Loading...
HomeMy WebLinkAboutPermit M10-056 - ASHLEY FURNTIUREASHLEY FURNITURE 17601 SOUTHCENTER PY M10 -056 City oikTukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL, PERMIT Parcel No.: 3523049087 Address: 17601 SOUTHCENTER PY TUKW Project Name: ASHLEY FURNTIURE Permit Number: M10 -056 Issue Date: 05/17/2010 Permit Expires On: 11/13/2010 Owner: Name: LEVITZ TUKWILA LLC Address: 180 N STETSON AVE #324 -D , CHICAGO IL 80601 Contact Person: Name: JOHN PARKS Address: 5201 CAPITOL BL #201 , TUMWATER WA 98501 Email: J.PARKS @VAUGHNMECHANICAL.COM Contractor: Name: NORTHWEST REFRIGERATION Address: 5201 CAPITOL BL STE 201 , TUMWATER WA 98501 Contractor License No: NORTHRI0000J Phone: 360 485 -7436 Phone: 360 357 -9973 Expiration Date: 03/01/2012 DESCRIPTION OF WORK: MODIFY DUCT LAYOUT AND ADD NEW THERMOSTAT CONTROLS Value of Mechanical: $33,219.00 Type of Fire Protection: Permit Center Authorized Signature: Fees Collected: $595.56 International Mechanical Code Edition: 2009 Date: J -' ( 7— I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -056 Printed: 05 -17 -2010 Parcel No.: 3523049087 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17601 SOUTHCENTER PY TUKW ASHLEY FURNTIURE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10 -056 ISSUED 04/23/2010 05/17/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M10 -056 Printed: 05 -17 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -056 Printed: 05 -17 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: ordinances governing or local laws regulating doc: Cond -10/06 M10 -056 Printed: 05 -17 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. Sri ,O Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: �� 70/ 44-'7 �.GCn 7 Tenant Name: - '0.)4V /60- ✓S /A5Z/€7 fir",i7 :'c Property Owners Name: j�./e / /a�S Mailing Address: / 7 3/ FM /10/ ij �c/ Ora.," kis King Co Assessor's Tax No.: 36-Z-30 ok Suite Number: Floor: New Tenant: ❑ Yes [;:[: "No City /CY 5 State Zip CONTACT PERSON Who do we contact when your permit is ready to be issued Name: To .-t PL Po,r-k5 Day Telephone: .5L0-- �' 0C Mailing Address: SZO 7a/ o /✓r ". A Z'/ / City State Zip E -Mail Address: J /'k5 ��av�iti rre�c%,.,, c� �- u9-1-1 Fax Number: 3 ce— 7S L/- 7737 MECHANICAL CONTRACTOR INFORMATION Company Name: /acv - 4 n Lie- c,.7 , 'G ', Mailing Address: 5. -'-, z_ o- s c-6' Cr e- Contact Person: Sae., ,e_ a5 0, bay A E -Mail Address: // Contractor Registration Number: /t/QI 774 1-- 9 0 J City Day Telephone: Fax Number: Expiration Date: 3 /a_ State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: //�wi/dl � S e t Arc4,r/e.cA, , Mailing Address: 3939 (5P£ Cad y /4/1 • 6'- - " 1‘7L/c) ,[ City State Zip Contact Person: )//74 ' E -Mail Address: G�c v/ GchOvci/ ?cC /� 4C. CG✓t---) Fax Number: Day Telephone: 572 3L f C ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: 4/6/0 Zo`1y. 5/. C7 6 Contact Person: t'°// s3 �SS E -Mail Address: e� v; 'Jc e ,--t) ��? ya��c• . G'a� H: \Applications\Forms - Applications On Line\2009 Applications \1 - 20099-- Mechanical Permit Application.doc Revised: 1 -2009 bh Ahz /75,, 5 /0 ,-tr 1 t ��i' City tate Zip Day Telephone: Z5-3- 353 - 0 5Z' Fax Number: Z'73 _ 3 2..5--- C,✓ yC., Page 1 of 2 Valuation of Project (contractor's bid price): $ 33 2// Q Scope of Work (please provide detailed information): ': A � C cJC/- A 7 0,// /1e f�* rhd5t41- )11/(015 Use: Residential: New Commercial: New Replacement Replacement Fuel Type: Electric ❑ Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ED NT: Signature: Print Name: Mailing Address: T i —,Es 520 / 6 Date: 7- -c2 —/G Day Telephone: 360 — City 6/4 9T-4o/ State Zip Date Application Accepted: N174,0 Date Application Expires: io ithp Staff Initials: H:WpplicationsTorms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049087 Permit Number: M10 -056 Address: 17601 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 04/23/2010 Applicant: ASHLEY FURNTIURE Issue Date: Receipt No.: R10 -00856 Payment Amount: $476.45 Initials: WER Payment Date: 05/17/2010 01:58 PM User ID: 1655 Balance: $0.00 Payee: VAUGHN MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 25526 476.45 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 476.45 Total: $476.45 P'YM E NT RECEIVED doc: Receipt -06 Printed: 05 -17 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049087 Permit Number: M10 -056 Address: 17601 SOUTHCENTER PY TUKV/ Status: PENDING Suite No: Applied Date: 04/23/2010 Applicant: ASHLEY FURNTIURE Issue Date: Receipt No.: R10 -00692 Initials: User ID: Payee: JEM 1165 Payment Amount: $119.11 Payment Date: 04/23/2010 10:18 AM Balance: $476.45 VAUGHN MECHANICAL, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 25469 119.11 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 119.11 Total: $119.11 PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -23 -2010 INSPECTION RECORD AA 1(0 Retain a copy with permit i vt 117 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION +� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Progt . / c t)'A r"T I rn Type of In n • • /I 1 /al f-, AA i 1 (iu) ( f__S pivigAft/a P/Datewanted: Date Called: Special Instructions: may, �, _ r , I a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION " 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • Proje t: tAl Type of Inspection: Ad ress: /1te�iJ sr�AT� Date Called: Special Instructions: Date Wanted: ( l) a m p.m. Requester: Phone No: 9 51 - -s-o -9 -,d Approved per applicable codes. ' El Corrections required prior to approval. COMMENTS: 445r) IA.'S . 1 A Date: REINSPE-CTION FEE REQUIRED: Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to. schedule reinspection.. • • -q44 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1("\ M 0-516 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project • // Type of Inspectimv Address: i 7 Date Called: Special Instructions: Date Wanted: K - / 0 ' x(10 m p.m. Requester: Phone No: EIApproved per applicable codes. El Corrections required prior to approval. / COMMENTS: r ' :v6 .J Are o✓ Y Inspe date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTIONNO. Ci INSPECTION RECORD M 0 _ds Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Z 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro g: k k I�,) ,`t is Typ of Inspection: �.��G � e�� Address: 1'� �d SCJ I Date Cal d: �/1s(J ( .lt v. Jc.Y Special Instructions: P Date Wanted: S-1‘./C) en:1" Requester: Phozne 5, _ S ?'off 0 Approved per applicable codes. Corrections required prior to approval. t COMMENTS: PUT Ai( A f f ( r J;�' At_ 1/N -- - 1 2 k ;vb. :A\"Le � ry 3) 1 41- ilL 11-3 orti--; ,e 1 Z A- ,[3P• -Ci.n & I 04 .I Inspector: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: -AA-3 oo-r-ie.edAy GEC INSPECTION RECORD ��O a� Retain a copy with permit 1"' • INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro'ect: A SIA t� FL) %A (‘T:1 r f Type of Inspectipn: (�c, ____ [., u _ a , Qc, Address: v p Date Calle As c Special Instructions: / 6 r c a.pi, Requester: Phone Nom r r l -0541' f Approved per applicable codes. Corrections required prior to approval. /7 COMMENTS: CD )-e_r\ v p S €. AA 3 $ As c , "..s p e,.(3-- di AS'd c- 6 r A- (k .AJi o f /UST- i-NJ 1 A 4 U A r r` kn, AS 6-? Q.ii t`n cie e.or c Inspec Date: r $60.00 REINSPECTION FEE R UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blv ,., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: -1=P20 INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION rf.— 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2061431 -3670 INSPECTION RECORD Retain a copy with permit cA4 %4I9 -OSJO PERMIT NO. Proj ct: A-1k LC/ ' ft. i i 4 ( ai a TypeAf Inspection: — ` A / e j Address: P-u 3 S.4 t) S. c.,) Q e.dl d+ri; Date Called: Special Instructions: /Date Wanted: / `Al rn, Requester: Phone No: 253- Sol- a8.47- ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: .- 3,4, I+V•w• ct, -ner SA -125 Aru -2 .4. 0 cel l Weir s4.f f P-u 3 S.4 t) S. c.,) Q e.dl d+ri; (Cry »4 5.13- .4 &Jrne% R,t-t -/f 0 /LTV — e S • 0 . f IY_Wei J 7 v- (g J.0 - S. f. r.l Us J/\JS4,41 ,A.ePf,,i,A( /� f`vi -.6 in � -A n(a /.�Je.,_ eG i €S7 rin,'-A cc__, 1 - / .., t A 1 Inspector: (Date: s tr.,,' 1-1$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila Wa. 98188 - - 206- 575 -4407 Project: -� Fire Alarm:' Hood & Duct: pi Type of Inspection: Pre- Fire: /Joe. Permits: f Address: Sure #: :. c_.. c . _.f Contact Berson -1 - -c i:1. Special Instructions: Phone No.: 9 ) Approved per applicable codes. Corrections required prior to approval COMMENTS: Sprinklers: Fire Alarm:' Hood & Duct: pi Monitor: r , i - (.7,,,ffi.,.. .. Pre- Fire: /Joe. Permits: f Occupancy Type: (V\ / � 1 .+ +.o...- , ! �...,; '�� sf -e,./t./ ' / f yt�, 1,)_5./4 e ,,� i - ! � � t ti / . ` ✓' i •i.,f'-. L V � v ,.,G'0,,..1.,,, ✓ �. I, r, s Yea. f l 4 1`ri t{ i -i-"' . f � i `} t� . F .. ..� ' r 7 -L. ti- '- 1 ... .....- ?.._K. (7,...-, r / {j X"�,`+jf f x, :� .,: i,,.:l. •+ (f `? t ." is (C. . ^3[ ii t:AS S 1 ti,. Z" a ✓J, t Needs Shift Inspection:' Sprinklers: Fire Alarm:' Hood & Duct: pi Monitor: r , i - (.7,,,ffi.,.. .. Pre- Fire: /Joe. Permits: f Occupancy Type: (V\ Inspector: Date: 9 rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City o€ . M f Tlnance Department. Cali to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT INSPECTION RECORD Retain a copy with permit 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: ' ,, h/ �- (.),/ e.. Type 9k Ins on: r ,04.5.. L ` , `� '1 Address: Suite *: , . / < r °" Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre- Fire: Permits: Occupancy Type: a A-b j CO ti' c. J r4: (,h. vS C� 0„ tf G. . 4- CA-C i' ■ `p r' , 5 - � .. tali )oti C x (Cif i 4. 6 . )AJ 6, -. y Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre- Fire: Permits: Occupancy Type: Inspector: Date: H . r1. .• E $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of T once Department. CaII to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form FILE COPY Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info _ Project Address i260/ �' y, ,/ Date %v , ic, it/4 / For Building Dept. Use Location Ey, SJi'y� Applicant Name: //aa5A, Rec.( l7 city Applicant Address: Applicant Phone: �` Project Description Briefly describe mechanical system type and features. IEdes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name Model No.1 Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location Ey, SJi'y� 7;:a an city �` BUBL®IM G DIMS( f 1Al M tt) .....0 5(iff I �_.._%� t P; i 10 ..�li ,- = �_: Ili Heating Equipment Schedule Equip. ID Name Model No. No.1 Capacity2 Btu /h Total CFM OSA cfm or Econo? Input p t Btuh Output Btuh y4 Efficiency4 ��iiBrand city �` BUBL®IM G DIMS( f 1Al M tt) .....0 5(iff I �_.._%� t P; i 10 ..�li ,- = �_: Ili Fan Equipment Schedule tqAi 1 L /01U Equip. ID Brand Model No.1 CFM HP/BHP Flow Controls Location of Service Name' /�- 1ii'ST.� city �` BUBL®IM G DIMS( f 1Al M tt) .....0 5(iff CITY OF TUKWILA - BUILDING DIVISION _2006 Washingtop tatR,N• nresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: • Constant vol? • Air cooled? • Packaged sys? • <20,000 Btuh? ❑ Split system? Economizer included? • If Heating Only: <70% outside air? Is <5000 5000 cfm? • Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Heating /Cooling or Cooling Only Reference Section 1421 Yes — No Reference Section 14231 otal Ca . wo economize <240,000 Btuh or 10 %? Simple System Allowed (section 1420) Use Complex ► Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist 1 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Project Address 'Date The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section (Component ,Information Required Location I on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls v1412.1 Y.1 Temperature zones Indicate locations on plans 1412.2 Deadband control Indicate 5 degree deadband minimum 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control ye, 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems Y" 1414.1 Duct sealing Indicate sealing necessary y.e "2 1414.2 Duct insulation Indicate R -value of insulation on duct 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan �.QS 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing Yel 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 2006 Washin ton State Nonresidential Eners Code Com • Iiance Form • Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms' Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a produ ct covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air fumaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All fumaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Sery ice Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: MECH -CHK Revised July 2007 1411.4 Packag equipment prow ding both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and co oling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full loa d demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close au tomatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire a larm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation, 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 14148 Vent0ation controls tor High - occupancy areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mech anical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculati on, all factors including solar and internal load shall be the same as those used for peak Toad calculations, except for the outside temperatures. Exception: Water economizers using air- cooled heat rejection equipment may use a 35 °F dry-bulb outside air to mperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. • Individual, direct ex pansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humid ification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS- 18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at stati c pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These re quirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full loa d demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close au tomatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire a larm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation, 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 14148 Vent0ation controls tor High - occupancy areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mech anical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculati on, all factors including solar and internal load shall be the same as those used for peak Toad calculations, except for the outside temperatures. Exception: Water economizers using air- cooled heat rejection equipment may use a 35 °F dry-bulb outside air to mperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. • Individual, direct ex pansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humid ification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS- 18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at stati c pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These re quirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated 1 • 2. Combustion air intakes. 2006 Washington State Nonreside 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btulh shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. ntt Ef rWACKi13/G ITAP*M cRiailices to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) A-, Zc or C. FILE CSI FY Permit No - REVIEWED FOR CODE *MP HN ;E MAME Nr:1 12 2010 City ofTu� � �a BUILDING DIVISION Clrr: .� APR 2 3 2010 PERMIT CSR • PERMS COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -056 PROJECT NAME: ASHLEY FURNITURE SITE ADDRESS: 17601 SOUTHCENTER PY DATE: 04/23/10 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 04.1)0 t►� Bulding Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 14f Incomplete DUE DATE: 04/27/10 Not Applicable Permit Center Use Only • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Building Please Route IFIK Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/25/10 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pfter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Northwest Refrigeration Inc UBI No. 601437459 Phone 3603579973 Status Active Address 5201 Capitol Blvd Ste 201 License No. N0RTHRI0000J Suite /Apt. License Type Construction Contractor City Tumwater Effective Date 9/11/2000 State Wa Expiration Date 3/1/2012 Zip 985010201 Suspend Date County Thurston Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status N0RTHR'033BM Northwest Refrigeration Construction Contractor Air Conditioning Other (Specify) 1/14/1997 8/20/2000 Archived NORTHR'13605 Northwest Refrigeration Construction Contractor Mr Conditioning Commercial/ Industrial /Refrig 9/10/19878/20/1996 Until Cancelled Archived VAUGHR'131N1 Vaughn's Refrigeration Construction Contractor Air Conditioning Commercial/ Industrial /Refrig 8/21/19878/20/1988 01/25/2007 Archived Business Owner Information Name Role Effective Date Expiration Date Murphie, Vaughn President 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 COLONIAL AM CAS & SURETY OF MD LPM4067166 09/07/2004 Until Cancelled $12,000.0009/13 /2004 4 MID CENTURY INS CO 697000872 09/07/2001 Until Cancelled 09/07/2004 $12,000.0002/27 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 9 UNITRIN PROPERTY & CAS KPP1004279 01/25/2010 01/25/2011 $1,000,000.00 01/20/2010 8 UNITRIN PROP CAS INS CAP2502071 01/25/2007 01/25/2010 $1,000,000.00 01/22/2009 7 UNITRIN PROP & CAS C4P0064062 01/25/2007 01/25/2008 $1,000,000.00 01/24/2007 6 MID-CENTURY INS CO 602043509 01/25/2000 01/25/2008 $2,000,000.00 01/16/2007 3 CNA INS CO 1029693477 03/02/1998 Until Cancelled Summons /Complaint Information Cause Complaint Judgment Status Payment Paid By 09 -2- 00919 -5 FERGUSON ENTERPRISES INC Date: 04/16/2009 Amount: $5,726.66 Date: Dismissed Date: https://fortress.wa.gov/lni/bbip/Print.aspx 05/17/2010 . i RI1- RI- .iISTI- R S--N I- D L F SYMBOL MFR MODEL SIZE OBD QUANTITY NC SA - 1 Shoemaker 901 Series 28 x 10 no 19 <30 SA - 2 Shoemaker 901 Series 12 x 4 no 3 <35 SA - 3 Shoemaker 901 Series 12 x 8 no 27 <35 SA - 4 Shoemaker 901 Series 6 x 6 no 6 <35 SA - 5 Shoemaker 901 Series 36 x 36 no 2 <35 RA - 1 Shoemaker 905 Series 30 x 30 no 1 <35 RA - 2 Shoemaker 905 Series 20 x 10 no 2 <35 RA - 3 Shoemaker 905 Series 48 x 36 no 7 <35 TG Shoemaker 901 Series 28 x 10 no 2 <30 FLEXIBLE & SPIRO DUCT DETAIL V X 18 GAGE BAND CLAMP ,_._ R S 2 I- D SYMBOL MFR MODEL VOLTAGE QUANTITY SD-1/RTU-1 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-2/RTU-2 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-3/RTU-3 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-4/RTU-4 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-5/RTU-5 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-6/RTU-6 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR Notes: SD-1 through S-6 to oe installeo in Return Duct o-F o.11 Rooftop Units r--' No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. .-.\ \H- \ DT D I- I- __,SE- R S: D SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba \OteS: INCOMMING DUCT ///r---CEILING DIFFUSER CEILING DIFFUSER DETAIL SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Klectrical rrlumbing 50MsPiping City of Tukwila EARDING DIVISION FELE Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION \CT S: GENERAL NOTES 1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1 2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM, 4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE 5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50 6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON PROJECT COMPLETION COORDINATION NOTES GENERAL CONTRACTOR 1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO PROVIDE SIZE AND LOCATION 2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED. GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE FRAMING OPENINGS. 3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED. 4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING AS REQUIRED FOR MECHANICAL WORK, 5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS. 7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING MEMBERS OF MECHANICAL EQUIPMENT. 8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA MATERIAL AS REQUIRED FOR HVAC INSTALLATION. PLUMBING CONTRACTOR 1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH AIR INTAKES, 2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE ELECTRICAL CONTRACTOR 1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT. 2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS, 3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH 4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH PIECE OF MECHANICAL EQUIPMENT. 5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS, 6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT, COMPLETION AS-BUILT RECORD DRAWINGS 1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1 TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE. 0 & M MANUALS 1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.2 TO OWNER, SYSTEM - BALANCING 1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER. 1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1 AND 1416,4,2 2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS, VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND TEST REPORT, 3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE, AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING PER WSEC 1413 4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.42,2.1 5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND FILED WITH THE OWNER, STAT S/- 1 - 1D._ NCITES SYMBOL MFR TYPE MODEL # QUANITY T HONEYWELL TOUCHSCREEN T 7581 6 NOTES _ all Thermostats to be installed in Network Room - all Thermostats and Temp.-Sensors to be installed 54a AFF .. __ S- \S R ' S'.- 11- D L SYMBOL. AREA SERVED MFR MODEL QUANTITY S Showroom HONEYWELL WR 21-23 6 NOTES - the Temp,-Sensors will be installed like shown in the Detail Page REVIEWED FOR CODE COMPLIANCE APPROVED MA 1. 2 2010 kW-- City of Tukwila BUILDING DIVISION CITY 0 APR 2 3 2010 PERMIT CENTER LA p\,\. 0 --- 0 5g - EP SPIR DUCT AS CLOSE AS P-SSIBLE IC CEILING z (17)1 LJ APPROVED (/) uJ z < Z Pq 0 LY 11 <:(4 1-1 (/) U LA C=4 d U < m 06 • cp cf 0) Nt 1_1.1 cu uI co 1 3 co C3 0 CO C> w U co -1-› ▪ ni cu -P : '4- 0 _C Lfl •ct* U CD c) 5 ‘,1 I 2, CY) c 1.0 z I- . .._, \ \ 1 1- D R I SYMBOL A AREA M MFR M MODEL T TOTAL AIRFLOW CFM O OUTSIDE AIR CFM E ECONOMIZER RTU-1 S SHOWROOM T TRANE Y YCD300B 1 10,000 3 3,300 Y YES E EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006 RTU-2 S SHOWROOM T TRANE Y YCD300B 1 10,000 3 3,300 Y YES E EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006 RTU-3 S SHOWROOM T TRANE Y YCD300B 1 10,000 3 3,300 Y YES E EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006 RTU-4 S SHOWROOM T TRANE Y YSC120A 4 4,000 1 1,300 Y YES E EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006 RTU-5 S SHOWROOM T TRANE Y YSC120A 4 4,000 1 1,300 Y YES E EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006 RTU-6 S SHOWROOM T TRANE Y YSC120A 4 4,000 1 1,300 , Y YES E EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006 RI1- RI- .iISTI- R S--N I- D L F SYMBOL MFR MODEL SIZE OBD QUANTITY NC SA - 1 Shoemaker 901 Series 28 x 10 no 19 <30 SA - 2 Shoemaker 901 Series 12 x 4 no 3 <35 SA - 3 Shoemaker 901 Series 12 x 8 no 27 <35 SA - 4 Shoemaker 901 Series 6 x 6 no 6 <35 SA - 5 Shoemaker 901 Series 36 x 36 no 2 <35 RA - 1 Shoemaker 905 Series 30 x 30 no 1 <35 RA - 2 Shoemaker 905 Series 20 x 10 no 2 <35 RA - 3 Shoemaker 905 Series 48 x 36 no 7 <35 TG Shoemaker 901 Series 28 x 10 no 2 <30 FLEXIBLE & SPIRO DUCT DETAIL V X 18 GAGE BAND CLAMP ,_._ R S 2 I- D SYMBOL MFR MODEL VOLTAGE QUANTITY SD-1/RTU-1 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-2/RTU-2 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-3/RTU-3 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-4/RTU-4 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-5/RTU-5 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-6/RTU-6 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR Notes: SD-1 through S-6 to oe installeo in Return Duct o-F o.11 Rooftop Units r--' No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. .-.\ \H- \ DT D I- I- __,SE- R S: D SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba \OteS: INCOMMING DUCT ///r---CEILING DIFFUSER CEILING DIFFUSER DETAIL SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Klectrical rrlumbing 50MsPiping City of Tukwila EARDING DIVISION FELE Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION \CT S: GENERAL NOTES 1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1 2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM, 4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE 5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50 6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON PROJECT COMPLETION COORDINATION NOTES GENERAL CONTRACTOR 1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO PROVIDE SIZE AND LOCATION 2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED. GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE FRAMING OPENINGS. 3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED. 4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING AS REQUIRED FOR MECHANICAL WORK, 5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS. 7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING MEMBERS OF MECHANICAL EQUIPMENT. 8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA MATERIAL AS REQUIRED FOR HVAC INSTALLATION. PLUMBING CONTRACTOR 1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH AIR INTAKES, 2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE ELECTRICAL CONTRACTOR 1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT. 2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS, 3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH 4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH PIECE OF MECHANICAL EQUIPMENT. 5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS, 6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT, COMPLETION AS-BUILT RECORD DRAWINGS 1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1 TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE. 0 & M MANUALS 1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.2 TO OWNER, SYSTEM - BALANCING 1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER. 1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1 AND 1416,4,2 2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS, VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND TEST REPORT, 3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE, AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING PER WSEC 1413 4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.42,2.1 5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND FILED WITH THE OWNER, STAT S/- 1 - 1D._ NCITES SYMBOL MFR TYPE MODEL # QUANITY T HONEYWELL TOUCHSCREEN T 7581 6 NOTES _ all Thermostats to be installed in Network Room - all Thermostats and Temp.-Sensors to be installed 54a AFF .. __ S- \S R ' S'.- 11- D L SYMBOL. AREA SERVED MFR MODEL QUANTITY S Showroom HONEYWELL WR 21-23 6 NOTES - the Temp,-Sensors will be installed like shown in the Detail Page REVIEWED FOR CODE COMPLIANCE APPROVED MA 1. 2 2010 kW-- City of Tukwila BUILDING DIVISION CITY 0 APR 2 3 2010 PERMIT CENTER LA p\,\. 0 --- 0 5g - EP SPIR DUCT AS CLOSE AS P-SSIBLE IC CEILING z (17)1 LJ APPROVED (/) uJ z < Z Pq 0 LY 11 <:(4 1-1 (/) U LA C=4 d U < m 06 • cp cf 0) Nt 1_1.1 cu uI co 1 3 co C3 0 CO C> w U co -1-› ▪ ni cu -P : '4- 0 _C Lfl •ct* U CD c) 5 ‘,1 I 2, CY) c 1.0 z FLEXIBLE & SPIRO DUCT DETAIL V X 18 GAGE BAND CLAMP ,_._ R S 2 I- D SYMBOL MFR MODEL VOLTAGE QUANTITY SD-1/RTU-1 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-2/RTU-2 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-3/RTU-3 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-4/RTU-4 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-5/RTU-5 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR SD-6/RTU-6 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR Notes: SD-1 through S-6 to oe installeo in Return Duct o-F o.11 Rooftop Units r--' No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. .-.\ \H- \ DT D I- I- __,SE- R S: D SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba \OteS: INCOMMING DUCT ///r---CEILING DIFFUSER CEILING DIFFUSER DETAIL SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Klectrical rrlumbing 50MsPiping City of Tukwila EARDING DIVISION FELE Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION \CT S: GENERAL NOTES 1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1 2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM, 4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE 5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50 6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON PROJECT COMPLETION COORDINATION NOTES GENERAL CONTRACTOR 1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO PROVIDE SIZE AND LOCATION 2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED. GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE FRAMING OPENINGS. 3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED. 4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING AS REQUIRED FOR MECHANICAL WORK, 5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS. 7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING MEMBERS OF MECHANICAL EQUIPMENT. 8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA MATERIAL AS REQUIRED FOR HVAC INSTALLATION. PLUMBING CONTRACTOR 1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH AIR INTAKES, 2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE ELECTRICAL CONTRACTOR 1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT. 2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS, 3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH 4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH PIECE OF MECHANICAL EQUIPMENT. 5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS, 6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT, COMPLETION AS-BUILT RECORD DRAWINGS 1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1 TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE. 0 & M MANUALS 1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.2 TO OWNER, SYSTEM - BALANCING 1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER. 1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1 AND 1416,4,2 2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS, VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND TEST REPORT, 3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE, AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING PER WSEC 1413 4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.42,2.1 5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND FILED WITH THE OWNER, STAT S/- 1 - 1D._ NCITES SYMBOL MFR TYPE MODEL # QUANITY T HONEYWELL TOUCHSCREEN T 7581 6 NOTES _ all Thermostats to be installed in Network Room - all Thermostats and Temp.-Sensors to be installed 54a AFF .. __ S- \S R ' S'.- 11- D L SYMBOL. AREA SERVED MFR MODEL QUANTITY S Showroom HONEYWELL WR 21-23 6 NOTES - the Temp,-Sensors will be installed like shown in the Detail Page REVIEWED FOR CODE COMPLIANCE APPROVED MA 1. 2 2010 kW-- City of Tukwila BUILDING DIVISION CITY 0 APR 2 3 2010 PERMIT CENTER LA p\,\. 0 --- 0 5g - EP SPIR DUCT AS CLOSE AS P-SSIBLE IC CEILING z (17)1 LJ APPROVED (/) uJ z < Z Pq 0 LY 11 <:(4 1-1 (/) U LA C=4 d U < m 06 • cp cf 0) Nt 1_1.1 cu uI co 1 3 co C3 0 CO C> w U co -1-› ▪ ni cu -P : '4- 0 _C Lfl •ct* U CD c) 5 ‘,1 I 2, CY) c 1.0 z r--' No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. .-.\ \H- \ DT D I- I- __,SE- R S: D SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba \OteS: INCOMMING DUCT ///r---CEILING DIFFUSER CEILING DIFFUSER DETAIL SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Klectrical rrlumbing 50MsPiping City of Tukwila EARDING DIVISION FELE Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION \CT S: GENERAL NOTES 1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1 2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM, 4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE 5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50 6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON PROJECT COMPLETION COORDINATION NOTES GENERAL CONTRACTOR 1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO PROVIDE SIZE AND LOCATION 2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED. GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE FRAMING OPENINGS. 3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED. 4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING AS REQUIRED FOR MECHANICAL WORK, 5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS. 7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING MEMBERS OF MECHANICAL EQUIPMENT. 8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA MATERIAL AS REQUIRED FOR HVAC INSTALLATION. PLUMBING CONTRACTOR 1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH AIR INTAKES, 2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE ELECTRICAL CONTRACTOR 1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT. 2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS, 3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH 4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH PIECE OF MECHANICAL EQUIPMENT. 5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS, 6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT, COMPLETION AS-BUILT RECORD DRAWINGS 1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1 TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE. 0 & M MANUALS 1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.2 TO OWNER, SYSTEM - BALANCING 1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER. 1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1 AND 1416,4,2 2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS, VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND TEST REPORT, 3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE, AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING PER WSEC 1413 4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.42,2.1 5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND FILED WITH THE OWNER, STAT S/- 1 - 1D._ NCITES SYMBOL MFR TYPE MODEL # QUANITY T HONEYWELL TOUCHSCREEN T 7581 6 NOTES _ all Thermostats to be installed in Network Room - all Thermostats and Temp.-Sensors to be installed 54a AFF .. __ S- \S R ' S'.- 11- D L SYMBOL. AREA SERVED MFR MODEL QUANTITY S Showroom HONEYWELL WR 21-23 6 NOTES - the Temp,-Sensors will be installed like shown in the Detail Page REVIEWED FOR CODE COMPLIANCE APPROVED MA 1. 2 2010 kW-- City of Tukwila BUILDING DIVISION CITY 0 APR 2 3 2010 PERMIT CENTER LA p\,\. 0 --- 0 5g - EP SPIR DUCT AS CLOSE AS P-SSIBLE IC CEILING z (17)1 LJ APPROVED (/) uJ z < Z Pq 0 LY 11 <:(4 1-1 (/) U LA C=4 d U < m 06 • cp cf 0) Nt 1_1.1 cu uI co 1 3 co C3 0 CO C> w U co -1-› ▪ ni cu -P : '4- 0 _C Lfl •ct* U CD c) 5 ‘,1 I 2, CY) c 1.0 z INCOMMING DUCT ///r---CEILING DIFFUSER CEILING DIFFUSER DETAIL SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Klectrical rrlumbing 50MsPiping City of Tukwila EARDING DIVISION FELE Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION \CT S: GENERAL NOTES 1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1 2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM, 4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE 5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50 6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON PROJECT COMPLETION COORDINATION NOTES GENERAL CONTRACTOR 1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO PROVIDE SIZE AND LOCATION 2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED. GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE FRAMING OPENINGS. 3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED. 4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING AS REQUIRED FOR MECHANICAL WORK, 5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT, 6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS. 7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING MEMBERS OF MECHANICAL EQUIPMENT. 8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA MATERIAL AS REQUIRED FOR HVAC INSTALLATION. PLUMBING CONTRACTOR 1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH AIR INTAKES, 2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE ELECTRICAL CONTRACTOR 1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT. 2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS, 3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH 4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH PIECE OF MECHANICAL EQUIPMENT. 5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS, 6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT, COMPLETION AS-BUILT RECORD DRAWINGS 1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1 TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE. 0 & M MANUALS 1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.2 TO OWNER, SYSTEM - BALANCING 1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER. 1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1 AND 1416,4,2 2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS, VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND TEST REPORT, 3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE, AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING PER WSEC 1413 4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.42,2.1 5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND FILED WITH THE OWNER, STAT S/- 1 - 1D._ NCITES SYMBOL MFR TYPE MODEL # QUANITY T HONEYWELL TOUCHSCREEN T 7581 6 NOTES _ all Thermostats to be installed in Network Room - all Thermostats and Temp.-Sensors to be installed 54a AFF .. __ S- \S R ' S'.- 11- D L SYMBOL. AREA SERVED MFR MODEL QUANTITY S Showroom HONEYWELL WR 21-23 6 NOTES - the Temp,-Sensors will be installed like shown in the Detail Page REVIEWED FOR CODE COMPLIANCE APPROVED MA 1. 2 2010 kW-- City of Tukwila BUILDING DIVISION CITY 0 APR 2 3 2010 PERMIT CENTER LA p\,\. 0 --- 0 5g - EP SPIR DUCT AS CLOSE AS P-SSIBLE IC CEILING z (17)1 LJ APPROVED (/) uJ z < Z Pq 0 LY 11 <:(4 1-1 (/) U LA C=4 d U < m 06 • cp cf 0) Nt 1_1.1 cu uI co 1 3 co C3 0 CO C> w U co -1-› ▪ ni cu -P : '4- 0 _C Lfl •ct* U CD c) 5 ‘,1 I 2, CY) c 1.0 z S- \S R ' S'.- 11- D L SYMBOL. AREA SERVED MFR MODEL QUANTITY S Showroom HONEYWELL WR 21-23 6 NOTES - the Temp,-Sensors will be installed like shown in the Detail Page REVIEWED FOR CODE COMPLIANCE APPROVED MA 1. 2 2010 kW-- City of Tukwila BUILDING DIVISION CITY 0 APR 2 3 2010 PERMIT CENTER LA p\,\. 0 --- 0 5g - EP SPIR DUCT AS CLOSE AS P-SSIBLE IC CEILING z (17)1 LJ APPROVED (/) uJ z < Z Pq 0 LY 11 <:(4 1-1 (/) U LA C=4 d U < m 06 • cp cf 0) Nt 1_1.1 cu uI co 1 3 co C3 0 CO C> w U co -1-› ▪ ni cu -P : '4- 0 _C Lfl •ct* U CD c) 5 ‘,1 I 2, CY) c 1.0 z REVIEWED FOR CODE COMPLIANCE APPROVED MA 1. 2 2010 kW-- City of Tukwila BUILDING DIVISION CITY 0 APR 2 3 2010 PERMIT CENTER LA p\,\. 0 --- 0 5g - EP SPIR DUCT AS CLOSE AS P-SSIBLE IC CEILING z (17)1 LJ APPROVED (/) uJ z < Z Pq 0 LY 11 <:(4 1-1 (/) U LA C=4 d U < m 06 • cp cf 0) Nt 1_1.1 cu uI co 1 3 co C3 0 CO C> w U co -1-› ▪ ni cu -P : '4- 0 _C Lfl •ct* U CD c) 5 ‘,1 I 2, CY) c 1.0 z EXI T. ELE I q (-0 1 •s.,11 SA-4 75CFM PC 4 SA-3 400CFM 10" 12" RT1,1 RTU4 FT111.4 Irrua ITTL. SA-3 300CFM • 10" • I)J 1,1 16" • 6" 1 24^ SD-4 IL • 6" 1 SA4 75CFM RA-1 F t• A11=11 10" SA-3 400CFM 1 SA-3 500CFM 10^ 10" RTU-4 • U-4 SA-3 400CFM ENTRY 100 SA-3 500CFM 1 if I o (I 1 q I 4 I a 1 SA-4 100CFM SA-3 500CFM 36" SD1 10" RA-3 14" SA-3 SA-3 1 500CFM 500CFM 18" rti RTU-tr • 24"x40" SA-1 1200CFM SA-3 500CFM 18" SA-1 '600CFM ' 110 , :11'1 ,1.••• •',1' :1j• ; rT SA-4 1 12" 50CFM .14•4 _Q" 16"; Fri rr-.1 12" UU U SA-3 ,SA-3 401C 1 NI 1111 16" I D_ 121, , SA-4 50CFM L--- SA-4 4 ■s 1^21 150CFM 1071 j. 47._ SA-3 __I I LE 1 Li 14" SA-3 500CFM 10^ ^-1 SA-3 500CFM SA-1 1200CFM ; SA-1 1200CFM ,•77 1 ft! • I 010, # • #4 "4 SA-3 500CFM 10" „SA-1 1200CFM 7 18" 1 4,12/2/4/4,?2/4"&i&23 r,":04',"/.&4fiZ,•2,2.&:2;f&71.Z4V,,,,,..I21.11.! ! 1-- , '----7-• - ....,-V--,V, ■ 1 , • 1 . , • , • 1 1112,V12,z.1/21•,•4,•••,,w/404,,,,,,Weezzzzw"la•Z•;•'42Zztily.:2.,,,"o/YA11,/,:f-4/../.z.,=,/,,,,,,V•YA,/,,,.Y",,,/,/ -1,749/4,24.62Zare.:2 • 1 • Concentric Discharge and Return RTU-5 SA-3 500CFM SALES 1 26 SA-3 500CFM 10" RTU-2 • PIA-3 24" SD-2 SA-1 1200CFM RA-3 1 24" RTUr2 10" SA-1 1200CFM 18" ! L 7 SA-3 500CFM 1 SA-3 500CFM SA-3 500CFM RU-6 20" 4: 18^ 14" SD-6 RA-3 24" L is."11 18" SA-3 RA-3 600CFM 600CFM 1 12" T- 11:" ;--, SA-3 SA-1 :1200CFM 1 ELECTRONICS 1 • RA-3 RTU-6 SD-3 SA-3 600CFM CLEARANCE 1 1 7 30" I I RA-3 RTU-3 SA-1 1200CFM SA-1 1200CFM SA-1 1200CFM TG-1 \ 7G-11 36" I SA-1 • 1200CFM 34" SA-1 FL 1200CFM 1200CFM SA-1 FL 1200CFM Ji , '•••••-, 14" 11 SA-2•1 150CF REVIEWED FOR CODE COMPLIANCE APPROVED IV( 1 2 2010 • • • City of Tukwila BUILDING DIVIRIM crry Fi i-dri 2010 PERMIT C z 0 c 411 LLI to v- ct 4 00 APPROVED SHEET NO. MI00-.054)