Loading...
HomeMy WebLinkAboutPermit M10-112 - BOEING #11-14BOEING #11 -14 2925 S 112 ST EXPIRED 03 -27 -11 M10 -112 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: Address: 0923049155 2925 S 112 ST TUKW Project Name: BOEING #11 -14 Permit Number: M10 -112 Issue Date: 09/01/2010 Permit Expires On: 02/28/2011 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 MARK CLEMENT PO BOX 3707 MC 1W -10 , SEATTLE WA 98124 MARK. D .CLEMENT @BOEING . C O M Phone: 206 - 617 -2944 BOEING COMPANY, THE Phone: 312 544 -2535 Address: 100 N RIVERSIDE, M/C 5003 -4027 , CHICAGO IL 60606 -1596 Contractor License No: BOEINC *294ML Expiration Date: 01/14/2011 DESCRIPTION OF WORK: REPLACE EXISTING CEILING MOUNTED SPLIT SYSTEM AIR LOCATED IN GARAGE LEVEL ADJACENT TO UPS ELECTRONICS ROOM WITH NEW UNIT. CURRENT SYSTEM USES R22 WHICH IS BEING RESTRICTED AS A GREEN HOUSE GAS. INSTALL NEW UNIT AHU -1B, CARRIER MODEL 40RUA AIR HANDLER WITH CONDENSER CARRIER MODEL 38 AUZ AND NEW R410 TUBING SYSTEM Value of Mechanical: $75,000.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $1,053.31 International Mechanical Code Edition: 2009 Date: U 64[0 I hereby certify that I have read and xan \ined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie wit whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: ! ( ( 1 1 Print Name: M Av K C1 t, M e a A' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -112 Printed: 09 -01 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 0923049155 Address: 2925 S 112 ST TUKW Suite No: Tenant: BOEING #11 -14 PERMIT CONDITIONS Permit Number: M10 -112 Status: ISSUED Applied Date: 08/09/2010 Issue Date: 09/01/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Thkwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the doc: Cond -10/06 M10-112 Printed: 09 -01 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 21: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10-112 Printed: 09 -01 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http. / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: r\,9 Date: doc: Cond -10/06 M10 -112 Printed: 09 -01 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Permit No. VI, tV— 1 ( Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION ��j15 S 1 IBS 1 Site Address: 1 9-T-ttfc Tenant Name: The Boeing Company Property Owners Name: The Boeing Company King Co Assessor's Tax No.: 0923049155 Number: New Tenant: Mailing Address: PO Box 3707, Mail Code 1W-10 Seattle Floor: 1d1 dyC ❑ Yes La „No WA 98124 Zip City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Mark Clement Mailing Address: PO Box 3707, Mail Code 1W-10 E -Mail Address: mark.d.clement @ boeing.com Day Telephone: (206) 617 -2944 Seattle WA 98124 City State Fax Number: (206) 544 -2531 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: The Boeing Company, General Construction Unit Mailing Address: PO Box 3707 Mail Code 1W-10 Contact Person: Erik Hajek E -Mail Address: eric.a.hajek @boeing.com Contractor Registration Number: BOEINC *294ML City State Zip Day Telephone: (206) 766 -1474 Fax Number: (206) 544 -2531 Expiration Date: 01/14/2011 ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: The Boeing Company, Shared Service, Plant 2 Plant Engineering Mailing Address: PO Box 3707 Mail Code 1W-10 Contact Person: Fay Weaver WA 98124 E -Mail Address: fay.j.weaver @boeing.com City State Zip Day Telephone: (206) 662 -2936 Fax Number: (206) 544 -2531 ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: The Boeing Company, Shared Service, Plant 2 Plant Engineering Mailing Address: PO Box 3707 Mail Code 1W-10 Contact Person: Wyman Henckel E -Mail Address: wyman.d.henckel @ boeing.com WA 98124 11: Applications. romis- Applications Uu Line 2010 Application. 7 -2010 - \lechanical remit AppliL tion.tloc Revised: 7 -2010 bh City State Day Telephone: (206) 662 -2219 Fax Number: (206) 544 -2531 Zip Page 1 of 2 • • Valuation of project (contractor's bid price): $ 75,000 Scope of work (please provide detailed information): Summary: Replace existing ceiling mounted split system air located in garage level adjacent to UPS Electronics Room with new unit. Current system uses R22 which is being restricted as an green house gas. Install new unit AHU -1 B, Carrier Model 40RUA AIR HANDLER with condenser CARRIER MODEL 38AUZ and new R410 tubing system Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfin fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30-50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp/1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic ethe meical equipp menchant air handling unit <10,000 cfin 1 incinerator — comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the pennit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER i / UTHORIZED Signature: ova Print Name: r'' ' ' NY K C, e reNfrvi , eOC; 14y Mailing Address: @.O . Vb1, -5101 9 /I, Date: Day Telephone: 204 CI 7 ._2 r + Z'1 Zip WA City State IDate Application Accepted: Date Application Expires: g.Chl I Staff Initials: ( 11. apphcationa.Forms- Applicetiona On Liu.. 2010 Appl ..,buns 7 -2010 • •\IcLhuuical Pawn Appli. alio] ∎aloe Res iscd: 7 -2010 bh Page 2 of 2 J,w� ►�A wq City oPlrukwila 0 3 2 Department of Community Development:_ _-°-- 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: M10 -112 Address: 11201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 08/09/2010 Applicant: BOEING #11 -14 Issue Date: Receipt No.: R10 -01530 Payment Amount: $1,053.31 Initials: WER Payment Date: 08/09/2010 02:51 PM User ID: 1655 Balance: $0.00 Payee: BOEING TRUST ACCOUNT 000.239.103 TRANSACTION LIST: Type Method Descriptio Amount Payment Other Authorization No. ACCOUNT ITEM LIST: Description 1,053.31 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 842.65 000.345.830 210.66 Total: $1,053.31 PAY E •T EGEIVED doe: Receipt -06 Printed: 08 -09 -2010 Aki to_ • INSPECTION RECORD Retain a copy with permit INS CTION NO. PERMIT NO. _ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 GXl Project: Type f Inspection: • ; 3. A3dress. Date Called. Special Instructions: Date Wanted: Requester: Phone No: Approved per applicable codes. - • El Corrections required prior to approval. COMMENTS: -- pp �� �L-/l -6; —,'- • -cl'J? c.(V /-7-4(4"1- ('mil t e_.-7 A_ee4! C---D ...:Sv_�,.- .J2 -= t��1- _ L>'� l .�S_ ( , J r. i� ee -e - i � _� (e s' <�('Ai=fP S e � , / f ' /Le__ a e� - _` t- d i * c j, taid C Sdt-L a k-e S (4-,t7"-- i efibt rA A, , rn � a�.n f�� A (.�! c I J �'l �J t. REINSPECTION FEE REQUIR . Pnor to next inspection. fee must be; paid at 6300 Southcenter Blvd.. Suite 100: Call to schedule reinspection: r . SHINGTON 3290 146th PI. S.E. / Bellevue, Wash 98007 (425) 562 -1150 (425) 562 -5123 fax FILE COPY pr8r # No. SUBMITTAL EQ;i �MENT G 7 MANUFACTURER TAG(S) DATE REPRESENTITIVE SPLIT SYSTEM COOLING SYSTEM CARRIER CORPORATION SS September 24, 2009 tMatthew Adkins • PROJECT BOEING DUWAMISH — BUILDING 11 -14 LOCATION Seattle, Washington .' Q -. OWNER Boeing Company Included with the • • • split system: 40RU Indoor Air Handler 38AU Outdoor Cooling Only Condensing Unit Low Ambient Controls • Winter Start Package • Overhead Suspension Brackets • Enthalpy Controlled Economizer • Factory Start-up • 1s` year Parts and Labor Warranty , ti -O —REVIEWED FOR 5'J0 COMPLIANCE APPROVED AUG 2 6 2010 Cityof Tukwila BUILDING DIVI,SIGN fez RECEIVED AUG 09 2010 PERMIT CENTER SUBMITTAL Project - Untitled3 Date f e-,,neral Contractor 1/ Mechanics Contractor L' ,O Mechanical Engine r MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 3 8 A U Z A 1 4 A 0 G 6 0 A 0 A 0 Model Type 38AU = Carrier Condensing Unit Puron® R -410A Refrigerant Type of Coil Z = Single Circuit, NC Scroll Compressor �J pigerant Options A = None B = Loh• Ambient Nominal Tonnag i ; 07 = 6 Tons 08 = 7.5 Tons 12 = 10 Tons 14 = 12.5 Tons Factory Assigned A = Default Factory Assigned 0 = Default /3 ENERGY STAR PARTNER This product has been designed and manufactured to meet Energy Stara criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer's refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment lie. Brand / Packaging 0 = Standard 1 = LTL Electrical Options A = None C = Non —Fused Disconnect Service Options 0 = None 1 = Un— powered Convenience Outlet 2 = Powered Convenience Outlet Factory Assigned A = Default Base Unit Controls 0 = Electro— Mechanical Controls Design Rev — = Catalog Model Number Voltage 1 = 575/3/60 5 = 208/230/3/60 6 = 460/3/60 n Coil Options = Al /AI (A/C only) E —Coat Al /AI T- 4Q /Al with louvered hail guard W = Ems- Chat Al /AI with louvered hail guard �ASH�RA� 0 LJ COMPLIANT tzo 6, Puron ' 7 itw emeamrrernaIN sound refrigwant ARI* CAPACITY RATINGS UNIT COOLING STAGES NOM. CAPACITY (TONS) NET COOLING CAPACITY (MBH) TOTAL POWER (KW) EER IPLV 38AUZ07 1 6 71.0 6.1 11.20 N/A 38AUZ08 1 7.5 92.0 8.2 11.20 N/A 38AUZ12 1 10 117.0 10.3 11.20 N/A 38AUZ14 1 12.5 148.0 13.5 11.00 N/A * Above ratings are with matching size air handling unit. 61 SO iD POWER LEVELS, dB UNIT' OOLING S/TAGES OUTDOOR SOUND (dB) A- WEIGHTED 63 125 250 500 1000 2000 4000 8000 38AUZ07 j 11 82 90.1 82.6 81.0 79.4 77.0 73.0 70.4 66.7 38AUZ08 :1'7 82 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 38AUZ12 1 S7j- 83 91.2 86.4 81.9 81.0 78.3 73.9 71.4 67.3 38AUZ14 1 ' L 82 90.1 82.6 81.0 79.4 77.0 73.0 70.4 66.7 LEGEND dB = Decibel NOTE: Outdoor sound data is me ure in accordance with ARI standard 270 -2008. .,r 4 Project: -Untitled3 Prepared By: Table Of Contents 09/24/2009 02:07PM SS-1 Unit Report Performance Summary Acoustic Summary Certified Drawing Guita,Specifications HVAC-174:ide Specifications S.‘r Unit Featit;e4 Sheet •COMMERCIAL SPLIT SYSTEMS itNUy7. 6 TO 12.5 TON . . AIR-COOLED CONDENSING UNITS with PURON® REFRIGERANT 40RUA;6 TO 10 TON CHASSIS SHOWN STANDARD FE1:1)RES Certified to IS6900„1:2000 <77 kJ/ <. 4, 3 4 6 8 9 11 14 17 17 17 17 18 18 18 Commercial Split Systems Builder 1.13 Page 2 of 18 Project: - Untitled3 Prepared By: SS -1 09/24/2009 02:07PM SS -1 7� 7 Tag Cover Sheet Unit Report Performance Report P\ Acoustic Summary Certified Drawing 'wide Specification Ui Feature Sheet f/ 6) L) Commercial Split Systems Builder 1.13 Page 3 of 18 Project: - Untitled3 Prepared By: Unit Report For SS -1 09/24/2009 02:07PM ' %4 Outdoor Unit Parameters< , Unit Quantity: Unit Model:.. Unit Size: Voltage: No. of DX Circuits: System Parameter System Quantity:. ........ Refrigerant Type:.. Compressor Quantity: Compressor Type: Std. Capacity Steps:. Std. Min. Outdoor Temp(Cooling): No. of Outdoor fans: Outdoor Unit Dimensions and Weight Unit Length: Unit Width: Height: .. . .. Unit Shipping Weight: Unit Operating Weight:.. ... 1 38AUZ 12.5 Tons 460 -3 -60 PURO4` 1 Scroll 100 -20.0 °F 2 ... ... 1 V -Ph -Hz 4' 11.4" 3' 9.8" 4' 2.4" 480 lb 431 Ib Accessories and Installed Options Low ambient FIOP operation down to -20 F. Warranty Information Start-Up, First Unit for Outdoor Unit Complete Unit 1st Year Carrier CCS Labor for Outdoor Unit Complete Unit 1st Year Carrier CCS Labor for Outdoor Unit Start-Up, First Unit for Outdoor Unit Indoor Unit Parameters Unit Quantity:....... Unit Model:........ Unit Size:. .... No. of Splits: ........... Voltage:.. . 1 40RUA 15 Tons 1 460 -3 -60 V -Ph -Hz .In inor Unit Dimensions and Weight (.L Op. Length: .. 7' 5.0" U {it'Jidth:. 2' 4.2" Unit HIght:. . 4' 8.1" Unit Shi,51!ng Weight: 713 Ib Unit Opera`:inn Weight: ..... . . 713 Ib V� NOTE: Please see Warranty Catalog 808 -218 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity Base Unit - Outdoor 38AUZB14A0K6 -0A000 1 Base Unit E- Coated AI /AI 1 Low Ambient Controls 1 None 1 Base Unit - Indoor 40RUAA16A2A6 -0A0A0 1 Commercial Split Systems Builder 1.13 Page 4 of 18 Project: — Untitled3 Prepared By: Unit Report For SS -1 09/24/2009 02:07PM "l' ✓ Q 0.6 Commercial Split Systems Builder 1.13 Page 5 of 18 Base Unit Standard Motor / Medium Drive 1 None 1 Accessories "CRWINSTRO01A00 Winter Start Package Overhead Suspension Brackets 1 1 "-(? SUSPEN001A00 ClitgOOMZR002A00 Economizer - Enthalpy Controlled 1 "l' ✓ Q 0.6 Commercial Split Systems Builder 1.13 Page 5 of 18 Project: -Untitled3 Prepared By: Performance Summary For SS-1 09/24/2009 02:07PM System: System Quantity:.... . Alt!tude: Ectft--@, ARI Conditions:. ...... . LinkKipe Length: Suction4'41e Size: Liquid Line: 38AUZ014/40RUA016 1 0.0 ft NA 25.0 ft 1 3/8 in 5/8 in 7 Outdoor Unit Parameters Unit Quantity: • Unit Model: Unit Size: No. of DX Circuits: Voltage: . Clg Ent Air DB:. Indoor Unit External Static: Economizer Loss: Grille Loss. Plenum Loss: Acc. Heating Loss: Total Ext Static: 1 38AUZ 12.5 Tons 1 460-3-60 V-Ph-Hz „ 95.0 °F 0.60 in wg l'i?es, 0.09 in wg A:•_:, 0.00 i n wg .c.00 in wg .09 in wg •,in wg Outdoor Electrical Data Unit Voltage: 460-3-60 Unit#1 MCA: 24.0 Unit#1 MOCP: . 40.0 Total Compressor Power of Unit #1: NA Voltage Range Min: . 414 V Voltage Range Max: 506 V Compressor RLA: . 18.6 Compressor LRA 125 Compressor Quantity . ................. 1 Fan Motors Qty: . 2 Notice: Outdoor unit elect. data is based on 460-3-60 V-Ph-Hz Amps Amps Indoor Electrical Data Unit Voltage: 460-3-60 V-Ph-Hz Unit MCA: 6.0 Amps Unit MOCP: 15.0 Amps Notice: Indoor unit elect. data is based on 460-3-60 - Motor is rated for tri voltage 208/230/460-3-60V. Factory wired for 460-3-60 application. Acoustics Indoor Unit Parameters Unit Quantity: . Unit Model: Unit Size: Coil Rows:. No. of Splits: Voltage: Actual Airflow: Total Clg Cap.(Gross):.. . ... Sensible Clg Cap.(Gross): Ent Air DB: Ent Air WB: . Ent Enthalpy: Lvg Air DB: Lvg Air WB: Lvg Enthalpy: Coil Bypass Factor: Indoor Supply Fan ,,Indoor Unit External Static: rnomizer Loss: r . Loss: Pl;erm Loss: . Acc. 17.!Aiting Loss: Total Extptic: Fan Speed!. rs, Fan Power: Fan Motor Max!' Fan Motor FLA: Standard Motor and ,:viar'ium Static Drive Required. Accessories and Installed Optisons Low ambient FIOP operatiorG2 wn to -20 F. 0=1 Or:7 ; 1 40RUA 15 Tons 4 1 460-3-60 6000.0 162.6 136.9 80.0 67.0 31.44 58.9 58.6 25.42 NA V-Ph-Hz CFM MBH MBH °F °F BTU/lb °F °F BTU/lb 0.60 in wg 0.09 in wg 0.00 in wg 0.00 in wg 0.00 in wg 0.69 in wg 761 RPM 2.36 BHP 3.70 BHP 4.8 Amps Commercial Split Systems Builder 1.13 Page 6 of 18 Project: - Untitled3 Prepared By: Performance Summary For SS -1 09/24/2009 02:07PM Sound Power Levels, db re 10E -12 Watts Acoustic Notes: 1. 38AUZ07 -12 units are in accords 'i3e with ARI 270 -2008 Sound Rating of Unitary Equipment. 2. The sound data for all 38AUZ14 u Os re based on upon a limited amount of actual testing with the estimated sound power data being generated from this data in accor ariss�F. with ARI 370 -2001 for Large Outdoor Refrigerating and Air - Conditioning Equipment. 3. The indoor duct sound power data is est rated based on the ASHRAE calculation approach from the ASHRAE handbook 1987 HVAC Systems and Applications, Chapter 52.1r) 4. The acoustic center of the unit is located artt\i\ geometric center of the unit. 5. All estimated sound power levels, dB re 1 Pico v`a4 should not be guaranteed or certified as being the actual sound power levels. /c-) 40RUA016withS dCapacityCoil 0 - \ \ "N N-N\ Outdoor Unit (dB) Indoor Unit (dB,Ducted)- _4 A- WEia',ited Total Level 82.0 92.7 63Ht-d„K. 90.1 98.9 125Hz \401, 82.6 94.9 250Hz rn 81.0 90.9 500Hz `' - 79.4 91.9 1000Hz ' 7 77.0 85.9 2000Hz ' 7 73.0 83.9 4000Hz V,- 70.4 79.9 8000Hz 66.7 NA Sound Message ;Sound for AUZ014 Sound for RUA016 Acoustic Notes: 1. 38AUZ07 -12 units are in accords 'i3e with ARI 270 -2008 Sound Rating of Unitary Equipment. 2. The sound data for all 38AUZ14 u Os re based on upon a limited amount of actual testing with the estimated sound power data being generated from this data in accor ariss�F. with ARI 370 -2001 for Large Outdoor Refrigerating and Air - Conditioning Equipment. 3. The indoor duct sound power data is est rated based on the ASHRAE calculation approach from the ASHRAE handbook 1987 HVAC Systems and Applications, Chapter 52.1r) 4. The acoustic center of the unit is located artt\i\ geometric center of the unit. 5. All estimated sound power levels, dB re 1 Pico v`a4 should not be guaranteed or certified as being the actual sound power levels. /c-) 40RUA016withS dCapacityCoil 0 - \ \ "N N-N\ �`^ \ LJ \ -...\ \.T ` V eoor�n� �� / ",,,\\ N_ eN V-') -.',4) 8 70riPM \ `` .. ` ` --------------- �/ 2 \ p ' \ \ 70: P 5. BHP BFP i 50 HP \ \ 0 2 4 6 8 10 Airflow(CFM- thousands) RPM =761 BHP= 2.36MaximumRPM= 1200MaximumHP =7.50 SC- System Curve RP- RatedPoint MP- MinimumPoint 12 14 Commercial Split Systems Builder 1.13 Page 7 of 18 Project: - Untitled3 Prepared By: Acoustic Summary For SS -1 09/24/2009 02:07PM Outdoor Unit Parameters: Tag Name: SS -1 U.r,:t Model: 38AUZ Lit-Size: 12.5 Tons Syst rq Type: Dx Cooling Only Refrigi ra'.t Type:. _.. PURON CompresuF9uantity: 1 Compressop `type: Scroll i� 1 - Outdoor Unit Height Above Ground 2 - Horizontal Distance From Outdoor Unit to Receiver 3 - Receiver Height Above Ground Octave Band Center Frequency; 47,:1 31 63 125 250 500 1k 2k 4k 8k Total Sound Power at Unit Acoustic Centers, B NA 90.1 82.6 81.0 79.4 77.0 73.0 70.4 66.7 91.8 A- Weighted Sound Power, dBA '''Y, -. NA 63.8 66.5 72.4 76.2 77.0 74.2 71.4 65.6 82.0 Sound Pressure at specified distance in a irejr ield,dB NA 58.3 50.8 49.2 47.6 45.2 41.2 38.6 34.9 59.9 A- Weighted Sound Pressure Level, dBA NA 32.0 34.7 40.6 44.4 45.2 42.4 39.6 33.8 50.2 Notes r? 1 - Outdoor Unit Height Above Ground = 0.0 ft 2 - Horizontal Distance From Outdoor Unit to Receiver = 50.O.fft 3 - Receiver Height Above Ground = 0.0 ft Acoustic Notes: 1. 38AUZ07 -12 units are in accordance with ARI 270 -2008 Sound Rat of Unitary Equipment. 2. The sound data for all 38AUZ14 units are based on upon a limited aye f.5fi t of actual testing with the estimated sound power data being generated from this data in accordance with ARI 370 -2001 for Large Gu±foor Refrigerating and Air - Conditioning Equipment. 3. The indoor duct sound power data is estimated based on the ASHRAE cataltion approach from the ASHRAE handbook 1987 HVAC Systems and Applications, Chapter 52. 4. The acoustic center of the unit is located at the geometric center of the unit. 5. All estimated sound power levels, dB re 1 Pico watt should not be guaranteed or ce i i. d as being the actual sound power levels. ti Indoor Unit Parameters: Tag Name: SS -1 Unit Model:. 40RUA Unit Size: 15 Tons System Type: Dx Cooling Only External Static Pressure:.. 0.69 in wg Fan Speed: 761 RPM Fan BHP: . . 2.36 BHP Octave Band Center Frequency, Hz 31 63 125 250 500 1k 2k 4ki -8k Total Sound Power,dB NA 98.9 94.9 90.9 91.9 85.9 83.9 79.9 '-'yA 101.6 A- Weighted Sound Power, dBA NA 72.6 78.8 82.3 88.7 85.9 85.1 80.9 NW.-.92.7 Sound Pressure at specified distance in a free field,dB NA NA NA NA NA NA NA NA NA` 41JA A- Weighted Sound Pressure Level, dBA NA NA NA NA NA NA NA NA NA NA Notes: 1. The above estimated duct sound power levels are based upon the ASHRAE calculation approach from the ASHRAE 1987 HVAC Systems and Applications handbook, Chapter 52. 2. Since this data is calculated, these sound power levels may be different than the actual sound power levels. 3. The acoustic center of the units is located at the geometric center of the unit. Commercial Split Systems Builder 1.13 Page 8 of 18 Project: - Untitled3 Prepared By: <sax\ Certified Drawing for SS -1 09/24/2009 02:07PM UNIT ELECTRICAL CHARACTERISTICS STD. U IT T. .0 598X, A X®' '. •®' C0R ER D (28.61 CENTER OF GRAVITY 19.51 OMIT HEIGHT LBS. KG. LB S ' mumigagiml 1-3 /8 LBS. KG. (12.11 X T [34.91 2 H 38461.07 203/230 -3- 60_460 -3- 60,575-3.60 328 149 128 3640014 68 "maim (34.91 70 32 21 [533 -4] 19 (482.61 13 [330.2] 42 -3/8 [1076.01 38460.08 208/230 -3- 60,460 -3- 60,575-3 -60 353 160 138 I/O IF ® 65 28 76 35 11 1482 -61 23 1584.21 13 (330.2] 42 -316 [1076.01 38461-12 2081230-3-60,460 -8- 60,575 -3 -60 418 190 165 m, .3 30 78 35 90 41 23 (584.2] 20 1508.01 15 [381.0] 50 -3/8 [1279.21 38060 -14 208 /230 -3- 60,460 -3- 60,515 -3 -60 431 196 162 193 190 164 140 m m55� �'1'7m mm m�m 8• 111 mums um 38 ® m 95 123 151 97 130 41 56 68 44 59 18 (482.61 23 1584.21 15 1381.01 50 -3 /8 11279.21 38860 -12 208/230 -3- 60,460 -3- 60,575 -3 -60 499 505 444 485 226 229 201 220 20 20 23 20 (508.01 [508.01 1584.21 (508.01 23 24 26 24 1584.20 1609.61 (660.41 (609.6] 15 15 13 13 1331.01 1381.01 1330.21 [330.21 50-3/6 50 -3/8 42-3/8 11279.21 11279.21 11076.01 38850-14 208/230 -3- 60,460 - 3-60,515-3-60 30AU0-01 208/230 -3- 60,460 -3- 60,515 -3 -60 38650 -03 208/230-3-60,460 -3- 60,515 -3 -60 42 -3/8 (1016.01 38450 -12 208/230 -3- 60.460- 360,515 -3.60 527 239 151 m 141 64 m 141 64 21 (533.41 24 [609.6] 15 1381.01 50-3/8 [1279.21 OUTDOOR COIL REARVIEW 3 -3/4 (961 �IOUTDOOR COIL �] B ._41 - -� -111.1._. 6 -5/8 4 -5/8 ■ (1681 1116) 0 UNITED 4.0. 605 4606 TECHNOLOGIES nu6500, 44 CARRIER (0080 Tx 5 50:OXE01 15 151 41041114 05 801x1(1 C0118W5TT01 056 coNTINIS 5EWILL xNOT69050 8CLOSED ON OSLOWII1501 58410E OE C8X401A1I0X'S *1(1185 CONSENT. 588X155100 0' 16(01 05011X61 05 00(5 001 801511101E 4083 11X10 A[L[IiOXt[ W 8051 R0[T THIS SIDE ONLY FOR 38411114 S 3806014 59 -3/8 LECTRICAL DISCONNECT LOCATION 13-1/4 [3371 OPTIONAL FACTORY INSTALLED DISCONNECT 1 -3/8 134.51 POWER ENTRY WITH 50.0/58.0/65.0 NN 9.0. MORAL FACTORY INSTALLED CONVENIENCE OUILET LOCATION 1.3/4 144.51 GUAGE ACCESS I/O (22.21 FIELD NUT SERVICE PORT FORK TRUCK SLOTS - (4 SIDES/ LEFT SIDE VIEW TOP VIEW SUCTION CONNECTIONS (SEE CHART FOR SIZE) L10UID CONNECTION (SEE CHART FOR 6(000 OHNER rs� -7 -� // Vi SUCTION COKNECTIO (SEE CHART FOR SI2E1 \-1,h5 45 7/8 (11651 FRONT VIEW RIGHT SIDE VIEW (FOR 38AUD SYSTEMS) NOTES/ 1- MINIMUM CLEARANCE (LOCAL CODES OR JURISDICTION MAY PREVAIL): A. BOTTOM TO COMBUSTIBLE SURFACES: 0 INCHES. 8- OUTDOOR COIL, FOR PROPER AIR FLOW- 36 INCHES ONE SIDE, 12 INCHES THE OTHER. THE SIDE GETTING THE GREATER CLEARANCE IS OPTIONAL. C. OVERHEAD: 60 INCHES, TO ASSURE PROPER OUTDOOR FAN OPERATION. D. BETWEEN UNITS : CONTROL BOX SIDE- 42 INCHES PER NEC. E- BETWEEN UNIT AND UNGROUNDED SURFACES: CONTROL 80X SIDE, 36 INCHES PER NEC. F. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES: CONTROL BOX SIDE. 42 INCHES PER NEC. 2. WITH EXCEPTION OF THE CLEARANCE FOR THE OUTDOOR COIL AS STATED IN NOTE 18, A REMOVABLE FENCE OR BARRICADE REQUIRES NO CLEARANCE. 3. UNITS MAY BE INSTALLED ON 009305IIBLE FLOORS MADE FROM WOOD OR CLASS A. 8 OR C ROOF COVERING MATERIAL. SERVICE VALVE CONNECTIONS UNI( SUCTION L000ID 386520/ 1 -1/8 (28.61 3/8 19.51 3860008 -I/O 1 [28.61 1/2 (12.11 3865212 1-3 /8 [34.91 112 (12.11 3860214 1.3/8 [34.91 5/8 (15.91 3846012 1 -1/8 128.61 3/8 19.51 3640014 1 -3/8 (34.91 1/2 (12.11 38611007 1 -1 /8 [28.61 3/8 18.51 3860008 1-1/8 (28.61 1/2 (12.71 3860012 1.3 /8 134.91 I/O (12.11 5 -3/8 CG T CENTER OF GRAVITY (1351 DIRECTION OF AIR FLOW DIMENSIONS IN I 1 ARE IN MN LIOOID CONNEC0(0 (SEE CHART FOR 5I1E1 1nrE 02/17/09 12/30/08 5.7/8 (1491 11 -1 /4 (2651 /20558 RIGHT(1DE VIEW 38AUZ6*)T1) 38AU0 SYSTEMS) CONDENSING UNIT l 3 38A01 / 38AU0 / 38AU0 - 07/08/12/14 S�846500349 , (FOR REW 3.0 Commercial Split Systems Builder 1.13 Page 9 of 18 Project: - Untitled3 Prepared By: UNIT UNIT WEIGHT /8/11V1 40RUA -14 695 Hit 1315 kg] 40004 -16 713 Ibs (323 kg] 40006-25 730 Ibs 1331 kg] 40605.14 661 Ibs 1300 kg] 40605 -16 671 Ibs (307 kg] 40631.25 683 Ibs (310 kgl 1' -4 1 /16' (401.3] 1 5/8' (41.31 ALTERNATE ENTRANCE FOR POWER WIRING ALTERNATE ENTRANCE FOR COIL 1086(6TIO DUCT FLANGE (SEE NOTE 151 Certified Drawing for SS -1 09/24/2009 02:07PM Top 0 UNITED P.O. CCN 4808 IRIS DOCUMENT IS TN[ PROPCRTI OF CARRIER CORIOIIAiION TECHNOLOGIES SIRCIISI. NI NO IS OELIXERED UPON THE [PRP/ CONDITION INA1 INI CARRIER 13101 LORELEI] WILE :OT RE DRCLOS)D ON RIP RITXOUI CARIIP ICONroRATION'S WILE T[N CONSENT. 00X1]1101 01 T0000 0NARIN01 01 DOCMONIS 0031 X01 (013)1 11 PR1 P(RF/9RNC1 ON ACC0PTRCE OF 0/91:001. ALTERNATE RETURN AIR INTAKE 1' -5 1 /4' 3 11/16' 193.71 ONDEN5ATE DRAIN 1 5/8' 0.0 (41.31 2' 4 3/16' (116.31 LEFT SIDE 1438.21 3 I/O' (79.4] 1/2' TIP LTERNAIE DRAIN LOCATION RETURN AIR INTAKE - 1'-4 1/2' -- (419.11 6' 11.1/4 1 A0.. 1 ' -6 3/8' rJ�. -�1 3/6' -� (461.11 161.1) f 1(33 .58' -- 1390.51 ACCESS FOR CONTROLS MOTOR AND 6EL1 ACCESS FOR CONTROLS, MOTOR AND BELT UCT FLANGE ISFF NOTE 451 TYP 2 PLACES 1' -6 1/2' (469.91 6 3/4'- (171.51 3 1 /8' 179.41 3' 6 3/4' 11085.9] T' 5' (2260.61 FRONT 801. 004(65(040 IN I 1 ARE IN MILLIMETERS. DIREC1ION5 OF AIRFLOW. 3. RECOMMENDED CLEARANCE: REAR: 3 14. 076 owl FRONT: 2 If 6 in. 1762 mo] RIGHT SIDE: 2 11 6 in. 1762 881 LEFT SIDE: 2 ft 6 in. 1762 80) LOCAL CODES OR JURISDICTION MAY PREVAIL. 4. LIQUID PIPING NOT SUPPLIED BY CARRIER. 5. DUCT FLANGE IS FACTORY SUPPLIED AND FIELD INSTALLED. ACCESSORY SEE DRAWING DISCHARGE PLENUM 4064500997 ECONOMIZER 4064501000 STEAM COIL 4064501000 /00 WATER COIL 40114501000 RETUNR AIR GRILLE 40144500997 OVERHEAD SUSPENSION 4094500997 SUBBASE 4066500997 ELECTRIC /EAT O 4068501002 0 UNRELEASED DA1A 1.0' TYP 125.41 - 54::8' e3. 6 RETURN A'CA 7/8' DIA (POWER (CRT) 122.21 1 1/2' 138.11 1 1 /8' DIA FOR 100UID CONNECTION 128.61 1 3/4' DIA FOR SUCTION CONNECTION 4' -8 1/16' 144.51 (1423.91 3'-6 5/16' 7/0' DIA FOR ITV BULB CONNECTION (938.21 122.2] 1'-9 3/16' (53 .71 1' -7 1/16' 7' -2 1/16' 1484.17 1357.11 11 1/16' 1 1' -4 1/16' 1280.91 1/01.91 t1 I/O ' RETURN 128.6] AA CTURX AR 1,./1� 1 3/4' DIA. FOR SUCTION CONNECTION t' 9144.51 J1- 1(I48' DIA. FOR LI0UID CO44E11(06 RIGHLSIDE �I1 `51, DAIS 04/15/09 SUPUCLD(1 01/26/09 FAN COIL UNITS 40RU A / S - 14 / 16 / 25'._.1 \GI L) 40RU500028 8(Y 4.0 Commercial Split Systems Builder 1.13 Page 10 of 18 Project: -Untitled3 Prepared By: Guide Specification for SS -1 09/24/2009 02:07PM HVAC Guide Specifications Comercial Air - Cooled Condensing Units Size ~9 th Tons, Nominal Carrier Model 38AUZ; Sizes 007 -014 Part 1 — General, 1.01 SYSTEM DESCRIP1 ON Outdoor - mounted, air- coel) eu condensing unit suitable for on- the - ground or rooftop installation. Unit shall consist of a reciprocating or scroll air- cc?Idi:ioning compressor assembly, an air - cooled coil, propeller -type condenser fans, and a control box. Unit shall dischargtjpply air upward as shown on contract drawings. Unit shall be used in a refrigeration circuit matched with a packages e;andling unit. 1.02 QUALITY ASSURANCE A. Unit shall be rated in accordance wfith,ARI Standard 360 -2000. B. Unit construction shall comply with AN I /ASHRAE 15 safety code latest revision and comply with NEC. C. Unit shall be constructed in accordance - vi +h UL 1995 standard and shall carry the UL and UL, Canada label. D. Unit cabinet shall be capable of withstanui, g` 500 -hour salt spray exposure per ASTM B117 (scribed specimen). E. Air - cooled condenser coils for hermetic corrar:;ssor units (38AUZ) shall be leak tested at 200 psig, and pressure tested at 428 psig. t� F. Unit shall be manufactured in a facility registered-4 O 9001:2000 manufacturing quality standard. 1.03 DELIVERY, STORAGE, AND HANDLING Unit shall be shipped as single package only, and shall t Bored and handled according to unit manufacturer's recommendations. 1.04 WARRANTY (FOR INCLUSION BY SPECIFYING ENGINEEI t� Part 2 — Products 2.01 EQUIPMENT A. General: Factory- assembled, single piece, air - cooled condensing unit. ContainedQ.cithin the unit enclosure shall be all factory wiring, piping, controls, compressor, holding charge (Puron), and social features required prior to field start -up. B. Unit Cabinet: - f 1. Unit cabinet shall be constructed of galvanized steel, bonderized and coated Azt..9 a prepainted baked enamel finish. 2. A heavy -gage roll- formed perimeter base rail with forklift slots and lifting holes shallve.provided to facilitate rigging. C. Fans: 1. Condenser fans shall be direct driven, propeller -type, discharging air vertically upward. ' 7 2. Fan blades shall be balanced. 3. Condenser fan discharge openings shall be equipped with PVC - coated steel wire safety guardss...g 4. Condenser fan and motor shaft shall be corrosion resistant. D. Compressor: 1. Compressor shall be of the hermetic scroll type (AUZ). -� 2. Compressor shall be mounted on rubber grommets. v�Fi 3. Compressors shall include overload protection. 4. Compressors shall be equipped with a crankcase heater. 5. Compressor shall be equipped with internal high discharge temperature protection (38AUZ007 and 012 only). E. Condenser Coil: 1. Condenser coil shall be air - cooled and circuited for integral subcooler. 2. Coil shall be constructed of aluminum fins mechanically bonded to internally grooved seamless copper tubes which are then cleaned, dehydrated, and sealed. Commercial Split Systems Builder 1.13 Page 11 of 18 Project: - Untitled3 Prepared By: Guide Specification for SS -1 09/24/2009 02:07PM F. Refrigeration Components: Refrigeration circuit components shall include liquid line service valve, suction line service valve, a full charge of compressor oil, and a holding charge of refrigerant. G. Controls and Safeties: , 1. Minimum control functions shall include: Q a. Control wire terminal blocks. -"fif b. Compressor lockout on auto -reset safety until reset from thermostat. 2 /Minimum safety devices which are equipped with automatic reset (after resetting first at thermostat), shall €clude: a. f1gh discharge pressure cutout. b. Lo?w pressure cutout. c. Hig! (ischarge temperature cutout (38AUZ008 and 012 only). H. Operating Ch815-:cteristics: 1. The capacity the condensing unit shall meet or exceed Btuh at a suction temperature of F. The power corsum:?ption at full Toad shall not exceed kW. 2. The combination- cl'ilhe condensing unit and the evaporator or fan coil unit shall have a total net cooling capacity of B uJ ..or greater at conditions of cfm entering -air temperature at the evaporator at F wet bulb and r(.6 F dry bulb, and air entering the condensing unit at F. 3. The system shall have an `1ER of Btuh/Watt or greater at standard ARI conditions. I. Electrical Requirements: 1. Nominal unit electrical chara tc zsitics shall be v, 3 -ph, 60 Hz. The unit shall be capable of satisfactory operation within voltage limits o1-?<\ v to v. 2. Unit electrical power shall be single - -int connection. 3. Unit control circuit shall contain a 24tvlonsformer for unit control. J. Special Features: 1. Low- Ambient Temperature Control: A low- ambient temperature control shall be a ble as a factory- installed option or as a field- installed accessory. This low- ambient control shall regullte speed of the condenser -fan motors in response to the saturated condensing temperature of the unit. Th6G ntrol shall maintain correct condensing pressure at outdoor temperatures down to —20 F. 3. Optional Condenser Coil Materials: c. E- Coated Aluminum -Fin Coils: Coils shall have a flexible epoxy polymer coating uniformly applied to all coil surface ai-Fa;,without material bridging between fins. Coating process shall ensure complete coil encapsulation ,! Color shall be high gloss black with gloss requirements of 60° of 65 to 90% per ASTM D523 -89. Uniform dGfilm thickness from 0.8 to 1.2 mil on all surface areas including fin edges. Superior hardness chara.9cristics of 2H per ASTM D3363 -92A and cross hatch adhesion of 4B -5B per ASTM D3359 -93. Impact rest hce shall be up to 160 in./lb (ASTM D2794 -93). Humidity and water immersion resistance shall be up to -tc, minimum of 1000 and 250 hours respectively (ASTM D2247 -92 and ASTM D870 -92). Corrosion duraoilli:y shall be confirmed through testing to no less than 1000 hours salt spray per ASTM B117 -90. Coil construction shall be aluminum fins mechanically bonded to copper tubes. Commercial Split Systems Builder 1.13 Page 12 of 18 Project: - Untitled3 Prepared By: Guide Specification for SS -1 09/24/2009 02:07 P M 421 Unit- Mounted, Non -Fused Disconnect Switch: 'witch shall be factory- installed and internally mounted. NEC and UL- approved non -fused switch shall provide unifl ower shutoff. Switch shall be accessible from outside the unit and shall provide power off lockout caoaT lity. u• fnn 66, To Commercial Split Systems Builder 1.13 Page 13 of 18 Project: - Untitled3 Prepared By: Guide Specification for SS -1 09/24/2009 02:07PM HVAC Guide Specifications Commercial Packaged Air - Handling Unit Size R Ae: 2'490 to 7,000 Cfm, Nominal Airflow, 6 to 15 Tons, Nominal Cooling G. Carrier Model Nmber: 40RUA ('Bract- Expansion Coil) iA Part 1 — General 1.01 SYSTEM DESCRIR "! N A. Indoor, packaged ir•■ ;andling unit for use in commercial split systems. Unit shall have a multipoise design and shall be capable of hoiR:Intal or vertical installation on a floor or in a ceiling, with or without ductwork. (Only vertical units are to be app d without ductwork.) B. Unit shall have a direct- experision coil and shall be used in a refrigerant circuit with a matching air - cooled condensing unit. r,(}/ 1.02 QUALITY ASSURANCE `. A. Coils shall be designed and tested ? c ordance with ASHRAE 15 Safety Code for Mechanical Refrigeration, latest edition. B. Unit shall be constructed in accordance n i`h ETL and ETL, Canada standards and shall carry the ETL and ETL, Canada labels. C. Unit insulation and adhesive shall comply withif FPA -90A requirements for flame spread and smoke generation. Insulation shall contain an EPA - registered imrrit,oilized antimicrobial agent to effectively resist the growth of bacteria and fungi as proven by tests in accordar with ASTM standards G21 and 22. D. Unit shall be manufactured in a facility registered tocthe,.SO 9001:2000 manufacturing quality standard. E. Direct - expansion coils shall be burst tested at 435 psira_nd leak tested at 150 psi. 1.03 DELIVERY AND STORAGE t Units shall be stored and handled per manufacturer's recommendations. 1.04 WARRANTY (FOR INCLUSION BY SPECIFYING ENGINEER) "!j, Part 2 — Products 2.01 EQUIPMENT Indoor mounted, draw -thru, packaged air - handling unit that can be used wit t'j rwithout ductwork in a suspended horizontal configuration or free - standing vertical configuration. Unit shall consis•;� forward -curved belt- driven centrifugal fan(s), motor and drive assembly, prewired fan motor contactor, facto rstalled refrigerant metering devices, cooling coil, 2 -in. disposable air filters, and condensate drain pans for vertic,or horizontal configurations. A. Base Unit: 0 1. Cabinet shall be constructed of mill - galvanized steel. NJ- 2. Cabinet panels shall be fully insulated with 1 /2 -in. fire- retardant material. Insulation s;Iba!! contain an EPA - registered immobilized antimicrobial agent to effectively resist the growth of bacteria re) fungi as proven by tests in accordance with ASTM standards G21 and 22. ti" 3. Unit shall contain non - corroding condensate drain pans for both vertical and horizontal appl!c4ions. Drain pans shall have connections on right and left sides of unit to facilitate field connection. Drain`Nars shall have the ability to be sloped toward the right or left side of the unit to prevent standing water from acceuilating in pans. ,, 4. Unit shall have factory- supplied 2 -in. throwaway -type filters installed upstream from the cooling coil biter access shall be from either the right or left side of the unit. B. Coils: 0 Coils shall consist of 3 rows (standard) or 4 rows (high capacity) of 3 /8-in. copper tubes with sine -wave aluminum fins bonded to the tubes by mechanical expansion. Coil tubing shall be internally rifled to maximize heat transfer. Suction and liquid line connections shall be made on the same side of the coil. Direct - expansion coils shall feature factory- installed thermostatic expansion valves (TXVs) for refrigerant control. The TXVs shall be capable of external adjustment. C. Operating Characteristics: Unit shall be capable of providing cfm airflow at an external static pressure of in. wg. D. Motor: Commercial Split Systems Builder 1.13 Page 14 of 18 Project: - Untitled3 Prepared By: Guide Specification for SS -1 09/24/2009 02:07PM 1. Fan motor of the size and electrical characteristics specified on the equipment schedule shall be factory supplied and installed. 2. Evaporator -fan motor shall have permanently lubricated, sealed bearings and inherent automatic -reset thermal overload protection (motors smaller than 5 hp) or manual reset calibrated circuit breakers (motors equal or larger than 5 hp). Evaporator motors are designed specifically for Carrier and do not have conventional horsepower (hp) ratings listed on the motor nameplate. Motors are designed and qualified in `` the "air- over" location downstream of the cooling coil and carry a maximum continuous bhp rating that is the maximum application bhp rating for the motors; no "safety factors" above that rating may be applied. aQ\ll evaporator -fan motors 5 hp and larger shall meet the minimum efficiency requirements as established by Op Energy Policy Act of 1992 (EPACT), effective October 24, 1997. E. Special Fgatures: 1. Alterr;te Motor and Drive: An alterr�''te motor and medium or high- static drive shall be available to meet the airflow and external static pressure rQj Jirements specified on the equipment schedule. 10. Economizer: 7 Economizer for ventilation or "free" cooling shall be factory provided for field installation. Fc(free cooling applications, economizer shall be compatible with factory- supplied thermostat; economizer dar3)ers shall open when outdoor air enthalpy is suitable for free cooling. Economizer shall be compatible with: �i tory- supplied CO2 sensor; economizer dampers shall open when indoor CO2 level rises above predeterraned set point. Q[� 12. Overhead Suspension Package: Package shall include necessary brackets to support units in a horizontal ceiling installation. Commercial Split Systems Builder 1.13 Page 15 of 18 Project: -Untitled3 Prepared By: Guide Specification for SS -1 09/24/2009 02:07PM Commercial Split Systems Builder 1.13 Page 16 of 18 r ;..,;;.71 COMMERCIAL SPLIT SYSTEMS 38AUZ 6 TO 12.5 TON AIR -COC,T ED CONDENSING UNITS with PURON® REFRIGERANT These commercial quality ai4 r- 'cogled condensing units are easily connected by refrigerant lines and low voltage control wiring to matching Carrier packaged air - arcing units or other suitable evaporator units. They are ideal for new construction or renovation applications where quality and peti lance are required. ARI Standard 340/360 US Certified to ISO 9001:2000 �ASNRiA� COMPLIANT ENERGY STAR BASE UNIT STANDARD FEATURES: • Puron® (R -410A) HFC refrigerant partial charge • Single -stage cooling capacity control on all models with Novation TM Heat Exchanger Technology Condenser Coils • Standard one -year unit warranty, 5 -year compressor plan and 3 -year parts plan on Novation coil • Cooling operating range up to 125 F (52 C) and down to 35 F (2 C) • Brass suction and liquid line service valves :Fully Hermetic Scroll compressor with crankcase heater • 'w terminal board facilitating simple safety circuit tr • 1 ?reshooting and simplified control box arrangement. 24 -of., 5va control system • High anYr., pressure switches. • Comfort )\tertTM Diagnostic Board: • LED 4.56-Go and fault code • Built in tiro P. card anti -short cycle • Phase protec it \ • Fault code retch ) logic • Low voltage comprcyor contactor protector • UL and UL, Canada apply tt,.`q dard units; 575 -volt units UL, Canada only. a • Full perimeter base rails with built i rigging adapters and fork truck slots • Pre - painted exterior panels and primer!S:oafed interior panels tested to 500 hours salt spray prote�''c 1 • Direct drive permanently lubricated condenser'tan motors • All units factory run tested • Compressors mounted on independent vibration isc111�rs U' Commercial Split Systems Builder 1.13 Page 17 of 18 COMMERCIAL SPLIT SYSTEMS 40RUA DIRECT EXPANSION PACKAGED AIR - HANDLING UNITS with PURON® REFRIGERANT • 40RUA DIRECT EXPANSION PACKAGED AIR - HANDLING UNITS The 40RUA units are completely packaged direct expansion air - handling units offering the ultimate in installation ease and flexibility. Combined with Carrier 38AU Series condensing units these packaged air handling units offer system capacities from 6 up to 15 tons. These units may be installed in either the vertical or horizontal configuration with no modifications. Powerful fan systems allow easy adaptation to existing ductwork. Heating capability is provided by electric heaters, hot water coils or steam coils. 40RUA 6 TO 10 TON CHASSIS SHOWN 40RUA DIRECT EXPANSION PACKAGED AIR - HANDLING UNITS STANDARD FEATURES 1. PURON (R -410A) HFC Refrigerant 2. Cleanable insulation treated with an anti- microbial agent. 3. Two sloped condensate pans on each unit for horizontal or vertical applications. 4. 2 inch filters. 5. Powerful belt -driven forward curved fans. 6. Factory- installed fan motor and contactor. 7. Refrigerant metering devices (TXV's) -- factory installed. 8. Easy maintenance -- removal of a single panel allows access to virtually all components. 9. Single blower on 07 to 12 sizes; dual blower on 14 to 16 sizes. 10. 24 -volt terminal block for control wiring connection. 11. Standard one year warranty. € tified to ISO 9001:2000 ?(� n.. the environmentally sOLlrafrigerant Commercial Split Systems Builder 1.13 Page 18 of 18 Boeing Purchase Request For Reference Only. Not an authorization to commence work. Boeing Control # 4948,2 User ID: Report: ENT1059 j� Database: * *PLEASE FAX ,P,ftOVISIONER ( Kirkpatrick, Stephanie C ) WITH PRICING & ESTIMATED DELIVERY DATE(S) ** CJ m108000 MXESPRD1 Vendor: U Washington Air Reps (valid) �� 3290 146th PI SE Ste A Bellevue WA '8907 Tel: (425) 562 -1150 `', Fax: (425) 562 -5123 CPA #: c� t ,_, Ship to: Seattle 2 -31 Stores WA 2 -31.1 MX 7644 E MARGINAL WAY SO DOOR N11 SEATTLE WA 98108 Atten: Thomas, Lee M Prov: Kirkpatrick, Stephanie Tel: 206 - 662 -4039 Fax: 425 - 294 -9030 Status: WINFO Date of Issue: 09/29/2CPJ Date Required: 10/30/20091/, Requested By: Thomas, Lee kit Phone: 206 - 655 -8243 T< Payment Terms: Ship Via: Feight Terms: F.O.B.: Co Delivery Point: Attention Mike Vance, 206 - 544 -8479 Comments: Air Conditioner WASH AIR REPS 10/5 c/ See long description field in item detail for unit specification : \'► Line rt� , UOM Item Qty UOM Item # Manufacturer Catalog Number Ivlpapl Number Price Est On Dock 1 1 EA CARRIER 38AUZ OUTDR CARRIER 4OR UA INDR Description: Air Conditoner, Split System, Air Cooled, 12.5 Ton Nom capacity - Job 5285 -10 Erick 9ering Work Order 9266456 �� �� Specification 11 -140 UPS Room Air Conditioner, Split Type System Using R410 Refrigerant Ton Nominal Capacity With 5 KW Electric Heat - By Lee M Thomas, Boeing Plant 2 Plant Engineering, 206 - 655 -8243 \ f :5.;., . lJ0� Run Date: 10/13/2009 12:00 AM Page 1 of 3 ?( B Boeing Purchase Request ;�E/n 5 For Reference Only. Not an authorization to commence work. Boeing Control # 4948tg User ID: Report: ENT1059 7/ Database: * *PLEASE FAX'PROVISIONER ( Kirkpatrick, Stephanie C ) WITH PRICING & ESTIMATED DELIVERY DATE(S) ** v_ m108000 MXESPRDI Line Item Qty UOM Ci UOM Item # Man�acturer Catalog Number Model Number Price Est On Dock System to be installe &)iXh minimal modification to existing ductwork for existing air conditioner AHU -1A and Condenser COND -1A foc. ^atod in garage level of Boeing 11 -14 building in Tukwila Washington. Existing system consists of a Carrier Moder<roaR016 AHU suspended from 1st floor slab of building and a Carrier Model 38AED16 condenser mounte &fin an housekeeping pad adjacent to the exterior of the building as shown in attached drawing 11- 014- M528R1 Replacement units shall be interconnecte�d.with customer provided copper type ACR tubing system. Customer shall provide all installation labor. Vendor il;il be provide initial start up service after system has been installed and power applied. 1% The new fan coil will be configured to supply cooling v4tri an ETL listed electric heat stage of a nominal 5kw at 460 VAC 3 phase. The nominal capacity shall be 6,000 ;fray at 0.6 inch wc. The total nominal cooling capacity of the fan coil shall be a minimum 150,000 btuh at 80F Td 467F Twb. A factory installed thermostatic expansion valve rated for R410 service shall be installed. �/� VQ�(‘ The fan coil controls shall provide with an analog type point of conn*n ( 0 to 10 volts DC) to operate an external economizer damper. The unit shall also be equipped with seism restraint provisions and be equipped to be supported from overhead. The fan coil shall be equipped v✓ ti" a integral condensate drain pan and gravity condensate drain point of connection. The new outdoor condenser unit will be configured to rest on an concrete housekeep hg pad with seismic restraints. The condenser unit shall be equipped for low ambient operation down to a ri,iirj^ium OSA of OF. The condenser shall be sized to reject the rated load of the fan coil unit at an OSA temp of 9e unit shall be equipped with refrigerant high discharge pressure cutout, refrigerant low pressure cutout. Sb tign and liquid line service valves, crankcase heaters, sight glasses, and filter drier shall be provided. 0 f� Power for the outdoor condenser unit and the indoor fan coil shall be supplied to a single point at each J,at 460 VAC 3 phase 60 hz.. Each unit shall be equipped with a unit mounted non -fused disconnect switch. it , design and installation of the power feeds shall be by the customer. uo. Run Date: 10/13/2009 12:00 AM Page 2 of 3 ,r. Boeing Purchase Request BLiFb.v' For Reference Only. Not an authorization to commence work. s'\ ' / Boeing Control # 4948k User ID: Report: ENT1059 .7, Database: **PLEASE FAX - PROVISIONER ( Kirkpatrick, Stephanie C ) WITH PRICING & ESTIMATED DELIVERY DATE(S) ** �v_ m108000 MXESPRDI Line t�X\ UOM Item Qty UOM Item # Manufacturer Catalog Number Model Number Price Est On Dock The overall unit shall�ce`�;JL listed with permanent approval stickers applied to each unit. The air handler construction shall compiy;njth NFPA -90A for flame spread and smoke generation. The new system shall utilize type 410 or non -ozone imku;iing equivalent refrigerant and delivered with a holding charge in both the condenser and fan coil to maint in system cleanliness. The new system shall have an minimum efficiency EER ) of 11.0 based on ARI 340/ (30. in The unit shall be controlled by programrnar!.e multi -stage thermostat with 7 day clock and holiday scheduling to be included with the hardware. The con :, r provided shall also be capable of providing an externally monitored summary trouble alarm. /fir, The supplier shall provide a copy of all wiring schematics in PDF electronic format for the new units within 14 calendar days of order confirmation. The schematics sh..11 he forwarded the installation project engineer, Lee Thomas, Boeing Plant 2 Plant Engineering, email lee.m.t-hSr.?las@boeing.com Charge Line: 08 -G -G- 0282 - 6464- OGPUCP -926- Work Order #:/49266464 Req #: 680599 G PCW C -00000 n Sub Total: C. Tax: Total: -/ Provisioner: Date:Lo0 Approved By: Date: j -, ta. /(7 . `0- t.1 Run Date: 10/13/2009 12:00 AM Page 3 of 3 eitmEZAW Boeing Control # 5308904 Report: ENT1080 **PLEASE FAX PROVISIONER For I Reference ( Kirkpatrick, Boeing Only. Not Stephanie Purchase an authorization Order to commence work. CC?' ��� User ID: m108000 N. Database: MXESPRD I C ) WITH PRICING & ESTIMATED t;AEIVERY DATE(S)** Vendor: Ship to: (0` WASHINGTON AIR REPS INC Seattle 2 -31 Stores OV 3290 146TH PL SE STE A WA 2 -31.1 MX BELLEVUE WA 98007 -6467 7644 E MARGINAle,). Y SO DOOR N11 Tel: SEATTLE '� 98108 WA Fax: CPA #: Atten: T^. :A s, Lee M r Prov: Kirkpatrick, Stephanie Date of Issue: 11/17/2009 �� Payment Terms: NET 30 C Tel: 206 - 662 -4039 Date 10/30/2009 Q� Ship Via: ROAD Fax: 425 - 294 -9030 Requested Thomas, Lee M Ca Freight Terms: Supplier Pays Status: APPR Phone: 206- 662 -2841 S" ‘s../ F.O.B.: Destination Delivery Point: Attention Mike Vance, 206 - 544 -8479 ,c)) Comments: Air Conditioner WASH AIR REPS 10/5 - Se4 I no g description field in item detail for unit specification Line •`('' Item Qty UOM Item # Manufacturer ON' Catalog Number Model Number Unit Cost Line Cost 1 1 EA <&' CARRIER 38AUZ OUTDR $14,150.00 $14,150.00 Description: ASSIGNEr^ ?BUYER CONTACT STEPHANIE KIRKPATRICK FOR FAXED QUOTE / Air Conditoner, Split Syst6.mi`+ir Cooled, 12.5 Ton Nom capacity - Job 5285 -10 Engineering Work Order 9266456 Specification 11 -140 UPS Room Air Conditioner, Split Type System Using R410 Refrigerant, 12.5 Ton Nominal N' Capacity With 5 KW Electric Heat C) l,\ By Lee M Thomas, Boeing Plant 2 Plant Engineering, 206 - 655 -8243 Run Date: 12/15/2009 12:00 AM Page 1 of 3 .gElElAf Boeing Control # 5308904 Report: ENT1080 I `*PLEASE FAX PROVISIONER( For Reference Kirkpatrick, Boeing Only. Not Stephanie Purchase an authorization Order to commence work. �<0 �� User ID: m108000 ��\ Database: MXESPRD1 C ) WITH PRICING & ESTIMATED D, DATE(S)** Line Item SO1" Qty UOM Item # Manufacturer Catalog Number A' yiel Number Unit Cost Line Cost System to be installed with minimal modification to existing ductwork r existing air conditioner AHU -1A and Condenser COND -1A located in garage level of Boeing 11 -14 bi:;!Jing in Tukwila Washington. Existing system consists of a Carrier Model 40RR016 AHU suspended from 0oor slab of building and a Carrier Model 38AED16 condenser mounted on an housekeeping pad adi"jent to the exterior of the building as shown in attached drawing 11- 014- M528R. �A,� �V Replacement units shall be interconnected with s t'omer provided copper type ACR tubing system. Customer shall provide all installation labor. Vendor shavc'provide initial start up service after system has been installed and power applied. Q G The new fan coil will be configurecttos pply cooling with an ETL listed electric heat stage of a nominal 5kw at 460 VAC 3 phase. The nominal, racity shall be 6,000 cfm at 0.6 inch wc. The total nominal cooling capacity of the fan coil shall be a minim 150,000 btuh at 80F Tdb / 67F Twb. A factory installed thermostatic expansion valve rated for ReTservice shall be installed. G2 The fan coil controls small provide with an analog type point of connection (0 to 10 volts DC) to operate an external econorr.j Vdamper. The unit shall also be equipped with seismic restraint provisions and be equipped to rnipported from overhead. The fan coil shall be equipped with a integral condensate drain pan and gravity, -fndensate drain point of connection. Q Ths r, w outdoor condenser unit will be configured to rest on an concrete housekeeping pad with seismic syraints. The condenser unit shall be equipped for low ambient operation down to a minimum OSA of OF. The r\condenser shall be sized to reject the rated load of the fan coil unit at an OSA temp of 95F. The unit shall be ►\' equipped with refrigerant high discharge pressure cutout, refrigerant low pressure cutout. Suction and liquid C-9 N line service valves, crankcase heaters, sight glasses, and filter drier shall be provided. C3(./ Power for the outdoor condenser unit and the indoor fan coil shall be supplied to a single point at each unit at 460 VAC 3 phase 60 hz.. Each unit shall be equipped with a unit mounted non -fused disconnect switch. The design and installation of the power feeds shall be by the customer. Run Date: 12/15/2009 12 :00 AM Page 2 of 3 &APTIFIAfff Boeing Control # 5308904 Report: ENT1080 I **PLEASE FAX PROVISIONER For Reference ( Kirkpatrick, Boeing Only. Not Stephanie Purchase an authorization Order to commence work. 0 ccr \�� User ID: m108000 1\. Database: MXESPRD1 C ) WITH PRICING & ESTIMATED^ SLIVERY DATE(S)** Line Item CO// Qty UOM Item # Manufacturer Catalog Number lade! Number Unit Cost Line Cost The overall unit shall be UL listed with permanent approval stickers a plied to each unit. The air handler construction shall comply with NFPA -90A for flame spread ands `eke generation. The new system shall utilize type 410 or non -ozone impacting equivalent refrigerant and c_'-ecvzred with a holding charge in both the condenser and fan coil to maintain system cleanliness. ThGrew system shall have an minimum efficiency ( EER ) of 11.0 based on ARI 340/360. �^�'-1. V The unit shall be controlled by programmable m0ittage thermostat with 7 day clock and holiday scheduling to be included with the hardware. The control! N'rovided shall also be capable of providing an externally monitored summary trouble alarm. O t) The supplier shall provide a copy awl wiring schematics in PDF electronic format for the new units within 14 calendar days of order confirma`ii he schematics shall be forwarded the installation project engineer, Lee Thomas, Boeing Plant 2 Plartp gineering, email Iee.m.thomas @boeing.com Charge Line: 08 -G -G- 0282 - 6464- 0GPU01926- Work Order #: 9266464 Req #: 680599 GPCWC -00000 h Sub Total: $14,150.00 '�� Tax: $0.00 � Total: $14,150.00 iA Provisioner: ' Date: Approved By: ._ O� Date: , ;fir toP Run Date: 12/15/2009 12:OOAM Page 3 of 3 02 -01 -2011 City of f ?'ukwala Jim Haggerton, Mayor Department of Community Development Jack Pace, Director MARK CLEMENT PO BOX 3707 MC 1W-10 SEATTLE WA 98124 RE: Permit No. M10 -112 2925 S 112 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/27/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/27/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, .-vi,lud ,i__ Bill Rambo Permit Technician File: Permit File No. M10 -112 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • _ • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -112 PROJECT NAME: BOEING #11 -14 SITE ADDRESS: 2925 S 112 ST X Original Plan Submittal - Response to Correction Letter # _ DATE: 08 -09 -10 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: v Building ivision Public Works 4w\ 4w■ Fire Prevention Structural 3-(0 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08-10-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route ® Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-07-10 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BOEING COMPANY, THE 3125442535 100 N Riverside M/C 5003 -4027 Chicago IL 606061596 Out Of State Corporation UBI No. 178005030 Status Active License No. BOEINC`294ML License Type Construction Contractor Effective Date 7/13/1971 Expiration Date 1/14/2011 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date SHRONTZ, F A Cancel Date 01/01/1980 Amount CONDIT, P M 22 01/01/1980 HDOG24934780 GIVAN, B E 10/01/2010 01/01/1980 WOODARD, R B 09/22/2009 01/01/1980 ACE AMERICAN INS CO CRUZE, D D 01/01/1980 KING, C G $5,000,000.00 01/01/1980 20 BEIGHLE, D P HDOG21734378 01/01/1980 10/01/2007 COLLINS, T J 01/01/1980 09/25/2006 BUDINICH, T M ACE AMERICAN INS CO 01/01/1980 10/01/2005 READ, PAUL Secretary 01/01/2001 $5,000,000.00 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FEDERAL INS CO 81312466 01/01/2002 Until Cancelled $12,000.00 01/14/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 22 ACE AMERICAN INS CO HDOG24934780 10/01 /2009 10/01/2010 $10,000,000.00 09/22/2009 21 ACE AMERICAN INS CO HDOG2373284110/01/2007 A 10/01/2009 $5,000,000.00 09/26/2008 20 ACE AMERICAN INS CO HDOG21734378 10/01/2006 10/01/2007 $5,000,000.00 09/25/2006 19 ACE AMERICAN INS CO HDOG21731869 10/01/2005 10/01/2006 $5,000,000.00 09/26/2005 18 ACE AMERICAN INS CO HDOG21731869 10/01/2003 10/01/2005 $25,000,000.00 11/10/2004 17 ACE AMERICAN INS CO HDOG21731869 10/01/2003 10/01/2004 $5,000,000.00 10/24/2003 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/01/2010 D D • • PROJECT SITE OIN: . 0 Q�O 5 ' , AUBURN TO TA S MA AUBURN I REPLACE CRITICAL COOLING SYSTEM © 11—/ }UM Tal-1 Ps 11-I4OBUILDING REPLACE CRITICAL COOLING SYSTEM JOB # 5285-109266456 C T" VAP PROJECT AREA GARAGE LEVEL / CAFETERIA SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical EirEtectrical ffrPlumbing C as Piping My of Tukwila ii tP..r iTSG DIVISION No changes shall REVISIONS No to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal n 1 may include additional plan review fees. CODE S V VAHV BUILDING CODE: SEISMIC DESIGN: OCCUPANCY GROUP: CONSTRUCTION TYPE: TYPE 1 TOTAL BUILDING AREA: CONSTRUCTION AREA: BUILDING HEIGHT: 103 FT STORIES: 5 IBC INTERNATIONAL BUILDING CODE 2003, AS ADOPTED BY THE CITY OF TUKWILA GROUP = 1 CATEGORY = D LATITUDE = 47,33 LONGITUDE = —122.5 B -2 OFFICE, B -1 PARKING 189,064 SQ FT 390 SQ FT I SPECTRAL ACCELERATION: I SHORT PERIOD Ss= 1.25g 1SEC. 51= .42g MAR '27 2011 LHCAL D1-SCR PT o\ THAT PORTION OF GOVERNMENT LOT 2, SECTION 9, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTION OF THE NORTH LINE OF SAID GOVERNMENT LOT 2 AND THE WESTERLY MARGIN OF STATE ROAD NO.1; AND RUNNING THENCE ALONG SAID WESTERLY MARGIN OF STATE ROAD N0.1. S 18457'20" W. 972.08 FEET MORE OR LESS, TO THE NORTH BANK OF THE DUWAMISH RIVER; THENCE WESTERLY, NORTHWESTERLY, AND NORTHERLY ALONG SAID BANK OF THE DUWAMISH RIVERTO ITS INTERSECTION WITH THE NORTH LINE OF SAID GOVERNMENT LOT 2; THENCE N 89430'50 "E ALONG THE NORTH LINE OF SAID GOVERNMENT LOT 2, 845 FEET, MOE OR LESS, TO THE TRUE POINT OF BEGINNING. FILE C "!!l PY Permit No. M10 • 112 Plan review approval is subject to errors and omissions. top oval of construction documents does not authorize thr vso!ation of any adopted code or ordinance. Receipt Lpproved Field Copy and conditions is acknowledged: By Date: Q — 1 — I b City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 c 2010 114 City of Tukwila BUILDING DIVISION ISSUE FOR PERMIT 5285 - 1019266464 08/0512010 PHOJHCT SYVAHV DESCRIPTION OF WORK: REPLACE EXISTING R22 BASED SLPIT SYSTEM AIR CONDITIONER PROVIDING COOLING TO UPS ELECTRONICS ROOM WITH NEW R410 BASED SPLIT SYSTEM CONTRACTOR: BOEING GENERAL CONSTRUCTION UNIT ESTIMATED COST: $75,000 SITE ADDRESS: 11201 TUKWILA INTERNATIONAL BLVD. OWNER: BOEING COMMERCIAL AIRPLANE SEATTLE DISTRICT P.O. BOX 3707, M /S: 1W -10 SEATTLE, WA. 98124 -2207 OWNER CONTACT: MARK CLEMENT (206) 617 -2944 KINK COUNTY PARCEL NO. 0923049155 DRAW \G I \DHX "�"� DRAWING NO. SHEET NO. DRAWING TITLE REV DATE ARCHITECTURAL • 11- 140 —A0 AO COVER SHEET 1 )9/25/09 • • NECHA \ICAL • 11- 140 -0M17 0M17 GARAGE LEVEL HVAC PARTIAL PLAN B J9/25/09 • 11- 140 -0M267 0M267 GARAGE LEVEL PARTIAL PLAN — FIRE SPRINKLERS F )9/25/09 • 11- 140 -0E217 0E217 GARAGE LEVEL HVAC CONTROLS PARTIAL PLAN F D9/25/09 • 11- 14 —M2A M2A HVAC EQUIPMET SCHEDULES G D9/25/09 • 11- 14 —M334 M334 HVAC DETAILS UPS ELECTRONICS ROOM 0 ]9/25/09 • 11- 14 —M335 M335 HVAC DETAILS UPS ELECTRONICS ROOM 0 )9/25/09 • 11- 14 —M528R M528R UPS INSTALLATION — HVAC — REMOVAL R ]9/25/09 • 11- 14 —M528 M528 UPS INSTALLATION — HVAC B.2 )9/25/09 • 11— }4 —M568 M568 UPS INSTALLATION — HVAC SECTIONS AND DETAILS 0 )9/25/09 • 11- 14 —M569 M569 UPS INSTALLATION — HVAC SECTIONS AND DETAILS 0 )9/25/09 • 11- 14 —M570 M570 UPS INSTALLATION — HVAC SECTIONS AND DETAILS 0 J9/25/09 ELECTRICAL • 11- 14S -0E2 0E2 480/277V POWER MAIN FEEDERS AND PANELS C ]9/25/09 ¥1IO-l12 AUG 09 2010 PERMITCENTE REVISION BY APPROVED DATE LBOE /NCm c� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN LM THOMAS DATE 09.28.09 APPROVED BY DEPT. DATE CHECKED ENGINEER LM THOMAS CHECKED WDH APPROVED SUBTITLE COVER SHEET CURRENT REVISION 9266481 SYMBOL DATE 09.28.09 09.28.09 09.28.09 APPROVED TITLE REPLACE CRITICAL COOLING SYSTEM BUILDING 11 -14N ARCHITECTURAL MASTER COL. X —X /X —X DUWAMISH SHEET AO v\ V JOB NO. OMP NO 9266456 UWAMISH_COVER.DWC DWG NO. 11- 14N —A0 G.2 G.� 4 UNIT CONNECTION N SEE SHEET M561 N Di SELF - CONTAINED EMERGENCY EYE WASH ■I■, ■■ III i■I ■I 0M13 ■I■ 0M11 11 x8 8 8x8 EG O.B. DAMP :LANCING R (TYP.) EQUIPMENT ROOM REG.IWITH ODDSUP 48 "x34 "z4', 16 GA GxLV. STEEL 0 150 CFM 0M20 •■!III► �� �� 48 "x6" BATTERY ROOM 200 CFMG MISCELLANEOUS EQUIPMENT ROOM (2) 8 DAMPE' 8'x6" GRILLE 1 BACKD' DUCT FT ARK 8'z6" ,\ ' i i� 18" x 1 li 4 1 ►� PLENUM FOR CONTROL DAMPER INSTALLATION (TYP.) '-' • 1000 CFM 500 CFM �I 48 "x26" OUTSIDE AIR OPENING WITH 1/8. 500 C INSECT SCREEN WITH MANUAL QUADRANT - I'. e. x li�'' 48 "I34" FM GRI I AFF / 45 31� ,�' 1000 :l!I,I- RETU• , TURNING VANES (TYP) SOUND LINED DUCTWORK (TYP) 2) 48'x34' CONTROL DAMPER WITH 1/8' INSECT SCREEN (IN CLOSED AND LOCKED POSDON) C-10 _ 6000 C�� -_ �� - '' , '-' , 1000 1 , , , 8" x 1� 48 GRILE _ '_' 34" RELIEF — ' = ; 6' 10' jou 4 - F8. ,, �� AF II II 0. (3) B "x6" GPoLLES�I— '� i ��I�V7 _� — , 1'COND. © FLOOR PAN TOP DF CO �. `;- fit 48 x26' ioi r./ y 30 1 3/8" O.D. SUCTION, w 1/2" O.D. LIQUID 1 'CON D. REFRIGERANT PIPING 1/4" O,D, CONDENSATE BACKUP AC UNIT PIPING (SLOPE I /4 " /FT.) FOR BATTERY ROOD ■■ f =MEd ^ 1 1 I I U I II a _/ in ,'', ^ = -x -, NN % 1 _- %.� - W C 11 ( EXISTING ANCHO S FOR 11, 23 II AHU -I - 6 ES 54 55 1 / 11- 0140 -0M17 11- 14 -M527 11- 4 -M 28 9 /o i`>4i / 0 \ / / / i \,A\ \+1\ IRE DAMPER TYPICAL I- LEX CONNECTION 1 MAR 2 7 201 REFERENCE DRAWI \GS: 1 1- 0140 -1 M3 GARAGE LEVEL HVAC COMPOSITE PLAN 1) 2) GENERAL NOTES: DUCTWORK SHOWN ON THIS DRAWING WAS ORIGINALLY SHOWN ON RASTER DRAWING 1 1 -14L_M 1 1 .TIF. THAT DRAWING WAS ORGINALLY NUMBERED AS SHEET M1 OA AND REFERENCED ON LOBBY DRAWING 1 1.14L -1 M10 THE LOBBY DUCTWORK SHOWN ON THIS DRAWING WOULD NORMALLY BE SPLIT UPAND SHOWN ON PARTIAL PLANTS 0M1 2, 0M1 3, AND OM 17 IF CORRECTLY SPLIT ACROSS QUADRANTS. THE ENTIRE SYSTEM IS SHOWN ON THIS DRAWING FOR CLARITY. TYPICAL 2HR 24" DEEP OWB PLENUM. FIRE DAMPER AT ALL DUCT PENETRATIONS 4) EQUIPMENT SCHEDULE: EH 1: ELECTRIC FURNACE - SQUARE D MODEL B1 9, 30 KW, 460 VAC 3 PHASE, 2000 CFM @ 0.5 WG ESP, 3 STAGE OF CONTROL. INTERFACED TO HONEYWELL SYSTEM. WITH SMOKE DETECTION EH2: SAME AS EH -1 FLOOR GRILLE REMOVED FOR NEW CAS OCCUPANCY. AREA SERVED BY AC-1 N 6) ALSO SEE RASTER FILE 1 1 -14L_M 1 1 .TI F D>- CONSTRUCTION NOTES: REMOVE EXISTING DX TYPE SPLIT SYSTEM AIR CONDITIONER AHU -1 A THAT PROVIDES COOLING FOR THE UPS ELECTRONICS ROOM. MAINTENANCE HVAC TO REMOVE EXISTING R22 CHARGE IN REFRIGERATION TUBING. SEE SHEETS 1 1- 140 -0M267 AND M528R ri›. INSTALL NEW DX TYPE SPLIT SYSTEM AHU -18 AS REPLACEMENT FOR UNIT AHU -1A REMOVED ABOVE. MAINTENANCE TO INSTALL NEW R410 /PURON REFRIGERANT CHANGE WHEN COMPLETE. SEE SHEETS 11- 140 -0M267 AND M528 Dr> CONNECT CONTROLS FOR AHU -1B AS SHOWN ON SHEETS 11- 14 -M334 AND M335 13›- INSTALL NEW ECONOMIZER STAGE AND CONNECT TO NEW AIR CONDITIONER FOR ECOMOMIZER MODE OPERATION AND VENTILATION AIR REVIEWED FOR CODE COMPLIANCE APP AVED AUG 2 6 2010 City of Tukwila BUILDING DIVISION ISSUE FOR PERMIT 5285 - 10/9266464 08/05/2010 FLOCR PLA\ SCALE: 1- 8 " =1' -0" • (AD G. 0 i 0M13 0M12 0M11 0M10 I J0\ X: M16 OM15 0 4 K721 / 0M20 0M19 OM2� OM18 0M22 <EY -PLA\ SCALE: NONE RECEIVED AUG 09 2010 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INITIAL RELEASE LM THOMAS 01.08.08 DESIGN / INSTALL HVAC SYSTEM 567893 -00 LM THOMAS WDH 02.12.08 B REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS WDH 09.28.09 Z)1,41,17EZAW ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN LM THOMAS DATE 01.08.08 APPROVED BY DEPT. DATE CHECKED ENGINEER LM THOMAS SUBTITLE GARGE LEVEL HVAC PARTIAL PLAN CURRENT REVISION 9266456 SYMBOL B DATE 09.28.09 01.08.08 CHECKED APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEM BUILDING 11 -0140 MECHANICAL MASTER COL.G.2 -0/5.9 -12.6 DUWAMISH, WA SHEET 0M17 \\A JOB NO. DWG NO. 9266456 COMP NO, 11- 0140 -0M 17 co 0 Z 0 X O A 4 MATCHLINE SEE SHEET N 1 N M263 • • z 0 z \oo • • �Ir� N N • • 0- N N 0 m UD F- N \ • • N • N U 1(�T Sf -6 4 NSEE • -, 1J1 1561 4 BELOW CTWORK 13'-7 1/2" TCHLINE SEE SHEET 0 ° - DR P DRAIN ASSEMBLY • 1 N REVISION APPROVED SYM REVISION BY APPROVED DATE AS -BUILT BY WOOD /HARBINGER A RELOCATE SPRINKLER PIPING B REVISE PIPE SIZE 12/31/92 F REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS WDH 09.28.09 570718 RTEMKIN 570718 RTEMKIN D PROVIDE POWER SYSTEM E 570590 -001 02/11/93 Qi - BOE /NG 0 LEGS \) RISER MAIN CONTROL VALVES PIPE REDUCTION PENDANT SPRINKLER HEAD END OF DISTRIBUTION PIPE DRAIN OR FLUSH VALVE HALON SPRINKLER COMM ROOM PIPE CAP 1. HEADS TO BE UL LISTED AND FM APPROVED FOR ORDINARY HAZARD OCCUPANCY. 2. HANGERS WITH EARTHQUAKE STRAPS REQUIRED ON ARM —OVERS GREATER THAN TWO (2 FEET IN LENGTH. MAR 27 201i REVIEWED FOR CODE COMPLIANCE APPROVED AUG 26 2010 City of Tukwila BUILDING DIVISION CE\ERAL \OTES 1. CONNECT INTO EXISTING CROSSMAINS WHERE SHOWN AFTER APPROVED HYDROSTATIC TESTS (200 PSI FOR TWO HOURS) WITNESSED BY BOEING FIRE DEPARTMENT PERSONNEL. 2. ALL MATERIALS, FITTINGS AND INSTALLATIONS SHALL CONFORM TO N.F.P.A. SECTION 13 FOR ORDINARY HAZARD OCCUPANCY. 3. SPRINKLER LOCATIONS SHALL BE AS SHOWN ON PLAN. 4. SLOPE BRANCH AND CROSSMAIN PIPING TO DRAIN VALVE AS SHOWN. 5. PROVIDE HANGERS IN ACCORDANCE WITH N.F.P.A. SECTION 13. 6. NOTIFY BOEING FIRE DEPARTMENT 24 HOURS PRIOR TO SHUTDOWN. 7. CONTACT DUWAMISH TOWERS FACILITIES DEPARTMENT AT 544 -9598 24 HOURS PRIOR TO WORKING ON FIRE PROTECTION SYSTEM. 8. CAUTION! BUILDING FLOOR SLABS ARE PRE - TENSIONED. X -RAY ALL LOCATIONS PRIOR TO DRILLING, PENETRATING OR ANCHORING TO FLOOR SLABS. 9. INSTALLATION OF FIRE PROTECTION SYSTEM SHALL BE IN COMPLIANCE WITH NFPA 13 NATIONAL FIRE PROTECTION ASSOCIATION, FACTORY MUTUAL (FM), INDUSTRIAL RISK INSURERS (IRI) AND LOCAL BUILDING CODES. 10. DO NOT SPACE HANGERS MORE THAN 12'-0" APART, NOT MORE THAN S-0" FROM END OF LINE OR LESS THAN 3 INCHES FROM A SPRINKLER HEAD. 1 1. NOTIFY BOEING FIRE DEPARTMENT PRIOR TO MAKING CONNECTIONS TO EXISTING DRY PIPE FIRE PROTECTION SYSTEM. (655 -7700) COORDINATE ALL REQUIRED SHUT -DOWNS WITH FIRE DEPARTMENT A MINIMUM OF 24 HOURS IN ADVANCE. COMPLY WITH ALL REQUIREMENTS OF FIRE DEPARTMENT. NOTIFY FIRE DEPARTMENT UPON COMPLETION OF WORK. REFERE \CE DRAWI\ GS CO\STRUCTO\ \OTES rj>REMOVE EXISTING SPRINKLER HEADS AND PIPING AS NEEDED TO SUPPORT REMOVAL OF EXISTING AIR CONDITIONER AHU -1A AND INSTALLATION OF NEW UNIT AHU -1B. REINSTALL PIPING AND HEADS WHEN INSALLATION IS COMPLETE ISSUE FOR PERMIT 5285 - 10/9266464 08/05/2010 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DJA DATE 09/28/92 CHECKED MWS ENGINEER JRM CHECKED 5.9 i1 G2 < EY- P LA\ SUBTITLE GARAGE LEVEL PARTIAL PLAN - FIRE SPRINKLERS 10/08/92 TITLE REPLACE CRITICAL COOLING SYSTEM SCALE: NONE CURRENT REVISION 9266456 RECEIVED AUG 09 2010 PERMIT CENTER SYMBOL DATE 09.28.09 SHEET APPROVED BUILDING 11 -0140 0M267 JOB NO. DESIGN / INSTALL HVAC SYSTEM 567893 -00 LM THOMAS WDH 02.12.08 APPROVED MECHANICAL MASTER COL. G— M/12 -18 9266456 COMP N DUWAMISH, WA DWG No. 11- 0140 -0M267 Ts- N Tr 8 M v► 0 0M263 0M262 OM261 0M260 /f/ 0M266 0M265 -\ OM264 OM271/ 0M270 0M269 0M26 0M273 0M27 < EY- P LA\ SUBTITLE GARAGE LEVEL PARTIAL PLAN - FIRE SPRINKLERS 10/08/92 TITLE REPLACE CRITICAL COOLING SYSTEM SCALE: NONE CURRENT REVISION 9266456 RECEIVED AUG 09 2010 PERMIT CENTER SYMBOL DATE 09.28.09 SHEET APPROVED BUILDING 11 -0140 0M267 JOB NO. DESIGN / INSTALL HVAC SYSTEM 567893 -00 LM THOMAS WDH 02.12.08 APPROVED MECHANICAL MASTER COL. G— M/12 -18 9266456 COMP N DUWAMISH, WA DWG No. 11- 0140 -0M267 Ts- N Tr 8 M v► 0 A A.4 B . D 0 EG 2 G.4 LECE\D CE\ERAL \OTES 1 2.6 1 • ALL CONDUIT TO BE 3/4 "GALVANIZED RIGID STEEL UNLESS OTHERWISE NOTED. p� 2.4 ii _ —_ v IN C 2. ALL WIRE TO BE #12 THHN UNLESS OTHERWISE NOTED THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED �� , - - 12.2 �- I 1 411 .. - —__ r \ \ Q • O #4* o ON ALL 208Y/ 120V CIRCUITS: 'A 'PHASE (LEFT BUS IN PANEL) BLACK 'B'PHASE (CENTER BUS IN PANEL) RED 'C'PHASE (RIGHT BUS IN PANEL) BLUE NEUTRAL WHITE GROUND GREEN o ( a _____ ` SEE SHEET M561 ' ' ` •, :NI-- ISOLATED GND GRN /YELLOW DYMO LABEL ALL RECEPTACLES,JUNCTION BOXES, SWITCHES, ETC. 3. WITH CIRCUIT IDENTIFICATION. I -I- � / * • / / \ / \ \ \ \ \ \ 0 4. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 5. FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. • U —� TWISTED SHIELDED PAIR CABLE EXTENDS FROM DDC CONTROLLERS 6 AT BOXES TO ELECTRICAL ROOM AND THEN UP TO LAN CONTROLLER 0 t _ �= �� / / \ \ \ # \ \ • • IN MBC PANEL IN 3rd FLOOR MECHANICAL ROOM. ■ I II SMOKE DETECTOR INTERFACED TO CMCS SYSTEM TO ALARM ON SMOKE DETECTION AND SHUT DOWN SF- OL- G.2 -12 ��..��� ___o�Im11� �i�l REFERSCE DRAWAGS 1 I�I,I I B I,Illpn 31 ■40 1 ,' �� - \ � ` \ / 11-14N-1E210 1ST FLOOR CMCS CONTROLS PARTIAL PLAN ►� '� 1 1 / / �,`���r �, .I► \ 11- 140 -OM17 GARAGE LEVEL HVAC PARTIAL PLAN 2 III � .MMIE Oh YAP! El I. I . 44 .. • 111 ---- 1 I �:- Lag Aw , • ,•• / / / / \ I _ 1 I • 11111Pr .411 -M527 -M528 = M4 IrI � - - 84 -,J g it __ CO\STRUCTO\ \OTES DI ,_fi IIP - i_.IIirTll1 i / / 1 Ali REMOVE EXISTING CONTROLS FOR AIR CONDITIONER AHU -1A AFTER UNIT HAS BEEN SHUT DOWN 11- 0140 -0M17 11- 14 11- 14 / / , I INSTALL NEW WALL CONTROLLER FOR NEW UNIT AHU-1B AND 1:::» CONNECT AFTER NEW UNIT HAS BEEN COMPLETED CONNECT CONTROLS BETWEEN FAN COIL AHU -1B AND FAN cr> COIL COND 1B. REFER TO SHEETS M334 AND M335. REUSE EXISTING '" CONDUIT FOR WIRING ■ _ INSTALL NEW ECONOMIZER STAGE AND CONNECT TO CONTROLS B>. ON NEW AHU -1B. REFER TO SHEETS M334 AND M335. INSTALL NEW 3" CONDUIT FOR WIRING 0 1 ■-- ' X • El ES „---- A C.2 0 T 0 ■ •1 MAR 2 7.; 2011 T 19 0E213 0E212 0E211 0E210 I 11 NM ,_,_,,_/.__ _ OE215 REVIEWED F ®R DE E C 0 COMPLIANC APPROVED 2 6 2010 / I T,RY ° _ LAUB ( .) M 1 0 ....4. 1 1 2. City of Tukwila LDING �u� n D s OE221 0E220 0E219 —� I — I 0E218 o 0E223 \ ISSUE FOR PERMIT 0E222 oo�i1 o�X !!,11 z II ;,,-3) Ii 6 '< EY — P LA \ ����° RECEIVED 1 5285 -10 / 9266464 08/05/2010 .. c: n n- AUG 09 2010 , :: — .. _ _ 5.9 _ SCALE: NONE �,� ss, / PERMIT CENTER SYM 1 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ® g)LA517417EVAW ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN J. BATSCHI DATE 01/10/97 SUBTITLE GARAGE LEVEL HVAC CONTROLS PARTIAL PLAN CURRENT REVISION 9266456 SYMBOL B DATE 09.28.09 CHECKED - A B REPLACED BORDER DESIGN / INSTALL HVAC SYSTEM 567893 -00 REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS LM THOMAS LM THOMAS WDH WDH 01., 5.08 02.12.08 09.28.09 SHEET 0 E217 q 1 �,V ENGINEER TITLE REPLACE CRITICAL COOLING SYSTEM — BUILDING 11-0140 ELECTRICAL MASTER COL. G- N/12 -18 DUWAMISH, WA APPROVED BY DEPT. DATE CHECKED JOB NO. 9266456 COMP N0. APPROVED APPROVED DWG Na 11- 0140 -0E217 oo 8 N x 8 a 0 C1 o, 0 Cs CvPTER ROOv AIR CO\DTO\ER SC-E3ULE - U\TS O\ STA\8Y POWER U \LESS \OTED MARK LOCATION RATINGS A \) HEAT PvP POWER MANUFACTURER AND MODEL NOTES CFM SENSIBLE COOLING TOTAL COOLING RET. AIR LDB /LWB REJECTION FLOW CONDITIONS FAN +COMPRESS REHEAT +HUM VOLTS AMPS VOLTS AMPS NET LDB /LWB REJECTION FLOW CONDITIONS FAN COMPRESSOR VOLTS AMPS VOLTS AMPS AC-1S 1 SOUTH MECH RM OFFICE A/C 32000 929 MBTUH CAC -1S-D4.5 1 SOUTH DATA CLOSET-11D4 DATA ROOM BACK UP AIR CONDTIONER 1800 CFM (3/4 3 HP) ) 33.1 MBTUH 38.3 MBTUH RA AT 72F/ / 50 %RH CT-1S 3.8 GPM 85.0/95.0 460 VAC 3 PH 1.4 RLA 460 VAC 3 PH 19.6 FLA WITH ELECTRIC REHEAT & INFRARED HUMIDIFIER, NON —FUSED DISCONNECT SWITCH, COMPRESSOR CRANKCASE HEATER AND HIGH HEAD OPTION WITH ADVANCED MICROPROCESSOR CONTROL WITH GRAPHICS, CONDENSATE PUMP, SEISMIC RATED 18" HIGH FLOOR STAND, SMOKE DETECTOR, AND MODBUS INTERFACE CARD OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 AC -3S 3 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -01 -01 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -4S 4 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT-1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -02 -01 S/N 21384 -02 -02 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -5S 5 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT-1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL AC -1N 1 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX- 952 -GXL S/N 21384 -03 -01 R -22, 86 LBS, CIR 1, 73 LBS CIR 2 AC -2N 2 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT-1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX- 952 -GXL S/N 21384 -05 -01 R -22, 86 LBS, CIR 1, 73 LBS CIR 2 AC -3N . 3 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT-1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -06 -01 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -4N 4 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -01 -02 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -5N 5 NORTH MECH RM OFFICE A/C 30000 • 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -01 -03 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -6N 1 CAFE MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT-1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX- 802 -GXL S/N 21736 -01 -01 R -22, 78 LBS, CIR 1, 65 LBS CIR 2 AC -6S 4TH FLR ROOM 43J4 COMP LAB AC 990 - -- 30 MBTUH - -- AC -6S - -- 75.0/95.0 115/1 2.0 208/230/1 20 MITSUBISHI PK3OFK1 INDOOR UNIT MITSUBISHI PU3OEK OUTDOOR UNIT AC- 1N -F10 1ST FLR ROOM 11F9 VIDEO SERVER ROOM 1320 26.4 MBTUH 32.1 MBTUH 72F -50RH AC- ON -M16 - -- 72.0/95.0 208/230/1 2.2 460/3 6.4 LIEBERT DATAMATE LIEBERT DATAMATE PFH037A -AL3 DME037E -PC3 INDOOR UNIT OUTDOOR UNIT HP -1 GARAGE LEVEL BATTERY ROOM 300 11.3 MBTUH 10.7 MBTUH HEATING 53.7/51.3 AIR TO AIR -- -- -- -- -- -- CARRIER MODEL 52SQA312 - - -3 UPS ROOM HP -2 GARAGE LEVEL MISC EQUIPMENT 320 13.1 12.0 MBTUH 53.7/51.3 AIR TO AIR '1 LEGE\ J GEC ERN_ PUMPS AND DIFFUSER SCHEDULES TRANSFERRED TO SHEET M2g UNIT REMOVED FROM SERVICE SEE SHEETS 11-14L-1M10 AND 11-140-0M12 FOR LOCATIONS OF THESE UNITS UNIT ON STANDBY POWER DURING UTILITY OUTAGES - REFERENCE JOBS 150687 -01 AND 150686 -00 UNIT ON NORMAL UTILITY POWER - UNIT WILL NOT RUN DURING OUTAGES AIR CO` D A \) HEAT PvP SC-E3ULE MARK LOCATION SERVICE RATINGS POWER MANUFACTURER AND MODEL NOTES ADDITIONAL INFORMATION REFRIGERANT AND QTY CFM SENSIBLE COOLING TOTAL COOLING NET LDB /LWB REJECTION FLOW CONDITIONS FAN COMPRESSOR VOLTS AMPS VOLTS AMPS AC-1S 1 SOUTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT-1S CT -1S 272 GPM 272 GPM 85.0/95.0 85.0/95.0 460/3 460/3 54.0 54.0 460/3 460/3 60.5x2 60.5x2 MAMMOTH WX- 952 -GXL MAMMOTH WX- 952 -GXL S/N 21384 -03 -01 S/N 21384 -06 -01 R -22, 86 LBS, CIR 1, 73 LBS CIR 2 R -22, 86 LBS, CIR 1, 73 LBS CIR 2 AC -2S 2 SOUTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 AC -3S 3 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -01 -01 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -4S 4 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT-1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -02 -01 S/N 21384 -02 -02 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -5S 5 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT-1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL AC -1N 1 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX- 952 -GXL S/N 21384 -03 -01 R -22, 86 LBS, CIR 1, 73 LBS CIR 2 AC -2N 2 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT-1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX- 952 -GXL S/N 21384 -05 -01 R -22, 86 LBS, CIR 1, 73 LBS CIR 2 AC -3N . 3 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT-1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -06 -01 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -4N 4 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -01 -02 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -5N 5 NORTH MECH RM OFFICE A/C 30000 • 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX- 802 -GXL S/N 21384 -01 -03 R -22, 71 LBS, CIR 1, 57 LBS CIR 2 AC -6N 1 CAFE MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT-1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX- 802 -GXL S/N 21736 -01 -01 R -22, 78 LBS, CIR 1, 65 LBS CIR 2 AC -6S 4TH FLR ROOM 43J4 COMP LAB AC 990 - -- 30 MBTUH - -- AC -6S - -- 75.0/95.0 115/1 2.0 208/230/1 20 MITSUBISHI PK3OFK1 INDOOR UNIT MITSUBISHI PU3OEK OUTDOOR UNIT AC- 1N -F10 1ST FLR ROOM 11F9 VIDEO SERVER ROOM 1320 26.4 MBTUH 32.1 MBTUH 72F -50RH AC- ON -M16 - -- 72.0/95.0 208/230/1 2.2 460/3 6.4 LIEBERT DATAMATE LIEBERT DATAMATE PFH037A -AL3 DME037E -PC3 INDOOR UNIT OUTDOOR UNIT HP -1 GARAGE LEVEL BATTERY ROOM 300 11.3 MBTUH 10.7 MBTUH HEATING 53.7/51.3 AIR TO AIR -- -- -- -- -- -- CARRIER MODEL 52SQA312 - - -3 UPS ROOM HP -2 GARAGE LEVEL MISC EQUIPMENT 320 13.1 12.0 MBTUH 53.7/51.3 AIR TO AIR -- -- -- -- -- -- CARRIER MODEL UPS ROOM STORAGE MBTUH HEATING 52SQB314 - - -3 AHU -1A GARAGE LEVEL UPS ELECTRONICS 6,000 163 MBTUH 12.0 MBTUH 53.7/51.3 AIR TO AIR 8,800 -- -- -- 460/3 -- CARRIER MODEL 40RR016 AHU FAN COIL WT 825 LBS CFM HEATING SPLIT CFM AND 38AED16 CONDENSER IF UPS ROOM AHU -1B GARAGE LEVEL UPS ELECTRONICS 6,000 CFM 136.9 MBTUH 162.6 MBTUH 58.9/58.6 AIR TO AIR -- 95F DB 460 / 3 PH 6.0 460 / 3 PH 20 CARRIER MODEL 40RUA INDOOR UNIT WITH 38 AUZ OUTDOOR UNIT. ARI RATED EER 11.0 REPLACED UNIT AHU -1 AND ADDED ECONOMIZER STAGE WITH INTEGRAL FILTER BANK FOR 2" DISPOSABLE FILTERS, 713 LBS FAN COIL, 340 LBS R -410A REFRIGERANT, 2.5 LBS PER CIRCUIT, 2 CIRCUITS IN 40RUA FAN COIL, 8 LBS IN 38AU i7UPS ROOM CJ NMI NMI ■11111I NMI NMI NMI NMI ■1110I NMI ■11111111/ NMI ■11111I NISI NMI NUM/ 'MOW NMI `MOW 'MOW NMI NMI NMI NMI/ NMI NMI 'MOW ■IIMII NMI ■IIIIII NMI NMI NMI' NMI ■11111I NMI NMI 'MOW NMI ■11111I i n UST " • III 1 • " Mlo- 111 REFERE \CE DRAW\GS REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 6 2010 City of Tukwila BUILDING DIVISION RECEIVED AUG 09 2010 PERMIT CENTER ISSUE FOR PERMIT 5285 -10 / 9266464 08/05/2010 Cooling System \Mechanical_Permit Drawings \m2a.dwg, Model, 8/6/2010 10:08:37 AM, SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A CONDENSER WATER INTERTIE J# 989082 FSI 12.21.98 F CAS OPS CENTER MECH 150689 -00 LM THOMAS 07/27/06 B BUILD CONFERENCE ROOM N.4 710060 -00 LM THOMAS G REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS WDH 09.28.09 C RECONFIO CR TO TRN ROOM 71277300 LM THOMAS D CAS — OPERATIONS CENTER 150550 -00 LM THOMAS WDH 09/08/05 E GOLD CARE OFFICE EXPANSION 150686 -00 LM THOMAS WDB 04/20/06 Q� BOE /NG® c�— ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN BDR CHECKED RSN ENGINEER MRS CHECKED DATE 12.14.98 12.15.98 12.11.98 SUBTITLE HVAC EQUIPMENT SCHEDULES CURRENT REVISION 9266456 SYMBOL DATE 09.28.09 APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEM BUILDING 11 -14 MECHANICAL MASTER DUWAMISH SHEET M2A JOB NO, 9266456 COMP NO. r1 5/14 DWG NO. 1 1 -14 -M2A th a 0 Io E TYPICAL CONTROL WIRING SCHEMATIC 6 -10T 208/230V SNGL 115V FIELD -r: =- - • • -1 SUPPLY ITT BLN FLOP NON- POEERED: GND- - ' - - • CONVENIENCE! OUTLET 208/230V BUSSMAN FM0.1 1 FLOP CONVENIENCE OUTLET 115V = RED• --� rus 1.-YEL-2! ,GAA� FU/ p- BLN -" =. II : RED 208 /230V TRANI GRA GFI -CO • /GIN- YEL • GRN•YEII Co SECONDARY St 1/11 LN 1 ■ ■ ■ ■ ■ ■ ' JUMPER ID ail _ FIELD - _ PO19 SUPPLY 10 COOL -0 AUTO -0 0 HEAT - 0 0 1.12o F 3 COOL _ 4 AUTO 0 ■ HEAT 0 0 ■ SEE NOTE #3 9 •TCl• CC ON CC AUTO m TH1 TH2 . . AHA AHA 4D G.. BLK BLU TEL CONNECTION BOARD(TB) LLSV 2 3Y2 4 W1 C ■_ ■ MIN ■MEIN ■=MI SPEED CONTROL! • • COIL TEMP SENSOR ■ BLK BLK RED } BLK • BLK 'VVj CH 1 • I-- GR•YF m tp ea 7`111P AMEM1. /LUG POS TO YEL ( SEE NOTE 7 OO -IK OT CAP 1 CADM T10----BLK T20 -BLU T30--YEL 4 AMP INTERNAL TO TRAN RED BLK BLK BLK YEL E{T}- BRN YEL 5W2 60 7_ BLK YEL BRN GR -YEL /// RED YEL BRN CADM LPS HPS BLU 80 X BRN OR -OY CADM LO PO BLK O BRN VIO COMPONENT ARRANGEMENT BRN OFM 1 OFM 2 CONNECTION BOARD TERM BOARD C COMP TERM C BOARD TRAN C CADM C CONTROL BOX (91)O?V09 NOI103NNO3 1E 6© 70 80 X 9 A2 CAP CADM �T1 DATAO PORT CD OT2 UT 3 FIELD CONTROL WIRING 4f2s FIELD SPLICE -- MARKED WIRE TERMINAL(MARKED) O TERMINAL(UNMARKED) TERMINAL BLOCK • SPLICE FACTORY WIRING FIELD CONTROL WIRING FIELD POWER WIRING ACCESSORY OR OPTIONAL WIRING LEGEND TO INDICATE COMMON - POTENTIAL'ONLY, NOT TO REPRESENT WIRING AHA C CAP CC CH CADM COMP EQUIP GR HPS IFC LLSV LPS OFM OT TB TC TH TRAN ADJUSTABLE HEAT ANTICIPATOR CONTACTOR, COMPRESSOR CAPACITOR COOLING COMPENSATOR CRANKCASE HEATER COMFORT ALERT - DIAGNOSTICS MODULE COMPRESSOR MOTOR EOUIPMENT GROUND HIGH PRESSURE SWITCH INDOOR FAN CONTACTOR LIOUID LINE SOLENOID VALVE LOW PRESSURE SWITCH OUTDOOR FAN MOTOR OUADRUPLE TERMINAL TERMINAL BLOCK THERMOSTAT - COOLING THERMOSTAT-HEATING TRANSFORMER O cod O 0 TB TRAN © 24 208 230 ) FIELD WIRING 1 DISCONNECT PER NEC I NOTES: 1. IF ANY OF THE ORIGINAL WIRE FURNISHED MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 90 °C WIRE OR ITS EOUIVALENT. 2. THERMOSTAT: HHO7AT170,172,174 8 P272 -2783 SUBBASE: HH93AZ176,178 8 P272 - 1882,1883 OR: HH93AZ177 8 179 3. SEALED VA FOR IFC 8 LLSV IS NOT TO EXCEED 22. 4. USE COPPER CONDUCTORS ONLY. 5. THREE PHASE MOTORS ARE PROTECTED UNDER PRIMARY SINGLE PHASING CONDITIONS. 6. TRAN IS WIRED FOR 230V UNIT. IF UNIT IS TO BE RUN WITH 208V POWER SUPPLY, DISCONNECT BLK WIRE FROM 230V TAP AND CONNECT TO 208V TAP. 7. ON UNITS WITH SPEED CONTROL, THESE WIRES ARE TO BE CONNECTED TO BLK WIRES FROM SPEED CONTROL MODULE. 009238 11 - 140.0 0130,0 >0 120.0 2 100.0 m W oZ 90.00 J > 80.00 38AUZ -14 CHARGING CHART PURON ALL CONDENSER FANS OPERATING 0 0 0 0 0 J 70.00 W =.Q 60.00 w cc= 50.00 W 38AUZ -14 TABLEAU DE CHARGE PURON TOUTES LES SOUFFLERIES DE CONDENSATION EN FONCTIONNEMENT 140.00 190.00 240.00 290.00 340.00 390.00 440.00 490.00 540.00 590.00 PRESSURE AT LIQUID VALVE (PSIG) PRESSION A LA VANNE DE LIOUIDE (PSIG) SCHEMATIC 6 -10T 208/230V SNGL !MP E R 1 ▪ 111 MMMI Fig. 19 - 38AUZ *14 Charging Chart - GR -YEL Z EOUIP GR FIELD POWER SUPPLY BLK -YEL -BLU CONNECTION BOARD(TB) 111■1a■...■■..■■.. IT • SPEED CONTROL . SENSOR • COIL TEMP T T i t i RED .J m BLK BLK 1 POS TB W /LUG YEL O� OT CAP 1 CADM T1 T2 T30 BLK BLK YEL BLK YEL BRN BLK YEL BRN CH BLK YEL BLU L GR -YEL /// 4 AMP INTERNAL TO TRAN RED COOL ATUO 0 HEAT �F 3 �w COOL d_ 4 TH1 1 • • AUTO 0 ■ HEAT 1 ■ SEE NOTE #3 0 AHA 1 ■ MEM■ • I • 1 I . -- Fig. 20 - 38AU Wiring Diagram 17 OFM 1 OFM 2 CONNECTION BOARD TERM BOARD C COMP TERM BOARD C TRAN C CADM C (iCARACE LEVEL SOUTH JPS ELE:,TRO CARRIER 38AU FA\ M528 M334 \ICS ROC COIL CO\ v T CO \TROL ROLS DIAGRA v S LEGE\D CE\ERAL \JTES 1) SEE DRAWING 1 1- 14 -M335 FOR CARRIER MODEL 40RU AIR HANDLER SCHEMATIC REFERE \CE 3RAW\GS 11- 14 -M2A 1 1 - 14 -M2G 1 1- 14 -M528 HVAC EQUIPMENT SCHEDULES HVAC COMPONENT SCHEDULES UPS INSTALLATION - HVAC 1 CO\STRUCTO\ \ TES ) CONNECT AHU -1 B, CARRIER MODEL 40RUA AIR HANDLER WITH CONDENSER 1 B, CARRIER MODEL 38AUZ CONDENSER WITH TYPE ACR COPPER TUBING WITH BRAZED JOINTS. 2) CONNECT AHU -1 B, CARRIER MODEL 40RUA AIR HANDLER WITH CONDENSER 1 B, CARRIER MODEL 38AUZ CONDENSER ELECTRICAL WIRING PER SCHEMATICS PROVIDED HERE AND SHEETS M335, M568, AND M570 MOUNT NEW ECONOMIZER STAGE BETWEEEN NEW FAN COIL AND RETURN AIR DUCT AND CONNECT FOR ECONOMIZER MODE OPERATION. 3) CHARGE REFRIGERANT TUBING SYSTEM WITH R410 REFRIGERANT AS NOTED IN START UP PROCEDURE MAR 2 7, 2011 t(° 112 ISSUE FOR PERMIT 5285 -10 / 9266464 08/05/2010 RECEIVED AUG 09 2010 PERMIT CENTER e;LA9747.4EZAW ® - ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN LM THOMAS DATE 09.18.09 CHECKED SUBTITLE HVAC DETAILS UPS ELECTRONICS ROOM CURRENT REVISION 9266456 SYMBOL DATE 09.28.09 APPROVED BY DEPT. DATE ENGINEER LM THOMAS 09.18.09 CHECKED APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEN MECHANICAL MASTER BUILDING 11 -14 COL. x-x/x-x DUWAMISH, WA SHEET M334 (pA3, JOB NO. 9266456 COMP NO. DWG NO. 11 -14 -M334 BY APPROVED DATE SYM REVISION BY APPROVED DATE SYM REVISION - REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS WDH 09.28.09 e;LA9747.4EZAW ® - ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN LM THOMAS DATE 09.18.09 CHECKED SUBTITLE HVAC DETAILS UPS ELECTRONICS ROOM CURRENT REVISION 9266456 SYMBOL DATE 09.28.09 APPROVED BY DEPT. DATE ENGINEER LM THOMAS 09.18.09 CHECKED APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEN MECHANICAL MASTER BUILDING 11 -14 COL. x-x/x-x DUWAMISH, WA SHEET M334 (pA3, JOB NO. 9266456 COMP NO. DWG NO. 11 -14 -M334 TYPICAL CONTROL WIRING SCHEMATIC DISCONNECT FIELD POWER HEATER CONTROL BOX TERMINAL BLOCK 40RU CONTROL BOX TERMINAL BLOCK TB1 r 1 L —t TB1 SUPPLY — _ L3 3 -Ph ONLY HC1 � H° EQUIP GND FIELD POWER WIRING L_ HC1 0 I� 0 CIRCUIT BREAKER (5 HP AND LARGER) 0 - - 1 , 5 0 - - 0 0 - HEATER CONTROL BOX TERMINAL BLOCK TB2 WHT WHT R - THERMOSTAT 38 I FC CONNECT TO 24 VAC AT CONDENSING UNIT rfGARAGE LEVEL SOTH JPS ELECTRO\C M528 M335 CARRIER 38A., FA\ C3 S R00 L C0\ v BLK BLK BLK HTR1 IFM UNIT WIRING 1 C09050 SEPARATE 1.0) PERMIT AND APPROVAL REQUIRED C3\ TROLS TROL ]IAGRA v S NOTES ON CHARGING SYSTEM WITH R410 UNIT START UP PRESSURE —TEST ALL JOINTS FROM OUTDOOR UNIT CONNECTIONS OVER TO THE EVAPORATOR COIL, USING NITROGEN AS PRESSURE AND WITH SOAP AND — BUBBLES. WHEN PRESSURE — TESTING IS COMPLETED, REMOVE THE NITROGEN SOURCE AT THE OUTDOOR UNIT SERVICE VALVES AND RE— INSTALL THE TWO SCHRADER VALVE CORES. TORQUE THE CORES TO 2 -3 IN —LBS (23 -34 N —CM). EVACUATION /DEHYDRATION — EVACUATE AND DEHYDRATE THE CONNECTED REFRIGERATION SYSTEM (EXCLUDING THE 38AU UNIT) TO 500 MICRONS USING A TWO —STAGE VACUUM PUMP ATTACHED TO THE SERVICE PORTS OUTSIDE THE 38AU SERVICE VALVES, FOLLOWING DESCRIPTION IN GTAC II, MODULE 4, SYSTEM DEHYDRATION. TURN ON CRANKCASE HEATER —TURN ON THE CRANKCASE HEATER FOR 24 HOURS BEFORE STARTING THE UNIT TO BE SURE ALL THE REFRIGERANT IS OUT OF THE OIL. TO ENERGIZE THE CRANKCASE HEATER, PROCEED AS FOLLOWS: 1. SET THE SPACE THERMOSTAT SET POINT ABOVE THE SPACE TEMPERATURE SO THERE IS NO DEMAND FOR COOLING. 2. CLOSE THE FIELD DISCONNECT. PRELIMINARY CHARGE — BEFORE STARTING THE UNIT, CHARGE R -410A LIQUID REFRIGERANT INTO THE HIGH SIDE OF THE SYSTEM THROUGH THE LIQUID SERVICE VALVE. THE AMOUNT OF REFRIGERANT ADDED MUST BE AT LEAST 80% OF THE OPERATING CHARGE LISTED IN THE PHYSICAL DATA TABLE (TABLES 1A AND 1B, PAGES 4 AND 5) LESS THE FACTORY CHARGE QUANTITY (IF FACTORY SHIPPING CHARGE HAS NOT BEEN REMOVED). ALLOW HIGH AND LOW SIDE PRESSURES TO EQUALIZE. IF PRESSURES DO NOT EQUALIZE READILY, CHARGE R -410A VAPOR (USING SPECIAL SERVICE MANIFOLD WITH EXPANSION DEVICE) INTO THE SUCTION LINE SERVICE PORT FOR THE LOW SIDE OF SYSTEM TO ASSURE CHARGE IN THE EVAPORATOR. REFER TO GTAC II, MODULE 5, CHARGING, RECOVER, RECYCLING, AND RECLAMATION FOR LIQUID CHARGING PROCEDURES. NOTE: THE 38AUZ UNITS ARE FACTORY CHARGED WITH THE REQUIRED AMOUNT OF OIL. IF RECHARGING IN REQUIRED, USE EMKARATE RL 32 -3MAF FOR THE 38AUZ UNITS. COMPRESSOR ROTATION —ON 3 —PHASE UNITS WITH SCROLL COMPRESSORS, IT IS IMPORTANT TO BE CERTAIN THAT THE COMPRESSOR IS ROTATING IN THE PROPER DIRECTION. TO DETERMINE WHETHER OR NOT COMPRESSOR IS ROTATING IN THE PROPER DIRECTION: 1. CONNECT SERVICE GAGES TO THE SUCTION AND LIQUID PRESSURE FITTINGS. 2. ENERGIZE THE COMPRESSOR. 3. THE SUCTION PRESSURE SHOULD DROP AND THE LIQUID PRESSURE SHOULD RISE, AS IS NORMAL ON ANY START —UP. IF THE SUCTION PRESSURE DOES NOT DROP AND THE LIQUID PRESSURE DOES NOT RISE TO NORMAL LEVELS: 1. TURN OFF POWER TO THE UNIT, TAG DISCONNECT. 2. REVERSE ANY TWO OF THE UNIT POWER LEADS. 3. REAPPLY POWER TO THE COMPRESSOR, VERIFY CORRECT PRESSURES. THE SUCTION AND LIQUID PRESSURE LEVELS SHOULD NOW MOVE TO THEIR NORMAL START —UP LEVELS. LEGE \J CE\ERAL \OTES 1) SEE DRAWING 1 1- 14 —M334 FOR CARRIER MODEL 38 AUZ CONDENSER SCHEMATIC REFEREE CE IRAWI\GS 11- 14 —M2A 1 1 — 14 —M2G 11-14—M528 HVAC EQUIPMENT SCHEDULES HVAC COMPONENT SCHEDULES UPS INSTALLATION — HVAC C0 \STRUCTIO\ COTES 1) CONNECT AHU -1 B, CARRIER MODEL 4ORUA AIR HANDLER WITH CONDENSER 1B, CARRIER MODEL 38AUZ CONDENSER WITH TYPE ACR COPPER TUBING WITH BRAZED JOINTS. 2) CONNECT AHU -1 B, CARRIER MODEL 4ORUA AIR HANDLER WITH CONDENSER 1B, CARRIER MODEL 38AUZ CONDENSER ELECTRICAL WIRING PER SCHEMATICS PROVIDED HERE AND SHEETS M3.34, M568 AND M570. MOUNT NEW ECONOMIZER STAGE BETWEEEN NEW FAN COIL AND RETURN AIR DUCT AND CONNECT FOR ECONOMIZER MODE OPERATION. 3) CHARGE REFRIGERANT TUBING SYSTEM WITH R410 REFRIGERANT AS NOTED IN START UP PROCEDURE fi MAR 2 7 201 M10- 1 1z ISSUE FOR PERMIT 5285 -10 / 9266464 08/05/2010 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 6 2010 City of Tukwila BUILDING DIVISION RECEIVED AUG 09 2010 PERMIT CENTER Permit_Drawings\M335.DWG, Model, 8/6/2010 10:08:58 AM, X a a ub N g 0 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS WDH 09.28.09 QiBOE /NG° c�— ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED APPROVED APPROVED DATE 09.18.09 SUBTITLE HVAC DETAILS UPS ELECTRONICS ROOM CURRENT REVISION 9266456 SYMBOL DATE 09.28.09 09.18.09 TITLE REPLACE CRITICAL COOLING SYSTEM BUILDING 11 -14 MECHANICAL MASTER COL. X —X /X —X DUWAMISH, WA SHEET M335 JOB NO. DWG NO. COMP NO. 9266456 11 -14 —M335 EQUIPV E \T \OYES; SE \ERAL \OTES SELF - CONTAINED GRAVITY- OPERATED EMERGENCY EYE WASH. UNIT SHALL BE A HAWS, MODEL 7500 EYE WASH WITH BACTERIOSTATIC ADDITIVE, OR EQUAL. INSTALL AS PER CODE AND MANUFACTURERS RECOMENDATIONS. SELF - CONTAINED EMERGENCY EYE WASH -� 8"x8" EG 150 CFM CONDENSATE PUMP WITH RECEIVER, HARTELL MODEL HAR-KL-151UL, RATED AT 30 GPH AT 14' HD. CONNECT DRAINS FROM BOTH HP -1 AND HP -2 TO THE RECEIVER. PROVIDE AN 18 GA. STEEL COVER, ATTACHED TO THE FLOOR WITH 3/8" HINGES, TO ALLOW SERVICE ACCESS. CONDENSATE PUMP WITH RECEIVER, HARTELL MODEL HAR-KT-151UL, RATED AT 30 GPH AT 14' HD. CONNECT CONDENSATE FROM AHU -1 TO THE RECEIVER. MOUNT PUMP FROM WALL WHERE SHOWN. 1. FOR INFORMATION ON MECHANICAL EQUIPMENT, SEE SCHEDULES ON DRAWING 11 -14 -M2A AND M2G 2. CAUTION! BUILDING FLOOR SLABS ARE PRE - TENSIONED. X -RAY ALL LOCATIONS PRIOR TO DRILLING, PENETRATING OR ANCHORING TO FLOOR SLABS. 3. PRE- FILTER SECTION SHALL CONSIST OF (4) 24" X 24" X 1" FARR 30/30 FILTERS, OR EQUAL, MOUNTED IN A V FRAME IN AHU -1'S RETURN DUCT. 4. 16 X 16 SUPPLY REGISTERS ARE TO BE INITIALLY SET TO PROVIDE 1000 CFM ON EACH OF (3) REG. S.W. OF COLUMN LINE 20, AND 500 CFM ON EACH OF (3) REG. N.E. OF COLUMN LINE 20. INSTALLATION HAS BEEN SIZED FOR ADDITIONAL LOADS IN THE FUTURE. 10 "x6" .\--10"x 6" EG 200 CFM BATTERY ROOM O.B. BALANCING DAMPER (TYP.) - UPS EQUIPMENT ROOM (6) 16" x 16" SUP. REG. WITH OBD 500 CFM 1000 CFM CO \STRUCTIO\ \OTES MISCELLANEOUS EQUIPMENT ROOM 34 "x20" UAL 500 CFM 18" x 10" 48 "x26" OUTSIDE AIR OPENING WITH 1/8" INSECT SCREEN (IN CLOSED AND LOCKED POSITION) 48 "x34" RETURN GRILLE 6' -10" AFF 18" x 10" 8 "x6" GRILLE 500 CFM 6' -10" AFF (3) 8"x6" GRILLES 48 "x34 "x4 ", 16 GA GALV. STEEL PLENUM FOR CONTROL DAMPER INSTALLATION (TYP.) SOUND LIN DUCTWORK (TYP) (2) 48 "x34" CONTROL DAMPER WITH 1/8" INSECT SCREEN (IN CLOSED AND LOCKED POSITION) BUILDING HVAC TECH TO TAKE AIR CONDITIONING SYSTEM OFF LINE PRIOR TO START OFF REMOVAL OF INDOOR UNIT AHU -1A AND CONDENSOR 1A. BUILDING HVAC TECH TO REMOVE EXISTING CHARGE OF REFRIGERANT IN AIR CONDITIONER UNIT AHU -1A AND CONDENSOR 1A. CHARGE TO RECOVERED AND SENT TO PLANT 2 REFRIGERANT RECYCLING AFTER REFRIGERANT HAS BEEN REMOVED FROM SYSTEM, REMOVE EXISTING COPPER TUBING CONNECTING INDOOR AND OUTDOOR UNITS. NEW UNIT TO BE .INSTALLED USES SYNTHETIC LUBRICANT WHICH IS NOT COMPATIBLE WITH EXISTING LINES WITHOUT CLEANING. DISCONNECT LOCAL CONTROLS AND POWER FROM AHU -1A DISCONNECT FAN COIL FROM DUCTWORK AND LOWER TO GROUND. REMOVE FIRE SPRINKLERS AND PIPING TO PROVIDE WORKING CLEARANCE REMOVE OUTDOOR UNIT FROM CONCRETE HOUSEKEEPING PAD. SEND FAN COIL AND OUTDOOR UNIT TO SURPLUS SALES CONDENSATE DOWN TO 6" ABOVE GRADE 1 3/8" 0.D. SUCTION, 5/8" O.D. LIQUID / REFRIGERANT PIPING 24 "x26" FILTER ACCESS DOOR PRE - FILTER SECTION (FILTER REMOVED PER BOEING REQUEST) 76x28 76x34 REFERE \CE 3RAW\CS 11 -14 -M2A HVAC EQUIPMENT SCHEDULES 11- 14 -M2G HVAC EQUIPMENT SCHEDULES SPRING TYPE VIBRATION MOUNTS DIRECTLY MOUNTED TO SLAB (6 PLACES) U.P.S. ROOM PLAN DETAIL SCALE: 1/4"= 1 ' -0" OM 17 M528 34x76 SPRINKLER PIPING (REF) FIRST FLOOR MAR 272011 1/4" COND. PIPE EXTERIOR WALL 6' -4" TO OF FAN DOORWAY SEE COVER PLATE DETAIL M52 CONDENSATE PUMP DOORWAY PARKING GARAGE FLOOR COVER PLATE DETAIL- SCALE: NONE M5 8�M 28 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 6 2010 TERMINATE CONDENSATE PIPE 6" ABOVE GRADE CONDENSATE PUMP WITH COVER COLUMN H /20 SECTIO\ SCALE: 1/4"=1 0" M528 M528 ISSUE FOR PERMIT 5285 - 1019266464 0810512010 16 11 KEY PLAN REVISION APPROVED REVISION APPROVED A 1 AS -BUILT 570590 -001 R 1 REMOVAL - REPLACE CRITICAL COOLING SYS 9266456 WILSON &ASS LM THOMAS 09/30/93 09.28.09 Qi BOE /NG® - ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT, DRAWN ERG /EISI CHECKED DATE 01/14/93 SUBTITLE ENGINEER MAI /EISI CHECKED TITLE UPS INSTALLATION - HVAC CURRENT REVISION 9266456 SYMBOL 09.28.09 SHEET REMOVAL- REPLACE CRITICAL COOLING SYSTEM APPROVED BUILDING 11 -014 M528R JOB NO. 9266456 APPROVED MECHANICAL MASTER COL. G- H/20 -21 DUWAMISH, WA DWG NO. 11- 014 -M528R 4. SELF - CONTAINED EMERGENCY EYE WASH EF 12 "x8" 48 456 8 "x8" 10 "x6" t 10"x6" EG 200 CFM MISCELLANEOUS EQUIPMENT ROOM 1 co moo U7 CONDENSATE DOWN TO 6" ABOVE GRADE r L (2) 8 X DAMPER`. 8 "x6" GRILLE 6 8 "x8" EG 150 CFM BACKDF∎ J DUCTIt BATTERY ROOM FT ORK 8 "x6" O.B. BALANCING DAMPER (TYP.) ;34%10" 34 "x20" 18" x 1C 1000 CFM UPS EQUIPMENT ROOM / 500 CFM (6) 16" x 16" SUP. REG. WITH OBD 48 "x34 "x4 ", 16 GA GALV. STEEL PLENUM FOR CONTROL DAMPER INSTALLATION (TYP.) I 3 500 48 1000 FM GRI a AFF 34" RETURN LE 6' -10" 6000 CFM . I8" x 10" a 48 1000 FM GRI a AFF 34" RETURN LE 6' -10" 6000 CFM 1 000 FM 48 "x34" RELIEF GRILLE 6' -10" AFF 48 "x26" OUTSIDE AIR OPENING WITH 1/8" INSECT SCREEN WITH MANUAL QUADRANT TURNING VANES (TYP) -SOUND LINED DUCTWORK (TYP) (2) 48 "x34" CONTROL DAMPER WITH 1/8" INSECT SCREEN (IN CLOSED AND LOCKED POSITION) 48 "x20" (3) 8'x6" GRILLES 2 "COND. 30� 1 3/8" 0.D. SUCTION, 1/2" 0.D. LIQUID REFRIGERANT PIPING 1/4" 0.D. CONDENSATE PIPING (SLOPE 1 /4 " /FT.) 1 "COND. 2 cu If) BACKUP AC UNIT FOR BATTERY ROOK FLOOR PAN 4T TOP OF COLUMN o (U 48 "x26" 48 "x20" IIt 4 J EXISTING ANCHO S FOR lit" �� 2 AHU 1A 6 PLACES e 3 54 12 55 0 w -I . . E8" x 10" 1, 1 1 000 FM 48 "x34" RELIEF GRILLE 6' -10" AFF 48 "x26" OUTSIDE AIR OPENING WITH 1/8" INSECT SCREEN WITH MANUAL QUADRANT TURNING VANES (TYP) -SOUND LINED DUCTWORK (TYP) (2) 48 "x34" CONTROL DAMPER WITH 1/8" INSECT SCREEN (IN CLOSED AND LOCKED POSITION) 48 "x20" (3) 8'x6" GRILLES 2 "COND. 30� 1 3/8" 0.D. SUCTION, 1/2" 0.D. LIQUID REFRIGERANT PIPING 1/4" 0.D. CONDENSATE PIPING (SLOPE 1 /4 " /FT.) 1 "COND. 2 cu If) BACKUP AC UNIT FOR BATTERY ROOK FLOOR PAN 4T TOP OF COLUMN o (U 48 "x26" 48 "x20" IIt 4 J EXISTING ANCHO S FOR lit" �� 2 AHU 1A 6 PLACES e 3 54 12 55 0 w -I . I '` 1, 1 1 Nr 00 t D -' 0 - 0 N -� x D -', I . -/ - '/ (U V.:1 1 U) N 1 1141,, - -tom U.P.S. ROOM P -TA1 L 1 SCALE: 1/4"=1 -0" 0M 17 M528 20 (e, EXTERIOR WALL 6' -4" TO CL OF FAN 4 °4 ° 4 FLOOR PAN AT TOP OF COLUMN TERMINATE CONDENSATE PIPE 6" ABOVE GRADE 04 1/4" COND. PIPE DOORWAY CONDENSATE PUMP WITH COVER ° :4 SEE COVER PLATE DETAIL M528 M528 SECTIO\ DOORWAY SCALE: 1/4"= - 0" M528 I M528 L') SPRINKLER PIPING (REF) 4 ° 4/14 I - - A� M528 M528 CARRIER PROVIDED ECONOMIZER STAGE CAECOMZROO2A00 ST FLOOR 24 CONDENSA E PUMP 26 COLUMN H /20 24 "x72 "x4" FILTER FRAME MOUNTED ON KU ECONOMIZER INLET N In co PARKING GARAGE FLOOR EUIPV E \T \OYES SELF - CONTAINED GRAVITY- OPERATED EMERGENCY EYE WASH. UNIT SHALL BE A HAWS, MODEL 7500 EYE WASH WITH BACTERIOSTATIC ADDITIVE, OR EQUAL. INSTALL AS PER CODE AND MANUFACTURERS RECOMENDATIONS. CONDENSATE PUMP WITH RECEIVER, HARTELL MODEL HAR-KL-151UL, RATED AT 30 GPH AT 14' HD. CONNECT DRAINS FROM BOTH HP -1 AND HP -2 TO THE RECEIVER. PROVIDE AN 18 GA. STEEL COVER, ATTACHED TO THE FLOOR WITH 3/8" HINGES, TO ALLOW SERVICE ACCESS. CONDENSATE PUMP WITH RECEIVER, HARTELL MODEL HAR- KT- 151UL, RATED AT 30 GPH AT 14' HD. CONNECT CONDENSATE FROM AHU -1 TO THE RECEIVER. MOUNT PUMP FROM WALL WHERE SHOWN. -rt MAR 272,01I [ID CE\ERAL \CTES FOR INFORMATION ON MECHANICAL EQUIPMENT, SEE SCHEDULES ON DRAWING 11.14N-1M500. 2. CAUTION! BUILDING FLOOR SLABS ARE PRE - TENSIONED. X -RAY ALL LOCATIONS PRIOR TO DRILLING, PENETRATING OR ANCHORING TO FLOOR SLABS. 3. PRE - FILTER SECTION SHALL CONSIST OF (4) 24" X 24" X 1" FARR 30/30 FILTERS, OR EQUAL, MOUNTED IN A V FRAME IN AHU -1'S RETURN DUCT. 4. 16 X 16 SUPPLY REGISTERS ARE TO BE INITIALLY SET TO PROVIDE 1000 CFM ON EACH OF (3) REG. S.W. OF COLUMN LINE 20, AND 500 CFM ON EACH OF (3) REG. N.E. OF COLUMN LINE 20. INSTALLATION HAS BEEN SIZED FOR ADDITIONAL LOADS IN THE FUTURE. 13> 13> CO\STRCTlO\ \OYES INSTALL NEW FAN COIL AHU -1B AT LOCATION OCCUPPIED BY REMOVED UNIT AHU -1A. REWORK EQUIPMENT MOUNTS AS NEEDED. CONNECT TO CONDENSATE DRAIN PIPING INSTALL NEW CONDENSOR UNIT FOR AHU-1B AT LOCATION OCCUPPIED BY REMOVED UNIT AHU -1A. REWORK EQUIPMENT MOUNTS AS NEEDED. INSTALL NEW TYPE ACR COPPER TUBING CONNECTING INDOOR AND OUTDOOR UNITS FOR AHU-1B. REROUTE USING PREVIOUS TUBING ROUTING. NEW CLEAN TUBING IS REQUIRED FOR SYNTHETIC LUBRICANT IN NEW AHU, ALL JOINTS TO BE BRAZED WITH NITTROGEN GAS PURGE APPLIED TO SYSTEM. RECONNECT FAN COIL TO EXISTING DUCTWORK. REINSTALL FIRE SPRINKLERS AND PIPING MOVED TO PROVIDE WORKING CLEARANCE t:::::» MAINTENANCE HVAC TO INSTALL NEW CONTROL AND INTERFACE TO UNIT. M C(1 IRICTAI 1 AIr1AI r1 rrTRlr fAAADrD AACT(\D (lM CVICTIMI' (\CA fAAADrD MAINTENANCE HVAC TO CHARGE SYSTEM WITH NEW R410 REFRIGERANT AND START UP UNIT PER MANUFACTURERS INSTRUCTIONS rt,REWORK EXISTING DISCHARGE AND RETURN DUCTWORK TO SHORTEN OVERALL LENGTH TO PROVIDE SPACE FOR CLCCTRIC IICATCR STAGE AND ECONOMIZER ON AIR HANDLER ® ELECTRIC REHEAT STACE SUPPLIED BY CARRIER AS SEPERATE PIECE OF .. AMfl Rrw(1Rv FVICTIM nllrTwnRv eC Alrrnrn MOUNT ECONOMIZER STAGE PROVIDED SEPERATELY BY CARRIER AS SHOWN ON L::::» RETURN AIR STAGE OF FAN COIL. LOCATE OUTSIDE AIR OPENING ON ECONOMIZER ON BOTTOM OF DUCT AND INSTALL 4" FILTER FRAME Bl> SEE SHEET M568 FOR ADDITONAL DETAIL FOR ASSEMBLING NEW CARRIER FAN COIL AND INSTALLING AT LOCATION. MOUNT ENTHALPHY SENSOR ON EXTERIOR WALL AND CONNECT TO ECONOMIZER REVISE LOCATION OF NEW CARRIER FAN COIL TO LOCATION SHOWN TO PROVIDE CLEARANCE FROM CONCRETE CAP AT TOP OF COLUMN. POSITION UNIT TO PROVIDE 12" SPACE FROM SIDE OF UNIT TO CONCRETE. DELETE ELECTRIC REHEAT STAGE AND ADD TWO NEW SECTIONS IN EXISTING DUCTWORK AT LOCATIONS SHOWN. INSTALL NEW EXPANSION ANCHORS AFTER LOCATING TENSIONING CABLE IN SLAB WITH GROUND PENTRATING RADAR CONTRACTOR REVIEWED FOR CODECOMPLIANCE APPPAVED AUG 26 2010 City of Tukwila BUILDING DIVISION ISSUE FOR PERMIT 5285 -10 1 9266464 08/0512010 1 1- 14 -M2A 11- 14 -M334 11- 14 -M335 11 -14 -M568 REFERE\CE IRAWI\CS HVAC EQUIPMENT SCHEDULES HVAC DETAILS UPS ELECTRONICS ROOM HVAC DETAILS UPS ELECTRONICS ROOM UPS INSTALLATION - HVAC SECTIONS AND DETAIL M528� 0- RECEIVF r AUG 09 2[110 PERMIT CENTS. 16 11 KEY PLAN db b SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A AS -BUILT 570590 -001 vVILSON &ASS B REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS WDH 09/30/93 09.28.09 QBOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN ERG EISI CHECKED DATE 01/14/93 SUBTITLE UPS INSTALLATION - HVAC CURRENT REVISION 9266456 SYMBOL DATE 09.28.09 APPROVED BY DEPT. DATE ENGINEER MAI /EISI CHECKED 01/14/93 APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEM MECHANICAL MASTER BUILDING 11 -014 COL. G- H/20 -21 DUWAMISH, WA SHEET M528 JOB NO. 9266456 COMP NO. DWG NO. 11- 014 -M528 0 0 0 o to .o 0 N rn co cn a trz N tC N 9 aA .04 0 f 8 th cri 0 E DISCONNECT WIRI\ COVER PLATE J SCALE: NONE HEATER CONTROL BOX TERMINAL BLOCK TB1 FIELD POWER SUPPLY 3 PH ONLY EQUIP GND FIELD POWER WIRING 411 a _ 4 1 , C.1 CARRIER FA\ COIL G DAGRAv FRv I\ -TA 1 L M528JM 1 68 CIRCUIT BREAKER (5 HP AND LARGER) IFC UNIT WIRING IFM vCTOR A\ STALLATIO\ SCALE: NONE HEATER v1A\ AL M5701 M568 THERMOSTAT w1/o /e Y1 MISC2 CK1 CKGND O R 0 C ECONOMIZER CONTROL POWER TRANSFORMER USE FOR TERMINATION ONLY NO CONNECTION AT FAN UNIT COMPRESSOR RELAY 0 ® I e FAN RELAY 24 VAC RETURN 24 VAC COMMON 0 WHT RED BLK CONDENSATE DRAIN OVERFLOW SW /RELAY Y1 Y2 W1 W2 O R C O ® 0 G X I 1 BLK 24 Vac II ER RELAY WHT CONDENSATE DRAIN OVERFLOW RELAY ® 1 .� 2 © 0 0 0 v 0 0 0 0 COMPRESSOR RELAY 24 VAC RETURN 24 VAC COMMON FAN RELAY FAN UNIT CONDENSER CONTROL POWER TRANSFORMER O ER RELAY 0 0 IFC (INSTALLED, SHOWN FOR CLARITY ONLY) BRN CONDENSING UNIT Y1 Y2 W1 W2 RC) 0 0 0 Val © En WI YEL 4■, TR CSO SR COMPRESSOR RELAY 0 BLU X LLSV (NOT SUPPLIED) A2 RED RED O TR1 5 2 4 T1 P1 RiE ENTHALPY SENSOR ECONOMIZER ACTUATOR SAT SENSOR O O LPS HPS 0 O COMPRESSOR SAFETY SWITCHES 0 WINTER START ACCESSORY O BLK 23 24 Vac 0 RED v © CARRIER PROVIDED WIRE HARNESS O FIELD INSTALLED WIRING O CARRIER INSTALLED WIRING WIRE NUMBER USED ON DETAIL 3 SHEET M568 EMI 0 CARRIER AIR C\TO\ER SI WIRI \G DIAGRAv vPLIFIED VI SCALE: NONE C 0 0 BRN COMFORT ALERT DIAG MODULE BRN 0 COMPRESSOR CONTACTOR M570M568 BLK 1) CE\ERAL \OTES 1) COVER PLATE DETAIL WAS RELOCATED FROM EXISTING SHEET M528 2) AHU -1B ACCESSORY STAGES. ELECRIC REHEAT: TUTCO CAELHEAT017A00. ECONOMIZER CARRIER CAECOMZROO2A00 DEVICE LOCATED AT CARRIER FAN COIL DEVICE LOCATED AT CARRIER FAN COIL ECONOMIZER DEVICE LOCATED AT CARRIER CONDENSER CO \STR CTIO\ �orEs CONNECT CARRIER AIR CONDITION COMPONENTS AS SHOWN IN DETAIL 3. ALSO DAIGRAMS ON SHEET M570 FIELD RUN WIRING © FIELD INSTALLED CARRIER PROVIDED WIRING HARNESS !m! ffE MAR 2 7 201 11- 14 -M2A 11- 14 -M334 11- 14 -M335 11 -14 -M528 11- 14 -M570 REFERE \CE DRAM \GS HVAC EQUIPMENT SCHEDULES HVAC DETAILS UPS ELECTRONICS ROOM HVAC DETAILS UPS ELECTRONICS ROOM UPS INSTALLATION - HVAC UPS INSTALLATION - HVAC SECTIONS AND DETAILS ISSUE FOR PERMIT 5285 - 1019266464 08105/2010 A kpq 4/3:01411/rAA,r$ QUiRt44 D ECEIVEr AUG 09 2010 PERMIT CENTE, SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS 02.15.10 Z)LAsousrirAv”°31 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN LM THOMAS DATE 02.09.10 CHECKED SUBTITLE UPS INSTALLATION - HVAC SECTIONS AND DETAILS CURRENT REVISION 9266456 SYMBOL DATE 02.15.10 APPROVED BY DEPT. DATE ENGINEER LM THOMAS CHECKED 02.09.10 APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEM MECHANICAL MASTER BUILDING 11 -014 COL. G— H/20 -21 DUWAMISH, WA SHEET M568 JOB NO. 9266456 COMP NO. DWG NO. 11- 014 —M568 (U 71 -5" 1 CU Z-4 3i• 6' -104' AHU -1 B RETURN ISLET STAGE SCALE 1/4 " =1'0" AIR 36' 7' -0 6' -2 rTh M528 M569 MOUNT FILTER FRAME ON OSA INLET AHU -1E ECO \OVIZER STACE SECTIO\ - I\ LET STAGE SCALE: 1/4 "=1'0" 124 18i izt N 54 AHU -1B HEATER STAGE SECTO\ 0„TLET STAGE SCALE: 1 /4. -1.0" EXISTING ELBOW ECONOMIZER STAGE 1 M5281 M569 M528M569 CU ECC AH ECONOMIZER INLET \OvIZER N -1 B I \LET SCALE: 1/4 " =1'0" FAN COIL INLET rNO OU\TED 0\ - E \D VIEW M528 569 EXISTING ELBOW 71 -51 18 188 158 526 AHU -1B SUPPLY AIR OUTLET STAGE SCALE: 1/4 " =1'0" FLOOR PAN AT TOP OF COLUMN, 9" BELOW FLOOR 1 1 1_ EXISTING ELBOW 1 cab 1 1 • M528yM569 20' -8i 48 24 5 CERTIFIED DIMENSION - ACCESSORIES FOR 40RUA14, 16 OVERHEAD SUSPENSION ACCESSORY CARRIER 40 RJA OVEPHEAI FROv CERTIFIES DI v E SUSPE \SIO\ \510\ qT P r-a- P SCALE: NONE 10' -10 1 STRUCTURAL COLUMN 49 21 50 25 NEW TRANSITION 64 EXISTING TRANSITION TO CLEAR SPRINKLER Ow- CARRIER PROVIDED MOUNTING BRACKETS FOR i,' THREADED ROD 4 PLACES NEW TRANSITION 1 APPROXIMATE LOCATIONS EXISTING INSERTS FOR ORIGINAL AIR HANDLER 6 PLACES ECO \OvIZER I \LET. - PLA\ SCALE: 1/4 " =1'0" CARRIER 40RUA FAN COIL v OU \TES 0\ AHU -1B VIEW WITH ELBOW 10' -10" (5 M528 M569 4' -8j" 1 %, -- �i ■, � / 524 N ECONOMIZER STAGE a 48 EXISTING ELBOW 12 53 12 HEATER STAGE - PROPOSED DELETION ECO \OvIZER MOU I \LET - ELEVATIO SCALE: 1/4 " =1'0" 1 N \TES 0\ AHU -1 B WITH ELBOW re M528 M569 M528 M568 1) GENERAL NOTES AHU -18 ACCESSORY STAGES. ELECRIC REHEAT: TUTCO CAELHEAT017A00. ECONOMIZER CARRIER CAECOMZROO2A00 - LISTED WEIGHT 340 LBS 2) AHU -1B OUTDOOR UNIT 38AUZ - OPERATING WT 431 LBS. FAN COIL 40RUA - OPERATING WT 713 LBS 1 EXISTING MOUNTING POINTS FOR SPRING ISOLATORS ATTACHING ORIGIANL AHU -1A TO CONCRETE SLAB NEW MOUNTING POINTS FOR SPRING ISOLATORS ATTACHING REPALCEMENT FAN COIL TO CONCRETE SLAB CO\ sTR cTio\ NOTES MOUNT REPLACEMENT FAN COIL AHU -1B IN LOCATION SHOWN. POSITION FAN NEAR SIDE OF FAN COIL AT LEAST 12" FROM NEAREST POINT OF FLOOR PAN AT INTERFACE BETWEEN FIREPROOFED GARAGE CEILING AND CONCRETE COLUMN. SEE STRUCTURAL DRAWINGS FOR DETAILS ON ATTACHEMENT TO TENSTIONED FLOOR SLAB. HAVE PROPOSED INSTALLATION LOCTIONS SURVEYED WITH RADAR BY CONTRACTOR 2) AFTER INSTALLATION LOCATION OF NEW AHU -1B HAS BEEN FINALIZED, RELOCATE EXISTING SUPPLY AND RETURN DUCTWORK TO LINE UP WITH CENTERLINE OF INSTALLED UNIT. REINSTALL DUCTWORK SUPPORTS INTO CONCRETE AT LCOATIONS TO MATCH SUPPORTS ON DUCTWORK. HAVE CABLE AND REBAR LOCATIONS MARKED PRIOR TO INSTALLING ANCHORS PER STRUCTURAL DETAILS MAR'27.`201I 11- 14 -M2A 11- 14 -M334 11- 14 -M335 11 -14 -M528 11 -14 -M568 P'Uo� it2 REFERE CE DRAM \GS HVAC EQUIPMENT SCHEDULES HVAC DETAILS UPS ELECTRONICS ROOM HVAC DETAILS UPS ELECTRONICS ROOM UPS INSTALLATION - HVAC UPS INSTALLATION - HVAC SECTIONS AND DETAILS ISSUE FOR PERMIT 5285 -10 / 9266464 08/05/2010 REVIEWED FOR CODE COMPLIANCE APPROVED AUb 2 2010 City of Tukwila BUILDING DIVIRIf 1N kit ECEIVEP AUG 09 2010 PERMIT CENTEF REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS 03.15.10 Q1 BOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED DATE 03.15.10 SUBTITLE UPS INSTALLATION - HVAC SECTIONS AND DETAILS CURRENT REVISION 9266456 SYMBOL DATE 03.15.10 03.15.10 APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEM MECHANICAL MASTER BUILDING 11 -014 COL. G- H/20 -21 DUWAMISH, WA SHEET M569 JOB NO. DWG NO. 9266456 11- 014 -M569 COMP NO. J 1 1 COM co L 1 0 ECONOMIZER STAGE 0 EXISTING ELBOW N N 00 ON ON co N n 0[ �. 40RUA CARRIER FAN COIL .. [ ECO \OvIZER I \LET. - PLA\ SCALE: 1/4 " =1'0" CARRIER 40RUA FAN COIL v OU \TES 0\ AHU -1B VIEW WITH ELBOW 10' -10" (5 M528 M569 4' -8j" 1 %, -- �i ■, � / 524 N ECONOMIZER STAGE a 48 EXISTING ELBOW 12 53 12 HEATER STAGE - PROPOSED DELETION ECO \OvIZER MOU I \LET - ELEVATIO SCALE: 1/4 " =1'0" 1 N \TES 0\ AHU -1 B WITH ELBOW re M528 M569 M528 M568 1) GENERAL NOTES AHU -18 ACCESSORY STAGES. ELECRIC REHEAT: TUTCO CAELHEAT017A00. ECONOMIZER CARRIER CAECOMZROO2A00 - LISTED WEIGHT 340 LBS 2) AHU -1B OUTDOOR UNIT 38AUZ - OPERATING WT 431 LBS. FAN COIL 40RUA - OPERATING WT 713 LBS 1 EXISTING MOUNTING POINTS FOR SPRING ISOLATORS ATTACHING ORIGIANL AHU -1A TO CONCRETE SLAB NEW MOUNTING POINTS FOR SPRING ISOLATORS ATTACHING REPALCEMENT FAN COIL TO CONCRETE SLAB CO\ sTR cTio\ NOTES MOUNT REPLACEMENT FAN COIL AHU -1B IN LOCATION SHOWN. POSITION FAN NEAR SIDE OF FAN COIL AT LEAST 12" FROM NEAREST POINT OF FLOOR PAN AT INTERFACE BETWEEN FIREPROOFED GARAGE CEILING AND CONCRETE COLUMN. SEE STRUCTURAL DRAWINGS FOR DETAILS ON ATTACHEMENT TO TENSTIONED FLOOR SLAB. HAVE PROPOSED INSTALLATION LOCTIONS SURVEYED WITH RADAR BY CONTRACTOR 2) AFTER INSTALLATION LOCATION OF NEW AHU -1B HAS BEEN FINALIZED, RELOCATE EXISTING SUPPLY AND RETURN DUCTWORK TO LINE UP WITH CENTERLINE OF INSTALLED UNIT. REINSTALL DUCTWORK SUPPORTS INTO CONCRETE AT LCOATIONS TO MATCH SUPPORTS ON DUCTWORK. HAVE CABLE AND REBAR LOCATIONS MARKED PRIOR TO INSTALLING ANCHORS PER STRUCTURAL DETAILS MAR'27.`201I 11- 14 -M2A 11- 14 -M334 11- 14 -M335 11 -14 -M528 11 -14 -M568 P'Uo� it2 REFERE CE DRAM \GS HVAC EQUIPMENT SCHEDULES HVAC DETAILS UPS ELECTRONICS ROOM HVAC DETAILS UPS ELECTRONICS ROOM UPS INSTALLATION - HVAC UPS INSTALLATION - HVAC SECTIONS AND DETAILS ISSUE FOR PERMIT 5285 -10 / 9266464 08/05/2010 REVIEWED FOR CODE COMPLIANCE APPROVED AUb 2 2010 City of Tukwila BUILDING DIVIRIf 1N kit ECEIVEP AUG 09 2010 PERMIT CENTEF REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS 03.15.10 Q1 BOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED DATE 03.15.10 SUBTITLE UPS INSTALLATION - HVAC SECTIONS AND DETAILS CURRENT REVISION 9266456 SYMBOL DATE 03.15.10 03.15.10 APPROVED APPROVED TITLE REPLACE CRITICAL COOLING SYSTEM MECHANICAL MASTER BUILDING 11 -014 COL. G- H/20 -21 DUWAMISH, WA SHEET M569 JOB NO. DWG NO. 9266456 11- 014 -M569 COMP NO. Y2 = SECOND STAGE OF COOLING W3 = THIRD STAGE OF HEAT ECON = OUTPUT POINT FOR ECONOMIZER W3 PROG HUM DEHUM Y2 MISC1 ONLY 00 CICI 00 00 00 CICI 00 ga 00 00 Ea 00 00 JUMPER JUMPER JUMPER MISC1 MISC2 MISC3 W2 RS2 2ND STAGE HEAT CIRCUIT REMOTE SENSOR 12 (OSA) MSC? RS+ REMOTE SENSOR +5 VOLTS REMOTE SENSOR(S) - ROOM REMOTE SENSOR CRNDS RS1 7 W3 PROG HUM DEHUM ECON FOR MISC2 AND MISC3 ONLY CARRIER MODEL 33CS450 -01 THERMOSTAT J1 J2 J3 1ST STAGE HEAT CIRCUIT COMPRESSOR RELAY FAN RELAY DRY CONTACT DRY CONTACT 24 VAC COMMON 24 VAC RETURN 1 ELECT GAS HP GAS W1 - Y1 - G ISC2 CK1 B 0 TO FAN RED COIL TB1 CARRIER THERV OSTAT WIRI\ FRGV \STALLATO\ v A\ G DIAGRAN UAL SCALE: NONE 2 WIRES 2 WIRES 2 WIRES 2 WIRES LINE 24 V TRANSFORMER J D X ENTHALPY SENSOR MIXED AIR SENSOR E X B X 1 WIRE ECONOMIZER 4 WIRES TO FAN COIL TB1 TO FAN .- COIL TB1 M568 M570 C AIR HANDLER F X ECONOMIZER RELAY ROOM THERMOSTAT X 4 WIRES WIRING NUMBERS GENERATED ON M568 DETAIL 3 G X CONDENSATE LEVEL SWITCH CARRIER AIR HA\:LER WIRI \G SCHEvATIC WITH WIRE COU \T M568 M570 H X CONDENSER UNIT TRANSFORMER SUPPLIED WITH ECONOMIZER ACCESSORY. PRIMARY HAS 200, 230, AND 460 VOLT TAPS. CONNECT OT LINE VOLTAGE SUPPLY USING CORRECT TAP 4 WIRES 5 WIRES 2 WIRES SCALE: NONE J 24 V TRANSFORMER 24 VAC FROM CONDENSING UNIT R r L1 ECONOMIZER RELAY CONTACT r L. [BLACK I ® I L2 38AU CONDENSER TERMINAL BLOCK TB1 24 VAC RETURN J. 24 VAC COMMON ■24 VAC COMMON COMPRESSOR RELAY TO THERMOSTAT 1ST STAGE _SEAT CIRCUIT _Ai. 24 VAC RETURN FAN RELAY 40RU FAN COIL CONTROL BOX TERMINAL BLOCK TB1 1ST STAGE HEAT CIRCUIT R Y1 Y2 W1 W2 x A2 TRANSFORMER ACTUATOR POWER COMPRESSOR RELAY BLUE 0 1 L WHITE ENTHALPY SENSOR r © BLACK ® ® ® WEE_ GREEN ® I ORANGE RESISTOR, SEE NOTE 2 RED ® ECONOMIZER ECONOMIZER RELAY CLOSES OSA DAMPER j- - —j WHEN FAN IS OFF 1 F. L_J 1 L a3 i® 4 NC YELLOW C>0.1 BROWN ® L AIR HANDLER TB1 r L FAN RELAY r24 VAC RETURN 7 R Y1 Y2 W1 W2 G x A2 C1 4 C2 2 1 NC CONDENSER OVERFLOW RELAY El WIRE NUT TYPICAL THIS SYMBOL 1K ACTUATOR 1S oo 1 S 1 D MINIMUM POSITION ADJUSTMENT 11 0 24 VAC MIXED AIR SENSOR MINIMUM POSITION 2ND STAGE COOLING BLUE ® J ECONOMIZER 1 1 ® CARRIER PROVIDED WIRE HARNESS ® 1ST STAGE COOLING AT FAN COIL ® CARRIER PROVIDED WIRE HARNESS ® 1ST STAGE COOLING AT TSTAT © JUMPER AT HONEYWELL MODULE ® CARRIER PROVIDED WIRE HARNESS ® CONNECTION TO 28 VAC POWER NOTE: THIS DIAGRAM ONLY SHOWS THE ADDITIONAL WIRING REQUIRED TO CONTROL THE ECONOMIZER STAGE. POINTS RELATED TO THE FAN COIL, CONDENSER AND HEATER ARE SHOWN BELOW CARRER ECO FROv I \S \ON IZER wiRi\ TALLATIO\ N A\ G INACRAV UAL 3 SCALE: NONE INDOOR FAN CONTACTOR WHT ■ I L _ I WHT W1 W2 c J 1. L CONDENSER OVERFLOW 1 SWITCH -r L FIELD INSTALLED WIRING, TYPICAL .l. L 1ST STAGE HEAT CIRCUIT I W1 FAN RELAY Y1 CK1 HEATER CONTROL BOX TERMINAL BLOCK TB2 I _J 24 VAC COMMON j CONDENSER I OVERFLOW RELAY GR 24 VAC RETURN G C 1�ISC N CONNECT TO 24 VAC AT CONDENSING UNIT THERMOSTAT [ --- L LIQUID LINE SOLENOID VALVE 38AU CONDENSER TERMINAL BLOCK TB1 I "1 [Y1 Y2 W1 W2 G x . A2 FACTORY INSTALLED WIRING, TYPICAL 24 VAC COMMON COMPRESSOR RELAY BLU 1 LPS RED YEL HPS M568 M570 CONDENSER POWER TRANSFORMER 24 VAC RED COMFORT ALERT DIAGNOSTIC MODULE 24 VAC BLK L 2 BRN BRN BRN 24 VAC RETURN CARRIER FA\ COIL W RI \G FRCv I \STALLATIG\ I WINTER START ACCESSORY BLK SCALE: NONE VIO DIAGRAv vA \UAL REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REPLACE CRITICAL COOLING SYSTEM 9266456 LM THOMAS 05.06.10 elfirAPAEZAW ® M568 M570 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED BRN COMPRESSOR CONTACTOR 1) GE \ERAL \OTES COVER PLATE DETAIL WAS RELOCATED FROM EXISTING SHEET M528 2) AHU -1 B ACCESSORY STAGES. ELECRIC REHEAT: TUTCO CAELHEAT017A00. ECONOMIZER CARRIER CAECOMZROO2A00 13%- I>• MAR 2 7 201 i CO\STR CTIO\ \OTES FIELD RUN WIRING FIELD INSTALLED COMPONENT USE DIAGRAM ON DETAIL 3 ON SHEET M568 FOR ELECTRICAL INSTALLATION OF NEW FAN COIL. DETAILS 3 AND 4 THIS SHEET ARE REFERENCE ONLY. 11- 14 -M2A 11- 14 -M334 11- 14 -M335 11 -14 -M528 11 -14 -M568 11- 14 -M569 X110 -112 ISSUE FOR PERMIT 5285 -10 / 9266464 08/05/2010 REFERE \CE DRAW\CS HVAC EQUIPMENT SCHEDULES HVAC DETAILS UPS ELECTRONICS ROOM HVAC DETAILS UPS ELECTRONICS ROOM UPS INSTALLATION - HVAC UPS INSTALLATION - HVAC CONTROL DIAGRAMS UPS INSTALLATION - SECTIONS AND DETAILS asFAq 9� 90k �0,9 '44 W 9 "I ECEI�� Fp AUG 0 9 2010 PERMIT CENTE- APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS DATE SUBTITLE 05.06.10 UPS INSTALLATION - HVAC SECTIONS AND DETAILS CURRENT REVISION 9266456 SYMBOL DATE 05.06.10 TITLE 05.06.10 CHECKED APPROVED APPROVED REPLACE CRITICAL COOLING SYSTEM BUILDING 11 -014 MECHANICAL MASTER COL. G- H/20 -21 SHEET M570 JOB NO. DUWAMISH, WA DWG NG. 9266456 11- 014 -M570 no-A- COMP NO.