HomeMy WebLinkAboutPermit M10-070 - DHSDEPARTMENT OF HOMELAND SECURITY 12500 TUKWILA INTERNATIONAL BL M10 -070 City oilI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 7340600602 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Project Name: DEPARTMENT OF HOMELAND SECURITY Permit Number: M10 -070 Issue Date: 06/10/2010 Permit Expires On: 12/07/2010 Owner: Name: INTERNATIONAL GATEWAY EAST LLC Address: 12201 TUKWILA INTL BLVD 4TH FLR , SEATTLE WA 98168 Contact Person: Name: TROY LOFTUS Address: 5005 3 AV S , SEATTLE WA 98134 Email: TROYL @MCKINSTRY.COM Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98134 Contractor License No: MCKINCL942DW Phone: 206 764 -1683 Phone: 206 762 -3311 Expiration Date: 03/16/2012 DESCRIPTION OF WORK: INSTALL FIVE (5) VAV BOXES (SEE EXPIRED PERMIT M09 -071) Value of Mechanical: $21,000.00 Type of Fire Protection: Permit Center Authorized Signature: Fees Collected: $398.81 International Mechanical Code Edition: 2009 Date: 't 0-1 v I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: 71/Z.0 Y Lc2tC 7 72S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 646/ o doc: IMC -4/10 M10 -070 Printed: 06 -10 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htv://www.ci.tulcwila.wa.us Parcel No.: 7340600602 Address: Suite No: Tenant: PERMIT CONDITIONS 12500 TUKWILA INTERNATIONAL BL TUKW DEPARTMENT OF HOMELAND SECURITY Permit Number: Status: Applied Date: Issue Date: M10 -070 ISSUED 05/28/2010 06/10/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and doc: Cond -10/06 M10-070 Printed: 06 -10 -2010 #2051) • • City of Tukwila Department of Connnumity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us 15: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -070 Printed: 06 -10 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. c� Signature: Print Name: c--7Z/z-› Date: 6 k/ D ordinances governing or local laws regulating doc: Cond -10!06 M10 -070 Printed: 06 -10 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us • Mechanical Permit No. 0 0 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 7340600602 Site Address: 12500 Tukwila International Blvd Suite Number: Floor: Tenant Name: Department of Homeland Security New Tenant: ❑ Yes ® ..No Property Owners Name: International Gateway East LLC Mailing Address: 12201 Tukwila International Blvd Tukwila WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Troy Loftus w/ McKinstry Co. Mailing Address: 5005 3rd Ave S Day Telephone: (206) 764 -1683 Seattle WA 98134 E -Mail Address: troyl @mckinstry.com City State Fax Number: (206) 716 -3441 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: McKinstry Co. Mailing Address: 5005 3rd Ave S Seattle WA 98134 Contact Person: Ali Sadigh E -Mail Address: alis @mckinstry.com Contractor Registration Number: MCKINCL942DW City Slate Zip Day Telephone: (206) 832 -8148 Fax Number: (206) 832 -8548 Expiration Date: 03/16/2012 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: McKinstry Co. Mailing Address: 5005 3rd Ave S Contact Person: Ali Sadigh Seattle WA 98134 E -Mail Address: alis @mckinstry.com H: \Applications\Potms- Applications On Line \2009 Apphcanons \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh City State Day Telephone: (206) 832 -8148 Fax Number: (206) 832 -8548 Zip Page 1 of 2 • Valuation of Project (contractor's bid price): $ 21,000 Scope of Work (please provide detailed information): Install five (5) VAV boxes. Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ 1,10 ,LceLto Fuel Type: Electric ® Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 5 Incinerator— Comm /Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN AUTHO' .EDAV Signature. i� • •iglif� Print Name: Renee Sanek Mailing Address: 5005 3rd Ave S Date: 05/28/2010 Day Telephone: (206) 832 -8242 Seattle WA 98134 City State Zip Date Application Accepted: VD Date Application Expires: (f Staff Initials: H:WpplicationsWorms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh ge 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 7340600602 Permit Number: M10 -070 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 05/28/2010 Applicant: DEPARTMENT OF HOMELAND SECURITY Issue Date: Receipt No.: R10 -01031 Payment Amount: $159.52 Initials: WER Payment Date: 06/10/2010 01:38 PM User ID: 1655 Balance: $0.00 Payee: TROY LOFTUS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 03577B ACCOUNT ITEM LIST: Description 159.52 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 159.52 Total: $159.52 PAYMENT RECEIVED doc: Receipt -06 Printed: 06 -10 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit { CITY OF TUKWILA BUILDING DIVISION p. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 M 10 —017d PERMIT NO. Project ki-cl j 1 ' j_ eikte4 Type of =n: �. /j /�(� ry Address: Date Called: Special Instructions: / Date Wanted: _ 5 7 J ajs, Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: prp krtct t(1 t■- 17A- e i A— ehze.c-A-7 Inspector: Date `(96 El $60.00 REINSPECTION FEE REQUIRED.'Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ra Y.. .. .� �4�!_Ill KVwnnA�RA1fOeA INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t/" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ,nor -ago Pro'ect: Iefirf7 - -0,64 {_ (A-•.,9 Typ of Inspection: k_0 6 �`f N �ie-A A dr ss: 125LId Tom, Date Called: Special Instructions: Date Wanted: Ca - 64 rQ a.rm.. Requester: Phone 0 (8(p 7 S0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 1 ❑ $60.00 REINSPECTION FEE REQUIRAt. Prior to inspection, fee must be • paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: (, -r4 - t� Receipt No.: Date: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKINILA FIRE DEPARTMENT 444 Arxicwer Park East. Tukwila. Wa. 98188 206 -575 -4407 Project: b, c i 0 Type of Inspection: ,1er( o J` j l'M it 7 ' '-'e f.'.'' ^� CIAO Address: !2-5 �:a ; r Suite 'M' . y0`, Con��t'af�cc /Persona / %%/ 7 ! s�:...�I G A /e a'�� i _ "> Special Instructions: Phone No.: I .,..:..0 i Occupancy Type:, Approved per applicable codes. inCorrections required prior to approval. COMMENTS; 1 Sprinklers: Are Alarm: Hood & Duct: Monitor: c... % Pre -Fire: .,1' Permits: Occupancy Type:, ;e7,... #1- ,,, d/4 -e ..- ... j V l4,4 ,T 4AS d ��yy i t E%G rl 5>/.4 t 44 le."( 5-5 ) j Needs Shift Inspection: 1 Sprinklers: Are Alarm: Hood & Duct: Monitor: c... % Pre -Fire: .,1' Permits: Occupancy Type:, Date :. lire.: $80.00 REIN: IEC ION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a relnspection. Word/Inspection Record Form.Doc 1/13/06 ()PERMIT COON COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -070 DATE: 05/28/10 PROJECT NAME: DEPARTMENT OF HOMELAND SECURITY SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: (off -(() Sutl'ding 'vision n Public Works Fire Preverftion Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IA. Comments: Incomplete DUE DATE: 06/03/10 Not Applicable Li Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Building Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/01/10 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Mckinstry Co Llc UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State Wa Expiration Date 3/16/2012 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JLLydig+ Mckinstry Llc Construction Contractor General Unused 4/13/2010 4/13/2012 Active WESTVI *121RF Westvent Inc Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN "372ND Mckinstry Co Construction Contractor General Unused 8/20/1963 1/2/2008 Relicensed Business Owner Information Name Role Effective Date Expiration Date Pedersen, Jamie D Agent 03/16/2006 Amount Allen, Dean C Partner /Member 03/16/2006 CP0399990301 Moore, Douglas J Partner /Member 03/16/2006 Allen, David E Partner /Member 03/16/2006 ZURICH AMERICAN INS CO Teplicky, Joseph Partner /Member 03/16/2006 Bond Information Page 1 of 1 Bond 1 Bond Company Name TRAVELERS CAS & SURETY CO Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 104702039 01/03/2006 Until Cancelled $12,000.00 03/16/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009 01/31/2011 $2,000,000.0012 /07/2009 2 ZURICH AMERICAN INS CO CP03999903 01/31/2008 01/31/2009 $2,000,000.00 01/31/2008 1 CHARTER OAK FIRE INS CO DTC052D7193C0F07 01/31/2006 01/31/2009 $1,000,000.00 01/08/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 06/10/2010 1 HVAC SYMBOLS & ABBREVIATIONS DUCTWORK ACCESSORIES ---1-> SUPPLY GRILLE -1 <-41- RETURN OR EXHAUST GRILLE --JET BACK DRAFT DAMPER �- VOLUME DAMPER WALL FIRE DAMPER FLOOR FIRE DAMPER WALL FIRE /SMOKE DAMPER FLOOR FIRE /SMOKE DAMPER -� - AD ZONE DAMPER --11 MOTORIZED DAMPER ACCESS DOORS ACOUSTICALLY LINED DUCT --6- ELEV. CHANGE RISE(R) DROP(D) -{>TRANSMON FLEXIBLE DUCT NWIMN GRILLE/REGISTER /DIFFUSER MI CEILING SUPPLY NR DIFFUSER (SHOWN WITH BLANK OFF) VCEILING RETURN, MUST V OR TRANSFER AR GRILLE E I Ei PERFORATED FLOOR TILE EQUIPMENT TAG EF3 -12 FLOEQUIP. # OR ## EQUIP. DESIGNATION ABBREVIATIONS ACT ACOUSTICAL CEIUNG TILE AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE CLG CEILING CFM CUBIC FEET PER MINUTE CORD CONDENSATE CRAC COMPUTER ROOM AIR CONDTIIONING CT COOLING TOWER DB DRY BULB (E) EXISTING EAT ENTERING AIR TEMP. ECG EGGCRATE GRILLE EF EXHAUST FAN EXH EXHAUST F /SD FIRE, SMOKE DAMPER FCU FAN COIL UNIT GRD GRILLE, REGISTER, DIFFUSER HC HEATING COIL HVAC HEATING, VENTILATION AND AIR CONDITIONING LAT LEAVING AIR TEMP. GENERAL SYMBOLS NEW WORK EXISTING WORK xxx DEMOLITION WORK DEMOLITION POINT CONNECTION POINT 12x12e FLAT OVAL DUCT • % _ .0 THERMOSTAT _ .0 SENSOR LD MOD MUA (N) NTS OA OBD QTY (R) RA RN SA SL SLSM TG TOD TOP UH UNO VAV VD VER VFD VSD WB •` - Ev CARBON MONOXIDE SENSOR - . MANUAL WALL SWITCH - DETAIL NUMBER -SHEET NUMBER \ REVISION NUMBER Q GENERAL NOTE VAV BOX TAG - FLOOR -BOX - EQUIPMENT TAG - PRIMARY CFM - FAN CFM 1 -23 S- C8 -09 -A 000 000 GRD TAG DT8-180 CFM I EACH � -SIZE TYPE CODE LINEAR DIFFUSER MOTOR OPERATED DAMPER MAKE OF AIR NEW NOT TO SCALE OVERALL; OUTSIDE AIR OPPOSED BLADE DAMPER QUANTITY RELOCATED RETURN AIR ROOF TOP UNIT SUPPLY AIR SOUND LINED SOUND LINED SHEET METAL TRANSFER GRILLE TOP OF DUCT TOP OF PIPE UNIT HEATER UNLESS NOTED OTHERWISE VARIABLE AIR VOLUME VOLUME DAMPER VERIFY VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE WET BULB SERIES VAV FAN TERMINAL SCHEDULE TAG BASIS OF DESIGN MANUF. MODEL 1 - UNIT SIZE PRIMARY CFM FAN CFM Min. CFM INLET SIZE DISCHARGE HEATER (B) ECM FAN MOTOR REMARKS PLENUM KW VOLTS /PHASE HP VOLTS /PHASE FT -AC2 -303 Envirotech model CFRQ -0811 650 650 240 8 0 14x12' - - 1/3 277/1 2,3,5,6 FT -AC2 -304 Envirotech model! CFRQ -1019 1120 1120 224 10 0 18x12" - - . 1/2 277/1 2,3,5,6 FT- AC2 -305 Envirotech model CFRQ -1019 1140 1140 224 10 0 18x12" - - 1/2 277/1 2,3,5,6 FT- AC2 -306 Envirotech model CFRQ -1019 1010 1010 210 10 a 18x12" 5 460 V/3 1/2 277/1 2,3,5,6 FT -AC2 -307 Envirotech model# CFRQ -1021 1080 1080 214 10 0 18"x12" 7 460 V/3 1/2 277/1 1,3,5,6 NOTES: 1) EXISTING VAV TERMINAL UNIT FROM BUILDING INVENTORY. 2) NEW VAV TERMINAL UNIT. 3) TRUNK DUCT SIZE SAME AS BOX INLET SIZE. 4) PROVIDE 2 STAGE HEATER ABOVE 6 KW. 5) PROVIDE FACTORY MOUNTING OF DAMPER ACTUATOR (ACTUATOR SUPPLIED BY OTHERS). 6) PROVIDE SOUND LINED SHEET METAL DISCHARGE. RETURN/EXHAUST/TRANSFER AIR GRILLE SCHEDULE TAG # 1 EC1 1 EC2 DEVICE TYPE EGGCRATE BASIS OF DESIGN - TITUS MODEL NO. 50F 50F RUNOUT SIZE (UNLESS NOTED OTHERWISE QN DRAWINGS) -- -- MAXIMUM CFM 600 1200 FACE SIZE j 24 X 12 24 X 24 MOUNTING (PROVIDE FRAME SUITABLE FOR sbEIUNG TYPE) T -BAR T -BAR MATERIAL ALUM ALUM PROVIDE PLENUM OR TRANSITION TO RECTANGULAR -- -- PROVIDE FRAME FOR DUCTED APPLICATION 24 X 24 NO NO PROVIDE OPPOSED BLADE DAMPER T- BAR NO NO PROVIDE STANDARD 126 WHITE FINISH YES YES DIFFUSER SCHEDULE TAG # DT6 DT8 DT1 0 DT1 2 BASIS OF DESIGN - TINS MODEL NO. MCD MCD MCD MCD RUNOUT SIZE (UNLESS NOTED OTHERWISE ON DRAWINGS) 6" RD. 8" RD. 10" RD. 12" RD. MAXIMUM CFM 110 220 350 500 NECK SIZE 6X6 8 X 8 10X10 12X12 FACE SIZE 24 X 24 24 X 24 24 X 24 24 X 24 MOUNTING (PROVIDE FRAME SUITABLE FOR CEILING TYPE) T- BAR T -BAR T -BAR T -BAR MATERIAL STEEL STEEL STEEL STEEL PROVIDE SHEET METAL OR DUCTBOARD PLENUM NO NO NO NO PROVIDE STANDARD #26 WHITE FINISH YES YES YES YES - , ►�- �-- i � I 'I! -, { r' rtR' i f �- ` �::- -! -.._ 1416 1111,ki t1; fry ' -:r• --t i,L '- - t(4f, lL - ; _ _. 4 .1 _ -- n -' LEGAL DESCRIPTION LOTS (PER BOUNDARY UNE ADJUSTMENT NO. L02 -057, AUDITOR'S FILE NO. 20030327900003, RECORDS OF KING COUNTY, WASHINGTON) THAT PORTION OF GOVERNMENT LOT 15 AND THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER, SECTION 10 AND THE SOUTHEAST QUARTER, SECTION 9, ALL IN TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: COMMENCING AT THE WEST ONE- QUARTER CORNER OF SAID SECTION 10; THENCE SOUTH 0116'02" WEST ALONG THE WEST UNE THEREOF A DISTANCE OF 107.22 FEET TO A POINT ON SAID UNE; THENCE LEAVING SAID UNE SOUTH 8733'12" EAST A DISTANCE OF 512.24 FEET; THENCE SOUTH 01'46'02' WEST A DISTANCE OF 402.93 FEET; THENCE NORTH 88'13'58" WEST A DISTANCE OF 616.22 FEET; THENCE SOUTH 32'09'15' EAST A DISTANCE OF 26.64 FEET; THENCE SOUTH 27O4'16* EAST A DISTANCE OF 220.58 FEET TO A POINT ON THE WEST UNE OF SAID GOVERNMENT LOT 15; THENCE LEAVING SAID WEST UNE SOUTH 20'30'45" EAST A DISTANCE OF 471.28 FEET; THENCE SOUTH 0r46'02' WEST A DISTANCE OF 433.06 FEET TO THE TRUE POINT OF BEGINNING; THENCE CONTINUING SOUTH 01'46'02" WEST A DISTANCE OF 129.92 FEET; THENCE SOUTH 88'13'56' EAST A DISTANCE OF 321.41 FEET; THENCE SOUTH 01'46'02' WEST A DISTANCE OF 367.67 FEET TO THE NORTH MARGIN OF SOUTH 126TH STREET; THENCE NORTH 89'18'50" WEST ALONG SAID MARGIN A DISTANCE OF 100.03 FEET; THENCE SOUTH 01'46'02' WEST A DISTANCE OF 10.00 FEET; THENCE NORTH 89'18'50" WEST A DISTANCE OF 20.00 FEET TO THE WESTERLY MARGIN OF 34TH AVENUE SOUTH; THENCE SOUTH 01'47'05" WEST ALONG SAID WEST MARGIN A DISTANCE OF 244.07 FEET TO THE SOUTHEAST CORNER OF LOT C OF BOUNDARY UNE ADJUSTMENT NO. 89- 6 -BIA, RECORDED UNDER KING COUNTY RECORDING NO. 8908161260; THENCE NORTH 88'48'42' WEST ALONG THE SOUTH LINE THEREOF A DISTANCE OF 277.34 FEET TO THE EAST MARGIN OF PRIMARY STATE HIGHWAY NO. 1, SR 99, PACIFIC HIGHWAY SOUTH, SAID POINT BEING ON A NON- RADIAL 1860.00 FOOT- RADIUS CURVE CONCAVE TO THE EAST AND FROM WHICH THE RADIUS POINT BEARS NORTH 73'28'18" EAST; THENCE NORTHERLY ALONG SAID MARGIN AND SAID CURVE AN ARC DISTANCE OF 134.53 FEET THROUGH A CENTRAL ANGLE OF 04'08'39' TO THE POINT OF TANGENCY; THENCE CONTINUING ALONG SAID EAST MARGIN NORTH 1723'03' WEST A DISTANCE OF 294.34 FEET TO AN ANGLE POINT ON SID MARGIN; THENCE CONTINUING ALONG SAID EAST MARGIN NORTH OT52'07" WEST A DISTANCE OF 229.45 FEET; THENCE LEAVING SAID EAST MARGIN SOUTH 8918'15" EAST A DISTANCE OF 252.04 FEET TO THE POINT OF BEGINNING. SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. EA s i 41 ;I r i t 1 il /k ; i ! i ( t \v k X " .I ! C rit - ' ) 12 "0 f"• 1 • . 1 U - DT1Q -28 app i0d is _� LE _.� ,�, 1-- T_ ` •_`' - T.. -> 11- f: 'EI'1"11' 1l� E �: LMLB�' }� r rE 9 mac -11 . . ►�: 4 o �tiF►�. �g rii_I'll'imi_mogitelLIA I/i� i l -I „ I I �� i II @ eater imia 1� II in jamoi , imapAmmEmecileiVirowaymurri ill 1111 Ia� \ 'I I 1 CORRIQOE ����=! sir m Mii tP-II11i i • r1 {�LoillEDEasLilll�_PR1 = I 11 f DTta 27/'1 I ■�■■ i i i i� ■Irk!'" w t' � � I �� ( _,�I�I� -11 1111101,11.1.1"Ali iu _ • r MINN Ill J� �_ , -iii .! itrusummiiiii , I��i� rt= -iii k ILL_ - =i�9� � BREA ' fnikilliWiiiirAPS . 41I ", exT o lme rrr 1 1m11��-1 I. !9-_,v g . _ _pal in 1 im OM II 1016l_ .---Iiim- II- weAL-Nomor i� " . IN� (0710 'M /t;l`1 DT6 -50 18X18 EC1 ME D) 40x30 OPENING ABOVE THE CEILING IN FULL HEIGHT WALL (BY GC) 1 3RD FLOOR HVAC PLAN _ SCALE: 1/8" = 1' -O' 739 CFM 4' 8' 16' LOCATION / VICINITY MAP GENERAL NOTES: 1. VERIFY LOCATIONS AND DIMENSIONS OF ALL EXISTING EQUIPMENT AND COORDINATE ALL WORK PRIOR TO START OF CONSTRUCTION. 2. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS: A. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE OWNER (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.4.3) B. PROVIDE TO THE OWNER ALL NECESSARY SYSTEM OPERATION AND MAINTENANCE MANUALS (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.4.2) C. BALANCE ALL HVAC SYSTEMS AND PROVIDE TO THE OWNER A WRITTEN BALANCING REPORT (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.2.1) D. EQUIPMENT /SYSTEMS TESTING SHALL BE PERFORMED IN ACCORDANCE WITH APPROVED PLANS (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1). E. TEST, CALIBRATE AND ADJUST ALL HVAC CONTROLS AND SEQUENCES OF OPERATION IN ACCORDANCE WM-I THE APPROVED PLANS (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.2), NECESSARY TESTS ARE IDENTIFIED IN 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1; PREPARE A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.5.1); PROVIDE TO THE OWNER A FINAL COMMISSIONING REPORT OF' lLs! PROCEDURES AND RESULTS (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 G ON STATE ENERGY CODE SECTION 1416.2.5.2 WASHINGTON . T ) 5. PERFORMANCE OF ALL NEW BUILDING MECHANICAL SYSTEMS WILL COMPLY WITH OR EXCEED THE MINIMUM REQUIREMENTS AS SET FORTH IN THE 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1410 GENERAL REQUIREMENTS. 6. MINIMUM VENTILATION QUANTMES WILL COMPLY WITH OR EXCEED THE 2006 SEATTLE SUPPLEMENT TO THE 2006 INTERNATIONAL MECHANICAL CODE. 7. ALL MOTORS WILL COMPLY WITH CHAPTER 15 OF THE 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SE7 8. ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED IN CHAPTER 14, TABLE 14-5 OF THE 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE DUCTWORK AND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS DRAWING SET 9. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. FILE COPY Permit No.M(d 670 Plln review approval is subject to errors and omissions. /.- ,oval of construction documents does not authorize , iolation of any adopted code or ordinance. Receipt o` .pproved Field Copy ar conditions is acknowledged: By_(--/ Date: (o /rz /I r) City Of Tukwila BUILDING DIVISION i REVISIONS No changes shall b e made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. M1O KEY PLAN NOT TO SCALE SEPARATE PERMIT REQUIRED FOR ❑ Mechanical Erbectrical numbing Gas Piping City of Tukwila Bl' '. f!NG DIVISION PROJECT: instry fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503- 331 -0234 www.mckinstry.com DEPARTMENT OF HOMELAND SECURITY TI SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD SEATTLE, WA 98168 REGISTRATION: ISSUES: 05/21/10 PERMIT SET REVIEWED FOR CODE COMPLIANCE_ APPROVED JUN 07 2010 S City of Tukwila BUILDING DIVISION RECEIV _U . CITYOFT K�IVILA MAY 2 8 2010 PERMIT CENTER NO. DATE DESCRIPTION McKINSTRY DMSION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING ALI SADIGH DOREL PURAVET ALI SADIGH 1745 05/07/2010 AS SHOWN SHEET TITLE: 3RD FLOOR HVAC PLAN SHEET NUMBER: M1.0