HomeMy WebLinkAboutPermit M10-097 - US BANKUS BANK 151 ANDOVER PK E M10 -097 City oikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 0223100038 Address: 151 ANDOVER PK E TUKW Project Name: US BANK Permit Number: M10 -097 Issue Date: 08/04/2010 Permit Expires On: 01/31/2011 Owner: Name: U S BANK CORPORATE PROPS Address: 2800 E LAKE ST , LAKE0012 55406 Contact Person: Name: JOFFRE SECHER Address: 6802 S 220 ST , KENT WA 98032 Email: JOFFRE @COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425 - 251 -9840 Phone: 425 - 251 -9840 Expiration Date: 06/01/2012 DESCRIPTION OF WORK: REISSUE OF EXPIRED PERMIT M09 -145. REPLACE (1) EXISTING 20 TON ROOFTOP HEAT PUMP WITH (1) NEW 20 TON ROOFTOP GAS PACKAGED UNIT Value of Mechanical: $28,500.00 Fees Collected: $538.81 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009 Permit Center Authorized Signature: JosSid Date: 8-4-10 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe t does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the rfor ance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: 27 Date: .7/jv This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -097 Printed: 08 -04 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://wwwci.tukwila.wa.us Parcel No.: 0223100038 Address: 151 ANDOVER PK E TUKW Suite No: Tenant: US BANK PERMIT CONDITIONS Permit Number: M10 -097 Status: ISSUED Applied Date: 07/21/2010 Issue Date: 08/04/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) doc: Cond -10/06 M10-097 Printed: 08 -04 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. * *continued on next page ** doc: Cond -10/06 M10-097 Printed: 08 -04 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http../Iwww.ci.tulcwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the perfo nce of work. Signature: Print Name:i�I Date: (/ // ! O doc: Cond -10/06 M10 -097 Printed: 08 -04 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. M 10 q 7 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 0223100038 Site Address: 151 ANDOVER PK WE-* C Tenant Name: US BANK Property Owners Name: US BANK CORPORATE PROPERTIES Mailing Address: 2800 EAST LAKE ST. Suite Number: Floor: New Tenant: ❑ Yes m ..No City State Z p CONTACT PERSON — who do we contact when your permit is ready to be issued Name: JOFFRE SECHIER Mailing Address: 6802 S. 220TH ST Day Telephone: (425) 251 -9840 KENT WA 98032 E -Mail Address: joffre @comfortmech.com City State Fax Number: (425) 251 -9871 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: COMFORT MECHANICAL Mailing Address: 6802 S. 220TH ST WA 98032 Contact Person: JOFFRE SECHIER E -Mail Address: loffre @comfortmech.com Contractor Registration Number: COMFOMI015LA City State Day Telephone: (425) 251 -9840 Fax Number: (425) 251 -9871 Expiration Date: 06/01/2012 Zip ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: Mailing Address: State Zip Contact Person: E -Mail Address: H:\Applications\Forn s- Applications On Line\2010 Applications \7.2010 - Mechanical Permit Application.doc Revised 7 -2010 bh City Day Telephone: Fax Number: Page 1 of 2 • • Valuation of project (contractor's bid price): $ 28,500 Scope of work (please provide detailed information): REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP WITH (1) NEW 20 -TON ROOFTOP GAS PACKAGED /J Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas m Other: Indicate type of mechanical work being installed and the quant'ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood /gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipmenc t air handling unit <10,000 cfm 1 incinerator — comm /ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY C - ' TIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF 'E BUILDING 0 Signature: Print Name: BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. UTHQRIZED AGENT: JOFFRE SECHIER Date 6 Day Telephone: (425) 251 -9840 Mailing Address: 6802 S. 220TH ST. KENT WA 98032 Zip IDate Application Accepted: — City State Date Application Expires: 1...). h, 4 Staff Initials: H:Upplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Mechanical Remit Application.doc Revised: 7 -2010 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0223100038 Address: 151 ANDOVER PK E TUKW Suite No: Applicant: US BANK RECEIPT Permit Number: M10 -097 Status: APPROVED Applied Date: 07/21/2010 Issue Date: Receipt No.: R10 -01500 Initials: User ID: WER 1655 Payment Amount: $215.52 Payment Date: 08/04/2010 02:40 PM Balance: $0.00 Payee: DON ULREY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 614093 ACCOUNT ITEM LIST: Description 215.52 Y E 'fi RECF!VED Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 215.52 Total: $215.52 doc: Receipt -06 Printed: 08 -04 -2010 INSPECTION RECORD Retain a copy wick permit M (c) -017 CITY OF TUKWILA BUILDING DIVISION \is”— INSPECTION 0. PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 I (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: US 4 811-Aik Typeol Ilspection: keeili -. . AJkl Addreis: 1 S 1 A-/Jb a ve.r E. Date Calk (La (...._ 1 Special tpstrUctions: — ,.. ._ - . , Date Wanted: . 1 0 —1 2- -(0 a.m. 440 Requester: Wone No: Air Approved per applicable des. Corrections required prior to approval. 'COMMENTS: Air P ..... f, . i 1 • p 1 , 1 , I I . . . : • I . . , „.... . A Insptor: Ik Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. wriphdpaprammv • • At 7%.2.,,••• •TZ.1.Oir 44.5,VP1,--11* • • .46 -OA • A.4 -•• • 4, ••••• • e ‘". AOS INSPECTION RECORD Retain a copy with permit INSPECTIO NO. 1 PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION • ....� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670: - Permit Inspection Request Line (206) 431 -2451 - Project: e. Type of Inspection: Dire c Address: I A-06 oaf L. Date Called: .c .---s. i .►-- pr r Special Instructions: . 4 0 V 1 C) 1 Date Wanted: ] a.m. ' Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Th In pector: i Date: n REINSPECTION FEE REQUIRED: Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. :. +a .. » ,� - • . • -_1 r. s60+..17.25 s VAitIOda INSPECTION NUMBER INSPECTION RECORD Retain- a copy with permit Polio -- ©`l -7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: s k `.. Type of I spection: CA mac -d1,. Address: ) ci Suite #: A p C Contact Person: Tirt4 c.. i. Special Instructions: Occupancy Type: Phone No.: 637 z gg -°) ?' Approved per applicable codes. riCorrections required prior to approval. COMMENTS: 4A - ©k Needs Shift Inspection: - Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: - Occupancy Type: Inspector: C 1. Date: A i', // O Hrs.: / n $80:00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. .. Word /Inspection Record Form:Doc 1/13/06 T.F.D. Form F.I1. 1.13 " ` � 2006 Washington State Nonresidential Energy Code Compliance Form P_roject_Summar_y PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address us BANK Date .11141e1 -009 151 ANDOVER PARK EAST For Building Department Use /rT �i V 1{t+ TUKWILA, WA 98188 Applicant Name: JOFFRE SECHIER Applicant Address: 6802 s. 220TH ST, KENT, WA 98032 Applicant Phone: 425- 251 -9840 FILE C!fPY Permit No.. M (OOq7 REVIEWED FOR CODE COMPLIANCE fiVE JUL 2 3 2010 City of Tukwila BUILDING nifISlfl j RECEIVED JUL 21 2010 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info ' Project Address US BANK Model No.' Date Total CFM 151 ANDOVER BARK EAST SEER or EER For Building Dept. Use ` 615 0 Location TUKWILA, WA 98188 TRANE Applicant Name: JOFFRE SECHIER 8000 Applicant Address: 6802 S. 220TH ST, KENT, WA 98032 Applicant Phone: 425- 251 -9840 Project Description Briefly describe mechanical system type and features. Includes Plans REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP WITH NEW 20 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option • QQ Simple System eartax•S. Q S ystems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location RTO -1 TRANE YFD241 265550 8000 ECONO 11 EER 11.30 ROOF Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 RTO -1 TRANE Y1'D241 324000 8000 ECONO 400000 324000 0.810 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Controls Location of Service A lc 41 l If available. 2 As tested according to Table 14 -IA through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as 'apglicble. ° Flow coptrol types: variable air volume(VAV), constant volume (CV), or variable speed (VS). `"".- 2006 Washington State Nonresidential Energy Code Compliance Form IVlechanical_Summary_(back) MECH -SUM.. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: 4 Constant vol? 4 Air cooled? 4 Packaged sys? <20,000 Btuh? Split system? 4 Economizer included? If Heating Only: 9 Y � 5000 cfm? <5000 � <70 /o outside air? <70% Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only No Yes Heating /Cooling or Cooling Only Reference Section 1421 Yes* Yes • I Reference Section 1423 Simple System Allowed (section 1420) otal Ca . wo economize <240,000 Btuh or 10 %? • Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist. MECH -CHK 2008 Washington State Nonresidential Energy Code Compliance Forma Revised July 2007 Project Address us BANK Date .0,e.9.. The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements iry the Washington State Nonresidential Energy Code. ' /lo Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Mi n.a. 1411.1 Combustion htg. Indicate Intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls n.a. 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum Ml n.a. 1412,3 Humidity control Indicate humidistat yea 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types ml n.a. - 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control n.a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule Mi 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule Mi n. a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling Mi n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems n.a. 1414.1 Duct sealing Indicate sealing necessary n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan Ml n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training Mi yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report ml n.a. 1434 Separate air sys. Indicate separate systems on plans yea Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer rtl SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. . 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover is circled for any question, proviae explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical _P_ermit_Plans_Che.cklist - - - -- - T MECH -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1 G, and it Includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with Input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent Ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (85 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,828 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1438. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. . 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment Is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam Injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include Insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be Isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shell be Insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 1411.4 Packaged Electric Heating and Coo Ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,828 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1438. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. . 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment Is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam Injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include Insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be Isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shell be Insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying tnree or more stones in neE1306 Washington State Nonresidential Eher §9n0250 E r1btyfflimitrecimPThequipment, or 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpolnt and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start -up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall Indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.8 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. with Section 1412.4.1. '— Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1416.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1418 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) *PE ‘11 a PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -097 PROJECT NAME: US BANK SITE ADDRESS: 151 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # DATE: 07 -21 -10 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: C Ailing ivision Public Works n Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07 -22-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 08-19-10 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pryer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL INC UBI No. 601954041 Phone 4252519840 Status Active Address 6802 So. 220Th Street License No. COMFOMI015LA Suite /Apt. License Type Construction Contractor City Kent Effective Date 6/1/1999 State WA Expiration 6/1/2012 Date Zip 98032 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM'010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/19994/30/2012 Active COMFOP*064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 06/01/2005 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Amount JACKSON, HERB J Vice President 01/01/1980 9849307 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS & SURETY OF MD LPM4041162 06/01/2002 Until Cancelled $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 FEDERATED MUTUAL INS CO 9849307 06/01/2010 06/01/2011 $1,000,000.00 05/03/2010 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.00 05/01/2009 6 FEDERATED SERV /MUT INS CO 9849306 06/01/2005 06/01/2006 $1,000,000.0004 /25/2005 5 FEDERATED MUTUAL INS CO 9849306 06/01/2004 06/01/2005 $1,000,000.0004 /30/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/Ini/bbip/Print.aspx 08/04/2010 kg King County Assessor information for parcel number 0223100038 Taxpayer name Mailing address U S BANK CORPORATE PROPS 2800 E LAKE ST LAKE0012 MINNEAPOLIS MN 55406 Addresses) at this parcel 161 ANDOVER PARK E 98188 Parcel number 0223100038 Tax Account number 022310003805 Levy code 2390 Jurisdiction TUKWILA_ Present use Bank ~T Appraised value $920,200 Legal description ANDOVER INDUSTRIAL PARK # 2 LESS W 402.01 FT LESS N 235 FT ASSESSOR DATA 3a 1 • tam, .. ,r. k. 0723000030 0213101.11W.N ---•F---- -- .] 0223100037 0223 10 00 34 0223100031 0223100032 0223100070 0227100077 I 0223100036 0727000060 N. 0227000067 02231000Q 0227100086 0223100007 0227100000 0221100000 0223/00022 1012001 KY.10• / _ .. n�.• ,0e tn' Th.Jnfartutlgn yclue.d ond�.4,tnw Fu u.ln va!�o�r�^a Courw.fillm .naW dwwus sndL subFhclmmMO r10,adnaic.,.l0nry7�. tt,TC ;a ppkl h 1,1141 ar4 014 11 ..t of tmpll.a</r to ixun 0,1,2elgaM... x V � a' .1,,AnI io. .1 • {� `'F . t+ �7 fi • {2A m Arno(ar.a.amra +,l..e..yaadu<ea cau�tlrh. mtw.r°e'r,rx.�a•Nro w.a.tFdw. ° \� KIpg County' d�In.0••10a Aol 10 ,.y.lini.or le.t sr..N �0 11NMR Wwo l.d w �4+d3n Cie h. • �^}' e1 ! i tl n nv 1. f hD0s01�te..6 ..Iet0nY0 .•'� N irk oo s�ppyµt q�,. p. �g F 19 011/c ' it:Ii2 )+$'W! .C'!"t x..11 T' ; `Y,�, ': i.a =. Nl.h ..S v?^t'..+ti��i ttig liter:.. t7.. 0/2001,1. c i0 14M41,110.1,111t9:01 SITE PLAN Map of 151 Andover Park E Tukwila, WA by MapQuest Page 2 of 2 VICINITY MAP HVAC Equipment Schedule (New) # Brand Model Ton Total CFM OSA CFM Econo. SP 0.5 Cap. Cool 265,550 EER 11 Btuh -In 400,000 Btuh -Out` 324,000 AFUE 81 Weight 3228# 1 Trane YFD241 20 8,000 1600 0 -100% HVAC Equipment Schedule (Existing) # Brand Model Ton Total CFM OSA CFM 1600 Econo. 0- 100% SP 0.5 Cap. Cool 240,000 EER 8.3 �Btuh -In Btuh-Out AFUE Weight 3375# 1 Lennox _ CHP11 -2753 20 8,000 EQUIPMENT SCHEDULE PROJECT DESCRIPTION: 1. REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP UNIT WITH NEW 20 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER. 2. EXISTING AIR DISTRIBUTION BEING REUSED "NO WORK ". 3. PROVIDE AND INSTALL NEW 7 -DAY PROGRAMMABLE THERMOSTAT. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 4. ROUTE CONDENSATE TO SPLASH BLOCK. 5. PROVIDE COMMISIONING REPORT WITH OPERATIONS AND MAINTENANCE MANUALS. 6. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 7. ALI. DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. ROOF ACCESS O 1.5" GAS LINE TO METER 110' TO METER RTU -1 ROOF PLAN (NTS) SEPARATE PERMIT REQUIRED FOR: Oi4eChanical BITElectrical ❑ i umbing Er Gas Piping City of Tukwila RA DING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE C4 PY Permit No. IA 10- Oct , Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize t� violation of an . opted code or ordinance. Receipt of approved Fie y an itions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APP Imo JUL 232010 A iL City of Tukwila BUILDING DIVISION 97 RECEIVED JUL 212010 PERMIT CENTER 1 REVISIONS HVAC Service & C a. g DATE: SCALE: • DRAWN I CHECKED: 1 Voyager YCD Items: YCD_ -1 (This item Is not 'In Job') 7/13/2009 8 :21:20 AM Comfort Mechanics! - WFB Tukwila Aft- TRANS. CL k(f-Att CORNER WEIGHT INSTALLED OPTIONS NET WEIGHT DATA Accessory Accessory Economizer 80.0 Ib Motorized Outside Alr Damper Cooling Capacity (Btuh) Manual Outside sir Damper Rated load amps (total) Oversized Motor 28,800 High Efficiency Motor EER (Btuh /Watts) High Static Drive 229/229 (468.0) Thru the Base Electrical 8.3 Urit Mounted Circuit Breaker High Temperature Hosting Ratings Ur.it Mounted Disconnect 240.000 Pcwer Exhaust 95,0 Ib Hinged Doors 13.2 Zone Sensor 2.8 LPG Conversion Kit . . Low Temperature Heating Fatinge Powered Convenience Outlet 134,000 Adapter Curb 850.0 Ib BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITY SHIPPING NET OA Slags 1 0 p© E F t2580.0 lb 2203.0 Ib 701.0 Ib 575.0 Ib 421.01b 504.0 Ib 57" 35" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT MUST BE ADDED. RIGGING AND CENTER OF GRAVITY TOPSS Dimeiision Drawing ALLW ELHTS AND DI4ENSANS ARE APPROXI4ATE. CERTFED PRIITS ARE AVAIABLE UPON REQUEST. Page: 4 WEIGHT DATA (NEW UNIT): BASE UNIT: ECONOMIZER: POWER EXHAUST: ADAPTER CURB: TOTAL W /ACC: #2203 #80 #95 #850 #3328 ").4 SPECIFICATIONS Model Number CHP11 -2763 Line voltage data - 80 Hz - 3 phase •ARI Standard 340 Ratings Cooling Retinas Cooling Capacity (Btuh) 240,000 Rated load amps (total) Total unit watts 28,800 20.4/20.4 (40.8) EER (Btuh /Watts) 8.30 229/229 (468.0) Integrated Part Load Value 8.3 Full load amps (total) High Temperature Hosting Ratings Total capacity (Btuh) 240.000 Locked rotor amps (total) otal unit watts 24,700 13.2 C.O.P. 2.8 5 Low Temperature Heating Fatinge Total capacity (Btuh) 134,000 5 Total unit watts 18,700 17.6 C.O.P. 2.1 22.0 Refrigerant (22) charge Slags 1 34 lbs. 0 oz, 100.0 Stage 2 31 lbs. 0 oz, 127.0 Indoor Coil Blower and Drive Selection Blower wheel nominal diameter x wid h (in.) 15 x 15 (No.) Horsepower sectary Installed 1Drlvoa Nominal motor horsepower 6 Full load amps (total) Maximum usable horsepower 6.76 2.2 Voltage & Phase 200 /230 /480v3ph ' RPM range 790 - 965 (tte00 - 760) Less Exhaust Fans Optional Factory Ina tatted itl;ives Nominel motor horsepower 7.1/2 150 Maximum usable horsepower 8,63 With Exhaust Fens Voltage & Phase 200/230/460v -3ph 150 RPM range 900 - 1070 70 Indoor Coil Net fats area (sq. R.) 23.5 ,87 Tube diameter (in.) & No. of rows 1/2 - 4 ,88 Fins per. Inch . 15 .88 Outdoor Coll Net (ace area (sq. ft,) 38.9 .88 Tube diameter (in.) & No. of rows 1/2 - 4 Leas Exhaust Fans . Fine per Inch 15 115.0 Outdoor CoII Fans Diameter (in,) & No. of blades (2) 26 - 6 With Exhaust Fans Alr volume (chit) 12) 8800 119.0 Motor horsepower (2) 1 65.0 Motor watts (2) 1000 141,000 Condensate drain size mpt (in.) (2) 1.1/4 No. & size of filters (k-.) ill) 16 x 20 x 1 45.0 Net weight of basic unit (lbs.) (1 Package) 2900 Optional Electric Heat Model 14o. ECH11 -275 41.7 kw Input range 30 -45-80 -75-90 285.0 210 Optional Roof Mounting Frame - (Net weight) Standard RMF11 275 (315 lbs.) 4 Horizontal RMFH11 -275 (440 lbs.) 172,000 Optional Economizer & Controls - (Net weight) REMD1iM -275 (290 lbs.) tECH11- .275 -85 Optional Gravity Exhaust Dampers - (Net weight) GED11 -275 (30 lbs.) 55.1 • Optional Power Exhaust Dampers Mod& No, - (Net weight) PED11 -275 (150 lbs.) (145 lbs.) Exhaust Fans Diameter Iin.) & No. of blades (3) 18 - 6 204,800 Total air volume (clm) 7050 Motor horsepower ( (3) 1/4 50.4 Watts Input (total) 1100 .Option:r ..^eiling Supply and Rerurn Air Diffusers (Net weight) Step-down RTD11 -275 (403 lbs.) 55.1 Flush FD11.275 (363 lbs.) 151.0 Transition SRT11 -275 (80 lbs.) 480 Optional Fresh Air Oer *,per & Filter Size (in.) - (Net weight) OAD11.275 (115 lbs.) 1 - 28 x 31 x 1 Optional Automatic OAD11 Damper Kit - (Net weight) 88613 (15 lbs.) Electrical characteristics 200 to 480 volt - 60 hertz - 3 phase 177,700 'Rated In accordance wrci ARI Standard 340. Cooling Rating■ - 95'f outdoor air temperature and 90 °F db /67 °F wb entering Indoor coil sir, minimum external duct static pressure. High Temperature Hearing Ratings - 47°F db /43 °F wb outdoor air temperature and 70 °F db entering indoor coil alt. Low Temperature Heating Ratings - 17 °F db /15°F wb outdoor air temperature and 70 °F db entering Indoor colt elr, )Using total air volume a•ud system static pressure requirements, determine from blower performance tables rpm end motor output required. 1tMotor pulley furnished with unit for field Installation. If required. WEIGHT DATA BASE UNIT: ELECTRIC HEAT: ECONOMIZER: EXHAUST DAMPER: TOTAL W /ACC: (EXISTING UNIT): #2900 #155 #290 #30 #3375 - 31( - ELECTRICAL DATA Model No. CHP11.2753 Line voltage data - 80 Hz - 3 phase 200V 230V 460V Compressors (2) Rated load amps (total) 39.5/39.5 09.0) 39.5/39.5 (79.0) 20.4/20.4 (40.8) Locked rotor amps (total) 229/229 (458 .0) 229/229 (468.0) 116/118 (232.0) Outdoor Coil Fen Motors (2) Full load amps (total) 12.8 10.4 6.6 Locked rotor amps (total) 30 28 13.2 Indoor Coll Blower Motor Horsepower 5 7.1/2 • 5 7 -1/2 5 7 -1/2 Full load amps 17.6 25.3 15.2 22.0 7.8 11 Locked rotor amps 100.0 160.0 90.0 127.0 45.0 64.0 Optional Exhaust Fan Motors (No.) Horsepower (3) - 1/4 (3) - 1/4 (3) - 1/4 Full load amps (total) 4.2 . 4 2 2.2 Locked rotor amps (total) 9 8 9 8. 4.9 Recom. max. fuse size (amps) Less Exhaust Fans 150 150 150 150 70 • 70 With Exhaust Fens 150 150 150 ' 160 70 70 Unit Power Factor Less Exhaust Fans , :•: ,87 .88 .87 ,88 .87 With Exhaust Fens .88 ,87 .88 .87 .88 .87 °Minimum Circuit Ampeclty Leas Exhaust Fans . 120.0 127.0 115.0 122,0 80,0 63.0 With Exhaust Fans 124.0 132,0 119.0 126.0 82.0 65.0 •rtsfsr to National Electrical Code menu:,! to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus and minus 10% of lino voltage. OPTIONAL ELECTRIC HEAT DATA Electric Heat Motet No. & Net Weight No. of Steps Volta Input kw Input Btuh Output Total Unit & Electric Heat Minimum Circuit AmpacIty Shp 7-1/2 hp 200 20.8 71,000 201,0 209.0 210 23.0 78,500 2 220 25.2 ::,000 1 tECH11- 275 -30 eriaa�r 0M0 W W 230 27.5 93,900 209.0 215.0 (135 lbs.) 240 30.0 102,400 440 25.2 86,000 1 460 27.5 93,900 105.0 108.0 480 30.0 102,400 200 31.3 106,800 238.0 248.0 210 34.5 117,700 3 220 37.8 129,000 t ECH 11-275-45 230 41.3 141,000 252.0 259.0 (145 lbs.) 240 45.0 153,800 440 37.8 129,000 2 460 41.3 141,000 126.0 130.0 480 45.0 153,600 200 41.7 142,300 277.0 285.0 210 46.0 157,000 4 220 50,4 172,000 tECH11- .275 -85 230 55.1 188,100 297.0 304.0 (145 lbs.) 240 60.0 204,800 440 50.4 172,000 2 460 55.1 188,100 148.0 151.0 480 60.0 204,800 , 200 52.1 177,700 318.0 326.0 210 57.4 196,000 5 220 63.0 215,000 tECH11- 275-76 230 68.9 235,000 342.0 349.0 (155 lbs.) 240 76.0 255,900 440 63.0 215,000 3 460 68.9 235,000 169.0 173.0 480. 75.0 255213,,900 tECH11 -275 -90 6 200 62.6 300 (155 lbs.) 210 68.9 235,000 357.0 385.0 'Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 °F. 1May be used with two stage control. -31g - M11 • 09 � - REVIEWED FOR CODE COMPLIANCE APP O JUL 2 3 2010 - City of Tukwila BUILDING DIVISION RECEIVED JUL 212010 PERMIT CENTER REVISIONS 3RPORATEI rice & Constn h Street - Kent, Washington 98 5) 251 -9640 •Fa= (4250 251 -98 1 ra eriaa�r 0M0 W W . D CL 0) It 1 W ai N DATE 1 SCALES DRAWN CHECKED8 •