Permit M10-105 - STEMCELL TECHNOLOGIES
STEMCELL TECHNOLOGIES 12698 GATEWAY DR EXPIRED 02 -23 -I1 M10 -105 City otkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 2716000020 Address: 12698 GATEWAY DR TUKW Project Name: STEM CELL TECHNOLOGIES Permit Number: M10 -105 Issue Date: 08/12/2010 Permit Expires On: 02/08/2011 Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: BOB WALL Address: 1411 R ST NW , AUBURN WA 98001 Email: BOB.WALL @AMBIENTCONTROL.COM Contractor: Name: AMBIENT CONTROL CO INC Address: 1020 S 344 ST, SUITE 203 , FEDERAL WAY WA 98003 Contractor License No: AMBIECC 1O1PW Phone: 206 - 510 -9331 Phone: 253 - 661 -5844 Expiration Date: 10/25/2011 DESCRIPTION OF WORK: INSTALL 2 WALK -IN COOLERS COMPLETE WITH COMPRESSORS AND REFRIGERANT PIPING. Value of Mechanical: 121,000.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $1,524.81 International Mechanical Code Edition: 2009 Date: V U I hereby certify that I have read and e ami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ith, whether specified herein or not. The granting of this permit does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. It authorized to sign and obtain this mechanical permit. Print Name: 019 0-1- 71- Date: P—,^6)' ,77‘' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -105 Printed: 08 -12 -2010 wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2716000020 Address: Suite No: Tenant: 12698 GATEWAY DR TUKW STEM CELL TECHNOLOGIES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10 -105 ISSUED 08/03/2010 08/12/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are NOT APPROVED as submitted. The following concerns must accompany the plans in order to properly evaluate: 14: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) (EXTEND SPRINKLER PROTECTION TO THE WALK -IN COOLER/FREEZER.) 15: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) doc: Cond -10/06 M10 -105 Printed: 08 -12 -2010 • wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 18: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -105 Printed: 08 -12 -2010 • i �J,�,� wqs City of Tukwila C y Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: G%G / Date: e?'\ Print Name: ? 61:r i^ C,CN / V doc: Cond -10/06 M10 -105 Printed: 08 -12 -2010 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa. us Mechanical Permit No. I" ` 10— I 0 5 Project No. MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: /oR 6 ! 8 Lea r- Tenant Name: S�e LA.-‘ t t°c vl H :ley r,C Property Owners Name: J King Co Assessor's Tax No.: I (PO Q 00).0 Suite Number: New Tenant: Floor: Yes ❑..No Mailing Address: City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: (A 9Q .' Day Telephone: ?& -S /2 — 9'33 Mailing Address: 1 4 ( R t- 7✓ e6-+ w , & b ttf y-\ WO,/ L I City State pay Zip E -Mail Address: 'b . wa U . ©Livv\� ��- ,�CU-t l e (•mow) Fax Number: c2 3'-g/� -- Z2y MECHANICAL CONTRACTOR INFORMATION Company Name: t) t ‘P r } •--,4 ( C Mailing Address: /4(// E S7`F'E0 f rr■ City Day Telephone: Contact Person: 10 k Lcer I E -Mail Address: G)e IA) a < 7ct wt I0,�e�'�-cv� %t� cov -� Fax Number: Contractor Registration Number: FS wt Z T P e-/121 ?� t44 State 9Kcv I Zip Po(9 - "7— 933/ F 3 6/ Expiration Date: /0 /6- / D ARCHITECT OF RECORD - All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be stamped by engineer of record Company Name: Mailing Address: Contact Person: E -Mail Address: H: ApplicauonsWomts- Appiicanons On Linc\2010 Apphcauons17 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bit City Day Telephone: Fax Number: State Zip Page 1 of 2 • • PIS Valuation of project (contractor's bid price): Scope of work (please provide detailed information). j, --7.5 �7 ��r1�r�,p r1°5f 1 C \7 /A�A r �i[/kl�S.s Use: Residential: New ❑ Replacement Commercial: New Replacement Fuel Type: Electric Er Gas 0 Other: Indicate type of mechanical work being installed and the quant'ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/waWfloor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp/1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic e menhanical eqgher uipment air handling unit <10,000 cfm incinerator — comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN AU Signature: D AGENT: Print Name: RA P/+ - (.-c2c( (1 JNi Mailing Address: /S' // R Date: `� Day Telephone: a, cf %tS' City State Zip Date Application Accepted: .3 _(0 Date Application Expires: Staff Initials: k'r \ H:\Applicanons\Forms- Applications On Line12010 Applications17.2010 - Mechanical Pencil Application.doc Revised: 7 -2010 his Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 2716000020 Address: 12698 GATEWAY DR TUKW Suite No: Applicant: STEM CELL TECHNOLOGIES RECEIPT Permit Number: M10 -105 Status: PENDING Applied Date: 08/03/2010 Issue Date: Receipt No.: R10 -01471 Payment Amount: $1,524.81 Initials: WER Payment Date: 08/03/2010 08:40 AM User ID: 1655 Balance: $0.00 Payee: ROBERT WALL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 087181 ACCOUNT ITEM LIST: Description 1,524.81 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 PLAN CHECK - NONRES 000.345.830 Total: $1,524.81 1,219.85 304.96 doc: Receiot -06 Printed: 08 -03 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit to PERMIT NO. • • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)•431 -3670 Permit Inspection Request Line (206) 431 -2451 Yt- Project: (491A. t Typ�of Inspection: /� t ej {Address - i 2.,(4P 5 g 6.4:49-64-1A7 04, Date Call _ ,,,„, Special Instructions: Date Wanted:, - [ - r0 p.m. Requester: Phone No: Approved per applicable codes. ° Corrections required prior to approval: COMMENTS: • r ter 609e) a _ 3.g a A. Date: ri REIN E ON FEE REQUIRE Priorto next inspection. fee must be paid it 63►' Soutthcenter Blvd.. S ite'100 Call to schedule reinspection. $,� •• Rooftop Plan 3 a 0 (Cfl tiTi 0 d CO m C) m C Roof top Condoner Roof top Cond•nsor Roof top Cond.nsor i i i i JUL Gateway Corporate Center - BLDG 2! Available Tenant Space = 15,288 SF Warehouse = 10,568 SF: Office = 4,720 SF; v al .^..) -ye :1219.7 E., atm g°31 E-8), 000 r I RECEIVING I I Puking Table FREEZER 44' X 24' Packing Table 111111111111111111111111 Box Staging U31N30111183d Gateway Corporate Center - BLDG 2-, Available Tenant Space = 15,288 SF. Warehouse = 10,568 SF, Office = 4,720 SF . _ ..... • SPECIFICATIONS Indoor freezer (with floor) NSF Foam Gasket, Cam -lock layout #2 WCND - Pin Housing WALL PANELS Construction: Exterior Finish: Interior Finish: Ceiling connections: Floor connections: 4" high density urethane 26 ga. stucco white 26 ga. stucco white Cam -lock Cam -lock CEILING PANELS Construction: 4" high density urethane Exterior Finish: Metal Interior Finish: 26 ga. stucco white Ceiling Caps: Factory mounted Live Load: 10 psf FLOOR PANELS Model: SOON (NSF) Construction: 4" high density urethane w/ .080 smooth aluminum @ interior over 1/2" plywood w/ Metal @ exterior Ramp: (2) ea. 36" deep model #500I interior ramp DOORS (A)(B): 36" x 78" flush model G3 self - closing freezer door * ** PLUG WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE Frame: 4" high density urethane, 3 -sided w/ 26 ga. stucco white (ext. & int.) w/ 24 ga. stainless steel 430 (magnetic) liners w/ 3 -sided heat cable in frame [FL- 3 -88W) (33' - 1" of 5 ohms wire @ 2.7 watts /ft) (w/ PEPI thermoswitch, 120V, O.8A) Plug: 3 -side laps, 4" thick w/ 26 ga. stucco white (ext. & int.) w/ Magnetic gasket w/ Heated sweep (self - regulated cable, 120V, 0.3A max.) (2) Kason #1248A spring assisted adjustable hinges (1) Kason #27C cylinder locking handle (1) Kason #27C twist -off knob inside release (1) Kason #1095 spring action door closer w/ door stop (1) Toggle switch w/ pilot light @ ext. (1) Digital 2" flush mount dial thermometer w/ 12" capillary (2) Terminal J -box @ interior w/ concealed conduit (1) Kason 1832 heated air vent (115V, .2A, 23W) (1) .080 smooth aluminum threshold PARTS (10) ea. 4' fluorescent fixture for cooler application (bulbs not included) CEILING SUPPORT (2) ea. 5 1/8" x 13 1/2" x 23' -11" Glu -lam beams (4) ea. 5 1/8" x 48" Spreaders (28) ea. 12" x 32" Tongue and groove hanger straps (6) ea. 3" x 66" x 20 ga. Stucco galv. beam straps REVISIONS #1. Both doors relocated, left hinge for both doors, reduced height to 8' -0 ". COMPONENT NSF LABEL N.S.F. LISTED (STD #7) N.S.F. GASKET @ ALL PANEL JOINTS 44,723 BTU's @ 18 Hrs THE MINIMUM BTU'S SHOWN ARE BASED ON NSF STANDARD #7, SECTION 5, PARAGRAPH 5.36.7, REQUIREMENTS (REF. TABLE 1). THESE NUMBERS ARE NOT INTENDED TO BE USED FOR SIZING OF REFRIGERATION UNITS FOR THIS WALK -IN. IMPERIAL MFG RECOMMENDS CONSULTING WITH A QUALIFIED ENGINEER OR CONTRACTOR. 44-0" [528J 14-8" [1761 14$ [176] 14S (176] 4 3/4 co Fm- c9 n n r. co CO D 47 47 47 47 47 47 47 47 47 47 23 29 1/2 o r` W24 W16 43/4 47 W25 W26 W27 x x 20 ga geN. beent,aa@?72"do Typ 413 i W15 W14 W14 ( i I 47 47 47 W28 W12 W29 FREEZER W30 3"x66"x20gag31v. Seri braze @ 72" do Typ. 413 W 1 1 W 1 0 FILE COPY Permit No., AMW1,o" Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy and • • sip - : is a knowiledged: By Date: '—/2--/Q City Of Tukwila BUILDING DIVISION 47 47 47 W31 T us IW9 47 W32 W33 W34 SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical fI Electrical rla Plumbing to Gas Piping City of Tukwila BUILDING DIVISION W8 W7 47 383/4 W35 CODE API AUG CitY BUILD! 3 ro [A) D1; PNL 321316 N N e v a co In co 43/4 WALL PANELS REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. MlO(OS RECEIVED AUG 03 2010 PERMIT CENTER ZWED FOR PLIANc 092010 ^.-- 6f bola 4G DIVjcinAl M U 1 < THERMAL SUPPLY, INC. - FIFE, WA STEM CELL TECHNOLOGIES - TUKWILA, WA J COSTS MAY BE INCURRED. NOTE MANUFACTURER IS NOT RESPONSIBLE FOR ELECTRICAL PLUMBING, PERMITS OR CONCRETE WORK UNLESS USTED ON THE QUOTE. a lio ermal SUPPLY INC. REV# DATE HT 07/14/2010 BS ' DO NOT SCALE THIS DRAWING SCALE 3/16• = 1' -0" DATE DRAWN: 6/25/2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK'D BY: FR 07/16/2010 DRW#: 10.KS- 32343 -02 BOX 2 OF 2 SHEET: 1 OF 5 I, W4 W3 W2 1<' 315/6 515/4 W,2 1R T -8' (921 Door frame height EELEVATION 2 61/2 61/2 m 33,4 rn [A] I 61/2 612 60 COMPONENT LOCATION 0 6 V2 33,4 1c °I [B] I' 612 - WARNING - TO PREVENT ELECTRICAL DEVICE FAILURE After wiring devices, ALL conduits must be sealed to stop moisture transfer through electrical raceways. Failure to seal device per NEC codes WILL VOID WARRANTY W15 W14 W13 9' -2' [110] (Typ. ®2) W12 W11 W10 W9 W8 31 5/6 31 5/6 W7 12 J. 1R R. L T-8' [92] Door frame height ()ELEVATION 2 CODE REVIEWED FOR APP OV D AUG 0 9 2010 City of Tukwila BUILDING DIVIRinP RECEIVED AUG 0 3 2010 PERMIT CENTER CI 4 M U) NOTE: TO PREVENT CONDENSATION, THERE MUST BE A MINIMUM CLEARANCE OFT FROM THE WALK -IN EXTERIOR SURFACE. HIGH HUMIDITY CONDITIONS MAY REQUIRE FORCED VENTILATION IN ADDRION TO CLEARANCE. n 0 ermal `� `� SUPPLY INC. REV// DATE BY 07/14/2010 BS DO NOT SCALE THIS DRAWING SCALE 3/16' =1,-0° DATE DRAWN: 6/25/2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK'D BY: FR 07/16/2010 DRW#: 10-KS-32343-02 BOX: 2 OF 2 SHEET: 2 OF 5 J31N3011VVH d c G7 CAD 0 IV m m S'IiNVd ENI'II33 15 5/16 26 21 1/16 26 21 1 /16 26 21 1/16 19 7/16 6 3/8 21 1/16 26 21 1/16 26 21 1/16 26 21 1/16 7 5/16 18 5/8 21 1/16 26 21 1/16 17 3/4 21 1/16 35 15 5/16 A 26 5/16 47 47 47 47 C) V Q co C) N C) A C) N C) N 0 A 2 4f 2 N 2 -. N N N O STEM CELL TECHNOLOGIES - TUKWILA, WA co m N L -- N O 0 10 n a n V C) IT n N - -J CO 83:1 C B ' c P,c -±-9, G.,, c 0= a 4'00 si- c fill -1 c=, XI ON A ON m SPL 9T /ST EZ SPL 15 5/16 26 21 1/16 26 21 1 /16 26 21 1/16 19 7/16 6 3/8 21 1/16 26 21 1/16 26 21 1/16 26 21 1/16 7 5/16 18 5/8 21 1/16 26 21 1/16 26 22 1/16 19 9/16 13 1/2 8 DRAW: 10 -KS- 32343 -02 BOX: 2 OF 2 SHEET: 3 OF 5 DATE DRAWN: 6/25 /2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK'D BY: FR 07/16/2010 u b THERMAL SUPPLY, INC. - FIFE, WA 0 ermal ■100 SUPPLY INC.. 07/14/2010 DATE STEM CELL TECHNOLOGIES - TUKWILA, WA NOTE: TO PREVENT CONDENSATION, THERE MUST BE A MINIMUM CLEARANCE OF ? FROM THE WAUC -IN EXTERIOR SURFACE. HIGH HUMIDITY CONDITIONS MAY REQUIRE FORCED VENTILATION IN ADDITION TO CLEARANCE. NOTE: FLOORS OF INSTALLATION SITES SHALL BE TRUE AND LEVEL WITHIN 3116' PER 10' OR ADDITIONAL COSTS MAYBE INCURRED. NOTE MANUFACTURER IS NOT RESPONSIBLE FOR ELECTRICAL, PLUMBING, PERMITS OR CONCRETE WORK UNLESS LISTED ON THE QUOTE q T /� S B Q I I T ' rt L 1 B v ��p} 1 z rn P S'13 2IOO'13 15 5/16 26 21 1/16 26 21 1/16 22 1/2 21 1/16 26 21 1/16 26 21 1/16 13 3/8 12 9/16 21 1/16 26 21 1/16 26 21 1/16 21 3/4 21 1/16 17 3/4 10 1/2 8 26 5/16 47 47 47 47 47 26 5/16 V Obi N A CC.) N T. A 11 W 17 N 71 11 O II co m co N F20 f° 18 9/16 10 1/8 11 CO 03 I' V r W • N 183/16y F28 105/16 _ v 8 105/16 F27 8 O0 ) N �' W- �-. A a) -o 229/16 •••• 12 30 7/16 N N C4 30 7/16 o 12 N 1 °i 1 10 N . o „ °p1 °' 1° 41/8 10 1/2 26 m 10 12 73 3/8 335/8 rn .ES — r CO 0 47 SPL 0 26 5/16 SPL 0 10 SPL /16 36 21/2 561/8 8 15 5/16 26 21 1 /16 26 21 1/16 22 1/2 21 1/16 26 21 1/16 26 21 1/16 13 3/8 12 9/16 21 1/16 26 21 1/16 Of 26 21 1/16 21 3/4 21 1/16 26 16 1/16 5 15/16 19 9/16 13 1/2 8 101/16 43/4 a ON a DRAW: 10 -KS- 32343 -02 BOX 2 OF 2 SHEET: 4 OF 5 DATE DRAWN: 6/25 /2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK'D BY: FR 07/16/2010 m n l (4)1/ THERMAL SUPPLY, INC. - FIFE, WA 07/14/2010 o g STEM CELL TECHNOLOGIES - TUKWILA, WA OM Clime • I = Z �r NOTE: TO PREVENT CONDENSATION, THERE MUST BE A MINIMUM CLEARANCE OFT FROM THE WALK -IN EXTERIOR SURFACE. HIGH HUMIDITY CONDITIONS MAY REQUIRE FORCED VENTILATION IN ADDITION TO CLEARANCE. NOTE: FLOORS OF INSTALLATION SITES SHALL BE TRUE AND LEVEL WITHIN 3/W PER 10' OR ADDITIONAL COSTS MAY BE INCURRED. NOTE MANUFACTURER IS NOT RESPONSIBLE FOR ELECTRICAL PLUMBING, PERMITS OR CONCRETE WORK UNLESS LISTED ON THE QUOTE q /� 1 1 _ v IL ' 1"—T tb C 12' Wide Galv, steel hanger strap In between every cam lock Bend over beam as shown and nail (5) 'Teco' structural nails (4) #10 x 3/4' PHSMS @ CEILING PANEL i MINN MIN INSINI (5) 16d Galv nails OBEAM SECTION DETAIL (NTS) (2) #14 x 1 1/2' PHSMS @ BEAM 3' x 66' 20 GA GALV. BRACES @ 6' -0' 0. C. @ BOTH SIDES OF ALL GLU -LAM BEAMS. C)BEAM BRACE DETAIL (NTS) Glu -Lam beam Ceiling panel 3/8'0 x 10' lag Typ. @ 2 L 3 1/2' x 3' x 1/4' @ both sides of beam (2) #14 x 1 1/2' phsms ea. s i de ( staggered) Shop weld 11 paint L 3' x 3 1/2' x 48' beam spreader Ceiling panels OBEAM SPREADER DETAIL (NTS) Wall panels .080 Smooth aluminum 13/4 387/8" NOTE: Do to construction variables seal threshold /jamb joint v/ silicone Edgedreteis 36 Rap nctch 37314- (NM + 1/8') Will +1/8' Offset stop Y Door frame Flush door framed beyond 3/4' Plywood Threshold —. R 1 13/4 Wear surface w/ non -skid strips Floor panel 36 derlayment when specified see floor spec. OPRE -5 FAB FLOOR w/ 36" DEEP INTERIOR RAMP Flush door REVIEWED FOR CODECOMpLI� APPROVED MI5 0 9 2010 BUILDING of Tukwila DINC M RECEIVED AUG 03 2010 PERMIT CENTER H 11 III U) TI-INIMAL SUPPLY, INC. - FIFE, WA STEM CELL TECHNOLOGIES - TUKWILA, WA COSTS MAYBE INCURRED. NOTE MANUFACTURER IS NOT RESPONSIBLE FOR ELECTRICAL, PLUMBING, PERMITS OR CONCRETE WORK UNLESS LISTED ON THE QUOTE. �ermal •■....../ SUPPLY INC. REV# DATE BY 07/14/2010 SS DO NOT SCALE THIS DRAWING SCALE: 3/16' = 1' .0' DATE DRAWN: 6/25/2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK'D BY: FR 07/16/2010 DRW#: 10 -KS- 32343 -02 BOX: 2 OF 2 SHEET: 5 OF 5 SPECIFICATIONS Indoor cooler (no floor) NSF Foam Gasket, Cam -lock layout #2 WCND - Pin Housing SPECIAL INSTRUCTIONS Meets 2009 Federal Energy Independence and Security Act Requirements. WALL PANELS Construction: 4" high density urethane Exterior Finish: 26 ga. stucco white Interior Finish: 26 ga. stucco white Ceiling connections: Cam -lock Floor connections: Angle screed CEILING PANELS Construction: 4" high density urethane Exterior Finish: Metal Interior Finish: 26 ga. stucco white Ceiling Caps: Factory mounted Live Load: 10 psf DOORS [A]: 36" x 78" flush model G3 self - closing cooler door * ** PLUG WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE Frame: 4" high density urethane, 3 -sided w/ 26 ga. stucco white (ext. & int.) w/ 24 ga. stainless steel 430 (magnetic) liners Plug: 3 -side laps, 4" thick w/ 26 ga. stucco white (ext. & int.) w/ Magnetic gasket (2) Kason #1248A spring assisted adjustable hinges (1) Kason #27C cylinder locking handle (1) Kason #27C twist -off knob inside release (1) Kason #1095 spring action door closer w/ door stop (1) Toggle switch w/ pilot light @ ext. (1) Digital 2" flush mount dial thermometer (12" capillary) (1) Terminal J -box @ interior w/ concealed conduit [B]: 52" x 84" overlap model G3 cooler door * ** PLUG WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE * ** Frame: 4" high density urethane, 3 -sided w/ 26 ga. stucco white (ext. & int.) w/ 16 ga. smooth galv. liners Plug: 3 -side laps, 4" thick w/ 26 ga. stucco white (ext. & int.) w/ Magnetic gasket (3) Kason #1277 -16 heavy duty hinges (1 3/4" offset) (1) Kason #56XL standard latch, polished chrome (1) Kason #486A inside release (recessed) (1) Toggle switch w/ pilot light @ ext. (1) Digital 2" flush mount dial thermometer (12" capillary) (1) Terminal J -box @ interior w/ concealed conduit PARTS (10) (12) (17) (1) ea. 4' fluorescent fixture for cooler application (bulbs not included) ea. 2 1/2" x 96" NSF aluminum cove base ea. 96" angle screed ea. Normal temp Chase Doors strip curtain for 52" x 84" net opening w/ 8" strips @ 25.00% overlap CEILING SUPPORT (2) ea. 5 1/8" x 13 1/2" x 23' -11" Glu -lam beams (4) ea. 5 1 /8" x 48" Spreaders (28) ea. 12" x 32" Tongue and groove hanger straps (6) ea. 3" x 66" x 20 ga. Stucco galv. beam straps REVISIONS #1 Changed locations of both doors, made both door swings left, changed overall box height to 8' -0 ", swapped door locations. COMPONENT NSF LABEL N.S.F. LISTED (STD #7) N.S.F. GASKET @ ALL PANEL JOINTS 44,723 BTU's @ 18 Hrs THE MINIMUM BTU'S SHOWN ARE BASED ON NSF STANDARD #7, SECTION 5, PARAGRAPH 5.38.7, REQUIREMENTS (REF. TABLE 1). THESE NUMBERS ARE NOT INTENDED TO BE USED FOR SIZING OF REFRIGERATION UNITS FOR THIS WALK -IN. IMPERIAL MFG RECOMMENDS CONSULTING WITH A QUALIFIED ENGINEER OR CONTRACTOR. 41-0-15231 14.6"[179 43/4 ao n n n DC 47 47 47 47 47 47 47 47 47 22 3/4 T N —m W25 W17 W26 W16 W27 x64" x 2D]g gtv. Learn [race @ 72' o'c Typ. 433 W1 5 W2 i W14 W29 W13 W30 COOLER W31 3" x 64" x 2Oga gals. bean brace 4172' o'c Ti y 433 W12 32 i W11 W10 W33 W9 W34 W8 4013116 72PNL 43/4 [B] co 1 co 3 Q g W7 W6 4 3/4 47 47 47 47 47 47 47 47 47 47 23 29 1/2 MIOlo5 v v a J REVIE CODE c( AI*J AUK r of BUII�AIWG Pi WALL PANELS RECEIVED AUG 0 3 2010 PERMIT CENTER bVED FOR MPLIANCE E OVVD 19 2010 �U i l °M/RAAI► H 11 V L NOTE: TO PREVENT CONDENSATION, THERE MUST BE A MINIMUM CLEARANCE OFT FROM THE WALK -IN EXTERIOR 1 �ermal •..............-, SUPPLY INC. REV# DATE HY 07/09/2010 BS DO NOT SCALE THIS DRAWING SCALE: 3/16" = 1' -0" DATE DRAWN: 6/24 /2010 DATE PRINTED: 7/20/201 D DRAWN BY: BILL STARKS CHK'D BY: FR 07 -15 -2010 DRAW 10—KS-32343-01 BOX: 1 OF 2 SHEET: 1 OF 4 ko [AI W5 W4 W3 W2 W1 )ELEVATION 2 Backing @ mt fcr ship p.1si, 61/2 O [A] 61/2 m 61/2 r L rn f_D 2 m COMPONENT LOCATION [B) 612 c73 - WARNING - TO PREVENT ELECTRICAL DEVICE FAILURE After wiring devices, ALL conduits must be sealed to stop moisture transfer through electrical raceways. Failure to seal device per NEC codes WILL VOID WARRANTY [B) W34 W33 W32 W31 W30 W29 W28 W27 W26 W25 ()ELEVATION 2 CO REVIEWED IEWED FO F COMPLIANCE AmornFD AUti 0 9 2010 City of Tukwila BUILDING nil/lento RECEIVED AUG 0 3 2010 PERMIT CENTER [i 4 III U) J NOTE: TO PREVENT CONDENSATION, THERE MUST BE A MINIMUM CLEARANCE OFT FROM THE WALK -IN EXTERIOR 1 `••••.— ermal SUPPLY INC. REV# DATE BY 07/09/2010 BS DO NOT SCALE THIS DRAWING SCALE 3/16' = 1' -0' DATE DRAWN: 6/24/2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK'D BY: FR 07-15-2010 DRW/k. 10-KS-32343-01 BOX: 1 OF 2 SHEET: 2 OF 4 L31N3911f3d M GI 0 CD C Mil a M O 15 5/16 26 21 1 /16 26 21 1/16 26 21 1/16 19 7/16 6 3/8 21 1/16 26 21 1/16 26 21 1/16 26 21 1 /16 7 5/16 18 5/8 21 1/16 26 21 1/16 26 22 1/16 19 9/16 13 1/2 8 gst C f 13 3/4 47 47 47 r— V0C1 DATE DRAWN: 6/24/2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK9 BY: FR 07 -15 -2010 U) A UUit — N - - - -� e a 2 u 2 ro 2 . A A 2 c d a a UI io 0 co N L— 0 O t0 n co 2 V 2 0) n N ____J a 15 5/16 26 21 1/16 26 V 21 1/16 26 21 1/16 19 7/16 6 3/8 21 1/16 26 21 1/16 26 21 1 /16 26 21 1/16 7 5/16 18 5/8 21 1/16 26 21 15/16 rn 21 15/16 25 1/2 25 1/2 15 5/16 DATE DRAWN: 6/24/2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK9 BY: FR 07 -15 -2010 m n b (() THERMAL SUPPLY, INC. - FIFE, WA 07/09/2010 d a a STEM CELL TECHNOLOGIES - TUKWILA, WA C 11 r 4 g Z P I•r NOTE: TO PREVENT CONDENSATION, THERE MUST BE A MINIMUM CLEARANCE OFT FROM THE WALK-IN EXTERIOR SURFACE. HIGH HUMIDITY CONDITIONS MAY REQUIRE FORCED VENTILATION IN ADDCTION TO CLEARANCE. NOTE: FLOORS OF INSTALLATION SITES SHALL BE TRUE AND LEVEL WITHIN 3/16- PER 10' OR ADDITIONAL COSTS MAY BE INCURRED. NOTE MANUFACTURER IS NOT RESPONSIBLE FOR ELECTRICAL, PLUMBING, PERMITS OR CONCRETE WORK UNLESS LISTED ON THE QUOTE T AS � u I ][ ]L' I 1 �i r v -4 12' Vide Galv. steel hanger strap In between every cam lock Bend over beam as shown and nail (5) 'Teco' structural nails (4) #10 x 3/4' PHSMS @ CEILING PANEL (5) 16d Galv nails 11 BEAM SECTION DETAIL q (NSTS) (2) #14 x 1 1/2' PHSMS @ BEAM 3' x 66' 20 GA GALV. BRACES @6' -0' 0. C. @ BOTH SIDES OF ALL GLU -LAM BEAMS. OBEAM BRACE DETAIL (NTS) Glu -Lam beam 3/8'0 x 10' lag Typ. @ 2 Ceiling panel L 3 1/2' x 3' x 1/4' @ both sides of beam (2) #14 x 1 1/2' phsms ea. side (staggered) Shop weld & paint L 3' x 3 1/2' x 48' beam spreader OBEAM SPREADER DETAIL iNTS) EXT. Wall panel Angle screed INT. #8 x 3/4" FHSMS 2 1/2" NSF aluminum cove base Concrete floor (NIC) CDCOVE BASE DETAIL Over Concrete Floor (NrTS) REVIEWED FOR CODE COMPLIANCE Ac:J 0 y 2U111 RECEIVED AUG 03 2010 PERMIT CENTER L' M U) r NOTE: TO PREVENT CONDENSATION, THERE MUST BE A MINIMUM CLEARANCE OFT FROM THE WALK -IN EXTERIOR 1 go `w� Milummolg ermal SUPPLY INC. REV# DATE HY 07/09/2010 BS DO NOT SCALE THIS DRAWING SCALE: 3/16' = 1'-0" DATE DRAWN: 6/24/2010 DATE PRINTED: 7/20/2010 DRAWN BY: BILL STARKS CHK9 BY: FR 07-15-2010 DRAW: 10-KS-32343-0 1 BOX: 1 OF 2 SHEET: 4 OF 4 A Brand of Heatcraft Refrigeration Products 2175 West Park Place Boulevard Stone Mountain, GA 30087 • 800 - 848 -9889 SUBMITTAL DRAWINGS Models LZ* (3 - 6 HP) Scroll Air Cooled Condensing Unit Project: STEM CELL TECH Arch/Ener BOB WALL Customer: AMBIENT CONTROL Identity: Item No. Location: SEATAC Order No. Model No. LZT060L6CF Q 2 V Date: 8 -22 -10 by TOM ❑ for approval for record a Outdoor (Left View) I«--- -301/4 'Hex "he stets us CO REVIEWED FOR COMPLIANCE APPROVED AUG 0 9 2010 'he x " /1e City of Tukwila BUILDING DivIsIni J PHYSICAL DATA Outdoor (Front View) 421/2 Power Corms: (2) '/e , (1) 1 5/e d (1)1 1/4 29 3/4 Indoor (Front View),..- 43 43 7/a LZ Series Scroll Model Site , Compressor Connections Receiver Cap.(90 %) Net Weight lbs. - Sound Data dba $ ( Model No. HP Liquid inches Suction inches lbs. R- 404A/807 12'030M8 2.621K4E 3 1/2 7/8 20 287 72 12'03018 Z828K4E 3 1/2 7/8 20 290 74 12•045M8 ZS30K4E 4 1/2 1 -1/8 20 317 73 12'055M8 Z838K4E 6 1/2 1 -1/8 20 317 74 o'r =tie -i=Y 4 - 1/2 - /: 20 6 L1•0451-8 ZF13K4E 4 1/2 1 -1/8 20 307 73 1.2'056L8 2F15K4E 5 1/2 1 -1/8 20 313 74 "08018 ZF18K4E 6 /2 -1/8 20 3 7 -8 R -22 LZ•030M6 ZS21K4E 3 1/2 7/8 22 287 72 LZ•035M6 ZS26K4E 3 1/2 7/8 22 290 74 LZ•045M6 V Z830K4E 4 1/2 1 -1/8 22 317 73 LZ•055M6 ZS36K4E 5 1/2 1 -1/8 22 _ 317 74 Lz•06oMS Z645K4E 6 1/2 1 -1/8 22 317 78 LZ'045L6 ZF13K4E _ 4 1/2 1 -1/8 22 307 73 1Z•055L6 2F15K4E 5 _ 1/2 1 -1/8 22 313 74 LZ•O60L6 ZF18K4E 6 1/2 1 -1/8 22 317 Y8 • = T for Outdoor, N for Indoor, 8 for Beacon II E'dms'd sound pressure values ere 10 feel from the unit. For s na0/q sound pressure nom the unit et different distance', deduct the fore -4w horn Me unit •e4we: 20 fee,, d.dual 6 dOs..... lot 40 feet, deduct 12 dbe........tor fro NM, deduce 10 dee This deft ie typical or -free socr. ose dtoni for horizontal air cooled condensing units al the outlet of the discharge air. The equal sound maaduterMde may very depending on ere condensing unit insrw4YOn. Fectore Such W redacting *sec, Oaeirou d noise and mounting Gonda/mu mw have a slprilcan, Influence on tits data. RECEIVE AUG Oa 2010 PERMIT CENTER ©2009 Heatcraft Refrigeration Products, LLC Panel LHTS022809h M � o -105 • PERFORMANCE DATA t Temp . Model Ca • aai BTUH) 95 °F uc ton empera to R� A1507 35° F 30° F 25° F 20° F 10° F 0° F • -5 F 030M8 00 ! 00 27 70 25160 21060 17260 15520 12°035M8 37800 35320 32820 30350 25520 ■ 21010 18930 LZ-045M6 44700 41390 38230 35150 29310 23930 21450 12*055148 51910 48470 45160 41880 35360 29210 28350 LZ -060M6 59580 55880 52340 48730 41500 34510 31240 R-22 18230 LZ'030M6 30740 28360 28040 ._ 23800 19580 - - 121035M6 37430 34440 31570 28820 23580 - - LZ•045M6 44150 40390 38830 33470 27380 - - LZ•055M6 51970 48030 44190 40480 33270 - - LZ`060M6 _ 61220 _ 56690 52230 47880 39810 - - Low Temp Model Capacity (MTUN) at 95°F Compressor Fan Motor " Sucdon empe►ature °F MOPD R- 404A1507 0° F -10° F -15° F Hz .20° F .25° F -30° F - Hp -4o° F LZ`045L6 23740 19490 17590 LZ•0301‘4813 15690 13880 ' 12210 14.7 9380 LZ 055L8 28870 23820 21550 1 19260 17390 15160 LZ•030MSC 11910 LZ•08016 34960 28970 28120 1 23390 20850 18500 38 14520 R-22 12.0 30 12*•030M8D 12°045L6 22370 18230 16320 39.0 14550 12910 11430 15 8950 LZ`055L6 27430 22370 20050 12°035M68 17880 15580 14050 18.6 11000 LZ•0601.8 32190 28240 23490 39 20920 18550 16400 ■ 12800 Note. t Multiply capacity by 1.04 for 90•F Ambient Temperature Or by .95 for 100•FAmbient Temperature us ELECTRICAL DATA Scroll Model Number Pow er 8uppl3 Compressor Fan Motor " MCA MOPD Evap. Fan Amps. Defrost Heater Amps. 30 Volts Ph Hz RLA 1-RA Qty. - Hp Fla Air Elec. Air ` Elec. LZ•0301‘4813 208 -230 1 50/80 14.7 88.0 1 1/3 3.5 22 38 35 45 12.0 LZ•030MSC 208-230 3 50/60 9.9 77.0 1 1/3 3.5 20 38 25 40 12.0 30 12*•030M8D 460 3 50/80 5.1 39.0 1 1/3 1.9 15 24 15 25 0 0 12°035M68 208 -230 1 60/60 18.6 109.0 1 1/3 3.5 27 39 45 ' 50 12.0 30 LZ*035M6C 208 -230 3 50/60 12.2 88.0 1 1/3 3.5 20 38 30 40 12.0 30 12•0351V16D 460 3 50/60 8.4 44.0 1 1/3 1.9 15 24 15 25 a 0 LZ`045M60 208 -230 1 50/60 24.0 129.0 1 1/3 3.5 34 59 60 60 11.0 47 L2'045M6C 208 -230 3 50/60 13.5 99.0 1 1/3 3.5 20 44 30 45 12.0 35 LZ•045M6D 460 3 50/60 7.4 49.5 1 1/3 1.9 15 29 15 30 11.0 23 LZ•055M6B 208.230 1 50/60 " 28.8 169.0 1 1/3 3.5 40 59 60 80 12.0 47 LZ°055M6C 208-230 3 50/80 19.2 123.0 1 1/3 3.5 26 44 45 50 12.0 35 "0 5Mb■ 60 3 5.:. ' a,.. • 1 . • L2*080M5C 208 -230 3 00/60 21.5 156.0 1 1/3 3.5 30 42 50 60 12.0 30 LZ`000M6D 450 3 50/60 8.3 ' 70.0 1 1/3 1.9' 16 29 20 30 10.6 23 12°045L69 208 -230 ., 1 50/80 24.0 129.0 1 1/3 3.5 34 45 50 60 11.0 30 LZ°046L8C 208 -230 3 50/60 13.5 99.0 1 1/3 3.5 20 38 30 45 11.0 30 i . . • D • • • 3 50180 .4 '.5 .- .0 1 L2•055L66 708 -230 1 50/60 'i8 w 169.0 1 1/3 3.5 40 50 50 60 10.0 30 LZ •055L6C 208-230 3 50/80 19.2 123.0 1 1/3 3.5 • 28 40 45 50 10.0 30 L2*055L8D 460 3 60/60 8.7 62.0 1 1/3 1.9 y 15 24 20 25 _ 8.0 19 LZ °060L6C _ 208 -230 3 50/60 21.5 156.0 1 1/3 3.5 30 r 44 _ 50 80 12,0 35 LZ•060L6D 460 3 50/60 . 8.3 70.0 1 1/3 1.9 15 29 20 30 11.0 23 0 Power supplied by customer. 173,JaK , c ucuircra:�11 02009 Heatcraft Refrigeration Products, LLC Panel LHTS022809h 01 -03 -2011 o , o �/ g f � TU � " ' Jim Haggerton, Mayor Depi.z ; ; I ent of Community Development Jack Pace, Director BOB WALL 1411 R ST NW AUBURN WA 98001 RE: Permit No. M10 -105 12698 GATEWAY DR TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by: such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 02/23/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is •determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 02/23/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M10-105 6300.Southcenter Boulevard, Suite #100 ® Tukwila, Washington 98188 a Phone: 206 - 431 -3670 a Fax: 206 - 431 -3665 Contractors or Tradespeople Per Friendly Page I General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AMBIENT CONTROL CO INC UBI No. 601081069 Phone 2536615844 Status Active Address 1411 R St Nw License No. AMBIECC101PW Suite /Apt. License Type Construction Contractor City Auburn Effective Date 10/16/1990 State WA Expiration 10/25/2011 Date Zip 980013506 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses Page 1 of 2 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AMBIECC133Q6 AMBIENT CONTROL COMPANY Construction Contractor Air Conditioning Commercial /Industrial /Refrig 11/2/1987 10/16/1990 Archived CASCADS0330D CASCADE DRAFT SYSTEMS INC Construction Contractor Commercial /Industrial /Refrig Unused 9/4/1997 7/28/2004 Expired Business Owner Information Name Role Effective Date Expiration Date WALL, DENA Cancel Date 01/01/1980 Amount WALL, ROBERT A JR 10 01/01/1980 DTC07224M232COF08 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 OLD REPUBLIC SURETY CO YLI227438 10/16/2001 Until Cancelled $6,000.00 10/25/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 10 CHARTER OAK FIRE INS CO DTC07224M232COF08 10/16/2008 10/16/2010 $1,000,000.00 09/30/2009 9 NORTH PACIFIC INS CO C03161616 10/16/2006 10/16/2008 $1,000,000.0010 /18/2007 8 NORTH PACIFIC INS CO CO2161616 10/16/2005 10/16/2006 $1,000,000.0010 /18/2005 7 NORTHERN INS CO OF NY SCP042626532 10/16/2004 10/16/2005 $1,000,000.0009 /20/2004 6 NORTHERN (ZURICH) INS CO SCP042626532 10/16/2003 10/16/2004 $1,000,000.0010 /02/2003 https://fortress.wa.gov/lni/bbip/Print.aspx 08/12/2010 oPE 1 S PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -105 DATE: 08 -03 -10 PROJECT NAME: STEM CELL TECHNOLOGIES SITE ADDRESS: 12698 GATEWAY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: lucking-uivision ,Q(01 ' 1 Public Works A IK ,4JL 9",-10 Fire Prevention 1g Structural Planning Division Permit Coordinator t DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: ig] Incomplete DUE DATE: 08-05-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IX Structural Review Required REVIEWER'S INITIALS: DATE: No further Review Required APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 09-02-10 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02