HomeMy WebLinkAboutPermit M10-070 - DHSDEPARTMENT OF
HOMELAND SECURITY
12500 TUKWILA
INTERNATIONAL BL
M10 -070
City oilI'ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
MECHANICAL PERMIT
Parcel No.: 7340600602
Address: 12500 TUKWILA INTERNATIONAL BL TUKW
Project Name: DEPARTMENT OF HOMELAND SECURITY
Permit Number: M10 -070
Issue Date: 06/10/2010
Permit Expires On: 12/07/2010
Owner:
Name: INTERNATIONAL GATEWAY EAST LLC
Address: 12201 TUKWILA INTL BLVD 4TH FLR , SEATTLE WA 98168
Contact Person:
Name: TROY LOFTUS
Address: 5005 3 AV S , SEATTLE WA 98134
Email: TROYL @MCKINSTRY.COM
Contractor:
Name: MCKINSTRY CO LLC
Address: PO BOX 24567 , SEATTLE WA 98134
Contractor License No: MCKINCL942DW
Phone: 206 764 -1683
Phone: 206 762 -3311
Expiration Date: 03/16/2012
DESCRIPTION OF WORK:
INSTALL FIVE (5) VAV BOXES (SEE EXPIRED PERMIT M09 -071)
Value of Mechanical: $21,000.00
Type of Fire Protection:
Permit Center Authorized Signature:
Fees Collected:
$398.81
International Mechanical Code Edition: 2009
Date: 't 0-1 v
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit.
Signature:
Print Name: 71/Z.0 Y Lc2tC 7 72S
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date: 646/ o
doc: IMC -4/10
M10 -070 Printed: 06 -10 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: htv://www.ci.tulcwila.wa.us
Parcel No.: 7340600602
Address:
Suite No:
Tenant:
PERMIT CONDITIONS
12500 TUKWILA INTERNATIONAL BL TUKW
DEPARTMENT OF HOMELAND SECURITY
Permit Number:
Status:
Applied Date:
Issue Date:
M10 -070
ISSUED
05/28/2010
06/10/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
11: ** *FIRE DEPARTMENT CONDITIONS * **
12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
doc: Cond -10/06
M10-070 Printed: 06 -10 -2010
#2051)
• •
City of Tukwila
Department of Connnumity Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
15: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page **
doc: Cond -10/06
M10 -070 Printed: 06 -10 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
c�
Signature:
Print Name:
c--7Z/z-›
Date: 6 k/ D
ordinances governing
or local laws regulating
doc: Cond -10!06 M10 -070
Printed: 06 -10 -2010
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
•
Mechanical Permit No. 0 0
Project No.
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: 7340600602
Site Address: 12500 Tukwila International Blvd Suite Number: Floor:
Tenant Name: Department of Homeland Security New Tenant: ❑ Yes ® ..No
Property Owners Name: International Gateway East LLC
Mailing Address: 12201 Tukwila International Blvd
Tukwila
WA 98168
City
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: Troy Loftus w/ McKinstry Co.
Mailing Address:
5005 3rd Ave S
Day Telephone: (206) 764 -1683
Seattle WA 98134
E -Mail Address: troyl @mckinstry.com
City State
Fax Number: (206) 716 -3441
Zip
MECHANICAL CONTRACTOR INFORMATION
Company Name: McKinstry Co.
Mailing Address: 5005 3rd Ave S
Seattle
WA 98134
Contact Person: Ali Sadigh
E -Mail Address: alis @mckinstry.com
Contractor Registration Number: MCKINCL942DW
City Slate Zip
Day Telephone: (206) 832 -8148
Fax Number: (206) 832 -8548
Expiration Date: 03/16/2012
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
E -Mail Address:
State
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name: McKinstry Co.
Mailing Address: 5005 3rd Ave S
Contact Person: Ali Sadigh
Seattle
WA 98134
E -Mail Address: alis @mckinstry.com
H: \Applications\Potms- Applications On Line \2009 Apphcanons \1 -2009 - Mechanical Permit Application.doc
Revised: 1 -2009
bh
City State
Day Telephone: (206) 832 -8148
Fax Number: (206) 832 -8548
Zip
Page 1 of 2
•
Valuation of Project (contractor's bid price): $ 21,000
Scope of Work (please provide detailed information): Install five (5) VAV boxes.
Use: Residential: New ❑ Replacement ❑
Commercial: New ® Replacement ❑
1,10 ,LceLto
Fuel Type: Electric ® Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000
BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000
BTU
Appliance Vent
Hood and Duct
Emergency Generator
50+ HP /1,750,000 BTU
Repair or addition to
Heat/Refrig /Cooling System
Incinerator — Domestic
Other Mechanical
Equipment
Air Handling Unit <10,000
CFM
5
Incinerator— Comm /Ind
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN AUTHO' .EDAV
Signature. i� • •iglif�
Print Name: Renee Sanek
Mailing Address: 5005 3rd Ave S
Date: 05/28/2010
Day Telephone: (206) 832 -8242
Seattle
WA 98134
City
State
Zip
Date Application Accepted: VD
Date Application Expires:
(f
Staff Initials:
H:WpplicationsWorms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc
Revised: 1 -2009
bh
ge 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
ParcelNo.: 7340600602 Permit Number: M10 -070
Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED
Suite No: Applied Date: 05/28/2010
Applicant: DEPARTMENT OF HOMELAND SECURITY Issue Date:
Receipt No.: R10 -01031
Payment Amount: $159.52
Initials: WER Payment Date: 06/10/2010 01:38 PM
User ID: 1655 Balance: $0.00
Payee: TROY LOFTUS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 03577B
ACCOUNT ITEM LIST:
Description
159.52
Account Code Current Pmts
MECHANICAL - NONRES
000.322.102.00.00 159.52
Total: $159.52
PAYMENT
RECEIVED
doc: Receipt -06 Printed: 06 -10 -2010
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
{
CITY OF TUKWILA BUILDING DIVISION p.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
M 10 —017d
PERMIT NO.
Project ki-cl j
1 ' j_
eikte4
Type of =n:
�.
/j
/�(�
ry
Address:
Date Called:
Special Instructions:
/
Date Wanted: _
5
7
J
ajs,
Requester:
Phone No:
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
prp krtct
t(1 t■- 17A- e
i A— ehze.c-A-7
Inspector:
Date `(96
El $60.00 REINSPECTION FEE REQUIRED.'Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
ra Y.. .. .� �4�!_Ill KVwnnA�RA1fOeA
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION t/"
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
,nor -ago
Pro'ect:
Iefirf7 - -0,64 {_ (A-•.,9
Typ of Inspection:
k_0 6 �`f N �ie-A
A dr ss:
125LId Tom,
Date Called:
Special Instructions:
Date Wanted: Ca - 64 rQ a.rm..
Requester:
Phone 0 (8(p 7 S0
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
1
❑ $60.00 REINSPECTION FEE REQUIRAt.
Prior to inspection, fee must be
• paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:
(, -r4 - t�
Receipt No.:
Date:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKINILA FIRE DEPARTMENT
444 Arxicwer Park East. Tukwila. Wa. 98188 206 -575 -4407
Project: b, c i 0
Type of Inspection:
,1er( o J` j l'M it 7
'
'-'e
f.'.'' ^� CIAO
Address: !2-5 �:a ; r
Suite 'M' . y0`,
Con��t'af�cc /Persona
/ %%/ 7 ! s�:...�I G A
/e a'��
i _ ">
Special Instructions:
Phone No.:
I .,..:..0 i
Occupancy Type:,
Approved per applicable codes.
inCorrections required prior to approval.
COMMENTS;
1
Sprinklers:
Are Alarm:
Hood & Duct:
Monitor: c...
%
Pre -Fire:
.,1'
Permits:
Occupancy Type:,
;e7,...
#1-
,,,
d/4 -e ..-
...
j
V l4,4
,T
4AS
d
��yy
i t
E%G
rl 5>/.4
t 44
le."( 5-5
)
j
Needs Shift Inspection:
1
Sprinklers:
Are Alarm:
Hood & Duct:
Monitor: c...
%
Pre -Fire:
.,1'
Permits:
Occupancy Type:,
Date :.
lire.:
$80.00 REIN: IEC ION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a relnspection.
Word/Inspection Record Form.Doc 1/13/06
()PERMIT COON COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -070 DATE: 05/28/10
PROJECT NAME: DEPARTMENT OF HOMELAND SECURITY
SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
(off -(()
Sutl'ding 'vision
n
Public Works
Fire Preverftion
Structural
Planning Division
❑ Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete IA.
Comments:
Incomplete
DUE DATE: 06/03/10
Not Applicable Li
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Building
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required n
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 07/01/10
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Pr ter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name Mckinstry Co Llc UBI No. 602569922
Phone 2067623311 Status Active
Address Po Box 24567 License No. MCKINCL942DW
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 3/16/2006
State Wa Expiration Date 3/16/2012
Zip 98134 Suspend Date
County King Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
LYDIGML901JLLydig+
Mckinstry Llc
Construction
Contractor
General
Unused
4/13/2010
4/13/2012
Active
WESTVI *121RF
Westvent Inc
Construction
Contractor
General
Unused
12/6/1988
9/1/1994
Archived
MCKIN "372ND
Mckinstry Co
Construction
Contractor
General
Unused
8/20/1963
1/2/2008
Relicensed
Business Owner Information
Name
Role
Effective Date
Expiration Date
Pedersen, Jamie D
Agent
03/16/2006
Amount
Allen, Dean C
Partner /Member
03/16/2006
CP0399990301
Moore, Douglas J
Partner /Member
03/16/2006
Allen, David E
Partner /Member
03/16/2006
ZURICH
AMERICAN INS
CO
Teplicky, Joseph
Partner /Member
03/16/2006
Bond Information
Page 1 of 1
Bond
1
Bond Company Name
TRAVELERS CAS &
SURETY CO
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
104702039
01/03/2006
Until Cancelled
$12,000.00
03/16/2006
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
ZURICH
AMERICAN INS
CO
CP0399990301
01/31/2009
01/31/2011
$2,000,000.0012
/07/2009
2
ZURICH
AMERICAN INS
CO
CP03999903
01/31/2008
01/31/2009
$2,000,000.00
01/31/2008
1
CHARTER OAK
FIRE INS CO
DTC052D7193C0F07
01/31/2006
01/31/2009
$1,000,000.00
01/08/2008
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
06/10/2010
1
HVAC SYMBOLS & ABBREVIATIONS
DUCTWORK ACCESSORIES
---1-> SUPPLY GRILLE
-1 <-41- RETURN OR EXHAUST GRILLE
--JET BACK DRAFT DAMPER
�- VOLUME DAMPER
WALL FIRE DAMPER
FLOOR FIRE DAMPER
WALL FIRE /SMOKE DAMPER
FLOOR FIRE /SMOKE DAMPER
-� - AD ZONE DAMPER
--11 MOTORIZED DAMPER
ACCESS DOORS
ACOUSTICALLY LINED DUCT
--6- ELEV. CHANGE RISE(R) DROP(D)
-{>TRANSMON
FLEXIBLE DUCT
NWIMN
GRILLE/REGISTER /DIFFUSER
MI CEILING SUPPLY NR DIFFUSER
(SHOWN WITH BLANK OFF)
VCEILING RETURN, MUST
V OR TRANSFER AR GRILLE
E I Ei PERFORATED FLOOR TILE
EQUIPMENT TAG
EF3 -12
FLOEQUIP. #
OR ##
EQUIP. DESIGNATION
ABBREVIATIONS
ACT ACOUSTICAL CEIUNG TILE
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
BDD BACKDRAFT DAMPER
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
CLG CEILING
CFM CUBIC FEET PER MINUTE
CORD CONDENSATE
CRAC COMPUTER ROOM AIR
CONDTIIONING
CT COOLING TOWER
DB DRY BULB
(E) EXISTING
EAT ENTERING AIR TEMP.
ECG EGGCRATE GRILLE
EF EXHAUST FAN
EXH EXHAUST
F /SD FIRE, SMOKE DAMPER
FCU FAN COIL UNIT
GRD GRILLE, REGISTER, DIFFUSER
HC HEATING COIL
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
LAT LEAVING AIR TEMP.
GENERAL SYMBOLS
NEW WORK
EXISTING WORK
xxx DEMOLITION WORK
DEMOLITION POINT
CONNECTION POINT
12x12e FLAT OVAL DUCT
• % _
.0 THERMOSTAT
_ .0 SENSOR
LD
MOD
MUA
(N)
NTS
OA
OBD
QTY
(R)
RA
RN
SA
SL
SLSM
TG
TOD
TOP
UH
UNO
VAV
VD
VER
VFD
VSD
WB
•` - Ev CARBON MONOXIDE
SENSOR
- . MANUAL WALL
SWITCH
- DETAIL NUMBER
-SHEET NUMBER
\ REVISION NUMBER
Q GENERAL NOTE
VAV BOX TAG
- FLOOR -BOX
- EQUIPMENT TAG
- PRIMARY CFM
- FAN CFM
1 -23
S- C8 -09 -A
000
000
GRD TAG
DT8-180 CFM
I EACH
� -SIZE
TYPE CODE
LINEAR DIFFUSER
MOTOR OPERATED DAMPER
MAKE OF AIR
NEW
NOT TO SCALE
OVERALL; OUTSIDE AIR
OPPOSED BLADE DAMPER
QUANTITY
RELOCATED
RETURN AIR
ROOF TOP UNIT
SUPPLY AIR
SOUND LINED
SOUND LINED SHEET METAL
TRANSFER GRILLE
TOP OF DUCT
TOP OF PIPE
UNIT HEATER
UNLESS NOTED OTHERWISE
VARIABLE AIR VOLUME
VOLUME DAMPER
VERIFY
VARIABLE FREQUENCY DRIVE
VARIABLE SPEED DRIVE
WET BULB
SERIES VAV FAN TERMINAL SCHEDULE
TAG
BASIS OF DESIGN
MANUF. MODEL 1 - UNIT SIZE
PRIMARY
CFM
FAN
CFM
Min.
CFM
INLET
SIZE
DISCHARGE
HEATER (B)
ECM FAN MOTOR
REMARKS
PLENUM
KW
VOLTS /PHASE
HP
VOLTS /PHASE
FT -AC2 -303
Envirotech model CFRQ -0811
650
650
240
8 0
14x12'
-
-
1/3
277/1
2,3,5,6
FT -AC2 -304
Envirotech model! CFRQ -1019
1120
1120
224
10 0
18x12"
-
- .
1/2
277/1
2,3,5,6
FT- AC2 -305
Envirotech model CFRQ -1019
1140
1140
224
10 0
18x12"
-
-
1/2
277/1
2,3,5,6
FT- AC2 -306
Envirotech model CFRQ -1019
1010
1010
210
10 a
18x12"
5
460 V/3
1/2
277/1
2,3,5,6
FT -AC2 -307
Envirotech model# CFRQ -1021
1080
1080
214
10 0
18"x12"
7
460 V/3
1/2
277/1
1,3,5,6
NOTES:
1) EXISTING VAV TERMINAL UNIT FROM BUILDING INVENTORY.
2) NEW VAV TERMINAL UNIT.
3) TRUNK DUCT SIZE SAME AS BOX INLET SIZE.
4) PROVIDE 2 STAGE HEATER ABOVE 6 KW.
5) PROVIDE FACTORY MOUNTING OF DAMPER ACTUATOR (ACTUATOR SUPPLIED BY OTHERS).
6) PROVIDE SOUND LINED SHEET METAL DISCHARGE.
RETURN/EXHAUST/TRANSFER AIR GRILLE SCHEDULE
TAG # 1
EC1 1
EC2
DEVICE TYPE
EGGCRATE
BASIS OF DESIGN - TITUS MODEL NO.
50F
50F
RUNOUT SIZE (UNLESS NOTED OTHERWISE QN DRAWINGS)
--
--
MAXIMUM CFM
600
1200
FACE SIZE j
24 X 12
24 X 24
MOUNTING (PROVIDE FRAME SUITABLE FOR sbEIUNG TYPE)
T -BAR
T -BAR
MATERIAL
ALUM
ALUM
PROVIDE PLENUM OR TRANSITION TO RECTANGULAR
--
--
PROVIDE FRAME FOR DUCTED APPLICATION
24 X 24
NO
NO
PROVIDE OPPOSED BLADE DAMPER
T- BAR
NO
NO
PROVIDE STANDARD 126 WHITE FINISH
YES
YES
DIFFUSER SCHEDULE
TAG #
DT6
DT8
DT1 0
DT1 2
BASIS OF DESIGN - TINS MODEL NO.
MCD
MCD
MCD
MCD
RUNOUT SIZE (UNLESS NOTED OTHERWISE ON DRAWINGS)
6" RD.
8" RD.
10" RD.
12" RD.
MAXIMUM CFM
110
220
350
500
NECK SIZE
6X6
8 X 8
10X10
12X12
FACE SIZE
24 X 24
24 X 24
24 X 24
24 X 24
MOUNTING (PROVIDE FRAME SUITABLE FOR CEILING TYPE)
T- BAR
T -BAR
T -BAR
T -BAR
MATERIAL
STEEL
STEEL
STEEL
STEEL
PROVIDE SHEET METAL OR DUCTBOARD PLENUM
NO
NO
NO
NO
PROVIDE STANDARD #26 WHITE FINISH
YES
YES
YES
YES
- , ►�- �--
i � I
'I!
-, { r' rtR' i
f
�- ` �::- -! -.._ 1416
1111,ki t1;
fry ' -:r•
--t i,L '-
- t(4f, lL
- ; _ _. 4 .1 _ --
n -'
LEGAL DESCRIPTION
LOTS (PER BOUNDARY UNE ADJUSTMENT NO. L02 -057, AUDITOR'S FILE NO.
20030327900003, RECORDS OF KING COUNTY, WASHINGTON)
THAT PORTION OF GOVERNMENT LOT 15 AND THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER, SECTION 10 AND THE SOUTHEAST QUARTER, SECTION 9, ALL IN
TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS:
COMMENCING AT THE WEST ONE- QUARTER CORNER OF SAID SECTION 10;
THENCE SOUTH 0116'02" WEST ALONG THE WEST UNE THEREOF A DISTANCE OF 107.22 FEET TO A POINT ON SAID UNE;
THENCE LEAVING SAID UNE SOUTH 8733'12" EAST A DISTANCE OF 512.24 FEET;
THENCE SOUTH 01'46'02' WEST A DISTANCE OF 402.93 FEET;
THENCE NORTH 88'13'58" WEST A DISTANCE OF 616.22 FEET;
THENCE SOUTH 32'09'15' EAST A DISTANCE OF 26.64 FEET;
THENCE SOUTH 27O4'16* EAST A DISTANCE OF 220.58 FEET TO A POINT ON THE WEST UNE OF SAID GOVERNMENT LOT 15;
THENCE LEAVING SAID WEST UNE SOUTH 20'30'45" EAST A DISTANCE OF 471.28 FEET;
THENCE SOUTH 0r46'02' WEST A DISTANCE OF 433.06 FEET TO THE TRUE POINT OF BEGINNING;
THENCE CONTINUING SOUTH 01'46'02" WEST A DISTANCE OF 129.92 FEET;
THENCE SOUTH 88'13'56' EAST A DISTANCE OF 321.41 FEET;
THENCE SOUTH 01'46'02' WEST A DISTANCE OF 367.67 FEET TO THE NORTH MARGIN OF SOUTH 126TH STREET;
THENCE NORTH 89'18'50" WEST ALONG SAID MARGIN A DISTANCE OF 100.03 FEET;
THENCE SOUTH 01'46'02' WEST A DISTANCE OF 10.00 FEET;
THENCE NORTH 89'18'50" WEST A DISTANCE OF 20.00 FEET TO THE WESTERLY MARGIN OF 34TH AVENUE SOUTH;
THENCE SOUTH 01'47'05" WEST ALONG SAID WEST MARGIN A DISTANCE OF 244.07 FEET TO THE SOUTHEAST CORNER OF LOT C OF BOUNDARY UNE ADJUSTMENT NO.
89- 6 -BIA, RECORDED UNDER KING COUNTY RECORDING NO. 8908161260;
THENCE NORTH 88'48'42' WEST ALONG THE SOUTH LINE THEREOF A DISTANCE OF 277.34 FEET TO THE EAST MARGIN OF PRIMARY STATE HIGHWAY NO. 1, SR 99, PACIFIC
HIGHWAY SOUTH, SAID POINT BEING ON A NON- RADIAL 1860.00 FOOT- RADIUS CURVE CONCAVE TO THE EAST AND FROM WHICH THE RADIUS POINT BEARS NORTH
73'28'18" EAST;
THENCE NORTHERLY ALONG SAID MARGIN AND SAID CURVE AN ARC DISTANCE OF 134.53 FEET THROUGH A CENTRAL ANGLE OF 04'08'39' TO THE POINT OF TANGENCY;
THENCE CONTINUING ALONG SAID EAST MARGIN NORTH 1723'03' WEST A DISTANCE OF 294.34 FEET TO AN ANGLE POINT ON SID MARGIN;
THENCE CONTINUING ALONG SAID EAST MARGIN NORTH OT52'07" WEST A DISTANCE OF 229.45 FEET;
THENCE LEAVING SAID EAST MARGIN SOUTH 8918'15" EAST A DISTANCE OF 252.04 FEET TO THE POINT OF BEGINNING.
SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON.
EA s i 41 ;I r i t 1
il /k ; i !
i ( t \v
k X
" .I ! C
rit
-
' )
12 "0
f"•
1
• . 1 U - DT1Q -28 app i0d is _� LE
_.� ,�, 1-- T_ ` •_`' - T.. -> 11- f: 'EI'1"11' 1l� E
�: LMLB�'
}� r
rE
9 mac -11 . . ►�: 4 o �tiF►�. �g rii_I'll'imi_mogitelLIA I/i� i l -I „ I I
�� i II @ eater imia 1�
II in
jamoi , imapAmmEmecileiVirowaymurri
ill
1111 Ia� \ 'I I 1 CORRIQOE
����=! sir m
Mii tP-II11i i •
r1 {�LoillEDEasLilll�_PR1 = I 11
f DTta 27/'1 I
■�■■ i i i i�
■Irk!'" w t' � � I �� ( _,�I�I� -11 1111101,11.1.1"Ali
iu _ • r MINN Ill
J� �_ , -iii .!
itrusummiiiii ,
I��i�
rt= -iii k ILL_ - =i�9� � BREA ' fnikilliWiiiirAPS
. 41I ", exT o lme rrr 1
1m11��-1 I. !9-_,v
g . _ _pal in 1
im OM II 1016l_ .---Iiim- II- weAL-Nomor
i� " .
IN� (0710 'M /t;l`1
DT6 -50
18X18
EC1
ME
D)
40x30 OPENING ABOVE
THE CEILING IN FULL
HEIGHT WALL (BY GC)
1 3RD FLOOR HVAC PLAN
_ SCALE: 1/8" = 1' -O'
739 CFM
4'
8'
16'
LOCATION / VICINITY MAP
GENERAL NOTES:
1. VERIFY LOCATIONS AND DIMENSIONS OF ALL EXISTING EQUIPMENT AND COORDINATE
ALL WORK PRIOR TO START OF CONSTRUCTION.
2. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS:
A. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE OWNER (PER
2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE
SECTION 1416.2.4.3)
B. PROVIDE TO THE OWNER ALL NECESSARY SYSTEM OPERATION AND MAINTENANCE
MANUALS (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE
ENERGY CODE SECTION 1416.2.4.2)
C. BALANCE ALL HVAC SYSTEMS AND PROVIDE TO THE OWNER A WRITTEN BALANCING
REPORT (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE
ENERGY CODE SECTION 1416.2.2.1)
D. EQUIPMENT /SYSTEMS TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
APPROVED PLANS (PER 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON
STATE ENERGY CODE SECTION 1416.2.3.1).
E. TEST, CALIBRATE AND ADJUST ALL HVAC CONTROLS AND SEQUENCES OF
OPERATION IN ACCORDANCE WM-I THE APPROVED PLANS (PER 2006 SEATTLE
SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION
1416.2.3.2), NECESSARY TESTS ARE IDENTIFIED IN 2006 SEATTLE SUPPLEMENT TO
THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1; PREPARE A
PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS PRIOR
TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY (PER 2006 SEATTLE
SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION
1416.2.5.1); PROVIDE TO THE OWNER A FINAL COMMISSIONING REPORT OF' lLs!
PROCEDURES AND RESULTS (PER 2006 SEATTLE SUPPLEMENT TO THE 2006
G ON STATE ENERGY CODE SECTION 1416.2.5.2
WASHINGTON . T )
5. PERFORMANCE OF ALL NEW BUILDING MECHANICAL SYSTEMS WILL COMPLY WITH OR
EXCEED THE MINIMUM REQUIREMENTS AS SET FORTH IN THE 2006 SEATTLE
SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1410
GENERAL REQUIREMENTS.
6. MINIMUM VENTILATION QUANTMES WILL COMPLY WITH OR EXCEED THE 2006
SEATTLE SUPPLEMENT TO THE 2006 INTERNATIONAL MECHANICAL CODE.
7. ALL MOTORS WILL COMPLY WITH CHAPTER 15 OF THE 2006 SEATTLE SUPPLEMENT
TO THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE
EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SE7
8. ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED IN CHAPTER 14, TABLE 14-5
OF THE 2006 SEATTLE SUPPLEMENT TO THE 2006 WASHINGTON STATE ENERGY
CODE. FOR ADDITIONAL DETAILS, SEE DUCTWORK AND PIPING SPECIFICATION
MATRICES CONTAINED WITHIN THIS DRAWING SET
9. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO
CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS.
FILE COPY
Permit No.M(d 670
Plln review approval is subject to errors and omissions.
/.- ,oval of construction documents does not authorize
, iolation of any adopted code or ordinance. Receipt
o` .pproved Field Copy ar conditions is acknowledged:
By_(--/
Date: (o /rz /I r)
City Of Tukwila
BUILDING DIVISION
i
REVISIONS
No changes shall b e made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
M1O
KEY PLAN
NOT TO SCALE
SEPARATE
PERMIT
REQUIRED FOR
❑ Mechanical
Erbectrical
numbing
Gas Piping
City of Tukwila
Bl' '. f!NG DIVISION
PROJECT:
instry
fe Of Your Building
SEATTLE:
5005 3RD AVENUE S
PO BOX 24567
SEATTLE, WA 98124
1- 800 - 669 -6223
PORTLAND:
16790 NE MASON ST
PORTLAND, OR 97230
503- 331 -0234
www.mckinstry.com
DEPARTMENT
OF HOMELAND
SECURITY TI
SEATTLE DISTRICT OFFICE
12500 TUKWILA INTERNATIONAL BLVD
SEATTLE, WA 98168
REGISTRATION:
ISSUES:
05/21/10 PERMIT SET
REVIEWED FOR
CODE COMPLIANCE_
APPROVED
JUN 07 2010
S
City of Tukwila
BUILDING DIVISION
RECEIV _U .
CITYOFT K�IVILA
MAY 2 8 2010
PERMIT CENTER
NO. DATE DESCRIPTION
McKINSTRY DMSION:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
JOB NUMBER:
DATE:
SCALE:
ENGINEERING
ALI SADIGH
DOREL PURAVET
ALI SADIGH
1745
05/07/2010
AS SHOWN
SHEET TITLE:
3RD FLOOR
HVAC PLAN
SHEET NUMBER:
M1.0