HomeMy WebLinkAboutPermit M10-085 - DOUBLE TREE HOTELDOUBLE TREE HOTEL 16500 SOUTHCENTER PY M10 -085 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 2623049127 Address: 16500 SOUTHCENTER PY TUKW Project Name: DOUBLE TREE HOTEL Permit Number: M10 -085 Issue Date: 07/13/2010 Permit Expires On: 01/09/2011 Owner: Name: SOUTHCENTER MOTEL HOTEL LTD Address: C/O POER MARVIN F & COMPANY , 500 108TH AVE NE #780 Contact Person: Name: CHRIS LEE Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Email: CHRIS.LEE @MACMILLER.COM Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206 768 -4266 Phone: 206 - 768 -4180 Expiration Date: 12/31/2010 DESCRIPTION OF WORK: REPLACE (2) PACKAGES GAS HEAT ROOFTOP UNITS WITH LIKE- FOR -LIKE TONNAGE REPLACEMENTS. INSTALL (2) CURB ADAPTERS. DISCONNECT AND RECONNECT POWER WIRING AND GAS SERVICE. PROVIDE (1) RETURN AIR SMOKE DETECTOR. Value of Mechanical: $18,500.00 Type of Fire Protection: Permit Center Authorized Signature: Fees Collected: $374.31 International Mechanical Code Edition: 2009 Lk) Date: 7— ( 3` 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: nei /49-64 e-- Date: 7413 ho This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10-085 Printed: 07 -13 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049127 Address: 16500 SOUTHCENTER PY TUKW Suite No: Tenant: DOUBLE TREE HOTEL PERMIT CONDITIONS Permit Number: M10 -085 Status: ISSUED Applied Date: 06/25/2010 Issue Date: 07/13/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M10 -085 Printed: 07 -13 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa. us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -085 Printed: 07 -13 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: ordinances governing or local laws regulating doc: Cond -10/06 M10 -085 Printed: 07 -13 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Permit No.,� Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 2.6117014 - g(7-1 King Co Assessor's Tax No.: 6437300020 Site Address: 16500 SOUTHCENTER PARKWAY TUKWILA, WA Suite Number: Floor: co`D Tenant Name: DOUBLE TREE HOTEL New Tenant: ❑ Yes O.. No Property Owners Name: DOUBLE TREE HOTEL Mailing Address: 16500 SOUTHCENTER PARKWAY TUKWILA WA 98188 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: CHRIS LEE Day Telephone: (206) 768 -4266 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 Zip City State E -Mail Address: CHRIS.LEE @MACMILLER.COM Fax Number: (206) 768 -4267 MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip Contact Person: CHRIS LEE Day Telephone: (206) 768 -4266 E -Mail Address: CHRIS.LEE @MACMILLER.COM Fax Number: Expiration Date: 12/31/2010 Contractor Registration Number: MACDOFS980RU ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: N/A Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: State ENGINEER OF RECORD -All plans must be wet stamped by Engineer of Record Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip Contact Person: CHRIS LEE Day Telephone: (206) 768 -4266 E -Mail Address: Fax Number: H:\Applications \Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 1 of 2 • 1 Valuation of Project (contractor's bid price): $ 18,500 Scope of Work (please provide detailed information): REPLACE (2) PACKAGED GAS HEAT ROOFTOP UNITS WITH LIKE - FOR -LIKE TONNAGE REPLACEMENTS. INSTALL (2) CURB ADAPTERS. DISCONNECT & RECONNECT POWER WIRING AND GAS SERVICE. PROVIDE (1) RETURN AIR SMOKE DETECTOR. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas Other: BOTH - SEE SCOPE OF WORK Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 2 Incinerator — Comm/Ind PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING " ` o • : UTHORIZED AG Signature: Date: 06/25/2010 Print Name: DARLA DOLL Day Telephone: (206) 768 4278 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 Date Application Accepted: City State Zip Date Application Expires: J z-/ (o Staff Initials: H:\Applications \Forms - Applications On Line \2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 hh age 2 of 2 w A City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049127 Permit Number: M10 -085 Address: 16500 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 06/25/2010 Applicant: DOUBLE TREE HOTEL Issue Date: Receipt No.: R10 -01163 Initials: User ID: Payee: JEM 1165 Payment Amount: $374.31 Payment Date: 06/25/2010 12:00 PM Balance: $0.00 MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2550 374.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 299.45 000.345.830 74.86 Total: $374.31 PAYMENT RFCFIVED doc: Receipt -06 Printed: 06 -25 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 \W___PERMIT NO. P ject: /)o �� e �r� '+0T) Type of nspecti n: III , n Nci t" —"; NJ - A4Q/Ai�cJ Address: /(45o�� snip t� Srvt o ►Cry � lMi .ri ki. Date Called: 1- P�.r4 (1.o - - 4 ,� A) — N 1 Y Special Instructions: �% v 4 2 i Z !' `7 e d" e s N��- e s ,e, A /,M `d Date Wanted c —! .243 10 ,x1.01. p.m. Requester: 1 Phone No: Q I Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 e�1�1 n Nci t" —"; NJ - A4Q/Ai�cJ Q. t� Srvt o ►Cry � lMi .ri ki. p r °J 1- P�.r4 (1.o - - 4 ,� A) — N 1 Y 1 Date: A, -2 0 EINSPECTION FE� REQUIRED. 1Prior to inspection, fee must be 6300 Southcenter Bl d., Suite 100. Call to schedule reinspection. Date: 1- EXPIRES JJ—Z%ZeV) 1 K I A C O 1802 W Lake Sammamish PKWY SE Bellevue, WA 98008 Phone: 425 - 644 -6400 Cell: 425 - 351 -5999 PP DOUBLE TREE HOTEL MECHANICAL UNIT SUPPORT 16500 SOUTHCENTER PKWY TUKWILA, WASHINGTON 98188 FOR MacDonald - Miller Facilities Solutions STRUCTURAL CALCULATIONS JUNE 18, 2010 JOB NO: 156 -1007 C REVIEWED FpR ODE COMPLIANCE A man1/E® JUL 12 2010 City of Tukwila BUILDING OIlminA aTVOnnu► JUN 2 2010 PERMRCFIdIER Mao o�ds ■ v.') zx, g-�� gGJ4' 6P8 # PARTIAL ROOF FRAMING PLAN < /t1 Z NOTES: 1) CONTRACTOR TO VERIFY ALL SIZES, DIMENSIONS, AND LOCATIONS AT FIELD. 2) CONTRACTOR TO VERIFY ALL EXISTING ROOF FRAMING MEMBER SIZES. 3) CONTRACTOR TO VERIFY MECHANICAL UNIT SIZE, WEIGHT AND LOCATIONS. O o a Pro occ5ubiea �o r/l�GE '2 ,yo�EG rl/� +"1L65 \";•' BY Date G _ A® Sheet No ) 3 Jab No J L L 1 Est�sr: ,S °J,� L.' J Roiecusuoiea 7 /X ► -�)LA� �� $h6ei No 6 _Jc Z )3 .lob !b /32 —J dO7 ROOF LOADS: DEAD LOAD: ROOFING 2 PSF METAL DECK 2 TRUSS JOISTS 2 SPRINKLER 1.5 INSULATION 2 PURLIN 0 CEILING 2 MISC. / MECH. 3.5 SUB -TOTAL 15 PSF LIVE LOAD: SNOW 25 PSF TOTAL LOAD: 40 PSF MECHANICAL UNIT DATA: AC -I4 = 688 Ibs + 119 Ibs (adopt. curb) + 56 Ibs (exist. curb) 0 v Q ProleaSttbgtct By Sneer. No. �3 Date Job No ls�J°p7' 4'F '�l/.J1; 05 0.11: 7idsl 31 1 Jc G > �✓„ : 4-) ; L✓L 736 2'2J .)7A.✓ s Go lit -/a 'J 41 1,04 -> . GS° Jb s 1g�� `� I ' �,q )& = �O ■- J) y ZO Zo fr /'� r').»,74./, : eyI 3 Sc 6./g = ),_.350 >42/)k:) Ati )Bp/, 4-) 3 x 6 ,o/ ) Z, 3�� > 4,1 Zg7____„, . f.,, 0 Q ,Y BY f'6r: Date Sheet No. 4'7 3 i�G -1�p7 LATERAL DESIGN:(IBC 2006, ASCE 7 -05) (A) WIND - BASIC WIND SPEEE 85 MPH (FIG. 6-1, ASCE 7-05) EXP. "B" Iw = 1.0 Kd = 0.9 (TABLE 8-4, ASCE 7 -05) Kz= 0.7 UPTO30' Kzt= 1.0 (FIGURE 6-4, ASCE 7 -05) Gf = 0.85 (GUST FACTOR) qz= 0.00256xKzxKztxKdxV"2XI (EQ.6 -15) qz = 11.7 PSF Cf =1.3 (FIG. 6 -21, ASCE 7 -05, H/D < 1.0, FOR MECHANICAL UNIT) F=qzxGfxCfxAf (EQ.6 -28) F= 12.88 Af UNIT LENGTH (L) = 5.8 FT UNIT WIDTH (W) : 3.7 FT UNIT HIGHT (H) : 3.00 FT SHORT DIRECTION F wind = 291 Ibs LONG DIRECTION: F wind = 186 Ibs 0 4 FtcheaSulmcl .L7 or/,rGE���E �6 G v✓/G� / w� By Date I' �� Sheet NO. Double Tree Hotel MCE Ground Motion - Conterminous 48 States Zip Code - 98188 Central Latitude = 47.447736 Central Longitude = - 122.273462 Period MCE Sa (sec) ( %g) 0.2 133.7 MCE Value of Ss, Site Class B 1.0 046.0 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 133.7 Sa = FaSs, Fa = 1.00 1.0 070.8 Sa = FvS1, Fv = 1.54 «3 SEISMIC (2006 IBC) ZIP CODE 98188 LATITUDE 47.4477 LONGITUDE - 122.274 Ss = 1.337 g S1= 0.46g SITE CLASS "C" SDC = D Fa = 1 Fv = 1.54 Sms = Fa x Ss = 1.337 g Sm1 = Fv x S1 = 0.71 g Sds = 2/3 Sms = 0.89 g Sd1= 2/3Sm1= 0.47g Fp = (0.4 Ap.Sds.Wp /(Rp/Ip)) / (1 + 2 Z/H) (EQ. 13.3 -1) Ap = 2.5 Ip = 1 Rp = 8 Sds = 0.89 0 4 Ptolom r�o�/J? THEE �i�>EG >�/,� wrG.9� �✓� By ,9.6, Date Slieei N� 13 Job NO fcA.100, Z/H = 1 Wp = 688 Ibs Fp = 307 Ibs Fp(MAX)= 1.6 Sds.Ip.Wp = 981 Ibs > Fp O.K. Fp(MIN) = 0.3 Sds.Ip.Wp = 184 Ibs < Fp O.K. Fp(ASD)= Fp/1.4= 219 Ibs (WIND GOVERNS IN SHORT DIRECTION) CHECK UNIT STABILITY: SHORT DIRECTION: F(WIND)= 291 Ibs M (O.T.)= 437 Ibs-ft M (R) = 1273 Ibs-ft 0.7M (R)= 891 Ibs-ft > M (O.T.) NO UPLIFT USING: MINIMUM (4) -#10 SCREWS EACH SIDE OF THE UNIT / CURB F(wind)/#10 SCREW 36 Ibs - O.K. O v 4 Project- Sub;en TV/ev✓j G #i v✓� BY Date G -Jo Sheet No. �3 Job No APPENDIX I)3 TRANS. Dimensional Data Figure 3. Cooling and gas /electric - 3 -5 tons standard efficiency, 3 tons high efficiency Notes: 1. All dimensions are in inches/millimeter*. 2. Va NPT Gas Connection - (Y_C Models only); 2' Electrical Connection: Single Point Power When Heat Installed (T_C Models only.) ALTERNATE 4.44NI CIA HOLE �. TOP PANEL O1310EPt88h PAN -I • °MOONIER 000. • tie correct WM 7/f COM 01AI$ 7 .E Wy I?ig. 1117W ut 'on 61600NiinUN —/ L M scone PAN. EEFMCr CAME PORT' MrFBB 1 W & 8 01.A HOLE LOU POLPERMiE 1 /rpsW1 MA MOLE Figure 4. Cooling and gas /electric - 3-5 tons standard efficiency, 3 tons high efficiency downflow airflow supply /retum - through the base utilities Note: M dimensions are in inches /millimeters. MH 356 MM M 235 MM 102 2 810 r RETURN MM 15 1!1 "—.. 394 MM SUPPLY 16- 406 MM TBU CONDENSATE 4 3718 4 9/18" 118 MM 27 W16' 701 MM 2 i3M i 7 e tt'!- 3 11/16- 185 MM 94MM 23 1f2" 597 MM THROUGH THE BASE GAS (Y_C MODELS ON LYI THROUGH THE BASE ELECTRICAL —125 51fM • . 91618" 253 MM 192 RT- PRCO23 -EN Weights ble 160. Maximum unit & comer weights (lbs) and center of gravity dimensions (in.) - cooling models Maximum Model Unit Weights(a) Corner Weights(b) Center of Gravity (in.) Tons Mode Shipping Net A 6 C D Length Width 3 TSC036E 555 481 157 122 95 107 31 19 4 TSC048E 86 511 167 129 101 114 31 19 5 TSC060E 636 561 183 142 111 125 31 19 6 TSC072E 815 0 231 187 135 167 40 22 7Y1 TSC090E 834 739 235 196 140 168 40 22 716 TSC092E 992 849 147 252 96 42 22 8W TSC102E 1048 905 359 61 265 120 42 23 10 TSC120E 1123 1025 312 260 206 247 40 24 3 THC036E 614 544 163 144 125 33 19 4 THC048E 787 692 220 178 132 163 40 23 5 THC060E 841 746 241 193 139 17 39 22 6 THC072E 915 818 252 224 161 181 42 22 7% THC092E 1421 1227 346 330 269 282 49 28 8 THC102E 1436 1242 360 337 268 287 48 28 10 THC120E 1446 1252 355 334 268 285 48 28 (a) Weights are approximate. (b) Comer weights are given for information only. CENTER OF GRAVItY LENGTH CENTER OF GRAVITY WIDTH 0 CUITER OF GRAVITY Table 161. Maximum unit & comer weights (lbs) and center of gravity dimensions (in.) - gas/electric models Maximum Model Unit Weights(a) Comer Weights(b) Center of Gravity (in.) Tons Model No. Shipping Net A EI C 0 Length Width 5 3 YSC036E 607 3f) 165 137 95 134 31 19 4 YSC048E 638 563 175 145 101 142 31 19 5 YSC060E 688 613 190 158 110 155 31 19 6 YSC072E 936 793 304 146 219 124 41 23 7Y3 YSC090E 916 821 256 222 159 183 41 22 7Y: YSC092E 1042 899 366 160 265 108 42 22 8'h YSC102E 1096 953 371 173 277 132 42 23 continued on next page 208 RTPRCO23 -EN Weights -T • le 161. Maximum unit & comer weights (Ibs) and center of gravity dimensions (in.) - gas /electric models (continued) Maximum Model Umr Weights(a) Corner Weights(b) Center of Gravity (in.) Tons Model No. - • •ing Net A B C D Length Width 10 YSC120E 1221 123 337 292 229 264 41 23 3 YHC036E 676 606 178 162 126 139 33 19 4 YHC048E 858 763 238 200 148 176 40 23 5 YHC060E 917 822 261 218 56 187 40 22 6 YHC072E 997 900 274 250 180 96 42 22 81/2 YHC092E 1528 1334 373 368 295 299 50 28 10 YHC102E 1553 1359 387 375 294 303 49 28 10 YHC120E 1563 1369 386 379 299 305 49 2: (a) Weights are approximate. (b) Comer weights are given for information only. Table 162. Factory installed options (flops) /accessory net weights (Ibs)(8).(b) T /YSCO7E- T/YSC036E -060E T /YHC048E- 102E T/YHC092E- T/YHC036E 060E T /YHC072E T /YSC120E 120E Net Weight Net Weight Net Weight Net Weight Net Weight Accessory 3 -5 Tons 4 -5 Tons 6 -10 Tons 10 10 y Barometric Relief �) 10 10 10 10 Belt Drive Option (3 phase only) 31 31 Coll Guards Economizer Electric Heaters(c) Hinged Doors Manual Outside Air Damper Motorized Outside Air Damper Novar Control Oversized Motor Powered Convenience Outlet Powered Exhaust Reheat Coil Roof Curb Smoke Detector, Supply Smoke Detector, Return Stainless Steel Heat Exchangerid) Through the Base Electrical Through the Base Gas Unit Mounted Circuit Breaker Unit Mounted Disconnect 12 20 20 20 30 26 36 36 36 36 15 30 30 40 40 10 12 12 12 12 16 26 26 26 26 20 30 30 30 30 8 8 8 8 8 5 8 8 — — 38 38 38 38 50 40 40 80 80 80 15 25 — — 53 61 78 78 78 89 5 5 5 5 5 7 7 7 7 7 4 6 6 6 6 8 13 13 13 13 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 (a) Weights for options not listed are <5 Ibs. (b) Net weight should be added to unit weight when ordering factory- installed accessories_ (c) Applicable to Cooling units only. (d) Applicable to Gas/Electric units only. Add existing roof curb (56 Ibs) Add new adapter curb (119 Ibs) RT- PRCO23 -EN 209 ADAPTER CURB FOR TRANE TSC/THC/WSC/YSC/YHC036 -060A ADAPTERCLIBB EXISTINQJRANE UNIT SAHA30/40 & SFHA25/30 WITH FACTORY PLENUM AND CURB IMSD4tg: 1. REMOVE OLD A/C UNIT. 2. APPLY 1k' x 1 114" GASKETING. 3. INSTALL & SECURE ADAPTER CURB ON EXISTING CURB AS REQUIRED BY LOCAL BUILDING CODE. 4. APPLY 1/4" x 1 114' GASKETING ON ADAPTER CURB. 6. INSTALL & SECURE NEW A/C UNIT ON ADAPTER CURB AS REQUIRED BY LOCAL BUILDING CODE $TANDARDFEATURES; • HEAVY GA. GALV. STEEL CONSTRUCTION • FULLY INSULATED WITH 1" • 1.5 L8. DENSITY INSULATION • 114' x 1 114" GASKETING • SHIPPED FULLYASSEMBLED • SUPPLY AND RETURN DUCT CHAMBERS INCLUDED PRODUCT SUBMITTAL QUOTE # Model TC42ACAHA30 Manufacturers Equip Approved Date 1 PERMIT M0RD EO ?1O PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: M10 -085 DATE: 06/25/10 PROJECT NAME: DOUBLE TREE HOTEL SITE ADDRESS: 16500 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMEN S: din ivislon��, Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1,4 Comments: Incomplete n DUE DATE: 06/29/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07/27/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Prer Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MACDONALD /MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite /Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State WA Expiration Date 12/31/2010 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI*988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2010 Active MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor Unused General 12/31/1998 12/31/2001 Archived MACDOMR0760P MACDONALD MILLER RESIDENTIAL Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM*248J9 MACDONALD MILLER CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1 /2004 Expired LINFOAR980QG LINFORD AIR it REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Inactive DIVCOI*031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Relicensed Business Owner Information Name Role Effective Date Expiration Date TURLEY, DOUGLAS Chief Executive Officer 02/13/2008 TURLEY, DOUGLAS Chief Operating Officer 02/13/2008 WEBSTER, MARK E Member 05/14/2010 HOEL, STEPHANIE W Member 05/14/2010 https://fortress.wa.gov/lni/bbip/Print.aspx 07/13/2010 (1 0l 3 v rn 0 0 0 rn a Ir J: \730 \6438 DoubleTree Hotel Replace a N 0 0 N o 0 HVAC ABBREVIATIONS ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ABBV ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM FULL NAME EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK, LIQUID LINE MACDONALD- MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL ABBV OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER DUCT LEG END DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL 14x12 ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") 120W SOUNDLINE SHEETMETAL (1" LINING) 14x12SL CLEANROOM QUALITY DUCTWORK 14x12C SHEETMETAL WRAPPED W/ INSULATION (2 ") 14x12W BARE FLAT OVAL SHEETMETAL 14x120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 14x120W EXPOSED QUALITY SHEETMETAL 14x12Q DUCTBOARD (1" FIBERGLASS) 14x12DB EXAMPLE OF NEW 14x12 EXAMPLE OF NOT IN CONTRACT (NIC) 14x12 EXAMPLE OF DEMO FLEX DUCT EXAMPLE OF EXISTING 14X12 FLEX CONNECTOR EXISTING PACKAGED. G. AS /ELEC AIR CONDITIONING : UNIT.SCHEDULE UNIT NO. MFG & MODEL NO. AREA SERVED NOM TONS GAS HEAT MBH INPUT OUTPUT CFM ESP FAN HP OSA CFM SEER ELECTR CAL VOLT /PH MCA WT LBS dB NOTES AC-12 TRANE SFCA- 754-LB BANQUET RM 124 7.5 3000 460/3 1587 DEMO, 1,2 AC-14 TRANE SFHA- 304 -HE BANQUET RM 122 3 1200 460/3 593 DEMO, 1,2 NOTES: 1. REPLACE WITH NEW UNIT WITH LIKE TONNAGE. SEE PACKAGED GAS/ELEC AIR CONDITIONING UNIT SCHEDULE. 2. REUSE EXISTING POWER WIRING FOR REPLACEMENT UNIT. PACKAGEIIGAS /ELECAIR CONDITIONING UNIT SCHEDULE . UNIT NO. MFG & MODEL NO. AREA SERVED NOM TONS GAS HEAT MBH INPUT OUTPUT CFM ESP FAN HP OSA CFM SEER ELECTRICAL VOLT /PH MCA WT LBS dB NOTES AC -12 TRANE YSC090E4EMA018Y BANQUET RM 124 7.5 150 120 3000 0.5 1 11.2 460/3 19.5 1142 89 NEW, 1 -5 AC-14 TRANE YSC036E4EMA0047 BANQUET RM 122 3 80 64 1200 0.5 1 13 460/3 10.1 740 81 NEW, 1-4 NOTES: 1. USE EXISTING POWER WIRING. DISCONNECT AND RECONNECT ELECTRICAL SERVICE AND NEW DISCONNECT SWITCH BY M -M. 2. FACTORY 0 -100% ECONOMIZER WITH BAROMETRIC RELIEF. 3. R-410 REFRIGERANT. 4. SUMMIT CONTROL CARD, SENSORS, INTEGRATION WITH EXISTING BUILDING DDC SYSTEM AND PROGRAMMING BY M -M. 5. RETURN AIR SMOKE DETECTOR PROVIDED BY M -M. MOUNTING AND CONNECTING DETECTOR TO EXISTING WIRING BY M -M. WIRING TO FIRE ALARM PANEL BY OTHERS. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical „Er lumbing Gas Piping City of Tukwila B1 t DING D1VIS ON REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Rvv;sicns Will require a new plan submittal ad,,..ional p:'2 fzc HVAC GENERAL NOTES S 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 9. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 11. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC-2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 15. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 16. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 17. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. . CONTACT LIST ' TITLE PROJECT ENGINEER ACCOUNT MANAGER REFRIGERATION FOREMAN FITTING FOREMAN AIR BALANCE FIELD FOREMAN SHEET METAL FOREMAN ELECTRICAL FOREMAN DDC CONTROLS COORDINATOR NAME CHRIS LEE TOM MONTGOMERY DEAN GRASSER JASON ZEMBRYCKI RON LANDBERG DEAN GRASSER ED ADAMS BRIAN WHEELER COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 - 768 -4266 206 - 768 -3988 206 - 768 -4270 206 - 768 -3860 206 - 571 -2661 206 - 768 -4270 206 - 768 -3826 206 - 571 -2659 FAX NUMBER 206 - 768 -4267 206 - 768 -3989 206 - 768 -4271 206 - 768 -3861 206 - 768 -3992 206 - 768 -4271 SCOPE OF WORK REPLACE (2) PACKAGED GAS HEAT ROOFTOP UNITS WITH LIKE - FOR -LIKE TONNAGE REPLACEMENTS. INSTALL (2) CURB ADAPTERS. DISCONNECT AND RECONNECT POWER WIRING AND GAS SERVICE. . PROVIDE (1) RETURN AIR SMOKE DETECTOR. WIRING ON ROOF BY M - ?A WIRING TO FIRE ALARM PANEL BY OTHERS IF REQUIRED. PROVIDE AND INSTALL SUMMIT CONTROL CARDS, SENSORS, PROGRAMMING AND INTERGRATION WITH EXISTING BUILDING DDC SYSTEM. AIR BALANCE. INDEX . DRAWINGS EET NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01 S SITE MAP - HVAC TM2.02 TM3.01 ROOF PLAN - HVAC ELEVATIONS - HVAC .. ... .. ; LEGAL DESCRIPTION , . APN# 6437300020 LEGAL DESCRIPTION: CHA SOUTHCENTER LLC PROJECT LOCATION COPY Permit No.. WO --10V---; Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approve/y1 Copy and conditions is acknowledged: B . _ _"i /( tee- Y Date: .7 // //t) City Of lbkwila BUILDING DIVISION DAMPER SCHEDULE ; .. SYMBOL DESCRIPTION- POWERED NOTES SYMBOL DESCRIPTION -NON POWERED NOTES 1 1/2 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR 1,2 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL BLVD FSD -1 10 HORIZONTAL, 3 -V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 FD -1 • OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM, POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK GREENHECK DFD 150 TYPE A OR EQUAL. FSD 212 OR EQUAL. A++ + + + ++ . + + + + ++ + + + 4 + 4 + 4 + + + + + + 4 + 4 + + + 4 + + + + + + + + + + + + + + 4- + + + + + + + + 3, + + + + + + + + + + + + + 4- + + 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL I ER PKWY 1 1/2 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL 1,2 FD -2 ® OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V FSD -2 1 ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, STREAM, GREENHECK DFD 150 TYPE B OR EQUAL. GREENHECK FSD 312 OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL FD -3 © OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR 3 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR FSD -3 O3 HORIZONTAL, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 1,2 STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL FSD 231 OR EQUAL. FD -4 © OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR 3 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL 1,2 STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. FSD -4 O3 OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2 GREENHECK FSD 311 OR EQUAL. FD -5 ® TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE 1 1/2 HOUR TUNNEL CORRIDOR FIRE/SMOKE DAMPER: 1,2 LINK, GREENHECK DFD -110 OR EQUAL. FSD -5 1 LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V FD -4 O CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212 -1 OR EQUAL. ' BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100 BDD (HORIZONTAL) OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE/SMOKE DAMPER: LOW 1,2 FSD -6 1 VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V BAR BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) . , ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK OF SD 212 OR EQUAL. RUSKIN CBD2. NO SUBSTITUTE ALLOWED. VOLUME DAMPER: SHOP FABRICATED, W/LOCKING QUADRANT. SD -1 S SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. 1,2 SD -2 O SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. 1,2 MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK 3 MD -1 M VCD -23 OR EQUAL. REVIEWED FOR MD -2 M MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL O 4 CODE COMPLIANCE BLADES GREENHECK VCD -33 OR EQUAL. 4 . DOOMED SCD -1 SC SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY GREENHECK SMD 202 OR EQUAL. 1,2 JUL l 2u10 AV- SMOKE CONTROL MOTORIZED DAMPER: MEDIUM SCD -2 <> AIRFOIL BLA E, GREENHECK SMD 301 OR EQUAL. VELOCITY 1,2 City Of riwlla BUILDING niVlsIi1N NOTES: 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN /CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. DAMPER FAILS CLOSED DUCT LEG END DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL 14x12 ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") 120W SOUNDLINE SHEETMETAL (1" LINING) 14x12SL CLEANROOM QUALITY DUCTWORK 14x12C SHEETMETAL WRAPPED W/ INSULATION (2 ") 14x12W BARE FLAT OVAL SHEETMETAL 14x120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 14x120W EXPOSED QUALITY SHEETMETAL 14x12Q DUCTBOARD (1" FIBERGLASS) 14x12DB EXAMPLE OF NEW 14x12 EXAMPLE OF NOT IN CONTRACT (NIC) 14x12 EXAMPLE OF DEMO FLEX DUCT EXAMPLE OF EXISTING 14X12 FLEX CONNECTOR EXISTING PACKAGED. G. AS /ELEC AIR CONDITIONING : UNIT.SCHEDULE UNIT NO. MFG & MODEL NO. AREA SERVED NOM TONS GAS HEAT MBH INPUT OUTPUT CFM ESP FAN HP OSA CFM SEER ELECTR CAL VOLT /PH MCA WT LBS dB NOTES AC-12 TRANE SFCA- 754-LB BANQUET RM 124 7.5 3000 460/3 1587 DEMO, 1,2 AC-14 TRANE SFHA- 304 -HE BANQUET RM 122 3 1200 460/3 593 DEMO, 1,2 NOTES: 1. REPLACE WITH NEW UNIT WITH LIKE TONNAGE. SEE PACKAGED GAS/ELEC AIR CONDITIONING UNIT SCHEDULE. 2. REUSE EXISTING POWER WIRING FOR REPLACEMENT UNIT. PACKAGEIIGAS /ELECAIR CONDITIONING UNIT SCHEDULE . UNIT NO. MFG & MODEL NO. AREA SERVED NOM TONS GAS HEAT MBH INPUT OUTPUT CFM ESP FAN HP OSA CFM SEER ELECTRICAL VOLT /PH MCA WT LBS dB NOTES AC -12 TRANE YSC090E4EMA018Y BANQUET RM 124 7.5 150 120 3000 0.5 1 11.2 460/3 19.5 1142 89 NEW, 1 -5 AC-14 TRANE YSC036E4EMA0047 BANQUET RM 122 3 80 64 1200 0.5 1 13 460/3 10.1 740 81 NEW, 1-4 NOTES: 1. USE EXISTING POWER WIRING. DISCONNECT AND RECONNECT ELECTRICAL SERVICE AND NEW DISCONNECT SWITCH BY M -M. 2. FACTORY 0 -100% ECONOMIZER WITH BAROMETRIC RELIEF. 3. R-410 REFRIGERANT. 4. SUMMIT CONTROL CARD, SENSORS, INTEGRATION WITH EXISTING BUILDING DDC SYSTEM AND PROGRAMMING BY M -M. 5. RETURN AIR SMOKE DETECTOR PROVIDED BY M -M. MOUNTING AND CONNECTING DETECTOR TO EXISTING WIRING BY M -M. WIRING TO FIRE ALARM PANEL BY OTHERS. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical „Er lumbing Gas Piping City of Tukwila B1 t DING D1VIS ON REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Rvv;sicns Will require a new plan submittal ad,,..ional p:'2 fzc HVAC GENERAL NOTES S 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 9. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ". 11. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC-2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 15. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 16. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 17. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. . CONTACT LIST ' TITLE PROJECT ENGINEER ACCOUNT MANAGER REFRIGERATION FOREMAN FITTING FOREMAN AIR BALANCE FIELD FOREMAN SHEET METAL FOREMAN ELECTRICAL FOREMAN DDC CONTROLS COORDINATOR NAME CHRIS LEE TOM MONTGOMERY DEAN GRASSER JASON ZEMBRYCKI RON LANDBERG DEAN GRASSER ED ADAMS BRIAN WHEELER COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 - 768 -4266 206 - 768 -3988 206 - 768 -4270 206 - 768 -3860 206 - 571 -2661 206 - 768 -4270 206 - 768 -3826 206 - 571 -2659 FAX NUMBER 206 - 768 -4267 206 - 768 -3989 206 - 768 -4271 206 - 768 -3861 206 - 768 -3992 206 - 768 -4271 SCOPE OF WORK REPLACE (2) PACKAGED GAS HEAT ROOFTOP UNITS WITH LIKE - FOR -LIKE TONNAGE REPLACEMENTS. INSTALL (2) CURB ADAPTERS. DISCONNECT AND RECONNECT POWER WIRING AND GAS SERVICE. . PROVIDE (1) RETURN AIR SMOKE DETECTOR. WIRING ON ROOF BY M - ?A WIRING TO FIRE ALARM PANEL BY OTHERS IF REQUIRED. PROVIDE AND INSTALL SUMMIT CONTROL CARDS, SENSORS, PROGRAMMING AND INTERGRATION WITH EXISTING BUILDING DDC SYSTEM. AIR BALANCE. INDEX . DRAWINGS EET NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01 S SITE MAP - HVAC TM2.02 TM3.01 ROOF PLAN - HVAC ELEVATIONS - HVAC .. ... .. ; LEGAL DESCRIPTION , . APN# 6437300020 LEGAL DESCRIPTION: CHA SOUTHCENTER LLC PROJECT LOCATION COPY Permit No.. WO --10V---; Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approve/y1 Copy and conditions is acknowledged: B . _ _"i /( tee- Y Date: .7 // //t) City Of lbkwila BUILDING DIVISION CITY OFit�JIiWILA JUN 2 5 2010 PERMIT CENTER OSG co O 0 U co z 0 FACILITY SOLD 1 (.0 t- w co rn� < m co CD 03 (./) 0 v ca = E ccs, • < > CI) 12- 8 N N 0 ai 0 r- `17- d 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 121 I oh tD O 0 0 O! W D_ 111111 l< z W W Lu j-- Q O -i 11.Q W W�� w I- I-28 W Z� W J N =Q CO '- DD °J OHO 0� ENGINEER: C LEE CHECKED BY: B GEZON CAD: ISSUE DATE: P MILLER 06 -18 -10 MACDOFS980RU O Z o 0 M b) w CC a x w w Q 0 REVISIONS: W 0 REVISIONS: z 0 U z 0 U 0 LL" 0 W V J LAST REVISED: 06 -18 -10 DATE PLOTTED: 06 -18 -10 DRAWING NUMBER: D -1214- 7306438 -00 SHEET NUMBER: TM0.01 BLVD STRANDER A++ + + + ++ . + + + + ++ + + + 4 + 4 + 4 + + + + + + 4 + 4 + + + 4 + + + + + + + + + + + + + + 4- + + + + + + + + 3, + + + + + + + + + + + + + 4- + + I ER PKWY + + + + + S 168TH ST CITY OFit�JIiWILA JUN 2 5 2010 PERMIT CENTER OSG co O 0 U co z 0 FACILITY SOLD 1 (.0 t- w co rn� < m co CD 03 (./) 0 v ca = E ccs, • < > CI) 12- 8 N N 0 ai 0 r- `17- d 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 121 I oh tD O 0 0 O! W D_ 111111 l< z W W Lu j-- Q O -i 11.Q W W�� w I- I-28 W Z� W J N =Q CO '- DD °J OHO 0� ENGINEER: C LEE CHECKED BY: B GEZON CAD: ISSUE DATE: P MILLER 06 -18 -10 MACDOFS980RU O Z o 0 M b) w CC a x w w Q 0 REVISIONS: W 0 REVISIONS: z 0 U z 0 U 0 LL" 0 W V J LAST REVISED: 06 -18 -10 DATE PLOTTED: 06 -18 -10 DRAWING NUMBER: D -1214- 7306438 -00 SHEET NUMBER: TM0.01 J: \730 \6438 DoubleTree Hotel Replace RTU 267J04902/ 2620/9'04 PROJI- CT LOCAT 0\ 64J/J000 0 � 109' 262J049 J/ ,C 0 i 0 26)6049 02 0) N 64JL500020 AC-14 AC -12 262J0/9'28 00 N 1 47'-7" C 262,5049035 26704906,2 / / / REVIEWED FOR CODE COMPLIANCE APP! flV ED JUL 12 2010 City of Tukwila BUILDING DIvIcInM SOUND LEVEL UNIT : RTU -12 SOUND POWER LEVELS PER ARI 270 DATA PROVIDE BY MANUFACTURER = 89 dBA DISTANCE BETWEEN EQUIPMENT AND NEAREST RECEIVER = 226' ESTIMATED SOUND LEVEL AT RECEIVER = 45 dBA ZONING OF RECEIVING AREA = TUC (EDNA CLASS B COMMERCIAL) ZONING OF PROPERTY = TUC (EDNA CLASS B COMMERCIAL) ALLOWED NOISE LEVEL FOR NIGHT TIME CLASS B TO CLASS B ZONING = 60 dBA NOISE AT RECEIVER IS BELOW LEVELS ALLOWED BY 173-60 WAC. UNIT : RTU -14 SOUND POWER LEVELS PER ARI 270 DATA PROVIDE BY MANUFACTURER = 81 dBA DISTANCE BETWEEN EQUIPMENT AND NEAREST RECEIVER = 258' ESTIMATED SOUND LEVEL AT RECEIVER = 36 dBA ZONING OF RECEIVING AREA = TUC (EDNA CLASS B COMMERCIAL) ZONING OF PROPERTY = TUC (EDNA CLASS B COMMERCIAL) ALLOWED NOISE LEVEL FOR NIGHT TIME CLASS B TO CLASS B ZONING = 60 dBA NOISE AT RECEIVER IS BELOW LEVELS ALLOWED BY 173-60 WAC. M cmr�oF�u�° w JUN 2 5 2010 PERMIT CENTER 1 c O ,- 00 71 O W M O O LZ .macmiller.com 111 111 111 111 0 U 0_ w 1 l< WA Lic No: MACDOFS980RU 0 w cc a X W ENGINEER: C LEE CHECKED BY: B GEZON CAD: P MILLER w 0 REVISIONS: w 0 REVISIONS: Z 0 U U) Z 0 0 0 LL 0 W 0) 0) LAST REVISED: 06 -18 -10 DATE PLOTTED: 06 -18 -10 ISSUE DATE: 06 -18 -10 DRAWING NUMBER: D -1214- 7306438 -00 SHEET NUMBER: TM0.01 S J: \730 \6438 DoubleTree Hotel Replace RTU 0 AC -1 HV -1 EF -6 EF- 0 AC -14 REPLACE A/C UNIT AND INSTALL ADAPTER CURB, DISCONNECT AND RECONNECT GAS AND ELECTRICAL FM -1 1" AC -3 AC -12 o�—1" :r EF -5 0 34 4 3�4" AC -5 AC -14 AC -7 1 —Y" /— 4 0 EF -8 REPLACE A/C UNIT AND INSTALL ADAPTER CURB, DISCONNECT AND RECONNECT GAS AND ELECTRICAL, SEE STRUCTURAL CALCULATIONS FOR MOUNTING DETAILS EF -5 2" FM -2 /LThEVIEWED ZAR CODC� APPOVEC� JUL 12 2010 City of Tukwila BUILDING DnnSifM EF -7 0 2" f— GAS METER 3/4"0-\1 °N_ 1 2" f 3/4" O HV -1 r EF -12 0 HV -2 EF -8 9 10 11 l�� .macmiller.com 1 1 1 1 1 1 1 1 WA Lic No: MACDOFS980RU N z 0 N 1 1 1 1 1 1 1 1 Dc 1 1 1 1 1 1 1 °I W co 1 Q 0 t4(o.4b08.5 arroFn�SRu+ JUN 2 5 2010 PERMIT CENTER zAL 1/16" = 1' -0" 0 ENGINEER: C LEE CHECKED BY: B GEZON CAD: P MILLER DRAWING NUMBER: z 0 z 0 0 z 0 0 0 u_ 0 W 0) LAST REVISED: 06 -18 -10 DATE PLOTTED: 06 -18 -10 ISSUE DATE 06 -18 -10 D -1214- 7306438 -00 SHEET NUMBER: TM2.02 Friday, June 18, 2010 2:35:53 PM AC -12 r LOWER ROOF 0 cV GRADE EAST BUILDING ELEVATION SCALE: 1/16" = 1' -0" AC -14 AC -12 GRADE SOUTH BUILDING ELEVATION SCALE: 1/16" = 1' -0" REVIEWED FOR - CODE COMPLIANCE A PPPMED JUL 12 2010 City of Tukwila BUILDING nnnsinnt' M(O-O85 �co�� CITYOFTII u` JUN 2 5 2010 PERMIT CENTER a) 00 .7 ■5 O 0 -0 __J TO (9 C p 0 —I- oN- w0 rnr.t. Q dj 0 N fn 0 g o 0 t0 a) C <2. co Z ti 8 N N 0ai O 4_ MACDOFS980RU 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Ii1 0 REVISIONS: 01 I Qao 0 0 0 H m D_' IJ J D_ I I I I I I l< Z W J W0 Q OJ W ILI W�a w W °6zr LLJ� J(V =Q CO '— OF- ENGINEER: C LEE REVISIONS: Z 0 U rt Z 0 0 0 u_ 0 W LAST REVISED: 06 -18 -10 CHECKED BY: DATE PLOTTED: B GEZON 06 -18 -10 CAD: ISSUE DATE: P MILLER 06 -18 -10 DRAWING NUMBER: D -1214- 7306438 -00 SHEET NUMBER: TM3.01