Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M10-132 - WESTFIELD SOUTHCENTER MALL - BAYOU GRILL
BAYOU GRILL 2600 SOUTHCENTER MALL FC -5 M10 -132 City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 9202470010 Address: 2600 SOUTHCENTER MALL TUKW Project Name: BAYOU GRILL Permit Number: M10 -132 Issue Date: 10/14/2010 Permit Expires On: 04/12/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: DAVID WU Address: TSE ARCHITECTS , 12930 NE 178 ST 98072 Email: DAVID@TSE- AEP.COM Contractor: Name: ALLEN & L CONSTRUCTION INC Address: 12836 65 AV S , SEATTLE WA 98178 Contractor License No: ALLENLC974C 1 Phone: 206 - 227 -6760 Phone: 206 772 -0901 Expiration Date: 02/21/2011 DESCRIPTION OF WORK: YENANT IMPROVEMENT BUILD -OUT FOR NEW FOOD COURT RESTAURANT. TYPE I HOOD INCLUDED Value of Mechanical: $20,000.00 Fees Collected: $428.56 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Date: 10 111-1 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform - . - work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: /o -/`7 —r&' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -132 Printed: 10 -14 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 9202470010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Tenant: BAYOU GRILL Permit Number: M10 -132 Status: ISSUED Applied Date: 09/28/2010 Issue Date: 10/14/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 12: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 13: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. doc: Cond -10/06 M10 -132 Printed: 10 -14 -2010 �J��t�A wqs City of Tukwila r k 2 Department of Community Development O ►" ' 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14: Local U.L. central station supervision is required. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 17: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 M10 -132 Printed: 10 -14 -2010 0 City of Tukwila �l Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 7° — l ` rc2 doc: Cond -10/06 M10 -132 Printed: 10 -14 -2010 CITY OF TUKV'A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. biO- 7 IA co— 132.. Plumbing /Gas Permit No. i'16 10- MI-I Public Works Permit No. Project No. (For office use, only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: ! 20 2'' ?so 10 Suite Number: FG #Y Floor: 1000 Co 14 AT New Tenant: ® Yes .. No Site Address: 633 S0terH CParfreae MALt� Tenant Name: CAW a at Property Owners Name: ifkitSY rjirl•P C0141oltAli pi Mailing Address: a3 f+o , Sci'TF # -01 r S City 1 11�•- CONTACT PERSON — who do we contact when your permit is ready tobe issued Name: A t ihr -crrp CAavip Ii 4) Mailing Address: 121 3 o lig 17811i g7. E -Mail Address: tit yid t t5R dep. cobs. Wif State `1B Ion Zip Day Telephone: 1%300 viN1l1L.1,0. (2o6' b© City Fax Number: k 'Pei-2. State Zip (42J7 48 i- 631" GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg4) for. Plumbing and. Gas.Piping.(pg 5)) ( T =. T T isrirr) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: State Zip Expiration Date: ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: 7SE crf; Tf -C71 C A>J OFD 1-1,444) Mailing Address: 12 9 30 i I -341 ST , JOOO/ N vi(,($- City DAVIO 1414 Contact Person: E -Mail Address: 4.14,60t@ -tse-- me. CAP-% Wig 9 m1-2- State Zip Day Telephone: 14 tits <8 j— b 601 Fax Number: (t 217 (Ili-- 651'1 ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: Ago %EiN j', ;000.14.0, •2 -loo— I1aT& A • /i •, gflcf-vsa� City Contact Person: S1 4. 1401JAILO Day Telephone: E -Mail Address: StiJ.L— 1%PW4ra 40OssA,k.. Com, Fax Number: H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh 1 b oo 41 State Zip C4201 bo _ o�� (4, 'f6z -1 .r► Page 1 of 6 MECHANICAL PERMIT 1ENPIAIMATIOIN. c air Ygr rr) MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Slat Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): S 20/ 000. Scope of Work (please provide detailed information): TENANT IMPROVEMENT BUILD -OUT FOR NEW FOOD COURT RESTAURANT, TYPE I HOOD INCLUDED Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ® Replacement .... ❑ Fuel Type: Electric ® Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Air Ilandling Unit >10,000 CFM Qty Unit Type: Fire Damper Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Furnace >100K BTU Evaporator Cooler Diffuser 10 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 1 15 -30 HP /1,000,000 BTU Suspended-Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 3(1 -50 HP /I.750,000 BTU Appliance Vent Hood and Duct 2 Emergency Generator 50- IIP/1;750,000 BTU Repair or Addition to IlcatfRefrig /Cooling System Incinerator - Domestic Other Mechanical Equip meat MAKE -UP AIR 1 Air Handling Unit <10,000 CFM 1 Incinerator Comm /Ind 11 .Appl¢uauns,1ornh.Application, 0111 rt,e 2010 Appltcal nnw 7-2010 Penn0 Application dot lit-..4,d 7.)11111 Pauc 4 of Staff Initials: , , L. 1 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by "the plicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTJiIORIZED AGENT: Signature: Print Name: GALvI, 1.-£e Day Telephone: Date: °1/21/ 1010 (t9) 24,r_ 3-02* Mailing Address: 14.14 pa sate 14,4* cou44,1- %6A*412.04.0.4a ZScolvo / i IS& City State Zip Date Application Accepted: 01 - )-2 -�0 Date Application Expires: H:\ Applications \Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 CI of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R10 -02079 Initials: WER Payment Date: 10/14/2010 User ID: 1655 Total Payment: 2,574.50 Payee: BING - CHYWAN LEE SET ID: 1014 SET NAME: BAYOU GRILL SET TRANSACTIONS: Set Member Amount D10 -267 1,476.90 EL10 -0765 350.50 M10 -132 342.85 PG10 -134 404.25 TOTAL: 1,476.90 TRANSACTION LIST: Type Method Description Amount Payment Check 1464 2,574.50 TOTAL: 2,574.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR GAS - NONRES MECHANICAL - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE 000.322.100 000.322.101.00.0 000.322.103.00.0 000.322.102.00.0 000.322.103.00.0 640.237.114 TOTAL: 1,472.40 350.50 123.90 342.85 280.35 4.50 2,574.50 • • 1---- ^ 2 City of Tukwila Department o f Community Development velo P ment 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: M10 -132 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/28/2010 Applicant: BAYOU GRILL Issue Date: Receipt No.: R10 -01913 Payment Amount: $85.71 Initials: WER Payment Date: 09/28/2010 01:25 PM User ID: 1655 Balance: $342.85 Payee: .SING - CHYWAN LEE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1461 85.71 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 85.71 Total: $85.71 doc: Receipt-06 Printed: 09 -28 -2010 ' LO -i32- INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd:, #100, Tukwila. WA 98188 • (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Project �t 4.) r Type of Inspection: A u c /Z-o ci 60. -- Address: / � y l � . ' / D ;et: � �g Special Instructions: • L. Date Wanted: �. �- �m� p.m. Requester: Phone No: Approved per applicable codes. • ° Corrections required prior to approval. v COMMENTS: P e�1401-1aA,--nc� Inspect : . � REINSP CTION -FEE REQUIRE Prior Date: r to next inspection. fee must be paid at 6300 Southcenter Blvd:; Suite 100. Call to schedule reinspection. 43 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NQ2 CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 - � I /0/O- /. Project:: / R/7 Vie a P /4-L. Type of Inspection: ic' /n/R fj Address: 2QD/gLL Date Called: Special Instructions: Date Wanted: / 9 _ " p.m. Requester: Phone No: QQ LiApproved per applicable codes. Corrections required prior to approval: COMMENTS: tttli er fi-o,4 De .' .mss 0%ss A- �.. r it i 1 -CAA/ Ali i (o/ - e #) ) (...T1- t`_A. S Insp ctor: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Bliid..-Suite 100. Call to schedule reinspection. • a4 INSPECTION RECORD Retain a copy with permit _ _i _ _ 1 INSPECTION NO. PERMIT NO. . CITY OF TUKWILA BUILDING DIVISION tt. 6300 Southcenter.Blvd., #100, Tukwila. WA 98188 .(206) 431 -3670 Permit Inspection Request Line (206) 431 =2451 • Proj : //,' t I Type o `pAectti�on: jj 1 Q ddress: 7 c [� * Sc- Q JAL t1 { Date Called: _ .� Special Instructions: 7 -, G • _ (� • Date Wanted: tit 1 Lit ,� p.m. Requester: - e? A? SO- -zw-9g-,2,? • E] Approved per applicable codes: • orrections required prior to approval. COMMENTS: , y7 f r re), Q Ate+► , (j . t I,► ° ..-.,i cJ c)'1 9 7 •e o'[ A. l_ _.A., 1 4J ,J ( .. . e,(_.4 . i 440;4" A! 4,. e4 .A 64 0 - 1,.J k.,..fe_ `TO Sfl'6'7' 3 Pie____ AT a P Appzi e --c,- e. , /(-e at Ati- ._ �1 k9 - Du-e-- . i t.ham c v c i-e zll n ector: (Date: r r4 t ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter. Blvd.• Suite 100. Call to schedule reinspection. . INSPECTION NO. INSPECTION RECORD Retain a copy with permit 44. M10- 132. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t• p: ti 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: GA -4th( eoR1t L, Type f Inspection: arcto t4 -. t..1 Address: (o Q OA AI I Date Called: -® "'f /24 Special Inst uctions: 1 . Date Wanted: I (- 2_q �-- 1© Requester: Phone No: -2_6 - 3- 'G- S. 4'7 Approved)fer applicable codes. O Corrections required prior to approval. COMMENTS: 4.44 6 1 -® "'f /24 4 --"' 49,44,Vp F .ti t \ •, - Inspecto Date: SPECTIO FEE REQU RED. Prior t. next inspection. fee must be id at 6300 Southcenter Blvd.. Suite 10 Call to schedule reinspection. " 32 INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: j� f i 1 Type of Inspection: Address: Suite #: F Contact Person: Special Instructions: Phone No.: LI Approved per applicable codes. 1-1 Corntions required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ti7,u�^ ) i✓te.. R f � S Y ./. 1 ff}yyyFg ,y }y 3: � jam., 1* 4 W t;= t P• N� ,. p;;;e Y �4✓ ���`A' ��3 ass i .,� �� P�:- `ie ova? Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: >' „ Date: : Hrs.: 3 .00 REINSPECTION FEE REQUIRED. You will receive an invoice from of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Dc INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Di() - •.9 1"1 /O - /cn? f /0 - - d &" �- /0- 5- SSG PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: ISr ;-ou . C4 , i I T pe of Inspection: -` f Address: 9600 S. r „ it _ L.L- Suite #: -F. c 3—` Contact Person: .c Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ok t 77F�- t ! {fiD HOD ,i1 L i L'/ N.._-. !� O r 0iti '...lc_. l ..'�J.) 1 I, it. .a-'!jy G -1-72 �^ 4.-.; !' ._ ) ) -5 , 4-: n ,-..3 - ; r kv 0? 7.. iF' ?l p* r -.e 54, ,,,A = < < -. , v+ ! t. , ,4 S ( - O iC { ;v. -• 4.6-. - L )..y is , ;J — o F- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 72,.„ C -: -. -, ,)- Date: // ,' -;: ; , Hrs.: 1_ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 = �l & ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION January 19, 2011 Great Sun Corp. 505 S. Lander Street Seattle, WA RE: Final Letter Bayou Grill 633 Southcenter Mall Tukwila, WA To Whom It May Concern: KA No. 066 -10271 Permit No. M10 -132 REr .:;riVED J� r..- 12011 CG AMITY JAN 312011 DEVELOPMENT In accordance with your request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: • Grease Duct Inspection To the best of our knowledge, all work which has been tested and/or inspected has been found to be in general accordance with the approved plans and specifications, engineering revisions, and Chapter 17 of the 2006 International Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Resp = • fully ub 1' ASS t ed, CIATES, INC Jay Operatio s Manager Puyallup CC: City of Tukwila With Offices Serving The Western United States 922 - Valley Avenue NW Suite 101 • Puyallup, WA 98371 • (253) 939 -2500 • Fax: (253) 939 -2556 EAGLE .TEST & BALANCING COMPANY AABC CERTIFIED 815 E. Slain Cushing. OK 74023 Phone: (918) 225 -1668 Fax: (918)25 -1687 13047 S. E. 47th PL. Bellevue. WA 93006 Phone: (425) 747 -9256 Fax: (425) 641 -5662 TEST AND BALANCE REPORT Project: D* 7 ° () GR.( 4—L- Location: 2(vo0 6°ar+14.6J-Ti°R reMLt... /SPAC VG -5 I U Kr.) I L.A , W A °I (6 ie'e Architect: Engineer: A$D55E 1r`) ErJ 6146ERInIC0 i L L G Contractor. W A 51 ! &rO,I 4-1 cA i 'i A) 6 Project Number. • This is to certify that Eagle Test & Balance has balanced the systems described herein to their optimum performance capabilities. The testing and balancing has been performed in accordance with the standard requirements and procedures of the Associated Air Balance Council and the results of these test are herein recorded. Associated Air Balance Council Certification Number. 93 -02-01 Date: Test & Balance Engineer: Stephen D. Barnes Project fli9YD IL GRILL- Date Page of System HP— / AIR DISTRIBUTION TEST SHEET Terminal Number Room Number Terminal Design - - - Test —FPM or CFM - Final Type ,c - . Size Factor FPM CFM • Test 1 Test 2 .Test 3 FPM. . CFM 13 /o " h 0 • :*)s' 1 % 210 .2-/C) 0 /O" 1,0 2C ASO •2gb Zyo _ B )p" ?, o .22C tor ..2.4D Z `fo . 9 23 Jo" /fro 2,2 .25-o 2573 . 2-52) c- )d' 110 .20 145' :mss ?,fig c ,v" 1 O AO 2.17o 2 2.© ,270 R 1 ' - RC- /t • /,D /D5 Ifoc ,)JO5 • l • h • • S Project Name 54Y'IL/e /L L Date,' Page. , of AIR MOVING EQUIPMENT TEST SHEET SYSTEM Equipment Location Area Served Equivmeneeanwracn,rar Model ) Serial Number S7oR E L RR /E i2 4/ 570 l Os?' .28 1.411 tFll1 -Ran Specified Toat CFM - Outlet R/A CFM .fi /A ELBA . . Totat. Static:Pressure {fatat1Ezternaij. joie. lisirre 352) 005 Actual /f 75 /Mg' *-ate or- 9Z Specified Adiral lsi urer ;..0.1R19.733,44/ 1414R/3THo- M0tOTHP.tBHP • l V . Factor Elements - 3' _zoSP ,;2 / %2vr' !, / 5- 209- 209. -2 2.22.2 /.720 >, /S- Remarks , Motor Sheave *NO. Grooves . 330 G v aC VS' „ • S & No. Grooves 4 Fa # 9; )ii J/9 '' Remarks • PE N:L C PY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -132 DATE: 09 -28 -10 PROJECT NAME: BAYOU GRILL SITE ADDRESS: 2600 SOUTHCENTER MALL FC -5 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: t1.- C. l ' 10 Building Division Public Works ❑ IAN� kwc, —L0 ire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 09-30-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route N Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 1 0-28 -10 Approved n Approved with Conditions 12f Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ALLEN & L CONSTRUCTION INC UBI No. 602266279 Phone 2067721506 Status Active Address 12836 65Th Ave So License No. ALLENLC974C1 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 2/21/2003 State WA Expiration Date 2/21/2011 Zip 98178 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ALLENC'995R6 ALLENS CONSTRUCTION Construction Contractor General Unused 3/29/2002 3/29/2004 Re Licensed Business Owner Information Name Role Effective Date Expiration Date CHEN, SHAONA President 02/12/2003 Amount CHEN, SHAONA Secretary 02/12/2003 01cg303743 CHEN, SHAONA Treasurer 02/12/2003 SNOHOMISH CHEN, SHAONA Vice President 02/12/2003 AMERICAN STATES INS CO Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 AMERIAN STATES INS CO 6205105 02/07/2003 Until Cancelled $12,000.00 02/12/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN STATES INS CO 01cg303743 02/07/2010 02/07/2011 07 -2- 04696 -6 GARDEN INVESTMENT GROUP INC SNOHOMISH $1,000,000.0004 /15/2010 2 AMERICAN STATES INS CO 01CG303743 02/07/2004 02/07/2010 $1,000,000.00 01/12/2009 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By 10 -2- 09604 -3KNT CHOI'S PLUMBING InterPlead: No KING Date: 03/10/2010 Amount: $0.00 Bond(s): 6205105 Date: Amount: $0.00 Dismissed Date: Amount: 07 -2- 04696 -6 GARDEN INVESTMENT GROUP INC SNOHOMISH Date: 08/13/2007 • Amount: $0.00 Date. • Amount: $0.00 Dismissed Date: Amount: https : / /fortre s s. wa. gov /lni/bb ip /Print. aspx 10/13/2010 PROJECT INFORMATION PROJECT ADDRESS 2600 SOUTHCENTER MALL FOOD COURT N5 TUKWiLA, WA 98188 -2816 RESTAURANT CONTACT INFORMATION 9421 NE BLUE WAVE COURT BAINBRIDGE ISLAND, WA 95110 CONTACT: MR. CALVIN LEE TEL: (206) 245 -1034 LANDLORD CONTACT INFORMATION WESTFIELD CORPORATION - 633 SOUTHCENTER SEATTLE, WA 98158 -2816 CONTACT: HOWARD DURCHSLAG TEL: (206) 246 -0423 PROJECT ARCHITECT TSE ARCHITECTURE ENGINEERING PLANNING 12930 NE 118TH STREET WOODINViLLE, WASHINGTON, 98012 -5108 TEL: (425) 481 -6601 FAX: (425) 481 -6311 CONTACT: ANDERS REMAN, AiA, PROJECT ARCHITECT DAVID H. WU, PROJECT DESIGNER DURING CONSTRUCTION CONTACT: ANDERS RAMAN, AIA, PROJECT ARCHITECT PARCEL* (PROVIDED 1E3Y OWNER):. 41202470010 ZONING: CONSTRUCTION TYPE: TYPE II—B PROPOSED OCCUPANCY: B ( < 50 OCCUPANTS) OCCUPANT LOAD FACTORS: 200 GROSS (KITCHEN) CODE INFORMATION TUG (TUKWILA URBAN CENTER) OCCUPANT LOAD: PROJECT AREA: TOTAL BUILDING AREA: IMPROVEMENT COST: EXITS: JURISDICTION= PROJECT DESCRIPTION REFER TO SHEET A -2 668 9F (INSIDE WALL MEASUREMENT) 1,700 ,000 SF (APPROXIMATE) $150,000 (ESTIMATED) 1 REQUIRED / 1 PROVIDED CITY OF TUKWILA BUILDING CODES: 200q INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS IGG /ANSI AII7.I -2003 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, WITH STATEWIDE AMENDMENTS 20041 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS 20041 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS 20041 UNIFORM PLUMBING CODE WITH STATEWIDE AMENDMENTS 2006 WASHINGTON STATE ENERGY CODE 2006 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE 2005 NATIONAL ELECTRICAL CODE (NFPA 70) WASHINGTON STATE BARRIER —FREE REQUIREMENTS 4 KING COUNTY RULES AND REGULATIONS, TYP. DRAWING INDEX . TENANT IMPROVEMENT OF AN EXISTING FOOD COURT SPACE WITHIN "WESTFIELD" SOUTHCENTER MALL. PROPOSED USE: "BAYOU GRILL" FOOD ESTABLISHMENT. 2. WORK INCLUDES KITCHEN 4 SERVICE COUNTER AREA. 3. THIS PERMIT DOE-9 NOT INCLUDE PLUMBING (RPBA), ELECTRICAL, GAS, MECHANICAL, TYPE I HOOD SUPPRESSION SYSTEM (UL300 SYSTEM), OR SIGNAGE. THESE PERMITS SHALL BE APPLIED FOR BY SUBCONTRACTOR AFTER BUILDING PERMIT HAS BEEN APPROVED. v MAP sour 4 Vb�R ABBREVIATIONS A —I KEY PLAN, PROJECT INFO, PROJECT DESCRIPTION, NOTES, 4 VICINITY MAP A -2 FLOOR PLAN, SCHEDULE-5, 4 NOTES A -3 REFLECTED CEILING PLAN, 4 DETAILS HEALTH DEPARTMENT NOTES I THE HEALTH DISTRICT OPERATING PERMIT APPLICATION PROCESS MUST BE COMPLETED PRIOR TO OPENING FOR BUSINESS 2. AN INDIRECT WASTE 19 REQUIRED FOR THE FOOD PREPARATION SINKS, THREE — COMPARTMENT SINK, ICE MACHINE, REFRIGERATOR, AND ANY EQUIPMENT IN WHICH FOOD 15 PLACED. 3. A HORIZONTAL SEPARATION OF AT LEAST 16 INCHES OR A VERTICAL PARTITION 16" IN HEIGHT 19 REQUIRED BETWEEN THE FOOD PREPARATION SINK AND ALL SOURCES OF CONTAMINATION. 4. A HORIZONTAL SEPARATION OF AT LEAST 16 INCHES OR A VERTICAL PARTITION 16" IN HEIGHT i5 REQUIRED BETWEEN THE HAND WASH SINKS AND ALL FOOD PREPARATION AREAS AND COUNTERS. 5. WATER HEATERS MUST BE OF SUFFICIENT SIZE TO PROVIDE HOT WATER TO DISHWASHER AND /OR SCULLERY SINKS AND AT THE SAME TIME PROVIDE HOT WATER TO ALL HAND WASH SINKS. 6. HOT WATER MUST BE AVAILABLE TO ALL HAND WASH SINKS WITHIN 15 SECONDS. 7. EXTRA WALL PROTECTION 15 REQUIRED ON WALLS BEHIND SINKS, INCLUDING RESTROOM AND SERVICE AREA HAND YVASH SINKS, AND FOOD PREPARATION TABLES. A 16 —INCH HIGH BAGKSPLASH OF PLASTIC LAMINATE, FIBERGLASS — REINFORCED PLASTIC. OR EQUAL IS AGGGEPTABLE. WALL PROTECTION BEHIND MOP SINKS MUST DOVER THE ENTIRE SPLASH ZONE. PLASTIC COATED HARDBOARD IS NOT ACCEPTABLE. 8. THE FLOOR MUST BE SURFACED WITH A DURABLE, NONABSORBENT, EASILY GLEANABLE MATERIAL q. THE CEILING ABOVE THE FOOD PREPARATION AREAS MUST BE NONABSORBENT, NON — PERFORATED, SMOOTH, AND EASILY GLEANABLE. 10. ALL LIGHT FIXTURES IN FOOD PREPARATION AND STORAGE AREAS MUST BE PROVIDED WITH COVERS OR SHATTERPROOF BULBS. II. PLUMBING MUST MEET STATE AND LOCAL CODES. 12. THE VENTILATION SYSTEM SHALL BE INSTALLED AND OPERATED TO MEET APPLICABLE BUILDING, MECHANICAL, AND FIRE CODES. A PRE —OPERATIONAL INSPECTION IS REQUIRED PRIOR TO OPENING FOR BUSINESS. AT THE TIME OF INSPECTION THE CONSTRUCTION OF THE FOOD SERVICE ESTABLISHMENT MUST BE COMPLETE AND ALL EQUIPMENT MUST BE IN PLACE. INCOMPLETE CONSTRUCTION MAY RESULT IN A REINSPECTION FEE. CONTACT THE FOOD PROGRAM OFFICE A MINIMUM OF ONE WEEK IN ADVANCE TO SCHEDULE AN APPOINTMENT. THIS WILL ENSURE COMPLIANCE WITH THE RULES AND REGULATIONS OF THE STATE BOARD OF HEALTH FOR FOOD SERVICE SANITATION. MENU DEPARTMENT REV114 No changes shall lelmade to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical gIectrtcai gas as Piping City of Tukwila BUILDING DIVISION FILE C Plf Permit No. t4 10—‘431 Plan review approval is subject to errors and omissions. kpproval of construction documents does not authorize :o!':ation of any adopted cod • or ordinance. Receipt ti.pproved Field Cop n •''ons is acknowledged: By Date: — o City Of Tukwila BUILDING DIVISION ACT ADJ. APP. ACOUSTICAL CLG TILE ADJUSTABLE ABOVE FINISHED FLOOR BLK'G BLOCKING L. LAVATORY L.F. LINEAR FOOT/FEET SLADE C.L. CLR CLG CMU COL. CONC. CONT. CONST. clot CENTERLINE CLEAR/CLEARANCE CEILING CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CONSTRUCTION CARPET MIL. METAL MAT'L MATERIAL MFR MANUFACTURER MECH. MECHANICAL MIN. MINIMUM MR MOISTURE RESISTANT N/A NOT APPLICABLE N.I.C. NOT iN CONTRACT NO NUMBER NTS NOT TO SCALE DET DETAIL DIM DIMENSION DWG DRAWING O.A. OC. 0.1-1. OVERALL ON CENTER OVERHANG ELEC. ELECTRICAL EQ EQUAL LEGEND SECTION EXISTING CONDITION TO REMAIN NEW CONSTRUCTION CONSTRUCTION TO BE DEMOLISHED EXHAUST FAN ROOM SYMBOL DOOR SYMBOL FIRE EXTINGUISHER EXIT SIGN a 50 CFM 00l EXIT F.A.R. FLOOR AREA RATIO F.E. FIRE EXTINGUISHER F.F. FINISHED FLOOR FF.4E. FIXTURES, FURNISHINGS, 4 EQUIPMENT FA.iC. FURN. BY OWNER INSTALLED BY CONTRACTOR F O.I:O. FURN. BY OWNER INSTALLED BY OWNER FRP FIRE RATED PANEL FT FOOT/FEET FURN FURNISH F.V. FIELD vERIFY GA GC. GWB HDWR. HM HT IN INSt. INSUL. GAUGE GENERAL CONTRACTOR GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT INCH INSTALL INSULATION GENERAL NOTES P —LAM PLASTIC LAMINATE P.L. PROPERTY LINE PT PRESSURE TREATED PTO PAINTED RCP REFLECTED CEILING PLAN REF. REFRIGERATOR REINF REINFORCING/ REINFORCEMENT REQ'D REQUIRED REV REViSED/REViSION SCHED SCHEDULE SD. SF. S.G. SIM S.O.G. SUSP Sv SMOKE DETECTOR OQUARE FOOT/FEET SAFETY GLASS SIMILAR SLAB ON GRADE SQUARE SUSPENDED SHEET VINYL TEMP TEMPERED T.O. TOP OF TYP. TYPICAL UAN. UNLESS OTHERWISE NOTED VCT VINYL COMPOSITION TiLE VTO VENT TO OUTSIDE I. THIS SET RESENTS "THE PERMIT DRAWINGS" AND 15 INTENDED TO SHOW MINIMUM REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CONSTRUCTION NECESSARY FOR THE COMPLETE INSTALLATION OF ALL OPERATING SYSTEMS, MATERIALS AND FINISHES IN ACCORDANCE WITH MFR.'S RECOMMENDATION. CONTRACTOR SHALL THOROUGHLY REVIEW DRAWINGS, SPECIFICATIONS AND OWNER'S REQUIREMENTS. 2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS PRIOR TO BID. DISCREPANCIES IN DIMENSIONS, DRAWINGS, GRAPHIC REPRESENTATION AND ACTUAL FIELD MEASUREMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. 3. CONSTRUCTION SHALL BE BASED ON THE LOCAL JURISDICTION APPROVED PLANS AND OWNER'S COMMENTS. THE APPROVED PLANS ARE TO REMAIN ON SITE AT ALL TIMES FOR USE BY ALL INVOLVED TRADES AND INSPECTORS. 4. THIS SET OF DRAWINGS SHALL NOT BE COPIED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN CONSENT FROM THE OWNER. THIS DOCUMENT 15 CONSIDERED AS ONE UNIT AND SHALL NOT BE CONSIDERED COMPLETE OR WHOLE IF DOCUMENTS ARE SEPARATED IN ANY MANNER. DOCUMENTS SHALL NOT BE SEPARATED FOR THE PURPOSES OF SUBMITTING PROPOSALS OR FOR SEPARATE PHASES OF CONSTRUCTION. 5. THESE DOCUMENTS ARE PREPARED FOR USE BY THE CONTRACTOR AND IN NO WAY, EITHER IN WHOLE OR IN PART CONSTITUTE ANY DIRECTION OR INSTRUCTION TO ANY CONTRACTOR WITH REGARD TO CONSTRUCTION METHODS, MEANS OR TECHNIQUES. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION WORK INCLUDING, BUT NOT LIMITED TO, SEQUENCE 4 TEMPORARY SHORING OF ALL EXISTING STRUCTURES 4 VERIFICATION OF EXISTING UTILITIES 4 SERVICES. 7. CONTRACTOR SHALL NOTIFY UTILITIES PRIOR TO COMMENCEMENT OF ALL WORK. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS, SUBJECT TO LOCAL JURISDICTION AND UTILITY INSPECTOR'S FINAL APPROVAL. S. CONTRACTOR SHALL GLEAN UP ALL PUBLIC RIGHT —OF —WAY AND PRIVATE DRIVEWAYS AFTER EACH WORK DAY. CONSTRUCTION VEHICLES SHALL NOT BLOCK PUBLIC TRAFFIC OR ENTRIES AT ANY TIME. CONTRACTOR SHALL WORK ACCORDING TO LOCAL JURISDICTION'S ALLOWED SCHEDULES ONLY. q. ALL WORK SHALL COMPLY TO I.B.G. 200x, WASHINGTON STATE ENERGY CODE, LOCAL JURISDICTION ZONING 4 BUILDING CODES, REGULATIONS, 4 REQUIREMENTS, LATEST AMENDMENTS (TYPICAL), 4 KING COUNTY HEALTH DEPARTMENT. BAYOU HURRICANE CHICKEN BAYOU TROPICAL CHICKEN BLACKENED FISH BOURBON CHICKEN CAJUN SAUSAGE CAJUN SPICY CHICKEN CHICKEN ETOUFFEE CRAWFISH BOIL CRAWFISH ETOUFFEE CRAWFISH OVER FETTUGGINI PASTA DIRTY RICE RED BEANS 4 RICE SEAFOOD GUMBO SHRIMP, CHICKEN, 4 SAUSAGE JAMBALAYA SHRIMP CREOLE SHRIMP JAMBALAYA (CHOICE OF VEGETABLES) CAJUN SPICY CHIPS CORN MIXED VEGETABLES 7:11EfL JCPenney REVIEWED FOR CODE COMPLIANCE OCT APPROIMP aTr 2010 City of Tukwila BUILDING DIVISION FROJEGT AREA 668 S.F. KEY PLAN SCALE: IN — 100' —O' cirroFTVAwi° u+ SEP 2 8 2010 PERMIT CENTER — TsE ARCHITECTURE ENGINEERING PLANNING 12930 N.E. 178th STREET Woodinville, WA 98072 -5708 (425) 481 -6601 A FAX: 481 -6371 6 :8 REGISTERED 41 1 r 1 ITECT AND • R.RAMAN STATE OF WASHINGTON PERMIT SET project title: BAYOU GRILL 2600 SOUTHCENTER MALL FOOD COURT #:5 TUKWILA, WA x8188 -2816 sheet title: KEY PLAN, PROJECT INFO PROJECT DESCRIPTION, NOTES 4 VICINITY MAP revisions: designer: DWI drawn: MI5 checked: ARR date: a /I /10 scale: 1" = 100' -O" file: '7014 -A att: file: sheet #: A________ 1 . HOOD N❑ TAG MODEL LENGTH MAX. CD ❑KING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD C ❑NSTRUCTI ❑N HOOD CONFIG, TOTAL EXH, CFM RISERS) TOTAL SUP, CFM RISERS) END T❑ END ROW WIDTH LENG. DIA. CFM • S.P. WIDTH LENG. DIA, CFM S.P. 1 LEFT 5430 ND -2 9' 0.00' 600 Deg 2475 10' 23' INSULATION FOR BACK STANDOFF 2475 - 0.916' 0 517 LBS 3 20' 20' 2 304 SS Where Exposed LEFT ALONE 16' 3 Incandescent Light Fixt NO APPROVED FILTER TYPES: ALUM, BAFFLE, SS BAFFLE, HE SS BAFFLE, SPARK ARRESTOR BAFFLE, CAPTRATE (2 STAGE), AND HV CARTRIDGE 2 RIGHT 5430 ND -2 9' 0.00' 600 Deg, 2475 10' 23' 2475 - 0,916' 0 304 SS Where Exposed RIGHT ALONE ilVVL HDDD NO. ii\i V4.Y1.1l1ii V1• FILTER(S) LIGHTS) UTILITY CABINET(S) FIRE SYSTEMHANGING PIPING HOOD WGHT TYPE QTY. HEIGHT LENGTH QTY. TYPE WIRE GUARD LOCATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY LOCATION 1 Captrate Solo Filter wi 3 20' 16' 3 Incandescent Light Fixt NO Wall Mnt Ansul R102 3.0/3.0/3.0 INSULATION FOR BACK STANDOFF . 33' -48' YES 517 LBS 3 20' 20' 2 Captrate Soto Filter wi 39'-78' 20' 16' 3 Incandescent Light Fixt NO APPROVED FILTER TYPES: ALUM, BAFFLE, SS BAFFLE, HE SS BAFFLE, SPARK ARRESTOR BAFFLE, CAPTRATE (2 STAGE), AND HV CARTRIDGE YES LBS 3 20' 20' HOOD NO, OPTION MIN. EXH. CFM /FT MAX. MAU. CFM /FT LENGTH RANGE MAX. LEN. FOR 1 RISER WIDTH RANGE WIDTH INCR. 1 LEFT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 304 SS - INSULATION FOR BACK STANDOFF . 39' -78' 1' 8' 6' 33' -48' 2 RIGHT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 304 SS 1' INSULATION FOR BACK STANDOFF . 33' -48' 11,5' -48' 700 DEG. 250 CFM /FT ETL RATINGS (PER UL 710): FILE # 3054804 -001 MAX. TEMP, MIN. EXH. CFM /FT MAX. MAU. CFM /FT LENGTH RANGE MAX. LEN. FOR 1 RISER WIDTH RANGE WIDTH INCR. SIDE OVERHANG FRONT OVERHANG VERT. CLEARANCE (WITH LIGHTS) VERT. CLEARANCE (W /❑ LIGHTS) MODEL: ND & ND2 (WITH & W/O PSP) 450 DEG. 150 CFM /FT - 3' -16' 16' 39' -78' 1' 8' 6' 33' -48' 11.5' -48' 600 DEG. 200 CFM /FT - 3' -16' 16' 39' -78' 1' 6' 6' 33' -48' 11,5' -48' 700 DEG. 250 CFM /FT - 3' -16' 16' 39'-78' 1' 6' 6' 33' -48' 11.5' -48' APPROVED FILTER TYPES: ALUM, BAFFLE, SS BAFFLE, HE SS BAFFLE, SPARK ARRESTOR BAFFLE, CAPTRATE (2 STAGE), AND HV CARTRIDGE PERFORMANCE: ND & ND2 (WITH & W/O PSP) MAX, AVG, C❑ ❑KING SURFACE TEMPERATURE (DEG. F) / COOKING SURFACES CONFIGURATION MIN. EXHAUST CFM /FT SUGGESTED SUPPLY CFM /FT. VIA FRONT SUPPLY PLENUM 450 DEG. - OVENS, STEAMERS, KETTLES, OPEN-BURNER RANGES GRIDDLES, AND FRYERS WALL HOOD 150 120 2 PIECE ISLAND BACK TO BACK WALL HOODS 300 240 9' 600 DEG.-GAS CHARBROILERS ELECTRIC CHARBROILERS, AND WOKS WALL HOOD 200 160 2 PIECE ISLAND BACK TO BACK WALL HOODS 400 320 700 DEG.- MESQUITE GRILLS CHARCOAL CHARBROILERS GAS CONVEYOR CHARBROILERS WALL HOOD 250 200 2 PIECE ISLAND BACK TO BACK WALL HOODS 500 400 U.L. Listed Incandescent Fixture -High Temp Assembly xSUPPLY CFM /FT CONSULT FACTORY REPRESENTIVE IF HIGHER VALUES ARE REQUIRED 100 F. 70 z 40 0 w 20 50 30 w I'II.TER COLLECTION EFFICIENCY 2" Captxat ?Gxcasc-Stop Solo Filter 0411u \\I% 0.1 PARTICLE DIAMETER (tun) 10 RLSISTANCB (in. H20) RESISTAlNCE VS. AIRFLOW - 2" :aptxat ?Gxcasc-Stop Solo Filter 46 1.4 12 08 a6 04 na 300 400 600 AIRFLOW (cfin) 1000 AGENT LINE DUCT PROTECTION NOZZLE DETECTORS DETECTION LINE ...0° r PLENUM PROTECTION NOZZLE EXHAUST RISER HANGING ANGLE 20' CAPTRATE SOLO FILTER WITH HOOK 1' LAYER OF INSULATION FACTORY INSTALLED IN 3' INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP LEFT QUARTER END PANEL 1 SYSTEM CONTROL AUTOMAN WITH AGENT TANK ENCLOSED REMOTE MANUAL PULL STATION TYPICAL ANSUL R102 SYSTEM LAYOUT WITH REMOTE MOUNTED AUTOMAN 3' 54' SPECIFICATI ❑NI CAPTRATE GREASE —STOP. SOLO FILTER THE CAPTRATE GREASE-STOP SOLO FILTER. IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S- BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TD DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS CONSTRUCTED OF 430 STAINLESS STEEL, AND SIZED TO FIT INTO STANDARD 2 -INCH DEEP HOOD CHANNEL(S), UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 90% GREASE PARTICLES SEVEN MICR ❑NS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. INCANDESCENT LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) CTION VIEW — MODEL 5430ND -2 110' ND -2 Series Specification The ND -2 series hood is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction shall be type 304 stainless steel with a #3 or #4 polish where exposed. Individual component construction shalt be determined by the manufacturer and ETL. Construction shall be dependent on the structural application to minimize distortion and other defects. All seams, joints and penetrations of the hood enclosure to the lower outermost perimeter that directs and captures grease -laden vapor and exhaust gases shall have a liquid -tight continuous external weld in accordance with NFPA 96. Hood shall be wall type with fully welded 10 gauge corner hanging angles. Corner hanging angles have a .625 x 1.500 slot pre - punched at the factory, allowing hanging rods to be used for quick and safe installations, Hanging rod and connection is provided by and installed by others, Ventilator shall be furnished with U.L. classified captrate solo filters, supplied In size and quantity as required by ventilator, The filters shall extend the full length of the hood and the filler panels shall not be more than 6' in width, The hood manufacturer shall supply complete computer generated submittal drawings including hood section view(s) and hood plan view(s). These drawings must be available to the engineer, architect and owner for their use in construction, operation and maintenance. Exhaust duct collar to be 4' high with 1' flange, Duct sizes, CFM and static pressure requirements shall be as shown on drawings. Static pressure requirements shall be precise and accurateJ air velocity and volume Information shall be accurate within 1 -ft increments along the length of' the ventilator. U.L. Incandescent tight fixtures and globes shall be installed and pre -wired to a junction box, The light fixtures shalt be installed with a maximum of 4'0' spacing on center and allow up to a 100 watt standard light bulb. The hood shall have: - A double wall insulated front to eliminate condensation and increase rigidity. The insulation shall have a flexural modulus of 475 EI, meet UL 181 requirements and be in accordance with NFPA 90A and 90B. - An integral front baffle to direct grease laden vapors toward the exhaust filter bank, - A built -in wiring chase provided for outlets and electrical controls on the hood face and shall not penetrate the capture area or require an external chaseway. - A removable grease cup for easy cleaning, The hood shall be ETL Listed as 'Exhaust Hood Without Exhaust Damper', ETL Sanitation Listed and built in accordance with NFPA 96. The hood shall be listed for 450 °F cooking surfaces at 150 CFM /ft, 600 °F cooking surfaces at 200 CFM /ft, and 700 °F cooking surfaces at 250 CFM /ft. 1 1 W �— 10' 9' 1 Q Q 9' Q 17 10• U.L. Listed Incandescent Fixture-High Temp Assembly 23' U.L. Listed Incandescent Fixture -High Temp Assembly 23' Light f Light l . 0 N. O 54' 9' 0.00'Nom. /9' 0.00'OD 54' 54' PLAN VIEW — Hood #1 (LEFT) 9' 0.00" LONG 5430ND -2 9' 0.00'Nom. /9' 0.00'OD 54' 1 3' 1 54' F iEVIt L)10' _- 0c DE COMPLIANCE OCT 0 7 2010 PLAN VIEW — Hood #2 (RIGHT) 9' 0.00" LONG 5430ND -2 MID - I32 City ©t Tukwila BUILD: .IS nwisiON CITYOFTUKIMLA SEP 2 8 2010 PERMIT CENTER REVISIONS DESCRIPTION DATE: 0 A D 1 c SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com L Cu 0.1 4-> u 0 LJ 0 O DATE: 9/1/2010 DWG. #: 1209916 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET NO 1 FAN ..._.r .... _ ..__. _-.- -- _- .-- - - - - -- TEMP. RISE REQUIRED INPUT GAS PRESSURE GAS TYPE 3 252837 232610 55 deg F 7 in, w.c, - 14 in. w.c. Natural UNIT FAN UNIT MODEL # MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) N❑. WEIGHT (LBS.). N❑. 1 - Low Fire Start 1 - Manifold Pressure Gauge, -5 to 15' we 1 NCA16FA NCA16FA 3 2475 1,150 1017 1.000 3 208 3.3 157.45 2 NCA16FA NCA16FA 828.05 2475 1.150 1017 1.000 3 208 3,3 157.45 ......-- -_.-v FAN ..._.r .... _ ..__. _-.- -- _- .-- - - - - -- TEMP. RISE REQUIRED INPUT GAS PRESSURE GAS TYPE 3 252837 232610 55 deg F 7 in, w.c, - 14 in. w.c. Natural 2 UNIT FAN UNIT MODEL # BLOWER H ❑USING TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS.). N❑. 1 - Low Fire Start 1 - Manifold Pressure Gauge, -5 to 15' we 1 - Motorized Backdraft Damper for A2 -D Housing 3 A2- D.500 -G15 G15 A2 -D.500 - Three Phase Only 3960 0.625 939 3.000 3 208 9.5 828.05 FAN UNIT NO, INPUT BTUs OUTPUT BTUs TEMP. RISE REQUIRED INPUT GAS PRESSURE GAS TYPE 3 252837 232610 55 deg F 7 in, w.c, - 14 in. w.c. Natural FAN UNIT N❑. OPTION (Qty. - Descr.) ITEM SIZE 1 1 - Grease Box 1. # 1 Curb 1 - Extra Set of Belts Vented Hinged 2 1 - Grease Box Curb 26.500'W x 26,500'L x 20,000'H Vented 1 - Extra Set of Betts 3 # 3 3 1 - Inlet Pressure Gauge, 0 -35' Insulated 1 - AC Interlock Relay - 24VAC Coil 1 - Low Fire Start 1 - Manifold Pressure Gauge, -5 to 15' we 1 - Motorized Backdraft Damper for A2 -D Housing 1 - Separate 120V Wiring Package (Required for EMS or Prewire with VFD) - Three Phase Only NO. FAN ITEM SIZE 1. # 1 Curb 26.500'W x 26,500 "L x 20,000'H Vented Hinged 2 # 2 Curb 26.500'W x 26,500'L x 20,000'H Vented Hinged 3 # 3 Curb 31,000'W x 79,000'L x 20,000'H Insulated FAN #3 A2- D.500 -G15 - HEATER 1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 15' BLOWER 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. GAS PRESSURE GAUGE, 0 -35', 2.5' DIAMETER, 1/4' THREAD SIZE 5. CO ❑LING INTERLOCK RELAY. 24VAC COIL. 120V CONTACTS. LOCKS OUT BURNER CIRCUIT WHEN AC IS ENERGIZED. 6. LOW FIRE START. ALLOWS THE BURNER CIRCUIT TO ENERGIZE WHEN THE MODULATION CONTROL IS IN A LOW FIRE POSITION. 7. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5' DIAMETER, 1/4' THREAD SIZE 8. MOTORIZED BACK DRAFT DAMPER 22.75' X 24' FOR SIZE 2 STANDARD & MODULAR DIRECT FIRED HEATERS W /EXTENDED SHAFT, STANDARD GALVANIZED CONSTRUCTION, 3/4' REAR FLANGE, LF120S ACTUATOR INCLUDED 9. SEPARATE 120VAC WIRING PACKAGE FOR MAKE -UP AIR UNITS. OPTI ❑N MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH EMS PACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM EMS TO MUA SWITCH. 8 5/16' CURB OUTER WALL DISCHARGE OPENING 18 3/4' 6 1/8' L_ 16' SUPPLY SIDE HEATER INFORMATION' WINTER TEMPERATURE = 20•F. TEMP. RISE = 55•F. OUTPUT BTUs AT ALTITUDE OF 0.0 ft. = 232610 INPUT BTUs AT ALTITUDE OF 0.0 ft. = 252837 —0 0 0 AIRFLOW 1 FLEX CONDUIT FOR FIELD WIRING a 3 FAN #1 NCA16FA - EXHAUST FAN 39 3/8 33 3/4 22 5/8 16 1/2 19 1/2 24 28 39 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FAN #2 NCA16FA - EXHAUST FAN 39 3/8 33 3/4 f 22 5/8 16 1/2 19 1/2 24 28 39 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) LIFTING LUG 3 3/4' ,1 20' EQUIPMENT CURB 37 3/8' 00 31' FEATURES' - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300•F <149•C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 3001F (149•C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600•F (316•C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. ❑PTI ❑NS GREASE BOX EXTRA SET OF BELTS FEATURES' - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300•F (149•C) - GREASE CLASSIFICATION TESTING 20 16 1/4' ROOF OPENING 2' SMALLER THEN CURB DIMENSION. NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300T (149•C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600•F (316•C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS GREASE BOX EXTRA SET OF BELTS 36 3/4' 16 1/4' 1 26 1/2' 26 1/2' 20' 24 VENTED CURB 20 GAUGE STEEL CONSTRUCTI ❑N 3' FLANGE 26 1/2' ROOF OPENING DIMENSI ❑NS VENTED CURB 20 GAUGE STEEL CONSTRUCTION 3' FLANGE 40 1/8' \ 24 24 �/ ROOF OPENING DIMENSIONS P1(O 13Z 135 7/8' 42 1/8' 1 • AIRFL ❑W SERVICE DISCONNECT SWITCH BLOWER /MOTOR ACCESS DOOR 24' SERVICE CLEARANCE REQ. DIRECT FIRED MODULE 39 9/16' CI0 1' NPT O • O 0 7 13/16' — AIRFL ❑W 79' i E C MPUANC[. rtr_ ti't EJ,J city of Tukwila J:!NG DIVISION RECEIV U CITY OF TULA SEP 2 8 2010 PERMIT CENTER REVISIONS DESCRIPTION DATE: A A 0 0 11"1" II !HI I ik 142 Nft 1Nft SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com Grill- Sou±hcen±er DATE: 9/1/2010 DOiiYG #: 1209916 DRAWN SCALE: 1/16 MASTER DRAWING S:: EET MO. 2 L LlJV NO, 11 Y1 TAG VL 1L L. 11 V PACKAGE i LL i V LJ I-/ LOCATION SWITCHES ROOFTOP STARTERS OPTION FANS CONTROLLED LOCATION QUANTITY TYPE CLOSED H.P. VOLT FLA 1 EMS21183 Wall Mount In SS Box SS Wall Mount Box 1 Light 1 Fan 1 Other EMS 831 Exhaust in Fire, Lights out in Fire Exhaust 3 1.000 208 3,3 Exhaust 3 1.000 208 3.3 Supply 3 3,000 208 9,5 SECURE TO WALL WITH 4 SCREWS TEMPERATURE SWITCH FAN AND LIGHT CONTROL PANEL WALL MOUNTED ENERGY MANAGEMENT SYSTEM MODULATING EMS INSTALLATIIB NAME Bayou Grill— Southcenter DRAWING NUMBER EMS21183- 1209918 - #1 -1 1 JOB NUMBER DATE 1209916 MODEL 9/1/2010 EMS21183 HOOD TO CONTROL PANEL GN 4 EMS CONTROL PANEL - GROUND -® B (No Lights out m IS (Lights out in fire) 5 6 7 POWER FEED FOR CONTROLS AND LIGHTING BREAKER PANEL NTROL 20V 15A B EMS CONTROL PANEL OM- HEATED MAKE —UP AIR* ITerrn 7 ) connect ct -® • DO NOT WIRE WHEN IBT WRATP R 8 9 10 DDC, BUILDING MANAGEMENT OR RTU INTERFACE CONTROL PANEL DRY CONTACTS ON /OFF WITH FAN RUNNING 0 -10VDC SIGNAL cl PROPORTIONAL TO SPEED C yc1 �10 1 RC11 NC 1RC21 D5 DDC, BUS or RTU TEMPERATURE SENSOR WIRING OF FIELD INSTALLED) CONTROL PANEL SN -2 SN -3 - -BK - --1 S4 1 - -� - --I S5 1 -- $- H- - S6 1 - -BD - - --I S7 1 BR -1 S9 S8 1 11. FIRE SYSTEM MICROSWITCH 120VAC SHUNT TRIP WIRING TO CONTROL PANEL BREAKER WIRING 12 ANSUL OR PYROCHEM FIRE SYSTEM BL 13 MICROSWPPiAgE -- B -- FIRE __ RP__ RELAY CONTACTS MS -1 BR -® CONTROL PANEL SHUNT _vlai NEUTRAL Mil- - --I 14 15 C2 NOTE2: IF NO FIRE SYSTEM ON HOOD, JUMPER C1 AND ARL TOGETHER HOTEL: BUILDING FIRE ALARM IS TO BE WIRED TO THE "ALARM INITIATING SWITCH" INSIDE THE FIRE SYSTEM AUTOMAN MICRO — SWITCHES WIRING WHEN MULTIPLE FIRE SYSTEMS CONNECTED TO ONE EMS PANEL (3 SHOWN HERE) F9 #1 NORMALLY OED I NORMALLY OPEN Z _ L COMMON NORMALLY CLOSE s #2 NORMALLY OPEN L COMMON 1 NORMALLY CLOSE FS #3 NORMALLY OPEN L COMMON CONTROL PANEL 16 17 18 19 20 21 22 23 24 FAN WIRING TO CONTROL PANr,I1 FAN BREAKER PANEL, SEE DRAWING MOTOR TABLE FOR BREAKER SIZING 1- k 1- k 15.91 4 , r.,..., ir SUPPLY .111 -{ IN SUPPLY VFD #1 j INVERTER DUTY I - MOTOR EXHAUST Ptati - INVERTER DUTY MOTOR IA VFD #2 EXHAUST --I TO EXHAUST #3 VFD #3 — - INVERTER DUTY MOTOR Separate Steel Conduits 3 PHASE 208/460/575 VOLT 1 PHASE 208/220 VOLT INPUT TO L1 & 12 TERMINALS ELECTRIC GAS VALVE WITH RESET RELAY r MANUAL RESET RELAY -- (INSTACUMCBY YPPLUMBEER) CONTROL PANEL NOTES - - - -- DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YV - YELLOW EL - BLUE GY - GRAY BR - BROWN OR - ORANGE RD - RED WH - WHITE GN - GREEN PR - PURPLE OR /BL - ORANGE /BLUE (STRIPE) BL /RD - BLUE/RED (STRIPE) RD /GN - RED /GREEN J (STRIPE) HOOD LIGHTS 18' WALL MOUNTED EMS SYSTEM 20' TOME SVITCFS DERGT MMIMGENDIT SYSTEM r Min Inn PUSH 9UTTIIN OVERIDE SWITCH r ENERGY MANAGEMENT SYSTEt11JOB NAME Bayou Grill— Southcenter DRAWING NUMBER EMS21183- 1209916 — #1 -2 1JOB NUMBER DATE 9/1/2010 1209916 MODEL EMS21183 120VAC c 1 ego BREAKER • 14 A 2 16 AV' 1:•:` C8 -01 (5 Amp) DO NOT CONNECT TO SHUNT TRIP BREAKER 3 4 5 6 7 B 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PG. 1 1c1 22�t RC NO 10ResrM H000 LiGHT$MAX 1000)A, Y� S LT-01 PR -01 i K 1 OR II-OI 0 4 RK �( AOa -01 RE -03_ D YED BK-7203 4.,'..5Y C YW I T TC-02 ipQ -1417 Yw TC -03 4311_&4 1.7 YW C11ig RE -09 -1 WH PANEL COOLNG FAN WIRE HEATED M% 1 1 t T tafornIBT indirect Fired HeotersJ- Hood t)ght Swltdtax 1000 Exhaust On In Fos Lights Out In Fire List F'ONENT tOENnFlCAlION Locollaa IC9-01 Craft Breaker 1 L489 (5 Amp) [1] ILT-01 "FOYER ,eiga" t- 1052C 5 LT-02 - 03'1 0 U {/t-1 05 205 IPe o PPuueh Button Override-07-MM IRE-01 Fire DPDT Relay- 34.110.014&0 RE -02 Fee DPDT Relay- 34.110.0148.0 RE- 03T1ner/Pueh Button Relay- 34.110.0146.0 IRE -Wan ON Relay- 34.110.014&0 [5128] IRE -15RrM ROdoyRDTRelelaay-344.1 0.1 0146.0 (9 3 S I-01 y&&4 Speed Cmirol -SMV SERIES SH -03Esh Speed CContrtrol-d -SAW SERIES sN- )D(retrperature Senor - A/100- 3w -P0-4' SW-0l ran On Auto Switch- 82.40:8295.9E SW- 0211ood t Switdr82.40.52959E TC-)IXT Cantrdler -P10i3 w\ON Rol 11-01 1 Override Timer (30 Minutes) -R27 -ESA 32 31 38-38 "TEMPERATURE SENSOR(S) MAY NEED TO BE FIELD INSTALLED AND SIRED TO PA/EL" . .a:1 18in. x 24in. x 8.6in. Box SPARE RELAY CONTACTS Spore relay contacts can be used to control items requiring that down when the fire system discharges, such as shunt trips„ &grids, etc. NO NC COL COI( 8 7 615 SOCKET STYLE 'COON' =ENO - D No- C°ntaic: ON and NO-BL C -RD OFF with Exhaust C-RD -RD (o amps mall) - - -- FIELD WIRING INTERNAL WRING Inril TERMINAL IN PANEL MI TERMINAL IN PANEL AND REMOTE Drawing shown De- energized. RRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE OR/BL - ORANGE/BLUE W1l - EBLL/RDE, BLUE/RED PR - PARK E Ho /GN � RED /GREEN (STRIPFI DIDICATD.N LIMITS Modell EMS Series Certifications) Controls shall be listed by ETL CUL 508A). Applications The Energy Management System (EMS) is capable of saving energy during idle cooking periods. The EMS is designed to automatically reduce exhaust and supply airflow quantities while ensuring hood performance is maintained, The EMS uses high and low speeds that shall be adjusted by variable frequency drives. A temperature switch in the exhaust duct shall control airflow set points and modulate the fans during cooking operation to maximize energy savings. A 1007 airflow override button shall be supplied with an adjustable timer. Construction: The control interface shall include (1) fan switch, (1) hood light switch, (1) 100% airflow override push button and indicator lights. Indicator lights shall include a 'power' light, a 'fans on' light, and a '100% airflow override' light. The control interface shall be screen printed on stainless steel and be able to be installed on the face of the hood, face of' the utility cabinet, or on the face of the control enclosure, The control enclosure shall be NEMA 1 rated and listed for installation inside of the exhaust hood utility cabinet. The control enclosure may be constructed of stainless steel or painted steel. Variable frequency drives shall allow full adjustment of high speed and low speed airflows for proper kitchen balance. Drives shall contain motor thermal overload protection and control inputs for up to 7 preset speeds. Acceleration and deceleration times shall be fully adjustable as well as fan speed at each of' the 7 different inputs. Drives shall also allow for a minimum and maximum frequency set - point. Drives are capable of' controlling up to 5 HP each, Adjustable temperature switch shall be mounted in the exhaust hood riser. Temperature probe shall be constructed of Stainless Steel. Temperature switch shall be factory set at 130 °F for 600 °F cooking applications and 90 °F for 400 °F cooking applications. The temperature sensor is fully modulating and adjusts on temperature changes. The riser mounted temperature sensor constantly monitors the exhaust air temperature and works in conjunction with a panel mounted temperature controller to modulate the system based on the temperature, therefore maximizing energy savings, The timer shall contain one instantaneous contact and one delayed contact. Time shall be adjustable from .05 seconds to 30 days. Timer is energized with the 100% Airflow Override button. When button is depressed, time starts and fans go to high speed. Upon timeout, fans return to low speed or speed dictated by temperature switch, The panels include color coded wiring with as -built wiring diagrams, and spare terminals controlled by the fire system micro switch, The panel is factory pre -wired to shut down supply fans in a fire condition, There is also a factory pre -wire option to turn on the exhaust fans in o. fire condition Cif required). %ENERGY MANAGEMENT SYSTEM JOB NAME Bayou Grill — Southcenter DATE 9/1/2010 DRAWING NUMBER EMS21183- 1209916 — #1 -3 1 JOB NUMBER 1209916 MODEL EMS21183 26 27 I}0- 10VDC 5K;NAL OUT F REQUIRED 1 28 RE-09 -2 en-gi two® 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 RE -01 -2 Cyl t4CGY 1 R181 9;28 Y 1 1I -01 INSTANT SM-01 (SUP -: 11 7 I 13B 1 3Y 2 4 25 13A as-® oster4en RQJ� 51.4 -02 (001-1) 11 H00011. TEMP HIGH RD 2 4 25 13A 138 13C 30 5 � CY SM -03 (EXH -2) 11 1 RI) 4 25 13A 138 13C 30 5 HOOlitf81.1P HIGH RR 1tY TO 3 INPUT 3 INPUT PHASE POWER" PHASE POYi " MOTOR(S) INVERTER DUTY MOTOR(S) 3 INPUT PHASE POWER" INVERTER DUTY MOTOR(S) All external control wires to motor speed control should be 16 -20 AWG shielded multiconductor cables and must not be run in the same conduit or raceway with any high power wiring. Ground Shielded Cable at the drive chasis ONLY. PG. 14 of the AC TECH SMV drive manual describes the electrical installation. ` gp PG. 23 of the AC TECH SMV drive manual describes the parameter \` sepUpgp of the drive. Hood Light SwItelliox 10000ds Exhaust On In Fire Lights Out in Firs Opera 1 PONENT IDENTIFICATION IRE-Ot DPDT Rday- 34.110.014&0 IRE -O9Fm ON Rday- 31.110.01411.0 r1-01 Sup Speed Contra s(-V SERIES M- 02Ex(i Speed Control-WV SERIES 1-035th Speed Control -WV SERIES Los tI9a (23129] [5128] E� 2 3- 36 -38 ITC- XXTenparature Controller-PXR3 r4ON Rai Haunt TC PARAMATERS (400 -450' Hoods) Sv - 85 LEVEL 1: A1-H - 85 AL2 - 90 LEVEL 2 P 2.5 [P= (SV- H )-(61.- L)) /2] LEVEL 3: SV -L - 85 SV -H = 90 TC PARAMATERS (600 -700' Hoods) Sv - 85 LEVEL 1: A1-H = 85 AL2 = 130 LEVEL • 22.5 2 [P =(SV-H)- (SV- L)) /2] LEVEL 3: 85 SV-H - 130 "3 PHASE INPUT, USE L1, L2,1.3. 1 Phase 240 VAC INPUT, USE LI b L2 On1y- 1 Phase 120 VAC INPUT, USE LI 3 N Only. GENERAL DRIVE PARAMETER SETTINGS (PW .225) SUPPLY FAN DRIVE EPM PROGRAM 01 P100 -01 (Tenn Soft) P101 -03 (Preset 01) P102 -0 Hz (MH Freq) P103 -60 Hz (Max Frey P104 -30 SEC. (Accel Time) P105 -30 SEC. (Decal Tine) P110 -03 (Auto Restart) P121 -01 (0 -10 VDC) P122 -03 (Preset Speed 02) P123 -03 (Preset Speed 03) P132 -0 Kt (Wash Cycle Freq) P133 -60 Hz (Must Match P103) P138 -60 He (Must Match P103) P140 -01 Om) P144 -00 (No Inverse P140) P145 -50% (Adjust (0 Startup) P146 -5 SEC (Loss load Delay) P150 - 01(0 -10 VDC Output) P151 -00 (No OutputAAdRion) P152-GO Hz (Freq Scadg) P160 -0 Hz (Mir Signal Speed) P101 -80 Hz (Max Signal Speed) (Must Match P103) EXHAUST FAN DRNE(S) EPM PROGRAM 013 P100 -01 (Term Sett) P101 -03 (Preset i1) P102 -0Ite (Min Freq) P103 -60 Hz (Max Freq) P104 -30 SEC.(Accel Terse) P105 -30 SEC. (Decal Tone) P110 -03 (Auto Restart) P121- 02(420 MA) P122 -03 (Preset Speed 02) P123 -03 (Preset Speed 03) P132 -15 Hz (Wash Cycle Freq) P133 -60 Hz (Must Match P103) P138 -60 Hz (Must Match P103) P140 -10 (Loss Of Load) P144 -01 (Inverse P140) P145- 50%(Adust etNhq) P151 -01 TIi9W40 4 P151 -01 (ADD TB&to Te30) P102 ee R20,61a 1e P161 -60 Hz (Max Signal Speed) (Must Match P103) Ad et mmud a1 dl amuse PI - 00 Of ly 120 arc" 208 VAC) m 01 Of 230, 480 or 57. VAC) - Pt MOWN TYPE x pu. 2 (PI OPEN CLCSm OPEN 3 (PI OPEN OPEN CLOSED e (P136 OPEN CLOSED MOM) MOWN TYPE PH VOLT IP FLA =:• ..,r: T' =I =I 13111=1131EE111= =I 77"171 EllEMIEE111= NOTES - - -- FELD WIRING INTERNAL WRING ® TERMINAL IN PANEL tap TERMINAL IN PANEL AND REMOTE Drawing shown De- energized. ARUM= BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY OR - ORANGE OR/BL - ORANGE/BLUE RD _ Ron ((`TRIPE) Wrl PR - PURPLE (STRIPE) BLUE/RED PK - PINK RD /GN - RED /GREEN J (CTRIPFI Fan) Iii :bltvvi=U FOR ,ODE COMPLIANCE ; ro i i_ [3;i 07 2U10 City of Tukwila 3UILfING DIVISION M CITY OF TUKKWILA SEP 2 8 2010 PERMIT CENTER REVISIONS DESCRIP'iION DATE SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com Grill -Sou -thcen±er J 0 d Pq CD 1 DATE: 9/1/2010 DWG. #: 1209916 DRAWN Y: SCALE: 1/16 MASTER DRAWING '. EET NO. 3 GENERAL NOTES 1) COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE MOST CURRENT BUILDING, MECHANICAL, ENERGY, PLUMBING, FIRE AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2) ALL AIR - CONDITIONING UNITS WITHOUT INTERNAL TRAP SHALL HAVE A P -TRAP FOR THE CONDENSATE PAN WITH PLUG TEES FOR CLEANING AND CONDENSATE PIPES SHALL BE DISCHARGED TO EXISTING CONDENSATE WASTE PIPING. VERIFY SIZE AND LOCATION AT SITE. 3) MECHANICAL CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. 4) ALL FIRE RATED STRUCTURE SHALL BE FIRE DAMPERED. VERIFY WITH THE ARCHITECTURAL AND INSTALL PER THE LOCAL JURISDICTIONS. 5) ALL AIR DISTRIBUTION OUTLETS SHALL HAVE VOLUME CONTROL DEVICES. 6) ALL VOLUME DAMPERS IN NON- ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION ( "YOUNG" REGULATIONS OR EQUAL). EXACT LOCATION OF CONTROL DEVICES VISIBLE IN FINISHED SPACES SHALL BE COORDINATED WITH THE ARCHITECT. 7) ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 8) MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF PIPING AND DUCTWORK AND PENETRATIONS WITH THE STRUCTURE. 9) MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 6' OR AS SHOWN ON DRAWINGS. 10) ALL DUCTWORK, EQUIPMENT AND PIPING SHALL BE SEISMICALLY SUPPORTED PER SMACNA AND LOCAL REGULATIONS. 1 1) ALL AIR FILTERS SHALL HAVE EFFICIENCY BASED ON THE ASHRAE STANDARD 52 -76 (ATMOSPHERIC DUST SPOT). 12) ALL MECHANICAL EQUIPMENT SHALL CONFORM TO SMACNA AND LOCAL REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). 13) ALL EQUIPMENT AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. 14) TOTAL SYSTEM SHALL BE WARRANTED FOR ONE YEAR; STARTING FROM THE TIME OF OWNER /ENGINEER'S FINAL ACCEPTANCE. 15) HVAC NOTES: A) PROVIDE FLEXIBLE CONNECTION IN ALL DUCTS CONNECTING TO AIR MOVING EQUIPMENT AS CLOSE TO FAN AS POSSIBLE. FLEXIBLE CONNECTION SHALL CONSIST OF 6" OR MORE OF AIR TIGHT, FIREPROOF FLEXIBLE NEOPRENE COATED WOVEN FIBROUS GLASS MATERIAL. VENT FABRICS, INC. OR APPROVED EQUAL. B) ALL DUCTWORK SHALL BE SHEET METAL. SOUND LINE RECTANGULAR SUPPLY AND RETURN DUCTS WITHIN 10 FEET FROM THE UNIT OPENINGS. C) . ALL SUPPLY AND RETURN FLEXIBLE DUCTS SHALL BE CONSTRUCTED OF DOUBLE LAMINATION OF POLYESTER ENCAPSULATED STEEL WIRE HELIX FOR INNER CORE HIGH DENSITY FIBERGLASS INSULATION AND GRAY POLYESTER FILM WITH SPIRAL REINFORCEMENTS EQUAL TO "ATCO -70 SERIES" (MIN. POS. PRESS. = 6" W.G., NEG. PRESS = 0.75" W.C.). D) PROVIDE LOCKABLE VOLUME DAMPERS IN ALL AIR DISTRIBUTION OUTLETS. E) DUCT HANGERS, SUPPORTS AND METHODS OF INSTALLATION SHALL CONFORM TO ASHRAE AND SMACNA RECOMMENDATIONS. F) DUCT SIZES SHOWN ON PLANS INDICATE INSIDE FREE AREA. G) ALL DUCTWORK SHALL BE CLASS 1 AIR DUCT AS APPROVED BY U.L. -181. H) DUCTS - SHEET METAL DUCTS SHALL BE INSULATED WITH THE INSULATION AND THICKNESSES AS SHOWN HEREIN (REDUCE THE INSULATION THICKNESS BY THERMAL VALUE OF SOUND LINING). 1. SUPPLY AIR DUCTS IN HEATED SPACE; NO INSULATION REQUIRED IF SOUNDLINED, OTHERWISE 1" THICK K = 0.23 © 75 DEGREES F. 2. SUPPLY AIR DUCTS IN NON- HEATED SPACE; APPROXIMATELY 3" THICK K =0.23 © 75 DEGREES F., TO PROVIDE A MINIMUM THERMAL RESISTANCE VALUE OF MINIMUM R -11. 3. SUPPLY AIR DUCTS OUTSIDE OF BUILDING SAME AS CONDITIONED SPACE EXCEPT WITH WEATHERPROOF BARRIER. 4. RETURN AIR DUCTS; SHALL HAVE SAME INSULATION AS THE SUPPLY AIR DUCTS. 5. EXHAUST AIR DUCTS; NO INSULATION REQUIRED. 6. INDOOR DUCTS HANDLING OUTSIDE AIR SHALL HAVE FIBERGLASS BLANKET WITH VAPOR BARRIER JACKET ASJ, 1" THICK, K = 0.23 © 75 DEGREES F. (ALL DUCTWORK FOR THE BUILDING SUPPLY FAN AND OUTSIDE AIR INTAKES TO INDIVIDUAL HEAT PUMPS). REFRIGERANT PIPING: SUCTION LINES SHALL HAVE 1" MINIMUM INSULATION. I) 16) THE CONTRACTOR SHALL NOT OPERATE THE EQUIPMENT FOR TEMPORARY HEATING OR VENTILATION DURING THE CONSTRUCTION. (ALL EQUIPMENT SHALL RUN FOR TESTING AND BALANCING PURPOSES ONLY). NOTIFY THE ENGINEER 48 HOURS (MINIMUM) IN ADVANCE TO ARRANGE A FINAL FIELD INSPECTION PRIOR TO COVERING UP THE CEILING. 17) EACH FAN UNIT OVER 2000 CFM SHALL HAVE A DUCT /SMOKE DETECTOR PER 2006 IMC 606 IN RETURN DUCTS AS REQUIRED BY THE JURISDICTIONS. UNIT SHALL SHUT DOWN UPON SMOKE DETECTION (COORDINATE WITH FIRE ALARM CONSULTANT /CONTRACTOR PRIOR TO BIDDING /CONSTRUCTION). 18) CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING THE CONTRACT ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE. SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND PER LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE STANDARDS WITH THE ARCHITECT /ENGINEER'S APPROVAL. 19) ALL EQUIPMENT SUPPLIED FOR THESE SPECIFICATIONS SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF IT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT DOES NOT MEET THE WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY. NO WARRANTY OF MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. (THE WARRANTY SHALL START FROM THE TIME OF ARCHITECT /ENGINEER'S FINAL ACCEPTANCE.) 20) ENTIRE INSTALLATION OF ALL EQUIPMENT, CONTROL, PIPING, DUCTWORK AND RELATED ACCESSORIES SHALL BE PER BASIC OWNERS' STANDARDS. MECHANICAL CONTRACTOR IS TO FAMILIARIZE HIMSELF WITH THESE STANDARDS. 21) MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY THE ROUTING AND INSTALLATION FEASIBILITY OF ALL EQUIPMENT, PIPING AND DUCTWORK PRIOR TO SUBMITTING HIS BID AND INCLUDE IN HIS BID ADDITIONAL PIPING, DUCTWORK, FITTINGS, OFFSETS, ETC. WHICH MIGHT BE REQUIRED FOR A COMPLETE SYSTEM READY FOR OWNER'S BENEFICIAL USE. 22) COORDINATE THE CONSTRUCTION SCHEDULE WITH THE ARCHITECT AND PERFORM ALL REQUIRED WORK IN STRICT ACCORDANCE WITH THE OWNER'S SCHEDULE. 23) MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND CERTIFICATES REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. 24) ADJUST ALL EQUIPMENT AND PERFORM A COMPLETE AIR - BALANCING AND PUT ALL MECHANICAL SYSTEMS IN OPERATION AND SUBMIT MINIMUM 4 COPIES OF BALANCING REPORTS TO THE OWNER /ARCHITECT. INSTRUCTION TO BIDDERS 1. VERIFY WITH LANDLORD AND GENERAL CONTRACTOR FOR LANDLORD FURNISHED ITEMS PRIOR TO BIDDING /CONSTRUCTION. 2. DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACTOR SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. 3. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTOR'S COST. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. GENERAL SPECIFICATIONS A. IT IS THE INTENT OF THESE SPECIFICATIONS TO PROVIDE A MECHANICAL SYSTEM COMPLETE, FULLY ADJUSTED, AND READY TO USE. B. INSPECTION: PRIOR TO ALL WORK OF THIS DOCUMENT, CAREFULLY INSPECT THE INSTALLED WORK OF ALL OTHER TRADES AND VERIFY THAT ALL SUCH WORK IS COMPLETE TO THE POINT WHERE THIS INSTALLATION MAY PROPERLY COMMENCE. VERIFY THAT THE WORK MAY BE COMPLETED IN STRICT ACCORDANCE WITH ALL PERTINENT CODES AND REGULATIONS, THE APPROVED SHOP DRAWINGS, AND THE MANUFACTURERS' RECOMMENDATIONS. C. DISCREPANCIES: IN THE EVENT OF DISCREPANCY, IMMEDIATELY NOTIFY THE ARCHITECT /ENGINEER. DO NOT PROCEED IN AREAS OF DISCREPANCY UNTIL ALL SUCH DISCREPANCIES HAVE BEEN FULLY RESOLVED. D. INSPECTION: CHECK EACH PIECE OF EQUIPMENT IN THE SYSTEM FOR DEFECTS, VERIFYING THAT ALL PARTS ARE PROPERLY FURNISHED AND INSTALLED, THAT ALL ITEMS FUNCTION PROPERLY, AND THAT ALL ADJUSTMENTS HAVE BEEN MADE. E. GENERAL: DO NOT ALLOW OR CAUSE ANY OF THE WORK OF THIS SECTION TO BE COVERED UP OR ENCLOSED UNTIL IT HAS BEEN INSPECTED, VIEWED AND ACCEPTED BY THE LANDLORD /ARCHITECT/ ENGINEER AND BY ALL OTHER AUTHORITIES HAVING JURISDICTIONS. F. DO ALL THINGS NECESSARY TO COOPERATE WITH OTHER TRADES IN ORDER THAT ALL SYSTEMS IN THE WORK MAY BE INSTALLED IN THE BEST ARRANGEMENTS. COORDINATE AS REQUIRED WITH ALL OTHER TRADES TO SHARE SPACE IN COMMON AREAS AND TO PROVIDE THE MAXIMUM OF ACCESS TO EACH SYSTEM. G. IT IS THE INTENT OF THESE SPECIFICATIONS THAT ALL WORK, INCLUDING THE INSIDE OF EQUIPMENT, FIXTURES, PIPING, DUCTWORK, ETC. BE LEFT IN A CLEAN CONDITION. ALL CONSTRUCTION DIRT SHALL BE REMOVED FROM MATERIAL SITE AND EQUIPMENT. H. IT IS THE INTENTION OF THESE SPECIFICATIONS AND DRAWINGS TO CALL FOR FINISHED WORK, TESTED, AND READY FOR OPERATION. WHEREVER THE WORK "PROVIDE" IS USED, IT SHALL MEAN "FURNISH AND INSTALL COMPLETE AND READY TO USE." MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR THE PROPER INSTALLATION AND OPERATION, SHALL BE INCLUDED IN THE WORK, THE SAME AS IF HEREIN SPECIFIED OR SHOWN. I. THE CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS AND PAY ALL GOVERNMENT SALES TAXES, FEES AND OTHER COSTS, INCLUDING UTILITY CONNECTIONS OR EXTENSIONS, IN CONNECTION WITH HIS WORK; FILE ALL NECESSARY PLANS, PREPARE ALL DOCUMENTS AND OBTAIN ALL NECESSARY APPROVALS OF ALL GOVERNMENTAL DEPARTMENTS HAVING JURISDICTION; OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION OF HIS WORK AND DELIVER SAME TO THE ARCHITECT BEFORE REQUEST FOR ACCEPTANCE AND FINAL PAYMENT FOR WORK. J. THE CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA COST TO THE OWNER, ANY LABOR, MATERIALS, SERVICES, APPARATUS, DRAWINGS, IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES AND REGULATIONS, WHETHER OR NOT SHOWN ON DRAWINGS AND /OR SPECIFIED. K. SURVEYS AND MEASUREMENTS: THE CONTRACTOR SHALL BASE ALL MEASUREMENTS, BOTH HORIZONTAL AND VERTICAL, FROM ESTABUSHED BENCH MARKS. ALL WORK SHALL AGREE WITH THESE ESTABLISHED LINES AND LEVELS. VERIFY ALL MEASUREMENTS AT SITE AND CHECK THE CORRECTNESS OF SAME AS RELATED TO THE WORK. L. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. DRAWINGS ARE NOT TO BE SCALED. THE ARCHITECTURAL DRAWINGS AND DETAILS SHALL BE EXAMINED FOR EXACT LOCATION OF FIXTURES AND EQUIPMENT. WHERE THEY ARE NOT DEFINITELY LOCATED, THIS INFORMATION SHALL BE OBTAINED FROM THE ARCHITECT. M. PROTECTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR WORK AND EQUIPMENT UNTIL FINALLY INSPECTED, TESTED, AND ACCEPTED; HE SHALL PROTECT WORK AGAINST THEFT, INJURY OR DAMAGE; AND SHALL CAREFULLY STORE MATERIAL AND EQUIPMENT RECEIVED ON SITE WHICH ARE NOT IMMEDIATELY INSTALLED. HE SHALL CLOSE OPEN ENDS OF WORK WITH TEMPORARY COVERS OF PLUGS DURING STORAGE AND CONSTRUCTION TO PREVENT ENTRY OF OBSTRUCTING MATERIAL. N. THE CONTRACTOR SHALL FURNISH ALL SCAFFOLDING, RIGGING, HOISTING, AND SERVICES NECESSARY FOR ERECTION AND INSTALLATION OF THE MECHANICAL SYSTEM. 0. CONTRACTOR SHALL LOCATE ALL EQUIPMENT WHICH MUST BE SERVICED, OPERATED, OR MAINTAINED IN FULLY ACCESSIBLE POSITIONS. P. THIS CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING NECESSARY TO INSTALL THE WORK SPECIFIED IN THIS SECTION. PATCHING SHALL MATCH ADJACENT SURFACES. Q. NO STRUCTURAL MEMBERS SHALL BE CUT WITHOUT THE APPROVAL OF THE ARCHITECT, AND ALL SUCH CUTTING SHALL BE DONE IN A MANNER DIRECTED BY HIM. R. THIS CONTRACTOR SHALL PROVIDE AND LOCATE ALL SLEEVES AND INSERTS REQUIRED BEFORE THE FLOORS AND WALLS ARE BUILT, OR SHALL BE RESPONSIBLE FOR THE COST OF CUTTING AND PATCHING REQUIRED FOR PIPES WHERE SLEEVES AND INSERTS WERE NOT INSTALLED, OR WHERE INCORRECTLY LOCATED. THE CONTRACTOR SHALL DO ALL DRILLING REQUIRED FOR THE INSTALLATION OF HIS HANGERS. S. SLEEVES SHALL BE PROVIDED FOR ALL MECHANICAL PIPING PASSING THROUGH CONCRETE FLOOR SLABS AND CONCRETE, MASONRY, TILE AND GYPSUM WALL CONSTRUCTION. ALL INSULATION SHALL HAVE A COMPOSITE (INSULATION, JACKET OR FACING, AND ADHESIVE) FIRE HAZARD RATING AS TESTED BY ASTM E -84, NFPA 255, OR UL 723, NOT TO EXCEED 25 FLAME SPREAD AND 50 SMOKE DEVELOPED. ACCESSORIES SUCH AS COATINGS, TAPES, AND ADHESIVES SHALL HAVE THE SAME COMPONENT RATINGS. ALL INSULATING MATERIALS OR THEIR CONTAINERS SHALL HAVE A LABEL INDICATING COMPLIANCE WITH THE ABOVE RATING. REFERENCE STANDARDS: NFPA D -255, A.S.T.M. E -84, UL -723, ASHRAE 90 -75 AND THE STATE ENERGY CODE. ACCEPTABLE MANUFACTURERS: CERTAINTEED, OWENS- CORNING, KNAUF AND MANVILLE. U. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A COMPLETE OPERATING AND MAINTENANCE MANUAL AND ONE SET OF MYLAR REPRODUCIBLES SHOWING ALL AS -BUILT CONDITIONS. THE MANUALS SHALL INCLUDE ALL MANUFACTURER'S SPECIFICATIONS, OPERATION, MAINTENANCE, INSTRUCTIONS, WARRANTY, LOCAL SOURCE OF SUPPLY FOR SPARE PARTS AND SERVICES, ETC.. T. V. PROVIDE WEATHERPROOF FLASHING AT ALL DUCT, PIPE, ETC., MECHANICAL PENETRATIONS THROUGH THE BUILDING WALLS AND ROOF. FLASHING SHALL BE DESIGNED AND INSTALLED PER SMACNA AND SHALL BE GUARANTEED WEATHER PROOF FOR THE DURATION OF THE GUARANTEE. W. PIPE MATERIAL: COLD WATER AND HOT WATER COPPER "L" (LEAD FREE) WASTE AND VENT CAST IRON, DWV COPPER NOTE: JOINTS AND METHOD OF CONNECTIONS SHALL BE PER THE UPC - CHAPTER #8, ASTM STANDARDS AND MANUFACTURERS RECOMMENDATIONS FOR EACH PIPE TYPE AND APPLICATIONS. X. PIPE INSULATION: COLD WATER - 1/2" INSULATION WITH VAPOR BARRIER JACKETS. HOT WATER - 1/2" INSULATION WITH VAPOR BARRIER JACKETS. FOR RUNOUTS UP TO 12 FEET, AND 1" INSULATION FOR ALL PIPING UP TO 2" DIAMETER. UNDERGROUND PIPING WITH 1" CLOSED CELL FOAM INSULATION. ENERGY CODE NOTES: 1) THERMOSTATS SHALL BE A 7 DAY PROGRAMMABLE TYPE WITH A 5 DEGREE DEADBAND AND AUTOMATIC SETBACK CONTROL PER 1412.2 WASHINGTON STATE ENERGY CODE. 2) HVAC EQUIPMENT SHALL MEET THE MINIMUM ENERGY EFFICIENCY RATINGS PER TABLE 14 -1, 14 -2 AND 14 -3 OF THE WASHINGTON STATE ENERGY CODE. 3) DUCT INSULATION AND SEALING SHALL MEET CHAPTER 14 SECTION 1414 REQUIREMENTS. 4) SUPPLY AND RETURN DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO MIN. R -8. ROOFTOP HVAC DUCTWORK SHALL HAVE A WEATHER BARRIER. 5) SUPPLY AND RETURN DUCTS IN CONDITIONED SPACES SHALL BE INSULATED TO MIN. R -4. UNCONDITONED SPACES SHALL BE R -7. 6) PIPING INSULATION SHALL MEET THE REQUIREMENTS OF WASHINGTON STATE ENERGY CODE TABLE 14 -6. 7) CONTRACTOR SHALL SUBMIT RECORD DRAWINGS AND OPERATING AND MAINTENANCE MANUALS PER 1416 WSEC. 8) CONTRACTOR SHALL PERFORM AND SUBMIT AN AIR BALANCE REPORT PER 1416.3.1 PER WSEC. 9) CONTRACTOR SHALL SUBMIT A COMMISSIONING REPORT AND DOCUMENTATION PER 1416.4 PER WSEC. ROOFTOP PACKAGE HEAT PUMP SCHEDULE DESIGNATION: HP-1 ZONE: RESTAURANT MANUFACTURER: CARRIER MODEL: 50EZ -042 DISCHARGE: DOWN NOMINAL TONS 3.5 COOLING • ARI (MBH): 40.5 HEATING CAPACITY - LOW TEMP (MBH): 21.8 E.E.R.: 11.2 S.E.E.R: - - AUX. HEAT KW 7.5 FAN MOTOR, HP: 3/4 HP CFM: 1400 E.S.P. (IN -H20): 0.50" INDOOR /OUTDOOR FAN(FLA): 3.0/0.6 COMPRESSOR RLA /LRA: 6.3/44.0 MCA /MOCP (AMP): 26.5/30 VOLTAGE /PHASE 460V/30 WEIGHT (LBS): 650 REMARKS: (1) 880H TOP WALL GRILLE (1) WITH 100% MODULATING ECONOMIZER, CRANKCASE HEATER /COMPRESSOR SHORT CYCLE PROTECTION/ HI PRESSURE SWITCH, LO PRESSURE SWITCH /TIME GUARD CIRCUIT /DEFROST CONTROL /BAROMETRIC RELIEF/ ROOF CURB AND 2" THROW AWAY FILTER AND VIBRATION ISOLATORS. KITCHEN HOOD /MAKE -UP AIR SCHEDULE DESIGNATION: KEF -1 KEF -2 MAU -1 ZONE: HOOD 1 HOOD 2 HOODS 1 & 2 MANUFACTURER: CAPTIVE AIRE CAPTIVE AIRE CAPTIVE AIRE REMARKS: (1) (2) (3) (1) REFER TO HOOD DRAWINGS FOR FULL SPECIFICATION, NOTED AS FAN #1 ON HOOD PLANS (2) REFER TO HOOD DRAWINGS "H -2, 3 & 4" FOR FULL SPECIFICATION, NOTED AS FAN #3 ON HOOD PLANS. (3) REFER TO HOOD DRAWING "H -1, 3 & 4" FOR FULL SPECIFICATION, NOTED AS FAN #2 ON HOOD PLANS AIR DISTRIBUTION SCHEDULE TYPE DESCRIPTION CFM NECK SIZE MODEL REMARKS A ROUND SUPPLY DIFFUSER PER PLAN PER BELOW RM1 AIR DIST. 4 -WAY UNLESS NOTED OTHERWISE B T -BAR SUPPLY DIFFUSER PER PLAN PER BELOW SH AIR DIST. 4 -WAY UNLESS NOTED OTHERWISE C SOLID CLG. SUPPLY DIFFUSER PER PLAN PER BELOW SH AIR DIST. 4 -WAY UNLESS NOTED OTHERWISE D SOLID CLG. RETURN /EXH. GRILLES PER PLAN PER BELOW S8OH BOTTOM /TOP WALL GRILLE E T -BAR RETURN /EXH. GRILLES PER PLAN PER BELOW EGC5 AIR DISTRIBUTION VERTICAL /HORIZ. KRUEGER F TOP WALL GRILLE PER PLAN PER BELOW 880H TOP WALL GRILLE G THERMAFUSER PER PLAN PER BELOW TF -HC THERMAFUSER OR EQUAL H MAKE -UP AIR DIFFUSER PER PLAN 14X14 6200 WITH PERFORATED GRILLE DISTRIBUTION PER PLANS DUCT SIZE FEEDING THE AIR DISTRIBUTION - (1) NO UNDERGROUND WASTE PIPING LESS THAN 2 ". (2) SEE ARCH. AND KITCHEN DESIGN FOR FIXTURE SPECIFICATIONS NECK NECK NECK NECK SIZE CFM (MIN.) CFM (MAX) TYPE A (RM1) TYPE B (RM1) TYPE- C (SH) TYPE- D (S8OH) MAX. NC = 35 4 "0 0 35 6 X 6 6 X 6 5"0 36 60 6 X 6 6 X 6 6 "0 61 95 6 X 6 6 X 6 no 9 6 145 6 X 6 8 X 6 8 "g) 146 200 6 X 6 10 X 6 9 "0 201 280 9 X 9 10 X 6 10"0 281 380 9 X 9 12 X 10 12 "0 381 600 12 X 12 18 X 10 14 "0 601 900 15 X 15 24 X 12 1 16 "0 901 1300 24 X 18 18 "0 1301 1750 24 X 24 20x20 2610 3265 20 x 20 MAX. NC = 35 NOTES: 1) CEILING DIFFUSERS, REGISTERS AND GRILLES SHALL BE KRUEGER OR EQUAL. 2) CD= CEILING DIFFUSER, RG= RETURN GRILLE, TG= TRANSFER GRILLE, LVR= LOUVER, TWG =TOP WALL GRILLE, BWG= BOTTOM WALL GRILLE. 3) ALL SUPPLY AIR DISTRIBUTION OUTLETS WITHOUT VOLUME DAMPERS SHALL HAVE OPPOSED BLADE VOLUME CONTROL DAMPERS. 4) FASTENING METHOD SHALL BE AS SELECTED BY ARCHITECT AND SHALL BE COMPATIBLE WITH THE WALL OR CEILING STRUCTURE THAT IS BEING INSTALLED. 5) OTHER APPROVED MANUFACTURERS ARE: TITUS, E.H. PRICE, METALAIRE AND J & J. ALTERNATE MANUFACTURERS MUST MATCH MATERIALS, TYPE, AND PERFORMANCE OF LISTED DEVICE. BACKFLOW PREVENTER NOTES 1. AS MANUFACTURED BY "WATTS" OR EQUAL: RPBA = REDUCED PRESSURE #009QT DCVA = DOUBLE CHECK #007QT AVB = VACUUM BREAKER 2. VALVES TO BE UNE SIZE. 3. INSTALL AT THE FOLLOWING LOCATIONS (MINIMUM): A. ONE 1/2" RPBA AT ICE MAKER B. ONE 1/2" RPBA AT COFFEE BREWER /ESPRESSO MACHINE (IF INSTALLED) ONE MOP SINK WITH INTEGRAL VACUUM BREAKER FAUCET ONE 1/2" (OR LINE SIZE, VERIFY WITH BEVERAGE PROVIDER) RPBA AT BEVERAGE BAR /CARBONATOR, MUST BE APPROVED BY WASHINGTON STATE FOR USE AT CARBONATED BEVERAGE EQUIPMENT (POP MACHINE PIPING DOWNSTREAM OF CARBONATOR SHALL BE PLASTIC IN ORDER TO AVOID CARBONIC POISONING. BACKFLOW PREVENTERS SHALL BE MOUNTED 5 FELT MAXIMUM ABOVE FLOOR PER UPC 2006, SEC. 603.3.4. RUN AIR GAP WASTES FROM RP DEVICES TO FLOOR SINKS. ONE 3/4" RPBA AT DISHWASHER. ONE 1/2" RPBA AT MAKE -UP AIR WATER CONNECTION. C. D. E. F. G. ELECTRIC WATER HEATER SCHEDULE DESIGNATION: WH -1 ZONE: RESTAURANT MANUFACTURER: A.O. SMITH (OR EQUAL) MODEL: DVE -120 TYPE: TANK KW: 24 NO. OF ELEMENTS: 6 0 4000 EA. (SIMUL.) TEMP. RISE (F): 100 GALLONS: 80 VOLTAGE: 480 PHASE: 3 FLA: 28.9 SHIPPING WEIGHT (LBS): 280 REMARKS: (1)(2)(3) (1) VERIFY AND COORD. WITH ELECTRICAL FOR POWER TO WATER HEATER. (2) INSTALL AND DRAIN P/T VALVE TO AN APPROVED LOCATION PER LOCAL JURISDICTION. (3) WITH EXPANSION TANK, AMTROL #ST -5 'THERM- X- TROL ", DIAPHRAGM TYPE, PRE - PRESSURIZED TANK. M(OI3Z PLUMBING FIXTURE CONNECTION SCHEDULE DESIG ITEM: TRAP: WASTE: VENT: CW: HW: P1 PREP SINK 2" 2" - Y2" 312" P2 3 -COMP. SINK 2" 2" - Y2" Y2" P3 WALL HAND SINK 1Y" 1Y2" 1Y" Y2" Y2" P4 MOP SINK 3" 3" 1Y" 34" 34" P5 COUNTER HAND SINK 1Y" 1Y" 1Y" Yi' Y2" D1 FLOOR DRAIN 2" 2" 1Y" - - D2 FLOOR SINK 2" 2" 1Y2" - - (1) NO UNDERGROUND WASTE PIPING LESS THAN 2 ". (2) SEE ARCH. AND KITCHEN DESIGN FOR FIXTURE SPECIFICATIONS MINIMUM OUTSIDE AIR SCHEDULE PER WA. STATE VENT CODE (ASHRAE 62 -1999) EQUIP DESIG. ZONE AREA SQ FT NO. OF PEOPLE MIN. O.S.A CFM / PER. MIN. O.S.A. CFM REQ'D DESIGNED HP -1 KITCHEN 668 13 15 CFM /PERSON 195 350 TOTAL 195 I=IivIlIi ItL) FOR CODE COMPLIANCE w aRmwo 01 2010 City of Tukwila BUILDING OIVI 1O CITY OF TUI WILA SEP 2 8 2010 PERMIT CENTER PLAN INDEX M1 GENERAL NOTES, SPEC., SCHEDULE AND LEGEND M2 PLUMBING - WASTE & VENT M3 PLUMBING - WATER & GAS M4 HVAC M5 MALL - ROOF PLAN M6 DETAILS H1 TYPE 1 HOOD PLAN (INCLUDED FOR REFERENCE ONLY) H2 TYPE 2 HOOD PLAN (INCLUDED FOR REFERENCE ONLY H3 TYPE 3 HOOD PLAN (INCLUDED FOR REFERENCE ONLY PROJECT NAME BAYOU GRILL 2600 Southcenter Mall Space FC-5 '1 ukwila, WA 98188 PERMIT SET NOT FOR BID OR CONSTRUCTION DRAWING TITLE GENERAL NOTES, SCHEDULES AND INDEX JOB NUMBER 210010 DRAWN BY SH CHECKED BY AVA 9/15/10 PERMIT SET ISSUED DATE DESCRIPTION MO1 (OF 6) Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: 425) 462 -9441 FAX: 425) 462 -9451 E- Mail: cseroice @abossein.com www.abossein.com PROJECT NAME BAYOU GRILL 2600 Southcenter Mall Space FC-5 '1 ukwila, WA 98188 PERMIT SET NOT FOR BID OR CONSTRUCTION DRAWING TITLE GENERAL NOTES, SCHEDULES AND INDEX JOB NUMBER 210010 DRAWN BY SH CHECKED BY AVA 9/15/10 PERMIT SET ISSUED DATE DESCRIPTION MO1 (OF 6) LOCKING PROGRAMMABLE T'STAT 14 "0 EACH, TYP. 990CFM -H TYP. FOR EA. MAKE -UP AIR OUTLET, DIRECT AIRFLOW AWAY FROM HOOD, TYP. PROVIDE GREASE DUCT CLEAN -OUT AT CHANGE IN DIRECTION, TYP. LEGEND sYlu®ot_ ABBREVIATION DEMON QT /Qs T'STAT /SENSOR THERMOSTAT /SENSOR rrr __ DUCTWORK W/ TURNING VANE AND FLEX CONN. -J VD VOLUME DAMPER -- RIGID DUCT -- FLEXIBLE DUCT W -- ROUND SPIN -IN WITH V.D. FD FIRE DAMPER -4 SFD SMOKE FIRE DAMPER -4 • CFD CEILING RADIATION FIRE DAMPER 8 CD ROUND CEILING DIFFUSER CG ROUND CEILING GRILLE g CD SQUARE CEILING DIFFUSER V CG SQUARE CEILING GRILLE CD CD CONDENSATE DRAIN LINE 4 -- SMOKE DUCT DETECTOR A.F.F. ABOVE FINISHED FLOOR 16 "0 TYPE 1 HOOD EXHAUST, OFFSET AS NEEDED TO ROUTE UP TO KEF -1 & KEF -2 ON ROOF, COORD. AT SITE FOR EXACT LOCATION TRANSITION TO UNIT OPENINGS, TYP. HVAC PLAN SCALE: 1/4" = 1' -0" UP TO MAKE -UP AIR UNIT, TRANSITION TO UNIT OPENING NOTE: SEE KEY PLAN SHEET "M -6" FOR MALL LOCATION WITHIN MALL, TYP. NOTE: TYPE I HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCE, BY MEANS OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS. FOR MECHANICAL MAKE -UP AIR SYSTEMS, THE EXHAUST AND MAKE -UP AIR SYSTEMS SHALL BE ELECTRICALLY INTERLOCKED TO ENSURE THAT MAKE -UP AIR IS PROVIDED WHENEVER THE EXHAUST SYSTEM IS IN OPERATION. MAKE -UP AIR INTAKE OPENING LOCATIONS SHALL COMPLY WITH SECTIONS 401.4 & 401.4.1 (IMC 507.2.1.1 & 508.1) (SEE HOOD DRAWINGS FOR CONTROLS AND INTERLOCK SPECIFICATIONS) M(O� CODE COMPLIANCE OCT 0 7 2010 City of Tulavila • UUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 2 8 2010 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL, - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BEL,LEVUE, WA 98004 PH: 425 462 -9441 FAX: 425 462 -9451 E -Mail: service @abossein,com www.abossein.com PROJECT NAME BAYOU GRILL 2600 Southcenter Mall S� pace FG5 Tukwila, WA 98188 PERMIT SET NOT FOR BID OR CONSTRUCTION DRAWING TITLE FLOOR PLAN - HVAC JOB NUMBER 210010 DRAWN BY 5}{ CHECKED BY AVA 9/15/10 PERMIT SET ISSUED DATE DESCRIPTION M04 (OF 6) - "12_ "O 1Y Ali N . I _D DIN B 0 0 7 M A C --- J --- I---- T- - --t - -T - 1 1 I ` �r i L - -J L - -J 1v1AU -\-1. 1 ROOF PA/RKI \C / JIL4 ] :::�JL \.1l IC_ -�I 0 0 @ 1F --C J1 E- THER 0 o © oc ID NOTE: MALL PLAN ORIENTATION DOES* NOT MATCH ARCH'L. BUILD— i• OUT PLANS, COORD. AT SITE FOR EXACT PLACEMENT, TYP. I 9 �M 7 ; L_ —r _J AC -2I 8 1 0 CONDENSATE TO NDLORD PRO\ DED YS—T €M- — 000RD. -- XACT LOCATION 0' =aa= =m=_asaoczaacaod' s 1' 1 R--c) op (BY U I U RoqID'oP 7\BY FU OTP Ul 011lF S, -05 L 0,,j1pv 0 1"R) ,jR-i R3 TEN AN POCJFTCIP (8 00 l V D AN • \ • L EX< L i MM...s sUi7.44=17s.7snvaam °.Man = =e E LOW- FR NN, F'00 E A I P M E 1\1 T , TYP,._. — AIR INTAKES_ AND B \ SEE KEY PLANI SHE ' M -6" FOR MALL LOCf■TION WITHIN MALL, M AAA _N_ MAC - -8 \\ L— / (0- 132 (-73 i MALL ROOF PLAN SCALE: 1 /8" = 1' —O" 4-: • sAa S Lt..:o h -._$ 0_%.._._3_.• 1 L .3 esi _._.*.W_14.. y C2 '171) M k.11 W F �7.Jr r 1;! o •I. '►./ Z010 icy o Tuljil BUILDING DIVISIiN RECEIV�p KVNL CI7YOFTUA SEP 2 8 2010 PERMIT CENTER Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: 425 462 -9441 FAX: 425 462 -9451 E -Mail: cseroice @abossein,com www.abossein.com PROJECT NAME BAYOU GRILL 2600 Southcenter Mall Space FC-5 Tukwila, WA 98188 PERMIT SET NOT FOR BID OR CONSTRUCTION DRAWING TITLE MALL ROOF PLAN- EQUPMENT LOCATION JOB NUMBER 210010 DRAWN BY 51-1 CHECKED BY AVA 9/15/10 PERMIT SET ISSUED DATE DESCRIPTION M05 (OF 6) 3/4" T &P RELIEF LINE DOWN TO MOP SINK VACUUM BREAKER VALVE. HW I CW T &P VA. G.I. PAN UNDER WATER HEATER W/ DRAIN LINE DOWN TO MOP SINK. DISCHARGE RELIEF LINES FROM WATER HEATER AND PAN SEPARATELY TO MOP SINK EXPANSION TANK WATER HEATER SHALL BE STRAPPED AND BOLTED IN PLACE PER THE MANUFACTURERS RECOMMENDATIONS PER UPC SECTION 508.2 SET ON APPOVED METAL FRAMING SUSPENSION SHELF COORD. AT SITE FOR STRUCTURAL SUPPORT OF WATER HEATER ABOVE MOP SINK, 900LBS EST. WATER HEATER/MOP SINK DE TAIL ( A SCALE: NONE ENSURE REGULATOR IS INSTALLED IN ACCESSIBLE AREA, REGULATORS INSTALLED AT EXTERIOR SHALL BE APPROVED FOR OUTDOOR INSTALLATION ROUTE GAS REGULATOR VENT FULL SIZE TO OUTSIDE, TERMINATE HIGH ON WALL 10' MIN. FROM BLDG. OPENINGS AND OUTSIDE AIR INTAKES INSTALL LISTED SHUT —OFF VALVE IMMEDIATELY AHEAD OF REGULATOR INSTALL PLUGGED TEE FITTING BETWEEN SHUT —OFF AND REGULATOR, INSTALL WITH TEE TURNED DOWN TO ALLOW ACCESS FOR CONNECTION OF PRESSURE MEASURING DEVICE AND TO SERVE AS SEDIMENT TRAP (MIN. 6" DEEP) INSTALL PLUGGED TEE FITTING NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF REGULATOR FOR CONNECTION OF PRESSURE MEASURING DEVICE GAS REGULATOR INSTALLATION DE TAIL SCALE: NONE HINGING KIT FOR FUTURE MAINTENANCE 10' -0 (MIN.) EXHAUST FAN OUTSIDE AIR INTAKES UP —BLAST TYPE DISCHARGE SHALL BE 40' MINIMUM TO FAN DISCHARGE FROM ROOF. PROVIDE CURB HEIGHT ACCORDINGLY. I ✓ —VENTED CIARB EXTENSION (4 SIDES) FOR VENTING OF THE RATED SHAFT. (SEE ARCH'L) _L ROOF MIN. 18' (TYP) FLASH & COUNTER FLASH 16 Ga. WELDED STEEL EXHAUST DUCT. INSIDE 1—HR VENTED SHAFT, SEE ARCH'L. MIN. 6' — 12' MAX. FROM DUCT TO SHAFT. OR PROVIDE LISTED FIRE WRAP, SEE PLANS FOR ADDITIONAL INFORMATION 3' AIR SPAC MIN. �I — MATERIACLEARANCE E . TO COMBUSTIBLE 1 / WELDED GREASE DUCT 1—HR RATED SHAFT OR FIRE WRAP r a GREASE TROUGH WITH GREASE PILLOW OR OTFER APPROVED ABSORBENT MATERIAL COOKING APPLIANCE L ur uJ U.L. CLASSIFIED BAFFLE TYPE GREASE FILTER FLASHING (TYP) FIRE EXTINGUISHING HEAD PER NFPA 96 REQUIREMENTS BY KITCHEN CONTRACTOR. CEILING TYPE -1 EXHAUST HOOD, SEE HOOD DRAWINGS H -1 THROUGH H -4 KITCHEN GREASE HOOD EXHAUST DETAIL NO SCALE TYPE 1 HOOD AND DUCTWORK GENERAL NOTES: A) COMPLETE INSTALLATION OF THE HOOD, FAN AND DUCTWORK SYSTEM SHALL BE PER THE I.M.C. — CHAPTER -5 AND N.F.P.A. #96 AS ADOPTED BY THE LOCAL JURISDICTIONS B) C) D) ALL JOINTS SHALL BE CONTINUOUSLY WELDED GREASE TIGHT. ALL OFFSETS, ELBOWS AND TRANSITIONS SHALL BE SMOOTH — ROUND. HOOD AND DUCTWORK ABOVE CEIUNG (NON— VISIBLE) SHALL BE INSIDE A RATED ENCLOSURE (BY GENERAL CONTRACTOR) WITH AIR SPACE ALL AROUND THE DUCT AND HOOD VENTED TO THE OUTSIDE AT ROOF. CURB HEIGHT SHALL BE MINIMUM 18" ABOVE COMBUSTIBLE ROOF, OR PROVIDE U.L. LISTED FIRE WRAP IN—LIEU OF RATED ENCLOSURE INSTALLED IN STRICT ACCORDANCE WITH IT'S LISTING.. E) CLEANOUTS SHALL BE PROVIDED AT EACH CHANGE OF DIRECTION AND AS REQUIRED BY THE LOCAL JURISDICTIONS WITH ACCESS DOORS AT DUCT AND RATED ENCLOSURES. BOTTOM EDGE OF CLEANOUT SHALL NOT BE LESS THAN 2" ABOVE THE BOTTOM OF DUCT. CLEAN —OUT DOOR AND FRAME SHALL BE FABRICATED OF THE SAME GAUGE METAL AS THE DUCT. PROVIDE 1/8" THICK HIGH TEMPERATURE GASKET, APPROVED FOR USE ON KITCHEN EXHAUST DUCTS BETWEEN FRAME AND DUCT AND BETWEEN DOOR AND FRAME. ALL SEALANT MATERIALS SHALL BE APPROVED FOR HIGH TEMPERATURE INSTALLATION. THE COMPLETE SYSTEM SHALL BE AIR BALANCED AND THE FINAL REPORT SHALL BE SUBMITTED FOR APPROVAL SLOPE DUCTWORK TOWARD HOOD FOR GREASE DRAINAGE PER CODE AND LOCAL JRSD. INSTALL FLASHING FROM THE BACK OF THE HOOD TO THE BACK WALL. INSTALL FLASHING AT CEIUNG FROM HOOD TO 1 HR RATED SHAFT STARTING ABOVE CEILING. FLASHING SHALL BE SAME GAUGE AS HOOD. APPLIANCES UNDER HOOD, HOOD AND GREASE DUCTWORK SHALL HAVE A COMPLETE WET CHEMICAL FIRE SUPPRESSION SYSTEM EQUAL TO ANSUL R -102. COORDINATE WITH KITCHEN CONTRACTOR. COMPLETE INSTALLATION SHALL MEET N.F.P.A.,. U.L AND LOCAL JURISDICTIONS' REQUIREMENTS. HOOD EXHAUST FANS SHALL BE HINGED OPEN FOR CLEANING WITH EXTRA LONG WIRING. ROOFTOP FAN DISCHARGE SHALL BE MINIMUM OF 40 INCHES ABOVE ROOF LEVEL ALL HORIZONTAL GREASE DUCTWORK SHALL HAVE FIRE SUPPRESSION SYSTEM BY BIDDER DESIGN FIRE SPRINKLER CONTRACTOR, (VERIFY WITH G.C.). MIO 132. FL] 11111/11 nuu1niuuuur —14-VIEWED CODE COP/ ADP OCT o'r 2[. City of Tull! BUILDING on CITY OF TUI WILA SEP 2 8 2010 PERMIT CENTER FOR .IA CE Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, !A 98004 PH: 425) 462 -9441 FAX: 425) 462 -9451 E-Mail: cseroice @abossein.com www.abossein.com PROJECT NAME BAYOU GRILL 2600 Southcenter Mall Space FC-5 Tukwila, WA 98188 PERMIT SET NOT FOR BID OR CONSTRUCTION DRAWING TITLE DETAILS JOB NUMBER 210010 DRAWN BY SH CHECKED BY AVA 9/15/10 PERMIT SET nom ISSUED DATE DESCRIPTION M06 (OF 6)