Loading...
HomeMy WebLinkAboutPermit M10-152 - NORDSTROMS - CHILD CARENORDSTROMS CHILD CARE 100 SOUTHCENTER MALL M10 -152 City ofaukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 9202470010 Address: 100 SOUTHCENTER MALL TUKW Project Name: NORDSTROMS CHILD CARE Permit Number: Issue Date: Permit Expires On: M10 -152 11/05/2010 05/04/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: Address: Email: KAREN GEORGE 9322 14 AV S , SEATTLE WA 98108 KGEORGE@PSFMECH.COM Contractor: Name: PSF MECHANICAL, INC. Address: 9322 14TH AVENUE SOUTH , SEATTLE, WA 98108 Contractor License No: PSFMEI *090NZ Phone: 206 812 -7678 Phone: 206 764 -9663 Expiration Date: 10/03/2011 DESCRIPTION OF WORK: MODIFY EXISTING MECHANICAL FOR SMALL TENANT REMODEL. REMOVE (1) FAN TERMINAL BOX AND REPLACE WITH NEW. Value of Mechanical: $10,000.00 Type of Fire Protection: SPRINKLERS /AFA Permit Center Authorized Signature I hereby certify that I have read and governing this work will be complie Fees Collected: $369.06 International Mechanical Code Edition: 2009 Date: D(l ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pre construction or the performance of work. back of this permit. Signature: Print Name: ( ! ;l' kt E{L This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: (/ t2 / doc: IMC -4/10 M10 -152 Printed: 01 -12 -2011 • • PERMIT CONDITIONS Permit No. M10-152 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M10 -152 Printed: 01 -12 -2011 City "Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 9202470010 Address: 100 SOUTHCENTER MALL TUKW Project Name: NORDSTROMS CHILD CARE Permit Number: M10 -152 Issue Date: 11/05/2010 Permit Expires On: 05/04/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: KAREN GEORGE Address: 9322 14 AV S , SEATTLE WA 98108 Email: KGEORGE@PSFMECH.COM Contractor: Name: PSF MECHANICAL, INC. Address: 9322 14TH AVENUE SOUTH , SEATTLE, WA 98108 Contractor License No: PSFMEI *090NZ Phone: 206 812 -7678 Phone: 206 764 -9663 Expiration Date: 10/03/2011 DESCRIPTION OF WORK: MODIFY EXISTING MECHANICAL FOR SMALL TENANT REMODEL. REMOVE (1) FAN TERMINAL BOX AND REPLACE WITH NEW. Value of Mechanical: $10,000.00 Type of Fire Protection: SPRINKLERS /AFA Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie x. wit Fees Collected: $306.06 International Mechanical Code Edition: 2009 Date: I I Gc I d ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: /7 } :— /7) This permit shall become null and void if the work is no commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10-152 Printed: 11 -05 -2010 • • wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Tenant: 100 SOUTHCENTER MALL TUKW NORDSTROMS CHILD CARE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M10 -152 ISSUED 10/22/2010 11/05/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 M10-152 Printed: 11 -05 -2010 • �J�.`N1LA wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: ry e_ Date: // / V doc: Cond -10/06 M10-152 Printed: 11 -05 -2010 • h • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us ff. Mechanical Permit No. Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.: 9202470010 Site Address: 100 Southcenter Mall Tenant Name: Nordstrom Inc. Suite Number: Property Owners Name: Westfield Property Mailing Address: PO Box 130940 New Tenant: Floor: ❑ Yes Carlsbad CA City State 2 .. No 92013 Zip CONTACT PERSON = who do we contact when your permit is ready to be issued Name: Karen George Mailing Address: 9322 14th Ave S Day Telephone: (206) 812 -7678 Seattle WA 98108 E -Mail Address: kgeorge @psfinech.com City State Fax Number: (206) 812 -7679 Zip MECHANICAL CONTRACTOR.INFORMATION Company Name: PSF Mechanical, Inc. Mailing Address: 9322 14th Ave S Seattle WA 98108 Contact Person: Wayne Champagne E -Mail Address: wchampagne@psfinech.com Contractor Registration Number: PSFMEI *090NZ City State Day Telephone: (206) 764 -9663 Fax Number: (206) 762 -8381 Expiration Date: 10/03/2011 Zip ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: PSF Mechanical, Inc. Mailing Address: 9322 14th Ave S Seattle WA 98108 Contact Person: Lawrence Palmer E -Mail Address: Ipalmer @psfinech.com H:Wpplications \Forms - Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh City State Day Telephone: (206) 764 -9663 Fax Number: (206) 762 -8381 Zip Page 1 of 2 • • Valuation of project (contractor's bid price): $ 10,000.00 Scope of work (please provide detailed information): Modify existing mechanical for small tenant remodel. Removing (1) Fan terminal box & replacing with new. These drawings were submitted with the general permit intake for Callison Architecture. Permit # D10 -278 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric m Gas ❑ Other: Indicate type of mechanical work being installed and the quanfty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm incinerator— comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE AGENT: Signature:�o�v( Date: 40- 0707—/ 7 Print Name: Karen George Day Telephone: (206) 812 -7678 Mailing Address: 9322 14th Ave S Seattle WA 98108 IDate Application Accepted: 10 City State Zip 22 LD Date Application Expires: C,L 2 tf Staff Initials: H:'Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised 7.2010 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Applicant: NORDSTROMS CHILD CARE 100 SOUTHCENTER MALL TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: M10 -152 ISSUED 10/22/2010 11/05/2010 Receipt No.: Initials: User ID: Payee: R10 -02532 JEM 1165 Payment Amount: $63.00 Payment Date: 12/17/2010 04:07 PM Balance: $0.00 PSF MECHANICAL, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. 014545 63.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 Total: $63.00 63.00 doc: Receiot -06 Printed: 12 -17 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 9202470010 Permit Number: M10 -152 Address: 100 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 10/22/2010 Applicant: NORDSTROMS CHILD CARE Issue Date: Receipt No.: R10 -02142 Payment Amount: $306.06 Initials: JEM Payment Date: 10/22/2010 10:37 AM User ID: 1165 Balance: $0.00 Payee: PSF MECHANICAL, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 014510 306.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 244.85 000.345.830 61.21 Total: $306.06 doc: Receiot -06 Printed: 10 -22 -2010 • • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT Na CITY OF TUKWILA BUILDING DIVISION 't 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431!`3670 Permit Inspection Request Line (206) 431 -2451 Mt & -(52 Proj cc . A ar 010i1-44,15 Cld at Type of Inspection: Address: Date Called: Special Instructions: ' Date Wanted: -., 1 I3 --If p.m. Requester: Phone No: 2.40(o -13O 9_t -? Approved per applicable codes. Corrections required prior to approval. COMMENTS: • pg, eel egg.", lele/A:V1/ Date: 1t�J CTION FEE REQUIFED. Prior, b next inspection. fee must be 6300 Southcenter B d.. Suite 00. Call to schedule reinspection. /41 /o - �sZ FIT AIR OUTLET TEST REPORT or'' Project Nordstrom child Proje t # System FC -3 Box Type Trane Split system BOX I.D.: FC -3 MODEL #: twh060p150a0 OUTLET AIRFLOW CFM (Us) % OF DESIGN SERIAL #: c47480904 AREA SERVED NO. TYPE SIZE DESIGN PRELIM. FINAL stroage 1 supply 12x12 250 440 370 148% storage 2 supply 12x12 250 440 380 152% child care 3 supply 12x12 300 520 380 127% child care 4 supply 12x12 300 400 470 157% storage 5 supply 12x12 250 240 410 164% 6 7 8 9 10 _ INLET SIZE : F/C : BOX TOTAL 1350 2040 2010 149% HEAT K.W.: AMPS : PRIMARY MAX FAN SPEED : Delta T : PRIMARY MIN FAN CFM BOX I.D. : MODEL #: OUTLET AIRFLOW CFM (Us) % OF DESIGN SERIAL #: AREA SERVED NO. TYPE SIZE DESIGN PRELIM. FINAL 1 2 3 4 5 6 7 8 9 10 INLET SIZE : F/C : BOX TOTAL HEAT K.W.: AMPS : PRIMARY MAX FAN SPEED : Delta T : PRIMARY MIN FAN CFM REMARKS (1) Wide Open Path Found 5 ton split system in lieu of FIT box. Recalculated proportional values based on initial total reading of 2040 cfm. Proportionally balanced as shown. Date: Readings by: ettitill WON WV PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -152 DATE: 12 -15 -10 PROJECT NAME: NORDSTROMS CHILD CARE SITE ADDRESS: 100 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: PA. ding �lvision� �`1� Public Works ❑ AA N A- e Prevention Structural n Planning Division Permit Coordinator n • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -16 -10 Complete Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01-13 -11 Approved IX Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • lERACT D COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -152 DATE: 10/22/10 PROJECT NAME: NORDSTROMS CHILD CARE SITE ADDRESS: 100 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: �' A`L�10\ B I ing Division Fire Prevenitvid ❑ Structural ❑ Public Works Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 10/26/10 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 11/23/10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 PROJECT NAME: Doris. „Ais_ C L SITE ADDRESS: kPO T'o i 1 PERMIT NO: IA I n' ORIGINAL ISSUE DATE: -1 REVISION LOG REVISION NO. DATE'RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE STAFF INITIALS k).--AT— 0 (AL \ Ant 10 Received by: . Summary of Revision: pe c,.e Sc, O uldrk, 4 f ,e c-1..; •may .# �,� ►,� Received by: I � c j (3- E or a r REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE STAFF .INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: City of Tukwila ! REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http. / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12/xx./10 Plan Check/Permit Number: --D44-2q'8 Vt (0— (S a., ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # • Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Nordstrom Southcenter -Child Area Project Address: 100 Southcenter Mall Contact Person: Wayne Champagne Phone Number: (206) 227 -8171 Summary of Revision: Original design was installing a new terminal box and duct distribution. New design is reusing the existing terminal box and duct distribution and relocating supply grills RECEIVED env OF TUKIMLA IDEC115.2010 PERMIT Sheet Number(s): M -001 and M -121 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: tq Entered in Permits Plus on CO H:\Applications\Forrns- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 `RJ__ Contractors or Tradespeople Peter Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name P S F MECHANICAL INC UBI No. 601318369 Phone 2067649663 Status Active Address 9322 14Th Ave 5 License No. PSFMEI'090NZ Suite /Apt. License Type Construction Contractor City Seattle Effective Date 8/9/1991 State WA Expiration 10/3/2011 Date Zip 98108 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EDENN "225LKEDEN NURSERIES Construction Contractor General Unused 6/12/1978 6/1/1986 Archived Business Owner Information Name Role Effective Date Expiration Date BEARDSLEY, WARREN 5 Cancel Date 01/01/1980 Bond Amount CRITCHLOW, JAMES D 4 01/01/1980 08973126 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIDELITY & DEPOSIT CO OF MD 08973126 08/08/2009 Until Cancelled $6,000.0007/10/2009 09/29/2010 3 HARTFORD FIRE INS 52BSBFA6327 08/08/2008 Until Cancelled 08/08/2009 $6,000.00 07/08/2008 2 FEDERAL INS CO 81241859 08/08/2001 08/08/2008 $6,000.0010/01/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 18 WAUSAU UNDERWRITERS INS. CO. TBJZ91452741020 10/01/2010 10/01/2011 $1,000,000.00 09/29/2010 17 WAUSAU BUSINESS INS CO TBJZ91452741029 10/01/2009 10/01/2010 $1,000,000.00 10/07/2009 16 WAUSAU UNDERWRITERS INS. CO. TBJZ9145274109 10/01/2009 10/01/2010 $1,000,000.00 09/28/2009 15 TRAVELERS PROPERTY CAS INS CO DTEC0527D0578TIL08 10/01/2008 10/01/2009 $1,000,000.0009 /23/2008 https : / /fortre s s. wa. gov /l ni/bbip /Print. aspx 11/05/2010 SYMBOLS & ABBREVIATIONS SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION AREA SERVED -- 0 A.C. AIR CONDITIONLNC, UNIT A.D. AIR DOOR A.F.F. ABOVE FINISHED FLOOR KW AC AC 71 MECHANICAL EQUIPMENT TAG FLA STAGES NOM. NOMINAL /D../X/ O.B.D. OPPOSED BLADE DAMPER 8.5 ORIFICE SIZE (INCHES) O.A. OUTSIDE AIR OV. OVAL /// P.B.D. PARALLEL BLADE DAMPER P.O.G. POINT OF CONNECTION REMARKS B.D.D. BACKDRAFT DAMPER B.S. BIRD SCREEN B.O.G. BOTTOM OF GRILLE B.O.D. BOTTOM OF DUCT BT B.T. BYPASS TIMER 4. CENTER LINE CUH CABINET UNIT HEATER DIA. DIAMETER D.S. DISCONNECT SWITCH D.T.S. DUCT TEMPERATURE SENSOR -----*- R RE R. RELOCATE R.A. RETURN AIR R.B. REBALANCE R.A.G. RETURN MR GRILLE R.V.D. REMOTE VOLUME DAMPER li RETURN DUCT DOWN 1350 �.` 277V11PH 1 C D.G. DOOR GRILLE Q DRAWING NOTE 1871,., SERVED BY FIT 2 -12 EDC 2.12 11 RETURN DUCT UP �- D - D DUCT DROP IN DIRECTION OF ARROW 2ND 750 1.0 277V11PH ®, SIDE INLET CAN �- R . R DUCT RISE IN DIRECTION OF ARROW DN. DOWN E.G.H. ELECTRIC CEILING HEATER E.D.C. ELECTRIC DUCT COIL E.F.C. ELECTRIC FAN COIL E.U.H. ELECTRIC UNIT HEATER E.C. ELECTRICAL CONTRACTOR G ELEVATION EXIST. EXISTING E.A. EXHAUST AIR E.F. EXHAUST FAN EXT. EXTERIOR OR EXTERNAL SERVED BY FIT 2 -13 SD 1 S.D. SMOKE DETECTOR a 0 S. DMPR. SMOKE DAMPER S.P.F. SMOKE PURGE FAN S.S.S.C. SOLID STATE SPEED CONTROL Jr S.L. SOUND LINING SPLITTER DAMPER SP. DMPR. RECT. - ROUND SQUARE TO ROUND DUCT TRANSITION S/S START /STOP SP STATIC PRESSURE SENSOR 1></N S.A. SUPPLY AIR 1‘/C) SUPPLY DUCT DOWN 4 1 SUPPLY DUCT UP 'z` EXTR. EXTRACTOR 'rte F.I.T. FAN INDUCTION TERMINAL FD F.D FIRE DAMPER' OS ® OT ):171:2"‘"": AV SW. SWITCH T.C. TEMPERATURE CONTROL T.S. TEMPERATURE SENSOR TSTAT. THERMOSTAT TOP INLET LAY -IN T.O.D. TOP OF DUCT T.F. TRANSFER FAN T.V. TURNING VANES U.D. UNDERCUT DOOR V.A.V. VARIABLE MR VOLUME TERMINAL FSD F.S.D. FIREISMOKE DAMPER F.O.B. FLAT ON BOTTOM F.O.T. FLAT ON TOP 11 I 1 I 1 I[Jr F.C. FLEXIBLE CONNECTION • G.C. GENERAL CONTRACTOR DIFFUSER TYPE GRILLE, REGISTER,-OR A 8x8 NECK SIZE (INCHES) 200 AIR QUANTITY (CFM) GIRD I.D. NUMBER H.P. HEAT PUMP OR HORSEPOWER INT. INTERLOCK M.U.A. MAKE -UP AIR M.U.F. MAKE -UP AIR FAN M.C. MECHANICAL CONTRACTOR V.D. VOLUME DAMPER CC C--N T O WIRE GUARD COVER OVER TEMPERATURE SENSOR WIRE GUARD COVER OVER THERMOSTAT 1 MOTORIZED DAMPER MD M.D. GENERAL NOTES 1. ALL DUCTWORK SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES: CODES, RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF TUKWILA, AND THE 2006 INTERNATIONAL MECHANICAL CODE. 2. RECTANGULAR AND ROUND DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH SOUNDLINING OR EXTERNAL INSULATION WRAP AS INDICATED IN NOTE 4 UNLESS OTHERWISE NOTED. 3. FLEXIBLE DUCTWORK SHALL BE CLASS 1 CONFORMING TO U.L. STANDARD 181 AS REQUIRED BY LOCAL CODE OR AGREEMENT. 4. DUCTWORK SHALL BE INSULATED PER THE TABLE BELOW DUCTS REQUIRING INSULATION: A. INDOOR, CONCEALED SUPPLY AND OUTDOOR AIR. B. INDOOR, CONCEALED RETURN LOCATED IN NONCONDITIONED SPACE. C. OUTDOOR, EXPOSED SUPPLY AND RETURN. ITEMS NOT REQUIRING INSULATION: A. METAL DUCTS WITH DUCT LINER OF SUFFICIENT THICKNESS TO COMPLY WITH LOCAL ENERGY CODE. B. FACTORY- INSULATED FLEXIBLE DUCTS. C. FLEXIBLE CONNECTORS. D. VIBRATION - CONTROL DEVICES. E. FACTORY - INSULATED ACCESS PANELS AND DOORS. 5. TAPE OR SEAL ALL JOINTS IN CONCEALED DUCTWORK SYSTEM 6. ALL CUTTING, PATCHING, FRAMING, FIRE SAFING, PAINTING, ROOF OPENING CURBS, ROOFING ETC,, REQUIRED TO INSTALL MECHANICAL SYSTEM HEREIN SHALL BE BY GENERAL CONTRACTOR, INCLUDING ALL FLASHING, SEALING, FRAMING AND ROOFING ON SHEET METAL DUCT ENCLOSURES. 7. MECHANICAL EQUIPMENT ACCESS PANELS IN FURRED ENCLOSURES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 8. POWER WRING AND CONNECTIONS TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. CONTROL WIRING AND LOW VOLTAGE CONNECTION TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. 9. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SHEET METAL. 10. ALL MEDIUM PRESSURE DUCT TO BE MANUFACTURED IN ACCORDANCE WITH SMACNA MEDIUM PRESSURE STANDARDS. 11. BUTTER ALL JOINTS AT SOUNDLINING IN MEDIUM PRESSURE DUCTWORK. 12. ALL MEDIUM PRESSURE DUCT TAKEOFF FITTINGS SHALL BE BOOT TEES UNLESS OTHERWISE NOTED. 13. INLET CONNECTIONS TO ALL MEDIUM PRESSURE TERMINAL UNITS SHALL HAVE BEAD AND CRIMP TO ASSURE POSITIVE FLEXIBLE DUCT CONNECTION. MINIMUM FLEX DUCT LENGTH SHALL BE THREE FEET UNLESS RESTRICTED BY LOCAL CODE OR AGREEMENT. 14. ELEVATIONS SHOWN ON THESE DRAWINGS ARE INTENDED FOR DESIGN COORDINATION ONLY. REFER TO HVAC SHOP DRAWINGS FOR EXACT ELEVATIONS AND DIMENSIONS. 15. CONTACTORS, MAGNETIC STARTERS AND DISCONNECT SWITCHES SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 16. DRAWINGS AND MANUALS SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416. 17. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2.3- 1416.2.6.3. 18. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2 - 1416.2.3. 19. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE W /IBC, IMC & SMACNA SEISMIC STANDARDS. 20. PROVIDE PIPE INSULATION PER 14-6 WSEC. 21. PROVIDE 5 DEGREE DEADBAND W/ AUTO SETBACK PER WSEC. 22. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICAL SYSTEMS PER WSEC TABLE 14-4. 23. EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT. 24. DUCT INSULATION IS SHOWN WHERE REQUIRED BY CODE. INSULATION OUTSIDE OF SHELL AND CORE AREAS SHALL BE PROVIDED AS PART OF THE TENANT IMPROVEMENT PROJECTS. 25. EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 °F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM. 26. MOTORIZED DAMPERS WILL BE PROVIDED TO CLOSE AUTOMATICALLY WHEN IT'S RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE. 27. HEATING AND COOLING SYSTEMS SHALL HAVE OPTIMUM START CONTROLS. 28. AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO 100% OF THE DESIGN SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING. REBALANCE EXISTING SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical L'�Electrical Plumbing Las Piping i`y of Tukwila Et ° _`'IS'J11 DIVISION FILE COPY Permit No Plan review approval is subject to errors and � authorize approval of construction documents does lh violation of any adopted code or ordinance. Receipt of approved Field Co • and conditions is + owledged: By Date: ,-)y-/V - '""'""'" City Of 'htkwHa BUILDING DIVISION M REVISIONS No changes shalt b e made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new p!an submittal and may inc ude additional plan review fscs. REVIEWED FOR CODE COMPLIANCE DEC 16 2U10 �S `1 City of Tukwila BUILDING MINION REVISION.N,01 __l RECEIVED DEC 15 2010 PERMIT CENTER PARTIAL ELECTRIC DUCT HEATER SCHEDULE MARK MFR 1 MODEL AREA SERVED FLOOR CFM KW POWER FLA STAGES DUCT SIZ"w REMARKS EDC 2 -11 REDD -I / MODEL R CHILDREN'S PLAY AREA 2ND 1350 3.5 277V11PH 12:6 1 1871,., SERVED BY FIT 2 -12 EDC 2.12 REDD -I I MODEL R OFFICES 2ND 750 1.0 277V11PH I 3.6 1 14712" SERVED BY FIT 2 -13 PARTIAL FAN INDUCTION TERMINAL UNIT SCHEDULE MARK MFRJ MODEL PSF / FAN INDUCTION TERMINAL PSF /FAN INDUCTION TERMINAL AREA SERVED CHILD CARE 2D19, STORAGE 245 FAN CFM 1350 PRIMARY CFM MAX MIN 1350 165 HP (2) 1/3 FAN SPEED ELECTRIC HEATER POWER KW POWER D.S. INCLUDED INLET SIZE AC SYS. CRITICAL ZONE RESET EMCS FUNCTION REMARKS S/S TC TOD GRP VAR 277V/1 PH AC-4 0 0 0 OFFICE 250 750 750 116 120V/1 PH AC -4 0 0 0 PARTIAL DIFFUSER SCHEDULE MARK MFR/MODEL T NOTES DESCRIPTION B ANEMOSTAT 1 PRT TITUS 1 PMC -DF 24X24 LAY -IN S.A. PERFORATED TEGULAR LAY -IN DIFFUSER G ANEMOSTAT 13PTD T ITUS 1 PDR „ „ , , 24X24 LA VIN R.A. 1 EXH. PERFORATED TEGULAR LAY -IN RETURN OR EXHAUST GRILLE'vVITH DUCT COLLAR N ANEMOSTATI S3HD TITUS / 23RL EXPOSED FASTENERS R.A.,' EXH. SURFACE MOUNT RETURN OR EXHAUST GRILLE DRAWING SCHEDULE DWG. DESCRIPTION M -001 HVAC SCHEDULES AND GENERAL NOTES M -121 SECOND FLOOR HVAC PLANS - DEMO AND NEW (.' -. 211T _ . z 0 J J z i w O O z 0 m M 0 M CO 0 N H 0.0 Q o0 `C > o CO to > m ¢Qo) au -m !n N *iQ ZO � M �N o . a) U) I- IL E 7nR '1n1 L'l1 ta Ina 7R9 RlR9 E 0 7 0 a ta r .U) 1 ..1 c t9 } O 1-az V J 0 0 SOUT CENTER WA 98188 210449.00 ISSUED / REVISED DATE BID /PERMIT 10/11/10 BID SET 11/02/10 BID /PERMIT SCOPE REDUCTION 12/09/10 HVAC SCHEDULES AND GEMERAL MOTES MOO1 } PARTIAL SECOND FLOOR HVAC PLAN - DEMO SCALE : 118 " =1' -0" 9 `, /T Tl /7 I \ / ‘c. \ ;. X1 • a c _ 12)12 I 13 2O \ r "A: 2f; r4 ti -713-71 I rx 1 4' ! ) -5 711 I -1�1 s 1 Ii •rii- Tr 1- +11 _! 111 1 1 1 4 �I� g 10x4 120 iff 1-1-1 11 10x4 10x4 ft Bxs 130 r .1 I REVISION N0:1 HIO I52 REVIEWED FOR C ODE COMPLIANCE PionnVE DEC 162010 City of Tukwila BUILDING DivI41GN PARTIAL SECOND FLOOR HVAC PLAN - NEW SCALE : 1i8 " =1'-0" RECEIVED DEC 15 2010 PERMIT CENTER LEGEND — DEMO NEW DUC1' 0RK O O 0 O 0 m O Z U 0 ma 0 zl N a CO U j 7 ;7, 0 co x-- co • 0.) cm 0 4.-.= � o � o O I- ca r z C 7fR '2n'.r Lta1• F 7nR 7R7 A'R1 210449.00 ISSUED / REVISED DATE BID /PERMIT 10/11/10 BID SET 11/02/10 BID /PERMIT SCOPE REDUCTION 12/09/10 SECOND FLOOR HVAC PLANS - DEMO AND NEW Mw121 F E D C B 6 14 SYMBOLS & ABBREVIATIONS SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION MFRJ MODEL W o A.C. AIR CONDITIONING UNIT A.U. AIR DOOR A.F.F. ABOVE FINISHED FLOOR PRIMARY CFM AC-XXX) EQUIPMENT TAG MECHANICAL Q D.S. INCLUDED NOM. NOMINAL /X/X/ O.B.D. OPPOSED BLADE DAMPER 8.5 ORIFICE SIZE (INCHES) O.A. OUTSIDE AIR OV. OVAL /// P.B.D. PARALLEL BLADE DAMPER _ „�,, P.O.C. POINT OF CONNECTION AC SYS. B.D.D. BACKDRAFT DAMPER B.S. BIRD SCREEN B.O.G. BOTTOM OF GRILLE B.O.D. BOTTOM OF DUCT BT B.T. BYPASS TIMER CENTER LINE CUH CABINET UNIT HEATER DIA. DIAMETER D.S. DISCONNECT SWITCH D.T.S. DUCT TEMPERATURE SENSOR --"---e, R RB R. RELOCATE R.A. RETURN AIR R.B. REBALANCE R.A.G. RETURN AIR GRILLE R.V.D. REMOTE VOLUME DAMPER MAX D.G. DOOR GRILLE 0 DRAWING NOTE SPEED .��� `, ,) RETURN DUCT DOWN POWER SIS I ® RETURN DUCT UP f. D Jr D DUCT DROP IN DIRECTION OF ARROW FIT 2 -12 TRANE / VSEF 1004SQ CHILD CARE 2D19, STORAGE 245 920 ►� '"'" SIDE INLET CAN Jr____ j R DUCT RISE IN DIRECTION OF ARROW DN. DOWN E.C.H. ELECTRIC CEILING HEATER E.D.C. ELECTRIC DUCT COIL E.F.C. ELECTRIC FAN C01! E.U.H. ELECTRIC UNIT HEATER E.C. ELECTRICAL CONTRACTOR ELEVATION EXIST. EXISTING E.A. EXHAUST AIR E.F. EXHAUST FAN EXT. EXTERIOR OR EXTERNAL VAR 277V/1 PH 7.0 I SD { YES S.D. SMOKE DETECTOR 0 DMPR. S. SMOKE DAMPER S.P.F. SMOKE PURGE FAN S.S.S.C. SOLID STATE SPEED CONTROL t S.L. SOUND LINING - 1, 2, 4, 6 FIT 2 -13 SP. DMPR. SPLITTER DAMPER RECT. ROUND 750 SQUARE TO ROUND DUCT TRANSITION - 1 S/S START /STOP SP STATIC PRESSURE SENSOR - - S.A. SUPPLY AIR o EXTR. EXTRACTOR F.I.T. FAN INDUCTION TERMINAL - /\ SUPPLY DUCT DOWN . ) ® SUPPLY DUCT UP Al FD F.D FIRE DAMPER 0 6 Q SW. SWITCH T.C. TEMPERATURE CONTROL T.S. TEMPERATURE SENSOR T'STAT. THERMOSTAT FSD F.S.D. FIRE /SMOKE DAMPER F.O.B. FLAT ON BOTTOM F.O.T. FLAT ON TOP )2( TOP INLET LAY -IN 3 1111111 I F.C. FLEXIBLE CONNECTION G.C. GENERAL CONTRACTOR TYPE T.O.D. TOP OF DUCT T.F. TRANSFER FAN i GRILLE, REGISTER, OR DIFFUSER } T.V. TURNING VANES A 8x8 NECK SIZE (INCHES) 200 AIR QUANTITY (CFM)_ GiRID I.D. NUMBER H.P. HEAT PUMP OR HORSEPOWER INT. INTERLOCK M.U.A. MAKE -UP AIR M.U.F. MAKE -UP AIR FAN M.C. MECHANICAL CONTRACTOR U.D. UNDERCUT DOOR V.A.V. VARIABLE AIR VOLUME TERMINAL tiltill V.D. VOLUME DAMPER re 1 WIRE GUARD COVER OVER TEMPERATURE SENSOR WIRE GUARD COVER OVER THERMOSTAT ('f 1 MD DAMPER M.D. MOTORIZED NEW REBALANCE GENERAL NOTES 1. ALL DUCTWORK SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES: CODES, RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF TUKWILA, AND THE 2006 INTERNATIONAL MECHANICAL CODE. 2. RECTANGULAR AND ROUND DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH SOUNDLINING OR EXTERNAL INSULATION WRAP AS INDICATED IN NOTE 4 UNLESS OTHERWISE NOTED. 3. FLEXIBLE DUCTWORK SHALL BE CLASS 1 CONFORMING TO U.L. STANDARD 181 AS REQUIRED BY LOCAL CODE OR AGREEMENT. 4. DUCTWORK SHALL BE INSULATED PER THE TABLE BELOW DUCTS REQUIRING INSULATION: A. INDOOR, CONCEALED SUPPLY AND OUTDOOR AIR. B. INDOOR, CONCEALED RETURN LOCATED IN NONCONDITIONED SPACE. C. OUTDOOR, EXPOSED SUPPLY AND RETURN. ITEMS NOT REQUIRING INSULATION: A. METAL DUCTS WITH DUCT LINER OF SUFFICIENT THICKNESS TO COMPLY WITH LOCAL ENERGY CODE. B. FACTORY - INSULATED FLEXIBLE DUCTS. C. FLEXIBLE CONNECTORS. D. VIBRATION- CONTROL DEVICES. E. FACTORY - INSULATED ACCESS PANELS AND DOORS. 5. TAPE OR SEAL ALL JOINTS IN CONCEALED DUCTWORK SYSTEM 6. ALL CUTTING, PATCHING, FRAMING, FIRE SAFING, PAINTING, ROOF OPENING CURBS, ROOFING ETC., REQUIRED TO INSTALL MECHANICAL SYSTEM HEREIN SHALL BE BY GENERAL CONTRACTOR, INCLUDING ALL FLASHING, SEALING, FRAMING AND ROOFING ON SHEET METAL DUCT ENCLOSURES. 7. MECHANICAL EQUIPMENT ACCESS PANELS IN FURRED ENCLOSURES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 8. POWER WIRING AND CONNECTIONS TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. CONTROL WIRING AND LOW VOLTAGE CONNECTION TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. 9. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SHEET METAL. 10. ALL MEDIUM PRESSURE DUCT TO BE MANUFACTURED IN ACCORDANCE WITH SMACNA MEDIUM PRESSURE STANDARDS. 11. BUTTER ALL JOINTS AT SOUNDLINING IN MEDIUM PRESSURE DUCTWORK, 12. ALL MEDIUM PRESSURE DUCT TAKEOFF FITTINGS SHALL BE BOOT TEES UNLESS OTHERWISE NOTED. 13. INLET CONNECTIONS TO ALL MEDIUM PRESSURE TERMINAL UNITS SHALL HAVE BEAD AND CRIMP TO ASSURE POSITIVE FLEXIBLE DUCT CONNECTION. MINIMUM FLEX DUCT LENGTH SHALL BE THREE FEET UNLESS RESTRICTED BY LOCAL CODE OR AGREEMENT. 14. ELEVATIONS SHOWN ON THESE DRAWINGS ARE INTENDED FOR DESIGN COORDINATION ONLY. REFER TO HVAC SHOP DRAWINGS FOR EXACT ELEVATIONS AND DIMENSIONS. 15. CONTACTORS, MAGNETIC STARTERS AND DISCONNECT SWITCHES SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 16. DRAWINGS AND MANUALS SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416. 17. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2.3 - 1416.2.6.3. 18. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2007 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2- 1416.2.3. 19. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE W /IBC, IMC & SMACNA SEISMIC STANDARDS. 20. PROVIDE PIPE INSULATION PER 14 -6 WSEC. 21. PROVIDE 5 DEGREE DEADBAND W/ AUTO SETBACK PER WSEC. 22. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICAL SYSTEMS PER WSEC TABLE 14-4. 23. EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT. 24. DUCT INSULATION IS SHOWN WHERE REQUIRED BY CODE. INSULATION OUTSIDE OF SHELL AND CORE AREAS SHALL BE PROVIDED AS PART OF THE TENANT IMPROVEMENT PROJECTS, 25. EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5 °F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM. 26. MOTORIZED DAMPERS WILL BE PROVIDED TO CLOSE AUTOMATICALLY WHEN ITS RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE. 27. HEATING AND COOLING SYSTEMS SHALL HAVE OPTIMUM START CONTROLS. 28. AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO 100% OF THE DESIGN SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING. REVISIONS No changes shall be amt be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submltt,r1 and may include additional plan revis r! feLs. PARTIAL FAN INDUCTION TERMINAL UNIT SCHEDULE MARK MARK MFRJ MODEL AREA SERVED FAN CFM PRIMARY CFM FAN ELECTRIC HEATER D.S. INCLUDED INLET SIZE AC SYS. CRITICAL ZONE RESET R.A. EXH. EMCS FUNCTION REMARKS MAX MIN HP SPEED POWER KW POWER SIS TC TOD GRP FIT 2 -12 TRANE / VSEF 1004SQ CHILD CARE 2D19, STORAGE 245 920 920 165 1/3 VAR 277V/1 PH 7.0 480V13PH YES 10 AC-4 o o o - 1, 2, 4, 6 FIT 2 -13 PSF 1 FAN INDUCTION TERMINAL OFFICE 250 750 750 - 1/6 120V/1 PH - - - - AC-4 o o o - 1, 2, 4, 6 1. PROVIDE WITH PRESSURE INDEPENDENT DDC CONTROLS, U.L. LISTING, S &D DISCHARGE FLANGE, TEMPERATURE SENSOR (MAMAC TE -205) WITHOUT LOGO, SCR FAN SPEED CONTROL, SERIES CONSTANT FAN, MERCURY CONTACTOR. 2. PROVIDE VARIABLE SPEED (SCR) FAN SPEED CONTROL. 3. PROVIDE THREE SPEED FAN SPEED CONTROL. 4. PROVIDE SINGLE STAGE ELECTRIC HEAT. 5. PROVIDE TWO STAGE ELECTRIC HEAT. 6. LINE FUSES AND DISCONNECT FURNISHED AND INSTALLED BY MANUFACTURER. 7. PROVIDE WITH BUTTON TEMPERATURE SENSOR. 8. I PROVIDE WITH REMOTE SENSOR AND ADJUSTABLE SENSOR. SEPARATE PERMIT REQUIRED FOR: Q Mechanical Electrical Plumbing Gas Piping City of Tukwila ,,BUILDING DIVISION y REVIEWED FOR CpDECOMPLIANCE APPROVED NOV 0 3 2010 AT 61V\ City ila BUILDING VISION FILE COPY Permit Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the, violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By Da : • �� -/ City Of 1Ukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 2 2 2010 PERMIT CENTER PARTIAL DIFFUSER SCHEDULE MARK MFRIMODEL NOTES DESCRIPTION B ANEMOSTAT 1 PRT TITUS 1 PMC-DF 24X24 LAY -IN S.A. PERFORATED TEGULAR LAY -IN DIFFUSER G ANEMOSTAT / 3PTD TITUS / PDR 24X24 LAY -IN R.A. EXH. PERFORATED TEGULAR LAY -IN RETURN OR EXHAUST GRILLE WITH DUCT COLLAR N ANEMOSTAT / S3HD TITUS / 23RL EXPOSED FASTENERS R.A. 1 EXH. SURFACE MOUNT RETURN OR EXHAUST GRILLE DRAWING SCHEDULE DWG. DESCRIPTION M -001 HVAC SCHEDULES AND GENERAL NOTES M -121 SECOND FLOOR HVAC PLANS - DEMO AND NEW COPYRIGHT (02010 CALLISON LLC Z a w 0 o Z 0 0 O 0 O ' E O O 0 coo - E OMMO >Q.t .r; < M c) O ooh +-. - ch O ti - =coco c. O +r 0 0 O N N N CO • 0 ci -C N M O N 0 0 O w CD CO M co 0 0 CD ti 0 O N 1- 0 0 0 ao tB co -C 00 0 co E ti� co 0 N 3 • 0 N E 0 U cn 0 0 21 0449.00 ISSUED / REVISED DATE BID /PERMIT 10/11/10 HVAC SCHEDULES AND GENERAL NOTES M -001 N_ E h CI. 1 0 3 0 CL • c 2 s U 0 0 c(0 0 cI 0 0 0 a CC CO CO CL CL N w E D C B (") PARTIAL SECOND FLOOR HVAC PLAN - DEMO SCALE : 118 " =1' -0" o ."C7 �r�� . `LL / iw „t 12x12 8 420 10x10 B 2701- ;'— 98 "x1 1>0 < 1 I:. 10x4 120 225 10:x5 i ��I i 10x4 _. 40 !v i 140 • 8x8 130 PARTIAL SECOND FLOOR HVAC PLAN - NEW SCALE : 118 " =1' -0" ( ) REVIEWED FOR CODE COMPLIANCE APPROVED NO 0 3 2010 City ofTuKWila BUILDING DIVISION th <1 2) RECEIVED. CITY OFTUnwiLA OCT 22 2010 PERMIT CENTER LEGEND - - DEMO - EXiST1NG TO REMAIN NEW DUCTWORK CONSULTANT: ..c (NI E l =Q o . o U L i cu t0 ▪ N p C) O e-ED c �? ' < <CD N N es Ci) E 41 d- ti 2 '- 2 CD c- N 0 W N CU CV 3 �. C)u) i1- I�. 3 • E z 0 O Z U sn coc o E 1 V ✓ � 3 3 2 • Oo 0 L— W 1.—"m1 (,,r) a X Do ca 2 00 00 0) 210449.00 ISSUED / REVISED DATE BID /PERMIT 10/11/10 SECOND FLOOR HVAC PLANS - DEMO AND NEW M-121