Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M10-150 - WESTFIELD SOUTHCENTER MALL - GODIVA
GODIVA 555 SOUTHCENTER MALL M1O -150 Parcel No.: Address: City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT 9202470010 555 SOUTHCENTER MALL TUKW Project Name: GODIVA Permit Number: M10 -150 Issue Date: 11/02/2010 Permit Expires On: 05/01/2011 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 MICHAEL ATWOOD 9630 153 AV NE , REDMOND WA 98052 MATW OOD @MERITMCHANICAL. C OM Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: 425 883 -9224 Phone: 425 883 -9224 Expiration Date: 06/01/2011 DESCRIPTION OF WORK: REPLACE (1) CONDENSER UNIT, (1) AIR HANDLER, AND (1) REFRIGERATION PIPING WITH NEW (LIKE FOR LIKE CHANGE OUT). Value of Mechanical: $5,449.00 Type of Fire Protection: SPRINKLERS /AFA Permit Center Authorized Signature: Fees Collected: $257.06 International Mechanical Code Edition: 2009 Date: V I `d'--1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: \ ` 1 Date: 417.11,p145 Print Name: 1111 ( 1#}li1 A-71,,43 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10-150 Printed: 11 -02 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 555 SOUTHCENTER MALL TUKW Suite No: Tenant: GODIVA PERMIT CONDITIONS Permit Number: M10 -150 Status: ISSUED Applied Date: 10/19/2010 Issue Date: 11/02/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10-150 Printed: 11 -02 -2010 • City of Tukwila y \2 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: 14116,44141 ' I LlW9 Date: 11/211416 doc: Cond -10/06 M10-150 Printed: 11 -02 -2010 CITY OF TUKWIL, Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us Allot Mechanical Permit No. M , 0 ' 1 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITI ()CATION King Co Assessor's Tax No.: (120 21 '1.) U t 0 Site Address: SouthcenterJ6 AAA Suite Number: 1,020 Floor: New Tenant: ❑ Yes ❑ .. No Tenant Name: Godiva 341 Property Owners Name: Westfield Property Tax Dept. Mailing Address: City State Zip CONTACT PERSON - Who do ev conta when your permit,' is ready to be issued Name: Michael Atwood Day Telephone: (425) 883 -9224 Mailing Address: 9630 153rd Ave NE Redmond WA 98052 City Fax Number: E -Mail Address: matwood @meritmechanical.com State (425) 867 -0962 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Merit Mechanical, Inc. Mailing Address: 9630 153rd Ave NE Redmond WA 98052 Contact Person: Same as above E -Mail Address: Contractor Registration Number: MERITM1163CM City Day Telephone: Fax Number: Expiration Date: 06/01/2011 State Zip ARCHITECT OF RECORD - Alt plans must be wet stamped by Architect ol` Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD Alt plans must be wet stamped by Engineer a Company Name: Mailing Address: Contact Person: E -Mail Address: H:AApplicalions 'Forms- Applications On LinoA2009 Applications \1 -2000 - Mechanical Permit Applicntion.doc Rev iscd: 1 -2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ 5,449 Scope of Work (please provide detailed information): Replace (1) existing Condenser Unit, (1) Air Handler and (1) Refrigeration Piping with new - Like for Like change out Use: Residential: New Commercial: New Replacement Replacement Fuel Type: Electric ® Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty 1 Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator -- Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm /Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR HORIZ 1 AGENT: Signature: Print Name: 11 �1 t nom 411 -70-b Mailing Address: q(0& J ' 4 ulT /j/'r Ln b iA tI nip t,4__ Date: icV / '7.0t ) Day Telephone: ( " 7SV3 G�7 Z(/ X /Zio< 1 uS7 �r City State Date Application Accepted: 1 V‘ / r) Date Application Expires: 04 ((C1 L ( ( Staff Initials: C/ i. E!: ApplicationsWonns- Applications On Line \2009 Application M -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Gity of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SET RECEIPT Copy Reprinted on 10 -19 =2010 at 10 :48:05 10/19/2010 RECEIPT NO: R10 -02105 Initials: JEM User ID: 1165 Payee: MERIT MECHANICAL, INC. Payment Date: 10/19/2010 Total Payment: 372.56 SET ID: 1019 SET NAME: Temporary Set SET TRANSACTIONS: Set Member EL10 -0832 M10 =150 TOTAL: Amount 115.50 257.06 257.06 TRANSACTION LIST: Type Method Description Amount Payment Check 24322 372.56 TOTAL: 372.56 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.102.00.0 000.345.830 115.50 205.65 51.41 TOTAL: 372.56 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 = 431 =3670 • Fax: 206 - 431 -3665 INSPECTION RECORD Retain a copy with permit INSPECTIOD►"NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION PI- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206).431 -3670 Permit Inspection Request Line (206) 431 -2451 AID 4O Projec .- l�/ �AA co U u r V (�-1� Type of I spectjiionii: 44� )) , Ank-L Ak C Cam\ Address. 5 Sc r # Date Called: Special Instructions: 0 i 1.11 ^vf / Date Wanted: / ( -< / '�— '` '`° vpm Re quester: Phone No: is -44 - (C7 7 Approved per applicable codes. a Corrections required prior to approval. 1 COMMENTS: (ff 5^S M Ins , ector: r • Fi REINSPECTION FEE R QUIRED:'Prio to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t Date: INSPECTION RECORD Retain a copy with permit a— INSPECTION NO. PERMIT NO. '-- CITY OF TUKWILA• BUI.L-DING DIVISION' 6300 Southcenter Blvd., #100, Tukwila. I IA 98188 • (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: • • • 6, d IONN Of Type of Ins,pgection: Ref' et.ires,Ah ,/ i Address: S.'SS /),4d[. Date Called: • i• Special Instructions: . . - • Date Wanted: . // — 12 — ! 1 p.m. Requester: Phone No: • A/2. ate'- Al;/. S ^/A 7 41J) Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: r 4 J e 41J) ,,,,.,tA MekiX `r-z) Lik-8eA ite.W.41 : R /.....)_T A � -- _r j' -A A rI©_. - R- -- �j - - - - -- -- -- InspegEor: Date: n REINSPECTION FEEREQUIRED; Prior to next inspection.. fee must be . paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. P CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 F-- Project:' Typel qf Inspection: zot9_0- MI Address: '.!5 S 5 f)''3ht LL_ Date Called: Special Instructions: N 8.75 — o Z Date Wanted: .// •-- ✓2 —/ ei CP P.m. Requester: Phone No: 492 -DVS— /0 75, • Approved per applicable codes. El Corrections required prior to approval • COMMENTS: Inspect Date: 11 r RVINSPECTION FEE REQUIRED. Prior to Text inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. IR IT COORD CO PI`S PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -150 DATE: 10/19/10 PROJECT NAME: GODIVA SITE ADDRESS: 555 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: vv ` Q1 �If B uildin !vision IJ`YrFire Prevention WI Public Works Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Y.1 Comments: Incomplete ❑ DUE DATE: 10/21/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Building Please Route 14 REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 11/18/10 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MERIT MECHANICAL INC UBI No. 600517946 Phone 4258839224 Status Active Address Po Box 2109 License No. MERITMI163CM Suite /Apt. License Type Construction Contractor City Redmond Effective Date 2/14/1984 State WA Expiration Date 6/1/2011 Zip 980732109 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ciated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUTOMMC044QH AUTOMATED MECH CONTROLS INC Construction Contractor General Unused 11/8/1996 6/1/2010 Expired Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V President 02/14/1984 Bond Amount KIRKWOOD, JOAN M Secretary 02/27/2006 08358695 FRICKBERG, WILLIAM MICHAEL Vice President 02/27/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 FIDELITY Et DEPOSIT CO OF MD 08358695 02/01/2010 Until Cancelled $12,000.00 01/20/2010 9 ARCH INS CO SU1041124 02/01/2009 Until Cancelled 02/01/2010 $12,000.00 01/12/2009 8 TRAVELERS CAS & SURETY CO 081S103546895BCM 07/22/2001 Until Cancelled 02/01/2009 $12,000.00 03/07 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 LEXINGTON I INS 014180670 11/01/2010 11/01/2011 $2,000,000.00 10/29/2010 25 LEXINGTON I INS 049159165 11/01/2009 11/01/2010 $2,000,000.0011 /02/2009 24 CO INGTON INS 004052434 11 /01/2008 11/01/2009 $2,000,000.00 11/04/2008 23 ACE AMERICAN HD0G23734941 03/03/2008 03/03/2009 $2,000,000.0003 /10/2008 22 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2007 11/01/2008 $1,000,000.00 10/31/2007 21 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2005 11/01/2007 $1,000,000.00 10/18/2006 20 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2004 11/01/2005 $1,000,000.00 11/01/2004 https://fortress.wa.gov/lni/bbip/Print.aspx 11/02/2010 CONDENSING UNIT SCHEDULE TAG MAKE & MODEL DESCRIPTION COOLING, MBH REGRIG. PIPE OUTDOOR FAN SOUND COMPRESSOR ELECTRICAL WEIGHT REMARKS TOTAL SEER LIQ. SUCT. FLA DRIVE dBA TYPE RIA LRA VOLT PH MCA MOCP LBS CU -1 TECUMSEH AKA9461EXDXC REFRIGERATION UNIT 7500 - 1/2 3/8 0.70 DIRECT 50 - 5.3 31 208/230 1 7.3 15 129 1, 2, 3 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. 2. LOW /HI PRESS SWITCH, CRANKCASE HEATER. 3. OWNER PROVIDED, MERIT MECHANICAL INSTALL AIR HANDLER SCHEDULE TAG MAKE & MODEL DESCRIPTION FAN ELECTRICAL WEIGHT REMARKS CFM ESP RPM VOLT PH FLA LBS AH -1 PEERLESS PLP 750 AIR HANDLER UNIT 1200 - - 115 1 1.50 55 1, 2, 3 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. 2. OWNER PROVIDED, MERIT MECHANICAL INSTALL 3. SECONDARY DRAIN PAN. GENERAL NOTES 1. FIELD VERIFY UNIT LOCATIONS, DROPS, AND POSmONS. 2. ALL LINE VOLTAGE BY ELECTRICIAN. 3. 3/4" PVC CONDENSATE DRAIN WITH TRAP DISCHARGED ON SPLASH BLOCKS. USE COPPER PIPING FOR ABOVE HARD UD CEILING. 4. PROJECT MANAGER TO VERIFY LENGTH OF REFRIGERATION PIPING FOR UNE SIZES AND TRAPS AS PER MANUFACTURERS REQUIREMENTS. 5. HVAC SYSTEM IS DESIGNED PER 2006 WSEC, IBC, AND IMC. d A a 4 Nordstrom LOCATION OF WORK KEY PLAN SCALE: NONE SCOPE OF WORK 1. REPLACE 1 EXISTING CONDENSING UNIT WITH NEW. 2. REPLACE 1 EXISTING AIR HANDLER UNIT WITH NEW. 3. REPLACE EXISTING REFRIGERANT PIPING WITH NEW. macy s VICINITY MAP zoo Ott 4 seafood City Sears 0 —;A 4 a A.d A 1 JCPenny Il i) alckitq CJr. Strander. Blvd Southcenter TvlaII Southcenter Mali Southcenter w1sjI LEGAL DESCRIPTION TAX PARCEL NUMBER: 920247 -0010 SOUTHCENTER LLC BSIP (AKA NEW PARCEL A TUKWILA BSIP f108 -033 REC 120081106000242) LESS RD PER DEED 20090720001730 BUILDING INFORMATION ZONING: CONSTRUCTION TYPE OCCUPANCY TYPE TUC SHOPPING CENTER d OWNER WESTFIELD PROPERTY TAX DEPT FILE COPY evt Permit No M Pa' I Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize I'm violation of any adopted code or ordinance. Receipt of approved Field Co and conditions Is acknowledged: B y Date: 'tz,j1If1 WEST ELEVATION SCALE: 1/16" = 1' - 0" d d A d A n AO d 44 d ' . City Of TbIkwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: (. Mrichenboal fritectricas umbin9 Gas Pip1n City of Tukwila WADING DIVISION, COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE ENERGEY CODE (WSEC) SECTION 1416.1 (2006 EDmON) AN OPERATION MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.2 (2006 EDmON) ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 1416.2.2. (2006 EDmON) HVAC CONTROL SYSTEM SHALL BE ittiitD, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND COMPLETE REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2 AND 1416.2.5. (2006 EDmON) ABBREVIATIONS ABV. A.D. A.P. A.F.F. AH BF BOT CIP CLG CD CG CTG CONC. CONN. CFM DIFF. DIA. DN DWG. DB EA. ENT. EAT EWT EQUIP E(H ESP FLR FT. FPM FUT. GALV. GR. HWG HWTG HT. HP HWS HWR ABOVE ACCESS DOOR ACCESS PANEL ABOVE FINISHED FLOOR AIR HANDLING UNIT BELOW FLOOR BOTTOM CAST IN PLACE CEILING CEILING DIFFUSER CEILING GRILLE CEILING TRANSFER GRILLE CONCRETE CONNECTION CUBIC FEET PER MINUTE DIFFUSER DIANEEER DOWN DRAWING DRY BULB EACH ENTERING ENTERING AIR TEMPERATURE ENTERING WATER TEMPERATURE EQUIPMENT EXHAUST EXTERNAL STATIC PRESSURE FLOOR FOOT or FEET FEET PER MINUTE FUTURE GALVANIZE GRILLE HIGH WALL GRILLE HIGH WALL TRANSFER GRILLE HEIGHT HORSEPOWER HOT WATER SUPPLY HOT WATER RETURN ID INSIDE DIAMETER /DIMENSION IE INVERT ELEVATION IN. WG INCHES W.G. UN. DIFF. LINEAR DIFFUSER UN. FT. LINEAR FEET /FOOT LWG LOW WALL GRILLE LWR LOW WALL REGISTER MAX. MAXIMUM MBH 1000 BRITISH THERMAL UNITS MIN. MINIMUM MOT. DPR. MOTORIZED DAMPER MTD MOUNTED N.C. NORMALLY CLOSED N.O. NORMALLY OPEN OSA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER /DIMENSION PCF POUNDS PR CUBIC FOOT POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE RPBP REDUCED PRESSURE BACKFLOW PREVENTOR RFA RELIEF AIR REG. REGISTER REQ'D REQUIRED RA RETURN AIR SQ. FT. SQUARE FEET SA SUPPLY AIR S.L SOUND UNED TDH TOTAL DYNAMIC HEAD TG TRANSFER GRILLE TOT TOTAL TYP TYPICAL VTR VENT THROUGH ROOF WB WET BULB WG WATER GAUGE W/ WITH W/O Wm -OUT REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal m! may include additional plan review fees. DUCTWORK — LEGEND 0 0 ►Mo R - 100 S - 100 E - 100 - - -- SLSM FC I SFD T 1 VD E. MD VD MIN. 3' f AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR ROUND DUCT SYMBOL RETURN AIR; NUMBER INDICATES CFM QUANTITY SUPPLY AIR; NUMBER INDICATES CFM QUANTITY EXHAUST AIR; NUMBER INDICATES CFM QUANTITY SOUND LINED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION SMOKE /FIRE DAMPER ARE DAMPER VOLUME DAMPER MOTORIZED DAMPER TURNING VANES ROUND TO ROUND 45 FITTING SQUARE TO SC,,')RE 45' FITTING SQUARE TO ROUND 45' FITTING 45' F1111NG FOR DUCTWORK GENERAL LEGEND L_ _ _ —1 NEW EQUIPMENT, DUCTWORK, AND GRILLES EXISTING EQUIPMENT, DUCTWORK, AND GRILLES DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN, REVISION CLOUD & CHRONOLOGICAL NUMBER DETAIL REFERENCE OUTLINE REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 7 2010 AS City of Tukwila vAL BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 19 2010 PERMIT CENTER MOQ COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 0 0 309 SOUTHCENTER BLVD SPACE TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX 4(42 ) 8867?0962 LICENSE: MERITMI 1 63CM REVISIONS 1. ISSUED FOR PERMIT 10 -11 -10 DESIGNED VTD CHECKED AEA DATE 09 -29 -10 JOB NUMBER 810347 BXeET COVER SHEET SHEET NUMBER M0.1 1 —OF -3 NORDSTROM ESPRESSO BAR RISER � J TRASH AI TALBOTS ELEC BEN BRIDGE JEWELERS (EX: PARFUMIE) THE PICTURE PEOPLE ALLEY KAT VICTORIAS SECRET THE LIMITED BROW ART MAUI CREATIONS LJ 0 1- (f) 0 (J) PREMIER SKINCARE n- LJ Q LJ 0 Z VERIZON WIRELESS r T ELEC Z --� MADE IN WASHINGTON SPENCER GIFTS S BATH & BODY WORKS r TRASH -V Fie � PRETZE i1 0 LJ CC 0 0 0 X I_J (I ELEC GODIVA W ELEC CONCIERGE WC OFFICE SEATTLE TEAM SHOP HVAC PARTIAL 1 ST FLOOR PLAN SCALE: 1/16" = 1' — 0" rJ I-1 (0 T EXIST'G ENLARGED FLOOR PLAN SCALE 1/8" = 1' - OR REVIEWED FOR— CODE COMPLIANCE APPMWED OCT 2 7 201U City of Tukwila BUILDING DIVISION CITY OF TUKWILA OCT ' 19 2010 PERMIT CENTER COPYRIGHT NOTICE • THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. O N O 309 SOUTHCENTER BLVD SPACE TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX (425)8867 20962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERM' 10 -11 -10 DESIGNED VTD CHECKED AEA DATE 09 -29 -10 JOB NUMBER 810347 SHEET TITLE HVAC PLAN SHEET NUMBER M2.0 2 -OF -3 PROPS :LINE PROPERTY LINE 500' PLUS 1 r 1 1 1 /\ / / / / / EQUIPMENT PAD / / / / MIL AMIN / 1 NR ON OR LEVEL ROOF ACCESS / i / / / / • • .. L .. PROPERTY LINE HVAC PARTIAL ROOF PLAN SCALE: 1/16' = 1' - 0' ROOF WALK WAY 1300' PLUS EQUIPMENT PAD 7 NCREVIEWED D FOR APPRAVEp OCT 2 7 2010 PROPERTY LINE City of Tukwila BUILDING DIVISION RECEIVED CITY OF TU (WILA OCT 1.92010 PERMIT CENTER ,COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 309 SOUTHCENTER BLVD SPACE TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX4(42 ) 8867?0962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERMIT 10 -11 -10 DESIGNED VTD CHECKED AEA DATE 09 -29 -10 JOB NUMBER 810347 SHEET TITLE ROOF PLAN SHEET NUMBER M2.1 3 -OF -3 1 - -- EQUIPME AT PAD AM v®- -- REFER UP . THROUGH ROOF / / / / • • .. L .. PROPERTY LINE HVAC PARTIAL ROOF PLAN SCALE: 1/16' = 1' - 0' ROOF WALK WAY 1300' PLUS EQUIPMENT PAD 7 NCREVIEWED D FOR APPRAVEp OCT 2 7 2010 PROPERTY LINE City of Tukwila BUILDING DIVISION RECEIVED CITY OF TU (WILA OCT 1.92010 PERMIT CENTER ,COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 309 SOUTHCENTER BLVD SPACE TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX4(42 ) 8867?0962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERMIT 10 -11 -10 DESIGNED VTD CHECKED AEA DATE 09 -29 -10 JOB NUMBER 810347 SHEET TITLE ROOF PLAN SHEET NUMBER M2.1 3 -OF -3