HomeMy WebLinkAboutPermit M10-101 - CONTINENTAL MILLSCONTINENTAL MILLS 18100 ANDOVER PK W M10 -101 City (*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 3523049121 Address: 18100 ANDOVER PK W TUKW Project Name: CONTINENTAL MILLS Permit Number: M10 -101 Issue Date: 09/23/2010 Permit Expires On: 03/22/2011 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: ANDREA HOVEY Address: 9322 14 AV S , SEATTLE WA 98108 Email: AHOVEY @PSFMECH.COM Contractor: Name: PSF MECHANICAL, INC. Address: 9322 14TH AVENUE SOUTH , SEATTLE, WA 98108 Contractor License No: PSFMEI *090NZ Phone: 206 - 812 -7670 Phone: 206 764 -9663 Expiration Date: 10/03/2011 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF A BUILDING PRESENTLY UNDER CONSTRUCTION. (2) 20 TON ROOFTOP COMPUTER ROOM UNITS. ELECTRIC VAV FAN TERMINAL UNITS WITH LOW VELOCITY DISTRIBUTION DUCT WORK AND DIFFUSERS. Value of Mechanical: 547,000.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $5,517.56 International Mechanical Code Edition: 2009 Date: —1 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name III % 7'# Date: 9 This permit shall become null and void if the work is not - enced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe: IMC -4/10 M10 -101 Printed: 09 -23 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http. //www.ci.tukwila.wa.us Parcel No.: 3523049121 Address: Suite No: Tenant: 18100 ANDOVER PK W TUKW CONTINENTAL MILLS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10 -101 ISSUED 07/28/2010 09/23/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of'Ikwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed m accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) doc: Cond -10/06 M10-101 Printed: 09 -23 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http:/lwww.ci.tukwila.wa.us 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -101 Printed: 09 -23 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http. //www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: / /.1•Ar • r e/i7 6e Jr Date: 9 ~a --/D doc: Cond -10/06 M10 -101 Printed: 09 -23 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. tit (0- 0( Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 8100 Andover Park West Tukwila, WA Tenant Name: Continental Mills King Co Assessor's Tax No.: 3S)-30 L1 ` a u-I Suite Number: New Tenant: Property Owners Name: Segale Business Park Mailing Address: 8100 Andover Park West Tukwila Floor: m Yes ❑..No WA 98188 Zip City State CONTACT PERSON — who `do we contact when your permit is ready to be issued . Name: Andrea Hovey Mailing Address: 9322 14th Ave S Day Telephone: (206) 812 -7670 WA 98108 E -Mail Address: ahovey @psfinech.com City State Fax Number: (206) 812 -7671 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: PSF Mechanical, Inc. Mailing Address: 9322 14th Ave S Contact Person: Same as above Seattle WA 98108 E -Mail Address: Contractor Registration Number: "'r mcelsk 01,0 Na_ City Day Telephone: Fax Number: Expiration Date: State Zip to ■99 ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: State Zip E -Mail Address: ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: PSF Mechanical, Inc. Mailing Address: 9322 14th Ave S Contact Person: Joel Smith Seattle WA 98108 E -Mail Address: jsmith @psfinech.com H;\Apphoations\Fonns- Applications On Line\2010 Applmattons\7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh City State Day Telephone: (206) 826 -3560 Fax Number: (206) 826 -3561 Zip Page 1 of 2 • • Valuation of project (contractor's bid price): $ 547,000 Scope of work (please provide detailed information): Tenant improvement of a building presently under construction> 2 - 20 ton rooftop computer room units. Electric VAV fan terminal units with low velocity distribution duct work and diffusers. Use: Residential: New ❑ Replacement ❑ Commercial: New m Replacement ❑ Fuel Type: Electric m Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical eqgheuipp ment air handling unit <10,000 cfm 2 incinerator — comm/ind Electric VAV Fan terminals 67 PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: An ea Hovey Mailing Address: 9322 14th Ave S Date: 1 (a I Day Telephone: (206) 812 -7670 Seattle City WA 98108 State Zip Date Application Accepted: �� t Date Application Expires: Staff Initials: Ki% H \Applications \Forms - Applicanons On Line \2010 Applications \7.2010 - Mechanical Permit Apphcation.doc Revised' 7 -2010 bh Pagc 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049121 Permit Number: M10 -101 Address: 18100 ANDOVER PK W TUKW Status: APPROVED Suite No: Applied Date: 07/28/2010 Applicant: CONTINENTAL MILLS Issue Date: Receipt No.: R10 -01897 Initials: WER User ID: 1655 Payment Amount: $4,414.05 Payment Date: 09/23/2010 03:47 PM Balance: $0.00 Payee: PSF MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 014478 4,414.05 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 4,414.05 Total: $4,414.05 doc: Receiot -06 Printed: 09 -23 -2010 r • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: hup://www.ci.tukwila.wa.us Parcel No.: 3523049121 Address: 18100 ANDOVER PK W TUKW Suite No: Applicant: CONTINENTAL MILLS RECEIPT Permit Number: M10 -101 Status: PENDING Applied Date: 07/28/2010 Issue Date: Receipt No.: R10 -01435 Initials: User ID: Payee: WER 1655 Payment Amount: $1,103.51 Payment Date: 07/28/2010 01:26 PM Balance: $4,414.05 PSF MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 014460 1,103.51 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,103.51 Total: $1,103.51 doc: Receiot -06 Printed: 07 -28 -2010 • ; 7-■ 4" ," • " ' • y 40. • .1.. • s • • . INSPECTION RECORD Retain a copy with permit AV-. /CI INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: (26tAfr/A/6701- ifna- S Type of Inspection: r/A1,9/....- Address: /f'/040 x2A/ 4>a/le /21‘4/ Date ailed: Special Instructions: Date W4nted: g / - - .2 0 -/ / ‘,n. • • Requester: Phone No '/25 -245 Seel Approved per applicable codes. El Corrections required prior to approval. COMMENTS: , ar)voiedyi-_-,,ti. In ector flR 444447 /\\/\4,44A/ Date: 9-0-/1 SPECTION FEE REQUIR 1 D. Prio to next inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. - AtAtilfittnabcft-krIxernmeaciihettaAtstew • • INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 981i88 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ln/0 - /©/ 41. Project: aexirfiJEti/TA-L if 2L., Type of Inspection: .SMDAeg .54/2/r .. Cc//L Date Called: G(-} Address: / A /D D /9.06OV,4 14>/' Special Instructions: 7 q.1-1 Date Wanted: ' -J D —// fl. p.m. Requester: • Phone No: • '925'- 7 '✓'r o / Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Inspector; l Date: NSPECTION FEE REQ RED. Pri o r to next inspection. fee must be id at 6300 Southcenter B vd.. Suite 100. Call to schedule reinspection. 4. INSPECTION NO. INSPECTION RECORD Retain copy with permit PERMIT NO. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • Project: O ,7 M wm jit4I Type of Inspection: 7/e7- Address: Date Called: Special Instructions: ' Date Wanted: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. z COMMENTS: 0 PI-44 'i s t rtIllI /� "S (/ 161-e Rm h —a)/ A . 77;,g-71 to /x/+34-2, 4 IN 1. PECTION FEE REQUIRD. Prior fo next inspection, fee must be at.6300 Southcenter Blv .. Suite 100. Call to schedule r4 inspection. Date: — 3 /r M.sr .1 711 .. • • . re %VFW - • • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. �.. CITY OF TUKWILA BUILDING DIVISION 6300 St uthcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 J tO -1O( Proj t: ' Art � /� "igt Inspection: Type of , �^- (*TAO r 0 U Cr 4f- ✓�[�/ Address: ,/ •o .'._, A•>I� OV rr 1A�! Date Called: /ford 4 , S ecia nstructions: . 04,P 54-61 NN Date Wanted: r'" _31—I/ .r.3433-. p.m. Requester/ .M . /4. Z3� a44V 2 /? , / GI /24/ . Phone No:. 249 6 A 5"o -4 Vet I • Approved per applicable Codes.. IN Corrections required prior to approval: • COMMENTS: . . / . 'if 17 rZ 4,1 ; Al A/ eel� ,th _ 3 -?' i rb! r ,rj T .1J,r' , +/' 7 /4. Z3� a44V 2 /? , / GI /24/ . ,'. r 1 1— 52/.6015, 4, Ae tom:// /671/-7,94=4.004-- 1 6 butt" ...pasustriibvii -,4/44,0y, .m • Inspect : ti / -r7 .a.e A �/: w (Date: + A. 4 14".... /}/ INSPECTION FEE RE UIRED. Pri to next inspection. fee must be ' paid at 6300 SOpthcenter 1vd., Suite 100. Call to schedule reinspection.• °- .411V71. • • .....sae••. avµ I':vn..:.. ^s• raear. - INSPECTION NO. INSPECTION RECORD Retain a copy with permit 'M ' f"Q_Q 1 PERMIT NO. .CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila: WA 98188 a (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 •Pect: M115 Type�Ajf Inspection+ A.•ress: 0 A-J (e! ,a '�l V!1 Date Called: Special Instructions: Date Wanted: a.m. i c&- Requester: Approved per applicable codes. Phone No:! .5 0 Corrections required prior to approval. COMMENTS: 7 A. 1 PECTION FEE REQURED. Prior to n xt inspection. fee must be t 6300 Southcenter Bl ,d.. Suite 100: 11 to schedule reinspection. - .� sa:ti:an r • k- INSPECT ON NO. ' INSPECTION RECORD Retain a copy with permit! " r x PERMIT ND. ;CITY OF TUKWILA BUILDING DIVISION '_ 6300 Southcenter Blvd:; #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection, Request Line (206) 431 -2451 Project: rZ Af /A„094 Al ; / /S. Type of Insp ctiop: -is . *7 /G / - Address: ) li'd' 4/1/ad VCR 117g k/ _ Date Called: _ _ _ ,, Special Instructions: • Date Wanted: � / —iz — / © £m. cep, Requester: Phone No: Approved per - applicable codes: ElCorrections required prior to approvaj. COMMENTS: Prr /s-t- - / / bV J Z-A/SZ' 'T"F INSPECTION FEE REQU,REb. prior tnext inspection. fee must be .paid at 6300 Southcenter Blvd:; S).nte 100. Call to schedule reinspection. INSPECTION NUMBER 444 undo r' P IINSPECTION RECORD Retain a copy with permit Sri F ast, Tukwila, PERMIT NUMBERS DEPARTMENT a. 9 ,nti-S74 -44n, Project: C a a-4i 4 e 4 id 1 f ' ` ' Type of Inspection: Hood & Duct: Address: /6100 14.Pr Suite #: r F Contact,P oh: 1, J 6J4f4 - , ." eye, Special Instructions: i fy Phone No.: f''} � r R,:-",1 per applicable codes Corrections required prior to approval. COMMENTS: Sprinlders Hrs.:. Fire Alarm: Hood & Duct: Monitor: Pry -fire: F Permits: Occupancy Type: , i < f''} / • co ft .%) b. `i< 9? - ,"".. -1 :: p , -7 .1. �7j i i .1r E pp w ,,,,,, : ' I 1 t'1'ct'i Lp 4} e -^^ ii?�; rift 6<r; d�,rlf.>, <r'a Cig` L 31 *O �e✓ Sf'14/ L� l}- _bg'6i3 ii t. ijVa. ! " ' P Af ".„.-4 ,, �+sermaI f Needs Shift Inspection: Sprinlders Hrs.:. Fire Alarm: Hood & Duct: Monitor: Pry -fire: F Permits: Occupancy Type: , Inspecto r: °,+;`i ,..Y'5 I Date: 2 , 0 ii) Hrs.:. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection: Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Aug i4 20:0 01:07:09 PM SHEET SIZE: 11017 FILE COPY ernOt No. 40 EMBEDS 4312M REVIEWED FOR CODE COMPLIANCE AODOr9VED kr' 2 1 Anil City of Tukwila BUILDING DIVI4lfl ' ,CEIU aoF�i LA CORRECTION SEP 1 At , 1to LTR' KERMIT CENTEF FOR PRODUCTION 08 -14 -10 NEN SHEET 08-06 -10 BILL OF MATERIAL 1Lut. 400 REFERENCE: 01! I P15:5 011 H,,ght tot al Mark 40 43124 40113124 unit D5uriptmo Langth Remarks Ihlt DIED 10 83156 A38 80 539 4534 A108 E401 KD STEEL INC 7004 N Altamont, Suite A Spokane, WA 99217 PH 509 - 467 -5309 FAX 509- 466 -0403 NOTES HOLE DIA U.N.O. = 1546 WELD - Lq FILLET UND (E70XX) SURF. PREP.- HAND TOOL CLEAN FINISH = NONE COL BASE PLATES ARE ALWAYS SECTION CUTS LOOKING DOWN H.P. (FAILS) DETAILING: JOB NO 2147 FABRICATION TECHNICAL SERVICES, INC. 307 N Lincoln, Ste. 8, Post Falls, ID 83854 (208) 457 -8282 fax: (208) 457 -8208 REVISIONS 50 MR 1 2 �m SEGALE 2 STORY OFFICE BUILDING 3 0511(5"194 SEGALE PROPERTIES PM °" SS 010o -15 -10 4 5 MECH CURB q 1009 431211 • 2- . (2 Er.) G OE 42 M. OE aMi jrif' lEMEINSA i IYPE 'Ar FIN (NN0 82!4.400) TYPE 'AI' PIN (YNM BOlURAO) . e;' NW. (61' UAL) M. SIMILAR COND, CRO. • TOP ! PER 5E01108 0 -4.2 00.01. PER SECT. 21-4.2 0 MILLER BEMIS CO.CRETE WALL PER OVATIONS NECK. IROT ELEVATIONS @ WEST CANOPY v e K . r f Y 6m/iv O 5 "107-. ,Z3e79A. so Le IX aN CONK. OE UNIT I0 CMS PEA IoI. M. E. • e'.. NAIL �H. 0 Inc Ie 0. REMO. 00 TOP OF 0!. BEAN AT NCR VALLEY M. 34.44 (P . 0 12•.0/ 0 EA. WAY M It 1• j (W1M P2 ROM) SECTION A -5.4 I.. 1.-0. PER ARC*. NY. •01t8. 0 TOP . YEONNPC& R YPR. PER ARCH. (P• -0' NO) MT' •/ 24000. um.) : \ PROROE .1' -0' ! ./2 -1.4 -1 r 9215 b e•CAna 1002.4 -e0 00 (f .Nix) MAL WOO. FOR KM. PER SESCOW N -1.t _1:KM. i47.1 IF.TILAW1-1 PM.,C 2.0 • MAKE OPENINGS PER M. OPENING SYPP4R DETAILS. SHEET SI.0 M. SREE MAY PER PLAN C00l4L7l4N PER 5EC1100 0 -4s • 0 -3.2 TOP OP-_� ROD, 3' (NY.) ME 'AI' PIN (1140 14240010)- .2221 T. ! is40• -1' ! • nob) DOLT '11 but 0ss. 5.51 PER PLAN i'.P' Sown 10. ! 0'0 SC0mN2 40 STD. MS SASE, M (PER PIA01 0 ..1P_Elt KAM WC 1 M. ;role VTR. 10 • CONNECT a- S1FS ! EE SCR Ali KW 4)-�Y 801.15 0:011. • 013.13S PER SECTOR Y -4.2 (E4TE.8 0193 9.0111) C. OfCON ! FA SVC PER 014... -1 (PER/. 2EIW ROT 540001) 11188000 5400 COPE ONE SIDE E) ./ rs 4.01102.! DTL. a -1 SECTION E-5.4 CORN. PER SECT. 0 -3.1 L•\2002II14•\02090\SCEN2 00210! III24b*6 -S3.4- C00PY PANps- Re- 070W.1.5, 04- 29-I0. Ilnb, 44.0029. 90 SECTION )- F -5.4 1. 1•_11. 30250 PER PLA0 BOIL MINIS ON POST M. (SEE PLAN) SECTION 1 STEE4. BL DTL._ RAH PER DTL. SECTI 2 1 c n1141w:m .PI T..: S i l.1 1 r /i • TOC 30' -fl' • • MEMORANDUM To: Jennifer Marshall Date: 09/10/10 Company: City of Tukwila Project: Continental Mills TI From: B Joel Smith on behalf of Andrea Hovey Location: Tukwila, WA Subject: Correction Letter#1 Revision Project #- Memo#: 1922 -008 Summary of Revisions: 1. The proposed fan powered terminal unit system will need to comply with section 606.2.2 of the 2009 International Mechanical Code. Please show method of compliance with this section. The method of compliance is section 606.2.2 exception 1. We have shown smoke detectors on the return air of the rooftop units and smoke detectors at the return air on each floor. The fan terminals will turn off if any detector if activated. This smoke detectors are now shown on the drawings. 2. Please show structural connection details for attaching AC -4 and AC -5 to the roof structure. We have included a detail on Mechanical Drawing M -103 and some additional information with this memo. 3. Although the two main HVAC units are included in another permit, this permit will include the rest of the systems. These two systems will require smoke detectors to shut the system down per section 606 MC. These detectors may be included in the shell mechanical permit but testing will most likely be required after the system is complete. The location of the detectors will need to be shown on this permit and it would be OK to reference the shell permit if they are to be installed under that permit. We have shown the location of the smoke detectors in the return air of AC -1 and AC -2 as shown of the Shell and Core drawings. This revision is on M -103. 4. Change code references to 2009 MC and Energy codes should remain 2006 as their adoption has been delayed. The code references have been changed on M -001. Copy to: Andrea Hovey -PSF, Randy Stabnow -PSF , Robert Willis -PSF "Trusted to be the Better Choice" PSF Mechanical, Inc. 9322 14th Avenue South Seattle, WA 98108 -5102 T 206.764.9663 F 206.762.8381 psfmechanical.com 1 City of T��Mr ° ila • Jim Haggerton, Mayor Department of Community Development August 16, 2010 Andrea Hovey 9322 14 Av S Seattle, WA 98108 RE: Correction Letter #1 Mechanical Permit Application Number M10 -101 Continental Mills — 8100 Andover Pk W Dear Ms. Hovey, Jack Pace, Director This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ifer Marshall it Technician encl File: M10 -I01 W:\Pennit Center \Correction Letters \2010\M10 -101 Correction Letter tl1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: August 12, 2010 Project Name: Continental Mills Permit #: M10 -101 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The proposed fan powered terminal unit system will need to comply with section 606.2.2 of the 2009 International Mechanical Code. Please show method of compliance with this section. 2. Please show structural connection details for attaching AC -4 and AC -5 to the roof structure. 3. Although the two main HVAC units are included in another permit, this permit will include the rest of the systems. These two systems will require smoke detectors to shut the system down per section 606 IMC. These detectors may be included in the shell mechanical permit but testing will most likely be required after the system is complete. The location of the detectors will need to be shown on this permit and it would be OK to reference the shell permit if they are to be installed under that permit. 4. Change code references to 2009 IMC and Energy codes should remain 2006 as their adoption has been delayed. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. PO PERMIT C;fi c • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -101 DATE: 09/14/10 PROJECT NAME: CONTINENTAL MILLS SITE ADDRESS: 18100 ANDOVER PK W Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMEN ui ding Division El Public Works Fire Prevention Structural Planning Division UPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete yg° Comments: Incomplete DUE DATE: 09/16/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TOES /THURS ROUTING: Building Please Route IX Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: DUE DATE: 10/14/10 Approved with Conditions ISZi Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • y + • jqi fit. �u # ; 7 �, i�t� �� f � - 4�'{�i!t.'r,�„� .f.l.T ' J Lr" fY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -101 DATE: 07 -28 -10 PROJECT NAME: CONTINENTAL MILLS SITE ADDRESS: 18100 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued D-E� PA THE TS: Bu' din 'vision Public Works Mk 4wc -3-fD Fire Prevention Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07 -29-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -26-10 Approved Approved with Conditions n Not Approved (attach comments) t% Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: MilttAt9 Departments issued corrections: Bldg' Fire ❑ Ping ❑ PW ❑ Staff Initials:�`� Documents /routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: hrtp: / /www.citukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 9/10/10 Plan Check/Permit Number: M1 0- 1 0 1 ❑ Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Continental Mills Project Address: 1 8100 Andover Pk W Contact Person: Joel Smith CITyui SEP. pemacianza Phone Number: 206.825.3560 Summary of Revision: See the attached Correspondence Memo 1922 -008 for responses to all the comments. See detail 1/M103 on the drawings and the attached sheets for rooftop structural connection details Sheet Number(s): All Permit Revisions are noted with a delta 1 and are clouded "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Jf�p(V Entered in Permits Plus on lapplications\forms- applications on linclrevision submittal Created- 8 -13 -2004 Revised: Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name P S F MECHANICAL UBI No. 601318369 INC Phone 2067649663 Status Active Address 9322 14Th Ave S License No. PSFMEI'090NZ Suite /Apt. License Type Construction Contractor City Seattle Effective Date 8/9/1991 State WA Expiration 10/3/2011 Date Zip 98108 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EDENN "225LKEDEN NURSERIES Construction Contractor General Unused 6/12/1978 6/1/1986 Archived Business Owner Information Name Role Effective Date Expiration Date BEARDSLEY, WARREN S Cancel Date 01/01/1980 Bond Amount CRITCHLOW, JAMES D 4 01/01/1980 08973126 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIDELITY Et DEPOSIT CO OF MD 08973126 08/08/2009 Until Cancelled $6,000.0007/10/2009 /07/2009 3 HARTFORD FIRE INS 52BSBFA6327 08/08/2008 Until Cancelled 08/08/2009 $6,000.00 07/08/2008 2 FEDERAL INS CO 81241859 08/08/2001 08/08/2008 $6,000.0010/01/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 17 WAUSAU BUSINESS INS CO TBJZ91452741029 10/01/2009 10/01/2010 $1,000,000.0010 /07/2009 16 WAUSAU UNDERWRITERS INS. CO. TBJZ9145274109 10/01/2009 10/01/2010 $1,000,000.00 09 /28/2009 15 TRAVELERS PROPERTY CAS INS CO DTEC0527D0578TIL08 10/01/2008 10/01/2009 $1,000,000.00 09/23/2008 14 ZURICH AMERICAN INS CO CP0399986500 10/01/2006 10/01/2008 $1,000,000.00 09/14/2007 13 ST PAUL FIRE & MARINE INS CO DTEC0526D8294TIL05 10/01/2005 10/01/2007 $1,000,000.00 09/18/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 09/23/2010 q "' r; I' 1 \i 4k lc f /$ ii' t� i..3 )ie t} M i 1 t 33 1 .::..:i. - 7.;:.i _..a.— .P..,r.1`ici..'�i'n- ,w. ::. 4, .. .?aa?:2ti'.�.. -w..`> ,rr r,5-4:7- ..re.;`. -a :=74.1".rs:7,;.:: .yr-r...- arb-i.e?. :. .?. .'.w-n. .'^,- - .. `l0i Department of Licensing Office of the Secretary of State Master License Service Corporations Division LEGAL ENTITY REGISTRATION Unified Business ID #: 601 318 369 Business ID #: 1 Expires: 05 -31 -2011 PSF MECHANICAL, INC. 500 GALLAND BLDG 1221 SECOND AVE SEATTLE WA 98101 2925 Domestic Profit Corporation Renewed by Authority of Secretary of State REGISTERED TRADE NAMES: PSF MECHANICAL, INC By accepting this document the licensee certifies that information provided on the renewal was complete, true, and accurate to the best of his or her knowledge, and that the company will stay in 4T -VC,& a. C p 1. '. riX :J 1 i 'k f, i. l i %S a{ s. - 7� L 'I �l aZ compliance with all applicable Washington State regulations. Director, D artment of Licensing -- :Z!^,�,-.�`i.�."k' y'4'. . y .3.'� . . ..� �::o =' :44 -'; -- ^`Ty ..: ' ..._'., :d "'"';, �T��s rv^n.��:vr.,,...4i3 - --7S., "�.r, `e mrr .;. `... 16.,. ., -1 a.-: + -,..— - --;.- ?4=. ...,.. :.;Y.z= ...,,.� .rr..r.-.w, ..w4.,vm .....,w...� s.....,. vm, mrx..:.m mc........ nr, xa.ca.a,m ............+n. ...... ;.;..ai.., ..�,.,....::5'i «-.�,..;. ru. ....._.: -r-a ..........,.. JC.,-. r.......: h- r a;..: �r. i. u� ........1.S.rr�rL x- .,�....rr., �3'!.i! UBI NO. 601 318 369 1 PSF MECHANICAL, INC. 500 GALLAND BLDG 1221 SECOND AVE SEATTLE WA 98101 2925 EXPIRATION 05- 31-2011 Please tear off this section and keep it with your records. Note: This is not a Washington business license. The expiration date indicates when you will need to renew your corporation, limited liability company or Massachusetts trust in Washington State. You may renew again at dol.wa.gov after November 1, 2010. Use the new password: C368 65K9. For security purposes the password changes each year after you renew. Please read the information printed on the back side of this document. For business license information go to dol.wa.gov or 360- 664-1400. SYMBOLS & ABBREVIATIONS SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION LOCATION o c.' A.C. AIR CONDITIONING UNIT A.D. AIR DOOR A.F.F. ABOVE FINISHED FLOOR m (AC -XXX) MECHANICAL EQUIPMENT TAG ELECTRICAL NOM. NOMINAL /X/X/ O.B.D. OPPOSED BLADE DAMPER 8.5 ORIFICE SIZE (INCHES) O.A. OUTSIDE AIR Ov. OVAL /// P.B.D. PARALLEL BLADE DAMPER P.O.C. POINT OF CONNECTION NOTES B.Q.D. BACKDRAFT DAMPER B.S. BIRD SCREEN B.O.G. BOTTOM OF GRILLE B.O.D. BOTTOM OF DUCT BT B.T. BYPASS TIMER 0 CARBON DIOXIDE SENSOR i CUH CENTER LINE DIA. DIAMETER • D.S. DISCONNECT SWITCH D.T.S. DUCT TEMPERATURE SENSOR -. i.v.) r‘‘, al R RB Zvi R. RELOCATE R.A. RETURN AIR R.B. REBALANCE R.A.G. RETURN AIR GRILLE R.V.Q. REMOTE VOLUME DAMPER RETURN DUCT DOWN ® RETURN DUCT UP = D.G. DOOR GRILLE • OX DRAWING NOTE rD D DUCT DROP IN DIRECTION OF ARROW E -POWER AC-4 TRANE TCD -240 SERVER ROOM ii SIDE INLET CAN R R DUCT RISE IN DIRECTION OF ARROW DN. DOWN E.C.H. ELECTRIC CEILING HEATER E.D.C. ELECTRIC DUCT COIL E.F.C. ELECTRIC FAN COIL E.U.H. ELECTRIC UNIT HEATER E.C. ELECTRICAL CONTRACTOR e ELEVATION EXIST. EXISTING E.A. EXHAUST AIR E.F. EXHAUST FAN EXT. EXTERIOR OR EXTERNAL 5 800 10.20 - 1 SD 1 - S.D. SMOKE DETECTOR . O ® YES S. DMPR. SMOKE DAMPER S.P.F. SMOKE PURGE FAN S.S.S.C. SOLID STATE SPEED CONTROL S.L. SOUND LINING _ TRANE TCD -240 SERVER ROOM SP. DMPR. SPLITTER DAMPER RECT. ROUND 1 5 SQUARE TO ROUND DUCT TRANSITION 1 - SIS START /STOP SP ( STATIC PRESSURE SENSOR S.A. SUPPLY AIR �; SUPPLY DUCT DOWN 56.2 �� eEXTR. EXTRACTOR CEILING F.I.T. FAN INDUCTION TERMINAL 0.75 al ® SUPPLY DUCT UP FD F.D FIRE DAMPER 0 © C SW. SWITCH T.C. TEMPERATURE CONTROL T.S. TEMPERATURE SENSOR TSTAT. THERMOSTAT NO BDD FSD F.S.D. FIRE /SMOKE DAMPER 1,3 F.O.B. FLAT ON BOTTOM F.O.T. FLAT ON TOP COOK / 100C15DH ):12( TOP INLET LAY -IN Jr 11110 F.C. FLEXIBLE CONNECTION G.C. GENERAL CONTRACTOR T.O.D. TOP OF DUCT T.F. TRANSFER FAN GRILLE, REGISTER, OR DIFFUSER TYPE y } T.V. TURNING VANES A 8x8 NECK SIZE (INCHES) _ 20D NO U.D. UNDERCUT DOOR V.A.V. VARIABLE AIR VOLUME TERMINAL AIR QUANTITY (CFM) GIRID I.D. NUMBER H.P. HEAT PUMP OR HORSEPOWER INT. INTERLOCK M.UA. MAKE-UP AIR M.U.F. MAKE -UP AIR FAN M.C. MECHANICAL CONTRACTOR 1 V.D. VOLUME DAMPER COOK / 100C15DH ROOF BREAK ROOM 238 DD CENTRIFUGAL ©1 WIRE GUARD COVER OVER TEMPERATURE SENSOR ICI WIRE GUARD COVER OVER THERMOSTAT 50 MD 1 1/8 M.D. MOTORIZED DAMPER NO GENERAL NOTES 1. ALL DUCTWORK SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDAN CODES, RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF THE 2006 WASHINGTON STATE ENERGY CODE, AND THE 2006 WASHINGTON STATE E WITH Ail- APPLICABLECOI KWILA, THE 2009 INTERNAT TllATIOALC1 EA e•J S AND ORDINANCES: NAL MECHANICAL CODE, 2. RECTANGULAR AND ROUND DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH SOUNDLINING OR EXTERNAL INSULATION WRAP AS INDICATED IN NOTE 4 UNLESS OTHERWISE NOTED. 3. FLEXIBLE DUCTWORK SHALL BE CLASS 1 CONFORMING TO U.L. STANDARD 181 AS REQUIRED BY LOCAL CODE OR AGREEMENT. 4. DUCTWORK SHALL BE INSULATED PER THE TABLE BELOW DUCTS REQUIRING INSULATION: A. INDOOR, CONCEALED SUPPLY AND OUTDOOR AIR. B. INDOOR, CONCEALED RETURN LOCATED IN NONCONDITIONED SPACE. C. OUTDOOR, EXPOSED SUPPLY AND RETURN. ITEMS NOT REQUIRING INSULATION: A. METAL DUCTS WITH DUCT LINER OF SUFFICIENT THICKNESS TO COMPLY WITH LOCAL ENERGY CODE. B. FACTORY - INSULATED FLEXIBLE DUCTS. C. FLEXIBLE CONNECTORS. D. VIBRATION - CONTROL DEVICES. E. FACTORY- INSULATED ACCESS PANELS AND DOORS. 5. TAPE OR SEAL ALL JOINTS IN CONCEALED DUCTWORK SYSTEM 6. ALL CUTTING, PATCHING, FRAMING, FIRE SAFING, PAINTING, ROOF OPENING CURBS, ROOFING ETC., REQUIRED TO INSTALL MECHANICAL SYSTEM HEREIN SHALL BE BY GENERAL CONTRACTOR, INCLUDING ALL FLASHING, SEALING, FRAMING AND ROOFING ON SHEET METAL DUCT ENCLOSURES. 7. MECHANICAL EQUIPMENT ACCESS PANELS IN FURRED ENCLOSURES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 8. POWER WIRING AND CONNECTIONS TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. CONTROL WIRING AND LOW VOLTAGE CONNECTION TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. 9. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SHEET METAL. 10. ALL MEDIUM PRESSURE DUCT TO BE MANUFACTURED IN ACCORDANCE WITH SMACNA MEDIUM PRESSURE STANDARDS. 11. BUTTER ALL JOINTS AT SOUNDLINING IN MEDIUM PRESSURE DUCTWORK. 12. ALL MEDIUM PRESSURE DUCT TAKEOFF FITTINGS SHALL BE BOOT TEES UNLESS OTHERWISE NOTED. 13. INLET CONNECTIONS TO ALL MEDIUM PRESSURE TERMINAL UNITS SHALL HAVE BEAD AND CRIMP TO ASSURE POSITIVE FLEXIBLE DUCT CONNECTION. MINIMUM FLEX DUCT LENGTH SHALL BE THREE FEET UNLESS RESTRICTED BY LOCAL CODE OR AGREEMENT. 14. ELEVATIONS SHOWN ON THESE DRAWINGS ARE INTENDED FOR DESIGN COORDINATION ONLY. REFER TO HVAC SHOP DRAWINGS FOR EXACT ELEVATIONS AND DIMENSIONS. 15. CONTACTORS, MAGNETIC STARTERS AND DISCONNECT SWITCHES SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 16. DRAWINGS AND MANUALS SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE 2006 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416. 17. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THE 2006 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2.3- 1416.2.6.3. 18. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2006 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2- 1416.2.3. 19. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE WIIBC, IMC & SMACNA SEISMIC STANDARDS. 20. PROVIDE PIPE INSULATION PER 14-6 WSEC. 21. PROVIDE 5 DEGREE DEADBAND WI AUTO SETBACK PER WSEC. 22. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICAL SYSTEMS PER WSEC TABLE 14.4. 23. EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT. 24. ?DUCT INSULATION IS SHOWN WHERE REQUIRED BY CODE. INSULATION OUTSIDE OF SHELL AND CORE AREAS SHALL BE PROVIDED AS ART OF THE TENANT IMPROVEMENT PROJECTS. 25. ACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 °F WITHIN WHICH THE SUPPLY OF HEATING AND :OGLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM. 26. MOTORIZED DAMPERS WILL BE PROVIDED TO CLOSE AUTOMATICALLY WHEN IT'S RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE. 27. HEATING AND COOLING SYSTEMS SHALL HAVE OPTIMUM START CONTROLS. 28. AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO 100% OF THE DESIGN SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING. 29. ALL ELECTRICAL DEVICES SHALL BE MOUNTED PER ARCH DWG. 9.3, DETAIL D. 30. ALL ROOM SENSORS TO BE LABELED TO CORRESPONDING FAN TERMINAL UNIT. SEPARATE PERMIT REQUIRED FOR Methanical Electrical Plumbing 1 Gas Piping City of Tukwila BUILDING DIVISION PACKAGED AIR CONDITIONER SCHEDULE • TAG MANUFACTURER/ MODEL # LOCATION TOT. COOLING (MBH) FAN OSA CFM EER ELECTRIC COIL ELECTRICAL WEIGHT (LBS) NOTES CFM ESP HP VOLT/ PH KW STAGES VOLT/PH MCA E -POWER AC-4 TRANE TCD -240 SERVER ROOM 240 8000 1 5 800 10.20 - - - 460/3 56.2 YES 2200 1-6 AC -5 TRANE TCD -240 SERVER ROOM 240 8000 1 5 800 10.20 - - - 46013 56.2 NO 2200 1-6 NOTES: 1. ELECTRICAL TO PROVIDE DISCONNECT. 2. WI SINGLE POINT POWER CONNECTION. 3. MCA LISTED IS TOTAL MCA . 4. FACTORY INSTALLED DOWNFLOW ECONOMIZER 5. POWERED EXHAUST 6. ONE UNIT RUNS, THE SECOND UNITS IS FOR STAND -BY. ALTERNATE WEEKLY. EXHAUST FAN SCHEDULE TAG MANUFACTURER/ MODEL # LOCATION SERVES TYPE FAN PERFORMANCE ELECTRICAL BDDI MD WEIGHT (LBS) NOTES CFM ESP • RPM SOUND (dBA) BHP HP VOLTIPH E•POWER EF-4 COOK / 100C15DH ROOF BREAK ROOM 142 DD CENTRIFUGAL 400 0.7 1545 50 121W 118 120/1 NO BDD 58 1 EF -5 COOK I GN -182 ROOM 104 TOILET ROOM 104 CEILING 120 • 1.0 1375 46 129W - 120/1 NO BDD 21 1,3 EF -6 COOK I GN -182 ROOM 268 TOILET ROOM 268 CEILING 136 0.75 1279 45 126W - 120/1 NO BDD 21 1,3 EF -7 COOK / 100C15DH ROOF BREAK ROOM 273 DD CENTRIFUGAL 400 0.7 1545 50 121W 1/8 120/1 NO BDD 58 1 EF -8 COOK / 100C15DH ROOF BREAK ROOM 238 DD CENTRIFUGAL 400 0.7 1545 50 121W 1/8 120/1 NO BDD 58 1 NOTES: 1. DISCONNECT BY ELECTRICAL CONTRACTOR. 2. MOTOR STARTER BY ELECTRICAL CONTRACTOR. 3. INTEGRAL BACKDRAFT DAMPER. 4. WALL COLLAR. 5. DAMPER. 6. MOTOR SIDE GUARD. 7. WEATHERHOOD. 8. SPRING ISOLATORS. 9. HIGH EFFICIENCY MOTORS. 10. TSTAT (MT. AT 48" AFF, SET AT 80° F REVISIONS No changes shall be made to the scope of workw,ihout prior approval of Tukwila Building Division. NOTE Revisions will require a new plan submitzt t and may include additional plan review fees. 1 DIFFUSER/GRILLE SCHEDULE SYMBOL MANUFACTURER 1 MODEL # SIZE TYPE NOTES A SHOEMAKER 700MA AS NOTED LAY -IN MODULAR CORE DIFFUSER C 0 R R E C LTA #�� B SHOEMAKER 933 AS NOTED SURF. MNT DOUBLE DEFL. DIFFUSER M -103 C SHOEMAKER 600T AS NOTED LAY -IN EGGCRATE RET/EXH GRILLE D SHOEMAKER 600 AS NOTED SURF. MNT EGGCRATE RET/EXH GRILLE E SHOEMAKER MA AS NOTED SURF. MNT MODULAR CORE DIFFUSER REVIEVvED FOR CODE COMPLIANCE APPROVED SEP 21.2010 Cityof -Wla BUILDING DIVISION VICINITY MAP SITE PLAN Parker nelneciid LEGAL DESCRIPTION PARCEL NUMBER: 3523049121 LEGAL DESCRIPTION LOTS 3 & 4 OF CITY OF TUKWILA SHORT PLAT NO 86-45 SS RECORDING NO 8609081152 AS AMENDED BY CITY OF TUKWILA LOT LINE ADJ NO 93 -0085 RECORDING NO 9311301961 AS LOT 4 DAF - PORTION OF SW 1/4 OF NE 1/4 AND OF GOV LOT 2 & 5 - BEGIN NE CORNER OF SW 1/4 OF 114TH S 07 -44 -56 W 346.40 FT THS 82 -15 -04 E 30 FT TO POB TH N 75 -05-56 E 75.10 FT TH ALONG CURVE TO LEFT RADIUS OF 409.26 FT THRU CIA OF 58 -14 -17 ARC DISTANCE OF 415.99 FT TAP OF COMPOUND CURVE TH ALONG CURVE TO LEFT RADIUS OF 572.96 FT THRU C/A OF 00 -25-39 ARC DISTANCE OF 4.28 FT TAP ON S MGN OF S 180TH ST TH NELY ALONG SAID S MGN ON CURVE TO LEFT CENTER BEARING N 03 -56 -50 W RADIUS OF 336 FT THRU C/A OF 16 -23 -31 ARC DISTANCE OF 96.13 FT TH S 36 -31 -53 W 135.86 FT TH ALONG CURVE TO LEFT RADIUS OF 430 FT THRU C/A OF 14 -28-22 ARC DISTANCE OF 108.63 FEET TH S 22 -03 -26 W 34.28 FT TH ALONG CURVE TO LEFT RADIUS OF 800 FT THRU C/A OF 1844-11 ARC DISTANCE OF 261.61 FT TH S 03 -19 -15 W 141.75 FT TH ALONG CURVE TO LEFT RADIUS OF 3500 FT THRU C/A OF 03 -41 -20 ARC DISTANCE OF 225.34 FT TH S 07 -00 -35 W 20.08 FT TH S 09 -03 -25 W 579.24 FT TH S 06 -4445 W 82.23 FT TH N 66 -54 -09 W 338.39 FT TH IN NLY DIRECTION ALONG CURVE TO LEFT CENTER BEARING N 71 -16 -17 W RADIUS OF 2530 FT THRU C/A OF 10 -5847 ARC DISTANCE OF 484.83 FT TH N 07 -44 -56 E 610.27 FT TO POB - -- LOT 4 OF CITY OF TUKWILA LOT LINE ADJ NO 93 -0085 RECORDING NO 9311301961 -- LESS RR RAN ESMT IN NE 1/4 & SE 1/4 (OPERATING PROPERTY) FE LE ? PY permit No.. M‘,0- -gyp Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize t' + violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions) acknowledged: By City Of Tukwila BUILDING DIVISION 114 k r e ,, Y I "ii fin WI mg €1n RECEIVED CITY OF TUKWILA nfn_i 4 2010 ENTER DRAWING SCHEDULE DWG. DESCRIPTION PERMIT M -001 HVAC GENERAL NOTES, LEGENDS, AND SCHEDULES 5 M -002 HVAC SCHEDULES FIRST FLOOR HVAC PLAN C 0 R R E C LTA #�� M -101 M -102 SECOND FLOOR HVAC PLAN M -103 ROOF HVAC PLAN 1 r) t w a 0 o. z z 0 w c TY OF TUKWILA REVISIONS w 0 0 z rn 0 c%) L= (1)1- -Jo z G � WI zz W W Z 0 I-- z Q U = V) W J 0 W U (1) can0 z 0 z �W V W J 18100 ANDOVER PARK WEST TUKWILA, WA 98138 ISSUE DATE: 09/10/10 JOB. No. 1922 DWG. PURPOSE: CD SET M -001 SHT. 1 OF 5 ■ - FAN POWERED TERMINAL UNIT WITH ELECTRIC COIL SCHEDULE JOB. No. 1922 TAG MANUFACTURER/ MODEL # UNIT SIZE SERVES ROOM # 5 PRIMARY AIR VALVE FAN ELECTRIC HEATING COIL ELECTRICAL CONNECTION WEIGHT (LBS) NOTES AC SYSTEM INLET (IN) MAX CFM MIN CFM CFM ESP HP SPD KW VOLT/ PH STEPS EAT LAT MOTOR VOLTIPH MOTOR FLA MCA E•POWER FTU -101 TRANE /VSEF 0502SQ 126 AC -2 5 320 120 370 0.3 1/8 PSC 4.5 480/3 1 64.2 93.9 277/1 0.7 7.6 N 78 1,2 B=TU -102 TRANE / VSEF 1003SQ 127,128 AC -2 10 935 165 1075 0.3 113 ECM 9.5 480/3 2 67.2 89.2 27711 2.4 17.4 N 85 1,2 FTU -103 TRANE /VSEF 0803SQ 136,137,139 AC -2 8 690 105 795 0.3 1/3 ECM 7.0 480/3 2 67.6 89.4 277/1 2.4 13.6 N 85 1,2 TU -104 TRANE / VSEF 1205S0 140,141,144 AC-1 12 1410 660 1620 0.3 1 ECM 19.0 480/3 2 62.7 91.8 27711 5.4 35.4 N 100 1,2,4 FTU -105 TRANE/VSEF 0803SQ 151,152,153,154 AC-1 8 680 105 780 0.3 1/3 ECM 7.0 480/3 2 67.6 89.8 277/1 2.4 13.6 N 85 1,2 FTU -106 TRANE /VSEF 0803SQ 155,156,157 AC-1 8 590 105 680 0.3 1/3 ECM 6.5 480/3 2 67.2 90.4 27711 2.4 12.8 N 85 1,2 FTU -107 TRANE/VSEF 0803SQ 158 AC -1 8 625 282 720 0.3 1/3 ECM 8.0 480/3 1 63.0 91.3 277/1 2.4 15 N 85 1,2 FTU -108 TRANE /VSEF 1206SQ 159,160,166,167,168,169,172 AC-1 12 1570 240 1805 0.3 1 ECM 16.5 480/3 2 67.6 90.3 277/1 5.1 31.2 N 117 1,2,4 FTU -109 TRANE /VSEF 0803SQ 173 AC-1 8 600 105 690 0.3 1/3 ECM 6.5 480/3 2 67.3 90.1 27711 2.4 12.8 N 85 1,2 FT1J-110 TRANE /VSEF 1004S0 174,176,177,178,180 AC-1 10 1105 165 1270 0,3 112 ECM 11.5 480/3 3 67.7 90.0 277/1 3.5 21.6 N 86 1,2 FTU -111 TRANE /VSEF 1003SQ 181,186,187,188 AC-1 10 915 165 1050 0.3 1/3 ECM 9.5 48013 2 67.2 89.6 27711 2.4 17.4 N 85 1,2 FU-112 TRANE /VSEF 1004SQ 100,103,104,191 AC -2 10 960 165 1105 0.3 112 ECM 10.0 48013 3 67.3 90.1 27711 3.5 19.4 N 86 1,2 FTU -113 TRANE / VSEF 0602SQ 105 AC -2 6 385 120 445 0.3 118 PSC 4.5 480/3 1 65.1 89.9 277/1 0.7 7.6 N 78 • 1,2 FTU -914 TRANE /VSEF 1004SQ 108,109, 110,111 AC -2 10 1010 165 1160 0.3 . 1/2 ECM 10.0 480/3 1 67.4 89.1 277/1 3.5 19.4 N 86 1,2 FTU -115 TRANE /VSEF 08035Q 113,114,115,116 AC -2 8 835 105 960 0.3 1/3 ECM 8.0 480/3 1 68.0 89.3 27711 2.4 15 N 85 1,2 FTU -116 TRANE I VSEF 0502SQ 117 AC -2 5 290 40 335 0.3 118 PSC 3.0 480/3 1 67.9 91.3 27711 0.7 5.4 N 78 1,2 FTU -117 TRANE/VSEF 0803SQ 118,119,122,125 AC -2 8 780 216 895 0.3 1/3 ECM 11.5 48013 1 65.7 97.3 277/1 2.4 20.4 N 85 1,2 FTU -118 TRANE /VSEF 0803SQ 128,129,131,138 AC -2 8 520 294 795 0.3 1/3 ECM 9.0 480/3 2 63.3 91.0 27711 2.4 16.6 N 85 1,2 FTU -119 TRANE /VSEF 0803SQ 142,143 AC -2 8 805 105 925 0.3 1/3 ECM 8.0 480/3 1 68.0 90.1 277/1 2.4 15 N 85 1,2 FTU -120 TRANE / VSEF 10045Q 144 AC -2 10 1010 165 1160 0.3 112 ECM 10.0 480/3 3 67.4 89.1 27711 3.5 19.4 N 86 1,2,3 FTU -121 TRANE / VSEF 0804SQ 148,161 AC-1 8 815 340 1250 0.3 1/2 ECM 12.5 480/3 2 65.1 90.3 277/1 3.5 23.2 N 86 1,2 FTU -122 TRANE / VSEF 0602SQ 165 AC-1 6 460 60 460 0.3 118 PSC 4.0 480/3 1 67.7 88.2 27711 0.7 6.8 N . 78 1,2,3 FTU -123 TRANE /VSEF 0502SQ 171 AC-1 5 230 AO 265 0.3 1/8 PSC 2.5 480/3 1 67.3 91.0 27711 0.7 4.6 N 78 1,2,3 FTU -124 TRANE / VSEF 0803SQ 175,179,182,185 AC-1 8 525 229 805 0.3 1/3 ECM 8.0 480/3 1 64.9 90.3 27711 2.4 15 N 85 1,2 FTU -125 TRANE /VSEF 0803SQ 101,146,147,183,184,190 AC-1 8 530 274 815 0.3 1/3 ECM 9.0 480/3 2 63.9 91.0 277/1 2.4 16.6 N 85 1,2 FTU -126 TRANE / VSEF 0502SQ 102 AC -2 5 230 40 265 0.3 118 PSC 2.5 480/3 1 67.3 91.0 277/1 0.7 4.6 N 78 1,2,3 FTU -127 TRANE / VSEF 0402SQ 112 AC -2 4 145 25 145 0.3 1/8 PSC 1.5 480/3 1 66.9 88.6 277/1 0.7 3.2 N 78 1,2,3 FTU -128 TRANE /VSEF 10048Q 106,107,118,120,123,131,133 AC -2 10 975 391 1120 0.3 112 ECM 12.5 480/3 3 63.7 91.8 277/1 3.5 23.2 N 86 1,2 FTU -129 TRANE / VSEF 0402SQ 124 AC -2 • 4 140 25 140 0.3 1/8 PSC 1.5 48013 1 66.8 89.3 27711 0.7 3.2 N 78 1,2,3 FTU -130 TRANE /VSEF 0802SQ 130 AC -2 8 550 105 635 0.3 118 PSC 5.5 480/3 1 67.0 89.3 27711 0.7 9.2 N 78 1,2,3 FTU -131 TRANE / VSEF 0502SQ 134 AC -2 5 305 160 350 0.3 118 PSC 4.0 480/3 1 61.8 88.7 277/1 0.7 6.8 N 78 1,2 FTU -132 TRANE /VSEF 0502SQ 135 AC -2 5 225 40 260 . 0.3 1/8 PSC 2.5 48013 1 67.2 91.4 277/1 0.7 4.6 N 78 1,2 FTU -133 TRANE /VSEF 0602SQ 149,150,162,163 AC-1 6 365 185 420 0.3 1/8 PSC 5.0 480/3 1 62.1 92.0 277/1 0.7 8.4 N 78 1,2 FTU -201 TRANE 1 VSEF 0602SQ 228 AC -2 6 450 60 520 0.3 118 PSC 5.0 480/3 1 67.9 92.1 27711 • 0.7 8.4 . N 78 1,2 FTU -202 TRANE /VSEF 1004SQ 229,230,231,232,241 AC -2 10 1035 165 1190 0.3 1/2 ECM 11.5 480/3 3 67.5 91.3 27711 3.5 21.6 N 86 1,2 FTU -203 TRANE /VSEF 100550 242,243,245,246,247 AC -2 10 1035 165 1190 0.3 1 ECM 11,5 480/3 3 67.5 - 91.3 277/1 5.4 24 N 100 1,2,4 FTU -204 TRANE / VSEF 1004SQ 251,252,253,255,256 AC -2 10 950 320 1095 0.3 1/2 ECM 11.5 480/3 3 64.7 90.6 27711 3.5 21.6 N 86 1,2,4 FTU -205 TRANE /VSEF 1003SQ 257,259,260,261,267 AC-1 10 950 165 1095 0.3 113 ECM 9.5 480/3 2 67.3 88.8 277/1 2.4 17.4 N 85 1,2 FTU -206 TRANE / VSEF 1004SQ 268,268F,R AC-1 10 1065 300 1225 0.3 1/2 ECM 12.5 48(.!3 3 65.6 91.3 27711 3.5 23.2 N 86 1,2 FTU -207 TRANE / VSEF 0602SQ 270,27, AC-1 6 450 61 520 0.3 118 PSC 4.5 48, /3 2 67.9 89.1 277/1 0.7 7.6 N 78 1,2 FTU -208 TRANE /VSEF 0803SQ 271 AC-1 8 880 320 1010 0.3 1/3 ECM 11,5 4a .3 1 64.3 92.3 27711 2.4 20.4 N 85 1,2 FTU -209 TRANE / VSEF 0803SQ 275 AC -1 8 890 105 1025 0.3 113 ECM 9.0 48L1 2 68.2 89.6 277/1 2.4 16.6 N 85 1,2 FTU -210 TRANE / VSEF 1004SQ 277,278,283,284 AC-1 10 1100 165 1265 0.3 112 ECM 10.5 480/3 3 67.7 88.8 277/1 3.5 20.2 N 86 1,2 FTU -211 TRANE / VSEF 0803SQ 285,286 AC-1 8 825 105 950 0.3 1/3 ECM 8.0 48013 1 68.0 89.5 27711 2.4 15 N 85 1,2 FTU -212 TRANE / VSEF 0502SQ 287 AC -1 5 275 120 315 0.3 118 PSC 3.0 480/3 1 63.1 88.1 27711 0.7 5.4 N 78 1,2 FTU -213 TRANE / VSEF 0602SQ 289 AC -2 6 370 60 425 0.3 1/8 PSC 4.0 48013 1 67.5 89.7 27711 0.7 6.8 N 78 1,2,3 FTU -214 TRANE / VSEF 1005S0 206,207,208,210,211 AC -2 10 1145 165 1315 0.3 1 ECM 11.5 480/3 3 67.7 89.3 277/1 5.4 24 N 100 1.2,4 FTU -215 TRANE I VSEF 1005S0 212,213,214,215,216 AC -2 10 1130 165 1300 0.3 1 ECM 11.5 480/3 3 67.7 89.5 277/1 5.4 24 N 100 1,2,4 FTU -216 TRANE / VSEF 0802SQ 217 AC -2 8 510 105 585 0.3 1/8 PSC 5.5 480/3 1 66.8 91.0 277/1 0.7 9.2 N 78 1,2 FTU -217 TRANE/VSEF 0803SQ 222,223,224,226,227 AC -2 8 640 105 735 0.3 1/3 ECM 9.0 480/3 2 67.4 97.4 277/1 2.4 16.6 N 85 1,2 FTU -218 TRANE / VSEF 0602SQ 225,233,234,235 AC -2 6 365 152 560 0.3 1/8 PSC 5.5 480/3 1 65.1 90.4 277/1 0.7 9.2 N 78 1,2 FTU -219 TRANE / VSEF 0502SQ 233,240,244 AC -2 5 265 109 405 0.3 118 PSC 4.0 48013 1 65.2 88.5 27711 0.7 6.8 N 78 1,2 FTU -220 TRANE / VSEF 0602SQ 239 AC -2 6 430 240 495 0.3 1/8 PSC 5.5 480/3 1 61.3 89.9 27711 0.7 9.2 N 78 1,2 FTU -221 TRANE/VSEF 0803SQ 248,249,250,254,288 AC-1 8 650 291 995 0.3 113 ECM 10.0 480/3 3 64.7 90.0 277/1 2.4 18 N 85 1,2 FTU -222 TRANE / VSEF 0804SQ 258,262,265,266 AC-1 8 735 260 1125 0.3 1/2 ECM 11.5 480/3 1 65.8 91.0 277/1 3.5 21.6 N 86 1,2 FTU -223 TRANE / VSEF 0602SQ 269,272,273,276 AC-1 6 • • • 445 148 510 0.3 118 PSC 5.0 480/3 1 64.8 89.4 277/1 0.7 8.4 N 78 1,2 FTU -224 TRANE /VSEF 0602SQ 264,279 AC-1 6 425 166 650 0.3 1/8 PSC 6.5 48013 2 65.4 89.6 277/1 0.7 10.6 N 78 1,2 FTU -225 TRANE / VSEF 0803SQ 281,282 AC-1 8 720 260 1105 0.3 1/3 ECM 11,5 48013 1 65.8 91.4 277/1 2.4 20.4 N 85 1,2 FTU -226 • TRANE I VSEF 0502SQ 200,201,202,203,205,244 AC -2 5 290 123 445 0.3 • 1/8 PSC 4.5 48013 1 65.0 89.8 277/1 0.7 7.6 N • 78 1,2 FTU -227 TRANE / VSEF 1004SQ 204 AC -2 10 1295 165 1295 0.3 1/2 ECM 11.5 480/3 1 67.7 89.6 277/1 3.5 21.6 N 86 1,2,3 FTU -228 TRANE / VSEF 0803SQ 218,220,237 AC -2 8 570 190 875 0.3 1/3 ECM 8.0 480/3 1 66.1 89.5 277/1 2.4 15 N 85 1,2 FTU -229 TRANE / VSEF 0603SQ 218,221,225 . AC -2 6 430 176 660 0.3 1/3 ECM 6.5 480/3 • 2 65.2 89.0 277/1 2.4 12.8 N 85 1,2 FTU -230 TRANE /VSEF 0602SQ 236 AC -2 6 490 60 490 0.3 1/8 PSC 4.5 48013 1 67.8 90.3 27711 0.7 7.6 N 78 1,2,3 FTU -231 TRANE/VSEF 0502SQ 219 AC -2 5 230 40 265 0.3 1/8 PSC 2.5 480/3 1 67.3 91.0 27711 0.7 4.6 N 78 1,2,3 FTU -232 TRANE / VSEF 0803SQ 238 AC -2 8 600 360 690 0.3 1/3 ECM 8.0 480/3 1 60.6 90.2 277/1 2.4 15 N 85 1,2 FTU -233 TRANE / VSEF 0502SQ 263 AC-1 5 230 40 265 0.3 118 PSC 2.5 480/3 1 67.3 91.0 27711 0.7 4.6 N 78 1,2,3 FTU -234 TRANE / VSEF 0502SQ 280 AC-1 5 230 40 265 0.3 118 PSC 2.5 48013 1 67.3 91.0 277/1 0.7 4.6 N 78 1,2,3 NOTES: 1. DISCONNECT BY ELECTRICAL. 2. SERIES FAN POWERED TERMINAL UNIT WITH HEAT -, SIZE AS LISTED, PRESSURE INDEPENDENT, FACTORY OPTIONS INCLUDE: - EXTENDED DAMPER 1/2" DIAM. SHAFT - FACTORY INSTALLED 1" THROW -AWAY FILTERS - CONTROLS BY OTHERS - 1" MATT -FACED UNIT INSULATION - VARIABLE SPEED FAN CONTROL - 24V TRANSFORMER, 50 VA MIN RATING - HEAT STAGING & FAN CONTROL THROUGH FACTORY WIRED RELAYS - AUTO RESET 130 °F HIGH LIMIT TSTAT - NON MAGNETIC QUIET ACTING HEATER CONTACTOR NOTE TO ELECTRICAL: - 460V /3PH TERMINAL UNITS REQUIRE A FOUR WIRE POWER FEED IN ORDER TO SUPPLY 277V/1 PH POWER TO THE FAN MOTOR. 3. CO2 SENSOR VENTILATION CONTROL SCHEME REQUIRED. INDIVIDUAL ZONE CO2 SENSOR TO OVERRIDE MINIMUM PRIMARY AIR REVIEWED FOR CODE COMPLIANCE APPROVED SEP 21 2010 City of Tukwila BUILDING DIVISION 14110-Id( REV. NO. /DATE z 0 w 0 0 z CITY OF TUKWILA REVISIONS RECEIVED CITY OF TUKWILA SEP 14, 2010 PERMIT CENTER I- U) J < I- LL! Z w Z U) I--- O Z Q 0> U 18100 ANDOVER PARK WEST TUKWILA, WA 98138 'ISSUE DATE: 9/13/10 JOB. No. 1922 DWG. PURPOSE: CD SET M -002 SHT. 2 OF 5 • ..17.,12=•31117{SMEMitilIMM.> b 1 0 )I 1 • j» f` £ REVIEWED FOR CODE COMPLIANCE APPROVED SEP 21 2010 City of Tukwila BUILDING DIVISION ("c 220 =295 W iF Nto *TO �4el•welelelll fall 10x10 300 AXE' w t�. 4a <.:., . ; , 10x10 Q Q ® 295 W el .-., Et . L - e y leIolimmi■ 2&c 1 1 1 € €i • 16'0 ...:- <<,En, As/ 8 •10x10 260 67°x1911- U TO AC-4 0000. .0 0-00, INTO ithdo ,:Ett `1c181 • E: Eft I x10 10*1 -a r0X10 10x10 325 IBM rit•° rf, r � .Ez'.sia 16 "0 4, 'Vt.- €{: Ro 0 8x8 so f'K 10 :138 214. ........ f . • 300 ... • 8x8 210 Mir 40, 15 ' 4 d� r b„:,10,(10 309 W Q 10x10 Q F 325 Mr 40 � 1 »t . e II�I� r € ;' 10x10 Q 345 w • • . •.: %"f " >. • f • GENERAL NOTES: SECOND FLOOR HVAC PLAN SCALE : 1/8" = 1' -0" £ 1. ALL TEMPERATURE SENSORS SHALL BE MOUNTED PER ARCH DWG 9.3D. 2. ALL ROOM SENSORS TO BE LABELED TO CORRESPONDING VAV BOX. DRAWING NOTES; O Q 24x24 RA 24x24 RA W/ 90' 1' SL BOOT 24x12 RA W/ 90 1' SL BOOT O5 OVERSIZE FLOOR PENETRATION FOR DUCT ONLY ENOUGH TO ALLOW PASSAGE OF DUCT. FLOOR PENETRATION AROUND DUCT MUST BE PROTECTED WITH APPROVED NON - COMBUSTIBLE MATERIAL © CONTROL DAMPERS REQUIRED FOR AC UNIT SWITCHOVER. ONE AC UNIT RUNS, THE OTHER IS STANDBY. ALTERNATE UNITS WEEKLY. 7O SMOKE DETECTOR LOCATED IN RETURN NR PLENUM DUCT. INCLUDED AS PART OF SHELL AND CORE PERMIT. t RECEIVED CITY OF TUKWILA SEP 14 2010 PERMIT CENTER r I, w 0 0 z z w 0 0 z Z J H <\ —I = J0 <0 Z t..L in Z z �0 Z O Ow O u) 18100 ANDOVER PARK WEST TUKWILA, WA 98138 ISSUE DATE: 9/13/10 • JOB. No. 1922 DWG. PURPOSE: CD SET M -102 SHT. 4 OF 5 • _.4 1 1 1 1 r" ;I 3 ^4 ,t ,-3•-• 3 3. 3 € 7. \ ; • I, 3-1 1 SMOKE DETECTOR LOCATED IN RETURN OF-AC-UNIP.- INCLUDED -AS -PART- -- OkHELL-AND CORE-PERM1T. •.-;kt," (AC-4) (EF-4) 3 3 3 > i 3 i 1. 3 3 3 3 ; €. s. i r- 3 3 3 r) 3 AMMICIMMM /1 3. N N N N FOR AC-4 AND AC-5, SEE SOLE 2 STORY 13e21111.21:616111CIL r -4 F' A • 3 5. }Car W/LONSENEC B.S. & B.D.D. OrF10E BUILDING SHELL AND CORE A2.3 FOR CREENING AND S1.3 FOR SIR' CTURAL SHE1L AND CORE MECHANICAL bOES NOT SHOW -- EQUIPMENT. i 0 N N 43,4".3 S :S34:: 3M. 4 343:::s4 -.3.-33333.434 % € -------1 % 3 11. ........ .............. .. , SMOKE DEFECTOR LOCATED 14ETURN ; AIR OF AC-UNIT. INCLUDED A PART OF SHELL AND CORE PERMIT. I I € 7,7 1:...0%&333334,k3a44 90343M 44433443zAa' 4'444: • 43'334333:33 .33334344.333333M3.433.33 44, ss, 3s4.434 SW€: sual1€1€ QR AC-4 AND AC-5, SEE SE4ALE 2 STORY ‘- -FiCE BUILDING SHELL AND CORE A2.3 FOR REENING AND S1.3 FOR STRUCTURAL ELL AND CORE MECHANICAL DOES NOT SHOW EQUIPMENT. 33'1..a3S,43:4 <333' 5% 44V-0.44 43434:4344:4" 3'4443 4 44. 444444'4"S 0 (AC-5) (EF-8) 334..433.33 M g 4 4 4444 '34,3 43444. 44 4 444 3,44 4.3%44 44: S4:43 413 .333444'44333333-31.&...' 43354 "3" 3 4 3-, 3 0 1 () \ 0 Erx8" DN-\ j8x8" W/ GOOSENECK, B.S. & 3 5' 5. .433 4333•" ,,„3" /3"-- I — L4 3 J5 ROOF HVAC PAN SCALE : 1/8" = 1 '-0" ..3 0 ; • , .,,..........,..A„, ,.. , , , ' t „ , „.,-, , .,-( s'",,,, MAXSICINISIEMMIZIMLL2Mik — € 3 ' REVIEWED FOR ODE COMPLIANCE APPROVED SEP 2 1 2010 City of Tukwila BUILDING DIVISION 1 3 ; 3.. C AC UNIT NAILING STRIP FASTENER (PSF) FACTORY CURB (PSF) 3/16"N TYPICAL EMBED PLATE WITH NELSON STUDS (BY OTHERS) ROOF EQUIPMENT LEVEUNG CURB 6” WIDE CONCRETE (BY OTHERS) FASTENER (PSF) 16GA. HOLD DOWN STRAP (PSF) \N\N C.:\'‘4, 4 4 A• • . • 14" A 3/16" CURB DETAIL FOR TRANE VOYAGER AC UNITS DETAIL NTS \--DUCT DROP RECEIVED CITY OF TUKWILA SEP 1 4 2010 PERMIT CENTER • CITY OF TUKWILA REVISIONS <1 STAMP: --.1 PSF Mechanical, Inc. SoERasl "Trusted to be the Better Choice" @4$ °� if4p c „ ,Ai ,...1,:...,..i' IppoF 9322 14th Avenue South _-, Seattle, WA 98108 -5102 206.764.9663 I5 ri S8 00 .767.97 6 3 I 0 NAL 1� psfmechanical.com , (i) z 0_ Z < Z F—U 0 00 oD 18100 ANDOVER PARK WEST TUKWILA, WA 98138 ISSUE DATE: 9/14/10 JOB. No. 1922 DWG. PURPOSE: CD SET M-103 SHT. 5 OF 5 o ■ N N is \Local \Segale Busi NDY STABNOV 0 PIPING & PLUMBIN6 LINE STYLES SYMBOL ABBREVIATION SW-4 SW -3 /- HWR HWS CHWR CHWS CWR CWS RS RL CW HW V 0 A D N20 G ORL RWL RWL - CD DSP FDC FP IRR DI CDI RO SS SW-4 SW -3 NPCW HWR HWS CHWS CHWS CWR CWS RS RL. HWC CW HW V W W VAC OXY. A D N20 G ORL RWC RWC ST CD DSP FDC FP IRR SS DI CDI RO SANITARY WASTE IN 4TH FLR CEILING SANITARY WATE IN 3RD FLR CEILING DEMO PIPE COLD WATER - NON POTABLE HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSING WATER RETURN CONDENSING WATER SUPPLY LIQUID SUCTION LINE LIQUID REFRIGERANT LINE HOT WATER RECIRCULATING COLD WATER HOT WATER VENT PIPE WASTE ABOVE GROUND WASTE BELOW GROUND COMPRESSED VACUUM PIPE COMPRESSED OXYGEN PIPE COMPRESSED AIR PIPE DRAIN (INDIRECT) PIPE NITROUS OXIDE NATURAL GASE PIPE OVERFLOR RAIN LEADER RAINWATER LEADER ABOVE GRADE RAINWATER LEADER BELOW GRADE STEAM PIPE CONDENSATE DRAIN PIPE DRY SPRINKLER STAND PIPE FIRE DEPT. CONNECTION PIPE FIRE PROTECTION WATER PIPE IRRIGATION WATER PIPE SANITARY SEWER PIPE DE- IONIZED WATER RECIRCULATING DE- IONIZED WATER REVERSE OSMOSIS WATER PLUMBING FIXTURE SCHEDULE MARK FIXTURE PIPING SYMBOLS & ABBREVIATIONS MFGIMODEL W SYMBOL HW ABBREVIATION CALLOUT SYMBOL WATER CLOSET ABBREVIATION CALLOUT 4" 2" AC MV AFF HCAAV MAV AG BFG BFV BV BLCV ABLCV BW BWWS CD CKV CO FD RD OFD DPS DCKV I RPBV DOF FF FCB FCR FCO FS FU GCKV GV GLV HB HR DV AIR COMPRESSOR AIR VENT - AUTO ABOVE FINISHED FLOOR AIR VENT - AUTO (HIGH CAPACITY) MANUAL AIR VENT ALIGNMENT GUIDE BELOW FINISHED GRADE BUTTERFLY VALVE BALL VALVE BALANCING VALVE BALANCING VALVE (AUTOMATIC) BULB WELL BULB WELL WITH SENSOR CANOPY DRAIN CHECK VALVE CLEANOUT DECK; PLANTER OR FLOOR DRAIN DRAIN - FLOOR DRAIN - ROOF DRAIN - ROOF OVERFLOW DIFFERENTIAL PRESSURE SWITCH DOUBLE CHECK VALVE ASSEMBLY I REDUCED PRESSURE BACKFLOW PREVENTER DIRECTION OF FLOW FLANGE FITTING FLEX CONNECTOR (BRAIDED) FLEX CONNECTION (RUBBER) FLOOR CLEANOUT FLOW SWITCH FUNNEL GAS CHECK VALVE GATE VALVE GLOBE VALVE HOSE BIBB HOSE REEL HOSE END DRAIN VALVE T IVT P -2 PT PA PC PPD PV PTRV P PSD PG DPG _ PRV RV RPBP CR ER RD SA SLV SQ. FT. STR TH THWT 3WCV TPV TDV 2WCV UN VTR VFM WCO WH PETE'S PLUG PIPE ANCHOR PIPE CAP PIPES DOWN PIPES UP PIPE PITCHED DOWN IN DIRECTION OF ARROW PLUG VALVE PRESSURE TEMPERATURE RELIEF VALVE PUMP PUMP SUCTION DIFFUSER PRESSURE GAUGE " PRESSURE GAUGE (DOUBLE) PRESSURE REDUCING VALVE PRESSURE RELIEF VALVE REDUCED PRESSURE BACKFLOW PREVENTER REDUCER - CONCENTRIC REDUCER - ECCENTRIC ROOF DRAIN SHOCK ARRESTOR SOLENOID VALVE SQUARE FEET STRAINER THERMOMETER THERMOMETER WITH TRANSMITTER THREE -WAY CONTROL VALVE TRAP PRIMER VALVE TRIPLE DUTY VALVE TWO -WAY CONTROL VALVE UNION VENTTHRU ROOF VENTURI FLOWMETER WALL CLEAN OUT WALL HYDRANT TOILET: KOHLER K- 4330 -L SEAT: BEMIS #1955C ELONGATED. FLUSH VALVE: SLOAN WES -111 4" 2" - X SEAT MUST BE 17" HIGH MINIMUM, 19" HIGH MAXIMUM - ELONGATED BOWL, SEAT - BONE, DUAL FLUSH VALVE P -3 KITCHEN SINK COUNTER y ICI I D 1/2" 1/2" FOR ALL P3 SINKS INCLUDE 750 WATT INSTA HOT WITH DUAL LEVER DISPENSER FOR HOT AND FILTERED WATER RESPECTIVELY. 101 10 COUNTER MOEN 22127 16X14 20 GA 301 SS MOEN CA8278 BAR FAUCET 2" 2" 1/2" ❑J 208 P -5 . T WALL CIF- {� I t 2" 112" ® VITREOUS CHINA WITH OVERFLOW, WHITE, WITH HANGER, SENSOR ACTIVATED FAUCET WIGRID STRAINER. PSD --�' FLOOR BY OTHERS I - Q -� PROVIDE TAILPIECE DISHWASHER CONNECTION FOR WASTE. 0 ICE MAKER FLOOR BY OTHERS p - - N RUN DRAIN TO INDIRECT WASTE FLOOR SINK OR HUB DRAIN. P -8 SHOWER FLOOR AMERICAN REINFORCED PLASTICS 36" STALL S -3637 WITH T2152 MOEN FAUCET AND SHOWER HEAD. GLASS SHOWER DOOR BY OTHERS. 2" I RPBPI 1/2" GLASS. SHOWER DOOR BY OTHERS. P -9 WALL HYDRANT EXTERIOR WALL ■ - 0 -I/4 S ❑A I 3/4" VACUUM BREAKER/FREEZELESSIFOR TILT UP CONSTRUCTION. ;Q © Di RI PENTEK DUAL CARTRIDGE FILTER HOUSING W /10 MICRON PRE - FILTER AND 5 MICRON CARBON FILTER - - I - D4 -R}-� DP -D4 FLOOR SINK FLOOR {- 2" 2" nT 4' PROVIDE TRAP PRIMER P12 g FLOOR ZURN Z- 41 -P112 W/TYPE B NICKEL BRONZE ROUND STRAINER I 2" - PROVIDE TRAP PRIMER '1_:::! 0 I I 1,7 FCO TDV TDV FS sr III I .., /WH D4 I I- r C.<111 PIPING & PLUMBIN6 LINE STYLES SYMBOL ABBREVIATION SW-4 SW -3 /- HWR HWS CHWR CHWS CWR CWS RS RL CW HW V 0 A D N20 G ORL RWL RWL - CD DSP FDC FP IRR DI CDI RO SS SW-4 SW -3 NPCW HWR HWS CHWS CHWS CWR CWS RS RL. HWC CW HW V W W VAC OXY. A D N20 G ORL RWC RWC ST CD DSP FDC FP IRR SS DI CDI RO SANITARY WASTE IN 4TH FLR CEILING SANITARY WATE IN 3RD FLR CEILING DEMO PIPE COLD WATER - NON POTABLE HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSING WATER RETURN CONDENSING WATER SUPPLY LIQUID SUCTION LINE LIQUID REFRIGERANT LINE HOT WATER RECIRCULATING COLD WATER HOT WATER VENT PIPE WASTE ABOVE GROUND WASTE BELOW GROUND COMPRESSED VACUUM PIPE COMPRESSED OXYGEN PIPE COMPRESSED AIR PIPE DRAIN (INDIRECT) PIPE NITROUS OXIDE NATURAL GASE PIPE OVERFLOR RAIN LEADER RAINWATER LEADER ABOVE GRADE RAINWATER LEADER BELOW GRADE STEAM PIPE CONDENSATE DRAIN PIPE DRY SPRINKLER STAND PIPE FIRE DEPT. CONNECTION PIPE FIRE PROTECTION WATER PIPE IRRIGATION WATER PIPE SANITARY SEWER PIPE DE- IONIZED WATER RECIRCULATING DE- IONIZED WATER REVERSE OSMOSIS WATER PLUMBING FIXTURE SCHEDULE MARK FIXTURE MOUNTING MFGIMODEL W V HW CW REMARKS P -1 WATER CLOSET FLOOR TOILET: KOHLER K- 3422 -0 SEAT: BEMIS #1955C 4" 2" - 1" SEAT MUST BE 15" HIGH MINIMUM, - ELONGATED BOWL, DUAL FLUSH VALVE P -2 WATER CLOSET ADA COMPLIANT WALL TOILET: KOHLER K- 4330 -L SEAT: BEMIS #1955C ELONGATED. FLUSH VALVE: SLOAN WES -111 4" 2" - 1.. SEAT MUST BE 17" HIGH MINIMUM, 19" HIGH MAXIMUM - ELONGATED BOWL, SEAT - BONE, DUAL FLUSH VALVE P -3 KITCHEN SINK COUNTER MOEN 21X16X8 18 GA. SINK GA 301 SS MOEN CA8701 SINGLE MOUNT FAUCET 2" 2" 1/2" 1/2" FOR ALL P3 SINKS INCLUDE 750 WATT INSTA HOT WITH DUAL LEVER DISPENSER FOR HOT AND FILTERED WATER RESPECTIVELY. P-4 BAR SINK COUNTER MOEN 22127 16X14 20 GA 301 SS MOEN CA8278 BAR FAUCET 2" 2" 1/2" • 1/2" 208 P -5 . LAVATORY WALL KOHLER K- 2006 -0 FAUCET: SYMMONS S -6080 - G 2" 2" 112" 1/2" VITREOUS CHINA WITH OVERFLOW, WHITE, WITH HANGER, SENSOR ACTIVATED FAUCET WIGRID STRAINER. P -6 DISHWASHER FLOOR BY OTHERS - - 1/2" 1/2" PROVIDE TAILPIECE DISHWASHER CONNECTION FOR WASTE. P -7 ICE MAKER FLOOR BY OTHERS 3/4" - - 1/2" RUN DRAIN TO INDIRECT WASTE FLOOR SINK OR HUB DRAIN. P -8 SHOWER FLOOR AMERICAN REINFORCED PLASTICS 36" STALL S -3637 WITH T2152 MOEN FAUCET AND SHOWER HEAD. GLASS SHOWER DOOR BY OTHERS. 2" 2" 1/2" 1/2" GLASS. SHOWER DOOR BY OTHERS. P -9 WALL HYDRANT EXTERIOR WALL WOODFORD 67R WALL HYDRANT. - - - 3/4" VACUUM BREAKER/FREEZELESSIFOR TILT UP CONSTRUCTION. P10 WATER FILTER WALL PENTEK DUAL CARTRIDGE FILTER HOUSING W /10 MICRON PRE - FILTER AND 5 MICRON CARBON FILTER - - - 3/8" P11 `' FLOOR SINK FLOOR ZURN Z1970 -2 9 "DIA 3" DEEP SANI FLOR RECEPTOR WITH 1/2 GRATE ` 2" 2" PROVIDE TRAP PRIMER P12 FLOOR DRAIN FLOOR ZURN Z- 41 -P112 W/TYPE B NICKEL BRONZE ROUND STRAINER 2" 2" - PROVIDE TRAP PRIMER ELECTRIC WATER HEATER SCHEDULE UNIT NO SERVICE & LOCATION MANUFACTURER & MODEL NO. CAPACITY (GAL) HEAT IN VOLTAGE RECOVERY WEIGHT (LBS) NOTES KW V GPH AT 80F RISE WH -1 FIRST FLOOR RM142 RHEEM EGSP6 6 2.5 208 13 90 1 WH -2 SECOND FLOOR RM205 RHEEM EGSP6 6 2.5 208 13 90 • 1 WH -3 SECOND FLOOR RM273 RHEEM EGSP10 10 4.5 208 23 140 1 WH-4 FIRST FLOOR RM 106 RHEEM EGSP6 6 2.5 208 13 90 1 1. ABOVE CEILING WITH DRAIN PAN GENERAL PLUMBING NOTES 1. ALL PLUMBING SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES: CODES, RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF TUKWILAAND THE 2006 UNIFORM PLUMBING CODE. 2. PLUMBING FIXTURES SHALL BE DESIGNED OR EQUIPPED TO MEET THE FOLLOWING WATER USE EFFICIENCY STANDARDS: A. WATER CLOSETS (TANK STYLE OR FLUSH VALVE) 1.6 GPF B. URINALS 1.0 GPF C. SHOWER HEADS & BATHROOM FAUCETS 2.5 GPM D. LAVATORY & KITCHEN FAUCETS 2.5 GPM SINK & LAVATORY DRAINS SHALL BE CHROME PLATED 17 GA. BRASS TUBING BY ENGINEERED BRASS, DEARBORN BRASS OR BRASS CRAFT. PROVIDE INSULATED P -TRAP & SUPPLY COVERS (TRUEBRO OR EQUAL) AT ALL EXPOSED P -TRAPS & SUPPLIES PER A.D.A STANDARDS. 3. PLUMBING FIXTURES MOUNTING SHALL COMPLY WITH CONTRACT DOCUMENTS & WASHINGTON STATE BUILDING CODE "WAC 51-40" (ACCESSIBLITY EFFECTIVE JULY, 1998. 4. INSTALL WATER HAMMER ARRESTORS ON HOT OR COLD WATER PIPING OF EACH FIXTRUE GROUP & AT ALL FIXTURES WITH QUICK ACTING VALVES, UNITS SHALL BE EQUAL TO ZURN "SHOCKROLL ". SELECT UNIT SIZE & LOCATION PER MANUFACTURERS RECOMMENDATIONS & IN ACCORDANCE WITH PDI STANDARD WH -201. PROVIDE ACCESS PANELS AT ARRESTORS ABOVE GWB CEILINGS. ALL ACCESS PANELS & DOORS SHALL BE ELMDOR FAB, STEEL SLK SERIES OR EQUAL WITH 14 GA DOOR & FRAME. PROVIDE WITH CYLINDER LOCK, CONTINUOUS PIANO HINGE, AND PRIME COATED READY FOR PAINTING. 5. COLD WATER & HOT WATER PIPING SHALL BE INSULATED & ROUTED FULL SIZE WITH APPROPRIATE SIZE REDUCTION INSULATED & AT POINT OF CONNECTION TO FIXTURE. 1/2" WATER LINE LIMITED TO 10'-0" DISTANCE FROM FIXTURE "DEADLEGS" OR "FUTURE STUBS" ON ACTIVE POTABLE WATER LINES. SHALL BE LIMITED TO 4" TO PREVENT STAGNANT WATER CONDITIONS. 6. INSTALL WATER PIPING ON WARM SIDE OF BUILDING INSULATION. SEE SPECIFICATIONS FOR INSULATION SYSTEMS. SEE DRAWINGS FOR ELECTRICAL HEAT TRACE REQUIREMENTS. SEE PLUMBING DETAILS FOR PIPE HANGER STYLE. SEE SPECIFICATIONS FOR HANGER SPACING. 7. BURIED WASTE AND VENT PIPING SHALL BE MIN. 2" DIA. & SLOPED 114" PER FOOT UNLESS OTHERWISE NOTED. PVC OR ABS PIPING SHALL BE USED ONLY AFTER APPROVAL OF ADMINISTRATIVE AUTHORITY, ALSO SEE SPECIFICATIONS. 8. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS EXCEPT IN SHOWER STALLS OR OTHERWISE NOTED ON DRAWINGS. CONTRACTOR SHALL INSTALL ACCESS PANELS AT PRIMERS THAT ARE CONCEALED IN WALLS. 9. COORDINATE VENT THROUGH ROOF (VTR) LOCATIONS WITH HVAC UNITS. MAINTAIN MIN 10' -0" CLEARANCE. OFFSET VTR AS NECESSARY. COORDINATE PIPE ROUTING WITH HVAC & SPRINKLER CONTRACTOR. 10. INSTALL WATER HEATERS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND SET OUTPUT TEMPERATURE TO 115°F UNLESS OTHERWISE NOTED. CONTRACTOR SHALL INSURE GAS VENT FLUES AND COMBUSTION AIR DUCTS ARE WITH MANUFACTURERS LENGTH RECOMMENDATIONS FOR ELECTRIC. WATER HEATERS SET ON CONCRETE FLOORS PROVIDE R -10 INSULATION PAD. 11. RISER DIAGRAMS AND PLANS DO NOT SHOW SOME PIPING OFFSETS REQUIRED FOR STRUCTURAL CLEARANCES. EXACT ROUTING MAY VARY FROM THAT SHOWN. 12. ALL HORIZONTAL DRAINS SHALL BE PROVIDED WITH A CLEAN -OUT LOCATED NO MORE THAN 100 FEET APART. 13. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THE 2006 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2.3- 1416.2.6.3. 14. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2006 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2- 1416.2.3. 15. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE W /IBC, IMC & SMACNA SEISMIC STANDARDS. 16. PROVIDE PIPE INSULATION PER 14 -6 WSEC. 17. PROVIDE 5 DEGREE 5 DEADBAND W/ AUTO SETBACK PER WSEC. 18. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICAL SYSTEMS PER WSEC TABLE 14-4. 19. EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT. 14tOO ( RECEIVED JUL 28 2010 PERMIT CENTER DRAWING SCHEDULE DWG. DESCRIPTION P -001 PLUMBING GENERAL NOTES, LEGENDS, AND SCHEDULES P -101 FIRST FLOOR PLUMBING PLAN P -102 SECOND FLOOR PLUMBING PLAN P -103 ROOF PLUMBING PLAN P -201 DETAILS �,nGtp �W© CaN"TilEt1/416 z 0 0) REV. NO. /DATE z 0 w 0 0 z W W J D r:zo C - W W Lu Q �n z `J Q Z - W Z Z= Z E W Z D 0 O _! w U O 18100 ANDOVER PARK WEST TUKWILA, WA 98138 ISSUE DATE: 7/23/10 JOB. No. 1922 DWG. PURPOSE: CD SET P -001 SHT. 1 OF 5 s - 0 0 Cn 1, 2 122 U. ( 4 ) ,„.2.X,OONNECT_TO,...47„..RISER„„„PROMO UNDER SHELL AND CORE WHICH IS TERMINATED 111-0" ABOVE FFL. .. ^ .... ... .... ..... ( 6 ) 3/4" RELIEF AND DRAIN, DOWN T9 FLOOR SINK. FLOOR SINK FOR ICE MAKER INSTALL FLUSH WITH FLOOR P-11 ;:•••• ....... WITH DRAIN PAN ABOVE CEILING. -(P-10 CARTRIDGE WATER FILTER SEE DETAIL 2"W FROM SECOND FLOOR. HUB „ . DMIN 71 "CW ‘-4• W RISER UP TO VIR. TiC 3/4" RELIEF AND DRAIN DOWN TO APPROVED AIR GAP FITTING BELOW SINK. WITH DRAIN PAN ABOVE CEILING. CARTRIDGE WATER FILTER SEE DETAIL L . . ... ... • ' • • ' • • • . • : ............. 73"CW CONNECT IO 2»CW PROVIDED UNDER CORE AND SHELL ■■•••••••■•.■ • 1 H. 7 3/47CtsDNACWALLTO:SERVE: WALL HYDRANT :•• POC CONNECT TO 2 CW PROVIDED 3/4" ".: FIRST FLOOR PLUMBING PLAN SCALE : 1/8" = 1'-0" 2"V UP 2"W DN 1/2"HW/OW FROM ABOVE. 1:1 g .!:. OPEN TO 2"W UP TO SHOWER D Ors 4 ECEIVED JUL 28 2010 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED 1 0 Z ci) _1 2 D < F— 0 Z L1.1 _1 Z Z (/) 0 (2 o LT_ 18100 ANDOVER PARK WEST TUKWILA, WA 98138 *ISSUE DATE: 7/23/10 JOB. No. 1922 DWG. PURPOSE: CD SET P-101 SHT. 2 OF 5 ■...— z 0 (7) 1 0 Z ci) _1 2 D < F— 0 Z L1.1 _1 Z Z (/) 0 (2 o LT_ 18100 ANDOVER PARK WEST TUKWILA, WA 98138 *ISSUE DATE: 7/23/10 JOB. No. 1922 DWG. PURPOSE: CD SET P-101 SHT. 2 OF 5 ■...— ,..• • O 0._ 0 RANDY STABNOW CO I- Z 4 4 .......................................... ............................... PROVIDE APPROVED AIR GAP -'-- -- �FlTTING- BELOW' SINK: — " 1/2" DHW /DCW DN TO 1ST FLOOR z 4"V 4"V DN. 2"V 4"W RISER UP TO VTR. 4"W RSER• U TO VTR r (P -6) N- 3 /4 "CW P#PE?3J4" RELIEF AND DRAIN PAN SEPARATELY TOLAPPROVED AIR GAP FITTINGS BELOW SINK. PROVIE VACUUM RELIEF VALVE. CARTRIDGE `WATER ALTER SEE DETAIL 2" V FROM FIRST FLOOR UPTOVTR L_ 2"V } N 1 2V DCW CONNECT TO 2 "CW PROVIDED UNDER:CORE AND SHELL. • (P -to) .CARTRIDG.E:WATER. :TER: SE- DETAIL r 2"V FROM -� FIRST. FLOOR_.... PROVIDE APPROVED AIR GAP:FITTINGS........ BEL • 1. /2 "....HW /CW PIPE<:REUELAND .D.RAIN_.P..ANW.SEPARATELY TO HUB DRAIN BELOW SINK. PROVIDE VACUUM RELIEF VALVE. PROVIDE TRAP PRIMER FOR HUB DRAIN. 2" VTR 1/2" CW 3/4" NW 3/4" DRAINS PIPE ::ICEMAKER DRAIN IN ;WALL TO HUB DRAIN BELOW SINK. SECOND FLOOR PLUMBING PAN SCALE : 1 /8" = 1' -0" ee. 8 n Dix ( A I x L RECEIVED JUL 28 2010 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED z 0 w 0 z z 0 w 0 z 9322 14th Avenue South Seattle, WA 98108 -5102 206.764.9663 800.767.9763 psfmechanical.com Z 0 Z D J o- �O <0 Z I�— w o Z Z �- O Z U O w U v) 18100 ANDOVER PARK WEST TUKWILA, WA 98138 ISSUE DATE: 7/23/10 JOB. No. 1922 DWG. PURPOSE: CD SET P -102 SHT. 3 OF 5 • — — -, TEATIME: 07/23/20 ( 5 ) geNli iv! J ROOF PLUMBING P.AN SCALE : 1/8" = 1' -0" RECEIVED JUL 28 2010 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED Z -J o -w Z wJ z0- I U- z O 0 O D 18100 ANDOVER PARK WEST TUKWILA, WA 98138 'ISSUE DATE: 7/23/10 • JOB. No. 1922 DWG. PURPOSE: CD SET P -103 SHT. 4 OF 5 • ■ Z 0 U) Z -J o -w Z wJ z0- I U- z O 0 O D 18100 ANDOVER PARK WEST TUKWILA, WA 98138 'ISSUE DATE: 7/23/10 • JOB. No. 1922 DWG. PURPOSE: CD SET P -103 SHT. 4 OF 5 • ■ RANDY STABNOW P gRX AT L ECEIVED JUL 28 2010 ERMIT CENTER SEPARATE D PERMi pPROVAL REQUIRED / / / \ I . \- \- 2"V I 2°V N I ` \ I 'N 2"V ( \ 2y 21RR 4'VTR I 211 /4 / \ / \ / �- 2b \ I I EXISTING 6" T 211 UP ` \ 2"V \ / 4" SHELL & CORE WASTE r, / P -5 FROM BREAK \ ROOM 142 \ / I ..'% I \ 211 11/2"V / EXISTING 2" 2'V 1..%%-. I I 'N r 2"YV \ cP -,2) P -12 < <t � � 2"W !"- 2.V 2y I I m 4" RISER SHELL & FROM WASTE AND VENT RISER FOR P -3 AT BREAKROOM 238 f 21/� > »- 6 .. 2 - 2"V FROM BELOW I I 2"W . 2'YV 2"W C/O • " 4'W EXISTING 4' ter �w� . DOSING 2" J EXISTING 4" NOTES: 1.EXISTING U/G PIPING BY SHELL AND CORE. WASTE AND VENT RISER AT COFFEE 106 AND RR 104 � .. � P -8 2"W WASTE AND VENT RISER FOR BREAKROOM 273 AND RR 368B : 2' W % 4"W w NOTES: 1.CONNECT DISHWASHER TO TRAP TAILPIECE AT RESPECTIVE P3 SINKS. 2.BELOW SLAB PIPING FURNISHED UNDER SHELL AND CORE. WASTE AND VENT RISER FOR BREAK RM 142 © DETAIL O. DETAIL © DETAIL 4 DETAIL NTS NTS NTS NTS 1/2" TO I HW /CW FlRST \ DOWN FLOOR . \ \ \ 1/2" HW / / L 3/4" CW 060- 3/4" TO R/R 268B I ` & / , � 1 /2 "HW 1 /2 "CW 2° VENT UP ---(=> 3/8' CONN. TO CW TO INSTA HOT AND ICE MAKEF 6'0 HUB / 18" C=1 —► BREAKROOMS 142 AND 273. OTHER LOCATIONS INSTA HC ONLY \ 3/4' ( P -3 3/4' RELIEF IIII \ 1 /2 "CW 1 °C�u THROUGH GGH WASTE SLAB DOWN P -6 / / 40j' . Nolo\I \ .1,00 3/4' RELIEF 3/4" DRAIN (P -5 ) <-3/4"CW P -3 DRAIN DN I P -2 DOMESTIC WATER RISER AT COFFEE 106 1 "CW P -6 273 DOMESTIC WATER RISER FOR BREAKROOM 273 10 MICRON 5 MICRON ACTIVATED POLYPROYLENE CHARCOAL ALTER PRE -FILTER UNDER COUNTER DUAL CARTRIDGE FILTER HOUSING NOTES: 1.PROVIDE TRAP PRIMER. PRE — ACTION SPRINKLER DRAIN 6 DETAIL Q DETAIL O DETAIL 8 DETAIL NTS NTS NTS NTS . 1 /2 "HW ' . 1 /2'CW ■ 3/4' '4110 CW 3/4' CW \ 3/4' RELIEF ' ® 3/4" RELIEF AND DRAIN DOWN 3/4" DRAIN -,41‘040., \ ` 1" CW \ \ \ / \ ( P -3) �1/2" CW 1/2" HW \ ( P-1 ) I ( P-3 ) (P -3) ( P-3) ( P-8 ) P -6) DOMESTIC WATER RISER FOR RR 268 B (P -3 ) DOMESTIC WATER RISER AT BREAKROOM 238 DOMESTIC WATER RISER AT BREAKROOM 142 1 10 DETAIL 9 DETAIL 11 DETAIL NTS NTS NTS ■ tle I 0 % 1 0 1 i F gRX AT L ECEIVED JUL 28 2010 ERMIT CENTER SEPARATE D PERMi pPROVAL REQUIRED _ C 'o v , V °1 2 o Lim 1-11 VI 2 V J z 0 F- 0 �W C J 0 z p Z C� W z z W Z D 0� 0 0_ 18100 ANDOVER PARK WEST TUKWILA, WA 98138 'ISSUE DATE: 7/23/10 S JOB. No. 1922 DWG. PURPOSE: CD SET p P -201 SHT. 5 OF 5 4 S r _ C 'o v , V °1 2 o Lim 1-11 VI 2 V J z 0 F- 0 �W C J 0 z p Z C� W z z W Z D 0� 0 0_ 18100 ANDOVER PARK WEST TUKWILA, WA 98138 'ISSUE DATE: 7/23/10 S JOB. No. 1922 DWG. PURPOSE: CD SET p P -201 SHT. 5 OF 5 4 S