Loading...
HomeMy WebLinkAboutPermit M10-108 - COSTCOCOSTCO 441 COSTCO DR M10 -108 J��I I L;4 x,1,, � sy O 6 E City Qftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: Address: 3623049107 441 COSTCO DR TUKW Project Name: COSTCO Permit Number: M10 -108 Issue Date: 08/23/2010 Permit Expires On: 02/19/2011 Owner: Name: Address: Contact Person: Name: Address: Email: COSTCO WHOLESALE CORP PROPERTY TAX DEPT 190 , 999 LAKE DR 98027 MICHAEL ATWOOD 9630 153 AV NE , REDMOND WA 98052 MATW OOD @MERITMECHANICAL. C OM Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: 425 883 -9224 Phone: 425 883 -9224 Expiration Date: 06/01/2011 DESCRIPTION OF WORK: INSTALL (1) EXHAUST FAN WITH DUCT FOR INDOOR SAND BLASTER. Value of Mechanical: $2,000.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signatur I hereby certify that I have read a governing this work will be comp Fees Collected: $209.63 International Mechanical Code Edition: 2009 Date: J ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p construction or the performance of work. e to give authority to violate or cancel the provisions of any other state or local laws regulating I • m authorized to sign and obtain this mechanical permit. Signature: Print Name: ILIOSI kr1,1411) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 1/7.3 fret() doc: IMC -4/10 M10 -108 Printed: 08 -23 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 3623049107 Address: 441 COSTCO DR TUKW Suite No: Tenant: COSTCO PERMIT CONDITIONS Permit Number: M10 -108 Status: ISSUED Applied Date: 08/04/2010 Issue Date: 08/23/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10 -108 Printed: 08 -23 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: hap://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any construction or the performance of work. Signature: Print Name: M I C.I} -4-{; L 1-7Q01717 Date: 0/24/0 of law and ordinances governing other work or local laws regulating doc: Cond -10/06 M10 -108 Printed: 08 -23 -2010 CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Project No, (forrffice use only) " MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 441 Costco Drive Tenant Name: Costo Property Owners Name: Costco Wholesale Mailing Address: 999 Lake Drive King Co Assessor's Tax No.: 3623049107 Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No Issaquah WA 98027 City State Zip CONTACT PERS+ your permi tidy to be Name: Michael Atwood Day Telephone: (425) 883 -9224 Mailing Address: 9630 153rd Ave NE Redmond WA 98052 City Fax Number: E -Mail Address: matwood @meritmechanical.com State (425) 867 -0962 Zip MEC.H TOR INFORMATION Company Name: Merit Mechanical, Inc. Mailing Address: 9630 153rd Ave NE Contact Person: Redmond WA 98052 Michael Atwood E -Mail Address: matwood @meritmechanical.com City State Zip Day Telephone: (425) 883 -9224 Fax Number: (425) 867 -0962 Contractor Registration Number: MERITMI163CM Expiration Date: 06/01/2011 ARCHITECT OF RECORD - All piat ped by. Arc Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD Inns must be we stamped by Engineer Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: A Applications \Emus- Applications On Line \2009 Applications VI -2009 - Mechanical Permit Application. doe Revised: 1 -2009 bh State Zip Page 1of2 Valuation of Project (contractor's bid price): $ 2,000 Scope of Work (please provide detailed information): Install 1 exhaust fan with duct. Fat NS �I )7$1 Q/ /�� T� Use: Residential: New Commercial: New Fuel Type: Electric ❑ to Replacement Replacement Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type Qty Boiler/Compressoi' Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 1 Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator— Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNER 0 UTHORIZED AG T: Signature: Print Name: Michael Atwood Mailing Address: 9630 153rd Ave. NE Date: 08/04/2010 Day Telephone: (425) 883 -9224 Redmond WA 98052 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: g —�--c a ,- -1"+— < < li:AApplications\Fonns- Applications On Line \2009 Applications VI -2009 - Mechanical Permit Application.doe Revised: 1 -2009 bit Page 2 of 2 • • City of Tukwila Department of Coinfminity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http. //www.ci.tukwila.wa.us Parcel No.: 3623049107 Address: 441 COSTCO DR TUKW Suite No: Applicant: COSTCO RECEIPT Permit Number: M10 -108 Status: PENDING Applied Date: 08/04/2010 Issue Date: Receipt No.: R10 -01487 Payment Amount: $209.63 Initials: WER Payment Date: 08/04/2010 10:16 AM User ID: 1655 Balance: $0.00 Payee: MERIT MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 24280 209.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 167.70 000.345.830 41.93 Total: $209.63 PAYMENT RFCEIVED doc: Receipt -06 Printed: 08 -04 -2010 INSPECTION RECORD Retain a copy with permit INSPEC • NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431=2451 Project '—• • Typere Inspetti n: Address. it 60S77---O .34., Date Called: I Sped I I s ructiOns: Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections-required prior to approvaI.-. MMENTS: 14> ; Dat ECTION FEE REQUIRED. rior to-n t inspection, fee must be t 6300 Southcenter Blvd/. S ite 100. C ll to schedule reinspection. • • • • PE 1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -108 PROJECT NAME: COSTCO SITE ADDRESS: 441 COSTCO DR X Original Plan Submittal Response to Incomplete Letter # DATE: 08 -04 -10 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Fp* r �o�' ull Ing Division gm Public Works n Am AO- 9 -s� -ro ire Prevention Structural ❑ Planning Division Permit Coordinator at DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: [x] Incomplete DUE DATE: 08-05 -10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09 -02 -10 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MERIT MECHANICAL INC UBI No. 600517946 Phone 4258839224 Status Active Address Po Box 2109 License No. MERITMI163CM Suite /Apt. License Type Construction Contractor City Redmond Effective Date 2/14/1984 State WA Expiration Date 6/1/2011 Zip 980732109 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUTOMMC044QH AUTOMATED MECH CONTROLS INC Construction Contractor General Unused 11/8/1996 6/1/2010 Expired Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V President 02/14/1984 Bond Amount KIRKWOOD, JOAN M Secretary 02/27/2006 08358695 FRICKBERG, WILLIAM MICHAEL Vice President 02/27/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 FIDELITY Et DEPOSIT CO OF MD 08358695 02/01/2010 Until Cancelled $12,000.0001 /20 /2010 9 ARCH INS CO SU1041124 02/01/2009 Until Cancelled 02/01/2010 $12,000.0001 /12/2009 8 TRAVELERS CAS SURETY CO 081S103546895BCM 07/22/2001 Until Cancelled 02/01/2009 $12,000.0003/07 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 25 CEOXINGTONINS 049159165 11/01/2009 11/01/2010 $2,000,000.0011 /02/2009 24 CEOXINGTONINS 004052434 11/01/2008 11/01/2009 $2,000,000.00 11/04/2008 23 ACE AMERICAN HD0G23734941 03/03/2008 03/03/2009 $2,000,000.0003 /10/2008 22 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2007 11/01/2008 $1,000,000.00 10/31/2007 21 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2005 11/01/2007 $1,000,000.00 10/18/2006 20 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2004 11/01/2005 $1,000,000.0011 /01/2004 19 ST PAUL FIRE MARINE KC08400069 11/01/2003 11/01/2005 $1,000,000.00 10/27/2004 https://fortress.wa.gov/lni/bbip/Print. aspx 08/23/2010 EXHAUST FAN SCHEDULE SYMBOL MAKE & MODEL DESCRIPTION CFM ESP RPM SOUND RATING ELECTRICAL WEIGHT NOTES SONES 0 DIST. WATTS V/PH/HZ EF-1 FANTECH FKD12 INUNE EXHAUST FAN 1050 0.75 2900 23 531 115-1-60 21 1, 2 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR BETTER OR EQUAL MANUFACTURER. 2. MANUAL SWITCH, SPEED CONTROL GENERAL NOTES 1. FIELD VERIFY UNIT LOCATIONS, DROPS, AND POSMONS. 2. MAINTAIN 10'-0" MINIMUM DISTANCE BETWEEN O.S.A. INLETS AND PLUMBING WASTE VENTS, EXHAUST, AND COMBUSTION AIR OURETS. 3. INSULATE DUCT PER W.S.E.C. 4. SEAL ALL TRANSVERSE DUCT JOINTS. 5. ALL UNE VOLTAGE BY ELECTRICIAN. 6. HVAC SYSTEM IS DESIGNED PER 2006 WSEC, IBC, AND INC. EXISTING NEPA FILTER SCOPE OF WORK 1. INSTALL 1 EXHAUST FAN WITH DUCTWORK. DISCHARGED OPENING SIZE OSECTION A — A SCALE: vr = 1' — ow LEGAL DESCRIPTION LOT D CITY OF TUKWILA SHORT PLAT NO L-94-0055 REC NO 9512269001 SD SHORT PLAT DAF: PORTION OF GOVT LOT 1 STR 35-23-04 & OF GOVT LOT 1 STR 36-23-04 DAF - BEG AT NE COR OF GOVT LOT 1 SD SEC 35 TH N 87-44-08 W ALG N LN SD GOVT LOT 1 SEC 35 DIST OF 166.47 FT TH S 01-51-39 W 83.55 FT TO TPOB TH S 88-08-21 E 693.46 FT TO WLY MGN JAMES CHRISTENSON RD TH S 07-32-21 W 51.98 FT TH S 10-58-39 E 253.52 FT TH S 09-54-21 W 457.25 FT TH S 07-00-39 E 444.05 FT TO N LN OF S 36.00 FT OF GOVT LOT 1 SD SEC 36 TH N 88-46-19 W ALG SD LN & WLY EXTENSION 1110F 579.62 FT TH ALG CRV TO RIGHT CENTER OF WHICH BEARS N 01-13-41 E RADIUS OF 243.26 FT ARC DIST OF 166.17 FT THRU C/A OF 39-08-19 TH ALG CRV TO RIGHT CENTER OF WHICH BEARS N 74-24-58 E RADIUS OF 359.27 FT ARC DIST OF 109.38 FT THRU C/A OF 17-26-41 TH N 01-51-39 E 1041.08 FT TO TPOB LESS PORTION IF ANY LY WITHIN S 180TH ST AS CONVEYED TO CITY OF TUKWILA BY DEEDS REC NOS 6375443 & 6375444 LESS W 27 FT SD SP (DESIGNATED AS "RAILROAD EASEMENT. ON FACE OF SP) - BEING OPERATING R/VI FOR UNION PACIFIC RAILROAD TAX PARCEL NUMBER: 362304-9107 BUILDING INFORMATION ZONING: TUC CONSTRUCTION TYPE: MASONRY (SPRINKLER) OCCUPANCY TYPE: INDUSTRIAL (GEN PURPOSE) .__ CODE FVIEl INL i'UL , E FOR _ APPPOVED Auu 13 2010 City Tc4 - BUILDING i SION OWNER COSTCO WHOLESALE CORP VICINITY MAP Bls;rd rt' Dr - - Mad 01' Triland EST -:-;•1' ale Parlt0 Costco es eikr Sti 2nci I 1 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE ENERGEY CODE (WSEC) SECTION 1416.1 (2006 EDMON) AN OPERATION MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.2 (2006 EDMON) ALL HVAC SYSTEMS SHAU. BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 1416.2.2. (2006 EDMON) HVAC CONTROL SYSTEM SHALL BE TESTED, CALJBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS , AND COMPLETE REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2 AND 1416.2.5. (2006 EDMON) SEPARATE PERMIT REQUIRED FOR: Mebbanical al Electrical at Plumbing siI Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. AAiD--1 .0) Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cokand conditions is acknowledgvi By\-- Date:. *IA City Of Tlikwila BUILDING DIVISION j HVAC FLOOR PLAN SCALE: 1/4' = 1' - 0" (E) F ABBREVIATIONS ABV. A.D. A.P. AH BF BOT CIP CLG CD CG CTG CONC. CONN. CFM DIFF. DIA. DN DWG. DB EA. ENT. EAT EWT EQUIP EXH ESP RR Fr. FPM FUT. GALV. GR. HWG HWTG Hr. HP HWS HWR ABOVE ACCESS DOOR ACCESS PANEL ABOVE FINISHED FLOOR AIR HANDUNG UNIT BELOW FLOOR BOTTOM CAST IN PLACE CEILING CEILING DIFFUSER CEILING GRILLE CEIUNG TRANSFER GRILLE CONCRETE CONNECTION CUBIC FEET PER MINUTE DIFFUSER DIAMETER DOWN DRAWING DRY BULB EACH ENTERING ENTERING AIR TEMPERATURE ENTERING WATER TEMPERATURE EQUIPMENT EXHAUST EXTERNAL STATIC PRESSURE FLOOR FOOT or FEET FEET PER MINUTE FUTURE GALVANIZE GRILLE HIGH WALL GRILLE HIGH WALL TRANSFER GRILLE HEIGHT HORSEPOWER HOT WATER SUPPLY HOT WATER RETURN ID INSIDE DIAMETER/DIMENSION IE INVERT ELEVATION IN. WG INCHES W.G. UN. DIFF. LINEAR DIFFUSER UN. FT. LINEAR FEET/FOOT LWG LOW WALL GRILLE LWR LOW WALL REGISTER MAX. MAXIMUM MBH 1000 BRITISH THERMAL UNITS MIN. MINIMUM MOT. DPR. MOTORIZED DAMPER M•D MOUNTED N.C. NORMALLY CLOSED N.O. NORMALLY OPEN OSA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER/DIMENSION PCF POUNDS PR CUBIC FOOT POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE RPBP REDUCED PRESSURE BACKFLOW PREVENTOR RFA RELIEF AIR REG. REGISTER REQ'D REQUIRED RA RETURN AIR SQ. FT. SQUARE FEET SA SUPPLY AIR S.L SOUND LINED TDH TOTAL DYNAMIC HEAD TG 'TRANSFER GRILLE TOT TOTAL TYP TYPICAL VTR VENT THROUGH ROOF WB WET BULB WG WATER GAUGE W/ WITH W/0 WITHOUT DUCTWORK — LEGEND 0 0® 0 0 R - 100 S - 100 E - 100 141331 — — — SLSM FC SFD AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR ROUND DUCT SYMBOL RETURN AIR; NUMBER INDICATES CFM QUANTITY SUPPLY AIR; NUMBER INDICATES CFM QUANTITY EXHAUST AIR; NUMBER INDICATES CFM QUANTITY SOUND UNED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION SMOKE/FIRE DAMPER FIRE DAMPER VOLUME DAMPER MOTORIZED DAMPER TURNING VANES ROUND TO ROUND 45' RUNG SQUARE TO SQUARE 45' RUING SQUARE TO ROUND 45 FITTING VD J MIN. 3' 45• FITTING FOR DUCTWORK 1 GENERAL — LEGEND NEW EQUIPMENT, DUCTWORK, AND GRILLES EXISTING EQUIPMENT, DUCTWORK, AND GRILLES -40---- DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN 0•11---- SECTION LETTER -8/4--- SHEET NUMBER WHERE SECTION SHOWN C2 1, REVISION CLOUD & CHRONOLOGICAL NUMBER —1 L_ _J DETAIL REFERENCE OUTUNE KEY PLAN COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 441 COSTCO DRIVE TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073-2109 (425) 883-9224 FAX (425) 867-0962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERMIT 07-30-10 RECEIVED AUG 04 2010 PERMIT CENTER DESIGNED VTD CHECKED AEA DATE 07-14 JOB NUMBER 810333 SHEET TITLE HVAC PLAN & SCHEDULES SHEET NUMBER M0.1 1-0E-1