Loading...
HomeMy WebLinkAboutPermit M10-081 - WOWRACK TECHNOLOGIESWOWRACK 12201 TUKWILA INTERNATIONAL BL M10 -081 City JP-Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 0923049120 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Project Name: WOWRACK TECHNOLOGIES Permit Number: M10 -081 Issue Date: 07/09/2010 Permit Expires On: 01/05/2011 Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 Contact Person: Name: JIMMY PANDRA Phone: 206 890 -8080 Address: 12201 TUKWILA INTERNATIONAL BL, STE 110 , TUKWILA WA 98168 Email: JIM @WOWRACK.COM Contractor: Name: VITAL MECHANICAL SERVICE INC Address: 14630 SE 213 ST , KENT WA 98042 Contractor License No: VITALMS964MM Phone: Expiration Date: 08/08/2010 DESCRIPTION OF WORK: INSTALL () CRAC UNIT WITH AIRSIDE ECONOMIZER, (2) EXHAUST FANS, AND ABOUT 30 FEET OF DUCT. Value of Mechanical: $70,000.00 Type of Fire Protection: Permit Center Authorized Signature: Fees Collected: $960.06 International Mechanical Code Edition: 2009 Date: -7 -9 - l 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: - //i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -081 Printed: 07 -09 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 0923049120 Address: Suite No: Tenant: PERMIT CONDITIONS 12201 TUKWILA INTERNATIONAL BL TUKW WOWRACK TECHNOLOGIES Permit Number: Status: Applied Date: Issue Date: M10 -081 ISSUED 06/21/2010 07/09/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M10 -081 Printed: 07 -09 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -081 Printed: 07 -09 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: 770 / ordinances governing or local laws regulating doc: Cond -10/06 M10 -081 Printed: 07 -09 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. Project No. k%'0' (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION �j King Co Assessor's Tax No.: Site Address: (ZZ' 0 T'-"c& ( I i 1� p I (fa akfg r Suite Number: Tenant Name: w©tAJ +e C(^txOl0cjies ( (v)C Property Owners Name: 5e10e c) ( vi- Q©c e+ -,0111 Mailing Address: 11-10 ( 'tu E_ i.,:1 (o` (A' f g, I tid i i (o New Te (� ® Floor: nant: ....Yes ❑..No GA6 98 (68 City State Zip CONTACT PERSON Who do we contact when your permit is ready to be issued Name: Mailing Address: 12-2-01 (' t a /wA 14_1(0 i N'l ice, 9 avl (cr■. E -Mail Address: Day Telephone: IN -- 890— 0- a 6 U 0 tAhi- 98168 City State Zip Fax Number: MECHANICAL CONTRACTOR INFORMATION Company Name: 1/ + e , A € ( A C c 5.a r V i L e Mailing Address: 13 0 4) 5£ 7--1-1M14 5T ,(© ( VQ A-t 339 031 p , City State/ Zip Contact Person: k-� V t I^ A1 MO I / Day Telephone: ZS 3 6 30 - 6 °J 3 3 E -Mail Address: K-eU l v\ a' i' (kW me c 41,0 ca(. U' ~ Fax Number: 2S 3f" 66 3 O- Contractor Registration Number: V i k, V A j 5 6 wl t"'l Expiration Date: UJ( 872 d( 0 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: E -1vv'4 56cA7-1Aeer;A 6Jl on �2 Se eS D 2 X/e- Contact Person: D " H 1 U kI `b \A1/111 VY1t E -Mail Address: H.\ApplicationsTorms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised' 1 -2009 bh ,I /1 c. B6iV115C1 � 151014e ( 081(0 City / State Zi Day Telephone: 7-0C � (4� Fax Number: -66 8442, z — 691 Page 1 of 2 Valuation of Project (contractor's bid price): $ ` p Scope of Work (please provide detailed information): ( �S l L C'o c Vv ft (.)-A 'h.. ` S le e ol,A0mt-Tke( avt) Z C( ■Ao0U 30 ,CP vlr �tuc Use: Residential: New Commercial: New Fuel Type: Electric Replacement Replacement Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM ' Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat , HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: wk Qavjr6N, t �v � W, �� (ANA- 19V Olt° Day Telephone: Co. City Date: 4'2 ( 2,010 2o6— g10 —gaPO State Zip I Date Application Accepted: ic D Il ( 21 1 i 0 Date Application Expires: 12 u ( 110 Staff Initials: I H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0923049120 Permit Number: M10 -081 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 06/21/2010 Applicant: WOW TECHNOLOGIES Issue Date: Receipt No.: R10 -01103 Payment Amount: $192.01 Initials: JEM Payment Date: 06/21/2010 10:46 AM User ID: 1165 Balance: $0.00 Payee: JIMMY PANDRA, WOW TECHNOLOGIES INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 086528 ACCOUNT ITEM LIST: Description 192.01 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 192.01 Total: $192.01 PAYMENT RECEIVED doc: Receipt -06 Printed: 06 -21 -2010 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT ParcelNo.: 0923049120 Permit Number: M10 -081 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 06/21/2010 Applicant: WOW TECHNOLOGIES Issue Date: Receipt No.: R10 -01104 Initials: User ID: Payee: JEM 1165 Payment Amount: $768.05 Payment Date: 06/21/2010 10:48 AM Balance: $0.00 JIMMY PANDRA, WOW TECHNOLOGIES INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 041182 ACCOUNT ITEM LIST: Description 768.05 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 768.05 Total: $768.05 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -21 -2010 • INSPECTION RECORD copy with permit INSP.Zw---Betaio--a I'IJ /Q D6 / PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431- 3670 .. Permit Inspection Request Line (206) 431 -2451 Project: 61/0609 idex 7e'1 Type of Inspection: .A1.9i Address: /2,1,a/ Tom _L Date Called: Special Instructions: • r f.10 ' Date Wanted: a.m. Requester: - Phone NO: ,..— O r -,.2.6 5-"' /l' Q Approved•per applicable codes. ° Corrections required prior to approval. • CO ENTS: 9 f El SPECTION FEE REQUIRED. Prior to nVkt inspection. fee must be • . a' • at 6300 Southcenter Blvd.. Suite 100. all to schedule reinspection. } INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT ND. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila. WA 98188 206 431 -3670 Permit Inspection Request Line (206) 431 -2451 ' w Project: l..e...I✓ ZAJ1QfC /1 --fro? 1 • Type of Inspection: /� 6- )/Ati- r i Address: j 2-24 J 'T .R Date Called: Special Instructions: Date Wanted: ---2 /_ /6 Requester: Phone No: / Approved per applicable codes. Corrections required prior to approval. COM ENTS: sp ;,ctor: Date: 9 / •/O ECTION FEE REQUIRE Prior to/ext inspection. fee must be at'6300 Southcenter Blvd., ' uite 100. Call to schedule rejnspection. • • INSPECTION RECORD Retain a copy with permit NSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: G. it :12) fi.a, Type of Inspection: Fire Alarm: 4 Hood & Duct: Address: 17. -2.. c� 1 Suite #. i 1 0 contact Person: f%' icy, \f rls■ c -4..- .:-. o* = Special Instructions: Phone No.: Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: 4 Hood & Duct: Monitor: (3i, ut oyeS , ev Pre -Fire: Permits: Occupancy Type: (r2 A _ - 1 4 .. , >Q +. z /4--,,,4 . c y. r, , cr-L ....h.^ (/ c. G, W, i , ( t - ltt $; j . ,,,, , ie t et_rkc L/Q S 'f -LA . t z iaj 1 ycszf. ire .�.QA 1.y i ( A- A ] ' vt e..,L ✓L .. ,v, a.,. j z"'r t ,y- , ' r , Needs Shift Inspection: Sprinklers: Fire Alarm: 4 Hood & Duct: Monitor: (3i, ut oyeS , ev Pre -Fire: Permits: Occupancy Type: H $80.00 REI$SPECTI ©N FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. o• • REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. Prr7 . 1:':-!sons will require a new plan submittal » de &k tional plen review fees. S MECHANICAL SPECIFICAT OW General 1. All work to conform to 2006 International Med+anical „ode, 2006 Uniform Plumbing Code, City of Tukwila Building Codes, and 2006 Washington State Energy Code. 2. Take out end pay far all permits. and fee, re/Lured This also ■nduile3 completion of required cover sheets and WSEC forms. 3 Lied w+f 'dent journeyman workmen 0ns ,:ompetrrn. supervisor, in the execution of this work to ensure proper and adequate Installation throughout. 4. Cutting. Patching. and Demolition: B. Do all cutting, patching and doo'ol,t:on reguir.d to Install materials and systonlo epecitled and show on the dravmgS b. Cutting shall be done in a neat and wortrnan !.: e manner limiting scope to only that which is ne,:e7Sary to accompllsn U'r now work Remove all cut material from ,its. Patch to match casting c. Do no cutting or dulling of struet+.ra1 nvmhrr; or slabs without permission of the Owner. d. Tate precautions to protect bt.Idn,g sortents and occupants and repot,- W like -new condition or repla,.e 11 directed, al: damage to bul:dmg and their contents h. The Contra :tor shall visit alto rro, is 3uh:nitt,ng a bid and note all .ond,Lionu affecting his work No extras ,NII be allowed for c,lorhnmUOn or relocation of existing conditions not ahaw, on the drawmg3 6. Provide all rocks, stand, and ai.hitient e for rec: iuni;ol equipment and di:ctm, t as regwrell. Supports for piping sn511 isolate F re frprl oupr.•rt 7. The 0/1000145 are generally diagrarnmat,c C,mr!ete de'ait3 of the bwLiing which affect the installation may not be shown, Cont r act,- to Prom), cornplste Hvri syc ton, as shown on The d-av/ng.. Exact location of el. .mn to re ,er -led in the field. 8. Corn rector shall be responsible fir ,font ooe; '5,.07,1 by t+.clr t5or' and t hot N,ther Uades, in the 7-,76.11 inn of tneir 10)17 and U-.at 010; nor lxadro, and shall make. 0- pay :or , all necessary reparo to restore damage to lire- 1:,v. 70.0 1.0..1' no coot 1, the liwtifir 9. EElean. cum Esulpnnrnt and Wlnng- 1'r:ni3e il „n; -c ,;Cndu,o and wire tie..r. ai.ated with the me• non tam equipment hst all in •i +-nrl.lr..e w I the - eg.,lrcmenar, of the slot :t ricai work. PraNe c.onpleta cnrtr,ls shop u+eln,+ pa_4a ^r fn- review: 10 Prm.te fFnul as -bn't elra.vings en.a i11,-t1•r:an.a in.,n.:01R. 11. pale -Org Bu•anre a!: ol- outlet s 4:..; in r . l 7, of that sho.m on the,l-0 /1ngp h1lance,,te be )0"01ned Fra torn, 12. This •0. a 24 'n.:u -hday '/:toy /were -r:,. aI 1101 f::r0 ; rrguming con Gnuols operation at a i-on'i ant terlrr- at1re uet.roint, fen 1 NRF 1412 4 1 101/17.111 /07711 :01-c !,02 7,111: and optimum start Controls art 007 re ,i.i' e0/. Product s 1. Use all ,1771,0 necessary to prate;. n+ 1:rr.0 /1. more, during ano :ftrr 1, 5ta1 ntlon 000/ 10 protect Via Instated WO, Of 07hrr 701)7: In t■n event of damage, nlm:U.ately make all repairs and 07piacer77rtt5 100e^sar4 t0 153 app'••naI o' toe Owner and at no .'.dditional cost to the Owner 2 Water Piping: Typo "L" capper with iroce71 o- forged capper fittings. lead ftoe cioider. 3. CAW P!pm f: F.II OVA' piping to be no- Ilub •:opt iron alth 011ndard fit-1,147 0- copper. 4. Sheet Meta!: All a „gTADlry to be ante-, metal and comply ma SMA.CNF. Ductwork Standards. - 3'5.1 5. Duct Insulation: See insolaU(m tet o tur thcLnes Do not inrsula:e ductwork in data ,;enter. 6. Water Plpe Inulat ion' See in.:laUOn 1077 for thictneos. Fibergiara •routaUon with flame• rttdr,lant. l -aft raper v.tpc- truer Prl+vide Prc'airncatcd 1ne.rrlat Insulating Fitting Cover,. 7. H /'2IC Equipment: Furnish and ir,'a' Hi.'•• as •know, .r 1.^, achedules located nn the plans. Execution 1. Prior 70 any work or fabrication, 1arefu1:4 In: pest the existing eondn.an, and verify that all such colk+itene are compatible 10 t'.7 p,.n_ whore :hie, installation may Commence provde shop drawings of all ducto.Ort and 'voc rguipmont for engl.urring rev.rw. 2 Plumhing-watorpidnrg: a. Mato all pinta in capper tuts YT-n !.a., fr_tr noLrer aprl.e0 in strict actordarce with the manufacturer re.dornnriendati,nri b. Make a1 tape pcnetrat +ono :.n door., finis": ,1 71 rnnf water and a •t.iarlt. Provide piping auppnrtn a5 re.nju:red by .•0.ie 'n,.151. rte' UP::. 3 50041, Metal. Construe icr and 11 71 )l'0700 of 11 1001.04 shall comply with all SMACIJA. Standards ;3" 5. 4'.;. 4 Ali d :stir•/ shall have 511 tran'oornc o:, t5 and on:au :d•ral learns seam, scaled. All ductwork shall be psalm it nccordnnce wt.n '_•wr.1a•d ite-T S. Rcecrn d•mvngo nba I be /ept rr Ri'.E an:t ;:pool ea )a F: Provide measurement to all underground and ,onoosled work. 6 Ail re:evant.,rtuirrment 5 ('011.01,0149.. 0, the 2006 Washington Slate Elegy Code incl. ,. .g, but not Lm ited a. provision of •&urn drawings & manual:3 baton, rig, testa .7 &7011111i0010111114 shalt ne 'ulh: •slier'/ 0r..h. %. Provide con-plet0 'actor] a:v1r:up 1 0.101:6101 -to of !IVAC 0,. m ne0t. FILE C PY End of MCLltaneal SFecificdtions. Permit No.. M10- OR ( Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt ni approved Field Copy and conditions is acknowledged. By Date: Zo(O City Of Tukwila Met NA -A•• LEGEND 0 NEXIMMI 5D 1111=1! DUCT - FIRST NUMBER 19 SIDE SHOWN SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN DI 0T UP PE TURN DUCT DOWN 501. ARE ELBOW 5O11ARE ELBOW TURNING VANES EL BOW EGU.'JD ELBOW TURNING VANES F'OLND 10 1ECT:NGULAR 1 P.ANS-1110N LARGE TO SMALL TRANSITION i:IPECTION OF FLOW INCLINED DROP IN DIRECTIC N CF •.IB FLOW ItJ1:..INED RISE W DIRECTION 77 AIR FLOW F 7 0/ ...RAE DAMPER WE DAMPER �r,t.tOf,E D /JAPER ''IP.Ei9MO:E DAMPER •Aar0E1ZE7 DAMPER :,G;E15 DOOR. r, ilea; CF12 THROAT SIZE CHILLED WATER SUPPLY CHILLED WATER RETURN CONDENSER WATER RETURN GOLD WATER PIPING HOT WATER PIPING SANITARY SEWERS VENT LINES DIFJ5_ R 1,11E SEE SCHEDULE SGl'rti`iA1E PERMIT REQUIRED FOR: ❑ Mechanical tectrical erAtumbing @Mas Piping City cifit, "fa ;CHOW BUILDING DIVISION Q{- OR lr 1L5OW UP SUPPLY OUTLET CEILING DIFFUSER ARROWS INDICATE iriRir:J DIRECTIONS 0 THERMOSTAT ABBREVIATIONS (X) NUMBER IN PARENTHESIS INDICATES QIJANIIT! DRAWING INDEX M -I = LEGEND AND SPECIFICATIONS M -2 = MECHANICAL. FLOOR & SECTION = DIAGRAMS AND SECTIONS. 1.2.4 = SCHEDULES REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 8 2010 City of Tukwila BUILDING DIVISION C-4- oe C- 4++ OR 1- -0o- -- ELBOW DOWN TEE iEE UP TEE OA.%7 'LOW DIRECTION PIPE F'ITCH UP CR DOWN. GATE VALVE. ....ECr VALE. ALL VALVE 2 -WA1 VALVE. 2-WAY AUTOMATIC CONTROL VALVE UNI0i1 17.'l STRAINER. PRWSLRE GAGE Wi SHUT -OFF vALYE THERMGM -TER. -0- METE` ". CITY OFEAUKVNLP` JUN 21 2010 PERMIT CENTER MOOV 2 Lu 1- cn ,>- V / Vo 2 0) 22 J_ CL W 1- z tW 1- V Q 1- o J 1 m U Z J Q re Y P- O z; N N HUNT ENG. JOB I. HUNT 11 DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS. A 6/712010 FOR CONSTRUCTION • • • A • SHEET CONTENTS. MECHANICAL LEGEND AND SPECIFICATIONS SHEET NUMBER: M -1 1 OF 4 C 70101 410,1 e. 601, 10101051.1 1000121 .1. i FAN WALL POP (FOR CRAG B1, '2) V50 - PROVIDE UNISTRUT STAND AND MOUNT FLUSH WI FAN. STACK 1 SWITCHES AS REQUIRED. (2) M E `- MOUNT NO DEVICES TO THIS WALL w-�J -vim FUTURE ORAL #4 •JrN rF.Y URE 1 TERMINATE. IN JANITOR C_OSET. "'1 SEE PIPING DIACiWAIv' FOR r -- --• -. -.- - -__.,' --...-- -,d % ADDITIONAL CJFOR.MATION. ,-., r ■ > RF -1 & 2 5 r± VET:41E5 �1f-- 1 1_ _ T -f. II I I �1 i 1 I 1 T _I TFUTUREi -- - I -114" CONDENSATE 1?OAIN SEE FAN WALL CONTROLS FOR PRESSURE SEN5OF: PETALS. r � L_ _J 1- 1 I_ _I 1_ _I RI ri r r ri 1- FUI UFE LCILIVEP I r:1 r.1 CJ FU" UPE CRAC i I i - -Y I 4.100 1 1'.'1 4`'1.12 L I A' 1-t 450-2,4 1 -/ 1. E' C :. ! •;." +- ROLLER - P` F 'If F /)R;',1PT W/ TOP ,V11; F•C'"T0M P'P, 1Ei 39.24 1- — I 1 L J C;17.L, FUTJPE) SEE PIPING DIAGRAM F) i :.DDII IONAL DETAILS OF N.P.A'. A'.D :'LMr -EC' CONDENSATE DR% IN J / MECHANICAL PLAN SC A_E: V4 " =' .. 0 I 2 4 SCALE 1/ 4"-1.-0" PIPE r 1"F'` ?.I' 511:E ET LULT J1 01 F+. 11 : I II • Lr�, 1 F •RF) RC'LLFI T F1 FI' 1F TT L) 1(.1.'ULL ER ONLY -� 'f'. 7:: /- E %. -•, 110-1- F2AN1•F. ) .'`•,or' 1.3'noOYE^oE:. (FUTUREI 1''l. £I.vt, ;I'T ter. >��•2BEf.MW, FL T_I ET.1- .,1'L'1:''E d:; SPUCT'URA_ 1. 1 Fly t -� FE. SI PPOF I SEE 51E L1C1•JQA.. F: �::F'':_= '1 rFT 3.- .. 'F)I1 .0 I /170'.1 �:.ENUM .vJ..cc•-, �1, 11/ 13" -5 -112" 11' 0' ANGLE SUPPORT DRAGE BAR JOIST (W) F :1S'1NG CEILING & TILE T,, HE REMOVED 9' O' 17 4 71_� LOLI EE. Wr 1.1; 14L COVET 011 -`-" -71 EL FT.C;E ':' UVE 3 PUO115 TO /17/2 . TIFF. E. PPgr T, -EE 5' TUCTL1CAL F / -P. LET-.1LS 1 00117E 2,::)111. I lam- -: 1':t1UPE DF'1PF J FJi,J' ; cri,C x2 :FJrJI•'_) Cr- IM' :217. LCHU.'.F.L-'::H..1- 3,1111., AND RFTL'1. 7 / S;T SI'WF(OWN 1_1-1 ->':' M)J'4 '1'41S r', =1•.: BDD - RUST IN 006 F -._EX CONNECTION 6" P:.1 3TEEL GEM'S 3 CHW'R 60x24 HEADER I BEAM U5E SACK OF HEADER FOR PLENUM SIDE RFTUPN PLENUM WIDTH OF CRAG UNIT �� :1504 OR DUCT DETECTORS. CONNECT FOR UNIT SHUT 0- JN (BY OTHERS) CRAC x \1' TFTUPN PLENUM DIVIDER i 2; 012. TIGHT LIGHTS 7a PIL 01 LIGHTED SWEICH 06 EXTERIOR 01 F" E141 M (BY E.C.) ' .1NTT-CIL DAMPER PPE F:l. TER ,/)3,' ACCESS PANEL FIE PL ?a E (F1.) WINDUN W/ O'A'FEJDAMPERJ FIL1 EK E•EMBLY SCE DETAIL® IAL VIPER. CUSTOM FIL1E1 '71.1.•'1 4" DEEP L'SR FILTER. 1 NI RL SUFr RTS V F1- E.-it '111 27[17p3?, '.: TC I' L- 06 l CA-•,AC ASSEMBLY SECTION ) 1.2 ':01l1R-)L C -'.MP1T', L 03''.EP BLANK F ; ?U REDUCE C;; NTF'C'L Ph,MPER SIZE TO ACCOMMODATE ,,C? IATUE P E R EQUIRED r B \WALL LOUVER /SCALE NONE BOL_•FC i'i`MOOR HAS'. -Or,' FL 11: RE) B At' 117 AE . i. •OL _ ,=L:IUPE) r `EIJCE RY GT'EFF 1 � - DOWN IC FIR:;( FLOOE. ,,FUTURE) H1LLFT ?.'•1L 4.. CIA.. TED PIPING :51 FLOOR DEL LI, C'A T? ,;ENTER ON OUTDOOR. DRIVE •,� P.r-'11-/.c , TO FAR 1,4C-, GARAGE, "LT E.NCE RU St 17111' ;C' T1riL /- E COI111.;O'. 1..)/1APFR -, n,C ;i)Mt'01'41 E C'1.15GAK1 .1401 2 PEFP201 FILTER. PLEATED — tr. 1 KJ :1 UP: *.L ST, -.NP FOR CE AC JNIT I;IIE 1 .16 _3'; 5D ('-\\WALL LOUVER C �E.,CiLE NONE CITY ECE'i CITY Of TU JUN 21 2010 PERM-CENTER, LA J1U1:E CHI1LER FUTURE CHILLER r F JTURE CHILLER REV1 WE FOR ,/ CODE COMPLIANCE APP IWED -JUL-0-8-2010 L L J City of Tukwila BUILDING DIVISIfN Engineering Services Inc • Yva Read ME eac.mr 15 56 55110 • 206110.11917 ... >m. 00,100, 201 . E0,014121,00 SERAC£5 • ryFicAl. EF W/20 ,../A SHEET METAL 1 • ()FAN WALL ELEVATION FAN T11% 1.1. 2.0 t 74. NMI 1 FRAmEr 114 ' '51'-'E71.1" • "! ,i,m•:,.•„M.L' • .1 1-1F-1 •C,N r Ti'. TR, :. 1, . FLO' ri ': II .. -WV .',.:E,.... — . .1 ‘...., .".....„:„........„,,,,,-- — J.' / 1..------.- I- eLm.1E -.., ------------ w --------- LEGEND 1. .51-RAI14ER/SLOW R'.C.WN VALVE 2. ENE ANSI...11 3 '311' NI C.: RON PC.RT ,..qATURE ACCESS POET - - E. 1' R.-.IN PL JO --------------- m CONSTRUCTION NOTES l> PROVIDE CHEO VALVE, ISOLATION VALVE, W/ LOCK SHIELD & HOSE THREAD END WITH CAP FOR GL (COL FILL STATION f>. AIR SEPAR ATOR AND AUTO AIR VENT. LOCATE AS NEAR TO CHILLER AS Po.asieLE. MOUNT SECURELY TO PAD WI GALVANIZED SUPPORT. NON POTABLE WATER — LOCATE Fs/ JANITOR RC .-.0.K111131E t'LRLI'110 OWNER. ' 1-1 /4" PUMPED CONDENSATE AV-1 A5-I — WORF IN THIS AREA PART OF / 1'3(1 AGED L:HILLER 5Y5TEM 2 \— 3/4" 1/2" DPI,IN TO ffAC OF MOP 511R F :LEF 1,1■N V A L,75 = • COsiNE,:. TIONS F E EDUCING/FRI. VAL', E TO:T. AND VENT ET1 F.; ;AC -E TANK F EFL ....C.: (E.; W11. r -■CMIr AD_ JE. E DJ1.51.° 5t E rfq,EL 1-13, P.M,IF AC' U.AT.),3 F .TA, r.3-• FAN WALL SECTION E 1/2" , 1 ----REVIEWED FOR CODE COMPLIANCE r 0/30 - APPROVED JUL 08 2010 1/330 WII1 Tu HAVE 1,33 TOE) 3-WA t' FEI 3' LL ED rEc. FOP 1 11-011E FUTURE CHILLER PIPING DIAGRAM SCALE': M 11-7. POWER 1,1.1K !NO 2 DSC 5W 2/10101/3 CONNECTIONS 13`r E.0 NE/3 N.-AT :1, 1 :11 ,:-M.EF; , TORY ONTROL 5FSTFM H FTC1C E..- 'SOW ' ET. ONTROL S'53214 FOR HF 011/3-1' :11A ..1 Fr' ' 531 TEM • 1.3E 1. F'R 1 PRE:17 NTOF: HAL_ v, • ,E.HINC•Ti. 1: 51.47E CE "T. OF E .1 r, F'11;`.1:' Z.' LI 5' 5,:1-IEL. _1 LE -1-0 STEE._ 47. E C,.. • 132 PRESE L FE SENS. DT "I.:, 3.3/3 C.ONTPOI F0N3 COA,!Pliit F.00M rOSITIv'E TO SC !LPN.; 'TC.FFIDOR M /34/3 -1 PC4111.:E • EC City of Tukwila BUILDING DIVISION ,:,"■;17-F .01/01.1/3 --0 OPEN /3/3/3' F 01 1 11 111711 C•FF CF.AC A IF Ec....;.•1,:!:.!!zEr: rs LOCI ED OVERSIZE SUF'POPT mOL. 3,31310 --FRING CPEN POWER. SE MOTORIZE, DAMPER_ FAN WALL CONTROL DIAGRAM SCALE. N.1.5. crtSgemtit JUN 2 1 2010 PERMIT CENTER 1 Engineering Services Inc MO la ft.1 ...bp Is WA IWO Runic 2Cd.t2.6917 20180.69{8 E w 1- (1) co 0, < > as ( ,- 270, ci ce w z § 11.1 0 I° < ci C) > 1 co z 0 < < ;.1 Ce k" P- 0 E, pii HUNT ENG. J08 #: HUNT # DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS: ,L 6/T/2010 FOR CONSTRUCTION ,L SHEET CONTENTS: MECHANICAL DIAGRAMS AND SECTIONS SHEET NUMBER: M -3 3 OF 4 203 by H., DHOINEEYNC 3.ERYCES 1 CRAC SCHEDULE MARK MANUFACTURER / MODEL COOLING CAPACITY • FAN DATA CONNECTION SIZES ELECTRICAL DATA HP PHYSICAL DATA NOTES NOMINAL TONS TOTAL (MBH) SENSIBL E (MBH) GPM PRESS. DROP (R. 820) CFM HP E.S.P. (In.) CHILLED WATER (in. 0 D. Cu) CONDENSATE (5. FPT) HUMIDIFIER (In. O.O. Cu) VOLTS/PHASE FLA MCA MCA LENGTH (in.) WIDTH (In.) HEIGHT (In.) WEIGHT (Ibs.) CRAC4 14E0E111 10.1114- 2- 5 -5.5 -3 45 541 412 110 4 7 21.001) 20 175 2 3/5 '-1/4 114 480139 77 1 971 111' 127 34 76 2100 SEE NOTES 3EI.ER.AL .10155 503 PH) W/ CUSTOM FILTER RE[LIRN SEE `AC ASSFId2LV 5251105" MODULATION ./:45115 ECONOML2E5 OPERATION LIFDERT RAM CONTROLLER. CHECK VALVE 40 1 NIGH CUM 557 041055 CRIE.:K vA L,E; ' 00011'43 NOTES C°When,' t512.5 DU. 60, W13. UNIT DISCCNNECTS KIT- CONDENSATE PUMPS 01144 2050 MOUNTED RE /URN INTERLOCM. 3 CONTROLS FOR 100% PEHE.11. 11545850' 'UM D;FIER. PUMP (REPLACE FACTORY DRIP PAN FOR ENTIRE MT. 1' LIP SNMP ERROR REPORTING 1 PROIVE :' P1011VE 3 040510E ..PRO, !PE E[EC1T1C CON' IFNSKIE 1 PRC71n['E .5 PROVIDE CHILLED SCHEDULE DELETED EXHAUST FAN SCHEDULE MARK MODEL !DESCRIPTION CFM 56 )/n.) RPM BHP HP MBA VOLTS PHASE WT (1b.) NOTES .r. 55'E'.HE'.f .56E - 31»0 -100 /542 Vr ,Ll. 17511 DRAT E7- 4,1/5" 4,1/5" E., •I _ 2„.c,, ,.. .,, !00 E^ ago 3 :h. 4J N TE '. L GP'E'.HEI 517E -:I. -5 -102 r50F...K ,U. 5E.' -1 DRP.'E F.. -a.UST 5,••4 3,.0•.0 _... 4._ _ '00 E 460 3 450 NJTE'1 N01E5 .J1 FO4'r 5 L '7.0.N1 ,5a. I Lb 5F ,f'O R.. -F J ":'0 Mil" (:A:'4 D FOR' 0114EE" I'501105 P.,^. !01-3::011,041 51',5 1 -100 51'4 at '2_000 ; E'A OPFPAT' S 0' 152403. 502- 24'Z15 PRE2,0U5 9_5CJ LFM :2140 1.105 45 45A. 1 KP ?L-. MO 0444 iDE ....5E •34 4 REVIEWED FOR CODE COMPLIANCE ,APPROVED JUL 0 8 2010 City of Tukwila BUILDING DIVISIf1N RE FENgt art o ,JUN t. I .010 PERMIT CENSIk DAMPER SCHEDULE MARK MANUFACTURER / MODEL / LOCATION S. P. (In.) FREE AREA (sq. R,) SIZE mm s (5M" ■ h ") NOTES 12.4 RUSKIN / L5750! OSA .08 12.71 60x60 NOTE I 12 -2 BUSKIN 1 13/52 t 05A 08 177/ 60,60 NOTE 1 113 C- REENHECK /EAH590 /OSA 04 24 30460 NOTE2 GP -1 R•JSrIN!CD4OT! +1N,INE! 051 05 .- 64060 NOTE 4.5 CL' 2 R)54 IN I CD 4014011 ,INE J 05 -- 60/60 NOTE 4. 6 ;�, -3 R'J5f IN! CD 40 THIN JNE! RETURN .11' SHEET NUMBER: M-4 :2024 NCTF M '4FJ!')A' OALANCE. 7 AMPER RUSE IN'CP4 05 5120 Pr 1' LOCA,TCV4 CN P''. AN NOTE 5 P D.0 415504.1 D06 05 SIZE FE 4' LOCATION CN P'AN :O1 r'.i I'2'.100 11 3 1/4' 51(1141 :KEEN :' M': 105L'E[' LOUVER SEAL 131.1555 51,E C C "(4 D1NA'E EXACT SIZE yr'TH M51.110`.15 ON E05114G'MNIICWS IN ,REM. OE II:E 54.LLJ 0J44 -n, 10 MEET WSE': 'r ['E CRAM. ARM AND ' -AN0 12 '171.ZAN' . 7271 _ E SIZE 11 REQJIRE O 405.. M0,01:IZE; ACTU51OR 1N5T/1_A *ION 11.11E MULTIPLE U'.115 35 RE;'J:"EO. MISCELLANEOUS EQUIPMENT SCHEDULE MARK DESCRIPTION MANUFACTURER I MODEL WT 11b9.) NOTES 75.1 r. ..'EF °5'.1'5 , \RMSTR0N21145 ' I- 0 3E.EG'. NOTES F.J135 /'I'EN1 ARMS- IRONG/ AL IL) .•it;. :11 e:'1 I in OP a:11 SETTEE. EEL ANCE l'A1 YE A5MSTRj3r:; 05" Y ';04[_ O F, N N DIFFUSER & GRILLE SCHEDULE * PLAN CALLOUT DESCRIPTION MANU- FACTURER MODEL NOTES -. CRJM 544151711 SPILL5 TI11J5 I- 0 3E.EG'. NOTES Q 1- ' 515 'CANS 5Ofl. 1EC7, S' e MOTORS Minimum Nominal Full -Load Efficiency Op, x411,6 Closed Mb1ms S7na"'m6s Speed.12MI 3.90 Hn '5 /0 825 84.0 840 955 900 1200 E6,96ncy 025 300 910 840 840 855 88.5 865 875 875 3600 190 1.200 E7565,,y P 1 755 825 600 825 840 055 840 640 655 .15 675 975 575 675 3/5 I) 5 .ro 24. 40 50 60 75 100 `25 200 875 915 695 902 91.0 91.0 917 934 930 630 930 936 936 94.5 685 69.5 910 910 91 7 924 910 030 016 941 94.5 945 93 980 0 885 992 90 2 910 917 92 4 930 930 936 935 911 94, 945 915 185 600 902 .2 210 910 91.7 92x.4 $0 310 916 945 045 950 895 89 5 910 910 924 924 930 930 938 911 945 945 959 950 89 5 89 5 90.2 .2 91 7 917 930 930 936 938 94 941 900 959 Excep'.nns. 40.ars 4' s.413'18 desgred 6, use nore than em spec, of a minbspeed TOM, x !Cars aedady nclude4 n 4/, affcercy /enu rerenl5 r9, H: A3 aeon/rent ! ra05s 14.1 o4 -21. • 1.4e14s 8Matare an nteyral partr'.e nit as45 n 5-X44 and rep'aced of speceaed 09cess equpdonli'a em4244n3wncn /enures a specialrrotor 9,.ch as an ex/lemon- prop' 'rswrl. a Mow?, nte9ra11a a as red pets of e1.Fmen: for 4/ Nch 'w pue45yel9 motor nue teen s /pr004d 0 0 4Ire only 'UL 'x154 for a'e e,uprent 8 , 41 a 894- 816900t rote r and there i5 m 85734 81 tent 10tor ootc91 For rotors daring an exteplon, 45' row/ end rote •'uct ex /e5en 260308. 11-9LJINT (Engineering Services Inc.! 1** ME '_!464 Ic w M10 Awns 3068{2.691) roc 106.!{269111 w 1- ) co O°0 r 2 J N _ W 1- z w I- 0 Q 1- I in Q J Ce Y P- O F, N N HUNT ENG. JOB 4: HUNT 8 DATE ISSUED: 2/19/2010 FOR CONSTRUCTION REVISIONS: ,L 12/2910 - FUTURE WILT map E7R910 . FOR CdglR ICI1ON SHEET CONTENTS MECHANICAL SCHEDULES SHEET NUMBER: M-4 4 Or 4 <:F•Maw• 20' a .64 rncwc"n9 65,•44x1 � PERMIT MORD COPYM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -081 DATE: 06/21/10 PROJECT NAME: WOWRACK TECHNOLOGIES SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL, STE 110 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued EPARTMENTS: -7_1_10 uilding Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 06/22/10 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07/20/10 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name VITAL MECHANICAL SERVICE, INC. UBI No. 602410867 Phone 2536306933 Status Active Address 13106 Se 240Th St Ste 101 License No. VITALMS964MM Suite /Apt. License Type Construction Contractor City Kent Effective Date 7/21/2004 State WA Expiration Date 8/8/2012 Zip 98031 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date ALMON, KEVIN LEWIS President 07/14/2004 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC SG8008 05/28/2010 Until Cancelled $12,000.0005/28 /2010 2 CBIC SG8008 07/20/2006 05/28/2010 $6,000.0007/11/2006 06/01/2007 1 DEVELOPERS SURETY & INDEM CO 543265C 07/20/2004 Until Cancelled 08/10/2006 $6,000.0007/21/2004 /29/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 WEST AMERICAN INS CO BKW53465203 06/06/2008 06/06/2011 $1,000,000.0005 /21/2010 3 0010 CABINS BKW53465203 06/06/2006 06/06/2008 51,000,000.00 06/01/2007 2 LANDMARK AMERICAN INS CO LHA128236 06/06/2005 06/06/2006 $1,000,000.0006 /29/2005 1 AMERICAN STATES INS CO 01CG607629 07/16/2004 07/16/2005 $1,000,000.0007 /21/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/09/2010