Permit M10-094 - JC PENNEY - SEPHORA
JC PENNEY, SEPHORA 1249 SOUTHCENTER MALL M10 -094 Parcel No.: Address: City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspectio n Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT 9202470010 1249 SOUTHCENTER MALL TURIN Project Name: JC PENNEY, SEPHORA Permit Number: M10 -094 Issue Date: 07/22/2010 Permit Expires On: 01/18/2011 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 TED HUNT 301 PORTER WY , MILTON WA 98354 TEDH @GROUPMCS.COM Contractor: Name: MECHANICAL & CONTROL SRVCS INC Address: 301 PORTER WAY , MILTON WA 98354 Contractor License No: MECHACS962BT Phone: 253 - 926 -9777 Phone: 253 926 -9777 Expiration Date: 02/26/2012 DESCRIPTION OF WORK: INSTALL OWNER PROVIDED VAV BOXES FURNISHED BY OWNER, FURNISH & INSTALL RETURN GRILLES & DIFFUSERS, CLEAN & REINSTALL EXHAUST FANS, INSTALL NEW DUCTWORK, INSTALL NEW DUCT & DAMPER IN STOCK SPACE, INSTALL VAV SENSORS Value of Mechanical: $18,577.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: L.311 Fees Collected: $374.31 International Mechanical Code Edition: 2009 Date: s-7-1:7)-0)-- b I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I a authorized to sign and obtain this mechanical permit. Signature. Print Nam This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10-094 Printed: 07 -22 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 9202470010 Address: 1249 SOUTHCENTER MALL TUKW Suite No: Tenant: JC PENNEY, SEPHORA Permit Number: M10 -094 Status: ISSUED Applied Date: 07/19/2010 Issue Date: 07/22/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10-094 Printed: 07 -22 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any construction or the performance of work. Signature: Print Name: of law and ordinances governing other work or local laws regulating doc: Cond -10/06 M10 -094 Printed: 07 -22 -2010 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us • Building Permit No. Mechanical Permit No. M 10— 0 q y Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: King Co Assessor's Tax No.: c) %- 00 /0 la-H9 So{,.., Tenant Name: ye, P 811 IA ri.Nti Property Owners Name: SG P v -r_J Mailing Address:Jsn j j Suite Number: c 69 , Floor: New Tenant: ❑ Yes VL.No City CONTACT PERSON — who do we contact when your permit is ready to be issued Name: ma 140y4 4 Mailing Address:30 1 d E -Mail Address: le.ditIc rat) ,Q rt-IcS c.Dvv) Day Telephone: n5 3 9 - 9 77 ) rn i ti)P 983s I City State Zip Fax Number: oZs3 6 - 9zaas GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name:_tx 'Op CYS Cdnf3 + Cr'n Mailing Address: 63 q t, Pty d u c Contact Person: (h k >° m E -Mail Address: Contractor Registration Number: S ;ty� ►, N.S 1227- `,Z83 Day Telephone: 5 999 Fax Number: 5 $6 93 9` 9 OCS Expiration Date: ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: V a..dct_ ri-$Se, s Mailing Address: °L30 (,�,Cf �i riv7Y) c7tc. CI% t C.C� go 6o6c4 City State Zip Contact Person: Day Telephone: 31-a. 33 Fax Number: at - 9 ?9 E -Mail Address: ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: State Contact Person: E -Mail Address: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh City Zip Day Telephone: Fax Number: Page 1 of 6 • MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: tY1 v_fiF1GY 1/\ \ «'Q 4— (' o?Y\ �rv� Mailing Address: 3e) 1 PG r•40--,L) CA_Z A� Contact Person: °mod 14,-, +- �\JJ E -Mail Address: fe_d-in4j,, t— Up mCf , Corn Contractor Registration Number: n1 ACS B 7 , rn �' I+r-m City "Tr.c_ Cel State Zip Day Telephone: ta53 °l -O --c7)-7) Fax Number: ",L' S3 9a -- 9& a , Expiration Date: 13e, ) 11 Valuation of Mechanical work (contractor's bid price): $ $ } 5`% 7 Scope of Work (please provide detailed information): lh5- 5-Frei p r5U RIO a V- -v bent 45' cum IShcd ID/ cwn�� Fv�h ►611 d, r,: ..1l r vr►� fr,Ii�°s cFuS�rs, dkrcx\ d- re_ thS -� �Y- l ctu, Fe-, ,n.s l i In 5 n A II d-L r k i ►, 5�'�I 1 h iv 4 t' 01.-- d. Anne ► t h S p�t�� \ v, 5.4.4_t I 1/ ►4-V Bob Ste,,, se, rLS Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... Fuel Type: Electric ❑ Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:Wpplications\Forms- Applications On Line\2010 Applications \ 7-2010 - Permit Apphcatton.doc Revised: 7 -2010 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU Signature: Print Name: AGENT: Mailing Address: Date: 7 l c3 / Day Telephone: °p1 S 3 9 a6-9-1--7 InLL_uz/ L t X64 Rg3Sy City State Zip Date Application Accepted: -7,,,, I G _ r D Date Application Expires: 1'1 q_ / / Staff Initials: H:\Applicanons\Forms- Applications On Lme\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bb Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 9202470010 Permit Number: M10 -094 Address: 1249 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/19/2010 Applicant: JC PENNEY, SEPHORA Issue Date: Receipt No.: R10 -01342 Initials: User ID: Payee: WER 1655 Payment Amount: $374.31 Payment Date: 07/19/2010 01:39 PM Balance: $0.00 MECHANICAL & CONTROL SERVICES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 23576 374.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 299.45 000.345.830 74.86 Total: $374.31 doc: Receiot -06 Printed: 07 -19 -2010 ill INSPECTION RECORD Retain a copy with permit INSPECT.* NO. PERMIT NQ. CITY OF TUKWILA BUILDING DIVISION I* 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proje : PeNNWc -( Type of Inspection: r: rNA ( Ad r ss: Zak- Ci 01A 1 I Date Called: Special Instructions: Date Wanted: Z 7 I 0 a.m. p.m. Requester: Phone No: 171.4zproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspe or: Date' AA .y .�. - 2 7— 10 $60.0 1 REINSPECTIO FEE EQUIRED. Pri r to inspection, fee must be paid . 6300 Southcenter Blvd., Suite 100. ll to schedule reinspection. Rec - • No.. Date: 4s INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PERMIT NO. Projec o Typhof Inspectir j ic(e Address: e Date Ca c.-T- " Special Instructions: Date Wanted: S� .' C --( a U a.m. P.m. Requester: Pho2 33 - 3 1 1 —5.3 24 • d1 Approved per applicable codes} ',, ❑ Corrections required prior to approval. 4$ COMMENTS: AAA"-, I Date: 0 REINSPECTION FE REQUIRED. Prier to inspection, fee must be at 6300 Southcenter B vd., Suite 100. all to schedule reinspection. tNo.: Date: • • PE 16 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -094 DATE: 07 -19 -10 PROJECT NAME: JC PENNEY - SEPHORA SITE ADDRESS: 1249 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 4 Building Division Public Works ,91A N14 Fire Prevdntion Structural Planning Division Permit Coordinator 11 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07 -20-10 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -17-10 Approved ❑ Approved with Conditions K Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Prlter Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with L &1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information • Name MECHANICAL & CONTROL SRVCS INC UBI No. 602338440 Phone 2539269777 Status Active Address 301 Porter Way License No. MECHACS962BT Suite /Apt. License Type Construction Contractor City Milton Effective Date 1/30/2004 State WA Expiration Date 2/26/2012 Zip 98354 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ARASSI'981K0 ARAS SYSTEMS INC Construction Contractor General Unused 5/20/2002 5/20/2010 Expired Business Owner Information Name Role Effective Date Expiration Date HULL, TRAVIS EDWARD President 02/26/2010 Bond Amount HUNT, TED LAMOND Vice President 02/26/2010 6676648 DICKSON, PAUL Treasurer 01/30/2004 02/26/2010 GROVER, HAROLD Vice President 01/30/2004 02/26/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIRST NATIONAL INS CO OF AMERICA 6676648 02/06/2010 Until Cancelled $12,000.00 12/30/2009 3 DEVELOPERS SURETY & INDEM CO 791184C 02/06/2008 Until Cancelled 02/23/2010 $12,000.00 02/10/2008 2 DEVELOPERS SURETY & IND 572212C 01/23/2006 02/06/2008 02/20/2010 $12,000.0002/27 /2006 1 DEVELOPERS SURETY & INDEM CO 572212C 02/01/2004 01/23/2006 02/20/2010 $6,000.0001 /30/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE & CASUALTY CO BKA53709396 01/23/2010 01/23/2011 $1,000,000.00 01/22/2010 2 OHIO CAS INS BKW53709396 01/23/2008 01/23/2010 $1,000,000.00 01/23/2008 1 FIRST NATIONAL INSURANCE CO 01CG492168 3 01/23/2004 01/23/2008 $1,000,000.00 01/19/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/22/2010 APPROVED TEST AND BALANCE (TAB) FIRMS CONTRACTOR CONTACT EMAIL PHONE STATES COVERED FUNCTION FAN MANUFACTURER/ NOTES MARK ENGINEERED AIR BALANCE GORDON BLACK GBIack®eabcoinc.com (972)818 -9000 OK, TX RS ANALYSIS JIM TEGLEY jtegley ®rsana!ysis.com (510)715 -8322 ND, NE, SD, KS, AK, AZ, CA, CO, ID, NM, WA, WY, UT, NV, OR MT THE PHOENIX AGENCY STEVE YOUNG steve .young©thephoenixagency.com (813)908- 7701 FL, GA, NC, SC, MS, AL, TN, LA, KY, AR, IA, IL, IN MN, WI, WV, VA, MO THOMAS -YOUNG AND ASSOCIATES, INC BILL THOMAS bthomas ®thomasyoungassociates.com (508)748 -0204 MA, CT, RI, NH, VT, ME, NY, PA, NJ, DE, MD, MI, OH NOTES: 1. GENERAL CONTRACTOR SHALL HIRE THE SERVICES OF A JCPENNEY APPROVED TAB AGENT LISTED IN THIS SCHEDULE. ■ CFM ROUND SHOE DUCT TAP MATCH BOX INLET SIZE PROVIDE FLEX DUCT CONNECTION ON ALL BOXES. PRIMARY AIR INLET DISCONNECT AND CONTROL PANEL SECONDARY AIR INLET. REMOVE FILTER AND DUCT TO SALES FLOOR CEILING SIZE DUCTWORK FOR FULL FAN FLOW / AN- / FAN POWERED / MIXING BOX TO DIFFUSERS A = MINIMUM OF 10' -0" FROM FITTING TO FIRST TAP. FILE COPY Permit No. ti 1v' Qqa( Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and co . ions is acknowledged: B Date: NOTES: 1. MAXIMUM NOISE LEVEL NC OF 35 IN ALL FREQUENCY BANDS. 2. MAXIMUM BOX TOTAL PRESSURE DROP + 0.25 IN. WATER GAUGE FOR FULL VAV SYSTEMS. 3. BOXES SHALL BE ELECTRONICALLY CONTROLLED BY CONTROLLERS AND SENSORS FURNISHED AND INSTALLED BY THE E.M.S. MANUFACTURER. 4. BRANCH DUCTWORK AIR VELOCITY TO, AND INCLUDING VAV BOXES SHALL BE LIMITED TO 2,000 FPM FOR FULL VAV SYSTEMS. DOWNSTREAM DUCTWORK SHALL BE DESIGNED AT AIR PRESSURE DROP OF 0.12 INCH WATER PER 100 FT. DUCT. 5. ON CONSTANT VOLUME SYSTEMS AND SINGLE ZONE VAV SYSTEM WHERE VAV BOXES ARE USED IN OFFICES, FITTING ROOMS, ETC., BRANCH DUCTWORK, INCLUDING VAV INLETS SHALL BE DESIGNED AT AN AIR PRESSURE DROP OF 0.12 INCH w.g. PER 100 FOOT OF DUCT AND MAXIMUM BOX PRESSURE DROP SHALL BE 0.05" INCH w.g. 6. THE SERIES FAN POWERED BOX (FPB) SHALL MAINTAIN VENTILATION AND COOLING REQUIREMENTS IN AREA SHOWN ON THE PLANS FOR INDEPENDENT ZONE CONTROL THIS DEVICE MAY BE ELECTRICALLY OR ELECTRONICALLY CONTROLLED. 7. THE CONTROL SEQUENCE SHALL PROVIDE CONSTANT FAN POWERED PRIMARY AIR CONTROL. THE UNIT FAN DRAWS EITHER DRAWS COLD PRIMARY AIR OR RETURN AIR TO SATISFY THE LOAD. WHEN THE PRIMARY SYSTEM IS FAILED, OR WHEN WARM PRIMARY AIR IS SENSED BY AN ELECTRONIC SENSOR, THE PRIMARY AIR VALVE WILL CLOSE WHEN THE BOX IS IN COOLING MODE. BOX SHALL INDEPENDENTLY SELECT HEATING AND COOLING MODE BASED ON THE ZONE TEMPERATURE. FAN POWERED BOX DETAIL SCALE: NONE ///> % J City Of Tlukwila BUILDING DIVISION AIR DEVICE SCHEDULE v SERIES FAN POWER BOX (FPB) SCHEDULE FOR CONSTANT VOLUME OR SINGLE ZONE SYSTEMS ONLY FRAME SIZE OBD FINISH VAV PRIMARY AIR FUNCTION FAN MANUFACTURER/ NOTES MARK TYPE SERVES MIN. COOLING MAX. COOLING INLET SIZE MAX. P.D. CFM AIR BALANCE, Inc. MAX HP V V/PH/HZ MAX. SIZE MODEL 35' FIXED BLADE MARK TITUS 350RL SERVES CFM CFM (IN) IN W.G. CFM WHITE E.S.P. HP V /PH /HZ N C SIZE 12 NOTES 1690 0.50 1/2 277/1/60 22 05SQ TRANE VSEF 1 -9 FPB -2 6 "0 SEPHORA 0 1690 FPB -1 0.05. SEPHORA 0 1690. 16 0.05 1690 05SQ 0.50 1/2 277/1/60 22 06SQ TRANE VSEF 1 -9 FPB -2 851 -1000 SEPHORA 0 1690 16 0.05 1690 4. 24V CONTROL TRANSFORMER ENERGIZED THROUGH SINGLE POINT POWER CONNECTION 0.50 1/2 277/1/60 22 06SQ TRANE VSEF 1 -9 NOTES: 1. _ CONTRACT MATT LASSEN AT 972 -406 -3643 IN THE DALLAS TRANE OFFICE FOR BOX 6. IN STORES WITHOUT A NOVAR OR TRANE EMS SYSTEM THE UNIT WILL BE SHIPPED IN STAND ALONE AND CONTROLS. OPERATION CONFIGURATION AND THE UNIT WILL BE SHIPPED WITH A SENSOR WITH ADJUSTABLE THUMB WHEEL 2. FAN CFM = MAX: COOLING CFM. AND INLET TEMPERATURE SENOR. BOTH TO BE INSTALLED AND WIRED BY THE MECHANICAL CONTRACTOR. ` 3. HEATING /COOLING AUTO CHANGEOVER CONTROL BASED ON PRIMARY AIR 7. FOR STORES WITH A NOVAR OR TRANE EMS SYSTEM CONTROLS WIRING AND SENSORS SUPPLIED BY TEMPERATURE ONLY CONTROLS VENDOR AND CONTRACTOR SHALL REQUEST THIS PRICE WITH THE FAN POWERED BOX. �� 4. 24V CONTROL TRANSFORMER ENERGIZED THROUGH SINGLE POINT POWER CONNECTION 8. MECHANICAL CONTRACTOR TO PROVIDE START -UP FOR FPB: a o 0 WITH LOCAL FUSED DISCONNECT. 9. NO FILTER ON THE RETURN AIR OPENING. •• 5. FACTORY INSTALLED LON DDC CONTROLLER. o o AIR DEVICE SCHEDULE SERIES FAN POWER BOX (FPB) SCHEDULE FOR FULL VAV SYSTEMS ONLY FRAME SIZE OBD FINISH VAV PRIMARY AIR FUNCTION FAN MANUFACTURER/ MODEL NOTES MARK TYPE SERVES MIN. COOLING CFM MAX. COOLING CFM INLET SIZE (IN) MAX. P.D. IN. W.G. CFM AIR BALANCE, Inc. MAX E.S.P. HP V V/PH/HZ MAX. N.C. SIZE WHITE 35' FIXED BLADE NON- SUPPLY TITUS 350RL NOTE 3 (U.N.O.) 2,4 LAY -IN CEILINGS J 16x16 NO WHITE FPB -1 SUPPLY SEPHORA 0 1690 12 0.05 1690 0.50 1/2 277/1/60 22 05SQ TRANE VSEF 1 -9 FPB -2 6 "0 SEPHORA 0 1690 12 0.05. 1690 0.50 1/2 277/1/60 22 05SQ TRANE VSEF 1 -9 NOTES: 1. CONTRACT MATT LASSEN AT 972 - 406 -3643 IN THE DALLAS TRANE OFFICE FOR BOX 6. N STORES WITHOUT A NOVAR OR TRANE EMS SYSTEM THE UNIT WILL BE SHIPPED IN STAND ALONE AND CONTROLS. OPERATION CONFIGURATION AND THE UNIT WILL BE SHIPPED WITH A SENSOR WITH ADJUSTABLE THUMB WHEEL 851 -1000 2. FAN CFM = MAX. COOLING CFM. AND INLET TEMPERATURE SENOR. BOTH TO BE INSTALLED AND WIRED BY THE MECHANICAL CONTRACTOR. 3. HEATING /COOLING AUTO CHANGEOVER CONTROL BASED ON PRIMARY AIR TEMPERATURE 7. FOR STORES WITH A NOVAR OR TRANE EMS SYSTEM CONTROLS WIRING AND SENSORS SUPPLIED BY ONLY. CONTROLS VENDOR AND CONTRACTOR SHALL REQUEST THIS PRICE WITH THE FAN POWERED BOX. 4. 24V CONTROL TRANSFORMER ENERGIZED THROUGH SINGLE POINT POWER CONNECTION 8. MECHANICAL CONTRACTOR TO PROVIDE START -UP FOR FPB. WITH LOCAL FUSED DISCONNECT. 9. NO FILTER ON THE RETURN AIR OPENING. _ 5. FACTORY INSTALLED LON DDC CONTROLLER. AIR DEVICE SCHEDULE MARK FRAME SIZE OBD FINISH THROW FUNCTION MANUFACTURER /MODEL NECK SIZE NOTES LOCATION TYPE �-- MARK (SEE SCHEDULE) �- CFM 2 H AES, Inc. GREENHECK YOUNG REGULATOR RUSKIN AIR BALANCE, Inc. NOTES . C 24x24 NO WHITE 35' FIXED BLADE NON- SUPPLY TITUS 350RL NOTE 3 (U.N.O.) 2,4 LAY -IN CEILINGS J 16x16 NO WHITE ADJUSTABLE SUPPLY TITUS 300RS NOTE 1 2,5,6 SEPHORA AREA NOTES: 1. 2. CONTRACTOR TO COORDINATE FRAME STYLE WITH EXISTING CONDITIONS. MARK 'A' NECK SIZES NECK SIZE MAX. CFM 3. 22 "x 22" (U.N.0) 6 "0 0 -100 4. 1" WIDE FRAME. 1 8 "o 101 -225 5. SUPPLY GRILLES IN SEPHORA AREA SHALL BE PROVIDED WITH DUCTED BOOT. (ADAPTOR) 10 "O 226 -400 6. FRAME 24x24 MODULE TYPE 3 12 "0 401 -650 ®IL_Hamm 14 "0 651 -850 16 "0 851 -1000 _�,I SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical llectricai QrriIumbing [was Piping City of Tukwila BUILDING DIVISION, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PERIMETER OF THE SEPHORA SPACE EQUIPMENT VOLUME BALANCING DAMPER SCHEDULE MARK (SEE SCHEDULE) RTU EQUIPMENT NUMBER AIR DEVICE No. OF AIR DEVICES TYPE �-- MARK (SEE SCHEDULE) �- CFM 2 H AES, Inc. GREENHECK YOUNG REGULATOR RUSKIN AIR BALANCE, Inc. NOTES . ......, - -6. 1 ROUND WMVCD MBDR -50 5020 -R WMRS25 AC -112 1 -9 NOTES: 1. 2. 3. 4. 5. RECTANGULAR DAMPERS ARE OPPOSED BLADE. 6. DAMPER SHALL HAVE 12" FLAGGING ATTACHED TO THE QUADRANT HANDLE. DAMPERS TO BE SUPPLIED WITH A MINIMUM 1 -1/2" STANDOFF BRACKET FOR QUADRANT HANDLE. 7. DAMPER SHALL BE LEFT IN THE WIDE OPEN POSITION PRIOR TO UNIT STARTUP AND DAMPERS TO BE SUPPLIED WITH 3/8" AXLE SHAFTS. BALANCING. DAMPERS TO BE SUPPLIED WITH LOCKING QUADRANT HANDLES (NO FRICTION LOCKS ALLOWED). 8. DAMPERS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION AT ALL BRANCH DUCTS, DUCT DAMPER POSITION SHALL BE INDICATED ON THE QUADRANT HANDLE. SPLITS AND TO THE LAST AIR DEVICE AT THE END OF THE LINE WHETHER OR NOT INDICATED ON THE DRAWINGS. ACCESS PANELS OR REMOTE DAMPER OPERATORS SHALL BE PROVIDED IN AREAS OF HARD CEILINGS WHEN THE DAMPERS CAN NOT BE LOCATED IN AN ACCESSIBLE CEILING AREA. 9. NO SUBSTITUTIONS. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical llectricai QrriIumbing [was Piping City of Tukwila BUILDING DIVISION, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PERIMETER OF THE SEPHORA SPACE SEPHORA MECHANICAL DETAIL SCALE: 1/8" = 1' -0" D FO1R PLIANCE VED 2010 kw.ila: IVIS IN DUCTWORK BETWEEN ETURN SEPHORA MECHANICAL NOTES HEATING, VENTILATING & AIR CONDITIONING SEPHORA AREA 1. THE GENERAL AND THE MECHANICAL CONTRACTOR SHALL ERIFY THE DUCT SYSTEM THAT WILL BE UTILIZED TO SERVE THE SEPHORA AREA, AND REPORT TO JCPENNEY WHAT TYPE OF SYSTEM IT IS DUCTED FROM ALONG WITH WHETHER THE UNIT THAT WILL SERVE THE SEPHORA AREA IS A CONSTANT VOLUME, VARIABLE AIR VOLUME, OR A UNIT RETROFITTED WITH A VARIABLE FREQUENCY DRIVE AND REPORT FINDINGS TO THE JCPENNEY PROJECT MANAGER. THESE FINDING WILL DETERMINE THE TYPE AND SIZE OF FAN POWERED MIXING BOXES. 2. REFERENCE THE SEPHORA MECHANICAL LAYOUT AND DETAIL ON THIS SHEET FOR AN EXAMPLE OF ALL SEPHORA DUCTWORK, DIFFUSERS AND CONTROLS. CONTRACTOR SHALL MODIFY THE HVAC LAYOUT FOR THE SPECIFIC PROJECT. 3. THE CONTRACTOR SHALL REMOVE THE EXISTING SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLES CURRENTLY INSTALLED WITHIN THE SEPHORA AREA AND PROPERLY SEAL AND CAP THE EXISTING DUCTWORK. IF REQUIRED, RELOCATE THE EXISTING SUPPLY AIR DIFFUSERS TO PROVIDE THE PROPER AIR FLOW TO THOSE PORTIONS OF THE SALES FLOOR ADJACENT TO THE SEPHORA AREA. 4. FAN POWERED BOXES (FPB) • THE CONTRACTOR SHALL FURNISH AND INSTALL TWO CONSTANT VOLUME (SERIES) FAN POWERED MIXING BOXES TO PROVIDE CONDITIONED AIR TO THE SEPHORA AREA. THE FAN POWERED BOXES SHALL BE SELECTED BASED ON THE TYPE OF AIR DISTRIBUTION SYSTEM IN THE STORE AND THE FPB SCHEDULES. • THERE IS A 7 WEEK LEAD TIME ON THESE BOXES. ORDERS SHOULD BE PLACED AS SOON AS THE PROJECT IS AWARDED TO AVOID QUICK -SHIP CHARGES. • 'THE CONTRACTOR SHALL PURCHASE THE FAN POWERED MIXING BOXES FROM TRANE, ALONG WITH HIRING THE SERVICES OF THE TRANE COMPANY TO CONTROL THE FAN POWERED MIXING BOXES THROUGH THE EXISTING ENERGY MANAGEMENT SYSTEM. CONTACT MATT LASSEN 972 -406 -3643 TO PURCHASE THE EQUIPMENT AND ARRANGE THE CONTROL WORK. COPY JCPENNEY'S BRENDAN SWEENEY, BJSWEENE @JCPENNEY.COM ON ALL CONTROL WORK REQUESTS. 5. DUCTWORK • PRIMARY SUPPLY AIR TO THE FAN POWERED MIXING BOXES SHALL BE DUCTED VIA SHEETMETAL DUCTWORK FROM THE NEAREST SUFFICIENTLY SIZED DUCT MAINS SERVING THE MAIN SALES FLOOR THAT CAN BE UTILIZE WITHOUT ADVERSELY AFFECTING THE QUANTITY OF AIR DOWNSTREAM OF THE NEW DUCT TAKEOFFS. • THE CONTRACTOR SHALL PROVIDE THE JCPENNEY PROJECT MANAGER AND THE TEST AND BALANCE CONTRACTOR WITH MECHANICAL DRAWINGS INDICATING THE LOCATION OF THE FAN POWERED BOXES, SUPPLY AIR REGISTERS, RETURN AIR GRILLES, DUCT LAYOUT, NEW DUCTWORK SIZING ALONG WITH THE SIZING OF EXISTING DUCT MAINS INCLUDING THE LOCATION OF THE TIE IN POINTS OF THE NEW DUCTS SERVING THE FAN POWERED MIXING BOXES. • SECONDARY AIR TO THE FAN POWERED MIXING BOXES SHALL BE SUPPLIED THROUGH 24° X 24" WHITE 35' FIXED BLADE GRILLES (TITUS 350 RL) LOCATED IN THE MAIN SALES AREA CEILING 20' - 0" FROM THE SEPHORA AREA AND DUCTED TO THE FAN POWERED MIXING BOXES VIA SHEETMETAL DUCTWORK. • THE CONTRACTOR SHALL FURNISH AND INSTALL SIX NEW 16" x 16" TITUS 300 RS DOUBLE DEFLECTION SUPPLY AIR REGISTERS WITH 24" X 24" TYPE 3 LAY IN PANELS SET AT 22 -1/2 ' DEFLECTION IN ALL 4 DIRECTIONS. PROVIDE AN INSULATED SHEETMETAL PLENUM BOX ABOVE EACH REGISTER. THREE REGISTERS SHALL BE CONNECTED DOWNSTREAM OF EACH FAN POWERED MIXING BOX. SEE TYPICAL LAYOUT FOR LOCATIONS. • FURNISH AND INSTALL SIX NEW 24" X 24" WHITE 35" FIXED BLADE RETURN AIR GRILLES WITH 1" WIDE FRAME (TITUS 350 RL). SEE TYPICAL LAYOUT FOR LOCATIONS. • COORDINATE THE LAYOUT OF THE NEW SUPPLY AIR REGISTERS AND RETURN AIR GRILLES WITH THE LIGHTING, SPRINKLER HEADS AND OTHER CEILING MOUNTED DEVICES. ADJUST THE LOCATION OF THE REGISTERS AND GRILLES AS REQUIRED TO AVOID CONFLICTS. • NEW DUCTWORK SHALL BE OF SHEET METAL CONSTRUCTION SIZED FOR A MAXIMUM .12" OF FRICTION. A MAXIMUM OF 8' -0" OF FLEXIBLE DUCTWORK IS PERMITTED BETWEEN THE SHEETMETAL DUCTWORK AND THE PLENUM BOX LOCATED ABOVE THE SUPPLY AIR REGISTERS. ALL DUCTWORK IS TO BE CONSTRUCTED AND INSTALLED PER SMACNA STANDARDS. • THE CONTRACTOR SHALL FURNISH AND INSTALL BALANCING DAMPERS IN ALL BRANCH DUCT TAKEOFFS TO THE REGISTERS SERVING THE SEPHORA AREA. BALANCING DAMPERS SHALL NOT BE INSTALLED IN THE TAP TO THE FAN POWERED BOX. • THE CONTRACTOR SHALL FURNISH AND INSTALL DOUBLE THICKNESS TURNING VANES IN ALL 90' DUCT ELBOWS. • ALL NEW DUCTWORK IS TO BE PROVIDED WITH EXTERIOR DUCT WRAP, IF THE EXISTING DUCTWORK SERVING THAT FLOOR IS INSULATED. 6. TEST AND BALANCE (TAB) • THE GENERAL CONTRACTOR SHALL HIRE THE SERVICES OF A JCPENNEY APPROVED TAB / COMMISSIONING AGENT TO BALANCE AND COMMISSION THE NEW FAN POWERED MIXING BOXES AND REGISTERS SERVING THE SEPHORA AREA. COMMISSIONING AGENT CONTACT INFORMATION IS AS SCHEDULED. • THE GENERAL CONTRACTOR SHALL PROVIDE MECHANICAL DRAWINGS TO THE TEST AND BALANCE AGENT PRIOR TO THEIR ARRIVAL AT THE SITE. • THE TAB MUST BE COMPLETED 4 WEEKS PRIOR TO THE OPENING DATE. ALL PUNCHLIST ITEMS MUST BE COMPLETED PRIOR TO THE OPENING DATE. • ALL TAB REPORTS SHALL BE SENT FROM THE TAB TO THE CONTRACTOR AND TO JCPENNEY PROJECT MANAGER, RICHARD MARNIK AT 6501 LEGACY DR., MAIL STOP 2111, PLANO TX 75024. REPORTS MUST BE DELIVERED WITHIN THREE WEEKS AFTER OF THE COMPLETION OF TAB PHASE. 7. ALL FAN POWERED BOXES OR OTHER MECHANICAL EQUIPMENT INSTALLED UNDER THIS SCOPE OF WORK SHALL BE PROVIDED WITH ELECTRICAL POWER THROUGH A NEW DEDICATED UNCONTROLLED POWER CIRCUITS. THIS ALSO INCLUDES 120V POWER TO ANY NEW ENERGY MANAGEMENT SYSTEM DEVICES REQUIRED TO COMPLETE THIS SCOPE OF WORK. NO NEW MECHANICAL EQUIPMENT SHALL BE SERVED OFF EXISTING CIRCUITS ALSO SERVING LIGHTING. 8. ALL NEW EQUIPMENT AND DUCTWORK SHALL BE SUPPORTED FROM STRUCTURAL BUILDING STEEL. SUPPORTING FROM THE DECK ABOVE OR FROM OTHER TRADES IS NOT PERMITTED. STOCK SPACE 1. THE CONTRACTOR SHALL FURNISH AND INSTALL A NEW DUCT AND SUPPLY AIR REGISTER WITH OPPOSED BLADE DAMPER (TITUS 300 RS) IF ONE IS NOT PRESENT WITHIN THE CONFINES OF THE SEPHORA STOCK SPACE SO AS TO MAINTAIN A MAXIMUM SPACE TEMPERATURE OF 78'. 2. IF THE STOCK SPACE IS FULLY ENCLOSED WITH SHEETROCK, THE CONTRACTOR MUST PROVIDE FOR ADEQUATE RETURN AIR OUT OF THE SPACE. 3. THE CONTRACTOR SHALL ADJUST THE SETPOINT OF EXISTING UNIT HEATERS OR OTHER TYPE OF EXISTING HEATING DEVICES LOCATED IN THE VICINITY OF THE SEPHORA STOCK SPACE TO 45'. FIRE PROTECTION 1. THE EXISTING SPRINKLER HEAD LAYOUT SHALL BE MODIFIED AS REQUIRED SO TO PROVIDE PROPER COVERAGE / CLEARANCE REQUIREMENTS BASED ON THE LAYOUT. OF THE SEPHORA SALES AND PERIMETER FIXTURING. (Rev. 5/18/10) REVISIONS A 12/03/2009 - DM ISSUED FOR SE REVIEW AND BIDDING 05/19/2010 - DM RELEASED AS DB w 0 U RECEIV JUL 19 20 PERMIT 1110 014 MECHANICAL LEGEND EQUIPMENT MARK (SEE SCHEDULE) RTU EQUIPMENT NUMBER AIR DEVICE No. OF AIR DEVICES ..0.- �-- MARK (SEE SCHEDULE) �- CFM 2 H 350 . ......, - -6. 1 IULriiii I i i___ 1 ®® , ®IL_Hamm _�,I ��O_'__Mr_.N_ CODE CODE COM II'I _ 560 0 T �i■1 ` �1� ,i, . �� t a o 0 o r o •• o o pt �LL %11f�IIII 1Ii, .. o ■�i11 City of Ti BUILDING BUILDING [ 1111 ■ ■ ■._ - : t� II/ 4111.■ .� Mai o • •�3IO� i t ! RIP •••• �Iao .I o a 0 24x1 1111 16"0 .,� _..� #' _ . Bill a .24x14 7� �cil :_ CI oCI a `,a^ ilo 0 i ^'��l►�I w �. i r•7 r '- ■ ari- - i � .W��� J1�, 1��11 ■_f iusi�MB ra! MBE 1 ® I � "�i FPB - � '��!! ■It■ :�:�: i�l� - =���__ IM �� ��� ��`=��illl II 4 �ME N 1 CONNECT SUPPLY DUCT TO NEAREST OF ADEQUATE SIZE. (TYPICAL) O PROVIDE CODE REQUIRED CLEARANCE DISCONNECT /CONTROL SECTION AND f DUCT. (TYPICAL) �I 1� ■!I ■I 18 "O '■ II�'OC�1`'il� i ,,I �y:�`� I II► �' ��; ►:.I'I ' ll+ I I'111 'II 7 OO DI nAnNE rat ■ � pp o 0 MI R® Co IER A KM 1.111 Illki .1 i NOTE: THIS IS A SAMPLE DETAIL. CONTRACTOR TO MODIFY THE HVAC LAYOUT FOR THE SPECIFIC PROJECT 0 0 0 0, 0 o, 0 0 SEPHORA MECHANICAL DETAIL SCALE: 1/8" = 1' -0" D FO1R PLIANCE VED 2010 kw.ila: IVIS IN DUCTWORK BETWEEN ETURN SEPHORA MECHANICAL NOTES HEATING, VENTILATING & AIR CONDITIONING SEPHORA AREA 1. THE GENERAL AND THE MECHANICAL CONTRACTOR SHALL ERIFY THE DUCT SYSTEM THAT WILL BE UTILIZED TO SERVE THE SEPHORA AREA, AND REPORT TO JCPENNEY WHAT TYPE OF SYSTEM IT IS DUCTED FROM ALONG WITH WHETHER THE UNIT THAT WILL SERVE THE SEPHORA AREA IS A CONSTANT VOLUME, VARIABLE AIR VOLUME, OR A UNIT RETROFITTED WITH A VARIABLE FREQUENCY DRIVE AND REPORT FINDINGS TO THE JCPENNEY PROJECT MANAGER. THESE FINDING WILL DETERMINE THE TYPE AND SIZE OF FAN POWERED MIXING BOXES. 2. REFERENCE THE SEPHORA MECHANICAL LAYOUT AND DETAIL ON THIS SHEET FOR AN EXAMPLE OF ALL SEPHORA DUCTWORK, DIFFUSERS AND CONTROLS. CONTRACTOR SHALL MODIFY THE HVAC LAYOUT FOR THE SPECIFIC PROJECT. 3. THE CONTRACTOR SHALL REMOVE THE EXISTING SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLES CURRENTLY INSTALLED WITHIN THE SEPHORA AREA AND PROPERLY SEAL AND CAP THE EXISTING DUCTWORK. IF REQUIRED, RELOCATE THE EXISTING SUPPLY AIR DIFFUSERS TO PROVIDE THE PROPER AIR FLOW TO THOSE PORTIONS OF THE SALES FLOOR ADJACENT TO THE SEPHORA AREA. 4. FAN POWERED BOXES (FPB) • THE CONTRACTOR SHALL FURNISH AND INSTALL TWO CONSTANT VOLUME (SERIES) FAN POWERED MIXING BOXES TO PROVIDE CONDITIONED AIR TO THE SEPHORA AREA. THE FAN POWERED BOXES SHALL BE SELECTED BASED ON THE TYPE OF AIR DISTRIBUTION SYSTEM IN THE STORE AND THE FPB SCHEDULES. • THERE IS A 7 WEEK LEAD TIME ON THESE BOXES. ORDERS SHOULD BE PLACED AS SOON AS THE PROJECT IS AWARDED TO AVOID QUICK -SHIP CHARGES. • 'THE CONTRACTOR SHALL PURCHASE THE FAN POWERED MIXING BOXES FROM TRANE, ALONG WITH HIRING THE SERVICES OF THE TRANE COMPANY TO CONTROL THE FAN POWERED MIXING BOXES THROUGH THE EXISTING ENERGY MANAGEMENT SYSTEM. CONTACT MATT LASSEN 972 -406 -3643 TO PURCHASE THE EQUIPMENT AND ARRANGE THE CONTROL WORK. COPY JCPENNEY'S BRENDAN SWEENEY, BJSWEENE @JCPENNEY.COM ON ALL CONTROL WORK REQUESTS. 5. DUCTWORK • PRIMARY SUPPLY AIR TO THE FAN POWERED MIXING BOXES SHALL BE DUCTED VIA SHEETMETAL DUCTWORK FROM THE NEAREST SUFFICIENTLY SIZED DUCT MAINS SERVING THE MAIN SALES FLOOR THAT CAN BE UTILIZE WITHOUT ADVERSELY AFFECTING THE QUANTITY OF AIR DOWNSTREAM OF THE NEW DUCT TAKEOFFS. • THE CONTRACTOR SHALL PROVIDE THE JCPENNEY PROJECT MANAGER AND THE TEST AND BALANCE CONTRACTOR WITH MECHANICAL DRAWINGS INDICATING THE LOCATION OF THE FAN POWERED BOXES, SUPPLY AIR REGISTERS, RETURN AIR GRILLES, DUCT LAYOUT, NEW DUCTWORK SIZING ALONG WITH THE SIZING OF EXISTING DUCT MAINS INCLUDING THE LOCATION OF THE TIE IN POINTS OF THE NEW DUCTS SERVING THE FAN POWERED MIXING BOXES. • SECONDARY AIR TO THE FAN POWERED MIXING BOXES SHALL BE SUPPLIED THROUGH 24° X 24" WHITE 35' FIXED BLADE GRILLES (TITUS 350 RL) LOCATED IN THE MAIN SALES AREA CEILING 20' - 0" FROM THE SEPHORA AREA AND DUCTED TO THE FAN POWERED MIXING BOXES VIA SHEETMETAL DUCTWORK. • THE CONTRACTOR SHALL FURNISH AND INSTALL SIX NEW 16" x 16" TITUS 300 RS DOUBLE DEFLECTION SUPPLY AIR REGISTERS WITH 24" X 24" TYPE 3 LAY IN PANELS SET AT 22 -1/2 ' DEFLECTION IN ALL 4 DIRECTIONS. PROVIDE AN INSULATED SHEETMETAL PLENUM BOX ABOVE EACH REGISTER. THREE REGISTERS SHALL BE CONNECTED DOWNSTREAM OF EACH FAN POWERED MIXING BOX. SEE TYPICAL LAYOUT FOR LOCATIONS. • FURNISH AND INSTALL SIX NEW 24" X 24" WHITE 35" FIXED BLADE RETURN AIR GRILLES WITH 1" WIDE FRAME (TITUS 350 RL). SEE TYPICAL LAYOUT FOR LOCATIONS. • COORDINATE THE LAYOUT OF THE NEW SUPPLY AIR REGISTERS AND RETURN AIR GRILLES WITH THE LIGHTING, SPRINKLER HEADS AND OTHER CEILING MOUNTED DEVICES. ADJUST THE LOCATION OF THE REGISTERS AND GRILLES AS REQUIRED TO AVOID CONFLICTS. • NEW DUCTWORK SHALL BE OF SHEET METAL CONSTRUCTION SIZED FOR A MAXIMUM .12" OF FRICTION. A MAXIMUM OF 8' -0" OF FLEXIBLE DUCTWORK IS PERMITTED BETWEEN THE SHEETMETAL DUCTWORK AND THE PLENUM BOX LOCATED ABOVE THE SUPPLY AIR REGISTERS. ALL DUCTWORK IS TO BE CONSTRUCTED AND INSTALLED PER SMACNA STANDARDS. • THE CONTRACTOR SHALL FURNISH AND INSTALL BALANCING DAMPERS IN ALL BRANCH DUCT TAKEOFFS TO THE REGISTERS SERVING THE SEPHORA AREA. BALANCING DAMPERS SHALL NOT BE INSTALLED IN THE TAP TO THE FAN POWERED BOX. • THE CONTRACTOR SHALL FURNISH AND INSTALL DOUBLE THICKNESS TURNING VANES IN ALL 90' DUCT ELBOWS. • ALL NEW DUCTWORK IS TO BE PROVIDED WITH EXTERIOR DUCT WRAP, IF THE EXISTING DUCTWORK SERVING THAT FLOOR IS INSULATED. 6. TEST AND BALANCE (TAB) • THE GENERAL CONTRACTOR SHALL HIRE THE SERVICES OF A JCPENNEY APPROVED TAB / COMMISSIONING AGENT TO BALANCE AND COMMISSION THE NEW FAN POWERED MIXING BOXES AND REGISTERS SERVING THE SEPHORA AREA. COMMISSIONING AGENT CONTACT INFORMATION IS AS SCHEDULED. • THE GENERAL CONTRACTOR SHALL PROVIDE MECHANICAL DRAWINGS TO THE TEST AND BALANCE AGENT PRIOR TO THEIR ARRIVAL AT THE SITE. • THE TAB MUST BE COMPLETED 4 WEEKS PRIOR TO THE OPENING DATE. ALL PUNCHLIST ITEMS MUST BE COMPLETED PRIOR TO THE OPENING DATE. • ALL TAB REPORTS SHALL BE SENT FROM THE TAB TO THE CONTRACTOR AND TO JCPENNEY PROJECT MANAGER, RICHARD MARNIK AT 6501 LEGACY DR., MAIL STOP 2111, PLANO TX 75024. REPORTS MUST BE DELIVERED WITHIN THREE WEEKS AFTER OF THE COMPLETION OF TAB PHASE. 7. ALL FAN POWERED BOXES OR OTHER MECHANICAL EQUIPMENT INSTALLED UNDER THIS SCOPE OF WORK SHALL BE PROVIDED WITH ELECTRICAL POWER THROUGH A NEW DEDICATED UNCONTROLLED POWER CIRCUITS. THIS ALSO INCLUDES 120V POWER TO ANY NEW ENERGY MANAGEMENT SYSTEM DEVICES REQUIRED TO COMPLETE THIS SCOPE OF WORK. NO NEW MECHANICAL EQUIPMENT SHALL BE SERVED OFF EXISTING CIRCUITS ALSO SERVING LIGHTING. 8. ALL NEW EQUIPMENT AND DUCTWORK SHALL BE SUPPORTED FROM STRUCTURAL BUILDING STEEL. SUPPORTING FROM THE DECK ABOVE OR FROM OTHER TRADES IS NOT PERMITTED. STOCK SPACE 1. THE CONTRACTOR SHALL FURNISH AND INSTALL A NEW DUCT AND SUPPLY AIR REGISTER WITH OPPOSED BLADE DAMPER (TITUS 300 RS) IF ONE IS NOT PRESENT WITHIN THE CONFINES OF THE SEPHORA STOCK SPACE SO AS TO MAINTAIN A MAXIMUM SPACE TEMPERATURE OF 78'. 2. IF THE STOCK SPACE IS FULLY ENCLOSED WITH SHEETROCK, THE CONTRACTOR MUST PROVIDE FOR ADEQUATE RETURN AIR OUT OF THE SPACE. 3. THE CONTRACTOR SHALL ADJUST THE SETPOINT OF EXISTING UNIT HEATERS OR OTHER TYPE OF EXISTING HEATING DEVICES LOCATED IN THE VICINITY OF THE SEPHORA STOCK SPACE TO 45'. FIRE PROTECTION 1. THE EXISTING SPRINKLER HEAD LAYOUT SHALL BE MODIFIED AS REQUIRED SO TO PROVIDE PROPER COVERAGE / CLEARANCE REQUIREMENTS BASED ON THE LAYOUT. OF THE SEPHORA SALES AND PERIMETER FIXTURING. (Rev. 5/18/10) REVISIONS A 12/03/2009 - DM ISSUED FOR SE REVIEW AND BIDDING 05/19/2010 - DM RELEASED AS DB w 0 U RECEIV JUL 19 20 PERMIT 1110 014 MECHANICAL LEGEND EQUIPMENT MARK (SEE SCHEDULE) RTU EQUIPMENT NUMBER AIR DEVICE No. OF AIR DEVICES ..0.- �-- MARK (SEE SCHEDULE) �- CFM 2 H 350 3 TER True North: Store Type: 1A Store No: 0696 Project Type: FLOOR PLANS Floor Level: MIDDLE Scale: AS NOTED Typ Ceiling Ht: 13' -0" Drawn By: D.MINER Date: 05/19/2010 Sheet No: 6 F6 1