HomeMy WebLinkAboutPermit M10-159 - SHASTA BEVERAGESSHASTA BEVERAGE 1227 ANDOVER PK E M10 -159 City ofkukwila a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 3523049072 Address: 1227 ANDOVER PK E TUKW Project Name: SHASTA BEVERAGES Permit Number: M10-159 Issue Date: 12/02/2010 Permit Expires On: 05/31/2011 Owner: Name: NATIONAL BEVERAGE CORP Address: 8100 SW 10TH ST STE 4000 , PLANTATION FL 33324 Contact Person: Name: BRYAN GALVIN Address: PO BOX 614 , AUBURN WA 98071 Email: BRYAN @UNIVERSALREFRIG.COM Contractor: Name: UNIVERSAL REFRIGERATION INC Address: PO BOX 614 , AUBURN WA 98071 -0614 Contractor License No: UNIVERI159RF Phone: 253 - 939 -5501 Phone: 253 939 -5501 Expiration Date: 04/01/2012 DESCRIPTION OF WORK: INSTALL (2) ROOF FANS AND (2) UNIT HEATERS. Value of Mechanical: $7,400.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $281.56 International Mechanical Code Edition: 2009 Date: 12 [Ml p I hereby certify that I have read and (exanlined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not pre -uhte to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signatur Print Name: c° l�Je\t/1 Date: t/ Z (t') This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC-4/10 M10 -159 Printed: 12 -02 -2010 • • PERMIT CONDITIONS Permit No. M10 -159 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: AU mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2007 edition). 13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M10 -159 Printed: 12 -02 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. 144 10- s Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: ,F2-,.. 04/ — 90 72_ Site Address: /7-7.- 7 4ae• vey• nCwi s itS71 Suite Number: Tenant Name: ,... aciert P�t/t4,2, 4, • Property Owners Name: i1474c ".4 / SWe-rw ,e. C.70 . Mailing Address: / 2. -1 �btelo 4.r- _g/ New Tenant: Floor: ❑ Yes ❑ ..No //, ew;/4 City t444 • State 9'8698 Zip CONTA T PERSON - Who do we hr 4=4-*/ r �G.^7 'CH 4iMRN,1Day Telephone: 2 9 3q Name: Mailing Address: PO 6. E -Mail Address: tl wAl g5071- City State Zip Fax Number: Z5, —735— — Company Name: Mailing Address: Contact Person: E -Mail Address: GI/ �Gi w-V�► WA- - y'$ °°/ City State Zip Day Telephone: 2-53 93 9 5-5-6 / Fax Number: Expiration Date: Contractor Registration Number: a e r 4' /V/t P( / Company Name: Mailing Address: City • Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:4kpplicafions\Porms- Applications On Line\2009 Applications \ 1-2009 - Mechanical Permit Application.doe Revised: 1 -2009 State Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ 74/00 \ pe 5 tea'/ /4;caide --- 745p al" 1- v). Scope of Work (please provide detailed information): At - /( rzlr) vao f ft4.1 5/ (-) (444 �] „C'( #3.., r' /9//ae, CA44t4^4 () ittA /d-t..J Vo /Its L✓igrt Use: Residential: New Commercial: New Fuel Type: Electric ❑ Lam' Replacement Replacement Gas Other: Indicate type of mechanical work being installed and the quantity below: Unit Types Qty Unit Type: Qty Unit TYPe: Qty Boiler' /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper , 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Fumace Ventilation Fan Connected to Single Duct Z Thermostat Z- 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater 2 Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm/Ind Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ER • • WiA� %�; Signa . e: Print N Mailing Address: Day Telephone: a. Fay es,y Date: 1/— (z$- 3>',, -ccO( Gr/ . Y8D7/ -D4 y State Zip Date Application Accepted: �` i III Date Application Expires: ` (� _ Staff Initials: V____ I H: WpplicationsWonns- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application:doe Revised: 1 -2009 bh Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htq)://www.ci.tulcwila.wa.us RECEIPT Parcel No.: 3523049072 Permit Number: M10 -159 Address: 1227 ANDOVER PK E TUKW Status: PENDING Suite No: Applied Date: 11/15/2010 Applicant: SHASTA BEVERAGES Issue Date: Receipt No.: R10 -02306 Payment Amount: $281.56 Initials: WER Payment Date: 11/15/2010 11:32 AM User ID: 1655 Balance: $0.00 Payee: UNIVERSAL REFRIGERATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 42303 281.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 225.25 000.345.830 56.31 Total: $281.56 doc: Receiot -06 Printed: 11 -15 -2010 k F. ' 2-- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -670 Permit Inspection Request Line (206) 431 -2451 ymt0 -1y1 Project: blPAS 1.4 Type of Inspection: w1NAL Address: (2..2 7 Psr n1 0 osJ a. h IL €._ Date Called: - Special Instructions: Date Wanted: 12- 269 -10 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4,.) &_ I • /'L —z, —t0 SPECTION FEE R ' U RED. Prio /o next,inspection. fee must be at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. ipzr• .r �. •_ - - r_ fir. rtc -a.- ."v recTs. yr tit P• z- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT (IA - tcs9 CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: S 44 AS-rA P1F LIP itA40 C Type of Inspection: n N401 1-- Address: 1221 165-4 tfOtfia ct. _c)14 E__ Date Called: • Special Instructions: - • .- . . . Date Wanted: M-2C)-10 Cr......rm p.m. Requester: Phone No: D4942--.S10 -- 11-1/ 3 ElApproved per applicable codes. ca.! orrectionsrequired prior to approval. COMMENTS: 0 lir tz.A.Pdtbci kh-If4 • %qt% ECTION FEE EQUIED.Priorto n tinspection. fee must be 6300 Southcenter. Blvd.. Suite 100. Call tO schedule reinSpection. ••■ •.• ekt ece,kt • - 6 yitie:WW 4N, .• • .:rgegefaiii./...= rtICLIMODFOSS. 1• INSPECTION RECORD... a`p Retain a copy with permit INS ION ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 02 6300 Southcenter Blvd., #100,, Tukwila. WA 98188 • (206) 431 -3670 Permit-Inspection Request Lune (206) 431 -2451 . • Project: -S 4 ASIT"A- Type of Inspection: 171 N A - Address: 1 2-11 .t Jj R_ S' l ' _ Date Called: Special Instructions: . Date Wanted: t- Y 2> t a.m. Requester: Phon//e��No: •45 ❑ Approved per applicable codes. LJCorrections required prior to approval. COMMENTS: P• 61441.A. P\trt*t0. f *ye&4 • e or: Date: INSPECTION FEE R QUIRED. Pric r to next inspection..fee must be p id at 6300 Southcent r Blvd:, Suite 100. Call to schedule reinspection. 1 M:,'¢`.1: YTS. • b , - — . . • sa • • 1. • - yeast= _tiP•- ° 4�' .d ►rt.L- M .rte � } EQUIP You wiH receive an invoice from Cali to sc tedule a re%ape on. Word/Inspection Record Form. 3/06 T.F.D. Form F.P. 113 Needs Shift Inspection: Sims; Fire farm: Mo Pre- Fite P'ertxtits: pcupency Type: EQUIP You wiH receive an invoice from Cali to sc tedule a re%ape on. Word/Inspection Record Form. 3/06 T.F.D. Form F.P. 113 REZNOR PILE COPY NEW!! • � 0S CODE FOR R ODE COMPLIANCE NOV 02010 VOET1 Power Vented Model UDAP I 157 City of Tukwila BUILDING DIVISION RECEIVED Low Static NOV 15 2010 PERMIT CENTER Axial Fan Unit Heaters for Residential and Commercial /Industrial Use CAS UNIT I-4E,4TER 4NG(NG DETAIL WEATHER CAP ROUND DUCT TYPE DOUBLE WALL GAS EAL AROUND SEAL WITH WEATHER STORM COLLAR AND BUILDING ROOF —_ PROVIDE BETWEEN IN SLEEVE ROOF lir AND I" AIR FLUE AND ROOF (2) THREADED FOR PROPER 3/8 "7 MINIMUM. SPANNED SEISMIC TO RODS SIZED SUPPORt- THRU UNISTRUT BETWEEN TRUSSES BRACING BUILDING STRUCTURE. FIXED DOWNTURN ADJUSTABLE LOUVERS. FROM EACH CORNER LOUVE --i4-, VERTIG -,�' II 3 -BIRD PROOF B (METALBESTOS) VENT TNRU ROOF STORM COLLAR GAP PENETRATION. BUILDING I' I TIGHT SEALANT CONE FLASHING �— 416N \ X .■12 Al& .W:/. TRUSS t 1 / 24 GAUGE MINIMUM �/ GALVANIZED FLUE PIPE. UNIT $ >:0. HEATER"' Npr .W2 AIR FLOW >WITM __ COORDINATE MOUNTING HEIGHT OWNER AND MANUFACTURERS INSTALLATION INSTRUCTIONS. EA WITHu dia q" REZNOR //-7/-( Z_ Model UDAP Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial /Industrial Use CGA 2.6b ANSI Z83.8b CSA International Requirement 10.96 U.S. - Sizes 30 -125 DESCRIPTION Reznor® V 3 Series Model UDAP gas -fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30 -125 are approved for residential application. All sizes are approved for commercial /industrial installations. Model UDAP heaters are designed for 82 -83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards As- sociation (CSA). Reznor® V 3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less vis- ible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30 -125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connect- ing control wiring easy with no panels to remove. The addi- tion of a "G" terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connec- tion. The preeminent new internal feature is the T -coRE2 ® heat exchanger and single burner combustion system. Other standard features include a single -stage gas valve, multi -try direct spark ignition with 100% lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and mo- tor assembly, and a high temperature limit control. Sizes 30- 125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic in- dicator lights to identify abnormalities in control functions. The new V3 Series unit heaters are designed to pro- vide all the features you expect in a Reznor heater plus im- proved efficiency, easier installation, and a new look - both inside and out. Form RZ -NA C- UDAP /S, Page 10 STANDARD FEATURES • Sizes 30 -125 certified for residential heating application • Sizes 30-400 certified for commercial /industrial heating application • 82 -83% Thermal efficient -- TOP in its class! • 50 -60 °F Rise range • NEW T -coRE2 ® design titanium stabilized aluminized steel heat exchanger (patent pending) • NEWT coRE2® design single burner combustion system including a one -piece burner assembly (patent pending) • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload protection • Transformer for 24 -volt controls • Integrated circuit board with diagnostic indicator lights • Fan relay (included on the circuit board) • Multi -try direct spark ignition with 100% lockout • Natural or propane single -stage gas valve (field adjustable for operation to 9,000 ft elevation) • Vibration /noise isolated fan and venter motors - designed for low noise operation • 2 -pt and 4 -pt Suspension - standard on all sizes • External terminal strip for 24 -volt wiring • External gas connection • Full fan guard - engineered for safety • Improved cabinet design with less visible hardware and a NEW Reznor appearance OPTIONAL FEATURES - FACTORY INSTALLED • Two -stage natural or propane gas valve • 409 or 316 Stainless steel heat exchangers • 208 or 230 Single phase voltage • Totally enclosed fan motor (115V only) • Common venting with other gravity vented Category I appliance(s) ACCESSORIES - FIELD INSTALLED • Vent cap • Thermostat • Thermostat guard with locking cover • Vertical louvers - new design • Downtum nozzle kits - new design • Gas conversion kits (natural and propane) • Master /Slave controls for zoning up to six units • Ceiling suspension kit - Sizes 30 -125 • Hanger kits for 1" pipe • Stepdown transformer (for 230/3 and 460/3 supply voltage) • Manual shutoff valves v Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS P and O- Hanger Dimensions for 4 -pt Suspension M and N - Hanger Dimensions for both 2 -pt and 4 -pt Suspension N -► M 1 P 1 1 TOP VIEW R - Hanger Dimension for 2 -pt Suspension 3/8 " -16 Female Thread - all suspension points 1 Form RZ -NA C- UDAPIS, Page 12 Thermostat Connection (30 -125 Vertical; 150 -400 Horizontal) Combustion Air Inlet REAR VIEW \,‘ Y Line Voltage Inlet (connects at circuit board) I( H —► External Gas Connection F E r Vent Connection (see Technical Data for size) RIGHT SIDE VIEW (Access Panel) u MODEL UDAP TECHNICAL DATA- Sizes 30 -125 Size 150 30 45 60 75 100 125 Input Heating Capacity BTUH 30,000 45,000 60,000 75,000 105,000 120,000 kw/h 8.8 13.2 17.6 22.0 30.8 352 Thermal Efficiency( %) 82 83 83 83 83 83 Output Heating Capacity" BTUH 24,600 37,350 49,800 62,250 87,150 99,600 kw/h 7.2 11.0 14.6 18.3 25.6 292 Gas Connection (inches) 8 Natural 1/2 1/2 1/2 1/2 1/2 1/2 Propane 1/2 1/2 1/2 1/2 1/2 1/2 Vent Connection Size c (inches diameter) 4 4 4 4 4 4 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 Full Load.Amps (115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 Mwdmum Over Current Protection (115V) ° 15 15 15 15 15 15 Normal Power Consumption (watts) 109 155 155 217 276 354 Discharge Air Temperature Rise ( °F) 50 55 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 M3 /minute 12.9 17.8 21.8 27.5 36.7 45.9 Discharge Air Opening Area ft2 0.96 0.96 1.25 1.25 2.01 2.01 M2 0.09 0.09 0.12 0.12 0.19 0.19 Output Velocity FPM 475 656 616 770 668 763 M/minute 145 200 188 238 196 245 Fan Motor HP a Open 0.02 0.03 0.03 0.06 1/30 1/20 Enclosed N.A N.A. N.A. N.A 1/4 1/4 Fan Motor RPM 1550 1550 1550 1550 1050 1050 Fan Diameter (inches) 10 10 12 12 16 16 ApproAmate Net Weight Ibs 54 59 67 72 96 101 kg 24 27 30 33 44 46 Appro)dmate Ship Weight Ibs 61 66 74 79 118 123 kg 27 30 33 36 54 56 MODEL UDAP TECHNICAL DATA Sizes 150 - 400 Size 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kw/h 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency( %) 83 83 83 83 83 83 83 83 Output Heating CapacityA BTUH 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 kw/h 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection (inches) B Natural 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Propane 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size C (inches diameter) 5 5 5 5 5 6 6 6 Control Amps (24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Mips (115 volt) 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection (115V) 0 15 15 15 15 15 20 20 20 Normal Power Consumption (watts) 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise ( °F) 60 60 60 60 60 60 60 60 Air Volume CFM 1921 2242 2562 2882 3202 3843 4483 5123 M3 /minute 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening Area ft2 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 M2 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 752 877 1003 820 911 802 936 1069 M/minute 229 267 306 250 278 244 285 326 Fan Motor HP E Open 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Enclosed 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter (inches) 18 18 18 20 20 24 24 24 Approximate Net Weight lbs 172 187 187 203 215 269 294 306 kg 78 85 85 92 98 122 133 139 Approbmate Ship Weight lbs 204 219 219 245 257 321 346 358 kg 93 100 100 111 117 146 157 163 A CSA ratings for altitudes to 2000 ft. B Size shown is for gas connection to a single -stage gas valve, not supply line size. C Smaller and /or larger vent pipe diameters may be permissible; refer to the Venting Installation Manual for Power Vented Units. D MOPD = 2.25 x (largest motor FLA) + smallest motor FLA Answer is rounded to the nearest commercially available circuit breaker. e All other information is this table is based on a heater equipped with a standard 115 volt open fan motor. Form RZ -NA C- UDAP /S, Page 11 MODEL UDAP DIMENSIONS (inches *1/16 Size A B C D E F G H J K M N P Q R 30,45 12 -1/8 26 -5/8 10 13 -13/16 26 21 -9/16 5 -3/16 6 -1/2 2 -11/16 3 -7/8 17 -3/8 11/16 4 -5/16 13 9 -9/16 60 15 -1/8 26 -5/8 13 13 -13/16 27 21 -9/16 7-7/8 6 -1/2 5 -1/2 3 -7/8 17 -3/8 11/16 4 -5/16 13 10 -1/2 75 15 -1/8 26 -5/8 13 13 -13/16 27 -5/8 21 -9/16 7 -7/8 6 -1/2 5-1/2 3 -7/8 17 -3/8 11/16 4 -5/16 13 10 -1/2 100 23 -1/8 26 -5/8 21 13 -13/16 28 -5/8 21 -9/16 14 -1/2 6-1/2 8 -3/4 3 -7/8 17 -3/8 11/16 4 -5/16 13 10 -1/2 125 23 -1/8 26 -5/8 21 13 -13/16 29 -3/8 21 -9/16 14 -1/2 6 -1/2 8 -3/4 3 -7/8 17 -3/8 11/16 4 -5/16 13 10 -1/2 150, 175, 20-1/8 38 -3/16 16 23 42 35 -3/8 8 -1/2 8 -1/4 5 -7/16 6 -1/2 25 -11/16 1 -3/8 8 -3/16 22 -3/16 16 -3/8 200 225' 250 26 -1/8 38 -3/16 22 23 42 35 -3/8 13 -1/16 8 -13/16 9 6 -1/2 25 -11/16 1 -3/8 8 -3/16 22 -3/16 15 -5/8 300, 350, 34 -1/8 41 30 23 42 35 -3/8 17 -1/16 9 11 -13/16 7 -5/16 27 -11/16 1 -3/8 8 -3/16 22 -3/16 16 -3/16 400 MODEL UDAP DIMENSIONS (mm±2 Size A B C D E F G H J K M N P O inches 30,45 308 676 254 351 660 548 132 165 68 98 441 17 110 0 243 60 384 676 330 351 686 548 200 165 140 98 441 17 110 330 267 75 384 676 330 351 702 548 200 165 140 98 — 17 110 330 267 100 587 676 533 351 727 548 368 165 222 441 17 110 330 267 125 587 676 533 351 746 548 368 165 222 98 441 17 110 330 267 150, 175, 511 970 406 584 1067 899 216 210 138 165 652 35 208 564 416 200 225' 250 664 970 559 584 1067 899 332 224 229 165 652 35 208 564 397 300, 350, 867 1041 62 584 1067 899 433 229 300 186 703 35 208 564 411 400 CLEARANCES Size Top Flue Connector Access Panel Non - Access Side Bottom* Rear inches rrrn inches rrm inches rrm inches rrrn inches rrrn inches rrrn 30 -125 1 25 6 152 18 457 1 25 1 25 18 457 150 -400 4 102 6 152 18 457 2 51 1 25 18 457 *Suspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor. Form RZ -NA C- UDAP /S, Page 13 SAMPLE SPECIFICATIONS GAS - FIRED, POWER VENTED UNIT HEATERS Provide (82 %, 83 %) high - efficiency, power vented, gas -fired unit heaters manufactured as Reznor® brand units designed for use in building areas where higher reliability is required and venting is either vertical or horizontal. Model UDAP Each of the 14 sizes in the Model UDAP series shall be equipped for use with (natural) (propane) gas. Gas connection shall be external to the cabinet. Heat Exchanger The heater shall be equipped with a multicell, 4 pass serpen- tine style steel heat exchanger. Heat exchanger tubes shall be press fabricated of (titanium stabilized, corrosion resistant aluminized steel) (409 stainless steel) (316 stainless steel). All heat exchangers shall be fabricated with no welding or brazing, only tool pressed mechanical joints. All heat ex- changer cells shall be designed with an aerodynamic cross section to provide maximum airflow. Burner The units shall incorporate a single, one piece bumer assem- bly with a single orifice. The bumer shall have a continuous wound close pressed stainless steel ribbon separating the flame from the bumer interior. All units shall have a single venturi tube and orifice supplying fuel to a one -piece bumer housing. Each heat exchanger cell shall use balanced draft induction to maintain optimum flame control. Controls Controls shall include a (single- stage) (two - stage) gas valve; direct spark multi -try ignition with electronic flame supervision with 100% lockout integrally controlled via a printed circuit control board. The control board shall also incorporate diagnostic lights, DIP switches for fan overrun settings, and a relay for fan only operation. All units shall be equipped with a safety limit switch. All controls shall be enclosed in the unit housing to protect them from accidental damage that could be caused by factors in the building that would adversely affect external controls. Combustion Air and Venting The unit shall have a factory- installed power venter device to draw combustion air through an inlet in the rear of the cabinet. The combustion air /venting system shall include a vibration isolated power venter motor and wheel assembly and a combustion air pressure switch. Unit Sizes 30 -125 shall include a flame rollout switch. (The unit shall be equipped with an approved common vent option to allow venting with another gravity vented Category I gas appliance). (A vent cap shall be available.) Electrical Operation shall be controlled by an integrated circuit board that includes LED diagnostic indicator lights. Supply voltage connections are made at the circuit board. 24 -volt control connections shall be made on an externally mounted terminal strip with connections (W1, W2, R, and G). All internal wiring, both line and control voltages, shall be terminated by insu- lated terminal connectors to minimize shock hazard during service. Form RZ -NA C- UDAP /S, Page 14 Each unit shall be equipped for use with (115/1) (208/1) (230/ 1) volt power supply. (Stepdown transformers shall be available to be field installed for use with (230/3) (460/3) volt power supply.) Cabinet The cabinet shall be low profile with a pre -coat or powdercoat RAL 1001 white paint finish. Finish shall be a minimum 80 gloss on G30 galvanized steel. The cabinet shall be con- structed so that screws are not visible from the bottom, front, or sides, except for service panel and accessories. Unit construction shall incorporate a beveled front comer on control side for additional cabinet rigidity. All units shall be manufactured with a tooled drawn supply air orifice on the rear panel to reduce fan inlet noise. The unit shall be designed for ceiling suspension featuring 3/8 " -16 female threads (hanger kits for 1" pipe) at both 2 -point and 4 -point locations with no additional adapter kits. (Hanger kit for ceiling mounting shall be available for Sizes 30 -125.) The cabinet shall be equipped with RAL 3005 burgundy painted, roll - formed horizontal louvers. Louvers shall be spring held and adjustable for directing airflow. (Vertical louvers) (downturn nozzles) (downturn nozzles with vertical louvers) shall be available. The cabinet shall be equipped with a full safety fan guard with no more than'/ inch grill spacing on Sizes 30-125 or no more than 1 inch on Sizes 150 -400. The (open dripproof) (enclosed) motor and fan assembly shall be resiliently mounted to the cabinet to reduce vibration and noise. The unit shall be designed with a full opening service access panel complete with screw closure attachment and lifting handle for removal. All components in the gas train, all standard electrical controls, and the power venter shall be within the service compartment. Minimum top clearance from combustibles shall be 1" for Sizes 30-125 and 4" for Sizes 150 -400. Minimum bottom clearance from combustibles shall be 1" for all sizes. Minimum clearance from combustibles on non - service side shall be 1" for Sizes 30 -125 and 2" for Sizes 150 -400. Certifications Model sizes 30, 45, 60, 75, 100 and 125 MBH shall be certified to CSA International Requirement 10 -96 U.S. for RESIDENTIAL INSTALLATION. All sizes shall be design certified by the Canadian Standards Association to ANSI Z83.8b and CGA 2.6b for commercial /industrial installation. Units shall be manufactured in an ISO 9002 certified facility. Manufacturer must have a minimum of 50 years experience in the manufacture of gas fired unit heaters. Type CRBA Belt Drive Centrifugal Power Roof Ventilators INDUSTRIES DIVISION AMERICAN COOLAIR CORPORATION P.O. Box 2300 Jacksonville, Florida 32203 Phone: (904) 389-3646 Fax: (904) 387-3449 • (904) 381 -7560 E -mail: fans @coolair.com Internet: www.coolair.com Standard Fan Features • Non -overloading aluminum wheel computer balanced. • Force ventilated motor compartment isolated from airstream. • Variable pitch motor pulley. • Vibration isolators on drive frame. • Weatherproof spun aluminum housin • NEMA Standard open drip -proof mot • Overlapping wheeUnlet venturi. • Heavy duty self- aligning pillow -block bearings with cast iron housing. • AMCA label for air and sound. • Polypropylene birdscreen. D H O.D. 1 61r 16 /r J I.D. 1 1 8' STD. HEIGHT 1' Sheet ( of / 11/r THICK INSULATION r--- ESQ. Optional Features • UL Label for Standard 705. • Disconnect switch (loose or factory mounted and wired). Backdraft damper. Roof curb (damper shelf optional). • Epoxy coating. > • • 9. ors. FSQ. I �� G SQ. A SQ. I.D. 2' SIZE Ventilator Dimensions Roof Curb and Damper Dimensions A B C D E F G H J 06-10 18 231/8 201/2 241/2 121/2 10 111/4 161/2 131/4 12 -15 23 28 5/8 22 1/2 29 1/2 17 1/2 15 16 1/4 21 1/2 18 1/4 16-20 30 35 1/2 24 5/8 36 1/2 24 1/2 22 23 1/4 28 1/2 25 1/4 24 34 42 3/4 32 1/2 40 1/2 28 1/2 26 27 1/4 32 1/2 29 1/4 30 40 50 1/4 36 3/4 46 1/2 34 1/2 32 33 1/4 38 1/2 35 1/4 36 46 61 3/4 44 1/4 52 1/2 40 1/2 38 39 1/4 44 1/2 41 1/4 44 56 71 1/4 49 62 1/2 50 1/2 48 49 1/4 54 1/2 51 1/4 52 65 83 3/4 55 1/2 71 1/2 59 1/2 57 _ 58 1/4 63 1/2 60 1/4 Specifications ❑ Check here for UL 705. FAN DATA MOTOR DATA Dimensions In Inches FAN NO. QTY. MODEL NO. CFM SP RPM SONES HP RPM VOLTAGE PH HZ ENCLOSURE ACCESSORIES AND REMARKS .6a-•2 Z CR51 / Z /'f(O /g I /O.2. /os //5— (Go cvti^6 9'- Spp PROJECT LOCATION ENGINEER Xr CONTRACTOR . Iv. SUBMITTED BY \ //A— APPROVED BY 7,c7• DATE //- 2 ^l0 DATE / e. lf7 EFFECTIVE MAY 1, 2003 SHIPPING WEIGHTS AND DIMENSIONS ILG INDUSTRIES FORM 705 -23 -3 (5 -03) PAGE 10 OF 20 CRBA MODEL HP BOX / UPS / SIZE WGT. CUBIC CRATE TRUCK (INCHES) (LBS) FEET CRBA06G 1/4 BOX TRUCK 26X26X27 CRBA08G 1/4 BOX TRUCK 26X26X27 CRBAIOG 1/4 BOX TRUCK 26X26X27 CRBAI2G 1/4 BOX TRUCK 34X34X32 CRBAI2H 1/3 BOX TRUCK 34X34X32 CRBAI2J 1/2 BOX TRUCK 34X34X32 CRBAI2K 3/4 BOX TRUCK 34X34X32 CRBAI3G 1/4 BOX TRUCK 34X34X32 CRBAI3H 1/3 BOX TRUCK 34X34X32 CRBAI3J 1/2 BOX TRUCK 34X34X32 CRBAI3K 3/4 BOX TRUCK 34X34X32 CRBAISG 1/4 BOX TRUCK 34X34X32 CRBAI5H 1/3 BOX TRUCK 34X34X32 CRBAI5J 1/2 BOX TRUCK 34X34X32 CRBA15K 3/4 BOX TRUCK 34X34X32 CRBAI5L 1.0 BOX TRUCK 34X34X32 CRBAI6G 1/4 CRATE TRUCK 42X42X34 CRBAI6H 1/3 CRATE TRUCK 42X42X34 CRBAI6J 1/2 CRATE TRUCK 42X42X34 CRBAI6K 3/4 CRATE TRUCK 42X42X34 CRBAI6L 1 CRATE TRUCK 42X42X34 CRBAI6M 11/2 CRATE TRUCK 42X42X34 CRBAI8H 1/3 CRATE TRUCK 42X42X34 CRBAI8J 1/2 CRATE TRUCK 42X42X34 CRBAI8K 3/4 CRATE TRUCK 42X42X34 CRBAI8L 1 CRATE TRUCK 42X42X34 CRBA18M 11/2 CRATE TRUCK 42X42X34 CRBAI8N 2 CRATE TRUCK 42X42X34 CRBA20J 1/2 CRATE TRUCK 42X42X34 CRBA20K 3/4 CRATE TRUCK 42X42X34 CRBA2OL 1 CRATE TRUCK 42X42X34 CRBA2OM 11/2 CRATE TRUCK 42X42X34 CRBA20N 2 CRATE TRUCK 42X42X34 88 90 91 95 98 103 95 98 102 107 92 95 98 102 106 186 188 192 194 197 202 161 165 169 174 183 188 194 196 201 206 213 11 11 11 22 22 22 22 22 22 22 22 22 22 22 22 22 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 • 1 PE 3�� As CPY � ,� �..pl $ -� P i �<. }7. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -159 PROJECT NAME: SHASTA BEVERAGES SITE ADDRESS: 1227 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # DATE: 11 -15 -10 Response to Correction Letter # Revision # After Permit Issued DEPART ENTS: ,�� S C. 0 Wt c `` � ullding ivislon �� ire Prevention Lim Public Works ❑ Structural ❑ Planning Division Permit Coordinator Fri DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -16 -10 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) DUE DATE: 12 -14 -10 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople liter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company UNIVERSAL REFRIGERATION INC 2539395501 Po Box 614 Auburn WA 980710614 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600599723 Active UNIVERI159RF Construction Contractor 12/6/1985 4/1/2012 Commercial/Industrial/ Refrig Unused Business Owner Information Name Role Effective Date Expiration Date RAEDER, STEVEN C Cancel Date 01/01/1980 Amount VERNON, GUY E 25 01/01/1980 01/01/1980 JACKSON, SHELDON G 04/01/2011 01/01/1980 01/01/1980 OSENBAUGH, CHARLES R 03/02/2010 01/01/1980 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 AMERICAN STATES INS CO EX903622 12/06/2001 Until Cancelled $6,000.00 03/18/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 25 AMERICAN STATES INS CO 01CG7497626 04/01/2010 04/01/2011 $1,000,000.00 03/02/2010 24 AMERICAN STATES INS CO 01CG7497625 04/01/2009 04/01/2010 $1,000,000.00 03/09/2009 23 AMERICAN STATES INS CO 01CG7497624 04/01/2008 04/01/2009 $1,000,000.00 03/11/2008 22 FIRST NAT'LINS CO OF AMERICA 01CG7497623 04/01/2007 04/01/2008 $1,000,000.00 03/01/2007 21 FIRST NATIONAL INS. CO. OF AME 01CG7497622 04/01/2006 04/01/2007 $1,000,000.00 03/13/2006 20 FIRST NATIONAL INSURANCE CO OF 01CG749762 04/01/2006 04/01/2007 $1,000,000.00 03/10/2006 19 AMERICAN CAS INS CO C2026115262 04/01/2005 04/01/2006 $1,000,000.00 03/23/2005 18 AMERICAN CAS CO OF READING C2026115262 04/01/2004 04/01/2005 $1,000,000.00 04/12/2004 17 TRANSPORTATION INS CO C2026115262 04/01/2004 04/01/2005 $1,000,000.00 03/15/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 12/02/2010 PENDING CITY APPROVAL, SEPARATE PERMIT REQUIRED FOR: Ci Mechanical lectricat !Plumbing Comas Piping City of Tukwila MILTING DIVISION REVISIONS No changes shall be made to the scope • of work without prior approval of Tukwiia Building Division. NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71 ` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , : FAN NV,4C 4EVIATIONS 1 STI UT AFF ABOVE FINISHED FLOOR BPP BACKDRAPt DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE DB DECIBEL DEG DEGREE DI-1 DUCT NEATER DN POUIN EA EXHAUST AIR EER ENERGY EFFICIENCY RATIO EG EXHAUST GRILLE ESP EXTERNAL STATIC PRESSURE EW7 ENTERING WATER TEMPERATURE EXH EXHAUST FCU FAN COIL UNIT FD FIRE PAMPER, FLOOR DRAIN FOIC FURNISHED BY OWNER INST. SY CONTRACTOR FPM FEET PER MINUTE FSD FIRE AND SMOKE PAMPER GA GAUGE GF GAS FURNACE GPM GALLONS PER MINUTE GRID GRILLE, REGISTER, DIFFUSER CsWB GYPSUM UJALL60ARP HP HORSEPOWER, 1-1EA7 PUMP HVAC HEATING, VENTILATING AND AIR CONDITIONING 1-1VAC AREVI4T1ONS ID SEPARATE PERMIT REQUIRED FOR: Ci Mechanical lectricat !Plumbing Comas Piping City of Tukwila MILTING DIVISION REVISIONS No changes shall be made to the scope • of work without prior approval of Tukwiia Building Division. NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71 ` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , : FAN 054 1D 1 STI UT 1-1VAC AREVI4T1ONS ID SECTION 302.3.53 WSIAQC - OUTDOOR AIR SHALL 5E DISTRIBUTED TO EACH ROOM /AREA. WHERE SUPPLY IS SEPARATED FROM EXHAUST POINTS 5Y DOORS, PROVISIONS SHALL 5E MADE TO ENSURE AIRFLOW 5Y UNDERCUTTING DOORS, TRANSFER GRILLES, OR SIMILAR MEANS. DOORS SHALL 5E UNDERCUT A MINIMUM 1/2" ABOVE FLOOR COVERING (SEE BELOW). CFM THROUGH DOOR -.NO TRANSFER GRILLE ID IRH KUJ MBH MCD NC NIC NTS 05D OC OD 05A PD . RPM RA RAG SA SG SP SSG TED TG TYP VAV VFD VTR VVT INSIDE DIMENSION INFRARED HEATER KILOWATT THOUSAND BTU PER HOUR MOTORIZED CONTROL DAMPER NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OPPOSED SLADE DAMPER ON CENTER OUTSIDE DIMENSION OR DIAMETER OUTSIDE AIR PRESSURE DROP REVOLUTIONS PER MINUTE RETURN AIR RETURN AIR GRILLE SUPPLY AIR SUPPLY GRILLE STATIC PRESSURE SIDEWALL SUPPLY GRILLE TO 5E DETERMINED TRANSFER GRILLE TYPICAL VARIABLE AIR VOLUME VARIABLE FREQUENCY DRIVE VENT TO ROOF VARIABLE VOLUME AND TEMPERATURE ACLU= -� � I SEPARATE PERMIT REQUIRED FOR: Ci Mechanical lectricat !Plumbing Comas Piping City of Tukwila MILTING DIVISION REVISIONS No changes shall be made to the scope • of work without prior approval of Tukwiia Building Division. NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71 ` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , : FAN 054 1D 1 STI UT 1 ON /NON - ED UCTE r) RETURN ID SECTION 302.3.53 WSIAQC - OUTDOOR AIR SHALL 5E DISTRIBUTED TO EACH ROOM /AREA. WHERE SUPPLY IS SEPARATED FROM EXHAUST POINTS 5Y DOORS, PROVISIONS SHALL 5E MADE TO ENSURE AIRFLOW 5Y UNDERCUTTING DOORS, TRANSFER GRILLES, OR SIMILAR MEANS. DOORS SHALL 5E UNDERCUT A MINIMUM 1/2" ABOVE FLOOR COVERING (SEE BELOW). CFM THROUGH DOOR -.NO TRANSFER GRILLE FIG. 15 SECTION 25.19 1991 ASHRAE b CFM ACLU= -� � I a +b +c +d L. 600 _ - A P = 30 inches I 4 Assume a, b, c = .1 inches c d = .5 inches ACW = 2 inches I Average door 1 EF -1,2 ILG m `-- ACLU .2 inches ,2 avg. crack width (ACLU) d Now correlate to pressure differential of NOT acceptable LP = .15 inches H2O ROOMS SUPPLIED WITH l.55 15 CFM = CFM CFM +.683 X400 CFM OR MORE (.3 01 = REQUIRE TRANSFER GRILLES (AP =.151) = 600x.68 = 408CFM CV SEPARATE PERMIT REQUIRED FOR: Ci Mechanical lectricat !Plumbing Comas Piping City of Tukwila MILTING DIVISION REVISIONS No changes shall be made to the scope • of work without prior approval of Tukwiia Building Division. NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71 ` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , : FAN ID ULF 501117 ID BRAND NAME MODEL NUMBER CFM SP HP /AMP FLOW V /PH SOUND RATING DUCT LOCATION EF -1,2 ILG CR5Al2 -1/4 1,400 .125 1/4 CV 115/14) 10.2 14x14 511 WAREHOUSE FILE COPY Permit No. Plan review approval is subject to errors and omissions. Ap roval of construction documents does not authorize 14c v olation of any adopted code or ordinance. Receipt o' approved Field Copy and con o is acknowledged: GAS UNIT kF4THR SCkEULLE ID BRAND NAME MODEL NUMBER CFM Btuh INPUT Btuh OUTPUT EFFICIENCY GAS GAS CONNECTION V OUT OUTLET V /PH FLA WT. UH -1,2 REZNOR UDAP -200 2,562 200,000 166,000 83% 1/2 "4) 5 "• 120/14) 5 181 LBS. NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. By Date: I 1c. ity Of Tiukwila BUILDING DIVISION --0,2,,„,octaii-- Th. b.e set Log-gt ax/.0.cAkr, ■t « AG 1 T mou.Nf rl no 1 owev• -Puts" �'ke htaf ;; to REVIEWED FOR CODE COMPLIANCE APDKOVED NUV 3 0 2010 �J ')1( City of Tukwila BUILDING DIVISION 1 --1VAC LEGENED 1. DUCT INSULATION SHALL MEET INLINE EXHAUST FAN(5) 0 i 2. SMOKE DETECTOR(S) INSTALLED IN i SECTION 606 OF THE 2010 IMC. INVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNiT UPON ACTIVATION AND, A ROOFTOP EXHAUST FAN INITIATED AT THE FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 6062.1. 3. DUCTWORK- MAINTRUNK IS R -42 IN CONDITIONED SPACES AND R -8 IN UNCONDITIONED SPACES AS PER THE IiiSiDEWALL 4. ALL SINGLE PACKAGE HVAC UNITS EXHAUST FAN ERS PER MANUFACTURER'S INSTALL- n SECTION 403, CHAPTER 6, AND SHALL VAV FAN 5OX C 5. EQUIPMENT INSTALLATION 1 INSPECTIONS. 6. ALL HVAC EQUIPMENT TO BE LABELED -TO THE SPACE SERVED. 1. DUCTS TO 5E SUPPORTED AT EACH DIRECTION CHANGE - VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" CEILING EXHAUST FAN TRAPEZE SUPPORT. r AND SEVEN DAY TYPE, WITH 5 DEGREE DEADBAND. GAS METER COMPLETE WHEN ALL SECTIONS OF ZD12 'PHIS SHALL INCLUDE AS -BUILT DRAW- VVT DAMPER SYSTEM BALANCE REPORT, AND A COMMISSIONING REPORT. 10.DUCT SEALING SHALL MEET REQUIRE - 0 THERMOSTAT AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL 5E SEALED IN ACCORDANCE WITH T -SAR SUPPLY DIFFUSER ING IS AS FOLLOWS: L STATIC PRESSURE: 1/2" TO 2"; SEAL TRANSVERSE JOINTS. 2. STATIC PRESSURE 2: 2" TO 3 "; SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. 3. STATIC PRESSURE: ABOVE 3 "; SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS. 11. NREC FORMS, DUCTING PLANS T -EAR RETURN GRILLE VIAQ INFORMATION IS REQUIRED ALONG WITH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. 12. PIPING INSULATION SHALL MEET THE REQUIREMENTS OF 1415 OF THE WSEC: TABLE 14-8 MINIMUM PIPE INSULATION (INCHES) FLUID DESIGN INSULATION CONDUCTMiY INAL PIPE DIAMETER IN.) OPERATING TEMP. GONDUCTMiY RANGE HARDLID SUPPLY DIFFUSER RUNOUTS' // > 4 TO 8 > 8 RANGE 'F Btu- in/h -FT2- F I TEMP. 'F UP TO 2 J HARDLID RETURN GRILLE J HEATING SYSTBAS (STEM, CONDENSATE AND HOT WATER) NOMINAL INSULATION THICKNESS ABOVE 350 CEILING RADIATION DAMPER ABOVE DIFFUSER 250 1.5 2.5 1 3.0 MI 3.5 251 -350 0.29 -0.31 200 1.5 2.0 2.5 2.5 3.5 CEILING RADIATION DAMPER ABOVE GRILLE 201 -250 0.27 -0.30 150 1 i 1.5 L_J 2.0 FD ►- FIRE DAMPER FSD FIRE SMOKE DAMPER 125 VOLUME DAMPER q 6 1.5 SDI- SMOKE DETECTOR -"......w....,- •.„ FLEXIBLE DUCT SA /RA 0.24-0.28 0.24 -0.28 ROUND DUCT UP 1.5 1.0 1.0 1 1 ROUND DUCT DOWN 1.5 ESTIC WATER ACCESS PANEL I 100 1 0.5 1 1.0 I 1.0 I 1.5 1 1.5 1 1.5 A P (CH X55 0.23-021 40xigivier?4,) SUPPLY AIR DIFFUSER 0.5 RETURN AIR GRILLE RAG\ /24600 Cx24 FM -12 � ` ( RTU -1 ) ROOFTOP UNIT 75 . EXHAUST FAN ( EF -1 ) I 1.5 ( SF -1 SUPPLY FAN 11.0 1.5 ( UH -1 ) UNIT HEATER CONDENSING UNiT ( CU -1 ) HP -1 ) HEAT PUMP AC -1 ) AIR CONDITIONING UNIT AIR HANDLING UNIT ( AHU -1 ) ( IR1-1-1 ) INFRARED HEATER --0,2,,„,octaii-- Th. b.e set Log-gt ax/.0.cAkr, ■t « AG 1 T mou.Nf rl no 1 owev• -Puts" �'ke htaf ;; to REVIEWED FOR CODE COMPLIANCE APDKOVED NUV 3 0 2010 �J ')1( City of Tukwila BUILDING DIVISION CONTRACTOR'S LICENSE NUMBER: INNER 1591* AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141 SEATTLE: (253) 839 -2126 FAX: (283) 135 -3432 P.O. Box 614 - AUBURN, WASHINGTON 98071 @ UNIVERSAL REFRIGERATION DRAWING -200t PRINT /PLOT DATE: I-1VAC NOTES 1. DUCT INSULATION SHALL MEET REQUIREMENTS OF SECTION 14142 OF THE 2006 WSEC AND TABLE 14 -5. 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS AS PER SECTION 606 OF THE 2010 IMC. INVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNiT UPON ACTIVATION AND, A "SUPERVISORY" ZONE SHALL 5E INITIATED AT THE FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 6062.1. 3. DUCTWORK- MAINTRUNK IS R -42 IN CONDITIONED SPACES AND R -8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL 5E INSTALLED WITH ECONOMIZ- ERS PER MANUFACTURER'S INSTALL- ATION INSTRUCTIONS PER I.M.C. 2010, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2006, SECTION 1413. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO 5E ON SITE FOR INSPECTIONS. 6. ALL HVAC EQUIPMENT TO BE LABELED -TO THE SPACE SERVED. 1. DUCTS TO 5E SUPPORTED AT EACH DIRECTION CHANGE - VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" -MAX. WITH STRAP, OR 8' -0" MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO HAVE NIGHT SETBACK AND SEVEN DAY TYPE, WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL. 5E COMPLETE WHEN ALL SECTIONS OF 1416 WSEC HAVE BEEN SATISFIED. 'PHIS SHALL INCLUDE AS -BUILT DRAW- INGS, SUBMITTALS, 04M MANUALS, SYSTEM BALANCE REPORT, AND A COMMISSIONING REPORT. 10.DUCT SEALING SHALL MEET REQUIRE - MENTS OF WSEC 1414.1. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL 5E SEALED IN ACCORDANCE WITH STANDARD R8-18. EXTENT OF SEAL- ING IS AS FOLLOWS: L STATIC PRESSURE: 1/2" TO 2"; SEAL TRANSVERSE JOINTS. 2. STATIC PRESSURE 2: 2" TO 3 "; SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. 3. STATIC PRESSURE: ABOVE 3 "; SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS. 11. NREC FORMS, DUCTING PLANS (BALANCING FEATURES) AS WELL AS VIAQ INFORMATION IS REQUIRED ALONG WITH A MECHANICAL PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. 12. PIPING INSULATION SHALL MEET THE REQUIREMENTS OF 1415 OF THE WSEC: TABLE 14-8 MINIMUM PIPE INSULATION (INCHES) FLUID DESIGN INSULATION CONDUCTMiY INAL PIPE DIAMETER IN.) OPERATING TEMP. GONDUCTMiY RANGE MEAN RATING RUNOUTS' 1 AND p1 TO 2 2 TO > 4 TO 8 > 8 RANGE 'F Btu- in/h -FT2- F I TEMP. 'F UP TO 2 J LESS 1 1 J HEATING SYSTBAS (STEM, CONDENSATE AND HOT WATER) NOMINAL INSULATION THICKNESS ABOVE 350 0.32 -0.34 250 1.5 2.5 2.5 3.0 3.5 3.5 251 -350 0.29 -0.31 200 1.5 2.0 2.5 2.5 3.5 3.5 201 -250 0.27 -0.30 150 1.0 1.5 1.5 2.0 2.0 3.5 141 -200 0.25 -0.29 125 0.5 1.5 1.5 1.5 1.5 1.5 105-140 0.24-0.28 0.24 -0.28 100 1.5 1.0 1.0 1.0 1.5 1.5 ESTIC WATER 105 MATER 10.24-0.28 I 100 1 0.5 1 1.0 I 1.0 I 1.5 1 1.5 1 1.5 COOLING SYSTEMS (CH X55 0.23-021 75 0.5 0.5 0.75 1.0 1.0 BELOW 40 0.23 -0.27 75 1.0 I 1.0 I 1.5 I 1.5 I 1.5 11.0 1.5 CONTRACTOR'S LICENSE NUMBER: INNER 1591* AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141 SEATTLE: (253) 839 -2126 FAX: (283) 135 -3432 P.O. Box 614 - AUBURN, WASHINGTON 98071 @ UNIVERSAL REFRIGERATION DRAWING -200t PRINT /PLOT DATE: 159 11/2/10 PROJECT START DATE: 11/2/10 DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: 10218 SHEET NUMBER: SCOPE OF WORK JOB #1218 I. INSTALL (2) EXHAUST FANS. 2. INSTALL (2) GAS-FIRED UNIT HEATERS. 3. INSTALL VENT DUCTWORK. 4. INSTALL NATURAL GAS PIPING. 159 11/2/10 PROJECT START DATE: 11/2/10 DRAFTER: DESIGNER: PROJECT MANAGER: JOB NUMBER: 10218 SHEET NUMBER: PENDING CITY APPROVAL) PLA ED EQUID STANT E.S.F. SPRINKL _ -1 EARS 1 4 CAP u ■ ■ 1"4) AT. c AS II STANT R NEARS IS-VENT 4'-!4).- NAT —GAS NAT.IC AS NMI NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. ■ I-IVAC FLAN AND NAT. CHAS PIPING FLAN SCALE: 3/32" = 1 -0" REVIEWED FOR CODE COMPLIANCE L P1DMVED Na 6 0 2010 City of Tukwila BUILDING nivisim 1 -1/2 ". N T. GAS 6 5 LBS. PRES URE '2[11Z-Ea400a -AIR CCNDItIONING - NEAT FJIF$ - Rl RIGERATION- CONTRACTOR'S LICENSE NUMBER: UNIVERI 1591* AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141 SEATTLE: (253) 839 -2126 FAX: (253) 133 -3432 P.O. 50X 614 - AUBURN, WASHINGTON 98011 @ UNIVERSAL REFRIGERATION DRAWING -2001 z 0 0 0 (1) w 0 z _0 w cc w (A 1- CC w 0 w Q 0 0 CO w cc 0 a a w cr) O w w CC U Lj W Z 0 CC UD W a w w m cry RECEIVED NOV 15 2010 C/7 I'P ICRf Tf'DATE: co 00 TM 00 0) z 0 CD z U w CC Q Q CC w N 11/2/10 PROJECT START DATE: 11/2/10 DRAFTER: CFN DESIGNER:. JLA PROJECT MANAGER: BG JOB NUMBER: 10218 SHEET NUMBER: M -1 FREEZE PROTECTION CALCULATION EQUIPMENT OUTPUT TOTAL STUN _ = /SQ. FT. - WAREHOUSE SQUARE FOOTAGE (2) UNIT HEATERS x (166,000) STUN OUTPUT 42,198 SQ. FT. = 13TUN /SQ. FT. 332,000 �TUI -I _ - 41,298 SQ. FT. = 1.�5 STUN /SQ. FT. '2[11Z-Ea400a -AIR CCNDItIONING - NEAT FJIF$ - Rl RIGERATION- CONTRACTOR'S LICENSE NUMBER: UNIVERI 1591* AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141 SEATTLE: (253) 839 -2126 FAX: (253) 133 -3432 P.O. 50X 614 - AUBURN, WASHINGTON 98011 @ UNIVERSAL REFRIGERATION DRAWING -2001 z 0 0 0 (1) w 0 z _0 w cc w (A 1- CC w 0 w Q 0 0 CO w cc 0 a a w cr) O w w CC U Lj W Z 0 CC UD W a w w m cry RECEIVED NOV 15 2010 C/7 I'P ICRf Tf'DATE: co 00 TM 00 0) z 0 CD z U w CC Q Q CC w N 11/2/10 PROJECT START DATE: 11/2/10 DRAFTER: CFN DESIGNER:. JLA PROJECT MANAGER: BG JOB NUMBER: 10218 SHEET NUMBER: M -1