Loading...
HomeMy WebLinkAboutPermit M10-096 - 12618 BUILDING - VACANT SPACEVACANT SPACE 12618 INTERURBAN AV S M10 -096 City otkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 0004800003 Address: 12618 INTERURBAN AV S TUKW Project Name: VACANT SPACE Permit Number: M10 -096 Issue Date: 08/10/2010 Permit Expires On: 02/06/2011 Owner: Name: GATEWAY OLYMPIA INC Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: LINDA NELSON Address: 11812 NORTH CREEK PY N - SUITE 104 , BOTHELL WA 98011 Email: LINDAN @PACIFICAIRCONTROL.COM Contractor: Name: PACIFIC AIR CONTROL INC Address: 11812 N CREEK PKWY N 104 , BOTHELL WA 98011 Contractor License No: PACIFAC230P8 Phone: 206 - 682 -6393 Phone: Expiration Date: 10/01/2011 DESCRIPTION OF WORK: REPLACE EXISITING 2.5 TON ROOFTOP GAS PACK (GP -1) WITH LIKE Value of Mechanical: $11,677.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $330.56 International Mechanical Code Edition: 2009 Date: 0 V L1/DC1,O I hereby certify that I have read and = ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work wil ; - complied whether specified herein or not. The granting construction Signatur Print Name: mit oe orm.: n o presume to give authority to violate or cancel the provisions of any other state or local laws regulating work. I uthorized to sign and obtain this mechanical permit. �iLFi 9�YLf� Date: 64/0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -096 Printed: 08 -10 -2010 • r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us Parcel No.: 0004800003 Address: 12618 INTERURBAN AV S TUKW Suite No: Tenant: VACANT SPACE PERMIT CONDITIONS Permit Number: M10 -096 Status: ISSUED Applied Date: 07/20/2010 Issue Date: 08/10/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10 -096 Printed: 08 -10 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of t •• permit does n t resume to give authority to violate or cancel the provision of any other work or local laws regulating construction or pe `��• rrr ce �f/Wi /Work. Signature: Print Name: �l Ufa) 1rz - G=l2 t Date: doc: Cond -10/06 M10-096 Printed: 08 -10 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Permit No. lit L 0— Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 000480 -0003 Site Address: 12618 INTERURBAN AVE S Tenant Name: Property Owners Name: Suite Number: GATEWAY OLYMPIA INC C/O CB RICHARD ELLIS New Tenant: Mailing Address: 12720 GATEWAY DRIVE #200 TUKWILA City Floor: ❑ Yes m..No WA 98168 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Linda Nelson Mailing Address: 11812 North Creek Pkwy N Suite 104 E -Mail Address: lindan @pacificaircontrol.com Day Telephone: 206- 682 -6393 Bothell WA 98011 City State Fax Number: 206- 340 -2270 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Pacific Air Control Mailing Address: 11812 North Creek Pkwy N Suite 104 Contact Person: Linda Nelson E -Mail Address: lindan @pacificaircontrol.com Contractor Registration Number: PACIFAC230P8 Bothell WA 98011 City State Day Telephone: 206- 682 -6393 Fax Number: 206- 340 -2270 Expiration Date: 10/01/2010 Zip ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: BTL Engineering Mailing Address: 17924 140th Ave NE Suite 220 Contact Person: Eric Dann Woodinville WA 98072 E -Mail Address: eric.dann @btleng.net 11:\ Applications \Forms-Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Applicatinn.doc Revised: 7 -2010 bh City State Day Telephone: 425 - 814 -8448 Fax Number: 425 - 821 -2120 Zip Page 1 of 2 • • Valuation of project (contractor's bid price): $ 11,677 Scope of work (please provide detailed information): Replace existing 2.5 -ton rooftop gas pack (GP -1) with like. Use: Residential: New Commercial: New Fuel Type: Electric ❑ Gas Replacement Replacement Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu 1 air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3-15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood /gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp/1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm incinerator — comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI 1 R OR AUT AG Signature: — Date: Print Name: Day Telephone: 7 )/ /o Mailing Address: L L (. FEi i— /741-3Y /0, irlee/L iA141- `1 City Slate Zip Date Application Accepted: _)_40, 1 0 Date Application Expires: Staff Initials: (lj fl H:1ApplictioneTut na -Appl iwtions CA. 1.4n 2C IC Applications`.? -2010 - bta:hani,l Pei mu Applkatiun.do: Revised: 7 -2010 bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0004800003 Permit Number: M10 -096 Address: 12618 INTERURBAN AV S TUKW Status: APPROVED Suite No: Applied Date: 07/20/2010 Applicant: VACANT SPACE Issue Date: Receipt No.: R10 -01538 Initials: User ID: JEM 1165 Payment Amount: $264.45 Payment Date: 08/10/2010 09:35 AM Balance: $0.00 Payee: PACIFIC AIR CONTROL, INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 14714 264.45 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 264.45 Total: $264.45 PAY. ENT RECEIVED doc: Receiot -06 Printed: 08 -10 -2010 i • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 0004800003 Permit Number: M10 -096 Address: 12618 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 07/20/2010 Applicant: VACANT SPACE Issue Date: Receipt No.: R10 -01358 Initials: User ID: Payee: WER 1655 Payment Amount: $66.11 Payment Date: 07/20/2010 02:12 PM Balance: $264.45 PACIFIC AIR CONTROL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 14630 66.11 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 66.11 Total: $66.11 PAYMET RECEIVED doc: Receiot -06 Printed: 07 -20 -2010 • INSPECTION RECORD Retain .a copy with permit INSPECTION NO. PFSRMIT NO CITY OF TUKWILA BUILDING DIVISION -�- 6300 Southcenter Blvd., #100; Tukwila. WA 98188 (206) 431 --3670 Permit Inspection Request Line (206) 431 =2451 Project: �' Type of Inspection: c:A: t Al ejl, Addl�ss: Date Cared: Sp cia Instructions: Date Wanted: ( a m Requester: Phone No: 2 l Approved per applicable codes. Corrections required prior to approval. COMMENTS: c r • Eck,- I Ate-4. .fr"*""4 r j u, 1)(ie Inspector: Date:9 n REINSPECTION FEE REQUIRED: Prior to next inspection, fee.must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection; r e•cr���n.•v �s �z _ �yaram .� • •• .. ... �_ticaa , ••: ar- rsv+�e INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 So44hce.nter Blvd., #100, Tukwila. WA 98188 v(206) 431 -367 Permit Ibspec 'On Request tine (206) 431 -2451 �- M , WI Project: j 4-( Cam. Type of Inspection: frk..L& �-n G- Addfess: . J . 7.4 i 0 // - r0'dd'4'1 Date Called: Special Instructions: ,. � Date Wanted: x a.m. Requester: - - Phone No: - 7 G - 4 23 ?A ❑ Approved per applicable codes. • (ti orrections required prior to approval. . COMMENTS: t • ..a iy f d j ff 4 !JIC- l ~; Yom' e .° . f . . ....ate x 0. r2% ). . . - • f• 4st i --- - ' - • . . o 4... _ s 1• * - A 1 ;! 1 • 4. • nspj3ctor: I•c Date: "r- REINSPECTION FEE REQUIRED. Pri. r to next inspection. fee must be paid at 6300 Southcenter.Blvd., Suite 900: Call to schedule reinspection. agr*•r - .. +r w: • .. ! vs.• f•.f Tr — -- .. —:-t 2006 Washington State Nonresidential Energy Code Compliance Form eclanicalSumma 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Tukwila Commerce Park GP -1 replacement Date 7/20/2010 Capacity2 Btu /h 12816 Interurban Ave S, Tukwila 98168 For Building Dept. Use FILE COP SEER or EER IPLV3 Applicant Name: Pacific Air Control Applicant Address: 11812 North Creek Pkwy N, Bothell 98011 Applicant Phone: 206 -682 -6393 Project Description Briefly describe mechanical system type and features. Includes Plans Replace 2.5 -ton gas pack (GP -1) with same Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option 0 Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location GP -1 TRANE 4YCC3030 30000 1000 ECONO 13.00 59600 ROOF Heating Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' GP -1 TRANE 4YCC3030 30000 1000 ECONO 75000 59600 79.500 Fan Equipment Schedule Equip. ID Brand Name' Model No.1 CFM HP /BHP Flow Controls Location of Service NUb 0 5 f avail loiF� ; p..�i ording to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF Combustion Efficiency, or AFUE, as pplicabl cdn't . �'� : variable air volume(VAV), constant volume (CV), or variable speed (VS). BUILDING of 'RIi1N 110 2006 Washington State Nonresidential Energy Code Compliance Form llec ianiea um'ma System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: • Constant vol? Air cooled? X Packaged sys? Economizer included? <20,000 Btuh? ❑ Split system? If Heating Only: <5000 cfm? <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. CSTART J System Type Heating Only T <5000 cfm? Heating /Cooling . r Cool. Reference Section 1421 Yes ,, No /' /70% OSArYes* KAir Cooled, Constant Vol? /Single■ Package Unit ?. No Split Systern -- No <= 84,000 Btuh? % Yes T / /"tee / AHU Outdoors Cool Cap. Included?, : >—No I.,' `20,000 '> —No►, Adjacent to Btuh ?; :: puuttd0000r- 1 No Cool Cap. Yes <54,000 NBtu Reference Section 1423 Simple System Allowed (section 1420) Yes ,Total C pN wo economizerN N <240,000 Btuh Nor 10% Yes ..1 No Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form i; y,: r. t1R0 _ +r ,?i,,� ' `+5 .t Mechanic`al'�" Complex :Systemsl,Checklist ' .. . a. 1 �.` ..b s N . 2006 Washington State Nonresidential Energy Code Compliance Forms $r a<S t - -r .Irir ;7r �,'�' MECHr*COMP r . ,..rt.... .... r . 1 .... .....1 .. r ... 1 ... �fV# ,r...h..� t 6., r';r1t. _ 1 n.... .. .. - .. Revised July 2007 Project Address Tukwila Commerce Park GP -1 replacement Date 7/20/2010 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY N/ 1431.1 Field assem. sys. Provide calculations 111 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized 1434 Separate air sys. Indicate separate systems on plans 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air 1439.2 Fume Hoods Indicate VAV, unheated /uncooled or heat rec. makeup no is circled for any question, provide explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Start Here • Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14-1G Gas /Oi Fumace._ ►` input ? 225,000 8tuh or Gas /Oii Unit Healer-) • r Yes 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input? 225,000 Biuh then 1412.6 Modulating or Staged Combustion Controls Required • Any Fuel Furnace. Field- Assembled Input _ 225.000 Equipment-) Btuh Yes T 1411.1 0.75% Maximum Jacket Loss Yes Section 1431.1 Calculations of Total On -Site Energy Input 8 Ouput Required Air System Serving Multiple - Zones-) Yes Section 1432.2.1 Supply Air Reset Controls Required (continued on back) N Capacity of HW. H :- Heating System >`�- 300.000 Bluh-) Yes Section 1432.2.2 Hot Water Supply Temperature Reset Required 1 No 2006 Washington State Nonresidential Energy Code Compliance Form Ieclanical FaC;om`plez= Systemts`;(bac P• 2006 Washington State Nonresidential Energy Code Compliance Forms 0% Air Econo, l Provided? Section 1413 Yes �\ No Water Cooled ww \r Econov .�� Yes EER 10% Better ,_No_ than Code i Yes • Yes 1. tal Cap. cono <= 480,00 N, Btuh or 20% of \Total Ca Yes NoJ Section 1433 Economizer Required pply Air >5 0O0 Section 1436 cfm & OSA > — Yes_►, 50% Effective Heat 70% Recovery Required ZNN otor Inc! . l / Multi-speed \ Egpmt Covr'd by' 2—No ► ; Motor in Multi \Tbl 11GA -1� \speed system? Yes Yes Yes Section 1437 Motors Must Meet Efficiencies in Table 14 -4 Section 1435 stern or Zones, Zone Controls Must w/ Simultaneous Yes-► Reduce Supply Air Htg. & Clg. ?r Quantity Before Reheating /Recooling No Appllcatton ' - Yes Section 1438 f Involves Variable >— Yes -K /Fans or Pumps > Yes-► Variable Flow Flow? \ 10 HP? . Devices Required No tal Bldg. Fu Exhaust > 15,000 cfm? No itchen Exhaust. Hood > 5,000 Yes-* �\ cfm 0 T Yes No DONE Yes • Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Yes Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Form h :4W % A' ..; �iv� t`, .. r , :. ,1l .' %li i F . ` �,. ! ' �s J 4 f - rt ' Y ..,,Y' Mechanical Permit Plans Checklist �t ��R{ 1° y�?% ` fi T i'tt MEC." .�.x;t. .. ., a:....4 .`s ....r ....,xr ,�..t ".,• -,.,. _µ v. .,p ..,.,.r .. a. ft F:. .,,?:,. - ...;,. , �' C �. eCfx '!"F� �'4. - ^..t !'i .ikP'l:rwt..i, x..t _ ,.. ^� a 2006 Washington State Nonresidential Energy Code Compliance Forms Revised <, •..r, {.�. i -,. t . July 2007 Project Address Tukwila Commerce Park GP -1 replacement Date 7/20/2010 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule M -1 yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M -1 yes 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss M -1 1412 HVAC controls n.a. 1412.1 Temperature zones Indicate locations on plans n.a. 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control n.a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule M -1 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M -1 n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling M -1 n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems n.a. 1414.1 Duct sealing Indicate sealing necessary n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements n.a. 1416.2.1 Commissioning Provide commissioning plan n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training M -1 yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M -1 n.a. 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover no is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Iec anica rm i 'ecu 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124-1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Blu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss 0110 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke defection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable on buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking arrsrde economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation 10 the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any extenor envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Blu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss 0110 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke defection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable on buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking arrsrde economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation 10 the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any extenor envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form • 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btulh shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) BTL FILE COPY ENGINEERING •. w• 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Structural Calculations for Tukwila Commerce Park Mechanical Unit GP -1 July 20th, 2010 REVIEWEP ANCE CODE COM A ;- }PROVED AUI05201I City of Tukwila BUILDING DIVISION RECEIVED JUL 2 0 2010 PERMIT CENTER BTL ENGINEEPJNG ill 17924 -140th Avenue NE, Suite 2z0 Woodinville, WA 98072 -4315 Phone (425) 814-8443 Fee (425) 821 -2120 Calculations BTL ENGINEERING a) 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Poe (425) 821,2120 Gravity Support 50' • COLUMN Be COLUM GIB 6- 3/4'X33" (MEASURED) OLD LOCATION GP -1 ON 4X4X8'SLEEP PURLJNS ® 8' O.C. 71'X8' KYUGHT 2X12 FRAMING AROUND SKYLIGHT 24' PROPOSED LOCATION 2X4 FRAMING OF I-1VAC UNIT APPROX. 500 LBS 24" O.C. (TYP.) TOTAL WEIGHT RIOR CONCRETE WALL Q) TUwMMERCE PARK TUKWILA COMMERCE PARK GP -1 REPLACEMENT SCALE: 1/8"=1'O" 7/2/10 BTL ENGINEERING 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone 425-814-8448 Fax 425-821-2120 04 eCt Pv4 Co../ Al i I b 1.. ) ar AI k " , it 7 2° 1 1'1 V •-• 3 .4. lo ir-FT-71" 5 o t ( t A Afi 2 $. 2 5 t 40 (.(1.13,$)65,,,tqc, 2 , /5� Pr r ie. = l5 p.. o IC_ . 36 1 (.l._ 6K (*1 (JIPe(14,,, i Project: Designed By Date: Page. Project Number: Client Scale. BTL ENGINEERING 17924 —140th Avenue NE, Suite 220 Woodinviile, WA 98072-4315 Phone: (425) 814.8448 As (425) 821 -2120 Seismic Support Tukwila Commerce Center 10 -341 -05 Revision Date: 7/6/2010 Occupancy Category: II - Other Structures v Seismic Use Group: I IE = 1.00 Is = 1.00 /, = 1.00 Site Class: Ss = 1.5 Si = 0.5 (Seismic Factor) (Snow Factor) (Wind Factor) D v Fe = 1.00 F„ = 1.50 ASCE Table 11.4 -1 ASCE Table 11.4 -2 Design Spectral Response Acceleration: Sus =F8Ss = 1.50 SDs =%SMS = 1.00 IBC Table 1604.5 ASCE Table 20.3 -1 SM1 = F„S1 = 0.75 SD1 =%SM1 = 0.50 5 Tukwila Commerce Center Revision Date: 7/6/2010 10- 341 -05 Seismic Forces Component Operating Weight: 500 Ibs Fp = Fp = F p need not exceed: F = 0.4 ap SDS Wp Rp/ lo 240 lbs 1.6Sps 1pWp F = 800 Ibs F p shall not be less than: F = F = Dimensions: x= Z= Curb Height = Check Uplift: MOT = MRESrsr = 0.3Sps IWp 150 lbs 43 in 48.5 In 35.5 in 14 in 7620 lb-In 9675 lb-in [1 +2 (zlh)] z Curb Height x ASCE Eq. 13.3 -1 ASCE Eq. 13.3 -2 ASCE Eq. 13.3 -3 Y I LI F.S. = 1.3 NOT O.K. 1.5 clt 0■,JEt) v.'t C otitis Crl Ot ) TAG: YCC3030A -SUB -1 E SUBMITTAL SINGLE PACKAGED GAS HEATING ELECTRIC COOLING PRODUCT SPECIFICATIONS 2YCC3030A 1040/64175A MODEL 2YCC3030A1040A RATED Volts/PH/Hz 208- 230/1/60 Performance Cooling BTUH(I) 28000 Indoor Airflow (CFM) 1025 Power Input (KW) 2.6 EER/SEER (BTU/Watt-Hr.) 11.0 / 13.0 Sound Power patina fd6(A110 74 Performance Heating® Input BTUH (Natural Gas)C 40000 AFUE 80.0 Temp. Rise - Min/Max ( °F) 25 / 55 Orifice O / Drill Size (Natural Gas) 1 / #32 POWER CONN.- V /PH/HZ 208 - 230/1/60 Min. Brch. Cir. Ampaclty 15.7 Fuse Size - Max. (amps) Fuse Sire - Recmd. /most COMPRESSOR Volts/Ph/Hz L Ames - L R Amps OUTDOOR COIL - TYPE Rows/F.P.I. Face Area (sq.fl) Tube Size (in.) INDOOR COIL - TYPE Rows /F.P.I. Face Area (sq.%) Tube Size (in.) Refrigerant Control Drain Conn. Size (In_) OUTDOOR FAN - TYPE Dia. (in.) Drive/No. Speeds Motor - HP /R.P.M. Volts/Ph/Hz F.L. Amps /L.R. Amos INDOOR FAN - TYPE Dia x Width (in.) Drive /No. Speeds CFM ® 0.0 in. w.g.• Motor - HP /R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN TYPE Drive /No. Speeds Motor - HP /R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (so. %IS REFRIGERANT charae (Ibs.14) GAS PIPE SIZE (in.) DIMENSIONS Crated (In.) WEIGH Shipping (Ibs.) / Net (Ibs.) 470 / 374 2YCC3030A1064A 208 - 230/1/60 28000 1025 2.6 11.0 / 13.0 74 2YCC3030A1075A 208-230/1/60 28000 1025 2.6 11.0 / 13.0 74 25 25 RECIPROCATING 208 - 230/1/60 104 /652 SPINE -FIN 2/24 13.32 3/8 PLATE FIN 3/15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 1/12 / 810 208-230/1/60 0.54 / 0.95 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1030 200 - 230/1/60 2.1 / 3.28 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.53 NO THROWAWAY 4 R22 5.5 1/2 HXWXL 45.86 / 44.5 / 52.03 64000 80.0 30 / 60 2 / #37 208-230/1/60 15.7 25 25 RECIPROCATING 208 - 230/1/60 104 /652 SPINE -FIN 2/24 13.32 3/8 PLATE FIN 3/15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 1/12 / 810 208 - 230/1/60 0.54 / 0.95 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1030 200 - 230/1/60 2.1 / 3.28 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208 - 230/1/60 0.53 NO THROWAWAY 4 R22 5.5 1/2 HXWXL 45.86 / 44.5 / 52.03 481 / 385 75000 79.4 35/65 2 / #33 208- 230/1/60 15.7 25 25 RECIPROCATING 208-230/1/60 104 / 652 SPINE -FIN 2/24 13.32 3/8 PLATE FIN 3/15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 1/12 / 810 208 - 230/1/60 0.54 / 0.95 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1030 200-230/1/60 2.1 / 3.28 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208 - 230/1/60 0.53 NO THROWAWAY 4 R22 5.5 1/2 HXWXL 45.86_/ 44:5- 142:Q3 481 / 385 ()Rated In accordance with A.R.I. Standard 210/ 240. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. ®AII models are certified toUL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 R elevation. °Convertible to LPG. °Thtsvalueisapproximate. For more precise value, see Unit Nameplate. ° Based on U.S. GovemmentStandardTests. ° Fitters mustbe Installed In return airstream. Square footages fisted are based an 300 f.p.rn. face velocity. If permanent filter; are used size per rrrenulacturers recommenda- tion with a clean resistance of 0.05- W.C. © Sound Power values are not adjusted for ARI 270-95 tonal corrections. SAS Soo 16 5 -3 © 2009 Trane NOTICE: The manufacturer has a policy d continuous product and produce data improvement and reserves the right to change design and specfRcadons wtthout notice. Unit Clearance and Weight Information 25.10 (11 1 11.56 (15/321 (DUCT FLAM6E) 1. A 18.03 (23/32) 175.23 (18-23/321 ONDENSATE DRAIN FOR 18.0 (3111 FEMALE NPT 18.29 (23/32) 14.22 (9/167 SECTION Y -Y TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS 2 INLET ��IINp IO ��� a 1 OUTLET 200.21 17.7/81 $ ENTER OF GRAVITY BOTTOM SIDE S -4 teTr.■•`!:.;:-.41111110.7.:.if,a,4)71 %_-L - -- ;,,,ice , 19.50 [3 -1 /8] 398.22 -'11 [15-11 /161 (OUTSIDE e% SUPPLY r 530.60 120 -7/81 1153.46 11S -1/21 (SURFACE AREA) BACK SIDE 296.62 (11- 11/16] (OUTSIDE/ 58.19 [2 -9/321 i- 17].55 116.01 (6- 15116] 398.22 [15- 11/161 (OUTSIDE) OACK DUCT OPENINGS 17.78 [11 /161 TYPICAL (8) SIDES O� DUCT OPENINGS MODEL 0E1461 101 /1N. FLUE MOOD W /BR. APPROX. CORNER WEIGHT - KG/LOS SHIPPING WEIGHT N6 /180 TOTAL UNIT WEIGHT NG /L6S CEIITER OF GRAVITY 101/111. A 0 WI W2 W3 W4 B C 41CC3018 (040) 898.53 135-3/81 - 58.1 11281 36.7 181] 29.5 1651 46.3 1)021 213.8 1411) 170.1 13751 401.3 115.8] 546.1 [21.51 21ICC3024 10401 51.6 11211 36.3 180] 29.0 164] 46.3 11021 213.4 (110) 169.6 13741 401.3 (15.81 546.1 121.51 21CC302/ 10641 58.5 11291 36.7 [811 30.8 1881 48.5 [1071 218.4 14811 174.6 (3851 401.3 [15.81 558.8 122.01 411CC3024 (064) 59.0 11301 37.2 [821 31.3 1891 48.5 (691 218.4 (481) 111.8 (385) 401.3 (15.0] 546.1 [21.51 2YCC3030 (040) 56.1 11251 35.8 (791 29.9 166) 41.2 1104] 213.4 (410) 169.6 1374] 401.3 [15.81 558.8 [22.01 2YCC3030 1064/0751 157.16 16.3/161 58.1 11281 36.1 (811 30.8 1681 48.5 (1071 218.4 1481) 174.6 [3851 401.3 115.8) 558.8 (22.01 41CC3030 10751 157.16 (6-3 /161 59.0 11301 37.2 (821 31.3 1691 48.5 [69] 218.4 (481) 114.8 13851 401.3 [15.81 546.1 121.51 2YCC3036 (064/0151 151.16 (6-3/161 59.0 [1301 35.4 1781 29.5 1651 49.4 11091 217.5 (419) 173.7 13831 388.6 115.31 558.8 122.01 2YCC3036 (096) 59.9 (132) 36.3 [80] 29.9 1661 50.3 [1111 220.2 (485) 176.4 [389] 388.6 [15.3) 558.8 122.0] 41CC3036 (064/0751 60.3 11331 36.3 (80) 30.4 1611 50.3 11111 221.6 (488) 177.8 13921 388 6 [15.31 558.8 [22.01 40CC3036 (096) 61.2 1135) 36.7 181] 30.8 (681 51.3 1113) 223.8 1493) 180.1 [3971 388.6 115.31 558 8 122.0] 5 r-s BTL ENGINEERING 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phonc 425 - 814 -8448 Fax: 425 -821 -2120 Cda (, t o r,1 or Cv2 6 goof F L/ . i FT 240 t bs -7G 2U — . ( (du,/ 5..) 05e 2) -i .4 3 foi EA S 'nC ( . 71)7 4 I) 115SUMC AN+2 4 U ro? fug Pi e- /R 2 U Foa (JR. r -7 d ArL1 5-1/ea4 /fv ew 2 4 o/ 12 0 17/R/ .cL) f s( 4 2" 7_ (1,7 We- 4t2 ger o� CJuur7 SGib Ftt rv\ U►.) 1 ?' "h�...... C u2 C Ar r,............Cc.ferS r-Th tdu f: Project: Project Number: Designed By: Date. Pte. S ^b Client: Scale. • ENGINEERING 17924— 1406 Avenue NE, &dte 220 Woodinville, WA 98072-4315 Phone (425) 814-8448 Fie: (425) 821,2120 Details a 0 • SE T PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -096 DATE: 07 -20 -10 PROJECT NAME: VACANT SPACE SITE ADDRESS: 12618 INTERURBAN AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building" Division Public Works LA N A— Ire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: t%1 Incomplete DUE DATE: 07 -22 -10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 111 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-19 -10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PACIFIC AIR CONTROL INC UBI No. 601298907 Phone 2066826393 Status Active Address 11812 N Creek Pkwy N License No. PACIFAC230P8 104 Suite /Apt. License Type Construction Contractor City Bothell Effective Date 10/28/1977 State WA Expiration 10/1/2011 Date Zip 98011 Suspend Date County King Specialty 1 Business Type Corporation Parent Company Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date CRAWFORD, LARRY C Cancel Date 01/01/1980 Bond Amount RUTTAN, GARY J 9 01/01/1980 104920215 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 TRAVELERS CAS & SURETY 104920215 05/26/2007 Until Cancelled $6,000.0005/09/2007 05/24/2010 8 MERCHANTS BONDING CO (MUTUAL) WA14019 05/26/2005 Until Cancelled 05/26/2007 $6,000.0005/25/2005 /02/2009 7 CUMBERLAND CAS & SURETY CO MB009001243 10/01/2001 Until Cancelled 05/26/2005 $6,000.00 09/20/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 19 PHOENIX INSURANCE COMPANY THE 4TC07314N491PHX09 07/01/2010 07/01/2011 $1,000,000.00 05/24/2010 18 PHOENIX INSURANCE COMPANY 4TC07314N491PHX09 07/01/2009 07/01/2010 $1,000,000.0007 /02/2009 17 NATIONWIDE MUTUAL INS CO ACP7501585754 07/01/2009 07/01/2010 $1,000,000.00 06/17/2009 16 NATIONWIDE MUTUAL INS CO ACP7501585754 07/01/2004 07/01/2009 $1,000,000.00 05/27/2008 15 SC BCS0006126 07/01/2003 07/01/2005 $1,000,000.0006 /10/2004 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By HOOPER ELECTRIC CO KING Date: 01/19/1984 https://fortress.wa.gov/lni/bbip/Print.aspx Date: Open Date: 08/10/2010 HVAC EQUIPMENT SCHEDULE MARK MAKE MODEL NOM TONS COOLING [MBH] HEATING [MBH] EVAP FAN ESP TOTAL CFM MIN _ OSA AMPS — MCA 208- 230v/1 ph WT [LBS] NOTES TOTAL SENS. SEER INPUT OUTPUT AFUE HP MOTOR TYPE [IN. WC] GP -1 A TRANE 4YCC3030 2.5 30.0 24.0 13 75.0 59.6 80 0.5 CENTRIFUGAL DD/ VAR 0.5 1000 ECON 19.2 385 ECONOMIZER HVAC GENERAL \OTES 1. VERIFY SITE CONDITIONS. 2. THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT /GC. DEFAULT MOUTING HEIGHT IS 60 AFF. CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES. COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH ARCHITECT APPROVAL. VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT 1999. EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY LINE OR OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS. 2006 IMC, SEC. 502.7.3.6, ITEM #3. TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING, INCLUDING WRITTEN REPORTS. 9. OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE INSTRUCTIONS, AND MARKED UP AS BUILT DRAWING. 10. WALK —THRU INSTRUCTION: PROVIDE ON SITE WALK —THRU FOR CUSTOMER TO DEMONSTRATE OPERATION OF SYSTEM AND ANSWER QUESTIONS. 11. ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF EQUIPMENT FOR SERVICE & MAINTENANCE PURPOSES (2006 IMC SEC. 306). LINE VOLTAGE WORK BY OTHERS. DUCT NOTES 1. DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE 2006 IMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT, EXCEPT AS NOTED. 2. BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF DIFFUSERS. DUCT INSULATION: MANVILLE FIBERGLASS DUCT WRAP, TYPE 75, FSK ALUMINUM FOIL FACING OR EQUAL. SUPPLY AND RETURN DUCTS: WITHIN CONDITIONED SPACE = R -3.3; OUTSIDE BLDG INSULATION ENVELOPE (ATTIC) = R -7; IN GROUND, IN CONCRETE = R -5.3; EXPOSED IN SAME COND. SPACE SERVED = NONE. OUTSIDE AIR DUCT IN CONDITIONED SPACE: R -7 WITH VAPOR BARRIER. EXHAUST DUCT INSIDE BUILD = NONE, IN ATTIC = R -4. 2006 WSEC, TABLE 14 -5 AND 2006 WSVIAQC. DUCT SEALING- GENERAL: 0 TO 2" STATIC PRESSURE — SEAL ALL TRANSVERSE JOINTS ON ALL DUCTS. ABOVE 2" -SEAL SEAMS & JOINTS. INSIDE BUILD: DURODYNE "DDS -181 "GRAY OR APPROVED EQUAL PER UL 181 A —M, 181B—M LISTED. OUTSIDE: POLYURETHANE, MAMECO VULKEM 116. OR APPROVED EQUAL. TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4 DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER SMACNA STANDARD. FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS NOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS & SCREWS ALLOWED. SOUND LINER: PROVIDE SOUND LINED METAL SUPPLY & RETURN DUCTS AS SHOWN ON PLANS. MANVILLE PERMACOTE LINACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH ACRYLIC SURFACE TREATMENT OR EQUAL. FABRICATE AND INSTALL PER DUCT LINER STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC. FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK —UPS TO ISOLATE AIR HANDLING EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE) DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR RECTANGULAR DUCTS THAT ARE NOT LINED. PROVIDE CIRCULAR EQUIVALENT OF RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE SUBSTITUTED TO BETTER FIT SPACE. 10. TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL OPENINGS. CONSTRUCTION \OTES SET MINIMUM OUTSIDE AIR DAMPERS OF ECONOMIZER PER EQUIPMENT SCHEDULE. LOW VOLTAGE CONTROL WIRING AND ALL OTHERS WIRING BY OTHERS. STRUCTURAL MODIFICATION BY OTHERS AS /IF REQUIRED. ROOFTING, CUTTING, PATCHING! & PAINTING BY OTHERS AS /IF REQUIRED. GAS PIPING TO RUN ON ROOF. SEI I ING AND INSTALLATION OF GAS METERS BY OTHERS. PER vI IT \OTES MINIMUM OUTSIDE AIR FOR VENTILATION OF OFFICE AREAS WILL BE ADJUSTABLE AND SET FOR 350 CFM BASED ON 25 PEOPLE PER 1000 SQ FOOT FOR THIS 540 SQUARE FOOT AND 25 CFM PER PERSON. FOR 14 PEOPLE X 25 CFM = 350 CFM. OPERATION AND MAINTENANCE MANUALS WILL BE PROVIDED AT COMPLETION OF PROJECT. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Get lectrical ?SD umbing r Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. LEGAL DESCRIPTION: LEGAL ADDRESS: 12600 INTERURBAN AVE S, TUKWILA SYMBOL ABBREV. q � s LEWIS C C —D C # 37 BEG N 81 -44 -15 E 199.17 FT FROM HUB AT END OF CURVE ON CENT LN OF DUWAMISH — RENTON JUNCTION RD SD HUB BEING APPROX 1200 FT N AND 440 FT W OF 1/4 COR BET SECS 14 & 15 -23 -4 TH N 49 -24 -00 W 2535 FT TH N 09 -36 -00 E 52 FT TO TRUE BEG TH S 82 -40 -30 E 590 FT TH N 59 -22 -30 E 643.35 FT TH N 01 -51 -30 W 343 FT TO LEFT BANK OF DUWAMISH RIVER BEING NLY BOUNDRY OF LEWIS D C TH SWLY ALG SD BANK OF RIVER TO PT N 00 -39 -40 W OF TRUE BEG TH S 00 -39 -40 E TO TRUE BEG ALSO POR OF D C LY W OF ABOVE DESCRIBED LAND SLY 16.15 FT AND A 16 FT STRIP ADJ AND PARL TO ELY LN OF R/W OF P S ELEC CO FOR JOINT RD TGW LOT 47 OF PLAT OF RIVERSIDE INTERURBAN TRS TAX PARCEL NUMBER: 000480 -0003 Taxpayer GATEWAY OLYMPIA INC. SITE PLAN 1:50 AIR QUALITY AND ENERGY CODE THESE PLANS COMPLY WITH THE 2006 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE AND THE 2006 WASHINGTON STATE ENERGY CODE. DESCRIPTION OF WORK: DEMO AND REPLACE EXISTING 2.5 —TON HVAC UNIT (GP -1) WITH LIKE UNIT WITH ECONOMIZER, ROOF CURB. LE Permit No. M 1Q- O(O Plan review approval is subject to errors and omissions. 5rovai of construction documents does not authorize : violation of an . a* opt code or ordinance. Receipt 7 7 z -�-- [ 2 -50 LEGEND & ABBREVIATIONS DESCRIPTION SYMBOL SUPPLY DUCT • RETURN /EXHAUST DUCT SL SOUNDLINED DUCT VD MANUAL VOLUME DAMPER FC FLEX CONNECTOR 1v TURNING VANES EC END CAP SD SUPPLY DIFFUSER, CEILING MG MAKEUP GRILLE RG RETURN GRILLE, CEILING EG EXHAUST GRILLE, CEILING TG TRANSFER GRILLE, CEILING SIDEWALL SUPPLY /MAKEUP SIDEWALL RETURN /EXHAUST EQUIPMENT TAG AFF ABOVE FINISHED FLOOR BD, BDD BACKDRAFT DAMPER BS BIRDSCREEN DN DOWN EA EXHAUST AIR OA, OSA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR (N) NEW (E) /EXIST EXISTING (R) RELOCATED BWG BOTTOM WALL GRILLE TWG TOP WALL GRILLE TYP TYPICAL VD VOLUME DAMPER DEMO POINT OF CONNECTION ABBREV. DESCRIPTION FIRE DAMPERED DUCT PENETRATION OF A HORIZONTAL SEPARATION FIRE DAMPERED DUCT PENETRATION OF A VERTICAL SEPARATION TIMER 0 -4 HR ADJUSTIBLE EXHAUST FAN PIPE /DUCT UP PIPE /DUCT DOWN PIPE TEE DOWN PIPE TEE UP EXIST DUCTWORK, EQUIP NEW DUCTWORK, EQUIP ADJ ADJACENT BSC BIOLOGICAL SAFETY CABINET CFH CHEMICAL FUME HOOD CFM CUBIC FEET PER MINUTE DB DUCT BOARD L,S LIQUID, SUCTION N NECK NIC NOT IN CONTRACT OAI OUTSIDE AIR INTAKE RD ROUND DIFFUSER SHC SENSIBLE HEATING CAPACITY SR SUPPLY REGISTER TC TOTAL COOLING VEL VELOCITY WH WATER HEATER CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN HTWS HOT WATER SUPPLY HTWR HOT WATER RETURN FC FAN COIL UNIT FD FUME HOOD approve * 'rid + 0 / I « n `ors is acknowledged• it IN B Date: City Of Tukwila BUILDING DIVISION ® ROUND DUCT UP C=I ROUND DUCT DOWN AIR TERMINAL LEGEND GRILLE, REGISTER, DIFFUSER IN LEGEND XX 8x8 --- NECK SIZE (INCHES) 140 SQUARE OR RECTANGULAR AIR QUANTITY (CFM) NECK SIZE (INCHES) XX 81'0 ---- 140 ROUND Air Quantity (CFM) ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS NO ARROWS INDICATE FOUR WAY PATTERN TAG CONTROLS ROOM SENSOR. DIRECT DIGITAL CONTROLS BY KMC OR OS EQUIVALENT. MOUNT SENSORS AT 48"-60" AFF. VERIFY LOCATION WITH GENERAL CONTRACTOR. PROGRAMMABLE THERMOSTAT. MOUNT 48 " -60" AFF. AIR QUALITY AND ENERGY CODE THESE PLANS COMPLY WITH THE 2006 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE AND THE 2006 WASHINGTON STATE ENERGY CODE. REVIEWED FOR CODE COMPLIANCE / u Auu 0 5 2010 RECEIVED [td- i y of Tukwila BUILDING DIA/IgIfN 14- JUL 20 2010 + PERMIT CENTER M -1 COVER SHEET, LEGEND, SITE PLAN M -2 ROOF PLAN, DETAILS 1Ioo �D Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 11812 Northcreek Parkway N., Suite 104 Bothell, WA 98011 ph: (206) 682 -6393 fax: (206) 340 -2270 Contractor's License No.: PACIFAC230P8 www.pacificaircontrol.com c� 1-1 co W Z> to W Z 00 W Q (,) L:( Q J 0 Ce W W J l-- r EL co SI r CO N r PROPOSED PROJECT FOR: DATE 7/20/10 DESCRIPTION PERMIT ISSUE A A A A THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL INC. ANY REPRODUCTION, DUPLICATION, ADDrrIONS AND /OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER EG DESIGNED BY DRAWN BY DL CHECKED BY EG SCALE AS NOTED PROJECT Na T100609 DRAWING 111LES COVER SHEET FlLEPATH: U : \ACAD \PROJECTS\ SHEET NUMBER M -1 of 2 COPYRIGHT © 2001 PACIFIC AIR COMM. INC UNION REDUCE AS REQUIRED GAS SHUTOFF VALVE GAS > PROVIDE TREATED SUPPORT BLOCKS ON ROOF PAD DRIP LEG ASSEMBLY CONDENSATE DRAIN TO NEAREST ROOF DRAIN & PVC P —TRAP GAS AND DRAIN CONNECTION DETAIL NTS FACTORY CURB INSULATION ANCHOR TO STRUCTURE BELOW EQUIPMENT SECURE UNIT TO CURB PER STRUCTURAL BUILT UP ROOFING CANT STRIP INSULATION ROOF FACTORY CURB WITH SEISMIC CLIP DETAIL NTS Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 11812 Northcreek Parkway N., Suite 104 Bothell, WA 98011 ph: (206) 682 -6393 fax: (206) 340 -2270 Contractor's License No.: PACIFAC230P8 www. pacificaircontrol.com 8" COLUMN 50' GLB 6 -3/4 "X33" (MEASURED) 8" COLUM OLD LOCATION GP -1 ON 4X4X8'SLEEPER PROPOSED LOCATION OF HVAC UNIT APPROX. 500 LBS TOTAL WEIGHT SEE STRUCTURAL DWG COORDINATE WITH ROOFER RECONNECT TO EXISTING DUCTWORK BELOW IiJ CC uco r rI I Z 0 0 PURLINS CAD 8 4'X8' SKYUGHT 2X12 FRAMING AROUND SKYUGHT 24' 2X4 FRAMING 24" O.C. (TYP.) RIOR CONCRETE WALL TUKWILA COMMERCE SCALE: 1 /8"= 1 0" PARK BLDG REVIEWED FOR CODE COMPLIANCE Vgn Auu 0 201U City of Tukwila BUILDING DIVIRKI J RECEIVED JUL 20 2010 PERMIT CENTER 1FILEPATH: U: \ACAD \PROJECTS\ C W co Z c� W Q r Z 00 W Q J W LLI —� Ce r o- CO r CNI 0 U W 0 0 PROPOSED A A A A DATE 7/20/10 DESCRIPTION PERMIT ISSUE THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL INC. ANY REPRODUCTION, DUPLICATION, ADDRIONS AND /OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER EG DRAWN BY DL AS NOTED DRAWING TITLES ROOF PLAN DESIGNED BY CHECKED BY EG PROJECT NO. T100609 DETAILS SHEET NUMBER M -2 of 2 COPYRIGHT ©2001 PACIFIC AIR CONTROL, INC.