Loading...
HomeMy WebLinkAboutPermit M10-146 - HIGHLINE MEDICAL CENTERHIGHLINE MEDICAL CENTER 12844 MILITARY RD S M10 -146 City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 1623049001 Address: 12844 MILITARY RD S TUKW Project Name: HIGHLINE MEDICAL CENTER Permit Number: M10 -146 Issue Date: 12/13/2010 Permit Expires On: 06/11/2011 Owner: Name: HCH SPECIALTY CENTER Address: ATTN ACCOUNTING DEPT , 12844 MILITARY RD S 98168 Contact Person: Name: RICK ZEHNER Address: 5005 3 AV S , SEATTLE WA 98134 Email: RICKZ @MCKINSTRY.COM Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98134 Contractor License No: MCKINCL942DW Phone: 206 - 832 -8012 Phone: 206 762 -3311 Expiration Date: 03/16/2012 DESCRIPTION OF WORK: NEW ROOFTOP UNIT AND ASSOCIATED DUCTWORK Value of Mechanical: $35,000.00 Fees Collected: $612.31 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2009 Permit Center Authorized Signature: Date: (U I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature � ` r Date: / 2-/3/ Print Name: AA.) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -146 Printed: 12 -13 -2010 • • PERMIT CONDITIONS Permit No. M10-146 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M10-146 Printed: 12 -13 -2010 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us 1 Mechanical Permit No. - to Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION / King Co Assessor's Tax No.: Site Address: /2 "YY /I e/ _Cov>`� Suite Number: Tenant Name: 4'2 lli' -, c.- Gll��.,- ('e,L feil---- New Tenant: Property Owners Name: i' :#Z,. L A,iu/, -4/i/ � Mailing Address: /6' ZS/ Syke- 7e -- goad sevf ((o)-30 '-1 'oo 1 Floor: ❑ Yes a..No City L✓4' State 9g"/6G Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: e-Z1 Ck 5' 3/P ,4 5 Mailing Address: E -Mail Address: gic Day Telephone: City Fax Number: Zee, 98(3y State Zip 0-06 25' z —aoc MECHANICAL CONTRACTORINFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: /f71f 7 7' 3-025 3/a' ,Ave s Contractor Registration Number: /tfe- k //UC` 9 4/Z 1DL.) 9gify City State Zip Day Telephone: ZtXo - 8)3Z - ?O / 2- Fax Number: Z°('- r3Z -3s -7q Expiration Date: 3A/ a ARCHITECT OF RECORD All plans must be stamped by architect of record Company Name: Mt/dpi ,' Mailing Address: Z-2-0 / S' /7;A /fl/eNVe So lte /i(05- 50,A_ Q City Contact Person: 'P ieit C- /■ E -Mail Address: Fax Number: Day Telephone: 9 ,1/Z/ State Zip O — qql - w3JZZ 20(, -fyz. -79/7 ENGINEER OF RECORD - All plans must be stamped by engineer of record Company Name: Lere s -9- 5?( Mailing Address: `Yc9 T,-av✓ /Sf f:3 Contact Person: [c1 -' "/-e.d'l City A.,4 % ROO 7 State Zip Day Telephone: ffZS 31e9- /(O/ E -Mail Address: Fax Number: '7' Zs - Y ` US- 7 H:' pplications\Forms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page I of 2 • • Valuaiir, on of project (contractor's bid price): $ 5;Z _ Scope of work (please provide detailed information): A/e4/ /� vv� Gr G75 Oe�Q.7 J 4 7 e C Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement Fuel Type: Electric Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty -Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3-15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood/gas stove 30-50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic ethe meical equipp menchant air handling unit <10,000 cfm incinerator — comm/ind PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZ AGENT: Signature: Print Name: lsi"-/ . 14/.�.2A- Mailing Address: 5Z7OS — 9I //VC— 5 Day Telephone: City Date: /04'z /o 22x. - 8 rz - 5 `fc w,g 98r3y State Zip Date Application Accepted: I n Date Application Expires: . 11— t Staff Initials: 1 A k H:\Applications\Forns- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1623049001 Address: 12844 MILITARY RD S TUKW Suite No: Applicant: HIGHLINE MEDICAL CENTER RECEIPT Permit Number: M10 -146 Status: APPROVED Applied Date: 10/13/2010 Issue Date: Receipt No.: R10 -02488 Payment Amount: $489.85 Initials: WER Payment Date: 12/13/2010 02:55 PM User ID: 1655 Balance: $0.00 Payee: MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11317 489.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 489.85 Total: $489.85 doc: Receiot -06 Printed: 12 -13 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1623049001 Address: 12844 MILITARY RD S TUKW Suite No: Applicant: HIGHLINE MEDICAL CENTER RECEIPT Permit Number: M10 -146 Status: PENDING Applied Date: 10/13/2010 Issue Date: Receipt No.: R10 -02065 Initials: WER User ED: 1655 Payment Amount: $122.46 Payment Date: 10/13/2010 03:33 PM Balance: $489.85 Payee: MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11132 122.46 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 122.46 Total: $122.46 doc: Receiot -06 Printed: 10 -13 -2010 5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 /?)/a - /N'i' Project; Ai /“ L.;■ic ill /4' 7. Type of Ins ection: ? CS,- e i-..«/ /i7' < -✓ �_ / is Address: 42 8 Lp-/ /17,7,-/-1 • c.. / Date Called: Special Instructions: Date Wanted:,L% Z /! / 1 /, /-- C.�tTr Requester: Phone No: 12 Approved per applicable codes. Corrections required -prior to approval. % . COMMENTS: r>� ,-1(%' ,Jo107V 4- ;V'? / CS,- e i-..«/ /i7' < -✓ �_ / is 47 kaei L, ✓N /.ey ti Date: l l � SPECTION FEE REQUIRED. Prior ja/next inspection. fee must be id at 6300 Southcenter Blv .. Suite O. Call to schedule reinspection. • INSPECTION NO. INSPECTION RECORD Retain a copy-with permit PERMIT Na CITY OF TUKWILA BUILDING DIVISION °"' 6.300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: , r i &t4u N Mal �} `� Type of Inspection: F tin Address: • t 2g4• MtLtTA 9 R� Date Called: Special Instructions: W ) t� -1 P bN1r - ,,l aG ov okx_ 'Y Date Wanted: 1Z- O- In a.m Requester: Phone No: o C 7 59(0- I 1 e Approved per applicable codes. Corrections required prior to approval. ❑ REIN 'ECTION FEE R QUIRED. 'rior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • if INSPECTION NO. INSPECTION RECORD Retain a copy with permit MO —o PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro' fit: t Typ : cdtk of Inspectio A dress Date Called: Special Instruc ions: Date Wanted ` rl ���_ l a a.m., p.m. Requester: Phone No: Approved per applicable codes. ll Corrections required prior to approval..'. COMMENTS: R INSPECTION FEE REQU tED. Prior to r ext inspection. fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. instry re Of raw Banditti Readings By: CJ Test Conditions: Date: 7)/o- / '-/' 1/3/2011 Air Outlet/Inlet Test Report Project: Highline Hospital - CT Scan Room Project Number: # Here System: HP - 1 Sup. - Area Served No. Type Size Design Cfm Preliminary Cfm Readings Final Cfm Percent Design Remarks A 8 C CT Scan Room 1 CD 10" -3 55 301 350 CT Scan Room 2 CD 10" 355 3T3 365 CT Scan Room 3 CD 10" 355 3 `8 C 37'1 1 1 CT Scan Room 4 CD 10" 355 343 370 5 Total: 141?-0 /L1Scl 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Total: i ''f 11-i5 �1 Ret. - Area Served No. Type Size Design Cfm Preliminary Cfm Readings Final Cfm Percent Design Remarks A 8 C C.1- i;,c.., ;,;1-1 1 R6- 67Li'5c " 635 s ,li 600 2(5- ay,,ic,, 635 ti� 5� g 1a 3 t�Ic. MA '50 '1Liq 310 1 1 4 5 Total: 141?-0 /L1Scl Remarks: 0)14.n:r.,vM o .4- ) i0 :i e4c(- • pp .Se�" 7y ivwES4- .3)0J R- Z' niA 'is a c cl c v 1 4 . o 1 5A- - RA- ; o3.4 Pos Readings By: CJ Test Conditions: Air Apparatus Test Report Project: Highline Hospital - CT Scan Room Project Number: # Here Date: 1/3/2011 System: HP - 1 Unit & Fan Data Motor & Drive Data Make Unit Type Model Number Serial Number Unit Location Unit Services Fan Type Fan Arrangement Fan Discharge Unit Discharge Unit Filter Data Unit Filter Data Trane Make & Frame HP & RPM Voltage & Phase F.L.A. & S.F. Motor Sheave Make Model No. & Bore Operating Diameter Fan Sheave Make Model No. & Bore Centerline Distance No. of Belts & Size Belt Adjustment AttrU4by^ 56 Roof Top Package Heat Pump 6 /745 t�SCOL WE 3 RDAOKLOcccoccaxv 6 a00 -`c730/tibU 3 lb; -VII 7 6 g L- 9-0-5.0/1.5 /<. 549 Roof 3 a/LM . n� CT Scan Room / V I--- 311 5A Forward Curve - Centrifugal 3.0 7. a DWDI g ro-- a.e, Horizontal 4L q 3 ft /9 Horizontal h ( ) c;10" )L 30" y 44 Plr 4►64 1 . AX 36 — AA • CA Performance Data Design Actual Static Pressure In Out Total Cfm Fan Rpm Return Air Cfm Outside Air Cfm Total Static Press. External S.P. Bhp (Approx.) Inlet Vane % Open VSD - Hz. Damper % Open n „tom ;,�a / Qa►,,, -., 14 175Q0' l H 59 Filter Dp Cooling Coil Dp Heating Coil Dp Dx Coil Dp Fan Total External Total Corrected F.L.A. O. A Full Flow Amps 0 . 0, ?-3 0. u 3 NA cf K3 DNA DNA DNA I")1 vim. (P 4-'9 DNA DNA DNA 150 3 P 0 0. Al 0.31 0. 03 NA 0.919 '& . 1, U 5. 5i r U . 19 0.75 J. 7 , !0. ;i.0 d Si( 0. 73 NA Amps - Actual VOLTS - Actual DNA a-- 99 4_a 7 DNA 6-1-' "d -7 g O 1 NA NA 01-, �5 Remarks: = Does Not Apply / NA = Not Accessible • EQUIPMENT START UP SHEET ... JOB NAME: JOB #: E O ' 7 DATE: / 'r ' UNIT #: MANUFACTURER: MODEL #: r 3 00 ,--#, -. ,t SERIAL #: 1 TYPE OF UNIT: - ,- -ia:?;,_' e:.4:' :,.. t_ nrill?. )(5 LISTED VOLTAGE: 2- `"��'' - -" PHASE: ,. MEASURED: A -B .2, A -C 2 "L' B -C `� `" of a WIRING CONNECTIONS CHECKED FOR TIGHTNESS Z1 TRANSFORMER SECONDARY VOLTAGE "" '�� FILTERS: QUANTITY: K-- SIZE: -;:`.'t 2 '1 TYPE: 7:2"1"4 '- CONDENSATE TRAP INSTALLED$ SHIPPING BLOCKS REMOVED i ECONOMIZER OPERATION CHECKED �i ENTHALPY SETTING A B tt✓i D A, VERIFY BELT TENSION & ALIGNMENT U' CHECK FAN ROTATION UV- -Z.0 '' A C ''' i�' B -C = �' INDOOR FAN: VOLTAGE LISTED PHASE. --= ACTUAL: A -B AMPERAGE LISTED ear ACTUAL: A B 2.' `'� C ` ''y :/ 1/ . MOTOR FRAME #• �' PULLEY SIZE: 1 / 1- HP / SPEED OR RPM -' --' / FAN SHAFT SIZE: �� '7 PULLEY SIZE: 1r'L�r i /` CENTER BETWEEN SHAFTS 7 i -'7 r j BELT SIZE. A x �'�G' QUANTITY / BEARINGS GREASED ❑ A.)14-- OUTDOOR FAN MEASURED VOLTAGE Cl MEASURED AMPERAGE COMPRESSOR: VOLTAGE LISTED -6"� PHASE: - ACTUAL: A -B �-� L! A -C B -C AMPERAGE LISTED: / ('- . ACTUAL: A +C • `S B l '' C ` REFRIGERANT TYPE: ?-410/1 AMOUNT IN SYSTEM f I c- SUCTION P ES./TEMP.: -r' / 3 '\ LIQUID PRES./TEMP • t 75 / 7 k:4 rt .4 '7 u SUPPLY AIR TEMP.: R.A. TEMP.: - O.D. TEMP.• RUNNING' GAS MANIFOLD PRESSURE LISTED: CONTROLS: BRAND: TYPE' PROGRAMMED YES NO MODEL #• ACCESS CODE. PERSON SCHOOLED' REMARKS: -Pz i i• f0.51— -�?f`. ' -.y ,l -7 �i.riil f MECHANIC'S NAME: TRUCK #: REVIEWED BY: White - Job File Canary - Project Manager Pink - Superintendent (ESUS0207) Collons + Smith Structural Engineers, Inc 485 Front Street, F -3 • Issaquah, WA 98027 p: (425) 369 -1101 • f: (425) 369 -1157 414,„ 44.4) Highline Medical Center Specialty Campus CT Replacement Structural Calculations Owner: Highline Medical Center 12844 Military Road South Tukwila, WA 98168 Architect: Northwest Architectural Company 2201 Sixth Avenue, Suite 1405 Seattle, WA 98121 Structural Engineer: John Smith, P.E., S.E. Job #: 10 -087 Date: September I5, 2010 frl to -10 REVIEWED CODE E COMPLIANCE Agort OvED DEC 10 2010 BUILD G of DIV Tukwila RECEIVED OCT 13 2010 PERMIT CENTER HMC CT Replacement Permit Submittal 9/14/2010 Page 2 of 34 Summary These calculations have been prepared to check the roof framing for the added weight of a roof - mounted, packaged heat pump unit. The heat pump weighs 600 pounds, along with an allocation of 500 pounds for the duct and in- linefilter box. Our findings are that the existing roof can safely support the load of the new unit. An added panel is required on the two joists supporting the unit. The added panel point requirements can be found on the project architectural drawings. Do to the light weight of the roof top package unit and the specification of fasteners every twelve inches around the perimeter of the curb, seismic anchorage is ok by inspection. A new 52" x 20" hole will be required in the existing concrete roof to accommodate the ductwork. A 4" square, tube steel strongback will be added to support the resulting unsupported corner at the new slab opening. HMC CT Replacement Permit Submittal 9/14/2010 Page 3 of 34 Project Architectural Drawings o\ E70STWO COMBUSTION AIR oUTIET - E%ISTINO NVAC UNIT oaSTWO NVAC UNIT oaSTINO EXHAUST VENT / / OHVAC PLAN - LEVEL 1 Scale: 1/4" = 1' -0" si 1. 2 71 ED - CD CO A n 2. Cn o (7 O -• cn —I W O U .Z7 3.� 3 CD 3 OWEST WING FIRST FLOOR LIFE/SAFETY PLAN Scala 1 /D' - Y -L• WOE DATA a, COSIOXXO 196 =MOM TOO a11O01a MO 100 0100CDMY OOOaOO® MOM 0 MOM ROM AMY WIT ISO.. TM FA Flo MOM O l∎ M MDOM Olt MOW pRa MA9.700l60, tr.4 MO MN 13 Oa 9WO7 MMOMMO MO OHO 10.rp., "f0r4.. " 'Eaoo�r �p1"ra�4mo°a A OO 00700 MD W IT 107171007 • Aw V. CODE PLUI GENERAL NOTES 1. O ROM WOG 1a aaaat .. L m[ •7000 T. MMIm-YR MO MUMS M MIME YO Offal R Inc • O. ASARCO p W ao AO 000MiT am uan Rahn a• `i. 7Z AZIL L IMO 00'1101770 on sofa In05 7. MOO10 R .4.7771 OA MOI W e Rol ml OO PLAN LEGEND uuIuN.7. Ia•�9a AAUO 1R w7a ia.+aii1'"ii'a' b I10V1a1 Ro XS ozumar p 1 mamma NIL DN11OmA �/1:O1�Oapp`pl.{��000, ynIpw�1"` rs+l°r o MIIl-IRWaaOR101W1L'Ma �tM Oo �[IOOIRtOafi OIKOOMOa x100 OI OKEY PLAN NOT TO SCALE FIFTH FLOOR LIFE/SAFETY PLAN 0 REVISIONS ARCHITECTURE �- 77147017 01.1 — i17)a,(0 WORM HMC CT Replacement Permit Submittal 9/14/2010 Page 7 of 34 N a M • • • _ .r "11= 11 =11:• 11 =- 11 =11 =1 ?11111.1.11.��.1 11.1111.1111 =1 11 =11 =11.I.1 n =jI .u- I- 11 =11 =1 = u =u =u. u =u= II =II: =IL = 11.1111 =11: =11-1 11. =11. 11=11 =1 lll'�II'�:I L .11: =11. - 11.11:11.111 Ilmil = 11 =11: ■II11 II: 1 -11= 41)11. ?111111: 11:11 II IL - 11:1.1 -II =11 11= =11 =11. 11�:11: 11==11. 41- 1.=11= 11=11 =11. 11= 11. °.IL °.11 1-411 =1 1= 11= 11.= 11= 11.- 11.= 11.= 11. -11= 11.='.'.11.= 11 =11: 11.= 1.= 11.= 11. =11= 11.-11- 11-11=11=M11=11 1 =11= 11-11= 11= 11. -11= 11-11= 11= 11.= 11 =11: IW 1=11=111=11=11=11=11=11=11=11=11=1 1=11 =11 -11- 11.-11 -11- 11=11-11`11 =11 -11. 11= 1 =11 -1L 11 =11 11=11 -u -11= 1 11 =1 1= 11= 11.= 11= 11= 11.= 11= 11.= 11= 11= 11 =11 =11 11= I =11= 11= 11= 11.= 11= 11 =11= 11 =11 1 =11 =11 11= 11 =II. ,11- 11-11.-11= 11 =11 =11. a11= 1 =11= 11 11 =11= 11- 11= 11 =11-= 11= : 11.X11.= 11= 11. =11.= 11=11= 11=11= 11.x.11 -11. HMC CT Replacement Submittall 0 10 Page 8 0?34 0 L /-7 V'' OP, itoin \01M 6t4-no X21. I )r 14 CR C'OP IscoA5 11.. 1 /...00 rrTO 01 \ \%7 • ( 1002> 641-4.1121 12M1 Pgr110/1) PAW .AIDR 1117 P19 MN W. 13.12 IVALUI JILJR A O PARTIAL BLDG SECTION a RAD ROOM 121 swatµ' -1-0' ' TYP CABLE THROUGH WALL 1 O PENETRATION FIRESTOP SYSTEM r ti" lv am1 .x711 .41 �n 1w m..An. o�sw 1.Rm NM RIMY C. LL MOO 1.1191 TYP PIPE OR CONDUIT THROUGH WALL 2 PENETRATION FIRESTOP SYSTEM C.. r.re "•' 1:2=1411."4 102=1.02=1:027T PARTIAL BLDG SECTION 51 RAD ROOM 121 OSHIELDING DETAIL JOINT a•' r.r-r RAN OR SECTION A� pp__ m von OCONDUIT ENTRANCE 51 SHIELDING O CONCRETE FLOOR INFILL D949 s-r-V CAL 1- Ia-1.4 PARTIAL BVKDN0swum INTERIOR DUALS • • REVISIONS iE ARCHITECTURE 3 m HMC CT Replacement Permit Submittal 9/14/2010 Page 10 of 34 Correspondence HMC CT Replacement PerPnagebiniOil 2 9/14/2010 Page 11 of 34 John Smith From: John Smith Sent: Tuesday, September 07, 2010 2:53 PM To: 'Steven Wescott' Cc: Jared Robillard Subject: RE: HMC CT Relocate - HP -1 and Project Schedule Ok. Thank you both. John Smith, PE, SE 1 Principal Collons + Smith Structural Engineers From: Steven Wescott [mailto :SWescott@NACARCHITECTURE.com] Sent: Tuesday, September 07, 2010 2:50 PM To: John Smith Cc: Jared Robillard Subject: FW: HMC CT Relocate - HP -1 and Project Schedule John, I just confirmed with Hargis that this is the correct unit. Heat Pump Unit weight is 600 lbs. Filter Box weight is 100 lbs. Roof Mounted Ductwork is 400 lbs. From: Jared Robillard [mailto:JaredR @Hargis.biz] Sent: Thursday, August 26, 2010 8:34 AM To: Steven Wescott Subject: FW: HMC CT Relocate - HP -1 and Project Schedule Steve, See below. Tha nks, Jared Robillard, PE, LEED® AP Mechanical HARGIS ENGINEERS 600 Stewart Street Suite 1000 Seattle, WA 98101 www.hargis.biz d 1 206.859.5383 o 1 206.448.3376 f 206.448.4450 From: Jared Robillard Sent: Tuesday, August 10, 2010 8:42 AM To: 'Dan Jardine'; 'SWescott@NACARCHITECTURE.com' Cc: Trevor Welch • Subject: HMC CT Relocate - HP -1 and Project Schedule Dan, 9/8/2010 Pertnnh At��jj WAiwent 9/14/2010 LL Page 12 of 34 Steve, See attached information for HP -1. I have noted the single point electrical connection requirements and total weight. An additional weight allowance of 100 lbs. should be included for the filter box and an allowance of 400 lbs should be included for roof mounted ductwork. Please communicate this information with the structural engineer. The budget for HP -1 is $5,400 for the unit itself, not including installation. What is the current schedule for the project? Is the draft schedule dated 7/22/10 still current? What date are we shooting for to complete the drawings? Do you have roof plan in .dwg format? Thanks, Jared Robillard, PE, LEED ®AP Mechanical HARGIS ENGINEERS 600 Stewart Street Suite 1000 Seattle, WA 98101 www.hargis.biz d J 206.859.5383 o 1206.448.3376 f J 206.448.4450 9/8/2010 HMC CT Replacement Pet -4140 ii 2 9/14/2010 Page 13 of 34 John Smith From: John Smith Sent: Wednesday, August 11, 2010 1:19 PM To: 'Dan Jardine' Cc: Steven Wescott; Jared Robillard Subject: RE: HMC CT Relocate - HP -1 and Project Schedule Ok. I did notice Jared's recommendations for consideration of added weights below. John Smith, PE, SE I Principal Colions + Smith Structural Engineers From: Dan Jardine [ mailto :djardine @NACARCHITECTURE.com] Sent: Tuesday, August 10, 2010 5:42 PM To: John Smith Cc: Steven Wescott; Jared Robillard Subject: FW: HMC CT Relocate - HP -1 and Project Schedule John — Here is some initial information about the rooftop unit for the CT Relocation. Don't proceed until we give you final information about the location and penetrations. esig- logo_nac Daniel C. Jardine, AIA, LEED AP, Principal www.nacarchitecture.com P 206 441 -4522 F 206 441 -7917 From: Jared Robillard [mailto:JaredR @Hargis.biz] Sent: Tuesday, August 10, 2010 8:42 AM To: Dan Jardine; Steven Wescott Cc: Trevor Welch Subject: HMC CT Relocate - HP -1 and Project Schedule Dan, Steve, See attached information for HP -1. I have noted the single point electrical connection requirements and total weight. An additional weight allowance of 100 lbs. should be included for the filter box and an allowance of 400 lbs should be included for roof mounted ductwork. Please communicate this information with the structural engineer. The budget for HP -1 is $5,400 for the unit itself, not including installation. What is the current schedule for the project? Is the draft schedule dated 7/22/10 still current? What date are we shooting for to complete the drawings? Do you have roof plan in .dwg format? Thanks, Jared Robillard, PE, LEED® AP 8/11/2010 1 Mechanical HARGIS ENGINEERS 600 Stewart Street Suite 1000 Seattle, WA 98101 www.hargis.biz d 1 206.859.5383 o 1 206.448.3376 f 1 206.448.4450 R/11/2010 HM CT Rplac Went PereggeaNAM L 9/14/2010 Page 14 of 34 HMC CT Replacement Permit Submittal 9/14/2010 Page 15 of 34 Rooftop Unit Data 'ELECTRICAL / GENERAL DATA HMC CT Replacement Permit Submittal 9/14/2010 Page 16 of 34 Electrical GENERAL (2m61 Model Unit Operdirg Voltage: Unit Primay Voltage Und Secondary Voltage: Lind Hertz: Una Phase: WSC048E 167 -256 208 230 60 3 Oversmed Motor MCA N'A WS: NA it N'A VN7H HEATER Heiler kW Rating : 13.1/1 Stage 2 MCA: 72 MFS 80 MCB 801100.0 679.9 480.0 SEER 13.0 Stardard Motor Field Irstdled O'ersiaed Motor Ovesized Nbtor Field IrstalledOverseEdMobr Mminum Circuit Anpadty: 27.5 MCA N'A MCA: MCA Maximum Fuse Sze: 40.0 WS: N'A MFS MFS: Maximum(HACFi) aicritBreaker. 400 MC@ N'A MC B: Mca INDOOR MOTOR Sardaid Motor Outsized Motor Field Instilled Oversized Motor Number: 1 Nunber: N/A IWmba: N/A Motor Speed (RRM): 1.0 Motor Speed (RRM): N/A Motor Speed (RRM): N/A 1-brsepowe: — Horsepower N/A I- brsecowa: WA • Phase: 3 Phase: N/A Phase: N/A FJI Load Amps 53 Full Load Amps N/A Frit Load Amps WA Locked Rota Amps: 322 Locked Rotor Amps: N/A Locked Rota Amps: WA COMPRESSOR arcuit1 /2 OUTDOOR MOTOR Nrmba: 1 Number. 1 Fbrsepowa: 3B Horsepower. 0.40 Phase: 3 Mdor Speed (RRM): 1075 Rated Load Amps 16.0 Phase: 3 Locked RotorAm{s: 91.0 Full LoadAnps: 2.5 Lacked RatorAmps 6.6 POJVER EXHAUST ACCESSORY 131 R LTERS REFRIGERANT (2) (Field Installed Power Exhaust) • Type R410 Phase: WA Type Throwaway Pbrsepowe : NIA Yes Factory Chage Moto Speed (RPM): N/A shed Nbmbe- 2 Cirut #1 9.41b Fill Load Amps: N/A Pecanmended 20'St30'k1" Chit f2 N/A Locked Rotor Amps: WA NOTES: 1. Maxi r um (I-IACR) Circuit Breaker sizing is for insta2dionsinthe thited States arty. 2 Refrigerart charge is an approxi mate vdue Fora rare predsevdue', see wit nameplate and service instudiars. 3 Vata does not include PoverExhatstAccessory. 4. Vd ue ircludes wersized motor. 5 Vdre does not induce Raver ExharstAcessory. fi EER is riled d ARI conditions and in acct dance wth DOE last procedures Page 4 e PACKAGED HEAT PUMP CORNER WEIGHT (Weight HMC CT Replacement Permit Submittal 9/14/2010 Page 17 of 34 INSTALLED ACCESSORIES NET WEIGHT DATA NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2 TO ESTIMATE SHIPPING WEIGHT ADD5 LBS TO NET WEIGHT. 3. BAS ICUNIT WEIGHT DOES NOT INCWDEACCESSORY WEIGHT. TO OBTAINTOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNT WEIGHT. 4. WEIGHTS FOR OPTIONS KDT USTED ARE >5 LBS. PACKAGED HEAT PUMP RIGGING AND CENTER OF GRAVITY Page 5 ACCESSORY WEIGHTS ECONOMIZER 26.0Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPB BAROMETRIC REUEF OVERSIZED MOTOR N/A BELT I3tIVE MOTOR POWER EXHAUST N/A HEATER 15.0Ib THROUGHT TI-E BASE ELECTRICAL ( FLOPS) 8.0 Ib UNT MOUNTEDCIRCUT BREAKER (FLOPS) UNT MOUNTED DISCONNECT (FIOPS) 5.O Ib POWERED CONVE NENCE OUTLET (F 0 PS) HNGED DOORS (FOPS) 10.0Ib HAIL GUARD SMOKE DETECTOR, SUPPLY / FETURN ROOF CURB 61.0Ib BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 181.0 Ib O 115.0 Ib (E) LENGHT (F) WIDTH 600.0 Ib 525D Ib 109.0 Ib 1 1119.0 Ib 29' 20" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2 TO ESTIMATE SHIPPING WEIGHT ADD5 LBS TO NET WEIGHT. 3. BAS ICUNIT WEIGHT DOES NOT INCWDEACCESSORY WEIGHT. TO OBTAINTOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNT WEIGHT. 4. WEIGHTS FOR OPTIONS KDT USTED ARE >5 LBS. PACKAGED HEAT PUMP RIGGING AND CENTER OF GRAVITY Page 5 HMC CT Replacement Permit Submittal 9/14/2010 Page 18 of 34 CLEARANCE F ROM TOP OF UNIT 72 CLEARANCE 36" CLEARANCE 36" CLEARANCE 37" PACKAGED COOLING CLEARANCE 40" 68 3/16" DOWNFLOW -ROOF OPENING 44 1/2" Page 6 HMC CT Replacement Permit Submittal 9/14/2010 Page 19 of 34 MAW ACCESSORY - RCOF TOP CURB 2215/16 149/16' 1" 1" 61 314 163/4" 1" 1713/16" 26 3/16' ACCESSORY -ROOF TOP CURB Page 7 WANE EVAPORATOR SECT°NACCESS PANEL CONDENSATE DRAN (ALT) 3/4'-14NPT DAI. HOLE 35/8' 14" - 91N" f-"- 151/2" -- L 4" 24" } RETURN ti 4 3118" 231a- rs \THROUGH THE BASE CONDENSATE UNIT CONTROL WARE 7/8" DA. HOLE SERVICE GAUGE PORT ACCESS 13/8 "DW. HOLE UNIT POWER WRE CONTROL AND COMPRESSOR ACCESS PANEL 2" ELECT KCAL CONNECTION (SINGLE POINT PON.ER WHEN HEAT INSTALLED) ISOMETRIC- PACKAGED COOUNG THROUGH THE BASE ELECTRICAL (REQURES FACTORY INSTALLATION) 2 13/16" J 47/8' -'- 5 1 /16• --t DOWN FLOW - PEN ETRATION 7 w.. 1 7 RETURN w%; 1 SLPPLY 143/4'. 171/4" CONDENSATE 697/8" 87/8 "r - 131/4' H OR IZ ON TAL- PENETRATION bb 311116" 231/4" 43/4" 33/16" AIRFLOW 361/4" M1 0 IIHII!1 4 U4" 5 916" 758" RIGHT - PACKAGED COOLING HMC CT Replacement Permit Submittal 9/14/2010 Page 20 of 34 HORIZONTAL AIR FLOW Page 1 171/4" CONDENSATE 697/8" 87/8 "r - 131/4' H OR IZ ON TAL- PENETRATION bb 311116" 231/4" 43/4" 33/16" AIRFLOW 361/4" M1 0 IIHII!1 4 U4" 5 916" 758" RIGHT - PACKAGED COOLING HMC CT Replacement Permit Submittal 9/14/2010 Page 20 of 34 HORIZONTAL AIR FLOW Page 1 4 U4" 5 916" 758" RIGHT - PACKAGED COOLING HMC CT Replacement Permit Submittal 9/14/2010 Page 20 of 34 HORIZONTAL AIR FLOW Page 1 HMC CT Replacement Permit Submittal 9/14/2010 Page 21 of 34 Check Existing Joist for Added Weight of Unit f fix: Via. x ?6ei collons smith structural engineers 485 Front Steet N • Suite F -3 Issaquah, WA 98027 p: 425.369.1101 • E 425.369.1157 HMC CT Replacement Permit Submittal 9/14/2010 Page 23 of 34 :3h?!' dares �1I11 L1.17 ,�J,� UM" Ovr 1 /4“ Por- PUGt k 19 - , 412 (5) a- 25* =, d71 /kip, bik 're , ( / ,GAS Pf • s961 6)1011- olesi ediv s/ww eageAr zr- • dr (tif:s) 4/0 Avdo 005 SNIT • Zi'v -/Jet ' � �l /41) "J' /off �I�v cpllons + smith structural engineers '485 Front Steet N • Suite F -3 Issaquah, WA 98027 p:425.369.1101 • f: 425.369.1157 HMC CT Replacement Permit Submittal 9/14/2010 Page 24 of 34 14-1-14- f/-ts--/ 4)/lam, /1&=. a 7/ A M/SleC/7011 qkAVJ /0¢ tS OsX del i71l uw' HMC CT Replacement Permit Submittal STANDARD LOAD TABLE OPEN WEB STEEL JOISTS, H. SERIES Based on Allowab ,/a9trr soc#f 0,000 PSI Adopted by the Steel Joist Institute and American Institute of Steel Construction Inc , Oc ober 1, 1974 The black figures in the following table give the TOTAL-safe uniformly distributed load- carrying capacities, in pounds per linear foot, of H- Series Steel Joists. The weight of DEAD loads, including the joists, must be deducted to determine the LIVE load- carrying capacities of the joists. ...The load table may be_ used for_parall_ei.chordjoists installed to a maximum slope of Y2 inch per foot. The figures shown in blue in this load -table are the LIVE loads per linear foot of joist which will produce an approxi- mate deflection of 1/360 of the span. LIVE loads which will produce a deflection of 1/240 of the span may. be... obtained by multiplying the figures in blue by 1.5. In no case shall the total load capacity of the joists be exceeded.•" Tests on steel joists designed in accordance with the Standard Specifications have demonstrated that the Stan- dard Load Tables are applicable for concentrated top chord loadings (such_ as are developed in bulb -tee roof construc- tion) when the sum of the equal concentrated top chord loadings does not exceed the allowable uniform loading for the joist type and span and the loads are placed at spacings not exceeding 33" along the top chord. LOADS ABOVE THE COLORED LINES ARE GOVERNED BY SHEAR. Joist Designation 8H3 10113 10114 12113 12114 12115 12H6 H3 14H4 14H 14116 14H7 16114 16H5 16116 16117 16118 Nominal *Depth (in.) 8 10 10 12 12. 12 12 14 14 4 14 14 16 16 16 16 16 Resist. Moment (In: lbs.) 91,000 116,000 148,000 140,000 180,000 222,000 260,000 165,000 212,000 259,000 307,000 369,000 221,000 289,000 344,000 413,000 478,000 Max. End React. (lbs.) 2400 2500 2800 2800 3200 3600 3900 3200 3500 3800 4200 4600 3800 4300 4600 4900 5200 tApprox. Wt. (Ibs. /ft.) 5.0 5.0 6.1 5.2 6.2 7.1 8.2 5.5 6.5 7.4 8.6 10.0 6.6 7.8 8.6 10.3 11.4 Span in Feet 1 8 600 9 . 533 10 • 480 460 500 560 11 436 345 455. 509 12 400 266 417 467 467 533 600 650 13 359 209 385 337 431 417 431 492 554 600 14 310 167 357 270 400 334 400 393 457 514 557 457 500 543 600 657 15 270 -136 333 219 . 373 - 271 373 320 427 418 480 520 427 467 507 560 613 16 232 112 302 181 350 223 350 264 400 345 450 . 404 488 480 400 366 438 475 525 575 475 538 575 613 650 17 268 151 329 186 323 220 376 287 424 .337 459 400 • 376 305, 412 398 447 494 541 447 506 541 576 612 18 239 127 305 157 288 185 356 242 400 284 433 337 340 257 389 336 422 393 467 511 422 413 478 511 544 578 19 214 108 273 133 259 157 332 206 379 241 411 286 305 218 368 285 400 334 442 399 484 470 400 351 453 432 484 516 547 20 193 92 247 114 233 135 300 177 360 207 390 246 275 187 350 245 380 287 420 342 460 403 368 301 430 370 460 ' 437 490 520 21 212 117 272 152 336 179 371 212 249 162 320 212 362 248 400 295 438 348 334 260 410 320 438 377 467 454 495 22 193 101 248 133 306 155 355 185 227 141 292 13.4 345 215 382 257 418 302 304 226 391 278 418 328 445 395 473 454 23 176 89 227 116 280 136 328 162 208 123 267 161 326 189 365 225 400 265 279 198 364 243 400 287 426 346 452 398 24 162 78 208 102 257 120 301 142 191 108 245 142 300 166 350 198 383 233 256 174 334 214 383 253 408 304 433 .353 25 176 96 226 125 276 147 327 175 368 206 236 154 308 190 367 224 392 269 416 310 26 163 209 255 1056 354 3 137 285 69 199 377 275 27 151 194 99 237 281 164 202 264 315 363 246 28 140 68 180 89 220 104 261 125 314 147 188 110 246 135 293 159 350 192 371 220 29 . 175 99 229 121 273 143 327 172 359 198 30 164 89 .214 110 255 129 306 156 347 179 31 153 81 200 99 239 117 287 141 332 162 32 144 74 188 90 224 107 269 128 311 • 148 See page 20 for notes 19 to-14)L01, wo-ov 46124,14 eron4 AM' 01)12-5 7- *VOX 0 /1011445 thTh @) */'td slt&VA/eag 4ar- Meg* 64/wig% c 1114 1,44 IIRAMIll i1 7'V 111111ffirAill /11111K_ I 14 vt, V1, OA' Th-De&14- 111-4 14"' • bei117/116/AftegG, cirCre TrP 4 eT04.1 4/0/V Viae ceblio4.5/vie. 050n) "1/117- 41* if 05 Axis N, x/Xi//e, IV d-ei-&s HMC CT Replacement Permit Submittal 9/14/2010 Page 27 of 34 New Concrete Roof Opening csollons + smith structural engineers .485 Front Steet N • Suite F•3 Issaquah, WA 98027 p: 425.369.1101 • f: 425.369.1157 HMC CT Replacement Permit Submittal 9/14/2010 Page 28 of 34 M/C -pey////t/ vv 40z (i) .Rio 4,41 )74 4rno/e , O (400 s- 5‘1Prao 08s 54 /.S'-- ///4 p / id ( /,r) f/ T ,.4 r bq/zi dmf r-, /) ii�l5 l5 1J1� ft6477Vf 4l�'�i �� ! S NaT ��UOarr�r/ �a� /&M- #0n 47Xe4 92/m NW/I ff/e5 OP -T7 4 m54. 460- t(1..= q4.41 t 1417 ri/f4./ "1/4-)::,,96, IS- S met= Oclfil- A9nt x/93 m ¢ Ofen %n L es6 4'4 ;4-v toss. by ,40 /-�10 t,Us _ .mzr sozr coilons + smith structural engineers .485 Front Steet N • Suite F -3 Issaquah, WA 98027 p: 425.369.1101 f: 425.369.1157 CT Replacement Permit Submittal 9/14/2010 Page 29 of 34 y�l = , 097 (yt•/ /,o q / fr- HMC 41/ la 5 �tj yIIt S1./h°ites RP, / AC° 11,04-1 to "tviru, 10\ 4114. /Pt/ VA" 0.-rim Ituoi Ittiew ev elY~E.,0 0 • - HMC CT Replacement Permit Submittal 3PP 10 4 144 64 bp^ (moth- et 10) #1,41-911too- is 011444"0 .re 64 t# erws IA" 172- HMC CT Replacement Permit Submittal 9/14/2010 Page 31 of 34 Existing Building Structural Drawings 4"0 VLSI. • el 1 • •vm.....e tau }coal- Ned.r4 micrPern4 oP r i ee4Ls-. •-• ttt Gig/P.4C. UV Gem, wo.4.14 D b vi i •fer,A. .4■0 i 4. 8).) c • i 0 w _. —,....... .; • I El-, --L. ---tt.it.11-%-„;; 1 pu4.,.......0 . es-ezoLe • .• i r■ 1* I'l fil 9 0, ,. ,... N t,. -„, I-. -"" C.M115,14.. O. C.....,.... M.O.,. ...--•■•••Jo ‹),e- Ala t. • _ --`41 .1'• SCfl7J £2 3 — ir'.92-1L'"" 12ZW.1157 • 'It — JYPICAL ..U.I i:.'' 1 I 55.C-1,101,1 5 SEC-Te-4 F /V&1. .4 0., • • TIJ J 4•% : Ts! s: • • ▪ i -r.• eir15-1-,-____(!) i a 2-▪ 1 . g: 1 I T 1 i !. I I • !.'ik' •• I - - ■1 . , , .' - 1 ■ • • . ll -,-.-•-,:-.:i ; - 1 , -r- i 2k 1 ) . " 1 I S • ! .. 1 :- :::1: 1,7-•.1:", eouvr na 1, • IICE•44r• fe.491,444441, • 0.0,v6.4.t FLOW. toptV,Ale• Ver4,2 • , • -1; AN, 12! '41 I 1 j rig5T PL-._,1b1 , ---.- , --- vr.to,....-. 44.7•4444 ••, (I' < PI- s 9/- ,44-4441; Pler-VMStai, • 4 raw:p.(4 7 40. oe ('MI) t- gel . tecnow 14‘,/tti• 4446.4•6e,44711 LI TrIlt;'S ,7• 44•4‘G,A119 re. — pe.anly, MP C.4 WU." Uote 994 •:9414 999.7 cflQtJi ecno • $1.41,9 • 1 I t i . • • ii F.: Ve. .. _ . • _1 A ‘• ...1 ! ':;.%13I::,:,`:•2-.... - /tieltiV6' ■ . r !!" . . TTFICAL DETAIL FOP, J 015T ...1.).P.PSei5..AT-LPN..C3kLE. W.611.-i. 1 i 1 &0 1 GO 5 t313012:31E7aC311:31:71 1111EMI21 4t7— 04 •ja EMIT 11151071 EDUI-E Immo. .1.4 111.91. • PRECAST P LAW K SCHEDULE E PLAT 1•444 14.• •••=119.:11▪ 9 11499‘19. ts..99.4 i•Wt4.w14 or 0 . an • TYPICAL. PLA-1k al.4.4 4,4,31 \ Oa. - CD - - I mle.ieittg 04.LATER th • ,1R 7 I1 1T ; 51' 63� . H,on -. 1 r �,s -a •sv 'i Jilt ' L v,.5.55 L k.. 9M . I li a j¢w • -If�. ,s ia•li J n,•r °.& ' r., ,ue. now . ',veva es m3.8° \• / d" fy011735 .. ..p.....v..i•�,,,c i i C 1, �i �< a s•.......• 41.1+12: Al It.' O -- ---- 'fi:;K: gg 11 l ? t Z ...1,,,,,,...,,....";',—;= i -'r_ W G. r 1 ia.. ,. IY r 4.0,........-..,.. mac.,.....51,14,..1.72."10 4 i a N NOr1739 M1131:: .Otl •.,Y W NOIJ.7 3 w 01 3 aHr 0 mfr) • YfIIMuu1R,1.•.pu.Y.{W 1,1 n.4.0 1101 w,..u,wultA 1114 Jwx n.—, 4 .n. pro, ••I Di A • 51.1n, • „ 71. i w�l,R P.••R nlfn, N A,I•A wu w1 P.... 10.1 011 Yp.11 001.WM,110,I,P1, yIn • W . nw% •l, 1.00 PIp pn»r P• w 101.1 • 1..0 ,...w,I 08..11 t40 Yry•„w •. Px •I•xq w, 4.•4Ir anMV,; 1.5•x1 • 4 •,I4••0 , Itw• 541.414 pp 1 ,A YPU4 qI 4 P0.1.1. 1(• Y,•u.■ .11 :1 1•. a —414 . .1.•. uw..Hwl,w, 4 5 Pp.1 w P 4x4, 1n �• Pr i P • " 11.1� .'10 uu0uw,p '10w11.01 •&•15.151.. l nn41 �� .,w .N•, , Jt,. • �• I � , 1n ••S IsI. w? 1t•T• wwx M r. 1: p w 41 P1 w M R M P ,ni• WPN 101 10, 051 Y"a • +igvn,w n M shim. IN �• , •y .a ix4 'Tr: 1R nmtno, • >ila • w d.P 4011 n nn'!,LPn4 13 P:.. iWn tLli •.Wnn nn.:i 'srrl a 10..•.10 , w. bNJ� IA ' 410.• 1•P•m• W uPIP,• T n w11yyP , 11.0 ..P 4a • . w •unw m• r,. •n , 1,0110' •W PI? w P.w,, Iwai w Y).1� NF„'; Mi1P': Itw1 YI51 p•f• LYf wPI3oNL>.�. l'Y •nN•S•Pi 11.? 10101. wnu:,4' 2011,,•wPn. un•,g•�y {•1.WPw. vin x10101 'IY •e •.'1M 'Y•'M It4:'1•••I1`j ••.P•nJlr .ISLS •lMWY1f r {LAOISa� d NCi1iT�S P-• NQLL0 d NOI.9 NOI1T9 Aso i7 ,t'r 1l ,all of m 5 lit t a ..I, ,4 w.a. PlYlow•. ,. wn,.e: w�. w.'wl •+.•1� ..w'.. wM .nn,x�i•�1:•• •YV•n Al �:N a, MJ i Pn"IM` M 'Sr:�fi•Pi 44M�,M IW oN Iti,41,•„;,=•MPi•�•nu. I , YuI• .,n. r u, LtM ,uwn mwfwl llaaaLy)blm onSLlylY f •4wt• ^•rf.xP1 ...•14•�••1�..p,1w1� lli•• w•• Ili p1uN�t•RP•N 11I`WII. 1fi1w -" •x tiw1;n W� •nt.Y u�nJ uM i • • ity fr r o ��_' Jim Haggerton, Mayor Departine - t of Community Development Jack Pace, Director October 27, 2010 Rick Zehner McKinstry 505 3rd Av S Seattle, WA 98134 RE: Correction Letter #1 Mechanical Permit Application Number M10 -146 Highline Medical Center —12844 Military Rd S Dear Mr. Zehner, This letter is to inform you of corrections that must be addressed before your mechanical permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johnson at 206 433 -7163 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Bill Rambo Permit Technician encl File: M10 -146 J�r W:\Permit Center \Correction Letters \2010\MI0 -146 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: October 18, 2010 Project Name: Highline Medical Center Permit #: M10 -146 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The engineering specifies bolting and welding of additional structural steel members. Provide a special inspection table that specifies all special inspections for this project. 2. The code data on the cover sheet references correct building codes, however on M 0.2 Non- structural Mechanical Component Notes, the outdated 2006 Building code notes are referenced. Revise the notes to reference the current 2009 codes with changes to the code language to be consistent with the current building codes. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. 1110ektiMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -146 DATE: 11/24/10 PROJECT NAME: HIGHLINE MEDICAL CENTER SITE ADDRESS: 12844 MILITARY RD S Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEP RTMENTS:�I j l ing Division Public Works 4 n Vv Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 11/30/10 Not Applicable U Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route IF:f REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 12/28/10 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • • �, '��: - COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -146 DATE: 10 -13 -10 PROJECT NAME: HIGHLINE MEDICAL CENTER SITE ADDRESS: 12844 MILITARY RD S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPAR MEN S: iter1,61 Building 'vision Public Works Ay\ NA-- Fire Prevention Structural otif,--( 0 El Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -14 -10 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions DUE DATE: 11-11-10 Not Approved (attach comments) X Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: t0-4).-.}-1 0 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Ch of Tukwila Steven 11 A9ullet, Aicn'or Department of Community Development 6300 Southcenter Boulevard, Suite #•100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -131 -3665 Web site: http:t/wu'w.ci.tukwikr.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center, Revisions• will not he accepted throng/ the snail, fax, etc. Mio- 14( Date: Plan Check/Permit Number: = ❑ Response to Incomplete Letter # Response to Correction Letter # 1 [1 Revision # after Permit is Issued 17 Revision requested by a City Building Inspector or Plans Examiner Project Nance: Highline Medical Center Project Address: 12844 Military Rd S ^rry n c LA NOV 24 2010 ''EF M17 CENTER Contact Person: VW- 1-6 11 f" Phone Number: 7 ' Q 2- Summary of Revision: CADwavv►.e. -t- t Draw Am % B$ I ka, la�een 11 C4 ev\ e.YC,1 'u Lt rc.1 k Ls " SAC. -icA iv∎spec,- JAS C+nncA ovAcAvvrc r2c�wr�rerw� eM'- % rL T3r Sheet Nuinber(s): • "Cloud" or highlight all areas of revision including skate of revision Received at the City of Tukwila Permit Center by: reS -eAr e 4L2 ciArY?N k `21xJ1 2C�l.i i cA. Tut. 1n earvic U+nc1 'l u `1c� ti1e ciocte , Entered in Permits Plus on Il�� 1J \applicat ions \0 ,1.5- aplaliaations can Iii Created: 8-13-2004 Revised: revision sulmhi0al Contractors or Tradespeople P ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MCKINSTRY CO LLC UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State WA Expiration Date 3/16/2012 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JLLYDIG+ MCKINSTRY LLC Construction Contractor General Unused 4/13/2010 4/13/2012 Active WESTVI'121RF WESTVENT INC Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN "372ND MCKINSTRY CO Construction Contractor General Unused 8/20/1963 1/2/2008 Re Licensed Business Owner Information Name Role Effective Date Expiration Date PEDERSEN, JAMIE D Agent 03/16/2006 Bond Amount ALLEN, DEAN CHARLES Partner /Member 03/16/2006 929511574 MOORE, DOUGLAS JAMES Partner /Member 03/16/2006 _ ALLEN, DAVID EDWARD Partner /Member 03/16/2006 TRAVELERS CAS 8 SURETY CO TEPLICKY, JOSEPH WILLIAM Partner /Member 03/16/2006 03/01/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 WESTERN SURETY CO 929511574 09/09/2010 Until Cancelled _ $12,000.0009/02 /2010 1 TRAVELERS CAS 8 SURETY CO 104702039 01/03/2006 Until Cancelled 03/01/2011 $12,000.0003/16 /2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009 01/31/2011 _ $2,000,000.00 12/07/2009 2 ZURICH AMERICAN INS CO CP03999903 01/31/2008 01/31/2009 $2,000,000.00 01/31/2008 1 CHARTER OAK FIRE INS CO DTC052D7193C0F07 01/31/2006 01/31/2009 $1,000,000.00 01/08/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 12/13/2010 CT EQUIPMENT REPLACEMENT, ROOM 164 HIGHLINE SPECIALTY CAMPUS TUKWILA, WASHINGTON OWNER CONTACT: DIANNE MUNROE ARCHITECT CONTACT: STEVEN WESCOTT, AIA STRUCTURAL CONTACT: JOHN SMITH, P.E., S.E. MECHANICAL CONTACT: JARED ROBILLARD ELECTRICAL CONTACT: DOUG FORSLUND PROJECT INFORMATION PROJECT DESCRIPTION: JOB SITE ADDRESS: TAX PARCEL NUMBER: ZONING CLASSIFICATION: PERMITTING AUTHORITY: HIGHLINE MEDICAL CENTER 16251 SYLVESTER ROAD SW„ BURIEN, WA 98166 NACIARCHITECTURE 2201 SIXTH AVENUE, SUITE 1405, SEATTLE, WA 98121 (206) 441 -4522 COLLONS & SMITH STRUCTURAL ENGINEERS 485 FRONT STREET NORTH, SUITE F -3, ISSAQUAH, WA 98027 (425) 369 -1101 HARGIS 600 STEWART STREET, SUITE 1000, SEATTLE, WA 98101 (206) 448 -3376 HARGIS 600 STEWART STREET, SUITE 1000, SEATTLE, WA 98101 (206) 448 -3376 INTERIOR REMODELING TO THE FIRST FLOOR OF THE WEST WING FOR DIAGNOSTIC IMAGING EQUIPMENT REPLACEMENT. APPLICATION FOR ALTERATIONS TO MECHANICAL, ELECTRICAL AND FIRE PROTECTION SYSTEMS WILL BE UNDER SEPARATE PERMIT. 12844 MILITARY ROAD SOUTH TUKWILA, WASHINGTON 98168 162 - 304 -9001 0 - OFFICE CITY OF TUKWILA DEPARTMENT OF HEALTH LEGAL DESCRIPTION IN THE COUNTY OF KING, STATE OF WASHINGTON: SEPARATE PER PAT ,iT REQUIRED FOR: 0 Mechanical Electrical Plumbing Gas Piping City of Tukwila • BUILDING DIVISION THAT PORTION OF THE NORTH ONE -HALF OF THE NORTH NORTHEAST ONE- QUARTER OF SECTION 16, TWP, 23N, RANGE 4E, W.M., IN KING COUNTY, WASHINGTON, LYING EASTERLY OF MILITARY ROAD, EXCEPT THAT PORTION OF THE NORTHEAST ONE- QUARTER OF THE NORTHEAST ONE- QUARTER OF SECTION 16, TWP, 23N RANGE 4E, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: 1. BEGINNING AT A POINT ON THE SOUTH LINE OF THE NORTHEAST 1/4 OF THE NORTHEAST 1/4 OF SAID SECTION 16, DISTANT EAST 561 FEET FROM THE SOUTHWEST CORNER THEREOF; THENCE NORTH, AT RIGHT ANGLES 184 FEET, THENCE WEST ON A LINE PARALLEL WITH SOUTH LINE OF SAID SUBDIVISION 225 FEET; THENCE NORTH AT RIGHT ANGLES 210 FEET; THENCE WEST ON A LINE PARALLEL WITH SOUTH LINE OF SAID SUBDIVISION TO THE EASTERLY LINE OF MIUTARY ROAD; THENCE SOUTHERLY ALONG SAID EASTERLY LINE OF MIUTARY ROAD TO AND INTERSECTING WITH THE SOUTH LINE OF SAID SUBDIVISION TO POINT OF BEGINNING. AND EXCEPT THAT PORTION OF THE NORTHEAST 1/4 OF THE NORTHEAST 1/4 OF SECTION 16, TWP, 23N, RANGE 4E, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: 2. BEGINNING AT THE INTERSECTION OF THE SOUTH UNE OF THE NORTH 160 FEET OF SAID SUBDIVISION WITH THE EASTERLY MARGIN OF MILITARY ROAD; THENCE EASTERLY ALONG SAID SOUTH LINE 200 FEET; THENCE NORTHERLY AT RIGHT ANGLES 160 FEET TO THE NORTH LINE OF SAID SUBDIVISION; THENCE WESTERLY ALONG SAID NORTH LINE TO THE EASTERLY LINE OF SAID MILITARY ROAD; THENCE SOUTHERLY ALONG SAID EASTERLY LINE TO THE POINT OF BEGINNING; EXCEPT THAT PORTION IF ANY, CONVEYED TO KING COUNTY FOR 128TH STREET, BY DEED RECORDED UNDER AUDITOR'S FILE NO.5274608. kitg tit 4r k' Roo • rydale Mac W.3$rmgtcn•. ►rter° al r ter, VICINITY MAP TRUE NO SCALE NORTH HIGHLINE SPECIALTY CAMPUS PROJECT LOCATION. West Wing, 1st Floor Tenant Improvement FILE: C py Permit No. Plan review approval is subject to errors and omissions. Approval of construction document does not authorize the violation of any adopted code or ordinance. Receipt c I approved Field Copy and conditions is aclmowledged: BY Date:„..4„,4,,g/dx,„„...,„mwswomsmi, City h► Of'T�cwila BUILDING DIVISION \‘ EXTERIOR MATERIAL STORAGE ARE MATERIAL DELI AT FIRST FLOOR + REVIEWED FOR CODE COMPLIANCE PPrInVE DEC 1 0 2010 City' 0 BUILDING PLAN NORTH la ISION LOCATION MAP NO SCALE ARCHITECTURAL SYMBOLS L1 149B R149B C) SIM ROOM NAME tot 0 GRID LINE DOOR IDENTIFICATION RELITE IDENTIFICATION REVISION MATCH LINE Shaded area is side considered WORK POINT, DATUM POINT, CONTROL POINT DETAIL Upper mark denotes drawing number Lower mark denotes sheet PARTIAL BUILDING SECTION INTERIOR ELEVATION Elevation number denoted in arrow Sheet number denoted in box ROOM IDENTIFICATION CODED NOTE WALL TYPE DASHED LINE Used to denote items hidden, overhead, not in contract (NIC), or to be removed BREAK LINE Material to continue CENTER LINE, GRID LINE PROPERTY LINE ARCHITECTURAL MATERIALS DETAIL INDICATIONS ACOUSTIC TILE OR BOARD ROOFING BRICK CAULKING OR SEALANT CERAMIC TILE CONCRETE PRECAST CONCRETE CONCRETE MASONRY UNIT RIVENEUMININEIRSIMENIME •-1 m Ii / UJ,i \I ►Z� EARTH /FINISH GRADE GLASS GRAVEL GYPSUM BOARD INSULATION, BATT INSULATION, RIGID METAL MORTAR, PLASTER, SAND PLYWOOD WOOD, FINISH WOOD FRAMING Continuous member �- WOOD FRAMING Interrupted member PLAN INDICATIONS EXISTING WALL NEW STUD WALL NEW CONCRETE MASONRY UNIT NEW CONCRETE NEW BRICK REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may Include additional plan review fees. ARCHITECTURAL ABBREVIATIONS 1 0 # T A/C ACOUS AD ADJ ADJT AFF AL ALT ANC APPROX ARCH AUTO BD BET BITUM BLDG BLK BLKG BM BOTT BRG BUR CAB CB CER CG CJ CLG CLKG CLO CLG CLR CMU COL CONC CONST CONT CORR CPT CT CTR DBL DEMO DF DIA DIAG DIM DP DR DN and angle at centerline channel diameter or round plate pound or number tee air conditioning acoustical area drain adjustable adjacent above finished floor aluminum altemate anchor(age) approximate architectural automatic board between bituminous building block blocking beam bottom bearing built up roof cabinet catch basin, ceramic corner guard control joint ceiling calking closet ceiling clear concrete masonry unit column concrete construction continuous corridor carpet ceramic tile center double demolish, demolition drinking fountain diameter diagonal dimension dampproof(ing) door down EA EJ EL ELEC ELEV EQ EQUIP EW EWC EXH EXIST EXP EXT FA FAB FD FE FEC FEC -S FF FFL FIN FL FLG FLUOR FOC FOF FOM FOS FOSH FP FT GA GALV GL GLZ GMU GYP BD HC HD HDWD HORIZ HT HVAC ID INCL INFO INSUL INT L LAB LAM LKR LT LV JT each expansion joint elevation electrical elevator equal equipment eyewash electric water cooler exhaust existing expansion exterior fire alarm fabricate floor drain fire extinguisher fire extinguisher cabinet (recessed) fire extinguisher cabinet (semi- recessed) factory finish finished floor line finish floor flooring fluorescent face of concrete face of finish face of masonry face of studs face of sheathing fireproof foot, feet gauge galvanized glass glazing glazed masonry unit gypsum board handicap (accessible) head hardwood horizontal height heating /ventilating /air- conditioning inside diameter (dim.) include information insulation interior length, long laboratory laminate locker Tight, left louver joint MACH MATL MAX MC MECH MEZZ MFR MIN MIR MISC MO MT(D) MTL MUL machine material maximum medicine cabinet mechanical mezzanine manufacturer minimum mirror miscellaneous masonry opening mount(ed) metal mullion N north NIC not in contract NO OR # number NOM nominal NTS not to scale OA OC OD OFCI OFOI OH OHD OPNG OPP ORIG PC PERF PERP PLAM PL PLAS PLYWD PNL PR PREFAB PREFIN PROJ PT PTD PTDR PTN PTR over -all on center outside diameter (dim.) other furnished contractor installed other furnished owner installed overhead door opening opposite original pre -cast perforated perpendicular plastic laminate plate plaster plywood panel pair prefabricate(d) preflnish(ed) project point, paint paper towel combination dispenser & partition paper towel receptacle dispenser paper towel receptacle R riser, radius RCP reflected ceiling REBAR reinforcing bar RECD received REF reference RF roof REFR refrigerator RO rough opening RM room REQD required plan S south SCD seat cover dispenser SD soap dispenser SECT section SHR shower SHT sheet SHTG sheeting SIM similar SND sanitary napkin dispenser SNR sanitary napkin receptacle SPEC specification SQ square SSK service sink SS stainless steel STD standard STL steel STOR storage STRUCT structural SYS system TB towel bar, tackboard TC top of curb TEL telephone TEMP temporary TF top of footing THK thick THRU through TM top of masonry TP top of pavement TPD toilet paper dispenser TS tube steel TV television TVB television bracket TW top of wall TYP typical UNFIN unfinished UNO unless noted otherwise UR urinal VB vapor barrier VCT vinyl composition tile VER verify VERT vertical VEST vestibule VOL volume W west, wide, width W/ with WB whiteboard WC water closet WD wood WDW window W/O WP WSCT WS without waterproof wainscot weather stripping WT weight WTR water INDEX OF DRAWINGS GENERAL 4 G0.1 PROJECT COVER SHEE tf. G1.1 FIRST FLOOR LIFE/SAF PLAN 5 ARCHITECTURAL A2.1 FIRST FLOOR DEMOLITION PLAN A3.1 FIRST FLOOR PLAN, WALL TYPES, SCHEDU A3.2 ROOF PLAN & EXTERIOR DETAILS A5.1 PARTIAL STRUCTURAL A5.2 PARTIAL BUI A7.1 INT AN & STRUCTURAL DETAILS ECTIONS & INTERIOR DETAILS ELEVATIONS, CASEWORK & INTERIOR DETAILS IRST FLOOR REFLECTED CEILING PLAN & CEILING DETAILS MECHANICAL MO.1 MECHANICAL LEGEND MO.2 GENERAL NOTES AND ABBREVIATIONS MO.3 MECHANICAL SPECIFICATIONS MO.4 MECHANICAL SPECIFICATIONS MO.5 MECHANICAL SPECIFICATIONS M0.6 MECHANICAL SPECIFICATIONS MO.7 MECHANICAL EQUIPMENT SCHEDULES it M1.3 FIRST FLOOR HVAC DEMOLITION PLAN M3.1 -= FIRST FLOOR HVAC PLAN M6.1 MECHANICAL ROOF PLAN M9.1 MECHANICAL DETAILS ELECTRICAL E0.1 ELECTRICAL LEGEND E0.2 ELECTRICAL SPECIFICATIONS ED1.1 ELECTRICAL DEMOLITION PLAN E2.1 PARTIAL FIRST FLOOR LIGHTING PLAN E3.1 PARTIAL FIRST FLOOR POWER & SYS ' MS PLAN E3.2 PARTIAL ROOF POWER PLAN E9.1 ELECTRICAL ONE -LINE DIAGRA GE MEDICAL INSTALLATION FOR INFORMATION ON C1 SITE READiNE Al EQUIPMEN AYOUT SI STRUCT . L- LAYOUT S2 STR ' URAL DETAILS CTRICAL LAYOUT ELECTRICAL SPECIFICATIONS ELECTRICAL DETAILS. EQUIPMENT DETAILS WING RECEIVED • OCT 13 2010 PERMIT CENTER 2 PROJECT COVER SHEET REVISIONS 5785 GIST RED RC ,1J CT D I L C. 'ARDINE STATE IF WASHINGTON ( ) z O z 5 J >1. CO 0 �--- f-. 0 z_ W 2 W a.. U -J V 1 w taId I- G� � 4.. R YitNM z / W reozA CL 0 W /71tW.4 1--- um, O Li man 12844 MILITARY ROAD S TECTURE NAC NO FILE DRAWN CHECKED DATE 121 -10017 G0.1 KRL SRW 9 -10 -2010 ) 0 EXISTING STEEL COLUMN BELOW 4, -4" -11 0 EXISTING W14 SITEEL WIDE FLANGE HVAC UNIT ABQ & VE ROOF, LOCATE TO BEAR ON () STEEL JOISTS WIDE FLANGE B AM EXISTING 14" STEEL JOISTS ® 5'— 1' -0 "f BEAM CURB STEEL )" OC OUTLINE OF CT ROOM EXAM ROOM r L rJ 0 OF 4" TUBE STEEL SAWCUT OPENING IN . 5" THICK CONCRETE ROOF STRUCTURE 4" TUBE STEEL ROOF SLAB SUPPORT EXISTING CONCRETE WALL APPROXIMATE POSITION OF CT GANTRY BELOW, SEE A3.1 EXISTING CONCRETE ROOF BEAM PARTIAL REFLECTED ROOF STRUCTURE PLAN Scale: 1/4" = 1' -0" #14 x 21/2" LG WOOD SCREWS ® 12" @ PERIMETER OF CURB r LJ UNIT CURB vo mu ow ow owl ♦ . • 1 TREATED WOOD NAILERS W/ (2) #12 SELF — DRILLING SHEET METAL SCREWS ® 12" OC, 4 SIDES OF CURB TOP & BOTTOM, NEAR SIDE & FAR SIDE A GENERAL STRUCTURAL NOTES QUALITY ASSURANCE: " • -- -- -- I C I�EVItVVtL) ODE COMPLIANCE taraMnificn DEC 1 u 2U1U City of Tukwila BUILDING DIVISION 1. SPECIAL INSPECTIONS ARE REQUIRED IN ACCORDANCE WITH CHAPTER 17 OF THE IBC FOR THE FOLLOWING WORK: CONCRETE INSTALLING EXPANSION BOLTS INSTALLING EPDXY BOLTS & DOWELS (PERIODIC) (CONTINUOUS) WELDING (CONTINUOUS, UON) WELDING - SINGLE -PASS, %6 FILLET OR LESS (PERIODIC) ANCHORAGE: 2. EXPANSION BOLTS INTO CONCRETE SHALL BE AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY, INC. OR HILTI INC. INSTALLED IN STRICT ACCORDANCE WITH APPLICABLE ICC -ES REPORTS, INCLUDING MINIMUM TORQUE REQUIREMENTS. EMBEDMENT DEPTHS SHALL BE AS INDICATED. SPECIAL INSPECTION IS REQUIRED FOR INSTALLATION OF ALL EXPANSION BOLT AND INSERT INSTALLATION. MANUFACTURER SIMPSON STRONG -TIE COMPANY, INC. HILTI, INC. MATERIAL PRODUCT ICC -ES REPORT CONCRETE STRONG BOLT ESR -1771 CONCRETE KWIK BOLT TZ (KB -TZ) ESR -1917 3. EPDXY- GROUTED ANCHORS REINFORCING BAR INTO CONCRETE SHALL BE GROUTED WITH EPDXY ADHESIVE BY SIMPSON STRONG -TIE COMPANY, INC. OR HILTI INC. INSTALLED IN STRICT ACCORDANCE WITH APPLICABLE ICC -ES REPORTS. SPECIAL INSPECTION IS REQUIRED FOR ALL EPDXY- GROUTED ANCHOR INSTALLATIONS. MANUFACTURER SIMPSON STRONG -TIE COMPANY, INC. HILTI, INC. MATERIAL CONCRETE CONCRETE PRODUCT SET XP EPDXY HIT -RE 500 -SD ICC -ES REPORT ESR -2508 ESR -2322 EXISTING 14" STEEL JOIST ADD L 11 x 11 x 44e ® PANEL POINT, NEAR SIDE & FAR SIDE, TYPICAL OF 2 JOISTS HVAC CURB SUPPORT SCALE: 1 -1 /2 " =1' -0" EXISTING CONCRETE ROOF SLAB HSS 4X 4X V4, NO FASTENERS TO SLAB (1) % "m THREADED STUD, NUT & WASHER. USE SLOTTED HOLE IN ANGLE FOR TOLERANCE L 4x 4x Y4x O' -7" W/ (2) % "4 EXPANSION BOLTS ® 41" CENTER TO CENTER EXISTING 14 "W x 20 "D CONCRETE BEAM ®ROOF OPENING SUPPORT DETAIL SCALE: 1 -1 /2 " =1' -0" RF006 (2) #4 CONT. — EMBED 4" INTO EXISTING CONCRETE BEYOND CONCRETE INFILL EXISTING OPENING EXISTING CONCRETE FLOOR STRUCTURE #4 x (SLAB OPENING MINUS 1 ") DOWELS, EPDXY GROUT 0 8" OC MAXIMUM EACH SIDE, CENTER IN CONCRETE SLAB CONCRETE FLOOR INFILL SCALE: 1 -1 /2 " =1' -0" RECEIVED CITY OF TUKIMLA NOV 2 4 2010 PERMIT CENTER IFO11 CORRECTION LTqlf ._- PARTIAL ROOF STRUCTURE PLAN 0 STRUCTURAL DETAILS o REVISIONS A 11/02/2010 aTY OF TUKWILA COMMENT RESPONSE 2 0 0 z w w 0 0 w 1— z w 2 0 U w monl 0 w V) 0 stt 1— _71 2 00 TECTURE NAC NO FILE DRAWN CHECKED DATE 121 -10017 A5 -1 SRW SRW 9 -10 -2010 i� • .. • I0] I W.. O 0 Ip —10 oa Er- c RADIOLOGY ROOM I PAT TLT II0 TECH SUPPORT s, HALLWAY RADI • LOGY ROOM 121 CONTROL ROOM MI MI IN III NI NI OM NO NI NIL IIII m — s rrn PATIENT DRESSING II■ ■II CORRIDOR 1 AREA OF WORK _, ■ 1 mu Ma 111 UM MN Ilii MN m MN II UN UN WM ■ a/ Ow in in im In irm lira ME 0 ` ii ................ no 1,.. 0 STORAGE CORRIDOR 1 1 1 OFFICE DIAGNOSTIC IMAGING RECEPTION 1 arm HALLWAY CT EXAM ROOM U NMI ®L] �� CONTRO ROOM CORRIDOR ..0 ..I IN NO a -- FITWTTMITWIll v WEST WING FIRST FLOOR LIFE /SAFETY PLAN ■I1 r>' ■II 'V/ '1 'f Scale: 1 /8" = 1' -0" 0 2 4 8 ,J 16 CODE DATA CONSTRUCTION TYPE: OCCUPANCY TYPE: ALLOWABLE AREA: FIRE PROTECTION: GOVERNING CODES: NUMBER OF STORIES: FLOOR AREA: WEST WING — TYPE II —A (NO CHANGE) GROUP 1 -2: HOSPITAL (NO CHANGE) 90,000 SF FULLY SPRINKLERED PER 903.3.1.1 AND NFPA 13 (NO CHANGE) FIRE ALARM SYSTEM (NO CHANGE) WASHINGTON STATE BUILDING CODE 2009 INTERNATIONAL BUILDING CODE (WAC AMENDMENTS) 2003 ICC /ANSI A117.1 (WAC AMENDMENTS) 2009 INTERNATIONAL MECHANICAL CODE (WAC AMENDMENTS) 2009 INTERNATIONAL FIRE CODE (WAC AMENDMENTS) 2009 UNIFORM PLUMBING CODE (WAC AMENDMENTS) 2008 NATIONAL ELECTRICAL CODE (WAC AMENDMENTS) WASHINGTON STATE NON— RESIDENTIAL ENERGY CODE CITY OF TUKWILA BUILDING AND ZONING CODES 3 (NO CHANGE) AREA OF TENANT IMPROVEMENT = 509 S.F. CODE PLAN GENERAL NOTES 1. SEE FLOOR PLANS FOR DIMENSIONS, WALL TYPE REFERENCES. 2. SEE ELECTRICAL FOR EXIT SIGNS AND EMERGENCY EGRESS LIGHT FIXTURES. 3. WEST WING IS TYPE II —A, FULLY SPRINKLED CONSTRUCTION. QUICK RESPONSE HEADS ARE USED WHERE ALLOWED BY IBC CHAPTER 9. 6. FIRESTOP ALL PENETRATIONS THROUGH FIRE —RATED WALL AND FLOOR /CEILING ASSEMBUES. SEAL PENETRATIONS TO RETAIN THE INTEGRITY OF THE TIME —RATED CONSTRUCTION 7. INTERIOR WALL AND CEILING FINISHES SHALL CONFORM TO IBC SECTION 803.1 AND TABLE 803.4 FOR FLAME SPREAD REQUIREMENTS. FIRE PROTECTION NOTES 1. SEE MECHANICAL DRAWINGS FOR FIRE SPRINKLER SYSTEM ALTERATIONS ASSOCIATED WITH TENANT IMPROVEMENT WORK IN ACCORDANCE WITH IBC 903.1 AND NFPA 13, SPRINKLER DRAWINGS TO BE SUBMITTED BY LICENSED INSTALLER. 2. SEE ELECTRICAL DRAWINGS FOR BUILDING FIRE ALARM SYSTEM ALTERATIONS ASSOCIATED WITH TENANT IMPROVEMENT WORK PER NFPA 72, FIRE ALARM DRAWINGS TO BE SUBMITTED BY LICENSED INSTALLER. 3. FIRE EXTINGUISHERS TO BE PROVIDED ON A MAXIMUM TRAVEL DISTANCE OF 75' TO ANY EXTINGUISHER LOCATION. PLAN LEGEND - - - - - - - EXISTING FIRE PARTITION, 1 HOUR FIRE— RESISTIVE RATING PER IBC 708 1111111111111111111111 EXISTING SMOKE BARRIER, 1 HOUR FIRE — RESISTIVE RATING PER INC 709 NEW FIRE BARRIER, 1 HOUR FIRE— RESIS11VE RATING PER IBC 708 1 I 1.11 U 11 U i l 1 EXISTING FIRE BARRIER, 2 HOUR FIRE — RESISTIVE RATING PER IBC 706 I OCCUPANCY I OCCUPANCY SUITE (THIS PROJECT) FIRESTOPPING: ALL PENETRATIONS MADE THROUGH FIRE —RATED WALLS, CEILINGS AND FLOOR ASSEMBLIES, BOTH EMPTY HOLES AND HOLES ACCOMMODATING SUCH ITEMS AS DUCTS, PIPES, CONDUIT, ETC. SHALL BE SEALED. PENETRATIONS SHALL BE SEALED TO RETAIN THE INTEGRITY OF THE TIME —RATED CONSTRUCTION BY MAINTAINING AN EFFECTIVE BARRIER AGAINST THE SPREAD OF FLAME, SMOKE, AND GASES, IN ACCORDANCE WITH THE REQUIREMENTS OF IBC SECTION 712 — FIRESTOPPING. MECHANICAL AND ELECTRICAL RELATED PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR MAKING THE PENETRATION — SEE MECHANICAL AND ELECTRICAL. REVIEWED FOR CODE COMPLIANCE DEC 10 20•it City of Tukwila BUILDING DIVIRIflM RECEIVED OCT 13 2010 PERMIT CENTER (131 KEY PLAN NOT TO SCALE PARTIAL FIRST FLOOR LIFE /SAFETY PLAN zz 00 0 N REVISIONS 5785 ' :GIST 'ED a RC /� 'CT i •AiIE ,R•INE STATE • L.HINGTON (0 N". 0 0 z w 2 w U a. w tt 1- z w 2 0 z o 0- z 2 Q Q 5 U Finn 1 IVLA 't r* r s404 w remm F— Pip votl TECTURE c.; NACNO 121 -10017 FILE G1 -1 DRAWN SRW CHECKED SRW DATE 9 -10 -2010 G 1.1 2201 SIXTH AVENUE I SUITE 1405 I SEATTLE WA 98121 -1847 I P: 206.441.4522 I F206.442.7917 2 0 0 w W U 0 a 1 rn z 0 rx I ai °a w fn M go co o CO O 0 O O � DO Z a wa — 0 Z wQ ¢w 0 M O J � L GENERAL C: AHU -01 0 Mar /AA1 O EXISTING MECHANICAL TO BE REMOVED EXISTING MECHANICAL TO REMAIN NEW MECHANICAL WORK MATCHLINE OR PROPERTY LINE ENLARGED PLAN BOUNDARY DETAIL /PLAN IDENTIFIER SECTION IDENTIFIER ELEVATION IDENTIFIER REVISION DEFINITION AREA, AREA ENCIRCLED CONTAINS CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE REVISION CALLOUT FLAG NOTE CALLOUT DEMOLITION NOTE TAG EQUIPMENT TAG MECHANICAL EQUIPMENT TAG MECHANICAL EQUIPMENT TAG NORTH ARROW LOCATION WHERE PICTURE WAS TAKEN AND DIRECTION INVERT ELEVATION OR POC ELECTRICAL PROVISIONS FOR MECHANICAL WORK Di VFD HT LOCATION OF STARTER, DISCONNECT & CONTROLS VARIABLE FREQUENCY DRIVE HEAT TRACE BETWEEN SYMBOLS OR END OF RUN ACCESS, EXCAVATION, AND BACKFIWNG PIPING ACCESS DOOR (SPECIFIED OR AS SHOWN ON DWGS) MECHANICAL ACCESS (SPECIFIED OR AS SHOWN ON DWGS) 0 -0 4 1 PIPE ELBOW UP OR PIPE TEE UP AND DOWN PIPE ELBOW DOWN PIPE TEE UP PIPE TEE DOWN PIPE RISE PIPE CAP PIPE PLUG FLOW DIRECTION PIPE BREAK PIPE CONNECTION VALVES Dg PIPING SPECIALTIES VALVE: GATE, BALL, BUTTERFLY (REFER TO SPECIFICATIONS) GLOBE VALVE SOLENOID VALVE CHECK VALVE BALANCING VALVE PRESSURE REDUCING VALVE REDUCED PRESSURE BACKFLOW ASSEMBLY SAFETY RELIEF VALVE TEMPERATURE /PRESSURE RELIEF VALVE 1,4 11 1 T/P 9 UNION FLANGE FLEX CONNECTOR THERMAL /SEISMIC FLEXIBLE LOOP EXPANSION JOINT STRAINER STRAINER WITH BLOW OFF VALVE PIPE ANCHOR ALIGNMENT GUIDE TEMPERATURE /PRESSURE TEST PORT THERMOMETER PRESSURE GAGE SOIL AND WASTE WATER PIPING SYSTEM X" VTR -o 0 0 O II Co IlwCo 0 FCO SANITARY SEWER /WASTE UNDERGROUND SANITARY SEWER /WASTE ABOVE GROUND VENT PIPING VENT THRU ROOF (INCLUDE SIZE) FLOOR DRAIN /FUNNEL FLOOR DRAIN FLOOR SINK HUB DRAIN TRENCH DRAIN CLEANOUT CLEANOUT - FREE STANDING WALL MOUNTED CLEANOUT - FLUSH WITH FLOOR DOMESTIC WATER PIPING SYSTEM I b I DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER CIRCULATION HOSE BIBB /WALL HYDRANT TRAP PRIMER BOX FIRE PROTECTION SYSTEM F FIRE SPRINKLER RECESSED SPRINKLER HEAD SEMI - RECESSED SPRINKLER HEAD UPRIGHT SPRINKLER HEAD NATURAL GAS PIPING SYSTEM 0 LOW PRESSURE NATURAL GAS PIPING GAS COCK PRESSURE REGULATOR PRESSURE REGULATOR WITH VENT SEISMIC GAS SHUT -OFF GAS PRESSURE REDUCING VALVE WITH VENT MEDICAL GAS PIPING SYSTEM MV 02 NO ■ INLETS AND OUTLETS MEDICAL AIR MEDICAL VACUUM OXYGEN NITROUS OXIDE MEDICAL GAS ZONE VALVE BOX MEDICAL GAS AREA ALARM PANEL MEDICAL GAS MASTER ALARM PANEL MEDICAL GAS OUTLET TYPE A - MEDICAL AIR ✓ - MEDICAL VACUUM O - OXYGEN N - NITROUS OXIDE S - VACUUM SLIDE MEDICAL GAS OUTLET QTY. (IF QTY. NOT INDICATED ASSUME 1 OUTLET) LOCKED CLOSED VALVE LOCKED OPEN VALVE 24x24 500 4. 1-- --JL -- GRILLE REGISTER OR DIFFUSER TYPE RUNOUT SIZE (INCHES) AIR QUANTITY (CFM) CEILING DIFFUSER 1 -WAY DIRECTION FLOW 2 -WAY DIRECTION FLOW 3 -WAY DIRECTION FLOW RETURN /RELIEF AIR GRILLE EXHAUST AIR GRILLE LINEAR DIFFUSER /GRILLE SUPPLY GRILLE RETURN /EXHAUST GRILLE TRANSFER GRILLE RETURN /EXHAUST AIRFLOW SUPPLY AIR FLOW DUCTWORK BDD 11 1 1 1 11 ■ € 20x10 1 C1 ilit1tll —:_:NM ■III■N • c=i1=m c=41:3 E=4 043 A-1 1/1 FACE DAMPERS BACKDRAFT DAMPER VOLUME DAMPER FLEXIBLE CONNECTION TO MECHANICAL EQUIPMENT TRANSITION - RECTANGULAR TO ROUND DUCT SIZE (CLEAR INSIDE DIMENSION) SOUNDLINED DUCTWORK RECTANGULAR DUCT UP RECTANGULAR DUCT DN ROUND OR OVAL DUCT UP ROUND OR OVAL DUCT DN FLEXIBLE DUCTWORK DUCT RISE /DROP WITH 90' ELBOWS (RECTANGULAR DUCTS) DUCT RISE /DROP WITH 45' ELBOWS (RECTANGULAR DUCTS) DUCT RISE /DROP WITH 90' ELBOWS (ROUND OR OVAL DUCT) DUCT RISE /DROP WITH 45' ELBOWS (ROUND OR OVAL DUCTS) TRANSITION OR REDUCER TRANSITION - ECCENTRIC 45' ELBOW, R/D OR R /W =1.5 90' ELBOW, R/D OR R /W =1.5 SQUARE CORNER ELBOW WITH TURNING VANES 90' CONICAL TAKE -OFF 90' TAKE -OFF WITH 45' TAPER 45' TAKE -OFF RADIUS TAP IN WYE FITTING RADIUS TEE SQUARE TEE WITH TURNING VANES BULLHEAD TEE SECTION THRU SUPPLY AIR DUCT SECTION THRU RETURN, EXHAUST OR OUTSIDE AIR DUCT SECTION THRU ROUND DUCT SUPPLY ROOF PENETRATION RETURN, EXHAUST OR OUTSIDE AIR ROOF PENETRATION ROUND DUCT ROOF PENETRATION FIRE DAMPER FIRE /SMOKE DAMPER SMOKE DAMPER CEILING FIRE DAMPER CONTROLS (PLAN VIEW) T THERMOSTAT OR X TEMPERATURE SENSOR t1 DDC tx DRAWING INDEX SENSOR: SHOWN WITH GUARD (TYPICAL ALL SENSORS) HUMIDISTAT OR HUMIDITY SENSOR CARBON MONOXIDE SENSOR CARBON DIOXIDE SENSOR INDOOR AIR QUALITY SENSOR MOTORIZED DAMPER AIRFLOW MEASURING UNIT DUCT SMOKE DETECTOR TEMPERATURE TRANSMITTER PRESSURE TRANSMITTER AQUASTAT DIFFERENTIAL PRESSURE SENSOR DIFFERENTIAL PRESSURE MONITOR AUTOMATIC CONTROL VALVE, 3 -WAY AUTOMATIC CONTROL VALVE, 2 -WAY DIRECT DIGITAL CONTROL PANEL SWITCH BY MECHANICAL MO.1 MECHANICAL LEGEND MO.2 GENERAL NOTES AND ABBREVIATIONS MO.3 MECHANICAL SPECIFICATIONS MO.4 MECHANICAL SPECIFICATIONS MO.5 MECHANICAL SPECIFICATIONS MO.6 MECHANICAL SPECIFICATIONS MO.7 MECHANICAL EQUIPMENT SCHEDULES M1.1 BASEMENT PLUMBING DEMOLITION PLAN M1.2 FIRST FLOOR PLUMBING DEMOLITION PLAN M1.3 FIRST FLOOR HVAC DEMOLITION PLAN M2.0 BASEMENT PLUMBING PLAN M2.1 FIRST FLOOR PLUMBING PLAN M3.1 FIRST FLOOR HVAC PLAN M5.1 FIRST FLOOR FIRE SUPPRESSION PLAN M6.1 MECHANICAL ROOF PLAN M9.1 MECHANICAL DETAILS REVIEWED FOR CODE COMPLIANCE APPRPMED DEC 10 2tral City of Tukwila BUILDING DIVI,SInhi RECEIVED OCT 13 2010 PERMIT CENTER NOT ALL SYMBOLS MAY APPEAR ON THE DRAWINGS REVISIONS MECHANICAL LEGEND N Q_ TECTURE u NAC NO 121 -10017 HEINO 10113 DRAWN JMR CHECKED RKE DATE 9 -10 -2010 8.30.2010 ABBREVIATIONS 0 A MV ABV AC ACU AD ADA AF AFF AFS AFUE AG AHJ AHU AL AMB AP APD ARCH ASHRAE ASSY ATM AV AW B BC BDD BF BHP BLW BOD BOP BOT BTUH BV C CA CAP CBV CC CD CFG CFM CG CH CHR CHS CHP CKV CLG CO CO2 COMB COND CONN CONT COP COTG CR CS CT CTF C. TK CU Cv CV CW CWR CWS D DB dB DCVA DDCV DEG DFU DH DI DIA DIM DISC DISCH DN DPV DWGS DV DWB (E) EA EAT EER EF EFF EG EJ EL ELEC EMCS EQUIV ESP ET EVAP EWC EWT EXH EXT DIAMETER, PHASE AIR, AMPS AUTOMATIC AIR VENT ABOVE AIR CONDITIONER AIR CONDITIONING UNIT ACCESS DOOR AMERICANS WITH DISABIUTIES ACT AIRFOIL ABOVE FINISHED FLOOR AIRFLOW MEASURING STATION ANNUAL FUEL UTILIZATION EFFICIENCY ABOVE GROUND AUTHORITY HAVING JURISDICTION AIR HANDLING UNIT ACOUSTIC LINED (DUCT) AMBIENT ACCESS PANEL AIR PRESSURE DROP ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR - CONDITIONING ENGINEERS, INC. ASSEMBLY ATMOSPHERE ACID RESISTANT VENT ACID RESISTANT WASTE BOILER BOILER COIL BACK DRAFT DAMPER BELOW FLOOR BRAKE HORSE POWER BELOW BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BRITISH THERMAL UNIT PER HOUR BALL VALVE CONDENSATE PIPING AIR COMPRESSOR CAPACITY CIRCUIT SETTING BALANCING VALVE COOUNG COIL CEILING DIFFUSER, CONDENSATE DRAIN CEILING FIRE DAMPER CUBIC FEET PER MINUTE CEILING GRILLE CABINET HEATER, CHILLER CHILLED WATER RETURN, CHILLER CHILLED WATER SUPPLY CHILLED WATER PUMP CHECK VALVE CEILING, COOLING CLEANOUT, CO SENSOR CO2 SENSOR COMBUSTION, COMBINATION CONDENSER, CONDENSATE CONNECTOR CONTINUE, CONTROL COEFFICIENT OF PERFORMANCE CLEANOUT TO GRADE CONDENSATE RECEIVER, CONDENSER WATER RETURN CONDENSER WATER SUPPLY COOLING TOWER COOUNG TOWER FILTER COMPRESSION TANK CONDENSING UNIT, CUBIC FLOW COEFFICIENT CONSTANT VOLUME COLD WATER PIPING CONDENSING WATER RETURN CONDENSING WATER SUPPLY DRAIN DRY BULB (TEMPERATURE) DECIBEL DOUBLE CHECK VALVE ASSEMBLY DOUBLE DETECTOR CHECK VALVE DEGREE DRAINAGE FIXTURE UNIT DUCT HEATER DUCTILE IRON DIAMETER DIMENSION LOCATION OF STARTER, DISCONNECT AND CONTROLS DISCHARGE DOWN DIFFERENTIAL PRESSURE VALVE DRAWINGS DRAIN VALVE DOMESTIC WATER BOOSTER EXISTING EXHAUST AIR ENTERING AIR TEMPERATURE ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY EXHAUST GRILLE, ENGINE GENERATOR EXPANSION JOINT ELEVATION ELECTRIC ENERGY MANAGEMENT AND CONTROL SYSTEM EQUIVALENT EXTERNAL STATIC PRESSURE EXPANSION TANK EVAPORATOR, EVAPORATIVE ELECTRIC WATER COOLER ENTERING WATER TEMP EXHAUST EXTERIOR, EXTERNAL F FC FCO FCU FD FDC FF FFD FLA FLEX FLR FLTR FMS FOR FOS FOT FP FPM FPS FPVC FS F/S FT FTD FTG FTU FV FW G GA GAL GALV GAHU GC GFU GPF GPH GPM GPRV GRD GV GW GWB H HB HC HD HGL HORIZ HP HPC HPS HRU HST HTG HVAC HW HWC HWR HWS HX HZ IAQ ID IE IN. IN. WG IRR IW kW L LAT LB LBS LL LPC LPG LPS LRA LR LVR LWR LWS LWCD LWT MA MAC MAT MAV MAX MBH MC MCA MECH MERV MIN MOCP MOD MPC MPG MPS MV FAHRENHEIT, FIRE MAIN PIPING FLUID COOLER FLOOR CLEANOUT FAN COIL UNIT FIRE DAMPER, FLOOR DRAIN, DRY SPRINKLER ROUTING FIRE DEPARTMENT CONNECTION FOUUNG FACTOR, FLAT FILTER FUNNEL FLOOR DRAIN FULL LOAD AMPS FLEXIBLE FLOOR FILTER FLOW MEASUREMENT STATION (HVAC, PLUMBING) FUEL OIL RETURN PIPING FUEL OIL SUPPLY PIPING FUEL OIL TANK FIRE PUMP, FLOATING POINT CONTROL FEET PER MINUTE FEET PER SECOND APPROVED PVC FIRE SPRINKLER ROUTING FLOOR SINK FIRE /SMOKE DAMPER FEET, FIN TUBE FOOTING DRAIN FOOTING DRAIN FIN TUBE UNIT FACE VELOCITY FILTERED WATER PIPING GAS GAGE GALLONS GALVANIZED GAS AIR HANDLING UNIT GAS COCK, GENERAL CONTRACTOR GAS FIRED UNIT GALLONS PER FLUSH GALLONS PER HOUR GALLONS PER MINUTE GAS PRESSURE REGULATING VALVE GRILLES, REGISTERS, AND DIFFUSERS GATE VALVE, GLOBE VALVE GREASE WASTE PIPING GYPSUM WALLBOARD HUMIDISTAT, HEIGHT HOSE BIBB HEATING COIL HEAD, HUB DRAIN REFRIGERANT HOT GAS LINE HORIZONTAL HORSEPOWER, HEAT PUMP HIGH PRESSURE CONDENSATE RETURN HIGH PRESSURE STEAM HEAT RECOVERY UNIT STORAGE TANK HEATING HEATING, VENTILATING, AND AIR CONDITIONING HOT WATER PIPING HOT WATER CIRCULATING PIPING HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HERTZ INDOOR AIR QUALITY INDIRECT DRAIN INVERT ELEVATION INCH INCHES WATER COLUMN IRRIGATION PIPING INDIRECT WASTE PIPING KILOWATT LENGTH LEAVING AIR TEMPERATURE LINEAR BAR POUND LINEAR DIFFUSER REFRIGERANT LIQUID UNE LOW PRESSURE CONDENSATE RETURN LIQUID PETROLEUM GAS PIPING LOW PRESSURE STEAM LOCKED ROTOR AMPS LINEAR RETURN LOUVER LOW WALL RETURN LOW WALL SUPPLY LOW WATER CUT -OFF LEAVING WATER TEMPERATURE MEDICAL AIR MEDICAL AIR COMPRESSOR MIXED AIR TEMPERATURE MANUAL AIR VENT MAXIMUM THOUSAND BTU PER HOUR MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MECHANICAL MINIMUM EFFICIENCY REPORTING VALUE MINIMUM MAXIMUM OVERCURRENT PROTECTION MOTOR OPERATED DAMPER MEDIUM PRESSURE CONDENSATE RETURN MEDIUM PRESSURE GAS MEDIUM PRESSURE STEAM MEDICAL VACUUM NA NC NIC NO NO. NP NTS 02 OA OBD OC OD ORD ORL OSA OSD OV P PD PH PIV POC PR PRV PSIG QTY RA RD REG REF RF RG RH RI &C RL RLA RO RPBA RPBP RPM RTU RV S SA SAT SCFM SCH SD SENS SF SG SIM SL SMACNA SO SOV SP SPKR SPS SS ST STM SW S. TK T TBV TCV TD TEMP TG TOD TOP TOS TOF TSP T'STAT TU TYP UG UH UNO V VA VAV VCD VD VEL VENT VFD VOLT VTR W WB WC WCO WG WH WHA WM WSEC WSFU WT NOT APPUCABLE NORMALLY CLOSED, NOISE CRITERIA NOT IN CONTRACT NORMALLY OPEN, NITROUS OXIDE NUMBER NON POTABLE NOT TO SCALE OXYGEN OUTDOOR AIR OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIMENSION OR DIAMETER OVERFLOW ROOF DRAIN OVERFLOW RAIN LEADER OUTDOOR SUPPLY AIR OVER -FLOW STORM DRAIN OUTLET VELOCITY PUMP, PRESSURE, PLUMBING FIXTURE PRESSURE DROP, PUMPED DRAIN PHASE POST INDICATOR VALVE POINT OF CONNECTION CONDENSATE PUMP RETURN PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH GAGE QUANTITY RETURN AIR, RELIEF AIR ROOF DRAIN REGISTER REFERENCE, RETURN /EXHAUST FAN REUEF FAN RETURN GRILLE ROOF HOOD ROUGH IN AND CONNECT RAIN LEADER RATED LOAD AMPS REVERSE OSMOSIS REDUCED PRESSURE BACKFLOW ASSEMBLY REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE ROOFTOP UNIT SAFETY RELIEF VALVE SENSOR SUPPLY AIR SUPPLY AIR TEMPERATURE STANDARD CUBIC FEET PER MINUTE SCHEDULE STORM DRAIN PIPING SENSIBLE SUPPLY FAN, SQUARE FOOT SUPPLY GRILLE, SIGHT GLASS WITH MOISTURE INDICATOR SIMILAR REFRIGERANT SUCTION LINE SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, INC. SCREENED OPENING SHUTOFF VALVE STATIC PRESSURE SPRINKLER STATIC PRESSURE STATION STAINLESS STEEL, SANITARY SEWER SOUND TRAP STEAM SOFT WATER PIPING STORAGE TANK TEMPERED WATER PIPING TOWER BYPASS VALVE TEMPERATURE CONTROL VALVE TRENCH DRAIN, TEMPERATURE DIFFERENCE TEMPERATURE TRANSFER GRILLE TOP OF DUCT TOP OF PIPE TOP OF STEEL TOP OF FOOTING TOTAL STATIC PRESSURE THERMOSTAT TERMINAL UNIT TYPICAL UNDERGROUND UNIT HEATER UNLESS NOTED OTHERWISE VENT PIPING, VOLT VALVE VARIABLE AIR VOLUME VOLUME CONTROL DEVICE VOLUME DAMPER VELOCITY VENTILATION, VENTILATOR VARIABLE FREQUENCY DRIVE VOLTAGE VENT THRU ROOF WASTE, WATT, WIDE, WATER WET BULB (TEMPERATURE) WATER CLOSET, WATER COLUMN WALL CLEANOUT WATER GAGE WATER HEATER, WALL HYDRANT WATER HAMMER ARRESTOR WATER METER WASHINGTON STATE ENERGY CODE WATER SUPPLY FIXTURE UNIT WEIGHT GENERAL NOTES - MECHANICAL 1. COORDINATE MECHANICAL WORK WITH THAT OF OTHER TRADES (ELECTRICAL, ARCHITECTURAL, STRUCTURAL) REFER TO ELECTRICAL, ARCHITECTURAL AND STRUCTURAL DRAWINGS AND SPECIFICATIONS. COORDINATION SHALL OCCUR PRIOR TO FABRICATION, PURCHASE, AND /OR INSTALLATION OF ALL WORK. 2. COORDINATE PLUMBING, HVAC, AND FIRE PROTECTION SYSTEMS ROUTING PRIOR TO INSTALLATION. DURING LAYOUT COORDINATION, DUCTWORK TAKES PRECEDENCE OVER PLUMBING, INCLUDING FIRE PROTECTION SYSTEMS. 3. UNLESS OTHERWISE SPECIFIED, THE GENERAL CONTRACTOR (GC) SHALL BE RESPONSIBLE FOR PAINTING, CUTTING, AND PATCHING OF EXISTING FLOORS, WALLS, AND PARTITIONS IN THE EXISTING BUILDING. 4. REFER TO STRUCTURAL DRAWINGS FOR ALLOWABLE METHODS /LOADS FOR HANGING PIPING /DUCTS FROM STRUCTURAL MEMBERS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFE KEEPING OF HIS OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION OF PROPERTIES AGAINST FIRE, THEFT, AND ENVIRONMENTAL CONDITIONS. MECHANICAL EQUIPMENT INSTALLATION NOTES 1. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. PIPING NOTES 1. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. 2. PRESSURE/TEMPERATURE TEST PORTS: PROVIDE AT SUPPLY AND RETURN PIPING CONNECTIONS TO EQUIPMENT. 3. PROVIDE AN INSULATED COPPER TRACER WIRE OR OTHER APPROVED CONDUCTOR ADJACENT TO UNDERGROUND NONMETALLIC (PLASTIC) PIPING. ACCESS SHALL BE PROVIDED TO THE TRACER WIRE OR THE TRACER WIRE SHALL TERMINATE ABOVE GROUND AT EACH END OF THE PIPING. THE TRACER WIRE SHALL NOT BE LESS THAN NO. 18 AWG AND THE INSULATION TYPE SHALL BE SUITABLE FOR BURIAL. 4. PROVIDE 12" LONG, 1/2" WIDE FLUORESCENT ORANGE TAPE AT CONCEALED VALVE LOCATIONS. PLUMBING NOTES 1. WATER HAMMER ARRESTERS: PROVIDE AT THE END OF HOT AND COLD WATER LINES SERVING TWO OR MORE FIXTURES. SIZE IN ACCORDANCE WITH PLUMBING AND DRAINAGE INSTITUTE (PDI) REQUIREMENTS. 2. CLEANOUTS: PROVIDE AT THE BASE OF SANITARY DRAINAGE, PROCESS WASTE, AND RAINLEADER CONDUCTORS. SHEET METAL NOTES 1. VOLUME DAMPERS: PROVIDE A MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING, LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE OPENING. PROVIDE A MANUAL VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE OPENING. 2. UNLESS NOTED TO USE LARGER SIZE DUCT, PROVIDE THE FOLLOWING MINIMUM SIZE BRANCH DUCTS TO CEILING DIFFUSERS. 6" DIA. FOR UP TO 120 CFM 8" DIA. FOR 121 -210 CFM 10" DIA. FOR 211 -300 CFM 12" DIA. FOR 301 -450 CFM 14" DIA. FOR 451 -600 CFM 16" DIA. FOR 601 -820 CFM 3. PROVIDE 12" LONG, A" WIDE FLUORESCENT ORANGE TAPE AT CONCEALED VOLUME DAMPER LOCATIONS. ENERGY CODE NOTES 1. MOTORS: COMPLY WITH MINIMUM FULL LOAD EFFICIENCIES LISTED IN ENERGY CODE ENFORCED BY AHJ. 2. PIPING AND DUCT INSULATION: COMPLY WITH THICKNESSES AND TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED. 3. DUCT SEALING: SEAL DUCT TRANSVERSE JOINTS AND LONGITUDINAL SEAMS PER ENERGY CODE ENFORCED BY AHJ UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED. 4. RECORD DRAWINGS: SUBMIT TO THE BUILDING OWNER PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. 5. OPERATION AND MAINTENANCE MANUALS: SUBMIT TO THE BUILDING OWNER PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. 6. SYSTEM BALANCING: BALANCE HVAC SYSTEMS PER ENERGY CODE ENFORCED BY THE LOCAL AHJ AND SUBMIT A WRITTEN REPORT TO THE BUILDING OWNER. REFER TO SPECIFICATIONS FOR ADDITIONAL TESTING, ADJUSTING, AND BALANCING (TAB) REQUIREMENTS. 7. MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS: TEST SYSTEMS TO ENSURE THAT BUILDING SYSTEMS HAVE BEEN DESIGNED, INSTALLED, AND FUNCTION PROPERLY, EFFICIENTLY, AND CAN BE MAINTAINED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS IN ORDER TO SATISFY THE BUILDING OWNER'S DESIGN INTENT AND OPERATIONAL REQUIREMENTS PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. REFER TO SPECIFICATIONS FOR ADDITIONAL COMMISSIONING REQUIREMENTS 8. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN DESIGNED TO COMPLY WITH ENERGY CODE ENFORCED BY THE LOCAL AHJ. CONTRACTOR IS RESPONSIBLE FOR CORRECT INSTALLATION OF ENERGY CONSERVATION MEASURES. REVIEWED FOR CODE COMPLIANCE ACIPIOPMF DEC 1 u 1U iU City of Tukwila BUILDING DI11IRIln1' NON-STRUCTURAL MECHANICAL COMPONENT NOTES 1. THE COMPONENT IMPORTANCE FACTOR (Ip) FOR ALL NON- STRUCTURAL COMPONENTS SHALL BE: Ip = 1.5 . THE FOLLOWING THE 2009 INTE THE AMERICAN ITEMS ARE TAKEN DIRECTLY FROM NATIONAL BUILDING CODE AND FROM OCIETY OF CIVIL ENGINEERS (ASCE) 5. THE CONTRACTOR SHALL REFER TO THE ABOVE FOR ADDITIONAL INFORMATION, EXCEPTIONS, AND FURTHER DESCRIPTIONS. THE CONTRACTOR SHALL ADHERE TO REQUIREMENTS AND AS SUCH, SHALL BE INCLUDED WITHIN BID. ALSO ECIFICATION SECTION 200548. 3. MECHANICAL, 0 '0 E ARCHITECTURAL, ELECTRICAL, AND NON- STRUCTURAL THAT ARE PERMANENTLY ATTACHED TO AND THEIR SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED AND CONSTRUCTED TO RESIST THE EFFECTS OF E MOTIONS IN ACCORDANCE WITH ASCE DING CHAPTER 14 AND APPENDIX 11A. TOR SHALL BE RESPONSIBLE FOR THE N OF A SEISMIC - FORCE- RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, OR SEISMIC- RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS AND SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL INCLUDE THE FOLLOWING: A. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS; B. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL; C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE DISTRIBUTION OF THE REPORTS; D. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION. 4. DIVISION 20, 21, 22, 23 RESPONSIBILITIES: A. HANGERS AND SEISMIC BRACING FOR MECHANICAL SYSTEMS SHALL BE DESIGNED AND SPECIFIED BY DIVISION 20, 21, 22, 23. DIVISION 20, 21, 22, 23 SHALL REFER TO THE MECHANICAL DRAWINGS FOR LOCATIONS OF EQUIPMENT AND HUNG MECHANICAL SYSTEMS AS STRUCTURAL DRAWINGS DO NOT SHOW THE LOCATIONS OF MECHANICAL EQUIPMENT, DUCTWORK, PIPING, AND OTHER COMPONENTS. B. DIVISION 20, 21, 22, 23 SHALL COORDINATE THE SUPPORT SYSTEMS AND DESIGN LOADS FOR HUNG PIPING AND OTHER MECHANICAL SYSTEMS (INCLUDING COMBINED MULTIPLE PIPE RUNS) WITH THE GENERAL CONTRACTOR AND THE STEEL AND WOOD JOIST MANUFACTURERS IN ADDITION TO OTHER TRADES THAT MAY BE IMPACTED. RECEIVED CITY OF TUKWILA NOV 2 aT lulu PERMIT CENTER U U GENERAL NOTES AND ABBREVIATIONS o REVISIONS 11/1/2010, COT COMMENTS • TECTURE u NAC NO 121 -10017 HEI NO 10113 DRAWN JMR CHECKED RKE DATE 9 -10 -2010 rn v 0 z J D_ o Q i cr)V) o CL co O TY j *N o °° 0 of N • Q Cu n- o z w< Qw O M J J DIVISION 20 - COMMON REQUIREMENTS FOR FIRE SUPPRESSION, PLUMBING, AND HVAC THIS DIVISION APPLIES TO ALL DIVISION 20 21, 22 AND 23 SECTIONS. GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND DIVISION 01 APPLY TO WORK IN THESE SECTIONS. SECTION 200500 - GENERAL PROVISIONS PART 1 - GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: WORK INCLUDES MATERIALS, EQUIPMENT, LABOR, SUPERVISION, 0 L AND ITEMS NECESSARY FOR THE CONSTRUCTION, INSTALLATION, CONNECTION, TESTING AND OPERATION OF MECHANICAL WORK. 1.2 CODES AND STANDARDS A. PERFORM WORK IN ACCORDANCE WITH WASHTINGTON STATE REQUIREMENTS AND LOCAL AHJ. B. CONFORM TO APPLICABLE INDUSTRY STANDARDS. C. NOTIFY THE A/E OF DEVIATIONS IN CONTRACT DOCUMENTS TO APPLICABLE CODES AND ORDINANCES PRIOR TO INSTALLATION OF THE WORK. 1.3 SUBMITTALS A. PRODUCT DATA: 1. SUBMIT PRIOR TO FABRICATION OF ASSEMBLIES AND DELIVERY OF PURCHASED ITEMS. 2. CLEARLY MARK CATALOG PAGES, EQUIPMENT, MODEL NUMBER AND ACCESSORIES. 1.4 STANDARDS OF QUALITY A. EQUIPMENT SHALL BE MANUFACTURER'S REGULARLY CATALOGUED ITEMS AND SHALL BE SUPPLIED AS A COMPLETE UNIT IN ACCORDANCE WITH MANUFACTURER'S STANDARD SPECIFICATIONS AND ANY OPTIONAL ITEMS REQUIRED FOR PROPER INSTALLATION FOR EQUIPMENT UNLESS OTHERWISE NOTED. EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND BEST TRADE PRACTICES. B. PRODUCTS SHALL BE NEW UNLESS INDICATED OTHERWISE IN THE CONTRACT DOCUMENTS. 1.5 SUBSTITUTIONS A. WHERE "MANUFACTURER" PARAGRAPHS INCLUDE THE WORDS "OR APPROVED ", PRIOR APPROVAL OF THE PROPOSED SUBSTITUTION BY A/E IS REQUIRED. B. WHEN THE A/E APPROVES A SUBSTITUTION REQUEST, THE APPROVAL IS GIVEN WITH THE UNDERSTANDING THAT THE BIDDER: 1. HAS DETERMINED THAT IT MEETS OR EXCEEDS THE QUALITY LEVEL OF THE SPECIFIED PRODUCT WILL PROVIDE THE SAME WARRANTY AND WILL COORDINATE INSTALLATION AND MAKE CHANGES WITH NO ADDITIONAL COST TO OWNER. C. WHENEVER A PRODUCT IS DESCRIBED BY DETAIL, SPECIFICATION, TRADE NAME, MANUFACTURER'S NAME OR CATALOG REFERENCE, USE ONLY SUCH PRODUCT. 1.6 DRAWINGS AND SPECIFICATIONS A. GENERAL: THE MECHANICAL DRAWINGS ARE DIAGRAMMATIC. COMPLETE DETAILS OF BUILDING FEATURES WHICH AFFECT FIRE SUPPRESSION, PLUMBING AND HVAC INSTALLATIONS MAY NOT BE SHOWN. FOR ADDITIONAL DETAILS, REFER TO OTHER CONTRACT DOCUMENTS. REPORT ANY DISCREPANCIES TO THE A/E ALONG WITH SUGGESTED REVISIONS. 1.7 RECORD DRAWINGS A. PREPARE RECORD DRAWINGS. RECORD DRAWINGS SHALL BE NEW RED LINED PRINTS AND SHOW THE MEASURED LOCATIONS OF PORTIONS OF THE WORK AND CHANGES THE CONTRACTOR HAS MADE. B. RECORD DRAWINGS SHALL SHOW ADDENDUM ITEMS, CHANGE ORDERS, CLARIFICATIONS, SUPPLEMENTAL INSTRUCTIONS, AND DEVIATIONS FROM THE DRAWINGS. 1.8 COORDINATION A. COORDINATE DIVISIONS 20, 21 22, AND 23 WORK WITH OTHER TRADES. B. BE AWARE OF RESTRICTED SPACE FOR INSTALLATION OF FIRE SUPPRESSION, PLUMBING, AND HVAC SYSTEMS. INCLUDE OFFSETS AND PERFORM REROUTING AND COORDINATION TO FIT ELEMENTS IN AVAILABLE SPACE. INCLUDE PROVISIONS FOR SUCH REQUIREMENTS IN BID. C. EQUIPMENT, DUCTWORK AND PIPING SHOWN ARE BASED ON EXISTING DRAWINGS AS AVAILABLE AND ON LIMITED PROJECT SITE OBSERVATIONS TO THE EXTENT POSSIBLE UNDER CURRENT CONDITIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. D. COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY THAT ATTACHMENT POINTS ON EQUIPMENT AND STRUCTURE CAN ACCEPT SEISMIC, WEIGHT, AND OTHER LOADS IMPOSED. 1.9 WARRANTY A. WARRANTY PERIODS WITHIN DIVISIONS 20, 21 22, AND 23 SHALL NOT COMMENCE UNTIL SUBSTANTIAL COMPLETION. MINIMUM PERIOD SHALL BE ONE YEAR. CONTRACTOR SHALL EXTEND LONGER WARRANTIES SPECIFIED IN OTHER SECTIONS. 1.10 DEMONSTRATION A. FOLLOWING INSTALLATION OF FIRE SUPPRESSION, PLUMBING, AND HVAC WORK AND PRIOR TO FINAL ACCEPTANCE DEMONSTRATE THAT EQUIPMENT AND SYSTEMS OPERATE AS INDICATED IN THE CONTRACT DOCUMENTS AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. END OF SECTION SECTION 200505 - PROJECT CLOSEOUT AND SYSTEM START -UP PART 1 - GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: WORK INCLUDES MATERIAL AND LABOR REQUIRED TO PERFORM START -UP OF EQUIPMENT AND SYSTEMS INSTALLED IN PROJECT TO PERFORM CHECKOUT OF SYSTEMS AND TO VERIFY COMPLETENESS OF PROJECT REQUIREMENTS. PART 2 - PRODUCTS NOT USED. PART 3 - EXECUTION 3.1 PROJECT CLOSEOUT PROCEDURES A. COMPLETE WORK DESCRIBED IN THIS SECTION PRIOR TO TIME OF SUBSTANTIAL COMPLETION. B. MECHANICAL SUBCONTRACTOR SHALL BEAR PRIME RESPONSIBILITY FOR STARTUP OF HEATING AND COOLING AND PLUMBING SYSTEMS. C. INCLUDE DOCUMENTATION REQUIRED BY THE GOVERNING CODES. 3.2 SYSTEM START -UP PROCEDURES A. PROVIDE START UP BY AUTHORIZED FACTORY REPRESENTATIVE WHEN INDICATED. B. RECOMMENADJUSTMENTS IRATO CLEANING IU NTOSTARTC MECHANICAL ITEMS PER MANUFACTURER'S 3.3 FINAL ACCEPTANCE A. FINAL ACCEPTANCE OF WORK WILL NOT OCCUR UNTIL FUNCTIONAL TESTING IS COMPLETE AND OUTSTANDING ISSUES RESOLVED. END OF SECTION SECTION 200510 - BASIC MATERIALS AND METHODS PART 1 - GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: WORK INCLUDES EQUIPMENT SUPPORTS, SLEEVES IDENTIFICATION, APPURTENANCES AND MISCELLANEOUS WORK. THIS SECTION APPLIES TO ALL 1.2 QUALITY ASSUI�ANC'E 22, AND 23 SECTIONS. A. UL COMPLIANCE: WHERE UL FIRE - RESISTANCE RATING IS INDICATED FOR CONSTRUCTION PENETRATED BY ACCESS UNITS, FURNISH UL LISTED AND LABELED UNITS EXCEPT FOR THOSE UNITS WHICH ARE SMALLER THAN MINIMUM SIZE REQUIRING RATINGS AS RECOGNIZED BY GOVERNING AUTHORITY. B. ANSI COMPLIANCE: COMPLY WITH ANSI A13.1 FOR LETTERING SIZE, COLORS AND INSTALLED VIEWING ANGLES OF IDENTIFICATION DEVICES UNLESS OTHER REQUIREMENTS ARE SPECIFIED. 1.3 SUBMITTALS A. PRODUCT DATA: PIPE MARKERS ACCESS DOORS, VALVE TAGS. 1.4 PRODUCT DELIVERY, STORAGE, AND HANDLING A. DELIVER STORE, AND HANDLE PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, USING MEANS AND METHODS TO PREVENT DAMAGE, DETERIORATION, AND LOSS, INCLUDING THEFT. B. DELIVER PRODUCTS TO SITE IN MANUFACTURER'S ORIGINAL CONTAINERS, COMPLETE WITH LABELS. C. INSPECT PRODUCTS UPON DELIVERY TO ENSURE COMPLIANCE WITH THE CONTRACT DOCUMENTS AND TO ENSURE THAT PRODUCTS ARE UNDAMAGED AND PROPERLY PROTECTED. D. STORE PRODUCTS SUBJECT TO DAMAGE BY WEATHER CONDITIONS ABOVE GROUND, UNDER COVER IN WEATHER TIGHT ENCLOSURE WITH VENTILATION ADEQUATE TO PREVENT CONDENSATION. MAINTAIN TEMPERATURE AND HUMIDITY WITHIN RANGE REQUIRED BY MANUFACTURER'S INSTRUCTIONS. E. CLOSE OPEN ENDS OF EQUIPMENT AND WORK WITH TEMPORARY COVERS OR PLUGS DURING STORAGE AND CONSTRUCTION TO PREVENT ENTRY OF FOREIGN MATERIAL. PART 2 - PRODUCTS 2.1 MATERIALS A. MATERIALS SHALL BE NEW AND OF MANUFACTURERS SPECIFIED HEREIN. THEY SHALL BE U.S. MADE AND BEAR THE UL, ETL OR CSA LABELS WHERE POSSIBLE. 2.2 EQUIPMENT SUPPORTS A. SELECT AND SIZE SUPPORTS EXPANSION SHELLS AND BOLTS, CONCRETE INSERTS, AND ANCHOR BOLTS PER REQUIREMENTS FOR SEISMIC RESTRAINTS SPECIFIED IN SECTION 200548. HOT DIPPED OR MECHANICALLY GALVANIZED WHERE INSTALLED OUTDOORS UNLESS NOTED OTHERWISE ON THE DRAWINGS. DAMAGED GALVANIZED SURFACES REPAIRED WITH ZRC GALVILITE. 2.3 SLEEVES A. MATERIALS GENERAL: SCHEDULE 40 GALVANIZED STEEL PIPE WITH UNTHREADED ENDS, CAST IRON PIPE OR MINIMUM 26 GAGE GALVANIZED SHEET STEEL. USE STEEL PIPE FOR SLEEVES AT FLOOR SLABS. 2.4 PIPE MARKERS AND COLOR BANDS A. GENERAL: MANUFACTURER'S STANDARD PREPRINTED, FLEXIBLE OR SEMI -RIGID PERMANENT COLOR - CODED, PLASTIC SHEET PIPE MARKERS. COMPLY WITH ASME B. A13.1. SETONDA BRADY ,'E CRAFTMARK, MARKING SERVICES OR APPROVED. C. LETTERING: MANUFACTURER'S STANDARD PRE - PRINTED NOMENCLATURE WHICH BEST DESCRIBES PIPING SYSTEM IN EACH INSTANCE AS SELECTED BY THE A/E IN CASES OF VARIANCE WITH NAMES SHOWN OR SPECIFIED. 2.5 EQUIPMENT NAMEPLATES A. GENERAL: ENGRAVED STOCK MELAMINE PLASTIC LAMINATE. COMPLY WITH FS L -P -387. ENGRAVED WITH ENGRAVER'S STANDARD LETTER STYLE OF SIZES AND WORDING, BLACK WITH WHITE CORE (LETTER COLOR) EXCEPT AS OTHERWISE INDICATED. B. THICKNESS: 1/16 INCH FOR UNITS UP TO 20 SQ. IN. OR 8 INCH LENGTH AND 1/8 INCH FOR LARGER UNITS. 2.6 VALVE TAGS A. GENERAL: MANUFACTURER'S STANDARD SOLID PLASTIC VALVE TAGS WITH PRINTED ENAMEL LETTERING, PIPING SYSTEM ABBREVIATION IN APPROXIMATELY 3/16 INCH HIGH LETTERS. B. FASTENERS: MANUFACTURER'S STANDARD SOLID BRASS BEADED TYPE CHAIN LENGTH AS REQUIRED FOR PROPER ATTACHMENT OF TAGS TO VALVES MANUFACTURED SPECIFICALLY FOR THAT PURPOSE. 2.7 ACCESS TO FIRE SUPPRESSION, PLUMBING AND HVAC EQUIPMENT A. GENERAL: UNIVERSAL 1 -PIECE FRAME, FLUSH TYPE, WELDED STEEL GROUND SMOOTH ROUNDED SAFETY CORNERS, 1 -PIECE SPRING HINGE, SLOT SCREWDRIVER TYPE CAM LATCHES SHALLOW 1 -1 4 INCH MOUNTING FLANGE. WHERE LOCATED IN A PAINTED SURFACE AREA UNITS PRIMED FOR PAINTING• OTHERWISE POLISHED CHROME OR STAINLESS STEAL UNITS UNLESS ANOTHER TYPE OF FINISH IS INDICATED. B. UL COMPLIANCE: WHERE UL FIRE - RESISTANCE RATING IS INDICATED, DOORS UL LISTED AND LABELED EXCEPT FOR THOSE DOORS WHICH ARE SMALLER THAN MINIMUM SIZE REQUIRING FIRE RATINGS AS RECOGNIZED BY GOVERNING AUTHORITY. 2.8 PAINTING A. GENERAL: PAINTING OF WORK SPECIFIED IN MECHANICAL SECTIONS WHICH IS EXPOSED, INCLUDING EXTERIOR EXPOSED MECHANICAL WORK, IS SPECIFIED IN DIVISION 2.9 ROOF PENETRATIONS A. ROOF PENETRATIONS SHALL BE BY GENERAL CONTRACTOR AS NOTED ON THE ARCHITECTURAL DRAWINGS. PART 3 - EXECUTION 3.1 MEASUREMENTS A. VERIFY MEASUREMENTS AT JOB SITE. LOCATE EQUIPMENT AND FIXTURES ON CENTERS OTHERWISE. 0 CHECK `TSPACES, A NG, DUCTS, AND LOCATIONS ELEMENTS CLEARNOPENINGS. 3.2 INSTALLATION OF EQUIPMENT A. EQUIPMENT INSTALLATION: 1. GENERAL: INSTALL SUPPORTS FOR EQUIPMENT AND APPURTENANCES. 3.3 ACCESSIBILITY A. READILYLACCESSIBLVALVES, ITALL DAMPERS, CONTROLS, AND ACCESSIBILITY. TO BE B. EQUIPMENT: 1. INSTALL EQUIPMENT WHICH REQUIRES PERIODIC SERVICING OR REPAIRS TO BE READILY ACCESSIBLE. 3.4 PIPE PIPING, SAS, AND SSHALL NOT INTERFERE WITH REQUIRED ACCESS. A. INSTALL IDENTIFICATION AFTER COMPLETION OF COVERING AND PAINTING. 3.5 VALVE TAGS A. INSTALL VALVE TAGS ON VALVES AND CONTROL DEVICES IN EACH PIPING SYSTEM. 3.6 EQUIPMENT NAMEPLATES A. INSTALL NAMEPLATES ON OR NEAR EACH MAJOR ITEM. 3.7 PAINTING A. TOUCH -UP: COVER SCRATCHES ABRASIONS AND SIMILAR DAMAGES TO EQUIPMENT WITH FACTORY FINISHED SURFACES USING MATCHING FACTORY FURNISHED PAINT. B. GRILLES, REGISTERS AND DIFFUSERS: PAINT INSIDE SURFACE OF DUCTS, VISIBLE THROUGH GRILLES, REGISTERS DIFFUSERS AND OTHER OPENINGS WITH 1 COAT OF FLAT BLACK PAINT TO A POINT 2 FEET FROM OPENING ON STRAIGHT DUCTS OR AROUND BEND. SIMILARLY, PAINT PIPES AND CONDUITS VISIBLE THROUGH CEILING RELIEF GRILLES. 3.8 CLEANING AND HOUSEKEEPING A. REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, AND SIMILAR ITEMS, AT REGULAR INTERVALS. B. BEFORE SUBSTANTIAL COMPLETION CAREFULLY CLEAN EQUIPMENT, FIXTURES EXPOSED CUTTINGS, PAINT, PLASTER, MORTAR, ITEMS. TM LABELS, DIRT, DUST, END OF SECTIONSECTION 200513 - ELECTRICAL PROVISIONS PART 1 - GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: WORK INCLUDES FACTORY INSTALLED MOTORS AND MOTOR STARTERS AND ASSOCIATED APPURTENANCES. 1.2 QUALITY ASSURANCE A. CODES AND STANDARDS: 1. IEEE 112 IEEE STANDARD TEST PROCEDURE FOR POLYPHASE INDUCTION MOTORS AND GENERATORS. 2. NEMA MG 1, MOTORS AND GENERATORS. 3. NFPA 70, NATIONAL ELECTRICAL CODE (NEC). 1.3 SUBMITTALS A. PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR MOTORS. PART 2 - PRODUCTS 2.1 MOTORS A. MOTOR CHARACTERISTICS: EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE INDICATED AND EXCEPT WHERE REQUIRED ITEM OF PLUMBING AND HVAC EQUIPMENT CANNOT EE OBTAINED TO MEET REQUIREMENTS IN THIS ARTICLE, COMPLY WITH THE FOLLOWING REQUIREMENTS FOR MOTORS FOR PLUMBING AND HVAC WORK: 1. COMPLY WITH NEMA MG 1 UNLESS OTHERWISE INDICATED. 2. TEMPERATURE RATING: RATED FOR 40 C AMBIENT TEMPERATURE AND AT 3300 FOOT ELEVATION WITH MAXIMUM 50 C TEMPERATURE RISE FOR CONTINUOUS DUTY AT FULL LOAD CLASS A INSULATION). 3. CAPACITY AND TORQUE: SUFFICIENT TO START ACCELERATE, AND OPERATE CONNECTED LOADS AT DESIGNATED SPEEDS AT INSTALLED ALTITUDE AND ENVIRONMENT, WITH INDICATED OPERATING SEQUENCE BUT WITHOUT EXCEEDING NAMEPLATE RATINGS OR CONSIDERING SERVICE FACTOR. 4. PHASES AND CURRENT CHARACTERISTICS: SQUIRREL -CAGE INDUCTION POLYPHASE MOTORS FOR 1/2 HP AND LARGER. PERMANENT -SPLIT CAPACITOR OR CAPACITOR-START SINGLE -PHASE MOTORS FOR 1/3 HP AND SMALLER, EXCEPT 1/6 HP AND SMALLER MAY AT EQUIPMENT MANUFACTURER'S OPTION BE SPLIT-PHASE TYPE. COORDINATE CURRENT CHARACTERISTICS WITH POWER SPECIFIED IN DIVISION 26 SECTIONS AND WITH INDIVIDUAL EQUIPMENT REQUIREMENTS. 5. DO NOT PURCHASE MOTORS UNTIL POWER CHARACTERISTICS AND ROTATION DIRECTION HAVE BEEN CONFIRMED. 6. SERVICE FACTOR: 1.15 FOR POLYPHASE MOTORS AND 1.35 FOR SINGLE -PHASE MOTORS. B. MOTOR CONSTRUCTION: GENERAL PURPOSE, CONTINUOUS DUTY MOTORS, DESIGN "B ", EXCEPT "C" WHERE REQUIRED FOR HIGH STARTING TORQUE. 1. FRAMES: NEMA STANDARD. 2. BEARINGS: ANTIFRICTION BALL OR SLEEVE BEARINGS WITH INNER AND OUTER SHAFT SEALS GREASEABLE EXCEPT PERMANENTLY SEALED WHERE MOTOR IS NORMALLY INACCESSIBLE FOR REGULAR MAINTENANCE. WHERE BELT DRIVES AND OTHER DRIVES PRODUCE LATERAL OR AXIAL THRUST IN MOTOR, BEARINGS DESIGNED TO RESIST THRUST LOADING. REFER TO DIVISIONS 22 AND 23 SECTIONS FOR FRACTIONAL -HP LIGHT -DUTY MOTORS WHERE SLEEVE -TYPE BEARINGS ARE PERMITTED. 3. ENCLOSURE TYPE: EXCEPT AS OTHERWISE INDICATED OPEN DRIPPROOF MOTORS FOR INDOOR USE WHERE SATISFACTORILY HOUSED, AND GUARDED DRIPPROOF MOTORS WHERE EXPOSED TO CONTACT BY EMPLOYEES AND BUILDING OCCUPANTS. TOTALLY ENCLOSED FAN COOLED FOR OUTDOOR USE. 4. OVERLOAD PROTECTION: INCLUDE FOR EACH MOTOR. BUILT -IN (MANUAL RESET) FOR 120, 208, AND 277 VOLT, SINGLE PHASE MOTORS. 5. EFFICIENCY: MOTORS ARE TO BE "ENERGY EFFICIENT" HAVING MINIMUM EFFICIENCY AS SCHEDULED IN ACCORDANCE WITH IEEE 112, TEST METHOD B. 6. POWER FACTOR: MINIMUM 85 PERCENT UNDER FULL LOAD CONDITIONS. WHERE LESS THAN 85 PERCENT, INCLUDE POWER FACTOR CORRECTION TO MINIMUM 90 PERCENT. C. MANUFACTURERS: EXCEPT WHERE ITEM OF PLUMBING AND HVAC EQUIPMENT (WHICH OTHERWISE COMPLIES WITH REQUIREMENTS IN THIS SECTION) IS INTEGRALLY EQUIPPED WITH MOTOR PRODUCED BY ANOTHER MANUFACTURER, INCLUDE MOTORS BY ONE OF THE FOLLOWING MANUFACTURERS: BALDOR ELECTRIC CO., GENERAL ELECTRIC CO., RELIANCE ELECTRIC MOTORS, OR SQUARE D. 2.2 MOTOR STARTERS A. GENERAL: COMPLY WITH REQUIREMENTS IN DIVISION 26 FOR FACTORY INSTALLED STARTERS. FIELD INSTALLED STARTERS ARE SPECIFIED IN DIVISION 26 WORK. PART 3 - EXECUTION 3.1 MOTORS A. WHERE MOTORS ARE FURNISHED FOR FIELD MOUNTING, INSTALL MOTORS ON MOTOR MOUNTING SYSTEMS IN ACCORDANCE WITH MOTOR MANUFACTURER'S INSTRUCTIONS, SECURELY ANCHORED N MECRESIST L TORQUE, SECURE SHEAVES AND OTHER DRIVE UNITS TO MOTOR SHAFTS WITH KEYS AND ALLEN SET SCREWS EXCEPT MOTORS OF 1/3 HP AND LESS MAY BE SECURED WITH ALLEN SCREWS ON FLAT SURFACES OF SHAFT UNLESS OTHERWISE INDICATED, SET MOTOR SHAFTS PARALLEL WITH MACHINE SHAFTS. 3.2 STARTERS A. COORDINATE WITH DIVISION 26 WORK TO INSTALL STARTERS AND WIRING DEVICES NEAR MOTORS OR AS INDICATED ON THE DRAWINGS. SECURELY SUPPORT AND ANCHOR IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. LOCATE FOR PROPER OPERATIONAL ACCESS INCLUDING VISIBILITY FOR SAFETY. 3.3 EQUIPMENT AND MOTOR CONNECTIONS A. INSTALL FLEXIBLE - CONDUIT CONNECTION TO MOTOR AND EQUIPMENT FOR PACKAGED AND NON- PACKAGED EQUIPMENT THAT IS FACTORY ASSEMBLED. COMPLY WITH APPLICABLE PROVISIONS OF DIVISION 26 SECTIONS FOR WIRING MATERIALS AND WIRING SERVICES. B. REFER TO DIVISION 26 SECTIONS FOR INSTALLATION REQUIREMENTS. DIVISIONS 22 AND 23 SHALL PROVIDE WORK NOT INDICATED IN DIVISION 26 FOR A COMPLETE AND OPERATING SYSTEM. WHERE A CONFLICT OCCURS BETWEEN DIVISIONS 22 AND 23 AND DIVISION 26 DIVISION 22 OR 23 SUB - CONTRACTOR SHALL PROVIDE WORK FOR A COMPLETE AND OPERATING SYSTEM. END OF SECTION SECTION 200548 - VIBRATION ISOLATION AND SEISMIC CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: WORK INCLUDES PRODUCTS TO ISOLATE BUILDING STRUCTURE AND OCCUPIED SPACES FROM VIBRATION TRANSMISSION N AND INCLUDES SEISMIC RESTRAINTS FOR PLUMBING AND HVAC EQUIPMENT AND DISTRIBUTION SYSTEMS. 1.2 SUBMITTALS A. PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND INSTALLATION INSTRUCTIONS FOR EACH VIBRATION ISOLATOR, BASE, SEISMIC RESTRAINT, AND APPURTENANCE. B. CALCULATIONS: SIZING AND WEIGHT DISTRIBUTION FOR VIBRATION ISOLATORS, BASES, AND SEISMIC RESTRAINTS. C. VIBRATION ISOLATION BASE DETAILS: DETAIL FABRICATION INCLUDING ANCHORAGES AND ATTACHMENTS TO STRUCTURE AND TO SUPPORTED EQUIPMENT. D. SEISMIC RESTRAINT DETAILS: DETAIL FABRICATION AND ATTACHMENT OF SEISMIC RESTRAINTS. E. ISOLATOR SCHEDULE LIST: LIST SIZE, TYPE, LOAD, AND STATIC DEFLECTION OF EACH ISOLATOR. 1.3 CONTRACTOR RESPONSIBILITY FOR VIBRATION ISOLATION AND SEISMIC RESTRAINTS A. GENERAL: A SINGLE SUPPLIER SHALL SELECT AND FURNISH ISOLATION MOUNTS PADS, SEISMIC RESTRAINTS SWAY BRACES, RELATED HARDWARE, AND FABRICATE ISOLATION BASES FOR THE PROJECT UNLESS OTHERWISE SPECIFIED. PART 2 - PRODUCTS 2.1 GENERAL A. MANUFACTURERS: MASON INDUSTRIES, AMBER /BOOTH, KINETICS NOISE CONTROL, VIBRATION MOUNTINGS & CONTROLS, VIBRO - ACOUSTICS, CALIFORNIA DYNAMICS CORP PART (3ALD IN), TOLLTO, OR APPROVED. MASON INDUSTRIES MODEL NUMBERS ARE LISTED. 3.1 INSPECTION A. DESCRIPTION: VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK OF THIS SECTION. DO NOT INSTALL UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. 3.2 EQUIPMENT A. SPRING MOUNTS: 1. MARK VIBRATION ISOLATORS TO SHOW UNDEFLECTED HEIGHT TO VERIFY PROPER ISOLATION AFTER INSTALLATION. INSTALL ISOLATORS FOR SINGLE PIECE OF EQUIPMENT WITH APPROXIMATELY EQUAL DEFLECTION. MOUNT EQUIPMENT LEVEL. 2. COORDINATE WITH GENERAL CONTRACTOR AND STRUCTURAL ENGINEER TO ENSURE PROPER MOUNTING ATTACHMENT POINTS FOR SEISMIC RESTRAINED SPRINGS. B. SPRING HANGER RODS: ALIGN ISOLATOR TO CLEAR ISOLATOR HOUSING. INSTALL HOUSING AS CLOSE AS POSSIBLE TO STRUCTURE. C. BASES: 1. ATTACH CURB MOUNTED ISOLATION BASE AND RIGID ROOF CURB TO ROOF STRUCTURE AND ATTACH ROOFTOP HVAC UNIT TO CURB IN ACCORDANCE WITH ENGINEER, MANUFACTURERS' RECOMMENDATIONS, SPECIALTY CONSULTANT OR SEISMIC RESTRAINT DEVICE MANUFACTURER'S DESIGN. 3.3 DUCTWORK A. DUCT CLEARANCE: INSTALL VIBRATION - ISOLATED DUCTS TO ALLOW MINIMUM 2 INCH GAP BETWEEN TOP OF DUCT AND UNDERSIDE OF FLOOR STRUCTURE ABOVE. B. VIBRATION ISOLATOR HOUSING: INSTALL AS CLOSE AS POSSIBLE STRUCTURE. C. FLEXIBLE CONNECTORS: INSTALL IN DUCTS AT CONNECTIONS TO EQUIPMENT. D. DUCTS WITHIN SHAFTS: INSTALL WITHOUT CONTACT WITH WALLS. ANCHOR TO BUILDING STRUCTURE AT FLOOR ONLY. 3.5 EQUIPMENT, PIPING, AND DUCT SEISMIC RESTRAINTS A. GENERAL: COMPLY WITH REQUIREMENTS IN IBC AND ASCE 7 -05 UNLESS OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS. B. COORDINATION: COORDINATE WITH SUBMITTALS AND SHOP DRAWINGS OF PLUMBING AND HVAC EQUIPMENT SUCH AS AIR HANDLING UNITS. COORDINATE WITH GENERAL CONTRACTOR AND STRUCTURAL ENGINEER TO ENSURE CORRECT MOUNTING ATTACHMENT POINTS. C. VIBRATION - ISOLATED EQUIPMENT, PIPING, AND DUCTS: 1. INSTALL SEISMIC RESTRAINTS WITH FACTORY SET CLEARANCES. INSTALL SEISMIC RESTRAINT TO AVOID SHORT CIRCUITING OF VIBRATION ISOLATORS. 2. ISOLATE BOLTS FROM DIRECT CONTACT WITH STRUCTURE. 3.7 ELECTRICAL CONNECTIONS TO VIBRATION ISOLATED EQUIPMENT A. COMPLY WITH REQUIREMENTS IN SECTION 200513. B. DO NOT INSTALL CONDUIT CLAMPS OR HANGERS BETWEEN FLEXIBLE RACEWAY TERMINATION AND EQUIPMENT CONNECTION. C. RECOMMENDED MINIMUM FLEXIBLE RACEWAY LENGTH IS 6 FEET. END OF SECTION SECTION 200593 - TESTING, ADJUSTING, AND BALANCING PART 1 - GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: WORK INCLUDES TESTING, ADJUSTING, AND BALANCING (TAB) OF MECHANICAL SYSTEMS. 1.2 QUALITY ASSURANCE A. CODES AND STANDARDS: 1. NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR - CONDITIONING AND VENTILATING SYSTEMS. 2. UL 873, STANDARD FOR TEMPERATURE - INDICATING AND TEMPERATURE - REGULATING EQUIPMENT. B. TAB SUBCONTRACTOR: 1. GENERAL: TAB WORK PERFORMED BY AN INDEPENDENT SUBCONTRACTOR, NOT AFFILIATED WITH THE CONTRACTOR. LANDLORD MAY REQUIRE SPECIFIC CONTRACTOR FOR BALANCING. 2. (QUALIFICATIONS: CERTIFIED BY NATIONAL ENVIRONMENTAL BALANCING BUREAU 3. EXPERIENCEAS ASSOCIATED AIR YEARS BALANCE PROJECTS (OFB SIMILAR SCOPE AND COMPLEXITY. 1.3 SUBMITTALS A. BALANCING REPORT: 1. PROVIDE COMPLETE BALANCING REPORT IN ACCORDANCE WITH NEBB REQUIREMENTS: PART 2 - PRODUCTS 2.1 INSTRUMENTS A. GENERAL: FURNISH MATERIALS AND EQUIPMENT NECESSARY TO PERFORM THE WORK. B. INSTRUMENTATION: USE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. PART 3 - EXECUTION 3.1 INSPECTION A. DESCRIPTION: VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK OF THIS SECTION. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. 3.2 WORK BY TAB SUBCONTRACTOR A. GENERAL: ADJUST QUANTITIES TO WITHIN 10 PERCENT OF DESIGN VALUES: B. FOR ROOMS AND TERMINAL UNITS THAT ARE IDENTIFIED TO MAINTAIN NEGATIVE PRESSURE RELATIONSHIPS TO ADJACENT ROOMS, ADJUST AIR QUANTITIES TO WITHIN THE PERCENT OF DESIGN VALUES. C. SYSTEMS: INCLUDE BUT ARE NOT LIMITED TO SUPPLY, RETURN, EXHAUST, AND VENTILATION AIR SYSTEMS. D. EXISTING SYSTEMS: PERFORM TAB FOR EXISTING AIR HANDLING SYSTEMS (NOTED ON PLANS), WORK SHALL INCLUDE SAME ACTIVITIES AS FOR NEW SYSTEM. E. FILTER PRESSURE DROP: FOLLOWING PROPORTIONAL ADJUSTMENT OF SUPPLY AIR OUTLETS MEASURE INITIAL CLEAN FILTER PRESSURE DROP. SIMULATE FILTER LOADING BY COVERING FACE OF FILTERS TO INCREASE FILTER PRESSURE DROP. REMEASURE CLEAN FILTER PRESSURE DROP AT FINAL FAN SETTING. F. FAN ADJUSTMENT AND DRIVE CHANGES: MECHANICAL SUB CONTRACTOR SHALL PROVIDE MOTORS, SHEAVES AND BELTS AS REQUIRED FOR BALANCER TO ACCOMPLISH WORK. G. OUTDOOR AIR/ECONOMIZER CYCLES: AFTER SUPPLY AIR OUTLETS AND RETURN AIR INLETS AIR QUANTITYYAINDICATED AND AIR DRAWINGS OFOR CEACHD SYSTE OUTDOOR AIR DAMPER H. MARKING OF ADJUSTMENTS: 1 ANDS OTHERLADJUSTMENT AND RECHECK, ALLOW PERMANENTLY MARK DAMPERS, VALVES, DISTURBED IN THE FUTURE. END OF SECTION SECTION 200700 - MECHANICAL INSULATION PART 1 - GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: WORK INCLUDES INSULATION FOR PLUMBING AND HVAC PIPING, DUCTWORK AND EQUIPMENT. 1.2 QUALITY ASSURANCE A. CODES AND STANDARDS: 1. APPLICABLE ENERGY CODE. 2. ASTM E 84, STANDAR TT METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. 3. ASTM E 96, STANDARD TEST METHODS FOR WATER VAPOR TRANSMISSION OF MATERIALS. 4. NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR - CONDITIONING AND VENTILATING SYSTEMS. 5. ULP7355ST FOR UFAEGUNNG CTSS OF AD 6. 2TE S RCBRICHARAERITIC MATERIALS. MATERIALS. 1.3 SUBMITTALS A. PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA FOR EACH TYPE OF REQUIRED INSULATION. 1.4 SURFACE BURNING CHARACTERISTICS A. PROVIDE COMPOSITE OR COMPONENT RATINGS PER NFPA 255 ASTM E 84 AND UL 723 AS FOLLOWS: FLAME SPREAD RATING NOT GREATER THAN 25 AND SMOKE DEVELOPED RATING NOT GREATER THAN 50. B. COMPOSITE INCLUDES INSULATION, JACKETING, AND ADHESIVE USED TO SECURE JACKETING OR FACING. C. COMPONENTS INCLUDE PVC JACKETING AND FITTINGS, ADHESIVE, MASTIC, CEMENT, TAPE, AND CLOTH. PART 2 - PRODUCTS 2.1 MATERIALS A. FIBERGLASS PIPE INSULATION: ASTM C 547, TYPE 1. B. FIBERGLASS PIPE FITTING INSULATION: THERMAL BLANKET, ASTM C 533, TYPE I OR II. C. CALCIUM SILICATE PIPE INSULATION: ASTM C 533 TYPE 1. D. FIBERGLASS DUCT INSULATION: ASTM C 553, TYPE I, II, OR III, ASTM C 1290, ASTM C 1139 TYPE III FACED)) ASTM 4 E. ADHESIVES, SEALERS STALES, E 8 ,AND ASTM C 1136 TYPE II FOR FSK JACKET. RECOMMENDED BY INSULATION MANUFACTURER AND APPLICATIONS VINDICATED. 2.2 MANUFACTURERS A. FIBERGLASS PIPE AND DUCT INSULATION: CERTAINTEED, KNAUF INSULATION, JOHNS PNGI EMESLA G, OR APPROVED. 2.3 PIPING SYSTINUION A. INSULATION MATERIALS AND THICKNESSES SHALL MEET OR EXCEED THE INSULATION REQUIREMENTS OF THE APPLICABLE ENERGY CODE. WHERE INSULATION THICKNESS SPECIFIED IS LARGER THAN THOSE LISTED IN THE APPLICABLE ENERGY CODE, USE THE LARGER VALUES. B. INSULATE COLD PLUMBING WITH FIBERGLASS, 1 INCH THICK FOR ALL SIZES. C. INSULATE HOT PLUMBING PIPING WITH THE 1 INCH THICK FOR PIPE SIZES 2 INCHES AND SMALLER. D. INCREASE THICKNESS BY 1/2 INCH WHERE PIPING IS LOCATED OUTDOORS OR OTHERWISE EXPOSED TO AMBIENT AIR. E. INCLUDE FACTORY APPLIED ASJ /SSL ON FIBERGLASS PIPING INSULATION. 2.4 DUCT SYSTEM INSULATION A. DUCT WRAP: FLEXIBLE FIBERGLASS DUCT WRAP INSULATION WITH FACTORY APPLIED FSK FACING (VAPOR BARRIER) CONSISTING OF ALUMINUM FOIL REINFORCED WITH FIBERGLASS SCRIM LAMINATED TO UL RATED KRAFT. B. INSULATE ALL SUPPLY, RETURN AND OUTSIDE AIR DUCTWORK WITH FSK GLASS FIBER INSULATION HAVING A MINIMUM R -VALUE OF 7 AND VAPOR BARRIER JACKET. 2.5 JACKETING A. METAL: .016 INCH THICK ALUMINUM OR .1 IN THICK STAINLESS STEEL WITH MOISTURE BARRIER ON INNER SURFACE. ASTM B 209. PART 3 - EXECUTION 3.1 INSPECTION A. GENERAL: VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK OF THIS SECTION. DO NOT INSTALL UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. B. CUT INSULATION SLIGHTLY LONGER THAN CIRCUMFERENCE OF DUCT TO INSURE FULL THICKNESS AT CORNERS. APPLY INSULATION WITH EDGES TIGHTLY STITCHED WITH STAPLES. TAPE STITCHED SEAM WITH 3 INCH WIDE PRESSURE SENSITIVE ALUMINUM FOIL TAPE OR SEAL JOINTS WITH 2 COATS OF VAPOR BARRIER MASTIC REINFORCED WITH ONE LAYER OF OPEN WEAVE GLASS FABRIC. A. SECURE INSULATION TO BOTTOM OF RECTANGULAR AND SQUARE DUCTS 18 INCHES AND WIDER WITH WELDED PINS AND SPEED CLIPS ON 18 INCH CENTERS. CUT OFF PROTRUDING ENDS OF THE PINS FLUSH AFTER SPEED CLIPS HAVE BEEN INSTALLED. SEAL VAPOR BARRIER FACING WHERE PINS HAVE PIERCED THROUGH WITH TAPE OF SAME MATERIAL BY APPLYING VAPOR BARRIER ADHESIVE TO BOTH SURFACES AS RECOMMENDED BY THE MANUFACTURER. B. INSTALL DUCT WRAP WITH MAXIMUM 25 PERCENT COMPRESSION. C. EXHAUST DUCTS UNINSULATED. D. SEAL OTHER JOINTS AND PENETRATIONS OF THE VAPOR BARRIER FACING WITH 3 INCH WIDE PRESSURE SENSITIVE ALUMINUM FOIL TAPE. SEAL CUTS OR TEARS WITH STRIPS OF THE ALUMINUM FOIL TAPE. E. OUTDOOR EXPOSED CONDITIONED AIR DUCTS: 1. INSTALL WEATHERPROOF MASTIC AND GLASS CLOTH PER MANUFACTURER'S RECOMMENDATIONS. 2. LOCATE JOINTS AND LONGITUDINAL SEAMS OF S 0 METAL JACKETING TO SHED WATER MINIMUM 3 INCH H OVERLAP, P, WEATHER SEALED. INSTALL STRAPS OVER 2 INCH WIDE BUTT STRIPS ON END OF SECTION SECTION 200820 - SYSTEMS OPERATIONS AND MAINTENANCE MANUALS PART 1 - GENERAL 1.1 SECTION INCLUDES G. DESCRIPTION: WORK INCLUDES PREPARATION OF MECHANICAL SYSTEMS OPERATION AND MAINTENANCE MANUALS. 1.2 SCOPE OF WORK A. PRODUCT DATA AND PARTS LIST: INCLUDE LOCAL SOURCE OF SUPPLY FOR PARTS AND REPLACEMENT. LIST PARTS AND COMPONENTS OF EQUIPMENT STATING CATALOG NUMBER (SERIAL NUMBER AND RATINGS, SUCH AS HP, VOLTAGE, AND GPM.) AND SIZE OF PART USED IN R ON I 0 N EQU PMENT. B. TROUBLESHOOTING GUIDE. C. MANUFACTURER'S INSTALLATION AND SERVICE INSTRUCTIONS. D. MANUFACTURER'S SERVICE INSTRUCTIONS. E. START -UP INSTRUCTIONS WITH CERTIFICATES OF START -UP AND VERIFICATION. F. FINAL APPROVED SUBMITTALS. G. WARRANTIES. PART 2 - PRODUCTS 2.1 FORMAT A. ASSEMBLE OPERATION AND MAINTENANCE MANUAL IN 3 -RING BINDER(S). END OF SECTION REVIEWED FOR- / CODE COMPLIANCE AD mnifE. DEC 1 u 2U1U City of Tukwila BUILDING DIVIsirw RECEIVED OCT 13 2010 PERMIT CENTER U a MECHANICAL SPECIFICATIONS 0 N REVISIONS (0 0 N_ M O • (r) ct .y cci co N N cc Z _O F- a_ Z 2 2 ›- g • I- O ,J H W U w W U CL J�/ 1 W Z Lowii a 0 W ■� E-- U 12844 MILITARY ROAD S TECTURE NAC NO 121 -10017 HEINO 10113 DRAWN JMR CHECKED RKE DATE 9 -10 -2010 2201 SIXTH AVENUE1 SUITE 14051 SEATTLE WA 98121-1847 1 P: 206.441.4522 F:206.442.7917 rn z 0 c o ai w % (n C c0 O O O O � CV O � cd _ F_ iwn- I O �Z W< Qw r z O J a,� DIVISION 20 CONTINUED SECTION 202110 - PIPING PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES PIPING AND ASSOCIATED APPURTENANCES FOR PIPING THAT APPLY TO MULTIPLE SYSTEMS. PIPING SPECIFIC TO A SINGLE SYSTEM IS SPECIFIED IN THAT PARTICULAR SECTION. 1.2 QUALITY ASSURANCE A.CODES AND STANDARDS: 1. ASME B31.1, POWER PIPING. 2.ASME 831.9, BUILDING SERVICES PIPING. 1.3 SUBMITTALS A.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH TYPE OF PIPING FITTINGS AND ASSOCIATED APPURTENANCES. B.TESTING REPORTS: PRESSURE TESTING RECORDS. PART 2 - PRODUCTS 2.1 GENERAL A.PRESSURE RATINGS: PROVIDE COMPONENTS WITH MINIMUM PRESSURE RATING OF 125 PSIG WORKING PRESSURE. 2.2 MANUFACTURERS A.COPPER TUBING: CERRO, MUELLER, WOLVERINE. B.COPPER TUBE FITTINGS: NIBCO®, MUELLER ELKHART. C.GASKETS: CRANE, GARLOCK U. S. RUBBER, ANCHOR, FLEXITALLIC. D.SHAPED NIPPLES: ALLIED, BONNEY FORGE. 2.3 COPPER TUBING A.TUBING, ABOVE GRADE: TYPE L COPPER WATER TUBE HARD - DRAWN, ASTM B 88. B.TUBING UNDERGROUND: TYPE K COPPER WATER TUBS SOFT -DRAWN ASTM B 88. C.FITTINGS: WROUGHT COPPER SOLDER FITTINGS AND SCREWED ADAPTERS, ASME 816.22; CAST BRONZE SOLDER JOINT FITTINGS AND SCREWED ADAPTERS, ASME B16.18. D.UNIONS: WROUGHT COPPER SOLDER JOINT UNIONS, ASME B 16.22; CAST BRONZE SOLDER JOINT FITTINGS, ASME B 16.18. E.FLANGES AND FLANGED FITTINGS: CAST BRONZE, 125 POUND CLASS, ASME STANDARDS. F. APPLICABLE 1/16 INCH AND COMPRESSED NON-ASBESTOS INSTALLED IALFULL,FACE FOR GASKETS FOR FLAT FACED FLANGES. G.JOINT COMPOUND: TEFLON TAPE. H.SOLDER MATERIAL: 95 PERCENT TIN, 5 PERCENT ANTIMONY SOLDER OR 96 PERCENT TIN 4 PERCENT SILVER CONFORMING TO ASTM B 32. J.W. HARRIS "BRIDGIT ", HARDY Sc HARMAN ALLSTATE OR APPROVED. PART 3 - EXECUTION 3.1 PIPING INSTALLATION A.INSTALL PIPING FITTINGS AND APPURTENANCES IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES WHICH WILL ACHIEVE PERMANENTLY LEAKPROOF PIPING SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE WITHOUT PIPING FAILURE. B.INSTALL PIPE GENERALLY SLOPED TO PERMIT DRAINAGE AT LOW POINTS, FREE FROM SAGS, BENDS, AND TRAPS, AND IN A MANNER TO CONSERVE SPACE FOR OTHER WORK. 3.2 FLUSHING A.FLUSH PIPING WITH CLEAN WATER PRIOR TO CONNECTING TO EXISTING SYSTEMS AND PRESSURE TESTING. 3.3 PRESSURE TESTING A.TEST PIPING SYSTEMS BEFORE INSULATION HAS BEEN APPLIED AND BEFORE BACKFILLING. B.TEST PRESSURES AND DURATION: TEST PIPING SYSTEMS AT PRESSURE OF 1-1/2 TIMES I IN TESTS PRESSURE FOR RSUFFICIENTRTIME TO PERMITWCOMPLETE INSPECTION OF SYSTEM UNDER TEST. MINIMUM 2 HOUR DURATION. TEST IN SECTIONS AND TEST ENTIRE SYSTEM WHEN COMPLETELY INSTALLED. C.TEST REPAIRS: 1. REMOVE MATERIALS SUCH AS GASKETS AND BOLTS DAMAGED DURING TESTS AND FLUSHING AND PROVIDE NEW COMPONENTS. 2.USE NEW GASKETS EACH TIME A FLANGED JOINT IS MADE UP. 3.REPAIR DEFECTS WHICH DEVELOP DURING TESTING AND RETEST PIPING SYSTEMS UNTIL THEY SHOW NO DEFECT OR WEAKNESS AND ARE TIGHT. DO NOT USE CHEMICALS, STOP -LEAK COMPOUNDS MASTICS, OR OTHER TEMPORARY REPAIR METHODS. D.TEST RECORDS: MAKE AND SUBMIT RECORDS FOR EACH PIPING INSTALLATION. INCLUDE COPIES IN THE OPERATION AND MAINTENANCE MANUAL. END OF SECTION SECTION 202115 - PIPING SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES PIPE HANGERS AND SUPPORTS, STRAINERS, THERMOMETERS, PRESSURE GAGES, TEMPERATURE /PRESSURE TEST PORTS (PETE'S PLUGS AIR VENTS ALIGNMENT GUIDES, AND ASSOCIATED APPURTENANCES FOR PIPING THAT PLUGS), TO MULTIPLE SYSTEMS. SPECIALTY COMPONENTS SPECIFIC TO A SINGLE SYSTEM ARE SPECIFIED IN THAT PARTICULAR SECTION. 1.2 QUALITY ASSURANCE A.CODES AND STANDARDS: 1.ASME B31.1, POWER PIPING. 2.ASTM E 84, STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. 3.NFPA 255 SURFACE BURNING CHARACTERISTICS BUILDING MATERIALS. 4.UL 723 TEST FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. B.MSS COMPLIANCE: COMPLY WITH MSS SP -58 FOR MATERIALS DESIGN, AND MANUFACTURE OF PIPE HANGERS AND SUPPORTS. COMPLY WITH MSS SP -69 FOR SELECTION AND APPLICATION OF PIPE HANGERS AND SUPPORTS. COMPLY WITH MSS SP -89 FOR FABRICATION AND INSTALLATION OF PIPE HANGERS AND SUPPORTS. REFER TO MSS SP -90 FOR TERMINOLOGY USED IN THIS SECTION. C.PIPE HANGERS AND CLAMPS AND RELATED COMPONENTS INSTALLED IN CEILING SPACES USED AS A RETURN AIR PLENUM SHALL HAVE RATINGS PER NFPA 255, ASTM E 84, AND UL 723 WITH FLAME SPREAD RATING NOT GREATER THAN 25 AND SMOKE DEVELOPED RATING NOT GREATER THAN 50. PART 2 - PRODUCTS 2.1 GENERAL A.FURNISH FACTORY- FABRICATED PIPING SPECIALTIES PIPE HANGERS PIPE SUPPORTS, ESCUTOCRHEONS,RECOMMENDED 'BY THERMOMETERS, PRESSURE FOR USE GAUGES AND B.MATERIALS: MATCH PIPING MATERIAL AT POINT OF CONTACT WITH PIPING. PART 3 - EXECUTION 3.1 PIPE HANGERS AND SUPPORTS A.GENERAL: INSTALL BUILDING ATTACHMENTS AT REQUIRED LOCATIONS WITHIN CONCRETE OR ON STRUCTURE STEEL FOR PROPER PIPING SUPPORT. INSTALL ADDITIONAL SUPPORTS AT CONCENTRATED LOADS, INCLUDING VALVES FLANGES, GUIDES, STRAINERS, EXPANSION JOINTS AND AT CHANGES IN DIRECTION OF PIPING. B.INSTALL HANGERS AND SUPPORTS COMPLETE WITH NECESSARY INSERT, BOLTS, RODS, NUTS WASHERS AND OTHER ACCESSORIES. 3.2 DIELECTRIC UNIONS AND NIPPLES A.INSTALL AT THE FOLLOWING LOCATIONS: 1. AT BLACK AND GALVANIZED STEEL PIPING CONNECTIONS TO COPPER TUBING. 2.AT BLACK STEEL PIPING CONNECTIONS TO BRONZE VALVES AND SIMILAR DEVICES. 3.3 PIPE ESCUTCHEONS A.INSTALL ESCUTCHEONS AT WALL, FLOOR AND CEILING PENETRATIONS IN EXPOSED FINISHED LOCATIONS AND WITHIN CABINETS AND MILLWORK. USE DEEP - PATTERN ESCUTCHEONS IF REQUIRED TO CONCEAL PROTRUDING PIPE FITTINGS. ESCUTCHEONS NOT REQUIRED WHERE SLEEVES PROJECT ABOVE FLOOR. END OF SECTION DIVISION 21 SECTION 211000 - AUTOMATIC FIRE SUPPRESSION SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES DESIGN AND CONSTRUCTION OF COMPLETE AUTOMATIC WET FIRE SUPPRESSION SYSTEMS BY EXTENDING EXISTING SYSTEM TO SERVE AFFECTED AREA. B.GENERAL REQUIREMENTS: DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS, DIVISION 01, AND SECTIONS 200500 AND 200510 APPLY TO WORK IN THIS SECTION. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY, AND STATE CODES AND ORDINANCES. B.AUTHORITIES HAVING JURISDICTION (AHJS): C.LOCAL FIRE DEPARTMENT. D.CODES AND STANDARDS: NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS AND LOCAL JURISDICTION REQUIREMENTS. E. FIRE SPRINKLER SYSTEM CONTRACTOR'S QUALIFICATIONS FOR PREPARATION OF SHOP DRAWINGS INSTALLATIONS INSPECTIONS, MAINTENANCE, AND SERVICING: ONLY LICENSED FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS SHALL EXECUTE CONTRACTS FOR INSTALLATION INSPECTION, MAINTENANCE OR SERVICING OF FIRE PROTECTION SPRINKLER SYSTEMS OR ANY PART OF SUCH SYSTEM. F. FIRE SPRINKLER SYSTEM CONTRACTOR'S QUALIFICATIONS: ACTIVE NICET LEVEL III (CERTIFIED ENGINEERING TECHNICIAN) CERTIFICATION IN FIRE PROTECTION ENGINEERING TECHNOLOGY AUTOMATIC SPRINKLER SYSTEM LAYOUT. G.TENANT CRITERIA: REVIEW MALL /TENANT CRITERIA FOR ADDITIONAL REQUIREMENTS AS THEY PERTAIN TO FIRE SPRINKLER SYSTEMS. 1.3 SYSTEM DESIGN CRITERIA A.DESIGN FURNISH AND INSTALL COMPLETE OPERABLE FIRE SUPPRESSION SYSTEMS IN ACCORDANCE WITH THE LATEST ADOPTED EDITIONS OF IBC, IFC, NFPA 13 AND APPLICABLE CITY, COUNTY, AND STATE LAWS, CODES AND STANDARDS. INCLUDE ACCESSSrOR ES TO MEETSREQUIREMENTS OF AHJS LOW AIR CODES AND STANDARDS. B.IN AREAS WHERE LOCAL CODES REQUIRE COVERAGE BY EITHER FIRE SPRINKLERS OR C.THETCONTRCATCOTOR PROVIDE COVERAGE SPRINKLERS. SHALL MEET WITH THE AHJS PRIOR TO PREPARATION OF SHOP DRAWINGS, HYDRAULIC CALCS AND EARTHQUAKE BRACING CALCULATIONS TO REVIEW PROCEDURES FOR HANDLING SUBMITTALS, INSPECTION, TESTING AND FOR GENERAL COORDINATION AND TO VERIFY SPRINKLER OCCUPANCY HAZARD CLASSIFICATIONS. D.OBTAIN LATEST WATER SUPPLY ENGINEERING TEST DATA PRIOR TO DESIGN. INCLUDE 10 PERCENT SAFETY MARGIN IN SYSTEM DESIGN. IF TEST DATA IS NOT AVAILABLE, CONDUCT TEST TO DETERMINE AVAILABLE FLOW AND PRESSURES TO HYDRAULICALLY DESIGN SYSTEM. E. COORDINATION WITH OTHER TRADES: 1. COORDINATE FIRE SUPPRESSION WORK WITH THAT OF MECHANICAL, SHEET METAL, PLUMBING, AND PING, CONDUITS DUCTS SAND S MISLAAR ITEMS BEST ARRANGEMENT OBTAINED. OF 2.IDENTIFY POINTS OF CONFLICTf BETWEEN THIS WORK AND THAT OF OTHER TRADES SO THAT CONFLICT MAY BE PROPERLY ADJUSTED. FIRE SUPPRESSION SYSTEM SUBCONTRACTOR SHALL REMOVE AND RE- INSTALL WORK WHICH INTERFERES WITH WORK OF OTHER TRADES AT NO ADDITIONAL COST TO THE OWNER. F. NO CHANGE ORDERS WILL BE ISSUED FOR ADDITIONS AND DELETIONS OF SPRINKLER HEADS AND ASSOCIATED PIPING EXCEPT AS SUCH ADDITIONS AND DELETIONS STEM FROM CHANGES IN BUILDING DESIGN MADE SUBSEQUENT TO APPROVAL OF SHOP DRAWINGS. 1.4 SUBMITTALS A.COMPLY WITH REQUIREMENTS IN DIVISION 01 AND SECTION 200500. B.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH ITEM SPECIFIED IN THIS SECTION. C.SHOP DRAWINGS AND CALCULATIONS: 1.COMPLY WITH REQUIREMENTS IN NFPA 13. 2.SUBMIT PRELIMINARY LAYOUT SHOWING ONLY HEAD LOCATIONS FOR REVIEW BY THE A/E. INCLUDE ADDITIONAL HEADS WHICH MAY BE REQUIRED FOR COORDINATED CEILING MAY EXCEED NO ADDITIONAL REQUIREMENTS .ONINDICATE,SPRINKLER NUMBER OF LOCATIONS AS FOLLOWS: a.SUSPENDED ACCESSIBLE CEILINGS: LOCATE HEADS IN CENTER OF CEILING TILES UP TO 2 FOOT TILE DIMENSION, AND 1/4 SECTION INTERVALS FOR 4 FOOT TILE DIMENSION. b.SUSPENDED INACCESSIBLE CEILINGS: LOCATE HEADS IN CONJUNCTION WITH LIGHT FIXTURES AND OTHER DEVICES INSTALLED IN CEILING IN A SYMMETRICAL PATTERN. c.ARRANGE HEADS IN STRAIGHT LINES THAT ARE PARALLEL AND PERPENDICULAR TO WALLS. 3.AFTER A/E REVIEW OF SPRINKLER HEAD LOCATIONS, SUBMIT SHOP DRAWINGS AND HYDRAULIC AND EARTHQUAKE BRACING CALCULATIONS TO THE A/E OF ENTIRE SPRINKLER SYSTEM. SHOP DRAWINGS INCLUDE COMPLETE FLOOR PLANS SHOWING NEW WORK AND SUFFICIENT EXTENT OF EXISTING WORK, LOCATIONS AND TYPES OF HEADS, PIPE SIZES AND CUTTING LENGTHS, LOCATIONS AND SIZES OF REQUIRED BEAM PENETRATIONS LOCATIONS AND TYPES OF HANGERS TEST VALVE(S), DRAIN VALVES, AND OTHER RELATED ITEMS. INDICATE EXPOSED WORK. 4.INCLUDE AR IVA VESFLOW SWITCHES, .VENTERS AND VAULTS, AND TAMPER COMPONENTS ST 5.INDICATE LOCATION OF ALARM AND SUPERVISORY INITIATING DEVICES AND OTHER DEVICES AND ELECTRICAL EQUIPMENT ASSOCIATED WITH THE FIRE SUPPRESSION SYSTEMS. 6.FOLLOWING REVIEW AND APPROVAL BY THE A/E SUBMIT SHOP DRAWINGS AND HYDRAULIC AND EARTHQUAKE BRACING CALC LAtIONS TO THE AHJS. DO NOT PROCEED WITH INSTALLATION UNTIL SHOP DRAWINGS HAVE BEEN APPROVED BY THE AHJS. D.CONTRACTOR'S MATERIAL AND TEST CERTIFICATE: SUBMIT TO CERTIFY MATERIAL SELECTION AND TESTING RESULTS USING FORM IN NFPA 13. COMPLETE APPLICABLE PORTIONS OF FORM AND SIGN AND DATE IT. E.OBTAIN FROM EACH AHJ WRITTEN CERTIFICATION THAT THE PERMANENT INSTALLATION HAS BEEN INSPECTED AND THAT IT COMPLIES WITH AHJS PUBLISHED REGULATIONS AND REQUIREMENTS. SUBMIT PRIOR TO SUBSTANTIAL COMPLETION. F. OPERATION AND MAINTENANCE DATA: 1 NSUNS H,' EOEDTTEKNSFEEITRCTIO WIT RECOMMENDED UNDERSTANDABLE, REQUIRED ES IGRQUNCY OF EQUIPMENT WITH METHODS FOR TESTING EQUIPMENT. INCLUDE TROUBLE - SHOOTING MANUAL. 2.PREPARE COMPLETE EASY -TO -READ UNDERSTANDABLE MAINTENANCE INSTRUCTIONS INCLUDING THE FOLLOWING INFORMATION: a.INSTRUCTION ON REPLACING COMPONENTS OF SYSTEM INCLUDING INTERNAL PARTS. b.LIST OF EQUIPMENT AND COMPONENTS WITH ADDRESS AND PHONE NUMBER OF BOTH MANUFACTURER AND LOCAL SUPPLIER OF EACH ITEM. 3.INCLUDE FIRE SUPPRESSION SYSTEM PRESSURE AND ALARM SYSTEM TESTS. 4.INCLUDE COPIES OF THE FOLLOWING PUBLICATIONS: a.NFPA 25 STANDARD FOR INSPECTION, TESTING, AND MAINTENANCE OF WATER BASED FIRE PROTECTION. 5.SUBMIT ONE WEEK MINIMUM PRIOR TO SYSTEM TRAINING. G.RECORD DRAWINGS: 1. PROVIDE IN ACCORDANCE WITH DIVISION 01 AND SECTION 200500. 2.SUBMIT ONE WEEK MINIMUM PRIOR TO SYSTEM TRAINING. PART 2 - PRODUCTS 2.1 MANUFACTURERS A.MANUFACTURER OF EQUIPMENT REGULARLY ENGAGED IN THE MANUFACTURE OF COMPONENTS SPECIFIED AND WITH PUBLISHED CATALOGS LISTING PERTINENT SPECIFICATIONS OF ITEMS MANUFACTURED. B.MANUFACTURERS NAME AND MODEL IDENTIFICATION USED THROUGHOUT THIS SECTION ARE TO ESTABLISH GENERAL CONFIGURATION, FUNCTION, SIZE, PERFORMANCE AND QUALITY. C.MANUFACTURERS: TYCO FIRE & BUILDING PRODUCTS (GRINNELL GROOVED PRODUCTS, CENTRAL SPRINKLER, GEM SPRINKLER, AND STAR SPRINKLER), THE VIKING CORP. RELIABLE AUTOMATIC SPRINKLER CO., GLOBE FIRE SPRINKLER CORP., OR APPROVED. 2.2 GENERAL A.EQUIPMENT MATERIAL, AND COMPONENTS REQUIRED BY NFPA TO BE LISTED: UL LISTED AND LABELED AND APPROVED BY FM AND AHJS. 2.3 PIPE AND FITTINGS A.PIPE: 1.COMPLY WITH REQUIREMENTS IN NFPA 13. 2.BLACK STEEL, ASTM A 53, ASTM A 135, OR ASTM A 795. 3.PIPE OTHER THAN SCHEDULE 40 OR SCHEDULE 10, ACCEPTABLE IF UL LISTED AND LABELED, FM APPROVED AND APPROVED BY AHJS. CPVC PIPE NOT ACCEPTABLE. 4.SCHEDULE 40 PIPE USED IN CUT GROOVE JOINTS. 5.SCHEDULE 10 PIPE USED FOR ROLLED GROOVED JOINTS. ROLLED GROOVED JOINTS FOR DRY PIPE SPRINKLER SYSTEMS NOT ACCEPTABLE. 6.INTERNAL AND EXTERNAL GALVANIZED STEEL FOR EXTERIOR PIPES, DRY PIPE SPRINKLER SYSTEMS, AND DRAINS. 7.FLEXIBLE HEAD DROP COUPLINGS MAY BE USED AT CONTRACTOR'S OPTION. IF FLEXIBLE HEAD DROP COUPLINGS ARE USED, USE THREADED FITTINGS. GASKET OR PRESSURE FIT TYPE FITTINGS NOT ACCEPTABLE. 8.DUCTILE IRON, CEMENT LINED, CLASS 52, MECHANICAL OR PUSH -ON RESTRAINED JOINTS FOR UNDERGROUND PIPE. B.FITTINGS: 1.COMPLY WITH REQUIREMENTS IN NFPA 13. 2.MINIMUM 125 PSI CLASS. 3.2 INCH AND SMALLER: 150 POUND BLACK MALLEABLE OR DUCTILE IRON, SCREWED, ANSI B16.3 AND ASTM A 197. 4.OR 1 DUCTILE IRON ASTM 5GROOVED S JOINT LLANGED FIIT'TINGS,,FORGEDOSTEEL ASTM 47 DUCTILE IRON. 5.GROOVED JOINT COUPLINGS: UL LISTED AND LABELED FOR SPRINKLER SERVICE. MALLEABLE IRON ASTM A 47 OR DUCTILE IRON ASTM A 536 HOUSING. CHLORINATED BUTYL GASKET. NUTS AND BOLTS ASTM A 183. MINIMUM 110,000 PSI TENSILE. 6.INTERNAL AND EXTERNAL GALVANIZED STEEL FITTINGS FOR EXTERIOR PIPES, DRY PIPE SPRINKLER SYSTEMS, AND DRAINS. 7.PLAIN END COUPLINGS: PLAIN END COUPLINGS (ROUST -A- BOUTS, PLAINLOKS OR SIMILAR COUPLINGS) NOT ACCEPTABLE. 8.HOLE CUT OUTLETS: a. NOT ACCEPTABLE FOR NEW SYSTEMS. 2.4 VALVES A.GENERAL: UL LISTED AND LABELED AND FM APPROVED, MINIMUM 175 PSI CLASS. 2.5 SPRINKLER HEADS A.AUTOMATIC SPRINKLER QUICK RESPONSE HEADS OF THE TYPE AS REQUIRED BY THE AHJS AND FINISH FOR THE AREAS AND CEILING CONSTRUCTION DESIGNATED IN SCHEDULE ON THE DRAWINGS. B.OPERATING TEMPERATURE: COMPLY WITH REQUIREMENTS IN NFPA 13. SELECT TO COMPENSATE FOR THE MAXIMUM TEMPERATURES WHICH OCCUR IN A PARTICULAR AREA DURING EITHER WINTER OR SUMMER CONDITIONS FROM SUCH SOURCES AS UNIT HEATERS AND SUNLIGHT. IN NO CASE USE HEADS RATED LESS THAN 50 F HIGHER THAN ANTICIPATED AMBIENT TEMPERATURE. C.INCH DEDNT CSRNLR, AUFTIG OR FRICTION FIT FOR EACH PENDANT PIKE SELF-ADJUSTING FITTING AGAINST IN D.SPRINKLER HEAD GUARDS: INCLUDE WHERE SPRINKLER HEADS ARE SUBJECT TO DAMAGE AND FOR SPRINKLER HEADS INSTALLED LOWER THAN 7 FEET ABOVE FINISHED TPERSTEER. ASNG NLPATYAFEER NAP BLE CWITH N CYFAN SPRING MAINTENANCE ACCESS WIRE A TYPE OR SCREW PLATED IN FINISHED AREAS. E.SPRINKLER CABINET: INCLUDE WITH REQUIRED NUMBER OF SPRINKLER HEADS OF RATINGS AND TYPES INSTALLED. ALSO INCLUDE ESCUTCHEONS AND SPRINKLER WRENCH. 2.7 ALARM AND SIGNAL DEVICES A.WATERFLOW SWITCH (SYSTEMS WITHOUT ALARM VALVES): VANE OR PADDLE TYPE FLOW SWITCH, INSTALLED AND CONNECTED IN SUCH A MANNER THAT FLOW OF WATER EQUAL TO OR GREATER THAN THAT FROM A SINGLE HEAD WILL AUTOMATICALLY ENERGIZE FIRE ALARM SYSTEM. INCLUDE FIELD ADJUSTABLE TIME DELAY, ADJUSTABLE FROM 0 TO 60 SECONDS. B.VALVE MONITOR SWITCHES: 115 VAC. BUILT -IN DUAL SUPERVISORY TAMPER SWITCH OR ATTACHMENT FOR FIELD INSTALLED EXTERNAL SUPERVISORY TAMPER SWITCH FOR GATE VALVES. INCLUDE FOR POST INDICATOR VALVES SHOWN ON CIVIL DRAWINGS. C.PRESSURE GAGES: 3 -112 INCH DIAL, PHOSPHOR BRONZE TUBE, BRASS SOCKET, 300 PSI RANGE. INCLUDE NEEDLE VALVE. 2.8 BUILDING FIRE ALARM SYSTEM INTERFACE A.COORDINATE WITH WORK SPECIFIED IN DIVISION 28. 2.9 SPECIALTIES A.PIPE SUPPORTS: INCLUDE METAL PIPE SUPPORTS FLEXIBLE CONNECTIONS, SWAY BRACES HANGERS, CLAMPS, AND OTHER PIPE SUPPORT ITEMS IN ACCORDANCE WITH REQUIREMENTS IN NFPA 13. SEISMICALLY DESIGN PIPE HANGERS AND BRACES PER IBC, AS EN7-05 AND SM C RETi41NING NOT USE "C- CLAMP" HANGERS UNLESS THEY B.IDENTIFICATION SIGNS: ENAMELED SIGNS FOR DRAIN VALVES, TEST VALVES, CONTROL VALVES, AND ALARM VALVES INDICATING THEIR USE. C.MISCELLANEOUS CONNECTIONS AND FITTINGS: DRAIN VALVES, INSPECTOR'S TEST CONNECTIONS, FLUSHING CONNECTIONS, DISCHARGE OUTLETS, AND OTHER ITEMS IN ACCORDANCE WITH REQUIREMENTS IN NFPA 13. D.PIPE SLEEVES: COMPLY WITH REQUIREMENTS IN SECTION 200510. E. PIPE ESCUTCHEON PLATES: COMPLY WITH REQUIREMENTS IN SECTION 202115. PART 3 - EXECUTION 3.1 INSPECTION A.GENERAL: VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK OF THIS SECTION. DO NOT INSTALL UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. 3.2 PREPARATION A.FIELD MEASUREMENTS: FIELD VERIFY LOCATIONS OF NEW AND EXISTING WORK PRIOR TO COMMENCING WORK OF THIS SECTION. B.PROTECTION: PROTECT SURROUNDING AREAS AND SURFACES TO PRECLUDE DAMAGE FROM WORK OF THIS SECTION. 3.3 INSTALLATION, APPLICATION ERECTION, AND PERFORMANCE A.GENERAL: INSTALL, APPLY, ERECT, AND PERFORM THE WORK IN ACCORDANCE WITH SPECIFICATIONS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS AND DIRECTIONS. WHERE THESE MAY BE IN CONFLICT, THE MORE STRINGENT REQUIREMENTS GOVERN. B.COOPERATE WITH OTHER TRADES TO ENSURE ADEQUATE SPACE FOR PIPING PLACEMENT. C.COORDINATEWWORK AND IMINIIMIZESIJNNECESSARY OFFSETS AND OTHER TRADES APPROVED SHOP DRAWINGS. FAILURE TO COORDINATE DOES NOT RELIEVE FIRE SUPPRESSION SUBCONTRACTOR FROM MEETING PERFORMANCE STANDARDS SPECIFIED IN THIS SECTION. 1. FIRE SUPPRESSION PIPING SHALL NOT: a.REDUCE HEADROOM TO LESS THAN 7' -0" EXCEPT ABOVE CATWALKS. b. PROJECT INTO ANY CATWALK, PASSAGEWAY LADDER RUN, ACCESS OR EGRESS. c.INTERFERE WITH ELECTRICAL EQUIPMENT 0R ACCESS TO MECHANICAL UNITS (INCLUDING FILTERS). D.RELOCATE PIPING AND SPRINKLER HEADS WHICH, IN THE OPINION OF THE A /E, DO NOT COMPLY WITH THE ABOVE IN A MANNER ACCEPTABLE TO THE A/E. E.DO NOT ORDER, FABRICATE, OR INSTALL MATERIALS UNTIL APPROVALS ARE RECEIVED FROM AHJS. F.INSTALL MATERIAL IN STRICT ACCORDANCE WITH SHOP DRAWINGS APPROVED BY THE AHJS AND REVIEWED BY THE A/E. G.SERVICE INTERRUPTIONS: OBTAIN ADVANCE APPROVAL FROM THE OWNER AND LOCAL FIRE DEPARTMENT. 3.4 FIRE SUPPRESSION SYSTEMS INSTALLATION A.INSTALL PIPING CONCEALED ABOVE FURRED CEILINGS TO MINIMIZE OBSTRUCTIONS. B.SUPPORT PIPING ONLY FROM STRUCTURAL MEMBERS AND NOT FROM WORK OF OTHER TRADES. C.INSTALL PIPING SYSTEM BRACED TO WITHSTAND DAMAGE FROM EARTHQUAKES. INSTALL FLEXIBLE COUPLINGS AND EARTHQUAKE BRACING IN ACCORDANCE WITH IBC, ASCE 7 -05, AND NFPA 13. D.INSTALL SYSTEM AND AUXILIARY DRAINS TO DISCHARGE TO PAVED AREAS CONCRETE SPLASH BLOCKS, SUITABLE WASTE WITHIN BUILDING, OR TO OTHER LOCATIONS AS INDICATED OR REQUIRED BY THE A/E. E.INSTALL BALL DRIP VALVE ON CHECK VALVE TO DRAIN PIPING FOR FIRE DEPARTMENT CONNECTION. DRAIN TO FLOOR DRAIN OR OUTSIDE BUILDING. F. ESCUTCHEON PLATES: INSTALL AT EXPOSED PIPE PENETRATIONS OF CEILINGS, FLOORS, AND WALLS. G.INSTALL HEAD GUARDS ON SPRINKLER HEADS INSTALLED LOWER THAN 7 FEET ABOVE FINISHED FLOOR GRATING, AND MAINTENANCE ACCESS AREA. INSTALL ON EXTERIOR SPRINKLER HEADS. H.INSTALL SPRINKLER CABINET ADJACENT TO ALARM VALVE ASSEMBLY. I. INSTALL INSPECTOR TEST VALVE AT HIGHEST AND MOST HYDRAULICALLY REMOTE PART OF SYSTEM IN RELATION TO RISER ASSEMBLY. LOCATE TEST VALVES TO BE ACCESSIBLE FROM FLOOR. COORDINATE LOCATIONS WITH A /E. PIPE TO STANDPIPE DRAIN OR EXTERIOR CONCRETE SPLASH BLOCK. J.INSTALL SLEEVES THROUGH WALLS AND FLOORS. COMPLY WITH REQUIREMENTS IN SECTION 200510. K.IDENTIFICATION SIGNS: INSTALL WITH CHAIN ON STEM OF VALVES. COMPLY WITH REQUIREMENTS IN NFPA 13. 3.5 FIRE DETECTION AND SYSTEM ACTUATION A.COORDINATE WITH FIRE ALARM SYSTEM WORK IN DIVISION 28. B.SWITCHES: INSTALL WATERFLOW SWITCH FOR FIRE SPRINKLER SYSTEMS. INSTALL VALVE MONITOR SWITCHES FOR VALVES, INCLUDING POST INDICATOR VALVES. 3.6 ELECTRIC POWER FOR FIRE SUPPRESSION SYSTEMS A.COORDINATE ELECTRICAL POWER SOURCE REQUIRED FOR WORK OF THIS SECTION WITH DIVISION 26. B.WHERE NOT SHOWN ON THE ELECTRICAL DRAWINGS, PROVIDE POWER WIRING FROM ELECTRICAL PANEL CIRCUIT BREAKERS TO DEVICES REQUIRING LINE VOLTAGE POWER. SIMILARLY, PROVIDE LOW VOLTAGE WIRING FROM ALARM AND SIGNAL DEVICES TO FIRE ALARM SYSTEM FOR FINAL CONNECTIONS BY THE FIRE ALARM SYSTEM SUBCONTRACTORS. C.WHERE EMERGENCY POWER IS INCLUDED IN THE WORK OR EXISTS IN BUILDING, EXTEND ELECTRICAL POWER SOURCE FROM THAT EMERGENCY POWER SYSTEM. 3.7 FIELD QUALITY CONTROL A.FLUSH, TEST, AND INSPECT FIRE SUPPRESSION AND STANDPIPE SYSTEMS ACCORDING TO NFPA 13. B.TEST COMPLETE ALARM SYSTEM, INCLUDING CONTROL AND SIGNAL CIRCUITS. C.NOTICE: GIVE 1 WEEK NOTICE AND ARRANGE FOR FIELD TESTS AND INSPECTIONS BY AHJS, INCLUDING PAYING FOR INSPECTION FEES AND SECURING PERMITS FOR SAME. D.APPROVAL AND ACCEPTANCE: AFTER FIRE SUPPRESSION SYSTEMS HAVE BEEN COMPLETELY INSTALLED, TESTED, AND SUBSTANTIAL COMPLETION REVIEW ITEMS CORRECTED, OBTAIN APPROVAL AND ACCEPTANCE OF SYSTEM BY AHJS IN ACCORDANCE WITH NFPA 13. RETESTS DUE TO FAILURE TO MEET DESIGN REQUIREMENTS SHALL BE AT NO ADDITIONAL COST TO THE OWNER. SUBMIT COMPLETED CONTRACTOR'S MATERIAL AND TEST CERTIFICATE USING FORM IN NFPA 13. 3.8 CLEANING AND PROTECTION A.CLEAN DIRT AND DEBRIS FROM SPRINKLERS. B.APPLY MASKING TAPE OR PAPER COVER TO PROTECT SPRINKLER HEADS, COVER PLATES, AND SPRINKLER ESCUTCHEONS TO PROTECT FROM FIELD PAINTING. REMOVE AFTER PAINTING. REMOVE SPRINKLER HEADS HAVING PAINT OTHER THAN FACTORY FINISH AND PROVIDE NEW. CLEANING AND REUSE OF PAINTED SPRINKLER HEADS NOT ACCEPTABLE. C.PROTECT SPRINKLER HEADS FROM DAMAGE UNTIL SUBSTANTIAL COMPLETION. D.FIRE SUPPRESSION SYSTEM SUBCONTRACTOR SHALL BE RESPONSIBLE DURING INSTALLATION AND TESTING PERIODS OF SPRINKLER SYSTEMS FOR ANY DAMAGE TO WORK OF OTHERS AND TO BUILDING AND ITS CONTENTS CAUSED BY LEAKS IN EQUIPMENT, BY UNPLUGGED OR DISCONNECTED PIPES FITTINGS OR BY OVERFLOW, AND SHALL PAY FOR NECESSARY REPLACEMENTS OR REPAIRS TO WORK OF OTHERS DAMAGED BY SUCH LEAKAGE. END OF SECTION REVIEWED FOR CODE COMPLIANCE AramiWE DEC 10 2111U City of Tukwila BUILDINGDIVISInh' ECEIVED OCT 13 2010 PERMIT CENTER V U MECHANICAL SPECIFICATIONS o REVISIONS TECTURE c; NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 JMR RKE 9 -10 -2010 O.4 rn Z J Et I Q % 12 0 (n M o O_ 7 co o CO 0 2 ro ai w� o wa ~ W C1 O J L DIVISION 22 SECTION 221116 - DOMESTIC WATER SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES DOMESTIC WATER PIPING FOR POTABLE AND NON - POTABLE SYSTEMS AND ASSOCIATED APPURTENANCES. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY AND STATE CODES AND ORDINANCES. 1.3 SUBMITTALS A.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH ITEM SPECIFIED IN THIS SECTION. B.CERTIFICATES: 1. CERTIFICATES OF INSPECTION BY AUTHORITIES HAVING JURISDICTION (AHJ) 2.CERTIFICATES OF SATISFACTORY BACTERIOLOGICAL TEST C.TESTING REPORTS: PRESSURE TESTING RECORDS. PART 2 - PRODUCTS 2.1 GENERAL A.BASIC PIPING MATERIALS AND PRODUCTS REQUIRED FOR WORK OF THIS SECTION ARE SPECIFIED IN SECTIONS 200510, 200523, 202110, AND 202115. 2.2 POTABLE WATER PIPING A.ALL SIZES INSIDE BUILDING: COMPLY WITH REQUIREMENTS IN SECTION 202110. COPPER TUBING PART ON3LY_ SWEAT, FLA ITNGED, OR GROOVED JOINT CONNECTIONS ONLY. 3.1 INSPECTION A.GENERAL: VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK OF THIS SECTION. DO NOT INSTALL UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. 3.2 PIPING INSTALLATION A.COMPLY WITH REQUIREMENTS IN SECTION 202110. B.INSTALL PIPE SUPPORTS IN ACCORDANCE WITH MSS SP -69 AND SECTION 202115, WHICHEVER IS MORE STRINGENT. C.INSTALL HOT AND COLD WATER PIPING RUNOUTS TO FIXTURES OF SIZES INDICATED, BUT IN NO CASE SMALLER THAN REQUIRED BY APPLICABLE PLUMBING CODE. D.INSTALL ISOLATION VALVES AS INDICATED. 3.3 MECHANICAL EQUIPMENT CONNECTIONS A.CONNECT HOT AND COLD WATER PIPING TO MECHANICAL EQUIPMENT AS INDICATED ON THE DRAWINGS. COMPLY WITH EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. INSTALL SHUTOFF VALVE AND UNION FOR EACH CONNECTION AND DRAIN VALVE ON DRAIN CONNECTION. LOCATE UNIONS TO ALLOW REMOVAL OF EQUIPMENT WITHOUT PIPING DISASSEMBLY BEYOND UNION. 3.4 PRESSURE TESTING A.TEST PIPING AT FULL WORKING PRESSURE IN ACCORDANCE WITH APPLICABLE PLUMBING CODE. COMPLY WITH REQUIREMENTS IN SECTION 202110. INCLUDE TEST RESULTS IN OPERATION AND MAINTENANCE MANUALS. 3.5 STERILIZATION AND FLUSHING OF WATER PIPING A.AFTER COMPLETION OF WATER PIPING INSTALLATION, BUT PRIOR TO CONNECTION TO EXISTING MAINS, FLUSH SYSTEM WITH CLEAN WATER. COMPLY WITH REQUIREMENTS IN SECTION 202110. TAKE SAMPLE OF WATER FROM SYSTEM TO DETERMINE COMPLIANCE WITH HEALTH DEPARTMENT STANDARDS. OBTAIN NECESSARY TESTS FROM GOVERNING HEALTH DEPARTMENT. IF SAMPLE IS B.STTERILIZEFFOR I EIGHT PERFORM CONTACT TIME WITH 50 PARTS PER MILLION CHLORINE CONCENTRATION. OPEN VALVES SEVERAL TIMES. FOLLOW BY FLUSHING WITH CLEAN WATER UNTIL RESIDUAL CHLORINE IS LESS THAN 0.2 PARTS PER MILLION. C.AFTER FLUSHING AND STERILIZATION ARE COMPLETE CONDUCT TESTS TO DETERMINE COMPLIANCE WITH HEALTH DEPARTMENT STANDARDS FOR STERILIZATION RESULTS. IF PIPE SYSTEM IS FOUND TO BE CONTAMINATED CORRECT DEFECTS AND PERFORM ADDITIONAL FLUSHING AND STERILIZATION UNTIL SATISFACTORY RESULTS ARE OBTAINED. D.SUBMIT WRITTEN CERTIFICATION OF FLUSHING AND STERILIZATION BY LOCAL AHJ. END OF SECTION SECTION 221316 - SOIL, WASTE, AND VENT PIPING SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES BUILDING DRAINAGE PIPING AND ASSOCIATED APPURTENANCES. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY AND STATE CODES AND ORDINANCES. 1.3 SUBMITTALS A.SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA, ASSEMBLY -TYPE SHOP DRAWINGS, AND MAINTENANCE DATA. B.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH ITEM SPECIFIED IN THIS SECTION. C.TEST REPORTS: 1. FIELD START -UP AND TEST REPORTS. 2.SUBMIT COMPLETED COPY OF REPORT AND INCLUDE COPY IN THE OPERATION AND MAINTENANCE MANUAL PART 2 - PRODUCTS 2.1 GENERAL A.BASIC PIPING MATERIALS AND PRODUCTS REQUIRED FOR WORK OF THIS SECTION ARE SPECIFIED IN SECTIONS 200515 AND 202115. B.PIPING SPECIFIED IN THIS SECTION APPLY TO THE FOLLOWING SYSTEMS: 1. WASTE AND VENT. 2.INDIRECT DRAIN FOR EQUIPMENT, AIR VENT, COOLING COIL CONDENSATE DRAINS AND SIMILAR APPLICATIONS. 2.2 MANUFACTURERS A.DRAINS CLEANOUTS, AND MISCELLANEOUS: JAY R. SMITH JOSAM, WADE, ZURN, WATTS DRAINAGE, OR APPROVED. JAY R. SMITH MODEL NUMBERS ARE LISTED. 2.3 PIPING, TUBING AND FITTINGS A.PIPING MATERIALS: 1. CAST IRON: a.PIPE: SERVICE WEIGHT CAST IRON SOIL PIPE MARKED WITH COLLECTIVE TRADEMARK OF CAST CISPI IRON SOIL PIP E INSTITUTE (CISPI). b.HUB AND SPIGOT JOINTS: ASTM A 74 COMPRESSION GASKETED TYPE SPECIFICALLY DESIGNED FOR PIPE AND FITTINGS USED OR CAULKED TYPE. GASKETS ASTM C 564, RUBBER. c. HUBLESS JOINTS: ASTM A 888 OR CISPI NO. 301 AND CISPI NO. 310. 1)COUPUNGS FOR UNDERGROUND PIPE AND FITTINGS: COMPLIANT WITH FACTORY MUTUAL RESEARCH STANDARD FM 1680, TYPE 304 STAINLESS STEEL HOUSING OR SHIELD AND STAINLESS K I SS STEEL CLAMPS, NEOPRENE GASKET WITH SEALING RINGS TO ASTM C 564. CLAMP -ALL HI TORQUE 80 OR HUSKY SD 4000. NO SUBSTITUTIONS. 2)COUPUNGS FOR ABOVE- GROUND PIPE AND FITTINGS: COMPLIANT WITH FACTORY MUTUAL RESEARCH STANDARD FM R 1680 TYPE 304 STAINLES S ST EEL HOUSING OR SHIELD AND STAINLESS STEEL CLAMPS NEOPRENE GASKET WITH SEALING RINGS TO ASTM C 564. CLAMP -ALL HI TORQUE 80 HUSKY SD 2000, OR MISSION RUBBER COMPANY HEAVYWEIGHT COUPLING. NO SUBSTITUTIONS. d.FITTINGS: ASTM A 74 FOR HUB AND SPIGOT PIPING AND ASTM A 888 OR CISPI 301 FOR HUBLESS PIPING. 2.GALVANIZED STEEL: a.PIPE: STANDARD WEIGHT OR SCHEDULE 40, ASTM A 53 OR ASTM A 106. b. FITTINGS: c.DRAINAGE FITTINGS: GALVANIZED CAST IRON DRAINAGE PATTERN, SCREWED ASME B16.12. d. VENT FITTINGS: 150 POUND GALVANIZED MALLEABLE IRON, SCREWED, ASME B16.3. 3.COPPER: b.FIITTINGS TYPE OPPER,DASME DRAINAGE TUBING, WROUGHTCOPPER,6ASME B16.29, SOLDER JOINT. B.ABOVE- GROUND WASTE AND VENT PIPING: 1.1-1/2 INCH AND SMALLER: CAST IRON, OR COPPER AT CONTRACTORS OPTION. 2.2 INCH AND LARGER: CAST IRON. C.INDIRECT DRAIN (CONDENSATE) PIPING: COPPER. 2.4 CLEANOUTS A.STANDARD: FABRICATE IN ACCORDANCE WITH ASME A 112.36.2M. B.FLOOR CLEANOUTS (FCO_,) IN FINISHED SPACES: COATED CAST IRON BODY AND FRAME, ROUND ADJUSTABLE WHERNNECINSTALBLEOD IN TOP, TAPER WTHTCARPDE,T.BRVERIFYPFLOOR (FINISH WIITH ROOM FINISH SCHEDULE ON THE ARCHITECTURAL DRAWINGS. JAY R. SMITH FIGURE 4023S. C.ADJUSTABLLEENSCORIATED )CASTLIRONITOPDWITHCNON -TITLT HEAVY DUN IRON APER THRE'ADROUND BRONZE PLUG. JAY R.) SMITH FIGURES 4243S OR 4253S. D.COVERCANDNVANDAL W PTR)OOFCS CAST LENGTH OF WITH TAPER TO SUITAIINSTTAOLLATION STAINLESS STEEL JAY R. SMITH FIGURE 4472T. 2.5 VENTS THROUGH ROOF A.VENT FLASHINGS: 1. DEKTITE FLASHINGS (FLEXIBLE RUBBER BOOT FLASHING) AT PIPE PENETRATIONS THROUGH STEEL OR COMPOSITION ROOFS. 2.USE 4 POUND PER SQUARE FOOT SEAMLESS LEAD FLASHING SKIRT MINIMUM OF 8 INCHES EXTENDING FROM PIPE WITH CONICAL GALVANIZED STEEL REINFORCING BOOT AND TT COUNTERFLASHING FITTING ON BUILT -UP ROOFING. B.CONNEIN TRECTAPPESTHREAED NELR STEL PPEPTCEESD SECTO FOR PIPES, BASFOE ISWIH RECESSED T SCREW. JAY R. SMITH FIGURE 1748. PART 3 - EXECUTION 3.1 PIPING INSTALLATION A.GENERAL: 1. COMPLY WITH REQUIREMENTS IN SECTION 202110. 2.INSTALL WITH UNIFORM PITCH OF AT LEAST 1/4 INCH PER FOOT FOR HORIZONTAL WASTE AND RAINLEADER PIPING, UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR ALLOWED BY AHJ. 3.INSTALL CAST IRON SOIL PIPING ACCORDING TO CISPI'S "CAST IRON SOIL PIPE AND FITTINGS HANDBOOK ", 4.PITCH VENTS FOR PROPER DRAINAGE. VENT PIPING MAY BE INSTALLED HORIZONTAL IF REQUIRED TO AVOID CONFLICT WITH BUILDING ELEMENTS. 5.JOINTS AND CONNECTIONS: *.BELL AND SPIGOT: NEOPRENE COMPRESSION SEALS. b.HUBLESS: ALTERNATELY AND INCREMENTALLY TIGHTEN CLAMP BOLTS TO MANUFACTURER'S RECOMMENDED TORQUE VALUE, USING SINGLE SETPOINT TORQUE WRENCH SPECIFICALLY MANUFACTURED FOR THIS PURPOSE. DO NOT USE SCREWDRIVERS OR OTHER TYPES OF WRENCHES. RETORQUE AFTER 24 HOURS IF REQUIRED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS. 6.CLEAN INTERIOR OF PIPING OF DIRT AND OTHER SUPERFLUOUS MATERIAL AS WORK PROGRESSES. MAINTAIN SWAB IN PIPING AND PULL PAST EACH JOINT AS COMPLETED. 7.PLACE PLUGS IN ENDS OF UNCOMPLETED PIPING AT END OF DAY OR WHENEVER WORK STOPS. B.ABOVE- GROUND PIPING: 1. SUPPORT HORIZONTAL PIPING TO MAINTAIN ALIGNMENT, PREVENT GRADE REVERSALS, AND PREVENT SAGGING. 2.SUPPORT VERTICAL STACKS AT EACH FLOOR WITH RISER CLAMPS. 3.HUB AND SPIGOT PIPE: SUPPORT AT 5 FEET MAXIMUM CENTERS AND WITHIN 18 INCH OF EACH JOINT. MINIMUM 1 HANGER OR SUPPORT BETWEEN ANY 2 JOINTS AND FITTINGS. 4.HUBLESS PIPE: PROVIDE HANGERS AND SUPPORTS IN ACCORDANCE WITH APPLICABLE PLUMBING CODE. C.UNDERGROUND PIPING: 1. PERFORM TRENCHING AND BACKFILLING ASSOCIATED WITH PLUMBING INSTALLATION IN ACCORDANCE WITH PERTINENT PROVISIONS OF EXCAVATING, FILLING, AND GRADING REQUIREMENTS IN DIVISION 31 AND SECTION 200515. 2.UNIFORM SUPPORT AND SPIGOT IPIPE,PANDGTO INSTALL JOINING. IN INSTALL HUBS GRADED PROVIDE 3.2 CLEANOUTS A.INSTALL WASTE, CLEANOUTS AT BASE OF STACKS AND IN ACCORDANCE WITH REQUIREMENTS IN THE APPLICABLE PLUMBING CODE. FULL PIPE SIZE, 4 INCH MAXIMUM. LOCATE AT MINIMUM 50 FOOT INTERVALS FOR PIPING 4 INCH AND SMALLER AND AT 100 FOOT INTERVALS FOR PIPING 6 INCH AND LARGER. B.INSTALL WALL CLEANOUTS IN RESTROOMS WITH GREATER THAN 2 WATER CLOSETS AND URINALS OR AS INDICATED ON PLANS. C.INSTALL AT SINKS. D.DEMONSTRATE REMOVAL OF CLEANOUT COVERS. 3.3 VENTS THROUGH ROOF A.LOCATIONS SHOWN ON THE DRAWINGS ARE PRELIMINARY. COORDINATE FINAL LOCATIONS WITH OTHER TRADES, MINIMUM 10' -0" FROM OUTSIDE AIR INTAKES. B.ROOF PENETRATIONS SHALL BE BY LANDLORD'S ROOF CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. 3.4 EQUIPMENT CONNECTIONS A.INSTALL SOIL AND WASTE PIPING RUNOUTS TO PLUMBING FIXTURES AND DRAINS WITH APPROVED TRAP AND SIZES INDICATED ON THE DRAWINGS, BUT IN NO CASE SMALLER THAN THAT REQUIRED BY THE APPLICABLE PLUMBING CODE. B.LOCATE PIPING RUNOUTS AS CLOSE AS POSSIBLE TO BOTTOM OF FLOOR SLAB SUPPORTING FIXTURES AND DRAINS. C.INSTALL TRAP WHERE MANUFACTURER DOES NOT INCLUDE TRAP FOR FIXTURE. INSTALL TO BE REMOVABLE FOR SERVICING AND REPLACEMENT. D.INSTALL DRAIN FLASHING COLLAR OR FLANGE SO THAT NO LEAKAGE OCCURS BETWEEN DRAIN AND ADJOINING FLOORING. MAINTAIN INTEGRITY OF WATERPROOF MEMBRANES. E.INSTALL CONDENSATE DRAINS FROM COOLING COIL CONDENSATE DRAINS WITH TRAP. TERMINATE WITH 1 INCH AIR GAP OVER FLOOR DRAIN, FLOOR SINK, SERVICE SINK, OUTDOORS, OR AS INDICATED ON THE DRAWINGS. 3.5 PRESSURE TESTING A.TEST DRAINAGE PIPING IN ACCORDANCE WITH APPLICABLE PLUMBING CODE. COMPLY WITH REQUIREMENTS IN SECTION 202110. TEST BY AIR OR WATER FOR METAL PIPING AND BY AIR FOR ABS PIPING. INCLUDE TEST RESULTS IN OPERATION AND MAINTENANCE MANUALS. END OF SECTION SECTION 224000 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES PLUMBING FIXTURES AND FITTINGS INSTALLATIONS OF AND CONNECTIONS TO FIXTURES FURNISHED UNDER OTHER SPECIFICATION DIVISIONS AND ASSOCIATED APPURTENANCES. B.GENERAL REQUIREMENTS. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY AND STATE CODES AND ORDINANCES. B.CODES AND STANDARDS: 1.ICC A117.1, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES. 2.PUBLIC LAW 102 -486 ENERGY POLICY ACT. 3.NSF 61, DRINKING WATER SYSTEM COMPONENTS HEALTH EFFECTS. .SELECT COMBINATIONS OF FIXTURES AND TRIM, FAUCETS, FITTINGS, AND OTHER COMPONENTS THAT ARE COMPATIBLE. D.FIXTURES SHALL BE VANDAL RESISTANT. 1.3 SUBMITTALS A.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH ITEM SPECIFIED IN THIS SECTION. INDICATE ACCESSORIES WHERE REQUIRED FOR COMPLETE SYSTEM AND INSTALLATION INSTRUCTIONS. 1.4 DEFINITIONS A.ACCESSIBLE FIXTURE: PLUMBING FIXTURE THAT CAN BE APPROACHED, ENTERED, AND USED BY PEOPLE WITH DISABILITIES. B.FITTINGS AND TRIM: DEVICES THAT CONTROL FLOW OF WATER INTO OR OUT OF PLUMBING FIXTURE. FITTINGS SPECIFIED IN THIS SECTION INCLUDE SUPPLIES AND STOPS FAUCETS AND SPOUTS, SHOWER HEADS, DRAINS AND TAILPIECES, AND TRAPS AND WASTE PIPES. 1.5 COORDINATION ' A.COORDINATE ROUGHING -IN AND FINAL PLUMBING FIXTURE LOCATIONS AND VERIFY THAT FIXTURES CAN BE INSTALLED TO COMPLY WITH ORIGINAL DESIGN AND REFERENCED STANDARDS. PART 2 - PRODUCTS 2.1 MANUFACTURERS A.STAINLESS STEEL SINKS: ELKAY JUST OR APPROVED. B.FAUCETS: CHICAGO FAUCETS 0R APPROVED. C.PLUMBING BRASS: AMERICAN STANDARD BRASSCRAFT, KOHLER, CHICAGO FAUCET, CRANE, EWER, SPEAKMAN, SYMMONS T &S BRASS MCGUIRE ELKAY, JUST OR APPROVED. 2.2 PLUMBING FIXTURES AND TRIM GENERAL ' ERAL A.FIXTURE: AS SCHEDULED IN PLUMBING FIXTURE SCHEDULE ON PLANS. B.FIXTURE COLOR: WHITE UNLESS OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS. C.EXPOSED METAL PARTS: CHROMIUM OVER NICKEL FINISH. D. NTFEGRALL VALVES: INCLUDE IN WATER AANGLEF CONNECTIONS WITH LOCK TSHIELD EXCEPT VERTICAL TUBE, POLISHED CHROME PLATE FINISH WHERE EXPOSED AND ROUGH WHERE CONCEALED. E.EXPOSED SUPPLIES: 1/2 INCH OUTSIDE DIAMETER ANNEALED VERTICAL TUBING. F. PIPE ESCUTCHEONS: INCLUDE WHERE PIPE OR OTHER FITTING ENTERS WALL AT FIXTURE. COMPLY WITH REQUIREMENTS IN SECTION 202115. G.TAILPIECE EXTENSION, TRAP, AND ARM TO WALL: 17 GAGE, SEAMLESS, CHROME PLATED TUBING WITH CLEANOUT FOR SINKS. H.VACUUM BREAKER: INCLUDE ON WATER SUPPLY TO EACH FIXTURE WHICH HAS A WATER CONNECTION LOCATED BELOW THE RIM AND FOR FIXTURES WITH FAUCETS WITH THREADED OUTLETS FOR HOSE ATTACHMENT, FLOW- THROUGH PATTERN. 2.3 SEALANT A.MANUFACTURER AND TYPE: COLOR TO MATCH FIXTURE. GENERAL ELECTRIC NO. 1200 SILICONE PART UIILDING SEEAXLEAC I,fION W CORNING NO. 780 CONSTRUCTION SEALANT, OR APPROVED. 3.1 FIXTURE INSTALLATION FITTINGS, AND OTHER COMPONENTS ACCORDING TO MANUFACTURERS' A.ASSEMBLE FIXTURES TRIM NGS D E COM 0 ENTS WRITTEN INSTRUCTIONS. REFER TO 'ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS. B.COUNTER - MOUNTED FIXTURES: INSTALL AND ATTACH TO CASEWORK. C.INSTALL WATER- SUPPLY PIPING WITH STOP ON EACH SUPPLY TO EACH FIXTURE TO BE CONNECTED TO WATER DISTRIBUTION PIPING. ATTACH SUPPLIES TO SUPPORTS OR SUBSTRATE WITHIN PIPE SPACES BEHIND FIXTURES. D.FOR FIXTURES WITHOUT INTEGRAL TRAPS INSTALL TRAP AND WASTE PIPING ON DRAIN OUTLET OF EACH FIXTURE TO BE DIRECTLY CONNECTED TO SANITARY DRAINAGE SYSTEM. E.INSTALL WATER HAMMER ARRESTERS IN ACCORDANCE WITH PLUMBING DRAINAGE INSTITUTE STANDARD P.D.I. WH -201 OR ASSE 1010 RECOMMENDATIONS. INSTALL AT ENDS OF HOT AND SERVING 2 OR MORE FIXTURES AND AT SOLENOID VALVES, DISHWASHERS, AND COLD WATER PIPES SERV A , OTHER EQUIPMENT HAVING QUICK CLOSING VALVES. 3.2 PLUMBING FIXTURES, FITTINGS AND TRIM CONNECTION A.CONNECT HOT AND COLD WATER AND SOIL, WASTE, AND VENT PIPING TO PLUMBING FIXTURES AS INDICATED ON THE DRAWINGS. COMPLY WITH EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3.3 FIELD QUALITY CONTROL A.REPLACE DAMAGED FIXTURES AND COMPONENTS. B.TEST INSTALLED FIXTURES AFTER WATER SYSTEMS ARE PRESSURIZED FOR PROPER OPERATION. 3.4 ADJUSTING A.OPERATE AND ADJUST FAUCETS AND CONTROLS. B.ADJUST WATER PRESSURE AT FAUCETS AND FLUSH VALVES TO PRODUCE PROPER FLOW AND STREAM. C.REPLACE WASHERS AND SEALS OF LEAKING AND DRIPPING FAUCETS AND STOPS. D.TEST AND BALANCE TRAP PRIMER SYSTEMS. ARRANGE PIPING TO ACHIEVE EQUAL FLOW TO EACH FLOOR DRAIN AND FLOOR SINK. 3.5 CLEANING A.CLEAN F1 FIXTURES, SKATE FAUCETS, AND OTHER FITTINGS WITH MANUFACTURERS' RECOMMENDED CLEANING END OF SECTION SECTION 226313 - MEDICAL GAS PIPING SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES MEDICAL GAS PIPING SYSTEMS AND ASSOCIATED APPURTENANCES AS EXTENSION OF EXISTING SYSTEMS. B.GENERAL REQUIREMENTS: DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS, DIVISION 01, AND SECTIONS 200500 AND 200510 APPLY TO WORK IN THIS SECTION. 1.2 QUAUTY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY, AND STATE CODES AND ORDINANCES. B.CODES AND STANDARDS: 1.AMERICAN INSTITUTE OF CARCHITE TS, GUIDELINES FOR CONSTRUCTION AND EQUIPMENT OF 2.ASME BPVC, BOILER PRESSURE AND VESSEL CODE, SECTION VIII, RULES FOR CONSTRUCTION OF PRESSURE VESSELS DIVISION 1. 3.ASSE 6000 SERIES PROFESSIONAL QUALIFICATIONS STANDARD FOR MEDICAL GAS SYSTEMS INSTALLERS, INSPECTORS, VERIFIERS, MAINTENANCE PERSONNEL AND INSTRUCTORS. 4.COMPRESSED GAS ASSOCIATION (CGA): a.PAMPHLET G -4.1, CLEANING EQUIPMENT FOR OXYGEN SERVICE. b.PAMPHLET G -6.1, STANDARD FOR NITROUS OXIDE SYSTEMS AT CONSUMER SITES. c.PAMPHLET M -10, GUIDE FOR MEDICAL GAS SUPPLY SYSTEMS AT CONSUMER SITES. d.PAMPHLET P -1, SAFE HANDUNG OF COMPRESSED GASES IN CONTAINERS. e.PAMPHLET P -2, CHARACTERISTICS AND SAFE HANDLING OF MEDICAL GASES. f. PAMPHLET V -5, DIAMETER INDEX SAFETY SYSTEMS (DISS). S.CRYOGEN'ISTANDARD FLUIDS DINE FOR AND STATIONARY CONTAINERS, CYLINDERS, COMPRESSED GASES AND 6.NFPA 70, NATIONAL ELECTRICAL CODE. 7.NFPA 99, STANDARDS FOR HEALTH CARE FACILITIES. 8.UNITED STATES PHARMACOPOEIAL CONVENTION (USP), UNITED STATES PHARMACOPOEIA XXVIII/ NATIONAL FORMULARY XXIII. 9.WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 246 -320. C.MEDICAL GAS EQUIPMENT MANUFACTURER'S (MGEM) QUALIFICATIONS: 1.PERSONNEL ASSEMBUNG MEDICAL AIR, VACUUM, AND WASTE ANESTHETIC GAS DISPOSAL (WAGD) PLANT SHALL MEET NFPA 99 AND HOLD MEDICAL GAS ENDORSEMENTS REQUIRED BY ASSE 60110. 2.ONE MGEM SHALL SUPPLY MEDICAL GAS SYSTEMS AND EQUIPMENT INCLUDING OUTLETS AND VALVES. D.MEDICAL GAS PIPING INSTALLER'S QUALIFICATIONS: QUALIFY INSTALLERS ACCORDING TO ASSE 6010. E.TESTING AGENCY QUALIFICATIONS: 1.DEMONSTRATE TO A /E'S SATISFACTION, BASED ON A /E'S EVALUATION OF CRITERIA CONFORMING TO ASTM E699 THAT INDEPENDENT TESTING AGENCY HAS THE EXPERIENCE AND CAPABILITY TO SATISFACTORILY CONDUCT TESTING INDICATED WITHOUT DELAYING THE WORK. 1.3 SUBMITTALS A.COMPLY WITH REQUIREMENTS IN DIVISION 01 AND SECTION 200500. B.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR THE FOLLOWING: 1. PIPING MATERIALS. 2.MEDICAL GAS OUTLETS. 3.PIPING SPECIALTIES. C.COMPLIANCE AFFIDAVIT: SUBMIT THAT MEDICAL GAS EQUIPMENT MANUFACTURER ATTESTS COMPLIANCE WITH RELEVANT PARAGRAPHS OF NFPA 99. D.QUAUFICATIONS: 1. SUBMIT DOCUMENTATION AS DEFINED UNDER PARAGRAPH ()MEDICAL GAS EQUIPMENT MANUFACTURER'S QUALIFICATIONS.* 2.SUBMIT DOCUMENTATION AS DEFINED UNDER PARAGRAPH °MEDICAL GAS PIPING INSTALLER'S QUALIFICATIONS.° 3.SUBMIT DOCUMENTATION FOR INDEPENDENT TESTING AGENCY. E.TESTING REPORTS: 1. PRESSURE TESTING RECORDS. 2.CROSS- CONNECTION TESTS. 3.PURGE AND ANALYSIS TESTS. 4.ALARM TESTS. 5.INCLUDE COPY OF REPORTS IN THE OPERATION AND MAINTENANCE MANUAL. F. CERTIFICATIONS: SUBMIT DOCUMENTATION AS DEFINED UNDER ARTICLE °CERTIFICATION OF SYSTEMS°. 1.4 DEFINITIONS A.BREATHING GAS: GAS TESTED TO BE PURE AND CONTAIN FEWER CONTAMINATES AS OUTLINED IN THE FOLLOWING STANDARDS: 1.OXYGEN: CGA, GRADE D. 2.USP: UNITED STATES PHARMACOPEIA /NATIONAL FORMULARY STANDARDS. 1.5 DELIVERY, STORAGE, AND HANDLING A.DELIVER AND STORE LARGE MEDICAL GAS SPECIALTIES ON FACTORY - INSTALLED SHIPPING SKIDS, SMALL SPECIALTIES IN FACTORY - FABRICATED FIBERBOARD CONTAINERS, AND PIPING WITH SEALING PLUGS IN ENDS OR WITH OTHER END PROTECTION. 1. STORE PRECLEANED AND SEALED MEDICAL GAS PIPE, FITTINGS, VALVES, AND SPECIALTIES WITH SEAUNG PLUGS AND SEALING PACKAGING INTACT. 2.LABEL MEDICAL GAS PIPE FITTINGS, VALVES AND SPECIALTIES THAT HAVE NOT BEEN PRECLEANED, OR THAT HAVE BEEN PRECLEANED BUT HAVE SEALS OR PACKAGING THAT IS NOT INTACT, WITH TEMPORARY LABELS INDICATING THAT CLEANING IS REQUIRED BEFORE INSTALLATION. 1.6 WARRANTY A.GENERAL: WARRANT MEDICAL GAS PIPELINE COMPONENTS FOR 2 YEARS AFTER FINAL ACCEPTANCE. WARRANTY SHALL COVER PARTS, LABOR AND TRAVEL TIME. MAKE AVAILABLE REPLACEMENT WITHIN 48 HOURS OF INITIAL NOTIFICATION. PART 2 - PRODUCTS 2.1 MANUFACTURERS A.MANUFACTURERS: CHEMTRON (ALLIED). NO SUBSTITUTIONS. 2.2 PIPING MATERIALS A.PRESSURIZED MEDICAL GAS PIPING: 1. ASTM B 819, TYPE L HARD DRAWN SEAMLESS MEDICAL GAS COPPER TUBING. TYPE K FOR OPERATING PRESSURE GREATER THAN 185 PSIG FOR SIZES LARGER THAN 3-1/80. IDENTIFY BY THE MARKINGS ()OXYa aMED* ()OXY /MED* aOXY /ACRa, OR °ACR /MED* IN BLUE FOR TYPE L AND GREEN FOR TYPE K. 2.FITTINGS WROUGHT COPPER, BRASS OR BRONZE DESIGNED FOR BRAZED CONNECTION. 3.PIPE, FITTINGS VALVES, AND OTHER COMPONENTS SPECIALLY CLEANED FOR OXYGEN SERVICE IN RECEIVVEEDEON JOB TO CLEANED AND CAPPED IN MATERIAL PACKAGE BEARING MANUFACTURERS AND IDENTIFICATION TAG OR STAMP. ON -SITE CLEANING OF INTERIOR SURFACES OF PIPES, VALVES, FITTINGS, AND OTHER COMPONENTS NOT ACCEPTABLE. 4.LISTED OR APPROVED FITTINGS MAY BE USED AT LIMITED EXPOSED AND ACCESSIBLE LOCATIONS IN COMPUANCE WITH NFPA 99. B.VACUUM PIPING: 1.TYPE L HARD DRAWN SEAMLESS COPPER TUBING OR ASTM B 280 ACR COPPER. 2.BRAZED WITH BCUP -5 OR ALLOY WITH AT LEAST 1000 F MELTING POINT. C.BRAZING ALLOY AWS A5.8, BCUP -5 OR APPROVED ALLOY WITH AT LEAST 1000 F MELTING POINT. D.GASKET MATERIAL: ASME B16.21, NONMETALLIC, FLAT, ASBESTOS FREE, AND SUITABLE FOR MEDICAL GAS PIPING USE. 2.3 MEDICAL GAS OUTLETS A.MANUFACTURER. CHEMETRON 400 SERIES. NO SUBSTITIONS. B.MEDICAL GAS OUTLET MODULAR, QUICK - DISCONNECT RECESSED TYPE OR DISS SCREW THREAD RECESSED TYPE. INCLUDE KEYING SYSTEM COMPATIBLE WITH EXISTING KEYING SYSTEM IN FACILITY. THREADED DISS CONNECTOR PER CGA STANDARDS. C.OUTLETS FIELD ASSEMBLED WITH SEQUENCES AND SERVICES INDICATED. D.OUTLET STATIONS WITH STAINLESS STEEL COVER PLATE. INCLUDE INDEXING PINS FOR SAFETY KEYING AND GAS SPECIFIC TO COVER ROUGH-IN THE ROUGH IN BOX WITH COLOR CODED GAS SERVICE IDENTIFICATION. SAFETY KEYING INDEX PINS PERMANENTLY CAPTURED BETWEEN COVER PLATE AND LATCH ASSEMBLY AND UNREMOVABLE WITHOUT DESTROYING OUTLET. E.THE LATCH MECHANISMS DESIGNED FOR ONE HANDED, SINGLE THRUST MOUNTING, AND 1 HANDED FINGERTIP RELEASE OF SECONDARY EQUIPMENT. F. CE TIIFIED. MEDICAL CLEANED, AND PACKAGED FOR OXYGEN SERVICE AND CGA PAMPHNLDET G-4.1. ASSEMBLY CAPPED AND FINISH ASSEMBLY POLY BAGGED FOR SHIPMENT. G.ROUGH -IN ASSEMBLY MODULAR DESIGN AND INCLUDED C DED GAS SPECIFIC 16 GAGE STEEL MOUNTING PLATE DESIGNED TO PERMIT ON -SITE GANGING OF MULTIPLE OUTLETS. INCLUDE ��M��ACHINED BRASS 'TYPE OUTLET COPPER INLET TO SWIVEL ATTACHED TO MOUNTING ATTACHMENT TO PIPING THE 1/2 1 -IN ASSEMBLY WITH DOUBLE SEAL TO PREVENT GAS LEAKAGE BETWEEN ROUGH -IN AND LATCH -VALVE ASSEMBUES AFTER WALL IS FINISHED. SINGLE 0 -RING SEAL NOT ACCEPTABLE. H.LATCH -VALVE ASSEMBLY SHALL TELESCOPE UP TO 3/4 INCH TO ALLOW FOR VARIATION IN FINISHED WALL THICKNESS FROM 1/2 INCH TO 1-1/4 INCH. I. DISS OUTLETS USED FOR CEILING MOUNT APPLICATIONS. J.INCLUDE HOSE ASSEMBLIES FOR CEILING OUTLETS FOR FINISHED CEILING HEIGHT AS INDICATED ON THE DRAWINGS. EACH HOSE WITH CHAIN TYPE DUAL RETRACTOR FOR PRESSURE GASES AND TRIPLE FOR VACUUM. RETRACTORS MADE WITH STAINLESS CABLE NOT ACCEPTABLE. INCLUDE 18 INCH HOSE LENGTH FOR REFRACTORS. 2.4 MEDICAL GAS VALVES AND VALVE ASSEMBLIES A.MEDICAL GAS VALVES SPECIALLY PREPARED FOR OXYGEN SERVICE. CONFORM TO NFPA 99. VALVES BALL TYPE WITH TEFLON SEATS AND ADJUSTING STEM PACKING GLAND WITH TEFLON STEM B.BALL VALVES 3 PIECE BODY, FULL PORT CHROME PLATED BRASS BALL BLOWOUT PROOF STEM BRAZE -JOINT ENDS, RATED 600 PSIG WOG BRASS OR BRONZE, ACTUATE FROM FULL °OPEN+) TO FULL °CLOSED° BY 90 DEGREE TURN OF VINYL GRIPPED VALVE LEVER HANDLE. C.VALVES WITH FACTORY INSTALLED TYPE K COPPER TUBING TUB NG EXTENSIONS. D.VALVES NOT IN VALVE BOXES WITH LOCKING HANDLES. E. VALVES CLEANED FOR OXYGEN, CAPPED, AND SEALED IN A POLYETHYLENE BAG FOR SHIPPING AND STORAGE. F.INCLUDE COLOR CODED SELF - ADHESIVE GAS LABELS FOR COMPLIANCE WITH NFPA 99 LABELING REQUIREMENTS. 2.5 PIPING SPECIALTIES A.PIPE MARKERS AND COLOR BANDS: COMPLY WITH REQUIREMENTS IN SECTION 200510 AND NFPA 99. B.PIPE SLEEVES: COMPLY WITH REQUIREMENTS IN SECTION 200510. C.HANGERS AND SUPPORTS: COMPLY WITH REQUIREMENTS IN SECTION 202115. D.PIPE ESCUTCHEONS: COMPLY WITH REQUIREMENTS IN SECTION 202115. PART 3 - EXECUTION 3.1 INSPECTION A.GENERAL: VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK OF THIS SECTION. DO NOT INSTALL UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. 3.2 PREPARATION A.CLEANING OF MEDICAL GAS TUBING: IF PRECLEANED FITTINGS OR TUBING MUST BE RECLEANED BECAUSE OF EXPOSURE, HAVE SUPPLIER PERFORM THE FOLLOWING PROCEDURES: 1. CLEAN MEDICAL GAS T E 0 RF R TUBE AND FITTINGS VALVES GAGES AND OTHER COMPONENTS OF OIL, GREASE, AND OTHER READILY OXIDIZABLE MATERIALS AS REQUIRED FOR OXYGEN SERVICE ACCORDING TO CGA G -4.1. 2.SDM RBGTE BITRODUTHSATTN PRTTIOF 1�LF CEMALLT3 OF SODIUM TUBING AND PHOSPHATE IN HOT, ALKALINE-CLEANER-WATER GAL. OF WATER. *.SCRUB TO ENSURE COMPLETE CLEANING. b.RINSE WITH CLEAN, HOT WATER TO REMOVE CLEANING SOLUTION. B.FIELD MEASUREMENTS: FIELD VERIFY LOCATIONS OF NEW AND EXISTING WORK PRIOR TO COMMENCING WORK OF THIS SECTION. C.PROTECTION: PROTECT SURROUNDING AREAS AND SURFACES TO PRECLUDE DAMAGE FROM WORK OF THIS SECTION. 3.3 INSTALLATION, APPLICATION, ERECTION, AND PERFORMANCE A.GENERAL: INSTALL, APPLY, ERECT, AND PERFORM THE WORK IN ACCORDANCE WITH ARTICLE +QUALITY ASSURANCE° PROVISIONS SPECIFICATIONS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS AND DIRECTIONS. WHERE THESE MAY BE IN CONFLICT, THE MORE STRINGENT REQUIREMENTS GOVERN. B.DO NOT COVER UP OR ENCLOSE WORK UNTIL INSPECTED AND APPROVED. IF IN NON - COMPUANCE, UNCOVER WORK, REMOVE, AND PROVIDE NEW TO SATISFACTION OF A/E AT NO ADDITIONAL COST TO OWNER. 3.4 INDOOR PIPING AND COMPONENT INSTALLATION A.COMPLY WITH REQUIREMENTS IN SECTION 202110, NFPA 99, AND ASSE 6010. B.INSTALL PIPE SUPPORTS IN ACCORDANCE WITH MSS SP -69, SECTION 202115, OR NFPA 99 WHICHEVER IS MORE STRINGENT. PIPING NOT SUPPORTED BY OTHER PIPING. C.BRAZING PROCEDURES SHALL BE AS DETAILED IN NFPA 99 AND BRAZING SHALL BE PERFORMED BY BRAZERS QUALIFIED UNDER NFPA 99. D.MANUFACTURER. ND TSEALEDPONTTHEEJOB AMAIINTAIN CERTIFICATESTOF ORIGINSANDCOFBY PROPER PREPARATION AT THE JOB SITE ATTESTING THE ABOVE. E.USE OF FLUX WHEN MAKING JOINT BETWEEN COPPER TO COPPER PIPES AND FITTINGS NOT ACCEPTABLE. F.NITROGEN FOLLOWING PROCEDURE IN NFPA 991E ATPCOMPLLETION OF ANY WITH OIL OPEN PIPE ENDS USING EXTERNAL CAP. G.AVOID THREADED JOINTS IN PIPING SYSTEMS WHENEVER POSSIBLE. WHERE UNAVOIDABLE, MAKE UP MALE THREADS WITH POLYTETRAFLOUROFETHYLENE (SUCH AS TEFLON) TAPE. LIQUID SEALANTS NOT ACCEPTABLE. H.VACUUM SYSTEMS: 1.INSTALL MOISTURE POCKET AT LOW POINTS OF MAINS AND AT BASE OF VERTICAL RISER, CONSISTING OF A 1-1/4 INCH DROP LEG, 12 INCHES LONG WITH 3/8 INCH DRAIN VALVE. 2.MAKE BRANCH CONNECTIONS TO MAIN VACUUM PIPING ABOVE CENTERLINE OF MAIN LINE USING EITHER BRANCH CONNECTIONEINR LIEU OFF TEE( FIADDITION, TII ISTALL REMOVABLE CAP( AT BOTTOM OPENING OF CROSS FITTING FOR USE AS CLEANOUT. 3.SLOPE PIPING FROM SERVICE OUTLETS DOWN TO VACUUM PUMP SETS. I. MEDICAL GAS OUTLETS: 1. LOCATE OUTLETS 60 INCHES ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED ON ARCHITECTURAL DRAWINGS. CENTERLINE SPACING OF MULTIPLE OUTLETS MINIMUM 5 INCHES. 2.COORDINATE OUTLET PLACEMENT WITH OTHER TRADES. J. VALVES, ZONE VALVES, AND VALVE ASSEMBLIES: 1. LOCATE VALVES AND VALVE ASSEMBUES 60 INCHES ABOVE FINISHED FLOOR. 2.COORDINATE BOX PLACEMENT WITH OTHER TRADES. TAKE SPECIAL NOTE OF WALL CONSTRUCTION AND LENGTH OF WALL REQUIRED TO ACCOMMODATE PIPE DROPS TO VALVE BOXES. 3.2RORN MOVALVES LES THE FOLLOWING SAME SERVICE AREM LOCATED IN MON OXYGEN, VACUUM, MVA VES IF SHALL BE THE LOWER. 4. FOLLOWING MANUFACTURER'S RECOMMENDATIONS REGARDING REMOVAL OR DISASSEMBLY OF VALVES DURING BRAZING TO PREVENT DAMAGE TO SEATS AND SEALS. 5.INSTALL SWITCHES DOWNSTREAM OF MAIN ISOLATING VALVES. 3.5 EQUIPMENT CONNECTIONS A.CONNECT MEDICAL GAS PIPING TO MECHANICAL EQUIPMENT AS INDICATED ON THE DRAWINGS. COMPLY WITH EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. INSTALL SHUTOFF VALVE AND UNION FOR EACH CONNECTION AND DRAIN VALVE DRAIN CONNECTION. LOCATE UNIONS TO ALLOW REMOVAL OF EQUIPMENT WITHOUT PIPING BEYOND UNION. B.INSTALL RECEIVER FOR MEDICAL VACUUM SYSTEM WITH 3 VALVE BYPASS. 3.6 FLUSHING OF MEDICAL GAS PIPING A.AFTER COMPLETION OF PIPING INSTALLATION AND PRIOR TO PRESSURE TESTING FLUSH INTERIOR SURFACES BY INJECTING OIL -FREE COMPRESSED AIR OR DRY NITROGEN INTO OPEN ENDS OF PIPING JUST PRIOR TO MAKING FINAL CONNECTIONS TO EQUIPMENT AND OUTLET VALVES.. 3.7 PIPE MARKERS AND COLOR BANDS A.LABEL PIPING WITH NAME OF GAS SERVICE, IDENTIFICATION COLOR AND DIRECTION OF FLOW. WHERE NON- STANDARD PRESSURES ARE PIPED, LABEL FOR PRESSURE. COMPLY WITH REQUIREMENTS ON SECTION 200510 AND NFPA 99, WHICHEVER IS MORE STRINGENT, FOR LOCATION OF LABELS AND BANDS. B.LABEL NTREDENCOTRLEE �ORD'A HAER FR VFNFR R AND AREAS MIOADCOLD COINATE WITOWNO FINAL OOMAND AEA DESIGNATIONS. LABEL VALVES WITH NAME AND IDENTIFICATION COLOR OF GAS AND DIRECTION FLOW. 3.8 PRESSURE TESTING A.DO NOT CONCEAL PIPING UNTIL THOROUGHLY TESTED AND MADE TIGHT IN ACCORDANCE WITH NFPA 99. B.AFTER CONNECTIONS TO OUTLETS AND FINAL INSTALLATION OF PRESSURE ALARM DEVICES PRESSURE INDICATORS, LINE PRESSURE RELIEF VALVES MANUFACTURED ASSEMBLIES HOSES, AND SIMILAR DEVICES SUBJECT EACH SECTION OF PIPING SYSTEMS TO MINIMUM TEST PRESSURE OF 150 PSIG WITH OIL FREE, DRY NITROGEN. MAINTAIN TEST PRESSURE UNTIL EACH JOINT HAS BEEN EXAMINED FOR LEAKS. HYDROSTATIC TEST NOT ACCEPTABLE. C.REPAIR LEAKS THAT OCCUR AND RETEST. D.OF L S C USE OL (FREDNTREN PRERE F 20 REETMEDICA GA SYSTEMS. OIL DRY NITROGEN FINAL O PRESSURE TEST NORMAL OPERATING PRESSURE. E.AFTER PIPING SYSTEM IS FILED WITH TEST GAS, SUPPLY VALVE AND OUTLETS CLOSED, AND SOURCE OF TEST GAS DISCONNECTED, SYSTEM SHALL REMAIN LEAK -FREE FOR 24 HOURS. 1. ONLY ALLOWABLE PRESSURE CHANGES DURING 24 HOUR TEST PERIOD SHALL BE THOSE CAUSED BY VARIATIONS IN AMBIENT TEMPERATURE AROUND PIPING SYSTEM 2.RECORD AMBIENT TEMPERATURE AND SYSTEM PRESSURE AT BEGINNING AND END OF 24 HOUR TEST. F. AFTER 24 HOUR TEST IS COMPLETED, MAINTAIN MINIMUM 60 PSIG ON SYSTEMS. G.FURNISH GAGES, TOOLS, PUMPS, GASES AND ANY OTHER EQUIPMENT AND MATERIALS REQUIRED FOR TESTING. H.EXERCISE CARE TO KEEP TESTING EQUIPMENT AND MATERIALS OIL FREE. 3.9 CERTIFICATION OF SYSTEMS A.CONTRACTOR SHALL RETAIN AN INDEPENDENT TESTING AGENCY TO PERFORM TESTS AND EXAMINATIONS AND PROVIDE CERTIFICATION. B.AFTER INSTALLATION OF COMPLETE MEDICAL GAS SYSTEM, TEST SYSTEMS IN ACCORDANCE WITH NFPA 99 AND CGA P -2. C.CERTIFY THAT MEDICAL GAS SYSTEMS AS CONSTRUCTED FOLLOW GUIDELINES OF NFPA 99 FOR PLACEMENT AND APPLICABILITY OF VALVES AND ALARMS. 1. CERTIFY THAT BRAZING WAS CONDUCTED BY BRAZERS QUAUFIED TO ASSE 6010 AND HOLDING CURRENT MEDICAL GAS ENDORSEMENTS. 2.CERTIFY THAT BRAZING WAS CONDUCTED WITH NITROGEN PURGING. D.CERTIFY THAT NO CROSS CONNECTIONS EXIST BETWEEN SYSTEMS USING FOLLOWING PROCEDURES: 1. REDUCE SYSTEMS TO ATMOSPHERIC PRESSURE. 2.DISCONNECT SOURCES OF TEST GAS FROM SYSTEMS EXCEPT THE ONE SYSTEM TO BE CHECKED. 3.PSRESSSEURIZE TSYSTEM R WITH UOI OF 5b PRIG AIR, NITROGEN, OR THE GAS FOR WHICH THIS SYSTEM 4.WITH APPROPRIATE ADAPTERS MATCHING OUTLET LABELS CHECK EACH INDIVIDUAL STATION OUTLET OF SYSTEMS INSTALLED TO DETERMINE THAT TEST GAS IS BEING DISPENSED FROM ONLY OUTLETS OF THIS SYSTEM. 5' INCLUDE SYSTEM WITHO OTHER( MEDICAL, GAS IS SYSSTEM CROSS CONNECTION TESTING SHALL 6.DISCONNECT SOURCE OF T GAS G S AND REDUCE SYSTEM TESTED T STE TO ATMOSPHERIC HER C PRESSU RE. 7.PROCEED TO TEST EACH ADDITIONAL PIPING SYSTEM IN ACCORDANCE WITH ABOVE PROCEDURES. E. CERTIFY THAT MEDICAL GAS PIPING SYSTEMS HAVE BEEN PURGED, PRESSURE TESTED, ANALYZED, AND PROVEN LEAK FREE IN ACCORDANCE WITH NFPA 99. F.CERTIFY THAT ALARM SYSTEM COMPONENTS FUNCTION PROPERLY. 1. DOCUMENT CONTROL ZONES AND SURVEILLANCE AREAS OF ALARMS. 2.VERIFY LOCATION OF EACH ZONE ON RECORD DRAWINGS. 3.REPORT AND RECORD DISCREPANCIES. G.CERTIFY THAT OUTLETS ARE DELIVERING GAS AT PRESSURE AND FLOW CONSISTENT WITH ANTICIPATED CGA ORENFPA 99 REQUIREMENTS RESPONSIBLE EACHROUTLWITHIN T W WITH�APPROPRIATE CASE ANALYZER AND DOCUMENT CONCENTRATIONS FOUND. H.CERTIFY THAT SYSTEM COMPONENTS PERFORM TO MANUFACTURER'S DESIGN SPECIFICATIONS AND PIPELINES ARE FREE OF DEBRIS, INCLUDING WATER. I. CERTIFY THAT DELIVERED GAS IS AS PURE AS REQUIRED BY APPLICABLE CGA /USP SPECIFICATIONS FOR BREATHING GAS. J. CERTIFY THAT MEDICAL AIR IS DRY AS SPECIFIED. K.CERTIFY THAT VACUUM SYSTEM PERFORMS AS SPECIFIED. L. RETEST AFTER CONTRACTOR HAS CORRECTED DEFICIENCIES FOUND. M.[ _WHERE NEW MEDICAL GAS PIPING CONNECTS TO EXISTING, TESTING AGENCY SHALL TEST PIPING INCLUDING EXISTING TO ENSURE IT HAS NOT BEEN CONTAMINATED.] N.TESTING AGENCY rSHALL] [WILL] FURNISH TEST EQUIPMENT AND SUPPUES INCLUDING MEDICAL GASES USED IN TESTING. 3.10 COMMISSIONING A.EQUIPMENT AND SYSTEMS REFERENCED IN THIS SECTION SHALL BE COMMISSIONED PER SECTION 200800. CONTRACTOR HAS SPECIFIC RESPONSIBILITIES FOR SCHEDULING, COORDINATION, TEST DEVELOPMENT TESTING AND DOCUMENTATION. COORDINATE COMMISSIONING ACTIVITIES WITH THE COMMISSIONING AUTHORITY. END OF SECTION 226313 REVIEWED FOR CODE COMPLIANCE APP 4nwE} DEC 10 2010 City of Tukwila BUILDING Oninnwl 1 ECEIVFD OCT 13 2' "7 P RMITCENTEF MECHANICAL SPECIFICATIONS N REVISIONS CO 0 N M 4 � *o2) 4 v ( (O (O - N N • 4- (0 0 0 ct z W W U J W z Lu 0 LL! U z O F- z 2 U� J TECTURE NAC NO 121 -10017 HEINO 10113 DRAWN JMR CHECKED RKE DATE 9 -10 -2010 0.5 U ui U rn 0 z J 0 o (n Q� CO C) ' *� O CO O % N O � = o o lil a- m wQ w oM ow J J CL LT: DIVISION 23 SECTION 230900 - TEMPERATURE CONTROLS PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES DESIGN COMPONENTS, HARDWARE AND CONSTRUCTION FOR COMPLETE INSTALLATION OF AN OPERATIONAL CONTROL SYSTEM. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY, AND STATE CODES AND ORDINANCES. B.CODES AND STANDARDS: 1. APPLICABLE ENERGY CODE. 2. AMCA STANDARD 500 -D, LABORATORY METHODS OF TESTING DAMPERS FOR RATING. 3. AMCA PUBLICATION 511 CERTIFIED RATINGS PROGRAM FOR AIR CONTROL DEVICES. 4. CSA, CANADIAN STANDARDS ASSOCIATION. 5. FCC, PART 15 SUBPART J CLASS A COMPUTING DEVICES. 6. NFPA 70, NATIONAL ELECTRICAL CODE. 7. UL 873, STANDARD FOR TEMPERATURE- INDICATING AND - REGULATING EQUIPMENT. 8. UL 916, STANDARD FOR ENERGY MANAGEMENT EQUIPMENT. C.CONTROL SYSTEM SUBCONTRACTOR'S QUALIFICATIONS: SUBCONTRACTOR THAT WILL N PERFORM THIS WORK SHALL HAVE A MINIMUM OF AT LEAST 3 CONTROL SYSTEMS OF SAME TYPE AND DESIGN AS REQUIRED BY THE CONTRACT. D. INSTALLATION: SYSTEM DESIGNED AND CONSTRUCTED BY AUTHORIZED REPRESENTATIVE OF PRODUCT MANUFACTURER. CAREFULLY INVESTIGATE MECHANICAL ELECTRICAL, AND FINISH CONDITIONS THAT COULD AFFECT WORK TO BE PERFORMED AND FURNISH MATERIALS AND LABOR NECESSARY TO MEET SUCH CONDITIONS. 1.3 SUBMITTALS A.PRODUCT DATA: SUBMIT SPECIFICATION DATA SHEET FOR EACH COMPONENT. IDENTIFY COMPONENTS BY TAG NUMBERS. B.SHOP DRAWINGS: AFTER APPROVAL OF PRODUCT DATA, SUBMIT SHOP DRAWINGS. LABEL COMPONENTS WITH TAG NUMBERS. DO NOT COMMENCE INSTALLATION UNTIL SHOP DRAWINGS ARE ACCEPTED BY A /E. C.RECORD DOCUMENTS: SUBMIT SHOP DRAWINGS FOR EACH CONTROL SYSTEM SHOWING INSTALLED CONDITION. AS A MINIMUM, INCLUDE DIAGRAMS AND DOCUMENTS LISTED IN PARAGRAPH "SHOP DRAWINGS" WITH SEQUENCES OF OPERATION. 1.4 OPERATION AND MAINTENANCE MANUAL A.FUNCTIONAL DESIGN: OPERATIONAL REQUIREMENTS OF SYSTEM, THEORY OF OPERATION, DESIGN PHILOSOPHY AND SPECIFIC FUNCTIONS. B.HARDWARE: GENERAL DESCRIPTION AND SPECIFICATIONS AND INSTALLATION AND CHECKOUT PROCEDURE. C.OPERATION: PROCEDURES AND INSTRUCTIONS FOR OPERATION OF SYSTEM. D.PERIOD C PREVENTATIVE MAINTENANCE N FAULTCDIAGNOSIS,AND EQUIPMENT INCLUDING REPIACEMEINNT OF DEFECTIVE COMPONENTS. 1.5 WARRANTY A.INCLUDE SERVICES MATERIALS AND EQUIPMENT NECESSARY FOR THE SUCCESSFUL OPERATION OF CONTROL SYSTEM FOR PERIOD OF ONE YEAR AFTER SUBSTANTIAL COMPLETION DATE. B.ADJUSTMENT, REQUIRED TESTING AND REPAIR OF THE SYSTEM INCLUDES COMPUTER EQUIPMENT TRANSMISSION EQUIPMENT AND SENSORS AND CONTROL DEVICES. PART 2 - PRODUCTS 2.1 BASIC SYSTEM A.GENERAL: PROVIDE THERMOSTATS, SENSORS, WIRING, CONDUIT RELAYS TRANSMITTERS AND OTHER CONTROL DEVICES REQUIRED TO MAKE A COMPLETE AND OPERATIONAL CONTROL SYSTEM. MATERIAL AND EQUIPMENT STANDARD PRODUCTS OF MANUFACTURER REGULARLY ENGAGED IN MANUFACTURING OF SUCH PRODUCTS. 2.2 CONTROL WIRING A.GENERAL: 1. INCLUDE WIRE AND CABLE TRANSFORMERS CIRCUITS WIRING PROTECTION AND LABELS DRAWINGS AS REQUIRED FOR COMPLETE AND OPERABLE CONTROL SYSTEM INCLUDING WIRING TO TRANSFORMER PRIMARIES. 2. CONFORM TO NEC AND DIVISION 26 REQUIREMENTS. PART 3 - EXECUTION 3.1 CONTROL SYSTEM, GENERAL I A.DESCRIPTION: INSTALL DEVICES AND HARDWARE REQUIRED TO INSURE A COMPLETE AND OPERATING SYSTEM IN ACCORDANCE WITH THE SEQUENCES OF OPERATION. DEVICES SHALL BE EASILY ACCESSIBLE. 3.2 SEQUENCES OF OPERATION A.GENERAL: PROVIDE SEQUENCE OF OPERATION AS INDICATED ON THE DRAWINGS. 3.3 FIELD TESTING AND VERIFICATION A.FIELD TESTS: CALIBRATE FIELD EQUIPMENT AND DEVICES AND VERIFY EQUIPMENT AND SYSTEM OPERATION BEFORE PLACING THE AUTOMATIC TEMPERATURE CONTROL SYSTEM ON -LINE. B.PERFORMANCE VERIFICATION TESTS: 1. CONDUCT PERFORMANCE VERIFICATION TESTS TO DEMONSTRATE THAT SYSTEM PROGRAMMED FOR TCORRECT SEQUENCES ARE TUNED, DRATIOND CONTROLLERS ARE END OF SECTION SECTION 233113 - AIR DISTRIBUTION PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES SHEET METAL WORK AND ASSOCIATED APPURTENANCES. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY AND STATE CODES AND ORDINANCES. B.CODES AND STANDARDS: 1. NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR - CONDITIONING AND VENTILATING SYSTEMS. C.DUCT CLEANLINESS REQUIREMENTS: 1. PREVENT DAMAGE TO DUCTS DURING TRANSPORTATION AND OFF LOADING. DELIVER ONLY WHEN DUCTS CAN BE STORED UNDER PERMANENT COVER. PLASTIC TARP COVERING OF DUCTS ON JOBSITE NOT ACCEPTABLE. R 2. KEEP SITE STORAGE AREAS CLEAN AND DRY WITH MINIMAL EXPOSURE TO DUST. 3. KEEP WORKING AREA CLEAN AND DRY AND PROTECTED FROM WEATHER ELEMENTS. 4. PRIOR TO INSTALLATION OF INDIVIDUAL DUCT SECTIONS INSPECT TO ENSURE THEY ARE FREE FROM DEBRIS AND WIPE INTERNAL METAL SURFACES. 5. COVER DUCT RISERS TO PREVENT ENTRY OF DEBRIS. 6. COVER OPEN ENDS OF DUCTS AND DOWNWARD FACING AND HORIZONTAL DUCT OPENINGS. 7. IF IN THE OPINION OF THE A/E, DUCTS AND FITTINGS ARE NOT KEPT CLEAN OR COMPLETELY DRY, REPLACE DUCTS AND FITTINGS OR CLEAN INTERIOR OF AFFECTED DUCTS AND FITTINGS TO SATISFACTION OF THE A/E AT NO ADDITIONAL COST TO THE OWNER. 1.3 SUBMITTALS A.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH ITEM SPECIFIED IN THIS SECTION. B.TEST REPORTS: PRESSURE TESTING FOR LEAKAGE. 1.4 PRODUCTS INSTALLED BUT NOT FURNISHED UNDER THIS SECTION A.SECTION 200548 - VIBRATION ISOLATION AND SEISMIC CONTROL: FLEXIBLE CONNECTORS. B.SECTION 230900 - TEMPERATURE CONTROLS: MOTOR OPERATED DAMPERS AND ACTUATORS. C.SECTION 283111 - FIRE ALARM AND DETECTION SYSTEMS: DUCT SMOKE DETECTORS. PART 2 - PRODUCTS 2.1 SHEET METAL WORK, GENERAL A.DUCT CONSTRUCTION: 1. COMPLY WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE ( SMACNA), THIRD EDITION, 2005. STANDING SEAMS NOT ACCEPTABLE FOR EXPOSED DUCTS. 2. GALVANIZED STEEL IN GENERAL WITH G -90 ZINC COATING, ASTM A 653, MINIMUM 26 GAGE. 3. GALVANIZED STEEL PREPPED OR DUCTS FINISHED WITH PAINT GRIP FOR FIELD PAINTING WHERE EXPOSED IN FINISHED SPACES AS SCHEDULED IN DIVISION 9. B.PRESSURE CLASSIFICATIONS: 1. RETURN AND EXHAUST DUCTS: PLUS 2 INCH DOWNSTREAM OF FANS AND MINUS 2 INCH W.G. UPSTREAM OF FANS FOR FAN DESIGN STATIC PRESSURE SCHEDULED ON THE DRAWINGS AT 1.0 INCH W.G. AND ABOVE. 2. RETURN RELIEF, AND EXHAUST DUCTS: PLUS 1 INCH DOWNSTREAM OF FANS AND MINUS 1 INCH W.G. UPSTREAM OF FANS FOR FAN DESIGN STATIC PRESSURE SCHEDULED ON THE DRAWINGS AT LESS THAN 1.0 INCH W.G. PLUS 1 INCH W.G. FOR RELIEF DUCTS. 3. SUPPLY DUCTS NOT LISTED ABOVE: 2 INCH W.G. 4. TRANSFER DUCTS: 0.5 INCH W.G. C.ROUND DUCTS: SPIRAL SEAM WITH BEADED SLEEVE AT TRANSVERSE JOINTS. D.FITTINGS: 1. COMPLY WITH SMACNA AS FOLLOWS: a.ROUND ELBOWS: FULL RADIUS (R /D =1.5), 5 PIECE SEGMENTED OR STAMPED PER SMACNA FIGURE 3 -4. b.RECTANGULAR ELBOWS: FULL RADIUS (R /W =1.5) WHERE MINIMUM 5 DUCT WIDTHS IS AVAILABLE DOWNSTREAM OF ELBOW FITTING PRIOR TO BRANCH TAKE OFF. IF STRAIGHT LENGTH NOT AVAILABLE, USE SQUARE THROAT ELBOW WITH TURNING VANES. c.ROUND TEES AND LATERALS: CONICAL FITTING OR TAP PER SMACNA FIGURE 3 -6 90 DEGREE TEE WITH OVAL TO ROUND TAP, 45 DEGREE LATERAL FITTING TAP OR SADDLE TAP, OR 45 DEGREE RECTANGULAR LEAD -IN PER SMACNA FIGURE 3 -5. 90 DEGREE TEE NOT ACCEPTABLE. SADDLE TAP CONNECTIONS FOR EXPOSED DUCTS IN FINISHED SPACES NOT ACCEPTABLE. d.ACCESSORIESING INCLUDE INSULATION WITH INSTALLRATIONAINT�DUCTNWITH LINING. e.RECTANGULAR LATERALS: 45 DEGREE ENTRY FITTINGS PER SMACNA FIGURE 4 -6. f. OFFSETS: FULL RADIUS (R D =1.5 FOR ROUND AND FLAT OVAL AND R /W =1.5 FOR RECTANGULAR) WHERE SPACE ALLOWS. MITERED OFFSET (TYPE 2) WITH 30 DEGREE MAXIMUM OFFSET ANGLE PER SMACNA FIGURE 4 -7. ANGLE OFFSET (TYPE 1) NOT ACCEPTABLE. g.DIVIDED FLOW FITTINGS ACCEPTABLE PER SMACNA FIGURE 4 -5 EXCEPT FOR BRANCH CONNECTIONS TO OUTLETS AND INLETS. 2. SCREENED OPENINGS: 1/2 INCH MESH SCREEN 14 GAGE GALVANIZED STEEL WIRE. ENCLOSE MESH SCREEN WITH 20 GAGE GALVANIZED REMOVABLE SHEET METAL FRAME AROUND PERIMETER. 3. DUCT COLLARS: 2 INCH WIDE GALVANIZED STEEL FOR GALVANIZED DUCTS 20 GAGE. MITERED CORNERS FOR SQUARE AND RECTANGULAR DUCTS. ESCUTCHEON TYPE FOR ROUND AND FLAT OVAL DUCTS. E.TURNING VANES: 1. DESCRIPTION: AIRFOIL DESIGN, SMOOTHLY - ROUNDED ENTRY NOSE EXTENDED TRAILING ADAPTABLE TO DUCTNSIZES. TUBES UM FOR SOUND RIGIDITY LEVEL 54 DECIBELS IN OCTAVE BAND 4 AT 2000 FPM VELOCITY IN 24 INCH BY 24 INCH DUCT SIZE. 2. ASSEMBLY FABRICATION: SIDE RAILS BY SAME MANUFACTURER AS TURNING VANES. VANES INSTALLED ON 2.4 INCH CENTERS ACROSS FULL DIAGONAL DIMENSION OF ELBOW PER SMACNA FIGURE 4 -3. RAIL SYSTEMS WITH NON- STANDARD TABLE SPACING NOT ACCEPTABLE. 3. UNEQUAL ELBOWS: FABRICATE AND ADJUST TO SET VANES IN ASSEMBLY AT CORRECT ANGLE OF ATTACK RESULTING IN LEADING AND TRAILING EDGES IN PARALLEL TO DUCT SURFACES. 4. MANUFACTURER: H.E.P. - HIGH EFFICIENCY PROFILE - AS MANUFACTURED BY AERODYNE CO. (1- 800 - 522 -2423 ) OR APPROVED. 5. AT CONTRACTOR'S OPTION, DOUBLE WALL TURNING VANES FABRICATED FROM SAME MATERIAL AS ADJACENT DUCT ACCEPTABLE. INCLUDE MOUNTING RAILS WITH FRICTION INSERT TABS THAT ALIGN VANES AUTOMATICALLY. F. ACOUSTICAL TURNING VANES: 1. DOUBLE THICKNESS PERFORATED GLASS FIBER FILL MYLAR LINER. 2. MANUFACTURER: DUCTMATE INDUSTRIES OR APPROVED. G.LINED DUCTS: FABRICATE WITH DUCT LINING SUCH THAT NO GAP WILL RESULT BETWEEN SECTIONS OF DUCT LINING AFTER ASSEMBLY OF DUCT SECTIONS. FABRICATION AND INSTALLATION SHALL RESULT IN ADJACENT LINING SECTIONS BUTTED TOGETHER WITHOUT GAPS, BULGES, OR OTHER DISCONTINUITIES. H.DUCT SEALER: 1. INDOOR LOCATIONS: UL 181 LISTED AND LABELED. LOW ODOR, NON -TOXIC VAPORS, SURFACE BURNING CHARACTERISTICS FOR MAXIMUM FLAME SPREAD OF 25 AND MAXIMUM SMOKE DEVELOPED OF 50 WHEN IN A DRY STATE. RATED FOR AIR TEMPERATURE RANGE OF MINUS 20 F TO PLUS 150 F. RATED TO 10 INCHES W.G., MINIMUM 65 PERCENT SOLID CONTENT. MCGILL AIRFLOW LLC, AIRSEAL UNITED DUCT SEALER (WATER BASED BIDDLE AQUA - CRYLIC HVAC, HARDCAST IRONGRIP 601, DESIGN POLYMERICS D 1 010, DUCTMATE INDUSTRIES PROSEAL OR EZ -SEAL, OR APPROVED. 2. OUTDOOR LOCATIONS: UL 181 LISTED AND LABELED. 3 INCH MINIMUM WIDTH. SURFACE BURNING CHARACTERISTICS OF 25 MAXIMUM FLAME SPREAD AND 50 MAXIMUM SMOKE DEVELOPED. RATED FOR AIR TEMPERATURE RANGE OF MINUS 40 F TO PLUS 200 F. SEALER WITH UV INHIBITORS. MCGILL AIRFLOW LLC, AIRSEAL UNI- WEATHER, DUCTMATE INDUSTRIES PROSEAL OR APPROVED. 2.2 FLEXIBLE DUCTS A.DESCRIPTION: FACTORY - INSULATED WITH LOW PERMEABILITY VAPOR BARRIER JACKET CONSTRUCTED OF REINFORCED METALLIZED LAMINATE FILM SUITABLE FOR MEDIUM AND SPRING PRESSURE REINFORCEMENT BONDEDTTO FIBERS FIBER CINSULATION, STERTOR STEEL LINER. 1. RATINGS: UL LISTED AND LABELED PER UL 181 AS A CLASS 1 FLEXIBLE DUCT WITH MAXIMUM FLAME SPREAD RATING 25, MAXIMUM SMOKE - DEVELOPED RATING 50. 2. LENGTH: ASSEMBLIES IN 5 FOOT LENGTH WITH GALVANIZED MALE AND FEMALE FITTINGS ATTACHED TO LINER AND VAPOR BARRIER JACKET ACCEPTABLE. B.MANUFACTURERS: THERMAFLEX MK -E, WIREMOLD 57K, FLEXMASTER 8M, OR APPROVED. 2.3 FASTENERS A.DESCRIPTION: USE BLIND RIVETS SHEET METAL SCREWS OR BOLTED CONNECTIONS WHERE REQUIRED BY SMACNA FOR ATTACHMENT PURPOSES FOR SHEET METAL. SHEET METAL SCREWS AND RIVETS MINIMUM LENGTH REQUIRED FOR SECURE FASTENING. WHERE RIVETS ARE SPECIFICALLY CALLED FOR IN THIS SECTION, SHEET METAL SCREWS MAY BE USED. B.LOCATIONS: FOR DUCTS, GRILLES AND ACCESSORIES EXPOSED TO VIEW IN FINISHED ROOMS INCLUDE FINISH -TYPE FASTENERS. 1. PERMANENT WORK: BLIND STAINLESS STEEL POP RIVETS. 2. REMOVABLE ITEMS AND GRILLES: CADMIUM - PLATED PAN HEAD OR COUNTERSUNK TAPPING SCREWS. 2.4 HANGERS FOR SHEET METAL WORK A.DESCRIPTION: SAHANGERS, IIAL,ASOFOR' AND ACONSTRUBCTION. FOR SHEET METAL WORK AND B.BUILDING ATTACHMENTS: CONCRETE INSERTS AND STRUCTURAL -STEEL FASTENERS APPROPRIATE FOR CONSTRUCTION MATERIALS TO WHICH HANGERS ARE BEING ATTACHED. COMPLY WITH REQUIREMENTS IN SECTION 200515. C.DUCT SIZES: REFER TO MAXIMUM CROSS- SECTION DIMENSION AT LOCATION OF HANGERS. D.HORIZONTAL RECTANGULAR AND ROUND DUCTS: COMPLY WITH SMACNA STANDARDS. WIRE HANGERS NOT ACCEPTABLE. E. VERTICAL DUCTS: ANGLES ATTACHED TO SIDES IN PAIRS. COMPLY WITH SMACNA. 2.5 VOLUME DAMPERS AND QUADRANTS A.GENERAL: FABRICATE IN ACCORDANCE WITH SMACNA, SAME MATERIAL AS FOR DUCT CONSTRUCTION. E.REMOTE CABLE CONTROL SYSTEM FOR QUADRANTS WHERE DUCTS ARE NOT ACCESSIBLE. CABLE SYSTEM FOR REMOTE OPERATION OF VOLUME DAMPER CONSISTING OF BOWDEN 0.054 INCH SHEATHED STAINLESS STEEL CONTROL WIRE, RACK AND PINION GEAR DRIVE, AND WALL MOUNTED CONTROL KIT. C.MANUFACTURERS: YOUNG REGULATOR, ENERTECH, OR APPROVED. 2.6 BACKDRAFT DAMPERS A.DESCRIPTION: EXTRUDED ALUMINUM FRAME AND BLADES EXTRUDED VINYL EDGE SEALS I - MECHANICALLY LOCKED INTO BLADE EDGE. BLADES WITH FIELD ADJUSTABLE ZINC PLATED STEEL COUNTERBALANCE WEIGHTS TO ALLOW PRESSURE RELIEF TO START OPENING AT 0.01 INCH W.G. AND BE FULLY OPEN AT 0.06 INCH W.G. CORROSION RESISTANT BEARINGS, SYNTHETIC TYPE. LINKAGE CONCEALED IN FRAME. DAMPERS DESIGNED FOR MAXIMUM 1500 FPM SPOT VELOCITIES AND UP TO 4 INCH W.G. BACK PRESSURE. B.MANUFACTURERS: RUSKIN MODEL CBD2, GREENHECK, AMERICAN WARMING & 2.7 VENTILATING, AIR FRAMES DYNE, PACIFIC AIR PRODUCTS, OR APPROVED. A.GENERAL: INCLUDE ACCESS DOORS WHEREVER ACCESS TO DUCTS IS NECESSARY FOR REACHING EQUIPMENT. DOUBLE CONSTRUCTION, HEMMED EDGES (NO SHARP EDGES TIGHT FITTING WITH GASKET, HINGED, WITH LATCH, INSULATION OR LINING EQUIVALENT TO THAT OF ADJACENT DUCT. STEEL ANGLE FRAME. ACCESS PANELS WITH SHEET METAL FASTENERS NOT ACCEPTABLE. B.LATCHES: DIE -CAST, VENTFABRICS NO. 100 FOR DOORS 2' -0" HIGH AND SMALLER. CAT. NO. 260 FOR DOORS UP TO 3' -0" HIGH. CAT. NO. 310 FOR DOORS HIGHER THAN 3' -0 ". USE 2 FOR EACH DOOR. CAM LATCHES ACCEPTABLE. N MISCELLANEOUS DUCT • ACCESSORIES 2.8 MISCELLA E A.INSTRUMENT TEST HOLES: CAST IRON OR CAST ALUMINUM TO SUIT DUCT MATERIAL, INCLUDING SCREW CAP AND GASKET. SIZE TO ALLOW INSERTION OF PITOT TUBE AND OTHER TESTING INSTRUMENTS AND OF LENGTH TO SUIT DUCT - INSULATION THICKNESS. PART 3 - EXECUTION 3.1 DUCT INSTALLATION A.GENERAL: 1. INSTALL IN WORKMANLIKE MANNER. FABRICATIONS FITTINGS, JOINTS, TAKE -OFFS, ATTACHMENTS, TURNING SMACNANAS, DAMPERS, INNTHIS�SECTION ANDOASAINDICATED ON THE DRAWINGS. 2. COMPLY WITH REQUIREMENTS IN SECTION 200548 FOR SEISMIC RESTRAINTS OF DUCTS. 3. HANG DUCTS FROM ROOF STRUCTURE AND NOT FROM THE ROOF DECK ITSELF. PROVIDE SUPPLEMENTARY STEEL FRAMING AS SPECIFIED IN SECTION 200515 TO SPAN BETWEEN ROOF STRUCTURAL MEMBERS. 4. LOCATE DUCTS WITH SUFFICIENT CLEARANCE AROUND EQUIPMENT TO ALLOW FOR INSPECTION REPAIR REPLACEMENT AND SERVICE. 5. CAP INCOMPLETED DUCT ENDS WITH TEMPORARY CLOSURES OF TAPED POLYETHYLENE TO PREVENT CONSTRUCTION DUST FROM ENTERING DUCTS. 6. INSTALL DUCT COLLARS WHERE EXPOSED DUCTS PASS THROUGH NON -FIRE RATED WALLS AND CEILINGS. FASTEN TIGHT TO DUCTS. 7. DUCT SIZES MAY BE CHANGED AS LONG AS THE NEW DIMENSIONS ARE EQUIVALENT TO THOSE INDICATED AND DO NOT EXCEED 4 TO 1 ASPECT RATIO. 8. TRANSITIONS: a.FABRICATE AND INSTALL DUCT TRANSITIONS FOR CONNECTIONS TO EQUIPMENT, SUCH AS FANS, HEATERS FIRE DAMPERS SMOKE DAMPERS COMBINATION FIRE SMOKE DAMPERS, IT MOTOR HEATERS, SIZESDINDIICATEDWONT�THET�DRI CONNECTION SIZES ARE b. MAINTAIN T EQUIVALENTAFREE REQUIRED TO DUCT SIZESAWIITH ANGLE SPACE, FABRICATE A15 TO DEGREES. 9. DRAWINGS DO NOT SHOW OFFSETS WHICH MAY BE REQUIRED. MAKE OFFSETS WITH FITTINGS WITH AS SMALL AN ANGLE OF OFFSET AS POSSIBLE. INSTALL TURNING VANES IN SQUARE CORNER ELBOWS. 10. INSTALL ACOUSTICAL TURNING VANES IN RETURN AIR SQUARE THROAT ELBOWS. 11. INSTALL FLANGED CONNECTIONS TO EQUIPMENT WITH NEOPRENE GASKETS. 12. INSTALL DUCTS THROUGH ROOF TO BE WATERTIGHT. COORDINATE WITH ANY DETAILS ON THE DRAWINGS AS TO FLASHINGS AND CURBS. REFER TO ARCHITECTURAL DRAWINGS FOR FLASHING DETAILS. 13. INSTALL DUCTS, UNLESS OTHERWISE INDICATED ON THE DRAWINGS, VERTICALLY AND HORIZONTALLY AND PARALLEL AND PERPENDICULAR TO BUILDING LINES. 14. INSTALL TEST HOLES AT FAN INLETS AND OUTLETS AND ELSEWHERE AS INDICATED ON THE DRAWINGS. LOCATE WHERE REQUIRED FOR TESTING AND BALANCING PURPOSES AS DIRECTED BY THE TAB SUBCONTRACTOR SPECIFIED IN SECTION 200593. 15. INSTALL RETURN AIR AND TRANSFER AIR OPENINGS ABOVE CEILINGS WITH MINIMUM 2' -0" CLEARANCE TO OBSTRUCTIONS. B.EXTERIOR DUCTS: 1. GENERAL: INSTALL DUCTS LOCATED OUTSIDE OF BUILDINGS IN WEATHERPROOF MANNER. 2. FABRICATION: FABRICATE AND USE GAGE AS REQUIRED BY SMACNA. GALVANIZED STEEL WITH 4 -BOLT OR CORNER -CLIP DUCT CONNECTIONS OR FLANGED JOINTS. SLOPE TOP OF DUCTS FOR DRAINAGE. SUPPORTS HOT DIP GALVANIZED AFTER FABRICATION. SEAL SEAMS AND JOINTS EXTERNALLY FOR WATERTIGHT INSTALLATION IN NEAT AND WORKMANLIKE MANNER. 3. CLEANING: THOROUGHLY CLEAN DUCT SURFACES, SUCH THAT DUCTS MAY BE PRIMED AND FINISH PAINTED. C.FLEXIBLE CONNECTORS: 1. INSTALL FLEXIBLE CONNECTORS FURNISHED UNDER SECTION 200548 AT CONNECTIONS TO VIBRATION - ISOLATED SPRING AND RUBBER ISOLATOR- MOUNTED) 2. SUPPORT DUCT OE AND EXIBLE SIMILAR EQUIPMENT. ENSURE ALIGNMENT AND TO AVOID BINDING CONNECTOR. 3. INSTALL WITH SUFFICIENT SLACK TO PERMIT 2 INCH HORIZONTAL OR VERTICAL MOVEMENT WITHOUT STRETCHING FABRIC AND TO EFFICIENTLY ISOLATE VIBRATION OF FANS FROM DUCTS. D.DUCT AND PLENUM SEALING: SMACNA SEAL CLASS A. APPLY DUCT SEALER TO TRANSVERSE JOINTS LONGITUDINAL SEAMS, FITTING CONNECTIONS CORNERS OF FOUR -BOLT OR CORNER CLIP DUCT CONNECTION SYSTEM, AND PITTING SEAMS EXCEPT CONTINUOUS WELDED TYPE. SPIRAL SEAMS, CONTINUOUS WELDED SEAMS, AND TRANSVERSE JOINTS FOR 4 -BOLT OR CORNER CLIP DUCT CONNECTION SYSTEM ARE NOT REQUIRED TO BE SEALED UNLESS VISIBLE AND AUDIBLE LEAKS EXIST OR DUCT LEAKAGE EXCEEDS THAT ALLOWED BY LEAKAGE TEST SPECIFIED IN THIS SECTION. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS. 3.2 FLEXIBLE DUCTS A.INSTALL PER SMACNA FIGURES 3 -10 AND 3 -11. B.CONNECT TO METAL DUCTS WITH SLIP JOINT MADE USING FIRE - RESISTANT MASTIC AND STAINLESS STEEL OR PLASTIC MACHINE - APPLIED CLAMP. C.FIVE FOOT MAXIMUM LENGTH, FULLY EXTENDED. GENERALLY INSTALL WITH STRAIGHT SECTIONS, WITHOUT BENDS. ' IF BENDS ARE REQUIRED, INSTALL WITH MAXIMUM ONE -90 DEGREE IN STRAIGHT FLEXIIBLE DUCT RUNS ACCEPTABLE WED. SHEET METAL ELBOWS TO D.HANG FLEXIBLE DUCT ON 5' -0" CENTERS AND AT 90 DEGREE BEND WITH 1 INCH WIDE FLAT STEEL STRAP. MAXIMUM 1/2 INCH SAG PER FOOT. SUPPORT SHALL NOT CAUSE OUT -OF -ROUND SHAPE. E.INSTALLATION IN CORRIDOR CEILING SPACES WHERE FIRE RATING IS REQUIRED NOT ALLOWED. 3.3 VOLUME DAMPERS A.GENERAL: VOLUME DAMPERS MAY NOT BE SHOWN ON THE DRAWINGS. INSTALL DAMPER IN DUCT TO EACH SUPPLY, RETURN, AND EXHAUST OPENING AND FOR BRANCH MAINS SERVING MORE THAN 1 OPENING. B.CONSTRUCTION: TIGHT FITTING TO WALLS OF DUCT WHEN FULLY CLOSED. INSTALL BEARING ON EACH END AND SEALED AIRTIGHT. RTIGHT. C.LOCATION: INSTALL DAMPERS IN ACCESSIBLE LOCATIONS. IN GENERAL, ARRANGE WITH AXIS OF BLADE IN LONG DIMENSION OF DUCT. LOCATE AS FAR FROM OUTLET AND INLET AS POSSIBLE. D.SETTING: SET AND LOCK IN FULL OPEN POSITION, PRIOR TO TAB WORK. E.INSTALL 12 INCH LONG ORANGE COLORED 1/2 INCH WIDE SURVEYORS TAPE ON QUADRANT OF VOLUME DAMPERS LOCATED ABOVE CEILINGS. 3.4 BACKDRAFT DAMPERS A.GENERAL: INSTALL AT EXHAUST AND RELIEF AIR DUCT TERMINATIONS TO ATMOSPHERE THAT DO NOT HAVE MOTOR OPERATED DAMPERS. 3.5 ACCESS DOORS A.GENERAL: INSTALL AT DUCT SMOKE DETECTORS HUMIDIFIER ABSORPTION MANIFOLDS, BACKDRAFT DAMPERS, MOTOR OPERATED DAMPERS, FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE /SMOKE DAMPERS, BOTH SIDES OF DUCT MOUNTED HEATERS AIRFLOW MEASURING UNITS AND PLENUMS. ARRANGE DOOR SWINGS SO THAT ACCESS BOORS OPEN AGAINST AIR PRESSURE. 3.6 DUCT SMOKE DETECTORS A.COORDINATE LOCATION REQUIREMENTS WITH DIVISION 28 WORK PRIOR TO PREPARING AND SUBMITTING SHEET METAL SHOP DRAWINGS TO ENSURE WITH DETECTOR MANUFACTURER'S INSTALLATION REQUIREMENTS. 3.7 PRESSURE TESTING FOR LEAKAGE A.DESCRIPTION: TEST MACNALYI-EVAC AIRNDUCTD LEAKAGE TESTTMANUAL, 1ST ED., 1985. C.TEST PROCEDURES: 1. TEST DUCT BEFORE INSULATION IS INSTALLED. 2. CLOSE OFF AND SEAL OPENINGS IN DUCT SECTION TO BE TESTED. CONNECT TEST APPARATUS TO DUCT BY MEANS OF FLEXIBLE DUCT. 3. TEST FOR AUDIBLE LEAKS. 4. AFTER AUDIBLE LEAKS HAVE BEEN SEALED RETEST. SEAL AND RETEST AS NECESSARY UNTIL MAXIMUM LEAKAGE IS LESS THAN 2 PERCENT OF DESIGN AIR QUANTITY OF SYSTEM HAS BEEN ACHIEVED. END OF SECTION SECTION 233713 - OUTLETS AND INLETS PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES GRILLES, DIFFUSERS, AND ASSOCIATED APPURTENANCES. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY, AND STATE CODES AND ORDINANCES. B.CODES AND STANDARDS: 1. ADC 1062R4 AIR DIFFUSING EQUIPMENT CERTIFICATION RATING AND TEST MANUAL. 2. AMCA 511 CERTIFIED RATINGS PROGRAM FOR AIR CONTROL DEVICES. 3. ASHRAE 7b, METHOD OF TESTING FOR RATING THE PERFORMANCE OF AIR OUTLETS AND INLETS. 1.3 SUBMITTALS A.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH TYPE AND ASSOCIATED APPURTENANCES. PART 2 - PRODUCTS 2.1 GRILLES,REGISTERS, DIFFUSERS, LOUVERS, ROOF AND WALL CAPS A.EXCEPT AS OTHERWISE INDICATED FURNISH MANUFACTURER'S STANDARD GRILLES AND DIFFUSERS OF SIZE SHAPE, CAPACITY AND TYPE AS INDICATED ON THE DRAWINGS FOR COMPLETE INSTALLATION. B.PERFORMANCE: FURNISH GRILLES AND DIFFUSERS THAT HAVE AS MINIMUM, TEMPERATURE AND VELOCITY TRAVERSES THROW AND DROP, AND AND CRITERIA RATINGS FOR EACH GRILLE AND DIFFUSER TYPE AND SIZE AS LISTED IN MANUFACTURER'S CURRENT DATA. C.CEILING COMPATIBILITY: FURNISH WITH BORDER STYLES COMPATIBLE WITH ADJACENT CEILING SYSTEMS SPECIFICALLY MANUFACTURED TO FIT INTO CEILING MODULE WITH ACCURATE FIT AND ADEQUATE SUPPORT. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR TYPES OF CEILING SYSTEMS. D.SEISMIC RESTRAINTS FOR GRILLES AND DIFFUSERS WEIGHING LESS THAN 20 POUNDS: INCLUDE MEANS TO POSITIVELY ATTACH GRILLES AND DIFFUSERS TO CEILING GRID SYSTEM. E. MANUFACTURERS: GRILLES REGISTERS, DIFFUSERS: TITUS, KRUEGER, ANEMOSTAT, PART M 3 ALAI E, EES OR APPROVED. 3.1 INSPECTION A.GENERAL: VERIFY INSTALLATION CONDITIONS AS SATISFACTORY TO RECEIVE WORK OF THIS SECTION. DO NOT INSTALL UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. 3.2 PREPARATION A.FIELD MEASUREMENTS: FIELD VERIFY LOCATIONS OF NEW AND EXISTING WORK PRIOR TO COMMENCING WORK OF THIS SECTION. B.PROTECTION: PROTECT SURROUNDING AREAS AND SURFACES TO PRECLUDE DAMAGE FROM WORK OF THIS SECTION. 3.3, INSTALLATION, APPLICATION ERECTION, AND PERFORMANCE A.GENERAL: INSTALL, APPLY, ERECT, AND PERFORM THE WORK IN ACCORDANCE WITH "QUALITY QUALITY ASSURANCE PROVISIONS SPECIFICATIONS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS AND DIRECTIONS. WHERE THESE MAY BE IN CONFLICT, THE MORE STRINGENT REQUIREMENTS GOVERN. B.COORDINATE TO INTERFACE INCLUDING GRILLES ANDNDIFDFUSERSCWITH ACCESSORIES, AS WORK. C.INSTALL GRILLES AND DIFFUSERS WITH AIRTIGHT CONNECTION TO DUCTS AND TO ALLOW SERVICE AND MAINTENANCE OF ADJUSTABLE COMPONENTS AND FIRE DAMPERS. D.CEILING - MOUNTED OUTLETS AND INLETS: DRAWINGS INDICATE GENERAL ARRANGEMENT OF DUCTS, FITTINGS AND ACCESSORIES. GRILLE AND DIFFUSER LOCATIONS HAVE BEEN INDICATED ON THE DRAWINGS TO ACHIEVE DESIGN REQUIREMENTS FOR AIR VOLUME, LOCATIONS CRITERIA, AIRFLOW PATTERN, ARCHITECT PRESSURE REFLECDTEDP.CEILING PLANS. WHERE ARCHITECTURAL FEATURES OR OTHER ITEMS CONFLICT WITH INSTALLATION, NOTIFY A/E FOR DETERMINATION OF FINAL LOCATION. E. SEISMIC RESTRAINTS: 1. FOR GRILLES AND DIFFUSERS WEIGHING LESS THEN 20 POUNDS: POSITIVELY ATTACH GRILLE AND DIFFUSER TO CEILING GRID SYSTEM. 2. FOR GRILLES AND DIFFUSERS WEIGHING 20 TO 56 POUNDS: IN ADDITION TO POSITIVELY ATTACHING GRILLE AND DIFFUSERS TO CEILING GRID SYSTEM, INSTALL TWO NO. 12 GAGE HANGER WIRES CONNECTED TO GRILLES AND DIFFUSERS TO CEILING SYSTEM HANGER OR TO STRUCTURE ABOVE. 3. FOR GRILLES AND DIFFUSERS WEIGHING MORE THAN 56 POUNDS: SUPPORT DIRECTLY FROM STRUCTURE ABOVE. COMPLY WITH REQUIREMENTS IN SECTION 200548 FOR SEISMIC RESTRAINTS. 3.4 ADJUSTING F. AFTER INSTALLATION, ADJUST GRILLES AND DIFFUSERS TO AIR PATTERNS INDICATED ON THE DRAWINGS, OR AS DIRECTED, BEFORE STARTING AIR BALANCING. 3.5 CLEANING A.EXPOSED INSTALLATION TO GRILLES AND F DIRT RAND SMUDGEXPOSED OVEI AND PROVIDE NEW GRILLES AND DIFFUSERS THAT HAVE DAMAGED FINISHES. END OF SECTION SECTION 234100 - FILTERS PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES AIR FILTERS FOR AIR HANDLING EQUIPMENT AND ASSOCIATED APPURTENANCES. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: Q S. COMPLY WITH APPLICABLE CITY, COUNTY, AND STATE CODES AND ORDINANCES. B.CODES AND STANDARDS: 1. ASHRAE 52.1 GRAVAMETRIC AND DUST -SPOT PROCEDURES FOR TESTING AIR - CLEANING DEVICES USED IN GENERAL VENTILATION FOR REMOVING PARTICULATE MATTER. 2. ASHRAE 52.2 METHOD OF TESTING GENERAL VENTILATION AIR - CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE. 3. NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR - CONDITIONING AND VENTILATING SYSTEMS. 1.3 SUBMITTALS A.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH AIR FILTER AND APPURTENANCE. 1.4 SPARE MEDIA A.FOR AIR HANDLING UNITS AND PACKAGED HVAC EQUIPMENT AND SIMILAR EQUIPMENT WITH FILTERS: THREE SETS FOR EACH TYPE OF FILTER. ONE FOR INITIAL INSTALLATION ONE INSTALLED PRIOR TO THE TAB WORK SPECIFIED IN SECTION 200593, AND ONE DELIVERED TO THE OWNER AT SUBSTANTIAL COMPLETION. PART 2 - PRODUCTS 2.1 REPLACEABLE FILTERS A.PLEATED MEDIA TYPE: EXTENDED SURFACE WITH REINFORCED NON -WOVEN COTTON FABRIC IN SELF - SUPPORTING FRAME, MERV 8 PER ASHRAE 52.2, 2 INCHES THICK, UL CLASS 1. CAMFIL FARR 30/30, AAF INTERNATIONAL, OR APPROVED. 2.2 FINAL FILTER A.V -STYLE E EXTENDED SURFACE, MINIMUM MERV 14 PER ASHRAE 52.2, 12" THICK, UL CLASS 2.3 FILTER HOUSINGS AND FRAMES A.FOR AIR HANDLING EQUIPMENT: FILTER HOUSINGS AND FRAMES FURNISHED BY AIR HANDLING EQUIPMENT MANUFACTURER AND INTEGRAL TO AIR HANDLING EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWINGS. B.EXTERNAL FILTER HOUSING: TWO -STAGE FILTER HOUSING, 16 GAUGE GALVANIZED STEEL WEATHERPROOF FINISH. CAMFILL FARR 3P GLIDEPACK, OR APPROVED. 2.3 RESISTANCE INDICATOR A.GENERAL: DIAPHRAGM- ACTUATED DIAL TYPE 4-3/4 INCH OUTSIDE DIAMETER WITH WHITE DIAL BLACK FIGURES AND GRADUATIONS, AND POINTER ZERO ADJUSTMENT 0 TO 1 INCH W.O. RANGE WITH 0.02 INCH MINOR DIVISION. ACCURACY PLUS OR MINUS 2 PERCENT OFFULL SCALEAT7 70 F. INCLUDE BRACKET, STATIC PRESSURE TAPS, ALUMINUM UM TUBING AND VENT VALVES. MANUFACTURER: DWYER MAGNEHELIC MODEL PART 3 - EXECUTION 3.1 INSTALLATION, APPLICATION ERECTION, AND PERFORMANCE A.GENERAL: INSTALL, APPLY, ERECT, AND PERFORM THE WORK IN ACCORDANCE, SPECIFICATIONS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS AND DIRECTIONS. WHERE THESE MAY BE IN CONFLICT, THE MORE STRINGENT REQUIREMENTS GOVERN. B.COORDINATE WITH DUCTWORK AND AIR MOVING EQUIPMENT AS NECESSARY TO INTERFACE INSTALLATION OF AND ACCESS TO FILTERS. C.INSTALL FILTERS IN PROPER POSITION TO PREVENT PASSAGE OF UNFILTERED AIR. D.FILTERS SHALL BE EASILY CHANGED FROM FRAMES AND SHALL SLIDE FREELY ON TRACKS WITHOUT LANDING. E.FILTER SECTIONS SHALL HAVE HINGED ACCESS DOORS WITH LATCHES. F.INSTALL RESISTANCE INDICATOR STATIC PRESSURE TAPS UPSTREAM AND DOWNSTREAM OF FILTERS TO INDICATE AIR PRESSURE DROP THROUGH AIR FILTER. INSTALL INDICATOR ON OUTSIDE OF FILTER HOUSING OR FILTER PLENUM IN ACCESSIBLE AND READABLE POSITION. END OF SECTION SECTION 238100 - PACKAGED HVAC EQUIPMENT PART 1 - GENERAL 1.1 SECTION INCLUDES A.DESCRIPTION: WORK INCLUDES PACKAGED HVAC EQUIPMENT WITH MECHANICAL COOLING AND HEATING CAPABILITIES AND ASSOCIATED APPURTENANCES. 1.2 QUALITY ASSURANCE A.REGULATORY REQUIREMENTS: COMPLY WITH APPLICABLE CITY, COUNTY, AND STATE CODES AND ORDINANCES. B.CODES AND STANDARDS: 1. APPLICABLE ENERGY CODE. 2. ARI 210/240 PERFORMANCE RATING OF UNITARY AIR - CONDITIONING AND AIR SOURCE HEAT PUMP EQUIPMENT. 3. ARI 340/360, COMMERCIAL AND INDUSTRIAL UNITARY AIR - CONDITIONING AND HEAT PUMP EQUIPMENT. 4. NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR - CONDITIONING AND VENTILATING SYSTEMS. 1.3 SUBMITTALS TT LS A.PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA AND MAINTENANCE DATA FOR EACH TYPE OF PACKAGED HVAC EQUIPMENT AND APPURTENANCE. INDICATE ACCESSORIES WHERE REQUIRED FOR COMPLETE SYSTEM AND INSTALLATION INSTRUCTIONS. B.PERFORMANCE DATA: SUBMIT FAN PERFORMANCE CURVE FOR UNIT. INDICATE ON SEPARATE GRAPH FOR EACH FAN STATIC PRESSURE VERSUS VOLUME FLOW EFFICIENCY, AND BRAKE POINT 1. A 0 SINGLE AND LABELED. CURVE NOT ACCEPTABLE. C.SHOP DRAWINGS: SUBMIT PACKAGED HVAC EQUIPMENT CONTROL WIRING DIAGRAM INDICATING FACTORY AND FIELD INSTALLED WIRING. D.TEST REPORTS: 1. FACTORY START -UP AND TEST REPORTS. 2. FIELD START -UP AND TEST REPORTS. 3. INCLUDE COPY OF REPORTS IN THE OPERATION AND MAINTENANCE MANUAL. PART 2 - PRODUCTS 2.1 HVAC EQUIPMENT A.PROVIDE EQUIPMENT WITH ALL FEATURES AND OPTIONS LISTED ON EQUIPMENT SCHEDULES. TRANE, OR APPROVED. PART 3 - EXECUTION 3.1 WORK PRIOR TO INSTALLATION A.EQUIPMENT MANUFACTURER'S AUTHORIZED REPRESENTATIVE SHALL MAINTAIN PERSONNEL WITHIN A 50 MILE RADIUS OF JOB SITE. REPRESENTATIVE CAPABLE OF TROUBLESHOOTING PACKAGED HVAC EQUIPMENT FAULTS. 1. INCLUDE 1 MAN DAY TO MEET WITH THE MECHANICAL ELECTRICAL AND CONTROL SUBCONTRACTORS AT THE JOB SITE. SCHEDULE THIS MEETING WITHIN 1 WEEK AFTER EQUIPMENT IS DELIVERED TO FINAL LOCATION AT JOB SITE BUT PRIOR TO EQUIPMENT OPERATION. PURPOSE URPOSE IS TO ASSURE THAT ALL PARTIES UNDERSTAND WHAT INTERCONNECTIONS ARE REQUIRED. 2. AFTER EQUIPMENT INSTALLATION, INCLUDE 1 MAN DAY TO ASSIST CONTROL AND ELECTRICAL SUBCONTRACTORS IN THE TERMINATION OF THE INTERCONNECTING WIRES IN UNIT MOUNTED CONTROL PANELS. THIS SERVICE SHALL ALSO VERIFY THE PROPER CONNECTION AND POLARITY OF THE WIRES. 3.2 INSTALLATION OF PACKAGED HVAC EQUIPMENT AND COMPONENTS A.INSTALL EQUIPMENT WITH CLEARANCES FOR SERVICE AND MAINTENANCE. B.REPAIR DAMAGED CONDENSER COIL FINS. C.COORDINATE WITH DIVISION 26 TO INSTALL DISCONNECTS SO AS NOT TO INTERFERE WITH UNIT AND INTERNAL L C OMPONENT ACCESS AND FILTERS. D.ROOF MOUNTED EQUIPMENT: ATTACH ROOF CURBS TO ROOF AND MOUNT UNITS ON ROOF CURBS. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF FLASHING. E. COMPLY WITH REQUIREMENTS FOR VIBRATION ISOLATORS AND SEISMIC RESTRAINTS. 3.3 START -UP SERVICES A.EQUIPMENT MANUFACTURER'S AUTHORIZED REPRESENTATIVE SHALL PERFORM START -UP SERVICES OF PACKAGED HVAC EQUIPMENT AND RELATED APPURTENANCES. SERVICES SHALL INCLUDE A CHECK OF PROPER INSTALLATION, SYSTEM CHECK -OUT, ADJUSTMENT, AND COMPLETE START -UP. B.INCLUDE START -UP AND TEST REPORTS IN OPERATION AND MAINTENANCE MANUAL. END OF SECTION REVIEWED FOR CODE COMPLIANCE lam eviiF DEC 10 2U1U City of Tukwila BUILDING DIVISInM RECEIVED OCT 13 2010 PERMIT CENTER U C MECHANICAL SPECIFICATIONS o Q_ REVISIONS N 3 T- 2 0 0 z W 2 W U J W I-- z W 2 0_ W U Z a. z 2 Q U� >- I- 12 W W 11::11 Z TECTURE NAC NO 121 -10017 HEINO 10113 DRAWN JMR CHECKED RKE DATE 9 -10 -2010 ROOF MOUNTED HEAT PUMP SCHEDULE MARK LOCATION AREA SERVED MANUFACTURER / MODEL FILTER MANUFACTUER/ MODEL ELECTRICAL COOLING HEATING FILTER BOX DIMENSIONS ( HxWxD) (INxINxIN) MIN. OA (CFM) SUPPLY AIRFLOW ESP (IN) MOTOR HP ELECTRIC AUX. COIL UNIT VOLTAGE V / 0 MCA (A) MOCP (A) MBH EAT ('F) LAT ('F) MBH EAT ('F) LAT ('F) SEER REFRIG. TYPE DIMENSIONS (LxWxH) (INxINxIN) WEIGHT (LBS.) REMARKS STAGE 1 (kW) STAGE 2 (kW) HP -1 ROOF CT SCAN EXAM ROOM TRANE / WSC048 150 1500 0.75 1 9 12 208 / 3 63.7 70 45.9 75.7 52.5 26.8 68.2 85 13.0 R -410A 70x45x36 600 NOTE 1, 2, 3, 4 1. 2. 3. 4. NOTES DISCHARGE, HIGH STATIC MOTOR, ECONOMIZER, FACTORY ROOF CURB, AND MICROPROCESSOR FACTORY CONTROLS. 2 STAGE ELECTRIC HEATING COIL. THE BASE SINGLE POINT ELECTRICAL CONNECTION KIT. MCA AND MOCP ARE BASED UPON THE USE OF SINGLE POINT CONNECTION KIT TO POWER MOTORS AND ELECTRIC HEATING COIL. BALANCE AIRFLOW TO 1600 CFM. PROVIDE WITH HORIZONTAL PROVIDE WITH SUPPLEMENTARY PROVIDE WITH THROUGH BID ALTERNATE 2: IF ACCEPTED, FILTER BOX SCHEDULE MARK LOCATION AREA SERVED/ SYSTEM SERVED HOUSING MANUFACTURER/ MODEL FILTER MANUFACTUER/ MODEL AIRFLOW RATE (CFM) MAX VELOCITY (FPM) INITIAL MAX APD (IN) FILTER BOX DIMENSIONS ( HxWxD) (INxINxIN) FILTER SIZE (HxWxD) (INxIN) REMARKS F -1 ROOF HP -1 FARR / 3P GLIDEPACK VILEDON / MV95 1500 400 0.25 27x24x2L 24x24 NOTE 1, 2 1. 2. 3. NOTES REVIEWED FOR CODE COMPLIANCE FOR BOTH PREFILTER AND FINAL FILTER. V'a nUE DEC 10 2010 AIRFLOW WILL BE 1600 CFM. City of Tukwila ila BUILDING fRVlSInM PROVIDE MAGNAHELIC GAGES PROVIDE MERV 8 PRE - FILTER. BID ALTERNATE 2: IF ACCEPTED, AIR DEVICE SCHEDULE ROOM # MARK TYPE MANUFACTURER / MODEL SUPPLY / RETURN / EXHAUST BORDER TYPE NECK SIZE (L "xW ") (DIA) FACE SIZE (L "xW ") (IN) CFM RANGE < 25 NC BORDER TYPE FINISH MATERIAL REMARKS C1 CEILING DIFFUSER TITUS MCD SUPPLY LAY -IN 6 x 6 24x24 0 - 150 3 WHITE STEEL 1, 2 8 x 8 155 - 275 10 x 10 280 - 450 12 x 12 455 - 600 14 x 14 605 - 750 105 893 R1 RETURN GRILLE TITUS 350 RETURN LAY -IN 8 x 8 24x24 0 - 260 3 WHITE STEEL 1, 2 12 x 12 260 - 600 16 x 16 600 - 1130 1. 2. NOTES 4 -WAY THROW UNLESS INDICATED OTHERWISE ON PLANS. ARE NOMINAL REFER TO MANUFACTURER FOR ACTUAL DIMENSIONS. ADJUST DIFFUSERS FOR DIMENSIONS INDICATED AIR BALANCE / PRESSURIZATION SCHEDULE ROOM # ROOM NAME AREA (FT'i2) VOLUME (FT"3) AHU AIA /FGI GUIDELINES DESIGN AIRFLOW (CFM) REMARKS SA (ACH) (ACH) SA (CFM) (CFM) EA (ACH) (ACH) EA (CFM) (CFM) PRESS (1) SA (CFM) RA (CFM) EA (CFM) P (CFM) 164 CT SCAN 405 3443 HP -1 6 340 - - NA 1420 1420 0 0 NOTE 1, 3 165 CONTROL ROOM 105 893 AC -3 6 90 - - NA 480 480 0 0 1. NOTES E= EQUAL, NA = NOT APPLICABLE P = POSITIVE, N = NEGATIVE, PLUMBING FIXTURE SCHEDULE MARK FIXTURE COMPONENT FIXTURE TYPE/ DESCRIPTION MATERIAL MANUFACTURER MODEL NUMBER WASTE VENT COLD HOT REMARKS S -1 SINK COUNTER MOUNTED STAINLESS STEEL ELKAY LR1517 1 -1/2" 1 -1/4" - - NOTE 1, 2 FAUCET GOOSENECK SPOUT CHROME PLATED CHICAGO FAUCETS 786- E29VPCCP - - 1/2" 1/2" NOTE 1, 3 TRIM GRID AND TAILPIECE STAINLESS STEEL ELKAY - - - - - NOTE 1 1. 2. 3. NOTES: DIFFERENT THAN THE ACTUAL FIXTURE CONNECTION, PROVIDE BRANCH PIPE OF LISTED SIZE AND ALL PIPE FITTINGS REQUIRED FOR A COMLETE INSTALLATION. 304 STAINLESS STEEL, SATIN FINISH, FULLY UNDERCOATED FOR SOUND DAMPENING, 7 -5/8" DEEP BOWL, 3 HOLE PUNCHINGS FOR FAUCET ON 8" CENTERS. 5 -1/4" GOOSENECK SPOUT, POLISHED CHROME PLATED FINISH, PRESSURE COMPENSATING LAMINAR FLOW OUTLET, 4" WRIST BLADES. PIPE SIZES LISTED MAY BE SINK: 18 GAUGE, TYPE SINK FAUCET: 8" CENTERS, ECEIVED OCT 13 2010 PERMIT CENTEF U MECHANICAL EQUIPMENT SCHEDULES oa N REVISIONS CO 0 N_ • C�7 Cr) d; N 'd L (D CD CD - N N • 4-. CT EQUIPMENT REPLACEMENT, ROOM 164 TECTURE NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 JMR RKE 9 -10 -2010 RH -31 lh- )L Th :3E 5 J HVAC L1.dwg CD 9x9 170 I TO RAG E 7007 CT SCAN) 7OOlvi 9x9 65 _,OR EC) DOR J. 7017 FIRST FLOOR HVAC DEMOLITION PLAN STAID H1 E002 Scale: 1/4" = 1' -0" I—IJ I 0 1 2 4 1 8 — REVIEWED FOR CODE COMPLIANCE PPM` ?:9E, DEC 1 2010 i City of Tukwila BUILDING DIVISIfN SHEET NOTES: 1. DEMOLISH ALL DUCTWORK IN CT SCAN AND CT SCAN CONTROL ROOM. REFER TO M3.1 FOR POC'S AND CONNECTIONS TO EXISTING SYSTEMS. FLAG NOTES: EXISTING TEMPERATURE SENSOR FOR REHEAT COIL RH -31. RELOCATE TO NEW LOCATION AS INDICATED ON SHEET M3.1. DEMOLISH ALL EXISTING DUCTWORK ASSOCIATED WITH ABANDONED WATER COOLED SPLIT SYSTEM. FIELD VERIFY. DEMOLISH DUCT BACK TO THIS POINT AND PROVIDE TEMPORARY CAP. RECONNECT AND BALANCE PER M3.1. CAP DUCT ABOVE CEILING AT THIS LOCATION. REFER TO M3.1. ECEIVEr OCT 13 2210 PERMIT CENTEI- N KEY PLAN NOT TO SCALE REVISIONS CD 1- N ■ U c U FIRST FLOOR HVAC DEMOLITION PLAN 8 TECTURE u NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 JMR RKE 9 -10 -2010 18x10 " `/&4�ix/ . 9x9 65 _,OR EC) DOR J. 7017 FIRST FLOOR HVAC DEMOLITION PLAN STAID H1 E002 Scale: 1/4" = 1' -0" I—IJ I 0 1 2 4 1 8 — REVIEWED FOR CODE COMPLIANCE PPM` ?:9E, DEC 1 2010 i City of Tukwila BUILDING DIVISIfN SHEET NOTES: 1. DEMOLISH ALL DUCTWORK IN CT SCAN AND CT SCAN CONTROL ROOM. REFER TO M3.1 FOR POC'S AND CONNECTIONS TO EXISTING SYSTEMS. FLAG NOTES: EXISTING TEMPERATURE SENSOR FOR REHEAT COIL RH -31. RELOCATE TO NEW LOCATION AS INDICATED ON SHEET M3.1. DEMOLISH ALL EXISTING DUCTWORK ASSOCIATED WITH ABANDONED WATER COOLED SPLIT SYSTEM. FIELD VERIFY. DEMOLISH DUCT BACK TO THIS POINT AND PROVIDE TEMPORARY CAP. RECONNECT AND BALANCE PER M3.1. CAP DUCT ABOVE CEILING AT THIS LOCATION. REFER TO M3.1. ECEIVEr OCT 13 2210 PERMIT CENTEI- N KEY PLAN NOT TO SCALE REVISIONS CD 1- N ■ U c U FIRST FLOOR HVAC DEMOLITION PLAN 8 TECTURE u NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 JMR RKE 9 -10 -2010 9x9 CD 170 XTOPACI l20 2■6 70 \JI \I \ILJ`.JI 125 0 355 (TYP) (TYP 4) 710 :0 18x10 9x9 165 m • • • 8x6 95 HP 1 J /V X STIBLL : CD 10x6 165 J. 118 1 S eT 1 16 ALCOV T. 62 20x14 SA UP THROUGH ROOF 20x14 RA UP rTHROUGH ROOF ' INKOMMEN CT SC 12x8 I,.i I I IM NI I MI!! ii dlI L 1 %F„ fig; I3. 12x8 230 17 la F11..1 2 I bill L_J L Ll LI ■ CONTROL 1120 480 L 1 J "117 FIRST FLOOR HVAC PLAN T LT 1 RAS =XA 11 • UI \JD RH -31 140 • 7 1 0 0 :1 STAIR H, "l03 Scale: 1/4" = 1' -0" PZJ 1 0 1 2 4 8 SHEEP NOTES: 1. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO DEMOLITION AND CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE A/E PRIOR TO PROCEEDING WITH WORK. 2. BID ALTERNATE 2: BALANCE SUPPLY AIRFLOW AT EACH DIFFUSER TO 400 CFM AND EACH RETURN AIR GRILLE TO 800 CFM. FLAG NOTES: � lL dL1��Sewa„ CODE COMP; rA BLitt: v4!) f J City of Tukwila DING DIVISION ADJUST DIFFUSER FOR INDICATED FLOW PATTERN. NEW LOCATION FOR TEMPERATURE SENSOR FOR RH -31. PRIOR TO CONSTRUCTION, OBTAIN AIRFLOW READING FOR EXISTING GRILLE. AFTER COMPLETION OF CONSTRUCTION, REBALANCE EXISTING GRILLE TO PRE - CONSTRUCTION AIRFLOW QUANTITY. EXISTING CONCRETE BEAM IN CEILING SPACE. CONFIRM LOCATION IN FIELD AND PROVIDE ALL DUCT FITTINGS REQUIRED TO ROUTE DUCT UNDER BEAM AND ABOVE CEILING. WEST WING RECEIVEr OCT 13 2010 PERMITCENTEF N 2:: KEY PLAN NOT TO SCALE TO SCALE U E FIRST FLOOR HVAC PLAN 8 TECTURE NAC NO 121 -10017 HEINO 10113 DRAWN JMR CHECKED RKE DATE 9 -10 -2010 rn v Z a. Ii 0 0 0 I ix w(0 < 0 uJ Ld o 0 Q P0o O • O O . cua- m o �Z wQ Q w oQ I- Z ow J Q_ (E) RD (E) RD 0 0 OA LOCATION F -1 MECHANICAL ROOF PLAN (E) VTR 0 1 (E) COMBUSTION AIR VENT 67— (E) RTU (E) RTU 0 (E) EF (E) EF (E) GENERATOR EXHAUST STACK (E) EF (E) EF Scale: 1/4" = 1' -0" 1 01�12 4 8 SHEET NOTES: 1. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO DEMOLITION AND CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE WE PRIOR TO PROCEEDING WITH WORK. FLAG NOTES: PENETRATION THROUGH ROOF. REFER TO ARCHITECTURAL DRAWINGS. FLEXIBLE CONNECTION. DUCTWORK SUPPORT LOCATION. REFER TO ARCHITECTURAL DRAWINGS FOR SUPPORT DETAILS. MOUNT ON ROOF CURB. REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS. LOCATE UNIT PER ARCHITECTURAL DRAWINGS AND STRUCTURAL REQUIREMENTS. PROVIDE OFFSETS IN DUCT ON ROOF AS REQUIRED TO ALLOW DUCT INSTALLATION FROM HEAT PUMP TO DUCT PENETRATION THROUGH ROOF. REVIEWED FOR CODE COMPLIANCE DEC 10 2010 City of Tukwila BUILDING DIVISinM RECEIVEr OCT 13 2310 PERMIT CENTEI, PLAN KEY N KEY PLAN NOT TO SCALE 0 MECHANICAL ROOF PLAN 03 REVISIONS H C o " M ▪ .N L 0.3C0 ad m O a =� 1 1 iti C N N w'c . • " C 3 _ =a) cn 0 O co 0 0 z w w U J w I-- z 5w 0 w U TUKWILA, WASHINGTION 12844 MILITARY ROAD S TECTURE u NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 JMR RKE 9 -10 -2010 M 6.1 NOT USED M9.1 / SCALE: NO SCALE NOT USED M9.11 SCALE: NO SCALE NOT USED M9.1 / SCALE: NO SCALE NOT USED `9•1.1 SCALE: NO SCALE NOT USED M9.1 SCALE: NO SCALE M9.1 SCALE: NO SCALE NOT USED SCALE: NO SCALE BRANCH "X" DUCT SIZE DIMENSION 6" 13" 7" 14" 8" 15" 9" 16" 10" 17" 12" 19" 14" 21" NOTES: A. B. CEILING DIFFUSER OR RETURN GRILLE GALVANIZED STEEL DIFFUSER OR GRILLE BOX. C. SECURE TO DIFFUSER OR GRILLE NECK WITH SHEET METAL SCREWS, MIN. ONE PER SIDE OR EVERY 90 DEGREES; SEAL AIR TIGHT. D. DIFFUSER BOX SUPPORT, SUPPORT TO STRUCTURE, 2 PER BOX. E. EQUALIZING GRID FULL WIDTH OF DIFFUSER NECK. PERFORATED 20 GA GALVANIZED STEEL WITH .156" HOLES ON 3/16" STAGGERED CENTERS (63% FREE AREA). TOP AT HORIZONTAL CENTERLINE OF BRANCH DUCT. BOTTOM (H) AT 3" BELOW BOTTOM OF BRANCH DUCT. 1/2" HEM EDGE TOP AND BOTTOM. 3/4" 90' BEND EACH END AND MINIMUM 3 SPOT WELDS, RIVETS OR SCREWS TO BOX. EQUALIZING GRID NOT REQUIRED FOR RETURN GRILLES. (A) F. BRANCH DUCT — INSULATED FLEX. SEE BRANCH DUCT SIZING SCHEDULE FOR BRANCH DUCT RUNOUT SIZE. G. DUCT COLLAR SECURELY ATTACHED TO BOX. H. DUCT SUPPORT TO STRUCTURE PER SMACNA HVACDCS AND AS SPECIFIED. I. TYPICAL CEILING (TEE —BAR SUSPENDED CEILING SHOWN). J. LIGHT FIXTURE AS APPLICABLE. n CEILING DIFFUSER AND GRILLE INSTALLATION DETAIL SCALE: NO SCALE NOTE: 1. CONDENSATE DRAIN PAN SHALL POSITIVELY SLOPE DOWN TO PIPE OUTLET CONNECTION TO RESULT IN FREE AND COMPLETE DRAINAGE. CONDENSATE DRAIN PAN AND PIPE OUTLET CONNECTION REMOVABLE CLEANOUT PLUG OR CAP (TYP) - 6" L OPEN VENT — INVERT (OUTLET) INVERT Z REVERT • 2 "MIN SP ABOVE DRAIN PAN, IN. WG H, INCHES X, INCHES Z, INCHES —1 2 1 5 —2 3 1.5 6.5 —3 4 2 8 +1 1 2 5 +2 1 3 6 SP, INCHES W c'-\. EQUIPMENT INDIRECT DRAIN PIPING, SIZE PER CODE OR TO MATCH PAN CONNECTION SIZE (WHICHEVER IS LARGER) TO DISPOSAL POINT WITH 1" AIR GAP 2 COOLING COIL CONDENSATE DRAIN DETAIL REVIEWED FOR CODE COMP IAI\CE DEC 1 u 2U10 City of Tukwila BUILDING DJ Ii inlay 619.1 / SCALE: NO SCALE SEQUENCE OF OPERATION: A. GENERAL: 1. EQUIPMENT: a. STAND —ALONE PACKAGED SINGLE ZONE AIR CONDITIONING SYSTEM. b. SYSTEM PROVIDES HEATING, COOLING AND VENTILATION CT SCAN EXAM ROOM.. c. SYSTEM IS CONSTANT VOLUME 2. SYSTEM IS CONTROLLED THROUGH PACKAGED FACTORY CONTROLS. B. SYSTEM START /STOP: SYSTEM IS STARTED AND STOPPED BASED UPON A PROGRAMMABLE SCHEDULE; INITIALLY SET FOR 24/7 OPERATION. C. TEMPERATURE CONTROL: THE UNIT CONTROL PANEL SHALL UTILIZE THE UNIT ECONIMIZER, AND DX COIL TO MAINTAIN SPACE TEMPERATURE, INITIALLY 75 FOR COOLING AND 72 FOR HEATING. AN ALARM SHALL BE GENERATED WHENEVER TEMPERATURE RISES 5F ABOVE SETPOINT. RECEIVED OCT 13 2010 PERMIT CENTEF 1 kb, HP -1: SEQUENCE OF OPERATION M9.1 l SCALE: NO SCALE U U MECHANICAL DETAILS N REVISIONS Ps N c`, 4 6. co cci 442 us us - N N • ++ 4- 0 0 I-- Z w 2 w U 0 w 1— Z w 2 0_ w U 2 N TECTURE x u cc NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 JMR RKE 9 -10 -2010 9.1 10