HomeMy WebLinkAboutPermit M10-108 - COSTCOCOSTCO
441 COSTCO DR
M10 -108
J��I I L;4 x,1,,
� sy
O 6 E
City Qftukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: //www.ci.tukwila.wa.us
MECHANICAL PERMIT
Parcel No.:
Address:
3623049107
441 COSTCO DR TUKW
Project Name: COSTCO
Permit Number: M10 -108
Issue Date: 08/23/2010
Permit Expires On: 02/19/2011
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
COSTCO WHOLESALE CORP
PROPERTY TAX DEPT 190 , 999 LAKE DR 98027
MICHAEL ATWOOD
9630 153 AV NE , REDMOND WA 98052
MATW OOD @MERITMECHANICAL. C OM
Contractor:
Name: MERIT MECHANICAL INC.
Address: PO BOX 2109 , REDMOND, WA 98052
Contractor License No: MERITMI163CM
Phone: 425 883 -9224
Phone: 425 883 -9224
Expiration Date: 06/01/2011
DESCRIPTION OF WORK:
INSTALL (1) EXHAUST FAN WITH DUCT FOR INDOOR SAND BLASTER.
Value of Mechanical: $2,000.00
Type of Fire Protection: UNKNOWN
Permit Center Authorized Signatur
I hereby certify that I have read a
governing this work will be comp
Fees Collected: $209.63
International Mechanical Code Edition: 2009
Date:
J
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not p
construction or the performance of work.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I • m authorized to sign and obtain this mechanical permit.
Signature:
Print Name: ILIOSI kr1,1411)
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date: 1/7.3 fret()
doc: IMC -4/10
M10 -108 Printed: 08 -23 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
Parcel No.: 3623049107
Address: 441 COSTCO DR TUKW
Suite No:
Tenant: COSTCO
PERMIT CONDITIONS
Permit Number: M10 -108
Status: ISSUED
Applied Date: 08/04/2010
Issue Date: 08/23/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
doc: Cond -10/06
M10 -108 Printed: 08 -23 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: hap://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any
construction or the performance of work.
Signature:
Print Name: M I C.I} -4-{; L 1-7Q01717
Date: 0/24/0
of law and ordinances governing
other work or local laws regulating
doc: Cond -10/06 M10 -108
Printed: 08 -23 -2010
CITY OF TUKWIL
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Mechanical
Project No,
(forrffice use only) "
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: 441 Costco Drive
Tenant Name: Costo
Property Owners Name: Costco Wholesale
Mailing Address: 999 Lake Drive
King Co Assessor's Tax No.: 3623049107
Suite Number: Floor:
New Tenant: ❑ Yes ❑ .. No
Issaquah
WA
98027
City
State
Zip
CONTACT PERS+
your permi
tidy to be
Name: Michael Atwood
Day Telephone: (425) 883 -9224
Mailing Address: 9630 153rd Ave NE Redmond WA 98052
City
Fax Number:
E -Mail Address:
matwood @meritmechanical.com
State
(425) 867 -0962
Zip
MEC.H
TOR INFORMATION
Company Name: Merit Mechanical, Inc.
Mailing Address: 9630 153rd Ave NE
Contact Person:
Redmond
WA 98052
Michael Atwood
E -Mail Address:
matwood @meritmechanical.com
City State Zip
Day Telephone: (425) 883 -9224
Fax Number: (425) 867 -0962
Contractor Registration Number: MERITMI163CM Expiration Date: 06/01/2011
ARCHITECT OF RECORD - All piat
ped by. Arc
Record
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
State
Zip
ENGINEER OF RECORD
Inns must be we stamped by Engineer
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
A Applications \Emus- Applications On Line \2009 Applications VI -2009 - Mechanical Permit Application. doe
Revised: 1 -2009
bh
State
Zip
Page 1of2
Valuation of Project (contractor's bid price): $ 2,000
Scope of Work (please provide detailed information): Install 1 exhaust fan with duct. Fat NS �I )7$1 Q/ /��
T�
Use: Residential: New
Commercial: New
Fuel Type: Electric ❑
to
Replacement
Replacement
Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type
Qty
Boiler/Compressoi'
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
1
Thermostat
15 -30 HP /1,000,000
BTU
Suspended/Wall /Floor
Mounted Heater
Ventilation System
Wood /Gas Stove
30 -50 HP /1,750,000
BTU
Appliance Vent
Hood and Duct
Emergency Generator
50+ HP /1,750,000 BTU
Repair or addition to
Heat/Refrig /Cooling System
Incinerator— Domestic
Other Mechanical
Equipment
Air Handling Unit <10,000
CFM
Incinerator — Comm /Ind
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN OWNER 0 UTHORIZED AG T:
Signature:
Print Name: Michael Atwood
Mailing Address: 9630 153rd Ave. NE
Date: 08/04/2010
Day Telephone: (425) 883 -9224
Redmond
WA 98052
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
g —�--c a
,- -1"+— <
<
li:AApplications\Fonns- Applications On Line \2009 Applications VI -2009 - Mechanical Permit Application.doe
Revised: 1 -2009
bit
Page 2 of 2
• •
City of Tukwila
Department of Coinfminity Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http. //www.ci.tukwila.wa.us
Parcel No.: 3623049107
Address: 441 COSTCO DR TUKW
Suite No:
Applicant: COSTCO
RECEIPT
Permit Number: M10 -108
Status: PENDING
Applied Date: 08/04/2010
Issue Date:
Receipt No.: R10 -01487
Payment Amount: $209.63
Initials: WER Payment Date: 08/04/2010 10:16 AM
User ID: 1655 Balance: $0.00
Payee: MERIT MECHANICAL
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 24280 209.63
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 167.70
000.345.830 41.93
Total: $209.63
PAYMENT
RFCEIVED
doc: Receipt -06 Printed: 08 -04 -2010
INSPECTION RECORD
Retain a copy with permit
INSPEC • NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431=2451
Project '—•
•
Typere Inspetti n:
Address.
it 60S77---O
.34.,
Date Called:
I
Sped I I s ructiOns:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
proved per applicable codes. Corrections-required prior to approvaI.-.
MMENTS:
14> ;
Dat
ECTION FEE REQUIRED. rior to-n t inspection, fee must be
t 6300 Southcenter Blvd/. S ite 100. C ll to schedule reinspection. •
•
• •
PE 1
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -108
PROJECT NAME: COSTCO
SITE ADDRESS: 441 COSTCO DR
X Original Plan Submittal Response to Incomplete Letter #
DATE: 08 -04 -10
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Fp* r �o�'
ull Ing Division gm
Public Works n
Am AO- 9 -s� -ro
ire Prevention
Structural ❑
Planning Division
Permit Coordinator
at
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
[x]
Incomplete
DUE DATE: 08-05 -10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 09 -02 -10
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Peer Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with Lai to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name MERIT MECHANICAL INC UBI No. 600517946
Phone 4258839224 Status Active
Address Po Box 2109 License No. MERITMI163CM
Suite /Apt. License Type Construction Contractor
City Redmond Effective Date 2/14/1984
State WA Expiration Date 6/1/2011
Zip 980732109 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
AUTOMMC044QH
AUTOMATED MECH
CONTROLS INC
Construction
Contractor
General
Unused
11/8/1996
6/1/2010
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
KIRKWOOD, RODERICK V
President
02/14/1984
Bond Amount
KIRKWOOD, JOAN M
Secretary
02/27/2006
08358695
FRICKBERG, WILLIAM MICHAEL
Vice President
02/27/2006
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
10
FIDELITY Et DEPOSIT
CO OF MD
08358695
02/01/2010
Until Cancelled
$12,000.0001
/20 /2010
9
ARCH INS CO
SU1041124
02/01/2009
Until Cancelled
02/01/2010
$12,000.0001
/12/2009
8
TRAVELERS CAS
SURETY CO
081S103546895BCM
07/22/2001
Until Cancelled
02/01/2009
$12,000.0003/07
/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
25
CEOXINGTONINS
049159165
11/01/2009
11/01/2010
$2,000,000.0011
/02/2009
24
CEOXINGTONINS
004052434
11/01/2008
11/01/2009
$2,000,000.00
11/04/2008
23
ACE AMERICAN
HD0G23734941
03/03/2008
03/03/2009
$2,000,000.0003
/10/2008
22
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2007
11/01/2008
$1,000,000.00
10/31/2007
21
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2005
11/01/2007
$1,000,000.00
10/18/2006
20
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2004
11/01/2005
$1,000,000.0011
/01/2004
19
ST PAUL FIRE
MARINE
KC08400069
11/01/2003
11/01/2005
$1,000,000.00
10/27/2004
https://fortress.wa.gov/lni/bbip/Print. aspx
08/23/2010
EXHAUST FAN SCHEDULE
SYMBOL
MAKE & MODEL
DESCRIPTION
CFM
ESP
RPM
SOUND
RATING
ELECTRICAL
WEIGHT
NOTES
SONES
0 DIST.
WATTS
V/PH/HZ
EF-1
FANTECH FKD12
INUNE EXHAUST FAN
1050
0.75
2900
23
531
115-1-60
21
1, 2
NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR BETTER OR EQUAL MANUFACTURER.
2. MANUAL SWITCH, SPEED CONTROL
GENERAL NOTES
1. FIELD VERIFY UNIT LOCATIONS, DROPS, AND POSMONS.
2. MAINTAIN 10'-0" MINIMUM DISTANCE BETWEEN O.S.A. INLETS AND PLUMBING WASTE VENTS, EXHAUST, AND
COMBUSTION AIR OURETS.
3. INSULATE DUCT PER W.S.E.C.
4. SEAL ALL TRANSVERSE DUCT JOINTS.
5. ALL UNE VOLTAGE BY ELECTRICIAN.
6. HVAC SYSTEM IS DESIGNED PER 2006 WSEC, IBC, AND INC.
EXISTING
NEPA
FILTER
SCOPE OF WORK
1. INSTALL 1 EXHAUST FAN WITH DUCTWORK.
DISCHARGED OPENING SIZE
OSECTION A — A
SCALE: vr = 1' — ow
LEGAL DESCRIPTION
LOT D CITY OF TUKWILA SHORT PLAT NO L-94-0055 REC NO 9512269001 SD SHORT PLAT DAF:
PORTION OF GOVT LOT 1 STR 35-23-04 & OF GOVT LOT 1 STR 36-23-04 DAF - BEG AT NE
COR OF GOVT LOT 1 SD SEC 35 TH N 87-44-08 W ALG N LN SD GOVT LOT 1 SEC 35 DIST
OF 166.47 FT TH S 01-51-39 W 83.55 FT TO TPOB TH S 88-08-21 E 693.46 FT TO WLY
MGN JAMES CHRISTENSON RD TH S 07-32-21 W 51.98 FT TH S 10-58-39 E 253.52 FT TH S
09-54-21 W 457.25 FT TH S 07-00-39 E 444.05 FT TO N LN OF S 36.00 FT OF GOVT LOT 1
SD SEC 36 TH N 88-46-19 W ALG SD LN & WLY EXTENSION 1110F 579.62 FT TH ALG CRV TO
RIGHT CENTER OF WHICH BEARS N 01-13-41 E RADIUS OF 243.26 FT ARC DIST OF 166.17 FT
THRU C/A OF 39-08-19 TH ALG CRV TO RIGHT CENTER OF WHICH BEARS N 74-24-58 E
RADIUS OF 359.27 FT ARC DIST OF 109.38 FT THRU C/A OF 17-26-41 TH N 01-51-39 E
1041.08 FT TO TPOB LESS PORTION IF ANY LY WITHIN S 180TH ST AS CONVEYED TO CITY OF
TUKWILA BY DEEDS REC NOS 6375443 & 6375444 LESS W 27 FT SD SP (DESIGNATED AS
"RAILROAD EASEMENT. ON FACE OF SP) - BEING OPERATING R/VI FOR UNION PACIFIC RAILROAD
TAX PARCEL NUMBER: 362304-9107
BUILDING INFORMATION
ZONING: TUC
CONSTRUCTION TYPE: MASONRY (SPRINKLER)
OCCUPANCY TYPE: INDUSTRIAL (GEN PURPOSE)
.__
CODE FVIEl INL i'UL , E FOR _
APPPOVED
Auu 13 2010
City Tc4 -
BUILDING i SION
OWNER
COSTCO WHOLESALE CORP
VICINITY MAP
Bls;rd
rt' Dr
- -
Mad 01'
Triland EST -:-;•1'
ale Parlt0
Costco es
eikr
Sti
2nci
I
1
COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS
RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS
OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE ENERGEY CODE (WSEC) SECTION 1416.1 (2006 EDMON)
AN OPERATION MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC
SECTION 1416.2.4.2 (2006 EDMON)
ALL HVAC SYSTEMS SHAU. BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER
PER WSEC SECTION 1416.2.2. (2006 EDMON)
HVAC CONTROL SYSTEM SHALL BE TESTED, CALJBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE
TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS , AND COMPLETE
REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2 AND 1416.2.5.
(2006 EDMON)
SEPARATE PERMIT
REQUIRED FOR:
Mebbanical
al Electrical
at Plumbing
siI Gas Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
FILE COPY
Permit No. AAiD--1 .0)
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Cokand conditions is acknowledgvi
By\--
Date:. *IA
City Of Tlikwila
BUILDING DIVISION
j
HVAC FLOOR PLAN
SCALE: 1/4' = 1' - 0"
(E)
F
ABBREVIATIONS
ABV.
A.D.
A.P.
AH
BF
BOT
CIP
CLG
CD
CG
CTG
CONC.
CONN.
CFM
DIFF.
DIA.
DN
DWG.
DB
EA.
ENT.
EAT
EWT
EQUIP
EXH
ESP
RR
Fr.
FPM
FUT.
GALV.
GR.
HWG
HWTG
Hr.
HP
HWS
HWR
ABOVE
ACCESS DOOR
ACCESS PANEL
ABOVE FINISHED FLOOR
AIR HANDUNG UNIT
BELOW FLOOR
BOTTOM
CAST IN PLACE
CEILING
CEILING DIFFUSER
CEILING GRILLE
CEIUNG TRANSFER GRILLE
CONCRETE
CONNECTION
CUBIC FEET PER MINUTE
DIFFUSER
DIAMETER
DOWN
DRAWING
DRY BULB
EACH
ENTERING
ENTERING AIR TEMPERATURE
ENTERING WATER TEMPERATURE
EQUIPMENT
EXHAUST
EXTERNAL STATIC PRESSURE
FLOOR
FOOT or FEET
FEET PER MINUTE
FUTURE
GALVANIZE
GRILLE
HIGH WALL GRILLE
HIGH WALL TRANSFER GRILLE
HEIGHT
HORSEPOWER
HOT WATER SUPPLY
HOT WATER RETURN
ID INSIDE DIAMETER/DIMENSION
IE INVERT ELEVATION
IN. WG INCHES W.G.
UN. DIFF. LINEAR DIFFUSER
UN. FT. LINEAR FEET/FOOT
LWG LOW WALL GRILLE
LWR LOW WALL REGISTER
MAX. MAXIMUM
MBH 1000 BRITISH THERMAL UNITS
MIN. MINIMUM
MOT. DPR. MOTORIZED DAMPER
M•D MOUNTED
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
OSA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OD OUTSIDE DIAMETER/DIMENSION
PCF POUNDS PR CUBIC FOOT
POC POINT OF CONNECTION
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
RPBP REDUCED PRESSURE BACKFLOW PREVENTOR
RFA RELIEF AIR
REG. REGISTER
REQ'D REQUIRED
RA RETURN AIR
SQ. FT. SQUARE FEET
SA SUPPLY AIR
S.L SOUND LINED
TDH TOTAL DYNAMIC HEAD
TG 'TRANSFER GRILLE
TOT TOTAL
TYP TYPICAL
VTR VENT THROUGH ROOF
WB WET BULB
WG WATER GAUGE
W/ WITH
W/0 WITHOUT
DUCTWORK — LEGEND
0
0®
0
0
R - 100
S - 100
E - 100
141331
— — — SLSM
FC
SFD
AIR FLOW DIRECTION
SUPPLY OR OSA DUCT SECTION UP OR TOWARD
ROUND, RECTANGULAR
RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD
ROUND, RECTANGULAR
SUPPLY OR OSA DUCT SECTION DOWN OR AWAY
ROUND, RECTANGULAR
RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY
ROUND, RECTANGULAR
ROUND DUCT SYMBOL
RETURN AIR; NUMBER INDICATES CFM QUANTITY
SUPPLY AIR; NUMBER INDICATES CFM QUANTITY
EXHAUST AIR; NUMBER INDICATES CFM QUANTITY
SOUND UNED SHEET METAL
FLEXIBLE EQUIPMENT CONNECTION
SMOKE/FIRE DAMPER
FIRE DAMPER
VOLUME DAMPER
MOTORIZED DAMPER
TURNING VANES
ROUND TO ROUND 45' RUNG
SQUARE TO SQUARE 45' RUING
SQUARE TO ROUND 45 FITTING
VD J MIN. 3' 45• FITTING FOR DUCTWORK
1
GENERAL — LEGEND
NEW EQUIPMENT, DUCTWORK, AND GRILLES
EXISTING EQUIPMENT, DUCTWORK, AND GRILLES
-40---- DETAIL OR DIAGRAM NUMBER
SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN
0•11---- SECTION LETTER
-8/4--- SHEET NUMBER WHERE SECTION SHOWN
C2 1, REVISION CLOUD & CHRONOLOGICAL NUMBER
—1
L_ _J
DETAIL REFERENCE OUTUNE
KEY PLAN
COPYRIGHT NOTICE
THIS LAYOUT/DESIGN IS AN
UNPUBLISHED WORK, AND
MERIT MECHANICAL HEREBY
RESERVES ITS COMMON LAW
RIGHT, PURSUANT TO TITLE
17 SECTION 2 OF THE USA
CODE TO PREVENT ANY
UNAUTHORIZED COPYING,
PUBLICATION OR USE OF
THIS DESIGN, AND TO OBTAIN
DAMAGES THEREFORE.
441 COSTCO DRIVE
TUKWILA WA, 98188
MERIT MECHANICAL INC.
9630 153RD AVENUE NE
P.O. BOX 2109
REDMOND, WA 98073-2109
(425) 883-9224
FAX (425) 867-0962
LICENSE: MERITMI163CM
REVISIONS
1. ISSUED FOR PERMIT 07-30-10
RECEIVED
AUG 04 2010
PERMIT CENTER
DESIGNED
VTD
CHECKED
AEA
DATE
07-14
JOB NUMBER
810333
SHEET TITLE
HVAC PLAN &
SCHEDULES
SHEET NUMBER
M0.1
1-0E-1