HomeMy WebLinkAboutPermit M10-042 - DIGITAL FOREST - UPS ROOMDIGITAL FOREST UPS ROOM 12101 TUKWILA INTERnATIONAL BL M10 -042 Parcel No.: Address: Suite No: Citylikf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /wwwci.tukwila.wa.us MECHANICAL PERMIT 0923049031 12101 TUKWILA INTERNATIONAL BL TUKW Permit Number: Issue Date: Permit Expires On: M10-042 04/12/2010 10/09/2010 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: DIGITAL FOREST - UPS ROOM 12101 TUKWILA INTERNATIONAL BL , TUKWILA WA INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA JARED SHEEKS 7717 DETROIT AV SW , SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU Phone: Phone: 206 768 -3806 Phone: 206 - 768 -4180 Expiration Date: 12/31/2010 DESCRIPTION OF WORK: INSTALL (2) 7.5 TON SPLIT A/C TO SERVICE NEW UPS ROOM WITH ECONOMIZERS. INSTALL SUPPLY AND RETURN DUCTWORK WITH FIRE /SMOKE AND BACKDRAFT DAMPERS PER PLANS. Value of Mechanical: $24,489.00 Type of Fire Protection: Fees Collected: $485.31 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial 0 0 0 0 0 0 2 0 0 0 0 0 0 0 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 3 Diffuser 4 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment0 * *continued on next page ** doc: IMC -10/06 M10-042 Printed: 04 -12 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.c itulcwila.wa.us Permit Number: M1O -042 Issue Date: 04/12/2010 Permit Expires On: 10/09/2010 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied xa wit Date: 1, %I ( 0 ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: � -Q. - Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M10 -042 Printed: 04 -12 -2010 Parcel No.: 0923049031 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 12101 TUKWILA INTERNATIONAL BL TUKW DIGITAL FOREST - UPS ROOM Permit Number: Status: Applied Date: Issue Date: M10-042 ISSUED 03/31/2010 04/12/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the doc: Cond -10/06 M10 -042 Printed: 04 -12 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: The UPS room to comply with International Fire Code Section 608 STATIONARY STORAGE BATTERY SYSTEMS. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -042 Printed: 04 -12 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: Y t 1 Z ( O ordinances governing or local laws regulating doc: Cond -10/06 M10 -042 Printed: 04 -12 -2010 CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION Amok Mechanical Permit No. t 0 141 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 0923049309 Site Address: 12101 TUKWILA INT'L BLVD TUKWILA, WA 98168 Suite Number: Tenant Name: P2 UPS RM - DIGITAL FOREST Property Owners Name: DIGITAL FOREST, INC. New Tenant: Floor: El Yes Mailing Address: 12101 TUKWILA INT'L BLVD #410 TUKWILA WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: JARED SHEEKS Day Telephone: (206) 768 -3806 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip E -Mail Address: JARED.SHEEKS @MACMILLER.COM Fax Number: (206) 768 -3807 MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip Contact Person: JARED SHEEKS Day Telephone: (206) 768 -3806 E -Mail Address: JARED.SHEEKS @MACMILLER.COM Fax Number: Contractor Registration Number: MACDOFS980RU Expiration Date: 12/31/2009 ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: N/A Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip Contact Person: JARED SHEEKS Day Telephone: (206) 768 -3806 E -Mail Address: JARED.SHEEKS @MACMILLER.COM Fax Number: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 1 of 2 AO Valuation of Project (contractor's bid price): $ 24,489 Scope of Work (please provide detailed information): INSTALL (2) 7.5 TON SPLIT A/C TO SERVE NEW UPS ROOM W/ ECONOMIZERS. INSTALL SUPPLY & RETURN DUCTWORK WITH FIRE /SMOKE DAMPERS AT ROOM WALLS. INSTALL RELIEF OPENING WITH FIRE /SMOKE & BACKDRAFT DAMPERS PER PLANS Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric ® Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit.Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 3 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 2 Incinerator — Comm/Ind PERMIT APPt ICATION•NOTES - • • Y • - : • 'Y... . I ...-. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ER OR AU ORIZED AGENT: Signature: iC,t(LQ �' 4 7112 Print Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW Date: 03/31/2010 Day Telephone: (206) 768 -4278 SEATTLE WA 98106 City State Zip Date Application Accepted: l (, v Date Application Expires: D I' Staff Initials: A H:\Applicotions \Forms - Applications On Line\2009 Applications \1.2009 - Mechanical Permit Application.doc Revised: 1-2009 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0923049031 Permit Number: M10-042 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 03/31/2010 Applicant: DIGITAL FOREST - UPS ROOM Issue Date: Receipt No.: R10 -00550 Payment Amount: $485.31 Initials: JEM Payment Date: 03/31/2010 12:25 PM User ID: 1165 Balance: $0.00 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2434 485.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 388.25 000.345.830 97.06 Total: $485.31 PAY ENT ECEIVE doc: Receipt -06 Printed: 03 -31 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 4-0 (II io -oyz PERMIT NO. CITY OF TUKWILA BUILDING DIVISION !'L (206)431 -3670 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Projeec/ct: LJ /6, /7A/ rC)YP� Type of Inspection: ,, / \SMdr(: -5/11 )J tht Address: 42 / U / -77_2: 6 Date Called: Special Instructions: ,41 ( I / 7 7 2 .0S Date Wanted: 7- /4/-/U ca m� rill. . Requester: Phone No: ao 6- 255 - Li/ 7S 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: d) SA, o A�.t 2/-/ i v i — e✓% 4> �,,,,,Jk flip ,/,-4,0 — #q,,,evg.sO `f' /"."1 / ap7,fat f � ,ivrf i Da e: �— /1 -/— $6 REINSPECTION FEE EQUIRED Prior to inspection, fee must be p. id at 6300 Southcenter Blv ., Suite -100. Call to schedule reinspection. R-ceipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CA Mi0 -a44 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project. Typef AA Address: `� 3.3 55 S . f2-6` pL Date Called: Special Instructions: Date Wanted: Vim, -7 _ Z -�f 0 p.m. Requester: Phone No /A — sS —3 671 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: pAti--t pri"o U pS v,t / '1--- - / f u 1 Ahr SDJih Moat__ — 2, fa tf 0 2.'.0 of 7 A-4' Li kILk El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Ins ector: Dater 2 - Q Receipt No.: Date: ..w...• .,..44._JL+..a, INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT NO. CITY of TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Mfo-o4 Project: ..�-- A: 6;M1 IF01 ( Type f In ection: i ilv e J.Acuf AT-r:0/1 Address: 12-( Date Called: Special Instructions: V. e-(9 U V (" J rrr n /i , i/H. ---- i \ ."I Date Wanted: m. /„ - ((p "(0 p.m. �.Y Requester: Phone No: 2■6(a-2.55 - -4750 Approved per applicable codes. Corrections required prior to approval. COMMENTS: = 6 : c2fr c ee ;ter t:( ti-x to I . ti Inspe,Itor: Dater I - ' 1 7- La EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD M e ( 0 .-04 min a copy with permit ''v' INS ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 0 16) = -1 .r r en--- Type of Inspection: Ad tAi t, AA ems, Address: 12(o 1 Ts-- Date Called: �-..., Special Instructions: u i)1( 2 Date Wanted: - �.m. .5-_/ 2—(o p.m. Requester: Phone No: ?,n (v -- LC-5---q VSo Approved per applicable codes. Corrections required prior to approval. COMNfENTS: ("GA. Lk/ R.wr�4n0 50)1LA- 4"C; < 0".) -v—c,. --% e--, .,r ..e.,04.- ' LL T l Date: /2 — 0.00 REINSPECTION FEE • QUIRED rior to inspection, fee must be paid at 6300 Southcenter Blve , Suit- 00. Call to schedule reinspection. Receipt No.: (Date: ego ,er.vaasa .#..... INSPECTION RECORD Retain a copy with Permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t= 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ( cYcz Proje t& � . / et _ r n l c--S'' Type nsp�ctio n: ��Ji• ff 0 Address: 1 ELI 0( -IT Date Called: Special Instructions: 0 ps S Date Wanted: — (� `100 p.m. Requester: Phone No: ?4 (Q — 2S-C-4`75-0 A pproved per applicable codes. ❑ Corrections required prior to approval. / COMMENTS: _„4111 Inspect f': 6 a Dates. 00 REINSPECTION FEE QUIRED. Pfior to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Re • t No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tz- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project rest Type oAspects ion /� -1 Address: ,_5- il-- a k-e Date Called: --4 , .o4_)L r pm cy, f7 A-1( A->"-,‘ Special Instructions: c11'(I AP_J —7-5 ,11/` .:fp P.c...P Date Wanted , j a Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ip /°/5 `, A p fir J J 4/ ,_5- il-- a k-e --4 , .o4_)L r pm cy, f7 A-1( A->"-,‘ X c11'(I AP_J —7-5 ,11/` .:fp P.c...P 2_ e.,0 - -7. S- 5,17- .517.51---cilt r t .! A I A Inspector: Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .._ • INSPECTION NUMBER INSPCTIO'N . RECORD Retain a copy with permit 10-F -cg( J1 /C)!Oja- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT • /0_ lib 444 Andover Park East, Tukwila ,Wa.98188 _ 206 -575 =4407 Project: ,kz- I 64tytr. - Type of Inspection: A &4 I AfeL,444.e,t .B1,1,6 i 1 Address: Suite #: /�lo l kl 131 Contact Person: -3'01-1., Ce f Icor Special Instructions: • Phone No.: '),5 --` `113— 4171i Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: 4 a. F - P►� i Qk Med, F.ht, t t lee-4, 0 .e. Needs Nee s Shift Inspection: Sprinklers: _ ' Fire Alarm: Hood & D uct: Monitor: • Pre -Are: Permits: Occupancy- Type: Inspector: Abeti ji -1 • • I Date: '— i Li...) 0 Mrs:: :- • n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc . 1/13/06 T.F.D. Form F.P. 113 •ERM1TCOORDC!Y • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -042 DATE: 03/31/10 PROJECT NAME: DIGITAL FOREST - UPS ROOM SITE ADDRESS: 12.101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS: uding I Ision Public Works '1VV t ( �,7 V v Fire Prevention / 1 v Planning Division Structural Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete xi Comments: Incomplete n DUE DATE: 04/01/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04/29/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LBI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Macdonald /Miller Fac Sol Inc 2067684180 Po Box 47983 Seattle Wa 98106 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254260 Active MACDOFS980RU Construction Contractor 12/31/2002 12/31/2010 General Unused n License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI*988RC Divco Incorporation Construction Contractor General Unused 12/3/2002 11/7/2010 Active MACDOMR026RU Macdonald Miller Rsdntl Inc Construction Contractor Unused General 12/31 /1998 12/31/2001 Archived MACDOMR076OP Macdonald Miller Residential Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC Divco Energy Control Company Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM *248J9 Macdonald Miller Co Construction Contractor General Unused 4/29/1976 2/1/2002 Archived ENCOMMS984CA Encompass Mechanical Services Construction Contractor General Unused 2/1/2002 2/1/2004 Expired LINFOAR980QG Linford Air &Amp; Refrigertn Inc Construction Contractor General Unused 11/7/2002 11/7/2004 Inactive DIVCOI "031L4 Divco Inc Construction Contractor General Unused 6/24/1997 8/1/2003 Relicensed Business Owner Information Name Role Effective Date Expiration Date Turley, Douglas Chief Executive Officer 02/13/2008 Turley, Douglas Chief Operating Officer 02/13/2008 Sigmund, Fredric President 12/31/2002 Hack, Richard Secretary 02/13/2008 https://fortress.wa.gov/lni/bbip/Printaspx 04/12/2010 J: \738 \6342 Digital Forest — AAON RTU UNIT NO. CU -P201 MFG & MODEL NO. TRANE TTA090D4 ARI COOL TONS 7.5 EER/ IPLV 11.2 DX AC - CONDENSING UNIT SCHEDULE NO. COMPRESSOR TYPE SCROLL CU -P202 TRANE TTA090D4 7.5 11.2 1 SCROLL NOTES: 1. COOLING PERFORMANCE IS RATED AT 95 F AMBIENT, 80 F ENTERING DRY BULB, 2. ACCESSORIES: RELIATEL CONTROLS - LONTALK COMMUNICATIONS INTERFACE - FACTORY INSTALLED CONDENSER GUARDS HP EACH RPM NO. REF CIRCUITS SUC LINE (IN) 1 -3/8 LIQ LINE (IN) ELECTRICAL VOLT /PH MCA 1 -3/8 460/3 460/3 WT CONTROL LBS NOTES 17.7 24V 24V 350 NEW 1,2 350 NEW 1,2 67 F ENTERING WET BULB AR) TES TING PROCEDURES. IN ACCORDANCE W TH S UNIT AREA _ NO. SERVED _ FCU -P201 P2 UPS ROOM FCU -P202 P2 UPS ROOM NOTES: 1. DX FAN COIL UNIT, VERTICAL UPFLOW CONFIGURATION. 2. ACCESSORIES: . PACKAGED ECONOMIZER INCLUDING DRY BULB CONTROLS (MICROMETL 0857-0200) SUBBASE, - 2" MERV -11 FILTERS. MFG & MODEL NO. TRANE TWE090D4 _____________ ________ ------ TRANE TWE090D4 DX FAN COIL UNIT SCHEDULE BLOWER CFM - ESP HP RPM 3000 I 0.5" 1 -1/2 1725 - - - -- - - -' - 3000 0.5" 1 -1/2 1725 OSA ELECTRICAL 1 HEAT CFM VOLT/PH I, LT /PH MCA VOLT /PH KW _STG 250 460/3 3.1 1 - - - 250 460/3 3.1 1 24V CONTROL WT LBS 400 400 24V NOTES NEW 1,2,3,4,5 NEW 1,2,3,4,5 3. CONTROL BY LOCAL THERMOSTAT. 4. CONNECTION TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR, UNIT TO SHUT DOWN DURING FIRE ALARM 5.' CONDENSATE PUMP REQUIRED. 120V ELECTRIC SERVICE REQUIRED BY ELECTRICAL CONTRACTOR. FITTING GENERAL NOTES PIPING INDIRECT DRAIN REFRIGERATION 1 PIPING MATERIAL SCHEDULE: SIZE MATERIAL 1/2" - 2 -1/2" 1/8" - 4 -1 /8" COPPER/DWV/TYPE M COPPER TUBE, ACR 1 JOINT LEAD FREE SOLDER BRAZED PIPING INSULATION SCHEDULE PIPING TYPE REFRIGERATION SUCTION PIPE SIZE 1/8 " -1" 1-1/8" + INSULATION TYPE FIBERGLASS, ARMAFLEX FIBERGLASS, ARMAFLEX INSULATION THICKNESS 1/2" - ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. - ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS. PROVIDE A VAPOR BARRIER COVERING ON ALL CHILLED WATER PIPING AND COIL CONDENSATE PIPING INSULATION. - PROVIDE A COVERING FOR ALL FIBERGLASS INSULATION WITHIN THE BUILDING. PROVIDE A VINYL JACKET FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING EXCEPT MECHANICAL ROOMS CONDUCTIVITY RANGE 0.23 - 0.27 0.23 - 0.27 - PROVIDE REMOVABLE LACED INSULATION PAD OVER ALL CONTROL VALVES, WHERE NOT LOCATED WITHIN A MECHANICAL ROOM. - PROVIDE ALUMINUM JACKET ON ALL INSULATED PIPING OUTSIDE BUILDING.' - AT PIPE HANGERS PROVIDE RIGID INSULATION BETWEEN PIPE AND HANGER. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 IBC, IMC, AND UPC OF WASHINGTON AND LOCAL AUTHORITIES. 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4. SLOPE ALL INDIRECT DRAINS AT 2% UNLESS OTHERWISE HERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY: BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2006 IMC AND IBC AS AMENDED BY AND LOCAL AUTHORITIES. AS AMENDED BY THE STATE THE STATE OF WASHINGTON 6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 7. PROVIDE CHROME PLATE ESCUTCHEON PLATES AT ALL EXPOSED WALL AND CEILING PENETRATIONS. 8. PROVIDE SHUT -OFF VALVES AT ALL EQUIPMENT CONNECTIONS. TO MAINTAIN 9. PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 10. FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2 "GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. PROVIDE MINIMUM 1" AIR BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 12. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR SUPPLY FOR HEAT TRACE WITH ELECTRICAL CONTRACTOR. 14. TRENCHING, BACKFILLING AND COMPACTING FOR UNDERGROUND PIPING SHALL BE THE RESPONSIBILITY UNLESS STATED OTHERWISE IN CONTRACT DOCUMENTS. COORDINATE ELECTRICAL' OF THE MECHANICAL CONTRACTOR Tuesday, March 30, 2010 6:04:36 PM SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping ►. City of Tukwila BUILDING DIVISION SYMBOL FSD -1 1> FSD -2 FSD -3 FSD -4 FSD -5 FSD -6 SD -1 SD -2 MD -1 MD -2 SCD -1 DESCRIPTION - POWERED 1 1/2 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3 -V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 212 OR EQUAL. 1 1/2 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 312 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTA L , 3 V BLADE, LEAKAGE CLASS 2, 120 V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 231 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 311 OR EQUAL. 1 1/2 HOUR TUNNEL CORRIDOR FIRE/SMOKE DAMPER: LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212 -1 OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK OF SD 212 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK VCD -23 OR EQUAL. MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL BLADES GREENHECK VCD -33 OR EQUAL. SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY GREENHECK SMD 202 OR EQUAL. SCD-2 <> SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY SCD -2 SC AIRFOIL BLADE, GREENHECK SMD 301 OR EQUAL. NOTES: 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. ' CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN /CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. - DAMPER FAILS CLOSED NOTES 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 3 4 1,2 1,2 SYMBOL FD -1 FD -2 FD -3 FD -4 FD -5 FD -4 BAR DESCRIPTION -NON POWERED NOTES 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 150 TYPE A OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 150 TYPE B OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2 TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE LINK, GREENHECK DFD -110 OR EQUAL. CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100 \\1\\ BDD (HORIZONTAL) OR EQUAL. BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) RUSKIN CBD2. NO SUBSTITUTE ALLOWED. I VOLUME DAMPER: SHOP FABRICATED, W /LOCKING QUADRANT. FELE C $ 'iPY Permit No., MID V ,2- Plan review approval is subject to errors and omissions. S not authorize rize ns I fco ructio n documents me nts doe t Approval p the violation of any adopted Receipt of approved Field Copy and conditions is acknowledged. . L-% fZi By. Date: : `. � as • �..�::.... � ��. �„ \, , ., .,, ,� „�.,; .�.,,,,•: � I SYMBOL SYMBOL DESCRIPTION ABBREVIATION SYMBOL DESCRIPTION ABBREVIATION I)-(1 GATE VALVE GV Al=1 SOLENOID VALVE SV r GLOBE VALVE GLV i GAS COCK GC X BALL VALVE - FULL PORTED N SILENT CHECK VALVE 4 BUTTERFLY VALVE BV LILT CIRCUIT SETTER VALVE CS CV Qo HORIZONTAL EXPANSION TANK HET BFV 6 = 1 L I=I VERTICAL EXPANSION TANK VET -CY BUTTERFLY VALVE W/ MEMORY STOP BFVM AIR SEPARATOR AIR SEP krvvw FLEXIBLE CONNECTION RPBP UNION 0 - -- AIR PURGER ------- - - - --- - - - - -- - - -- AP - ® REDUCED PRESSURE BACKFLOW PREVENTER CO END SUCTION CENTRIFUGAL PUMP VERTICAL IN -LINE CENTRIFUGAL PUMP ES PUMP VI PUMP UNION STRAINER STRN M -M METAL EGGCRATE SUCTION DIFFUSER SUC DIFF . P PRESSURE RELIEF VALVE RV Q TEMERATURE GAUGE TG CAP PM PRESSURE REDUCING VALVE PRV P &T COMPRESSED AIR A 14/12 Q T PRESSURE / TEMPERATURE TAP C CONDENSATE PIPING T BULB WELL BW MAV EXAMPLE OF NEW PIPING EXAMPLE OF NOT IN CONTRACT (NIC) CHWS CHILLED WATER SUPPLY - 14/12 - 1 14/12 MANUAL AIR VENT ------ - - - - -- - - -- V--T Q - -- -- -- AUTO - MATIC AIR ------ ---EN CHWR CHILLED WATER RETURN PIPING -- AV CONDENSER WATER SUPPPLY PIPING ///////7 CWS Q • • PP PRESSURE GAUGE I V-,( THERMOMETER PG CONDENSER WATER RETURN PIPING _ CWR THERM PIPING G GAS I* BALL VALVE W/ 3/4" HOSE ADAPTOR BV W/ HA CR LIQUID LINE L REFRIGERANT D CONCENTRIC REDUCER S REFRIGERANT SUCTION LINE ECCENTRIC REDUCER ER HEATING WATER SUPPLY PIPING HWS 2WAY 3WAY al ® TWO -WAY CONTROL VAVLE Ir ® THREE -WAY CONTROL VALVE HWR HEATING WATER RETURN PIPING FITTING GENERAL NOTES PIPING INDIRECT DRAIN REFRIGERATION 1 PIPING MATERIAL SCHEDULE: SIZE MATERIAL 1/2" - 2 -1/2" 1/8" - 4 -1 /8" COPPER/DWV/TYPE M COPPER TUBE, ACR 1 JOINT LEAD FREE SOLDER BRAZED PIPING INSULATION SCHEDULE PIPING TYPE REFRIGERATION SUCTION PIPE SIZE 1/8 " -1" 1-1/8" + INSULATION TYPE FIBERGLASS, ARMAFLEX FIBERGLASS, ARMAFLEX INSULATION THICKNESS 1/2" - ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. - ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS. PROVIDE A VAPOR BARRIER COVERING ON ALL CHILLED WATER PIPING AND COIL CONDENSATE PIPING INSULATION. - PROVIDE A COVERING FOR ALL FIBERGLASS INSULATION WITHIN THE BUILDING. PROVIDE A VINYL JACKET FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING EXCEPT MECHANICAL ROOMS CONDUCTIVITY RANGE 0.23 - 0.27 0.23 - 0.27 - PROVIDE REMOVABLE LACED INSULATION PAD OVER ALL CONTROL VALVES, WHERE NOT LOCATED WITHIN A MECHANICAL ROOM. - PROVIDE ALUMINUM JACKET ON ALL INSULATED PIPING OUTSIDE BUILDING.' - AT PIPE HANGERS PROVIDE RIGID INSULATION BETWEEN PIPE AND HANGER. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 IBC, IMC, AND UPC OF WASHINGTON AND LOCAL AUTHORITIES. 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4. SLOPE ALL INDIRECT DRAINS AT 2% UNLESS OTHERWISE HERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY: BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2006 IMC AND IBC AS AMENDED BY AND LOCAL AUTHORITIES. AS AMENDED BY THE STATE THE STATE OF WASHINGTON 6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 7. PROVIDE CHROME PLATE ESCUTCHEON PLATES AT ALL EXPOSED WALL AND CEILING PENETRATIONS. 8. PROVIDE SHUT -OFF VALVES AT ALL EQUIPMENT CONNECTIONS. TO MAINTAIN 9. PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 10. FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2 "GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. PROVIDE MINIMUM 1" AIR BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 12. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR SUPPLY FOR HEAT TRACE WITH ELECTRICAL CONTRACTOR. 14. TRENCHING, BACKFILLING AND COMPACTING FOR UNDERGROUND PIPING SHALL BE THE RESPONSIBILITY UNLESS STATED OTHERWISE IN CONTRACT DOCUMENTS. COORDINATE ELECTRICAL' OF THE MECHANICAL CONTRACTOR Tuesday, March 30, 2010 6:04:36 PM SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping ►. City of Tukwila BUILDING DIVISION SYMBOL FSD -1 1> FSD -2 FSD -3 FSD -4 FSD -5 FSD -6 SD -1 SD -2 MD -1 MD -2 SCD -1 DESCRIPTION - POWERED 1 1/2 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTAL, 3 -V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 212 OR EQUAL. 1 1/2 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 312 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR HORIZONTA L , 3 V BLADE, LEAKAGE CLASS 2, 120 V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 231 OR EQUAL. 3 HOUR FIRE /SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FSD 311 OR EQUAL. 1 1/2 HOUR TUNNEL CORRIDOR FIRE/SMOKE DAMPER: LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212 -1 OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK OF SD 212 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK VCD -23 OR EQUAL. MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL BLADES GREENHECK VCD -33 OR EQUAL. SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY GREENHECK SMD 202 OR EQUAL. SCD-2 <> SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY SCD -2 SC AIRFOIL BLADE, GREENHECK SMD 301 OR EQUAL. NOTES: 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. ' CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN /CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. - DAMPER FAILS CLOSED NOTES 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 3 4 1,2 1,2 SYMBOL FD -1 FD -2 FD -3 FD -4 FD -5 FD -4 BAR DESCRIPTION -NON POWERED NOTES 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 150 TYPE A OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 150 TYPE B OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2 TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE LINK, GREENHECK DFD -110 OR EQUAL. CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100 \\1\\ BDD (HORIZONTAL) OR EQUAL. BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) RUSKIN CBD2. NO SUBSTITUTE ALLOWED. I VOLUME DAMPER: SHOP FABRICATED, W /LOCKING QUADRANT. FELE C $ 'iPY Permit No., MID V ,2- Plan review approval is subject to errors and omissions. S not authorize rize ns I fco ructio n documents me nts doe t Approval p the violation of any adopted Receipt of approved Field Copy and conditions is acknowledged. . L-% fZi By. Date: : `. � as • �..�::.... � ��. �„ \, , ., .,, ,� „�.,; .�.,,,,•: � I SYMBOL DESCRIPTION SYMBOL DESCRIPTION SIZM E SHOEMAKER 701 -MA SHOEMAKER MA -DCF SYMBOL BARE SHEETMETAL I ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") SURFACE MT MODULAR CORE DIFFUSER CFM 14/12 SHOEMAKER 904 120W DOUBLE DEFLECTION SIDEWALL DIFFUSER ®CFM SOUNDLINE SHEETMETAL (1" LINING) KEES K -100 CLEANROOM QUALITY DUCTWORK T -BAR LAY -IN SLOT DIFFUSER -1" SLOTS -- - - -- -- --- - -- -- - ___ __________ ® 14/12 SL -- --------- ------- -- -- - - - -- --- ------- --- - - - TITUS ML -39 14/12 C OCFM SHEETMETAL WRAPPED W/ INSULATION (2 ") AS NOTED BARE FLAT OVAL SHEETMETAL T SHOEMAKER 905 M -M METAL EGGCRATE 14/12 W SURFACE MT RET /EXH GRILLE 14/129- RETURN /EXH BARE ROUND SHEETMETAL M -M METAL EGGCRATE FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") RETURN /EXH 120 14/12 W EXPOSED QUALITY SHEETMETAL DUCTBOARD (1" FIBERGLASS) 14/12 Q 14/12 DB EXAMPLE OF NEW EXAMPLE OF NOT IN CONTRACT (NIC) 1 - 14/12 - 1 14/12 EXAMPLE OF DEMO FLEX DUCT ///////7 EXAMPLE OF EXISTING FLEX CONNECTOR 14/1 2 3 E SCOPE OF WORK P2 UPS ROOM COOLING SYSTEMS: PROVIDE AND INSTALL (2) 7 -1/2 TON SPLIT AIR CONDITIONERS TO SERVE NEW UPS ROOM. PROVIDE WITH 100% ECONOMIZERS AND PACKAGED CONTROLS. INSTALL SUPPLY AND RETURN DUCTWORK WITH FIRE /SMOKE DAMPERS AT ROOM WALLS. PROVIDE AND INSTALL RELIEF OPENING WITH FIRE/SMOKE AND BACKDRAFT DAMPER. DAMPERS SHALL BE INTERLOCKED WITH FIRE SURPRESSION SYSTEM BY FIRE ALARM CONTRACTOR. PROVIDE AND INSTALL (2) THERMOSTATS. CONTACT LIST TITLE NAME COMPANY PHONE NUMBER E -MAIL PROJECT ENGINEER JARED SHEEKS MACDONALD MILLER 206 - 768 -3806 jared.sheeks @macmiller.com ACCOUNT EXECUTIVE SHEET METAL FOREMAN STEVE FLINK MACDONALD MILLER CHRIS HOLLINGSWORTH MACDONALD MILLER 253- 680 -3172 206 -407 -2620 steve.flink @macmiller.com Chris .hollingsworth @macmiller.com 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF "U" VALUE (BTUH /S.F. °F) = N/A WALL "U" VALUE (BTUH /S.F. °F) = N/A FLOOR "U" VALUE (BTUH /S.F. °F) = N/A GLASS "U" VALUE (BTUH /S.F. °F) = N/A GLASS SHADE COEFF. = N/A LIGHTING (WATTS /S.F.) = N/A MISC. EQUIP. (WATTS /S.F.) = N/A PEOPLE DENSITY (S.F. /PERSON) = N/A COOLING INDOOR DESIGN TEMP ( °F) = N/A COOLING OUTDOOR DESIGN TEMP F ° ( ) = N/A HEATING INDOOR DESIGN TEMP ( °F) = N/A HEATING OUTDOOR DESIGN TEMP (°F) = N/A REVIEWED FOR CODE COMPLIANCE APPROVED ita APR 0 9 2010 City o f BUILDING DIVISION 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 3, MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.) 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2006 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE /SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 14. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD ECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE AND LOCATION A PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 16. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 17. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. •• 18. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 19. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 20. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S. F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" DIMENSION). IN EITHER DI E S ( MN N. 21. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED , M T RIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 22. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 23. PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. APN # 0923049309 LEGAL DESCRIPTION: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89 -16 -35 E 100 FT TH S 24 -13 -53 E 567.42 FT TO POINT OF BEGINNING TH N 66 -35 -01 E 120.47 FT TH N 20 -23 -23 W 27.58 FT TH N 65 -32 -34 E 165 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1 -K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 110.84 FT TH FOLLOWING SAID WLY R/W LINE N 65 -32 -34 E 10 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 200 FT TH FOLLOWING SAID WLY R/W LINE N 65 -32 -34 E 20 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 126 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 65 -32 -34 W THRU C/A OF 0 -12 -18 DISTANCE OF 10.03 FT TH S 65 -30 -25 W 199.33 FT TH N 22 -47 -01 W 21.44 FT TH S 63 -32-48 W 62.13 FT TH S 65 -46 -07 W 58.17 FT TH N 24 -13 -53 W 402.19 FT TO POINT OF BEGINNING LOT C OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0033 RECORDING NO 9810059013 REVISIONS No changes shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal 71 may include additional plan review fees. 12101 IIUKWILA INTERNATIONAL BLVD TUKW LA, WA NO SCALE SITE MAP NO SCALE craruaua MAR 31 2010 PERMITCEMFfR MIouOy nL ■ Tx; C 4.3) O 0 (, < CO (O a;O N to LL U) 0) Q N 0 N. O I,- Q. E O 0 E 0 (0 E 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11111111 1 1 1 1 1 1 1 1 0 �m / , J r Z W 0 0w Z _J U) QgQ 0 _ ENGINEER: 0 N � ENGINEER: J SHEEKS CHECKED BY: B GEZON WA Lic No: MACDOFS980RU 0 w 0 w 3 W Q 0 REVISIONS: w 0 REVISIONS: REVISED: -31 -10 - DATE PLOTTED: CAD: R VILLANUEVA 03 -31 -10 ISSUE DATE: DRAWING NUMBER: 0-1490- 7306210 -00 SHEET NUMBER: TM0.01 SYMBOL MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES SIZM E SHOEMAKER 701 -MA SHOEMAKER MA -DCF AS NOTED AS NOTED T -BAR LAY -IN MODULAR CORE DIFFUSER I 0 CF SIZE SURFACE MT MODULAR CORE DIFFUSER CFM SHOEMAKER 904 AS NOTED DOUBLE DEFLECTION SIDEWALL DIFFUSER ®CFM : KEES K -100 AS NOTED - -- - - -- --- - - - - -- AS NOTED T -BAR LAY -IN SLOT DIFFUSER -1" SLOTS -- - - -- -- --- - -- -- - ___ __________ ® - -- --------- ------- -- -- - - - -- --- ------- --- - - - TITUS ML -39 ----- - SURFACE MT SLOT DIFFUSER -1" SLOTS OCFM SHOEMAKER RD AS NOTED ROUND CEILING DIFFUSER OCFM SHOEMAKER 905 M -M METAL EGGCRATE AS NOTED 12/24 SURFACE MT RET /EXH GRILLE ON RETURN /EXH M -M METAL EGGCRATE 24/24 RETURN /EXH SCOPE OF WORK P2 UPS ROOM COOLING SYSTEMS: PROVIDE AND INSTALL (2) 7 -1/2 TON SPLIT AIR CONDITIONERS TO SERVE NEW UPS ROOM. PROVIDE WITH 100% ECONOMIZERS AND PACKAGED CONTROLS. INSTALL SUPPLY AND RETURN DUCTWORK WITH FIRE /SMOKE DAMPERS AT ROOM WALLS. PROVIDE AND INSTALL RELIEF OPENING WITH FIRE/SMOKE AND BACKDRAFT DAMPER. DAMPERS SHALL BE INTERLOCKED WITH FIRE SURPRESSION SYSTEM BY FIRE ALARM CONTRACTOR. PROVIDE AND INSTALL (2) THERMOSTATS. CONTACT LIST TITLE NAME COMPANY PHONE NUMBER E -MAIL PROJECT ENGINEER JARED SHEEKS MACDONALD MILLER 206 - 768 -3806 jared.sheeks @macmiller.com ACCOUNT EXECUTIVE SHEET METAL FOREMAN STEVE FLINK MACDONALD MILLER CHRIS HOLLINGSWORTH MACDONALD MILLER 253- 680 -3172 206 -407 -2620 steve.flink @macmiller.com Chris .hollingsworth @macmiller.com 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF "U" VALUE (BTUH /S.F. °F) = N/A WALL "U" VALUE (BTUH /S.F. °F) = N/A FLOOR "U" VALUE (BTUH /S.F. °F) = N/A GLASS "U" VALUE (BTUH /S.F. °F) = N/A GLASS SHADE COEFF. = N/A LIGHTING (WATTS /S.F.) = N/A MISC. EQUIP. (WATTS /S.F.) = N/A PEOPLE DENSITY (S.F. /PERSON) = N/A COOLING INDOOR DESIGN TEMP ( °F) = N/A COOLING OUTDOOR DESIGN TEMP F ° ( ) = N/A HEATING INDOOR DESIGN TEMP ( °F) = N/A HEATING OUTDOOR DESIGN TEMP (°F) = N/A REVIEWED FOR CODE COMPLIANCE APPROVED ita APR 0 9 2010 City o f BUILDING DIVISION 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 3, MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.) 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2006 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE /SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 14. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD ECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE AND LOCATION A PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 16. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 17. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. •• 18. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 19. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 20. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S. F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" DIMENSION). IN EITHER DI E S ( MN N. 21. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED , M T RIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 22. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 23. PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. APN # 0923049309 LEGAL DESCRIPTION: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89 -16 -35 E 100 FT TH S 24 -13 -53 E 567.42 FT TO POINT OF BEGINNING TH N 66 -35 -01 E 120.47 FT TH N 20 -23 -23 W 27.58 FT TH N 65 -32 -34 E 165 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1 -K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 110.84 FT TH FOLLOWING SAID WLY R/W LINE N 65 -32 -34 E 10 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 200 FT TH FOLLOWING SAID WLY R/W LINE N 65 -32 -34 E 20 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 126 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 65 -32 -34 W THRU C/A OF 0 -12 -18 DISTANCE OF 10.03 FT TH S 65 -30 -25 W 199.33 FT TH N 22 -47 -01 W 21.44 FT TH S 63 -32-48 W 62.13 FT TH S 65 -46 -07 W 58.17 FT TH N 24 -13 -53 W 402.19 FT TO POINT OF BEGINNING LOT C OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0033 RECORDING NO 9810059013 REVISIONS No changes shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal 71 may include additional plan review fees. 12101 IIUKWILA INTERNATIONAL BLVD TUKW LA, WA NO SCALE SITE MAP NO SCALE craruaua MAR 31 2010 PERMITCEMFfR MIouOy nL ■ Tx; C 4.3) O 0 (, < CO (O a;O N to LL U) 0) Q N 0 N. O I,- Q. E O 0 E 0 (0 E 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11111111 1 1 1 1 1 1 1 1 0 �m / , J r Z W 0 0w Z _J U) QgQ 0 _ ENGINEER: 0 N � ENGINEER: J SHEEKS CHECKED BY: B GEZON WA Lic No: MACDOFS980RU 0 w 0 w 3 W Q 0 REVISIONS: w 0 REVISIONS: REVISED: -31 -10 - DATE PLOTTED: CAD: R VILLANUEVA 03 -31 -10 ISSUE DATE: DRAWING NUMBER: 0-1490- 7306210 -00 SHEET NUMBER: TM0.01 z J: \738 \6342 Digital Forest — P2 UPS ROOM SPLIT AIR CONDITIONERS: SYSTEM DESCRIPTION: THE P2 UPS ROOM IS SERVED BY TWO SPLIT AIR CONDITIONERS PROVIDED WITH 100% OSA ECONOMIZERS. INITIALLY, THE A/C UNITS WILL BE CONTROLLED WITH STAND ALONE THERMOSTATS. IN THE FUTURE, THE SYSTEMS WILL BE TIED INTO THE BUILDING DIGITAL CONTROL SYSTEM. SCHEDULE OF OPERATION: THE UPS ROOM IS A 24/7 OPERATION. THERE SHALL BE NO TEMPERATURE SETBACK. LEAD /STANDBY: THE UNITS SHALL BE OPERATED IN A LEAD /LAG ARRANGEMENT. PRIOR TO CONNECTON TO THE DDC, THE THERMOSTATS SHALL BE PROGRAMMED SUCH THAT THE SUPPLY FAN OF THE LEAD UNIT RUNS CONTINUOUSLY. THIS UNIT PROVIDES FIRST STAGE COOLING. THE SUPPLY FAN OF THE LAG UNIT SHALL BE SET IN AUTO MODE, SO THAT IT ONLY RUNS WHEN COOLING IS ENGAGED. AFTER CONNECTION TO THE DDC, THE UNITS SHALL BE SETUP IN TRUE LEAD/LAG FASHION, WHERE ONLY ONE UNIT RUNS AT A TIME AND THE LEAD UNIT IS ALTERNATED ON A REGULAR BASIS. SUPPLY FANS: THE SUPPLY FAN OF THE LEAD UNIT SHALL RUN CONTINUOUSLY. THE SUPPLY FAN OF THE LAG UNIT SHALL BE SET TO INTERMITTENT MODE SUCH THAT IT IS ONLY ON WHEN COOLING IS ENGAGED. AFTER CONNECTION TO THE DDC, THE UNITS WILL BE SET IN A TRUE LEAD /LAG ARRANGEMENT, WHERE ONLY ONE UNITS FAN OPERATES AT ANY TIME. TEMPERATURE CONTROL: THE ECONOMIZER AND DX COOLING OPERATE TO MAINTAIN THE ROOM TEMPERATURE AT SETPOINT, AS SENSED IN THE RETURN AIR DUCT (1 SENSOR PER UNIT). PRIOR TO CONNECTION TO THE DDC, THE LEAD UNIT SHALL HAVE A COOLING SETPOINT 4 DEGREES BELOW THE LAG UNIT (INITIALLY SET AT 800). COMPRESSORS: MECHANICAL COOLING SHALL BE ENABLED BY THE PACKAGED ECONOMIZER CONTROLS. IF OUTSIDE AIR IS NOT SUFFICIENT TO COOL THE UPS ROOM, THE PACKAGED CONTROLS WILL ENABLE THE COMPRESSOR OF EACH UNIT. ECONOMIZER: PACKAGED 100% OSA ECONOMIZERS ARE PROVIDED ON EACH UNIT. AN ECONOMIZER CONTROLLER ON EACH UNIT MEASURES THE OUTSIDE AIR AND MIXED AIR TEMPERATURE AND MODULATES THE OUTSIDE AIR AND RETURN AIR DAMPERS TO MAINTAIN SPACE TEMPERATURE. IF THE ECONOMIZER CONTROLLER DETERMINES THAT OUTSIDE AIR IS NOT SUFFICIENT TO MAINTAIN SPACE TEMPERATURE, IT WILL ALLOW MECHANICAL COOLING. CONNECTION TO FIRE ALARM SYSTEM: THE UNITS SHALL BE INTERLOCKED WITH THE FIRE ALARM SYSTEM BY THE ELECTRICAL CONTRACTOR. DURING AN ALARM EVENT, THE UNITS SHALL SHUT DOWN. FIRE/SMOKE DAMPERS: THE FIRE/SMOKE DAMPERS SHALL BE INTERLOCKED TO THE FIRE ALARM SYSTEM BY THE ELECTRICAL CONTRACTOR. DURING AN ALARM EVENT, THE FIRE ALARM SYSTEM SHALL CAUSE THE DAMPERS TO CLOSE. ALARMING: AFTER CONNECTION TO THE DDC, A HIGH TEMPERATURE ALARM SHALL BE PROGRAMMED TO ALARM IF THE RETURN TEMPERATURE EXCEEDS 85 DEGREES (ADJUSTABLE). - REV COMPL FOR CODE APPROVED APR 0 9 2010 City of Tukwila BUILDING DIVISION 0 0 0 CO CO CO D N N- Ct CI ~ co N N N X O LL CO• lii0 O CO 0 c� E O o - 0 • N • O ,+ tia 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 M N w F. x w W 0 REVISIONS: W 0 REVISIONS: Tuesday, March 30, 2010 6:06:11 PM P110 O'1Z MAR 31:2010 RCEfdI'ER ENGINEER: J SHEEKS CHECKED BY: B GEZON CAD: R VILLANUEVA LAST REVISED: 03 -31 -10 DATE PLOTTED: 03 -31 -10 ISSUE DATE: DRAWING NUMBER: 0-1490- 7306210 -00 SHEET NUMBER: TM0.02 J: \738 \6342 Digital Forest — AAON RTU Tuesday, March 30, 2010 6:05:47 PM _ ...... • _ •• PULL SECT CT 400 PIM" CT 2000r+ SECT 2000A i i. ,300jic 3000A 1200P 1- ------------------ _ 111:111 I I III 1 -.1 0 ( 4 ) ( 5 ) L I I L /It •-•II .. _ 24"x24" SUPPLY REGISTER SHOEMAKER 600P WITH OBD & PERF FACE 750 CFM (TYP 4) OBD BLADES PARALLEL TO DUCT I 1 ! I • ••.; I INTERLOCK FSD WITH FIRE SUPPRESSION SYSTEM (BY ALARM CONTRACTOR) (TYPICAL) 6 ) FIELD ROUTE CONDENSATE TO APPROVED RECEPTOR FCU-P201 MOUNT FCU ON NEOPRENE PADS UPS & BATTERIES 30/16 BDD TYPICAL FCU-P202 ; PACKAGED UPS ROOM ECONOMIZER BOX MICROMETL I 0857-200U) ; (TIPICAO MINIMUM OSA = 250 CFM BIRDSCREEN OVER OPNG BDD (FYP I CAL) 42/14 R/A OPNG W/ BAR GRILLE MOUNT HIGH (TYPICAL) , ... ..... 56"x16" RELIEF OPNG HIGH W/ FSD ( UPTURNED BLADE LOUVER 13c GREENHECK ESU -130 APPROXIMATE DISTANCE TO FACE OF UNIT 4'-23/4" ------- — ---------- ===== & BOLT TO CONCRETE PAD (TYPICAL) 16/30 SL 2 ; DISCONNECT (BY ELECTRICAL) ! I 4" HOUSEKEEPING PAD (BY OTHERS) I . 1--- — --- (TYPICAL) _. . . 1 CHAIN LINK FENCE --(BY-OTHERS) I 1 1 CONDENSATE PUMP (TYPtCAL)- BOLLARD (BY OTHERS). _ FIELD ROUTE CONDENSTE'ITO-' APPROVED RECEPTOR ' 5)/4" APPROXIMATE DISTANCE TO EDGE OF PAD APPROXIMATE DISTANCE TO FENCE • II 5/8" LIQUID (TIP 2) 1-3/8" SUCTION (TYP 2) ELECTRICAL CONDUITS (BY ELECTRICAL) CU-P201 CU-P202 (71. .• 1---`.1_,', 1 HT I • .• I •' 1 ! --!•/---.71-.7!: 1 I n 7.5 ) ( 8 ) REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 9 2010 City of Tukwila 1 BUILDING DIVISION 1 I-I...A •1 RCOlvi GEN ERA< . `'• - • ' • • . .1.1 ' • 'I.:: I 2Ax!--_,,„--,,!,......,..........„.!---, !!!„-:!.---, , 1 1 A ,:,------ 1 im 'I1 ,f 14_ _, N \ 1_4_ _,_ /11 11,11,-- i 1 1.4 1 / \ 1 1 1:11 od / , , \ 0 1 / i--_---.E.-f, , 1,1 1 i 1 1 1 \ , 1 / I \ ' 1 d i I \ , ,,,I \i• • __I II 1 1 \ 1111 II, I I lo, 4" HOUSEKEEPI \IG PAD 1 Lts----- - ---- II 0 id:■/■%,:,,,.._,../__..; i-:::: t'_5' ,"‘ 11, III'l ,.„ I:IP (BY OTHERS),// H— 1 1 --::::::::_—'=---f-±.trr:iff::::JL-_=•:'::::::_:•::::dt-_-.7.±...t-,1---', l l ) HIT 'Il' '4- 1 ., ,--,--,,, - il::::L i- BOLLc■RD1 (BY OTH TS) (TYP) .. Pk_11 0 92/32 CONDENSER DUCT W/ RADIUS ELBOW EXTEND TO WALL OPNG MIO (A' B E CITMatit MAR 3 1 2010 PERMIT CENTER 1/8" = 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ENGINEER: J SHEEKS CHECKED BY: B GEZON CAD: J SHEEKS DRAWING NUMBER: MMA WA Lic No: MACDOFS980RU Ld 0 REVISIONS: IJ 0 REVISIONS: w 0 0 0 w LAST REVISED: 03-31-10 DATE PLOTTED: 03-31-10 ISSUE DATE: C-1490-7306210-00 SHEET NUMBER: TM1 .02