Loading...
HomeMy WebLinkAboutPermit M10-058 - JAVI'S MEXI MARTJAM'S MEXI MART 14816 TUKWILA INTERNATIONAL BL M10 -058 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 0041000142 Address: 14816 TUKWILA INTERNATIONAL BL TUKW Project Name: JAVI'S MEXI MART Permit Number: M10 -058 Issue Date: 07/15/2010 Permit Expires On: 01/11/2011 Owner: Name: STEINBERG DOUG Address: 26519 CAMBRIDGE DR , KENT WA 98032 Contact Person: Name: KAI WONG Address: PO BOX 80563 , SEATTLE WA 98108 Email: KAIMTC @YAHOO.COM Contractor: Name: MONARCH TRADING CORP Address: PO BOX 80563 , SEATTLE WA 98108 Contractor License No: MONARTC065Q 1 Phone: 206 -763 -6161 Phone: 206 - 763 -6161 Expiration Date: 03/06/2011 DESCRIPTION OF WORK: INSTALL 15 FOOT HOOD SYSTEM Value of Mechanical: $6,000.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $252.56 International Mechanical Code Edition: 2009 Date: 07//51/d I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constriction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: /7(..(//e) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -058 Printed: 07 -15 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS ParcelNo.: 0041000142 Permit Number: M10 -058 Address: 14816 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 04/29/2010 Tenant: JAVI'S MEXI MART Issue Date: 07/15/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 14: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. doc: Cond -10106 M10 -058 Printed: 07 -15 -2010 ►, w4� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ht43..//www.ci.tukwila.wa.us 15: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 16: Local U.L. central station supervision is required. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: Art electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 21: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -058 Printed: 07 -15 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: '(/i,� -- L/U AiJ0' Date: 7/(J(/0 doc: Cond -10/06 M10 -058 Printed: 07 -15 -2010 Site Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us I l44 Mechanical Permit No. tittO '- OS Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Tenant Name: gIv� et r t King Co Assessor's Tax No.: 0011 — 4 (L Suite Number: Floor: New Tenant: ❑ Yes Property Owners Name: Mailing Address: City State Zip 032- CONTACT PERSON - Who do we contact when you permit is ready to be issued Name: jC� / 0/ Wei Mailing Address: /9' e - A6 erX g'Os C; E -Mail Address: t Mt( ( if, h o' • co 1.1,1 MECHANICAL CONTRACTOR INFORMATION Day Telephone: - G' 76. H 6t . 7 et/r9 rd/r, City St ate Zip Fax Number: 2-' / 76{-f- 676 p Company Name: /)' (d /1.0 rt /i ciG 21, Mailing Address: 74 c Contact Person: �i (4J d /V6-7 E -Mail Address: t' V V tC (6, r s • CO /ii Contractor Registration Number: 01�) k TC 06 •Q City State Zip Day Telephone: 2 el(' �3. 67. • Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: State Contact Person: E -Mail Address: HAApplications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application doc Revised. 1 -2009 bh City Day Telephone: Fax Number: Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ t 000-c Scope of Work (please provide detailed information): 4- -'v 5+ tio001 Use: Residential: New Commercial: New Replacement Replacement Fuel Type: Electric ❑ Gas )31/ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat'Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD°NG,Q,WNER OR AUTHORIZED AGENT: \ s� Signature: Print Name: L L ) Mailing Address: CoC -r-4 PG' t • s Si Date: e;)! Day Telephone: y o L' 7K c ?/ - ‹cf--1-1(/=, y (c-/) State Zip Date Application Accepted: �_�c - r 0 Date Application Expires: iv"' )---,-1-( U Staff Initials: (I Q H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 0041000142 Permit Number: M10 -058 Address: 14816 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 04/29/2010 Applicant: JAVI'S MEXI MART Issue Date: Receipt No.: R10 -01322 Initials: User ID: Payee: LAW 1632 Payment Amount: $202.05 Payment Date: 07/15/2010 02:40 PM Balance: $0.00 KAI F WONG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 015856 ACCOUNT ITEM LIST: Description 202.05 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 202.05 Total: $202.05 PAYMENT RECEIVED doc: Receipt -06 Printed: 07 -15 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 0041000142 Permit Number: M10 -058 Address: 14816 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 04/29/2010 Applicant: JAN'S MEXI MART Issue Date: Receipt No.: R10 -00737 Initials: User ID: Payee: WER 1655 Payment Amount: $50.51 Payment Date: 04/29/2010 01:55 PM Balance: $202.05 KAI WONG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 029766 ACCOUNT ITEM LIST: Description 50.51 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 50.51 Total: $50.51 AY E : RECEIVE doc: Receipt -06 Printed: 04 -29 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 /0 /d -oS5 Project* !1F> A (//S r I ,Tj . pe of Inspection: i4/iq f L Address: / Ii 6 1-16 Date Called: .... Special Instructions: Date Wanted: 7 Requester` Phone No: .2o6,-356 -o4/ -• 1540.5.,pproved per applicable codes. El Corrections required prior to approval. COMMENTS: rr+;f (719m, /f'/- � fr iA)a/ spec r: Date:, 3 -le) 0.00 REINSPECTfpN FEE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ' INSPECTION RECORD Retain a copy with permit INSP N0. PERMIT NO. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Prejeet r '_ 1 f - e of Inspectio : Ad ress: 48 E _ Apo" .114 ate Called: / _. _ . Special Instructions: /9 7 1 �� �$ Date Wanted: a.m. Requester: Phone No: -3/(0 -40019 • • ❑ Approved per applicable codes. Corrections required prior to approval. /- • COMMENTS: f - t,�.?"- - "-wit _ Apo" .114 A..r. s r ~ `�y .t - ' -- - - - _ fir -.__ ny� • IDatE3 z ECTION FEE REQUIRE Prior to next inspection. fee must be 300 Southcenter Blvd.. uite 10 Call to schedule reinspection. -. INSPECTION NO. INSPECTION RECORD M o- OsY Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project: - T e of Inspection: Address: Hg'( 'r __& Date CaI ed: Special Instructions: vl' n 1 T �' t(/�" 4 Date Wanted: _ 2 2 _ r 0 /J a.m., Requester: Phone No: 2,0 (0, -3 g(7 -ov/7 Approved per applicable codes. 0 Corrections required prior to approval. 6, COMMENTS: nspect 00 REINSPECTION F REQUIRiD. Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 7►- tz— 0 Re'eipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Project: r.. , .AU G m,r`IL, (Y'\Ad 1 Type of Inspection: / at(1-+ i 0 Ft) kyti v.1 I. - twiti e. 0 bklieJ - Address: 114 61L -riR Date Called: Special Instructions: Date Wanted: "7 20— 10 aim p.m. Requester: Phone No: 0200 — 3C(o -Oof -7 proved per applicable codes. ❑ Corrections required prior to approval. 'OMMENTS: -.7- ;.,,,. Y.;!'- 0 Ft) kyti v.1 I. - twiti e. 0 bklieJ - 1 ,...) - NI f_1 P. A Inspec r: 1 Date -2 -28 - D 60.0 REINSPECTION F E REQUIREJD. Prior to inspection, fee must be pai. at 6300 Southcenter Blvd., Suit 100. Call to schedule reinspection. pt No.: Date: r • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit • - _i713 ii4/0 '051 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 ' 206- 575 -4407 Project: wJi 5 Type of I specti o/: / o i i= p . / Xv.44 Address: 1 q q? o Suite #: Contact Person. + % C�!�zlD � /L/�e 2 Fire Alarm: Special Instructions: Phone No.: ,;;2 of ) 63502 - `` a `f $ Hood & D uct: FKApproved per applicable codes. Corrections required prior to approval: COMMENTS: (t -/t er dp & - ALP 47)„,,J2. 8L A d" ek_ • Needs Shift Inspection: ►✓ Sprinklers: 1 • Firs:: Fire Alarm: 1 -_ Hood & D uct: • Monitor: 4to.-.41.• Cir., 4-- Pre -Fire: _ Permits: Occupancy Type: p, inspector: 1 :r Date: • i 11 bb• • Firs:: • •. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection: Word /Inspection Record Form.Doc 1/13/06 :A: T.F.D. Form F.P. 113 INSPECTION NUMBER INS PEC7OlRECORD- Retain a copy with permit AA O—O 7674-- ma. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila W& 98188 _ 206 -575 -4407 Project: 1 -415 Sprinklers: Type of nspection: 1004 i va Address: / y42 Suite #: T�f� Contact Pe n: t 3vi k.. re/ . kdk dht.. Special Instructions: Occupancy Type: Phone No.: Approved per applicable codesP Corrections required prior to approval. COMMENTS: — !or?, e ` n1 viz w O is tAle &F rl I he I p il e le.y.v. ie IAA& R I) o — J4/td €e q ,/a a , ' ao Ai , r. 0.� 4 (A u % 14... / SAM/' m� eery/ / e. A s•s 4 r 4e:.P " Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: a Inspector: ,.-rr,.. kl4 - y I Date: 7/2/0.0 Hrs. it. r" Pt $80.00 RE SPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Departrnent. Call to schedule a reinspection. Word /Iiisi5ection Re ord Form.Doc 1/13/06 Form F.P. 113 Structural Calculations FILE COPY For Permit No Kitchen Hood Project Location: JAVI'S MEXIMART 14820 Tukwila- international Blvd. Prepared by: Yi Zhang, Date: June 13, 2010 INCOMPLETE MIOO58 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 132010 City of Tukwila BUILDING DIVISION RECEIVED JUN 14 2010 PERMIT CENTER [ IV K 't 11\-4,6VI4 TiAlcvik wti-\ n A 1 1/1/+-61rtil 0,*(C114 5kAokA) o ad 2.5 . r — f - s - e k s s wt. i c., 1 0 (La $ .-._. 1 , 1:-......, , .17- a g FA, = 1 , C (c4 5 -;,1-1,tv.e ,,:-.; C-i. p) , eI I. hi H2 ,- 1 " • C-11 r t - 1,44.crz- 7-; o -- c-; - 0 Cike,f/V c-5k1u5 r 2x 12. 161 4, 24- Z1,9 *-c_ worst ro V\i =7.( 2-c)- = tit ± 2-- = 2O 2- E I 1 t 06 o fr:• ,q Ic GT /06 •X ( 2- ik- 1,1 -e,(0 o0 Load L',- roof Jo te,ts 2 4 E. Lai of: ti.) V t t-, L a „/ / 4- 2- 'K. F A;2/ 127'. ) AJ oF wit Y" but) atitite (016,, , — 1"; ( 1...AJC061 4C re.0...,)<, tzl. tYz' 4- c WA) 5 v 4 25 ...2. N / , " ) ; f 1-f- 2. 1 i , .41 ,k ca r ( 7-1-7 - FP vx 1, CP5 If °Jr -77 9, 3 p Tr 1/91.9 t If; , — , tk z , 0 T. o fey- C014 5--e-KVC-t ) ,t),14--at7PcjiUr (It 2 , , • p,4-X 1,0 c_I,0 X 10.0,9 / ( xs ° / '17 9 .77.- 4/- T -2Pc p Jo • 0 K Lox -7 Nts. X' • 0 'FT -1) rN-- p (2d n I,)oOD , cRecL,-)5 C p(1-C c m t4T, tA47 Te4f41614 (0.<3 p 24 X !t =) 15 -' I5 UCE sly = 15r-eL x = 2-94 IL �2q > 2 wooD ScgCci) To EA, tsr, 4T1,0t honb T o I a4ec. Zt'emslay = I13? a IL 3/2 •X (,6 HcOp . I /4x !Vat' woos LAQ Sr( & 303 I,6',o� 72$6 v v 2 Y o S ,„„' \\A-1/12lx . \poop To A, 4TH, A ; (20o F NFL-uL) vii5,(ItAp-5,01,3 A3s c-t,t F 41p1.-„ EA D uAtir, un"q ItJ61 A NJ& H co p MFR A (We-tiiit/K- kift\J-) vu/(4) 126 wooD Nevi vas t771*-`,&\• I A—A %do KTf�oH H 00 D To Z X I, K w(l /4xIYi Lai 6 s p 6" c: , ;((o 1",c, it' lio,116‘AET, Ty WOOD 5(,K/J0 To , (-7Twi) ATTIVA1 Hoop To EXIST. Wk(L ,0 -21 I NO1YS amJ 151x3 -J 1SIx3 0 l I g 0. I Ll oaVnO NSYldS 15)x3 dONS Ab7OO117 3186,1 0113 M0OM 0111 ‘Sal ll 1131003 AYk190 JS 952 H71133 31BY1 xaOM 31BY1 x3JOM £SIX 3S 921 (15tx 3) 01003 M -x1YM 347131 831003 303A N3d0 JS 1 aFRS 8000 1SIx3 ,L -,m Y331Y 031'071d BONS A833080/030.1 1.51%) so o a 4 FILE COPY Permit No., Fire Barrier Dust Wrap 20A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions , GA psi NFPA 96 0 ^A Coo pSanu 1993 Edition Evawauon Report 5901 Complies with Complies with International Uni(onn Mechanical Code Mechanical Code CORRECTION LTR# M(OO59 REVIEWED FOR CODE COMPLIANCE APPRAVED JUL 13 2010 City of Tukwila BUILDING DIVISInN RECEIVED JUL 12 2010 PERMIT CENTER 1. Product Description 3M" Fire Barrier Duct Wrap 20A is a fire resistant wrap consisting of a patented inorganic blanket encapsulated with a scrim - reinforced foil. It is used to fire rate commercial kitchen grease ducts and is a proven alternative to 1 or 2 hour fire resistant rated shaft enclosures. This non - asbestos wrap contains a safer fiber construction' and installs easily because of its high flexibility and strength. 3M Fire Barrier Duct Wrap 20A is a two -layer fire resistant wrap system that has passed the ICBO AC101 internal test which simulates a grease duct fire. With its excellent insulating capabilities, it is an ideal choice for tight spaces because it protects combustible constructions at zero clearance. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealants used in combination 3M Fire Barrier Duct Wrap 20A provide an effective firestop when the duct penetrates fire rated walls and floors. Features • Listed to pass the internal grease duct fire test, ICBO AC101 • Zero clearance to combustibles for congested spaces • High flexibility for installation ease • Foil encapsulated with unique center overlap seam for blanket strength, protection and less dust • Safer fiber construction' Has been demonstrated to be soluble in the lungs according to EU guidelines 67/548/EWG, Note Q for bio persistence. 2. Applications 3M Fire Barrier Duct Wrap 20A is an ideal fire resistive enclosure for commercial kitchen grease ducts. It is a proven performance alternative to a 1 or 2 hour fire resistant rated shaft enclosures and provides zero clearance to combustible construction at overlap or collar. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant is used in combination with 3M Fire Barrier Duct Wrap 20A to firestop the duct when the duct penetrates fire rated floors and walls. 3. Availability Product Unit Size Units/ ctn. Wt./ ctn. 3M Fire Barrier Duct Wra s 20A Roll 2 in. x 24 in. x 20 ft. 50 mm x 60,9 cm x 609 cm 1 70 lbs. 31 k• 3M Fire Barrier Duct Wra i 20A Roll 2 in. x 48 in. x 20 ft. 50 mm x 121 cm x 609 cm 1 140 lbs. 63 k. 3M Fire Barrier Duct Wrap 20A Collar Roll 2 in. x 6 in. x 20 tt. (50 mm x 152 cm x 609 cm) 4 70 lbs. 31 kg 4. Typical Physical Properties Blanket Color: gray /green Weight: Page 2 1.83 lbs. /sq. ft. (8.93 kg /sq. m) 5. Performance 3M Fire Barrier Duct Wrap 20A has been tested in accordance with the following: ASTM C,411 ASTM C 518 ASTM E 84 ASTM E 119 ASTM E 136 ASTM E 814 ICBO AC101 Internal Surface Burning Characteristics (ASTM E 84) Foil Encapsulated Blanket: Flame Spread: 0 Smoke Developed: 0 Blanket: Flame Spread: 0 Smoke Developed: 0 Thermal Conductivity Temperature °F ( °C) btu•inJ(hr.•ft'•F) 500 (260) 0.417 1000 (537) 0.922 1500 (815) 1.69 1800 (982) 2.27 For technical data and properties of 3M Fire Barrier 1000 N /S, 1003 S/L and 2000+ Silicone Sealants see separate product data sheets available from your 3M representative. Grease Duct Listings Fire Enclosure System Omega Point Lab. Design Nos. Resistive Duct System Through - Rating Penetration System 1 or 2 hours 2 layers of 3M Fire Barrier GO 531 F FS 557 W Duct Wrap 20A , 3 in. FS 558 F (76 mm) perimeter and longitudinal overlaps FS 559 W FS 560 F FS 561 F FS 562 W FS 563 W Code Compliance 3M Fire Barrier Duct Wrap 20A complies with requirements of the following codes: NFPA 96, 1998 Edition Uniform Mechanical Code Section 507.6 International Mechanical Code Section 506.3.11 Uniform Building Code Section 711 ICBO ES Evaluation Report No. 5907 This is only a partial list of code compliance. For the latest code and approval information go to www.3rn.com /firestop or speak to your authorized 3M distributor or sales representative at (800) 328 -1687. 6. Installation Techniques 3M Fire Barrier Duct Wrap 20A system should be installed in accordance with the following installation instructions. Material and Equipment • 3M Fire Barrier Duct Wrap 20A blanket, 2 in. (50 mm) thick, 24 in. (60 cm) or 48 in. (121 cm) wide, 20 ft. (609 cm) standard length. The 48 in. (121 cm) wide blanket helps to minimize waste. • Aluminum foil tape. • Minimum 3/4 in. (19 mm) wide filament tape. • Carbon steel or stainless steel banding material, minimum 1/2 in. (12,7 mm) wide, minimum 0.015 in. (0,38 mm) thick, with steel banding clips. • Hand banding tensioner, crimping tool, and banding cutter. • Minimum 12 gauge copper- coated steel insulation pins; galvanized steel speed clips, minimum 1 -1/2 in. (38 mm) square or 1 -1/2 in. (38 mm) dia. round, or equivalent sized insulated cup -head pins; capacitor discharge stud gun. • Access door hardware: four galvanized steel thread rods, 1/4 in. (6 mm) diameter by 4 -1/2 in. to 5 in. long (114 mm to 127 mm) with 1/4 in. (6 mm) wing nuts and 1/4 in. (6 mm) washers: 4 in. (102 mm) long steel hollow tubing to fit threaded rods. • Minimum 4.0 Ib. (1,8 kg) density mineral wool or scrap pieces of 3M Fire Barrier Duct Wrap 20A blanket • 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant. Storage The 3M Fire Barrier Duct Wrap 20A and 3M Fire Barrier 1000 N /S, 1003 S/L and 2000+ Silicone Sealants must be stored in a dry warehouse environment. Pallets should not be stacked. Preparatory Work: 3M Fire Barrier Duct Wrap 20A is installed with common tools, such as knives, banders and capacitor discharge guns for applying insulation pins. In order to install the duct firestop system, the surfaces of all the openings and penetrating items need to be clean, dry, frost free and free of dust. Method: To minimize waste, 3M Fire Barrier Duct Wrap 20A material should be rolled out tautly before measuring. General instructions for installing the 3M Fire Barrier Duct Wrap 20A includes a two -layer wrap construction applied directly to the duct. The first layer or interior wrap of 3M Fire Barrier Duct Wrap 20A shall be cut to a length sufficient to wrap com- pletely around the perimeter of the duct, plus provide an overlap of not less than 3 in. (76 mm). Aluminum foil tape is used to seal cut edges of the blanket. Use filament tape to temporarily hold first layer blanket in place. The second layer is applied over the first layer using one of the following methods. Banding is only applied to the exterior layer. There are three (3) approved installation techniques for installing the 3M Fire Barrier Duct Wrap 20A (See Figures 1A -1D and Figures 2A -2D): 1. Telescoping 3 in. (76 mm) Overlap Wrap With the telescoping overlap wrap method, each blanket overlaps one adjacent blanket, and each blanket has one edge exposed and one edge covered by the next blanket as shown in Figure 1A and 1B. The visible edges of the perimeter overlaps all point in the same direction. The next adjacent interior wrap of 3M Fire Barrier Duct Wrap 20A shall be cut to completely wrap around the perimeter of the duct with enough excess to provide an overlap of not less than 3 in. (76 mm). A minimum 3 in. (76 mm) longitudinal overlap onto the previous adjacent wrap is required on both layers. The second layer or exterior wrap of 3M Fire Barrier Duct Wrap 20A should be cut to sufficient length to wrap completely around the perimeter of the interior wrap with sufficient excess to provide an overlap of not less than 3 in. (76 mm). The 3M Fire Barrier Duct Wrap 20A to be installed as the exterior layer shall be cut, if needed, and properly located to ensure that the longitudinal overlap joints of the exterior layer of blanket are staggered 10 -1/2 in. (26,7cm) from those of the interior layer. Aluminum foil tape is used to seal any cut edges of the blanket. 2. Checkerboard 3 in. (76 mm) Overlap Wrap With the 3 in. (76 mm) checkerboard overlap wrap method, blankets with both edges exposed alternate with blankets with covered edges, as shown in Figure 1C. The visible edges of the perimeter overlaps alternate their directions and appear on every other blanket. 3. Butt Joint With Collar With the butt joint and collar overlap method, adjacent blankets are butted tightly together and 6 in. (152 mm) wide collar of 3M Fire Barrier Duct Wrap 20A is centered over the joint, overlapping each blanket by 3 in. (76 mm) as shown in Figure 1D. In all three overlap techniques the perimeter overlap can occur at any location on the duct. The blanket is mechanically attached to the duct by steel banding or by welded insulation pins and clips for all three installation methods listed above. For Banding Only (See Figures 1A to 1D) Filament tape can be used to temporarily hold the blanket in place until the banding is applied. The steel banding is applied around the duct 1 -1/2 in. (38 mm) from each edge of the blanket, and 10 -1/2 in. (26,7 cm) maximum centers. The banding is placed around the exterior layer of material and tightened so as to sufficiently hold the 3M Fire Barrier Duct Wrap 20A in place against the duct, compressing the foil but not cutting the foil. Page 3 Additional Pinning to Prevent Sagging of the Wrap: For Ducts 24 in. (60 cm) and larger in width, additional pins are needed to support the blanket on the bottom horizontal surface and on the outside face of a vertical duct run. Space pins a maximum of 10 -1/2 in. (26,7 cm) apart in the direction of the - blanket width, and a maximum of 12 in. (30 cm) apart in the direction of the blanket length. Refer to paragraph below for more information on Mechanical Fastening with Pins. For Mechanical Fastening with Pins Only (See Figure 2A to 2D) Insulation pins are welded to the duct in the centers of the overlaps a minimum of 1 -1/2 in. (38 mm) from each edge of the blanket, and spaced a maximum of 8 in. (27 mm) on center along perimeter overlap, and a maximum of 10 -1/2 in. (38 mm) on center along longitudinal overlaps. The blanket is impaled over the pins and held in place by galvanized speed clips. Insulation pins that extend beyond the blanket wrap shall be turned down to eliminate sharp points. Insulated cup -head pins can be used at the same spacing requirements of the insulation pins. NOTE: Support hangar systems do not need to be wrapped provided the hangar rods are at least a minimum of 3/8 in. (9,53 mm) diameter and spaced a maximum of 60 in. (152,4 cm) on center along the length of the duct. Use a minimum 2 in. x 2 in. x 1/4 in. (50 mm x 50 mm x 6,35 mm) steel angle steel support channel or SMACNA equivalent support system. Access Door Installation (See Figure 3) Four galvanized steel threaded rods, 1/4 in. diameter (6,35 mm) by 6 -1/2 in. to 7 in. long (165 mm to 177 mm) are welded to the duct at the corners of the door opening. Four steel tubes, each 5 in. to 7 in. (127 mm to 165 mm) long, are placed over the rods to act as protection for the 3M Fire Barrier Duct Wrap 20A when fastening the door. Four insulation pins are welded to the door panel for installation of the blan- ket. One layer of 3M Fire Barrier Duct Wrap 20A is cut so as the approximately the same size as the access door panel and impaled over the insulation pins. It is essential that this layer fit tightly against the wrap surrounding the access door opening with no through openings. A second layer of 3M Fire Barrier Duct Wrap 20A is cut so as to overlap the first layer by a minimum of 1 in. (25 mm) on all sides. A third layer of 3M Fire Barrier Duct Wrap 20A is cut to overlap the second layer by 1 in (25 mm) on all sides. The layers are impaled over the welding pins and all layers are Page 4 locked in place with galvanized speed clips. Pins that extend beyond the outer layer of 3M Fire Barrier Duct Wrap 20A shall be turned down to avoid sharp points on the door. The insulated door panel is placed over the threaded rods and held in place with washers and wing nuts. The details are shown in Figure 3. Penetrations (See Figures 4A to 4D) When the duct penetrates a fire rated wall, ceiling or floor, an approved firestop system must be employed. Figures 4A to 4D illustrate typical conditions. To firestop the wrapped duct, follow the installation parameters detailed in the following Omega Point Laboratories, Inc. systems: FS 557 W, FS 558 F, FS 559 W, FS 560 F, FS 561 F, FS 562 W, FS 563 W. Other Applications Refer to Figures 5, 6, 7, 8 and 9 for additional typical conditions. 7. Maintenance No maintenance is required when installed in accordance with the 3M Installation Instructions. Once installed, if any section of the 3M Fire Barrier Duct Wrap 20A is damaged so that the blanket is damaged, the following procedures will apply: • The damaged section should be removed by cutting the steel banding or removing the clips holding it in place. • A new section of the same dimension should be cut from a roll of 3M Fire Barrier Duct Wrap 20A, either 24 in. (60,9 cm) or 48 in. (121 cm) wide. • The new section should be placed and fitted ensuring the same overlap that existed previously. • The steel banding should be placed around the material and tensioned so as to sufficiently hold the 3M Fire Barrier Duct Wrap 20A in place. • If the blanket has not been damaged but the foil has ripped, seal the rip with aluminum foil tape. 8. Purchase Information 3M Fire Barrier products are available through a network of nationwide distributors. For information on where to buy, go to www.3m.com /firestop. 9. Safe Handling Information Consult Material Safety Data Sheet prior to handling and disposing of 3M Fire Barrier Duct Figure 1A 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Telescoping Wrap Technique With Banding For Ducts 24 inches (60,9 cm) or Less Wrap 20A. 1A. First Layer 3M Fire Barrier Duct Wrap 20A 1 B. Second Layer 3M Fire Barrier Duct Wrap 20A 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap System integrity is limited by quality of installation. Page 5 Figure 1B Telescoping Overlap Wrap Option Cross Sectional View 3" (76 mm) 1-1/2" (38 mm) 0 3" (76 mm) L-1 /2" (38 rnm) 1 A I 21" (53,3 cm) Typ. Figure 1C Checkerboard Overlap Wrap Option Cross Sectional View 3" (76 mm) 1 -1/2" (38 mm) 16 � 3" (76 mm) 1 -1/2" (38 mm) 21" (53,3 cm) Typ. Figure 1D Butt Joint With Collar Option Cross Sectional View 6" (152 mm) 3" (76 mm) 1 -1/2" (38 mm_l_ 1 -1/2" (38 mm) 1A " (30,4 cm) 1A. First Layer 3M Fire Barrier Duct Wrap 20A 1 B. Second Layer 3M Fire Barrier Duct Wrap 20A 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap 5. 6 in. (152 mm) Wide Collar: Prefabricated 3M Fire Barrier 20A Collar 6. Firmly Butted Joint System integrity is limited by quality of installation. Page 6 Figure 2A 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease,Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Telescoping Wrap Technique With Weld Pins Only 1A. First Layer 3M Fire Barrier Duct Wrap 20A 1 B. Second Layer 3M Fire Barrier Duct Wrap 20A 2. 1 -1/2 in. Square (38 mm) or 1 -1/2 Dia. (38 mm) Galvanized Speed Clips 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap System integrity is limited by quality of installation. Page 7 Figure 2B Telescoping Overlap Wrap Option Cross Sectional View 3" (76 mm) 1-1/2" (38 mm) • 1B 3" (76 mm) 1 -1/2" (38 mm) 1 A 21" (53,3 cm) Typ. Figure 2C Checkerboard Overlap Wrap Option Cross Sectional View 3" (76 mm 1-1/2" (38 mm 1B 3" (76 mm) 1 -1/2" (38 mm) 21" (53,3 cm) Typ. Figure 2D Butt Joint With Collar Option Cross Sectional View 6" (152 3" (76 mm) 1 —1 /2" (38 Ommj 2 mm) 1-1/2" (38 mm) 12' (30,4 cm) 1A. First Layer 3M Fire Barrier Duct Wrap 20A 1 B. Second Layer 3M Fire Barrier Duct Wrap 20A 2. 1 -1/2 in. Square (38 mm) or 1 -1/2 Dia. (38 mm) Galvanized Speed Clips 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap 5. 6 in. (152 mm) Wide Collar: Prefabricated 3M Fire Barrier 20A Collar 6. Firmly Butted Joint System integrity is limited by quality of installation. Page 8 Figure 3 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Access Door System 1. Access Hole 2. 114 in. (6 mm) Dia. All Threaded Rods 3. Access Cover — 16 Gauge 4. Insulation Pins — Welded 5. First Layer 3M Fire Barrier Duct Wrap 20A Cut Same Size As Cover 6. Second Layer 3M Fire Barrier Duct Wrap 20A with 1 in. (25mm) Overlap On All Sides 7. Third Layer 3M Fire Barrier Duct Wrap 20A with 1 in. (25mm) Overlap On All Sides of Previous Layer 8. Speed Clips 9. Aluminum Tape Covering All Exposed Edges 10. Spool Pieces For Threaded Rods 11. 1/4 in. (6mm) Diameter Wing Nuts System integrity is limited by quality of installation. 6" Page 9 Figure 4A 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration. Systems 4 -1/2 inch (11,4 cm) Concrete Floor or Wall 1. Floor /Ceiling or Wall Assembly 2. Duct 3A. Two Layers 3M Fire Barrier Duct Wrap 20A 3B Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To Both Sides of Wall System integrity is limited by quality of installation. Page 10 Omega Point Laboraties, Inc. Through Penetration Systems FS 560 F FS 562 W Figure 4B 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems Fire -Rated Gypsum Wallboard L1 3" (76 mm 3" 1A. Studs 1 B. Gypsum Wallboard 2. Duct 3A. Two Layers 3M Fire Barrier Duct Wrap 20A 3B. Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N/S or 2000+ Silicone Sealant System integrity is limited by quality of installation. H (76 mm) Omega Point Laboraties, Inc. Through Penetration Systems FS 557 W FS 559 W Page 11 • Figure 4C 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems 4 -1/2 inch (11,4 cm) Concrete Floor or Wall -.4 1--- — Cr t--' 1. Floor /Ceiling or Wall Assembly 2. Duct 3A. Each Two Layers 3M Fire Barrier Duct Wrap 20A — Terminated on Side of Floor or Wall Penetration. 3B Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To Both Sides of Wall System integrity is limited by quality of installation. Page 12 Omega Point Laboraties, Inc. Through Penetration Systems FS 561 F FS 563 W Figure 4D 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 Hour Through Penetration Systems Fire -Rated Wood /Gypsum - Floor /Ceiling Assembly 1. Fire -rated Floor /Ceiling Assembly 2. Duct 3A. Two Layers 3M Fire Barrier Duct Wrap 20A 38 Banding or.Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant System integrity is limited by quality of installation. Omega Point Laboraties, Inc. Through Penetration Systems FS 558 F Page 13 3 99 Figure 5 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems Suggested 1 or 2 Hour Three Sided Wrap 76 mm) (6 ) f 1. Concrete Slab 2. Two Layers 3M Fire Barrier Duct Wrap 20A 3. Concrete Fasteners - Minimum 1/4 in. (6 mm) Dia. Steel Concrete Anchors 4. 1/8 in. (3mm) Thick x 2 in. -3in. (50mm - 76mm) Wide Bar Stock Perforated 12 in. (30 cm) O.0 5. Duct 6. Banding 7. Banding Clips Page 14 Figure 6 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems Suggested 1 or 2 Two Hour Two Sided Wrap 3" (76 mm) 4 4 4 Lt W 1. Concrete Slab 2. Two Layers 3M Fire Barrier Duct Wrap 20A 3. Concrete Fasteners - Minimum 1/4 in. (6 mm) Dia. Steel Concrete Anchors 4. 1/8 in. (3 mm) Thick x 2 in. -3 in. (50 mm — 76 mm) Wide Bar Stock Perforated 12 in. (30 cm) O.C. 5. Duct 6. Banding 7. Banding Clips System integrity is limited by quality of installation. Page 15 Figure 7 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Exhaust Hood 1. 2. 3. 4. Hood Two Layers 3M Fire Barrier Duct Wrap 20A 6 in. (152 mm) Minimum Overlap Banding Page 16 r-. E N L) Figure 8 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Roof Vent a 1. Duct 2. Roof Assembly 3. Roof Flashing 4. Vent Flashing 5. Two Layers 3M Fire BarrierDuct Wrap 20A 6. Firestopping System for Rated Roof Assemblies Only Page 17 Figure 9 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Vertical Support 3" (76 mm) MIN. TYP. 1. First Layer 3M Fire Barrier Duct Wrap 20A 2. Second Layer 3M Fire Barrier Duct Wrap 20A 3. Mechanical Fasteners and Washers 4. Duct 5. Rated Floor /Ceiling 6. Firestopping System 7. Banding 8. Support Channel Page 18 Warranty and Limited Remedy. This product will be free from defects in material and manufacture for a peri- od of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user's method of application. If this 3M product is proved to be defective within the warranty period stated above, your exclusive remedy and 3M's sole obligation shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the product. Limitation of Liability. Except where prohibited by law, 3M will not be liable for any loss or damages arising from the use of this 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. 3M Specified Construction Products Department 3M Center 223 -2N -21 St. Pail, MN 55144 -1000 (800) 328-1687 Printed in U.S.A. 3M 2001 98- 0400 - 5055 -5 (July 2001) Transmittal Date: To: Cc July 5, 2010 Allen Johnnessen, plan examiner City of Tukwila Kai Wong From: Young Kim — NW Architecture, LLC. Project No. /Name: M10 -058: Javi Mexi Mart @ 14816 Tukwila Intl Blvd. Total # of pages: 1 (including this page) Subject: Review Correction from June 16, 2010 Allen, could you please review below; 1.Professional's stamp: Response: Resubmitted drawings for the hood are signed by architect. 2. The mech. equipment on the roof location/ 10' separation between exhaust fan and make -up fan: Response: the roof equipment is located away from roof edge, north: 19', east: 25', thus we do not need the guardrail. There is separation min. 10' distance between exhaust and make -up fans. See M1.0 and M1.1. 3. Roof penetration: framing, flashing, repair Response: existing roof structures (2x12 joist 16" o.c.) are doubled to have opening for hood. And the metal fleshings are provided. See M1.0 and M1.1. Please feel free to ask me any issues on your review. Thank you. �i Young Kim, aia. CORRECTION M(O-05 RECEIVE JUL 12 2010 PERMIT CENTER June 16, 2010 • CI : ° of Tukwila Jim Haggerton, Mayor Department of Community Development Kai Wong PO Box 80563 Seattle, WA 98108 RE: Correction Letter #1 Mechanical Permit Application Number M10 -058 Javi's Mexi Mart —14816 Tukwila International BI Dear Mr. Wong, Jack Pace, Director This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johnson at 206 433 -7163 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File: M10-058 W:\Permit Center \Correction Letters\2010\M10 -058 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: June 16, 2010 Project Name: Javi's Mexi Mart Permit #: M10 -058 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Previous memo request for plans stamped and signed by the architect and /or engineer. The plans provided were for the structural portion. However the original hood plans have yet to be provided stamped and signed by the registered design professional in charge of those plans. Please provide those plans stamped and signed as requested. 2. The new plans and previous plans provided indicate the mechanical equipment on the roof located close to the roofs edge. Appliances, equipment, fans or other components that require service and roof hatch openings located within 10 -feet of a roof edge or open side, shall be provided with a guard a minimum of 42 inches high. Please provide clarification on the plans to show guards with details, or show equipment located where the exhaust shall meet the 10 -foot clearance to intake air and where the equipment is located such that a guard is not required and located more than 10 -feet from the roofs edge. (WIC 304.10) 3. Provide specific framing details for all new roof penetrations. Identify roof flashing and roof repairs. Specify hardware and fasteners as necessary. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. May 5, 2010 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Kai Wong PO Box 80563 Seattle, WA 98108 RE: Letter of Incomplete Application # 1 Mechanical Permit Application M10 -058 Javi's Maxi Mart —14816 Tukwila International Bl Dear Mr. Wong, Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 29, 2010 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the following comment. 1. Provide plans that are signed and stamped by the architect or engineer responsible for the drawings. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a "Revision Submittal Sheet" must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician Enclosures File: M10 -058 W:\Permit Center \Incomplete Letters\2010\M10 -058 Incomplete Ltr #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • PY W /ROUTING SLIP ACTIVITY NUMBER: M10 -058 DATE: 07 -12 -10 PROJECT NAME: JAVI'S MEXI MART SITE ADDRESS: 14816TUKWILA _INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Dr i sion Public Works Fire Prevention n Planning Division Structural Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07-13 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route y. Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 08 -10-10 Approved with Conditions cg. Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PER PY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -058 DATE: 06 -14 -10 PROJECT NAME: JAVI'S MEXI MART SITE ADDRESS: 14816 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # _ Revision # After Permit Issued DEPA THE TS: 6- 16-'0 h B I ding Division IP Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 06-15 -10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: xy Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-13 -10 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only r CORRECTION LETTER MAILED: l� — b _ Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PLAN 41 9ING SLIP ACTIVITY NUMBER: M10 -058 PROJECT NAME: JAVI'S MEXI MART SITE ADDRESS: 14816 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS 4'7 4{s4 uilding Division Public Works n Fire Prevention Structural Planning Division Permit Coordinator s DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: n Incomplete DUE DATE: 05 -04 -10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: `S''t0 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route n Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 06 -01 -10 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: htip : / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7 ' 2 ( 0 Plan Check/Permit Number: 1\1\ (0 — Q 527 ❑ Response to Incomplete Letter # Response to Correction Letter # 1 S L , , n e ((? , 1 ( 0 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: J 1q V 1 S M E)(M MAR-1— Project Address: 14-3 (a 'DA K 4 f LA ( 6 LV f7 Contact Person: N11 K1 6 Kim Phone Number: 10 6) 3 5 5 -41626 Summary of Revision: l) A- iZ.LH IT & Ci`i"" ' S S f 6, N AT ut 2) (Io (4-UA-4 -, 12-RiL /milt6 -Di✓b. (0' /}I�`7"1 0 C k 00 b) A - CH � E go* eb6G CMG -,ter exKMAS ��-X AN1D 1"144 -Ur t2.4 ' & ► : • L _ G r E ■ - II RECEIVED crry or rum, JUL 12 'ERmi CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of re is;' n Received at the City of Tukwila Permit Center by: 41._ Entered in Permits Plus on —7"-- H:\ApplicationsWomis- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 City of Tukwila REVISION UBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Web site: http://www.ci.tulcwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: o Plan Check/Permit Number: Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Vv to ! g Project Name: V16641. Pe. &f1 j T Al P. M iv-058 Project Address: 11- $ 1 (0 -1-IA 1G w i 1 ok (D+" t i 8' id Contact Person: Y0 U (Jb f-t r'( Phone Number: U6) '35 -9 6 8 & Summary of Revision: A rch1.e CA- v1 Y-C.9 ( N .- `f) r N'► 2c-h per-f- T.fpe. "(„ Hoof) permit _f?p REICEIVINI WV OF TUKWILA JUN 14 2010 PERMIT CENTER Sheet Number(s): A-1 12 1 1 , 'I 2 . Z "Cloud" or highlight all areas of revision including date of rev, Received at the City of Tukwila Permit Center by: l Entered in Permits Plus on (O`t 1— 0 H:\Applications'Forms- Applications On Line\2009 -08 Revision Submittal.doc Created: 8 -13 -2004 Contractors or Tradespeople Printer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MONARCH TRADING CORP UBI No. 600465574 Phone 2067636161 Status Active Address Po Box 80563 License No. MONARTC065Q1 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 11/21/1994 State WA Expiration Date 3/6/2011 Zip 98108 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date LEE, KING Cancel Date 01/01/1980 Bond Amount WONG, KAI 4 01/01/1980 LPM4078819 WOO, LILY Until Cancelled 01/01/1980 WONG, AMY /2009 01/01/1980 CBIC Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 COLONIAL AM CAS Et SURETY OF MARYLAND LPM4078819 08/12/2009 Until Cancelled $12,000.0007/20 /2009 3 CBIC SB0540 02/14/2002 Until Cancelled 08/12/2009 $12,000.0002/20 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 AMERICAN ECONOMY INS CO 02BP1636127 02/14/2010 02/14/2011 $1,000,000.0001 /22/2010 7 AMERICAN ECONOMY INS CO 02BP1636126 02/14/2009 02/14/2010 $1,000,000.00 02/19/2009 6 AMERICAN ECONOMY INS CO 02BP163612 02/14/2007 02/14/2009 $1,000,000.00 01/24/2008 5 AMERICAN ECONOMY INS CO 02BP163112 02/14/2005 02/14/2007 $1,000,000.0001 /25/2006 4 AMERICAN STATES INS CO 028P16316203 02/14/2004 02/14/2005 $1,000,000.0002 /12/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/15/2010 PROJECT AREA 000111•11 11111111111111111111 PROJECT AREA 10' -0" MINIMUM ) ANY AIR INTAKE EXIST. JST., TYP. 2x12 ATTACHED TO THE EXIST., TYP. SIMPSON "U210," TYP. (2) 2x12, TYP. SIMPSON "HUS212 -2," AT (2) JOISTS, TYP. MAKE —UP AIR FAN TYPE 1 EXHAUST 17x17 HOOD FIRE WRAP, TYP. TYPE I 1 E ONE —HOUR FIRE RATED PAD ON WOOD STUD WALL CONSTRUCTION MIN. 3' SPACING. TYP. (2) 2x12 JST, TYP. SCALE 1/4"= 4PECIAL INSPECTION FOR TYPE I GREASE HOOD TYPE I Grease hood ducts shall be special inspected b a third party special inspection agency. Inspections s all comply with 2006 IMC 506.3.3.1 Grease Duct T st, as required by Washington State Amendments. final report documenting required special inspections a d correction of any discrepancies noted in the i specions shall be submitted to the Building Official. �Q The final inspection report shall be prepared by the - a proved special inspection agency and shall be m ris bmitted to the Building Official prior to and as a ^-j c ndition of final inspection approval. 2006 IMC 507.2.1.1 OPERATION. Type I Hood systems shall be designed an installed to automatically activate the exhaust f whenever cooking operations occur. Thi activation of the exhaust fan shall occur thro an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. S0. 148TH ST. 508.1 MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided when ever the exhaust system is in operation. Makeup air intake opening locations shall comply with Sections 401.4 and 401.4.1. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical G lectrical I?rPlumbing Gas Piping City of Tukwila !! f;l�sg "'iNG DIVISION Plan Apprt the vi of aat FRAMING FOR HOOD SCALE 1 1/2 " =1,_Q" CODECOMP FOR COMPLIANCE APPROVED JUL 13 2010 / l v , Clty of Tukwila BUILDING DIVISION I? copy Permit o. el / r. eview appro is subject to errors and omissions. vat of coast ction documents does not authorize lation of an adopted code or ordinance. Receipt roved oved Field Copy and conditions is acknowledged: By Date: City Of B ILDING DIVISION /\ CORRECTION L1 R# PROJECT AREA REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. fl "tri Sion , will require a new plan submittal z�de additional plan review fees. RECEIVEC JUL 12 2010 PERMIT CENTER ROOF HOOD PLAN SCALE 1/4 " =1' -0" 212' -11 3/4" SITE PLAN SCALE 1"=30'-0" NO. REVISION DATE PROJECT TITLE /OWNER JAVI'S MEXI MARKET 14820 INT'L BLVD., TUKWILA, WA 98168 MR. CAMILO GUTIERRIEZ 206) 852 -9048 PERMIT SET NW ARCHITECTURE A R C H 1 T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 REGISTRATION 8171 REGISTERED w f ARRCCHITE YOUNG ' STATE�OF WASHINGTON NWA PROJECT NO. 301 -186 DRAWN BY — CHK BY YK DATE 6/14/10 SCALE AS NOTED TITLE SITE,ROOF,FRAM'G PLAN, SITE PLAN NUMBER M1.0 ALL COPY RIGHT RIGHTS RESERVED P. 10' MIN. TO ANY AIR INTAKE, AND PROPERTY LINE IN ANY DIRECTION; 10' MIN FROM SAME OR ADJACENT BUILDING. MAKE —UP AIR UNIT 10' MIN. FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE FLASHING EXHAUST FAN AIR VENT EXISTING BUILDING ROOF TRUSSES STRUCTURE NO CHANGE 16" 10.C., TYP. 17 "x17" OR EQUIVALENT -- 7 AREA, 24 GA. MIN. MAKE —UP x AIR DUCT , NON — COMBUSTIBLE SUSPENDED CEILING P. -H SEAL AROUND DUCT W/ 22 GA. STEEL FRESH AIR INTAKE FINISHED FLOOR 3 P. FILTERS -/ S.S. GREASE CUP 6 "MIN. HOOD SIDE ELEVATION SCALE 1 /2" = 1' -0" w L 0 0 cr LL 0 c-D w cD z z w c) 1 HR MIN. FIRE WRAP 17 "x17" OR EQUIVALENT AREA. 16 GA. GAL.. ALL WELDED EXHAUST DUCT HOOD WALL HANGER 3" AIR SPACE 1 HOUR RATED NON— COMBUSTIBLE WALL (EXIST.) 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES PARAPET WALL © ROOF EDGE, VERIFY IN FIELD. 10' MIN. TO ANY HAZARDOUS OR NOXIOUS CONTAMINATE SOURCE 1 10' MIN. TO ANY AIR INTAKE, AND PROPERTY LINE IN ANY DIRECTION; 10' MIN FROM SAME OR ADJACENT BUILDING. MAKE —UP AIR FAN EXHAUST FAN AIR INTAKE FILTER NON — COMBUSTIBLE FAN CURB (STEEL STUDS W/ 5/8" TYPE x DWG OUTSIDE) EXISTING BUILDING ROOF TRUSSES STRUCTURE NO CHANGE 1" MIN. 3" MAX AIR SPACE. TYP. 1 HR MIN. FIRE WRAP 20 "x 20" OR EQUIVALENT AREA, 24 GA. MIN. MAKE —UP AIR DUCT HOOD SHALL BE LISTED FOR USE OVER HEAVY DUTY COOKING APPLIANCES. 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES 17 "'x17 "" OR EQUIVALENT AREA. 16 GA. GALV. ALL WELDED EXHAUST DUCT SEAL DUCT 18" AROUND AT THE POINT OF PENETRATION W/ 22 GA. STEEL. TYP. —6" MIN. z (0 NON— COMBUSTIBLE SUSPENDED CEILING 0 UL LISTED 16' TYPE 1 EXHAUST HOOD 6 "MIN. (2) STOCK POT DEEP FRYER u U 15' -0" 24" BROILER (3) STOCK POT 0 6 "MIN. i 0 0 0 0 0 0 1' -6" MIN. NOTE: PROVIDE A MEANS TO AUTOMATICALLY START THE HOOD FAN AND MAKE —UP AIR UNIT FAN WHEN ANY COOKING APPLIANCE IS ENERGIZED. HOOD FRONT ELEVATION SCALE 1 /2" = 1' -0" NOTE: COOKING EQ. TO BE DETERMINED WHEN INSTALLATION. SHOWN ABOVE IS CONCEPTIONAL FOR REFERENCE A: XI 'L JST.,TYP. ST. JST., -1P. 2x8 BL<G. CLIP EA SI OF BLKG HA \GI \G AN W/ SIMPTSO\ Di, TYP. © EA T (. BY J ooD v 3/8 -16 ALL THR TYP 4 3/8 -16 -_AVY 0 \- ABOVE A\ A \G -R BRAC4 STA\LISS ST BRAC < T A35 MI\. 3/16" \FR.) AD ROD D,TY LOC< J 0 \= BELOW T, TYP L -L HA\CER S =CTIC UT 7 7 7 7 7 V ETAL ST., D WALL ADD'L JST.,TYP. EXIST. JST.,TYP. 2' -8 ". TYP. 888 2x8 BLKG. W/ SIMPTSON A35 CLIP EA SIDE, TYP. © EA END OF BLKG HANGING ANGLE (MIN. 3/16" THK. BY HOOD MNFR.) 3/8 -16 ALL THREAD ROD TYP 4 TYP. SECTION <'1 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET, TYP 4 STAINLESS STEEL HANGER BRACKET METAL STUD WALL HOOD 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES HOOD MOUNTING DETAIL SCALE NONE SECURE HOOD WALL ATTACHMENT BRACKETS TO METAL STUD © 24" INTERVAL USING SHEET METAL SCREWS 5/8" GWB UL LISTED SCREW IN COMPACT FLUORESCENT • BULB, TYP. H: 28 TO 30 • NOTE: (1) HOOD — ONE 8' -0" LONG TYPE 1 COMPENSATING S.S WALL CANOPY HOOD. UL LISTED ( #46AJ) AND NSF APPROVED MODEL # MIFD — 42. MIN. 20 GA. TYPE 304 OR TYPE 430 STAINLESS STEEL CONSTRUCTION WITH # 4 FINISH AT EXPOSED SURFACE; EXHAUST PLENUM: 16 GA. GALVANIZED STEEL ALL WELDED; FILTER BANK: SUPPLIED WITH UL. CLASSIFIED 20 x 20 x 2 REMOVABLE BAFFLE TYPE; GREASE RECEPTACLE: PROVIDE AT LEST ONE REMOVABLE GREASE RECEPTACLES. (2) EXHAUST DUCTS — 17"x17" OR EQUIVALENT AREA MIN., 16 GA. GALVANIZED STEEL ALL WELDED CONSTRUCTION. ONE HOOD OUTLET SHALL SERVE NOT MORE THAN A 18' -0 SECTION OF HOOD PER UL LISTED HOOD. (3) CONTINUOUS ENCLOSURE CONSTRUCTION - 3M FIRE BARRIER DUCT WRAP (ONE HR MIN. FIRE RATED UL, ICBO, ASTM TESTED AND LISTED PRODUCT) CONTINUOUS DUCT ENCLOSURE SHALL BE SEALED AROUND THE DUCT AT THE POINT OF PENETRATION AND VENTED TO THE EXTERIOR THROUGH A WEATHER PROTECTED OPENING. (4) EXHAUST FAN - DAYTON, GREASE TYPE KITCHEN EXHAUST BLOWER, 4HZ53, UP BLAST ROOF MOUNT. 3277 CFM1140 RPM, 115/230 V, 8/4 AMPS, 3/4 HP. NOISE: 14.8 SONES(A) (SEE ATTACHED MANUFACTORY DOCUMENT FOR DETAILED SPECIFICATIONS) (5) MAKE —UP FAN DAYTON 4TM06 ' BELT DRIVE BLOWER. SIDE DRAFT, 2958 CFM©0.0 SP, 1725 RPM, 115/230 V, 1 PH, 1/4 HP (SEE ATTACHED MANUFACTORY DOCUMENT FOR DETAILED SPECIFICATIONS) (6) EXHAUST FAN, MAKE —UP FAN AND GAS LINE TO BE ELECTRICALLY INTERLOCKED; (7) FIRE SUPPRESSION SYSTEM BY OTHERS SHOULD PROVIDE SEPARATE PLAN FOR APPROVAL. WORK WILL CONFORM TO UL 300, NFPA96, IBC06, IMC06, AND ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENT; (8) ALL DESIGN AND WORK WILL CONFORM TO IMC -06, UL 300, NFPA96, ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENT. HOOD EXHAUST & MAKE —UP AIR CALCULATIONS 4 BURNER TOP W/ OVEN RATE 0 0 0 0 1 1 (LF) 24" BROILER (3) STOCK POT 0 6 "MIN. i 0 0 0 0 0 0 1' -6" MIN. NOTE: PROVIDE A MEANS TO AUTOMATICALLY START THE HOOD FAN AND MAKE —UP AIR UNIT FAN WHEN ANY COOKING APPLIANCE IS ENERGIZED. HOOD FRONT ELEVATION SCALE 1 /2" = 1' -0" NOTE: COOKING EQ. TO BE DETERMINED WHEN INSTALLATION. SHOWN ABOVE IS CONCEPTIONAL FOR REFERENCE A: XI 'L JST.,TYP. ST. JST., -1P. 2x8 BL<G. CLIP EA SI OF BLKG HA \GI \G AN W/ SIMPTSO\ Di, TYP. © EA T (. BY J ooD v 3/8 -16 ALL THR TYP 4 3/8 -16 -_AVY 0 \- ABOVE A\ A \G -R BRAC4 STA\LISS ST BRAC < T A35 MI\. 3/16" \FR.) AD ROD D,TY LOC< J 0 \= BELOW T, TYP L -L HA\CER S =CTIC UT 7 7 7 7 7 V ETAL ST., D WALL ADD'L JST.,TYP. EXIST. JST.,TYP. 2' -8 ". TYP. 888 2x8 BLKG. W/ SIMPTSON A35 CLIP EA SIDE, TYP. © EA END OF BLKG HANGING ANGLE (MIN. 3/16" THK. BY HOOD MNFR.) 3/8 -16 ALL THREAD ROD TYP 4 TYP. SECTION <'1 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET, TYP 4 STAINLESS STEEL HANGER BRACKET METAL STUD WALL HOOD 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES HOOD MOUNTING DETAIL SCALE NONE SECURE HOOD WALL ATTACHMENT BRACKETS TO METAL STUD © 24" INTERVAL USING SHEET METAL SCREWS 5/8" GWB UL LISTED SCREW IN COMPACT FLUORESCENT • BULB, TYP. H: 28 TO 30 • NOTE: (1) HOOD — ONE 8' -0" LONG TYPE 1 COMPENSATING S.S WALL CANOPY HOOD. UL LISTED ( #46AJ) AND NSF APPROVED MODEL # MIFD — 42. MIN. 20 GA. TYPE 304 OR TYPE 430 STAINLESS STEEL CONSTRUCTION WITH # 4 FINISH AT EXPOSED SURFACE; EXHAUST PLENUM: 16 GA. GALVANIZED STEEL ALL WELDED; FILTER BANK: SUPPLIED WITH UL. CLASSIFIED 20 x 20 x 2 REMOVABLE BAFFLE TYPE; GREASE RECEPTACLE: PROVIDE AT LEST ONE REMOVABLE GREASE RECEPTACLES. (2) EXHAUST DUCTS — 17"x17" OR EQUIVALENT AREA MIN., 16 GA. GALVANIZED STEEL ALL WELDED CONSTRUCTION. ONE HOOD OUTLET SHALL SERVE NOT MORE THAN A 18' -0 SECTION OF HOOD PER UL LISTED HOOD. (3) CONTINUOUS ENCLOSURE CONSTRUCTION - 3M FIRE BARRIER DUCT WRAP (ONE HR MIN. FIRE RATED UL, ICBO, ASTM TESTED AND LISTED PRODUCT) CONTINUOUS DUCT ENCLOSURE SHALL BE SEALED AROUND THE DUCT AT THE POINT OF PENETRATION AND VENTED TO THE EXTERIOR THROUGH A WEATHER PROTECTED OPENING. (4) EXHAUST FAN - DAYTON, GREASE TYPE KITCHEN EXHAUST BLOWER, 4HZ53, UP BLAST ROOF MOUNT. 3277 CFM1140 RPM, 115/230 V, 8/4 AMPS, 3/4 HP. NOISE: 14.8 SONES(A) (SEE ATTACHED MANUFACTORY DOCUMENT FOR DETAILED SPECIFICATIONS) (5) MAKE —UP FAN DAYTON 4TM06 ' BELT DRIVE BLOWER. SIDE DRAFT, 2958 CFM©0.0 SP, 1725 RPM, 115/230 V, 1 PH, 1/4 HP (SEE ATTACHED MANUFACTORY DOCUMENT FOR DETAILED SPECIFICATIONS) (6) EXHAUST FAN, MAKE —UP FAN AND GAS LINE TO BE ELECTRICALLY INTERLOCKED; (7) FIRE SUPPRESSION SYSTEM BY OTHERS SHOULD PROVIDE SEPARATE PLAN FOR APPROVAL. WORK WILL CONFORM TO UL 300, NFPA96, IBC06, IMC06, AND ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENT; (8) ALL DESIGN AND WORK WILL CONFORM TO IMC -06, UL 300, NFPA96, ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENT. HOOD EXHAUST & MAKE —UP AIR CALCULATIONS AIR SPACE �. 42 ", 45 ", 48 ", 51" NOTE: 1. DUCT COLLAR CENTERED 2. CONSULT FACTORY FOR 3. COLLAR SIZE BASED ON L 18' -0" MAX. LENGTH ON "L" DIMENSION. ALTERNATE COLLAR LOCATIONS. 1600 TPM. 3" AIR SPACE Z SEE CHART FOR MIN. "W" OR OVERHANGE INSTALLATION & OPERATING INSTRUCTIONS SCALE 1/2" = 1' -0" 3° EXHAUST DUCT ONE LAYER FIRE MASTER FAST WRAP 1.5" THICK OR EQUIVALENT 3" MIN. OVER LAY. TYP. STEEL BANDING 1/2" WIDE MIN. OR PINNING. TYP. FIRE WRAP MATERIAL: PRODUCT: 3M FIRE BARRIER DUCT WRAP 15A. IS NON — ASBESTOS CONTAIN A SAFER FIBER CONSTRUCTION AND CONSISTING OF A PATENTED INORGANIC BLANKET ENCAPSULATED WITH A SCRIM — REINFORCED FOIL. SPECIALLY USED TO FIRE RATE COMMERCIAL KITCHEN GREASE DUCT AND IS A PROVEN ALTERNATIVE TO 1 OR 2 HOUR FIRE RESISTANT RATED SHAFT ENCLOSURES. PERFORMANCE: 3M FIRE BARRIER DUCT WRAP 15A HAS BEEN TESTED IN ACCORDANCE WITH THE STANDARDS OF ASTM C 411, ASTM C 518, ASTM E 84, ASTM E 119, ASTM E 136, ASTM E 814, UL 1978 (SECTIONS 12 & 13) AND UL 910. SEE ATTACHED PRODUCT DATA SHEET FOR OTHER SPECIFICATIONS AND DETAIL. 3/8 -16 ALL THREAD ROD CONNECTED TO ROOF JOIST BY OTHERS. 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET BY OTHERS. STAINLESS STEEL HANGER BRACKET NOTE: 1. TREADED ROD AND LOCK NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR. 2. HANGER BRACKET IS PRE — PUNCHED AT FACT STANDARD FEATURES — UL LISTED #46AJ — NSF APPROVED #D031638 — CONFORMS TO NFPA STANDARD #96 — SQUARE BOX DESIGN — 3" AIR SPACE AT REAR — TYPE 304 STAINLESS STELL WHERE EXPOSED WITH #4 FINISH — FACTORY INSTALLED DUCT COLLAR — UL LISTED GREASE TYPE BAFFLE FILTERS — REMOVABLE GREASE COLLECTORE — PRE —WIRED VAPOR —PROOF LIGHTS — SUPPORT BRACKETS TYP. FIRE WRAP OVERLAY DETAIL SCALE 1/2" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 3 2010 City of Tukwila BUILDING DIVIgION RECEIVED JUL 12 2010 PERMIT CENTER INSTALLATION: THE EXHAUST AND SUPPLY AIR FLOW RATE WERE ESTABLISHED UNDER CONTROLLED LABORATORY CONDITIONS: — UL LISTED EXHAUST AIRFLOW RATE AT 400 CFM /FT OF CAPTURE AREA LENGTH. — UL LISTED A HOOD OUTLET SHALL SERVE NOT MORE THAN A 18 —FOOT SECTION OF HOOD. — GREATER EXHAUST AND /OR LESSER SUPPLY AIR IS REQUIRED FOR COMPLETE VAPOR AND SMOKE REMOVAL IN SPECIFIC INSTALLATION. 6" MINIMUM OVERHANG FROM OPEN SIDES AND FRONT SIDE OF HOOD. — THE EXHAUST AND MAKE —UP AIR SYSTEMS SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH. — LIGHTING: ONE 120VAC MAX. 12 AMPS HOOD RATE REQUIRED (LF) (CFM /LF) HOOD CFM DUCT SIZE DUCT AREA FPM EXHAUST 15' 400 6,000 17 "x17 "/144 2.01 SF 2,985 MAKE —UP 90% OF EXHAUST 5,400 17 "x17 "/144 2.01 SF 2,687 AIR SPACE �. 42 ", 45 ", 48 ", 51" NOTE: 1. DUCT COLLAR CENTERED 2. CONSULT FACTORY FOR 3. COLLAR SIZE BASED ON L 18' -0" MAX. LENGTH ON "L" DIMENSION. ALTERNATE COLLAR LOCATIONS. 1600 TPM. 3" AIR SPACE Z SEE CHART FOR MIN. "W" OR OVERHANGE INSTALLATION & OPERATING INSTRUCTIONS SCALE 1/2" = 1' -0" 3° EXHAUST DUCT ONE LAYER FIRE MASTER FAST WRAP 1.5" THICK OR EQUIVALENT 3" MIN. OVER LAY. TYP. STEEL BANDING 1/2" WIDE MIN. OR PINNING. TYP. FIRE WRAP MATERIAL: PRODUCT: 3M FIRE BARRIER DUCT WRAP 15A. IS NON — ASBESTOS CONTAIN A SAFER FIBER CONSTRUCTION AND CONSISTING OF A PATENTED INORGANIC BLANKET ENCAPSULATED WITH A SCRIM — REINFORCED FOIL. SPECIALLY USED TO FIRE RATE COMMERCIAL KITCHEN GREASE DUCT AND IS A PROVEN ALTERNATIVE TO 1 OR 2 HOUR FIRE RESISTANT RATED SHAFT ENCLOSURES. PERFORMANCE: 3M FIRE BARRIER DUCT WRAP 15A HAS BEEN TESTED IN ACCORDANCE WITH THE STANDARDS OF ASTM C 411, ASTM C 518, ASTM E 84, ASTM E 119, ASTM E 136, ASTM E 814, UL 1978 (SECTIONS 12 & 13) AND UL 910. SEE ATTACHED PRODUCT DATA SHEET FOR OTHER SPECIFICATIONS AND DETAIL. 3/8 -16 ALL THREAD ROD CONNECTED TO ROOF JOIST BY OTHERS. 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET BY OTHERS. STAINLESS STEEL HANGER BRACKET NOTE: 1. TREADED ROD AND LOCK NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR. 2. HANGER BRACKET IS PRE — PUNCHED AT FACT STANDARD FEATURES — UL LISTED #46AJ — NSF APPROVED #D031638 — CONFORMS TO NFPA STANDARD #96 — SQUARE BOX DESIGN — 3" AIR SPACE AT REAR — TYPE 304 STAINLESS STELL WHERE EXPOSED WITH #4 FINISH — FACTORY INSTALLED DUCT COLLAR — UL LISTED GREASE TYPE BAFFLE FILTERS — REMOVABLE GREASE COLLECTORE — PRE —WIRED VAPOR —PROOF LIGHTS — SUPPORT BRACKETS TYP. FIRE WRAP OVERLAY DETAIL SCALE 1/2" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 3 2010 City of Tukwila BUILDING DIVIgION RECEIVED JUL 12 2010 PERMIT CENTER INSTALLATION: THE EXHAUST AND SUPPLY AIR FLOW RATE WERE ESTABLISHED UNDER CONTROLLED LABORATORY CONDITIONS: — UL LISTED EXHAUST AIRFLOW RATE AT 400 CFM /FT OF CAPTURE AREA LENGTH. — UL LISTED A HOOD OUTLET SHALL SERVE NOT MORE THAN A 18 —FOOT SECTION OF HOOD. — GREATER EXHAUST AND /OR LESSER SUPPLY AIR IS REQUIRED FOR COMPLETE VAPOR AND SMOKE REMOVAL IN SPECIFIC INSTALLATION. 6" MINIMUM OVERHANG FROM OPEN SIDES AND FRONT SIDE OF HOOD. — THE EXHAUST AND MAKE —UP AIR SYSTEMS SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH. — LIGHTING: ONE 120VAC MAX. 12 AMPS NO. REVISION DATE PROJECT TITLE /OWNER JAVI'S MEXI MARKET 14820 INT'L BLVD., TUKWILA, WA 98168 MR. CAMILO GUTIERRIEZ 206) 852 -9048 PERMIT SET Rq 1 s•rexet Ate► o I n WA 2 n i (loo 1 -7,9.10 - NWA PROJECT NO. 301 -186 1 SHEET DRAWN BY — CHK BY YK DATE 07/05/10 SCALE AS NOTED TITLE PROJECT INFO., MAP, NOTES, DTLS NUMBER !11.1 AIL COPY RIGHT RIGHTS RESERVED — PROPERTY LINE r - -J SOUTH 148th STREET PROPERTY LINE — i GENERAL CONSTRUCTION NOTES 1. The General Contractor shall provide roof penetrations and roofing for installation of required ductwork. 2. The General Contractor shall be responsible for maintaining structural integrity and provide required structural supports as required by the International Building and Mechanical Codes. The General Contractor shall be responsible for other trades unless otherwise stated by the conditions of the general contract with the project owner. TYPE I EXHAUST SYSTEM NOTES The exhaust and make -up air systems are to meet requirements of the International Mechanical Code and NFPA -96. 2 Exhaust hood and ductwork must be located a minimum of 18" from any combustible material Exhaust must be a minimum of 10' -0" from any air intake, adjacent building, or adjoining property lines. 3. Exhaust and make -up air systems must be electrically interconnected to be operated simultaneously by a single on/off switch. 4. Any Type I exhaust system shall have a fire suppression system. THE MATERIAL AND INSTALLATION HAS BEEN LISTED BY UL —G18, ICC— ES— ESR2213, UL —C -AJ -7119 2006 IAPMO /UMC AND COMPLIES WITH ASTM E -2336 �nF•n,c..n.cn... .....Y a.r a.Y.a a. 0 INSULATION CROSS - SECTION INSULATION ISOMETRIC DETAIL 2 HOUR FIRE RATED DUCT WRAP 00 JOHN MANSVILLE, THERMAL CERAMIC, OF 3M — 1.5" DUCT INSULATION, TWO LAYERS. O FILAMENT TAPE (TEMPORARY HOLD) Q STEEL BANDS AND CLIPS (PERMANENT HOLD) ® 3 —INCH OVERLAPS (2ND LAYER ALL JOINTS) 5:: BUTT —JOINT (1ST LAYER ONLY) © STEEL INSULATION PINS 70 1-1/2" SQ. OR 1-1/2" DIA. STEEL SPEED CLIPS Not to Scale EXHAUST AND MAKE -UP AIR FANS LOCATED ON ROOF PLAN VIEW / Lttu 41.83' Lu cL 'if I 111.49' 146.56' _• NEW EXHAUST FAN 42.19' _ •°'®.® 76.44'\�..� .` • • PROPERTY LINE PROPERTY LINE • 212.98' • • _.M • -_ .INNE. -._• SITE PLAN Scale 1" = 30' -0" MAKE -UP AIR FAN 18" TYPE I EXHAUST HOOD L TYPEI EXHAUST FAN 10' -0" MINIMUM TO ANY AIR INTAKE • ONE -HOUR FIRE RATED PAD ON WOOD STUD WALL CONSTRUCTION Scale 1/4" =1' -0" 18" REVIEWED FOR CODE COMPLIANCE APPKUWED JUL 1 3 201 City of Tukwila BUILDING DIVIRInr 1 RECEIVED APR 2 9 2010 PERMIT CENTER PARCEL NO. 0042000142 VICINITY PLAN Not to Scale ZONED PROPERTY ADDRESS 14816 TUKWILA INTERNATIONAL BLVD PROPERTY OWNER DOUG STEINBERG 26519 CAMBRIDGE DRIVE KENT, WA 98032 SHEET INDEX SHEET 1 VICINITY MAP 1 SITE PLAN AND FLOOR PLAN VIEW SHEET 2 ELEVATION AND SECTION, MUTUAL CAPTIVE AIRE HOOD AND FAN INFORMATION, AND SYSTEM WEIGHTS tM O NARC H TRADING CORP 948 S. DORIS ST. SEATTLE, WA 9131 08 206- 763 -6161 Contractors Lic. MONARTC065Q 1 OCCUPANT JAVI'S MEXI MART 14820 Tukwila International Blvd Tukwila, WA 98168 DATE April 8, 2010 CONTRACTOR KAI WONG SHEET 1 of 2 HANGING ANGLE 3" STANDOFF EXHAUST RISER r /6" U.L. CLASSIFIED / L BAFFLE -TYPE GREASE FILTERS 100W VAPORPROOF INCANDESCENT LIGHT - 2.75" GREASE DRAIN WITH REMOVABLE CUP 54' EQUIPMENT BY OTHERS 16" 6 ( 24" NOM 33" MIN 48" MAX 78" -1'P, SUPPLY RISER WITH VOLUME DAMPER 23.5% OPEN STAINLESS STEEL PERFORATED PANEL SECTION VIEW - MODEL 5424 -ND -2 with PSP Accessorru 70.0000 3.00 00 . 54.0000 16.0000 HOOD INFORMATION HOOD N0. MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CONFIG. WEIGHT TOTAL EXH. CFM RISER(S) TOTAL SUP. CFM RISER(S) END TO END ROW WIDTH LENG. DIA. CFM S.P. WIDTH LENG. DIA. CFM S.P. 1 5424 ND -2 -PSP -F 15 -0'00 450 Deg. 4500 10" 39" 1 4500 -1.142 4050 12" 28" 384 1350 0.195" 430-SS EXPOSED ALONE ALONE 682 LBS. Field cu In ZA U.L. Listed rnrnndnmM LIOnt O O 12" 28" 14. WRITTEN HOOD. DIMENSIONS HAVE PRECEDENCE OVER SCALE. 15. SIGNED BAND 'APPROVED' COPIES OF THIS DOCUMENT FACTORY PRIOR TO COMMENCEMENT OF FABRICATION. 1350 0.195" 12" 28" 1350 0.195" 12.0000 IIc 3 8.0000 U.L. Listed Screw In Compact Fluorescent Bulb Reid Cut 10•X39' Exhaust Riser NOTE: Additional hanging angles provided for hoods longer than 12 ft. 30.0000 28. 000 - 60.0000 12.0000 28.1000 15' 0.00 "Nom. /15' 0.00 "00 60.0000 8,01108 11 0 28. 000 30.0000 PLAN VIEW - Hood #1 15' 0.00" LONG 5424ND -2 -PSP -F FAN #1 NCA18FA - EXHAUST FAN 38 718 33 318 2 18 21 24 28 29112 FEATURES: If ® ® ® - NORTHWEST REGIONAL OFFICE 2804 GRAND AVE. SUITE 303 EVERETT, WA. 98201 PH: (888 )-338 -5225 FAX: (425 )-212 -5998 EMAIL: reg85 @captiveaire.com s www.captiveaire.com FAN 42 A2-G15 - SUPPLY FAN 1. UNTEMPERED SUPPLY UNIT WITH 10" BLOWER IN SIZE #1 HOUSING 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. EXTRA SET OF V- BELTS. ONLY TO BE ORDERED AS FAN OPTION AT TIME FAN IS ORDERED. 5. MOTORIZED BACK DRAFT DAMPER 24" X 24 ", STANDARD GALVANIZED CONSTRUCTION, 11/4" REAR FLANGE, WITH H- 2000A18 MOTOR, WALL SUPPLY MOUNT, FOR SIZE 2 UNTEMPERED FAN HOUSING BLOWER DISCHARGE - \ CURB -- \ 18 314" 6118" - ROOF MOUNTED FANS - RESTAURANT MODEL - UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300 °F (149 °C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300 °F (149 °C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600 °F (316 °C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. TYPE I EXHAUST FAN 26-8" CLEAN-OUT ACCESS AT EACH DUCTWORK CHANGE OF DIRECTION 40" MINIMUM 18" 10' -0" MINIMUM MAKE -UP AIR FAN TWO HOUR FIRE RATED DUCT WRAP STAINLESS STEEL ONE HOUR FIRE RATED PAD ON WOOD STUD WALL CONSTRUCTI ❑N 4' -3° 41 -3" 6" MIN 22/22 18" 15/32 24" COOKLINE EQUIPMENT W 6' -6" 10' -0" SECTION Scale 3/8" =1' -0 EXHAUST AIR DUCTWORK TWO (2) COLLARS TO PANTLEG DUCT 14" X 14" @ 2250 CFM =1655 FPM VELOCITY TO MAIN VERTICAL DUCT 20" X 20" @ 4500 CFM =1619 FPM VELOCITY FULLY WELDED 16 GAUGE STEEL (SEE CALCULATIONS BELOW) DUCTWORK TO BE CONTINUOUS INTERNAL OR EXTERNAL LIQUID -TIGHT WELDED SMOOTH, ACCESSIBLE FOR INSPECTION, AND WITHOUT GREASE TRAPS MAKE -UP AIR DUCTWORK 22" X 22" @ 4050 CFM =1205 FPM VELOCITY TRANSITIONS TO HORIZONTAL DUCT 15" X 32" @ 4050 CFM = 1216 FPM VELOCITY TRANSITION TO THREE (3) VERTICAL 10" X 28" EACH @ 1350 CFM = 696 FPM VELOCITY FULLY SEALED 22 GAUGE STEEL (SEE CALCULATIONS BELOW) TYPE I 1::? EXHAUST FAN 40" - MINIMUM 18" TWO HOUR FIRE RATED DUCT WRAP 4 20/20 LIFTING LUG 37318" 3 3/4" EQUIPMENT CURB 20" 31" ROOF OPENING 2' SMALLER THEN CURB DIMENSION. EXHAUST FAN INFORMATION 36114" --.16" FLEX CONDUIT FOR FIELD WIRING 31" 90 3/4" FAN 40118" THE CAPTIVE AIRE MODEL HAS & SND2 AS BEEN E.T.L. TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 228 CFM PER LINEAR FOOT OVER 400 DEGREE COOKING` EQUIPMENT AIRFLOW DIA. ALL THREAD ROD 1/2• TO ROOF JOIST ONE ANOTHER HANGING HANGING 1 -1,2„ 1u% k +-- SERVICE DISCONNECT �® SWITCH BLOWERIMOTOR ACCESS DOOR 24" SERVICE " CLEARANCE REQ. 31" 90 3/4" FAN THE CAPTIVE AIRE MODEL HAS & SND2 AS BEEN E.T.L. TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 228 CFM PER LINEAR FOOT OVER 400 DEGREE COOKING` EQUIPMENT +/2• CONNECTED THROUGH ANOLE '`-.1 1 -112' DIA. ALL THREAD ROD 1/2• TO ROOF JOIST ONE ANOTHER HANGING HANGING 1 -1,2„ 1u% k DIA HEAVY DUTY NUT ABOVE AND ONE BELOW ANGLE STEE ""DWG ANGLE *ROD AND NUTS TO BE SUPPLIED BY INSTALLMO CONTRACTOR RANGING ANGLE IS PRE- PUNCHED AT FACTORY CAPTIVE -AIRE HOODS HAVE OPTIONAL CLEARANCE UNIT N0. FAN UNIT MODEL# MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT(LBS.) 1 NCA18FA NCA18FA A2 -G15 4500 - 1.125 1078 2.000 1 230 12.5 191 MUA FAN INFORMATION FAN THE CAPTIVE AIRE MODEL HAS & SND2 AS BEEN E.T.L. TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 228 CFM PER LINEAR FOOT OVER 400 DEGREE COOKING` EQUIPMENT +/2• CONNECTED THROUGH ANOLE '`-.1 1 -112' DIA. ALL THREAD ROD 1/2• TO ROOF JOIST ONE ANOTHER HANGING HANGING 1 -1,2„ 1u% k DIA HEAVY DUTY NUT ABOVE AND ONE BELOW ANGLE STEE ""DWG ANGLE *ROD AND NUTS TO BE SUPPLIED BY INSTALLMO CONTRACTOR RANGING ANGLE IS PRE- PUNCHED AT FACTORY CAPTIVE -AIRE HOODS HAVE OPTIONAL CLEARANCE HANGING ANGLE DETAIL UNIT N0. FANUNITMODEL# BLOWER HOUSING TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) 2 A2 -G15 G15 A2 4050 0.750 688 2.000 1 230 12.5 384 CLEAN-OUT ACCESS AT EACH DUCTWORK CHANGE OF DIRECTI ❑N TYPICAL CAPTIVE AIRE VENTILATED EQUIPMENT CURB WITH BOLT ON HINGE ASSEMBLY TO EXHAUST FAN BASE CONFIGURATION MAY VARY TO ACCOMMODATE PROJECT CONDITIONS SLOPE DUCT TYPE I EXHAUST HOOD 11 mom L J STAINLESS STEEL ONE HOUR FIRE RATED PAD ON WOOD STUD WALL CONSTRUCTION ®a ® ® ®O® ®O® COG ® ®o® mom STOCK POT RANGE NORTH ELEVATION 48' 2 OPEN GRILL BURNERS STOCK STOCK POT PDT RANGE RANGE 11 18" Scale 3/8" =1' -0" 2250 EXH CFM _ (14" X 14" DUCT = 196 SQIN =144 =) 1.36 SQFT = 1655 FPM VELOCITY 4500 EXH CFM - (20" X 20" DUCT = 400 SQIN =144 =) 2.78 SQFT =1619 FPM VELOCITY 90% MAKE -UP AIR TO EXHAUST AIR 4050 MUA CFM (22" X 22" DUCT = 484 SQIN =144 =) 3.36 SQFT =1205 FPM VELOCITY 4050 MUA CFM _ (15" X 32" DUCT = 480 SQIN _ 144 =) 3.33 SQFT =1216 FPM VELOCITY 1350 MUA CFM - (10" X 28" DUCT = 280 SQIN - 144 =) 1.94 SQFT = 696 FPM VELOCITY FAN BASE IMC 506.5.3 PROVIDE FLEXIBLE CONDUIT CONNECTION FOR ELECTRICAL HOOK -UP OF THE EXHAUST FANS TO ALLOW MOVEMENT OF THE HINGED FAN ASSEMBLIES FOR CLEANING OF THE SYSTEM DUCTWORK IMC 507.2.1.1 TYPE I HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES, BY MEAN OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS. REVIEWED FOR CODE COMPLIANCE AP ME JUL 1 3 20111 City of Tukwila BUILDING D1VIRICN ETL LISTING DESCRIPTION BLOCK THE CAPTIVE AIRE MODEL HAS & SND2 AS BEEN E.T.L. TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 228 CFM PER LINEAR FOOT OVER 400 DEGREE COOKING` EQUIPMENT +/2• CONNECTED THROUGH ANOLE '`-.1 1 -112' DIA. ALL THREAD ROD 1/2• TO ROOF JOIST ONE ANOTHER HANGING HANGING 1 -1,2„ 1u% k DIA HEAVY DUTY NUT ABOVE AND ONE BELOW ANGLE STEE ""DWG ANGLE *ROD AND NUTS TO BE SUPPLIED BY INSTALLMO CONTRACTOR RANGING ANGLE IS PRE- PUNCHED AT FACTORY CAPTIVE -AIRE HOODS HAVE OPTIONAL CLEARANCE HANGING ANGLE DETAIL REDUCTION SYSTEMS AVAILABLE AS FOLLOWS; ,MAIE$1AL CLEARANCE REDUCTION SYSTEM NON - COMBUSTIBLE NONE REQUIRED UMrFED- COMBUSTIBLE 3• UNINSULATED STANDOFF COMBUSTIBLE 3• UNINSULATED STANDOFF I/2• CONNECTED THROUGH ANGLE *ROD HANGING DIA ALL THREAD ROD 1/2• DIA TO ROOF JOIST ONE ABOVE ANOTHER HANGING HANGING HEAVY DUTY NUT AND ONE BELOW MGM CLEARANCE TO COMBUSTIBLES AND NUTS TO BE SUPPUED ANGLE IS PRE - INSTALLATION 1. ALL ELECTRICAL "FIELD" CONNECTIONS AND RELATED INTERCONNECTIONS BY ELECTRICAL CONTRACTORS. 2. ALL PLUMBING .FIELD' CONNECTIONS AND RELATED INTERCONNECTIONS BY PLUMBING CONTRACTORS. 3. HANGING BRACKETS LOCATED AND WELDED AS SHOWN ON PLANS. ALL OTHER HANGER MATERIALS PROVIDED BY INSTALLING CONTRACTORS. 4. ALL CONNECTIONS FROM CAPTIVE -AIRE DUCT PER MECHANICAL CONTRACTORS'S PLANS. 5. COOKING EQUIPMENT TO SHUTOFF IN EVENT OF FIRE. 6. EXHAUST FANS TO TURN ON IN EVENT OF FIRE. 7. ALL LIGHTS FIXTURE SHOWN INSTALLED BY CAPTIVE -AIRE ARE FACTORY PREWIRED. INTERCONNECTIONS BETWEEN HOODS AND TO SWITCHES BY ELECTRICAL CONTRACTORS. 8. LAMPS FOR UGHT FIXTURES BY INSTALUNG CONTRACTORS. 9, SEISMIC RESTRAINTS ARE RESPONSIBILITY OF INSTALUNG CONTRACTOR. 10. INSTALLING CONTRACTORS ASSUME ALL RELATED RESPONSIBILITY FOR VERIFICATION OF DIMENSIONAL DATA CONTAINED ON THESE DOCUMENTS FOR ACCURACY, INTEGRATION, AND ADMINISTRATION OF CODE REQUIREMENTS IN EFFECT PRIOR TO ANY RELEASE FOR PRODUCTION OF EQUIPMENT SHOWN. BALANCE BY INSTALUNG CONTRACTOR PUNCHED AT FACTORY ND-2 HANGING ANGLE DETAIL ND2 HANGING ANGLE LOCATIONS L 1 4.% 4.16 -1 ® ■V Field cu In ZA U.L. Listed rnrnndnmM LIOnt O O 11. KITCHEN HOODS MUST BE BALANCED WITH KITCHEN. 12. KITCHEN SHALL BE NEGATIVE WITH RESPECT TO DINING AREA. 13. RESTAURANT SHALL BE POSITIVE WITH RESPECT TO AMBIENT PRESSURE. II, 14. WRITTEN HOOD. DIMENSIONS HAVE PRECEDENCE OVER SCALE. 15. SIGNED BAND 'APPROVED' COPIES OF THIS DOCUMENT FACTORY PRIOR TO COMMENCEMENT OF FABRICATION. GENERAL NOTES 2.25" --I L -1 L -225" EXHAUST CFM - LENGTH OF HOOD X CFM/UNFT. (LOAD) SUPPLY CFM - EXHAUST CFM X PERCENTAGE REQUIRED CF1A Aewf•ti w�e+e+L n�netir .0011:141 1011:11113011 IOOL� TOTAL DUCT AREA -144 X FPM(*) TOTAL DUCT AREA ��� ��� DUCT LENGTH - DUCT DEPTH . *CAPTIVE -AIRE VENTILATOR DUCT SIZES ARE CALCULATED USING AN EXHAUST OF 1500 -1800 FPM AND A SUPPLY VELOCITY OF t00D FPM. 5 lEJ CALCULATIONS UTILIZED CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH: 2.75 2.75 1- _J 5.00 1 -1 5.ao • NFPA #96 • I.C.B.O. 4416 • NSF • SBCCI PST & ESI NO. 93+37 • B.O.CA. 193 -16 • ETL LISTED FILE, 3054804 -001 PSP HANGING ANGLE LOCATIONS UL LISTED LIGHT DETAIL �, \STFO NS F® NFPA UL # L55 -2004 C.S.A. # L55- 2004 -CSA ETL RATINGS (PER UL 710): FILE # 3054804 -001 MAX. TEMP. MIN. EXH. CFM /FT MAX. '.. MUA. CFM /FT LENGTH RANGE MAX. LEN. FOR 1 RISER WIDTH RANGE WIDTH INCR. SIDE OVERHANG FRONT OVERHANG VERT. CLEARANCE (WITH LIGHTS) VERT. CLEARANCE (W/O LIGHTS) MODEL: SND & SND2 (WITH & W/O PSP) 400 DEG. 226 CFM /FT - 3' -16' 16' 30" -76' 1" 6' 6- 38"47 - 600 DEG. 294 CFMIFT - 3' -16' 18' 39" -76' 1" 6' 6" 36•-4r - APPROVED FILTER TYPES: ALUM. BAFFLE, SS BAFFLE, HE SS BAFFLE, CAPTRATE (2 STAGE), AND HV CARTRIDGE PERFORMANCE: SND & SND2 (WITH & W/O PSP) MAX. AVG. COOKING SURFACE TEMPERATURE (DEG. F) I COOKING SURFACES CONFIGURATION MIN. EXHAUST CFMIFT SUGGESTED SUPPLY CFWFT. VIA FRONT SUPPLY PLENUM 450 DEG.-OVENS, STEAMERS, WALL HOOD 226 160 KETTLES, OPEN - BURNER RANGES GRIDDLES, AND FRYERS 2 PIECE ISLAND BACK TO BACK WALL HOODS 458 320 600 DEG.-GAS CHARBROILERS WALL HOOD 294 205 ELECTRIC CHARBROILERS, AND WOKS 2 PIECE ISLAND BACK TO BACK WALL HOODS 568 410 "SUPPLY CFM /FT CONSULT FACTORY REPRESENTATIVE IF HIGHER VALUES ARE REQUIRED RECEIVED APR 2 9 2010 PERMIT CENTER EXHAUST SYSTEM WEIGHTS TYPE I EXHAUST HOOD TYPE I EXHAUST DUCTWORK TYPE I EXHAUST FAN MAKE -UP AIR DUCTWORK MAKE -UP AIR FAN = 682 LBS. = 273 LBS. = 191 LBS. = 165 LBS. = 384 LBS. TOTAL = 1,695 LBS. THE SHOWN WEIGHT INCLUDE AN ESTIMATE OF ACCESSORY COMPONENT WEIGHTS SUCH AS HANGING HARDWARE, AND EXHAUST DUCT FIRE RATED INSULATION MIOOS8 (MONARCH TRADING CORP 948 S. DORIS ST. SEATTLE, WA 991 ❑8 206- 763 -6161 Contractors Lic. MONARTC065Q1 OCCUPANT JAVI'S MEXI MART 14820 Tukwila International Blvd Tukwila, WA 98168 DATE April 8, 2010 CONTRACTOR KAI WONG SHEET 2 of 2