HomeMy WebLinkAboutPermit M10-056 - ASHLEY FURNTIUREASHLEY FURNITURE
17601 SOUTHCENTER PY
M10 -056
City oikTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
MECHANICAL, PERMIT
Parcel No.: 3523049087
Address: 17601 SOUTHCENTER PY TUKW
Project Name: ASHLEY FURNTIURE
Permit Number: M10 -056
Issue Date: 05/17/2010
Permit Expires On: 11/13/2010
Owner:
Name: LEVITZ TUKWILA LLC
Address: 180 N STETSON AVE #324 -D , CHICAGO IL 80601
Contact Person:
Name: JOHN PARKS
Address: 5201 CAPITOL BL #201 , TUMWATER WA 98501
Email: J.PARKS @VAUGHNMECHANICAL.COM
Contractor:
Name: NORTHWEST REFRIGERATION
Address: 5201 CAPITOL BL STE 201 , TUMWATER WA 98501
Contractor License No: NORTHRI0000J
Phone: 360 485 -7436
Phone: 360 357 -9973
Expiration Date: 03/01/2012
DESCRIPTION OF WORK:
MODIFY DUCT LAYOUT AND ADD NEW THERMOSTAT CONTROLS
Value of Mechanical: $33,219.00
Type of Fire Protection:
Permit Center Authorized Signature:
Fees Collected:
$595.56
International Mechanical Code Edition: 2009
Date: J -' ( 7—
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit.
Signature:
Print Name:
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M10 -056 Printed: 05 -17 -2010
Parcel No.: 3523049087
Address:
Suite No:
Tenant:
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206- 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
17601 SOUTHCENTER PY TUKW
ASHLEY FURNTIURE
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M10 -056
ISSUED
04/23/2010
05/17/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox
keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information.
14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
doc: Cond -10/06
M10 -056 Printed: 05 -17 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page **
doc: Cond -10/06
M10 -056 Printed: 05 -17 -2010
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
Date:
ordinances governing
or local laws regulating
doc: Cond -10/06 M10 -056
Printed: 05 -17 -2010
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
Mechanical Permit No. Sri ,O
Project No.
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: �� 70/ 44-'7 �.GCn 7
Tenant Name: - '0.)4V /60- ✓S /A5Z/€7 fir",i7 :'c
Property Owners Name: j�./e / /a�S
Mailing Address: / 7 3/ FM /10/ ij �c/ Ora.," kis
King Co Assessor's Tax No.: 36-Z-30 ok
Suite Number: Floor:
New Tenant: ❑ Yes [;:[: "No
City
/CY 5
State
Zip
CONTACT PERSON Who do we contact when your permit is ready to be issued
Name:
To .-t PL Po,r-k5 Day Telephone: .5L0-- �' 0C
Mailing Address: SZO 7a/ o /✓r ". A Z'/
/ City State Zip
E -Mail Address: J /'k5 ��av�iti rre�c%,.,, c� �- u9-1-1 Fax Number: 3 ce— 7S L/- 7737
MECHANICAL CONTRACTOR INFORMATION
Company Name: /acv - 4 n Lie- c,.7 , 'G ',
Mailing Address: 5. -'-, z_ o- s c-6' Cr e-
Contact Person: Sae., ,e_ a5 0, bay A
E -Mail Address: //
Contractor Registration Number: /t/QI 774 1-- 9 0 J
City
Day Telephone:
Fax Number:
Expiration Date: 3 /a_
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: //�wi/dl � S e t Arc4,r/e.cA, ,
Mailing Address: 3939 (5P£ Cad y /4/1 • 6'- - " 1‘7L/c)
,[ City State Zip
Contact Person: )//74 '
E -Mail Address: G�c v/ GchOvci/ ?cC /� 4C. CG✓t---) Fax Number:
Day Telephone: 572 3L f C
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address: 4/6/0 Zo`1y. 5/. C7 6
Contact Person: t'°// s3 �SS
E -Mail Address: e� v; 'Jc e ,--t) ��? ya��c• . G'a�
H: \Applications\Forms - Applications On Line\2009 Applications \1 - 20099-- Mechanical Permit Application.doc
Revised: 1 -2009
bh
Ahz /75,, 5 /0 ,-tr 1 t ��i'
City tate Zip
Day Telephone: Z5-3- 353 - 0 5Z'
Fax Number: Z'73 _ 3 2..5--- C,✓ yC.,
Page 1 of 2
Valuation of Project (contractor's bid price): $ 33 2// Q
Scope of Work (please provide detailed information): ': A � C cJC/- A 7 0,// /1e
f�* rhd5t41- )11/(015
Use: Residential: New
Commercial: New
Replacement
Replacement
Fuel Type: Electric ❑ Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000
BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000
BTU
Appliance Vent
Hood and Duct
Emergency Generator
50+ HP /1,750,000 BTU
Repair or addition to
Heat/Refrig /Cooling System
Incinerator — Domestic
Other Mechanical
Equipment
Air Handling Unit <10,000
CFM
Incinerator — Comm/Ind
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ED NT:
Signature:
Print Name:
Mailing Address:
T i —,Es
520 / 6
Date: 7- -c2 —/G
Day Telephone: 360 —
City
6/4 9T-4o/
State Zip
Date Application Accepted:
N174,0
Date Application Expires:
io ithp
Staff Initials:
H:WpplicationsTorms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc
Revised: 1 -2009
bh
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 3523049087 Permit Number: M10 -056
Address: 17601 SOUTHCENTER PY TUKW Status: APPROVED
Suite No: Applied Date: 04/23/2010
Applicant: ASHLEY FURNTIURE Issue Date:
Receipt No.: R10 -00856 Payment Amount: $476.45
Initials: WER Payment Date: 05/17/2010 01:58 PM
User ID: 1655 Balance: $0.00
Payee: VAUGHN MECHANICAL INC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 25526 476.45
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - NONRES
000.322.102.00.00 476.45
Total: $476.45
P'YM E NT
RECEIVED
doc: Receipt -06 Printed: 05 -17 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 3523049087 Permit Number: M10 -056
Address: 17601 SOUTHCENTER PY TUKV/ Status: PENDING
Suite No: Applied Date: 04/23/2010
Applicant: ASHLEY FURNTIURE Issue Date:
Receipt No.: R10 -00692
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $119.11
Payment Date: 04/23/2010 10:18 AM
Balance: $476.45
VAUGHN MECHANICAL, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 25469 119.11
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 119.11
Total: $119.11
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 04 -23 -2010
INSPECTION RECORD AA 1(0
Retain a copy with permit i vt
117
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION +�
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Progt . / c
t)'A r"T I rn
Type of In n • • /I 1
/al f-, AA
i 1 (iu) ( f__S
pivigAft/a
P/Datewanted:
Date Called:
Special Instructions:
may, �, _ r ,
I
a.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION "
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
•
Proje t:
tAl
Type of Inspection:
Ad ress:
/1te�iJ sr�AT�
Date Called:
Special Instructions:
Date Wanted: (
l)
a m
p.m.
Requester:
Phone No:
9 51 - -s-o -9 -,d
Approved per applicable codes. ' El Corrections required prior to approval.
COMMENTS:
445r) IA.'S .
1
A
Date:
REINSPE-CTION FEE REQUIRED: Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to. schedule reinspection..
•
•
-q44
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
1("\
M 0-516
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 14
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project •
//
Type of Inspectimv
Address: i
7
Date Called:
Special Instructions:
Date Wanted:
K - / 0
'
x(10
m
p.m.
Requester:
Phone No:
EIApproved per applicable codes. El Corrections required prior to approval. /
COMMENTS:
r ' :v6 .J Are
o✓ Y
Inspe
date:
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
!Date:
INSPECTIONNO.
Ci
INSPECTION RECORD M 0 _ds
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION Z
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Pro g:
k k I�,) ,`t is
Typ of Inspection:
�.��G � e��
Address:
1'� �d SCJ
I
Date Cal d: �/1s(J ( .lt v.
Jc.Y
Special Instructions: P
Date
Wanted:
S-1‘./C) en:1"
Requester:
Phozne 5, _ S ?'off
0 Approved per applicable codes. Corrections required prior to approval. t
COMMENTS: PUT Ai( A f f (
r J;�'
At_ 1/N
--
-
1 2 k
;vb. :A\"Le
� ry 3)
1
41-
ilL
11-3
orti--; ,e 1
Z A-
,[3P• -Ci.n &
I 04
.I
Inspector:
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
-AA-3
oo-r-ie.edAy GEC
INSPECTION RECORD ��O a�
Retain a copy with permit 1"' •
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Pro'ect:
A SIA t�
FL) %A (‘T:1 r f
Type of Inspectipn:
(�c,
____
[.,
u _ a
, Qc,
Address:
v p
Date Calle
As
c
Special Instructions:
/
6 r
c a.pi,
Requester:
Phone Nom
r
r
l -0541' f
Approved per applicable codes.
Corrections required prior to approval. /7
COMMENTS:
CD
)-e_r\
v p
S €. AA 3 $
As
c
, "..s p e,.(3-- di AS'd c-
6 r
A- (k
.AJi
o f /UST- i-NJ 1 A 4
U A
r
r`
kn, AS
6-? Q.ii t`n cie e.or c
Inspec
Date: r
$60.00 REINSPECTION FEE R UIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blv ,., Suite 100. Call to schedule reinspection.
'Receipt No.:
'Date:
-1=P20
INSPECTION NO,
CITY OF TUKWILA BUILDING DIVISION rf.—
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2061431 -3670
INSPECTION RECORD
Retain a copy with permit
cA4
%4I9 -OSJO
PERMIT NO.
Proj ct:
A-1k LC/ ' ft. i i 4 (
ai a
TypeAf Inspection: — ` A / e j
Address:
P-u 3 S.4 t) S. c.,) Q e.dl d+ri;
Date Called:
Special Instructions:
/Date
Wanted: / `Al rn,
Requester:
Phone No:
253- Sol- a8.47-
❑ Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
.- 3,4, I+V•w• ct, -ner SA -125
Aru -2 .4. 0 cel l Weir s4.f f
P-u 3 S.4 t) S. c.,) Q e.dl d+ri;
(Cry »4 5.13- .4 &Jrne% R,t-t
-/f 0
/LTV — e S • 0 . f IY_Wei
J 7 v- (g J.0 - S. f. r.l Us
J/\JS4,41 ,A.ePf,,i,A(
/�
f`vi -.6 in � -A n(a /.�Je.,_ eG i €S7
rin,'-A cc__, 1
-
/
.., t A 1
Inspector:
(Date: s tr.,,'
1-1$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila Wa. 98188 - - 206- 575 -4407
Project:
-�
Fire Alarm:'
Hood & Duct: pi
Type of Inspection:
Pre- Fire: /Joe.
Permits: f
Address:
Sure #:
:.
c_..
c . _.f
Contact Berson
-1 - -c i:1.
Special Instructions:
Phone No.:
9
)
Approved per applicable codes.
Corrections required prior to approval
COMMENTS:
Sprinklers:
Fire Alarm:'
Hood & Duct: pi
Monitor: r , i - (.7,,,ffi.,.. ..
Pre- Fire: /Joe.
Permits: f
Occupancy Type: (V\
/ � 1
.+ +.o...-
,
! �...,; '�� sf
-e,./t./ '
/ f yt�,
1,)_5./4 e ,,� i - !
� � t
ti / .
` ✓' i •i.,f'-.
L V � v
,.,G'0,,..1.,,, ✓
�.
I,
r, s
Yea.
f l
4 1`ri
t{
i -i-"' .
f
� i
`} t� . F
.. ..� ' r 7 -L. ti-
'-
1
... .....- ?.._K.
(7,...-,
r
/ {j
X"�,`+jf f x, :� .,: i,,.:l. •+
(f
`?
t ."
is (C. . ^3[
ii t:AS S 1
ti,. Z"
a
✓J,
t
Needs Shift Inspection:'
Sprinklers:
Fire Alarm:'
Hood & Duct: pi
Monitor: r , i - (.7,,,ffi.,.. ..
Pre- Fire: /Joe.
Permits: f
Occupancy Type: (V\
Inspector:
Date: 9
rs..
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City o€ . M f Tlnance Department. Cali to schedule a reinspection.
Word/Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
INSPECTION NUMBER
CITY OF TUKWILA FIRE DEPARTMENT
INSPECTION RECORD
Retain a copy with permit
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Project:
'
,, h/ �- (.),/ e..
Type 9k Ins on: r
,04.5.. L ` , `� '1
Address:
Suite *:
, . / < r °"
Contact Person:
Special Instructions:
Occupancy Type:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre- Fire:
Permits:
Occupancy Type:
a A-b j
CO
ti' c. J r4:
(,h. vS C� 0„
tf
G.
. 4- CA-C i' ■ `p r' , 5
- �
..
tali
)oti
C
x
(Cif i 4.
6 . )AJ
6,
-.
y
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre- Fire:
Permits:
Occupancy Type:
Inspector:
Date:
H
. r1.
.•
E $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of T once Department. CaII to schedule a reinspection.
Word/Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
CITY OF TUKWILA - BUILDING DIVISION
2006 Washington State Nonresidential Energy Code Compliance Form
FILE COPY
Mechanical Summary
MECH -SUM
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
_
Project Address
i260/ �' y,
,/
Date
%v
, ic, it/4
/
For Building Dept. Use
Location
Ey, SJi'y�
Applicant Name:
//aa5A, Rec.(
l7
city
Applicant Address:
Applicant Phone:
�`
Project Description
Briefly describe mechanical
system type and features.
IEdes Plans
Include documentation requiring compliance with commissioning requirements, Section 1416.
Compliance Option
Simple System 0 Complex System 0 Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.)
Equipment Schedules
The following information is required to be incorporated with the mechanical equipment schedules on the
plans. For projects without plans, fill in the required information below.
Cooling Equipment Schedule
Equip.
ID
Brand Name
Model No.1
Capacity2
Btu /h
Total CFM
OSA CFM
or Econo?
SEER
or EER
IPLV3
Location
Ey, SJi'y�
7;:a an
city
�`
BUBL®IM
G DIMS(
f 1Al
M tt) .....0 5(iff
I
�_.._%�
t P;
i 10
..�li
,- = �_: Ili
Heating Equipment Schedule
Equip.
ID
Name
Model No.
No.1
Capacity2
Btu /h
Total CFM
OSA cfm
or Econo?
Input
p t Btuh
Output Btuh
y4
Efficiency4
��iiBrand
city
�`
BUBL®IM
G DIMS(
f 1Al
M tt) .....0 5(iff
I
�_.._%�
t P;
i 10
..�li
,- = �_: Ili
Fan Equipment Schedule
tqAi 1 L /01U
Equip.
ID
Brand
Model No.1
CFM
HP/BHP
Flow Controls
Location of Service
Name'
/�- 1ii'ST.�
city
�`
BUBL®IM
G DIMS(
f 1Al
M tt) .....0 5(iff
CITY OF TUKWILA - BUILDING DIVISION
_2006 Washingtop tatR,N• nresidential Energy Code Compliance Form
Mechanical Summary (back)
MECH -SUM
System Description
See Section 1421 for full description of
Simple System qualifications.
If Heating /Cooling
or Cooling Only:
• Constant vol?
•
Air cooled? • Packaged sys? • <20,000 Btuh?
❑ Split system?
Economizer included?
•
If Heating Only:
<70% outside air?
Is <5000 5000 cfm?
•
Decision Flowchart
Use this flowchart to determine if project qualifies for Simple System Option. If not, either the
Complex System or Systems Analysis Options must be used.
Heating Only
Heating /Cooling
or Cooling Only
Reference
Section 1421
Yes —
No
Reference
Section 14231
otal Ca .
wo economize
<240,000 Btuh
or 10 %?
Simple System
Allowed
(section 1420)
Use Complex
► Systems
(section 1430)
Complex Systems
Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex
Systems requirements are applicable to this project.
2006 Washington State Nonresidential Energy Code Compliance Form
Mechanical Permit Plans Checklist 1
2006 Washington State Nonresidential Energy Code Compliance Forms
MECH -CHK
Revised July 2007
Project Address
'Date
The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the
Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
(Component ,Information Required
Location
I on Plans
Building Department
Notes
HVAC REQUIREMENTS
(Sections 1401 -1424)
1411
Equipment performance
1411.4
Pkg. elec. htg.& clg.
List heat pumps on schedule
1411.1
Minimum efficiency
Equipment schedule with type, capacity, efficiency
1411.1
Combustion htg.
Indicate intermittent ignition, flue /draft damper & jacket loss
1412
HVAC controls
v1412.1
Y.1
Temperature zones
Indicate locations on plans
1412.2
Deadband control
Indicate 5 degree deadband minimum
1412.3
Humidity control
Indicate humidistat
1412.4
Automatic setback
Indicate thermostat with night setback and 7 diff. day types
1412.4.1
Dampers
Indicate damper location and auto. controls & max. leakage
1412.4.2
Optimum Start
Indicate optimum start controls
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
1412.6
Combustion htg.
Indicate modulating or staged control
ye,
1412.7
Balancing
Indicate balancing features on plans
1412.8
Ventilation Control
Indicate demand control ventilation for high- occupancy areas
1422
Thermostat interlock
Indicate thermostat interlock on plans
1423
Economizers
Equipment schedule
1413
Air economizers
1413.1
Air Econo Operation
Indicate 100% capability on schedule
1413.1
Wtr Econo Operation
Indicate 100% capacity at 45 degF db & 40 deg F wb
1413.2
Water Econo Doc
Indicate clg load & water econoe & clg tower performance
1413.3
Integrated operation
Indicate capability for partial cooling
1413.4
Humidification Indicate direct evap or fog atomization w/ air economizer
1414
Ducting systems
Y"
1414.1
Duct sealing
Indicate sealing necessary
y.e "2
1414.2
Duct insulation
Indicate R -value of insulation on duct
1415.1
Piping insulation
Indicate R -value of insulation on piping
1416
Completion Requirements
1416.2.1
Commissioning
Provide commissioning plan
�.QS
1416.2.2 -3
Sys.Bal & Func.Test
Indicate air and water system balancing & functional testing
Yel
1416.2.4
Commissioning
Indicate O &M manuals, record drawings, staff training
1416.2.5
Comm. Report
Indicate requirements for prelim. & final commissioning report
1434
Separate air sys.
Indicate separate systems on plans
Mechanical
Summary Form
Completed and attached. Equipment schedule with types,
input/output, efficiency, cfm, hp, economizer
SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454)
1440
Service water htg.
1441
Elec. water heater
Indicate R -10 insulation under tank
1442
Shut -off controls
Indicate automatic shut -off
1443
Pipe Insulation
Indicate R -value of insulation on piping
1452
Heat Pump COP
Indicate minimum COP of 4.0
1452
Heater Efficiency
Indicate pool heater efficiency
1453
Pool heater controls
Indicate switch and 65 degree control
2006 Washin ton State Nonresidential Eners Code Com • Iiance Form
•
Mechanical Permit Plans Checklist
2006 Washington State Nonresidential Energy Code Compliance Forms'
Mechanical - General Requirements
1411.1 General: Equipment shall have a minimum performance at the specified
rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a
nationally recognized certification program exists for a produ ct covered in Tables
14 -1A through 14 -1G, and it includes provisions for verification and challenge of
equipment efficiency ratings, then the product shall be listed in the certification
program.
Gas -fired and oil -fired forced air fumaces with input ratings > 225,000 Btu /h (65
kW) and all unit heaters shall also have an intermittent ignition or interrupted device
(IID), and have either mechanical draft (including power venting) or a flue damper. A
vent damper is an acceptable altemative to a flue damper for fumaces where
combustion air is drawn from the conditioned space. All fumaces with input ratings >
225,000 Btu/h (65 kW), including electric furnaces, that are not located within the
conditioned space shall have jacket losses not exceeding 0.75% of the input rating.
1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions
and procedures when available. Where no applicable procedures exist, data shall
be fumished by the equipment manufacturer.
1411.3 Combination Space and Sery ice Water Heating: For combination space
and service water heaters with a principal function of providing space heat, the
Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard
124 -1991. Storage water heaters used in combination space heat and water heat
applications shall have either an Energy FActor (EF) or a CAE of not less than the
following:
MECH -CHK
Revised July 2007
1411.4 Packag
equipment prow ding both heating and cooling with a total cooling capacity greater
than 20, Btu /h shall be a heat pump.
Exception: Unstaffed equipment shaelters or cabinets used solely for
personal wireless service facilities.
1412 Controls
1412.1 Temperature Controls: Each system shall be provided with at least one
temperature control device. Each zone shall be controlled by individual thermostatic
controls responding to temperature within the zone. At a minimum, each floor of a
building shall be considered as a separate zone.
1412.2 Deadband Controls: When used to control both comfort heating and
cooling, zone thermostatic controls shall be capable of a deadband of at least 5
degrees F within which the supply of heating and co oling energy to the zone is shut
off or reduced to a minimum.
Exceptions:
1. Special occupancy, special usage, or code requirements where
deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, if in the proposed building
energy analysis, heating and cooling thermostat setpoints are set to
the same temperature between 70 degrees F and 75 degrees F
inclusive, and assumed to be constant throughout the year.
3. Thermostats that require manual changeover between heating and
cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for adding
moisture, a humidistat shall be provided.
1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic
controls capable of accomplishing a reduction of energy use through control setback
or equipment shutdown during periods of non -use or altemate use of the spaces
served by the system. The automatic controls shall have a minimum seven -day
clock and be capable of being set for seven different day types per week. It must
retain programming and time for a power loss of 10 hours and include an accessible
manual override of up to 2 hours.
Exceptions:
1. Systems serving areas which require continuous operation at the
same temperature setpoint.
2. Equipment with full loa d demands of 2 kW (6,826 Btu/h) or less may
be controlled by readily accessible manual off -hour controls.
3. Systems controlled by an occupant sensor that is capable of shutting
the system off when no occupant is sensed for a period of up to 30
minutes.
4. Systems controlled solely by a manually operated timer capable of
operating the system for no more than two hours.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving
conditioned spaces shall be equipped with dampers which close au tomatically when
the system is off or upon power failure. Stair shaft and elevator shaft smoke relief
openings shall be equipped with normally open (fails to open upon loss of power)
dampers. These dampers shall remain closed until activated by the fire a larm
system or other approved smoke detection system.
Exceptions:
1. Systems serving areas which require continuous operation,
2. Combustion air intakes.
3. Gravity (nonmotorized) dampers are acceptable in buildings less
than 3 stories in height.
14148 Vent0ation controls tor High - occupancy areas: Demand control
ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design
occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are
served by systems with one or more of the following:
a. An air -side economizer,
b. Automatic modulating control of the outdoor air damper, or
c. A design outdoor airflow greater than 3000 cfm.
Exceptions:
1.Systems with energy recovery complying with Section 1436.
2. Multiple -zone systems without direct - digital control of individual zones
communicating with a central control panel.
3. Systems with a design outdoor airflow less than 1200 cfm.
4. Spaces where the supply airflow rate minus any makeup or outgoing
transfer air requirement is less than 1200 cfm.
1413 Air Economizers
1413.1 Operation: Air economizers shall be of automatically modulating outside and
return air dampers to provide 100 percent of the design supply air as outside air to
reduce or eliminate the need for mech anical cooling. Water economizers shall be
capable of providing the total concurrent cooling load served by the conneted
terminal equipment lacking airside economizer, at outside air temperatures of 45 °F
dry- bulb /40 °F wet -bulb and below. For this calculati on, all factors including solar and
internal load shall be the same as those used for peak Toad calculations, except for
the outside temperatures.
Exception: Water economizers using air- cooled heat rejection equipment
may use a 35 °F dry-bulb outside air to mperature for this calculation. This
exception is limited to a maximum of 20 tons per building.
1413.2 Documentation: Water economizer plans submitted for approval shall
include the following information:
1. Maximum outside air conditions for which economizer is sized to provide
full cooling.
2. Design cooling load to be provided by economizer at this outside air
condition.
3. Heat rejection and terminal equipment performance data including model
number, flow rate, capacity, entering and leaving temperature in full
economizer cooling mode.
1413.3 Integrated Operation: Air economizers shall be capable of providing partial
cooling even when additional mechanical cooling is required to meet the remainder
of the cooling load.
Exceptions:
1. • Individual, direct ex pansion units that have a rated capacity less than
65,000 Btu /h and use nonintegrated economizer controls that
preclude simultaneous operation of the economizer and mechanical
cooling.
2. Water - cooled water chillers with waterside economizer.
1413.4 Humid ification: If an air economizer is required on a cooling system for
which humidification equipment is to be provided to maintain minimum indoor
humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative
media or fog atomization type).
Exceptions:
1. Health care facilities where WAC 246 - 320 -525 allows only steam
injection humidifiers in ductwork downstream of final filters. 1412.6
Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Btu /h shall have modulating
or staged combustion control.
2. Systems with water economizer
3. 100% outside air systems with no provisions for air recirculation to the
central supply fan.
4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a
building's air economizer capacity as measured in cfm. This refers to
the system cfm serving rooms with stand alone or duct mounted
humidifiers.
1414 Ducting Systems
1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch
water column static pressure shall be sealed in accordance with Standard RS- 18.
Extent of sealing required is as follows:
1. Static pressure: 1/2 inch to 2 inches; seal transverse joints.
2. Static pressure: 2 inches to 3 inches; seal all transverse joints and
longitudinal seams.
3. Static pressure: above 3 inches; seal all transverse joints, longitudinal
seams and duct wall penetrations.
Duct tape and other pressure sensitive tape shall not be used as the primary
sealant where ducts are designed to operate at stati c pressures of 1 inch W.C. or
greater.
1414.2 Insulation: Ducts and plenums that are constructed and function as part of
the building envelope, by separating interior space from exterior space, shall meet all
applicable requirements of Chapter 13. These re quirements include insulation
installation, moisture control, air leakage, and building envelope insulation levels.
Unheated equipment rooms with combustion air louvers must be isolated from the
conditioned space by insulating interior surfaces to a minimu m of R -11 and any
exterior envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2,800 cfm of total supply air capacity shall be insulated
EF
CAE
< 50 gal storage
0.58
0.71
50 to 70 gal storage
0.57
0.71
> 70 gal storage
0.55
0.70
1. Special occupancy, special usage, or code requirements where
deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, if in the proposed building
energy analysis, heating and cooling thermostat setpoints are set to
the same temperature between 70 degrees F and 75 degrees F
inclusive, and assumed to be constant throughout the year.
3. Thermostats that require manual changeover between heating and
cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for adding
moisture, a humidistat shall be provided.
1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic
controls capable of accomplishing a reduction of energy use through control setback
or equipment shutdown during periods of non -use or altemate use of the spaces
served by the system. The automatic controls shall have a minimum seven -day
clock and be capable of being set for seven different day types per week. It must
retain programming and time for a power loss of 10 hours and include an accessible
manual override of up to 2 hours.
Exceptions:
1. Systems serving areas which require continuous operation at the
same temperature setpoint.
2. Equipment with full loa d demands of 2 kW (6,826 Btu/h) or less may
be controlled by readily accessible manual off -hour controls.
3. Systems controlled by an occupant sensor that is capable of shutting
the system off when no occupant is sensed for a period of up to 30
minutes.
4. Systems controlled solely by a manually operated timer capable of
operating the system for no more than two hours.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving
conditioned spaces shall be equipped with dampers which close au tomatically when
the system is off or upon power failure. Stair shaft and elevator shaft smoke relief
openings shall be equipped with normally open (fails to open upon loss of power)
dampers. These dampers shall remain closed until activated by the fire a larm
system or other approved smoke detection system.
Exceptions:
1. Systems serving areas which require continuous operation,
2. Combustion air intakes.
3. Gravity (nonmotorized) dampers are acceptable in buildings less
than 3 stories in height.
14148 Vent0ation controls tor High - occupancy areas: Demand control
ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design
occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are
served by systems with one or more of the following:
a. An air -side economizer,
b. Automatic modulating control of the outdoor air damper, or
c. A design outdoor airflow greater than 3000 cfm.
Exceptions:
1.Systems with energy recovery complying with Section 1436.
2. Multiple -zone systems without direct - digital control of individual zones
communicating with a central control panel.
3. Systems with a design outdoor airflow less than 1200 cfm.
4. Spaces where the supply airflow rate minus any makeup or outgoing
transfer air requirement is less than 1200 cfm.
1413 Air Economizers
1413.1 Operation: Air economizers shall be of automatically modulating outside and
return air dampers to provide 100 percent of the design supply air as outside air to
reduce or eliminate the need for mech anical cooling. Water economizers shall be
capable of providing the total concurrent cooling load served by the conneted
terminal equipment lacking airside economizer, at outside air temperatures of 45 °F
dry- bulb /40 °F wet -bulb and below. For this calculati on, all factors including solar and
internal load shall be the same as those used for peak Toad calculations, except for
the outside temperatures.
Exception: Water economizers using air- cooled heat rejection equipment
may use a 35 °F dry-bulb outside air to mperature for this calculation. This
exception is limited to a maximum of 20 tons per building.
1413.2 Documentation: Water economizer plans submitted for approval shall
include the following information:
1. Maximum outside air conditions for which economizer is sized to provide
full cooling.
2. Design cooling load to be provided by economizer at this outside air
condition.
3. Heat rejection and terminal equipment performance data including model
number, flow rate, capacity, entering and leaving temperature in full
economizer cooling mode.
1413.3 Integrated Operation: Air economizers shall be capable of providing partial
cooling even when additional mechanical cooling is required to meet the remainder
of the cooling load.
Exceptions:
1. • Individual, direct ex pansion units that have a rated capacity less than
65,000 Btu /h and use nonintegrated economizer controls that
preclude simultaneous operation of the economizer and mechanical
cooling.
2. Water - cooled water chillers with waterside economizer.
1413.4 Humid ification: If an air economizer is required on a cooling system for
which humidification equipment is to be provided to maintain minimum indoor
humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative
media or fog atomization type).
Exceptions:
1. Health care facilities where WAC 246 - 320 -525 allows only steam
injection humidifiers in ductwork downstream of final filters. 1412.6
Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Btu /h shall have modulating
or staged combustion control.
2. Systems with water economizer
3. 100% outside air systems with no provisions for air recirculation to the
central supply fan.
4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a
building's air economizer capacity as measured in cfm. This refers to
the system cfm serving rooms with stand alone or duct mounted
humidifiers.
1414 Ducting Systems
1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch
water column static pressure shall be sealed in accordance with Standard RS- 18.
Extent of sealing required is as follows:
1. Static pressure: 1/2 inch to 2 inches; seal transverse joints.
2. Static pressure: 2 inches to 3 inches; seal all transverse joints and
longitudinal seams.
3. Static pressure: above 3 inches; seal all transverse joints, longitudinal
seams and duct wall penetrations.
Duct tape and other pressure sensitive tape shall not be used as the primary
sealant where ducts are designed to operate at stati c pressures of 1 inch W.C. or
greater.
1414.2 Insulation: Ducts and plenums that are constructed and function as part of
the building envelope, by separating interior space from exterior space, shall meet all
applicable requirements of Chapter 13. These re quirements include insulation
installation, moisture control, air leakage, and building envelope insulation levels.
Unheated equipment rooms with combustion air louvers must be isolated from the
conditioned space by insulating interior surfaces to a minimu m of R -11 and any
exterior envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2,800 cfm of total supply air capacity shall be insulated
1
• 2. Combustion air intakes. 2006 Washington State Nonreside
3. Gravity (nonmotorized) dampers are acceptable in buildings less
than 3 stories in height.
4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief
outlets in the first story and levels below the first story of buildings
three or more stories in height.
1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply
air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum
start controls shall be designed to automatically adjust the start time of an HVAC
system each day to bring the space to desired occupied temperature levels
immediately before scheduled occupancy. The control algorithm shall, as a
minimum, be a function of the difference between space temperature and occupied
setpoint and the amount of time prior to scheduled occupancy.
1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include
microprocessor controls that minimize supplemental heat usage during start-up, set-
up, and defrost conditions. These controls shall anticipate need for heat and use
compression heating as the first stage of heat. Controls shall indicate when
supplemental heating is being used through visual means (e.g., LED indicators).
1412.6 Combustion Heating Equipment Controls: Combustion heating equipment
with a capacity over 225,000 Btulh shall have modulating or staged combustion
control. 000
EXCEPTIONS: 1. Boilers. 2. Radiant heaters.
1412.7 Balancing: Each air supply outlet or air or water terminal device shall have
a means for balancing, including but not limited to, dampers, temperature and
pressure test connections and balancing valves.
ntt Ef rWACKi13/G ITAP*M cRiailices to a minimu m of R -11 and any
exterior envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2,800 cfm of total supply air capacity shall be insulated
to a minimum of R -7 and are not considered building envelope. Other outside air
duct runs are considered building envelope until they,
1. connect to the heating or cooling equipment, or
2. are isolated from the exterior with an automatic shut -off damper complying
with Section 1412.4.1.
Once outside air ducts meet the above listed requirements, any runs within
conditioned space shall comply with Table 14 -5 requirements.
Other ducts and plenums shall be thermally insulated per Table 14 -5.
Exceptions:
1. Within the HVAC equipment.
2. Exhaust air ducts not subject to condensation.
3. Exposed ductwork within a zone that serves that zone.
1415 Piping Systems
1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6.
Exception: Piping installed within unitary HVAC equipment.
Water pipes outside the conditioned space shall be insulated in accordance with
Washington State Plumbing Code (WAC 51 -26)
1416 Completion Requirements (Refer to NREC Section 1416 and the Building
Commissioning Guidelines, published by the Building Commissioning Association,
for complete text and guidelines for building completion and commissioning
requirements.)
A-, Zc or C.
FILE CSI FY
Permit No
- REVIEWED FOR
CODE *MP HN ;E
MAME
Nr:1 12 2010
City ofTu� � �a
BUILDING DIVISION
Clrr: .�
APR 2 3 2010
PERMIT CSR
• PERMS COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -056
PROJECT NAME: ASHLEY FURNITURE
SITE ADDRESS: 17601 SOUTHCENTER PY
DATE: 04/23/10
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
04.1)0 t►�
Bulding Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
14f
Incomplete
DUE DATE: 04/27/10
Not Applicable
Permit Center Use Only •
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Building
Please Route IFIK Structural Review Required n No further Review Required ❑
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05/25/10
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Pfter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name Northwest Refrigeration Inc UBI No. 601437459
Phone 3603579973 Status Active
Address 5201 Capitol Blvd Ste 201 License No. N0RTHRI0000J
Suite /Apt. License Type Construction Contractor
City Tumwater Effective Date 9/11/2000
State Wa Expiration Date 3/1/2012
Zip 985010201 Suspend Date
County Thurston Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty 1
Specialty 2
Effective
Date
Expiration
Date
Status
N0RTHR'033BM
Northwest
Refrigeration
Construction
Contractor
Air
Conditioning
Other (Specify)
1/14/1997
8/20/2000
Archived
NORTHR'13605
Northwest
Refrigeration
Construction
Contractor
Mr
Conditioning
Commercial/ Industrial /Refrig
9/10/19878/20/1996
Until Cancelled
Archived
VAUGHR'131N1
Vaughn's
Refrigeration
Construction
Contractor
Air
Conditioning
Commercial/ Industrial /Refrig
8/21/19878/20/1988
01/25/2007
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
Murphie, Vaughn
President
01/01/1980
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
COLONIAL AM CAS &
SURETY OF MD
LPM4067166
09/07/2004
Until Cancelled
$12,000.0009/13
/2004
4
MID CENTURY INS CO
697000872
09/07/2001
Until Cancelled
09/07/2004
$12,000.0002/27 /2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
9
UNITRIN
PROPERTY &
CAS
KPP1004279
01/25/2010
01/25/2011
$1,000,000.00
01/20/2010
8
UNITRIN PROP
CAS INS
CAP2502071
01/25/2007
01/25/2010
$1,000,000.00
01/22/2009
7
UNITRIN PROP
& CAS
C4P0064062
01/25/2007
01/25/2008
$1,000,000.00
01/24/2007
6
MID-CENTURY
INS CO
602043509
01/25/2000
01/25/2008
$2,000,000.00
01/16/2007
3
CNA INS CO
1029693477
03/02/1998
Until Cancelled
Summons /Complaint Information
Cause
Complaint
Judgment
Status
Payment
Paid By
09 -2- 00919 -5
FERGUSON ENTERPRISES INC
Date: 04/16/2009
Amount: $5,726.66
Date:
Dismissed
Date:
https://fortress.wa.gov/lni/bbip/Print.aspx
05/17/2010
. i
RI1- RI- .iISTI- R S--N I- D L F SYMBOL MFR MODEL SIZE OBD QUANTITY NC
SA - 1 Shoemaker 901 Series 28 x 10 no 19 <30
SA - 2 Shoemaker 901 Series 12 x 4 no 3 <35
SA - 3 Shoemaker 901 Series 12 x 8 no 27 <35
SA - 4 Shoemaker 901 Series 6 x 6 no 6 <35
SA - 5 Shoemaker 901 Series 36 x 36 no 2 <35
RA - 1 Shoemaker 905 Series 30 x 30 no 1 <35
RA - 2 Shoemaker 905 Series 20 x 10 no 2 <35
RA - 3 Shoemaker 905 Series 48 x 36 no 7 <35
TG Shoemaker 901 Series 28 x 10 no 2 <30
FLEXIBLE & SPIRO DUCT DETAIL
V X 18 GAGE
BAND CLAMP
,_._
R S 2 I- D
SYMBOL MFR MODEL VOLTAGE QUANTITY
SD-1/RTU-1 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-2/RTU-2 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-3/RTU-3 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-4/RTU-4 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-5/RTU-5 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-6/RTU-6 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
Notes: SD-1 through S-6 to oe installeo in
Return Duct o-F o.11 Rooftop Units
r--'
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
.-.\ \H- \ DT D I- I- __,SE- R S: D
SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC
RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba
\OteS:
INCOMMING DUCT
///r---CEILING
DIFFUSER
CEILING DIFFUSER DETAIL
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
Klectrical
rrlumbing
50MsPiping
City of Tukwila
EARDING DIVISION
FELE
Permit No.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Cop and conditions is acknowledged:
By
Date:
City Of Tukwila
BUILDING DIVISION
\CT
S:
GENERAL NOTES
1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1
2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le
a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY
CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM,
4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE
5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50
6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON
PROJECT COMPLETION
COORDINATION NOTES
GENERAL CONTRACTOR
1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING,
FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO
PROVIDE SIZE AND LOCATION
2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL
MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED.
GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE
FRAMING OPENINGS.
3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED.
4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING
AS REQUIRED FOR MECHANICAL WORK,
5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL
EQUIPMENT,
6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE
ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS.
7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING
MEMBERS OF MECHANICAL EQUIPMENT.
8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA
MATERIAL AS REQUIRED FOR HVAC INSTALLATION.
PLUMBING CONTRACTOR
1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH
AIR INTAKES,
2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE
ELECTRICAL CONTRACTOR
1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS
AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT.
2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS
WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS,
3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH
4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH
PIECE OF MECHANICAL EQUIPMENT.
5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS,
6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT,
COMPLETION
AS-BUILT RECORD DRAWINGS
1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1
TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE.
0 & M MANUALS
1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.2 TO OWNER,
SYSTEM - BALANCING
1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING
OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER.
1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1
AND 1416,4,2
2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE
FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS,
VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND
TEST REPORT,
3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE
ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE,
AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING
PER WSEC 1413
4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.42,2.1
5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND
FILED WITH THE OWNER,
STAT S/- 1 - 1D._
NCITES
SYMBOL MFR TYPE MODEL # QUANITY
T HONEYWELL TOUCHSCREEN T 7581 6
NOTES _ all Thermostats to be installed in Network Room
- all Thermostats and Temp.-Sensors to be installed 54a AFF
.. __
S- \S R ' S'.- 11- D L
SYMBOL. AREA SERVED MFR MODEL QUANTITY
S Showroom HONEYWELL WR 21-23 6
NOTES - the Temp,-Sensors will be installed like shown in the Detail Page
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MA 1. 2 2010
kW--
City of Tukwila
BUILDING DIVISION
CITY 0
APR 2 3 2010
PERMIT CENTER
LA
p\,\. 0 --- 0 5g
- EP SPIR DUCT AS CLOSE AS P-SSIBLE IC
CEILING
z
(17)1
LJ
APPROVED
(/)
uJ
z
< Z
Pq
0
LY 11
<:(4
1-1
(/) U
LA
C=4 d
U
< m
06
• cp
cf 0)
Nt 1_1.1 cu
uI
co
1 3 co
C3 0 CO
C>
w U co
-1-›
▪ ni
cu
-P
:
'4- 0
_C Lfl
•ct* U
CD
c) 5
‘,1
I 2,
CY) c
1.0
z
I- .
.._, \
\ 1
1- D
R I
SYMBOL A
AREA M
MFR M
MODEL T
TOTAL AIRFLOW CFM O
OUTSIDE AIR CFM E
ECONOMIZER
RTU-1 S
SHOWROOM T
TRANE Y
YCD300B 1
10,000 3
3,300 Y
YES E
EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006
RTU-2 S
SHOWROOM T
TRANE Y
YCD300B 1
10,000 3
3,300 Y
YES E
EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006
RTU-3 S
SHOWROOM T
TRANE Y
YCD300B 1
10,000 3
3,300 Y
YES E
EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006
RTU-4 S
SHOWROOM T
TRANE Y
YSC120A 4
4,000 1
1,300 Y
YES E
EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006
RTU-5 S
SHOWROOM T
TRANE Y
YSC120A 4
4,000 1
1,300 Y
YES E
EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006
RTU-6 S
SHOWROOM T
TRANE Y
YSC120A 4
4,000 1
1,300 , Y
YES E
EXISTING UNIT, INSTALLED UNDER DIFFERENT PERMIT IN 2006
RI1- RI- .iISTI- R S--N I- D L F SYMBOL MFR MODEL SIZE OBD QUANTITY NC
SA - 1 Shoemaker 901 Series 28 x 10 no 19 <30
SA - 2 Shoemaker 901 Series 12 x 4 no 3 <35
SA - 3 Shoemaker 901 Series 12 x 8 no 27 <35
SA - 4 Shoemaker 901 Series 6 x 6 no 6 <35
SA - 5 Shoemaker 901 Series 36 x 36 no 2 <35
RA - 1 Shoemaker 905 Series 30 x 30 no 1 <35
RA - 2 Shoemaker 905 Series 20 x 10 no 2 <35
RA - 3 Shoemaker 905 Series 48 x 36 no 7 <35
TG Shoemaker 901 Series 28 x 10 no 2 <30
FLEXIBLE & SPIRO DUCT DETAIL
V X 18 GAGE
BAND CLAMP
,_._
R S 2 I- D
SYMBOL MFR MODEL VOLTAGE QUANTITY
SD-1/RTU-1 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-2/RTU-2 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-3/RTU-3 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-4/RTU-4 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-5/RTU-5 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-6/RTU-6 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
Notes: SD-1 through S-6 to oe installeo in
Return Duct o-F o.11 Rooftop Units
r--'
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
.-.\ \H- \ DT D I- I- __,SE- R S: D
SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC
RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba
\OteS:
INCOMMING DUCT
///r---CEILING
DIFFUSER
CEILING DIFFUSER DETAIL
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
Klectrical
rrlumbing
50MsPiping
City of Tukwila
EARDING DIVISION
FELE
Permit No.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Cop and conditions is acknowledged:
By
Date:
City Of Tukwila
BUILDING DIVISION
\CT
S:
GENERAL NOTES
1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1
2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le
a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY
CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM,
4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE
5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50
6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON
PROJECT COMPLETION
COORDINATION NOTES
GENERAL CONTRACTOR
1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING,
FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO
PROVIDE SIZE AND LOCATION
2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL
MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED.
GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE
FRAMING OPENINGS.
3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED.
4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING
AS REQUIRED FOR MECHANICAL WORK,
5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL
EQUIPMENT,
6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE
ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS.
7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING
MEMBERS OF MECHANICAL EQUIPMENT.
8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA
MATERIAL AS REQUIRED FOR HVAC INSTALLATION.
PLUMBING CONTRACTOR
1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH
AIR INTAKES,
2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE
ELECTRICAL CONTRACTOR
1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS
AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT.
2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS
WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS,
3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH
4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH
PIECE OF MECHANICAL EQUIPMENT.
5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS,
6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT,
COMPLETION
AS-BUILT RECORD DRAWINGS
1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1
TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE.
0 & M MANUALS
1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.2 TO OWNER,
SYSTEM - BALANCING
1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING
OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER.
1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1
AND 1416,4,2
2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE
FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS,
VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND
TEST REPORT,
3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE
ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE,
AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING
PER WSEC 1413
4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.42,2.1
5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND
FILED WITH THE OWNER,
STAT S/- 1 - 1D._
NCITES
SYMBOL MFR TYPE MODEL # QUANITY
T HONEYWELL TOUCHSCREEN T 7581 6
NOTES _ all Thermostats to be installed in Network Room
- all Thermostats and Temp.-Sensors to be installed 54a AFF
.. __
S- \S R ' S'.- 11- D L
SYMBOL. AREA SERVED MFR MODEL QUANTITY
S Showroom HONEYWELL WR 21-23 6
NOTES - the Temp,-Sensors will be installed like shown in the Detail Page
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MA 1. 2 2010
kW--
City of Tukwila
BUILDING DIVISION
CITY 0
APR 2 3 2010
PERMIT CENTER
LA
p\,\. 0 --- 0 5g
- EP SPIR DUCT AS CLOSE AS P-SSIBLE IC
CEILING
z
(17)1
LJ
APPROVED
(/)
uJ
z
< Z
Pq
0
LY 11
<:(4
1-1
(/) U
LA
C=4 d
U
< m
06
• cp
cf 0)
Nt 1_1.1 cu
uI
co
1 3 co
C3 0 CO
C>
w U co
-1-›
▪ ni
cu
-P
:
'4- 0
_C Lfl
•ct* U
CD
c) 5
‘,1
I 2,
CY) c
1.0
z
FLEXIBLE & SPIRO DUCT DETAIL
V X 18 GAGE
BAND CLAMP
,_._
R S 2 I- D
SYMBOL MFR MODEL VOLTAGE QUANTITY
SD-1/RTU-1 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-2/RTU-2 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-3/RTU-3 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-4/RTU-4 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-5/RTU-5 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
SD-6/RTU-6 Shoemaker DH100ACDC 120/240 VAC 1 OR SIMILAR
Notes: SD-1 through S-6 to oe installeo in
Return Duct o-F o.11 Rooftop Units
r--'
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
.-.\ \H- \ DT D I- I- __,SE- R S: D
SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC
RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba
\OteS:
INCOMMING DUCT
///r---CEILING
DIFFUSER
CEILING DIFFUSER DETAIL
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
Klectrical
rrlumbing
50MsPiping
City of Tukwila
EARDING DIVISION
FELE
Permit No.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Cop and conditions is acknowledged:
By
Date:
City Of Tukwila
BUILDING DIVISION
\CT
S:
GENERAL NOTES
1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1
2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le
a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY
CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM,
4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE
5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50
6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON
PROJECT COMPLETION
COORDINATION NOTES
GENERAL CONTRACTOR
1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING,
FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO
PROVIDE SIZE AND LOCATION
2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL
MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED.
GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE
FRAMING OPENINGS.
3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED.
4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING
AS REQUIRED FOR MECHANICAL WORK,
5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL
EQUIPMENT,
6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE
ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS.
7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING
MEMBERS OF MECHANICAL EQUIPMENT.
8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA
MATERIAL AS REQUIRED FOR HVAC INSTALLATION.
PLUMBING CONTRACTOR
1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH
AIR INTAKES,
2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE
ELECTRICAL CONTRACTOR
1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS
AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT.
2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS
WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS,
3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH
4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH
PIECE OF MECHANICAL EQUIPMENT.
5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS,
6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT,
COMPLETION
AS-BUILT RECORD DRAWINGS
1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1
TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE.
0 & M MANUALS
1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.2 TO OWNER,
SYSTEM - BALANCING
1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING
OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER.
1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1
AND 1416,4,2
2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE
FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS,
VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND
TEST REPORT,
3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE
ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE,
AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING
PER WSEC 1413
4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.42,2.1
5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND
FILED WITH THE OWNER,
STAT S/- 1 - 1D._
NCITES
SYMBOL MFR TYPE MODEL # QUANITY
T HONEYWELL TOUCHSCREEN T 7581 6
NOTES _ all Thermostats to be installed in Network Room
- all Thermostats and Temp.-Sensors to be installed 54a AFF
.. __
S- \S R ' S'.- 11- D L
SYMBOL. AREA SERVED MFR MODEL QUANTITY
S Showroom HONEYWELL WR 21-23 6
NOTES - the Temp,-Sensors will be installed like shown in the Detail Page
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MA 1. 2 2010
kW--
City of Tukwila
BUILDING DIVISION
CITY 0
APR 2 3 2010
PERMIT CENTER
LA
p\,\. 0 --- 0 5g
- EP SPIR DUCT AS CLOSE AS P-SSIBLE IC
CEILING
z
(17)1
LJ
APPROVED
(/)
uJ
z
< Z
Pq
0
LY 11
<:(4
1-1
(/) U
LA
C=4 d
U
< m
06
• cp
cf 0)
Nt 1_1.1 cu
uI
co
1 3 co
C3 0 CO
C>
w U co
-1-›
▪ ni
cu
-P
:
'4- 0
_C Lfl
•ct* U
CD
c) 5
‘,1
I 2,
CY) c
1.0
z
r--'
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
.-.\ \H- \ DT D I- I- __,SE- R S: D
SYMBOL MFR MODEL MODULE SIZE QUANTITY TOTAL AIRFLOW TOTAL SP SUPPLY SP RETURN SP NC
RTU-5 TITUS CSR-P 48 X 48 1 MAX 6000 CFM .675 .332 -.343 46dba
\OteS:
INCOMMING DUCT
///r---CEILING
DIFFUSER
CEILING DIFFUSER DETAIL
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
Klectrical
rrlumbing
50MsPiping
City of Tukwila
EARDING DIVISION
FELE
Permit No.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Cop and conditions is acknowledged:
By
Date:
City Of Tukwila
BUILDING DIVISION
\CT
S:
GENERAL NOTES
1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1
2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le
a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY
CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM,
4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE
5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50
6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON
PROJECT COMPLETION
COORDINATION NOTES
GENERAL CONTRACTOR
1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING,
FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO
PROVIDE SIZE AND LOCATION
2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL
MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED.
GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE
FRAMING OPENINGS.
3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED.
4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING
AS REQUIRED FOR MECHANICAL WORK,
5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL
EQUIPMENT,
6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE
ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS.
7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING
MEMBERS OF MECHANICAL EQUIPMENT.
8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA
MATERIAL AS REQUIRED FOR HVAC INSTALLATION.
PLUMBING CONTRACTOR
1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH
AIR INTAKES,
2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE
ELECTRICAL CONTRACTOR
1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS
AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT.
2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS
WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS,
3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH
4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH
PIECE OF MECHANICAL EQUIPMENT.
5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS,
6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT,
COMPLETION
AS-BUILT RECORD DRAWINGS
1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1
TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE.
0 & M MANUALS
1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.2 TO OWNER,
SYSTEM - BALANCING
1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING
OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER.
1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1
AND 1416,4,2
2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE
FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS,
VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND
TEST REPORT,
3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE
ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE,
AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING
PER WSEC 1413
4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.42,2.1
5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND
FILED WITH THE OWNER,
STAT S/- 1 - 1D._
NCITES
SYMBOL MFR TYPE MODEL # QUANITY
T HONEYWELL TOUCHSCREEN T 7581 6
NOTES _ all Thermostats to be installed in Network Room
- all Thermostats and Temp.-Sensors to be installed 54a AFF
.. __
S- \S R ' S'.- 11- D L
SYMBOL. AREA SERVED MFR MODEL QUANTITY
S Showroom HONEYWELL WR 21-23 6
NOTES - the Temp,-Sensors will be installed like shown in the Detail Page
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MA 1. 2 2010
kW--
City of Tukwila
BUILDING DIVISION
CITY 0
APR 2 3 2010
PERMIT CENTER
LA
p\,\. 0 --- 0 5g
- EP SPIR DUCT AS CLOSE AS P-SSIBLE IC
CEILING
z
(17)1
LJ
APPROVED
(/)
uJ
z
< Z
Pq
0
LY 11
<:(4
1-1
(/) U
LA
C=4 d
U
< m
06
• cp
cf 0)
Nt 1_1.1 cu
uI
co
1 3 co
C3 0 CO
C>
w U co
-1-›
▪ ni
cu
-P
:
'4- 0
_C Lfl
•ct* U
CD
c) 5
‘,1
I 2,
CY) c
1.0
z
INCOMMING DUCT
///r---CEILING
DIFFUSER
CEILING DIFFUSER DETAIL
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
Klectrical
rrlumbing
50MsPiping
City of Tukwila
EARDING DIVISION
FELE
Permit No.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Cop and conditions is acknowledged:
By
Date:
City Of Tukwila
BUILDING DIVISION
\CT
S:
GENERAL NOTES
1. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS 1
2. ALL DUCT GAUGES AND SUPPORTS PER elkIROwiiigfulgg, e2.4, 0 Le
a INSULATE SUPPLY AND RETURN DUCT WORK PER imM@.- WASHINGTONASTATE ENERGY
CODE. SEE PLANS FOR DETAILS. 2' LINER & WRAP SHALL INSULATE TO R - 7 MINIMUM,
4, ALL DUCTS TO BE SEALED PER THE 2001 WASHINGTON STATE ENERGY CODE
5. MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THAN 50
6. MCS TO AIR BALANCE ALL SYSTEMS TO WITHIN 10% OF DESIGN AIRFLOW UPON
PROJECT COMPLETION
COORDINATION NOTES
GENERAL CONTRACTOR
1. GENERAL CONTRACTOR TO CUT AND PROVIDE OPENINGS FOR ALL ROOFTOP, CEILING,
FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING, MCS TO
PROVIDE SIZE AND LOCATION
2. GENERAL CONTRACTOR TO PROVIDE FRAMED OPENINGS WHERE REQUIRED FOR ALL
MECHANICAL PENETRATIONS, INCLUDING HEADERS IF REQUIRED.
GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATIONS WITH MCS BEFORE
FRAMING OPENINGS.
3, GENERAL CONTRACTOR TO FURR IN DUCTWORK AS REQUIRED.
4, GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING AND PAINTING
AS REQUIRED FOR MECHANICAL WORK,
5, GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL
EQUIPMENT,
6, GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY MCS, PROVIDE
ALL CANT STRIPS AND CURB INSULATION , AND SEAL AGAINST LEAKS.
7, GENERAL CONTRACTOR TO PROVIDE STRUCTURE FOR MOUNTING AND HANGING
MEMBERS OF MECHANICAL EQUIPMENT.
8. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING OF T-BAR CEILING AND EXTRA
MATERIAL AS REQUIRED FOR HVAC INSTALLATION.
PLUMBING CONTRACTOR
1, PLUMBING CONTRACTOR TO OFFSET VENTS 10` MINIMUM FROM ALL HVAC FRESH
AIR INTAKES,
2. MCS TO FURNISH AND INSTALL ALL CODENSATE DRAIN LINES PER CODE
ELECTRICAL CONTRACTOR
1. ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS
AND MOTOR STARTERS FOR MECHANICAL EQUIPMENT.
2. ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS
WITH MCS MECHANICAL PLAN AND WITH FIELD CONDITIONS,
3, ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH
4, ELECTRICAL CONTRACTOR TO PROVE 120V SERVICE OUTLETS WITHIN 25 FEET OF EACH
PIECE OF MECHANICAL EQUIPMENT.
5. MCS TO INSTALL ALL 24 VOLT - LOW VOLTAGE WIRING FOR THERMOSTATS,
6. ELECTRICAL CONTRACTOR TO INSTALL ALL LINE VOLTAGE WIRING AND CONDUIT,
COMPLETION
AS-BUILT RECORD DRAWINGS
1, PROVIDE RECORD DRAWINGS WITH MINIMUM INFORMATION SPECIFIED IN WSEC 1416.1
TO OWNER WITHIN 90 DAYS OF SYSTEM ACCEPTANCE.
0 & M MANUALS
1, PROVIDE OPERATING AND MAINTANANCE MANUALS WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.2 TO OWNER,
SYSTEM - BALANCING
1. PROVIDE A WRITTEN BALANCING REPORT DOCUMENTING TESTING AND BALANCING
OF AIR SYSTEMS AS SPECIFIED IN WSEC 1416.3 TO OWNER.
1, ALL HVAC CONTROL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH WSEC 1416,4.1
AND 1416,4,2
2. FOR ALL HVAC UNITS, VERIFY THAT THERMOSTAT ACTIVATES HEATING MODE,COOLING MODE
FOR ALL AVAILABLE STAGES, AND THAT FAN IS SET TO RUN DURING ALL OCCUPIED HOURS,
VERIFY INITIAL PROGRAMMING OF THERMOSTAT, VERIFY UNIT OPERATION PER MCS START AND
TEST REPORT,
3, FOR ALL HVAC UNITS WITH ECONOMIZERS, VERIFY THAT SYSTEM CONTROLS ACTIVATE
ECONOMIZER DAMPERS WHEN OUTDOOR SETPOINT MAKES FREE COOLING AVAILABLE,
AND THAT DAMPERS MODULATE IN CONJUNCTION WITH MECHANICAL COOLING STAGING
PER WSEC 1413
4, A PRELIMINARY COMMISSIONING REPORT SHALL BE PREPARED, WITH MINIMUM INFORMATION
SPECIFIED IN WSEC 1416.42,2.1
5, A FINAL COMMISSIONING REPORT PER WSEC 1416.4,222 SHALL BE PREPARED AND
FILED WITH THE OWNER,
STAT S/- 1 - 1D._
NCITES
SYMBOL MFR TYPE MODEL # QUANITY
T HONEYWELL TOUCHSCREEN T 7581 6
NOTES _ all Thermostats to be installed in Network Room
- all Thermostats and Temp.-Sensors to be installed 54a AFF
.. __
S- \S R ' S'.- 11- D L
SYMBOL. AREA SERVED MFR MODEL QUANTITY
S Showroom HONEYWELL WR 21-23 6
NOTES - the Temp,-Sensors will be installed like shown in the Detail Page
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MA 1. 2 2010
kW--
City of Tukwila
BUILDING DIVISION
CITY 0
APR 2 3 2010
PERMIT CENTER
LA
p\,\. 0 --- 0 5g
- EP SPIR DUCT AS CLOSE AS P-SSIBLE IC
CEILING
z
(17)1
LJ
APPROVED
(/)
uJ
z
< Z
Pq
0
LY 11
<:(4
1-1
(/) U
LA
C=4 d
U
< m
06
• cp
cf 0)
Nt 1_1.1 cu
uI
co
1 3 co
C3 0 CO
C>
w U co
-1-›
▪ ni
cu
-P
:
'4- 0
_C Lfl
•ct* U
CD
c) 5
‘,1
I 2,
CY) c
1.0
z
S- \S R ' S'.- 11- D L
SYMBOL. AREA SERVED MFR MODEL QUANTITY
S Showroom HONEYWELL WR 21-23 6
NOTES - the Temp,-Sensors will be installed like shown in the Detail Page
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MA 1. 2 2010
kW--
City of Tukwila
BUILDING DIVISION
CITY 0
APR 2 3 2010
PERMIT CENTER
LA
p\,\. 0 --- 0 5g
- EP SPIR DUCT AS CLOSE AS P-SSIBLE IC
CEILING
z
(17)1
LJ
APPROVED
(/)
uJ
z
< Z
Pq
0
LY 11
<:(4
1-1
(/) U
LA
C=4 d
U
< m
06
• cp
cf 0)
Nt 1_1.1 cu
uI
co
1 3 co
C3 0 CO
C>
w U co
-1-›
▪ ni
cu
-P
:
'4- 0
_C Lfl
•ct* U
CD
c) 5
‘,1
I 2,
CY) c
1.0
z
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MA 1. 2 2010
kW--
City of Tukwila
BUILDING DIVISION
CITY 0
APR 2 3 2010
PERMIT CENTER
LA
p\,\. 0 --- 0 5g
- EP SPIR DUCT AS CLOSE AS P-SSIBLE IC
CEILING
z
(17)1
LJ
APPROVED
(/)
uJ
z
< Z
Pq
0
LY 11
<:(4
1-1
(/) U
LA
C=4 d
U
< m
06
• cp
cf 0)
Nt 1_1.1 cu
uI
co
1 3 co
C3 0 CO
C>
w U co
-1-›
▪ ni
cu
-P
:
'4- 0
_C Lfl
•ct* U
CD
c) 5
‘,1
I 2,
CY) c
1.0
z
EXI T.
ELE
I q
(-0
1 •s.,11
SA-4
75CFM
PC
4
SA-3
400CFM
10"
12"
RT1,1
RTU4
FT111.4
Irrua
ITTL.
SA-3
300CFM
•
10"
•
I)J
1,1
16" •
6"
1
24^
SD-4
IL
• 6"
1
SA4
75CFM
RA-1 F
t• A11=11
10"
SA-3
400CFM
1
SA-3
500CFM
10^
10"
RTU-4
•
U-4
SA-3
400CFM
ENTRY
100
SA-3
500CFM
1
if I
o
(I 1
q I
4 I
a 1
SA-4
100CFM
SA-3
500CFM
36" SD1 10"
RA-3
14"
SA-3 SA-3
1
500CFM 500CFM
18"
rti
RTU-tr
•
24"x40"
SA-1
1200CFM
SA-3
500CFM
18"
SA-1
'600CFM
'
110
,
:11'1
,1.•••
•',1'
:1j•
;
rT
SA-4 1 12"
50CFM
.14•4
_Q"
16";
Fri
rr-.1
12"
UU U
SA-3 ,SA-3
401C 1 NI
1111
16" I D_
121,
,
SA-4
50CFM L---
SA-4 4 ■s 1^21 150CFM
1071 j. 47._
SA-3
__I I
LE
1 Li
14"
SA-3
500CFM
10^
^-1
SA-3
500CFM
SA-1
1200CFM
; SA-1
1200CFM
,•77
1
ft!
• I 010,
# •
#4
"4
SA-3
500CFM
10"
„SA-1
1200CFM
7
18"
1
4,12/2/4/4,?2/4"&i&23 r,":04',"/.&4fiZ,•2,2.&:2;f&71.Z4V,,,,,..I21.11.!
! 1-- , '----7-• - ....,-V--,V,
■
1 , • 1
. , • ,
• 1 1112,V12,z.1/21•,•4,•••,,w/404,,,,,,Weezzzzw"la•Z•;•'42Zztily.:2.,,,"o/YA11,/,:f-4/../.z.,=,/,,,,,,V•YA,/,,,.Y",,,/,/ -1,749/4,24.62Zare.:2
• 1
•
Concentric Discharge and Return
RTU-5
SA-3
500CFM
SALES
1 26
SA-3
500CFM
10"
RTU-2 •
PIA-3
24"
SD-2
SA-1
1200CFM
RA-3
1
24"
RTUr2
10"
SA-1
1200CFM
18" !
L
7
SA-3
500CFM
1
SA-3
500CFM
SA-3
500CFM
RU-6
20"
4:
18^
14"
SD-6
RA-3
24"
L
is."11
18"
SA-3
RA-3 600CFM 600CFM
1 12"
T- 11:"
;--,
SA-3
SA-1
:1200CFM
1
ELECTRONICS
1
•
RA-3
RTU-6
SD-3
SA-3
600CFM
CLEARANCE
1 1 7
30"
I I
RA-3
RTU-3
SA-1
1200CFM
SA-1
1200CFM
SA-1
1200CFM
TG-1
\ 7G-11
36"
I SA-1
•
1200CFM
34"
SA-1 FL
1200CFM
1200CFM
SA-1 FL
1200CFM
Ji
,
'•••••-,
14"
11 SA-2•1
150CF
REVIEWED FOR
CODE COMPLIANCE
APPROVED
IV( 1 2 2010
•
•
•
City of Tukwila
BUILDING DIVIRIM
crry Fi
i-dri 2010
PERMIT C
z
0
c
411
LLI to
v-
ct 4
00
APPROVED
SHEET NO.
MI00-.054)