HomeMy WebLinkAboutPermit M10-159 - SHASTA BEVERAGESSHASTA BEVERAGE
1227 ANDOVER PK E
M10 -159
City ofkukwila
a
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: //www.ci.tukwila.wa.us
MECHANICAL PERMIT
Parcel No.: 3523049072
Address: 1227 ANDOVER PK E TUKW
Project Name: SHASTA BEVERAGES
Permit Number: M10-159
Issue Date: 12/02/2010
Permit Expires On: 05/31/2011
Owner:
Name: NATIONAL BEVERAGE CORP
Address: 8100 SW 10TH ST STE 4000 , PLANTATION FL 33324
Contact Person:
Name: BRYAN GALVIN
Address: PO BOX 614 , AUBURN WA 98071
Email: BRYAN @UNIVERSALREFRIG.COM
Contractor:
Name: UNIVERSAL REFRIGERATION INC
Address: PO BOX 614 , AUBURN WA 98071 -0614
Contractor License No: UNIVERI159RF
Phone: 253 - 939 -5501
Phone: 253 939 -5501
Expiration Date: 04/01/2012
DESCRIPTION OF WORK:
INSTALL (2) ROOF FANS AND (2) UNIT HEATERS.
Value of Mechanical: $7,400.00
Type of Fire Protection: UNKNOWN
Permit Center Authorized Signature:
Fees Collected: $281.56
International Mechanical Code Edition: 2009
Date: 12 [Ml p
I hereby certify that I have read and (exanlined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not pre -uhte to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signatur
Print Name:
c° l�Je\t/1
Date: t/ Z (t')
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC-4/10
M10 -159 Printed: 12 -02 -2010
• •
PERMIT CONDITIONS
Permit No. M10 -159
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: AU mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
10: ** *FIRE DEPARTMENT CONDITIONS * **
11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
12: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2007
edition).
13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder
systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer
licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050).
14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: IMC -4/10
M10 -159 Printed: 12 -02 -2010
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
Mechanical Permit No. 144 10- s
Project No.
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: ,F2-,.. 04/ — 90 72_
Site Address: /7-7.- 7 4ae• vey• nCwi s itS71 Suite Number:
Tenant Name: ,... aciert P�t/t4,2, 4, •
Property Owners Name: i1474c ".4 / SWe-rw ,e. C.70 .
Mailing Address: / 2. -1 �btelo 4.r- _g/
New Tenant:
Floor:
❑ Yes
❑ ..No
//, ew;/4
City
t444 •
State
9'8698
Zip
CONTA T PERSON - Who do we
hr 4=4-*/ r �G.^7 'CH 4iMRN,1Day Telephone: 2 9 3q Name:
Mailing Address: PO 6.
E -Mail Address:
tl
wAl g5071-
City State Zip
Fax Number: Z5, —735— —
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
GI/ �Gi w-V�► WA- - y'$ °°/
City State Zip
Day Telephone: 2-53 93 9 5-5-6
/
Fax Number:
Expiration Date:
Contractor Registration Number:
a e r
4' /V/t P( /
Company Name:
Mailing Address:
City
• Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
State
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
H:4kpplicafions\Porms- Applications On Line\2009 Applications \ 1-2009 - Mechanical Permit Application.doe
Revised: 1 -2009
State
Zip
Page 1 of 2
Valuation of Project (contractor's bid price): $ 74/00 \ pe 5 tea'/ /4;caide --- 745p al" 1- v).
Scope of Work (please provide detailed information): At - /( rzlr) vao f ft4.1 5/ (-) (444 �] „C'( #3..,
r' /9//ae, CA44t4^4 () ittA /d-t..J Vo /Its L✓igrt
Use: Residential: New
Commercial: New
Fuel Type: Electric ❑
Lam'
Replacement
Replacement
Gas Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Types
Qty
Unit Type:
Qty
Unit TYPe:
Qty
Boiler' /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
,
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Fumace
Ventilation Fan Connected
to Single Duct
Z
Thermostat
Z-
15 -30 HP /1,000,000
BTU
Suspended/Wall/Floor
Mounted Heater
2
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000
BTU
Appliance Vent
Hood and Duct
Emergency Generator
50+ HP /1,750,000 BTU
Repair or addition to
Heat/Refrig/Cooling System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit <10,000
CFM
Incinerator - Comm/Ind
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING
ER • • WiA� %�;
Signa . e:
Print N
Mailing Address:
Day Telephone:
a. Fay es,y
Date: 1/—
(z$- 3>',, -ccO(
Gr/ . Y8D7/ -D4 y
State Zip
Date Application Accepted: �` i
III
Date Application Expires: ` (� _
Staff Initials: V____ I
H: WpplicationsWonns- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application:doe
Revised: 1 -2009
bh
Page 2 of 2
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: htq)://www.ci.tulcwila.wa.us
RECEIPT
Parcel No.: 3523049072 Permit Number: M10 -159
Address: 1227 ANDOVER PK E TUKW Status: PENDING
Suite No: Applied Date: 11/15/2010
Applicant: SHASTA BEVERAGES Issue Date:
Receipt No.: R10 -02306
Payment Amount: $281.56
Initials: WER Payment Date: 11/15/2010 11:32 AM
User ID: 1655 Balance: $0.00
Payee: UNIVERSAL REFRIGERATION
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 42303 281.56
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 225.25
000.345.830 56.31
Total: $281.56
doc: Receiot -06 Printed: 11 -15 -2010
k
F.
'
2--
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -670
Permit Inspection Request Line (206) 431 -2451
ymt0 -1y1
Project:
blPAS 1.4
Type of Inspection:
w1NAL
Address:
(2..2 7 Psr n1 0 osJ a.
h IL €._
Date Called:
-
Special Instructions:
Date Wanted:
12-
269
-10
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
4,.) &_ I • /'L —z, —t0
SPECTION FEE R ' U RED. Prio /o next,inspection. fee must be
at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection.
ipzr• .r �. •_ -
- r_ fir. rtc -a.- ."v recTs. yr tit
P•
z-
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT
(IA - tcs9
CITY OF TUKWILA BUILDING DIVISION P-
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
S 44 AS-rA P1F LIP itA40 C
Type of Inspection:
n N401 1--
Address:
1221 165-4 tfOtfia ct. _c)14 E__
Date Called:
•
Special Instructions:
- • .-
. . .
Date Wanted:
M-2C)-10
Cr......rm
p.m.
Requester:
Phone No:
D4942--.S10 -- 11-1/
3
ElApproved per applicable codes.
ca.! orrectionsrequired prior to approval.
COMMENTS:
0 lir tz.A.Pdtbci
kh-If4
• %qt%
ECTION FEE EQUIED.Priorto n tinspection. fee must be
6300 Southcenter. Blvd.. Suite 100. Call tO schedule reinSpection.
••■ •.• ekt ece,kt • - 6 yitie:WW 4N, .• • .:rgegefaiii./...= rtICLIMODFOSS.
1•
INSPECTION RECORD... a`p
Retain a copy with permit
INS ION ION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 02
6300 Southcenter Blvd., #100,, Tukwila. WA 98188 • (206) 431 -3670
Permit-Inspection Request Lune (206) 431 -2451 . •
Project:
-S 4 ASIT"A-
Type of Inspection:
171 N A
-
Address:
1 2-11 .t Jj R_ S' l ' _
Date Called:
Special Instructions:
.
Date Wanted:
t- Y 2>
t
a.m.
Requester:
Phon//e��No:
•45
❑ Approved per applicable codes.
LJCorrections required prior to approval.
COMMENTS: P•
61441.A. P\trt*t0. f *ye&4
•
e or: Date:
INSPECTION FEE R QUIRED. Pric r to next inspection..fee must be
p
id at 6300 Southcent r Blvd:, Suite 100. Call to schedule reinspection.
1
M:,'¢`.1: YTS. • b , - — . . • sa • • 1. • - yeast= _tiP•- ° 4�' .d ►rt.L- M .rte �
}
EQUIP You wiH receive an invoice from
Cali to sc tedule a re%ape on.
Word/Inspection Record Form.
3/06 T.F.D. Form F.P. 113
Needs Shift Inspection:
Sims;
Fire farm:
Mo
Pre- Fite
P'ertxtits:
pcupency Type:
EQUIP You wiH receive an invoice from
Cali to sc tedule a re%ape on.
Word/Inspection Record Form.
3/06 T.F.D. Form F.P. 113
REZNOR
PILE COPY
NEW!!
• �
0S
CODE FOR
R ODE COMPLIANCE
NOV 02010
VOET1
Power Vented
Model
UDAP
I 157
City of Tukwila
BUILDING DIVISION
RECEIVED
Low Static NOV 15 2010
PERMIT CENTER
Axial Fan Unit Heaters
for Residential and
Commercial /Industrial Use
CAS UNIT I-4E,4TER
4NG(NG DETAIL
WEATHER CAP
ROUND DUCT TYPE
DOUBLE WALL GAS
EAL AROUND
SEAL
WITH WEATHER
STORM COLLAR AND
BUILDING ROOF
—_ PROVIDE
BETWEEN
IN
SLEEVE
ROOF
lir
AND I" AIR
FLUE AND ROOF
(2) THREADED
FOR PROPER
3/8 "7 MINIMUM.
SPANNED
SEISMIC
TO
RODS SIZED
SUPPORt-
THRU UNISTRUT
BETWEEN TRUSSES
BRACING
BUILDING STRUCTURE.
FIXED DOWNTURN
ADJUSTABLE
LOUVERS.
FROM EACH CORNER
LOUVE --i4-,
VERTIG
-,�'
II 3
-BIRD PROOF
B (METALBESTOS)
VENT TNRU ROOF
STORM COLLAR
GAP
PENETRATION.
BUILDING
I'
I
TIGHT SEALANT
CONE FLASHING
�—
416N \
X .■12 Al& .W:/.
TRUSS
t
1 /
24 GAUGE MINIMUM �/
GALVANIZED FLUE PIPE.
UNIT
$
>:0.
HEATER"'
Npr
.W2
AIR FLOW
>WITM
__
COORDINATE MOUNTING HEIGHT
OWNER AND MANUFACTURERS
INSTALLATION INSTRUCTIONS.
EA
WITHu dia
q"
REZNOR
//-7/-( Z_
Model UDAP
Power Vented, Low Static Axial Fan Unit Heaters
for Residential and Commercial /Industrial Use
CGA 2.6b
ANSI Z83.8b
CSA International
Requirement
10.96 U.S.
- Sizes 30 -125
DESCRIPTION
Reznor® V 3 Series Model UDAP gas -fired unit heaters
are available in 14 sizes ranging from 30,000 to 400,000
BTUH gas input. Sizes 30 -125 are approved for residential
application. All sizes are approved for commercial /industrial
installations. Model UDAP heaters are designed for 82 -83%
thermal efficiency and are approved for installation in the
United States and Canada by the Canadian Standards As-
sociation (CSA).
Reznor® V 3 Series unit heaters have a refreshing new
appearance with a glossy white cabinet finish and less vis-
ible hardware. Each size cabinet is easily suspended from
either 2 or 4 suspension points. Or, an optional hanger kit for
Sizes 30 -125 allows for ceiling mounting. The low voltage
terminal strip on the outside of the cabinet makes connect-
ing control wiring easy with no panels to remove. The addi-
tion of a "G" terminal to the strip, along with the new design
of the circuit board, allows for fan only operation (without
adding relays). All units have a factory installed gas line nipple
to the exterior of the cabinet for easy gas service connec-
tion.
The preeminent new internal feature is the T -coRE2 ®
heat exchanger and single burner combustion system. Other
standard features include a single -stage gas valve, multi -try
direct spark ignition with 100% lockout, pressure switch to
verify vent flow, resiliently isolated venter motor, venter wheel
with improved housing, resiliently isolated axial fan and mo-
tor assembly, and a high temperature limit control. Sizes 30-
125 also include a flame rollout safety switch. Operation is
controlled through an integrated circuit board. The circuit
board monitors heater operation and has LED diagnostic in-
dicator lights to identify abnormalities in control functions.
The new V3 Series unit heaters are designed to pro-
vide all the features you expect in a Reznor heater plus im-
proved efficiency, easier installation, and a new look - both
inside and out.
Form RZ -NA C- UDAP /S, Page 10
STANDARD FEATURES
• Sizes 30 -125 certified for residential heating
application
• Sizes 30-400 certified for commercial /industrial
heating application
• 82 -83% Thermal efficient -- TOP in its class!
• 50 -60 °F Rise range
• NEW T -coRE2 ® design titanium stabilized aluminized
steel heat exchanger (patent pending)
• NEWT coRE2® design single burner combustion
system including a one -piece burner assembly
(patent pending)
• 115/1/60 Supply voltage
• 115 Volt open fan motor with internal overload
protection
• Transformer for 24 -volt controls
• Integrated circuit board with diagnostic indicator
lights
• Fan relay (included on the circuit board)
• Multi -try direct spark ignition with 100% lockout
• Natural or propane single -stage gas valve (field
adjustable for operation to 9,000 ft elevation)
• Vibration /noise isolated fan and venter motors -
designed for low noise operation
• 2 -pt and 4 -pt Suspension - standard on all sizes
• External terminal strip for 24 -volt wiring
• External gas connection
• Full fan guard - engineered for safety
• Improved cabinet design with less visible hardware
and a NEW Reznor appearance
OPTIONAL FEATURES - FACTORY INSTALLED
• Two -stage natural or propane gas valve
• 409 or 316 Stainless steel heat exchangers
• 208 or 230 Single phase voltage
• Totally enclosed fan motor (115V only)
• Common venting with other gravity vented
Category I appliance(s)
ACCESSORIES - FIELD INSTALLED
• Vent cap
• Thermostat
• Thermostat guard with locking cover
• Vertical louvers - new design
• Downtum nozzle kits - new design
• Gas conversion kits (natural and propane)
• Master /Slave controls for zoning up to six units
• Ceiling suspension kit - Sizes 30 -125
• Hanger kits for 1" pipe
• Stepdown transformer (for 230/3 and 460/3 supply
voltage)
• Manual shutoff valves
v
Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS
P and O-
Hanger
Dimensions
for 4 -pt
Suspension
M and N - Hanger Dimensions
for both 2 -pt and 4 -pt Suspension
N -► M
1
P
1
1
TOP VIEW
R - Hanger
Dimension for
2 -pt Suspension
3/8 " -16 Female Thread
- all suspension points
1
Form RZ -NA C- UDAPIS, Page 12
Thermostat
Connection
(30 -125 Vertical;
150 -400 Horizontal)
Combustion
Air Inlet
REAR
VIEW
\,‘
Y
Line Voltage
Inlet (connects
at circuit board)
I(
H —►
External
Gas
Connection
F
E
r
Vent Connection
(see Technical
Data for size)
RIGHT SIDE
VIEW
(Access Panel)
u
MODEL UDAP TECHNICAL DATA- Sizes 30 -125
Size
150
30
45
60
75
100
125
Input Heating Capacity
BTUH
30,000
45,000
60,000
75,000
105,000
120,000
kw/h
8.8
13.2
17.6
22.0
30.8
352
Thermal Efficiency( %)
82
83
83
83
83
83
Output Heating Capacity"
BTUH
24,600
37,350
49,800
62,250
87,150
99,600
kw/h
7.2
11.0
14.6
18.3
25.6
292
Gas Connection (inches) 8
Natural
1/2
1/2
1/2
1/2
1/2
1/2
Propane
1/2
1/2
1/2
1/2
1/2
1/2
Vent Connection Size c (inches diameter)
4
4
4
4
4
4
Control Amps (24 volt)
1.0
1.0
1.0
1.0
1.0
1.0
Full Load.Amps (115 volt)
1.9
2.4
2.4
3.3
3.9
5.1
Mwdmum Over Current Protection (115V) °
15
15
15
15
15
15
Normal Power Consumption (watts)
109
155
155
217
276
354
Discharge Air Temperature Rise ( °F)
50
55
60
60
60
60
Air Volume
CFM
456
629
769
961
1345
1537
M3 /minute
12.9
17.8
21.8
27.5
36.7
45.9
Discharge Air Opening Area
ft2
0.96
0.96
1.25
1.25
2.01
2.01
M2
0.09
0.09
0.12
0.12
0.19
0.19
Output Velocity
FPM
475
656
616
770
668
763
M/minute
145
200
188
238
196
245
Fan Motor HP a
Open
0.02
0.03
0.03
0.06
1/30
1/20
Enclosed
N.A
N.A.
N.A.
N.A
1/4
1/4
Fan Motor RPM
1550
1550
1550
1550
1050
1050
Fan Diameter (inches)
10
10
12
12
16
16
ApproAmate Net Weight
Ibs
54
59
67
72
96
101
kg
24
27
30
33
44
46
Appro)dmate Ship Weight
Ibs
61
66
74
79
118
123
kg
27
30
33
36
54
56
MODEL UDAP TECHNICAL DATA Sizes 150 - 400
Size
150
175
200
225
250
300
350
400
Input Heating Capacity
BTUH
150,000
175,000
200,000
225,000
250,000
300,000
350,000
400,000
kw/h
43.9
51.2
58.6
65.9
73.2
87.8
102.5
117.1
Thermal Efficiency( %)
83
83
83
83
83
83
83
83
Output Heating CapacityA
BTUH
124,500
145,250
166,000
186,750
207,500
249,000
290,500
332,000
kw/h
36.4
42.5
48.6
54.7
60.8
72.9
85.1
97.2
Gas Connection (inches) B
Natural
1/2
1/2
1/2
3/4
3/4
3/4
3/4
3/4
Propane
1/2
1/2
1/2
3/4
3/4
3/4
3/4
3/4
Vent Connection Size C (inches diameter)
5
5
5
5
5
6
6
6
Control Amps (24 volt)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Full Load Mips (115 volt)
3.8
3.8
4.6
7.5
7.5
11.0
11.0
11.0
Maximum Over Current Protection (115V) 0
15
15
15
15
15
20
20
20
Normal Power Consumption (watts)
392
392
491
747
747
1086
1086
1086
Discharge Air Temperature Rise ( °F)
60
60
60
60
60
60
60
60
Air Volume
CFM
1921
2242
2562
2882
3202
3843
4483
5123
M3 /minute
54.4
63.5
72.5
81.6
90.7
108.8
126.9
145.1
Discharge Air Opening Area
ft2
2.56
2.56
2.56
3.51
3.51
4.79
4.79
4.79
M2
0.24
0.24
0.24
0.33
0.33
0.45
0.45
0.45
Output Velocity
FPM
752
877
1003
820
911
802
936
1069
M/minute
229
267
306
250
278
244
285
326
Fan Motor HP E
Open
1/6
1/6
1/6
1/4
1/4
1/2
1/2
1/2
Enclosed
1/4
1/4
1/4
1/4
1/4
1/2
1/2
1/2
Fan Motor RPM
1050
1050
1050
1050
1050
1050
1050
1050
Fan Diameter (inches)
18
18
18
20
20
24
24
24
Approximate Net Weight
lbs
172
187
187
203
215
269
294
306
kg
78
85
85
92
98
122
133
139
Approbmate Ship Weight
lbs
204
219
219
245
257
321
346
358
kg
93
100
100
111
117
146
157
163
A CSA ratings for altitudes to 2000 ft. B Size shown is for gas connection to a single -stage gas valve, not supply line size.
C Smaller and /or larger vent pipe diameters may be permissible; refer to the Venting Installation Manual for Power Vented Units.
D MOPD = 2.25 x (largest motor FLA) + smallest motor FLA Answer is rounded to the nearest commercially available circuit breaker.
e All other information is this table is based on a heater equipped with a standard 115 volt open fan motor.
Form RZ -NA C- UDAP /S, Page 11
MODEL UDAP DIMENSIONS (inches *1/16
Size
A
B
C
D
E
F
G
H
J
K
M
N
P
Q
R
30,45
12 -1/8
26 -5/8
10
13 -13/16
26
21 -9/16
5 -3/16
6 -1/2
2 -11/16
3 -7/8
17 -3/8
11/16
4 -5/16
13
9 -9/16
60
15 -1/8
26 -5/8
13
13 -13/16
27
21 -9/16
7-7/8
6 -1/2
5 -1/2
3 -7/8
17 -3/8
11/16
4 -5/16
13
10 -1/2
75
15 -1/8
26 -5/8
13
13 -13/16
27 -5/8
21 -9/16
7 -7/8
6 -1/2
5-1/2
3 -7/8
17 -3/8
11/16
4 -5/16
13
10 -1/2
100
23 -1/8
26 -5/8
21
13 -13/16
28 -5/8
21 -9/16
14 -1/2
6-1/2
8 -3/4
3 -7/8
17 -3/8
11/16
4 -5/16
13
10 -1/2
125
23 -1/8
26 -5/8
21
13 -13/16
29 -3/8
21 -9/16
14 -1/2
6 -1/2
8 -3/4
3 -7/8
17 -3/8
11/16
4 -5/16
13
10 -1/2
150,
175,
20-1/8
38 -3/16
16
23
42
35 -3/8
8 -1/2
8 -1/4
5 -7/16
6 -1/2
25 -11/16
1 -3/8
8 -3/16
22 -3/16
16 -3/8
200
225'
250
26 -1/8
38 -3/16
22
23
42
35 -3/8
13 -1/16
8 -13/16
9
6 -1/2
25 -11/16
1 -3/8
8 -3/16
22 -3/16
15 -5/8
300,
350,
34 -1/8
41
30
23
42
35 -3/8
17 -1/16
9
11 -13/16
7 -5/16
27 -11/16
1 -3/8
8 -3/16
22 -3/16
16 -3/16
400
MODEL UDAP DIMENSIONS (mm±2
Size
A
B
C
D
E
F
G
H
J
K
M
N
P
O
inches
30,45
308
676
254
351
660
548
132
165
68
98
441
17
110
0
243
60
384
676
330
351
686
548
200
165
140
98
441
17
110
330
267
75
384
676
330
351
702
548
200
165
140
98
—
17
110
330
267
100
587
676
533
351
727
548
368
165
222
441
17
110
330
267
125
587
676
533
351
746
548
368
165
222
98
441
17
110
330
267
150,
175,
511
970
406
584
1067
899
216
210
138
165
652
35
208
564
416
200
225'
250
664
970
559
584
1067
899
332
224
229
165
652
35
208
564
397
300,
350,
867
1041
62
584
1067
899
433
229
300
186
703
35
208
564
411
400
CLEARANCES
Size
Top
Flue Connector
Access Panel
Non - Access Side
Bottom*
Rear
inches
rrrn
inches
rrm
inches
rrm
inches
rrrn
inches
rrrn
inches
rrrn
30 -125
1
25
6
152
18
457
1
25
1
25
18
457
150 -400
4
102
6
152
18
457
2
51
1
25
18
457
*Suspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor.
Form RZ -NA C- UDAP /S, Page 13
SAMPLE SPECIFICATIONS
GAS - FIRED, POWER VENTED UNIT HEATERS
Provide (82 %, 83 %) high - efficiency, power vented, gas -fired unit heaters manufactured as Reznor® brand units designed for use in
building areas where higher reliability is required and venting is either vertical or horizontal.
Model UDAP
Each of the 14 sizes in the Model UDAP series shall be equipped for use with (natural) (propane) gas. Gas connection shall be
external to the cabinet.
Heat Exchanger
The heater shall be equipped with a multicell, 4 pass serpen-
tine style steel heat exchanger. Heat exchanger tubes shall be
press fabricated of (titanium stabilized, corrosion resistant
aluminized steel) (409 stainless steel) (316 stainless steel). All
heat exchangers shall be fabricated with no welding or
brazing, only tool pressed mechanical joints. All heat ex-
changer cells shall be designed with an aerodynamic cross
section to provide maximum airflow.
Burner
The units shall incorporate a single, one piece bumer assem-
bly with a single orifice. The bumer shall have a continuous
wound close pressed stainless steel ribbon separating the
flame from the bumer interior. All units shall have a single
venturi tube and orifice supplying fuel to a one -piece bumer
housing. Each heat exchanger cell shall use balanced draft
induction to maintain optimum flame control.
Controls
Controls shall include a (single- stage) (two - stage) gas valve;
direct spark multi -try ignition with electronic flame supervision
with 100% lockout integrally controlled via a printed circuit
control board. The control board shall also incorporate
diagnostic lights, DIP switches for fan overrun settings, and a
relay for fan only operation. All units shall be equipped with a
safety limit switch.
All controls shall be enclosed in the unit housing to protect
them from accidental damage that could be caused by factors
in the building that would adversely affect external controls.
Combustion Air and Venting
The unit shall have a factory- installed power venter device to
draw combustion air through an inlet in the rear of the cabinet.
The combustion air /venting system shall include a vibration
isolated power venter motor and wheel assembly and a
combustion air pressure switch. Unit Sizes 30 -125 shall
include a flame rollout switch. (The unit shall be equipped with
an approved common vent option to allow venting with
another gravity vented Category I gas appliance).
(A vent cap shall be available.)
Electrical
Operation shall be controlled by an integrated circuit board
that includes LED diagnostic indicator lights. Supply voltage
connections are made at the circuit board. 24 -volt control
connections shall be made on an externally mounted terminal
strip with connections (W1, W2, R, and G). All internal wiring,
both line and control voltages, shall be terminated by insu-
lated terminal connectors to minimize shock hazard during
service.
Form RZ -NA C- UDAP /S, Page 14
Each unit shall be equipped for use with (115/1) (208/1) (230/
1) volt power supply. (Stepdown transformers shall be
available to be field installed for use with (230/3) (460/3) volt
power supply.)
Cabinet
The cabinet shall be low profile with a pre -coat or powdercoat
RAL 1001 white paint finish. Finish shall be a minimum 80
gloss on G30 galvanized steel. The cabinet shall be con-
structed so that screws are not visible from the bottom, front,
or sides, except for service panel and accessories. Unit
construction shall incorporate a beveled front comer on
control side for additional cabinet rigidity. All units shall be
manufactured with a tooled drawn supply air orifice on the rear
panel to reduce fan inlet noise.
The unit shall be designed for ceiling suspension featuring
3/8 " -16 female threads (hanger kits for 1" pipe) at both 2 -point
and 4 -point locations with no additional adapter kits. (Hanger
kit for ceiling mounting shall be available for Sizes 30 -125.)
The cabinet shall be equipped with RAL 3005 burgundy
painted, roll - formed horizontal louvers. Louvers shall be spring
held and adjustable for directing airflow. (Vertical louvers)
(downturn nozzles) (downturn nozzles with vertical louvers)
shall be available.
The cabinet shall be equipped with a full safety fan guard with
no more than'/ inch grill spacing on Sizes 30-125 or no more
than 1 inch on Sizes 150 -400. The (open dripproof) (enclosed)
motor and fan assembly shall be resiliently mounted to the
cabinet to reduce vibration and noise.
The unit shall be designed with a full opening service access
panel complete with screw closure attachment and lifting
handle for removal. All components in the gas train, all
standard electrical controls, and the power venter shall be
within the service compartment.
Minimum top clearance from combustibles shall be 1" for
Sizes 30-125 and 4" for Sizes 150 -400. Minimum bottom
clearance from combustibles shall be 1" for all sizes. Minimum
clearance from combustibles on non - service side shall be 1"
for Sizes 30 -125 and 2" for Sizes 150 -400.
Certifications
Model sizes 30, 45, 60, 75, 100 and 125 MBH shall be
certified to CSA International Requirement 10 -96 U.S. for
RESIDENTIAL INSTALLATION. All sizes shall be design
certified by the Canadian Standards Association to ANSI
Z83.8b and CGA 2.6b for commercial /industrial installation.
Units shall be manufactured in an ISO 9002 certified facility.
Manufacturer must have a minimum of 50 years experience in
the manufacture of gas fired unit heaters.
Type CRBA
Belt Drive Centrifugal
Power Roof Ventilators
INDUSTRIES DIVISION
AMERICAN COOLAIR CORPORATION
P.O. Box 2300 Jacksonville, Florida 32203
Phone: (904) 389-3646
Fax: (904) 387-3449 • (904) 381 -7560
E -mail: fans @coolair.com
Internet: www.coolair.com
Standard Fan Features
• Non -overloading aluminum wheel
computer balanced.
• Force ventilated motor compartment
isolated from airstream.
• Variable pitch motor pulley.
• Vibration isolators on drive frame.
• Weatherproof spun aluminum housin
• NEMA Standard open drip -proof mot
• Overlapping wheeUnlet venturi.
• Heavy duty self- aligning pillow -block
bearings with cast iron housing.
• AMCA label for air and sound.
• Polypropylene birdscreen.
D
H O.D.
1 61r 16 /r J I.D. 1 1
8' STD.
HEIGHT
1'
Sheet ( of /
11/r THICK
INSULATION
r--- ESQ.
Optional Features
• UL Label for Standard 705.
• Disconnect switch (loose or
factory mounted and wired).
Backdraft damper.
Roof curb (damper shelf
optional).
• Epoxy coating.
> •
•
9.
ors.
FSQ. I
�� G SQ.
A SQ. I.D.
2'
SIZE
Ventilator Dimensions
Roof Curb and Damper Dimensions
A
B
C
D
E
F
G
H
J
06-10
18
231/8
201/2
241/2
121/2
10
111/4
161/2
131/4
12 -15
23
28 5/8
22 1/2
29 1/2
17 1/2
15
16 1/4
21 1/2
18 1/4
16-20
30
35 1/2
24 5/8
36 1/2
24 1/2
22
23 1/4
28 1/2
25 1/4
24
34
42 3/4
32 1/2
40 1/2
28 1/2
26
27 1/4
32 1/2
29 1/4
30
40
50 1/4
36 3/4
46 1/2
34 1/2
32
33 1/4
38 1/2
35 1/4
36
46
61 3/4
44 1/4
52 1/2
40 1/2
38
39 1/4
44 1/2
41 1/4
44
56
71 1/4
49
62 1/2
50 1/2
48
49 1/4
54 1/2
51 1/4
52
65
83 3/4
55 1/2
71 1/2
59 1/2
57
_ 58 1/4
63 1/2
60 1/4
Specifications
❑ Check here for UL 705.
FAN DATA
MOTOR DATA
Dimensions In Inches
FAN NO.
QTY.
MODEL NO.
CFM
SP
RPM
SONES
HP
RPM
VOLTAGE
PH
HZ
ENCLOSURE
ACCESSORIES AND REMARKS
.6a-•2
Z
CR51 / Z
/'f(O
/g I
/O.2.
/os
//5—
(Go
cvti^6 9'- Spp
PROJECT
LOCATION
ENGINEER Xr
CONTRACTOR . Iv.
SUBMITTED BY \ //A—
APPROVED BY 7,c7•
DATE //- 2 ^l0
DATE / e. lf7
EFFECTIVE MAY 1, 2003
SHIPPING WEIGHTS AND DIMENSIONS
ILG INDUSTRIES
FORM 705 -23 -3 (5 -03)
PAGE 10 OF 20
CRBA
MODEL HP BOX / UPS / SIZE WGT. CUBIC
CRATE TRUCK (INCHES) (LBS) FEET
CRBA06G 1/4 BOX TRUCK 26X26X27
CRBA08G 1/4 BOX TRUCK 26X26X27
CRBAIOG 1/4 BOX TRUCK 26X26X27
CRBAI2G 1/4 BOX TRUCK 34X34X32
CRBAI2H 1/3 BOX TRUCK 34X34X32
CRBAI2J 1/2 BOX TRUCK 34X34X32
CRBAI2K 3/4 BOX TRUCK 34X34X32
CRBAI3G 1/4 BOX TRUCK 34X34X32
CRBAI3H 1/3 BOX TRUCK 34X34X32
CRBAI3J 1/2 BOX TRUCK 34X34X32
CRBAI3K 3/4 BOX TRUCK 34X34X32
CRBAISG 1/4 BOX TRUCK 34X34X32
CRBAI5H 1/3 BOX TRUCK 34X34X32
CRBAI5J 1/2 BOX TRUCK 34X34X32
CRBA15K 3/4 BOX TRUCK 34X34X32
CRBAI5L 1.0 BOX TRUCK 34X34X32
CRBAI6G 1/4 CRATE TRUCK 42X42X34
CRBAI6H 1/3 CRATE TRUCK 42X42X34
CRBAI6J 1/2 CRATE TRUCK 42X42X34
CRBAI6K 3/4 CRATE TRUCK 42X42X34
CRBAI6L 1 CRATE TRUCK 42X42X34
CRBAI6M 11/2 CRATE TRUCK 42X42X34
CRBAI8H 1/3 CRATE TRUCK 42X42X34
CRBAI8J 1/2 CRATE TRUCK 42X42X34
CRBAI8K 3/4 CRATE TRUCK 42X42X34
CRBAI8L 1 CRATE TRUCK 42X42X34
CRBA18M 11/2 CRATE TRUCK 42X42X34
CRBAI8N 2 CRATE TRUCK 42X42X34
CRBA20J 1/2 CRATE TRUCK 42X42X34
CRBA20K 3/4 CRATE TRUCK 42X42X34
CRBA2OL 1 CRATE TRUCK 42X42X34
CRBA2OM 11/2 CRATE TRUCK 42X42X34
CRBA20N 2 CRATE TRUCK 42X42X34
88
90
91
95
98
103
95
98
102
107
92
95
98
102
106
186
188
192
194
197
202
161
165
169
174
183
188
194
196
201
206
213
11
11
11
22
22
22
22
22
22
22
22
22
22
22
22
22
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
•
1
PE 3�� As CPY
� ,� �..pl $ -� P i �<. }7.
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M10 -159
PROJECT NAME: SHASTA BEVERAGES
SITE ADDRESS: 1227 ANDOVER PK E
X Original Plan Submittal Response to Incomplete Letter #
DATE: 11 -15 -10
Response to Correction Letter #
Revision # After Permit Issued
DEPART ENTS: ,��
S C. 0 Wt c `` �
ullding ivislon �� ire Prevention Lim
Public Works ❑ Structural ❑
Planning Division
Permit Coordinator
Fri
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -16 -10
Complete
Comments:
Incomplete
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions Not Approved (attach comments)
DUE DATE: 12 -14 -10
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28-02
Contractors or Tradespeople liter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
UNIVERSAL REFRIGERATION INC
2539395501
Po Box 614
Auburn
WA
980710614
King
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
600599723
Active
UNIVERI159RF
Construction Contractor
12/6/1985
4/1/2012
Commercial/Industrial/ Refrig
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
RAEDER, STEVEN C
Cancel Date
01/01/1980
Amount
VERNON, GUY E
25
01/01/1980
01/01/1980
JACKSON, SHELDON G
04/01/2011
01/01/1980
01/01/1980
OSENBAUGH, CHARLES R
03/02/2010
01/01/1980
01/01/1980
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
AMERICAN STATES INS
CO
EX903622
12/06/2001
Until Cancelled
$6,000.00
03/18/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
25
AMERICAN
STATES INS CO
01CG7497626
04/01/2010
04/01/2011
$1,000,000.00
03/02/2010
24
AMERICAN
STATES INS CO
01CG7497625
04/01/2009
04/01/2010
$1,000,000.00
03/09/2009
23
AMERICAN
STATES INS CO
01CG7497624
04/01/2008
04/01/2009
$1,000,000.00
03/11/2008
22
FIRST NAT'LINS
CO OF AMERICA
01CG7497623
04/01/2007
04/01/2008
$1,000,000.00
03/01/2007
21
FIRST NATIONAL
INS. CO. OF AME
01CG7497622
04/01/2006
04/01/2007
$1,000,000.00
03/13/2006
20
FIRST NATIONAL
INSURANCE CO
OF
01CG749762
04/01/2006
04/01/2007
$1,000,000.00
03/10/2006
19
AMERICAN CAS
INS CO
C2026115262
04/01/2005
04/01/2006
$1,000,000.00
03/23/2005
18
AMERICAN CAS
CO OF READING
C2026115262
04/01/2004
04/01/2005
$1,000,000.00
04/12/2004
17
TRANSPORTATION
INS CO
C2026115262
04/01/2004
04/01/2005
$1,000,000.00
03/15/2004
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
12/02/2010
PENDING CITY APPROVAL,
SEPARATE PERMIT
REQUIRED FOR:
Ci Mechanical
lectricat
!Plumbing
Comas Piping
City of Tukwila
MILTING DIVISION
REVISIONS
No changes shall be made to the scope
• of work without prior approval of
Tukwiia Building Division.
NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71
` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , :
FAN
NV,4C 4EVIATIONS
1 STI UT
AFF ABOVE FINISHED FLOOR
BPP BACKDRAPt DAMPER
BTUH BRITISH THERMAL UNIT PER HOUR
CD CEILING DIFFUSER
CFM CUBIC FEET PER MINUTE
DB DECIBEL
DEG DEGREE
DI-1 DUCT NEATER
DN POUIN
EA EXHAUST AIR
EER ENERGY EFFICIENCY RATIO
EG EXHAUST GRILLE
ESP EXTERNAL STATIC PRESSURE
EW7 ENTERING WATER TEMPERATURE
EXH EXHAUST
FCU FAN COIL UNIT
FD FIRE PAMPER, FLOOR DRAIN
FOIC FURNISHED BY OWNER INST. SY CONTRACTOR
FPM FEET PER MINUTE
FSD FIRE AND SMOKE PAMPER
GA GAUGE
GF GAS FURNACE
GPM GALLONS PER MINUTE
GRID GRILLE, REGISTER, DIFFUSER
CsWB GYPSUM UJALL60ARP
HP HORSEPOWER, 1-1EA7 PUMP
HVAC HEATING, VENTILATING AND AIR CONDITIONING
1-1VAC AREVI4T1ONS
ID
SEPARATE PERMIT
REQUIRED FOR:
Ci Mechanical
lectricat
!Plumbing
Comas Piping
City of Tukwila
MILTING DIVISION
REVISIONS
No changes shall be made to the scope
• of work without prior approval of
Tukwiia Building Division.
NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71
` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , :
FAN
054 1D
1 STI UT
1-1VAC AREVI4T1ONS
ID
SECTION 302.3.53 WSIAQC - OUTDOOR AIR SHALL 5E DISTRIBUTED TO EACH
ROOM /AREA. WHERE SUPPLY IS SEPARATED FROM EXHAUST POINTS 5Y
DOORS, PROVISIONS SHALL 5E MADE TO ENSURE AIRFLOW 5Y UNDERCUTTING
DOORS, TRANSFER GRILLES, OR SIMILAR MEANS. DOORS SHALL 5E UNDERCUT
A MINIMUM 1/2" ABOVE FLOOR COVERING (SEE BELOW).
CFM THROUGH DOOR -.NO TRANSFER GRILLE
ID
IRH
KUJ
MBH
MCD
NC
NIC
NTS
05D
OC
OD
05A
PD .
RPM
RA
RAG
SA
SG
SP
SSG
TED
TG
TYP
VAV
VFD
VTR
VVT
INSIDE DIMENSION
INFRARED HEATER
KILOWATT
THOUSAND BTU PER HOUR
MOTORIZED CONTROL DAMPER
NOISE CRITERIA
NOT IN CONTRACT
NOT TO SCALE
OPPOSED SLADE DAMPER
ON CENTER
OUTSIDE DIMENSION OR DIAMETER
OUTSIDE AIR
PRESSURE DROP
REVOLUTIONS PER MINUTE
RETURN AIR
RETURN AIR GRILLE
SUPPLY AIR
SUPPLY GRILLE
STATIC PRESSURE
SIDEWALL SUPPLY GRILLE
TO 5E DETERMINED
TRANSFER GRILLE
TYPICAL
VARIABLE AIR VOLUME
VARIABLE FREQUENCY DRIVE
VENT TO ROOF
VARIABLE VOLUME AND TEMPERATURE
ACLU=
-� �
I
SEPARATE PERMIT
REQUIRED FOR:
Ci Mechanical
lectricat
!Plumbing
Comas Piping
City of Tukwila
MILTING DIVISION
REVISIONS
No changes shall be made to the scope
• of work without prior approval of
Tukwiia Building Division.
NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71
` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , :
FAN
054 1D
1 STI UT
1 ON /NON - ED UCTE r) RETURN
ID
SECTION 302.3.53 WSIAQC - OUTDOOR AIR SHALL 5E DISTRIBUTED TO EACH
ROOM /AREA. WHERE SUPPLY IS SEPARATED FROM EXHAUST POINTS 5Y
DOORS, PROVISIONS SHALL 5E MADE TO ENSURE AIRFLOW 5Y UNDERCUTTING
DOORS, TRANSFER GRILLES, OR SIMILAR MEANS. DOORS SHALL 5E UNDERCUT
A MINIMUM 1/2" ABOVE FLOOR COVERING (SEE BELOW).
CFM THROUGH DOOR -.NO TRANSFER GRILLE
FIG. 15 SECTION 25.19 1991 ASHRAE
b
CFM
ACLU=
-� �
I
a +b +c +d
L.
600
_ - A P = 30 inches
I 4
Assume a, b, c = .1 inches
c d = .5 inches
ACW = 2 inches
I Average door
1
EF -1,2
ILG
m
`-- ACLU .2 inches
,2 avg. crack width (ACLU) d
Now correlate to pressure differential of
NOT acceptable LP = .15 inches H2O
ROOMS SUPPLIED WITH l.55
15
CFM = CFM CFM +.683
X400 CFM OR MORE (.3 01 =
REQUIRE TRANSFER GRILLES (AP =.151)
= 600x.68 = 408CFM
CV
SEPARATE PERMIT
REQUIRED FOR:
Ci Mechanical
lectricat
!Plumbing
Comas Piping
City of Tukwila
MILTING DIVISION
REVISIONS
No changes shall be made to the scope
• of work without prior approval of
Tukwiia Building Division.
NOT71 f 'n„ ^;'?n5 will rquire ,a new r1an a!br±i43.71
` n ..y : -' .,'..:::10 4c iorlai rlE n r'. , , :
FAN
ID
ULF
501117
ID
BRAND NAME
MODEL NUMBER
CFM
SP
HP /AMP
FLOW
V /PH
SOUND RATING
DUCT
LOCATION
EF -1,2
ILG
CR5Al2 -1/4
1,400
.125
1/4
CV
115/14)
10.2
14x14 511
WAREHOUSE
FILE COPY
Permit No.
Plan review approval is subject to errors and omissions.
Ap roval of construction documents does not authorize
14c v olation of any adopted code or ordinance. Receipt
o' approved Field Copy and con o is acknowledged:
GAS UNIT kF4THR SCkEULLE
ID
BRAND NAME
MODEL NUMBER
CFM
Btuh INPUT
Btuh OUTPUT
EFFICIENCY
GAS
GAS
CONNECTION
V
OUT
OUTLET
V /PH
FLA
WT.
UH -1,2
REZNOR
UDAP -200
2,562
200,000
166,000
83%
1/2 "4)
5 "•
120/14)
5
181 LBS.
NOTE: These plans are diagrammatical only.
Please verify all dimensions at job site.
By
Date:
I
1c.
ity Of Tiukwila
BUILDING DIVISION
--0,2,,„,octaii-- Th. b.e set Log-gt
ax/.0.cAkr, ■t « AG 1 T
mou.Nf rl no 1 owev• -Puts" �'ke htaf ;; to
REVIEWED FOR
CODE COMPLIANCE
APDKOVED
NUV 3 0 2010
�J
')1(
City of Tukwila
BUILDING DIVISION
1 --1VAC LEGENED
1. DUCT INSULATION SHALL MEET
INLINE EXHAUST FAN(5)
0 i
2. SMOKE DETECTOR(S) INSTALLED IN
i
SECTION 606 OF THE 2010 IMC.
INVAC SMOKE DUCT DETECTORS
SHALL SHUT DOWN POWER TO THE
UNiT UPON ACTIVATION AND, A
ROOFTOP EXHAUST FAN
INITIATED AT THE FIRE ALARM
PANEL UPON SMOKE DUCT DETECTOR
ACTIVATION. IMC SECTION 6062.1.
3. DUCTWORK- MAINTRUNK IS R -42 IN
CONDITIONED SPACES AND R -8 IN
UNCONDITIONED SPACES AS PER THE
IiiSiDEWALL
4. ALL SINGLE PACKAGE HVAC UNITS
EXHAUST FAN
ERS PER MANUFACTURER'S INSTALL-
n
SECTION 403, CHAPTER 6, AND SHALL
VAV FAN 5OX
C
5. EQUIPMENT INSTALLATION
1
INSPECTIONS.
6. ALL HVAC EQUIPMENT TO BE LABELED
-TO THE SPACE SERVED.
1. DUCTS TO 5E SUPPORTED AT EACH
DIRECTION CHANGE - VERTICAL AT
12'-0" MAX., HORIZONTAL AT 10'-0"
CEILING EXHAUST FAN
TRAPEZE SUPPORT.
r
AND SEVEN DAY TYPE, WITH 5 DEGREE
DEADBAND.
GAS METER
COMPLETE WHEN ALL SECTIONS OF
ZD12
'PHIS SHALL INCLUDE AS -BUILT DRAW-
VVT DAMPER
SYSTEM BALANCE REPORT, AND A
COMMISSIONING REPORT.
10.DUCT SEALING SHALL MEET REQUIRE -
0
THERMOSTAT
AT PRESSURES ABOVE 1/2" WATER
COLUMN STATIC PRESSURE SHALL 5E
SEALED IN ACCORDANCE WITH
T -SAR SUPPLY DIFFUSER
ING IS AS FOLLOWS:
L STATIC PRESSURE: 1/2" TO 2";
SEAL TRANSVERSE JOINTS.
2. STATIC PRESSURE 2: 2" TO 3 ";
SEAL ALL TRANSVERSE JOINTS
AND LONGITUDINAL SEAMS.
3. STATIC PRESSURE: ABOVE 3 ";
SEAL ALL TRANSVERSE JOINTS,
LONGITUDINAL SEAMS, AND DUCT
WALL PENETRATIONS.
11. NREC FORMS, DUCTING PLANS
T -EAR RETURN GRILLE
VIAQ INFORMATION IS REQUIRED
ALONG WITH A MECHANICAL PERMIT
AT THE TIME OF THE TENANT
IMPROVEMENT PERMIT.
12. PIPING INSULATION SHALL MEET THE
REQUIREMENTS OF 1415 OF THE WSEC:
TABLE 14-8
MINIMUM PIPE INSULATION (INCHES)
FLUID DESIGN
INSULATION CONDUCTMiY
INAL PIPE DIAMETER IN.)
OPERATING TEMP.
GONDUCTMiY RANGE
HARDLID SUPPLY DIFFUSER
RUNOUTS'
//
> 4 TO 8
> 8
RANGE 'F
Btu- in/h -FT2- F
I TEMP. 'F
UP TO 2 J
HARDLID RETURN GRILLE
J
HEATING SYSTBAS
(STEM, CONDENSATE AND HOT WATER)
NOMINAL INSULATION THICKNESS
ABOVE 350
CEILING RADIATION
DAMPER ABOVE DIFFUSER
250
1.5
2.5
1
3.0
MI
3.5
251 -350
0.29 -0.31
200
1.5
2.0
2.5
2.5
3.5
CEILING RADIATION
DAMPER ABOVE GRILLE
201 -250
0.27 -0.30
150
1 i
1.5
L_J
2.0
FD ►-
FIRE DAMPER
FSD
FIRE SMOKE DAMPER
125
VOLUME DAMPER
q 6
1.5
SDI-
SMOKE DETECTOR
-"......w....,- •.„
FLEXIBLE DUCT SA /RA
0.24-0.28 0.24 -0.28
ROUND DUCT UP
1.5
1.0
1.0
1
1
ROUND DUCT DOWN
1.5
ESTIC WATER
ACCESS PANEL
I 100 1 0.5 1 1.0 I 1.0 I 1.5 1 1.5 1 1.5
A
P
(CH X55
0.23-021
40xigivier?4,)
SUPPLY AIR DIFFUSER
0.5
RETURN AIR GRILLE
RAG\
/24600
Cx24 FM -12 �
`
( RTU -1 )
ROOFTOP UNIT
75
. EXHAUST FAN
( EF -1 )
I 1.5
( SF -1
SUPPLY FAN
11.0
1.5
( UH -1 )
UNIT HEATER
CONDENSING UNiT
( CU -1 )
HP -1 )
HEAT PUMP
AC -1 )
AIR CONDITIONING UNIT
AIR HANDLING UNIT
( AHU -1 )
( IR1-1-1 )
INFRARED HEATER
--0,2,,„,octaii-- Th. b.e set Log-gt
ax/.0.cAkr, ■t « AG 1 T
mou.Nf rl no 1 owev• -Puts" �'ke htaf ;; to
REVIEWED FOR
CODE COMPLIANCE
APDKOVED
NUV 3 0 2010
�J
')1(
City of Tukwila
BUILDING DIVISION
CONTRACTOR'S LICENSE NUMBER: INNER 1591*
AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141
SEATTLE: (253) 839 -2126 FAX: (283) 135 -3432
P.O. Box 614 - AUBURN, WASHINGTON 98071
@ UNIVERSAL REFRIGERATION DRAWING -200t
PRINT /PLOT DATE:
I-1VAC NOTES
1. DUCT INSULATION SHALL MEET
REQUIREMENTS OF SECTION 14142 OF
THE 2006 WSEC AND TABLE 14 -5.
2. SMOKE DETECTOR(S) INSTALLED IN
MAIN RETURN AIR DUCTS AS PER
SECTION 606 OF THE 2010 IMC.
INVAC SMOKE DUCT DETECTORS
SHALL SHUT DOWN POWER TO THE
UNiT UPON ACTIVATION AND, A
"SUPERVISORY" ZONE SHALL 5E
INITIATED AT THE FIRE ALARM
PANEL UPON SMOKE DUCT DETECTOR
ACTIVATION. IMC SECTION 6062.1.
3. DUCTWORK- MAINTRUNK IS R -42 IN
CONDITIONED SPACES AND R -8 IN
UNCONDITIONED SPACES AS PER THE
WSEC.
4. ALL SINGLE PACKAGE HVAC UNITS
SHALL 5E INSTALLED WITH ECONOMIZ-
ERS PER MANUFACTURER'S INSTALL-
ATION INSTRUCTIONS PER I.M.C. 2010,
SECTION 403, CHAPTER 6, AND SHALL
OPERATE, PER W.S.E.C. 2006, SECTION
1413.
5. EQUIPMENT INSTALLATION
INSTRUCTIONS TO 5E ON SITE FOR
INSPECTIONS.
6. ALL HVAC EQUIPMENT TO BE LABELED
-TO THE SPACE SERVED.
1. DUCTS TO 5E SUPPORTED AT EACH
DIRECTION CHANGE - VERTICAL AT
12'-0" MAX., HORIZONTAL AT 10'-0"
-MAX. WITH STRAP, OR 8' -0" MAX. F
TRAPEZE SUPPORT.
8. THERMOSTAT TO HAVE NIGHT SETBACK
AND SEVEN DAY TYPE, WITH 5 DEGREE
DEADBAND.
9. THE HVAC INSTALLATION SHALL. 5E
COMPLETE WHEN ALL SECTIONS OF
1416 WSEC HAVE BEEN SATISFIED.
'PHIS SHALL INCLUDE AS -BUILT DRAW-
INGS, SUBMITTALS, 04M MANUALS,
SYSTEM BALANCE REPORT, AND A
COMMISSIONING REPORT.
10.DUCT SEALING SHALL MEET REQUIRE -
MENTS OF WSEC 1414.1. DUCT WORK
WHICH IS DESIGNATED TO OPERATE
AT PRESSURES ABOVE 1/2" WATER
COLUMN STATIC PRESSURE SHALL 5E
SEALED IN ACCORDANCE WITH
STANDARD R8-18. EXTENT OF SEAL-
ING IS AS FOLLOWS:
L STATIC PRESSURE: 1/2" TO 2";
SEAL TRANSVERSE JOINTS.
2. STATIC PRESSURE 2: 2" TO 3 ";
SEAL ALL TRANSVERSE JOINTS
AND LONGITUDINAL SEAMS.
3. STATIC PRESSURE: ABOVE 3 ";
SEAL ALL TRANSVERSE JOINTS,
LONGITUDINAL SEAMS, AND DUCT
WALL PENETRATIONS.
11. NREC FORMS, DUCTING PLANS
(BALANCING FEATURES) AS WELL AS
VIAQ INFORMATION IS REQUIRED
ALONG WITH A MECHANICAL PERMIT
AT THE TIME OF THE TENANT
IMPROVEMENT PERMIT.
12. PIPING INSULATION SHALL MEET THE
REQUIREMENTS OF 1415 OF THE WSEC:
TABLE 14-8
MINIMUM PIPE INSULATION (INCHES)
FLUID DESIGN
INSULATION CONDUCTMiY
INAL PIPE DIAMETER IN.)
OPERATING TEMP.
GONDUCTMiY RANGE
MEAN RATING
RUNOUTS'
1 AND p1 TO 2 2 TO
> 4 TO 8
> 8
RANGE 'F
Btu- in/h -FT2- F
I TEMP. 'F
UP TO 2 J
LESS 1 1
J
HEATING SYSTBAS
(STEM, CONDENSATE AND HOT WATER)
NOMINAL INSULATION THICKNESS
ABOVE 350
0.32 -0.34
250
1.5
2.5
2.5
3.0
3.5
3.5
251 -350
0.29 -0.31
200
1.5
2.0
2.5
2.5
3.5
3.5
201 -250
0.27 -0.30
150
1.0
1.5
1.5
2.0
2.0
3.5
141 -200
0.25 -0.29
125
0.5
1.5
1.5
1.5
1.5
1.5
105-140
0.24-0.28 0.24 -0.28
100
1.5
1.0
1.0
1.0
1.5
1.5
ESTIC WATER
105 MATER 10.24-0.28
I 100 1 0.5 1 1.0 I 1.0 I 1.5 1 1.5 1 1.5
COOLING SYSTEMS
(CH X55
0.23-021
75
0.5
0.5
0.75
1.0
1.0
BELOW 40
0.23 -0.27
75
1.0
I 1.0
I 1.5
I 1.5
I 1.5
11.0
1.5
CONTRACTOR'S LICENSE NUMBER: INNER 1591*
AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141
SEATTLE: (253) 839 -2126 FAX: (283) 135 -3432
P.O. Box 614 - AUBURN, WASHINGTON 98071
@ UNIVERSAL REFRIGERATION DRAWING -200t
PRINT /PLOT DATE:
159
11/2/10
PROJECT START DATE:
11/2/10
DRAFTER:
DESIGNER:
PROJECT MANAGER:
JOB NUMBER:
10218
SHEET NUMBER:
SCOPE OF WORK
JOB #1218
I. INSTALL (2) EXHAUST FANS.
2. INSTALL (2) GAS-FIRED UNIT HEATERS.
3. INSTALL VENT DUCTWORK.
4. INSTALL NATURAL GAS PIPING.
159
11/2/10
PROJECT START DATE:
11/2/10
DRAFTER:
DESIGNER:
PROJECT MANAGER:
JOB NUMBER:
10218
SHEET NUMBER:
PENDING CITY APPROVAL)
PLA ED EQUID STANT
E.S.F. SPRINKL _ -1 EARS
1 4 CAP
u
■
■
1"4) AT. c AS
II
STANT
R NEARS
IS-VENT
4'-!4).- NAT —GAS
NAT.IC AS
NMI
NOTE: These plans are diagrammatical only.
Please verify all dimensions at job site.
■
I-IVAC FLAN AND NAT. CHAS PIPING FLAN
SCALE: 3/32" = 1 -0"
REVIEWED FOR
CODE COMPLIANCE
L P1DMVED
Na 6 0 2010
City of Tukwila
BUILDING nivisim
1 -1/2 ". N
T. GAS 6 5 LBS. PRES URE
'2[11Z-Ea400a
-AIR CCNDItIONING - NEAT FJIF$ - Rl RIGERATION-
CONTRACTOR'S LICENSE NUMBER: UNIVERI 1591*
AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141
SEATTLE: (253) 839 -2126 FAX: (253) 133 -3432
P.O. 50X 614 - AUBURN, WASHINGTON 98011
@ UNIVERSAL REFRIGERATION DRAWING -2001
z
0
0
0
(1)
w
0
z
_0
w
cc
w
(A
1-
CC
w
0
w
Q
0
0
CO
w
cc
0
a
a
w
cr)
O
w
w CC
U Lj
W Z
0
CC UD
W
a
w
w
m
cry
RECEIVED
NOV 15 2010 C/7
I'P ICRf Tf'DATE:
co
00
TM
00
0)
z
0
CD
z
U
w
CC
Q
Q
CC
w
N
11/2/10
PROJECT START DATE:
11/2/10
DRAFTER:
CFN
DESIGNER:.
JLA
PROJECT MANAGER:
BG
JOB NUMBER:
10218
SHEET NUMBER:
M -1
FREEZE PROTECTION CALCULATION
EQUIPMENT OUTPUT TOTAL
STUN
_ = /SQ. FT.
- WAREHOUSE SQUARE FOOTAGE
(2) UNIT HEATERS x (166,000) STUN OUTPUT
42,198 SQ. FT. = 13TUN /SQ. FT.
332,000 �TUI -I
_
- 41,298 SQ. FT. = 1.�5 STUN /SQ. FT.
'2[11Z-Ea400a
-AIR CCNDItIONING - NEAT FJIF$ - Rl RIGERATION-
CONTRACTOR'S LICENSE NUMBER: UNIVERI 1591*
AUBURN: (253) 939 -5501 TACOMA: (253) 922 -3141
SEATTLE: (253) 839 -2126 FAX: (253) 133 -3432
P.O. 50X 614 - AUBURN, WASHINGTON 98011
@ UNIVERSAL REFRIGERATION DRAWING -2001
z
0
0
0
(1)
w
0
z
_0
w
cc
w
(A
1-
CC
w
0
w
Q
0
0
CO
w
cc
0
a
a
w
cr)
O
w
w CC
U Lj
W Z
0
CC UD
W
a
w
w
m
cry
RECEIVED
NOV 15 2010 C/7
I'P ICRf Tf'DATE:
co
00
TM
00
0)
z
0
CD
z
U
w
CC
Q
Q
CC
w
N
11/2/10
PROJECT START DATE:
11/2/10
DRAFTER:
CFN
DESIGNER:.
JLA
PROJECT MANAGER:
BG
JOB NUMBER:
10218
SHEET NUMBER:
M -1