Loading...
HomeMy WebLinkAboutPermit M10-115 - ARMED FORCES RECRUITING CENTERARMED FORCES RECRUITING CENTER 16600 SOUTHCENTER PY M10 -115 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 2623049137 Address: 16600 SOUTHCENTER PY TUKW Project Name: ARMED FORCES RECRUITING CENTER Permit Number: M10 -115 Issue Date: 09/08/2010 Permit Expires On: 03/07/2011 Owner: Name: PARKWAY SQUARE Address: C/0 ROSEN PROPERTIES , PO BOX 5003 98009 Contact Person: Name: JOFFRE SECHIER Address: 6802 S 220 ST , KENT WA 98032 Email: JOFFRIE @COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425 - 251 -9840 Phone: 425 - 251 -9840 Expiration Date: 06/01/2012 DESCRIPTION OF WORK: REWORK EXISTING AIR DISTRIBUTION FROM 4 EXISTING ROOFTOP UNITS. INSTALL (1) 5 TON UNIT WITH AIR DISTRIBUTION. INSTALL (3) EXHAUST FANS. Value of Mechanical: $19,250.00 Fees Collected: $428.56 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009 Permit Center Authorized Signature: Date: 4 ( I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o • erformance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: 9 A/co This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10-115 Printed: 09 -08 -2010 • City of Tukwila . Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 �2 Phone: 206 -431 -3670 -.- Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049137 Address: Suite No: Tenant: 16600 SOUTHCENTER PY TUKW PERMIT CONDITIONS ARMED FORCES RECRUITING CENTER Permit Number: Status: Applied Date: Issue Date: M10 -115 ISSUED 08/20/2010 09/08/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Readily accessible access to roof mounted equipment is required. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10-115 Printed: 09 -08 -2010 • ► w4� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or performance of work. Signature: Print Name: Date: 9h7,6 doc: Cond -10/06 M10 -115 Printed: 09 -08 -2010 08- 20 -'10 09 :49 FROM- publicworks /dcd CITY OF TUKWIiLA • Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100. Tukwila, WA 98188 - htte://www.ci.tukwila.wa.us 2064313665 T -773 P002/005 F -936 MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review, Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.a10Q3OL1 913 Site Address: D 1 Tenant Name; ., Property Owners Name: Mailing Address: Floor: tll Yes ❑ ..No Suite Number. New Tenant: City cONTAc'y 1E% s` V6q. dove cbf'itaq w1)0 yr pe�+l IQ,I'19�i Name: Mailing Address:1,lO80D Sh Qao E -Mail Address: Sums Zip • 1 • D7 Telephone: titiAT City State) Zip Fax Number: q. —DSO — 9 il- d ..:. CRANICAL•:CONTRACTORINFORM1 ' Company Name: Mailing Address: Contact Person: E -Mail Address �Q o 80 s 1 SO • Contractor Registration Number: COW A'OW t . OIL. L641 City State Q Zip Day Telephone: Fax Number: —� �— 487 Expiration Date: 0l / o� MITIC't OE: RRA4� 411p 10 We`t. k4iIitRed fif:Aixhitect nj Reeora Company Name: , Mailing Address: Contact Person: City Day Telephone: E -Mail Address: _ Fax Number: Stola Zip ENGI TEER:QP!... �ORfl ,AQ pia 9.ma t.be wet'stampcd _by Zngineer of Record, Company Name: Mailing Address: - City Contact Person: ` ( Day Telephone: E -Mail Address: Fax Number: df Stare Zip H:tApplirationsWorn:•Applcraiont on Line k2009 ApplicatiomM -2009 - Machanicd Palmil Appl.Wion.doc Ravixa& 1 -2009 bh Pagc 1 of 2 08- 20 -'10 09:50 FROM- publicworks /dcd 2064313665 T -773 P003/005 F -936 Valuation of Project (contractor's bid price): $ Scope o Work (pl- : se provide detain nf Iation): Scl 1 t 1'Mk 1 .rl' U --a;v42i,k1 us-Rewxs — _ ibc'%-) i Ga►v S L' t,., Use: Residential: New Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: Upit:Type :. ' 'Qty , •:Unir le;.: Qty.. ":Unit.TYR ... . '. .;..:ettY •.: $oiler /Coiiipl'essdr; ...'.Q.iy` Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser D-tp 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 3 Thermostat 15-30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30.50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP/1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System . Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM I_ Incinerator — Comm/Ind Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING s r` OR AUTHORIZED AGENT: Signature: ZALLPrint Name: Mailing Address: Date: $%o`LO Day Telephone: '1,01 '. 1— I Ci State Zip Date Application Accepted: Date Application Expires: Staff Initials: MAApplicationsVaarm. Appliutiona On 1;nc',2009 Appliaotions11.2009 • Mechanical Pon>til Apphcanon.doo Raviead: 1 -2009 b' Page 2 of 2 • • �wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049137 Permit Number: M10 -115 Address: 16600 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 08/20/2010 Applicant: ARMED FORCES RECRUITING CENTER Issue Date: Receipt No.: R10 -01641 Initials: WER User ID: 1655 Payment Amount: $428.56 Payment Date: 08/20/2010 02:08 PM Balance: $0.00 Payee: JOFFRIE SECHIER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 610270 ACCOUNT ITEM LIST: Description 428.56 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 342.85 000.345.830 85.71 Total: $428.56 doc: Receiot -06 Printed: 08 -20 -2010 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 m/o — /icS Project: _ eq�meZ 1.-QmPeES Type of Inspection: F ,t/'4• / ./ Address: t 1 .5 '/r!4e.s.41 ,-' d p Date Called: r Special Instructions: . 0',/ `6/GO -0l `'Date Wanted: a.m. Requester: Phone No: t-34 3 —y?35. ElApproved perapplicable codes. ElCorrections required prior to approval: `COMMENTS: ?4, • . ./ ?f,544,110 J- ,}�`p•r :r/ i / -Gtvee AJ Kt/ / -,il¢ T'-14:-; Inspetor ;ritAitokor- INSPECTION FEE REQUIRED. Pr r to aid at 6 @00 Southcenter Blvd., Suite 100: Date: next inspection. fee must be" Call to schedule reinspection. • -cW 7_, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-R70 Permit Inspection Request Line (206) 431 -2451 Project: r - Type of Inspection: _ RCSi.#G 1A4 Address: rr� Date jlle �At , _ a A. �...4 Special Instructions: o4 35 f'C �� tr •� t,„+t; il/N Date Wanted: gym. ✓ .- p.m. Requester: Phone No: 71) C, - 315' 4237 Approved per applicable codes.. COMMENTS: Corrections required prior. to approval. . /` 2 �(4-4 A Inspeq or: Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. l INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188• (206) 431-360 Permit Inspection Request Line (206) 431 -2451 Project: • • , /90'19./ PaRee s Type of Ihspection - ReD14: t-.,n,/ Address: /461,040 .,."d 10 , AI Date Called: Special Instructions: - - . Date Wanted: 9 /�' //C� (m., . Requester: Phone No: © Approved per applicable codes. Corrections required prior t� approval. COMMENTS: p ,4 f 'Ca Zv'S2/c,4- n- S • SPECTION FEE RE4 IRED. Prior t next inspection. fee must be at 6300 Southcenter B vd.. Suite 10 . Call to schedule reinspection. OF TUKWILA 1 444 Andover P "%k East. Tukwila, Wa. 981 DEPARTMENT Project: , r ; > � P, s Type of Inspection • ' Monitor: ?lr'L v ,.__ Suite / t. o Suite # • • ; {:` > , ;! ,; Contact Person,: �^ {� aq ^ S! t ` i 1 t� tir 8 t � j Special Instructions: Phone No: fs Approved per applicable codes. Corrections required prior to approval. CI)MMENTS: Sprinklers: t Fire Alarm: s Hood v & Duct: Monitor: ?lr'L Pre-Fire. Permits: `� Occupancy Type: . {` ,,fir f✓ kin 1 "�.`•�J., { (51,Z „. A 'k `VI rf [.� t .. '""7/ r f - iF FIB %, p II ik ,' /. ; I . ■ (. tG 9 � i } f..: Needs Shift Inspection: °; Sprinklers: t Fire Alarm: s Hood v & Duct: Monitor: ?lr'L Pre-Fire. Permits: `� Occupancy Type: . Inspector: c�. z. , Dam: , , 1 w ;. Hrs.: $80.00 R�EINSPECTION FEE REQUIRE . You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 444 Andover Park East Tukwila Wa. 98188 206- 575 -4407 Project: ? eli 1,i f GECe Type of Inspection: -- / %� :1 l t��,"`�,, Monitor. Add BOO Sum # • � F Con Person: C .i"s I x,41) m ... cM t i`{:, ��.... Special Instructions: Phone Noy ,110(,_ -c.fr _ .. a ,, i Approved per applicable c La corrections required prior to approval. OXIMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor. Pre -Fire: permits: Occupancy Type : // , , fr (C,,, -," f ,e, e u' � 1q4 i �. S? ^,.3 i C ^ • 'a �r L ? b r 1`,s "c-,i. °' ta, . i t `, t£ Y 1 q'Gr^.e" .A ! r,.�� 'L` r. �,6, tt1 — e11i ,. f .S b1 L -ia f ✓J ,.' ', ■) 1 'f �r '1Ga. 4, ' ="i" - -yJ ? c- net/VP ED) z 4r;trt %P 1 . erg r s: ,' o `'' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor. Pre -Fire: permits: Occupancy Type 1 Inspector: H • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. Project: Armed Forces Recruit Prepared By: Unit Report For 5T Gas EIe -13 Seer 06/24/2010 03:40PM Unit Parameters Unit Model: 48TCDA06A2A5 -0A0A0 Unit Size: 06 (5 Tons) Volts- Phase - Hertz: 208 -3-60 Heating Type: Gas Duct Cfg: Vertical Supply / Vertical Return Heating Capacity: Low Heat Unit Configuration Medium Static Option AI /Cu - AI /Cu Electro - mechanical controls Standard Packaging Warranty Information First Year - Parts Only (Standard) No optional warranties were selected. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Dimensions (ft. in.) & Weight (Ib.) '"** Unit Length: 6' 2.375" Unit Width. 3' 8" Unit Height. 2' 9375" Base Unit Weight: 619 Ib Economizer Weight 65 Ib Curb Weight 94 Ib "• Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. FILE COPY Permit No.. Ordering Information Part Number Description Quantity 48TCDA06A2A5 -0A0A0 Rooftop Unit 1 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid -state controller - 0688 -0101 1 CRRFCURBb01A01 14 -inch Tall Roof Curb — 0537 -014A 1 REVIEWED FOR CODE COMPLIANCE SEP 0 8 2010 City of Tukwila BUILDING DIVISION t/1lo., • 115 RECEIVED AUG 20 2010 PERMIT CENTER Packaged Rooftop Builder 1.19x Page 1 of 7 )6/24/2010 Prepared By: Certified Drawing for 5T Gas EIe -13 Seer Project: Armed Forces Recruit 03:40PM NOTES: I. DIMENSIONS ARE IN INCHES, 50050(551003 [N 1 5 ARE IN MILLINEIERS. 2. S CENTER OF GRAVITY 3. DIRECTION OF AIR FLOW FILTER ACCESS PANEL [DISPOSABLE FILLERS) • INDOOR COIL ACCESS PANEL :I•I0111MINNIII SCALE 1'0 UNIT 4476-.01 33 3(8 18411 185/8 14721 48TC--05 33 3/8 18471 14 748 13771 /811 - -06 33 3/8 18477 14 7/8 [3771 1411 - -07 41 340 110511 14 718 13771 BACK 2.5/6 1671 TYP CURB WIDTH CONDENSER COIL 44 4 -5/8 (1181 0 UNITED 1. 0 Om w1 TECHNOLOGIES sn41s[. 4 CARRIER 4112. 1111 WP0.1 It 70[ P1070111 Of CUM 10100101110 Ca1)115 84010 02 11ARGi01 al l 0[0.110041 0010141 [0010111Im'N 01111(0 0000111. 700 0 001110 lil[ *71 5017 000100404081 [1714[ 08 181100)[ 33 348 [8481 ECONONIlER H000 (OPTIONAL) '----ELECTRICAL DISCONNECT LOCATION 6 -5/8 11681 19-112 [4941 46 3/4 LEFT 16.5/8 [4111 18. 148 14. 114 12 -111 (1591 I 13631 13121 • BASE CHART. 16 [4061 25 5/8 16321 10.1/8 [ 171 RETURN AIR E ALT. — CONDENSATE DRAIN OPENING IN 840050N 11.3/4 [4511 6-114 11571. 28 -3/8 07471 26.1/2 16131 T 25 16361 —~ 32 1/4 14141 TOP 3.3/8 12-1/8 1851 13071 .�— 18 -1/2 —+ 14701 CONTROL DO1 ACCESS PANEL INDOOR BLOWER ACCESS OOP. 30 I/O [1641 - 0.3/6 02131 74 3/8 118881 FRONT SUPPLY AIR TRIM THE BASE C ART THESE NOLES REO-D OR USE C5514P82001001. 2401. 3401. CONNECTION SIZES A 1 3/8' DIA 1351 FIELD POWER SUPPLY HOLE B 2• [501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' DIA 1511 GUNGE ACCESS PLUG 0 118' DIA 1221 FIELD CONTROL WIRING HOLE C 314' -14 NP1 CONDENSATE DRAIN F 1/2'-11 NP1 GAS CONNECTION G 2 112 ' DIA 1641 POWER SUPPLY KNOCK-OUT TRIM THE BASE C ART THESE NOLES REO-D OR USE C5514P82001001. 2401. 3401. 4001 1/2' ACC. 1/0. 122.21 — — 14211 I 1 /2' 248 716' 122.21 3/4' 1001.0031 POWER. 1 I /e' 128,4) 1 1 /4' (002.0041 POWER. 1 314' 144.41 (0031 1 /2' FTP GAS 1 1/4' 131.81 10041 3/6' FTP 605 1 5/6' 141.31 . SELECT EITHER 3/4' OR 1 1/d. FOR POWER. DEPENDING ON WIRE SIZE 42651 E STO — CONDENSATE 00042 • I 25.1/6 16381 I116.311 — — 14211 I /4 OUTSIDE AIR 31 1/4 SUPPLT 11931 4(0 * AIR RIGHT BRAONE10(C RELIEF FLOW MET 1012 4171 1 -10 -01 FO1[4[0[F 48TC 04 -07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 2.0 SCALE I:8 Packaged Rooftop Builder 1.19x Page 2 of 7 06/24/2010 Prepared By: Certified Drawing for 5T Gas EIe -13 Seer Project: Armed Forces Recruit 03:40PM UNIT STD. UNIT WEIGHT CORNER WEIGHT (Al CORNER WEIGHT 181 CORNER WEIGHT ICI CORNER 90(6HT (01 C 4 HEIGHT LBS. KG. L05. KG. LBS. KG. LBS. KG. LBS. KG. R T 2 181C - -01 403 219 111 50 125 57 131 58 116 53 39 (9911 23 (5011 16 318 11161 18IC - -05 537 244 124 56 139 63 145 66 129 59 39 (9911 23 (5841 17 (4321 1811 --06 569 258 131 59 117 67 154 10 137 62 39 (9911 23 (5011 17 111 (4301 18(1 - -07 652 286 150 60 169 16 116 00 157 71 39 (9911 23 (5011 20 118 (5111 SCALE 5:32 CORNER A TOP 6 UNITED •.0 101 TM TECHNOLOGIES S111CDDS. R CARRIER 11:11 ISIS 1D0 0 41((PD 0a' 10ETONED C(1Olqu004 (90 (OSIERS Till NOT I( O 1x •I11 DISCLOSED CO •SIO •10111 CUI C11.11SSION 1 INDIO (PS(•1. 0050?05151 01 (9(1( 11A01•GS 00 000 101 00(0 p10CC(0TIrt(001 &fl 995000UlL( 00 CORNER 8 CORNER C O . : oo BACK 000(1 20E2 011E 1-10-01 00•(•(0((5 48TC 04 -01 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 4811,4500993 6[v 2.0 Packaged Rooftop Builder 1.19x Page 3 of 7 )6/24/2010 Prepared By: Certified Drawing for 5T Gas EIe -13 Seer Project: Armed Forces Recruit 03:40PM Packaged Rooftop Builder 1.19x Page 4of7 UNITED H =m .. TECHNOLOGIES '° CARRIER m..,• ....,.....................• ...,re.O. • ,�.,.,a . ,.... 3 Y_ ROOFCURB ACCESSORY A UNIT SIZE NOTES, 1. ROOFCURB ACCESSORY UNIT 0 " -0 i/ [6.3) ) NAIL wrt04/73/03 I 11/79/7001 REV R I__ 4BMJ /TJ /TF /TM004 -007, 50MJ /TJ /TF /TM004 -007 I SODK501028 50MJ0 /TJO /1F0004 -007 ROOF CURB S CRRFCURBOOTA01 1' -Y [356] 48/50 HJ /TJ /TF /TM 004 -007 SOHJO SOTJO /UFO 004 -007 IS SHIPPED DISASSEMBLED. 2. INSULATED PANELS. GASKET 3. DIMENSIONS IN [ ) ARE IN MILLIMETERS. (SUPPLIED WITH CURB) 4. ROOFCURB, GALVANIZED STEEL. 5. A17ACH WORK 10 uU6Bg TYPICAL (4) 510E5 4� 1 CRRFCURB002AO1 2 -0• (610) 0' -7/16 e SECT ION • _ _ C -C g (FLANGE OF DUCT E 7 05 CURB) DUCT 6. SER ICE CLEARANCE 4 FEET ON EACH SIDE. (FIELD SUPPLIED) 7. DIRECTION OF AIR FLOW. B. CONNECTOR PACKAGES CRBTMPWR00IA01 MO 2AD1 ARE FOR 1HRU- THE -CURB TYPE GAS PACKAGES CRBTMPWR003A01 AND 4601 ARE FOR THE THRU- THE - BOTTOM TYPE GA5 CONNECTIONS. , &, 1lZG.� ]1 COUNTER FLASHING (FIELD SUPPLIED) •00FING FELT (FIELD SUPPLIED) OPENING FOR BASEPAN ENTRY CANT STRIP SERVICE (SEE NOTE .8) (FIELD SUPPLIED) 0027 1/2 ROOFING MATERIAL (FIELD SUPPLIED) 0'-3 1/4 CONNECTOR PKG. ACC B C 0 ALT DRAIN HOLE GA5 POWER CONTROL ACCESSORY PMR SCALE 1,4 CRBTMPWROO1A01 CRB)MPWR002801 1 " -9 11 /16' [5511 1' -4' [406] 1 3/4"[44.5) 3/4'(191NPT 3/4- L191NPT 1 1/4 [31.7] 1/2 [12.71NPT I/2"(12.7]NPT CRBTMPWR003A01 1/2 %12.71NPT 3/4 %197NPT o CPBTMPWR004A01 3/4 "[191 NPT 1 1/4'31.71 \[83) [230) C SEE NOTE .2 - 1 1 RIGID INSULATION 1 (1 1EiD SUPPLIED) 1 GAS SERVICE 1 PLATE 1 (SEE NOTE .8) 1 L` 0' -4 3/I6 , [106] �. O [761 ' -I \\ C 5 / A \ \ / \\ 1 5 1 �)' ( -- ( I�7 1 - r` ; - ( ; - , \`( / / J / - - - - 0• -0 1/4'[7] 1' -4 13/16' (155)06 r►° \ (752] INSIDE) 0• -7 1/16' (INSIDE) 0• -4 9/16" ` \ J, ` \ ( 1 •. ...- / • 11� '\ SUPPLY AIR / , , % 1 RETURN AMRk [115.51 1 0 // I/71� TYP O� 2 3/13'- (611 'V I ''' VIEW -A -A- NERD OF BOLT TO BE ON \ /8 (1 RETURN AIR OPENING / INSIDE OF FLANGE 1 / 0•[48] /8' �i O• 2' -7 5 /B' [8037 1 " -1 7/16' [341] 8 SUPPLY AIR OPENING C - - - - , ` iUi 'B• 4. O[251 'A" I / • • `\ ��'` - ~� P� �� s -7 ve' y \\ /.::, 1 3 " -0 15/16' •• 077 3 [9381 , NOTE, CAMBRIOGEPORT 'SURE-LOCK' CORNER FASTENING DEVICE 15 ACCEPTABLE ALTERNATE CONSTRUCTION. 0' -0 7/16" [11) 0' -0 7/16' I [504116_e, (76]'m 3' -0' L 1'[738" L`Y 0'-0 11 ] 16 (BOLT HEADS) A 0' -0 7/15 REF (117 [9147 [117 A 1 (BOLT HEADS) (BOLT HEADS) tA VIEW /(TYP. ALL CORNERS) SEE VIEW "8 - -- A 9 Packaged Rooftop Builder 1.19x Page 4of7 Performance Summary For 5T Gas EIe -13 Seer Project: Armed Forces Recruit Prepared By: 06/24/2010 03:40PM Part N um ber:48TCDA06A2A5-0A0A0 ARI SEER. 13.00 Base Unit Weight. 619 lb Base Unit Dimensions Unit Length. 74.4 in Unit Width:.... 44.0 in Unit Height 33.4 in Unit Voltage- Phase - Hertz. 208 -3-60 Air Discharge. Vertical Fan Drive Type: Belt Actual Airflow. 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU /lb Evaporator Leaving Air DB: 57.9 F Evaporator Leaving Air WB: 57.3 F Evaporator Leaving Air Enthalpy: 24.56 BTU /Ib Gross Cooling Capacity: 61.90 MBH Gross Sensible Capacity: 47.70 MBH Compressor Power Input 4.43 kW Coil Bypass Factor: 0.055 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 97.3 F Gas Input Capacity: 72.0 MBH Gas Heating Capacity. 59.00 MBH Temperature Rise. 27.3 F Supply Fan External Static Pressure: 0.60 in wg Options / Accessories Static Pressure Economizer: 0.11 in wg Total External Static: 0.71 in wg Fan RPM: 1292 Fan Power: 1.30 BHP NOTE: Medium Static Fan Option Electrical Data Minimum Voltage. 187 Maximum Voltage. 253 Compressor RLA: 15.6 Compressor LRA: 110 Outdoor Fan Motor Qty. 1 Outdoor Fan FLA (ea): 1.5 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 5.2 Combustion Fan Motor FLA (ea): 0.24 Power Supply MCA: 26.2 Power Supply MOCP (Fuse or HACR)• 40 Min. Unit Disconnect FLA: 26 Min. Unit Disconnect LRA. 144 Packaged Rooftop Builder 1.19x Page 5 of 7 Performance Summary For 5T Gas EIe -13 Seer Project: Armed Forces Recruit Prepared By: 06/24/2010 03:40PM Electrical Convenience Outlet: None Acoustics Sound Power Levels, db re 10E -12 Watts Discharge Inlet Outdoor 63 Hz 87.9 87.5 84.0 125 Hz 83.1 80.1 82.2 250 Hz 76.1 67.2 76.3 500 Hz 71.8 64.4 74.8 1000 Hz 68.3 63.7 72.5 2000 Hz 62.7 57.8 68.8 4000 Hz 64.6 53.7 65.6 8000 Hz 60.2 46.4 61.8 A- Weighted 75.2 69.7 78.0 2.0 1.8 1.6 1.4 1.2 0, 1.0 U 0.8 0) 0.6 0.4 0.2 0.0 Fan Curve 1 0 RPM 00 RP 170 RPM 900 RP iNk111111 Lykyistim ii°0 RPM M. I MIN LI h. WAI 1111111■Itaillitint,..M6111 00 03 06 09 12 15 18 Airflow (CFM - thousands) RPM = 1292 BHP = 1.30 Maximum RPM = 1466 Maximum HP = 2.90 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point 21 24 27 Packaged Rooftop Builder 1.19x Page 6 of 7 • Project: Armed Forces Recruit Prepared By: Unit Feature Sheet for 5T Gas EIe -13 Seer 06/24/2010 03:40PM WeatherMaker — 48TC PACKAGED ROOFTOP GAS HEATING /ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5, 10, 12.5 TONS Optional Louvered Hail Guard Shown BRA ti COMPLIANT WEATHERMAKER SERIES WeatherMaker (48TC) units are one -piece gas heating, electric cooling units that are pre -wired and charged with Puron (R- 410) refrigerant. They are factory tested in both heating and cooling modes, and rated In accordance with ARI Standards 210 (04 -06 sizes) and 360 (07 -14 oizea). WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. 1 uion. Approved and certified by: C US .407,4 PI. drill Sizes 04-06 Sizes 07-14 Certified to ISO 9001:2000 STANDARD FEATURES INCLUDE: • Puron (R -410A) HFC refrigerant • ASHRAE 80.1 compliant and Energy Star qualified • Scroll compressors with internal line break and overload protection • Sing e-sage coating capacity control on 04-12 models • Two-stage cooling capacity oortrol on 08-14 models • SEER's up to 13.0. EER's up to 1 t.1 and IEER's up to 11.8 • AcutrolTM refrigerant metering system • Exclusive non - corrosive composite condensate pan in accordance with ASHRAE Standard Z. slopirg design. side or center drain • Standard cooing operation up to 115•F (46•C) and down to 40'F (4•C) - down to 25• F (-4• C) with winter start kit. • Pre- painted exterior panels and pFaner-coated interior panels tested to f00 hours salt spray protection • Fu8y insulated cabinet • Exclusive IGC solid -state control for on -board diagnostics with LED error code designation burner control logic and energy saving indoor fan motor delay • Low NOx models that meet CaSfomia Air Duality Management • Induced draft gas heat combustion design • Redundant gas valves with up to two stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: • Access panels with easy grip handles • innovative easy starting. no -strip strews on unit access panels • Two-inch disposable return air filters and Toot -less flter access door • Belt drive evaporator -fan motor and pulley oombinadons • New terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement • Exclusive IGC solid -state control for on -beard diagnostics with LED error code designation. burner control logic and energy saving indoor fan motor delay. INSTALLATION FEATURES: • Thru- the - bottom power entry capability • Single point gas and electric connections • Full perimeter base rail with btri:l-&1 rigging adapters and fork slots • Convertible from vertical to horizontal airflow for slab mounting STANDARD WARRANTY: • 10 -year heat exchanger - 1.° -year stainless steel option • 5-year compressor • 1-year parts • 3-year parts on Novation Condenser coils - where available • Many optional upgrades also available OPTIONS INCLUDE BUT ARE NOT UMITED TO: • PremierLink°' and Multi Protocol Direct Digital Controls (00C) • Suoply and Return Air Smote Detectors. high static motors • Lowered condenser coil guards • Ecrnorn er. disconnect and conven+ence outlet options • Stainless Steel heat exchanger option • Corrosion resistant pit coating_ • Exclusive Htmnid- MiZereadapave dehumidfication system available on at sizes - Motor Master I controller included For a complete list of options and accessories refer to the Product Data Catalog for this unit. Packaged Rooftop Builder 1.19x Page 7 of 7 • 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonres'dential Energy Code Compliance Forms Revised July 2007 Project Info Project Address ARMED FORCES RECRUITING Date 8/20/2010 16600 SOUTHCENTER PKWY For Building Department Use TUKWILA, WA 98188 Applicant Name: JOFFRE SECHIER Applicant Address: 6802 S. 220TH ST, KENT, WA 98032 Applicant Phone: 425 -251 -9840 FILE C :sPY 116 torte% REVIEWED FOR CODE COMPLIANCE SEP 0 8 2010 City of Tukwila BUILDING DIVISION ECEIVED AUG 2 0 2010 'ERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address ARMED FORCES RECRUITING Model No.1 Date 8/20/2010 Total CFM 16600 SOUTHCENTER PKWY SEER or EER For Building Dept. Use Location TUKWILA, WA 98188 CARRIER Applicant Name: JOFFRE SECHIER 4000 Applicant Address: 6802 S. 220TH ST, KENT, WA 98032 Applicant Phone: 425 - 251 -9840 110 Project Description Briefly describe mechanical system type and features. Includes Plans INSTALL (1) NEW 5 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER AND AIR DISTRIBUTION PER PLANS. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option Q Simple System Q Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name1 Model No.1 Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location RTU-1 CARRIER 48TCDA06 61900 4000 ECONO 13.00 59000 ROOF SPB -110 110 0.25 CV JANITORS CLOSET Heating Equipment Schedule Equip. ID Brand Name1 Model No.1 Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency° RTU -1 YORK 48TCDA06 59000 2000 ECONO 72000 59000 81.000 SPB -110 110 0.25 CV JANITORS CLOSET Fan Equipment Schedule Equip. ID Brand Name1 Model No.1 CFM SP1 HP /BHP Flow Control5 Location of Service EF1 &2 GREENHECK SPB -200 200 0.25 CV BATHROOMS EF3 GREENHECK SPB -110 110 0.25 CV JANITORS CLOSET 1lf available. 2 As tested according to Table 14 -1A through 14-1G. 31f required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: -i Constant vol? - Air cooled? J Packaged sys? <20,000 Btuh? 0 Split system? Economizer included? ./ If Heating Only: L <5000 cfm? <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START System Type Heating /Cooling or Cooling Only Air Cooled, Constant Vol? Heating Only Refere Section 1421 ingle Package Unit? plit Syste <= 84,000 Btuh? Econo ncluded? •ol Ca. <20,000 Btuh? Outd or Adjacent to utdoor of Ca <54,000 Btuh? otal Ca . wo economize <240,000 Btuh or 10 %? Simple System Allowed (section 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form _Mechanical Permit Plans Checklist__....___.. �___._.._..___MECH -CHK. Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address ARMED FORCES RECRUITING Date 8/20/2010 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule M2 yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M2 n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M2 yes 1412.2 Deadband control Indicate 5 degree deadband minimum M1 n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types M1 yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage M2 yes 1412.4.2 Optimum Start Indicate optimum start controls yes 1412.5 Heat pump control Indicate microprocessor on thermostat schedule Ml n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes .1412.7 Balancing Indicate balancing features on plans M2 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule M2 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M2 n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb M1 n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling Ml n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M1 yes 1414.2 Duct insulation Indicate R -value of insulation on duct M1 n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan Ml yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing Mi yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training Ml yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M1 n. a. 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover If no is circled for any question, provide explanation: r August 24, 2010 • it lla. • Jim Haggerton, Mayor Deprtne, r t of Community Development Joffre Sechier Comfort Mechanical 6802 S 220 St Kent, WA 98032 RE: Letter of Incomplete Application # 1 Mechanical Permit Application M10 -115 Armed Forces Recruiting Center —16600 Southcenter Py Dear Mr. Sechier, Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 20, 2010 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a "Revision Submittal Sheet" must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician Enclosures File: M10 -115 W:\Permit Center \Incomplete Letters\20 I 0\M 10 -115 Incomplete Ltr # 1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: August 24, 2010 Project Name: Armed Forces Recruiting Center Permit #: M10 -115 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide engineers calculations and analysis of the roof system to verify the roof structure sufficient for supporting the new mechanical equipment combined with all mechanical components. Engineer's calculations and plan drawings shall be wet stamped and signed by the design professional providing the plans and documents. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. *PERMIT C RD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -115 DATE: 09/02/10 PROJECT NAME: ARMED FORCES RECRUITING CENTER SITE ADDRESS: 16600 SOUTHCENTER PY Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # after Permit Issued DEPARTMENTS: I1. ing�DiVision , Public Works F ri e'Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 09/07/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required n No further Review Required Y,1, DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 10/05/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • r • PER t; PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -115 DATE: 08 -20 -10 PROJECT NAME: ARMED FORCES RECRUITING CENTER SITE ADDRESS: 16600 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works 1 Fire Prevention Structural 1 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08-24 -10 Not Applicable Comments: Permit Center Use Only ��jj �``_ INCOMPLETE LETTER MAILED: ail-144 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:, TUES /THURS ROUTING: Please Route Structural Review Required nNo further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions DUE DATE: 09-21 -10 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 9/(Q/to Plan Check/Permit Number: M 1 0— 1 1 5 Response to Incomplete Letter # 1 E Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Armed Forces Recruiting Center Project Address: 16600 Southcenter Py CITY R nF LA SEP 0 2 2010 ` Q PERMIT CENTER Contact Person:T � Phone Number: Summary of Revision: Lio Sheet Number(s): S —D 3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople P ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL INC UBI No. 601954041 Phone 4252519840 Status Active Address 6802 So. 220Th Street License No. COMFOMI015LA Suite /Apt. License Type Construction Contractor City Kent Effective Date 6/1/1999 State WA Expiration 6/1/2012 Date Zip 98032 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM'010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/19994/30/2012 Active COMFOP'064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat ,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 06/01/2005 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Amount JACKSON, HERB J Vice President 01/01/1980 9849307 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS Et SURETY OF MD LPM4041162 06/01/2002 Until Cancelled $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 FEDERATED MUTUAL INS CO 9849307 06/01/2010 06/01/2011 $1,000,000.00 05/03/2010 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.00 05/01/2009 6 FEDERATED SERV /MUT INS CO 9849306 06/01/2005 06/01/2006 $1,000,000.00 04/25/2005 5 FEDERATED MUTUAL INS CO 9849306 06/01/2004 06/01/2005 $1,000,000.00 04/30/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/Ini/bbip/Print.aspx 09/08/2010 PARCEL DATA Parcel 262304 -9137 Name PARKWAY SQUARE Site Address 16600 SOUTHCENTER PKWY 98188 Geo Area 70 -50 Spec Area 0 -0 Legal Description BEG SE COR OF SE 1/4 OF NW 1/4 TH N 89 -43 -19 W 619.81 FT TH N 0 -57 -48 W 378.74 FT TO TPOB TH CONTG N 0 -57 -48 W 114.02 FT TH S 89 -45 -58 E 260 FT TH S 0 -14 -02 W 114 FT TH N 89 -45 -58 W 257.62 1FT TO TPOB AKA POR PARCEL 3 OF CITY OF TUKWILA SHORT PLAT NO 77 -51 RECORDING NO 7710130634 - AKA PARCEL A OF CITY OF TUKWILA BINDING SITE PLAN, PARKWAY SQUARE, I RECORDING NO 7912050783 Jurisdiction Levy Code Propert Type Plat Block / Building Number Plat Lot / Unit Number Quarter - Section- Township -Range ASSESSOR DATA AREA OF WORK 4C) 2010 King County 01. The kdorr atton InCWded on tharrt�'!ap ha0 been compiled, by King Copntyatad:rom a yanrty of saurees and is subject to change without notice. King e e" elfne c te.to -useofsuch :I formatto County makee no're roaentatlong oil± rreatea eipress;orimptled as.lo ecouraeyi oornpbten a ,sitlf sa,o t:gti the n n 11q3 deetlmeiit lea i(deiided'for ep; ;illyey:product';KInpo Counttyyphall not be 14bNe for any;genprat, speclaI. k direct, IScklsntat,'or consequential datnaga; lndu4ing ut not Qtn edtoi b;t fevenuee orlesrprofltt resuJti :froth the use • mtsuaeec9f e`Fir armaUosr Cm) tsltgd on this,rnap Any dale oft • Jtit arinfon ononS+tsrne ohl� df.xc pjby tegFP Is&an ?tMWCerrnry ., u�Y...f. pa a l3nonolop Sd King County MAP�`i r pe lr ctmauon (http J /wwit,meuoKO.go�({3(${IhMt‘P SITE PLAN GENERAL NOTES: 1. All WORK PER CURRENT CODES. 2. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 3. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 4. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 5. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. 6. SEAL TRANSVERSE DUCTJOINTS WITH APPROVED MASTIC. 7. INSTALL R -8 INSULATION ON DUCT IN UNCONDITIONED SPACE. 8. AIR BALANCE SYSTEMS PER CFM NOTED ON PLANS. 9. PROVIDE AIR BALANCE AND COMMISIONING REPORT. 10.INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 11.INSTALL RETURN AIR DUCT SMOKE DETECTOR FOR UNITS WITH GREATER THAN 2,000 CFM. 12.ROUTE CONDENSATE TO SPLASH BLOCK. PROJECT DESCRIPTION: 1. REWORK EXISTING AIR DISTRIBUTION FROM (4) EXISTING ROOFTOP UNITS PER PLANS. 2. INSTALL NEW FLEX DUCT, GRILLS, AND DIFFUSERS AS NECESSARY FOR NEW FLOOR PLAN. 3. INSTALL (1) 5 -TON GAS PACKAGED ROOFTOP AIR CONDITIONING UNIT WITH ECONOMIZER. 4. INSTALL COMPLETE SUPPLY AND RETURN AIR DISTRIBUTION TO PROVIDE FOR (2) TEMPERATURE ZONES INCLUDING GRILLS AND DIFFUSERS. 5. INSTALL (5) NEW 7 -DAY PROGRAMMABLE THERMOSTATS, 6. INTALL (2) 200 CFM AND (1) 100 CFM EXHAUST FAN FOR BATHROOMS AND JANITOR'S CLOSET. VENT THRU ROOF. 7. REMOVE (1) EXISTING REZNOR 75,000 BTUH GAS UNIT HEATER. 8. REROUTE EXISTING GAS PIPE FROM UNIT HEATER TO (N) ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT. 9. LABEL UNITS PER PLANS. 154 k1fat Dr thl i''nr s 164th St U: CD 3 S167th St . 3168th St ....0 s 170th St Wig Blvd ndSt:;'r: .... ... ... Ind. PI; mapquest , 200 m '.01 1'600fj'. VICINITY MAP Baker Blvd l Strander Blvd Miinkler Blvd ®2010 MapQue ,T o01 ®201 iNlAVTEQ, Interrnap . SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical (Plumbing 5Kas Piping City of Tukwila k I...Oj Q ENVISION REVISIONS No changes shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: R visions will require a new plan submittal and may include additional ptan.review fees. Permit N®.. MtO. 115 Plan review approval is subject to errors and omissions. Apron! of construction documents does not authorize ihE violation of any adopted code or ordinance. Receipt of approve cfie)lCopy and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPWA!!Ep SEP 0 8 2010 A-3 U42- City of Tukwila BUILDING DIVISION M1Ol5 RECEIVED AUG 20 2010 PE CENTER ENTER I 1 REVISIONS MECHANICAL, COMFORT F. 4-25.251.9871 0 N vi 0 40 I°o to Z H Y w � � Z T"" W (c)C33 III F- 0 0J WS Y Q (r) DATE : 8 -20 -10 SCALE * DRAWN * JTS CHECKED: • M1 00 -000 • I8' -0` I1$_61 31'-6' 44" OPEN WEB TRUSSES AT 32 "o.c. (E) 5 1/8x12 GLB SE) SEE NOTE 5 -J CO 12 0 "f -H %j X 00 i 5 1/8x12 GLB (E) 5 1/8x12 GLB (E) C13 0 N X 0o LO NEW MECH. UNIT (684 Ibs) PARTIAL ROOF FRAMING PLAN 1/4. =1' —O" m CITY OF TN II:A SEP 0 2 2010 PERMIT CENTER NOTES: REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 8 2010 City of Tukwila BUILDING DIVISION EXPIRES j l . Z'.. J J 1. CONTACTOR TO VERIFY ALL SIZES, DIMENSIONS, AND LOCATION OF THE MECHANICAL UNIT AT FIELD. 2. CONTRACTOR TO VERIFY MEMBER SIZES. 3. CONTRACTOR TO VERIFY AND LOCATIONS. 4. EXISTING: (E) NEW: (N) 5. H.S.S. 4 "x4 "x1 /4" STRONG BACK TO BOND BEAM BELOW THE ROOF 0 C.M.U. WALL. ALL EXISTING ROOF FRAMING MECHANICAL UNIT SIZE, WEIGHT INCOMPLETE LTR# �_.. 6. SEE SHEET S -3 FOR MECHANICAL UNIT CONNECTION DETAILS. I�IIIO -III tij 0 um IL g Let IC E 2°1 11-1 Li O SHEET S -2 JOB # 108 -1009 +- N 1+) ■ 4 - 1 ri " ft • tij 0 um IL g Let IC E 2°1 11-1 Li O SHEET S -2 JOB # 108 -1009 MECH. UNIT' (684 # MAX. �wiwwwi �wwwiw. �wwwwi 111151■�►wi� �wwwi� -n l 1 SEE DETAILS -2, 3/S -3 �� 2x4 LOAD TRANSFER BLOCK PER DETAIL -3/S -3 TYP. MECH. UNIT ELEVATION VIEW 2x8 LEDGER w/ (3) -16d SCALE: 5/4"=1'-0" EXIST. 40" DEEP TRUSS 0 24 "o.c. 0 LOAD TRANSFER BLOCKS & 16d 0 9 "o.c. 0 TOP CHORD (NO NAILS WITHIN 6" OF ROOF TRUSS PINS) 2x4 LOAD TRANSFER BLOCK 4x6 w/ SIMPSON U46 HANGER EACH END ROOF EQUIPMENT SUPPORT DETAIL MECH. UNIT PER ROOF PLAN PRE —FAB METAL CURB ATTACH TO MECH. UNIT PER MFG (4 — #12 SCREWS MIN. EA. SIDE) (4) — #12 SCREWS EA. SIDE OF THE CURB (MIN. ATTACHMENT) OOF PLYWOOD 4x6 OR TOP CHORD OF THE TRUSS CURB / ROOF ATTACHMENT r ia SIMPSON H mTTS HOLDOW N PER FOUND. PLAN ti- SCALE: 3/4"111s-0 4x6 POST HOEDOWN DETAIL 5/8 "0 HILTI H.A.S. ROD (EMBED. 4 ") W/ HY150 MAX —SD EPDXY MI6-- 115 REVIEWED FOR CODE COMPLIANCE APPP(MIED SEP 0 8 2QMQ City of Tukwila BUILDING DIVISION CmOFETUI(WH,q SEP 02 2010 PERMIT CENTER TONAL `EXPIRES ) / SHEET S -3 JOB # 108 -1000 e- N M '' SHEET S -3 JOB # 108 -1000