Permit M10-069 - DIGITAL FOREST - UPS ROOM
DIGITAL FOREST UPS ROOM 12101 TUKWILA INTERNATIONAL BL EXPIRED 12 -1x-10 M10 -069 City ckukwila a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 0923049031 Address: 12101 TUICWILA INTERNATIONAL BL TUKW Project Name: DIGITAL FOREST - UPS ROOM Permit Number: M10 -069 Issue Date: 06/17/2010 Permit Expires On: 12/14/2010 Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUICWILA INTERNATIONAL BLVD , SEATTLE WA 98168 Contact Person: Name: JARED SHEEKS Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Email: JARED.SHEEKS @MACMILLER.COM Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206 768 -3806 Phone: 206 - 768 -4180 Expiration Date: 12/31/2010 DESCRIPTION OF WORK: INSTALL (1) 15 -TON PACKAGE ROOFTOP A/C UNIC, SUPPLY DUCTWORK AND TIE INTO EXISTING DUCTWORK. INSTALL (1) BACKDRAFT DAMPER. INSTALL (1) MOTORIZED CONTROL DAMPER. (SEE PREVIOUS EXPIRED PERMIT M08 -228.) Value of Mechanical: $17,742.00 Type of Fire Protection: Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied mine 'th, w Fees Collected: $362.06 International Mechanical Code Edition: 2009 Date: Ole 1 it 1J this permit and know the same to be true and correct. All provisions of law and ordinances ether specified herein or not. The granting of this permit does not presu - o give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. (Pit Signature: Date: `-i t ? /1 0 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -069 Printed: 06 -17 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 0923049031 Permit Number: M10 -069 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 05/27/2010 Tenant: DIGITAL FOREST - UPS ROOM Issue Date: 06/17/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of arty construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with art automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M10 -069 Printed: 06 -17 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10-069 Printed: 06 -17 -2010 • • wq� City of Tukwila 3 \Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 2 Date: - ' ' /iv ordinances governing or local laws regulating doc: Cond -10/06 M10 -069 Printed: 06 -17 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Permit No. M i° Project No (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 0923049031 Site Address: 12101 TUKWILA INT'L BLVD TUKWILA, WA 98168 Suite Number: 410 Floor: Tenant Name: DIGITAL FOREST - UPS ROOM Property Owners Name: INTERNATIONAL GATEWAY WEST 4 New Tenant: ❑ Yes 0 .. No Mailing Address: 12201 TUKWILA INT'L BLVD SEATTLE WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: JARED SHEEKS Day Telephone: (206) 768 -3806 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City E -Mail Address: JARED.SHEEKS @MACMILLER.COM Fax Number: State Zip MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 Contact Person: JARED SHEEKS E -Mail Address: JARED.SHEEKS @MACMILLER.COM Contractor Registration Number: MACDOFS980RU City State Zip Day Telephone: (206) 768 -3806 Fax Number: Expiration Date: 12/31/2010 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Contact Person: JARED SHEEKS Day Telephone: (206) 768 -3806 E -Mail Address: Fax Number: Zip H:\Applications \Forms- Applications On Line \2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 1 of 2 • Valuation of Project (contractor's bid price): $ 17,742 Scope of Work (please provide detailed information): INSTALL (1) 15 -TON PACKAGE ROOFTOP A/C UNIT, SUPPLY DUCTWORK AND TIE INTO EXISTING DUCTWORK. INSTALL (1) BACKDRAFT DAMPER. INSTALL (1) MOTORIZED CONTROL DAMPER. THIS IS A RE- APPLICATION FOR EXPIRED PERMIT M08 -228 Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment 2 Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 _' • UTHORIZED • . • T: Signature: Print Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW Date: 05/27/2010 Day Telephone: (206) 768 -4278 SEATTLE WA 98106 City State Zip Date Application Accepted: ii, l% Date Application Expires: I t.1 ItO Staff Initials: Ar H:Wpplications\Forms- Applications On Line \2009 Applications \1-2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0923049031 Permit Number: M10 -069 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 05/27/2010 Applicant: DIGITAL FOREST - UPS ROOM Issue Date: Receipt No.: R10 -00943 Initials: User ID: Payee: JEM 1165 Payment Amount: $362.06 Payment Date: 05/27/2010 11:24 AM Balance: $0.00 MACDONAL- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2506 362.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 289.65 000.345.830 72.41 Total: $362.06 PAYMENT RECEIVED doc: Receiot -06 Printed: 05 -27 -2010 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBE CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4447 Project: /0 r i.5 H 1 al Type of Inspection• Address: ! z i c / Suite #: 1.6 Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. ECorrections required prior to approval. COMMENTS: y Needs Shift Inspection: f Sprinklers: Alarm: Hood & Duct: _Fire Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -2.1 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record:Form.Doc 1/13/06 T.F.D. Form F.P. 113 Steve Flink Account Manager MacDonald - Miller Facility Solutions 2500 South Holgate Tacoma, WA 98402 Mr. Flink: POGGEMEYER DESIGN GROUP FILE COPY August 22nd, 2008 RE: Digital Forest UPS Room RTU, Roof Capacity Verification for Proposed HVAC Unit Installation We have reviewed the loading effects of the proposed Trane Voyager TCD -180 mechanical unit, which has a maximum operating weight of 2,000 lbs., which will be located on the roof of Intergate West Building "C" between grids A -B, bay 2 -3, as shown per attached sketch SK -1. The unit shall be installed with the accessory -roof curb in order to more effectively distribute the weight of the structure to the two joists. Our review of the proposed HVAC unit included analysis of gravity loads and possible seismic lateral loading, as determined per the International Building Code (2006 Edition) and the ASCE 7 -05 codes. We have determined that the roof has sufficient capacity to support the loading demands imposed by the proposed unit. Please feel free to call me at (425) 827 -5995 for any further question or clarifications. Sincerely, Ben Fisher Project Engineer Poggemeyer Design Group Phone: (425) 827 -5995 Fax: (425) 828 -4850 Enclosed: SK -1 CC: Poggemeyer File -REVIEVVED FOR E CODE CO APPROVED JUN 16 2010 City of Tukwila BUILDING DIVISION CIAFTSILA MAY 2 7 2010 PERMIT CENTER pito-o(pi 512 6th Street South, Suite 202 I Kirkland, Washington 98033 I P 425.827.5995 I www.poggemeyer.com POGGEMEYE'a�;'e Cons ,,e; `r ~n1 No • :� A;.t; -;r'. 512 6th Street So ite 202 (4251 827 - 999'`` FAX IGN GROUP seers .ion • Kirkland, WA 98033 (425) 828 -4850 ROOF Made by BSF Date 8/12/08 Job No. 8035 Checked by Date Sheet No SK -1 Description TRANE VOYAGER TCD -180 TO ROOF AT INTERGATE WEST BLDG HVAC ATTACHMENT Job Name DIGITAL FOREST C 2� 15'— 0'— 3'— 5t itn. %.`Yw.'�i.t11 0) TRANE HVAC UUIT TTACHMENT TO ROOF PER MANUFACTUPER r ' TRANU • V,OYAGER`. rECD- .100'; x•(2000 LOS) ROOF AREA WITH HVAC OVER UPS ROOV - N �- ENLARGED AREA UPS ROOM AT SCALE: 1/8" = 1' -0" OOF 0 � • 0 a I0 °I ° ,., ° .. ° ,. ° . u ®,,. t � LI I .��' ' ��I IT Iii 1 1 di i i i -il ; ' ■ i 11 i I ! r � -- iii,M�,�E �, \�� ..IM,1 � _I - , PIN 1 .NSF .I _ 111311 • ; � 1L 1 - 1 --' I I �RANE V A'�' R ob 1 tfu'D— ao 11 TOP HbA UNIT _ BLDG C ROOF PLAN SCALE: NTS 0 8035— S1.DWG POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 Made by 1'�F Date $I Z $ Job No- Checked by Date Sheet No Description tJ pS (yGpM titl/�v Job Name Pitt t-nkt. rQt\ e4i- ,e[ .einA IL best GteJ GA 74er /Noy, II—At—1 IR-At-le. V6140.044, TGp -lino Voyept 000 Items: AC-1 Oty 1 Tape AC-1 00020011:17:30 PM 019101 FOns; T1 %Qiir�— TRANE' 1Ir 01A HOLE poor CONTROL vARq DOWNFLOW ISOMETRIC- PACKAGED COOLING WITH ELECTRIC HEAT 5EIe,Mw Dxy(r^r4 ro it,ce C iT• tg.�) cif&(< rAo)L6 142.E -I tQ• 13.3- 47'43 0.144- Sot' 0.'03 aP ; 2.5 �� X0.0 Fr T v S5 P CI t 2 ) C,'w -t.o °l °I- V. 4-- fa. 13.9- a- FPrMAx ° I.(' • %4 • i(• for ` 3 0-6 (N`Pry..) Ea. 13.$- 3 Pr,t„,,.) ' 0.7, • Sos • Sao • w ` 'S $(0-E1 (r.4" ) Loa cArA6,,-, trrtod 5 orP to-A'iA 1265 ru cAnti� POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (42S) 828 -4850 Made by 7.5r Date 4I►Liol. Job No. Checked by Date Sheet No. Description Up (AuoAA RAJA Job Name D(a( -A , F> ,1 �(ff isA<G 94e (A ri 0.1.4;p4 1.4t GP IP-I - O.Lt2oy wQ : - 31 Oft Ho1Ovwro tvckn or3 AT 0) 464 OF w= 11'4 Q ¢ Io1" k.4 g�N Gib � r (lo00o)(26 ") -' (3010')(3 ") ` Iticwo (14-1,7 \I : • c (V140 (x' (39 ZoO vPu F r ?I" Gat6Z m : (,000 (X' rM)— (W7 : 61q &o ,,4 -I VC Mg %ftilt IN- 16iti (7'i` uPv(Fr log " uPI/lfr Ovw r t ) t 4-C Cyr 44 A41- 200# ()Quit I' eevi' C 2504 VP) y &O# 170w r-4 I /Feuer, ( ° % Fevr) 1265 (a.r -I pep a- e (En- Foo T' POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS 512 Sixth Street South, Suite 202 • Kirkland, WA 98033 (425) 827 -5995 • Fax (425) 828 -4850 Made by f!, F Date $11140 $ Job No. Checked by Date Sheet No. Description VP (r 't vi JAL Job Name 1710,11) /t v kver eie tS Nit!// (.t rt4gJ till � eG�" b (2-1(4,/./1-t- 20 o OEGfc 02 5 G k ^J I I (y " h P % I `6 A A . wry/ 1.15 6 co m - (,)k-to) o) ' /`r 6K. PJDPLFi vuet.45 gA• JKwwi e7eft4A we1,o hr06- t.M PS yr O.G. D«iVaL-A AA vA tJ & 5 1>v, &I-C" Ntih'% C'-' " SP,NI or I.f t c /t,F (Inv{'-) q,44.r v A' UG (/, J t foNM 1,04 Igto (p 7f UN 1r Ir>°I 6r S 92,/040.n x y -q o Dkf. Poo? oecAo. AoeavakTV 301e,T7 C (( . L 1-00 y- VC-61 �t,�GaRrr1 (W<1 Of -D" o.t. 4(n4 s At.e`' 10 pn. (,o A Q 113 (' (. P 1,04-o = *S& fur ((-ooh - tv Lade).. (aao R 2 c-' NO ; 51'0 " e T) ?live(% it 00' Jol`it4 Mr ./ P 166 A t9 G AtiG9 • - .493k /ft JAALAAAMALANNAAAAJOUAAAAADA/11 AAAAAAAIIA A 4.8 4.8 Loads: LC 1, LC- DESIGN Results for LC 1, LC- DESIGN Member Bending Moments (k -ft) Reaction units are k and k -ft oggemeyer Design Group BSF -23.4 Design Load Diagram Aug 12, 2008 at 11:52 AM 16K4 TEST.r2d Beam: MI Shape: RE4X4 Material: gen_Conc3NW _ength: 19.5 ft I Joint: N1 J Joint: N2 LC 1: LC- DESIGN Code Check: 0.000 (bending) Report Based On 97 Sections A k fa ksi V 4 807 at 0 ft -4.807 at 19.5 ft k 26.362 at 9.75 ft ksi - 23.433 at 9.75 ft k -ft - 26.362 at 9.75 ft ksi - 23.829 at 9.75 ft in - .25k /ft -.2k /f A A • AAAAAAAAAAAAAA A1A11V1A 1A AA AAAAAAAAAA AAAA 3.5 -13.8 Loads: LC 2, LC- PROPOSED Results for LC 2, LC- PROPOSED Member Bending Moments (k -ft) Reaction units are k and k -ft AA 2.6 oggemeyer Design Group BSF PROPOSED LOAD CASE Aug 12, 2008 at 11:52 AM 16K4 TEST.r2d Beam: MI Shape: RE4X4 Material: gen_Conc3NW - ength: 19.5 ft I Joint: N1 J Joint: N2 LC 2: LC- PROPOSED Code Check: 0.000 (bending) Report Based On 97 Sections A k fa ksi V 3.459 at 0 ft -2.625 at 19.5 ft k 15.502 at 8.938 ft -13.78 at 8.938 ft k -ft ft - 15.502 at 8.938 ft ksi - 14.176 at 9.547 ft in Voyager TCD Items: AC -1 Qty.: 1 Tags: AC -1 6/30/2008 1:17:30 PM Digital Forest TI 414 �- TRAM" 50 1 /8" Gil �� \ \ \1 (7 igiBrA 6 5/8" DOWNFLOW CONDENSATE DRAIN CONN 1" NPT 25 1/2" 106 11/16" SERVICE GAUGE PORT ACCESS 70 13/16" 2" DIA HOLE (UNIT POWER WIRE) 7/8" DIA. HOLE (UNIT CONTROL WIRE) DOWNFLOW ISOMETRIC - PACKAGED COOLING WITH ELECTRIC HEAT —•- 1811/16" - — 221/2" 4 1!4" 26 7/16" t 4 1/4" 54 11/16" SUPPLY 62 7/16" RETURN THROUGH THE BASE ELECTRICAL (SEE ACCESSORY SHEET) DOWNFLOW - PENATRATION TOPSS Dimension Drawing ALLW ELHTS AND D111ENSDNS ARE APPR0XI1ATE. CERTFED PRNTS ARE AVALABLE UPON REQUEST. Page: 1 Voyager TCD Items: AC -1 Qty: 1 Tags:"AC -1 6/30/2008 1:17:31 PM Digital Forest TI Aft F ELECTRICAL / GENERAL DATA GENERAL Tons: 15 Unit Operating Voltage Range: 414 -506 Unit Hertz: 60 Unit Primary Voltage: 460 Unit Phase: 3 Unit Secondary Voltage: - EER: 9.9 Standard Motor Oversized Motor Field Installed Oversized Motor Minimum Circuit Ampacity: 39.0 Minimum Circuit Ampacity: 42.0 Minimum Circuit Ampacity: N / A Maximum Fuse Size: 50.0 Maximum Fuse Size: 50.0 Maximum Fuse Size: N / A Maximum (HACR) Circuit Breaker: 50.0 Maximum (HACR) Circuit Breaker: 50.0 Maximum (HACR) Circuit Breaker: N / A HEATER Heater kW Rating: N / A Standard Motor with Heat Stage N / A Oversized Motor Field Installed Oversized Motor Minimum Circuit Ampacity: N / A Minimum Circuit Ampacity: N / A Minimum Circuit Ampacity: N / A Maximum Fuse Size: N / A Maximum Fuse Size: N / A Maximum Fuse Size: N / A Maximum (HACR) Circuit Breaker: N / A Maximum (HACR) Circuit Breaker: N / A Maximum (HACR) Circuit Breaker: N / A COMPRESSOR OUTDOOR MOTOR Circuit #1 Circuit #2 Number: 1 Number: 1 1 Horsepower: .50 Horsepower: 9.3 5.1 Motor speed (RPM): 1,100 Phase: 3 3 Phase: 3 Rated Load Amps: 16.3 10.0 Full Load Amps: 1.6 Locked Rotor Amps: 113.0 63.0 Locked Rotor Amps: 3.8 INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: 1 Number: 1 Number: N / A Horsepower: 3.0 Horsepower: 5.0 Horsepower: N / A Motor Speed (RPM): 1,740 Motor Speed (RPM): 3,450 Motor Speed (RPM): N / A Phase: 3 Phase: 3 Phase: N / A Full Load Amps: 4.8 Full Load Amps: 7.6 Full Load Amps: N / A Locked Rotor Amps: 40.5 Locked Rotor Amps: 54.9 Locked Rotor Amps: N / A POWER EXHAUST ACCESSORY FILTERS REFRIGERANT (Field Installed Power Exhaust) Type: R -22 Horsepower: N / A Type Throwaway Factory Charge Motor Speed (RPM): N / A Furnished: YES Phase: N / A Number: 21 4 Circuit #1: 17.5 lb Full Load Amps: N / A Recommended Size: 20" x 20" x 2" / 20" x 25" x 2" Locked Rotor Amps: N / A Circuit #2: 9.5 lb NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at ARI conditions and in accordance with DOE test procedures. TOPSS Dimension Drawing ALLW ELHTS AND DIMENSDNS ARE APPROXIMATE. CERTFED PRIJTS ARE AVALABLE UPON REQUEST. Page: 2 Voyager TCD items: AC -1 (]ty; 1 Tags: AC -1 6/30/2008 1:17:31 PM Digital Forest TI ‘11 TIMNE 50 1/8" 6 5/8" DOWNFLOW CONDENSATE DRAIN CONN 1" NPT 48 3/8" SINGLE POINT POWER ENTRY 106 11/16" SERVICE GAUGE PORT ACCESS 70 13/16" 2" DIA HOLE (UNIT POWER WIRE) 7/8" DIA. HOLE (UNIT CONTROL WIRE) DOWNFLOW ISOMETRIC - PACKAGED COOLING WITH ELECTRIC HEAT 4 1/4" 4 1/4" L 18 11/16" 22 1/2" - —26 7/16" 62 7/16" RETURN 54 11/16" SUPPLY 0 DOWNFLOW- PENATRATION TOPSS Dimension Drawing ALLW ELHTS AND DE ENSDNS ARE APPR0XB1ATE. CERTFED PRINTS ARE AVAIABLE UPON REQUEST. Page: 3 Voyager TCD Items: AC -1 Qty_ 1 Tags: AC -1 6/30/2008 1:17:32 PM Digital Forest TI T E" CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT MUST BE ADDED. RIGGING AND CENTER OF GRAVITY TOPSS Dimension Drawing ALLW EL FITS AND DIM ENSDNS ARE APPROXIMATE. CERTFED PRINTS ARE AVALABLE UPON REQUEST. Page: 4 ACCESSORY WEIGHTS ECONOMIZER 65.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER HEATER OVERSIZED MOTOR 5.0 Ib HIGH STATIC DRIVE HIGH EFFICIENCY MOTOR (FIOPS) THROUGHT THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) TOOL -LESS HAIL GUARD (FIOPS) POWER EXHAUST ROOF CURB 205.0 Ib BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET O 547.0 Ib © 234.0 Ib (E) LENGHT (F) WIDTH 1866.0 lb 1498.0 Ib ( 358.0 Ib © 359.0 Ib 42" • 28" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT MUST BE ADDED. RIGGING AND CENTER OF GRAVITY TOPSS Dimension Drawing ALLW EL FITS AND DIM ENSDNS ARE APPROXIMATE. CERTFED PRINTS ARE AVALABLE UPON REQUEST. Page: 4 Voyager TCD items: AC -1 Qty; 1 Tags: AC -1 6/30/2008 1:17:33 PM Digital Forest TI TINE" CLEARANCE 68" CLEARANCE 36" CLEARANCE 60" CLEARANCE 48" DOWNFLOW - PACKAGED COOLING WITH ELECTRIC HEAT CLEARANCE UNIT OUTLINE 62 1/2" DOWNFLOW - PACKAGED COOLING WITH ELECTRIC ROOF OPENING CLEARANCE TOPSS Dimension Drawing ALLW ELHTS AND DEENSDNS ARE APPROXIIATE. CERTFED PRINTS AREAVALABLE UPON REQUEST. Page: 5 Voyager TCD items: AC -1 Qty; 1 Tags: AC -1 6/30/2008 1:17:33 PM Digital Forest TI lift i E" 66 101 7/8" 14 1/16" ACCESSORY -ROOF CURB 1" 17 3/4" 59 7/1 , 1" 25 11/16" (7 7/16" 14 1/16" • 1 13/16" ACCESSORY - DOWNFLOW DUCT CONNECTIONS TOPSS Dimension Drawing ALLW ELHTS AND DT1ENSDNS ARE APPR0Xt1ATE. CERTFID PRNTS ARE AVALABLE UPON REQUEST. Page: 6 2° nN 400 k510 - 1 13/16" -1 13/16" 20 7/8" —.- 1"1" f 17 1/8" 28 1/2" 1" 63" 5/8" r\ 7 67 t RETURN 1 55 SUPPLY 1/2" Z v 1 n9 1 /d" ACCESSORY -ROOF CURB 1" 17 3/4" 59 7/1 , 1" 25 11/16" (7 7/16" 14 1/16" • 1 13/16" ACCESSORY - DOWNFLOW DUCT CONNECTIONS TOPSS Dimension Drawing ALLW ELHTS AND DT1ENSDNS ARE APPR0Xt1ATE. CERTFID PRNTS ARE AVALABLE UPON REQUEST. Page: 6 Voyager TCD !terns: AC -1 Qty: 1 Tags:AC -1 6/30/2008 1:17:35 PM Digital Forest TI mum- DOWNFLOW ACCESSORY- ECONOMIZER TOPSS Dimension Drawing ALL W ELHTS AND DI1ENSDNS ARE APPROXIMATE. CERTFED PRINTS ARE AVALABLE UPON REQUEST. Page: 7 Dimensional Data Figure 9. Cooling with Optional Electric Heat and Gas /Electric Models - 121/2 -171/2 Tons Standard Efficiency; 121/2 Tons High Efficiency * All dimensions are In Inches /millimeters. * *1/2 NPT Gas Connection = (Y_C Models only); 2" Electrical Connection: Single Point Power When Heat Installed (T_C Models only.) FILTER ACCESS DOOR HORIZONTAL DOWNFLOW CONDENSATE DRAIN CONN 1' (25 4MM) NPT 71 5/B" 1819.2BMM 107 5/16' 2725.74MM 50 1/8" 1273 8M SINGLE POINT POWER ENTRY 106 11/16" 2709.87MM .50 (12.3MM) NPT GAS INLET (YC'100 -H -.75 (19.05MM) NPT) (VC'210 -H - .75 (19.05MM) NPT VC' MODELS ONLY 70 13/16' 1798.64MM 7 (50.8014M) DIA HOLE (UNIT POWER WIRE) 715' (22_23MM) DIA. HOLE (UNIT CONTROL WIRE) SERVICE GAUGE PORT ACCESS 116 RT- PRCO24 -EN 1 t ". Vv 1 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director January 18, 2011 Darla Doll MacDonald Miller 7717 Detroit Ave SW Seattle, WA 98106 RE: Request for Extensions Mechanical Permit No. M10 -047 and Dear Ms. Doll, This letter is in response to your written request for an extension to Permit Numbers M 10 -047 and M 10 -069. The Building Official has reviewed your letter and considered both your requests. The City of Tukwila Building Division will be extending M10 -047 an additional 180 days from the date of expiration, through July 8, 2011. On the other hand, permit M10-069 expired prior to the request for extension and will not be extended. The expiration date remains as December 14, 2010. In order for additional work or inspections to be conducted for this project, a new permit will need to be applied and paid for. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, ifer Marshall it Technician W: \Permit Center \Extension Letters\Pennits \2010\M10 -047 Pennit Extension.doc 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 City of Tukwila — Permitting Department To: Tukwila Building Official Subject: Permit Extension for # M10 -047 & M10 -069 To Whom It May Concern: We would like to request another extension for Perri it #M10 -047; it is due to expire on 1- 10-11. We had hoped the Electrical Contractor would ha had is inspection by Friday, Jan 7th but we just learned that his work is not complete. We cannot Final our permit until their permit is complete and final. We are waiting for them to do the Final Inspection on the Fire /Smoke Test. Our work has been complete for over a year. Permit M10 -069, unfortunately expired on 12- 14 -10. With all of the other permits waiting._ Cry K. -- c A Paw it 460 Lie NP6 DI- GoII A 0,101 {ll on the Electrical Contractor we missed extending this permit. It was originally un er M08 -228 but that expired and we had to resubmit again for a new permit. The scope.of the_wgr is still-- the same and we are asking if it is possible to allow us to reopen and exti<nd M10 -069 We would like to avoid paying the permit fees for a third time but understand/that we should have extended the permit. Again, our work has been completed for over a year and we are only waiting on the other Contractor to complete his Final Inspection. If you have any questions or would like to discuss these projects please contact me at (206) 768 -4278 or by e-mail at Darla.doll @macmiller.com. Thank you, Darla Doll MacDonald Miller ti 0 —004 , OWC1 to t)ek C bL�LeLl ?EMIT CENTER : C iaLL C* �7Ci L i LC' 11 -01 -2010 1 Jim Haggerton, Mayor Department of Comma r. itp/ eielopment Jack Pace, Director JARED SHEEKS 7717 DETROIT AV SW SEATTLE WA 98106 RE: Permit No. M10 -069 12101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/14/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 12/14/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Jenni nn er Marshall t Technician File: Permit File No. M 10 -069 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206- 431 -3665 ®ER 1T CO RD COP, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -069 DATE: 05/27/10 PROJECT NAME: DIGITAL FOREST - UPS ROOM SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS: f _ C 0 A4C. (.Q'* -tO I ding ivision re Prevention Public Works nStructural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06/01/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/29/10 Approved ❑ Approved with Conditions VI. Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr ter Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Macdonald /Miller Fac Sol Inc UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite /Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State Wa Expiration Date 12/31/2010 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC Divco Incorporation Construction Contractor General Unused 12/3/2002 11/7/2010 Active MACDOMR026RU Macdonald Miller Rsdntl Inc Construction Contractor Unused General 12/31/1998 12/31/2001 Archived MACDOMR0760P Macdonald Miller Residential Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC Divco Energy Control Company Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM *248J9 Macdonald Miller Co Construction Contractor General Unused 4/29/1976 2/1/2002 Archived ENCOMMS984CA Encompass Mechanical Services Construction Contractor General Unused 2/1/2002 2/1/2004 Expired LINFOAR980QG Linford Air ftAmp; Refrigertn Inc Construction Contractor General Unused 11/7/2002 11/7/2004 Inactive DIVCOI *031L4 Divco Inc Construction Contractor General Unused 6/24/1997 8/1/2003 Relicensed Business Owner Information Name Role Effective Date Expiration Date Turley, Douglas Chief Executive Officer 02/13/2008 Turley, Douglas Chief Operating Officer 02/13/2008 Webster, Mark E Member 05/14/2010 Hoel, Stephanie W Member 05/14/2010 https://fortress.wa.gov/lni/bbip/Print.aspx 06/17/2010 1 PACKAGED ELECTRIC AIR CONDITIONING SCHEDULE UNIT NO. MFG & MODEL NO. NOM TONS SUPPLY FAN OA CFM EXH FAN COND FAN EER/ IPLV ELECTRICAL WT LBS NOTES CFM ESP QTY HP QTY HP QTY HP VOLT /PH MCA AC-1 TRANE SXHFC75 75 14/12 W 4/ 12e- 2 BARE ROUND SHEETMETAL 2 20 6 1 14/ 12$W • 460/3 . 11000 1 AC -2 AAON RN -070 70 25000 2 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 1 AC -3 AAON RN -070 70 25000 2 2 15 1000 • 2 3 6 3/4 9.4110.1 • 460/3 157 7000 1 AC -4 AAON RN -070 70 25000 2.0 2 15 1000 2 3 6 3/4 9.4/10.1 . 460/3 1.57 7000 1 AC -5 AAON RN -070 70 25000 2.0 2 15 1000 2 3 6 3/4 9.4/10.1 460/3 157 7000 2 RTU -1 . TRANE TFD -180 15 6000 1.0 1 5 200 - - 2 1/2 9.9/10.2 460/3 42 2000 3 NOTES: 1. EXISTING ROOFTOP AIR CONDITIONING UNIT TO REMAIN. 2. FUTURE ROOFTOP PACKAED AIR CONDITIONING UNIT. 3. NEW ROOFTOP PACKAGED AIR CONDITIONING UNIT WITH THE FOLLOWING FEATURES /ACCESSORIES: R -22 REFRIGERANT (2) SCROLL COMPRESSORS 100% ECONOMIZER WITH BAROMETRIC RELIEF ACCESSORY (CANFAB 6107 -EC). RETURN AIR SMOKE DETECTOR - CONNECTION TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR FACTORY MOUNTED DISCONNECT - ELECTRICAL CONNECTION BY ELECTRICAL CONTRACTOR FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt a1 approved Field Copy and conditions is acknowledged: By, zi Date:. to % 1 /i City Of Tukwila BUILDING DIVISION No changes shall Vg ISI m d -- to the scope of work without prior approval of Tukwila Building Division. will rrquir� rl =,y plan submittal Wen SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical feElectrical ettumbing tas Piping City of Tukwila BUILDING DIVISION 0 0 E HVAC ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP cc CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER. RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT 110 M-M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD - MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS TV TWG TWR TYP UNO VD VFD OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER ROUND SHEETMETAL WRAPPED W /INSULATION (2 ") GREENHECK DFD 150 (HORIZONTAL MOUNT) OR EQUAL . • 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER 14/12 120W GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER ® GREENHECK FSD 231•OR EQUAL 3 HOUR HORIZONTAL COMBINATION FIRE/SMOKE SOUNDLINE SHEETMETAL (1" LINING) HFSD © GREENHECK FSD 231 OR EQUAL SMOKE DAMPER CLEANROOM QUALITY DUCTWORK 0 co s 0 o 0 z w O 14/12 SL 14/12 C Q 2 M D 1- ,CC BUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER SHOP FABRICATED, W/ LOCKING QUADRANT SHEETMETAL WRAPPED W/ INSULATION (2 ") INTERLOCK WITH FIRE ALARM BY ELECTRICAL CONTRACTOR ACCESS DOOR BARE FLAT OVAL SHEETMETAL CONSTRUCTION BY GENERAL CONTRACTOR 14/12 W 4/ 12e- FIRE DAMPER REQUIREMENTS: - BLADES OUT OF AIRSTREAM ON MEDIUM PRESSURE. DUCTS -165 F FUSIBLE LINK - CLASS 0 BARE ROUND SHEETMETAL FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 120 14/ 12$W • EXPOSED QUALITY SHEETMETAL DUCTBOARD (1" FIBERGLASS) 14/12 0 14/12 DB EXAMPLE OF NEW EXAMPLE OF NOT IN CONTRACT (NIC) _ _ 14/ _ 14/12 EXAMPLE OF DEMO FLEX DUCT xxxxxxx xxxxxxx EXAMPLE OF EXISTING FLEX CONNECTOR 14/12 3 i DAMPER LEGEND SYMBOL DESCRIPTION- POWERED SYMBOL DESCRIPTION -NON POWERED 1 1/2 HOUR VERTICAL COMBINATION FIRE/SMOKE FD ® HFD ® . FD • HFD 41 FD • 1 1/2 HOUR. CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER FSD $ GREENHECK FSD 212 (2000 FPM) OR EQUAL GREENHECK FSD 312 (3000 FPM) OR EQUAL .1 1/2 HOUR HORIZONTAL COMBINATION FIRE/SMOKE HFSD 410 GREENHECK FSD 212 (2000. FPM ).OR EQUAL • GREENHECK FSD 312 (3000 FPM)'OR EQUAL " TFSD 1 1/2 HOUR TUNNEL CORRIDOR COMBINATION FIRE /SMOKE GREENHECK DFD 150 (HORIZONTAL MOUNT) OR EQUAL . • 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER .:: GREENHECK DFD• 350 OR EQUAL 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER ® GREENHECK CFSD 212 -1.OR EQUAL 3 HOUR VERTICAL COMBINATION FIRE/SMOKE FSD GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER ® GREENHECK FSD 231•OR EQUAL 3 HOUR HORIZONTAL COMBINATION FIRE/SMOKE GREENHECK CRD -2 OR EQUAL BACKDRAFT DAMPER HFSD © GREENHECK FSD 231 OR EQUAL SMOKE DAMPER BDD BAR L_^ 0 co s 0 o 0 z w O GREENHECK WO 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL BAROMETRIC RELIEF DAMPER (.05 OPNG.PRESSURE SHOWN) SD GREENHECK SMD 202 OR EQUAL MD. . MOTORIZED CONTROL DAMPER Q 2 M D 1- ,CC BUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER SHOP FABRICATED, W/ LOCKING QUADRANT GREENHECK VCD -23 OR EQUAL SMOKE CONTROL MOTORIZED DAMPER SCD ® GREENHECK SMD,301 OR EQUAL INTERLOCK WITH FIRE ALARM BY ELECTRICAL CONTRACTOR ACCESS DOOR AD > 18" x 18" MINIMUM THROUGH BUILDING CONSTRUCTION BY GENERAL CONTRACTOR GENERAL NOTES: • COMBINATION FIRE/SMOKE DAMPER REQUIREMENTS (UNLESS OTHERWISE NOTED): - CLASS II -165° FUSIBLE LINK . - FAIL-CLOSE, 120V ACTUATOR - ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR - INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR. FIRE DAMPER REQUIREMENTS: - BLADES OUT OF AIRSTREAM ON MEDIUM PRESSURE. DUCTS -165 F FUSIBLE LINK - CLASS 0 DRAWING SHEET INDEX NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM2.04 4TH FLOOR PLAN.- HVAC TM2.05 ROOF FLOOR PLAN - HVAC CONTACT LIST TITLE NAME COMPANY PHONE. NUMBER E -MAIL. PROJECT ENGINEER ACCOUNT EXECUTIVE SHEET METAL FOREMAN JARED SHEEKS STEVE FUNK LARRY HARBISON MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER 206- 768-3806 253-680-3172 206 - 768 -4294 jared.sheeks o(�,macmiller.com sfeveflink @macmiller.com. Iany.harbison @macmiller.cam SCOPE OF WORK UPS ROOM ROOFTOP UNIT ADDITION: PROVIDE AND INSTALL (1) 15 TON TRANE VOYAGER PACKAGED ROOFTOP AIR CONDITIONER. MOUNT UNIT ON FACTORY CURB. INSTALL ASSOCIATED SUPPLY AND RETURN DUCTWORK: WITH SUPPLY DUCTWORK TO TIE INTO EXISTING DUCTWORK. INSTALL (1) COUNTER- BALANCED BACKDRAFT DAMPER IN SUPPLY DROP FROM RTU. INSTALL (1) MOTORIZED CONTROL DAMPER IN EXISTING SUPPLY DUCTWORK TO. PREVENT BACKFLOW WHEN RTU-1 IS OPERATING. INTERLOCKING OF DAMPER WITH SUPPLY FAN OF RTU IS BY CONTROLS. CONTRACTOR. CONTROL OF ROOFTOP UNIT IS BY CONTROLS CONTRACTOR. HVAC GENERAL NOTES 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF "U" VALUE (BTUH /S.F. °F) = N/A WALL "U' VALUE (BTUH /S.F. °F) = N/A FLOOR "U" VALUE (BTUH /S.F. °F) = N/A GLASS "U" VALUE (BTUH/S.F.°F) = N/A GLASS SHADE COEFF. = N/A LIGHTING (WATTS /S.F.) = N/A MISC. EQUIP. (WATTS /S.F.) = N/A PEOPLE DENSITY (S.F. /PERSON) = N/A COOLING INDOOR DESIGN TEMP ( °F) = N/A COOLING OUTDOOR DESIGN TEMP ( °F) = N/A HEATING INDOOR DESIGN TEMP ( °F) = N/A HEATING OUTDOOR DESIGN TEMP ( °F) = N/A 2, THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMCIAND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6, DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED. WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2006 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIREISMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10.PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11.PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12.HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 13.HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH THE ELECTRICAL CONTRACTOR. 14.MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 15. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 16.OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 17.COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC 2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 18.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 19.FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL. DOORS MUST BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 20.DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS: 10 CFM /S.F. GRAVITY DAMPERS: 20 CFM/S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION). 21.OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 22.RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 23.PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. RECEIVED CITY OF TUKWILA LEGAL DESCRIPTION MAY 2.7 2010 APN # 0923049309 PERMIT CENTER LEGAL DESCRIPTION: BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89-16-35 E 100 FT TH S 24 -13 -53 E 567.42 FT TO POINT OF BEGINNING TH N 66 -35-01 E 120.47 FT TH N 20 -23-23 W 27.58 FT TH N 65 -32 -34 E 165 FT TO POINT ON WLY RIW LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1 -K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY R/W LINE S 24-27-26 E 110.84 FT TH FOLLOWING SAID WLY RNY LINE N 65- 32-34 E 10 FT TH FOLLOWING SAID WLY R/W LINE S 24 -27 -26 E 200 FT TH FOLLOWING SAID WLY RIW LINE N 65 -32 -34 E 20 FT TH FOLLOWING SAID WLY RAN LINE S 24-27 -26 El 26 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 65-32 -34 W THRU C/A OF 0 -12 -18 DISTANCE OF 10.03 FT TH S 65 -30 -25 W 199.33 FT TH N 2247 -01 W 21.44 FT TH S 63 -32-48 W 62.13 FT TH S 65 -46 -07 W 58.17 FT TH N 24 -13 -53 W 402.19 FT TO POINT OF BEGINNING LOT C OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0033 RECORDING NO 9810059013 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA VICINITY MAP NO SCALE SITE MAP • NO SCALE M10-P(1 0222) MacDonald Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 40 1T'�o� �P 3616 ? �'4, ''GIST ' . 84v �s`S- ONAL t‘G 1 EXPIRES: 07 -06 -10 1 _ _ _ _ - - - DEC14Z010 t _ c c I iY I . REVIEWED FOR CODE COMPLIANCE _ AP: QfV D - JUN 16 2010 _ kT Ue. - City of Tukwila - BUILDING DIVISIDIv - REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION RTU-1 ADDITION 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 0 co s 0 o 0 z w O SCHEDULES & NOTES - HVAC Q 2 M D 1- ,CC ENGINEER: LAST REVISED: J SHEEKS 09 -12 -08 CHECKED BY: DATE PLOTTED: B GEZON 09 -12 -08 CAD: ISSUE DATE: J SHEEKS DRAWING NUMBER: C -1490- 7386578 -00 -00 ISSUED FOR PERMIT SHEET NUMBER: TMO.O1 . t B 'aj D IE 1:� ICI isl 2 �3 NEW MOTORIZED DAMPER I GREENHECK VCD -23, FAIL OPEN 1 INTERLOCK WITH RTU SUPPLY FAN ( Y OTHERS) IS j t: I I 1.1 iI 41 ! { t I 1 IIl 11;1 62/18SL RETURN DUCT .1 I 1 11 UP TO ROOFTOP UNIT — —�I -- 'I, f1 '' �.. 4 'gyp Cju KOTOP�TSI ! �y 1 I n Q,UNTyR7BALANCED rOr IRAFT PAMPER RU' Kli CD6— I'I —• v t i CONNECT TO EXISTING DUCT WITH ANGLE TAP `; Irf \ 1 1 ri 0 f i 1 f 1. ti E % i 1 - �- ti(; : I WI: \ 1. ,€ -\ T 11111 \11 1 -I _ 1 '1' qi t4 , 1 / 1;i 11` 7 I !i k it L1 tt i !�,' ------ - --1% • 1— 1 =11 ; J, I~ 1 ACA1\1 r�i" EA t I t inn rifle-) i `'-_ I} • E 1 L -1 — — 1 11 ' 11 ill I1 • • II • 1 I I lI1 NEW CONTROL DAMPER co 0 0 N Friday, June 20, 09:32:09 AM, co-1 EXISTING SUPPLY DUCTWORK H ISOMETRIC VIEW — HVAC SCALE: 1/2" — RETURN DUCT UP TO ROOFTOP UNIT COUNTER — BALANCED BACKDRAFT DAMPER SUPPLY DUCT UP TO ROOFTOP UNIT L .....:...... Ls CO — i..c ATION ROOM 1 -1 4TH . FLOOR PLAN — HVAC SCALE: 1/8" = 1' -0" �o 11 l 11 1 111 III 111 i Ii I 1 1 1 1 (Ji t t I. I--- ji j t I i 1 t I 11 — _.r" C 1i E En DEC 14 2010 REVIEWED FOR CODE COMPLIANCE APPROVE JUN 1 6 2010 City of Tulwlla BUILDING DIVISION CITY R OF T ECE11i D_, l4IIILA MAY 2.72010 PERMIT CENTER (72) MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU . e,,:,:,,As,,,,,, ,, sy. , ..„, „ , 4, 361 • 41 °� .GZS w s9 -011A ' EXPIRES: 07 -06 -08 REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION RTU -1 ADDITION 12101 TUKWILA INTL BLVD TUKWILA, WA 4TH FLOOR PLAN — HVAC ENGINEER: LAST REVISED: J SHEEKS 09 -12 -08 CHECKED BY: DATE PLOTTED: B GEZON 09 -12 -08 CAD: ISSUE DATE: D IKERD DRAWING NUMBER: c- 1490 - 7386342 -00 ISSUED FOR PERMIT SHEET NUMBER: TM 2.04 N) CD a0 tom) cn 1- 0 0 z w 0 0 u_ D 1- z 0 U) w 0 Li —1 0 v) cip co w z w 0 0 co 0 0 N Thursday, September 11 03:43:49 PM, (-1-) \ 1.51 j j I 1 f.� = I•�- -� =— j ; IFi -1 j i I Li NEV CONDENSATE LINE I :; I; . \ � TO ROOF DRAIN i j -" \ 1Y2" PVC I _................... 0 • J 1:;•I I Jt aI i i it fI It I1 I EXIST.ING 3/4 "NPCW, CONNE I' i HUMIDIFIER (TYP.) /- Ea is i:; '7\ 1 l 1 // •, 1 / t 1 / 1 1/ it . — — - — 1 j AC-i-1 ( EXISTING) rai r 26"45 DN EXISTING) (EXISTING) (EXISTING) 42 "o (RELOCATED) AHU -3 (EXISTING) s 1 { I�. --\- 8"� DUpT UP THRUI ROOF \ TO RO F CAP REF -2) L.1.1 48"0 3 /4 "NPCW FROM BELOW ROOF } I i (EXISTING) EF- (EXISTING) ,r- ...z: • ;i k• i q 26"0 DN 1 h IJ i 1 { � —�1> Si � { „it , r iE I I EXISTING SCREENWALL - �{ NPCW ON THE ROOF. PROVID `� I HEAT TAPE, INSULATION WEATHER -PR00[ JACKET I 1 `(V 48 rr DII EXISTING ELECTRICAL \ PANELS ROOFTOP STEEL SUPPORT `!< STRUCTURE (SEE STRUCT DRAWINGS) 1 i 11 I 1 • EIK L- ROOF PLAN - HVAC SCALE: Y8» = 1 -0" •ow 0(12 °t DEC 14 21010 A� C REVIEWED FOR CODE COMPLIANCE APPRnVE JUN 16 2010 City of Tukwila BUILDING fIUISIfM cirvoicwiuA MAY 2.7 2010 PERMIT CENTER • C2) MacDonald - Miller FACILITY SOLUTIONS . 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206- 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU ,C} '• vAS8 �l� A" y.. 0 u ‘4. 3616 .crl Lt''',SWNA� EXPIRES: 07 -06 -08 —J REVISIONS: DATE DIGITAL FOREST DATA CENTER EXPANSION RTU -1 ADDITION 12101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA : ROOF PLAN - HVAC ENGINEER: LAST REVISED: J SHEEKS 09 -12 -08 CHECKED BY: DATE PLOTTED: B GEZON 09 -12 -08 CAD: ISSUE DATE: P MILLER DRAWING NUMBER: 0- 1490 - 7386342 -00 ISSUED FOR PERMIT SHEET NUMBER: TM2.05 C5 a fi 1-- i In 0 0 to co N 1- = (/) 0 0 z w 0 0 tt 0) 1- z 0 z w 0 0