Permit M10-128 - MUSEUM OF FLIGHT #9-04
MUSEUM OF FLIGHT #9-04 9305 EAST MARGINAL WY S M10 -128 City ofki'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 5624201034 Address: 9305 EAST MARGINAL WY S TUKW Project Name: MUSEUM OF FLIGHT #9 -04 Permit Number: M10 -128 Issue Date: 02/08/2011 Permit Expires On: 08/07/2011 Owner: Name: KING CO MUSEUM OF FLIGHT Address: 9404 E MARGINAL WAY S , SEATTLE WA 98108 Contact Person: Name: MICHAEL HARSHMAN Address: 11611 49 PL W , MUKILTEO WA 98275 Email: MARSHMAN@UMCI.COM Contractor: Name: UNIV MECHANCL CONTRS INC Address: 11611 49TH PL W , MUKILTEO WA 98275 -4255 Contractor License No: UNIVMC *343N9 Phone: 206 368 -6971 Phone: 206 - 364 -9900 Expiration Date: 10/03/2012 DESCRIPTION OF WORK: INSTALLATION OF TOILET EXHAUST FAN SYSTEM, ELECTRICAL ROOM EXHAUST FAN, REWORK EXISTING TOILET EXHAUST SYSTEM TO REDUCE AIR FLOW. Value of Mechanical: $33,860.00 Type of Fire Protection: SPRINKLERS /AFA Permit Center Authorized Signature: Fees Collected: $600.06 International Mechanical Code Edition: 2009 Date: V / 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: ✓ Print Name: FZ-c\ U.S G Date: 'if /1( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -128 Printed: 02 -08 -2011 • • PERMIT CONDITIONS Permit No. M10-128 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M10 -128 Printed: 02 -08 -2011 .. CITY OF TUKW,t Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Mechanical P Project No. • • ermtl use only% MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** ST1 E LOCA 1 th Site Address: 14- Ei s-r grq(rrti I WRY Tenant Name: /l16, sec4kri a 7' • Fir84).- Property Owners Name: lieu set t m of F/; f King Co Assessor's Tax No.: 1/-'T% P9--A Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No 98k0� Zip Mailing Address: q y 011 Ea s+ Ma rq l,1 J W i4rY 5. Name: m i c h G, vi Y3 el vhA •■ Mailing Address: Il (0 /I v19± Pi, W, E -Mail Address: m ars *t4 et puwvai: con SPkI -e City State r4- Day Telephone: 20(a- 36S -Cn97/ 0 4 u k, Jeo (,u 1 9 `1 K2 7 s City State Zip Fax Number: 20(o - 3 Co 5 -- 15g 0 A CONTRACTOR, INFORMATION Company Name: Mailing Address: Contact Person: Ur ver3; y-y Mee- 14Y,, 14 I Co4frtc fD.-s z e . whA k,1 le a City Day Telephone: 11 (0I I 21`14"1" PL U, Mtc),,ael l-i-ars► ill. e -.. E -Mail Address: ,'41 a rc, sln q vt 0 i4 rr. c.i, . r D Contractor Registration Number: Company Name: Mailing Address: Contact Person: SEL6 4rc1,1-1rtrt Par-Avers fp t% (i(nroe, 54 9$27 S State Zip 20(s) - 3026 - -(4 7 Fax Number: Z O ( o —3 (6 - I s c Expiration Date: M +bah /4°55. e h E -Mail Address: Pi.e SS »ier-@ 5rq par1-rife iip.Co/y.- Se4 City Day Telephone: Fax Number: Wf} `(q6(0 State Zip 20(— c73 --1(0q5 Ng, 1T1EER OF RECO] alts rust be stamped-by engineer of reca Company Name: Mailing Address: Contact Person: (In,vers� 11(0) UYR* PL.. W. A(hah 4/ Cvv4Y -AC"on ZIC. Doi-V1D Ina /on .e E -Mail Address: OYrtr Jon.e @ C4 CI, con-"— H:\Applications\Forms- Applications On Line\2010 Applications \7-2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh City State Zip Day Telephone: Fax Number: Z06_3coY -1Ra0 Page 1 of 2 401 istrm 6La& • Valuation of project (contractor's bid price): $ 33) (RoO Scope of work (please provide detailed information): 7;1.4°4 EXL, 5751en.. P,eC. OCm Fxti4l45 - c+I� Re work exi&-A)--;if To SySkeki- . r ec& r, > , Use: Residential: New ❑ Replacement ❑ Commercial: New )icrFuel Type: Electric Indicate type of mechanical work being installed and the quantity below: Gas Replacement Other: Unit Type: Qty Unit Type: , , Qty. Unit Type: yp Qty, Qty furnace <100k btu air handling unit >10,000 cfin fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser I 0 3-15 hp /500,000 btu floor furnace to connected to single duct I thermostat ( 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system I wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50 +hp/1,750,000 btu repair or addition to P heat/refrig/cooling system • Incinerator — domestic other mechanical equipment air handling unit <10,000 cfin incinerator — comm/ind . PERMIT APPLICATION NOTES- -_ Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHO ZED AGENT: Signature: Print Name: / 1 -h .e/ 3/473/m4 " Mailing Address: 11(08/ `if IA- Date Application Accepted: 001 121 I I'V Date: ,SecS 9 2o/ Day Telephone: 2 060 3 6 e.- &57/ /j 4 k1 /24'0 wit 9S2 7r City State Zip Date Application Expires: 0 21 I I I I Staff Initials: HAApplications\Forms- Applications On Line \2010 Applications 7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 2 of 2 901( /3WG. Ci, of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 20 6- 431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R10 -01872 Initials: JEM Payment Date: 09/21/2010 User ID: 1165 Total Payment: 1,551.23 Payee: LESTER W BOUCK SET ID: S000001422 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount M10 -127 M10 -128 PG10 -131 PG10 -132 TOTAL: 624.71 729.11 49.88 147.53 624.71 TRANSACTION LIST: Type Method Description Amount Payment Credit C MC 1,551.23 TOTAL: 1,551.23 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,551.23 TOTAL: 1,551.23 INSPECTION RECQRD Retain i. cry with- perr» t NSPECT ON'No: "..: . -,•r _,•4,xa• 4i.A.f• .••eYON.,,:.:..+L:=1 ;:aaiP41114I34(.i�' CITY OF TUKWILA BUILDING DIVISION. • ft:-• • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: imAkctruAn O c= c ‘ i„,vo Type otlnspection: �. ; Al A L / e . Address: 13 0 5 0_ _ A.lVeo-°A/4(...._ Date Called: Special Instructions: Date Wanted: l. • •.---i_ n✓ i f " p.m. Requester: . Phone No: C 1 i.— 333-T777/ • %Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ;C> r nr. s4 Z k4. 1/A1 4 AAAA- ;r, Date: PECTION FEE REQ IRED. Prig to next inspection.- fee must;Kbe' at 6300 Southcenter lvd.. Suite 100. Call to schedute,rlinspectiopi, • -•- . -- • "INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /'1(o-IV' o�� Project: l"�J1-e vm �'i -Di Type of Inspection: Rou(.� h / l4 Pc Address- .0 , AA 6. X/1tteCalled: Special Instructions: Date Wanted: --- a.m.. -2-t( p.m. Requester: Phone -57I _3337 . I f f pproved per applicable codes. ElCorrections required prior to approval. . COMMENTS: Date:.... L 9 INSPECTION FEE RE id at 6300 Southcenter IRED. Prior to lvd.. Suite 100. ext inspection. fee must be Call to schedule reinspection. C Department of Community Development Jack Pace, Director • City of Tukwila • Jim Haggerton, Mayor 02 -01 -2011 MICHAEL HARSHMAN 1161149PLW MUKILTEO WA 98275 RE: Permit Application No. M10 -128 9305 EAST MARGINAL WY S TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 09/21/2010, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 03/20/2011. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, CIA Bill Rambo Permit Technician File: Permit File No. M10 -128 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 z MEMORANDUM TO: Laurie Anderson FROM: Brenda Holt DATE: 10/13/2010 SUBJECT: Museum of Flight #9 -04 Permit Number M10 -128 Please draw a check in the amount of $129.05 (one hundred twenty -nine dollars and five cents) to be payable to Lester Bouck at University Mechanical Contractors Inc, 11611 49 PI W, Mukilteo WA 98275. The fees were incorrectly calculated for this permit which resulted in an overpayment of both the plan check and permit fees. Please forward the check to me and I will forward it on to the applicant. Thank you! 1 2 'T COD COPS ai PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -128 PROJECT NAME: MUSEUM OF FLIGHT #9 -04 DATE: 09/21/10 SITE ADDRESS: 9305 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: til —f 0 1 10k ° ®3�4� BfSiTtiing Division ire Prevention Public Works ❑ Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 14 Comments: Incomplete ❑ DUE DATE: 09/23/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 10/21/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr ter Friendly Page 6 General /Specialty Contractor A business registered as a construction contractor with LF&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name UNIV MECHANCL CONTRS INC UBI No. 578025176 Phone 2063649900 Status Active Address 11611 49Th Pl W License No. UNIVMC *343N9 Suite /Apt. License Type Construction Contractor City Mukilteo Effective Date 8/29/1966 State WA Expiration Date 10/3/2012 Zip 982754255 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ed Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status GRANSML982R3 GRANSTON MECHANICAL LLC Construction Contractor General Unused 12/23/2002 1/8/2009 Expired Business Owner Information Name Role Effective Date Expiration Date BUSH, GERALD D President 03/13/2002 Bond Amount GRANSTON, EDWARD B Secretary 03/13/2002 08965196 PETTERSON, DEAN M Treasurer 03/13/2002 SMITH, DOUG Vice President 03/18/2002 TRAVELERS CAS Et SURETY CO KOMMERS, EDWARD D Vice President 03/13/2002 09/13/2004 BALDWIN, TERRY L Vice President 03/13/2002 09/10/2003 GRANSTON, FRANK Treasurer 03/18/2002 12/23/2002 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 FIDELITY 8 DEPOSIT CO OF MD 08965196 07/31/2009 Until Cancelled $12,000.0006/04 /2009 6 TRAVELERS CAS Et SURETY CO 103335164 07/22/2001 Until Cancelled 07/31/2009 $12,000.00 10/03/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 30 THE PHOENIX INS CO C0526D8270PHX10 10/01/2010 10/01/2011 $1,000,000.0009 /22/2010 29 PHOENIX INS CO C0526D8270PHX09 10/01/2009 10/01/2010 $1,000,000.00 09/22/2009 28 TRAVELERS PROPERTY CAS INS CO DTE0526D8270TIL07 10/01/2007 10/01/2009 $1,000,000.0009 /19/2008 27 TRAVELERS PROPERTY CAS INS CO DTEC0526D8270TIK07 10/01/2007 10/01/2008 $250,000.00 09/21/2007 26 TRAVELERS INDEMNITY CO DTC0526D82701ND05 10/01/2006 10/01/2007 $1,000,000.00 09/19/2006 25 ST PAUL FIRE MARINE INS CO KC08400101 10/01/2004 10/01/2006 $1,000,000.00 09/21/2005 https://fortress.wa.gov/lni/bbip/Print.aspx 02/08/2011 DUCT LINE EQUIVALENTS LEGEND SINGLE LINE 0 0 ` 0I 0I 0 C I I 2 2 2 ■ 2 2 RECT ROUND ROUND ROUND 1 2 DOUBLE LINE v (fig") I -[11=1 691 iLDEt 2 2 R, 2 1 2 1 2 2 T MOD BDO 2 DESCRIPTION 90' ELBOW UP (SUPPLY) 90' ELBOW UP (RETURN /EXHAUST) 90' ELBOW DOWN (SUPPLY) 90' ELBOW DOWN (RETURN /EXHAUST) RADIUS ELBOW UP (SUPPLY) RADIUS ELBOW UP (RETURN /EXHAUST) RADIUS ELBOW DOWN (SUPPLY) RADIUS ELBOW DOWN (RETURN /EXHAUST) ROUND DUCT UP (S /R /E) . ROUND DUCT DOWN (S /R /E) TURNING VANE ELBOW RADIUS ELBOW, RECT RADIUS ELBOW, ROUND TRANSITION (ROUND TO ROUND/ RECTANGULAR TO RECTANGULAR) TRANSITION (RECTANGULAR TO. ROUND) SPIN -IN TAKEOFF CONICAL TEE TEE WITH TURNING VANES BRANCH TAKEOFF, RECT BRANCH TAKEOFF, ROUND BRANCH TEE, RECT CONICAL SPIN -IN TAKEOFF ROUND BOOT TEE ROUND --� 45' LATERAL 45' CONICAL LATERAL 4. R+ iv„,, mums, 7L11 Cr:71 6�. C. 10 200 0 RISE (R) RHDROP (D) AIR FLOW DIRECTION - SUPPLY AIR FLOW DIRECTION - RETURN OR EXHAUST DUCT END CAP FLEXIBLE DUCTWORK MANUAL VOLUME DAMPER REMOTE VOLUME DAMPER FIRE /SMOKE DAMPER - PROVIDE ACCESS FIRE DAMPER - PROVIDE ACCESS. MOTOR OPERATED DAMPER BACKDRAFT DAMPER CARBON DIOXIDE SENSOR WALL MOUNTED TSTAT WITH CONTROL UNE SUPPLY DIFFUSER SUPPLY GRILLE RETURN /EXHAUST GRILLE EQUIPMENT MARK DIFFUSER /GRILLE DESIGNATION ROUND DUCT GENERAL SYMBOL —I 02, XX' -XX' ) E xx' -xx' ) DKI xx' -xx' ) PITCH Tx a wa PITCH y• ror F- 8 ABBR DESCRIPTION 45 45. DOWN 90 AD ACCESS DOOR IN CEILING AD ACCESS DOOR IN WALL ALIGNMENT GUIDE ANCHOR AUTOMATIC CONTOL VALVE (3 -WAY) AUTOMATIC CONTROL VALVE (2 -WAY) BALANCING VALVE . BV BALL VALVE BOP BOTTOM OF PIPE ELEVATION BREAK BEV BUTTERFLY VALVE CAP CENTERLINE CL -EL CENTERUNE OF PIPE ELEVATION CHK CHECK VALVE CIRCUIT SETTER DETAIL TAG DN DOWN ELEVATION TAG FLOW ARROW GAS COCK GLOBE VALVE GV GATE VALVE IE INVERT PIPE ELEVATION PITCH LEFT PITCH RIGHT PLUG POC POINT OF CONNECTION PG PRESSURE GAUGE PRV PRESSURE REDUCING VALVE ROLLING 45 DOWN REDUCER REDUCING CONCENTRIC REDUCING ECCENTRIC RV • RELIEF VALVE SHEET NOTE DESIGNATION SLEEVE SOLENOID VALVE TEE DOWN TEE TH THERMOMETER LONG TAG 9 CHARCTERS MAX MEDIUM TAG 6 CHARCTERS MAX SHORT TAG 4 CHARCTERS MAX TOP TOP OF PIPE ELEVATION U UNION UP VERTICAL SLEEVE VALVE IN PIPE RISE OR DROP STR WYE TYPE STRAINER PIPING SYMBOL - BFW-- 0 —CA- - CHR- - CHS- -CR - -CS- - FOR - -FOS- - FOV- -G- - GLR-- — GLS - - HCR— HWS— LCR — — LPS- -MCR- -MG- -MPS- -PCR- -RL T ABBR DESCRIPTION MV AUTOMATIC AIR VENT BFW . BOILER FEED WATER BUCKET TRAP CA CONTROL AIR CHR CHILLED WATER RETURN CHS CHILLED WATER SUPPLY CR CONDENSER WATER RETURN CS CONDENSER WATER SUPPLY FLANGE FLEX FLOAT AND THERMOSTATIC FOR FUEL OIL. RETURN FOS FUEL OIL SUPPLY FOV FUEL OIL VENT G NATURAL GAS GLR GLYCOL RETURN. GLS GLYCOL SUPPLY HCR HIGH PRESSURE CONDENSATE RETURN HG HOT GAS . HPS HIGH PRESSURE STEAM HWR HEATING HOT WAER RETURN HWS HEATING HOT WATR SUPPLY LCR LOW PRESSURE COMENSATE RETURN LPS LOW PRESSURE SIAM MAV MANUAL AIR VENT MCR MEDIUM PRESSURE CUDENSATE RETURN METER . MG MEDIUM PRESSURE IATURAL GAS MPS • MEDIUM PRESSURE TEAM PCR PUMPED CONDENSAT RETURN PI PRESSURE INDICATOF RL REFER LIQUID RS REFER SUCTION TEMPERATURE PRESSURE EST PLUG TI TEMPERATURE INDICATC TS TEMPERATURE SENSOR VB VACUUM BREAKER VENTURI ABBREVIATIONS AC AF AFF AHU AMB ANTS B BDD BHP BI BOD BOT BTUH CC CFM CHLR CLG CNTFGL COMB COND CONT CONTR CP CRAC CT CU Cv CV CWP D DB DEG DIA DIM DISCH DMPR DN AIR CONDITIONING UNIT AIRFOIL ABOVE FINISHED FLOOR AIR HANDLING UNIT AMBIENT AIRFLOW MEASURING UNIT BOILER BACKDRAFT DAMPER BRAKE HORSEPOWER BACKWARD INCLINED BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNIT PER HOUR COOLING COIL CUBIC FEET PER MINUTE CHILLER . CEILING CENTRIFUGAL COMBUSTION CONDENSER / CONDENSATE CONTINUE / CONTROL CONTRACTOR CIRCULATING PUMP COMPUTER ROOM AIR CONDITIONING UNIT COOLING TOWER CONDENSING UNIT / CUBIC FLOW COEFFICIENT CONSTANT VOLUME CHILLED WATER PUMP DRAIN DRY BULB / DECIBEL DEGREE DIAMETER DIMENSION DISCHARGE DAMPER DOWN ABBREVIATIONS EA EAT ECONO EDH EER EF EFF ELEC ELEV EQUIV ESP EVAP EWT EXH EXT F FC FCU FD FLR FLTR FDIC. FPM FSD FT FTU FV GA GAL GALV GPM GWB H HC HD HORIZ HP HT HVAC HVACDCS HX • • ID IN KW L LAT LB LWT MBH MECH MOD MTD MVD NC NIC NO NTS OBD. OC OD OSA P PBD PD PL POC PT QD. RA REF REV RF RH RIO RPM SA SCFM SCH SECT SENS SF SL SMACNA SP SQ SS ST TBV TCV TDH TOD TOS TP TRNSN TSP TYP UBD UH UNO VA VAV VD VENT VEL VFO VI VIV W WB WG •Wr. EXHAUST AIR ENTERING AIR TEMPERATURE ECONOMIZER ELECTRIC DUCT HEATER ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY ELECTRIC ELEVATION EQUIVALENT EXTERNAL STATIC PRESSURE EVAPORATOR / EVAPORATIVE ENTERING WATER TEMPERATURE EXHAUST EXTERIOR / EXTERNAL FAHRENHEIT FORWARD CURVE FAN COIL UNIT FIRE DAMPER / FLOOR DRAIN FLOOR .. FILTER FURNISHED BY OWNER INSTALLED BY CONTRACTOR FEET PER MINUTE FIRE SMOKE DAMPER FEET FAN TERMINAL UNIT FACE VELOCITY . . GAUGE GALLONS GALVANIZED GALLONS PER MINUTE GYPSUM WALLBOARD HUMIDIFIER HEATING COIL HEAD • HORIZONTAL HORSEPOWER HEAT TRACE HEATING, 'VENTILATING, AND AIR CONDITIONING HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE (SMACNA) HEAT, EXCHANGER INDIRECT DRAIN / INSIDE DIAMETER INCH KILOWATT LONG / LENGTH LEAVING AIR TEMPERATURE POUND LEAVING WATER TEMPERATURE THOUSAND BTU PER HOUR MECHANICAL MOTOR OPERATED DAMPER MOUNTED MANUAL VOLUME DAMPER NORMALLY CLOSED / NOISE CRITERIA NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIMENSION OR DIAMETER OUTSIDE AIR PUMP PARALLEL BLADE DAMPER PRESSURE DROP / PUMPED DRAIN PLENUM POINT OF CONNECTION POST- TENSION SLAB QUICK DISCONNECT RETURN AIR REFERENCE REVISION RELIEF FAN RELATIVE HUMIDITY ROUGH -IN ONLY REVOLUTIONS PER MINUTE SUPPLY AIR STANDARD CUBIC FEET PER MINUTE SCHEDULE SECTION SENSIBLE SUPPLY FAN / SQUARE FOOT SOUND LINE (INSIDE DUCT INSULATION ) SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION STATIC PRESSURE . SQUARE . STAINLESS STEEL SOUND TRAP TOWER BYPASS VALVE TEMPERATURE CONTROL VALVE TOTAL DYNAMIC HEAD TOP OF DUCT TOP OF STEEL TOTAL PRESSURE TRANSITION TOTAL STATIC PRESSURE TYPICAL UPBLAST DISCHARGE UNIT HEATER UNLESS NOTED OTHERWISE VALVE VARIABLE AIR VOLUME VOLUME DAMPER VENTILATION / VENTILATOR VELOCITY VARIABLE FREQUENCY CONTROLLER VIBRATION ISOLATOR VARIABLE INLET VANES INSULATED DUCT / WATT / WIDE WET BULB (TEMPERATURE) WATER GAUGE WEIGHT MECHANICAL INDEX OF. DRAWINGS MECHANICAL DRAWING INDEX aFEEr f DESCRPi1ON 14001 MECHANICAL SYMBOLS, DWG INDEX, & ABBREV M002 SITE PLAN SCALE N/A AS NOTED M101 MECHANICAL SCHEDULES M201 LEVEL ONE MECHANICAL PLAN M202 LEVEL TWO MECHANICAL PLAN M203 ROOF MECHANICAL PLAN M300 MECHANICAL DETAILS N/A Viiisakakaw 1/8' =1' -0" 1/8%1'-0° 1/8' =1' -0' N/A GENERAL NOTES: 1. DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW EXACT ROUTING OR ALL TRANSITIONS /CONNECTIONS /OFFSETS REQUIRED. 2. COORDINATE ALL NEW WORK WITH EXISTING STRUCTURE AND HVAC. FIELD VERIFY EXISTING CONDITIONS. 3. ROUND CONNECTIONS TO RECTANGULAR DUCTWORK SHALL BE MADE WITH 45 DEG SADDLE TYPE TEES. 4. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 6' -0" WITH A MAXIMUM BEND OF 90', FLEX DUCT SIZE SAME AS DIFFUSER NECK SIZE. 90. BENDS SHALL BE 2 TIMES THE DIAMETER OF THE ROUND DUCT. 5. PROVIDE REMOTE TYPE VOLUME DAMPERS FOR ALL AREAS WITH INACCESSIBLE CEILINGS. YOUNG REGULATOR No.. 315 OR EQUAL. ALIGN DAMPER COVER PLATES. 6. LOCATE THERMOSTATS AS SHOWN ON DRAWINGS. MOUNT WALL THERMOSTATS AT 60" A.F.F. COORDINATE FINAL LOCATIONS WITH ARCH /ENGR /OWNER. 7 LOCATE THERMOSTATS FOR ALL TENATE IMPROVEMENT TERMINAL UNITS AT THE TERMINAL BOX WITH 20 FEET OF THERMOSTAT CONTROL WIRE ATTACHED TO THE THERMOSTAT. 8. PROVIDE CONNECTIONS AND TRANSITIONS AT EQUIPMENT AS REQUIRED. 9. INSTALLATION SHALL COMPLY TO ALL FEDERAL, STATE AND LOCAL CODES. 10. INSULATION OF DUCT WORK AND PIPING SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODE AND THE SEATTLE AMENDMENTS 11. DUCTS PENETRATING 1 -HR CORRIDOR WALLS WITHOUT OPENING INTO THE CORRIDOR. SHALL BE A MINIMUM 26 GAUGE STEEL. 12. ALL DUCT DIMENSIONS ARE ID (INTERNAL DIMENSIONS). ALL DUCT HEIGHTS ABOVE THE FINISHED FLOOR ARE TAKEN FROM THE DUCT'S ID DIMENSIONS. CONTRACTOR IS REQUIRED TO ADD TO THE DUCT ID WHEN THE DUCTWORK HAS INTERIOR INSULATION. ALL MECHANICAL ELEVATION ARE TO BOTTOM OF DUCT, BOTTOM OF PIPE. 13. MANUAL VOLUME DAMPERS TO 12" IN DEPTH SHALL BE SINGLE BLADE AND A MINIMUM OF 22 GAUGE. 13" AND ABOVE SHALL BE MULTIPLE BLADES AND A MINIMUM OF 18 GAUGE. 14. MANUAL VOLUME DAMPERS ARE REQUIRED AT EACH BRANCH DUCT GOING TO A SUPPLY AIR, RETURN AIR, AND EXHAUST AIR OUTLET OR INLET. 15. ACCESS DOORS SHALL BE REQUIRED AT EACH FIRE DAMPER, FIRE /SMOKE DAMPER, AND WHERE ACCESS TO ANY DEVICE IS REQUIRED FOR OPERATION OF THAT DEVICE. 16. USE UNISTRUT CONCRETE INSERTS, OR EQUAL, TO SUPPORT MECHANICAL EQUIPMENT OR DUCTWORK FROM THE P.T. SLAB. REVISIONS No changes shall be made to the scope of work without prior approval of NOTE: Revisions will Dieisiort, and may include additional plan rev ew f es.ttai Permit SEPARATE PERMIT REQUIRED FOR: ❑ lechantcaf iirElectrdcat E Iumbtng [was Piping City of Tukwila B t ! ING DIVISION FILE C Mar No.. 14‘ (O—Z$ Plan review approval is subject to errors and omissions. Approval of cot struction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie d Copy and conditions is acknowledged: By Date: City Of Tukwila 3UILDING DIVISION REVIEWED -OR — CODE COMPLIANCE fAPotintIVRID OCT 01 2U10 A� ViL City of Tukwila BUILDING tlillmlflm CRV�LA sFp 21 2010 PERMIT CENTER Mao —«A 4 a) w • 1 +. 13) iz O CO CA 2 y Commercial T.I. Permit 9404 East Marginal Way South, Seattle, WA Commercial T.I. Permit Drawing Title DRAWING INDEX Revisions No. Description Date Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No ' M001 or N 27 23 41 W 711.69 -------------------------- -__ _ 41_1111.11Lill I� I1 LLLJJ- ROPERr( I LINE ZONE 000000000000000000110000000000 N 22 31 55 W 431.95 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / w / i/ q. / / / / / / / / / / / / / / / / / / / q. / / / / / /a, EAST MARGINAL WAY SOUTH -Thy11011900090091101196 NlR EXISTING BUILDING D PRUECT NORTH 0 10'0' 40' 60' LEVEL - SSG 0. ROOF EL 90' -5 1/2" -.- LEVEL - SSG B.03OOF EL: 55' -5 1/2" -e- LEVEL - UPPER PAPET EL 43' -3 1/2" -e LOW ROOF TOS ELS -5 1/2" -4- LEVEL 2 EL 30' -3/2" EQUIPMENT ELEVATION LOOKING EAST SCALE: 1/16' =1' -0' 2 4- LEVEL 1 EL 11-9/2" 2006 WSEC COMPLIANCE 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE 14-1A THROUGH 14 -1G AND 1411.1 OF THE WSEC AND AS INDICATED IN THE CONTRACT DOCUMENTS. 2. PROVIDE DEADBAND BETWEEN HEATING /COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY SECTION 1412.2 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 3. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION 1412.4 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. PROVIDE BALANCING DEVICES IN All. BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION 1412.7 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDSyfOR CONSTRUCTION OF GALVANIZED DUCTWORK. AU. DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION 1414.1 OF THE WSEC. DUCT TAPE NOT ALLOWED. DUCTWORK STATIC PRESSURE AND SEAL CLASS: WATER COLUMN . SEAL CLASS 1/2 TO 2 INCHES 2 TO 3 INCHES ABOVE 3 INCHES SEAL TRANSVERSE JOINTS SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS SEAL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS 6. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION 1414.2 OF THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL DUCT TYPE LOCATION R -VALUE SUPPLY /RETURN NOT WITHIN CONDMONED SPACE R -7 (INCLUDE APPROVED WEATHERPROOF BARRIER) SUPPLY/RETURN/ OUTSIDE AIR IN GROUND OR CONCRETE R -5.3 OUTSIDE AR . WITHIN CONDONED SPACE (NOT CONSIDERED PART OF THE BUILDING ENVELOPE) R -7 (DAMPER AT ENVELOPE PENETRATION) SUPPLY WITHIN CONDITIONED SPACE R -3.3 7. ALL PIPING Stall BE INSULATED AS REQUIRED BY SECTION 1415.1 OF THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL SYSTEM/TEMP (F) INSULATION CONDUCTIVITY PIPE DIAMETER =1' >1' -0 >2' -4' >4' -6' >6' INSULATION THICKNESS HEATING: >350 .32 -.34 2.5 2.5 3.0 3.5 3.5 251 -350 .29 -.31 2.0 2.5 2.5 3.5 3.5 201 -250 .27 -.30 1.5 1.5 2.0 2.0 3.5 141 -200 .25 -.29 1.5 1.5 1.5 1.5 1.5 105 -140 • .24 -.28 1.0 1.0 1.0 1.5 1.5 DOMESTIC: 105+ .24 -.28 1.0 1.0 1.5 1.5 1.5 45 -65 .24 -.27 0.5 0.5 0.5 0.5 0.5 COOLING: 40 -55 .23 -27 0.5 0.75 1.0 1.0 1.0 <40 .23 -27 1.0 1.5 1.5 1.5 1.5 8. INDMDUAL ZONE TERMINAL UNITS AND HVAC SYSTEMS SERVING PORTIONS OF THE BUILDING HAVING LESS THAN 24 -HOUR OPERATION SHALL BE SHUT OFF DURING UNOCCUPIED PERIODS AS REQUIRED BY SECI1ON 1432.1 OF. THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 9. SUPPLY AR AND WATER TEMPERATURES SHALL BE AUTOMATICALLY RESET AS REQUIRED IN SECTION 1432.2.1 AND 1432.2.2 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 10. Al AR SYSTEMS SHAD. BE PROVIDED WITH A 1002 CAPABLE AR ECONOMIZER CAPABILITY AS REQUIRED BY THE SECTION 1413.1, 1423 AND 1433 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 11. AR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOUNG LOAD AS REQUIRED IN SECTION 1413.3 OF THE WSEC. 12. WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING THE TOTAL CONCURRENT COOLING LOAD SERVED BY THE CONNECTED TERMINAL EQUIPMENT LACKING ARSIDE ECONOMIZER AS REQUIRED BY SECTION 1413.1, 1413.2, AND 1433 OF THE WSEC. 13. SIMULTANEOUS HEATING AND COOLING TO INDMDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE. CONTROL SEQUENCES EXCEPT WHERE PERMITTED IN SECTION 1435, EXCEPTIONS 1 THROUGH 4 OF THE WSEC. 14. VARIABLE FREQUENCY DRIVES SHALL BE PROVIDED FOR VARIABLE FLOW HEATING AND AR HANDUNG SYSTEMS AS REQUIRED BY SECTION 1438 OF THE WSEC AND AS DESCRIBED IN THE CONTRACT DOCUMENTS INCLUDING TEMPERATURE CONTROL SEQUENCES. 15. • ELECTRIC WATER HEATERS LOCATED IN UNCONDITIONED SPACES OR ON CONCRETE FLOORS SHALL BE SEPARATED FROM THE SUPPORTING SURFACE WITH R -10 INSULATION AS DESCRIBED IN SECTION 1441 OF THE WSEC. 16. DOMESTIC HOT WATER CIRCULATION PUMPS SHALL. BE SHUT DOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTTON1442 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 17. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER TABLE 14-4 AND SECTION 1437 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 18. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION 1416.2.4.3 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM. 19. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION 1416.2.4.2 OF THE WSEC. AS A MINIMUM, THE MANUALS SHALL INCLUDE 1. SUBMITTAL DATA. 2. OPERATION AND MAINTENANCE DATA FOR EQUIPMENT. 3. NAMES AND ADDRESSES OF SERVICE AGENCIES. 4. HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION. 5. NARRATIVE OF HOW SYSTEM IS INTENDED TO OPERATE. 20. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION 1416.2.2 OF THE WSEC. 21. COMMISSIONING SHALL BE PROVIDED AND A REPORT OF COMMISSIONING BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION 1416 OF THE WSEC. MiOIZ9 REVIEWED FOR CODE COMPLIANCE APB" MINE OCT 01 210 City of Tukwila BUILDING niviRinm RECEIV CITVOFTU lA SEP 21 2010 PERMIT CENTER ROOF COVERAGE CALCULATION ROOF LOCATION EQUIPMENT (SF) DUCTWORK (SF) STRUCTURES (SF) TOTAL ROOF AREA % ROOF COVERAGE ENTRY 375.0 • 0.0 0.0 735.0 51.0 HANGER 0.0 0.0 0.0 15,685.0 0.0 BUILDING TOTAL 375.0 0.0 0.0 16,420.0 2.3 NOTE: 1. We Build Value CU 44 ON ift "`" W c mom 8 tic d �C)C') 3 o.. N a, ▪ Ovv ✓ iv ▪ °- • CL La. 711. 0 4.• co O as • 1 co Commercial T.1. Permit Commercial T.I. Permit Drawing Title SITE PLAN Revisions No. Description Date Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022. Consultant Project No Owner Project No Drawing No M002 GRILLE, REGISTER AND DIFFUSER SCHEDULE EQUP. B NO. SERVICE 11M4UFACTURER SUPPLY AIR <55 DEG DESCRIPiiON NOTES STYLE MATERIAL FRAME FACE SIZE NECK SUE MAX CFLI BRANCH DUCT NC COLOR Al FLLOR SUPPLY DIFFUSER TDUS CT 480 FLOOR . SAID. LAY -IN LENGTH PER PIM X 12' WIDE PER PUN 300 CFA/ IF N/A 23 wHDE 2 RECT RECT ROUND RECT RECT RECT RECT ROUND RECT RECT RECT RECT RECT INSULA11ON TYPE 81 LINEAR SUPPLY SLOT DFFUSER . TiTUS ML-39 4 -SLOT AWMINUM LAY -VI SEE PLANS X 8' WIDE . PER PLAN 425 12 26 WHITE 1 1.5" 1' 1.5" 3" 2" 1.5" 1" 1.5" 3" • 2" 3' 3" 2" DENSITY Cl RETURN GRILLE TITUS 50F EGGCRATE AWMINUM LAY -W 24x12 22X10 600 24X12 <12 VINE R' VALUE C2 RETURN GRILLE TITUS' 50F ' EGGCRATE ALUMINUM LAY -IN 24x24 22X22 1200 24x24 <12 WHITE FACING (JACKET) C3 RETURN GRILLE TRUS 50F EGGCRATE AWMINUM LAY -i1 24x48 2E448 2400 24x48 <12 YAM REMARKS [1.] D1 RETURN Gl L E TTiUS 35ORL SINGLE DEF STEEL. SURFACE NECK +1.75" . • 24X12 600 24X12 26 WHITE D2 RETURN MILLE TRUS 350RL SINGLE DEF STEEL SURFACE NECK +1.75' 24x24 1200 24x24 29 WHITE D3 RETURN GRILLE TTTUS 350RL. SINGLE DO? STEEL SURFACE NECK+1.75' 24x48 2400 24x48 32 WHRE El EXHAUST GRILLE 1TWS 350RL SINGLE DEF Situ. SURFACE NECK +1.75' 8X8 100 8 <10 WHITE E2 DOWUSt GPoLE 1TNS . 35Oit1. SINGLE DEF STEEL SURFACE NECK +1.75' 10X10 210 8 <10 WHITE E3 EXWIIIST GRILLE TTRJS 350RL SINGLE DEF STEEL SURFACE i ECK +1.75• 12X12 375 10 10 WHITE E4 EXHAUST GRILLE 1Tili5 350RL. SINGLE DEF STEM SURFACE NECK +1.75' 14X14 • 550 12 27 WHITE E5 EXHAUST GRILLE 1IIUS 350RL SLNGIE DEF STEEL SURFACE NECK +1.75' 18X18 850 14 29 *IRE E6 EXHAUST GPoLLE 1TN5 35081. SINGLE off SiEEB. SURFACE NE2(+1.75' 24X24 1875 20 33 WHITE J1 LINEAR RETURN SLOT DIFFUSER TTTUS MLR-39 4-SLOT AWMINUM LAY-IN SEE PLANS PER PLAN -- WHITE 1. PROVIDE PLENUM CAN 2. PRC'VIDE OPPOSED BLADE DAMPER DUCT INSULATION SCHEDULE -- OFFICE W /PLENUM RETURN . DUCT FUNCTION. SUPPLY AIR <55 DEG SUPPLY AIR <55 DEG SUPPLY AIR <55 DEG SUPPLY AIR <55 DEG SUPPLY • AIR <55 DEG RETURN AIR RETURN AIR RETURN AIR RETURN AIR RETURN AIR OUTDOOR AIR INTAKE GENERAL EXHAUST INT /EXH PLENUMS L.00A71ON INDOOR INDOOR INDOOR OUTDOOR OUTDOOR INDOOR INDOOR INDOOR OUTDOOR OUTDOOR INDOOR INDOOR INDOOR SHAPE RECT RECT ROUND RECT RECT RECT RECT ROUND RECT RECT RECT RECT RECT INSULA11ON TYPE WRAP UNED WRAP WRAP UNED WRAP UNED WRAP WRAP UNED WRAP WRAP BOARD THICKNESS 1.5" 1' 1.5" 3" 2" 1.5" 1" 1.5" 3" • 2" 3' 3" 2" DENSITY 0.75 PCF 2.0 PCF • 0.75 PCF 0.75 PCF 2.0. PCF 0.75 PCF 2.0 PCF 0.75 PCF 0.75 PCF 2.0 PCF 0.75 PCF 0.75 PCF 3.0 PCF R' VALUE 3.3 3.3 3.3 7.0 7.0 3.3 3.3 6.4 7.0 7.0 7.0 7.0 7.0 FACING (JACKET) FOIL FACED N/A FOIL FACED FOIL FACED N/A FOIL FACED N/A FOIL FACED FOIL FACED N/A FOIL FACED FOIL FACED FOIL FACED REMARKS [1.] REMARKS: 1. INSTALL EXTERNAL WRAP FROM RELIEF AR CONTROL DAMPER OR BACKDRAFT DAMPER TO PLENUM CONNEC11ON 2. LINE ALL TRANSFER AIR DUCTS WITH 1", 2.0 PCF DUCT UNER ELECTRIC WALL HEATER SCHEDULE EQUIP. ID NO. SERVICE / LOCATION MANUFACTURER MODEL L -4 PERFORMANCE BLDG. RELIEF ELECTRICAL NOTES CFM INPUT KW STEPS FAN HP AMPS VOLT PHASE UN-1 VESTBULE / MAIN ENTRY QMARK DSHO7A 5750 N/A 3.75 1 N/A DRIVE 277 1 1, 2, 3, 4, 5 UH-2 VESTIBULE / WEST COMA. D4TR' CMMB( DSHO7A 5750 N/A 3.75 1 N/A INSPECTION 277 1 1, 2. 3, 4, 5 NOTES: 1. HEATER PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY EL.ECiRICAL CONTRACTOR 2. INTEGRAL TAMPER PROOF T -STAT 3. SURFACE MOUNT iNSTALLATION 4. TfiIPERATURE SEIPOINT 45 DEGREES 5. FINISH To BE CONFIRMED BY ARCHITECT LOUVER SCHEDULE TAG L -1 • . L-2 L -3 L -4 SERVICE BLDG. RELIEF LOBBY OSA INTAKE BLDG. RELIEF BLDG. RELIEF LOCATION WEST LOBBY WALL WEST LOBBY WALL WEST GALLERY WALL WEST GALLERY WALL MANUFACTURER COOK COOK YODEL 100 ACES EQUIPMENT • INUNE CENT. INUNE CENT. DRIVE MANUFACTURER RUSKIN RUSKIN RUSKIN RUSKIN MODEL ELF - 6375 DX ELF - 8375 DX ELF - 8375• DX ELF - 8375 DX ACTUATOR TYPE INSPECTION ELECT ELECT PERFORMANCE PERFORMANCE NITROGEN au 620 700 AIRFLOW (CFA) 1,600 1.600 10,000 10,000 VEWCRY (FPM) 350.9 350.9 350.9 350.9 PHASE : 1 BHP • 0.121 0.123 PHYSICAL 0.167 0.167 VOLT 120 DIMENSIONS (LAWN) 48 x 24 x 6 48 x 24 x 6 120 x 36 x 6 120 x 36 x 6 FREE AREA (SQ. Fl) 4.56 4.56 28.5 28.5 FINISH GALV. GALV. GALV. GALV. OPTIONS WEIGHT 50 100 FILTER / DRYER: R -22, LIQUID LINE MOTORIZED DAMPER MD-1 NO W -3 MD-4 MOTORIZED W3IPFR YES NO NOTES: i i EXHAUST FAN SCHEDULE . TAG EF -1 EF -2 SERVICE TOILET EXHAUST ELEC. RM. EXHAUST LOCATION . ROOF - 904 BLDG. 904 BLDG. ELEC. RM. JOINT TYPE LOCATION AWS A5.8, BAg -1 OR BAg -2 SILVER SOLDER EQUIPMENT GALLERY ASME B16.22 WROUGHT MANUFACTURER COOK COOK YODEL 100 ACES 100 -SQNB FAN TYPE INUNE CENT. INUNE CENT. DRIVE BELT BELT WHEEL TYPE CENTRIFUGAL CENTRIFUGAL WHEEL DIAMEiER CoNSr CLASS ACTUATOR TYPE INSPECTION ELECT ELECT PERFORMANCE NITROGEN au 620 700 iSP 0.5 0.25 RPM 1524 1508 24V 24V 24V ELECTRICAL PHASE : 1 BHP • 0.121 0.123 HP 0.167 0.167 VOLT 120 120 PHRASE 1 1 DISCONNECT SIZE HENRY TYPE 203 FURNISHED/INSTALLED EC / EC EC / EC INTERLOCK BY ELECT. CONTRACTOR PHYSICAL WEIGHT 50 100 FILTER / DRYER: R -22, LIQUID LINE SPORLAN CATCH -ALL CW- SERIES ACCESSORIES SPORLAN TYPE 6000 MOTORIZED W3IPFR YES NO NOTES: 1 NOTES: 1.' ELECTRICAL CONTRACTOR TO PRONDED INTERLOCK BETWEEN MOTORIZED DAMPER AND EXHAUST FAN MOTOR „imago, ,Rommommo.- •■■.. ■••■ i REFRIGERATION PIPING (23 2300) ABOVE MOUND IRBAB - 2' + SMALLER MD -3 MD -4 SERVICE PIPE MATERIALS RA GALLERY ASTM B280 TYPE ACR COPPER JOINT TYPE LOCATION AWS A5.8, BAg -1 OR BAg -2 SILVER SOLDER FITTING MATERIAL GALLERY ASME B16.22 WROUGHT FLANGES N/A GASKETS N/A BOLT TYPE N/A • MANUFACTURER RUSKIN TEST /NBPECTnON RUSKIN RUSKIN UMC WELD PROCEDURE WELD INSPECTION (Visual, X -ray, etc ?) ACTUATOR TYPE INSPECTION ELECT ELECT - Media (Air, Water, Aaron, Nitrogen, etc ?) NITROGEN - Duration 2 HOURS - Pressure (psi or ft. head) 150 PSIG OR 120% OF WORKING PRESSURE - Responsible (City, Owner, Owner Rep., etc'?) OWNER REP 24V 24V 24V VALVES - 5OO11 PHASE : 1 PACKLESS: SOLDERED • HENRY TYPE 626 ANGLE SOLDERED HENRY TYPE 647 HAND EXPANSION: SOLDERED HENRY TYPE 629 CHARGING / PURGING: SOLDERED HENRY TYPE 623 GLOBE: SOLDERED SIZE HENRY TYPE 203 CHECK : STRAIGHT, SOLDERED 120x36 HENRY TYPE 120 MISCELLMEOUS DEVICES SOLENOID VALVES SPORLAN E3 OR ES SERIES FILTER / DRYER: R -22, LIQUID LINE SPORLAN CATCH -ALL CW- SERIES STRAINERS SPORLAN TYPE 6000 MOISTURE - INDICATING SIGHT GLASS SPORLAN 'SEE ALL' SA SERIES MOTORIZED DAMPER SCHEDULE TAG MD -1 • MD -2 MD -3 MD -4 SERVICE LOBBY RA GALLERY RELIEF NR RELIEF AR LOCATION LOBBY CEILING GALLERY GALLERY GALLERY EQUIPMENT • • MANUFACTURER RUSKIN RUSIGN RUSKIN RUSKIN MODEL ACTUATOR TYPE ELECT ELECT ELECT DDCr ELECTRICAL VOLT 24V 24V 24V 24V PHASE : 1 1 1 1 PHYSICAL SIZE 48x24 160X18 120x36 120x36 5c::)U of WoR.K We Build Value • 711 •F .i. d v 4.0 cu en Museum of Flight REVIEWED FOR CODE COMPLIANCE EA. ! WIVE OCT 01 MU City of Tukwila BUILDING flIVIRin im M(O 128 WM( awn 1 LA fro 21 2010 PERMIT CENTER Commercial T.I. Permit Drawing Title MECHANICAL SCHEDULES Revisions No. Description Date Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No MIQI 2 "GAS METER �r ' 6 "e EX ii i t s/•■ft-1 1' ` I ''1 !i Iii._ I� it it ' 1i 1 i , i ri i1 1j U 11 • ! , I! it _1 1 • t I to i'`t i, , I; 1 , ( i TRANSFER FAN LOCATED AT 11' AFF, TIP 24x48 EGGCRATE RA GRILLE MOUNTED AT 10' AFF (4 T(P) =OH _H /_ r"S 1/ TF -01 y/ %1/ 'TF -04 TF -03 I% // -16 "x18 "_EXH - H GAMMON OH.. - -H-- Ha.... / / / / / I I TF -07 INSULATED BLANK OFF PANEL SCREENED OPENING 11' -09/16 • MD -2 WITHIN RETURN AIR PLEN jl iI 11 I" -- 18x12 TRANSFER i GRILLE (2 TYP) 1 It 20x20 TRAN I ,FERN ti Ii — — (5)48x24 EGGCRATE RA GRILLES. LOCATE 10 F. A.F.F. IN BOTTOM OF RETURN AIR PLENUM LINEAR DIFF. TYP 12 "e SA TYP '20 "x20" OAS / / I // I 1 1/2 "e CD UP TO RTU -1 TO RTU -1 I ;I 1 1/2"e GAS (LP) ; ,j UP TO ROOF 1 1/2"0 GAS (LP) - - 1\ IBS till . ,� n$� � �� ( �.1 �1 l.� 12 a �XH '/ ! �� 12x12 AD • 11 IOOCFM 10 "e EX 1 1/2 "e (E)GAS VERIFY LOC. 1 1 1/2"e /GAS (HP)' = - -Y II REBALNCE EXIST. EXHAUST FAN FOR 325 CFM Nammumra% 75CFM 14x14 EXH i UP W /SL 1 1 /2 "e C _I! 1 "I •, I 6"x6" EXH; `✓ 1 ._._.S 1 20 "x20" RA 44 "x44" SA UP TO AHU -1 15"x120" RA GRILLE i 44 "x44" SA DUCT DN. AND TRANSITION TO 44" DIA..IN VERTICAL. 50CFM I 6 a EXH GWH FLUE CONNECT TO EXIST. EXHAUST DUCT II H /10 SCO?E' OF WoLb4. P 28 t CODE FOR \ - ' CODE COMPLIANCE PPR go OCT 01 2 id BUIL City of Tukwila RING I ll /isinKl LEVEL ONE - MECHANICAL PLAN M201 1/8" =1' -0" ciTV OF Th W A SEP 21 2010 PERMIT CENTER U cri pc F-UF CI: 44c LIJ WVZ G'O We Build Value a) To a) Alm• IW s} c 5: w o g co 2 Commercial T.1. Permit d Ibe U) 3 C h. 2 i+ N W O a) Commercial TA. Permit Drawing Title LEVEL ONE - MECHANICAL PLAN Revisions No. Description Drawn by Author Checked by Checker. Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No Date M201 A � X fi r , i ! � . ■ i \ I 1 1� • ,_. }' j,'/ , • . ,' B1 8' FLOOR SUPPLY GRILLE 12' FLOOR GRLLE, (5 TIP) 4 k Y. 4.f . y ' \ ti t- � i �! .:. f . I K`]lti +� n.. ^ -. . Gfl2� . l:e :... .- . "m.— - J . - " " • trUCf: hn RVk:K.. IVC ..ka4 % / ( — • UH -1 I ,\ t , ! • /- . - / - J _41;-?". r� d . t p 9 !i . �,..a �., ;. .._' 4 �..._....,...,. a ...�...,.Y It/ ate ..i, P 28 t CODE FOR \ - ' CODE COMPLIANCE PPR go OCT 01 2 id BUIL City of Tukwila RING I ll /isinKl LEVEL ONE - MECHANICAL PLAN M201 1/8" =1' -0" ciTV OF Th W A SEP 21 2010 PERMIT CENTER U cri pc F-UF CI: 44c LIJ WVZ G'O We Build Value a) To a) Alm• IW s} c 5: w o g co 2 Commercial T.1. Permit d Ibe U) 3 C h. 2 i+ N W O a) Commercial TA. Permit Drawing Title LEVEL ONE - MECHANICAL PLAN Revisions No. Description Drawn by Author Checked by Checker. Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No Date M201 eF � — 111111111011Piegagoo —. ED keK j 1 1 /2 "o GAS (HP) 6' FLUE UP &DN 14 "x14" EXIT A:5 ) I A.8 i 44'x44" SA UP TO AHU -1 41.111".- .sco?� of way.. LEVEL TWO - MECHANICAL PLAN M202) 1/8" = 1' -0" 1zs i B i �- / - 4I --REVIEWED FOR CODE COWPLIANCE APPRovEn OCT 0 i 2010 / City of Tukwila BUILDING �I11� inFi crRANALA up 21 2010 PERMIT CENTER \ c 6 rip Amp I- 0 cu sa. E Commercial T.1. Permit 9404 East Marginal Way South, Seattle, Commercial T.I. Permit Drawing Title LEVEL TWO - MECHANICAL PLAN Revisions No. Description Date Drawn by Author Checked by Checker Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No M202 eF-- eG ) . eG7 F- / • 1; I. • k: 4 . _ ...-- ._. --. C. - - • ,//// A.2 i3; ii 120 "x36" RELIEF LOUVER/ / t I; CU -1 42x70 SL RETURN AIR DUCT TO AIR PLENUM, SEE ARCH DWG REFER LINES 1 1 /2 "CD 1 - ----- - -- - 3'e GAS (LP) CONNECT TO EXIST VERIFY LOC. EXIST. GAS TO REMAIN EF -1 1 ,/ 2 "e GAS (LP) TO RTU -1 I 1 1/2 "e GAS (LP) DN 1 1 /2 "e GAS (HP) DN / (V—6 "e EXH GWH FLUE i 1 eJ _-+ eGtRr7 W• ROOF PLAN .# \ \\ \ \. \ \ ( A.5 /i 120'x36" RELIEF LOUVER • I I ■ ...-•/r' 1/8" =1' -0" MECHANICAL f .. \ .;\ i •". • M RE— MO SEP 21 2010 PERMIT CENTER — - —.REVIEWED" F( CODE COMPLIANCE OCT 0 it City of Tukwila BUILDINP.nivigifM 6 cii }}.. < 0 U °' N y O O co -2 (-) ,§":42' � -5_ gcV gcqgs wr my( I i 1(2 F3I - — - ..4......c.„-.- w a 401 ac t. O co E Commercial T.I. Permit 9404 East Marginal Way South, Seattle, WA Commercial T.I. Permit Drawing Title ROOF PLAN - MECHANICAL PLAN Revisions No. Description Date Drawn by Author Checked by Checker Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No M203 i i UPPORT HANGER BAND FROM STRUCTURE MINIMUM RADIUS OF (1.5) *(FLEX DIA) NOTE: ALL SUPPLY AIR DUCTWORK TO BE INSULATED DOWN TO AND INCLUDING DIFFUSER NECK, UNLESS OTHERWISE INDICATED. FLEXIBLE DUCT CONNECTION (7' -0" MAXIMUM LENGTH). SAME SIZE AS DIFFUSER NECK UNLESS NOTED OTHERWISE. DIFFUSER NECK, SIZE AS NOTED ON PLAN. . M300 MODULAR DIFFUSER CEILING, SEE ARCH PLANS CEILING DIFFUSER DETAIL SCALE: NONE CAULK WALL PENETRATION, CUT & PATCH BY G.C. EXHAUST LOUVER CAULK 16 GA SHEETMETAL SLEEVE BACKDRAFT DAMPER (SEE NOTE 1) BIRDSCREEN LOUVER OPENING. PERIMETER WALL NOTE: 1. MOTORIZED DAMPER REQUIRED IN SOME JURISDICTIONS 2. SIZE EXH. LOUVER © 1000 CFM & 45% FREE AREA EXHAUST. LOUVER INSTALLATION DETAIL M300 SCALE: NONE SHEETMETAL FLASHING STRUCTURE ABOVE -� SPRING ISOLATOR (TYPICAL) THREADED ROD (TYP) OPTIONAL SOUND LINED INTAKE, SEE PLANS SEE PLAN FOR DUCT SIZE (TYPICAL) MOTOR /BELT GUARD \- MOTOR ON FLEX CONNECTION ADJUSTABLE (TYPICAL) BASE OPTIONAL SOUND LINED DISCHARGE, SEE PLANS IN -LINE CENTRIFUGAL FAN SOUTH GALLERY WALL 12" ti SCOPE oF \s//g- SEAL SCREW OR LAG FAN TO FACTORY CURB LEVELED ROOF CURB BY GENERAL CONTRACTOR FAN BASE SIZE OD CURB SIZE 00 0 COMPRESS SOUNDUNING 1/2" TO SLIP INTO BDD DUCT SIZE BDD - 1 ROOF OPNG :DI + 1 1 2 2x8 MINIMUM SCREW OR NAIL BDD TO ROOF 7PROVIDE 1" SOUNDUNING FOR FIRST 10' ON FAN INLET NOTES: Oj EXACT BDD AND CURB SIZE MUST BE CHECKED FROM EQUIPMENT SUBMITTALS. FINAL RESPONSIBILITY FOR CORRECT BDD AND CURB SIZE WILL BE INSTALLER'S 2 MOTORIZED DAMPER REQ. IN SOME JURISDICTIONS 3 RUN ROOFING MATERIAL TO TOP OF FAN CURB, BY G.C. EXHAUST FAN INSTALLATION DETAIL RTU -1 FASTEN UNIT TO CURB WITH 1/4" SCREWS ® 48 "O.C. -i S?S7S Alc WOOD NAILER FACTORY CURB SCALE: NONE 72" ROOFING MEMBRANE AND RIGID INSULATION (BY GC c(1 VSOCISlSA8158118 3/8 "x3 1/2" BOLT OR EMBED @ 36 "O.C. 5" CONCRETE PAD (BY GC) ROOFTOP UNIT CURB CONSTRUCTION DETAIL SCALE: NONE CAULK WALL PENETRATION, CUT & PATCH BY G.C. DRAINABLE LOUVER. BLADES (TYP.) CAULK PERIMETER WALL 16 GA SHEETMETAL SLEEVE BACKDRAFT DAMPER (SEE NOTE 1) BIRDSCREEN LOUVER OPENING NOTE: 1. MOTORIZED DAMPER REQUIRED IN SOME JURISDICTIONS 2. SIZE INTAKE LOUVER 1. 700 CFM & 45% FREE AREA OSA INTAKE LOUVER \� INSTALLATION DETAIL REVIEWED FOR CODE COMPLIANCE oc-i• o ; mu City of ►Tukwila BUILDING nIVIRI(1rI CI1YR0�'Ti)RfMLA SFP 21 2010 PERMIT CENTER I_ U Commercial T.I. Permit 9404 East Marginal Way South, Seattle, WA Commercial T"1" Permit Drawing Title MECHANICAL DETAILS Revisions No. Description Date Drawn by UMC Checked by DM Date August 18, 2010 Project No 210022 Consultant Project No Owner Project No Drawing No M300