HomeMy WebLinkAboutPermit M10-152 - NORDSTROMS - CHILD CARENORDSTROMS
CHILD CARE
100 SOUTHCENTER MALL
M10 -152
City ofaukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
MECHANICAL PERMIT
Parcel No.: 9202470010
Address: 100 SOUTHCENTER MALL TUKW
Project Name: NORDSTROMS CHILD CARE
Permit Number:
Issue Date:
Permit Expires On:
M10 -152
11/05/2010
05/04/2011
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name:
Address:
Email:
KAREN GEORGE
9322 14 AV S , SEATTLE WA 98108
KGEORGE@PSFMECH.COM
Contractor:
Name: PSF MECHANICAL, INC.
Address: 9322 14TH AVENUE SOUTH , SEATTLE, WA 98108
Contractor License No: PSFMEI *090NZ
Phone: 206 812 -7678
Phone: 206 764 -9663
Expiration Date: 10/03/2011
DESCRIPTION OF WORK:
MODIFY EXISTING MECHANICAL FOR SMALL TENANT REMODEL. REMOVE (1) FAN TERMINAL
BOX AND REPLACE WITH NEW.
Value of Mechanical: $10,000.00
Type of Fire Protection: SPRINKLERS /AFA
Permit Center Authorized Signature
I hereby certify that I have read and
governing this work will be complie
Fees Collected: $369.06
International Mechanical Code Edition: 2009
Date: D(l
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not pre
construction or the performance of work.
back of this permit.
Signature:
Print Name: ( ! ;l' kt E{L
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
Date: (/ t2 /
doc: IMC -4/10
M10 -152 Printed: 01 -12 -2011
• •
PERMIT CONDITIONS
Permit No. M10-152
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M10 -152 Printed: 01 -12 -2011
City "Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 -431 -2451
Web site: http: / /www.ci.tukwila.wa.us
MECHANICAL PERMIT
Parcel No.: 9202470010
Address: 100 SOUTHCENTER MALL TUKW
Project Name: NORDSTROMS CHILD CARE
Permit Number: M10 -152
Issue Date: 11/05/2010
Permit Expires On: 05/04/2011
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name: KAREN GEORGE
Address: 9322 14 AV S , SEATTLE WA 98108
Email: KGEORGE@PSFMECH.COM
Contractor:
Name: PSF MECHANICAL, INC.
Address: 9322 14TH AVENUE SOUTH , SEATTLE, WA 98108
Contractor License No: PSFMEI *090NZ
Phone: 206 812 -7678
Phone: 206 764 -9663
Expiration Date: 10/03/2011
DESCRIPTION OF WORK:
MODIFY EXISTING MECHANICAL FOR SMALL TENANT REMODEL. REMOVE (1) FAN TERMINAL
BOX AND REPLACE WITH NEW.
Value of Mechanical: $10,000.00
Type of Fire Protection: SPRINKLERS /AFA
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
x.
wit
Fees Collected: $306.06
International Mechanical Code Edition: 2009
Date: I I Gc I d
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I authorized to sign and obtain this mechanical permit.
Signature:
Print Name:
Date: /7 } :— /7)
This permit shall become null and void if the work is no commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M10-152 Printed: 11 -05 -2010
• •
wqs City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 9202470010
Address:
Suite No:
Tenant:
100 SOUTHCENTER MALL TUKW
NORDSTROMS CHILD CARE
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M10 -152
ISSUED
10/22/2010
11/05/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
doc: Cond -10/06
M10-152 Printed: 11 -05 -2010
•
�J�.`N1LA wq� City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
ry e_
Date: // / V
doc: Cond -10/06
M10-152 Printed: 11 -05 -2010
•
h
•
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
ff.
Mechanical Permit No.
Project No.
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
King Co Assessor's Tax No.: 9202470010
Site Address: 100 Southcenter Mall
Tenant Name:
Nordstrom Inc.
Suite Number:
Property Owners Name: Westfield Property
Mailing Address: PO Box 130940
New Tenant:
Floor:
❑ Yes
Carlsbad
CA
City
State
2
.. No
92013
Zip
CONTACT PERSON = who do we contact when your permit is ready to be issued
Name: Karen George
Mailing Address: 9322 14th Ave S
Day Telephone: (206) 812 -7678
Seattle WA
98108
E -Mail Address: kgeorge @psfinech.com
City State
Fax Number: (206) 812 -7679
Zip
MECHANICAL CONTRACTOR.INFORMATION
Company Name: PSF Mechanical, Inc.
Mailing Address: 9322 14th Ave S
Seattle
WA
98108
Contact Person: Wayne Champagne
E -Mail Address: wchampagne@psfinech.com
Contractor Registration Number: PSFMEI *090NZ
City State
Day Telephone: (206) 764 -9663
Fax Number: (206) 762 -8381
Expiration Date: 10/03/2011
Zip
ARCHITECT OF RECORD — All plans must be stamped by architect of record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be stamped by engineer of record
Company Name: PSF Mechanical, Inc.
Mailing Address: 9322 14th Ave S
Seattle
WA
98108
Contact Person: Lawrence Palmer
E -Mail Address: Ipalmer @psfinech.com
H:Wpplications \Forms - Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc
Revised: 7 -2010
bh
City State
Day Telephone: (206) 764 -9663
Fax Number: (206) 762 -8381
Zip
Page 1 of 2
• •
Valuation of project (contractor's bid price): $ 10,000.00
Scope of work (please provide detailed information): Modify existing mechanical for small tenant remodel.
Removing (1) Fan terminal box & replacing with new.
These drawings were submitted with the general permit intake for Callison Architecture. Permit # D10 -278
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric m
Gas ❑ Other:
Indicate type of mechanical work being installed and the quanfty below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Bioler /Compressor
Qty
furnace <100k btu
air handling unit
>10,000 cfm
fire damper
0 -3 hp /100,000 btu
furnace >100k btu
evaporator cooler
diffuser
3 -15 hp /500,000 btu
floor furnace
ventilation fan connected
to single duct
thermostat
15 -30 hp /1,000,000
btu
suspended/wall /floor
mounted heater
ventilation system
wood/gas stove
30 -50 hp /1,750,000
btu
appliance vent
hood and duct
emergency
generator
50+ hp /1,750,000 btu
repair or addition to
heat/refrig/cooling system
Incinerator — domestic
other mechanical
equipment
air handling unit <10,000
cfm
incinerator— comm/ind
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 international building code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZE AGENT:
Signature:�o�v(
Date: 40- 0707—/ 7
Print Name: Karen George Day Telephone: (206) 812 -7678
Mailing Address: 9322 14th Ave S Seattle WA 98108
IDate Application Accepted: 10
City
State Zip
22
LD
Date Application Expires: C,L
2 tf
Staff Initials:
H:'Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc
Revised 7.2010
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
Parcel No.: 9202470010
Address:
Suite No:
Applicant: NORDSTROMS CHILD CARE
100 SOUTHCENTER MALL TUKW
RECEIPT
Permit Number:
Status:
Applied Date:
Issue Date:
M10 -152
ISSUED
10/22/2010
11/05/2010
Receipt No.:
Initials:
User ID:
Payee:
R10 -02532
JEM
1165
Payment Amount: $63.00
Payment Date: 12/17/2010 04:07 PM
Balance: $0.00
PSF MECHANICAL, INC.
TRANSACTION LIST:
Type Method
Descriptio Amount
Payment Check
Authorization No.
014545 63.00
ACCOUNT ITEM LIST:
Description Account Code
Current Pmts
MECHANICAL - NONRES 000.322.102.00.00
Total: $63.00
63.00
doc: Receiot -06
Printed: 12 -17 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
ParcelNo.: 9202470010 Permit Number: M10 -152
Address: 100 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 10/22/2010
Applicant: NORDSTROMS CHILD CARE Issue Date:
Receipt No.: R10 -02142
Payment Amount: $306.06
Initials: JEM Payment Date: 10/22/2010 10:37 AM
User ID: 1165 Balance: $0.00
Payee: PSF MECHANICAL, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 014510 306.06
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 244.85
000.345.830 61.21
Total: $306.06
doc: Receiot -06 Printed: 10 -22 -2010
•
•
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT Na
CITY OF TUKWILA BUILDING DIVISION 't
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431!`3670
Permit Inspection Request Line (206) 431 -2451
Mt & -(52
Proj cc . A
ar 010i1-44,15 Cld at
Type of Inspection:
Address:
Date Called:
Special Instructions:
'
Date Wanted: -.,
1 I3 --If
p.m.
Requester:
Phone No:
2.40(o -13O 9_t -?
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
• pg, eel egg.", lele/A:V1/
Date:
1t�J
CTION FEE REQUIFED. Prior, b next inspection. fee must be
6300 Southcenter B d.. Suite 00. Call to schedule reinspection.
/41 /o -
�sZ
FIT AIR OUTLET TEST REPORT
or''
Project Nordstrom child
Proje t #
System FC -3
Box Type Trane Split system
BOX I.D.:
FC -3
MODEL #:
twh060p150a0
OUTLET
AIRFLOW CFM (Us)
% OF
DESIGN
SERIAL #:
c47480904
AREA SERVED
NO.
TYPE
SIZE
DESIGN
PRELIM.
FINAL
stroage
1
supply
12x12
250
440
370
148%
storage
2
supply
12x12
250
440
380
152%
child care
3
supply
12x12
300
520
380
127%
child care
4
supply
12x12
300
400
470
157%
storage
5
supply
12x12
250
240
410
164%
6
7
8
9
10
_
INLET SIZE :
F/C :
BOX TOTAL
1350
2040
2010
149%
HEAT K.W.:
AMPS :
PRIMARY MAX
FAN SPEED :
Delta T :
PRIMARY MIN
FAN CFM
BOX I.D. :
MODEL #:
OUTLET
AIRFLOW CFM (Us)
% OF
DESIGN
SERIAL #:
AREA SERVED
NO.
TYPE
SIZE
DESIGN
PRELIM.
FINAL
1
2
3
4
5
6
7
8
9
10
INLET SIZE :
F/C :
BOX TOTAL
HEAT K.W.:
AMPS :
PRIMARY MAX
FAN SPEED :
Delta T :
PRIMARY MIN
FAN CFM
REMARKS
(1) Wide Open Path
Found 5 ton split system in lieu of FIT box. Recalculated proportional values based on initial total reading of
2040 cfm. Proportionally balanced as shown.
Date:
Readings by:
ettitill WON WV
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -152 DATE: 12 -15 -10
PROJECT NAME: NORDSTROMS CHILD CARE
SITE ADDRESS: 100 SOUTHCENTER MALL
Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # X Revision # 1 After Permit Issued
DEPARTMENTS:
PA.
ding �lvision� �`1�
Public Works ❑
AA N A-
e Prevention
Structural n
Planning Division
Permit Coordinator
n
•
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -16 -10
Complete
Incomplete
Not Applicable
n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required
nNo further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 01-13 -11
Approved IX Approved with Conditions ❑ Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
• lERACT D COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -152 DATE: 10/22/10
PROJECT NAME: NORDSTROMS CHILD CARE
SITE ADDRESS: 100 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS: �' A`L�10\ B I ing Division Fire Prevenitvid
❑ Structural ❑
Public Works
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 10/26/10
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Building
Please Route Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 11/23/10
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28-02
PROJECT NAME: Doris. „Ais_ C L
SITE ADDRESS: kPO T'o i
1
PERMIT NO: IA I n'
ORIGINAL ISSUE DATE: -1
REVISION LOG
REVISION
NO.
DATE'RECEIVED
STAFF
INITIALS
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
k).--AT— 0
(AL
\ Ant 10
Received by:
.
Summary of Revision: pe c,.e Sc,
O uldrk, 4 f ,e c-1..; •may
.# �,� ►,�
Received by: I � c j
(3- E or a r
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE
STAFF
.INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
City of Tukwila !
REVISION
SUBMITTAL
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Web site: http. / /www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 12/xx./10 Plan Check/Permit Number: --D44-2q'8 Vt (0— (S a.,
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
• Revision # 1 after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Nordstrom Southcenter -Child Area
Project Address: 100 Southcenter Mall
Contact Person: Wayne Champagne
Phone Number: (206) 227 -8171
Summary of Revision:
Original design was installing a new terminal box and duct distribution.
New design is reusing the existing terminal box and duct distribution and relocating supply grills
RECEIVED
env OF TUKIMLA
IDEC115.2010
PERMIT
Sheet Number(s): M -001 and M -121
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
tq Entered in Permits Plus on CO
H:\Applications\Forrns- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc
Created: 8 -13 -2004
Revised: 7 -2010
`RJ__
Contractors or Tradespeople Peter Friendly Page
1
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name P S F MECHANICAL
INC
UBI No. 601318369
Phone 2067649663 Status Active
Address 9322 14Th Ave 5 License No. PSFMEI'090NZ
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 8/9/1991
State WA Expiration 10/3/2011
Date
Zip 98108 Suspend Date
County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig
(Hvac /R)
Business Type Corporation Specialty 2 Unused
Parent
Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
EDENN "225LKEDEN
NURSERIES
Construction
Contractor
General
Unused
6/12/1978
6/1/1986
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
BEARDSLEY, WARREN 5
Cancel Date
01/01/1980
Bond Amount
CRITCHLOW, JAMES D
4
01/01/1980
08973126
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
4
FIDELITY & DEPOSIT
CO OF MD
08973126
08/08/2009
Until Cancelled
$6,000.0007/10/2009
09/29/2010
3
HARTFORD FIRE INS
52BSBFA6327
08/08/2008
Until Cancelled
08/08/2009
$6,000.00
07/08/2008
2
FEDERAL INS CO
81241859
08/08/2001
08/08/2008
$6,000.0010/01/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
18
WAUSAU
UNDERWRITERS
INS. CO.
TBJZ91452741020
10/01/2010
10/01/2011
$1,000,000.00
09/29/2010
17
WAUSAU
BUSINESS INS
CO
TBJZ91452741029
10/01/2009
10/01/2010
$1,000,000.00
10/07/2009
16
WAUSAU
UNDERWRITERS
INS. CO.
TBJZ9145274109
10/01/2009
10/01/2010
$1,000,000.00
09/28/2009
15
TRAVELERS
PROPERTY CAS
INS CO
DTEC0527D0578TIL08
10/01/2008
10/01/2009
$1,000,000.0009
/23/2008
https : / /fortre s s. wa. gov /l ni/bbip /Print. aspx
11/05/2010
SYMBOLS & ABBREVIATIONS
SYMBOL ABBREV. DESCRIPTION
SYMBOL ABBREV. DESCRIPTION
AREA SERVED
--
0
A.C. AIR CONDITIONLNC, UNIT
A.D. AIR DOOR
A.F.F. ABOVE FINISHED FLOOR
KW
AC AC 71 MECHANICAL EQUIPMENT TAG
FLA
STAGES
NOM. NOMINAL
/D../X/ O.B.D. OPPOSED BLADE DAMPER
8.5 ORIFICE SIZE (INCHES)
O.A. OUTSIDE AIR
OV. OVAL
/// P.B.D. PARALLEL BLADE DAMPER
P.O.G. POINT OF CONNECTION
REMARKS
B.D.D. BACKDRAFT DAMPER
B.S. BIRD SCREEN
B.O.G. BOTTOM OF GRILLE
B.O.D. BOTTOM OF DUCT
BT B.T. BYPASS TIMER
4. CENTER LINE
CUH CABINET UNIT HEATER
DIA. DIAMETER
D.S. DISCONNECT SWITCH
D.T.S. DUCT TEMPERATURE SENSOR
-----*- R
RE
R. RELOCATE
R.A. RETURN AIR
R.B. REBALANCE
R.A.G. RETURN MR GRILLE
R.V.D. REMOTE VOLUME DAMPER
li RETURN DUCT DOWN
1350
�.`
277V11PH
1 C D.G. DOOR GRILLE
Q DRAWING NOTE
1871,.,
SERVED BY FIT 2 -12
EDC 2.12
11 RETURN DUCT UP
�- D - D DUCT DROP IN DIRECTION OF ARROW
2ND
750
1.0
277V11PH
®, SIDE INLET CAN
�- R . R DUCT RISE IN DIRECTION OF ARROW
DN. DOWN
E.G.H. ELECTRIC CEILING HEATER
E.D.C. ELECTRIC DUCT COIL
E.F.C. ELECTRIC FAN COIL
E.U.H. ELECTRIC UNIT HEATER
E.C. ELECTRICAL CONTRACTOR
G ELEVATION
EXIST. EXISTING
E.A. EXHAUST AIR
E.F. EXHAUST FAN
EXT. EXTERIOR OR EXTERNAL
SERVED BY FIT 2 -13
SD 1
S.D. SMOKE DETECTOR
a
0
S.
DMPR. SMOKE DAMPER
S.P.F. SMOKE PURGE FAN
S.S.S.C. SOLID STATE SPEED CONTROL
Jr S.L. SOUND LINING
SPLITTER DAMPER
SP. DMPR.
RECT. - ROUND
SQUARE TO ROUND DUCT TRANSITION
S/S START /STOP
SP
STATIC PRESSURE SENSOR
1></N
S.A. SUPPLY AIR
1‘/C) SUPPLY DUCT DOWN
4 1 SUPPLY DUCT UP
'z`
EXTR. EXTRACTOR
'rte
F.I.T. FAN INDUCTION TERMINAL
FD F.D FIRE DAMPER'
OS
®
OT
):171:2"‘"":
AV
SW. SWITCH
T.C. TEMPERATURE CONTROL
T.S. TEMPERATURE SENSOR
TSTAT. THERMOSTAT
TOP INLET LAY -IN
T.O.D. TOP OF DUCT
T.F. TRANSFER FAN
T.V. TURNING VANES
U.D. UNDERCUT DOOR
V.A.V. VARIABLE MR VOLUME TERMINAL
FSD F.S.D. FIREISMOKE DAMPER
F.O.B. FLAT ON BOTTOM
F.O.T. FLAT ON TOP
11 I
1 I
1 I[Jr F.C. FLEXIBLE CONNECTION
•
G.C. GENERAL CONTRACTOR
DIFFUSER TYPE
GRILLE, REGISTER,-OR
A 8x8 NECK SIZE (INCHES)
200 AIR QUANTITY (CFM)
GIRD I.D. NUMBER
H.P. HEAT PUMP OR HORSEPOWER
INT. INTERLOCK
M.U.A. MAKE -UP AIR
M.U.F. MAKE -UP AIR FAN
M.C. MECHANICAL CONTRACTOR
V.D. VOLUME DAMPER
CC
C--N
T
O
WIRE GUARD COVER OVER TEMPERATURE SENSOR
WIRE GUARD COVER OVER THERMOSTAT
1
MOTORIZED DAMPER
MD
M.D.
GENERAL NOTES
1. ALL DUCTWORK SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES: CODES,
RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF TUKWILA, AND THE 2006 INTERNATIONAL MECHANICAL CODE.
2. RECTANGULAR AND ROUND DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH SOUNDLINING OR EXTERNAL INSULATION WRAP AS
INDICATED IN NOTE 4 UNLESS OTHERWISE NOTED.
3. FLEXIBLE DUCTWORK SHALL BE CLASS 1 CONFORMING TO U.L. STANDARD 181 AS REQUIRED BY LOCAL CODE OR AGREEMENT.
4. DUCTWORK SHALL BE INSULATED PER THE TABLE BELOW
DUCTS REQUIRING INSULATION:
A. INDOOR, CONCEALED SUPPLY AND OUTDOOR AIR.
B. INDOOR, CONCEALED RETURN LOCATED IN NONCONDITIONED SPACE.
C. OUTDOOR, EXPOSED SUPPLY AND RETURN.
ITEMS NOT REQUIRING INSULATION:
A. METAL DUCTS WITH DUCT LINER OF SUFFICIENT THICKNESS TO COMPLY WITH LOCAL ENERGY CODE.
B. FACTORY- INSULATED FLEXIBLE DUCTS.
C. FLEXIBLE CONNECTORS.
D. VIBRATION - CONTROL DEVICES.
E. FACTORY - INSULATED ACCESS PANELS AND DOORS.
5. TAPE OR SEAL ALL JOINTS IN CONCEALED DUCTWORK SYSTEM
6. ALL CUTTING, PATCHING, FRAMING, FIRE SAFING, PAINTING, ROOF OPENING CURBS, ROOFING ETC,, REQUIRED TO INSTALL MECHANICAL
SYSTEM HEREIN SHALL BE BY GENERAL CONTRACTOR, INCLUDING ALL FLASHING, SEALING, FRAMING AND ROOFING ON SHEET METAL
DUCT ENCLOSURES.
7. MECHANICAL EQUIPMENT ACCESS PANELS IN FURRED ENCLOSURES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR.
8. POWER WRING AND CONNECTIONS TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. CONTROL WIRING AND LOW
VOLTAGE CONNECTION TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR.
9. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SHEET METAL.
10. ALL MEDIUM PRESSURE DUCT TO BE MANUFACTURED IN ACCORDANCE WITH SMACNA MEDIUM PRESSURE STANDARDS.
11. BUTTER ALL JOINTS AT SOUNDLINING IN MEDIUM PRESSURE DUCTWORK.
12. ALL MEDIUM PRESSURE DUCT TAKEOFF FITTINGS SHALL BE BOOT TEES UNLESS OTHERWISE NOTED.
13. INLET CONNECTIONS TO ALL MEDIUM PRESSURE TERMINAL UNITS SHALL HAVE BEAD AND CRIMP TO ASSURE POSITIVE FLEXIBLE DUCT
CONNECTION. MINIMUM FLEX DUCT LENGTH SHALL BE THREE FEET UNLESS RESTRICTED BY LOCAL CODE OR AGREEMENT.
14. ELEVATIONS SHOWN ON THESE DRAWINGS ARE INTENDED FOR DESIGN COORDINATION ONLY. REFER TO HVAC SHOP DRAWINGS FOR
EXACT ELEVATIONS AND DIMENSIONS.
15. CONTACTORS, MAGNETIC STARTERS AND DISCONNECT SWITCHES SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR,
UNLESS NOTED OTHERWISE.
16. DRAWINGS AND MANUALS SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY
CODE WITH SECTIONS 1416.
17. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH
SECTIONS 1416.2.3- 1416.2.6.3.
18. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE
WITH SECTIONS 1416.2 - 1416.2.3.
19. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE W /IBC, IMC & SMACNA SEISMIC STANDARDS.
20. PROVIDE PIPE INSULATION PER 14-6 WSEC.
21. PROVIDE 5 DEGREE DEADBAND W/ AUTO SETBACK PER WSEC.
22. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICAL SYSTEMS PER WSEC TABLE 14-4.
23. EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT.
24. DUCT INSULATION IS SHOWN WHERE REQUIRED BY CODE. INSULATION OUTSIDE OF SHELL AND CORE AREAS SHALL BE PROVIDED AS
PART OF THE TENANT IMPROVEMENT PROJECTS.
25. EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 °F WITHIN WHICH THE SUPPLY OF HEATING AND
COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM.
26. MOTORIZED DAMPERS WILL BE PROVIDED TO CLOSE AUTOMATICALLY WHEN IT'S RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE.
27. HEATING AND COOLING SYSTEMS SHALL HAVE OPTIMUM START CONTROLS.
28. AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO 100% OF THE DESIGN
SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING.
REBALANCE
EXISTING
SEPARATE PERMIT
REQUIRED FOR:
❑ Mechanical
L'�Electrical
Plumbing
Las Piping
i`y of Tukwila
Et ° _`'IS'J11 DIVISION
FILE COPY
Permit No
Plan review approval is subject to errors and � authorize
approval of construction documents does
lh violation of any adopted code or ordinance. Receipt
of approved Field Co • and conditions is + owledged:
By
Date: ,-)y-/V
- '""'""'"
City Of 'htkwHa
BUILDING DIVISION
M
REVISIONS
No changes shalt b e made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new p!an submittal
and may inc ude additional plan review fscs.
REVIEWED FOR
CODE COMPLIANCE
DEC 16 2U10
�S `1
City of Tukwila
BUILDING MINION
REVISION.N,01 __l
RECEIVED
DEC 15 2010
PERMIT CENTER
PARTIAL ELECTRIC DUCT HEATER SCHEDULE
MARK
MFR 1 MODEL
AREA SERVED
FLOOR
CFM
KW
POWER
FLA
STAGES
DUCT SIZ"w
REMARKS
EDC 2 -11
REDD -I / MODEL R
CHILDREN'S PLAY AREA
2ND
1350
3.5
277V11PH
12:6
1
1871,.,
SERVED BY FIT 2 -12
EDC 2.12
REDD -I I MODEL R
OFFICES
2ND
750
1.0
277V11PH
I 3.6
1
14712"
SERVED BY FIT 2 -13
PARTIAL FAN INDUCTION TERMINAL UNIT SCHEDULE
MARK
MFRJ MODEL
PSF / FAN INDUCTION
TERMINAL
PSF /FAN INDUCTION
TERMINAL
AREA SERVED
CHILD CARE 2D19, STORAGE 245
FAN CFM
1350
PRIMARY CFM
MAX MIN
1350
165
HP
(2) 1/3
FAN
SPEED
ELECTRIC HEATER
POWER KW POWER
D.S.
INCLUDED
INLET
SIZE
AC SYS.
CRITICAL ZONE RESET
EMCS FUNCTION
REMARKS
S/S
TC TOD GRP
VAR
277V/1 PH
AC-4
0
0
0
OFFICE 250
750
750
116
120V/1 PH
AC -4
0
0
0
PARTIAL DIFFUSER SCHEDULE
MARK
MFR/MODEL T
NOTES
DESCRIPTION
B
ANEMOSTAT 1 PRT
TITUS 1 PMC -DF
24X24 LAY -IN
S.A.
PERFORATED TEGULAR LAY -IN DIFFUSER
G
ANEMOSTAT 13PTD
T ITUS 1 PDR
„ „ , ,
24X24 LA VIN
R.A. 1 EXH.
PERFORATED TEGULAR LAY -IN RETURN OR EXHAUST
GRILLE'vVITH DUCT COLLAR
N
ANEMOSTATI S3HD
TITUS / 23RL
EXPOSED FASTENERS
R.A.,' EXH.
SURFACE MOUNT RETURN OR EXHAUST GRILLE
DRAWING SCHEDULE
DWG.
DESCRIPTION
M -001
HVAC SCHEDULES AND GENERAL NOTES
M -121
SECOND FLOOR HVAC PLANS - DEMO AND NEW
(.' -. 211T _ .
z
0
J
J
z
i
w
O
O z
0
m
M
0
M
CO
0
N
H
0.0 Q
o0
`C > o CO
to
> m
¢Qo)
au -m
!n N *iQ
ZO � M �N
o . a) U) I- IL
E 7nR '1n1 L'l1 ta
Ina 7R9 RlR9
E
0
7
0 a
ta
r .U)
1
..1 c
t9 }
O
1-az
V J
0
0
SOUT CENTER
WA 98188
210449.00
ISSUED / REVISED DATE
BID /PERMIT 10/11/10
BID SET 11/02/10
BID /PERMIT SCOPE
REDUCTION 12/09/10
HVAC SCHEDULES
AND GEMERAL MOTES
MOO1
}
PARTIAL SECOND FLOOR HVAC PLAN - DEMO
SCALE : 118 " =1' -0"
9 `,
/T Tl
/7 I \ / ‘c. \ ;.
X1
•
a c _
12)12 I 13
2O \
r "A:
2f;
r4 ti
-713-71 I rx 1 4'
! ) -5
711
I
-1�1 s 1
Ii
•rii- Tr
1- +11 _! 111
1 1
1 4 �I� g
10x4
120
iff
1-1-1
11
10x4 10x4
ft
Bxs
130
r .1
I
REVISION N0:1
HIO I52
REVIEWED FOR
C
ODE COMPLIANCE
PionnVE
DEC 162010
City of Tukwila
BUILDING DivI41GN
PARTIAL SECOND FLOOR HVAC PLAN - NEW
SCALE : 1i8 " =1'-0"
RECEIVED
DEC 15 2010
PERMIT CENTER
LEGEND
— DEMO
NEW DUC1' 0RK
O
O
0
O
0
m
O
Z U
0
ma 0
zl N
a CO
U
j
7 ;7,
0 co
x-- co
• 0.)
cm 0 4.-.=
� o �
o O I-
ca r
z
C 7fR '2n'.r Lta1•
F 7nR 7R7 A'R1
210449.00
ISSUED / REVISED DATE
BID /PERMIT 10/11/10
BID SET 11/02/10
BID /PERMIT SCOPE
REDUCTION 12/09/10
SECOND FLOOR HVAC
PLANS - DEMO AND NEW
Mw121
F
E
D
C
B
6
14
SYMBOLS & ABBREVIATIONS
SYMBOL ABBREV. DESCRIPTION
SYMBOL ABBREV. DESCRIPTION
MFRJ MODEL
W
o
A.C. AIR CONDITIONING UNIT
A.U. AIR DOOR
A.F.F. ABOVE FINISHED FLOOR
PRIMARY CFM
AC-XXX) EQUIPMENT TAG
MECHANICAL
Q
D.S.
INCLUDED
NOM. NOMINAL
/X/X/ O.B.D. OPPOSED BLADE DAMPER
8.5 ORIFICE SIZE (INCHES)
O.A. OUTSIDE AIR
OV. OVAL
/// P.B.D. PARALLEL BLADE DAMPER
_ „�,,
P.O.C. POINT OF CONNECTION
AC SYS.
B.D.D. BACKDRAFT DAMPER
B.S. BIRD SCREEN
B.O.G. BOTTOM OF GRILLE
B.O.D. BOTTOM OF DUCT
BT B.T. BYPASS TIMER
CENTER LINE
CUH CABINET UNIT HEATER
DIA. DIAMETER
D.S. DISCONNECT SWITCH
D.T.S. DUCT TEMPERATURE SENSOR
--"---e, R
RB
R. RELOCATE
R.A. RETURN AIR
R.B. REBALANCE
R.A.G. RETURN AIR GRILLE
R.V.D. REMOTE VOLUME DAMPER
MAX
D.G. DOOR GRILLE
0 DRAWING NOTE
SPEED
.���
`, ,) RETURN DUCT DOWN
POWER
SIS
I
® RETURN DUCT UP
f. D Jr D DUCT DROP IN DIRECTION OF ARROW
FIT 2 -12
TRANE / VSEF 1004SQ
CHILD CARE 2D19, STORAGE 245
920
►� '"'" SIDE INLET CAN
Jr____ j R DUCT RISE IN DIRECTION OF ARROW
DN. DOWN
E.C.H. ELECTRIC CEILING HEATER
E.D.C. ELECTRIC DUCT COIL
E.F.C. ELECTRIC FAN C01!
E.U.H. ELECTRIC UNIT HEATER
E.C. ELECTRICAL CONTRACTOR
ELEVATION
EXIST. EXISTING
E.A. EXHAUST AIR
E.F. EXHAUST FAN
EXT. EXTERIOR OR EXTERNAL
VAR
277V/1 PH
7.0
I SD {
YES
S.D. SMOKE DETECTOR
0
DMPR.
S. SMOKE DAMPER
S.P.F. SMOKE PURGE FAN
S.S.S.C. SOLID STATE SPEED CONTROL
t
S.L. SOUND LINING
-
1, 2, 4, 6
FIT 2 -13
SP. DMPR. SPLITTER DAMPER
RECT. ROUND
750
SQUARE TO ROUND DUCT TRANSITION
-
1
S/S START /STOP
SP
STATIC PRESSURE SENSOR
-
-
S.A. SUPPLY AIR
o
EXTR. EXTRACTOR
F.I.T. FAN INDUCTION TERMINAL
-
/\
SUPPLY DUCT DOWN
. )
® SUPPLY DUCT UP
Al
FD F.D FIRE DAMPER
0
6
Q
SW. SWITCH
T.C. TEMPERATURE CONTROL
T.S. TEMPERATURE SENSOR
T'STAT. THERMOSTAT
FSD F.S.D. FIRE /SMOKE DAMPER
F.O.B. FLAT ON BOTTOM
F.O.T. FLAT ON TOP
)2( TOP INLET LAY -IN
3
1111111 I F.C. FLEXIBLE CONNECTION
G.C. GENERAL CONTRACTOR
TYPE
T.O.D. TOP OF DUCT
T.F. TRANSFER FAN
i GRILLE, REGISTER, OR DIFFUSER
} T.V. TURNING VANES
A 8x8 NECK SIZE (INCHES)
200 AIR QUANTITY (CFM)_
GiRID I.D. NUMBER
H.P. HEAT PUMP OR HORSEPOWER
INT. INTERLOCK
M.U.A. MAKE -UP AIR
M.U.F. MAKE -UP AIR FAN
M.C. MECHANICAL CONTRACTOR
U.D. UNDERCUT DOOR
V.A.V. VARIABLE AIR VOLUME TERMINAL
tiltill V.D. VOLUME DAMPER
re
1 WIRE GUARD COVER OVER TEMPERATURE SENSOR
WIRE GUARD COVER OVER THERMOSTAT
('f
1 MD
DAMPER
M.D. MOTORIZED
NEW
REBALANCE
GENERAL NOTES
1. ALL DUCTWORK SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES: CODES,
RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF TUKWILA, AND THE 2006 INTERNATIONAL MECHANICAL CODE.
2. RECTANGULAR AND ROUND DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH SOUNDLINING OR EXTERNAL INSULATION WRAP AS
INDICATED IN NOTE 4 UNLESS OTHERWISE NOTED.
3. FLEXIBLE DUCTWORK SHALL BE CLASS 1 CONFORMING TO U.L. STANDARD 181 AS REQUIRED BY LOCAL CODE OR AGREEMENT.
4. DUCTWORK SHALL BE INSULATED PER THE TABLE BELOW
DUCTS REQUIRING INSULATION:
A. INDOOR, CONCEALED SUPPLY AND OUTDOOR AIR.
B. INDOOR, CONCEALED RETURN LOCATED IN NONCONDITIONED SPACE.
C. OUTDOOR, EXPOSED SUPPLY AND RETURN.
ITEMS NOT REQUIRING INSULATION:
A. METAL DUCTS WITH DUCT LINER OF SUFFICIENT THICKNESS TO COMPLY WITH LOCAL ENERGY CODE.
B. FACTORY - INSULATED FLEXIBLE DUCTS.
C. FLEXIBLE CONNECTORS.
D. VIBRATION- CONTROL DEVICES.
E. FACTORY - INSULATED ACCESS PANELS AND DOORS.
5. TAPE OR SEAL ALL JOINTS IN CONCEALED DUCTWORK SYSTEM
6. ALL CUTTING, PATCHING, FRAMING, FIRE SAFING, PAINTING, ROOF OPENING CURBS, ROOFING ETC., REQUIRED TO INSTALL MECHANICAL
SYSTEM HEREIN SHALL BE BY GENERAL CONTRACTOR, INCLUDING ALL FLASHING, SEALING, FRAMING AND ROOFING ON SHEET METAL
DUCT ENCLOSURES.
7. MECHANICAL EQUIPMENT ACCESS PANELS IN FURRED ENCLOSURES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR.
8. POWER WIRING AND CONNECTIONS TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. CONTROL WIRING AND LOW
VOLTAGE CONNECTION TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR.
9. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SHEET METAL.
10. ALL MEDIUM PRESSURE DUCT TO BE MANUFACTURED IN ACCORDANCE WITH SMACNA MEDIUM PRESSURE STANDARDS.
11. BUTTER ALL JOINTS AT SOUNDLINING IN MEDIUM PRESSURE DUCTWORK,
12. ALL MEDIUM PRESSURE DUCT TAKEOFF FITTINGS SHALL BE BOOT TEES UNLESS OTHERWISE NOTED.
13. INLET CONNECTIONS TO ALL MEDIUM PRESSURE TERMINAL UNITS SHALL HAVE BEAD AND CRIMP TO ASSURE POSITIVE FLEXIBLE DUCT
CONNECTION. MINIMUM FLEX DUCT LENGTH SHALL BE THREE FEET UNLESS RESTRICTED BY LOCAL CODE OR AGREEMENT.
14. ELEVATIONS SHOWN ON THESE DRAWINGS ARE INTENDED FOR DESIGN COORDINATION ONLY. REFER TO HVAC SHOP DRAWINGS FOR
EXACT ELEVATIONS AND DIMENSIONS.
15. CONTACTORS, MAGNETIC STARTERS AND DISCONNECT SWITCHES SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR,
UNLESS NOTED OTHERWISE.
16. DRAWINGS AND MANUALS SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY
CODE WITH SECTIONS 1416.
17. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH
SECTIONS 1416.2.3 - 1416.2.6.3.
18. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE
WITH SECTIONS 1416.2- 1416.2.3.
19. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE W /IBC, IMC & SMACNA SEISMIC STANDARDS.
20. PROVIDE PIPE INSULATION PER 14 -6 WSEC.
21. PROVIDE 5 DEGREE DEADBAND W/ AUTO SETBACK PER WSEC.
22. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICAL SYSTEMS PER WSEC TABLE 14-4.
23. EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT.
24. DUCT INSULATION IS SHOWN WHERE REQUIRED BY CODE. INSULATION OUTSIDE OF SHELL AND CORE AREAS SHALL BE PROVIDED AS
PART OF THE TENANT IMPROVEMENT PROJECTS,
25. EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 °F WITHIN WHICH THE SUPPLY OF HEATING AND
COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM.
26. MOTORIZED DAMPERS WILL BE PROVIDED TO CLOSE AUTOMATICALLY WHEN ITS RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE.
27. HEATING AND COOLING SYSTEMS SHALL HAVE OPTIMUM START CONTROLS.
28. AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO 100% OF THE DESIGN
SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING.
REVISIONS
No changes shall be amt be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submltt,r1
and may include additional plan revis r! feLs.
PARTIAL FAN INDUCTION TERMINAL UNIT SCHEDULE
MARK
MARK
MFRJ MODEL
AREA SERVED
FAN CFM
PRIMARY CFM
FAN
ELECTRIC HEATER
D.S.
INCLUDED
INLET
SIZE
AC SYS.
CRITICAL ZONE RESET
R.A. EXH.
EMCS FUNCTION
REMARKS
MAX
MIN
HP
SPEED
POWER
KW
POWER
SIS
TC
TOD GRP
FIT 2 -12
TRANE / VSEF 1004SQ
CHILD CARE 2D19, STORAGE 245
920
920
165
1/3
VAR
277V/1 PH
7.0
480V13PH
YES
10
AC-4
o
o
o
-
1, 2, 4, 6
FIT 2 -13
PSF 1 FAN INDUCTION
TERMINAL
OFFICE 250
750
750
-
1/6
120V/1 PH
-
-
-
-
AC-4
o
o
o
-
1, 2, 4, 6
1. PROVIDE WITH PRESSURE INDEPENDENT DDC CONTROLS, U.L. LISTING, S &D DISCHARGE FLANGE, TEMPERATURE SENSOR (MAMAC TE -205) WITHOUT LOGO, SCR FAN SPEED CONTROL, SERIES CONSTANT FAN, MERCURY CONTACTOR.
2. PROVIDE VARIABLE SPEED (SCR) FAN SPEED CONTROL.
3. PROVIDE THREE SPEED FAN SPEED CONTROL.
4. PROVIDE SINGLE STAGE ELECTRIC HEAT.
5. PROVIDE TWO STAGE ELECTRIC HEAT.
6. LINE FUSES AND DISCONNECT FURNISHED AND INSTALLED BY MANUFACTURER.
7. PROVIDE WITH BUTTON TEMPERATURE SENSOR.
8. I PROVIDE WITH REMOTE SENSOR AND ADJUSTABLE SENSOR.
SEPARATE PERMIT
REQUIRED FOR:
Q Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
,,BUILDING DIVISION
y REVIEWED FOR
CpDECOMPLIANCE
APPROVED
NOV 0 3 2010
AT 61V\
City ila
BUILDING VISION
FILE COPY
Permit
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the, violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By
Da : • �� -/
City Of 1Ukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
OCT 2 2 2010
PERMIT CENTER
PARTIAL DIFFUSER SCHEDULE
MARK
MFRIMODEL
NOTES
DESCRIPTION
B
ANEMOSTAT 1 PRT
TITUS 1 PMC-DF
24X24 LAY -IN
S.A.
PERFORATED TEGULAR LAY -IN DIFFUSER
G
ANEMOSTAT / 3PTD
TITUS / PDR
24X24 LAY -IN
R.A. EXH.
PERFORATED TEGULAR LAY -IN RETURN OR EXHAUST
GRILLE WITH DUCT COLLAR
N
ANEMOSTAT / S3HD
TITUS / 23RL
EXPOSED FASTENERS
R.A. 1 EXH.
SURFACE MOUNT RETURN OR EXHAUST GRILLE
DRAWING SCHEDULE
DWG.
DESCRIPTION
M -001
HVAC SCHEDULES AND GENERAL NOTES
M -121
SECOND FLOOR HVAC PLANS - DEMO AND NEW
COPYRIGHT (02010 CALLISON LLC
Z
a
w
0
o Z
0
0
O
0
O ' E
O O 0
coo - E
OMMO
>Q.t .r;
< M c) O
ooh
+-. - ch O
ti -
=coco c.
O +r 0 0
O N N N
CO •
0
ci
-C
N
M
O
N
0
0
O
w
CD
CO
M
co
0
0
CD
ti
0
O
N
1-
0
0
0
ao tB
co -C
00 0
co E
ti�
co
0
N 3
•
0
N
E
0
U
cn
0
0
21 0449.00
ISSUED / REVISED DATE
BID /PERMIT 10/11/10
HVAC SCHEDULES
AND GENERAL NOTES
M -001
N_
E
h
CI.
1
0
3
0
CL
•
c
2
s
U
0
0
c(0
0
cI
0
0
0
a
CC
CO
CO
CL
CL
N
w
E
D
C
B
(") PARTIAL SECOND FLOOR HVAC PLAN - DEMO
SCALE : 118 " =1' -0"
o
."C7
�r��
. `LL
/
iw
„t
12x12 8
420
10x10 B
2701-
;'— 98 "x1
1>0 <
1
I:.
10x4
120
225
10:x5 i ��I i 10x4 _.
40 !v i 140
•
8x8
130
PARTIAL SECOND FLOOR HVAC PLAN - NEW
SCALE : 118 " =1' -0"
( )
REVIEWED FOR
CODE
COMPLIANCE
APPROVED
NO 0 3 2010
City ofTuKWila
BUILDING DIVISION
th
<1 2)
RECEIVED.
CITY OFTUnwiLA
OCT 22 2010
PERMIT CENTER
LEGEND
- - DEMO
- EXiST1NG TO REMAIN
NEW DUCTWORK
CONSULTANT:
..c (NI E
l =Q o
. o U
L
i cu
t0 ▪ N p C)
O e-ED c �?
' < <CD N
N es Ci) E 41 d- ti 2 '- 2 CD c- N 0
W N CU CV 3
�. C)u) i1- I�. 3
•
E
z 0
O Z U
sn coc
o
E
1 V
✓ � 3
3
2 •
Oo
0
L— W
1.—"m1
(,,r) a
X
Do
ca
2
00
00
0)
210449.00
ISSUED / REVISED DATE
BID /PERMIT 10/11/10
SECOND FLOOR HVAC
PLANS - DEMO AND NEW
M-121