17095 SOUTHCENTER PY TUKW MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M10 -034 04/05/2010 10/02/2010 Tenant: Name: Address: Owner: Name: Address: PLATO'S CLOSET 17095 SOUTHCENTER PY , TUKWILA WA CENTER PL SHOPPING CTR LLC 810 3RD AVE SUITE 140 , SEATTLE WA Contact Person: Name: PEGGY PEEL Address: 4600 S 134 PL , SEATTLE WA Contractor: Name: Address: Contractor License No: Phone: Phone: 206 248 -8747 Phone: Expiration Date: DESCRIPTION OF WORK: REPLACE (2) ROOFTOP GAS PACKAGE A/C UNITS Value of Mechanical: $27,000.00 Type of Fire Protection: UNKNOWN Fees Collected: $509.81 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 2 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment0 * *continued on next page ** doc: IMC -10/06 M10-034 Printed: 04 -05 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http://www.ci.tukwila.na.us Permit Number: M10 -034 Issue Date: 04/05/2010 Permit Expires On: 10/02/2010 Permit Center Authorized Signature: Date: l I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The 'anting of ithis pe 't does tot presume to give authority to violate or cancel the provisions of any other state or local laws regulating ns ru a co c • Sign of work. I am authorized to sign and obtain this mechanical permit. Print Name: IA • t Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M10 -034 Printed: 04 -05 -2010 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049069 Address: 17095 SOUTHCENTER PY TUKW Suite No: Tenant: PLATO'S CLOSET PERMIT CONDITIONS Permit Number: M10 -034 Status: ISSUED Applied Date: 03/22/2010 Issue Date: 04/05/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall•be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (EMC 606.1, 606.2.1) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M10 -034 Printed: 04 -05 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -034 Printed: 04 -05 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any construction or the performance of work. Signature: Print Nam Q— Date /C) of law and ordinances governing other work or local laws regulating doc: Cond -10/06 M10 -034 Printed: 04 -05 -2010 CITY OF TUKWILA', Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hitp://www.ci.tukwila.wa.us 0 Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: King Co Assessor's Tax No.: aZ4,2 30 90 Tenant Name: Property Owners Name: Mailing Address: /70?5 Suite Number: 4/4 Floor: New Tenant: ❑ Yes 'o i J.,4 9t/ S 'City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: (R.--7,7_. c �y7,�a1L Mailing Address: 400 S . /3 /e2 E -Mail Address: /9e..?,? no @ io /ctd4 y p a - KS . corn Day Telephone: QZo G -z 4/(- 74'7 ifIAL City Fax Number: 9 .P/� State Zip -B Too GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Contact Person: .51400 S . /3 1L E -Mail Address: City GD Contractor Registration Number: /TD LAD Pr 3 79 /✓0 Day Telephone: Fax Number: Expiration Date: State Zip o?o 6,-.2618 -8747 p2O to - .2 518 -$ 70 o r‘,2O // ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:\Applications \Forms - Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 MECHANICAL PERMIT INF TION — 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: . Mailing Address: 416OO S / /3 '/ i 1/4- ?y/62 City State Zip Contact Person: c7a. (.R.t.Q Day Telephone: o2c 6 • _4{g- g 74f 7 E -Mail Address: e ye?),, A o / <eel, yp d rAIS. Gont Fax Number: -g 7e9 D Contractor Registration Number: /10 11+ b Pr 37 ?/V2 Expiration Date: ?' /t 0 // Valuation of Mechanical work (contractor's bid price): $ a 00 Scope of Work (please provide detailed information): yez—t 14/(1' Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ... Fuel Type: Electric ❑ Gas.... Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP/I00,000 BTU Furnace> 100K BTU Evaporator Cooler Diffuscr 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator Comm /Ind H:Wpplications \Forms - Applications On Line 2009 Applications \1-2009 - Permit Application.Jo. Revised: 1 -2009 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 163.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: �'``s pe_g_Q Date: 3/! 9/2 / Print Name: -2% y %, 7 ' e / Day Telephone: Mailing Address: I/16 d o S, / 3 1/- p_, ILIA¢ Date Application Accepted: City a.o' a211-f717 99/62 State Zip 1 Date Application Expires: 1-2,21 to Staff Initials: H :\Applications \Forms- Apphcanons On Line \2009 Applications\ 1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 1 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049069 Permit Number: M10 -034 Address: 17095 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 03/22/2010 Applicant: PLATO'S CLOSET Issue Date: Receipt No.: R10 -00574 Initials: User ID: WER 1655 Payment Amount: $407.85 Payment Date: 04/05/2010 01:01 PM Balance: $0.00 Payee: HOLADAY PARKS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 040629 ACCOUNT ITEM LIST: Description 407.85 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 407.85 Total: $407.85 dor.. Rer.eint -0R Printed. 04 -05 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049069 Permit Number: M10 -034 Address: 17095 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 03/22/2010 Applicant: PLATO'S CLOSET Issue Date: Receipt No.: R10 -00497 Payment Amount: $101.96 Initials: JEM Payment Date: 03/22/2010 09:52 AM User ID: 1165 Balance: $407.85 Payee: CONNIE L HARDIN, HOLADAY PARKS FAB INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 062503 ACCOUNT ITEM LIST: Description 101.96 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 101.96 Total: $101.96 P YME ECEB T doe: Receipt -06 Printed: 03 -22 -2010 o- ECTION NO. INSPECTION RECORD Retain a copy with permit t4( —d3- PERMIT NO--. CITY OF TUKWILA BUILDING DIVISION ' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pr }j//i% ype of Ins■pection: //Aj�J ezji , y���'''.j�y/y + (_i A dress: ( q5 3 \ r Date Called: Special Instructions: 6. 3a -,( Date Wanted: J �a m Requester: Phone 1.40(0 — s (? -7337 'El Approved per-applicable codes. Corrections required prior to approval. COMMENTS: DlryNnve.t.t.ort J 14 •mac #.1400 ,sec [,% toi .# e rlp d -- t%-1 f r t r EIN' PECTION FEE REQUIRED. Prior to next inspection: fee must be t 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. L�i. %€f. Y..m 41�•..^��efF�w.% ' Y � f C . R ...` !v`�f.. . Y . . . ! 9 / . }.., •. ..`. ILIA CO FILE COPY Permit No., Lincoln Center Business Park 555 116th Ave. NE, Suite 150 Bellevue, WA 98004 Phone 425.644 -6400 Fax 425.644 -0463 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 31 2010 City of Tukwila BUILDING DIVISION PLATOS CLOSET MECHANICAL UNIT SUPPORTS 17095 SOUTHCENTER PKWY TUKWILA, WASHINGTON 98188 FOR HOLADAY PARKS, INC. STRUCTURAL CALCULATIONS FEBRUARY 22, 2010 JOB: 124-1001 I EXPIRES I 1 .-L% 04,./) crtYRSH MAR 2 2 2010 PERMIT CENTER MWOff 4 z >l¢ e17 ) L ■-P" Ex )f " %✓G 4-7c ) y PARTIAL ROOF FRAMING PLAN NOTES:. ..... 1) CONTRACTOR TO VERIFY ALL SIZES, DIMENSIONS, AND LOCATIONS AT FIELD. 2) CONTRACTOR TO VERIFY ALL EXISTING ROOF FRAMING MEMBER SIZES. 3) CONTRACTOR TO VERIFY MECHANICAL UNIT SIZE, WEIGHT AND LOCATIONS. Cdr w /1.4 ,.reQ , Sheet No 9 Z -1e .bb No. risr -• a f�17 4" A1�o�T G l/�'l3 To .7 U ✓�> Mr!P ✓j (#) - . j Z. Elt4-/./ fzi>E af. fifes .vim /r P -f. *))43 -G >� -ij --!. 27 7-41 4f ' /Cz) -)dd >o6.✓s�)Ls 4BcNE ✓, Y'7 • z›4)4- ,Z/r "77" —, x;i6 /(f))a fir,,.%✓ 1-,4 )4 s 4t7-) /o6 Proiedroublect 7I1'7 f GLaje r f v4 r✓�1�, ,,,iii 4 j -v X 93° )1.3) ��' `.��- 2) .�G .rEGd ,.✓ „f7C4) _ J.z 1 G!/..G' Th r. zx14- »' >djiT A- .singCp f L xD- #lS —'G LTa lr�� Z ) 4 C v> J,'-' TyJ�� g G. ✓, V) Et-,/ Z �) f c. �G�r -s s GG �iET swot No 339 2 -Jo Job No Jug -).=-ci ROOF LOADS: DEAD LOAD: B.U. ROOFING 2 PSF PLYWOOD 1.8 2X6 c 24" o.c. 1 SPRINKLER 1.5 INSULATION 1 PURLIN @ 5' o.c. 2.4 CEILING 2 MISC. / MECH. 2.3 14 PSF LIVE LOAD: SNOW 25 PSF TOTAL LOAD: 39 PSF MECHANICAL UNIT DATA: RTU -I = 6171bs RTU -2 = 930 lbs O V 4 am;ec; SuDea 7L /),70J GG�1G' BY Date )a Sr.eet No 4/ / J^O No EXISTING 4x14 ROOF PURLIN:. (RTU -1) KLU DL LL = 19.00 FT 1:2:00 25.00 PSF PSF SPACING= 5.00 • FT P (Mech.) : = 617 P (Mech.) / PURLIN.= 309 UNIT DIST. 4.00 W(DL +LL)= (DL +LL) x (S) = LBS' LBS = - FT 185 PLF CHECK: 4 x 14 D.F. #2 (OLD GROWTH) b = 3 :50 • IN: - 113.25 IN. A " bxh = 46.38 S . = bxh ^216 = 102.41 1 = bxhA3 / 12= 678.48 E' = 1800: KSI M= WxL ^2/8 +PxL1xL2IL = R = WxL /2 ±PxL2/L V • R- (Wxh /12) 9,322 FT-LBS 2,001 LBS 1,797 LBS Fb =Mx12 /S = 1,092 PSI <1250PSIx1.15 O.K. Fv =Vx1.5 /A • = 58 PSI < 95 PSIx1.15 • O.K. efl. = 5 x W x L ^4" x "12 ^3 / (384 x E x I) = 0.50 IN = L / 460 0 p4.47 J C/����' Sheet 47 3 9 Date Z a Joe No. )24--Joe)J EXISTING 4x14 ROOF PURLIN: (RTU -2) KLU = 19.00 FT DL = 12:00 - PSF LL = 25.00 PSF SPACING= 5:00 FT P (Mech.) = 930 LBS P (Mech.) / PURL -IN = 465: LBS UNIT DIST. 7.00 FT W(DL +LL) =. (DL ±LL) x (S) = 185 - PLF CHECK: 4 x 14 D.F. #2 (OLD GROWTH) b h = 3.50 IN. 13.25 IN. A = bxh = 46.38 S = bxh ^216 = 102.41 I = • bxh ^3 / 12= 678.48 E: = 1800- - • KSI M = WxL ^2 /8 +.PxL1xL2/L = 1.0,404 R WxL /2: +PXL2/L V =.R- (Wxh /12) FT -LBS 2,051 LBS 1,847 LBS Fb = M x 12 / S = 1,219 PSI < 1250 PSIx1.15 O.K. Fv = V x 1.5 /:A- 60 • PSI < 95 PSIx1.15 O.K. Defl: = 5xWxL "4x'12 ^3 /(384xExI) = 0.55 IN = L / 412: • 0 v 4 ProjectSubiaci l041-7—05 s G G 616.7 BY Date Z,lo Job140. TYP. 4X4 SLEEPER: KLU = 5.00. FT P (mech.)= 930:00 lbs w (mech.)= 93 : PLF SPACING= 7.40 FT • w (snow) = 92.5 PLF W(TOTAL) =186 - PLF TRY: 4 x 4 D.F. #2 b .. = ... 3:50 h = 3.50: IN. A = b x = 12.25 S = bxh "2 /6= 7.15 I = bxh "3 / 12= 12.51 E = 1700 KSI M = W x LA2 /8 = 580 • FT-LBS R =WxL /2 = 464 LBS V_= R- (Wxh /12) = 410. LBS Fb = M x 12 / S = 973 PSI < 1140 PSIx1.15 O.K. Fv = V x 1.5/A = 50 • PSI < 95 PSIx1.15 O.K. Defl.= 5xWxLA4x12 '3 /(384xExI) = 0.12 IN = L/ 489 pioocusubpzt Pi ,9 ro r G BY Date - to Sheet No7) TYP. 2X12 SLEEPER: KLU = 5.00 FT P (mech.)= 930.00 • -Ibs w (mech.)= 93 SPACING= 7.40 -w (snow) = 92.5 *TOTAL): 186 PLF FT PLF PLF TRY: 2 x 12 b. F. #2 b .- = 1.50 . :. IN. h = . 11.25 IN. = bxh = 16.88 = bxhA2 / 6 = 31.64 = bxhA3 / 12= 177.98 = 1700- KSI M = W x L"2 / 8 = 580 FT -LBS R= WxL /2 = 464. : LBS V: =.R -.(W x h / 12) := 290 LBS Fb = M x 12 /S = 220 PSI < 1140 PSIx1.15 . O.K. Fv = V x 1.5 / A = 26 PSI < 95 PSIx1.15 O.K. Detl. = 5 x W x L ^4 x 12 ^3' f (384 x E x I) = 0.01 IN = L/ 6959 a .7I 7 5GG�6T By �• lr• Date y_fa Job NO )Z4Y - -Io° LATERAL DESIGN:(IBC 2006, ASCE 7 -05) (A) WIND - BASIC WIND SPEED = 85 MPH (FIG. 6-1, ASCE 7 -05) EXP. "B" Iw = 1.0 Kd = 0.9 (TABLE 6-4, ASCE 7 -05) Kz = 0.7 UP TO 30' Kzt= 1.0 (FIGURE 6-4, ASCE 7-05) Gf = 0.85 (GUST FACTOR) qz = 0.00256 x Kz x Kzt x Kd x V "2 x I (EQ. 6-15) qz = 11.7 PSF Cf = 1.3 (FIG. 6-21, ASCE 7 -05, H/D < 1.0, FOR MECHANICAL UNIT, F= gzxGfxCfxAf (EQ.6 -28) F = 12.88 Af UNIT LENGTH (L) = 5.8 FT UNIT WIDTH (W) = 3.7 FT UNIT HIGHT (H) = 3.00 FT SHORT DIRECTION: F wind = 291 Ibs LONG DIRECTION: F wind = 186 Ibs O V 4 Prolect.SubAc 71 ' 5 GLdf67 Tl/ie //A / Date -�0 �9 Job No p LATERAL DESIGN:(IBC 2006, ASCE 7 -051 7r/ — 2) (A) WIND - BASIC WIND SPEED = 85 MPH (FIG. 6-1, ASCE 7 -05) EXP. "8" Iw = 1.0 Kd = 0.9 (TABLE 6-4, ASCE 7 -05) Kz= 0.7 UPTO30' Kzt= 1.0 (FIGURE 6-4, ASCE 7 -05) Gf = 0.85 (GUST FACTOR) qz = 0.00256 x Kz x Kzt x Kd x V "2 x I (EQ. 6-15) qz = 11.7 PSF Cf = 1.3 (FIG. 6-21. ASCE 7 -05, HID < 1.0, FOR MECHANICAL UNIT, F= qzxGfxCfxAf (EQ.6 -28) F = 12.88 Af UNIT LENGTH (L) = 7.4 FT UNIT WIDTH (W) = 4.4 FT UNIT HIGHT (H) = 3.4 FT SHORT DIRECTION: F wind = 421 Ibs LONG DIRECTION: F wind = 250 Ibs Prgeet,5kb;ea At 725- GLas�r w.cv'JL�9 � w� Date 210 —Soso No ) Job t� PLATOS CLOSET Date and Time: 2/19/2010 4:21:37 PM MCE Ground Motion - Conterminous 48 States Zip Code - 98188 Central Latitude = 47.447736 Central Longitude = - 122.273462 Period MCE Sa (sec) ( %g) 0.2 133.7 MCE Value of Ss. Site Class B 1.0 046.0 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 133.7 Sa = FaSs, Fa = 1.00 1.0 070.8 Sa = FvS1, Fv = 1.54 1 SEISMIC (2006 IBC) - -(,er!/- ZIP CODE: 98188 LATITUDE = 47.4477 LONGITUDE = - 122.2735 Ss = 1.337 g S1= 0.46g SITE CLASS "C" SDC = D Fa = 1 Fv = 1.54 Sms = Fa x Ss = 1.337 g Sm1 = Fv x S1 = 0.71 g Sds = 2/3 Sms = 0.89 g Sd1 = 2/3 Sm1 = 0.47 g Fp = (0.4 Ap.Sds.Wp /(Rp /Ip)) / (1 + 2 Z/H) Ap = 2.5 Ip = 1 Rp = 6 Sds = 0.89 (EQ. 13.3 -1) pLAT�S G4 rf 7 i� a TV/C ✓ /li�� v✓%f Y BY Sheet No 9 Dare 2-- 10 Job No 2/H = 1 Wp = 617 Ibs Fp = 275 Ibs Fp (MAX) = 1.6 Sds.Ip.Wp = 880 Ibs > Fp O.K. Fp (MIN) = 0.3 Sds.Ip.Wp = 165 Ibs < Fp O.K. Fp (ASD) = Fp / 1.4 = 196 Ibs (WIND GOVERNS IN SHORT DIRECTION) CHECK UNIT STABILITY: SHORT DIRECTION: F(WIND)= 291 Ibs M (O.T.) = 437 Ibs-ft M (RESIs.) = 1141 Ibs -ft 0.70 M (R)= 799 Ibs-ft > M (O.T.) NO UPLIFT USING: MINIMUM (4)412 SCREWS EACH SIDE OF THE UNIT / CURB F(wind) / #12 SCREW= 36 Ibs - O.K. 0 0 4 te Project subpu te,]14, wig By Date Sneer Nn Job no SEISMIC (2006 IBC) ZIP CODE: 98188 LATITUDE = 47.4477 LONGITUDE = - 122.2735 Ss = 1.337 g S1 = 0.46 g SITE CLASS "C" SDC = D Fa = 1 Fv = 1.54 Sms = Fa x Ss = 1.337 g Sm1 = Fv x S1 = 0.71 g Sds = 2/3 Sms = 0.89 g Sd1 = 2/3 Sm1 = 0.47 g Fp = (0.4 Ap.Sds.Wp /(Rp /Ip)) / (1 + 2 Z/H) Ap = 2.5 Ip = 1 Rp = 6 Sds = 0.89 (EQ. 13.3 -1) 0 v 4 Protecl:$ubmU pL , eJ By ,9.6-, Date 2 -10 See !• :D. Job No ZJH= 1 Wp = 930 Ibs Fp = 414 Ibs Fp (MAX) = 1.6 Sds.Ip.Wp = 1,326 Ibs > Fp O.K. Fp (MIN) = 0.3 Sds.ip.Wp = 249 Ibs < Fp O.K. Fp (ASD) = Fp/1.4 = 296 Ibs (WIND GOVERNS IN SHORT DIRECTION) CHECK UNIT STABILITY: SHORT DIRECTION: F(WIND)= 421 Ibs M (O.T.) = 716 Ibs-ft M (REsis.) = 2046 Ibs -ft 0.70 M (R)= 1432 Ibs-ft > M (O.T.) NO UPLIFT USING: MINIMUM (4)412 SCREWS EACH SIDE OF THE UNIT / CURB F(wind) / #12 SCREW= 53 Ibs - O.K. RoleaSubiett e G6s 7 Date 2�) D Sreei Jo° 1:6 )J4 )e d ) APPENDIX &WARNING Heavy Objects! Do not use cables (chains or slings) except as shown. Each of the cables (chains or slings) used to lift the unit must be capable of supporting the entire weight of the unit. Lifting cables (chains or slings) may not be of the same length. Adjust as necessary for even unit lift. Other lifting arrangements may cause equipment or property -only damage. Failure to properly lift unit could result in death or serious injury. &WARNING Improper Unit Lift! Test lift unit approximately 24 inches to verify proper center of gravity lift point. To avoid dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could result In death or serious injury or possible equipment or property -only damage. Installation Table 1. Maximum unit &comer weights (Ibs /kgsl and venter of gravity dimensions (in /mm) - gas/electric models Unit Model No. Maximum Model Weights() Center of Gravity Corner Weights (in. /mm) Shipping Net A B C D length Width 5C060E 589/312 584/ 181/ 144/ 122/ 137/ 40/1025 24/603 264 82 65 55 62 6 Y5C0726 975/443 843/ 296/ 209/ 158/ 183/ 39/980 21/542 383 1.34 95 72 82 Figure 11. Comer weights A x.11■ OP oRAnn x.11 COMA OP CANOPY ,SIC,, D :WPM or 11Rt11Rt 8y CC906 1016/461 884/ 346/ 198/ 159/ 181/ 36/909 20/519 401 157 90 72 82 YSC102E 1125/510 987/ 325/ 278/ 174/ 210/ 41/1031 21/526 447 147 126 79 95 10 YSC120E 1149/522 1011/ 344/ 265/ 193/ 209/ 40/1020 21/538 459 156 120 88 95 nl welphts ere approximate. no Comer welghts are given for infcrnatior only. Figure 12. Rigging and canter of gravity ATTAIN MAO( m fJ11[ T air Or OtAVITLIDIG 11111111 111 ttznm orh /V1aT11 Table 2. Factory installed options (fiops)/accessory net weights (Ibs /kgs)06 1/I Accessory YSC060ED YSC072E -120ED Net Weight Net Weight 5 Ton 6 -10 Ton Barometric Relief Coll Guards 7/3 10/5 12/5 20/9 .— — Economizer 26/12 36/36 Hinged Doors 10/5 12/5 Manual Outside Air Damper 16/7 26/12 Motonzed Outside Air Damper 20/9 30/14 Oversized Motor 8/4 Roof Curb 61/28 78/35 pl weighis for options not listed are <5 lbs (3kt;s). (D net weight should be added to unit weight when ordering factory- installed accessories. RTSVX38A -EN 17 Dimensional Data Figure 3. Cooling and gas/electric - 3-5 tons standard efficiency, 3 tons high efficiency Notes: 1. A 5tmensscn5 2. NPT C--'r = ..11 • • ot0v,? EvAPORATOR SECTION ACCESE p.ota •, ALTERNATE COMIENSOE DRAW NM Mk HOLE — TOP PANEL — r4NDENSER FAN UP 1C-7.7." • ", 1* WI AS COPINECTION — • zr '• 14+1;i1 Ijitt4 —• 49-40L AND L'OuPPESSOP ACCESS PANEL LI 'it 114 irer Loin" CNOt(rk21. WRE 1-7 =AM D. SOLE 0.-41Arta PCRT MArA0 7:741.P1GLE LEATT POtSER *ARE r 351■10) DIA 101.2 Figure 4. Cooling and gas/electric - 3-5 tons standard efficiency, 3 tons high efficiency downflow airflow supply/return - through the base utilities Noie dtmePs,:r.! r r31 11tivr-ien-E _ :.• . . ki;• I F.t 192 RT-PRCO23-EN MAKE Dimensional Data Figure 13. Cooling and gas/electric - 6, 71/2 (single) tons standard efficiency, 4-5 tons high efficiency Note. All iiinier$10Ps - Figure 14. Cooling and gas/electric 6, 71/2 (single) tons standard efficiency, 4-5 tons high efficiency downflow airflow supply/retum - through the base utilities Note- Al! di!) ens,:),!. 3 04. 1 3C '4•C CAM —} • V.., A^ 76 RT-P — ___....t.... 15: rlo., ....., _ O'ff I i 1 i Olt, ! W. 3 ......., .."..,-' —........., ..ki,Nfs -- • 1,, 3; ' tOkitila *At t'47Z VW. • -,...... . ..- .- '' •-• ... '' 4- 3,,A• / , :::::: ,/- --- ''. CD Sa4 J4.., r` ' ?Jo:. 1 3C '4•C CAM —} • V.., A^ 76 RT-P 02 -01 -2011 Ciao of Tukwila Department of Community Development PEGGY PEEL 4600 S 134 PL SEATTLE WA 98168 RE: Permit No. M10 -034 17095 SOUTHCENTER PY TUKW Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/30/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/30/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, "......b.tiQo e.3.1._ Bill Rambo Permit Technician File: Permit File No. M10 -034 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 09 -01 -2010 PEGGY PEEL 4600 S 134 PL SEATTLE WA 98168 Cli of Tu Jim Haggerton, Mayor Department of Community Development RE: Permit No. M10 -034 17095 SOUTHCENTER PY TUKW Dear Permit Holder: Jack Pace, Director In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and /or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/02/2010 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, qC.A°L Bill Rambo Permit Technician xc: Permit File No. M 10 -034 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PER >;. ITC RD COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -034 PROJECT NAME: PLATO'S CLOSET DATE: 03/22/10 SITE ADDRESS: 17095 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued EP RTMENT : ui ding Divisio ! I Public Works ❑ 4?A 41AL 13-30-1 0 Fire Prevention 0 Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03/23/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04/20/10 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page 0 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Holaday Parks Inc UBI No. 578004089 Phone 2062489700 Status Active Address Po Box 69208 License No. HOLADP1379NO Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/21/1983 State Wa Expiration Date 9/3/2011 Zip 98188 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HOLADPF376NO Holaday Parks Fabrctrs Inc Construction Contractor General Unused 8/20/1963 1/1/1983 Archived Business Owner Information Name Role Effective Date Expiration Date Parks, Gerald T Jr &Nbsp; 01/01/1980 Amount Parks, David L &Nbsp; 01/01/1980 A1CG96430900 Talbot, Paul &Nbsp; 01/01/1980 Nelson, Michael &Nbsp; 01/01/1980 NATIONAL FIRE INS CO OF HARTFO Beck, Dave &Nbsp; 01/01/1980 Oconnor, Bonny K &Nbsp; 01/01/1980 20 Nailon, June A &Nbsp; 01/01/1980 09/01/2008 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 LIBERTY MUTUAL INS CO 23000452 09/01/2002 Until Cancelled $12,000.00 08/23/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 22 OLD REPUBLIC GENERAL INS A1CG96430900 11/01/2009 11/01/2010 $1,000,000.00 10/29/2009 21 NATIONAL FIRE INS CO OF HARTFO 2077698833 09/01/2008 11/01/2009 $1,000,000.0008 /26/2009 20 NATIONAL FIRE INS COOFHAR C2077698833 09/01/2005 09/01/2008 $1,000,000.00 09/02/2005 19 NATIONAL FIRE INS CO OF HART C2077698833 09/01/2004 09/01/2005 $1,000,000.00 08/25/2004 18 NATIONAL FIRE INS CO OF HARTFO 1055784157 09/01/2003 09/01/2004 $1,000,000.0009 /03/2003 Summons /Complaint Information . No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 04/05/2010 GENERAL NOTES 1. ALL TRADES TO LEAVE 36' CLEARANCE IN FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 2. CUTTING, FRAMING, PATCHING AND PAINTING OF WALL, CEILING, AND ROOF OPENINGS SHALL BE BY GENERAL CONTRACTOR. 3. FLASHINGS, PITCH POCKETS, AND CUTTING AND PATCHING OF ROOF OPENINGS SHALL BE BY GENERAL CONTRACTOR. 4. ROOF CURBS, SLEEPERS, AND CANT STRIPS TO BE BUILT AND FASTENED TO THE ROOF BY GENERAL CONTRACTOR. CURBS TO BE CONSTRUCTED ACCORDING TO SIZES PROVIDED BY HOLADAY- PARKS' FIELD MECHANIC. SHIM AS REQUIRED TO MAKE ROOF CURBS AND SLEEPERS LEVEL TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. MAXIMUM ALLOWABLE DEVIATION FROM LEVEL OR FLAT SHALL BE 1/4' IN 10'. ROOF CURBS AND SLEEPERS MUST BE SECURELY FASTENED TO STRUCTURAL SUPPORT MEMBERS. 5. FINAL PAINTING OF GRILLES, REGISTERS, AND DIFFUSERS, AS MAY BE REQUIRED BY ARCHITECT, SHALL BE DONE BY GENERAL CONTRACTOR. 6. GENERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DURING CONSTRUCTION. 7. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED WITH ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL ADEQUACY. IF IT IS NECESSARY TO RELOCATE A UNIT, NOTIFY HOLADAY- PARKS' ENGINEERING DEPARTMENT FOR RE- COORDINATION. B. IN NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEILING WIRES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT OR DUCTWORK. 9. PLUMBER SHALL ROUTE PLUMBING VENTS SO AS TO MAINTAIN MINIMUM 15 FEET OF CLEARANCE FROM OUTSIDE AIR INTAKES. ELECTRICAL COORDINATION 1. WHERE INDICATED ON EQUIPMENT SCHEDULES, THE EQUIPMENT COMES COMPLETE FROM TEE FACTORY WITH MOTOR CONTROLS AS REQUIRED. ELECTRICIAN SHALL PROVIDE SERVICE AND A DISCONNECT PER CODE, AND DO ALL POWER WTI2it+'G, INCLUDING CONNECTING TO EQUIPMENT. GAS PIPING NOTES 1. GAS PIPING SHALL BE SCHEDULE 40 STEEL PIPE WITH MALLEABLE IRON FITTINGS. 2. GAS SUPPLY IS LOW PRESSURE AT METER. 3. PROVIDE A.G.A. APPROVED SHUTOFF VALVE AT EACH DEVICE. SHUTOFF VALVE BODY SHALL HAVE 'SIDE TAP', LOCATED BETWEEN VALVE AND DEVICE, TO ALLOW MEASUREMENT OF INLET GAS PRESSURE. ALTERNATE METHOD IS TO PROVIDE A TEE WITH SEPARATE SHUTOFF VALVE OR GAS COCK AND CAP BETWEEN SHUTOFF VALVE AND DEVICE SHEET METAL NOTES 1. DUCT SIZES INDICATED ON FLANS ARE NdET INSIDE DIMENSIONS. A CAL -OUT SUCH AS 12' X 12' /SL MEANS A 14' X 14' SHEET METAL DUCT WITH 1' SOUNDLINEt, GIVING A NET INSIDE DIMENSION OF 12' X 12 °. 2. DUCTWORK SHALL BE CONSTRUCTED TO DIMENSIONS INDICATED ON PLANS. THE TOLERANCE OF THESE DIMENSIONS SHALL BE AS SPECIFIED IN HOLADAY- PARKS, INC. SHOP STANDARDS MANUAL LENGTHS, AtSI CRITICAL DIMENSIONS BETWEEN DUCTWORK AND OTHER BUILDING /SYSTEM ELEMENTS ARE INDICATED WHERE A LOCATION OR DIMENSION SCALED FROM THE DRAWING WILL NOT BE ADEQUATE. THE TOLERANCE OF CRITICAL DIMENSIONS, IF NOT INDICATED, SHALL DEFAULT TO THAT OF THE INSTALLING MECHANIC'S MEASURING DEVICES. SCALED LOCATIONS OR DIMENSIONS ARE NOT SUBJECT TO TOLERANCE GUIDELINES. 3. DUCT ELBOWS SHALL BE RADIUS TYPE WITH FULL WIDTH THROAT RADIUS, UNLESS SHOWN OTHERWISE TURNING VAN£ ELBOWS SHALL HAVE DOUBLE THICKNESS TURNING VANES INSTALLED IN EVERY RAIL TAB. 4. MATERIALS: a. SOUNDUIdER (INDOORS): 1' THICK, 1 -1/2 LB. DENSITY FIBERGLASS DUCTUNER WITH BLACK MAT FACING. SCHULLER- MANVILLE 'PERMACOTE LNACOUSTIC STANDARD', OR OWENS CORNING 'AEROFLEX PLUS'. (MINIMUM INSTALLED R- VALUE = 3.3) b. SOUNDUNER (OUTDOORS): 2' THICK, 1 -1/2 LB. DENSITY FIBERGLASS DUCTUNER WITH BLACK MAT FACING. SCHUU.ER- MANVILLE "PERMACOTE UNACOUSTIC STANDARD', OR OWENS CORNING 'AEROFLEX PLUS'. (MINIMUM INSTALLED R- VALUE = 7.0) c. LOW PRESSURE INSULATED FLEX DUCT: THERMAFLEX MK -E. d. HIGH PRESSURE INSULATED FLEX DUCT: THERMAFLEX MK-C. e. DUCT INSULATION (INDOORS): 1 -1/2' THICK, 3/4 LB. DENSITY FIBERGLASS WITH F.S.K. VAPOR BARKER JACKET. (MINIMUM INSTALLED R -VALUE = 3.3) f. DUCT INSULATION (OUTDOORS): 3' FIBERGLASS, MINIMUM 3/4 L.B. DENSITY, OR 2' FIBERGLASS 1.5 LB. DENSITY WITH VAPOR BARRIER AND WEATHERPROOF JACKET. (MINIMUM INSTALLED R -VALUE = 7.0) g. PERFORATED METAL 20' GAUGE COLD ROLLED STEEL WITH 3/16' DIAMETER SCOPE OF WORK 1. REPLACE EXISTING ROOFTOP GAS PACKAGED AC INTS WITH NEW. FURNISH NEW ROOF CURB PER STRUCTURAL CALCULATION ATTACHED. M.C. TO RECOMIECT DUCTWORK FROM NEW AC UNIT TO EXISTING DISTRIBUTION DUCT IN SPACE. EXISTING PROGRAMMABLE THERMOSTAT TO BE REMAIN AND COICT TO NEW AC UNIT BY M.C. EXISTING AC UNITS ARE AS FOLLOWING: RTU -1 TRANE 5 TON TRANE GAS PACKAGED AC UNIT WITH 150 MBH GAS INPUT RTU -2 TRANS 7.5 TON TRANE GAS PACKAGED AC UNIT WITH 150 MBH GAS INPUT LEGAL DESCRIPTION PARCEL NUMBER: 2623049070 POR OF if 1/4 OF SW 1/4 LY W OF CO RD DAF -BEG ON W LN OF SUBD 510 FT N OF SW COR TH N ALG W LN 255 FT TH E PLW S Ld TO W IN OF CO RD TH S ALG SD W LN 255 FT M/L TO NXN WITH LN RM1G E FRM BEG PLW S LN OF SURD TH W ALG SD PLL W TO BEG LESS ST HWY LESS E 6 F RTU -1 RTU -2 PARTIAL MECHANICAL ROOF PLAN Scale: 1/8' ®f-0" IL • MAR 3.0 2011 FILE C Permit No. .141,6"' 1 3&I Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of appro ed a';��:i±' p . d .. nditt. ns is acknowledged. By Date: City Of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. -SEPARAfPERN REQUIRED FOR: ❑,,lechanical WIectrical ❑ Plumbing ❑ Gas Piping City of Tukwila 8 h!P!C� Int���c+ir�k REVIEWED FOR CODE MPL APPROVED MAR 31 2010 A-S C. City of Tukwila 'BUILDING DIVISION ROOFTOP CONSTANT VOLUME AC UNIT SCHEDULE (GAS HEAT) ..__ .�_- • AC # MAKE TRANE MODEL YSCO60E3EHAOOD4 NOM. TONS 5 DOWNFLOW/ HORIZONTAL DOWNFLOW FACTORY CURB Y/N Y ECONOMIZER ENTERING AIR CONDENSING TEMP 'F 95 ARI EFFICIENCY COOLING CAPACITY OUTSIDE AIR CFM 200 SUPPLY FAN DATA GAS HEAT MBH ELECTRICAL WEIGHT (LBS) 617 FILTERS REMARKS 1,2,3,4 Y/N Y DB /H DB FACT. /FLD FIELD DB 75 WB 61 EER - SEER 13.0 TOTAL 55.8 SENSIBLE 51.1 CFM -' 2000 ESP 0.75 RN 1123 BHP 0.98 MHP 1.0 IN 130 OUT 104 AFUE( %) 80 VOLTS /PH 208/3 MCA 29.5 MFS 45 QTY 2 EFF. 30 SIZE 20x30x1 RTU -1 RTU -2 TRANE YSC090E3ELAO6CX 7.5 DOWNFLOW Y Y DB FIELD 75 61 95 11.2 - 81.0 69.0 300 3000 0.75 11(3 1.74 2.0 120 96.2 80 208/3 38.2 60 930 4 30 16x25x2 1,2,3,4 1: WIRING AND DISCONNECTS BY E.C. 2: SINGLE POINT POWER CONNECTION 3: FACTORY MOUNTED SMOKE DETECTORS PROVIDED WITH UNIT. 4: WEIGHT INCLUDES FACTORY ROOF CURB AND ACCESSORIES CITY MAR 2 2 2010 PERMIT CENTER M1OO PENDING CITY APPROVAL cco E CC 0 o, 3/19/10 eall ▪ m � ▪ mn °f e, • Q I ▪ 34 iL111 16° V) 13 M� Plui yX m °o d WOW 0: HOLADPI379N0 < m g • W W V) I-,z a ''' 0 0 E c 0 E N Xt o 00 c � 0 o ffs o 1- az �CC f m 0 :CC MECHANICAL LEGENDS & NOTES data of last revision: 3/19/10 trade: DRAWING DATES date: trade: date: ARCHITECTURAL S&C - ARCHITECTURAL TI - APPROVED FOR CONSTRUCTION approved: M0.01 date: cadd file name: M001