Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M10-063 - WESTFIELD SOUTHCENTER MALL - VERIZON WIRELESS
VERIZON WIRELESS 132 SOUTHCENTER PY M10 -063 Parcel No.: Address: City (*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT 9202470010 132 SOUTHCENTER MALL TUKW Project Name: VERIZON WIRELESS Permit Number: M10 -063 Issue Date: 05/24/2010 Permit Expires On: 11/20/2010 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 TOM S WINGARD Phone: 253 318 -1949 2306 PACIFIC AV , TACOMA WA 98402 Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98134 Contractor License No: MCKINCL942DW Phone: 206 762 -23311 Expiration Date: 03/16/2012 DESCRIPTION OF WORK: REPLACE LIKE FOR LIKE SPLIT SYSTEM, 10 -TON HEAT PUMP Value of Mechanical: $19,641.00 Type of Fire Protection: SPRINKLER/AFA Permit Center Authorized Signature: Fees Collected: $424.06 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. rr � Signature: �"vr� T Y�.n/� C�i,. Date:. )/ �: / /C' Print Name: �' .� W This permit shall become null and void if the work s not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -063 Printed: 05 -24 -2010 wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us Parcel No.: 9202470010 Address: Suite No: Tenant: 132 SOUTHCENTER MALL TUKW VERIZON WIRELESS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10-063 ISSUED 05/12/2010 05/24/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturers installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Cond -10/06 M10-063 Printed: 05 -24 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * *continued on next page ** does not imply approval of Fire Prevention Bureau at doc: Cond -10/06 M10 -063 Printed: 05 -24 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http. //www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: / e'j rfiki Date: / ?5f? ordinances governing or local laws regulating doc: Cond -10/06 M10 -063 Printed: 05 -24 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. 0.1%V.9 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: "t`vL-' —t-I '1)1 (� Suite Number: 132 Floor: 1 Site Address: 833 South Center Tenant Name: Verizon Wireless, Westfield Mall New Tenant: ❑ Yes I..No Property Owners Name: Mailing Address: City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Tom S Wingard Day Telephone: (253) 318 -1949 Mailing Address: 2306 Pacific Ave Tacoma WA 98402 Zip E -Mail Address: tomw @mckinstry.com City State Fax Number: (253) 272 -1714 MECHANICAL CONTRACTOR INFORMATION Company Name: McKinstry Co. Mailing Address: 2306 Pacific Ave Tacoma WA 98402 Contact Person: Tom S Wingard E -Mail Address: tomes @mckinstry.com Contractor Registration Number: MCKINCL942DW City Day Telephone: Fax Number: Expiration Date: State (253) 318 -1949 (253) 272 -1714 06/16/2010 Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: Fax Number: City State Zip Day Telephone: H:\Applications\Fonns- Applications On Line\2009 Applications \1.2009 - Mechanical Permit Application.doc Revised: 1-2009 bh Page 1 of 2 Valuation of Project (contractor's bid price): $ 19,641 Scope of Work (please provide detailed information): Replace like for like split system 10 ton heat pump Use: Residential: New Commercial: New Replacement Replacement Fuel Type: Electric m Gas ❑ Other: Heat Pump Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: �_2 Signature: srs, Print Name: Mailing Address: Y c` C )c 5cr Date:'/ 7 / /0 Day Telephone: • .3 /8 ?? % l3G'C:e1-1 (22 OA. cfs City State Zip Date Application Accepted: c - it 11/9 Date Application Expires: 2—I b Staff Initials: _ H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh ge2of2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: M10 -063 Address: 132 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/12/2010 Applicant: VERIZON WIRELESS Issue Date: Receipt No.: R10 -00918 Initials: WER User ID: 1655 Payment Amount: $339.25 Payment Date: 05/24/2010 03:50 PM Balance: $0.00 Payee: MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1212 339.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 339.25 Total: $339.25 P!4 'sY , E RECEIVi:. P doc: Receiot -06 Printed: 05 -24 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: M10-063 Address: 132 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/12/2010 Applicant: VERIZON WIRELESS Issue Date: Receipt No.: R10 -00825 Initials: JEM User ID: 1165 Payment Amount: $84.81 Payment Date: 05/12/2010 04:31 PM Balance: $339.25 Payee: MCKINSTRY CO. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1205 84.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 84.81 Total: $84.81 PAYMENT RECEIVED doc: Receiot -06 Printed: 05 -12 -2010 INSPECTION RECORD etain a copy with permit INSPEN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Mod -0623 %ea: ... 1/4. li :?D0.tiitj.e6js T of Inspection: ype ' iu" F 1- 04- ; Address: Sc_ MA-Li- I A 7 Date Called: .... Special Special Instructions: . -76 def. 3 I P 3 - oi 4 g • . ciAli - 0%6 " . II Q ‘, A at■ Date Wantedor;•- „....to Requester: _. Re . ...., ., rr . .. • Phone No: I 3.01FA--o-49. 0RJAppro'Ved per applicable codes. COMMENTS: : 0 Corrections required prior to approval. •• •:•• An/ 65 001144 )41p4 • R SPECTION FEE REQUI D. Prior to jxt inspection, fee must be p d at 6300 Southcenter Blv . Suite MO. all to schedule reinspection. • INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1) -063 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION %-g' 6300 Southcenter Blvd., #1,00, Tukwila, WA 98188 (206)431 -3670 Project: Ve') -. (,t) .teJ s sTY ., � Inspection: j „l..6i . - eJ I- N € I e-1-- To " -r „ F , ,.. ►e Address: -v_ s G !vk A I' I� Date Called: Special Instructions: 04/1W —10 "f._ Date Wanted: 7- �/ �� ' �v a.r�r, P.m. Requester: Phone No. Approved per applicable codes. 14Corrections required prior to approval. . COMMENTS: 0 ADO) S v io K P 5 IiteI 3aA/a1 - 06vvet ive 44 (A) ; I 1,1 I- N € I e-1-- To " -r „ F , ,.. ►e 144.0 ak cIllr (Zak/ Inspec �: $60. REINS Date: 7 7 -4 El PECTION FE L REQUIRE [1! Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. Receipt No.: Date: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit MO- 04.3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: l ,er;2. (w¢s i; •e I4 "1rPiI!) Type of Inspection: Are Arm: .. Address: / 3 7.. Sibodr+c6 - 41) .Suite #: Contact Person: Pre-Fire: Special Instructions: Phone No.: o6- 83 2/Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: 144_c iA w4!-4.40(raire i t c; s,r �1 Needs Shift Inspection: Sprinklers: Are Arm: .. Hood & Duct: Monitor: . Pre-Fire: Permits: Occu:pamcy Type: Inspector:: ICM 591 Date: Hrs.: ' $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. / Word /Inspection Record Form.Doc 1/13/06 • T.F.D. Form F.P. 113 „I niv Do•Ta atu:jM115:A9 2uJT .513 [sz w FILE COPY Permit No. . 1b° O(.3 Plan review approval is subject to errors and omissions. !. pproval of construction documents does not authorize v olation of any adopted code or ordinance. Receipt r approved Field Copy and conditions is acknowledged: By ” /.� -�-� 5.7 Date:: V> z/ /d City Of Tukwila BUILDING DIVISION REVISIONS No chances shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal �and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑.,echanical I Iectrical [plumbing 61Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAY 19 2010 btit Cify of Tukwila BUILDING niVISION MEWED emro - MAY 12 2010 PERMIT CENTEP REVIEWED FOR CODE COMPLIANCE APPRWED M/HI 1 y 2010 City of Tukwila BUILDING DIVISION C%TY oF Tu Kwu MAY 12 2010 PERMIT A/1 10 -0(6 FILE COPY t Permit No. TWA120SQ207.03 All dimensions are in inches TOP DISCHARGE AREA SHOULD BE VERTICALLY UNRESTRICTED FOR 100" MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN -OFF WATER DOES NOT POUR DIRECTLY ON UNIT. 1 3/4" DIAMETER HOLE (HIGH VOLTAGE) I 1/4- DIAMETER UFTING HOLE (4 PLACES) 7/8" DIAMETER (CONTROL WIRING) 2- DIAMETER EXTRUDED HOLE 51 1/4" 10 Ton Split System Cooling Single Compressor TWA120A 38 3/4- CONTROL ACCESS COMPRESSOR TAPS ACCE MINIMUM CLEARANCE FOR PROPER OPERATION IS 36- FROM WALLS, SHRUBBERY, PRIVACY FENCES. ETC. MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72'. 7/8" DIAMETER EXTRUDED HOLE 7/16" DIA. (ISOLATOR MOUNTING HOLES (4 PLACES) Service Access #1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 9 2010 City l' BUILDING BUILDING DIVIRION #2 #4 #3 44 7/ 3 7/8' Table 1 Unit Wiring 25 3/4 30" RECOMMENDED SERVICE CLEARANCE FOOTPRINT (BOLT DOWN PATTERN) Unit Minimum Circuit Maximum Fuse Size or Unit Operating Ampacity Maximum Circuit Breaker' Canada Only Model No. Voltage Range Circuit Breaker „OTWA120A3 187 -253 53.8 80 100 TWA120A4 414 -506 25.6 40 40 TWA120AW 518 -632 20.4 30 30 Note: 1. HACR type circuit breaker per NEC. Table 2 Unit and Corner Weights (Ibs) Shipping Net Corner Weights Maximum Maximum 1 2 3 4 496 442 150 121 71 88 Table 3 Accessory Weights (Ibs) Accessory Net Rubber -In -Shear Isolators 2 Steel Spring Isolators 12 Anti -Short Cycle Timer 1 Coil Guard 11 Low Ambient 23 Thermostat 1 Table 4 General Data 10 Ton Single Compressor TWA120A3, A4,AW Cooling Performance' Gross Cooling Capacity Matched Air Handler 121,000 Heat Pump Only' 126,000 ARI Net Cooling Capacity' 117,000 EER` Matched Air Handler 8.9 Heat Pump Only 10.2 Integrated Part Load Value' - System KW /Condensing Unit KW 13.15/12.30 Heating Performance' ARI Heating with Matched Air Handler High Temperature Capacity System Kw /COP Low Temperature Capacity System Kw /COP 119,000 11.70/3.0 64,000 8.96/2.1 Compressor No./Type 1/Trane H No. Speeds 1 No. Motors /Hp 1/10 Motor RPM 3450 Sound Rating (BELS)' 8.8 System Data' No. Refrigerant Circuits 1 Suction Line (in.) OD 1 3/8 Liquid Line (in.) OD Outdoor.Coll = Type Tube Face Area (sq ft) ' •. Rows /FPI• ' • Refrigerant Control .` Plate Fin .375 24.0 2/18 Expansion Valve Outdoor Fan -Type No. Used /Diameter (in.) Drive Type/No. Speeds CFM No. Motors /HP Motor RPM j eke Table 5 Gross Cooling Cpacities (MBH) Heat Pump Only Outdoor Suction Temperature Degrees F Temperature In Degrees F 30 35 40 45 50 55 Head Pressure PSIG 174.0 181.0 188.0 195.0 203.0 212.0 65 Capacity BTUH /1000 117.0 129.0 141.0 154.0 167.0 181.0 Unit KW 9.27 9.66 10.0 10.4 10.8 11.1 Head Pressure PSIG 199.0 206.0 214.0 222.0 230.0 239.0 75 Capacity BTUH /1000 110.0 121.0 132.0 145.0 157.0 170.0 Unit KW 9.76 10.2 10.7 11.1 11.5 12.0 Head Pressure PSIG 227.0 234.0 242.0 250.0 259.0 269.0 85 Capacity BTUH /1000 102.0 113.0 124.0 135.0 147.0 159.0 Unit KW 10.2 10.7 11.2 11.7 12.3 12.8 Head Pressure PSIG 256.0 264.0 272.0 281.0 291.0 300.0 95 Capacity BTUH /1000 94.4 104.0 115.0 126.0 137.0 148.0 Unit KW 10.7 11.2 11.8 12.3 12.9 13.5 Head Pressure PSIG 288.0 296.0 305.0 314.0 324.0 335.0 105 Capacity BTUH /1000 86.6 95.9 106.0 116.0 126.0 137.0 Unit KW 10.9 11.6 12.2 12.9 13.6 14.3 Head Pressure PSIG 115 Capacity BTUH /1000 Unit KW 323.0 331.0 340.0 350.0 360.0 371.0 78.8 87.4 96.4 106.0 115.0 125.0 11.2 11.9 12.6 13.4 14.2 15.0 Performance data calculated at 15 F subcooling and 20% superheat and does not include capacity loss due to refrigerant lines. Propeller 1/28 Direct/1 Table 6 Capacity Curves Heat Pump Only 8120 1/1.00 1,100 Refrigerant Charge (Field Supplied) t(Lbs of 'R ?22)r 't 23.75 ,NOTES: • 1. Cooling Perfohitance Is rated at 95:F ambient, 80 °F entering dry bulb, 67 °F entering wet bulb. Gross capacity does not Include the effect of fan motor heat. ARI capacity is net and Includes the effect of fan motor heat. Rated in accordance with ARI Standard 240. 2. Condensing Unit Only Gross Cooling Capacity rated at 45 °F saturated suction temperature and at 95 °F ambient. 3. ARI Nel Cooling Capacity Is calculated with matched blower coil and 25 n. of 1 318', '''/" OD Interconnecting tubing. 4. EER Is rated at ARI conditions and in accordance with DOE test procedures. 5. Integrated Part Load Value Is based on ARI Standard 240. Units are rated at 80 °F ambient, 80'F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm. 6. Sound is rated In accordance with ARI Standard 270. 7. System Data based on maximum linear length 80 ft. Maximum Ilft: suction 60 ft., liquid 60 ft. For greater lengths, refer to refrigerant piping applications manual. 8. Refrigerant (operating) charge Is for condensing unit (all circuits) with matching blower coils and 25 fl. of interconnecting refrigerant lines. All units are shipped with a small holding charge only. 205 190 >- - 175 Um av 160 4 4U; 145 OZO 130 30a. I-OD 115 � Q 100 OW 0 85 70 55 25 30 35 40 45 50 2 SUCTION TEMPERATURE (F) 55 60 OUTDOOR AIR ENTERING CONDENSER (F) u Table 7 Electrical Characteristics - Motors - 60 Cycle Unit Model No. TWA120A3 TWA120A4 TWA120AW Compressor Motor No. Volts Phase Amps RLA(ea) LRA(ea) Condenser Fan Motor Amps No. Volts Phase FLA(ea) LRA(ea) 1 208 -230 3 1 460 3 1 575 3 38.2 224.0 1 208 -230 1 6.0 18.3 98.0 1 460 1 2.7 14.7 78.0 1 575 1 2.0 17.5 7.0 5.7 Table 8 Gross Cooling Capacities (MBH) 10 Ton TWA120A Heat Pump with 10 Ton TWE120AAir Handler Enter. Dry 85 AmbientTemperature 95 105 Entering Wet Bulb 115 CFM Airflow Bulb ('F) 61 67 73 61 67 73 61 67 73 61 67 73 MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC 75 113.0 87.5 126.1 67 4 135 3 46.0 106.7 84.9 119 1 64 8 127.8 43.4 99.9 82.2 111 6 62.1 119 7 40 7 93 1 79.5 104 0 59.4 111 6 38 0 80 113.0 103.6 126.1 83.5 135.3 62.1 106 7 101.0 119 1 80.9 127.8 59.7 99.9 98 3 111 6 78.2 119.7 56.8 95.6 95 6' 104.0 75.5 111.6 54.1 3600 85 118.6 118 6' 126.1 99 6 135 3 78 2 114.3 114.3' 119 1 97 0 127 8 75 8 107.9 107 9' 111 6 94.3 119 7 73.1 99.5 99.5' 104 0 91.6 111.6 70.4 90 121.8 121.8' 126.1 115 6 135.3 94.3 114.9 114 9' 119 1 113.2 127 8 91.8 109.8 109.8' 111 6 110 3 119 7 89.2 106 4 106 4' 107.6 107.6' 111.6 86 5 75 114.8 91 6 128.2 70.5 137 5 48.2 108.4 88 9 121 0 67.8 129 9 45.5 101.5 86.1 113.4 65 0 121.6 42.7 94.6 83.3 105.7 62.2 113.4 39.8 80 114 8 108.5 128.2 87 4 1375 65.1 108 4 105 8 121 0 84 7 129 9 62.5 102 9 102.9' 113.4 81 9 121.6 59.5 100.1 100.1' 105.7 79.0 113 4 58.7 4000 85 124 2 124.2' 128 2 104.2 137.5 81 9 119 7 119 7' 121 0 101.6 129 9 79.3 113 0 113 0' 113 4 98.7 121.6 76.5 104 2 104.2' 105.7 95 9 113 4 73.7 90 1275 127.5'1282 121.1 137.5 988 1203 120 3' 121 0 118.5 129.9 96.1 1150 1150'11551155'1216 934 111.4 1114'112.71127'113.4 905 75 116 7 95.8 130 2 73 7 139.7 50.4 110.2 92 9 123 0 70 9 131 9 47.5 103 1 90 0 115.2 67 9 123.6 44.6 96 1 87 0 107 4 65 0 115.2 41.6 80 116 7 113 4 130 2 91 3 139 7 68 0 110.5 110.5' 123.0 88.5 131.9 65.3 107 6 107 6' 115.2 85 5 123.6 62.2 104.6 104.6' 107 4 82 8 115 2 59.2 4400 85 129 8 129 8' 130 2 108 9 139 7 85.6 122.4 122.4' 123.0 106 2 131.9 82.9 114 8 114 8' 115.2 103 1 123.6 80.0 107.0 107.0' 107 4 100 2 115.2 77.0 90 129.4 129.4' 130.2 126 5 139.7 103.2 123 1 123 1' 123 8 123 8' 131.9 100 5 120.2 120.2' 120.7 120.7' 123.6 97.6 113.2 113 2' 114.9 114 9' 115 2 94 6 75 118.5 99.9 132.3 76.9 141.9 52.5 111 9 96.9 124 9 73 9 134.0 49 6 104 8 93.8 117.1 70.9 125.5 46.5 97.6 90 8 109 1 67.8 117.1 43 4 80 118.5 118.2 132.3 95.3 141.9 70.9 115.3 115 3' 124 9 92 3 134.0 68 1 112 2 112 2' 117.1 89.2 125.5 64.9 103.2 103.2' 109 1 86.1 117 1 61 8 4800 85 131.4 131.4' 132 3 113 6 141.9 89.3 124.0 124 0' 124 9 110 7 134 0 86 5 116 4 116 4' 117 1 107 6 125.5 83 4 108.9 108.9' 109 1 104 5 117.1 80.3 90 131.8 131 8' 132 3 132 0 141 9 107.6 128 4 128.4' 129.1 129 1' 134 0 104 8 125 4 125.4' 125.9 125.9' 125.5 101.8 115 4 115 4' 116 7 116 7' 117.1 98 7 NOTES: 1. Dry Coil Condition. Total gross capacity (MBh) shown to the left is not applicable. In this case the Sensible Heat Capacity (SHC) Is the total capacity. All temperatures are in degrees F. All capacities shown are gross and have not considered Indoor fan heat. To obtain net cooling capacities subtract indoor fan heat. MBH = Total Gross Cooling Capacity SHC = Sensible Heat Capacity Table 9 Gross Heating Capacities (MBH) 10 Ton TWA120A Heat Pump with 10 Ton TWE120A Air Handler At 4000 CFM Outdoor Heating Capacity (BTUH /1000) At Temperature Indicated Indoor Dry Bulb Temperature In Degrees F 60 70 75 Total Power in Kilowatts At Indicated Indoor Dry Bulb Temperature 80 60 70 75 80 -18 -13 -8 -3 2 7 12 17 22 27 32 37 42 47 52 57 62 67 72 31 9 36.7 41 4 46.2 51 0 55.8 60.6 65.3 72 1 78.9 85.7 95 2 109.0 123.0 132.0 142.0 151.0 161 0 170.0 31 2 35.9 406 45.3 49 9 54.6 59.3 64 0 70 6 77.2 83.9 93.2 107.0 119.0 129.0 139.0 148.0 157.0 167.0 30 9 35 5 40 1 44.8 49 4 54.0 58.7 63 3 69 9 76.4 83.0 92.2 105.0 118.0 128.0 137.0 146.0 156.0 165.0 305 35 1 39 7 44.3 48.9 53.4 58.1 62 7 69.1 75.6 82.1 91 2 104.0 117.0 127.0 136.0 145.0 154.0 163.0 6 65 6 92 720 7.47 7.75 8.02 8.30 8 57 8 87 9.17 9.48 9 92 10.60 11.20 11.70 12.10 12.60 13.00 13.40 6.90 7.19 7 48 7.77 8 07 8.36 8.65 8.94 9.26 9.58 9.89 10 40 11.00 11.70 12.20 12.70 13,10 13 60 14.10 7.03 7.33 7 63 7.93 8.23 8.53 8.83 9.13 9.45 9.78 10.10 10 60 11.30 12.00 12.50 12.90 13.40 13 90 14.40 7.15 7 46 7 77 8.08 8.39 8.69 9.00 9.31 9.64 9.98 10.30 10.80 11.50 12.20 12.70 13.20 13.70 14 20 14.70 Correction Factors - Other Airflows (Table Value X Correction Factor = Value at New Airflow) Airflow 3500 4500 Heating Capacity x .99 x 1.01 Compressor Kw x 1.02 x 0.98 Values at ARI Rating Conditions of: 70 and 47/43 (High Temp. Point) 70 and 17/15 (Low Temp. Point) Airflow = 4000 cfm 3 Heating Capacity (High Temp.). 120000 Btuh Heating Capacity (Low Temp.) = 64000 Btuh Compressor Power (High Temp.). 9600 Watts Compressor Power (Low Tamp.) = 6870 Watts Coati. of Perf. (High Temp). 3.00 Coaff. of Ped. (Low Temp) = 2.10 Outdoor Fan Power = 950 Watts Indoor Fan Power = 1120 Watts NOTE: 1. Rated with 25 feet of 1' /e suction and '' /:' liquid line. General Units shall be assembled on heavy gauge steel mounting /lifting rails and shall be weather proofed. Unit shall include a hermetic reciprocating compressor, plate fin condenser coil, fan and motor, controls, and holding charge of nitrogen. Operating range shall be between 115 °F and 35 °F in cooling as standard from factory. Units shall be UL 1995 listed CSA CAN/ CSA22.2 No. 236 -M90, certified and rated in accordance with ARI Stan- dard 210/240, 340 and 270. Casing Unit casing shall be constructed of 18 gauge zinc coated heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized and finished with a weather - resistant baked enamel finish. Units surface shall be tested 500 hours in salt spray test. Units shall have removable end panels which allow access to all major components and controls. Refrigeration System - Single Compressor Units shall have a single refrigeration circuit. Each refrigeration circuit has an integral subcooling circuit. A refrigeration filter drier shall be provided as standard. The TWA120A units shall have both a liquid line and suction gas line service valve with gauge port. Units shall have one direct -drive hermetic reciprocating compressor with centrifugal oil pump providing positive lubrication to moving parts. Motor shall be suction gas - cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Crankcase heater, temperature and current- sensitive Since The Trane Company has a policy of continuous product Improvement, it reserves the right to change design and specification without notice. Technical Literature Printed in USA The Trane Company 2701 Wilma Rudolph Blvd. Clarksville, TN 37040 http://www.trane.corn ©American Standard Inc. 1996 Mechanical Specifications motor overloads shall be included for maximum protection. Shall have internal spring isolation and sound muffling to minimize vibration trans- mission and noise. compressor slugging by temporarily interrupting compressor operation when low evaporator coil temperatures are encountered. Condenser Coil Coils shall be internally finned or smooth bore 3/8" copper tubes mechanically bonded to configured aluminum plate fin as standard. Coil shall be factory pressure and leak tested to 425 psig air pressure. Metal grilles with PVC coating for coil protection is optional. Condenser Fan And Motor Direct - drive, statically and dynamically balanced 28 inch propeller fan with aluminum blades and electro- coated steel hubs shall be used in draw - through vertical discharge position. Either permanently lubricated totally enclosed or open construction motors shall be provided and shall have built in current and thermal overload protection. Motor(s) shall have be either ball or sleeve bearing type. Controls Heat pump units shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Control wiring shall be 24 -volt control circuit which includes fusing and control transformer. Units shall provide external location for mounting a fused disconnect device. Defrost Controls Electronic timed intiated, temperature terminated defrost system with choice of 50, 70 or 90 minute cycle. Timed override limits defrost cycle to 10 minutes. Low Ambient Operation Standard units shall start and operate to approximately 35 °F when matched with Trane air handlers and coils. Optional head pressure control accessory permits operation to 0 °F. ACCESSORIES Low Ambient Head Pressure Control — Shall modulate the RPM of unit outdoor fan motor in response to outdoor ambient temperature and unit head pressure. Accessory provides unit cooling operation to outdoor temperatures of 0 F. Vibration Isolation Packages — Shall reduce transmission of noise and vibration to building structures, equipment and adjacent spaces. Packages shall be available in either neoprene -in -shear or spring -flex types. Anti - Short-Cycle Timer — Shall prevent rapid on -off compressor cycling in light load conditions by not allowing compressor to operate for 5 -7 minutes upon shutdown. Shall consist of a solid state timing device, 24 -volt, 60 cycle with either 5 or 7 minute fixed -off timing period. Condenser Coil Guard — Metal grille with PVC coating shall be provided to alleviate coil damage. Library Product Section Product Literature Unitary Product Model Literature Type Sequence Date Split System Heat Pump TWA120A — 10 Ton Submittal 207.03 November 1991 File No. Supersedes 4 PL -U N- S /S- TWA120 -SQ- 207.03 11/91 TWA120 -SQ- 207.02 • FILE COPY Darn It No. Tag: All dimensions are in inches. NOTES 1. LENGTH. 11001. 1010 HEIGHT OPRN510N5 00 NOT RRCLLIDE I/2' AC055 PANEL OEPTL 2. RE110VABLE IRAN PAN AND ATTACHED DRAIN C@OIECO00 NAT BE INSTALLED TM E11NER END OF UNIT N EITHER 7140 VERTCA, OR HORIZONTAL COIOI.IRAGON. PLASTIC DRAN PAN ACCESS RATE ON NE END GE UNIT 0PP09TE DRAIN CONNECD4 N MUST BE REMOVED TO 5110E DRAIN PAN OuT OF LINT FOR CLEATING. ACCESS PLAIT MUST BE RE- INSTALLED AFTER SLIDING DRAIN PAN BACK INTO LINT. 3. IF PERIODIC DRAIN PAN CLEANING I5 RE0UNE0, ALLON ROOM FOR PARTIAL RE00VAL OF PAN C• GRAN CONNECTION END OF LINT. Air Handler Dimensions (in.) TWE120SQ202.12 SUBMITTAL 10 Ton Single Circuit Convertible Air Handler TWE120A REVIEWED FOR CODE COMPLIANCE APPROVED MAY 19 2010 City of Tukwila BUILDING DIVISION A B 54 63 -1/2 C D E 25 19-3/4 22 -3/8 F G H J 22 — 17 -3/4 4 K Q S 45-1/4 38 -1/8 1/2 V W Y AA 15 1 -3/8 2 Table 1 Unit Wiring Unit Unit Operating Model No. Voltage Range TWE120A1 187 -253 TWE120A3' 187 -253 TWE120A32 414 -506 TWE120AW 518 -632 Note: 1. When wired for 208 -230 volt. 2. When wired for 460 volt. 3. HACR type circuit breaker per NEC. Minimum Circuit Ampacity 11 8 5 4 Maximum Fuse Size or Maximum Circuit Breaker' 15 15 15 15 Table 2 Unit and Corner Weights (Ibs)' Net Corner Weights - Vertical Maximum (Ibs) #1 #2 #3 #4 430 107 107 107 107 Shipping Maximum (Ibs) 473 Note: 1. If application requires steam or hot water heating coils, field supplied isolators must be utilized. RECEIVED CITY OF TUIKWIIA MAY 122010 °EnhA''t CENTER Comer Weights - Horizontal A BC D 101 114 113 102 AtOWS 22.23MM OIA' (4) KNOCKOUTS FOR HORIZONTAL SUSPENSION 266.7■M C Or K.O. (TW) 36 7/8' FILTER ACCESS PANEL ACCESS PANEL 2 . 57 3/4" RETURN AIR OPENING VERTICAL - HORIZONTAL RETURN OR HORIZONTAL - VERTICAL RETURN RETURN AIR OPENING Q 57 3/4" RETURN AIR OPENING VERTICAL - VERTICAL RETURN OR HORIZONTAL - HORIZONTAL RETURN J 6 7/8" 16 1/4" 4. %sue ••0 -+"q IIKKAw • ... Table 3 General Data ti 4. ". 10 Ton Single Circuit TWE120A1 TWE120A3',AW 31.75 MM System Data No. Refrigerant Circuits 1 1 Suction Line (in.) OD 1 3/8 1 3/8 Liquid Line (in.) OD 1/2 1/2 6 5/8^ Indoor Coil — Type Plate Fin Plate Fin Tube Size (in.) 0.0. .375 .375 Face Area (sq fl) 11.2 11.2 Rows /FPI 3/12 3112 Refrigerant Control Expansion Valve Expansion Valve Drain Connection Size (in.) 1PVC 1 PVC Indoor Fan — Type Centrifugal Centrifugal No. Used 1 1 Diameter x Width (in.) 15 x 15 15 x 15 Drive Type /No. Speeds BelUAdjustable Belt/Adjustable CFM 4000 4000 No. Motors /HP 1 1 Motor RPM Standard /Oversized 2.002 2.00/3.00 Motor RPM 1725 1725 Motor Frame Size 56HZ 56HZ Fillers Type /Furnished (No.) Size Recommended Throwaway/Yes Throwaway/Yes (4)16x25x1 (4)16x25x1 ARI tested and certified with various condensing units per ARI Standard 210/ 240 or 340/360 certification program. Note: 1. Ships wired for 208 - 230/3/80. Field convdertible to 460/3/60. 2. TWE120A1 does not have an oversized motor option. #1 C #2 #4 VERTICAL #3 I I L — — -J Air Flow Horizontal ) 4 l 1 MON n HORIZONTAL Q HORIZONTAL (HORIZONTAL- RETURN) (VERTICAL- RETURN) D UV VERTICAL VERTICAL (VERTICAL- RETURN) (HORIZONTAL- RETURN) 2 Table 4 Electrical Characteristics — Motors -60 Cycle Standard Evaporator Fan Motor Oversized Evaporator Fan Motor Unit Amps Amps Model No. No. Volts Phase RLA LRA No. Volts Phase FLA LRA TWE120A1 1 208 -230 1 8.3 57.4 — — — — — TWE120A3' 1 208 - 230/460 3 6.0/3.4 49.0/27.5 1 208 - 230/460 3 9.4/4.6 74.9/39.3 TWE120AW 1 575 3 2.6 17.5 1 575 3 5.4 37.3 Note: 1. Ships wired for 200 - 230/3/60. Field convertible to 480/3/80. Table 5 Standard Motor Sheave /Fan Speed (RPM) Sheave Position Unit 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Model No. Open Open Open Open Open Closed TWE120A1 TWE120A3,AW2 710 761 812 863 913 964 Notes: 1. Factory setting is 3.0 turns open. 2. Factory setting is 4.5 turns open. Table 6 Unit Wiring With Electric Heat (Single Point Connection) — 10 Ton Air Handlers Maximum Fuse Heater Heater To Use Unit Control Minimum orHACRCircuit Model No. KW Rating' With Unit Power Supply Stages Circuit Ampacity2 Breaker Size. BAYHTRL106A 4.33/5.76 1 31/41 40/45 BAYHTRL112A 8.65/11.52 TWE120A1 208-230/1/60 1 63/733 70/80 BAYHTRL117A 12.98/17.28 1 89/101 90/110 BAYHTRL123A 17.30/23.04 2 115/1313 125/150 BAYHTRL129A 21.65/28.80 2 141/1613 150/175 BAYHTRL305A 3.75/5.00 BAYHTRL310A 7.45/9.96 TWE120A3 BAYHTRL315A 11.25/14.96 BAYHTRL325A 18.71/24.92 BAYHTRL335A 26.20/34.88 208 - 230/3/60 1 21/23 25/25 1 34/38 35/40 1 47/53 50/60 2 73/833 80/90 2 98/1134 100/125 BAYHTRL405A 5.00 BAYHTRL410A 9.96 TWE120A35 BAYHTRL415A 14.96 BAYHTRL425A 24.92 BAYHTRL435A 34.88 460/3/60 1 12 15 1 20 20 1 27 30 2 42 45 2 57 60 BAYHTRLWO5A 5.00 BAYHTRLWIOA 9.96 TWE120AW BAYHTRLW15A 14.96 BAYHTRLW25A 24.92 BAYHTRLW35A 34.88 575/3/60 1 10 15 1 16 20 1 22 25 2 35 35 2 47 50 NOTES: 1. KW ratings are at: 208/240V for 208-230V air handlers 480V for 460V air handlers 600V for 575V air handlers For other than rated volta voltage, aci Voltage 2 g p ty- Rated Voltage xRatedCapacity. 2. Any power supply and circuits must be wired and protected in accordance with local codes. 3. Field wire must be rated at least 75 C. 4. Field wire must be rated at least 90 C. 5. With motor field converted to 460V. 6. The HACR circuit breaker is for U.S.A. installations only. 3 Table 7 Evaporator Fan Performance - TWE120A1 External Static Pressure (Inches of Water Gauge) 10" .20" .30" .40" .50" .60" .70" .80" .90" 1.00" 1.20" 1.40" 1.60" CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3200 3400 3600 3800 4000 4200 4400 4600 4800 2 HP Standard Motor d Field Supplied Low Static Drive' 2 HP Standard Motor d Sheaves - - 570 .67 603 .75 636 .83 670 .91 703 1.00 736 1.08 756 1.14 784 1.20 838 1.32 890 1.49 942 1.66 - - 1 560 .71 592 .79 623 .88 652 .95 685 1.04 716 1.12 743 1.18 762 1.24 790 1.30 844 1.43 895 1.59 948 1.80 557 .77 583 .84 613 .92 643 1.01 667 1.07 700 1.16 730 1.23 750 1.27 768 1.34 797 1.41 850 1.55 900 1.69 954 1.94 579 0.94 605 1.01 634 1.09 663 1.18 683 1.24 710 1.29 738 1.37 762 1.42 785 1.49 813 1.56 861 1.72 911 1.87 - - 602 1,11 628 1.17 656 1.26 683 1.35 698 1.40 720 1.43 747 1.50 773 1.58 801 1.64 829 1.71 872 1.89 922 2.04 - - 626 1.23 651 1.31 677 1.40 703 1.481 714 1.53 741 1.59 765 1.66 790 1.72 815 1.81 841 1.90 888 2.08 - - - - 649 1.36 674 1.45 698 1.531723 1.62 729 1.65 761 1.76 784 1.81 807 1.87 830 1.98 852 2.09 669 1.52 692 1.621 714 1.69 735 1.77 747 1.82 782 1.92 798 1.99 815 2.06 689 1.69 711 1.79 729 1.85 746 1.92 764 1.98 802 2.09 NOTE: 1. Field supplied Vow static drive (see Table 7A) Data includes pressure drop due to wet coil and 1" filter. Fan motor heat (M Bh) = 3.15 X BHP. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown In ourtabulardata will notresult in nuisance tripping or premature motor failure. Our product's warranty will not be affected. Table 7A Field Supplied Low Static Fan Drive'TWE120A1 Motor Sheave Nominal Turns Open RPM 0 745 1 706 2 666 3 627 4 588 5 549 Note: 1. Field supplied components required: Blower sheave: Fixed Pitch (8.8 inch Pitch Diameter), 1.0 inch Bore, Single Groove, "A" Belt. Belt: A54 4 Table 8 Evaporator Fan Performance TWE120A3, AW External Static Pressure (Inches of Water Gauge) .10" .20" .30" .40" .50" .60" .70" .80" .90" 1.00' 1.20" CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM RPM RPM RPM 2 HP Standard Motor & Field Supplied Low Static Drive 2 HP Standard Motor & Sheaves 3200 - - 570 .67 603 .75 636 .83 670 .91 703 1.00 736 1.08 756 1.14 784 1.20 838 1.32 3400 - - 56(1-7771 592 .79 623 .88 652 95 685 1.04 716 112 743 118 762 1.24 790 130 844 143 3600 557 77 583 .84 613 92 643 101 667 1.07 700 1.16 730 123 750 1.27 768 1.34 797 1.41 850 1.55 3800 579 94 605 101 634 109 663 118 683 1.24 710 1.29 738 137 762 1.42 785 1.49 813 1.56 861 1.72 4000 602 1.11 628 1.17 656 1.26 683 1.36 698 1.40 720 1.43 747 1.50 773 1.58 801 1.64 829 1.71 872 1.89 4200 626 1.23 651 131 677 1.40 703 148 1714 153 741 1.59 765 1.66 790 1.72 815 181 841 190 888 2.08 4400 649 1.36 674 1.45 698 1.531 723 1.62 729 1.65 761 1.76 784 1.81 807 1.87 830 1.98 852 2.09 1904 2.27 4700 669 1.52 792 1.62 1 714 1.69 735 1.77 747 1.82 782 1.92 798 1.99 815 2.06 1 837 2.18 862 2.29 922 2.45 4800 689 1 69 711 1 79 729 1 85 746 1 92 764 1 98 802 2 09 812 2 17 822 2 24 844 2.39 872 2.48 939 2.64 3 HP Oversized Motor and Sheaves NOTE: 1. Field supplied low staticdrtve (see Table 28-2). Data includes pressure drop due to wet coil and 1" filter Fan motorheat(MBh)= 3.15X BHP. Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously atall cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data Minot result in nuisance topping or premature motor failure. Our product's warranty will not be affected. Table 8 (Continued) Evaporator Fan Performance TWE120A3,AW External Static Pressure (Inches of Water Gauge) 1.40" 1.60" 1.80" 2.00" 2.20" 2.40" CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2 HP Standard Motor & Sheaves 3 HP Oversized Motor & Sheaves 3200 890 1.49 942 1.66 1001 1.84 1051 2.03 1106 2.24 1162 3400 895 1.59 948 1.80 1009 1.98 1057 2.17 1111 2.37 1165 3600 900 1.69 954 1.94 1016 2.13 1065 2.31 1115 2.51 1167 3800 911 1.87 959 2.15 1024 2.35 1070 2.54 1120 2.73 1169 4000 922 2.04 965 2.36 1031 2.57 1077 2.76 1124 2.95 4200 941 2.29 984 2.54 1039 2.73 1083 2.91 1129 3.10 4400 960 2.53 1003 2.71 1047 2.89 1090 3.06 I - 4600 979 2.67 1020 2.86 1061 3.06 I 4800 997 2.80 1036 3.02 I - 2.44 2.57 2.70 2.92 Table 8A Field Supplied Low Static Fan Drive TWE120A3,AW1 Motor Sheave Nominal Turns Open RPM 0 745 1 706 2 666 3 627 4 588 5 549 NOTE: 1. Field supplied components required: Blower Sheave: Fixed Pitch (8.8 inch Pitch Diameter), 1.0 inch Bore, Single Groove, "A" Belt. Belt: A54 5 All dimensions are in inches. Hot Water Coil See vie. B 13 DUCT OPENING Accessory Data Subbase Steam Coil 1 3/8" DIA. HOLE FOR I" NPT (INT) RETURN DUCT OPENING 30 DUCT OPENING DUCT FLANGE 16" 2" DIA. HOLE FOR 2" NPT (INT) SUPPLY DUCT OPENING 9 7/T 1/8" 25 1/4" DUCT FLANGE 16' See Vie. B 25 1/4" 6 HOLES EQUALLY SPACE() AT 17/6" APART /63 5/8" TOP OF UNIT 6 6 HOLES EQUALLY SPACED AT I1 7/8" APAR 63 5/8" TOP OF UNIT 3 1/2" DIA. HOLE FOR 2 1/2" NPT (INT) SUPPLY 3 1/2" DIA. HOLE FOR 2 1/2" NPT (INT) RETURN All dimensions are in inches. Electric Heat Coil REMOVABLE PANEL 12 - 1 /B' DIA. HOLES 16 3/f 5/S (TYP) 12 1/2" 12 - 1/4" Du. HOLES SANE PATTERN AS TOP 3 KNOCKOUTS 7/8'. I 3/8" & 2" 0u, FOR HIGH VOLTAGE 18 1/8' POWER SUPPLY 7/8' I ►/ Discharge Plenum and Grille 63 1/2' Table 9 Discharge Plenum and Grille Dimensions 30 1/4" Hydronic Coil Discharge Plenum and Grille Model No. For Use With A BAYPLNM017 BAYPLNM027 No Heat Electric Heat 28" 29" 7 Table 10 Accessory Weights (Ibs) Accessory Net Hot Water Coil 159 Steam Coil 142 Electric Heat Minimum 27 Maximum 45 Discharge Plenum and Grille Hydronic Heat 97 No Heat 92 Electric Heat 156 Return Air Grille 7 Rubber -in -Shear Isolator Floor Mount 2 Suspended Mount 7 Steel Spring Isolator Floor Mount 12 Suspended Mount 6 Control Transformer 4 Subbase 23 Oversized Motor 50 Table 11 Static Pressure Drop Through Accessories (inches of water column)' Discharge Electric Heaters (KV Hydronic Coils Return Plenum Hot CFM Grille and Grille 5 -10 15 -20 25 -30 35 -50 Steam Water 3200 .07 .43 .06 .13 .19 .26 .42 .40 4000 .11 .66 .10 .20 .30 .40 .59 .56 4800 .15 .95 .14 .28 .42 .57 .76 .75 Notes: 1. Return air filter ESP included in Fan Performance Table data. 2. At louver opening angle of 42 degrees. For ESP at other angle openings, see accessory Installer's Guide. Table 12 Oversized Motor Sheave /Fan Speed (RPM) Sheave Position Unit 6 Turns 5 Turns 4 Turns 3 Turns 2 Turns 1 Turn Model No. Open Open Open Open Open Open Closed TWE120A31 - 915 969 1023 1077 1131 1185 TWE120A32 - 733 776 819 863 906 949 NOTES: 1. High Static motor with 61/2' fan sheave. 2. High Static motor with 8' fan sheave. Table 13 Discharge Plenum and Grille Assembly Throw Distance (Ft.) Louver Angle Deflection Position CFM Straight 20° 40° 55° 3200 56 46 38 30 3600 62 51 42 33 4000 66 57 47 35 4400 71 62 52 38 4800 76 67 56 42 Throw distance values are based on a terminal velocity of 75 FPM. Throw distance values at other terminal velocities may be established by multiplying throw distances in table above by throw factor: Terminal Velocity Throw Factor 50 FPM 1.50 100 FPM .75 150 FPM .50 Table 14 Auxiliary Electric Heat Capacity No. Unit Total of KW BTUH KW BTUH KW BTUH Model No. KW Stages Input Output Input Output Input Output TWE120A1 5.76 1 5.76 19,659 - - 5.76 19,659 11.52 1 11.52 39,318 - 11.52 39.318 17.28 1 17.28 58,977 - - 17.28 58,977 23.04 2 11.52 39,318 11.52 39,318 23.04 78,636 Stage 1 Stage 2 Total 5.00 1 5.00 17,065 - - 5.00 17,065 TWE120A3 9.96 1 9.96 33,993 - - 9.96 33,993 14.96 1 14.96 51,058 - - 14.96 51,058 24.92 2 14.96 51,058 9.96 33,993 24.92 85,051 TWE120A1 28.80 2 17.28 58,977 11.52 39,318 28.80 98,295 TWE120A3 34.88 2 19.92 67,987 14.96 51,058 34.88 119,045 Heaters are rated at240v, 480v, and 600v. For otherthan rated voltage, rapad Vol capacity Rated tage Vol tai a 2 "Rated Capacity. Table 16 - Steam Heating Coil Capacity - Air Handler Steam Pressure (PSIG) Entering Unit Airflow Air Cond. Cond. Cond. Cond. Cond. Tons Model No. (CFM) Temp. (F) LAT' MBh2 Lb /Hr' LAT' MBh2 Lb /Hr' LAT' MBh2 Lb /Hr' LAT' MBh2 Lb /Hr' LAT' MBh2 Lb /Hr' 40 99 203 210 102 214 222 106 229 240 109 241 254 115 261 279 3200 60 112 181 187 115 191 199 119 206 216 123 218 230 129 238 255 80 126 158 164 129 169 175 133 183 192 136 195 206 142 215 230 40 91 222 229 94 234 243 98 250 262 101 264 278 106 286 306 10 TWE120A 4000 60 106 198 204 108 209 217 112 225 236 115 239 252 120 261 279 80 120 173 179 123 184 192 126 200 210 129 214 226 134 236 252 40 86 239 246 88 251 261 92 269 282 94 284 299 99 307 329 4800 60 101 212 219 103 225 233 107 242 254 109 257 271 114 280 300 80 116 186 192 118 198 206 121 215 226 124 230 243 129 253 271 2 PSI 5 PSI 10 PSI 15 PSI 25 PSI Type NS Coil. 1 Row, 1' OD, SF Fins, 132 Fins Per Foot NOTES: 1. LAT - Leaving Air Temperature (F) 2. MBh Capacity: BTU /HR /1000 3. Cond. Lb /Hr - Condensate pound per hour. Table 16 Electric Heat Discharge Plenum and Grille Airflow (CFM) Unit Electric Heater Airflow(CFM) Model No. Model No. Minimum Maximum TWE120A1 BAYHTRL117A BAYHTRL123A 3500 4000 TWE120A3 BAYHTRL315A BAYHTRL325A 4000 3500 TWE120A3' BAYHTRL415A BAYHTRL425A 3500 3500 4800 4800 4800 4800 4800 4800 ore: 1, When wired for 460 volt. 9 Table 17 Hot Water Heating Coll Capacity Entering Water Temperature 180 200 Air Entering 20 Flow Air Water Temperature Drop (F) 30 40 20 30 40 (CFM) Temp. (F) GPM' MBh' LAT' GPM' MBh' LAT' GPM' MBh2 LAT' GPM' MBh2 LAT' GPM' MBh2 LAT' GPM' MBh2 LAT' 40 24.5 239.1 109 14 3 210 0 100 9 1 178 7 91 29 3 284 7 122 17 6 256 8 114 11.7 228.6 106 3200 60 20.2 197.3 117 11 5 168 4 108 6 9 134 8 99 25.0 242 6 130 14 7 215 2 122 9.6 186.9 114 80 15.9 155.6 125 8.6 126.1 116 4 0 78.7 103 20 6 200 6 138 11 9 173.6 130 7.4 144.3 122 40 27.8 271.7 103 16.2 237.5 95 10.3 201.9 86 33.4 324.1 115 19.9 291.0 107 13.3 2581 99 4000 60 22.9 223.8 112 13.0 190.3 104 7.8 153.3 95 28.4 275.8 124 16.7 243,6 116 10.8 211.0 109 80 18.1 176.2 121 9.7 142.6 113 5.0 97.3 102 23 4 227 7 132 13.4 196 2 125 8 4 163.2 118 40 30.7 300.0 98 17.8 261.3 90 11.3 221.7 82 36 9 358 3 109 22.0 320 7 102 14 6 283 7 94 4800 60 25.3 246.9 107 14.3 209.1 100 8.6 168.9 92 31.4 304.7 118 18.4 2681 111 11.9 231.6 104 80 19.9 194.0 117 10.7 156 7 110 5 6 110 2 101 25.9 251 3 128 14.8 215.6 121 9.2 179.4 114 Type W Coil, 2 Row, 5/8" OD, PH Fins, 187 Fins per foot. NOTES: 1. GPM - Gallons per minute 2. MBh Capacity: BTU /HR X 1000 3. LAT- Leaving Air Temperature ( "F) Table 17 (Continued) Hot Water Heating Coil Capacity Entering Water Temperature 210 Water Temperature Drop (F) Air Entering 20 30 40 Flow Air (CFM) Temp. (F) GPM' MBh2 LAT' GPM' MBh2 LAT' GPM' MBh2 LAT' 40 31.7 307.4 129 19.2 279.9 121 13.0 252.6 113 3200 60 27.4 265.1 136 16.4 238.2 129 10.9 211.0 121 80 23.0 223.0 144 13.5 196.5 137 8.7 169.1 129 40 36.1 350.2 121 21.8 317.6 113 14.7 285.5 106 4000 60 31.1 301.7 130 18.5 269.9 122 12.3 238.2 115 80 26.1 253.4 138 15.3 222.3 131 9.8 190.8 124 40 40.0 387.4 114 24.1 350.3 107 16.2 313.9 100 4800 60 34.4 333.6 124 20.4 297.3 117 13.5 261.7 110 80 28.9 279.9 134 16.8 244.6 127 10.8 209,5 120 Type W Coil, 2 Row, 5/8" OD, PH Fins, 167 Fins per foot. NOTES: 1. GPM - Gallons per minute 2. MBh Capacity: BTU/HR X 1000 3. LAT- Leaving Air Temperature ( "F) Table 18 Hot Water Heating Coil - Water Side Pressure Drop at 180 Gallons per Minute (GPM) 2 4 6 8 10 12 14 16 18 20 22 24 28 28 30 32 34 38 Pressure Drop (Ft. of Water) - - .08 .09 13 17 22 27 33 39 48 54 .62 .70 .79 .89 99 Table 18 (Contd.) Hot Water Heating Coil - Water Side Pressure Drop Gallons per Minute (GPM) 38 40 42 44 46 48 50 Pressure Drop (Ft of Water) 1.10 1.21 1,32 1.44 1.57 1.70 1.84 10 Mechanical Specifications General Units shall be completely factory assembled including coil, conden- sate drain pan, fan motor, filters, and controls in an insulated casing that can be applied in either vertical or horizontal configuration. Units shall be tested and certified in accordance with ARI standard 210/240 or 340/360 program. Units shall be UL listed and labeled in accordance with UL 465/ 1995 for indoor blower coil units. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather - resistant baked enamel finish. Casing shall be completely insulated with cleanable, foil faced, fire- retardant, permanent, odorless glass fiber material. All insulation edges shall be either captured or sealed. Knockouts shall be provided for unit electrical power and refrigerant piping connections. Captive screws shall be standard on all access panels. Refrigerant System The TWE120A, single refrigeration circuit, shall be controlled by a factory installed thermal expansion valve. Evaporator Coil Configured aluminum fin surface shall be mechanically bonded to 3/8" internally enhanced copper tubing and factory pressure and leak tested at 375 psig. Coil is arranged for draw - through airflow and shall provide a double sloped condensate drain pan constructed of PVC plastic. The drain pan shall be removable for cleaning. The condensate drain pan can be installed in any of four positions allowing for vertical or horizontal application and providing external connections on either side of the unit. Evaporator Fan Double inlet, double width, forward curved, centrifugal -type fan with adjustable belt drive shall be stan- dard. Thermal overload protection shall be standard on motor. Fan and [rotor bearings shall be permanently ubricated. Oversized motors shall be available as an option for high static application. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls Magnetic evaporator fan contactor, low voltage terminal strip, check valve, and single point power entry shall be included. All necessary controls shall be factory- installed and wired. Evaporator defrost control shall be included to prevent compressor slugging by temporarily interrupting compressor operation when low evaporator coil temperatures are encountered. Filters One inch, throw -away filters shall be standard on TWE120A model air handlers. Filters shall be accessible from the side coil access panel. Filter rack can be field converted to two inch capability. American Standard has a policy of continuous product amd product data improvement, it reserves the right to change design and specification without notice. Technical Literature Printed in USA 2003 American Standard Inc. All rights reserved Mechanical Specifications Accessories Hydronic Heat Coils — One row steam and two row hot water coils shall be available for mounting on the discharge outlet of the air handler. Coils shall be shipped completely factory assembled within a heavy gauge sheet metal casing, finished with enamel to match the blower coil unit. Coils shall be applied in either vertical or horizontal airflow configura- tion. Electric Heaters — UL and CSA approved electric heat modules shall be available for installation directly on fan discharge. Electric heaters shall be available in a wide range of capacities with one or two stage control, single -point electric power connection and terminal strip connec- tions. Electric heater elements shall be constructed of heavy -duty nickel chromium elements internally wye connected on 480/600 volt, three phase and delta connected on 208/ 240 volt, three phase. Each 208/240 volt heater shall have pilot duty with secondary backup fuse links for automatic reset of high limit controls. Each 480/600 volt heater shall have automatic line break high limit controls. Discharge Plenums and Grilles — Accessory discharge plenums shall be available for vertical, free dis- charge applications. Plenums shall be constructed of heavy - gauge, zinc coated, galvanized steel finished with baked enamel to match the air handler unit. Grilles shall be satin finished aluminum and have four -way adjustable louvers. 12 Library Product Section Return Air Grilles — Accessory return air grille shall be provided for vertical front, free return applications. Grilles shall be installed in place of the front lower side panel. Grille shall be satin finished aluminum with non- adjust- able louvers. Mounting Subbases — Accessory available for vertical floor mount configurations. Subbase shall be constructed of heavy gauge, zinc coated, galvanized steel with baked enamel finish to match air handler unit. Subbase is required in the vertical air flow application for conden- sate drain trapping and when isola- tors are required. Vibration Isolators — This accessory shall reduce transmission of noise and vibration to building structures, equipment, and adjacent spaces. Packages shall be available in either neoprene -in shear or spring -flex types in floor or suspended mountings. Oversized Motors — Field installed oversized motors shall be available for high static pressure applications. Control Options Standard Indoor Thermostats — Two stage heating and cooling operation or one stage heating and cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setback Thermostat — This option shall provide heating setback and cooling setup with 7-day program- ming capability. Product Literature Unitary Product Model Literature Type Sequence Date File No. Supersedes Split System Air Handler TWE120A — 10 Ton Submittal 202.12 July 2003 PL- UN- S /S- TWE120 -SQ- 202.12 07/03 TWE 120 -SQ- 202.11 10/01 9 TRAM FILE COPY Model Number TWA12003** * *TWE120D300 Customer: Project: Name: Result 1 6 - 20 Ton Unitary Split Systems Condensing unit type Heat pump units Heat pump electrical characteristics 5 - 20 ton air handler Air handler refrigerant circuit Field applied voltage Heat pump unit 6 -20 Ton Heat Pump 208 - 230/3/60 5 -20 Ton Convertible Air Handler Single Circuit - R410A 208 - 230/3/60 Heat pump nominal cooling capacity Heat pump compressor Airflow Air handler nominal capacity Air handler electrical characteristics Single Compressor - R -410A 4000cfm 10 Tons R -410A 208 - 230/3/60 Main Cooling Cooling EDB Relative humidity Gross total capacity Latent capacity Net sensible capacity Cooling LOB Saturated suction temp 80.00F 51.08% 118.41MBh 24.86MBh 88.98MBh 59.76F 50.77F Cooling EWB Ambient Gross sensible capacity Net total capacity Fan motor heat Cooling LWB Discharge temperature 67.00F 95.00F 93.55MBh 113.85MBh 3.79MBh 58.02F 115.84F Main Heating 208/240 three phase heaters Heating ambient DB Heating ambient RH Net heating capacity Heating delta T Electric heat delta T Motor /Electrical External plus component static pressure Indoor mtr operating power Indoor motor power Compressor power EER Q ARI (cond. unit only) IPLV (cond. unit only) Total power - heat MCA - A.H. MCA - A.H. for 230V w /elect heat MCA - heat pump Compressor 1 RLA Evaporator motor FLA Condenser motor 2 FLA 18.71/24.92 kw 68.00F 70.00% 133.92MBh 32.81F 19.59F 0.300in H2O 1.45bhp 1.32kW 8.40kW 11.OEER 0.0IPLV 10.21kW 71.00A 81.00A 42.60A 30.10A 6.20A 0.00A Heating EAT Heating ambient WB Gross heating capacity Heating LAT Electric Heat Capacity Field supplied low static drive Indoor motor RPM Outdoor motor power Total power EER Q ARI (with air handler) IPLV (system) COP MOP - A.H. MOP - A.H. for 230V w /elect heat MOP - heat pump Compressor 2 RLA Condenser motor 1 FLA External Static Pressure 61.59E 61.59E CODE COMPLI 130.10ME h APPROV 102.81F 85101.80Btuh Not required OR NAY 19 201 i oTu la 682rpm BUILDING DIVI 0.94kW 10.65kW 11.0EER 0.OIPLV 3.85COP 80.00A 90.00A 60.00A 0.00A 5.00A 0.3001n H21VERbArr CENT F. RECEIVED MAY 12 2010 Refrigerant Lines Line length - actual Vertical rise Suction line size od (per circuit) Sight glass part # 100.00ft 25.00ft 1 -3/8 in. GLS00830 Cond. location to A.H. Liquid line size od (per circuit) Est. refrig. chrg / circuit Below air handler 5/8 in. 36.7Ib Misc. Information Solenoid valve part # Evaporator face area Evaporator fin spacing Solenoid valve recommended 11.18sq ft 168.00Each Metering device Evaporator rows Evaporator face velocity Expansion valve 4.00Each 358ft/min AAto Page 1 (gS 1011 Min. A.H. operating weight 0.01b H.P. operating weight 0.01b Max. A.H. operating weight 393.0Ib Max. H.P. operating weight 438.0Ib --4 Page 2 9 MANE SERVICE PANEL SEE NOTE 4 HAIL GUARD (OPTIONAL) SERVICE CLEARANCE 4B' (SEE NOTE 2 FOR CLEARANCE 1/4' 1/4' UNE VOLTAGE CONTROL WIRING UOUID UNE SUCTION UNE 5 9/18' 8 114' o- 4' b d 318' 35 3/4" 42 5/1B' NOTES: 1 .ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY. 2. MINIMUM CLEARANCE FOR PROPER OPERATION IS 36' FROM WALLS, SHRUBBERY, PRIVACY FENCES ETC. MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72'. RECOMMENDED SERVICE CLEARANCE 4B' 3. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100' MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN -OFF WATER DOES NOT POUR DIRECTLY ON UNIT 4 OUTDOOR AIR TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING) HAIL GUARD (OPTIONAL) 40' WITH HAIL GUARD 37 15l18'--.1 SERVICE PANEL 11 / 16" 7 11/16" SERVICE PANEL SIDE 3' 6" 50 3/4' 44 3/4' 2 3/18' 3 13/18' 44 3/4' REFRIGERANT ACCESS 2 7/8' 7118' DI A. ISOLATOR MOUNTING HOLES (OUTSIDE HOLES - 4 PLACES) 3111/18' - - 111/18' 10 TON HEAT PUMP CONDENSER (SINGLE COMPRESSOR) DIMENSIONAL DRAWING 52' WITH HAIL GUARD Page 3 •m4Nr SUPPLY OPENING 5 15116' r3/4' 221/4' 1815116' HEATER CONTROL AND SINGLE POWER ENTRY WIRES HEATER VENTILATION CONTROL WIRING UNE VOLTAGE CONTROL BOX ACCESS PANEL 25 1/2' 3 112' 16 5/16'20 5/16' NOTES. 1 PANEL DEPTH 1/2' (TYPALL PANELS). 2. REMOVABLE DRAIN PAN AND ATTACHED DRAIN CONNECTION MAY BE INSTALLED ON END OF UNIT IN EITHER THE VERTICAL OR HORIZONTAL CONFIGURATION, PLASTIC DRAIN PAN ACCESS PLATE ON THE END OF UNIT OPPOSITE DRAIN CONNECTION MUST BE REMOVED TO SU DE DRAIN PAN OUT OF UNIT FOR CLEANING. ACCESS PLATE MUST BE RE -INSTALLED AFTER SUDING DRAIN PAN BACK INTO UNIT. 3.IF PERIODIC DRAIN PAN CLEANING IS REQUIRED, ALLOW ROOM FOR PARTIAL REMOVAL OF DRAIN PAN CONNECTION AT END OF UNIT. 4. 1' FEMALE SCHED.40 PVC PIPE DRAIN CONNECTION VERTICAL CONFIGURATION. 5. 1' FEMALE SCHED.40 PVC PIPE DRAIN CONNECTION HORIZONTAL CONFIGURATION. 2 1/4' 1 11/18' - 6 13/16' 8 7 /B' 16 1/16' DRAIN CONNECTION FOR HORIZONTAL (SEE NOTE 2,3,5) REMOTE BULB TXV SUCTION UNE 1 3/16' 22 7/8' FILTER ACCESS PANEL 22' MIN. DISTANCE BOTH SIDE LIQUID UNES SEE NOTES 2,3,4 18 11/18' 17 3/8• 2110• V � P 1 11116' p-3 5/8' (4) - HOLEFOR HORIZONTAL SUSPENSION COPPER LIQUID UNE FIELD CONNECTION COPPER SUCTION LINE FIELD CONNECTION 17 3/8' 18 11/18' 4 P 3 5/8' 1 11/16' SUPPLY OPENING SIDE RETURN BOTTOM RETURN SUPPLY VERTICAL - RETURN HORIZONTAL / RETURN VERTICAL 10 TON AIR HANDLER (SINGLE CIRCUIT) BOTTOM RETURN FILTER SIDE RETURN (4) HOLE FOR HORIZONTAL SUSPENSION SEE NOTES 2,3,4 DIMENSIONAL DRAWING SUPPLY HORIZONTAL - RETURN VERTICAL / RETURN HORIZONTAL Page 4 9 MANE ELECTRICAL DATA CONDENSER ELECTRICAL DATA COMPRESSOR MOTOR CONDENSER FAN MOTOR Model: TWA120D3 No 1 No.: 1 Unit Operating Voltage: 187 -253 Volts: 208 -230 Volts: 208 -230 Minimum Circuit Ampecity: 42.6 Phase: 3 Phase: 1 Maximun Fuse Size: 60.0 Amp -RLA: 30.1 Amp -FLA: 5.0 Maximun Circuit Breaker: 80.0 Amp -LRA: 225.0 Amp -LRA: 14 A GENERAL DATA CONDENSER COOLING PERFORMANCE (1X2X3X4)5) COMPRESSOR Gross Cooling Capacity 123,000 Number 1 Matched Air Handler: 114,000 Motors/HP(each): 8.5 Condensing Unit Only: ARI Net Cooling Capacity: 120,000 Motor RPM: 3500 M etched Air Handler: 11.0 No. Compressor/ Tons: 1/6.6 Condensing Unit Only: 12.7 System Integrated Part Load Value: N/A Condensing Unit Only IPLV: N/A SYSTEM DATA (7) System KW /Condensing Unit KW: 10.91 / 6 9B .1 No. Refrigerant Circuits: IEER: 11.8 Suction Line (in.) OD: 1 3 /8' Liquid Line (in.) OD: 516' OUTDOOR COIL OUTDOOR FAN Tube Size (in.) OD 316' No. Used /Diameter (in.): •1 ! 28' Face Area (sq. ft.) 29' Drive Type /No. Speeds: DIRECT! 1 Rows /FPI 2/18 CFM: 9,800 No. Motors/HP: 1 / 1 Motor RPM: 1,100 REFRIGERANT CHARGE (Fld Supplied) (noe) TYPE: R -410A (Circuits #1): 29.0 lb (Circuits #2): N/A NOTES: 1. Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Ratings shown are tested and certified in accordance with ARI 2. Standard 340/380 or 365 certification program. 3. Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and at 05 F ambient. 4. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft. of OD interconnecting tubing. EER is rated at ARI conditions and in accordance with DOE test procedures. 5. Integrated Part Load Value is based on ARI Standard 340/360 or 365. Units are rated at 60 F ambient, B0 F entering dry bulb, and 67 F entering wet bulb at ARI rated CFM. 6. Sound Rating shown is tested in accordance with ARI Standard 270. 7. Refer to refrigerant piping program for line sizing and line length. 8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft. of interconnecting refrigerant lines. All units are shipped with a smell nitrogen holding charge only. Page 5 AIR HANDLER ELECTRICAL DATA CONDENSER ELECTRICAL DATA EVAPORATOR FAN MOTOR Model: TWE120 Unit Operating Voltage: Minimum Circuit Ampecity. 187 -253 7.8 7.3 No: 1 Volts: 208 -230 3 Maximun Fuse Size: Maximun Circuit Breaker: 15 -0 - 15,0 15.0 -15.0 Phase: Motor HP: 2.0 Amp -FLA: 0.2 - 5.8 Amp -LRA: 33.9 - 33.9 GENERAL DATA SYSTEM DATA INDOOR COIL - TYPE No. Refrigerant Circuits 1 Tude Size: '3/0' Suction Line (in.) OD 1 318' Face Area: 11 3/16' Liquid Line (in.) OD 112' Row/FPI 4 / 14 Refrigerant Control EXPANSION VALVE Drain Connection Size 1' PVC INDOOR FAN FILTER Type: 'CENTRIFUGAL Type: THROWAWAY No. Used /Diameterx Width, 1 / 15'X15' Furnished. YES Drive Type /No. Speed: BELT /ADJUSTABEL No Size Recommended: (4) 18'X25'X1' CFM: 4000 No. Motor 1 Motor HP - Standard /Oversized: 2.0 13.0 • Motor RPM: 1725 Motor Frame Size: 58Z HEATER DATA ELECTRICAL DATA Notes: Heat Rating (kW): 18.7/2412 1. KW ratings are at: 208/240V for 208 -230V air handlers Control Stages: 2 480V for 480V air handlers Power Supply: 208 - 230/60/3 Minimum Circuit Ampecity: 73.0/83.0 800V for 575V air handlers M aximun Fuse Size: Fuse Size: 80.0/90.0 _Voltage_ Maximun 80.0/90.0 For other than rated voltage, capacity= ( Rated Vpltage ) a 2 Rated Capacity 2. Any power supply and circuits must be wired and protected in accordance with local electrical codes. 3. The HACR circuit breaker is for U.SA. installations only. 4. With motor field converted to 480V. NOTES: 1. Cooling performance is rated at 95 F ambient, 80 F entering dry bulb. 87 F entering wet bulb 2. Gross capacity does not include the effect of fan motor heat. ARI capacity is net end includes the effect of fen motor heat. Ratings shown are tested end certified in accordance with ARI Standard 340/360 or 385 certification program. 3. Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and at 95 F ambient. 4. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft. of OD interconnecting tubing. EER is rated at ARI conditions and in accordance with DOE test procedures. 5. Integrated Pert Load Value is based on ARI Standard 340/360 or 365. Units are rated at 80 F ambient, 00 F entering dry bulb, and 67 F entering wet bulb et ARI rated CFM. 6. Sound Rating shown is tested in accordance with ARI Standard 270. 7. Refer to refrigerant piping program for line sizing and line length. 8. Refrigerant (operating) charge is for condensing unit (ell circuits) with matching blower coils and 25 ft. of interconnecting refrigerant lines. All units ere shipped with a small nitrogen holding charge only. Page 6 TRAMP SERVICE PANEL SERVICE PANEL #2 #2 #1 WEIGHTS AND LOAD POINT LOCATION #1 WEIGHT AND RIGGING 1 114' DI A. U FT1 N G HOLES (4 PLACES) WEIGHTS AND CORNER WEIGHTS Shippin0: 508.0 lb Net 438.0 lb Comer 1: 121.0 lb Corner 2: 121.0 lb Corner 3: 72.0 lb Comer4: 11B.0Ih Page 7 9 TRANI' HORIZONTAL RETURN #4 01 1 #3 AIR FLOW d VERTICAL RETURN VERTICAL APPLICATION WEIGHTS AND CORNER WEIGHTS Shipping'. 429.0 lb Net 393.0Ib VERTICAL Corner 1: 77.0 lb Corner 2: 121.0 lb Corner 3: 110.0 lb Corner 4: 05.0 lb HORI ZOTNAL Corner A: 79.0 lb Corner 8: 110.0 lb Corner C: 77.0 lb Corner D: 119.0 lb B 0 0 a C #2 A D HORIZONTAL RETURN (— ✓> VERTICAL RETURN HORIZONTAL APPLICATION WEIGHTS AND LOAD POINT LOCATION FOR CONDENSOR I J AIRFLOW WEIGHT AND RIGGING Page 8 ELECTRIC HEATER 13 112' O (12) 114' DIA HOLE SAME PATTERN AS TOP REMOVABLE PANEL 3 KNOCKOUT FOR 718', 1 318' AND 2' DIA CONDUIT POWER SUPPLY ENTRY 87 9118' ELECTRIC HEATER AIR HANDLER 10 TON ELECTRIC HEATER 30 13/18" 12) 114' DIA HOLE SAME PATTERN AS TOP 118' ' 30 11Q'- -x-112' DIMENSIONAL DRAWING Page 9 ®?' General - TWA Weatherproofed Steel Mounting /Lifting Rails Hermetic Scroll Compressors Plate Fin Condenser Coils Fans and Motors Standard Operating Range 50 -1 25F (Min. 0 °F with Low Ambient Accy) Nitrogen Holding Charge Certified and Rated in Accordance with ARI and DOE Standards Certified to UL 1995 Casing - TWA Zinc Coated, Heavy Gauge, Galvanized Steel Weather Resistant Baked Enamel Finish Meets 672 hr Salt Spray Test Removable Single Side Maintenance Access Panels Lifting Handles in Maintenance Access Panels Unit Base Provisions for Forklift and /or Crane Lifting Refrigeration System - TWA Single Compressor (TWA073D, TWA090D, TWA120D) Single Refrigeration Circuit with Integral Subcooling Circuit. Single Direct Drive Hermetic Scroll Compressor with Centrifugal Oil Pump Providing Lubrication To Moving Parts Suction Gas-Cooled Motor w/ ± 10% Voltage Utilization Range of Unit Nameplate Voltage Reversing Valve Crankcase Heater Internal Temperature and Current Sensitive Motor Overloads No Compressor Suction and /or Discharge Valves (Reduced Vibration /Sound) Factory Installed Liquid Line Filter Drier Phase Loss /Reverse Rotation Monitor Liquid Line Service Valve (with gauge port) Suction Line Service Valve (with gauge port) External High Pressure Cutout Device External Low Pressure Cutout Device Evaporator Defrost Control Loss of Charge Protection (Discharge Line Thermostat) Condenser Coil - TWA 3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins Factory Pressure and Leak Tested to 660 psig. Perforated Steel Hailguards Available (Factory Installed Option or Field Installed Accessory) Condenser Fan - TWA 26" or 28" Propeller Fan(s) Direct Drive Statically and Dynamically Balanced Condenser M otor(s) - TWA Permanently Lubricated Totally Enclosed or Open Construction Built -In Current and Thermal Overloads Ball or Sleeve Bearing Type Controls - TWA Centralized MircoProcessor Indoor and Outdoor Temperature Sensors Drive Algorithms Making Decisions for All Heating, Cooling, and Ventilation lntergrated Anti -Short Cycle Timer Integrated Time Delay Between Compressors Completely Internally Wired Numbered and Colored Wires Contactor Pressure Lugs or Terminal Block Page 10 •mwr Unit External Mounting Location for Disconnect Device Single Point Power Entry Hailguards - TWA Condenser Coil Protection from Hail, Vandals, Etc. Perforated, Painted Galvanized Steel Factory or Field Installed General - TWE Completely Factory Assembled Convertible for Horizontal or Vertical Configuration Convertible for Cooling Only or Heat Pump Application Convertible for Left or Right External Connections (Refrigerant and /or Electrical) Convertible for Front or Bottom Air Return Nitrogen Holding Charge Certified and Rated in Accordance with ARI and DOE Standards Certified to UL 1995 for Indoor Blower Coil Units Casing - TWE Zinc Coated, Heavy Gauge, Galvanized Steel Weather Resistant Baked Enamel Finish Access Panels with Captive Screws Completely Insulated with Foil Faced, Cleanable, Fire Retardant, Permanent, Odorless Glass Fiber Materi Captured or Sealed Insulation Edges Electrical Connection Bushings or Plugs Refrigerant Connection Bushings or Plugs Withstand Elevated Internal Static Pressure Refrigeration System TWE Single or Dual Circuit Distributor(s) Thermal Expansion Valves (TXVs) Evaporator Coil - TWE 3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins Factory Pressure and Leak Tested to 449 psig. Draw - Through Airflow Dual Circuits Are Interlaced /Intertwined Double Sloped, Removable, Cleanable, Composite Drain Pan Four Drain Pan Positions Indoor Fan - TWE Double Inlet, Double Width, Forward Curved, Centrifugal Type Fan Dual Fans On 12.5 -20T Air Handlers Adjustable Belt Drive Permanently Lubricated Bearings Indoor Motor - TWE Adjustable Motor Sheaves Thermal Overload Protection Permanently Lubricated Bearings Meet Energy Policy of 1992 (EPACT) Optional Over Sized Motors for High Static Applications Controls - TWE Completely Internally Wired Numbered and Colored Wires Magnetic Indoor Fan Contactor Low Voltage Terminal Strip Single Point Power Entry Evaporator Defrost Control Page 11 Filters - TW E Access From Side Coil Panels Filters Slide on Rack One Inch (1 "), Throw -Away Filters on 5 -10 Ton Units Filter Rack Convertible to Two Inch (2 ") Capability on 5 -10 Ton Units Two Inch (2 "), Throw -Away Filters on 12.5 -20 Ton Units Electric Heaters - TWE Heavy Duty Nickel Chromium Elements cETL Approved Installs Directly On Fan Discharge One or Two Stage Control (Dependent Upon Capacity) Single Point Power Entry Terminal Strip Connections 460V Heaters Internally Wye Connected Automatic Line Break High Limit Controls 230V Heaters Internally Delta Connected Automatic Reset of High Limit Controls Through Pilot Duty with Secondary Backup Fuse Links Page 12 * PER IT C RD COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -063 PROJECT NAME: VERIZON WIRELESS DATE: 05/12/10 SITE ADDRESS: 132 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: . Mvision B i in Public Works 41ili Fire Preven ion I !. Planning Division nStructural ❑ Permit Coordinator C DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete KI Comments: Incomplete n DUE DATE: 05/13/10 Not Applicable Permit Center. Use Only - ': ��e'- "p�" r • • INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/10/10 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Mckinstry Co Llc UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State Wa Expiration Date 3/16/2012 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JL Lydig + Mckinstry Llc Construction Contractor General Unused 4/13/2010 4/13/2012 Active WESTVI'121RF Westvent Inc Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN "372ND Mckinstry Co ry Construction Contractor General Unused 8/20/1963 1/2/2008 Relicensed Business Owner Information Name Role Effective Date Expiration Date Pedersen, Jamie D Agent 03/16/2006 Amount Allen, Dean C Partner /Member 03/16/2006 CP0399990301 Moore, Douglas J Partner /Member 03/16/2006 Allen, David E Partner /Member 03/16/2006 ZURICH AMERICAN INS CO Teplicky, Joseph Partner /Member 03/16/2006 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS & SURETY CO 104702039 01/03/2006 Until Cancelled $12,000.00 03/16/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009 01/31/2011 $2,000,000.00 12/07/2009 2 ZURICH AMERICAN INS CO CP03999903 01/31/2008 01/31/2009 $2,000,000.00 01/31/2008 1 CHARTER OAK FIRE INS CO DTC052D7193COF07 01/31/2006 01/31/2009 $1,000,000.00 01/08/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 05/24/2010