Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M10-125 - BELFOR PROPRTY RESTORATION
BELFOR PROPERTY RESTORATION 4320 S 131 PL M10 -1252 City oiTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 7349200095 Address: 4320 S 131 PL TUKW Project Name: BELFOR PROPRTY RESTORATION Permit Number: M10 -125 Issue Date: 10/05/2010 Permit Expires On: 04/03/2011 Owner: Name: NORMED SHAW PTN Address: PO BOX 3644 , SEATTLE WA 98124 Contact Person: Name: KEVIN FLORES Address: 7845 E REDFIELD RD , SCOTTSDALE AZ 85260 Email: ESTIMATING @SUNSTATEMECHANICAL.COM Contractor: Name: THE G R A Z A K CORPORATION Address: 21639 N 14 AV , PHOENIX AZ 85027 Contractor License No: GRZKCGR912QQ Phone: 480 201 -6921 Phone: 623 - 535 -5905 Expiration Date: 12/14/2011 DESCRIPTION OF WORK: INSTALLATION OF (2) COMPLETE 7.5 TON PACKAGE HEAT PUMP SYSTEMS, AIR DUCTING, GRILLES, CONTROL WIRING, (2) THERMOSTATS, EXCHANGE DUCT FOR BATHROOM FANS AND CONDENSATE PIPING. Value of Mechanical: $29,850.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $551.06 International Mechanical Code Edition: 2009 Date: I /� I V IV- S I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: /"r S .r btA,s7t Sr. Date: (O - f P This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -125 Printed: 10 -05 -2010 • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 7349200095 Address: Suite No: Tenant: 4320 S 131 PL TUKW BELFOR PROPRTY RESTORATION Permit Number: Status: Applied Date: Issue Date: M10 -125 ISSUED 09/20/2010 10/05/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Thkwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC doc: Cond -10/06 M10 -125 Printed: 10 -05 -2010 104.2) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -125 Printed: 10 -05 -2010 • City of Tukwila �y Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. ,;S Tr (,// 'j- Sr. Signature: Print Name: Date: /° doc: Cond -10/06 M10 -125 Printed: 10 -05 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. 1/17/? /C: Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 5 , l•'3 1%k" Pc_ ge ) 9 King Co Assessor's Tax No.: La -i Ae a qi- Suite Number: Tenant Name: B F.l, OK„ P Racra,T9 �iroRATbo�.; Property Owners Name: LAr &:1 5 {rktAtJ Mailing Address: 2.0. $01- 34.,-N Floor: New Tenant: liZ Yes ❑..No 1, T LE City IA) A• State Ret ,2t{ Zip CONTACT PERSON Who do we contact when your permit is ready to be issued Name: ,Ewn1 Ct.°(ZES Mailing Address: L� £ • € t4 tub . E -Mail Address: e...40-4- ...40 �a�'►kq 8 SwnS+aAernCGIACu+tGGG Day Telephone: LOW aV I. VOA City State Zip COI" Fax Number: LO 141g (0.2 MECHANICAL CONTRACTOR INFORMATION Company Name: 6(2.11^ PAL C-og -P -. Mailing Address: 02(t (0 ? J q l i ' ((-14 raj• Contact Person: V.)E 44 E -Mail Address: 021 OOq2.11 Contractor Registration Number: PNb IY- A gso2� City S-1-6,14 ate Zip Day Telephone: (�3 858 Fax Number: (o a3 63S' Si4ol Expiration Date: &(a'{ ig-Otl ARCHITECT OF RECORD - Ail plans must be wet stamped by Architect of Record Company Name: T ft'St, f) Ruz Mailing Address: rt.( (o EoNAIR DR, S. J Contact Person: i'w% 6 1644 ix. E -Mail Address: dkehC (!' ce.ke: kar • Coo.% 5 CATTLE w �'t8c(C City ,,�/ ' State Zip Day Telephone: `4 s 3 ? Fax Number: et (=G. o7 '(` $'3c ? ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: ot.S ASSoctATES Xt. I !S - 0 RC l�M-t . O w DR. P t!0€.1.l,x AZ.. Asa,)-0 Contact Person: (V■A -111(- -QET€(LSvti E -Mail Address: (hark() 117 ?e. Cor6t.t (1 . ce,AA. H:\Applications\Forms- Applications On Line \2009 Applications \I -2009 - Mechanical Permit Application doc Revised: 1 -2009 bh City State Zip Day Telephone: Co d0Z' jq 3 . '-U ( . Fax Number: (70 2 - 025 Page 1 of 2 IDate Application Accepted: Valuation of Project (contractor's bid price): $ c - lI 3>,5-"b o Scope of Work (please provide detailed information)::3.7.Sr UAH'Clon) 6P () Cchivk-PlALM 7. 5 r PP►Cc-A-( 14f -A Nr1/4P 5M fj,(L- 4,4-cr ►A,G CIRtLk- , co,. rant, w,(4,e4 62) Tt 0S-t4 t Ext}- Pt& t S A-1-30 P►,6 Use: Residential: New Commercial: New ❑ Replacement Replacement ❑ 0 Fuel Type: Electric E. Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser q n 3 -15 HP /500,000 BTU n _ e� Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP/1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE RY B HE _.: - - HE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: R OR A Date: C / 0 Print Name: Day Telephone: 6 .2.3 - q 5S— c -1 (7�" Mailing Address: 2Q S• c - p--FL-P t EV ().. City State Zip Date Application Expires: H: \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 7349200095 Permit Number: M10 -125 Address: 4320 S 131 PL TUKW Status: PENDING Suite No: Applied Date: 09/20/2010 Applicant: BELFOR PROPRTY RESTORATION Issue Date: Receipt No.: R10 -01858 Initials: TLS User ED: 1670 Payment Amount: $551.06 Payment Date: 09/20/2010 08:54 AM Balance: $0.00 Payee: HALFON CONSTRUCTION CO/ TODD HALFON TRANSACTION LIST: Type Method Descriptio Amount Payment Check 14612 551.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 440.85 000.345.830 110.21 Total: $551.06 PAYMENT RECEIVED doc: Receiot -06 Printed: 09 -20 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line. (206) 431 -2451 Pro' t: 461-1 Type of Inspect 'on: *till_ a Addre ,(� Date Call 1. A, ( Special-Instructions: Date Wanted: a.m. Requester: - Phone No: - proved peF applicable codes. -I: Corrections required prior to approval. • COMMENTS: 4*&&i* H,Ek `L R rOLICS),_ . $t, z i)w'\ wn Me t- rerk pCe Inspgftor: Date: REINSPECTION FEE REQUIRED. P ior to next inspection. fee must be- - paid at.6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. �.�••:• INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO -- . CITY OF TUKWIL-A• BUILDING DIVISION V. 6300 Southcenter Blvd.; #100; Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 OttO42- Approved per applicable codes. Corrections required prior to approval. • COMMENTS: Type of Ins ction: cm..4 ,E_..5 v dc,� ect: —+ ; , , -111.4-! • im Address: S� i 3( Pty 43/2A3 /- Date Called h A4 4 Special Instructions: . i A- Date Wanted: r a�.,m.... i •m• Requester: CO Kf y Phone ? CU d 4, 3 .36-6 Approved per applicable codes. Corrections required prior to approval. • COMMENTS: • _C)k6V. . .- oar D flizioc..-K-1:v%-i pn)p..er, _ F..:to it diet& -c-‘)1-1- 1 u - ,. f i e.-4.,...1-7))/1 , (K 11, CO Kf y t A. vi r AC—. c )--, ))t/I 0 .z..,-) t r e--45 7 .)/ Mct - e <f f ___ A;(1- p) e AID 1Inspe a or: 1Date: 1 . r 1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION REC ORD Retain a copy with. permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 - Pro'ect: v f Type of Inspection: —...—A, Address: ...1=- Date Called?` • 5 e.6' aPlns uctions: 44 ! 45- - c)I . Date Wanted: /rte a : ' S :If cd Requester: Phone No: ra 144 Approved per applicable codes. a Correctioris required prior.to approval. COMMENTS: • n REINSPECTION FEE REQUIRED. Prior to next.inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r-' - - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 --125 Pr ect: pp ...- j Typkof Inspection: Address: ,. Date C d: Special Instructions: . / • Date Wanted: .m.. / 0 ' f ' –i0 p.m. Requester: . Phone No: Co 23 —?04 --a:)-r, 87 Approved per applicable codes. a.Corrections required prior to approval: • pOMMENTS: [insPe4r: Date: 0 -/1 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. .. INSPECTION RECORD ' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 ' Permit Inspection Request Line (206) 431 -2451 • P oject` ��,` .t// �pv 1Z� , I () r per G7 ! -e. P , r Typ �o+f Inspection: ^ c_ Y1 - — '( ' �""' • ddress: 326 S. .1p S'1�a 13r - Date Called: Special Instructions: Special Date Wanted: 0'-- � am CO -4-0 ^(0 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: • . • t. • --- -.. Inspec or I Date: - i. Jr 1 REINSPECTION.FEE REQUIRED.. Prior to ext inspection, fee must be paid at 6300 Southcenter Blvd.. Suite f100. Gall to schedule reinspection. • • FILE C PY Permit No. REVI ►�.ti!- CODE ': F APPRAVED PARTIAL ROOF FRAMING PLAN Pacific Engineering Technologies SCALE: I/8" • 1' -0" • OyM - 1 011j 28:Sub 100 few 207] 2D2- 46,109 -3342 ,80Q- . () 621 -730b NEW (2) 2x6 ATTACHED TO EXIST. SINGLE 2x6, TYP. APPROXIMATE LOCATION OF EXIST. SPRINKLER PIPE (SHOWN DASHED) EXIST. 2x6, TYP. NEW (2) 2x6, TYP. (3) PLACES. PROVIDE LUS26 -2 HANGERS EACH END EXIST. STEEL GIRDER TRUSS NEW (4) 2x6 ROOF JOISTS LOCATE THE MEMBERS A5 REQ'D TO FIT NEW 1NVAC UNIT AND AVOID EXIST. STEEL BRIDGING NEW (2) 2x6. TYP. (3) PLACES. PROVIDE LU926 -2 HANGERS EACH END NEW (4) 2x6 ROOF JOISTS MATE LOCATIONS OF TS, SKYLIGHTS, ETC. City of Tukwila BUILDING niiicinN JOB No 1020900 --SHEET-1--OF 2 ,n8 ma, BELFOR TENANT IMPROVEMENTS - HVAC UNIT SUPPORT / CONNECTION PROJECT NARRATIVE, PARTIAL FVCF FRAMING PLAN 4 SECTION COUP Em N. SHERSTHA m„r 9/18/10 ,.,. Bf MP$ PROJECT NARRATIVE THE PURPOSE OF THESE DRAWINGS IS TO SHOW THE STRUCTURAL ROOF FRAMING MEMBERS TO SUPPORT THE PROPOSED ROOF -TOP NVAC UNITS AT THE NORTH BUILDING AT 4320 S. 131.1. PLACE, TUKWILA, WA - NEW WAREHOUSE / OFFICE-NOR-ED II AND THE CONNECTION OF THE UNIT MANUFACTURER'S CURB TO THE WOOD FRAMING. ARCHITECTURAL DETAILING SUCH A5, BUT NOT LIMITED TO, ROOFING, WATERPROOFING, FLASHING, VENTILATION, INTERIOR FINISHES, INSULATION, ETC, 15 NOT INCLUDED IN THESE DRAWNGS. MECHANICAL WORK, ELECTRICAL WORK AND DESIGN OF THE CURB SUPPORTING. THE UNIT IS NOT PART OF OUR SCOPE OF WORK. REFER TO DRAWINGS TITLED "PROPOSED TENANT IMPROVEMENT, For BELFOR PROPERTY RESTORATION" BY DAVID KEHLE (DK) ARCHITECT DATED 3- 01 -10, WITH REVISIONS THRU 6 -I6 -10 FOR ADDITIONAL INFORMATION, PLANS, NOTES, DETAILS, GRID INFORMATION, ETC. RELATED TO THE TENANT IMPROVEMENTS. ORIGINAL CONSTRUCTION DOCUMENTS RELATED TO THE STRUCTURE ( "PROPOSED NEW WAREHOUSE/OFFICE- MOWED II: for NORMED -61-1AW PARTNERSHIP) BY RICHARD HUDSON 4 ASSOCIATES, INC. - CONSULTING ENGINEERS AND DK ARCHITECT, DATED 11- 18 -04, WERE ALSO REVIEWED. EXIST. ROOF SHEATHING SIMPSON .434 CLIP, TYP. (3) PLACES �i IS /0 RLCEIV CITY OFTUT ='LA SEP 20 2010 PERMIT CENTER EXIST. WOOD FILLER MEMBER ON TOP OF TRUSS TOP CHORD OF XIST. STEEL TRUSS EXIST. STEEL TRUSS WEB MEMBERS SECTION _ SCALE: 11/2" • I' -0" 1 NEW (4) 2x- JOISTS PER PLAN. NAIL TOGETHER PER SECTION 2 2 WATERFROOFING 4 INSULATION NOT 54401U,1 FOR CLARITY ALL NFOF!•IAT'ION ON THIS COGB"ENT IS THE EXCLUSIVE PROPERTY OP PACIFIC EI NEERN8 TECHNOLOGIES, NG, Q COPTRJGHT 2010 EXISTING 2246 AND 4xS EXISTING 2216 AND 4x8 EXISTING 23yb AND 4x8 LEXISTING EXISTING 1700 B w AT 48" 0. 48" O.G. APFROX. LOCAT NVAC UNIT. AL NAT THE DUCT • MISS NE SF- i LINES BELOW NEW 2x6 ATTA EXIST. 2x -, TYP. EXIST. 2x• JOIST. GUT FOR NEW H V A C WIT ••• HANGERS F1'R - (2)H�T1 FOR AT 48" O.C. EXIST. 2x6 AT 20—ec. 2x6 AT 24" OTC. I SKYLIGHT • OF NEW UNIT SUCH ' = INGS ER PIPE TYP. 3 2 — ► ED TO REQD • a b AT NEW;I 2 / 2 / I \�, 4y_ -11 T + // q 9 —., IS 7- Q m 1 W 44)) O W FOR LOCATE CENTRAL DUCTTOPENINGS EXIST. METAL STLD FRAMING BELOW EXIST. 2x- JOIST. CUT FOR NEW NVAC UNIT FRAMING. PROVIDE sfl SSON U.026 HANGERS FOR SUPPORT (2) NS. TTp 0 TYP. SIM r--- W - — — 1 (2) 4G I - O ........- WALL I -_•, ,.�_I --' ( r i 9 I+ ,g AS RE= AT N311 Q R J w N N W nt _ �I NOTE: APPROXI N$VOAC I �✓ EXIST. SKYLIGHT i 0 'LIANCE IUTALL. BUILDING ENTRY SCALE: I/8" • 1' -0" • OyM - 1 011j 28:Sub 100 few 207] 2D2- 46,109 -3342 ,80Q- . () 621 -730b NEW (2) 2x6 ATTACHED TO EXIST. SINGLE 2x6, TYP. APPROXIMATE LOCATION OF EXIST. SPRINKLER PIPE (SHOWN DASHED) EXIST. 2x6, TYP. NEW (2) 2x6, TYP. (3) PLACES. PROVIDE LUS26 -2 HANGERS EACH END EXIST. STEEL GIRDER TRUSS NEW (4) 2x6 ROOF JOISTS LOCATE THE MEMBERS A5 REQ'D TO FIT NEW 1NVAC UNIT AND AVOID EXIST. STEEL BRIDGING NEW (2) 2x6. TYP. (3) PLACES. PROVIDE LU926 -2 HANGERS EACH END NEW (4) 2x6 ROOF JOISTS MATE LOCATIONS OF TS, SKYLIGHTS, ETC. City of Tukwila BUILDING niiicinN JOB No 1020900 --SHEET-1--OF 2 ,n8 ma, BELFOR TENANT IMPROVEMENTS - HVAC UNIT SUPPORT / CONNECTION PROJECT NARRATIVE, PARTIAL FVCF FRAMING PLAN 4 SECTION COUP Em N. SHERSTHA m„r 9/18/10 ,.,. Bf MP$ PROJECT NARRATIVE THE PURPOSE OF THESE DRAWINGS IS TO SHOW THE STRUCTURAL ROOF FRAMING MEMBERS TO SUPPORT THE PROPOSED ROOF -TOP NVAC UNITS AT THE NORTH BUILDING AT 4320 S. 131.1. PLACE, TUKWILA, WA - NEW WAREHOUSE / OFFICE-NOR-ED II AND THE CONNECTION OF THE UNIT MANUFACTURER'S CURB TO THE WOOD FRAMING. ARCHITECTURAL DETAILING SUCH A5, BUT NOT LIMITED TO, ROOFING, WATERPROOFING, FLASHING, VENTILATION, INTERIOR FINISHES, INSULATION, ETC, 15 NOT INCLUDED IN THESE DRAWNGS. MECHANICAL WORK, ELECTRICAL WORK AND DESIGN OF THE CURB SUPPORTING. THE UNIT IS NOT PART OF OUR SCOPE OF WORK. REFER TO DRAWINGS TITLED "PROPOSED TENANT IMPROVEMENT, For BELFOR PROPERTY RESTORATION" BY DAVID KEHLE (DK) ARCHITECT DATED 3- 01 -10, WITH REVISIONS THRU 6 -I6 -10 FOR ADDITIONAL INFORMATION, PLANS, NOTES, DETAILS, GRID INFORMATION, ETC. RELATED TO THE TENANT IMPROVEMENTS. ORIGINAL CONSTRUCTION DOCUMENTS RELATED TO THE STRUCTURE ( "PROPOSED NEW WAREHOUSE/OFFICE- MOWED II: for NORMED -61-1AW PARTNERSHIP) BY RICHARD HUDSON 4 ASSOCIATES, INC. - CONSULTING ENGINEERS AND DK ARCHITECT, DATED 11- 18 -04, WERE ALSO REVIEWED. EXIST. ROOF SHEATHING SIMPSON .434 CLIP, TYP. (3) PLACES �i IS /0 RLCEIV CITY OFTUT ='LA SEP 20 2010 PERMIT CENTER EXIST. WOOD FILLER MEMBER ON TOP OF TRUSS TOP CHORD OF XIST. STEEL TRUSS EXIST. STEEL TRUSS WEB MEMBERS SECTION _ SCALE: 11/2" • I' -0" 1 NEW (4) 2x- JOISTS PER PLAN. NAIL TOGETHER PER SECTION 2 2 WATERFROOFING 4 INSULATION NOT 54401U,1 FOR CLARITY ALL NFOF!•IAT'ION ON THIS COGB"ENT IS THE EXCLUSIVE PROPERTY OP PACIFIC EI NEERN8 TECHNOLOGIES, NG, Q COPTRJGHT 2010 PREFABRICATED STEEL CURB BY HVAC - - - -` UNIT MANUFACTURER WOOD CURB INSERT NEW 1/4"4, COUNTERSUNK LAG SCREWS AT 16" O.C. PROVIDE SCREW LENGTH TO HAVE 2" MIN. PENETRATION INTO 2x- BELOW. CONTRACTOR TO VERIFY LAG SCREWS AT MIDDLE OF 2x- BELOW. COUNTERSINK AS REDID NEW 12) 2x- PER PLAN. CONNECT TO EXIST. 2x- W/ (2) ROWS OF I6d NAILS AT I_" 0.C. STAGGERED EACH SIDE MECI4. UNIT BY OTHERS No. 12 x 2" LONG GALV. WOOD SCREWS AT I' -0" O.C. HTAPERED 4x- WOOD 514111 (MIN. 1 1/2" TALL) TO LEVEL N /AC UNIT AS REQ'C• BY H /AC UNIT MANUFACTURER ,—J EXIST. ROOF S4EATNING _NEW 2x- ROOF JOIST PER FLAN. I. EXIST. 2.6- ROOF JOIST PER PLAN. rJNEW (4) 2x- PER PLAN AT 51M. SECT. ATTACH W/ (2) ROWS OF 16d NAILS A7 12" O.C. STAGGERED EA. SIDE SECTION 12.1 SCALE: 1 1/2" • 1' -0" EXIST. ROOF SHEATHING f1� NEW 2x- JOIST PER PLAN. CONNECT TO EXIST. FILLER WI SIMPSON 434 CLIP LLOTE: WATERPROOFING, INSULATION AND CANT STRIP NO7 61.4011N FOR CLARITY _ EXIST. WOOD FILLER MEMBER ON TOP OF TRUSS EXIST. 2x- JOIST W/ TOP I j FLANGE HANGER 1./5-./0 P g01e3' 9 .22L •a e. SECTION L _! SCALE: 11/2" • I' -0" TOP CHORD OF EXIST. STEEL TRUSS EXIST. STEEL TRUSS .r' I 11.E3 MEMBERS NEW (2) 2x- JOISTS PER PLAN. CONNECT TO EXIST. FILLER W/ SIMPSON 434 CLIP. NAIL TOGETHER PER SECTION _J NOTE : WATERPROOFING 4 INSULATION NOT SHOUNI FOR CLARIT1' REVIEWS Pacific Engineering • ..670 ..ner. A..we Aa.6 - Sat BIB Ss<.. 1,11,260t7 n 96:69 -7... 7r.'P+w 'f06) 26. -7:C rasa.. 17061 79 -:511 .04o.n:1• (6A] 671-7- ALL Q•FORMATIQN ON 11.416 DOCUMENT 16 THE EXCLUSIVE PROPERTY OF PACFIC E1- b44EER:NG TF_CHNO OGIES, h40, .o. COPYRIGHT 2010 009 .A Joe F A.E: 10209.00 sway 2 2 EELFOR TENANT IMPROVEMENTS - I.IVAC UNIT SUPPORT / CONNECTION MATERIAL SPECIFICATIONS 4 SECTIONS tow N. 51- IERSTHA MATERIAL SPECIFICATIONS WOOD SCREW'S: UbOD SCREWS SHALL CONFORM TO AN51 /ASME STANDARD 818,6.1 -1981. WOOD SCREW DIAMETERS SHALL BE AS FOLLOWS: NO. 8 0.164" DIAMETER NO. 10 0.190" DIAMETER NO. 12 0216" DIAMETER REFERENCE DRAWINGS FOR MINIMUM SCREW LENGTHS. LAG SCREWS: LAG SCREWS SHALL CONFORM TO ANSI!ASME STANDARD 5I82.1 -1981. REFERENCE DRAWINGS FOR MINIMUM DIAMETER AND SCREW LENGTHS. EAir 9/15/10 .'6-K. By MP5 NAILS: ALL NAILS 51 -1ALL BE COMMON NAILS UNLESS OTHERWISE SPECIFIED OR APPROVED BY THE ENGINEER PRIOR TO CONSTRUCTION. NAILING SHALL BE IN ACCORDANCE W/ NAILING SCHEDULE TABLE 2304.9.1 IN THE IBC 2006 EDITION. 8d COt -ITION 2 1/2 "x .131 DIA. Wi 9/32 DIA. HEAD 1Od COMMON 3 "x .148 DIA. W/ 3/16 1)14. HEAD 16d COMMON 3 1./2 "x .162 DIA. W/ I1/32 DIA HEAD SUBSTITUTION OF BOX OR COOLER NAILS I5 NOT ACCEPTABLE. LIGHT GAUGE FRAMING: CONNECTORS: NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS AND OTHER CONNECTING DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY THE SIMPSON STRONG -TIE COMPANY, DUBLIN, CALIFORNIA. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY HAVE CO =B APPROVAL FOR EQUAL LOAD CAPACITIES. METAL HANGERS SHALL BE FASTENED TO THE SUPPORTED MEMBER USING THE NUMBER OF FASTENERS CALLED FOR BY HANGER MANUFACTURER STRUCTURAL LUMBER 4 TIMBER: ALL LUMBER SHALL BE GRACED M ACCORDANCE WITH CURRENT WllPA STANDARD GRADING RULES FOR WESTERN LUMBER USE THE FOLLOWING SPECIES AND MINIMUM GRADE. JOISTS AND WOOD 51.4111 DOUG -FIR LARCH 62 Fb •900 PSI ROOF-B14PJlRAGM NAILING: Fr�PANEL EDGE NAILING- AROUND NEW OPENINGS (MIN. l0d COMMON NAILS AT 6" �j ' L SUPPORTED PANEL EDGES AND FIELD NAILING (MIN. 10d NAILS AT 12" O.G.) CODECOM LIANC .1EDIATE SUPPORTS (PER ORIGINAL DRAWINGS). SE_- 0 2010 City of Tukwila BUILDING DIVISION Air System Design Load Summary for 1ST FLOOR Project Name: 105420 BELFOR Tenant Improvement Prepared by: Peterson Associates 09/09/2010 08:28AM FILE COPY REVIEWED FOR CODE COMPLIANCE Aro WINED SEP U 2010 City of Tukwila BUILDING DIVISI(1N 7I/L. -roN UNi RECEIV CITY OF TU LA SEP202ulti PERMIT CENTER Hourly Analysis Program v.4.4 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB / WB 89.5 °F / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU /hr) Latent (BTU /hr) Details Sensible (BTUIhr) Latent (BTU /hr) Window 8, Skylight Solar Loads 401 ft2 10922 - 401 ft2 - - Wall Transmission 454 ft2 339 - 454 ft2 884 - Roof Transmission 258 ft2 778 - 258 ft2 765 - Window Transmission 401 ft2 2782 - 401 ft2 11308 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 48 ft2 2366 - 48 ft2 1354 - Floor Transmission 2944 ft2 0 - 2944 ft2 1973 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 2944 W 10045 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 30 7350 6150 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 7000 0 - 0 0 Safety Factor 5% / 0% 2079 0 5% 814 0 >> Total Zone Loads - 43660 6150 - 17098 0 Zone Conditioning - 42873 6150 - 17836 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 2652 CFM 0 - 2652 CFM 0 - Ventilation Load 847 CFM 12000 - 6150 847 CFM 42175 0 Supply Fan Load 2652 CFM 0 - 2652 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 54873 0 - 80011 0 0 Central Cooling Coil - 54873 0 - 0 Central Heating Coil - 0 - - 60011 - » Total Conditioning - 54873 0 - 60011 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads FILE COPY REVIEWED FOR CODE COMPLIANCE Aro WINED SEP U 2010 City of Tukwila BUILDING DIVISI(1N 7I/L. -roN UNi RECEIV CITY OF TU LA SEP202ulti PERMIT CENTER Hourly Analysis Program v.4.4 Air System Design Load Summary for MEZZANINE Project Name: 105420 BELFOR Tenant Improvement Prepared by: Peterson Associates 09/09/2010 08:28AM 7/2. -Tu.) u# it /CODE FOR COMPLIANCE Ski.' i 2010 City of Tuktottila BUILDING nov,Sin1, Hourly Analysis Program v.4.4 Page 1 of 1 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1600 COOLING OA DB / WB 88.5 °F / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU /hr) Latent (BTU /hr) Details Sensible (BTU /hr) Latent (BTUIhr) Window & Skylight Solar Loads 520 ft2 25364 - 520 ft' - - Wall Transmission 574 ft2 467 - 574 ft' 1117 - Roof Transmission 2447 ft2 7461 - 2447 ft' 7251 - Window Transmission 370 ft' 2345 - 370 ft' 10434 - Skylight Transmission 150 ft2 932 - 150 ft' 4145 - Door Loads 0 W 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 Partitions 0 ft2 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 2447 W 8349 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 People 14 3430 2870 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 10000 0 - 0 0 Safety Factor 5% / 5% 2917 144 0% 0 0 » Total Zone Loads - 81285 3014 - 22948 0 Zone Conditioning - 59959 3014 - 24521 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Pienum Lighting Load 0% 0 - 0 0 - Return Fan Load 3453 CFM 0 - 3453 CFM 0 - Ventilation Load 297 CFM 3858 -3004 297 CFM 14848 0 Supply Fan Load 3453 CFM 0 - 3453 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 63817 10 - 39369 0 Central Cooling Coil - 63817 0 - 0 0 Central Heating Coil - 0 - - 39369 - » Total Conditioning - 63817 0 - 39369 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads 7/2. -Tu.) u# it /CODE FOR COMPLIANCE Ski.' i 2010 City of Tuktottila BUILDING nov,Sin1, Hourly Analysis Program v.4.4 Page 1 of 1 Air System Design Load Summary for WAREHOUSE Project Name: 105420 BELFOR Tenant Improvement Prepared by Peterson Associates 09/09/2010 08:29AM a,QOe t ot.,-r'Pv•r- t REVIEWED FOR CODE COMPLIANCE onvE SEP 0 City of Tukwila BUILDINT nninnM Hourly Analysis Program v.4.4 Page 1 of 1 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1400 COOLING OA DB / WB 89.5 °F / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU /hr) Latent (BTU /hr) Details Sensible (BTU /hr) Latent (BTU /hr) Window & Skylight Solar Loads 664 ft2 7514 - 664 ft2 - - Wall Transmission 2911 ft2 2345 - 2911 ft2 4461 - Roof Transmission 8515 ft2 29498 - 8515 ft2 19863 - Window Transmission 664 ft2 4434 - 664 ft2 14741 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 121 82 404 - 121 ft2 1343 - Ftoor Transmission 8515 ft2 0 - 8515 ft2 0 - Partitions' 0 ft2 0 - 0 ft2 0 - Geiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 3500 W 11942 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 0 W 0 - 0 0 - People 16 3920 3280 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 3003 0 5% 2020 0 » Total Zone Loads - 63060 3280 - 42429 0 Zone Conditioning - 56031 3280 - 41688 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 3520 CFM 0 - 3520 CFM 0 - Ventilation Load 426 CFM 5967 -3286 426 CFM 16618 0 Supply Fan Load 3520 CFM 0 - 3520 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 61998 -6 - 58306 0 Central Cooling Coil - 61998 0 - 0 0 Central Heating Coil - 0 - - 58306 - » Total Conditioning - 61998 0 - 58306 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads a,QOe t ot.,-r'Pv•r- t REVIEWED FOR CODE COMPLIANCE onvE SEP 0 City of Tukwila BUILDINT nninnM Hourly Analysis Program v.4.4 Page 1 of 1 C: Turn r I - Sigler Commercial HVAC 205 S. Puente Brea CA. 92821 ' '' � to the Experts. SUBMITTAL Contractor. Garry- Washington Engineer. Job Name: Date: 09/08/2010 Mark For 1 Qty 1 Model Number 1 Description CONTENTS • NOTE: NOTED" SUBMITTALS RELEASE OFFICES. REVISION: (2) 50TCQDO8A2A6-0AOA0 7.5 -Ton Pkg HP (2) 0734HJ7120A 0 -25% O/A PKG. (2) 0597HJ712CBCCRB11 11" KD ROOF CURB W/ CBC CONFORMING KIT (2) SIGLER -T1000 Commerical TStat OF SUBMITTAL: PRODUCT DESCRIPTION, PERFORMANCE DATA, DIMENSIONAL DATA, AND ACCESSORY DATA. ONE APPROVED COPY OF SUBMITTAL MUST BE RETURNED MARKED "APPROVED" OR °APPROVED AS FOR EQUIPMENT TO BE RELEASED FOR FABRICATION TO THE FACTORY. RETURNED REQUIRING ADDITIONAL, OR MODIFIED, DATA WILL BE RE- SUBMITTED BY CARRIER. FOR FABRICATION WILL COMMENCE WHEN AN "APPROVED" SUBMITTAL IS RETURNED TO OUR Original FILE COPY REVIEWED FOR CODE COMPLIANCE RECev = nVE® CITY of TULA SEP 3 0 2010 SEP 2 0 2010 City of Tukwila PERMIT CENTER BUILDING niVISION M to -►2s Project: Prepared By: Unit Report For 50TCQDO8A2A6 -0A0A0 Unit Parameters Unit Model: 50TCQD08A2A6-0A0A0 Unit Size: 08 (7.5 Tons) Volts- Phase - Hertz: 460 -3-60 Heating Type: Heat Pump Dud Cfg: Vertical Supply 1 Vertical Retum Heating Capacity: Two-Stage Cooling Refrigeration Coil Unit Configuration Medium Static Option Belt Drive Al/Cu - Al/Cu Electro-mechanical controls Standard Dimensions (ft. in.) & Weight (Ib.) "' Unit Length: r 4" Unit Width: 4' 0" Unit Height. 4' 1" Base Unit Weight: 885 lb — Weights and Dimensions are approximate. Weight does not Include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights. refer to appropriate product data catalog. Warranty Information First Year - Parts Only (Standard) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 1 50TCODO8A2AB -OA0A0 Rooftop Unit Base Unit Medium Static Option Belt Drive Al/Cu - Al/Cu Electro- mechanical controls Standard REV LINED FOR CODE COMPLIANCE an RAVE SciJU2010 City of Tukwila BUILDING DIVISION Packaged Rooftop Builder 1.19i Page 1 of 1 Project: Prepared By: Performance Summary For 50TCQD08A2A6 -0A0A0 Part Number:50TCQDO8A2A6 -0A0A0 ARl EER: IPLV: Base Unit Weight: Base Unit Dimensions Unit Length: Unit Width: Unit Height: Unit Voltage- Phase - Hertz: Air Discharge: Fan Drive Type: Actual Airflow Site Altitude: Cooling Performance Condenser Entering Air DB: Evaporator Entering Air DB: Evaporator Entering Air WB: Entering Air Enthalpy: Evaporator Leaving Air DB: Evaporator Leaving Air WB: Evaporator Leaving Air Enthalpy: Gross Cooling Capacity: Gross Sensible Capacity: Compressor Power Input: Coil Bypass Factor: Heating Performance Outdoor Ambient Temperature: Entering Air Indoor Coil DB: Leaving Air Indoor Coil DB: Total Heating Capacity: Integrated Heating Capacity: Heating Power Input: High Temperature COP: Low Temperature COP: Supply Fan Extemal Static Pressure: Fan RPM: Fan Power: NOTE: Electrical Data Minimum Voltage: Maximum Voltage: Compressor #1 RLA: Compressor #1 LRA: Compressor #2 RLA: Compressor #2 LRA Outdoor Fan Motor Qty: Outdoor Fan FLA (ea): Indoor Fan Motor Type: Indoor Fan Motor FLA Power Supply MCA Power Supply MOCP (Fuse or HACR): Min. Unit Disconnect FLA: 11.20 12.4 885 lb 88.1 in 59.5 in 49.4 in 460 -3-60 Vertical Belt 3000 CFM 0 ft 95.0 80.0 67.0 31.44 58.6 57.5 24.73 90.50 69.20 6.60 0.088 F F F BTU /Ib F F BTU /Ib MBH MBH kW 47.0 F 70.0 F 96.2 F 85.00 MBH 85.00 MBH 7.04 kW 3.3 2.3 0.50 inwg 649 0.86 BHP Standard Static Fan Option 414 506 6.1 41 6.1 41 2 0.8 MED 3.4 18.7 25 20 REVIEWED FOR CODE COMPLIANCE AP ffIVED SEP J U tiid City of Tukwila BUILDING nnnsinM Packaged Rooftop Builder 1.19i Page 1 of 4 WEIGHTS & DIMENSIONS (cont.) 91;0,1 100111 0001 OyMINS;DOSS11'K M0Il0C0EIg5OIMiKS(OK5 (44119 Cl (.8o 1* 1 gEtio OIRi('IGN Of 000 1.110 I4I4I .0011 11 1 311111 1781 11)00(41 f<C9091110 0.000 0'109011 10 100 151'1 1 90100. AIR 1 31 300 40 1119 MIS*' 9101 1 +0311 sum, IIT " -___ 1--- .. 39 sre 1511 0111510[ 1a 919 11101 4® TOP 1 1 3!111 IS 00/ 1091 1 91• 1 1 1 1 L 111A 911 :091111 901 9((111 00.01 O'13910�T 19(10)0 1/0101110 .,H[ 011x11.[(1 0 1 3'0 101 'RP ;1109 •10'11 .11311 rI/CNT 100000 000,1) .CC1SS 1.001 .9111 ' _.. 004 J 140100 �95Ny 011000 0010911.10 110 Y N Il14r ..•0 000000/109 Vertical Connections / Economizer Bach +15 I �.. 1, +11 - i imi I'U1 (090(90911 01110 :;310 3.1 L 1 101 •1111 I,, son s 110 1 9 sal L a 1/8 1 +011 -.- 4 Ira - -- •'551 1+0051 1 1 01 100 10511 Honzontal CionnectOns / Economizer 1 0 r 0 100. 0,11 DIJ 1:91,1 __S.... 0 119' ,711 010 IIND 3001101. 111101 U(. +000 1 1 311' 1 11.• 3003103/01 09910 ( 11 ' •011 011 P0000 SUPPI 0 190(0 MT "1111( 110w SI11S 1PE 1151 01. 11110 POYID SUM* MI 7 111' 1041 D(. P0019 S6PPL■ 090Ce0J• 1100 101 0811 10191 10010 0.0116 /1001010 100 010 <10r•P09001101 111019000 0090011 5110 9101 000 110 0 00(1 611(5 '901 1 ,13• .11 ]w 000' IA( 11 Ore• In )1 111. 10010 Pa01 10,9. 1111 .1 00 •1990 000 0010 011 1. 1000 08110, 1111.960 ID) alt 01 • AN PROYIM0 Fig. 5 - Dimensions 50TCQ 08 -09 21 0011 1 3 ,501[0008 1 ., 310 111111 isC9(0009 10 11 t"!' 8888 a 0 1- 0 1,: COD E COMP FOR ®(� COMPLIANCE SE ' a 2ti10 City of Tukwila BUILDING OIVLginI WEIGHTS & DIMENSIONS (cont.) i 51D UNI' CORNER i CORNER CORNER CORNER C G LNI W[]641 w:IGN' :AI WIGHT 191 WEIGHT IC) WEIGHT ID . IBS1 '(G. LBS KG. [85 KG [85 KG LBS : KG 0 r / - > • 50,r0008 1 885 1 401 187 99 i 198 7? 141 111 293 i 133 39 15/16 110141 35 114 (89911 23 1/2 [5911 50'COL',9 910 ! 413 200 91 1 166 , '5 /41 111 197 135 39 518 11006] 34 11? (8761) 23 'I? [591] 0 t- t- o A B C D Fig. 6 - Dimensions 50TCQ 08 -09 Fig. 7 - Service Clearance DIMENSION CONDITION 48" (1219 mm) 1 Unit disconnect is mounted on panel 18" (457 mm) No disconnect. convenience outlet option 18" (457 mm) Recommended service clearance 12' (305 mm) Minimum clearance 42' (1 067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall) 38" (914 mm) Surface behind servicer is electrically non - conductive (e.g., wood, fiberglass) Special Check for sources of flue products within 10 -ft of unit fresh air intake hood 38' (914 mm) Side condensate drain is used 18' (457 mm) Minimum clearance __._._ 42° (1087 mm) Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) 38' (914 mm) Surface behind servicer is electrically non - conductive (e.g., w C08878 COB337 CODE COMPLIANCE PP num SEP lJ \j L�;J City of Tukwila BUILDING DivISI(W C ONO A 6 1 50 ID SUBMITTAL 2 1 KD 597 SERIES 14" HAS (6) HO 11" HAS (A) Hours Er HAS UOLES DETAIL A SCALE 1 : 8 ATTACH (E)41041/2 ((0) 110612' FASTEN TO CORNER oRAC7CRT WITH 1/1".20 X Y1 LOCKNUTS AND BOLTS UNIT BASE RAIL 16 GA MICROHOLU TTA CU TO UNIT (4) et 041" TEK SCREWS (8".11") (5) 6(0.1' TEK SCREWS (14.) U. ?ULM/ITER WOOD NAILER GA CURB FRAME (5A in HOLODOWN 14 GA CURB FRAME (14") 1.000 DETAIL KITS FOR STANDARD CURB 0597CBC07KIT08 GOOD FOR 8" ONLY 0.597CBCO7KTT11 GOOD FOR II" ONLY PA^ MicroMet1 Corporation 81821111=21.8.121i 0597-A008-07CBC 8" TALL KD 597 SERIES 0597,40.11-07CBC II" TALL ASSEMBLED CURBS 0597-A014-07CBC 14" TALL ANCHORAGE DETAILS TO ROOF: •KNOCKED DOWN CONSTRUCTION 'GASKET PACKAGE INCLUDED 'PERIMETER )1000 NAILER 8' TO 14" L_ .000 STRUCFURALLY CALCULATED KNOCKED DOWN CURB FOR CARRIER 48/50 HJ,TM,TF 008-014, 5011K) 008-012 UNITS DAT& 01/2009 N. (800) 884-4662 $2.1EEI.ATTACN0t88,7';. (If u H.C11111610.• wariarnatyrimic., 1,2414Cati; INi800) 662-4671 SEE SIMEL ATTACHMENT DETAIL SHEETS. (6"MIN EDGE DISTANCE) SliTai r smusms SDS WAVASHER LoCk21(90) 2484800 SPACED. (e) EACH LONG SIDE. R ON CURB FLANGE. EvENLY (1.11 UTSIMPSON TOES 111) INENI.1 SPACEELCENTER ON CURD FLANGE r bury SPACING Ilan rp (1) ((ACM 18056 1(05 go EACH LONG SIDE, (31 EACH 181)06 5125 , MINORCO N TKO 011.60NNG 5)0111 BILE Ntaptenr oF eentrocert. ccoaponA no». ANT REssmouctuu D pArroa wiling RTTBOINTIDI worro. rowastaleN or footomEn. gomuunom. is mom:wren. ..C.... I I If I 1 DRAWN trorunee MEETS SEISMIC REoUIREMENTS 005 FOLLOWING CODE& 2007 CBC 2006 IBC 1 1 A 1118/H/ITA1 MicroMetl FORM NO.1899 -4P DATE: 11199 SUBMITTED TO COMPANY• DRAWN BY M.HARGIS JOB NAME' EQUIPMENT. NOTES' Filler panel for 10, 12 1/2 ton on 0734- HJ7 -120A Hood with Barometric Inlet Damper for Carrier 48/50 TJ,HJ, GJ 004 -014 units Part Number: 0734 Series FEATURES: Color coordinated, baked -on paint finish Insulated cover panel Attachment hardware package provided. Outside AIr Intake Hoods Spec.'s (in Inches) Carrier 48150 TJ, HJ, QJ Micro Metl Part No Deserl tlon P A g Ship wt. 004-007 0734- HJ3 -60A Manual 0A hood w/Barometric Damper 11 15/18 2 13!66, 121bs 008 -014 0734- HJ7 -120A Manual OA hood w/Barometnc Damper 13 5/B• •37 1i2 151b8. 2 piece panel on 0734-#1J7 -120A 0 T "1"Pr, cejg E 0 rn Hood with barometric inlet damper Screen section to be snipped -out when used in horizontal application Note: Hood is shipped unattached to cover panel. SPARKS /CA DOWNSHOT APPLICATION HORIZONTAL APPLICATION In the horizontal application, the hood and screen section must be secured over a field cut opening in the side of the field supplied return air duct. Return duct (field suppled THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETLCORP • 3418 ROOSEVELT AVENUE •INDIANAPOLtS,IN. 48218.1. 800-682- 4822•••MICROMETL WEST • 202SOUT 14t8THST.• SPARKS, NV89431.1. 800 - 884 -4682 Sigler T1000 Thermostat Large, Easy -To -Read Display — Screen size is more than double competitive thermostats in this class, allowing for more information to be displayed on the easy -to -view backlit display Multiple Lockout Levels Save energy and money by preventing unauthorized setting changes. Holiday Setback — ----• Lets users select the temperature to maintain while they're away from the building without re- programming. Menu -dnven programming makes it even easier. TR21:20K ohm sensor TR21 -A: 10K ohm sensor used for averaging only) Temperature Sensors — TR2 t Series wall modules cover all necessary control and averaging applications. making Honeywell your best sensor source. Utilizing both the TR2 1 and TR2' -A sensors, different averaging networks can be created to tit all your needs, Call toll -free 1- 800 - 637 -3163 i I 1� Saves Energy — Easy-to-use, merw-driven programming helps your customers save up to 33% off energy bills. Title 24 Energy /Air Quality Compliance — Preoccupancy Purge and Override Limits meet all fresh air and override limitation requirements, Qualities for utility rebates. Commercial Comfort — Commercial algorithm, configurable recovery ramps, and temporary override button allow users to control at setpoirlt and guarantee a comfortaibe environment. Temperature Averaging Networks 1 R 1,1111 t+'r 'EtF rtvttlt Thermostat two tar a IMMO weed in swim wen a to : 20%. Each 20K ham 25% weight. the 10K has 50% weight. Thermostat 11mo tar n+ some . 20K. Each nee 50 %wage Thermostat Four 20Kh in same parade ■ 20K. Eadn 2qK nes 25% waptn. REVIEWED FOR CODE COMPLIANCE 4PrionvEfl SEP 6 U 2010 City of Tukwila BUILDINGDIVISinM 1 1 PENT COORn COPVRl PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -125 DATE: 09/20/10 PROJECT NAME: BELFOR PROPERTY RESTORATION SITE ADDRESS: 4320 S 131 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: )uilding 'vision Public Works (1) AK Mg. Fire Prevention Structural Planning Division Permit Coordinator Li DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete if,4 Comments: Incomplete n DUE DATE: 09/21/10 Not Applicable Ei Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route It Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/19/10 Approved ❑ Approved with Conditions INI Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page or General /Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company THE G R A Z AK CORPORATION 6235355905 21639 N 14Th Ave Phoenix AZ 85027 Out Of State Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602966258 Active GRZKCGR912QQ Construction Contractor 12/14/2009 12/14/2011 General Unused Business Owner Information Name Role Effective Date Expiration Date BEER, GARY LENN President 11/16/2009 Amount BEER, RHONDA DAWN Vice President 11/16/2009 ACPGLA0720460938909/16/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 HARTFORD FIRE INS CO 59BSBFP0392 11/06/2009 Until Cancelled $12,000.00 11/16/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 AMCO INS CO ACPGLA0720460938909/16/2010 09/16/2011 $1,000,000.0009 /08/2010 1 NATIONWIDE MUTUAL INS CO ACP7251564364 09/16/2009 09/16/2010 $1,000,000.00 12/14/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount NRUS000432 11/24/2009 18.27.200(1)(a) RCW CONSTRUCTION INFRACTION Satisfied $500.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 10/05/2010 MECHANICAL LEGEND SINGLE I DOUBLE I ABBR. I DESCRIPTION J 0 RECTANGULAR DUCT (NEW) (NEW) r f 4. 7 f � o TRANSITION D Fr---a ° ROUND DUCT (NEW) (OR OVAL) 0 RD 23 OVAL C () jr--- -4 :: 11 ° RECTANGULAR DUCT (EXISTING) J. — e:::]3 ° ROUND DUCT (EXISTING) o 45 DEG. TAP: USE AT BRANCH DUCTS ONLY 'r -r ° DUCT SPLIT 14/DAMPER: USE AT ELBOWS AND TEES: PROPORTION DUCT AREAS BY GEM'S 4 L r 'r ^ Jr 0 CURVED ELBOW -MIN. RADIUS R: 15 WIDTH jr 4 0 40 DEG. ELBOW WITH SINGLE RADIUS TURNING VANES 4 `' 4/.. ° FLEXIBLE DUCT CONNECTION +-- 111111 --4 111111 !r VD VOLUME DAMPER W/L.OGKING QUADRANT r I o SPIN -IN FLEX PUGT TAKE -OFF YV/DAMPER .jr + i Jr + tt ---)_ SaQ SPLITTER DAMPER WITH LOCKING QUADRANT ) ° RI SA SUPPLY AIR 0 RI EXH EXHAUST AIR 0 171 RA RETURN AIR ° El REL RELIEF AIR 0 05A OUTSIDE AIR o 0 o NEW CONNECTION TO EXISTING 0 o TA TRANSFER AIR 0 0 ER EXHAUST REGISTER 0 o ED EXHAUST DUCT 0 o AFF ABOVE FINISHED FLOOR 0 o BFF BELOW FINISHED FLOOR 0 o NT5 NOT TO SCALE 0 o EH EXHAUST HOOD 0 0 T THERMOSTAT ®— F/5 COMBINATION FIRE/SMOKE DAMPER 50 SMOKE DUCT DETECTOR @ © O pF o FIRE STAT GET AT 165° 0 00 o OUTSIDE AIR STAT O O ° SENSOR OSA CALCULATION OFFICE: 3743 SF 7 PEOPLE /1000 SF = 26 PEOPLE @ 20 CFM EA = 520 CFM CONF. ROOM: 446 SF 50 PEOPLE /1000 SF = 22 PEOPLE @ 20 CFM EA = 440 CFM CORRID ❑RI 482 SF 482 SF @ 0.05 CFM /SF = 24 CFM RESTROOMSI 3 WATER CLOSETS @ 75 CFM EA = 225 CFM RECEPTION /WAITING: 140 SF 60 PEOPLE /1000 SF = 8 PEOPLE @ 15 CFM EA = 120 CFM 1329 CFM REQUIRED 1400 CFM PROVIDED REVISIONS No changes shad be made tot Vet scope of work without prior approval Tukwila Building Division. NOTE: Revisions will require plan rev nw fees submittal and may include additional FEL COPY Permit No. Plan review approval is subject to errors and omissions. authorize Approval of construction documents does o thc: violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By 7 © �O City Of Tukwila BUILDING DIVISION Date: CD_1 8 "0 175 CFM SEPARATE PERMIT REQUIRED FOR: ❑ Mebhanfoal Qflectdcat CiiPIumbIng Gioetas Piping City of Tukwila BUILDING DIVISION 10 "DIA EXH. FROM 1ST FLOOR (OFF –SET DUCT TO MAINTAIN 10' -0" FROM O.S.A INTAKE) 14 "0 CD -1 8 "0 175 CFM CD -1 8 "0 125 CFM (2 –WAY) 10 "DIA EXH. THRU ROOF TO ROOF CAP V4" CONDENSATE DOWN IN WALL CD_1 8 "0 150 CFM CD -1 8 "0 150 CFM MECHANICAL MEZZANINE FLOOR PLAN ire. -,.b. RG -1 14 "0 U/C DOOR 3/4 (TYPICAL) NEW DRIVE IN RAMP 1 5" DIA. FLUE UP THRU ROOF. (10' -0" A.F.F) CD -1 6 "0 100 CFM 10"DIA EXHAUST UP TO 2ND FLOOR 3/4" CONDENSATE TO LAVATORY TAILPIECE Ye CONDENSATE DOWN IN WALL FROM HP -1 AND HP -2 REVIEWED FOR CODE COMPLIANCE 3 1010 CtSEP �!ofTuU kwiIR BUILDING 1)11/ISIMI 24X18 SA FROM HP -1 24X20 RA FROM HP -1 CD_1 10 "0 275 CFM 20X12 U/C DOOR V4" CD_1 10 "0 CD 1 8 "O 200 CFM C.11-1. 8"o 125 CFM U/C DOOR V4" CD_1 10 "0 350 CFM RECEIV CITY of TUKMLA PERMIT CENTER A N 1R W/10 "0 SFER DUCT IGAI— 3 CD -1 10 "0 400 CFM CD -1 10 "0 400 CFM MECHANICAL FIRST FLOOR PLAN CD_1 1o"� 350 CFM 7201 IL Dle ny Drow Drive WOW Rad4Mizono8WM 0 )943.m16 PETERSON ASSOCIATES Fac.n,e�9432507 MCI CONSULTING ENGINEERS INC. ,bb No, 105420 ALL CONCEPTS, DESIGNS, AND DATA INDICATED ON THESE DOCUMENTS ARE THE SOLE PROPERTY OF THE PETERSON ASSOC. ENGINEERS, INC. AND SHALL NOT BE USED FOR ANY OTHER PURPOSE THAN ORIGINALLY INTENDED WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER. N o) 0) CD O) in 00 00 1 I co d- d' N 0 0 w z oa 17/c7c) L,J8 seas ao v W 0 I, z a H Z r/9 � H 0 rn 6-4 1 CrJi� C—♦ M1 1. PROVIDE WITH 1" FACTORY FILTER RACK AND 1" PLEATED 'FARR' 30/30 TYPE FILTERS. 2. PROVIDE WITH FACTORY 25% OUTSIDE AIR HOOD. 3. PROVIDE WITH 7 DAY PROGRAMMABLE THERMOSTAT AND SUB -BASE AND LOCKING COVERS. 4. PROVIDE FACTORY ROOF CURB. 5. A 120V DUCT SMOKE DETECTOR SHALL BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR. 120V WIRING SHALL BE BY ELECTRICAL CONTRACTOR. LOW VOLTAGE INTERLOCK (SHUTDOWN) WIRING TO HVAC UNIT SHALL BE BY MECHANICAL CONTRACTOR. PROVIDE AND INSTALL CEIUNG MOUNTED STATUS LED. 6. PROVIDE BELT DRIVE WITH ADJUSTABLE SHEAVES. HEAT PUMP UNIT SCHEDULE e PACKAGED MODEL# MARK MANUF./ MODEL # AIR CAPACITIES HP EER/ SEER (B1U/VIMR) CYCLE HEALING /COOUNG CAPACITIES ELECTRICAL DATA OPER. REMARKS TOTAL CFM OA CFM ESP IWG BLOWER HP SMOKE DETECTOR ENT AIR AMBIENT B1UH DB WB DB WB TOTAL SENSIBLE MCA MOCP VOLT /0' 1 CARRIER 50TCQD08 3000 850 .5 1.5 YES 11.2 COOL 80 67 95 - 85.1 67.0 18 7 25 460/3 780 000000 HEAT 70 - 30 - 69.3 - 2 CARRIER 50TCQD08 3000 550 .5 1.5 YES 11.2 COOL 80 67 95 - 85.1 67.0 18 7 25 460/3 780 OOOOOO HEAT 70 - 30 - 69.3 - 1. PROVIDE WITH 1" FACTORY FILTER RACK AND 1" PLEATED 'FARR' 30/30 TYPE FILTERS. 2. PROVIDE WITH FACTORY 25% OUTSIDE AIR HOOD. 3. PROVIDE WITH 7 DAY PROGRAMMABLE THERMOSTAT AND SUB -BASE AND LOCKING COVERS. 4. PROVIDE FACTORY ROOF CURB. 5. A 120V DUCT SMOKE DETECTOR SHALL BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR. 120V WIRING SHALL BE BY ELECTRICAL CONTRACTOR. LOW VOLTAGE INTERLOCK (SHUTDOWN) WIRING TO HVAC UNIT SHALL BE BY MECHANICAL CONTRACTOR. PROVIDE AND INSTALL CEIUNG MOUNTED STATUS LED. 6. PROVIDE BELT DRIVE WITH ADJUSTABLE SHEAVES. 1. SWITCH WITH UGHT. 2. PROVIDED BY OTHERS. MECHANICAL NOTES 1. FURNISH ALL LABOR, MATERIALS, TOOLS EQUIPMENT, FEES, PERMITS, CERTIFICATE OF INSPECTION, ETC., NECESSARY OR REASONABLE, REQUIRED FOR THE COMPLETE INSTALLATION OF ALL AIR CONDITIONING WORK. THE WORK SHALL BE IN STRICT ACCORDANCE WITH ASHRAE GUIDE, AND ALL LOCAL AND STATE CODES, ORDINANCES AND REGULATIONS. 2. DUCTS SHALL BE FABRICATED OF PRIME GALVANIZED LOCK FORMING QUAUTY STEEL SHEETS, OR A GAUGE IN ACCORDANCE WITH THE FOLLOWING TABLE: •DUCTS WITH LONGEST SIDE NOT MORE THAN 12" IN WIDTH-26 GA •DUCTS WITH LONGEST SIDE 13" TO 30" IN WIDTH 24 GA •DUCTS WITH LONGEST SIDE 31" TO 40" IN WIDTH 22 GA • DUCTS WITH LONGEST SIDE OVER 40" 20 GA 3. PROVIDE RADIUS ELBOWS, TURNING VANES, AND SPUTTER DAMPERS IN BRANCHES AND EXTRACTORS WHERE APPUCABLE. 4. DUCT SIZES SHOWN ARE "CLEAR INSIDE" DIMENSIONS. 5. EQUIVALENT SIZED ROUND DUCT MAY BE USED IN LIEU OF RECTANGULAR DUCT. 6. TEST AND BALANCE SYSTEM. SUBMIT CERTIFIED AIR BALANCE REPORT INCLUDING OUTSIDE AIR TO ARCH. 10 DAYS PRIOR TO C OF 0. PROVIDE COPY TO CITY INSPECTOR. 7. ALL DUCTWORK TO BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH " ASHRAE GUIDE AND SMACNA OR IMC (2006) STANDARDS ". SEAL ALL DUCTWORK, LONGITUDINAL AND LATITUDINAL JOINTS WITH DP -1010 SEALANT (PER 2006 IECC). 8. EXACT PLACEMENT OF DIFFUSERS AND REGISTERS TO BE COORDINATED WITH ARCHITECTURAL - REFLECTED CEILING PLAN. 9. CONTRACTOR TO VERIFY LOCATION OF ALL AIR EQUIPMENT SO THAT NO INTERFERENCE ARE ENCOUNTERED WITH OTHER EQUIPMENT OR WITH STRUCTURAL ELEMENTS. 10. CONTRACTOR MAY SUBSTITUTE "APPROVED EQUAL" FOR ALL HVAC EQUIPMENT. 11. MECHANICAL CONTRACTOR TO VERIFY THAT ALL DUCTWORK WILL FIT WHERE INDICATED WITHOUT INTERFERENCE. 12. CONTRACTOR AND ARCHITECT TO VERIFY T -STAT LOCATIONS. 13. THERMOSTATS MUST BE LOCATED 48" ABOVE FINISHED FLOOR. (TO CENTERLINE OF THERMOSTAT) T -STATS SHALL BE 7 DAY PROGRAMMABLE WITH SET -BACK CAPABILITIES (PER 2006 IECC). 14. MECHANICAL CONTRACTOR SHALL INSULATE ALL NEW SUPPLY AND RETURN AIR DUCTWORK LOCATED WITHIN AN ATTIC SPACE WITH MIN. R -5 INSULATION, ALL NEW SUPPLY AIR DUCTWORK LOCATED WITHIN A PLENUM SPACE WITH MIN. R -5 INSULATION AND /OR ANY DUCTWORK EXPOSED TO THE EXTERIOR WITH MIN. R -8 INSULATION (PER 2006 IECC). INSULATION NOT REQUIRED FOR EXHAUST DUCT. 15. HVAC CONTRACTOR SHALL REPLACE ALL FILTERS UPON COMPLETION OF CONSTRUCTION. THIS INCLUDES FILTERS AT ALL NEW UNITS AND FILTERS AT ALL EXISTING UNITS EFFECTED BY CONSTRUCTION. MECHANICAL COMPLIANCE NOTES: HVAC SYS1FJd(S) 1. MECHANICAL SYSTEMS SHALL COMPLY WITH THE CURRENT EDITION OF THE WASHINGTON STATE ENERGY CODE AND THE 2009 INTERNATIONAL MECHANICAL CODE. 2. ALL HEAT PUMPS WITH SUPPLEMENTAL STRIP HEATERS MUST UTILIZE HEAT PUMP THERMOSTAT TO PREVENT STRIP HEATERS FROM ENERGIZING IF HEAT PUMP CAN ACCOMODATE THE LOAD. GENERAL REQUIREMENTS 1. ALL THERMOSTATS PROVIDED MUST BE FULLY PROGRAMMABLE WITH SETBCAK OPERATIONS. 2. ALL EXHAUST SYSTEMS SHALL HAVE BAROMETRIC DAMPERS TO CLOSE WHEN NOT IN OPERATION. 3. OSA SYSTEM DESIGNED TO COMPLY WITH MINIMUM OSA REQUIREMENTS P.,ER CHAPTER 4 OF THE 2009 IMC. 4. INSUALTE ALL SUPPLY AND RETURN DUCTS LOCATED WITHIN ATTIC SPACE WITH MINIMUM R -5 INSULATION, ALL SUPPLY DUCTS LOCATED WITHIN PLENUM SPACE WITH MINIMUM R -5 INSULATION AND /OR ANY DUCTWORK EXPOSED TO EXTERIOR TO BE INSULATED WITH MINMUM R -8 INSULATION. EXHAUST DUCTS DO NOT REQUIRE ANY INSULATION. 5. ALL JOINTS SEAMS AND CONNECTIONS IN DUCTWORK SYSTEM TO BE SECURELY SEALED USING WELDMENTS, MECHANICAL FASTENERS WITH SEALS, GASKETS, MA11CS OR TAPES. TAPES AND MASTICS MUST BE UL 181(A) OR (B) LISTED. 6. MECHANICAL FASTENERS AND SEALS, MASTICS OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS OF OTHER AIR DISTRIBUTION EQUIPMENT. 7. OPERATION AND MAINTENANCE DOCUMENTATION TO BE PROVIDED TO OWNER AT COMPLETION OF PROJECT. 8. EACH SUPPLY AIR OUTLET, DAMPER SHALL HAVE ITS OWN BALANCING DEVICE. GRILLE, REGISTER & DIFFUSER SCHEDULE EXHAUST FAN SCHEDULE 9 MARK MODEL# TYPE CFM E.S.P. HP VOLT 0 B.D.D. DRIVE DER' REMARKS I, 2, 3 QNUTONIID GL6. 100 0.25 FRAGT. 120/1 YES DIRECT 20 CIO TIERED WHITE STEEL OBD 30 W /AIRSCOOP AND VOLUME DAMPER RG -1 PRICE 535 RETURN GRILLE LAY -IN OO 1. SWITCH WITH UGHT. 2. PROVIDED BY OTHERS. MECHANICAL NOTES 1. FURNISH ALL LABOR, MATERIALS, TOOLS EQUIPMENT, FEES, PERMITS, CERTIFICATE OF INSPECTION, ETC., NECESSARY OR REASONABLE, REQUIRED FOR THE COMPLETE INSTALLATION OF ALL AIR CONDITIONING WORK. THE WORK SHALL BE IN STRICT ACCORDANCE WITH ASHRAE GUIDE, AND ALL LOCAL AND STATE CODES, ORDINANCES AND REGULATIONS. 2. DUCTS SHALL BE FABRICATED OF PRIME GALVANIZED LOCK FORMING QUAUTY STEEL SHEETS, OR A GAUGE IN ACCORDANCE WITH THE FOLLOWING TABLE: •DUCTS WITH LONGEST SIDE NOT MORE THAN 12" IN WIDTH-26 GA •DUCTS WITH LONGEST SIDE 13" TO 30" IN WIDTH 24 GA •DUCTS WITH LONGEST SIDE 31" TO 40" IN WIDTH 22 GA • DUCTS WITH LONGEST SIDE OVER 40" 20 GA 3. PROVIDE RADIUS ELBOWS, TURNING VANES, AND SPUTTER DAMPERS IN BRANCHES AND EXTRACTORS WHERE APPUCABLE. 4. DUCT SIZES SHOWN ARE "CLEAR INSIDE" DIMENSIONS. 5. EQUIVALENT SIZED ROUND DUCT MAY BE USED IN LIEU OF RECTANGULAR DUCT. 6. TEST AND BALANCE SYSTEM. SUBMIT CERTIFIED AIR BALANCE REPORT INCLUDING OUTSIDE AIR TO ARCH. 10 DAYS PRIOR TO C OF 0. PROVIDE COPY TO CITY INSPECTOR. 7. ALL DUCTWORK TO BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH " ASHRAE GUIDE AND SMACNA OR IMC (2006) STANDARDS ". SEAL ALL DUCTWORK, LONGITUDINAL AND LATITUDINAL JOINTS WITH DP -1010 SEALANT (PER 2006 IECC). 8. EXACT PLACEMENT OF DIFFUSERS AND REGISTERS TO BE COORDINATED WITH ARCHITECTURAL - REFLECTED CEILING PLAN. 9. CONTRACTOR TO VERIFY LOCATION OF ALL AIR EQUIPMENT SO THAT NO INTERFERENCE ARE ENCOUNTERED WITH OTHER EQUIPMENT OR WITH STRUCTURAL ELEMENTS. 10. CONTRACTOR MAY SUBSTITUTE "APPROVED EQUAL" FOR ALL HVAC EQUIPMENT. 11. MECHANICAL CONTRACTOR TO VERIFY THAT ALL DUCTWORK WILL FIT WHERE INDICATED WITHOUT INTERFERENCE. 12. CONTRACTOR AND ARCHITECT TO VERIFY T -STAT LOCATIONS. 13. THERMOSTATS MUST BE LOCATED 48" ABOVE FINISHED FLOOR. (TO CENTERLINE OF THERMOSTAT) T -STATS SHALL BE 7 DAY PROGRAMMABLE WITH SET -BACK CAPABILITIES (PER 2006 IECC). 14. MECHANICAL CONTRACTOR SHALL INSULATE ALL NEW SUPPLY AND RETURN AIR DUCTWORK LOCATED WITHIN AN ATTIC SPACE WITH MIN. R -5 INSULATION, ALL NEW SUPPLY AIR DUCTWORK LOCATED WITHIN A PLENUM SPACE WITH MIN. R -5 INSULATION AND /OR ANY DUCTWORK EXPOSED TO THE EXTERIOR WITH MIN. R -8 INSULATION (PER 2006 IECC). INSULATION NOT REQUIRED FOR EXHAUST DUCT. 15. HVAC CONTRACTOR SHALL REPLACE ALL FILTERS UPON COMPLETION OF CONSTRUCTION. THIS INCLUDES FILTERS AT ALL NEW UNITS AND FILTERS AT ALL EXISTING UNITS EFFECTED BY CONSTRUCTION. MECHANICAL COMPLIANCE NOTES: HVAC SYS1FJd(S) 1. MECHANICAL SYSTEMS SHALL COMPLY WITH THE CURRENT EDITION OF THE WASHINGTON STATE ENERGY CODE AND THE 2009 INTERNATIONAL MECHANICAL CODE. 2. ALL HEAT PUMPS WITH SUPPLEMENTAL STRIP HEATERS MUST UTILIZE HEAT PUMP THERMOSTAT TO PREVENT STRIP HEATERS FROM ENERGIZING IF HEAT PUMP CAN ACCOMODATE THE LOAD. GENERAL REQUIREMENTS 1. ALL THERMOSTATS PROVIDED MUST BE FULLY PROGRAMMABLE WITH SETBCAK OPERATIONS. 2. ALL EXHAUST SYSTEMS SHALL HAVE BAROMETRIC DAMPERS TO CLOSE WHEN NOT IN OPERATION. 3. OSA SYSTEM DESIGNED TO COMPLY WITH MINIMUM OSA REQUIREMENTS P.,ER CHAPTER 4 OF THE 2009 IMC. 4. INSUALTE ALL SUPPLY AND RETURN DUCTS LOCATED WITHIN ATTIC SPACE WITH MINIMUM R -5 INSULATION, ALL SUPPLY DUCTS LOCATED WITHIN PLENUM SPACE WITH MINIMUM R -5 INSULATION AND /OR ANY DUCTWORK EXPOSED TO EXTERIOR TO BE INSULATED WITH MINMUM R -8 INSULATION. EXHAUST DUCTS DO NOT REQUIRE ANY INSULATION. 5. ALL JOINTS SEAMS AND CONNECTIONS IN DUCTWORK SYSTEM TO BE SECURELY SEALED USING WELDMENTS, MECHANICAL FASTENERS WITH SEALS, GASKETS, MA11CS OR TAPES. TAPES AND MASTICS MUST BE UL 181(A) OR (B) LISTED. 6. MECHANICAL FASTENERS AND SEALS, MASTICS OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS OF OTHER AIR DISTRIBUTION EQUIPMENT. 7. OPERATION AND MAINTENANCE DOCUMENTATION TO BE PROVIDED TO OWNER AT COMPLETION OF PROJECT. 8. EACH SUPPLY AIR OUTLET, DAMPER SHALL HAVE ITS OWN BALANCING DEVICE. GRILLE, REGISTER & DIFFUSER SCHEDULE MARK MANUF./ MODEL # DESCRIPTION FRAME STYLE FINISH MATERIAL DAMPER MAX. REMARKS CD -1 PRICE SCD CEILING DIFFUSER LAY -IN TIERED WHITE STEEL - 30 1O CD -2 gCD CEILING DIFFUSER SURF. TIERED WHITE STEEL OBD 30 W /AIRSCOOP AND VOLUME DAMPER RG -1 PRICE 535 RETURN GRILLE LAY -IN LOUVER WHITE STEEL - 30 24X24 LAY -IN WITH SQUARE TO ROUND ADAPTER (SIZED PER PLAN) EG -1 PRICE 80 EXHAUST GRILLE SURF. EGG CRATE WHITE STEEL OBD 30 Li "XLi "X1�i" CORE SIZE PER PLAN 1. COORDINATE T -BAR GRID FRAMING PRIOR TO ORDERING DEVICE. °v GAS UNIT HEATER SCHEDULE WEATHERPROOF SEAUNG STRIP PREFABRICATED CURB - BY UNIT MANUFACTURER (MODIFY AS REQUIRED BY ROOFING SUPPLIER) -WOOD CURB INSERT MARK MANUF./ MODEL # CFM ESP MOTOR FUEL GAS, BTUH REMARKS HP VOLT /0 INPUT OUTPUT I B 1200 - I/3 120/1 6A5 '75p00 60p00 PROVIDE THERMOSTAT SCREW CURB FLANGE W/12" X 2" GALV. SCREWS 0 12" O.C. W /AIRSCOOP AND VOLUME DAMPER 1 1 • OR EQUAL A/C EQUIPMENT 16 GA. METAL STRAPS 24 GA. METAL COUNTER FLASHING 3" x 3" CANT STRIP I WEATHERPROOF SEAUNG STRIP PREFABRICATED CURB - BY UNIT MANUFACTURER (MODIFY AS REQUIRED BY ROOFING SUPPLIER) -WOOD CURB INSERT SUPPLY DUCTWORK AIRFLOW ' 'FLEXMASTERWEST' SPIN -IN FITTING . VOLUME DAMPER ROOFING SCREW CURB FLANGE W/12" X 2" GALV. SCREWS 0 12" O.C. W /AIRSCOOP AND VOLUME DAMPER 1 1 . i ROOF CONSTRUCTION TAPERED WOOD SHIM (PRESSURE TREATED LUMBER) TO MATCH PITCH - SCREWED TO ROOF DECK, DOWN INTO ROOF TRUSSES OR 2" X 4" BLOCKING BETWEEN TRUSSES. FLEXIBLE DUCTWORK TO SUPPLY OUTLET MAX. 12' -0" 0 NC MOUNTING DETAIL NTS © BRANCH DUCT TAKE -OFF DETAIL M1012S -- RE\flEWWED FOR CODE COMPLIANCE SL) Li J City of Tukwila BUILDING fIVISilri RE EN cir� ro TU u` SEP 2 0 2010 PERMIT CENTER 7201 N. Dram DMII Orin Suite 200 Phoenbc, kinono 85020 (602) 943.4116 F ile (602943.2507 PETERSON ASSOCIATES m Com CONSULTING ENGINEERS INC. Job No. 105420 ALL CONCEPTS, DESIGNS, AND DATA INDICATED ON THESE DOCUMENTS ARE THE SOLE PROPERTY OF THE PETERSON ASSOC. ENGINEERS, INC. AND SHALL NOT BE USED FOR ANY OTHER PURPOSE THAN ORIGINALLY INTENDED WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER. SYM DATE DESCRIPTION PROJECT 0441 0441 r .4 04- -05 -I0 SUBMIT FOR PERMIT -e" '" ` DRAWN BY t ' ' t;'" E . . WA' 06 -16 -I0 ii : I _► 1�►._. MJP `s. DATE i 44 - g $: -A_ - - CHECKED BY o MJP cc. `;a -.*°b , , i 4 DATE C * "4 -`` 04 -05 -10 x °�� ........ . N O) rnV) 00 CO 1 1 vi- d- N (0 (0 0 0 N N w Ox ma_ LI_ • 110C-0 U W 0 tea g d M2