HomeMy WebLinkAboutPermit M10-046 - UNITED STATES POST OFFICEUNITED STATES POST OFFICE 225 ANDOVER PK W EXPIRED 06-24-11 M10 -046 City PI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 9202470010 Address: 225 ANDOVER PK W TUKW Project Name: UNITED STATES POST OFFICE Permit Number: M10 -046 Issue Date: 06/18/2010 Permit Expires On: 12/15/2010 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: TIM MALCOLM Address: 835 N CENTRAL AVE #132 , KENT WA 98032 Email: TMALCOLM @ACCOES.COM Contractor: Name: ACCO ENGINEERED SYSTEMS INC Address: 6265 SAN FERNANDO RD , GLENDALE CA 91201 Contractor License No: ACCOESI971DU Phone: 253- 261 -7184 Phone: (818)244 -6571 Expiration Date: 10/13/2011 DESCRIPTION OF WORK: REMOVE FAILED ROOFTOP PACKAGE UNIT & INSTALL A NEW RTU IN IT'S PLACE. LIKE FOR LIKE. Value of Mechanical: $14,259.00 Type of Fire Protection: Permit Center Authorized Signature: Fees Collected: $362.81 International Mechanical Code Edition: 2009 Date: d ri /v I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p-rformance of work. I am authorized to sign and obtain this mechanical permit. Sicnlature: Print Name: A.. Air AM' Date: / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -046 Printed: 06 -18 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Tenant: 225 ANDOVER PK W TUKW UNITED STATES POST OFFICE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10-046 ISSUED 04/06/2010 06/18/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents Shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) doc: Cond -10/06 M10 -046 Printed: 06 -18 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: In areas that are not continuously occupied, automatic smoke detection shall be provided at each fire control unit(s) location to provide notification of fire at that location. (NFPA 72) 18: An approved fire alarm system is required per City Ordinance ( #2051) An approved automatic sprinkler system may be installed in lieu of a fire alarm system. (Plans must be submitted to the Fire Prevention Bureau for approval prior to installation.) (City Ordinance #2051) (IFC 104.2) 19: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 20: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 23: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10-046 Printed: 06 -18 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: di doc: Cond -10!06 M10 -046 Printed: 06 -18 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://vvww.ci.tukwila.wa.us Mechanical Permit No. Nit 10" C q , Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: -5— / OL/r0 (I" Tenant Name: V King Co Assessor's Tax No.: q 2- 47 -0010 Suite Number: Floor: New Tenant: ❑ Yes .No Property Owners Name: t t )t r !��� „Lk L Mail' Address: C TACT PERSON - Who do we contact when your permit is ready to be issued cif %err + S Zip Name: Mailing Address: E -Mail Address: /41 .9 /c>_o%r7 M. Day Telephon City to Zip Fax Numbeb2 — S — ) MECHANICAL CONTRACTOR INFORMATION Company Name: /4 C!.C?.f.) Mailing Address: — . i, e Contact Person: 77 h`/ E -Mail Address: Y 1% (1L/ .1 t vt Contractor Registration Number: —410 City State Zip Day Telephone:, S 3— 8 - 9 -Y Fax Number: 3 —R5 Y.28, (, Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Ws.ApplscaUOns\smtns- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised 1 -2009 bh Page 1 of 2 • • Valuation of Project (contractor's bid price): $./' / Scope of Work (please provide detailed information): / /I. %c 1.21/147-___72,L1/ i,1 S /T / P.:71j 14) / r-5 / F- J) ) Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas pi Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 1 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment / "Pror -'Top IA,. i j Air Handling Unit <10,000 CFM Incinerator - Comm/Ind /„20 ccs 41Th # Ac J PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAIVIINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. B !'t I ING O S gnC- OR AUTHORIZED A - T: Print Name: 77. Mailing Address: ,07,0/e119-4, AZ—t/ it Date: 3 -AO/ Day Telephonel'23 _h'/ — 7/33 >1- 3 ?— City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:MpplicationstFomis- Applications On Ltne12009 Apphcanonsll -2009 - Mechanical Permit Apphcation.doc Revised: 1 -2009 Wi Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 225 ANDOVER PK W TUKW Suite No: Applicant: UNITED STATES POST OFFICE RECEIPT Permit Number: M10 -046 Status: APPROVED Applied Date: 04/06/2010 Issue Date: Receipt No.: R10 -01100 Initials: LAW User ID: 1632 Payment Amount: $290.25 Payment Date: 06/18/2010 01:41 PM Balance: $0.00 Payee: ACCO ENGINEERED SYSTEMS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 006864 290.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 290.25 Total: $290.25 doc: Receiot -06 Printed: 06 -18 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 225 ANDOVER PK W TUICW Suite No: Applicant: USPS RECEIPT Permit Number: M10 -046 Status: PENDING Applied Date: 04/06/2010 Issue Date: Receipt No.: R10 -00581 Payment Amount: $72.56 Initials: WER Payment Date: 04/06/2010 02:15 PM User ID: 1655 Balance: $290.25 Payee: TIMOTHY MALCOT TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 001061 ACCOUNT ITEM LIST: Description 72.56 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 72.56 Total: $72.56 doc: Receipt -06 Printed: 04 -06 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION E' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Typ f Inspection: Address: %_S dQ J u Date Called: r _ j 4, AA.P cf-x Special Instructions: '� ) i .; el — d Date Wanted: -l� �,`a.m� '7Ci Requester: Phone No: 2S3 -2-Col 7Z,30 Approved per applicable codes. � Corrections required prior to approval. COMMENTS: 0) tiac:lo-kric,0( - 7),e>4-,,•-• r.l . eJ -- t•J e r ec - - Par, i 1. b Tom, G. k 1.3 /, i t ,Is9. OfP '',rC 1-� 10i- ►J4 41 SIY`0 I LE 1**,- i s J t3 — Rog day,/ �s"M` -' NI ( ,rA(' 2 f \� (� c)k,. -. ' J - �,L� J'°.'C' Inspect r r+. . j. J $ • 0.0 i REINSPECTIO FEE R QUIRED. Pri id - 6300 Southcenter Blvd:, uite 10 p Date x24 —� r to inspection, fee must be Call to schedule reinspection. Recei . No.: Date: Google Maps Google maps Page 1 of 1 Save trees. Go green! Download Google Maps on your phone at google.com /gmm o chancesshall;be1.r ade to thesscopP? sr of work withoutiprior4'approv0l1of .may r ��t,� Tukwila,Bullding D�vlsion NOTE Rev sons wlll require'aan L Fpl�n submatta lnct�ldesatltf,tconalPpii nra SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical 61 Electrical Plumbing Gas Piping City of Tukwila LE34..m...0IP_iG DIVISION FILE COPY Permit No. At 0 ii Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of , = d y and conditions is acknowledged: By Date: jr-/T I 0 City Of Tiukwila BUILDING DIVISION r1IO 01-I tO REVIEWED FOR CODE COMPLIANCE APP ovED APR 15 2010 City o kwila RI IILDING III /IPIAI ECEWVE APR 0 6 2010 PERMIT CENTER http:// maps.google.com/ ?ie= UTF8 &11 =47. 456622, - 122.254969 &spn = 0,359.998281 &t= h &z... 4/5/2010 $21l4'20 l i Ctoriale: lii tiger 02o 10 harms [rse * Report a problem rK ECE VED APR 0 6 2010 PERMIT CENTER 225 Andover Park West Tukwila, WA - Google Maps Page 1 of 1 Goog le maps Address 225 Andover Park W Tukwila, WA 98188 IGet Google Maps on your phone Text the word "GMAPS" to 466453 i 1; I ; US Post Office Key Bank a 1 02010 Google - Map data 02010 Google - ECEIVED APR 06 2010 PERMIT CENTER http://maps.google.com/maps?f=q&souree=s_q&h1=en&geocode=&q=225+Andover-FPark... 4/5/2010 • -To tookt . gab -61". ECEIVE APR 0 6 2010 PERMIT CENTER Project -Untitled7 Prepared By: Unit Report For Untitled1 02/02/2010 09:55AM Unit Parameters Unit Model: 48TCEDO8A2G5-0A0A0 Unit Size: 08 (7.5 Tons) Volts- Phase - Hertz: 208-3-60 Heating Type: Gas Duct Cfg: Horizontal Supply / Horizontal Return Heating Capacity: Medium Heat Unit Configuration Medium Static Option Al/AI - Al /Cu Electro-mechanical controls Standard Dimensions (ft. in.) & Weight (lb.) *** Unit Length: T 4.125" Unit Width. 4' 11.5" Unit Height' 3' 5.25" Base Unit Weight 935 lb ** Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Warranty Information First Year - Parts Only (Standard) No optional warranties were selected. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Ordering Information L copy Part Number Description Quantity 48TCEDO8A2G5 -OA0A0 Rooftop Unit R-410A 2 -stage 1 Accessories 0849-0200 -9J930 Horizontal Economizer with solid -state controller 1 33CS2PP2S -01 Thermostat 1 t1Io'm REVIEWED FOR CODE COMPLIANCE APPROVED APR 15 2010 City of Tukwila BUILDING minim' RECEIVED APR 0 6 2010 PERMIT CENTER Packaged Rooftop Builder 1.19q Page 1 of 5 Project: - Untitled7 Prepared By: Certified Drawing for Untitled1 02/02/2010 09:55AM I NOTES: 1. DIMENSIONS ARE IN INCHES, DININENSIONS IN 1 I ARE IN MILLIMETERS. 2. S CENTER OF GRAVITY 3 DIRECTION OF AIR FLOW UNIT I N H ADTC-A08 41 1/4 110481 33 16581 15 7/8 [4031 487C409 49 3/8 112531 37 1/4 19461 23 1/8 [6091 481C -Al2 49 3/8 112531 37 1/4 19461 15 1/a [4031 481C -D08 41 1/4 110461 33 (6581 15 1/8 (4031 481C-012 49 3/8 112531 37 1/4 19461 15 7/8 [4031 . - FOR TIC TALE COOLING MODELS WITH NOVATION CONDENSER COILS FILTER ACCESS PANEL ITOOL-LESSI • CONDENSER COIL INDOOR COIL ACCESS PANEL OPTIONAL •, 3 -3/4 (951 BACK CONDENSER COIL A. D. G OPTIONAL •, FACTORY 1- INSTALLED 37 19401 NN I/6 CONVENIENCE E OUTLET - _ -- F 4 -S /8 11181 Jr 40 3/a 110261 UNITED A.D. WI Not TECHNOLOGIES I1fa01[. II CARRIER 11021 IMO DOCUMENT IS TMl f2OPO11 P CARVE CORONATION AND II DELIVERED UPON Tilt EPEES! CONDITION THAT Tilt CONTENTS WILL NOT DI DISCLOSED ON USED N11NM C1NICR CORPONATIUI•I PITT. 0011000. 3®NI6110R 01 TNTIE DIAl1RG1 CI OOC N(IT1 O N 101 CDIITANCEF PANT TRACT. CE n ACCEPTANCE P CUNTRACT. 20.3/4 [5271 12 -5/8 13211 18 16 (1691 [1121 13551 11 1 i 12191 E ALT. CONDENSATE RAIN OPENING IN BASEPAN ■ ISO Ll \'m/L h77 /Ilil ILLVAAAAA'- -'%'9 1/ /41 37.518 [9551 RETURN AIR 40 -318 110271 SUPPLY AIR LECTR ICAL DISCONNECT LOCATION 27 -7/8 17091 6 -5/8 11681 59 1/2 115101 LEFT 2.5I 1671 TIP CURB WIDT 265/8 [1511 11001 TOP LUE HOOD 14 13561 25 1/2 16471 (22351 FRONT 3.1/4 1831 L 6 -I/4 11591 CONTROL BOX ACCESS PANEL OPTIONAL- FACTORY INSTALLED DISCONNECT • F HANDLE-mod INDOOR BLOWER ACCESS !--HANDLE • D o 'cam `= . o 8 H 1- L 6-3/8 12141 37 19401 NN I/6 (22351 FRONT 3.1/4 1831 L 6 -I/4 11591 THRU- THE-RASE CHART THESE HOLES REO [RED FOR USE CRBTMP6R002A0 , 004A01 THREADED CONDUIT SIZE WIRE USE REO'O HOLE SIZES IMAX.1 1/2' ACC. 7/8' 122.21 I/2' 24V I /8' 122.2/ 1 1/4' 1002.0041 POWER 1 3/4' 144.41 21 10041 3/4' FPT GAS 15/8' 141.31 FOR ' THRU-THE-BASEPAN' FACTORY OPTION!, FITTINGS FOR ONLY X, Y, I. ARE PROVIDED FOR HEAT SIZES 'D' 6 'S' • A FIELD SUPPLIED 1/2' ADAPTER IS REQUIRED BETWEEN BASE PAN FITTING AND GAS VALVE. 10021 PROVIDES 3/4' FPT THRU CURB FLANGE 6 FITTING. OUTSIDE 26 AIR 16 91 SUPPLY AIR I, [10751 RETURN RIGHT AIR BAROMETRIC RELIEF FLOW SMUT 1 OF 2 DATE 09/29/08 AUPIED0EI 08 -29 -08 48TC 08 -12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500985 NON 4.0 Packaged Rooftop Builder 1.19q Page 2 of 5 CONNECTION SIZES A 1 3/8' DIA [351 FIELD POWER SUPPLY HOLE B 2 1 /2' 1641 DIA POWER SUPPLY KNOCKOUT C 1 3/4' DIA IS11 GUAGE ACCESS PLUG D 7/8' DIA 1221 FIELD CONTROL WIRING HOLE E 3/4' -14 NPT CONDENSATE DRAIN 1/2'-14 NPT GAS CONNECTION F 3/4' -14 NPT GAS CONNECTION 6 2 ' DIA [511 POWER SUPPLY KNOCK-OUT THRU- THE-RASE CHART THESE HOLES REO [RED FOR USE CRBTMP6R002A0 , 004A01 THREADED CONDUIT SIZE WIRE USE REO'O HOLE SIZES IMAX.1 1/2' ACC. 7/8' 122.21 I/2' 24V I /8' 122.2/ 1 1/4' 1002.0041 POWER 1 3/4' 144.41 21 10041 3/4' FPT GAS 15/8' 141.31 FOR ' THRU-THE-BASEPAN' FACTORY OPTION!, FITTINGS FOR ONLY X, Y, I. ARE PROVIDED FOR HEAT SIZES 'D' 6 'S' • A FIELD SUPPLIED 1/2' ADAPTER IS REQUIRED BETWEEN BASE PAN FITTING AND GAS VALVE. 10021 PROVIDES 3/4' FPT THRU CURB FLANGE 6 FITTING. OUTSIDE 26 AIR 16 91 SUPPLY AIR I, [10751 RETURN RIGHT AIR BAROMETRIC RELIEF FLOW SMUT 1 OF 2 DATE 09/29/08 AUPIED0EI 08 -29 -08 48TC 08 -12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500985 NON 4.0 Packaged Rooftop Builder 1.19q Page 2 of 5 Project: - Untitled? Prepared By: Certified Drawing for Untitled1 02/02/2010 09:55AM UNIT STD. UNIT WEIGHT CO NER WEIGHT III CORNER WEIGH1 181 CORNER WEIGHT (C) CORNER WEIGHT (DI C.G. = L85. KG. 162. KG. LBS. KG. 183. KG. LBS. KG. 0 T • 2 I 480C-A08 810 367 171 78 164 11 233 106 241 110 41 1/8 11064) 33 7/8 (8401 20 1/4 1516) 46TC •A09 910 413 193 88 181 82 260 116 276 125 41 3/8 11051) 22 7/8 (5811 22 7/8 1581) 4800-412 365 438 201 94 204 13 215 125 279 121 42 3/8 11076) 24 U8 (6131 24 1/8 1613) 48TC-008 660 390 153 69,3 141 68.6 213 124 284 129 42 3/4 11088) 31 1/2 (9541 20 1/8 1512) 481C-D12 140 426 196 88.9 190 66.2 211 123 219 121 42 110671 33 7/6 (8621 20 1/4 1513) CORNER A SCALE I:0 FRONT C UNITED T.D. III u99 TECHNOLOGIES 37330951. 07 CARRIER MD TICS =MIT IS TIE 73000377 0 03131[1103WIATEO 101 IS 00.lVElE0 0003 TM MUSS CONDITION TUT TIE 000(01(3 PUT 101 BE 01301000 01 2010 IITIOIIT 1A111E1 30000947E01 3311101 00113011. 3W333117 00337771103PI111161 00A1IOCAICI 1113 3001072/01 00 0071107. CORNER B CORNER C S12ET 2 o 2 DOE 09/29/08 98701012(8 08 -29 -08 48TC 08 -12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500985 IEV 4.0 Packaged Rooftop Builder 1.19q Page 3 of 5 • = X • Il(i100 w ~I • 1 I I : 000 FRONT C UNITED T.D. III u99 TECHNOLOGIES 37330951. 07 CARRIER MD TICS =MIT IS TIE 73000377 0 03131[1103WIATEO 101 IS 00.lVElE0 0003 TM MUSS CONDITION TUT TIE 000(01(3 PUT 101 BE 01301000 01 2010 IITIOIIT 1A111E1 30000947E01 3311101 00113011. 3W333117 00337771103PI111161 00A1IOCAICI 1113 3001072/01 00 0071107. CORNER B CORNER C S12ET 2 o 2 DOE 09/29/08 98701012(8 08 -29 -08 48TC 08 -12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500985 IEV 4.0 Packaged Rooftop Builder 1.19q Page 3 of 5 I1/IH/TTAI FORM NO. 2502 -7P SUBMITTED TO COMPANY. DRAWN BY JOB NAME' EQUIPMENT. NOTES: M. HARGIS Horizontal economizer with built -in relief damper for 48/50 TF, TFQ, HJQ,TJ,HJ TJQ, GJ, TM 004 -014 Units Part Number: 0849 Series FEATURES: • Gear driven dampers, eliminates slippage associated with standard linkage. • Factory assembled hood. • Direct coupled actuator. • Low static pressure loss through economizer. • 100% barometric relief capability. • Top of hoods are sloped to allow for water run -off. • Hoods are constructed of pre paint steel, matching the finish of the HVAC unit. Water entrainment filter provided. Horizontal E . nomizer ctuator E omizerincludes eywellW7212 roller with CO2, control and power haustcontra Carrier Units MicroMeti Economizer No. 004 -007 0849 -0101 008- 014 0849 -0201 Filterdoor 24 3/4" Static Pressure Drop through Dampers - in w.g. 0849 -0101 0849 -0201 CFM 1200 1600 2000 2400 2800 3000 3400 4000 5000 Return Air 0.055 0.088 0.14 0.22 0.11 0.14 0.17 0.25 0.36 Outside Air 0.024 0.043 0.073 0.096 0.10 0.11 0.15 0.20 0.31 Outside air / relief air hood 1. Return air test performed with outside air damper 100% closed. 2. Relief air and outside air test performed with return airdamper 100% closed. NOTE A: This horizontal blank off is shipped with the 0849 -0201, but is only used on the taller 8 1/2, 10, 12 1/2 ton units. NOTE B: This panel extender is shipped with the 0849 -0201, but is only used on the taller 8 1/2, 10, 12 1/2 ton units. If using the 0849 -0101 with the taller HJ007, the optional 0840 -0100 -FRBO panel must be ordered. THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MICROMETL 3035 NORTH SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS, IN 46226 • 1- 800-662-4822 •• MICROMETL WEST 202 SOUTH 18TH ST. • SPARKS, NV 89431 • 1- 800 -884 -4662 Project —Untitled7 Prepared By: Performance Summary For Untitledi 02/02/2010 09:55AM Part Number:48TCEDO8A2G5 -0A0AO ARI EER. 11.00 IEER: 11.7 Base Unit Weight 935 lb Base Unit Dimensions Unit Length: 88.1 in Unit Width. 59.5 in Unit Height 41.3 in Unit Voltage- Phase - Hertz. 208 -3-60 Air Discharge' Horizontal Fan Drive Type: Belt Actual Airflow 3000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy 31.44 BTU /lb Evaporator Leaving Air DB: 58.7 F Evaporator Leaving Air WB: 57.6 F Evaporator Leaving Air Enthalpy: 24.76 BTU /lb Gross Cooling Capacity 90.10 MBH Gross Sensible Capacity: 68.90 MBH Compressor Power Input* 6.40 kW Coil Bypass Factor: 0.092 Heating Performance Heating Airflow. 3000 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 115.6 F Gas Input Capacity: 120.0 / 180.0 MBH Gas Heating Capacity. 147.60 MBH Temperature Rise* 45.6 F NOTE: Second Stage Supply Fan External Static Pressure: 1.00 in wg Options / Accessories Static Pressure Economizer: 0.15 in wg Total External Static: 1.15 in wg Fan RPM: 898 Fan Power: 2.43 BHP NOTE: Medium Static Fan Option Electrical Data Minimum Voltage: 187 Maximum Voltage* 253 Compressor #1 RLA* 13.6 Compressor #1 LRA. 83 Compressor #2 RLA 13.6 Compressor #2 LRA. 83 Outdoor Fan Motor Qty 2 Outdoor Fan FLA (ea): 1.5 Indoor Fan Motor Type: MED Indoor Fan Motor FLA 7.5 Combustion Fan Motor FLA (ea): 0.48 Packaged Rooftop Builder 1.19q Page 4 of 5 Project: - Untitled7 Prepared By: Performance Summary For Untitled1 02/02/2010 09:55AM Power Supply MCA: 41.1 Power Supply MOCP (Fuse or HACR): 50 Min. Unit Disconnect FLA. 43 Min. Unit Disconnect LRA. 230 Electrical Convenience Outlet None Acoustics Sound Power Levels, db re 10E -12 Watts Discharge Inlet Outdoor 63 Hz 100.5 97.8 90.1 125 Hz 95.1 85.5 82.6 250 Hz 80.4 77.7 81.0 500 Hz 72.1 65.5 79.4 1000 Hz 70.7 63.0 77.0 2000 Hz 70.3 60.5 73.0 4000 Hz 73.3 61.8 70.4 8000 Hz 76.5 64.2 66.7 A- Weighted 83.3 76.0 82.0 2.0 1.8 1.6 1.4 Cif c 1.2 00.8 0.6 0.4 0.2 0.0 Fan Curve MEI 11111111111111.11111 800 RPM IRE_ ►41,. 5.00 8\ 700 RPM -- 111al __'. KINIMMIEL 2.00MN EVIL25070.7111 -` 500 RPM 400 RPM 00 I I I I I ! I I I i l l I I I I I I I I 1 I I I I I I I I 04 08 12 1.6 20 24 2.8 32 36 40 44 Airflow (CFM - thousands) RPM = 898 BHP = 2.43 Maximum RPM = 1084 Maximum HP = 4.70 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point Packaged Rooftop Builder 1.19q Page 5 of 5 VIEWED F COMPLI P OVE PR 1 5 201 �• yy.� +� 77�� //�� ..yyamy yy ' ^;::� •. .. :�:W.iwiF" : y� Y is Iyi_• J :<•: %• }: : ' :F .. X J 5-6 �2 ,`5• a ° 6 i 2-0 3.( �.2.25h ..�.°•:;Y ¢ � 3 9% ;644.:? 0-3% tlf unit is i*1Sw1ed ip an:.dlcome:or of er;Sq cleera ices "for aar flo st►oxvn are to bo.: i #t irornwa* However' #t:fxontof:i a a ,.cbesi snce: or ear £ow pus be aY leas Physical data UNIT SODA OPER WT (Ib) REFRIGERANT Oper Chg (Ib) COMPRESSOR Cylinders Rpm Capacity Stages 006 008 009 700 22 90 06R 4 3500 1 805 22 13 2 06D 4 1750 860 22 13 2 OUTDOOR AIR FANS No. —Diem (in.) Nom Cfm Motor Hp...Rpm No. 1 No. 2 CONDENSER COIL Rows... Fi ns /i n. Face Area (sq ft) 1 24 4100 1/,.. 825 Propeller; Direct Drive 1 .26 5400 14 825 06D 6 1750 1 1 26 5400 % 825 INDOOR AIR FANS No....O1am (in.) Nom Cfm Motor Hp...Rpm Aluminum Plate Fins 2 15 3. 15 I 975 125 1 ..2% 2000 3/4 3450 Centrifugal; Belt Drive EVAPORATOR COIL Rows...Fins /in. Face Area (sq ft) RETURN AIR FILTERS No. ...Size (1 -in.) OUTDOOR AIR SCREENS Size (in.) 2 10% 3000 % 3450 3 15 125 2 10% 3400 1. .3450 Aluminum Plate Fins 3 15 3 15 I 3 15 432 71 71 Field Supplied Factory Supplied; Cleanable 2 .20x25 2 20x25 I 2 20x25 Factory Supplied Cleanable, Wire Mesh Type located in rooftop adapter 2 . 16x20x1 Selection procedure (wish example) I Determine cooling and heating requirements at design conditions. Given Required Cooling Capacity (TC) . . . Sensible Heat Capacity (SHC) ..... . Condenser Entering Air Temperature . Indoor Air Temperature . 80 Evaporator Air Quantity External Static Pressure Electrical Characteristics (V- Ph -Hz) .. 59,000 Btuh ...40,000 Btuh . ...95F F edb, 67 F ewb . ..2,000 cfm 06 in wg 460 -3 -60 II Select unit based on required cooling capacity. Enter Cooling Capacities table at condenser entering air temperature of 95 F. Read that at 67 F ewb and 2,000 cfm evaporator air, unit 50DA006 will provide a total capacity of 61,000 Btuh and a sensible heat capacity of 43,000 Btuh. 7 Sensible heat capacity values are based on 80 F edb For temperature other than 80 F edb, make sensible heat correction using correction factors in notes under Cooling Capacities table. III Determine fan speed and power requirements at design conditions. Enter Fan Performance table at 2,000 cfm and 0 6 in wg. Read that fan speed is 890 rpm and the power required is 0.85 bhp The standard motor and drive is adequate. If values selected are shown in italics, select a field - supplied motor or drive from Indoor Fan Motor Data table or Indoor Fan Drive Data table. IV Select unit that has required electrical characteristics. The Electrical Data table lists a 50DA006 with electrical characteristics of 460 -3-60. Performance data COOLING CAPACITIES" UNIT SODA Refrig ARI Cap. EVAP AIR TEMPERATURE AIR ENTERING CONDENSER (F) am Bf Ewb (F) 85 95 100 105 115 TC SHC t Kw TC SHC t Kw TC SHC t Kw TC SHC t Kw TC SHC t Kw 006 - 22 60 1500 16 72 67 62 68 62 56 33 40 47 7.5 7.0 6.7 64 58 52 31 39 45 8.0 7 5 7.1 62 56 50 31 38 44 8 2 7.8 7.3 59 54 49 30 37 44 8 5 8.0 7.6 55 50 45 28 36 42 9 0 8 4 8.0 2000 22 72 67 62 71 65 59 36 45 54 7 8 7 4 6.9 67 61 55 34 43 52 8.2 7 8 7.3 64 59 53 33 42 51 8.5 8 0 7 5 62 56 51 33 41 50 8 7 8 2 7 8 57 52 47 31 40 47 9 2 8 6 8.2 2500 72 67 62 74 67 61 39 49 59 7.9 7 5 7.0 69 63 57 37 47 57 8.3 7.9 7 4 66 60 55 36 46 55 8 7 8 1 7.7 64 58 53 35 45 53 8.9 8 4 7 9 59 53 48 33 44 48 9 3 8.7 8.2 008 - 22 1 91 2500 16 72 67 62 102 95 87 51 64 75 7 8 7.5 7.1 98 90 83 50 62 74 8 3 8 0 7.7 95 87 80 48 60 72 8 8 8.5 8.1 92 84 77 47 59 71 9.4 8 9 8 5 86 80 73 45 57 69 10.1 9 6 9.1 3000 72 67 62 105 97 90 54 68 82 7.9 7 5 7.2 101 93 85 52 66 80 8 5 8.1 7 9 97 90 82 51 65 79 9 0 8.6 8.3 94 86 79 49 64 77 9 5 9.1 8 7 89 82 75 48 62 75 10.1 9.7 9.3 3400 72 67 62 106 98 91, 56 71 86 7.9 7 6 7.3 102 94 86 54 70 84 8 4 8.2 7.9 98 91 84 53 68 83 9 0 8.7 8.3 95 88 80 51 67 80 9 5 9 2 8.8 90 83 76 50 65 76 10 2 9.8 9.4 009 - 22 103 3000 20 72 67 62 119 110 101 59 73 87 11.0 10.3 9.7 114 105 97 57 72 85 11 7 10.9 10.4 110 102 94 55 70 84 12 1 11 3 10.8 107 99 , 92 54 69 83 12.5 11 7 11.1 101 94 87 52 66 80 13 4 12.5 11.9 3400 22 72 67 62 121 112 103 60 76 92 11 1 10 5 9.8 115 107 98 59 74 90 11.8 11.2 10.5 112 104 95 57 73 89 12.3 11.6 10.9 12.4 11 7 11 0 109 101 93 56 72 88 12 7 11 9 11.3 102 95 88 54 69 85 13.6 12 6 11.9 3800 25 72 67 62 122 113 104 62 79 95. 11 2 10 6 9 9 117 108 100 61 77 94 12.0 11 3 10 6 113 105 97 59 76 92 110 102 95 58 75 91 12 8 12.0 11.4 103 96 89 56 72 89 13 7 12 7 12 1 Bf - Bypass Factor Kw - Compressor Motor Power Input SHC - Sensible Heat Capacity (1000 Btuh) TC - Total Capacity (1000 Btuh) *Ratings shown, with the exception of ARI Ratings, are gross capacities which do not includes deduction for fan motor heat. tSHC is based on 80 F db temperature of air entering evaporator coil Below 80 F db, subtract. (corr factor x cfm) from SHC Above 80 F db, add (Corr factor x cfm) to SHC. NOTE: Direct interpolation is permissible Do not extrapolate Low outdoor temperature operation Standard units are capable of operating at down to 40 F (50DA006), 60 F (50DA008,009) Units will operate at temperatures down to -20 F with 32 Series Motormaster® head pressure con- trol if minor modifications to unit are made For winter start (freeze -up pro- tection), evaporator defrost thermostat SHC CORRECTION FACTORS IENT AIR DRY -BULB TEMP (F) BF 79 78 77 76 75 81 ; 82 83 84 85 Interpolation is permissible Temperature under 75 or over 85 use formula. Correction Factor = i 08 x (1 - BF) x (db -801 (Carrier Part No 5013E3900001) must be installed Unit low- pressure switch must be relocated to liquid line fitting and reset to 5 psig cutout pressure Wind baffles field fabricated in accordance with Motor master instructions are also required 8 ARI Standard Ratings (1000 Btuh) - In accordance with latest Standard 210. Correction Factor .10 97 1 95 2.92 1 3 89 i 4 86 .20 86 1.73 2.59 1 3.46) 4 32 .30 .76 1 . 5 1 2 27 1 3 03 3 78 Interpolation is permissible Temperature under 75 or over 85 use formula. Correction Factor = i 08 x (1 - BF) x (db -801 (Carrier Part No 5013E3900001) must be installed Unit low- pressure switch must be relocated to liquid line fitting and reset to 5 psig cutout pressure Wind baffles field fabricated in accordance with Motor master instructions are also required 8 ARI Standard Ratings (1000 Btuh) - In accordance with latest Standard 210. Electrical data ELECTRICAL DATA UNIT V-PH-HZ VOLTAGE RANGE Min Max COMPR FLA LRA OFM FLA IFM FLA MIN WIRE AMPS MAX FUSE AMPS SODA006 207 187 207 414 518 180 207 414 518 \8O 207 414 518 254 229 254 508 632 229 264 528 660 229 264 528 660 379 25.0 21.6 10 8 9.7 30.0 26.2 13.1 12.8 40.0 36.0 18.0 17.8 150 110 100 50 40 132 124 62 50 164 153 77 62 3l 2.1 2.1 2.1 2.1 3.2 3,2 1.6 3.2 3 2 3.2 1.6 32 3.8 3W 3.8 3.8 3.8 5.0 5.0 1.3 5.0 6.3 6.3 >4 6.3 579 70 42.9 45 375 45 18.8 20 50.5 44.6 20 3 64.2 57.9 60 50 30 70 70 35 Conpr - oomnmss,, FLA - Full Load Amps IFM - Indoor Fan Motor LRA - Locked Roto Amps OFM - Outdoor Fan Motor NOTES: 1. All fan motors are single-phase motors except indoo fan motors on*wo-yultnooA' 008 and 009 These motors are 3-phase motors 2. Minimum wire amps are per NEC. 3. Maximum fuse amps shown are for dual-element type. ELECTRIC RESISTANCE HEATERS BASE UNIT SODA V/PH ELEMENT TOTAL/ HEATER 006 230/1 208/3 230/3 460/3 008 and 009 208/3 230/3 460/3 Kw Amps 6.0 I 26.0 49 13.7 6V / 15.1 6.0 7a 9.8 273 12V 30u 12V 15.0 No./Htr Kw Amps HEATERS ALLOWED PER BASE UNIT 6.0 4.9 6.0 6.0 26.0 137 151 7a 3 9.8 12.0 12.0 273 300 13.0 31, POWER SOURCE REOD/ HEATER 1-30 crnv 1-20 cmp 1-20 ornp 1-1V *=n 1'3Vcrrp 1'3nomp 1-15 ornp Power supply and wiring Units are completely factory wired, and require only one field power supply connection A separate power supply is required when accessory resistance heaters are used. When the Modulating Outdoor Air Control accessory is used, a separate 230-1-60 line is required for the giumpnr motor. Field-supplied, fused dis- connect switches are required for base unit and resistance heaters. If a single disconnect is used for more than one houta,, individual heaters must be fused. Base unit operating sequence Cooling - Power on and thermostat assembly set at "Cool," "Auto.," and desired temperature. The control relay is energized when the thermostat calls for cooling This then energizes the indoor fan, outdoor fans, Time Guard® circuit timer and holding relay. After 15 myconds, the compressor will start If the compressor should shut down for any mmmon, the timer prevents its restarting for 5 minutes 1 o If unit operation is interrupted by the Iow-pressure switch, the unit shuts down until the low-pressure switch closes and the timer motor completes its cycle If either the high-pressure switch or the compressor overloads npnn, the indoor and outdoor fans continue to operote but the compressor stops The compressor remains off until high-pressure switch or overload closes Then the compressor restarts when the timer has recycled Heating - When stage 1 of heating thermostat closes, the indoor fan and first-stage heaters energize. If additional heat is required, stage 2 of the heating thermostat will energize the remainder of the heaters Air circulation - When unit powe bon but unit controls are set at "Off" and "Fan," the indoor air fan operates con- tinuoudy When controls are set at "Cool," "Heat" and "Fan," cooling or heating is provided automatically as re- quired whi|o indoor fan operates continuously. Economizer operating sequence Cooling season - When the thermostat is set at "Cool" and ^Auto^ damper goes to "Vent" position when stage 1 of cooling thermostat closes. When stage 1 is satisfied, the damper closes. Damper stays in the "Vent" position if fan switch is at "Fan." Base unit operates as described in Base Unit Oporating Sequence Intermediate season - Same as for cool- ing season except that as stage 1 of thermostat closes and the indoor fan motor starts, the compressor and outdoor fan motor remains off if outside air temperature is below outdoor air ther- mostat setting. Heating season - When stage 1 of heating thermostat doses and mixed air tempera- tum is above mixed air thermostat :ottin0. damper modulates between and "Close" to bring mixed air temperature up to mixed air thermostat setting. Heaters operate as described in operation for base unit. SERVICE REPAIR WORKSHEET I DATE: 16- Mar -10 JOB #: USPO Tukwila JOB NAME : CONTACT : Andy Bracket ADDRESS: PHONE: FAX : SCOPE OF WORK TO BE DONE: Replace RTU SPECIAL INSTRUCTIONS: NAME: BILLING : ADDRESS: PHONE: FAX: COSTS LABOR : $3,164 MATERIAL : $9,585 PURCHASED BY FIELD I OFFICE QTY 1 Carrier Quote 1 Mis Sheet Metal 1 Mis Electrical 1 Eq Disposal 1 Mis gas materials DESCRIPTION / ITEM I Service call 12 Foreman truck costs for sheetmetal and piping 4 PE expenses 1 CONSUMABLES UNIT COST $6,041.00 $500.00 $250.00 $100.00 $750.00 $0.00 $750.00 $0.00 $0.00 $0.00 $9.95 $75.00 $25.00 TOTAL COST $6,041.00 $500.00 $250.00 $100.00 $750.00 $0.00 $750.00 $0.00 $0.00 $0.00 $119.40 $300.00 $25.00 TASK SUMMARY OF MATERIAL COSTS: $8,835.40 SUMMARY OF SUPPLEMENTAL MATERIAL COST: $0.00 HOURS STD COST SERVICE (JM) $96 $1,920.00 SERVICE (4th year) $96 $0.00 FIELD SHEET METAL $74 $888.00 TRUCKING $74 $0.00 FIELD PIPING $82 $0.00 DDC CONTROLS $110 $0.00 SHOP SHEET METAL $89 $356.00 SHOP WELDING $89 $0.00 AIR BALANCE $96 $0.00 ENGINEERING $80 $0.00 SUMMARY OF HOURLY COST $3,164.00 (SUB - CONTRACTS, PERMITS, ETC.) COST SERVICE (JM) 20 SERVICE (4th year) 0 FIELD SHEET METAL 12 TRUCKING 0 FIELD PIPING 0 DDC CONTROLS 0 SHOP SHEET METAL 4 SHOP WELDING 0 AIR BALANCE 0 ENGINEERING 0 OTHER COSTS Crane service SELL $750 $0 $0 $0 SUMMARY OF SUBS COST $750 COSTS MARKUP % SUBTOTAL: SUGGESTED SELL PRICE $17,849.16 ACTUAL SELL PRICE $17,849.16 Project Manager $12,749 40% 40% OT COST $117 $117 $0.00 $88 #4,4/4/414/4/:# $75 $0.00 $104 $0.00 $132 $0.00 $97 $386.32 $97 $0.00 $117 $0.00 $100 $0.00 $3,778.84 $12,749 SERVICE RESERVE: $0 TOTAL COST: $12,749 T Service Repair Worksheet new RTU 2.1- 10.xds APPROVED BY DATE 05 -02 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director TIM MALCOLM 835 N CENTRAL AVE #132 KENT WA 98032 RE: Permit No. M10 -046 225 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 06/24/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 06/24/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician File: Permit File No. M10 -046 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Page 1 of 1 Jennifer Marshall - Re: Permit M10 -046 USPO Tukwila extension request From: Bob Benedicto To: Tim Malcolm Date: 12/22/2010 2:43 PM Subject: Re: Permit M10 -046 USPO Tukwila extension request CC: Bill Rambo; Jennifer Marshall Tim, This E -mail will serve as confirmation of an extension to mechanical permit M10 -046. The extension is for 180 days. At the end of this period you will need to have scheduled a final inspection to address the last correction notice, or your permit will expire by ordinance limitation. Bob Benedicto, Building Official City of Tukwila 206/431 -3675 bbenedicto @ci.tukwila.wa.us »> 'Tim Malcolm" <tmalcolm @accoes.com> 12/22/2010 12:49 PM »> Hi Bob: Thanks for taking my call. Here is a copy of the request for an extension we spoke about. It was delivered to the Building dept. on 11 -30 -2010. Please let me know if there is additional information needed. Thank you for your assistance. Regards, Tim Tim Malcolm Service Project Manager ACCO Engineered Systems Inc. Office (253) 854 -8444 Fax (253) 854-8220 Cell (253) 261 -7184 file: / /C:\temp\XPGrp Wise \4D 120E96tuk- mai16300 -po 10016B6D3618C9A1 \GW} 00001.... 12/27/2010 11 -01 -2010 epartment of Community evelopment TIM MALCOLM 835 N CENTRAL AVE #132 KENT WA 98032 RE: Permit No. M10 -046 225 ANDOVER PK W TUKW Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorize by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work d authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/26/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 12/26/2010, your permit w' become null and void and any further work on the project will require a new permit and associated fees. 111 Thank you for your cooperation in this matter. Sincerely, fer Marshall t Technician File: Permit File No. M10 -046 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 ' g Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 • • PE T PLAN REVIEW /ROUTING SLIP Y ACTIVITY NUMBER: M10 -046 DATE: 04 -06 -10 PROJECT NAME: USPS SITE ADDRESS: 225 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: uildin D�sion Public Works n Pret6 VL 11111' Structural ❑ Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -08 -10 Not Applicable Permit CentetUse Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route N Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: • APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Not Approved (attach comments) n IA Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 05-06-10 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page o Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L81 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Acco Engineered Systems Inc UBI No. 601003669 Phone 8182446571 Status Active Address 6265 San Fernando Rd License No. ACCOESI971DU Suite /Apt. City Glendale State Ca Zip 91201 County Out Of State Business Type Corporation Parent Company License Type Construction Contractor Effective Date 3/31 /2003 Expiration Date 10/13/2011 Suspend Date Specialty 1 General Specialty 2 Unused fated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AIRCOI *221JL Air Conditioning Company Inc Construction Contractor Air Conditioning Boiler /Steam Fit /Proc Piping 4/13/1978 4/13/1981 Archived AIRCOCI131KQAir Conditioning Company Inc Construction Contractor Air Conditioning Plumbing 5/18/1987 10/2/2003 Inactive Business Owner Information Name Role Effective Date Expiration Date Avesano, John P President 03/31/2003 Kessler, Roberta R Secretary 03/31/2003 Brown, Robert A Treasurer 03/31/2003 Krassensky, Ronald Vice President 01/22/2004 Hammond, Robert T Vice President 01/22/2004 Marrs, Jeffrey R Vice President 01/22/2004 Narbonne, Peter H Vice President 01/22/2004 Richter, Charles K Vice President 01/22/2004 Westphal, Kenneth B Vice President 01/22/2004 Yates, Richard D Vice President 01/22/2004 Goodman, Milton L Vice President 01/22/2004 Smith, Steven J Vice President 01/22/2004 Vlick, Robert P Vice President 03/31/2003 Ludolph, Douglas E Vice President 11/06/2006 Boysen, Thomas C Secretary 01/22/2004 11/06/2006 Mcnamara, William B Vice President 03/31/2003 09/01/2004 https://fortress.wa.gov/lni/bbip/Print.aspx 06/18/2010