HomeMy WebLinkAboutPermit M10-160 - SABEYSABEY 3355 S 120 PL M10 -160 City PTukwi1a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Project Name: SABEY Permit Number: M10 -160 Issue Date: 12/02/2010 Permit Expires On: 05/31/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: EASA NOUROUZEE Address: 5005 3 AV S , SEATTLE WA 98134 Email: EASAN @MCKINSTRY.COM Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98134 Contractor License No: MCKINCL942DW Phone: 206 391 -6926 Phone: 206 762 -3311 Expiration Date: 03/16/2012 DESCRIPTION OF WORK: INSTALL (1) VFD CONTROLLED RETURN FAN, ASSOCIATED SUPPLY /RETURN DUCT, DAMPERS, AND MIXING PLENUM TO SERVE DATA CENTER EXPANSION SPACE 5201B. Value of Mechanical: $93,050.00 Fees Collected: $1,248.06 Type of Fire Protection: SPRINKLERS /AFA International Mechanical Code Edition: 2009 Permit Center Authorized Signature: tu..11[-Z1. Date: 12-- )--Id I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: L/ 2_/ o This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -160 Printed: 12 -02 -2010 • • PERMIT CONDITIONS Permit No. M10-160 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: IMC -4110 M10-160 Printed: 12 -02 -2010 (206)575 -4407. • • doc: IMC -4/10 M10-160 Printed: 12 -02 -2010 CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tkwila. wa. us Mechanical Permit No. to-No Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 3355 S 120th Place Tukwila, WA 98168 Tenant Name: Sabey Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwila Intl. BLVD. 4th Floor King Co Assessor's Tax No.: 1023049082 Suite Number: 5201 B Floor: 2 New Tenant: ❑ Yes .. No Seattle WA 98168 Zip City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Easa Nourouzee Mailing Address: 5005 3rd Ave S. Day Telephone: (206) 391 -6926 Seattle WA 98134 E -Mail Address: easan @mckinstry.com City State Fax Number: (206) 716 -3224 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: McKinstry Co. Mailing Address: 5005 3rd Ave S WA 98134 Contact Person: Tony Marino E -Mail Address: tonym @mckinstry.com Contractor Registration Number: MCKINCL942DW City State Day Telephone: (206) 650 -4956 Fax Number: (206) 831 -8662 Expiration Date: 03/16/2012 Zip ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD — All'plans must be stamped by engineer of record Company Name: McKinstry Co. Mailing Address: 5005 3rd Ave S Contact Person: Tony Marino WA 98134 E -Mail Address: tonym @mckinstry.com H:\ Applications \Forms- Applications On Line \2010 Applications \7 -2010- Mechanical Permit Application.doc Revised: 7 -2010 t.t. City State Day Telephone: (206) 832 -8462 Fax Number: (206) 832 -8662 Zip Page 1 of 2 Staff Initials: t-7,1--- I Valuation of project (contractor's bid price): $ 93,050 Scope of work (please provide detailed information): Install (1) VFD controlled return fan, associated supply /return duct, dampers and mixing plenum to serve data center expansion space 5201 B. Use: Residential: New ❑ Replacement Commercial: New 0 Replacement ❑ Fuel Type: Electric Gas ❑ Other: 3 Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment 3 air handling unit <10,000 cfm incinerator — comm/ind PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A J RIORIZED AGENT: Signature: Print Name: 1=asa Nourouzee Mailing Address: 5005 3rd Ave S Date: 11/16/2010 Day Telephone: (206) 391 -6926 Seattle City WA 98134 State Zip Date Application Accepted: It, U t t2 Date Application Expires: H:\Applications \Forms - Applications On Line\2010 Applications \7-2010 - Mechanical Permit Application.doc Revised: 7 -2010 Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htqx//www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY RECEIPT Permit Number: M10 -160 Status: APPROVED Applied Date: 11/16/2010 Issue Date: Receipt No.: R10 -02414 Initials: User ID: Payee: WER 1655 Payment Amount: $998.45 Payment Date: 12/02/2010 10:14 AM Balance: $0.00 MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11301 998.45 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 998.45 Total: $998.45 doc: Receiot -06 Printed: 12 -02 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htlx//www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY RECEIPT Permit Number: M10 -160 Status: PENDING Applied Date: 11/16/2010 Issue Date: Receipt No.: R10 -02318 Payment Amount: $249.61 Initials: JEM Payment Date: 11/16/2010 11:53 AM User ID: 1165 Balance: $998.45 Payee: MCKINSTRY CO. SERVICE ACCOUNT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11181 249.61 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 249.61 Total: $249.61 doc: Receiot -06 Printed: 11 -16 -2010 Retain a copy .with perAnit, 041 .. . 1NS11 GTION NO. "' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (2— 1 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 48 e y Type Inspectiioonn: of a - Address: i?l 335 s 5. I2-o I L Date Called r^ /`'��l _ _ Special Instructions: (9L-- �� - / Date Wanted: a.m. -� 3 - 1/ p.m. Requester: Phone No: / - u(o -`7 5S -4550 Approved per applicable codes. Corrections required prior to approval. COMMENTS: QTM:l e iLDlc A Inspecto( ,1(A„ Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy y with permit A4.!. 0 _ �`�-00 L . p P PERMIT NO. .., CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 INSPECTION NO. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project Type of Inspection: QJ (.am( ,T:.) 1 n Ad^d�r s a ` 12,0,0- � Date Called: Special Instructions: Z/' • Date Wanted: / J^'"" -tea i.... ( i • p.m. Requester: Phone No Phone ( - Z SS x,3(0') 1 • Approved -per applicable codes. ElCorrections required. prior to approval. COMMENTS: • .' Inspec • Date: ri REINSPECTION FEE REQUIRE ' . P for to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. : .INSPECTION RECORD Retain a copy with permit Id --10 INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =30 Permit Inspection Request Line (206) 431 -2451 • Pro S Type of Inspection: j - Address: 333S r ?,v PL Date Called: Special Instructions: Date Wanted: _....-- a.m.. i p.m. Requester: Phone No: 7 ,0 (0 - 255347( Approved per applicable codes. COMMENTS: Corrections required prior to approval. 4. Inspe Ct0 . Date: 1 — - !� n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. •• • • -- INSPECTION RECORD Retain a copy with permit am( /r7 ✓6 --141) INSPECTION NO. • PERMIT N0. CITY OF TUKWILA BUILDING DIVISION tr)-" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projecttt: :� rN{ %�/� Type of Inspection: Address: 3. 6' )1.20 PL Date Called: Special Instructions: . Date Wanted: f_ --z 6 — / / CO- P.M. Requester: Phone No: EiApproved per applicable codes. COMMENTS: Corrections required prior-to approval. p, - • ;FAVT"-* flPtd VA" • 111.i'4tip_ r Ms! w 1 c,► 1 — L t } ' + Act ip Lit %, Inspectq(i! 1. I .r.74 .#N 'REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ' •. INSPECTION NUM "27;27c il Instructions: - ‘- Needs Shift Insf)ediork: 1 Sp nkiers: I Alarm: Monitor: ..,1 u Permits: Type: Occupancy Fire invoice from Tuicwile Rut= Department. Call to Word/Inspection Record FoM1.00c 1/1,3/06 T.F.D. Form F.P. 113 • PERMI7 COORD CO10 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -160 DATE: 11/16/10 PROJECT NAME: SABEY SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued L. DEPARTMENTS: \ Di ision Public Works Am kWc n M -1'7) hire Prevention Planning Division EI ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete UL Comments: Incomplete n DUE DATE: 11/18/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route % Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/16/10 Approved Approved with Conditions Xi Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pinter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MCKINSTRY CO LLC UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State WA Expiration Date 3/16/2012 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JLLYDIG+ MCKINSTRY LLC Construction Contractor General Unused 4/13/2010 4/13/2012 Active WESTVI'121RF WESTVENT INC Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN "372ND MCKINSTRY CO Construction Contractor General Unused 8/20/1963 1/2/2008 Re- Licensed Business Owner Information Name Role Effective Date Expiration Date PEDERSEN, JAMIE D Agent 03/16/2006 Bond Amount ALLEN, DEAN CHARLES Partner /Member 03/16/2006 929511574 MOORE, DOUGLAS JAMES Partner /Member 03/16/2006 ALLEN, DAVID EDWARD Partner /Member 03/16/2006 TRAVELERS CAS & SURETY CO TEPLICKY, JOSEPH WILLIAM Partner /Member 03/16/2006 03/01/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 WESTERN SURETY CO 929511574 09/09/2010 Until Cancelled $12,000.0009/02 /2010 1 TRAVELERS CAS & SURETY CO 104702039 01/03/2006 Until Cancelled 03/01/2011 $12,000.0003/16 /2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009 01/31/2011 $2,000,000.0012 /07/2009 2 ZURICH AMERICAN INS CO CP03999903 01/31/2008 01/31/2009 52,000,000.00 01/31/2008 1 CHARTER OAK FIRE INS CO DTC052D7193C0F07 01/31/2006 01/31/2009 $1,000,000.00 01/08/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lnifbbip/Print.aspx 12/02/2010 12x12 2 "SL — ABBREVIATIONS PIPING IDENTIFICATION GENERAL AD ADJ AFF AFG AG AMP ARCH AUTO AUX BD BHP BLDG BOP BOT es BTU BTUH CA CAB COND C/L CLG CFM CLG CO CO2 COL CONC COND CONN CONSTR CON1R CTL DET DIA DIAL DIM DISCH DP/ DN DS DWDI DWG DWV EA EC EL ELEC ELEV EP EQUIP ESP EXH EXIST (F) FA FCO FDC FDN FIG FIN FIO FLEX FLG RR FO FP M Fr FTG FURN GA GALV GC GEN GPM GWB HP HR HS HTG HTR ID LAB LF MAU MAX MBH MED MEZZ MFR MH MIN MISC MTD N/A NC NEG NIC NO NOM NTS OA OC OD OVHD POC PRELIM PSI PSIG QTY R RAD REQD RPM SECT SF SIM SPEC SQ STD STRUC ACCESS DOOR ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE GROUND AMPERE ARCHITECT; ARCHITECTURAL AUTOMATIC AUXILIARY BOARD BRAKE HORSEPOWER BUILDING BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRIITSH THERMAL UNITS PER HOUR COMPRESSED AIR CABINET CONDENSATE CENTER UNE CEILING CUBIC FEET PER MINUTE CEILING CARBON MONOXIDE CARBON DIOXIDE COLUMN CONCRETE CONDENSER; CONDENSATE CONNECT; CONNECTION CONSTRUCTION CONTRACTOR CONTROL DETAIL DIAMETER DIAGONAL DIMENSION DISCHARGE DMSION DOWN DISCONNECT SWITCH; DOOR SWITCH DOUBLE WIDTH, DOUBLE INLET DRAWING DRAIN, WASTE, VENT EXISTING EACH ELECTRICAL CONTACTOR; END CAP ELEVATION ELECTRICAL ELEVATION ELECTRICAL PANEL; END PLUG EQUIPMENT EXTERNAL STATIC PRESSURE EXHAUST EXISTING FUTURE FAHRENHEIT FIRE ALARM FLOOR CLEANOUT FIRE DEPARTMENT CONNECTION FOUNDATION FIGURE FINISH FURNISHED AND INSTALLED BY OWNER FLEXIBLE FLANGE FLOOR FUEL OIL FIRE PROTECTION FEET PER MINUTE FOOT; FEET FOOTING FURNISH GAGE GALVANIZED GENERAL CONTRACTOR GENERATOR GALLONS PER MINUTE GYPSUM WALL BOARD HIGH HORSEPOWER; HIGH PRESSURE HEATING RETURN HEATING SUPPLY HEATING HEATER INSIDE DIAMETER /DIMENSION LABORATORY LINEAL FOOT MAKE —UP AIR UNIT MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MEDIUM MEZZANINE MANUFACTURER MANHOLE MINIMUM; MINUTE(S) MISCELLANEOUS MOUNTED NOT APPLICABLE NORMALLY CLOSED NEGATIVE NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OVERHEAD POINT OF CONNECTION PRELIMINARY POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANTITY RELOCATED RADIUS REQUIRED REVOLUTIONS PER MINUTE SECTION SQUARE FOOT SIMILAR SPECIFICATION SQUARE STANDARD STRUCTURAL TBD TOC TOS TYP UG UNO VAV VD VER VFD VSD W/ W/O HVAC AC ACT AHU BDD BOD CC CRU CT CV DB DIFF DMPR EA EAT ECG EF FCU FD FM FP FTU TO BE DETERMINED TENANT IMPROVEMENTS TOP OF CONCRETE TOP OF STEEL TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE VARIABLE AIR VOLUME VOLUME DAMPER VERIFY VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE WITH WITHOUT AIR CONDITIONING ACOUSTICAL CEILING 11LE AIR HANDLING UNIT BACKDRAFT DAMPER BOTTOM OF DUCT COOLING COIL COMPUTER ROOM UNIT COOLING TOWER CONSTANT VOLUME DRY BULB DIFFUSER DAMPER EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUST FAN FAN COIL UNIT FIRE DAMPER FREQUENCY MODULATION FIRE PROTECTION; FAN POWERED FAN TERMINAL UNIT GRD GRILLE, REGISTER, DIFFUSER HC HR HVAC HEATING COIL HEATING RETURN HEATING, VENTILATION AND AIR CONDIT ONING LAT LEAVING AIR TEMPERATURE LD LINEAR DIFFUSER MC MECH MOD MUA OA OBD RA RAT RCP RTU SA SAT SD SF S /FD SL SLSM SM SP TDH TG TOD TSP UH WB WC WG MECHANICAL CONTRACTOR MECHANICAL MOTOR OPERATED DAMPER; MODULATING MAKE UP AIR OVERALL; OUTSIDE AIR OPPOSED BLADE DAMPER RETURN AIR RETURN AIR TEMPERATURE REFLECTED CEILING PLAN ROOF TOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE SMOKE DAMPER SUPPLY FAN SMOKE FIRE DAMPER SOUND LINED SOUND LINED SHEET METAL SHEET METAL STATIC PRESSURE TOTAL DYNAMIC HEAD TRANSFER GRILLE TOP OF DUCT TOTAL STATIC PRESSURE UNIT HEATER WET BULB WATER COLUMN WATER GAUGE PLUMBING AD AREA DRAIN CO CLEAN OUT; CARBON MONOXIDE DCW DOMESTIC COLD WATER DHW DOMESTIC HOT WATER DHWC DOMESTIC HOT WATER RECIRCULATION DSP DRY STANDPIPE EWC ELECTRICAL WATER COOLER FD FLOOR DRAIN IE INVERT ELEVATION IN WC INCHES WATER COLUMN IW IONIZED WATER; INDIRECT WASTE NPCW NON POTABLE COLD WATER ORL OVERFLOW RAINWATER LEADER PD PLANTER DRAIN; PRESSURE DROP PERF PERFORATED PLBG PLUMBING PRV PRESSURE REDUCING VALVE RPBP REDUCED PRESSURE BACKFLOW PREVENTER SD STORM DRAIN SS SANITARY SEWER VTR VENT THROUGH ROOF W WASTE WC WATER CLOSET WH WATER HEATER WSP WET STANDPIPE PIPING BP CD CHW CHR CHS CT BACKFLOW PREVENTOR CONDENSATE DRAIN CHILLED WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CONICAL TEE EWT ENTERING WATER TEMPERATURE FHV FIRE HOSE VALVE LWT LEAVING WATER TEMPERATURE TOP TOP OF PIPE HVAC A COND CDR- CDS CHS —CHR- -HR— RL —RS ST PLUMBING GRW GAW ID IRR NP ORL rw PSD RWL RWL SD UD —V— w W FIRE PROTECTION' • DSP FDC FP WSP PIPING FITTINGS It! 0 D I+ . I$I I1- It VALVES 411 A 161 PIPING ACCESSORIES 4W 0 4 RPBP 1 Y 0 0 A COND CDR CDS CHS CHR G HR HS RL RS ST CW GRW GAW WIC ID IRR NPCW ORL PW PSD RWL RWL SD SS UD V W # WATTS /LF DSP FDC FP FW WSP COMPRESSED AIR PIPE CONDENSATE DRAIN PIPE CONDENSER WATER RETURN PIPE CONDENSER WATER SUPPLY PIPE CHILLED WATER SUPPLY PIPE CHILLED WATER RETURN PIPE NATURAL GAS PIPE HEATING WATER RETURN PIPE HEATING WATER SUPPLY PIPE REFRIGERANT LIQUID PIPE REFRIGERANT SUCTION PIPE STEAM SUPPLY COLD WATER PIPE (POTABLE) GREASE WASTE GARAGE WASTE HOT WATER PIPE (POTABLE) HOT WATER CIRCULATING (POTABLE) INDIRECT DRAIN IRRIGATION WATER PIPE NON — POTABLE CW PIPE OVERFLOW RAINWATER LEADER PUMPED WASTE PUMPED STORM DRAIN RAINWATER LEADER BELOW GRADE RAINWATER LEADER STORM DRAIN PIPE SANITARY SEWER PIPE (SITE) UNDERDRAIN PIPE VENT PIPE (SANITARY) WASTE PIPE WASTE PIPE BELOW GROUND DRY STAND PIPE FIRE DEPT. CONNECTION PIPE FIRE SPRINKLER PIPE FIRE PROTECTION WATER PIPE ARE PROTECTION WASTE PIPE WET STAND PIPE TEE W /PIPE UP TEE DOWN W /ELBOW TEE UP W/ ELBOW TEE UP TEE DOWN 90' ELBOW UP 90' ELBOW DN CAP UNION FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW CONCENTRIC REDUCER ECCENTRIC REDUCER SLOPE SYMBOL BREAK OR CONTNUAIION SYMBOL DOWN SPOUT NOZZLE CLEANOUT 45' ELBOW 45' ELBOW 90' ELBOW 90' ELBOW CROSS TEE WYE TAP HOSE CONNECTION MOTORIZED 2 —WAY VALVE MOTORIZED 3 —WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3 —WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VAVVE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3 —WAY GATE PLUG VALVE BALANCING VALVE HOSE BIBB PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR AUTO FLOW VALVE FLOW METER Y STRAINER Y STRAINER W/ BALI. VALVE PIPE SLEEVE STEAM TRAP PETES PLUG HEAT TRACING SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR FUNNEL DRAIN FLOOR DRAIN ROOF DRAIN ROOF OVERFLOW DRAIN AA!, AI ■11, DUCTWORK ACCESSORIES J =0 =T=3 rA LJ AD 12x12 SL R ri 6":: so DUCTWORK RECTANGULAR DUCT X SUPPLY AIR DUCT TURNING UP OR TOWARD BIRDSCREEN OR SCREENED OPENING SUPPLY GRILLE RETURN OR EXHAUST GRILLE VOLUME DAMPER MOTOR OPERATED DAMPER AIRFLOW MONITOR REMOTELY OPERATED VOLUME DAMPER (YOUNG REGULATOR OR APPROVED) BACK DRAFT DAMPER COORDINATE WITH CEIUNG APPURTENANCES. REX CONNECTION FIRE DAMPER THROUGH WALL FIRE DAMPER THROUGH FLOOR FIRE /SMOKE DAMPER THROUGH WALL FIRE /SMOKE DAMPER THROUGH FLOOR ACCESS DOORS 1" ACOUSTICALLY LINED DUCT 2" ACOUSTICALLY LINED DUCT CHANGE OF ELEVATION RISE(R) DROP(D) TRANSMON TURNING VANES SMOKE DETECTOR RETURN / EXHAUST / OUTSIDE AIR SUPPLY / TRANSFER AIR TERMINAL UNITS — SEE SCHEDULE FOR TYPE RECTANGULAR DUCT RECTANGULAR DUCT RECTANGULAR DUCT SUPPLY AIR DUCT TURNING DOWN OR AWAY EXHAUST OR RETURN AIR DUCT TURNING UP OR TOWARD EXHAUST OR RETURN AIR DUCT TURNING DOWN OR AWAY E:=6 ROUND DUCT TURNING UP OR TOWARD P LED ROUND DUCT TURNING DOWN OR AWAY OVAL DUCT TURNING UP OR TOWARD OVAL DUCT TURNING DOWN OR AWAY FLEXIBLE DUCT INSTRUMENTATION AND CONTROLS THERMOSTAT SENSOR CARBON MONOXIDE SENSOR VISUAL ALARM LIGHT — WALL MOUNTED GRILLE /REGISTER/DIFFUSER DOUBLE LINE s- X X 1 CEILING SUPPLY AIR DIFFUSER CEILING SUPPLY AIR DIFFUSER (SHOWN WITH' THROW ARROWS) CEILING RETURN, EXHAUST OR TRANSFER AIR GRILLE LINEAR DIFFUSER (CEILING) LINEAR DIFFUSER (WALL) LOUVER PLAN VIEW LOUVER (ELEVATION VIEW) HVAC - ANNOTATION DUCT WORK 0 ROUND DUCT SYMBOL $ FLAT OVAL DUCT SYMBOL GRILLE, REGISTER, OR DIFFUSER TAG DT5-618_ CFM EACH I SIZE TYPE CODE SEPARATE PERMIT REQUIRED FOR: D nechanical ectdcal PI mbing ',Tag Piping City of Tukwila BUILDING DIVISION, LD5 /3 -300 CFM EACH LINEAR DIFFUSER GRILLE 1 1 ACTIVE LENGTH IN FT. TOTAL LENGTH IN FT. TYPE CODE REVISIONS No changes shall bQ made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE C IPY Permit No. Plan review approval Is subject to errors and omissions. 47E)roval of construction documents does not authorize tt Ii, violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions Is acknowledged: By Date: 1 Ll Z 0 City Of lbkwila BUILDING DMSION LEGAL DESCRIPTION NE 1/4 OF THE SE 1/4 AND SE 1/4 OF THE SE 1/4 OF SECTION 9 AND GOVT LOT 15 AND SW 1/4 OF THE SW 1/4 OF SECTION 10, T23N., R4E., W.M. CITY OF TUKWILA, KING COUNTY, WASHINGTON. LOCATION / SITE MAP GENERAL INFORMATION SYMBOLS X X L - - --J 0 0 GENERAL NOTES: NEW MECHANICAL WORK FUTURE TI SCOPE & NEW WORK OTHER THAN MECHANICAL DEMO MECHANICAL WORK DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN PLAN NUMBER SHEET NUMBER WHERE, PLAN SHOWN REVISION NUMBER — DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD — DENOTES AREA OF CHANGE DETAIL REFERENCE OUTUNE WITH NUMBER AND SHEET LOCATION MATCHUNE PLUMBING FIXTURE CALL —OUT (SEE PLUMBING SCHEDULES) DRAWING NOTE REFERENCE POINT OF CONNECTION CENTERLINE STRUCTURAL BEAM PENETRATION (SEE M503) STRUCTURAL BEAM HAUNCH (SEE M503) 1. VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE ALL WORK PRIOR TO START OF CONSTRUCTION. 2. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS NOT PREVIOUSLY COORDINATED OR AGREED UPON, I.E. ANCHOR BOLT DEPTHS, ETC. 3. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. WHERE PROVIDED, REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS. 4. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS: A. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE OWNER (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.4.3) B. PROVIDE TO THE OWNER ALL NECESSARY SYSTEM OPERATION AND MAINTENANCE MANUALS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.4.2) C. BALANCE ALL HVAC SYSTEMS AND PROVIDE TO THE OWNER A WRITTEN BALANCING REPORT (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.2.1) D. EQUIPMENT /SYSTEMS TESTING SHALL BE PERFORMED IN ACCORDANCE WITH APPROVED PLANS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1). E. TEST, CALIBRATE AND ADJUST ALL HVAC CONTROLS AND SEQUENCES OF OPERATION IN ACCORDANCE WITH THE APPROVED PLANS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.2), NECESSARY TESTS ARE IDENTIFIED IN 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1; PREPARE A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.5.1); PROVIDE TO THE OWNER A FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.5.2). 5. PERFORMANCE OF ALL NEW BUILDING MECHANICAL SYSTEMS WILL COMPLY WITH OR EXCEED THE MINIMUM REQUIREMENTS AS SET FORTH IN THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1410 - GENERAL REQUIREMENTS. 6. MINIMUM VENTILATION QUANTITIES WILL COMPLY WITH OR EXCEED THE 2006 INTERNATIONAL MECHANICAL CODE. 7. ALL MOTORS WILL COMPLY WITH CHAPTER 15 OF THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SET. 8. ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED IN CHAPTER 14, TABLE 14 -5 OF THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE DUCTWORK AND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS DRAWING SET. 9. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. 10.FOR ADDITIONAL SYSTEM AND EQUIPMENT SEISMIC REQUIREMENTS, REFER TO STRUCTURA INFORMATION (WHERE PROVIDED) AND PROJECT SPECIFIC SEISMIC DESIGN INFORMATION SI CONTAINED WITHIN THIS DRAWING SET. DRAWING INDEX REVIEWED FOR CODE COMPLIANCE ArionnvED NOV 3 0 2010 City of Tukwila BUILDING DIVISION SHEET NUMBER SHEET TITLE MO.0 DRAWING INDEX, SYMBOLS AND ABBREVIATIONS MO.1 CONTROLS DIAGRAM AND SEQUENCE OF OPERATIONS MO.2 SEISMIC INFORMATION M2.2 2ND FLOOR HVAC PLAN M3.2 2ND FLOOR ENLARGED HVAC PLAN M4.0 HVAC SECTIONS & DETAILS M7.0 HVAC SPECIFICATIONS AND EQUIPMENT SCHEDULES RECEIVED CITY OF TUKWILA NOV 16 2010 PERMIT CENTER p\10 ftoO For Th irtstr y ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503- 331 -0234 www.mckinstry.com PROJECT: SABEY DATA CENTER SDC 5201B 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING TONY MARINO BEV PATTERSON BILL DAGGEIT 11 -12 -10 SEE DRAWING SHEET TITLE: DRAWING INDEX, SYMBOLS, AND ABREVIATIONS SHEET NUMBER: M0.0 PROJECT: SABEY SDC52O1 -B ITEM: SEQUENCE OF OPERATIONS SCOPE OF WORK FOR THIS PROJECT IS TO EXTEND THE EXISTING SUPPLY AIR, RETURN/EXHAUST AIR SYSTEMS TO THE 5201 -B SUITE. PROVIDE THE TEMPERATURE CONTROL AND ALARMING TO SUPPORT THE HVAC SYSTEM. DESIGN CRITERIA: 72 °F TEMPERATURE AND 30 -70% RELATIVE HUMIDITY IN FLOOR SPACE. RUN CONDITIONS: THE CONTROLLER WILL CONTROL TO MAINTAIN SUPPLY AIR TEMPERATURE AND STATIC PRESSURE TO THE SPACE CONTINUOUSLY. SUPPLY AIR DESCRIPTION: EXISTING SUPPLY AIR IS PROVIDED TO THE SPACE FROM THE CENTRAL PLANT AIR HANDLING EQUIPMENT LOCATED ON THE 3Pc FLOOR. THE EXISTING DUCT MOUNTED FLOW MEASURING DEVICE WILL MONITOR THE AIRFLOW TO BOTH SDC5201A AND SDC5201B- A NEW FLOW MEASURING DEVICE WILL MEASURE THE AIRFLOW TO SDC5201B ONLY. 5 NEW ROOM DIFFERENTIAL PRESSURIZATION SENSORS SHALL AVERAGE THE DIFFERENTIAL PRESSURE (BETWEEN THE DATA FLOOR SPACE AND THE CORRIDOR) AND WILL MODULE THE DAMPERS IN THE SUPPLY DUCTWORK TO MAINTAIN ROOM DIFFERENTIAL PRESSURE SETPOINT. NEW (5) ROOM TEMPERATURE SENSORS WILL BE UTILIZED TO MODULATE THE RETURN AIR DAMPER FOR SUITE 5201B TO MAINTAIN THE ROOM TEMPERATURE SETPOINT OF 72°F (ADJ.). AIRFLOW TO SUITE: THE EXISTING AND NEW AIRFLOW MONITORING STATION SHALL MONITOR THE SUPPLY AIR FLOW. ALARMS WILL BE PROVIDED AS FOLLOWS: • AIRFLOW FAILURE: THE MEASURED AIRFLOW IS BELOW THE ALARM SETPOINT (ADJ.). SPACE CONDITIONS: THE CONTROLLER WILL MONITOR THE NEW (5) SPACE TEMPERATURE/ HUMIDITY SENSORS IN THE SUITE. THE SENSORS ARE WALL MOUNTED SENSORS AND WILL BE INSTALLED AT OWNER DESIGNATED LOCATIONS. THE CONTROLLER WILL UTILIZE THE SENSORS BY AN OPERATOR SELECTED METHOD FOR SPACE CONTROLLER. MODES: • AVERAGE OF ALL (5) SENSORS • HIGHEST TEMPERATURE OF ALL (5) SENSORS • INDIVIDUAL SENSOR SELECTION (I.E. SENSOR #1, SENSOR #2, ETC.) IF A SENSOR HAS FAILED (I.E. SENSOR VALUE REFLECTING SENSOR FAILURE), THE CONTROLLER WILL REMOVE IT FROM THE AVERAGING CALCULATION. IF THE FAILED SENSOR IS BEING UTILIZED FOR SPACE CONTROL, THE CONTROLLER WILL UTILIZE AN AVERAGE OF THE REMAINING SENSORS. ALARMS WILL BE PROVIDED AS FOLLOWS: • SENSOR #X FAILURE: THE SENSOR IS OUTSIDE OF ACCEPTABLE OPERATING CONDITIONS. • SENSOR #X HIGH TEMPERATURE: THE SPACE TEMPERATURE IS GREATER THAN 76 "F (ADJ.). • SENSOR #X LOW TEMPERATURE: THE SPACE TEMPERATURE IS BELOW G6 °F (ADJ.) • SENSOR #X HIGH HUMIDITY: THE SPACE HUMIDITY IS GREATER THAN THE 70 %RH (ADJ.). • SENSOR #X LOW HUMIDITY: THE SPACE HUMIDITY IS BELOW THE 30 %RH (ADJ.). SUPPLY AIR TEMPERATURE SETPOINT - FIXED: THE CONTROLLER WILL MONITOR THE SUPPLY AIR TEMPERATURE AND WILL MAINTAIN A FIXED SUPPLY AIR TEMPERATURE SETPOINT OF 72 °F (ADJ.). THE CONTROLLER WILL MODULATE THE RETURN AIR DAMPER (FROM SUITE) TO MAINTAIN THE SUPPLY AIR TEMPERATURE TO THE SUITE. ALARMS WILL BE PROVIDED AS FOLLOWS: • HIGH SUPPLY AIR TEMP: IF THE SUPPLY AIR TEMPERATURE 15 5 °F (ADJ.) GREATER THAN SETPOINT. SPACE PRESSURE THE CONTROLLER WILL MEASURE SPACE STATIC PRESSURE BETWEEN THE SPACE AND THE COMMON CORRIDOR. THE CONTROLLER WILL MODULATE THE SUPPLY DAMPER TO MAINTAIN A POSITIVE SPACE STATIC PRESSURE SETPOINT OF 0.05IN H2O (ADJ. RANGE 0.025' TO 0.10"). ALARMS WILL BE PROVIDED AS FOLLOWS: Sabey: SDC5201 -B Page 1 of 1 11 -12 -10 • LOW STATIC PRESSURE: IF THE SPACE PRESSURE DROPS BELOW THE SETPOINT. IF THERE IS A LOSS OF ACCEPTABLE PRESSURE READING. THE CONTROLLER WILL MAINTAIN LAST COMMAND SIGNAL AND INITIATE AN ALARM. RETURN FANS (EXISTING RF -5201A 5201 B. 5201C, AND NEW RF -5201 D): EACH FAN RUNS CONTINUOUSLY. ONE FAN IS REDUNDANT. RETURN AIR DESCRIPTION: THE RACK MOUNTED SERVERS IN THE FLOOR SPACE ARE EQUIPPED WITH PLENUMS THAT ROUTE THE HOTAIR FROM THE SERVER TO THE CEILING PLENUM. DIFFERENTIAL PRESSURE SENSORS BETWEEN THE ROOM AND CEILING PLENUM WILL MODULATE THE RETURN FAN VFDS TO MAINTAIN A NEGATIVE PRESSURE SETPOINT OF - 0.01IN H7O (ADJ. RANGE 0.0' TO -0.10'). RUN CONDITIONS THE CONTROLLER WILL COMMAND THE (4) RETURN FANS TO OPERATE RUN CONTINUOUSLY. UPON A LOSS OF CONTROL SIGNAL, THE RETURN FAN VFD CONTROLLER WILL CONTINUE TO RUN FAN AT ITS PRE- SET MINIMUM SPEED. THE CONTROLLER WILL HAVE INDEPENDENT OPERATING MODES FOR EACH FAN TO ALLOW UNIT SHUTDOWN FOR MAINTENANCE. RUN MODE: • EACH RETURN FAN AND ASSOCIATED ISOLATION DAMPER WILL BE STAGED UPON INITIAL START- UP. • THE CONTROLLER WILL COMMAND THE RETURN FAN ISOLATION DAMPER TO OPEN. • AFTER A TIMED DURATION, THE CONTROLLER WILL COMMAND THE RETURN FAN TO RUN. • THE CONTROLLER WILL MONITOR RUN STATUS OF THE VFD AND DISABLE THE FAN IF STATUS IS NOT CONFIRMED. THE ISOLATION DAMPER WILL BE CLOSED WHEN THE CONTROLLER DISABLES THE FAN. • THE ISOLATION DAMPER WILL OPEN UPON A CONTROLLER FAILURE OR LOSS OF 24VAC POWER. • THE CONTROLLER WILL SEND THE SAME CONTROL SIGNAL TO EACH OF THE RETURN FAN VFDS TO MAINTAIN CEILING PLENUM SETPOINT. SMOKE DETECTORS IN FANS: A HARDWIRED SMOKE DETECTOR WILL INTERRUPT THE FAN OPERATION UPON DETECTION OF SMOKE IN THE RETURN DUCT. PRESSURE SENSORS: THE CONTROLLER WILL AVERAGE THE (2) NEW CEILING PRESSURE SENSORS FOR CONTROL. IF THERE I5 A LOSS OF ACCEPTABLE PRESSURE READING, THE CONTROLLER WILL REMOVE THE SENSOR FROM THE CONTROL CALCULATIONS, AND SIGNAL AN ALARM. ALARMS WILL BE PROVIDED AS FOLLOWS: • LOW PRESSURE: IF CEILING PLENUM PRESSURE IS GREATER THAN 0,0IN H• O, RELIEF 1 EXHAUST DAMPER: RUN MODE: THE CONTROLLER WILL MAINTAIN A RETURN DUCT STATIC PRESSURE SETPOINT OF 0.51N H2O (ADJ.) BY MODULATING THE EXHAUST AIR DAMPER (TO THE OUTSIDE), A DUCT STATIC PRESSURE SENSOR IN THE RETURN DUCTWORK DOWNSTREAM OF THE RETURN FANS WILL PROVIDE THE CONTROL SIGNAL. Sabey: SDC5201 -B Page 2 of 2 11 -12 -10 x EXIST SUPPLY AIR ISOLATION DAMPER (TYPICAL) DESIGN FLOW= 155,000 CFM 0 52'F < PA < SPACE TEMP SENSOR 5201 FUTURE 5202 OO 5203 SPACE HUMIDISTAT OW METER MOD- 5201 -2 MOD- 5201 -1 PA > EXISTING SUPPLY AIR/ MANIFOLD M 3 —WAY CONTROL VA 2 TYP EA AHU BY —PASS DMPR 2 TYP EA AHU 2 TYP EACH AHU OSA DMPR, 2 TYP EA AHU — RETURN AIR DMPR 12 —TYP J___ VFD = ur- uF=J- AIR FILTER COOLING COIL AIR FILTER LAIR FILTER ICI f Lv EVAPORATOR EVAPORATOR II 1= II = DUCT STATIC PRESSURE SENSOR EXISTING AHU 52A1 & EXISTING AHU 52A2 4 � SD EXISTING AHU 52B1 _III = ur- ° U z z o 0 c_ AIR FILTER IP/ I+= AIR FILTER VFD EVAPORATOR E pj EVAPORATOR u II = EXISTING AHU 52B1 _III = COOLING COIL AIR FILTER EVAPORATOR E pj u u FUTURE AHU 52C 1 AHU 52C2 RETURN AIR ISOLATION DAMPER (TYPICAL) 5201 7-EXISTING RETURN AIR MANIFOLD FUTURE AHU 52D1 FUTURE 5202 5203 < < MOD- 5201 -9 50,465 CFM PA 41,935 CFM 5,835 CFM TO OFFICE /PRINT RM MOD- 5201 -4 34,070 CFM MOD- 5201 -3 v > SA > 92,400 CFM > PA Y > SA > 32,730 CFM ®— ('—I 1 39,265 CFM W I T 32 1 > PA Y >M> 34,500 CFM 73,765 CFM L- 66,800 CFM SDC 5201A SUITE >M> 159,200 CFM > > VFD -RF- 5201 -C MOD- 5201 -5 1 MOD- 5201 -6 SDC 5201B SUITE RA 73,765 CFM L A 3,035 CFM g FROM OFFICE A 1 DATA CENTER SDC 5201 C SCHEMATIC CONTROL DIAGRAM NOT TO SCALE WORK UNDER THIS PERMIT VFD -RF- 5201 -D G N Ul L 0C 1 MOD- 5201 -7 1 MOD- 5201 -8 j WORK UNDER THIS PERMIT MIOH(b REVIEWED FOR CODE COMPLIANCE Im :0MMM NOV a o 2010 City of Tukwila BUILDING DIVISI(1Iu RECEIVED CITY OF TUKWILA NOV 16 2010 PERMIT CENTER PROJECT: For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503- 331 -0234 SABEY DATA CENTER SDC 52016 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: www.mckinstry.com 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING TONY MARINO BEV PATTERSON BILL DAGGETT 11 -12 -10 SEE DRAWING CONTROL DIAGRAM & SEQUENCE OF OPERATIONS SHEET NUMBER: M0.1 = COOLING COIL AIR FILTER CC o Q CC 0 Q E pj u FUTURE AHU 52D1 FUTURE 5202 5203 < < MOD- 5201 -9 50,465 CFM PA 41,935 CFM 5,835 CFM TO OFFICE /PRINT RM MOD- 5201 -4 34,070 CFM MOD- 5201 -3 v > SA > 92,400 CFM > PA Y > SA > 32,730 CFM ®— ('—I 1 39,265 CFM W I T 32 1 > PA Y >M> 34,500 CFM 73,765 CFM L- 66,800 CFM SDC 5201A SUITE >M> 159,200 CFM > > VFD -RF- 5201 -C MOD- 5201 -5 1 MOD- 5201 -6 SDC 5201B SUITE RA 73,765 CFM L A 3,035 CFM g FROM OFFICE A 1 DATA CENTER SDC 5201 C SCHEMATIC CONTROL DIAGRAM NOT TO SCALE WORK UNDER THIS PERMIT VFD -RF- 5201 -D G N Ul L 0C 1 MOD- 5201 -7 1 MOD- 5201 -8 j WORK UNDER THIS PERMIT MIOH(b REVIEWED FOR CODE COMPLIANCE Im :0MMM NOV a o 2010 City of Tukwila BUILDING DIVISI(1Iu RECEIVED CITY OF TUKWILA NOV 16 2010 PERMIT CENTER PROJECT: For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503- 331 -0234 SABEY DATA CENTER SDC 52016 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: www.mckinstry.com 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING TONY MARINO BEV PATTERSON BILL DAGGETT 11 -12 -10 SEE DRAWING CONTROL DIAGRAM & SEQUENCE OF OPERATIONS SHEET NUMBER: M0.1 SEISMIC BASIS OF DESIGN: BRACE ALL DUCTWORK AND PIPING PER SMACNA'S "SEISMIC RESTRAINT MANUAL" OR MASON INDUSTRIES "SEISMIC RESTRAINT MANUAL" IN ACCORDANCE WITH THE COMPONENT IMPORTANCE FACTOR AND THE SEISMIC HAZARD LEVEL (SHL) OR 'g' LOAD USTED IN THE APPLICABLE TABLE. OBTAIN THE COMPONENT IMPORTANCE FACTOR FROM THE DUCT WORK OR PIPING MATRIX. SEISMIC RESTRAINTS MAY BE EXCLUDED WHEN Ip = 1.0: MECHANICAL AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, AND F WHERE Ip = 1.0 AND FLEXIBLE CONNECTIONS BETWEEN THE COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT ARE PROVIDED AND THAT ARE MOUNTED AT 4 FT (1.22M) OR LESS ABOVE A FLOOR LEVEL AND WEIGH 400 LB (1780 N) OR LESS. [ASCE 7 -02 SECTION 9.6.1 - EXCEPTION 115] MECHANICAL AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, AND F WEIGHING 20 LB (95 N) OR LESS WHERE Ip = 1.0 AND FLEXIBLE CONNECTIONS BETWEEN THE COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT ARE PROVIDED, OR FOR DISTRIBUTION SYSTEMS WEIGHT 5 LB /FT (7N /M) OR LESS. [ASCE 7 -02 SECTION 9.6.1 - EXCEPTION 56] SEISMIC RESTRAINTS ARE NOT REQUIRED FOR HVAC DUCTS WITH Ip = 1.0 IF OMER OF THE FOLLOWING CONDITIONS ARE MET: A. HVAC DUCTS ARE SUSPENDED FROM HANGERS 12 IN. (305 MM) OR LESS IN LENGTH FROM THE TOP OF THE DUCT TO THE SUPPORTING STRUCTURE. THE HANGERS SHALL BE DETAILED TO AVOID SIGNIFICANT BENDING OF THE HANGERS AND THOR ATTACHMENTS. OR B. HVAC DUCTS HAVE A CROSS - SECTIONAL AREA OF LESS THAN 6 FT' (0.557M=). [ASCE 7 -02 SECTION 9.6.3.10] • DUCTILE PIPING IN SEISMIC DESIGN CATEGORIES D, E, OR F DESIGNATED AS HAVING AN Ip = 1.0 AND A NOMINAL PIPE SIZE OF 3 IN. (75 MM) OR LESS. [ASCE 7 -02 SECTION 9.6.3.11.D.3] SEISMIC RESTRAINTS MAY BE EXCLUDED WHEN Ip= 1.0ORIp =1.5: EQUIPMENT ITEMS INSTALLED IN -LINE WITH THE DUCT SYSTEM (E.G. FANS, HEAT EXCHANGERS, AND HUMIDIFIERS) WEIGHING LESS THAN 75 LB (344 N) DO NOT NEED TO BE BRACED INDEPENDENT OF THE DUCT SYSTEM. [INTERPRETED FROM ASCE 7 -02 SECTION 9.6.3.10] UNBRACED PIPING ATTACHED TO IN -UNE EQUIPMENT SHALL BE PROVIDED WITH ADEQUATE FLEXIBILFIY TO ACCOMMODATE DIFFERENTIAL DISPLACEMENTS. [ASCE 7 -02 SECTION 9.6.3.10] PIPING - ROD HANGERS SHALL NOT BE USED AS SEISMIC SUPPORTS UNLESS THE LENGTH OF THE HANGER FROM THE SUPPORTING STRUCTURE IS 12 IN. (305 MM) OR LESS. ROD HANGERS SHALL NOT BE CONSTRUCTED IN A MANNER THAT SUBJECTS THE ROD TO BENDING MOMENTS. [ASCE 7 -02 SECTION 9.6.3.11.4.C] MECHANICAL, PIPING, AND PLUMBING IMPORTANCE FACTOR TABLE COMPONENT DESCRIPTION STANDARD COMPONENT IP =1.0 CRITICAL COMPONENT IP =1.5 NOTES: HVAC - SHEETMETALIEQUIPMENT SHL SHL, with Exp. Anchors HVAC SUPPLY - MEDIUM PRESSURE A X. AA HVAC SUPPLY - LOW PRESSURE Level 2 Ceiling X A HVAC OUTSIDE AIR AA X B HVAC RETURN A .X Level1 HVAC EXHAUST B X A TRANSFER AIR DUCT X GARAGE EXHAUST X GREASE KITCHEN EXHAUST DUCT (TYPE 1 HOOD EXHAUST) X NON - GREASE KITCHEN EXHAUST DUCT (TYPE 2 HOOD EXHAUST) X FLUES - BOILERS, HW HEATERS X PIPING HEATING WATER X CONDENSER WATER X NATURAL GAS X MAKEUP WATER X REFRIGERANT X PLUMBING COLD WATER (POTABLE) X COLD WATER (NON- POTABLE) X HOT WATER (POTABLE) X HOT WATER RECIRC (POTABLE) X CONDENSATE INDIRECT WASTE X NATURAL GAS MEDIUM PRESSURE (2 -5 PSIG) X NATURAL GAS LOW PRESSURE ( <14" WC) X RAINWATER LEADER/ OVERFLOW RAINWATER LEADER X UNDERSLAB DRAINAGE X SANITARY VENT X SANITARY WASTE X SMACNA SEISMIC HAZARD LEVEL DESIGN VALUES: • SEISMIC DESIGN VALUES ARE CALCULATED IN ACCORDANCE WITH IBC 2006. IBC FORCES ARE "STRENGTH DESIGN" BASED. VALUES HAVE BEEN USED TO SELECT FROM SMACNA ADDENDUM NO. 1 TABLE M-10 NEW VALUES IN ORDER TO USE THE SMACNA SEISMIC RESTRAINT MANUAL,. HVAC/SHEETMETAL/EQUIPrV ENT SHL DESIGN VALUES: General Mechanical Equipment - Boiler and furnaces, Other Level Component Ip =1.0 Component Ip =1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Level1 B B A A * 1/2 Brace Spacing Required General Mechanical Equipment - Pressure Vessels on skirts and free standing Level Component Ip =1.0 Component Ip =1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof AA* AA* AA* - NA - Level 2 Ceiling AA M* AA* - NA - Level 1 Ceiling A AA* AA* AA* Levell B AA A AA* * 1/2 Brace Spacing Required HVAC Systems - Vibration Isolated Level Component Ip =1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof AA* AA* AA* - NA - Level 2 Ceiling AA AA* AA* - NA - Level 1 Ceiling A AA* AA* AA* Level 1 B AA A AA* * 1/2 Brace Spacing Required HVAC Systems - Non-vibration Isolated, Mounted in -line with ductwork, Other Level Component Ip =1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Levell B A A A * 1/2 Brace Spacing Required PIPING AND PLUMBING SHL DESIGN VALUES: Piping Systems - High deformability elements and attachments Level Component Ip =1.0 Component 113=1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof B AA A AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Level1 B B A A * 1/2 Brace Spacing Required Highly Deformable Plpe Includes: Steel or Copper Piping with weld /braze /groove fitted joints. Piping Systems - Limlted deformability elements and attachments Level Component Ip =1.0 Component Ip =1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Levell B B A A * 1/2 Brace Spacing Required Limited Deformable Pipe Includes: PVC or PVDF Piping Piping Systems - Low deformability elements and attachments Level Component 113=1.0 Component 1p1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof AA AA AA* AA* Level 2 Ceiling A A AA AA Level 1 Ceiling A A A A Level1 B B A A * 1/2 Brace Spacing Required Low Deformability Piping Includes: Cast Iron, Glass Pipe, FRP (Fiberglass Reinforced Pipe) SEISrV IC ALLOWABLE STRESS DESIGN VALUES: • SEISMIC DESIGN VALUES ARE CALCULATED IN ACCORDANCE WITH IBC 2006. IBC FORCES ARE "STRENGTH DESIGN" BASED. VALUES HAVE BEEN CONVERTED TO "ALLOWABLE STRESS DESIGN" VALUES IN ORDER TO UTIUZE MASON INDUSTRIES SEISMIC RESTRAINT GUIDELINES. •• THESE VALUES CAN BE USED TO SELECT SEISMIC BRACING FROM MASON INDUSTRIES SEISMIC RESTRAINT GUIDELINES. HVAC/SHEETV ETAL/EQUIP SEISMIC 'g' LOAD: General Mechanical Equipment - Boiler and furnaces, Other (Converted to ASD) Level Component Ip =1.0 Component Ip =1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g General Mechanical Equipment - Pressure Vessels and skirts free standing (Converted to ASD) Level Component 113=1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .91 g 1.21 g 1.36 g 1.82 g Level 2 Ceiling .65 g 1.09 g .98 g 1.63 g Level 1 Ceiling .48 g .8 g .72 g 12 g Level 1 .3 g .5 g .45 g .76 g V ENT HVAC Systems - Vibration Isolated (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .91 g 1.21 g 1.36 g 1.82 g Level 2 Ceiling .65 g 1.09 g .98 g 1.63 g Level 1 Ceiling .48 g .8 g .72 g 1.2 g Level 1 .3 g .5 g .45 g .76 g HVAC Systems - Non - vibration Isolated, Mounted In -line with ductwork, Other (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g PIPING AND PLUNGING SEISMIC 'g' LOAD: Piping Systems - High deformability elements and attachments (Converted to ASD) • Level Component Ip =1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .26 g .61 g .39 g .91 g Level 2 Ceiling .23 g .44 g .34 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g 34 g .34 g Highly Deformable Pipe Inc udes: Steel or Copper Piping with weld /braze /groove fitted joints. Piping Systems - Limited deformability elements and attachments (Converted to ASD) Level Component Ip =1.0 Component Ip =1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g Limited Deformable Pipe Includes: PVC or PVDF Piping Piping Systems - Low deformability elements and attachments (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .61 g .61 g .91 g .91 g Level 2 Ceiling .44 g .44 g .65 g .65 g Level 1 Ceiling .32 g .32 g .48 g .48 g Level 1 .23 g .23 g .34 g .34 g Low Deformability Piping Includes: Cast Iron, Glass Pipe, FRP (Fiberglass Reinforced Pipe) REVIEWED FOR CODE COMPLIANCE AcorionVED NOV 3 0 2010 City of Tukwila BUILDING DIVIRION M10-1 � RECEIVED CITY OF TULA NOV 16 2010 PERMIT CENTER PROJECT: instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com SABEY DATA CENTER SDC 5201B 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING TONY MARINO BEV PATTERSON BILL DAGGETT 11 -12 -10 SEE DRAWING SHEET TITLE: SEISMIC INFORMATION SHEET NUMBER: M0.2 f, 2; B U)) L I SCOPE OF WORK THIS PERMIT APIUCATION i I I ,� �_j _ -. _ -_- -- . a-_�_ J J i t p) R A- '1 r fill 3- I gra I I rv7 LA t� f] ice) X („ ) 1 k 2ND FLOOR HVAC PLAN ;N) M2.2 SCALE: 1/32" = 1' -0" 'P 0) CD ) � J) ( 2`1 ■ f3) :1) iii 14' J tO-ft.10 REVIEWED FOR — CODE COMPLIANCE APPlonVFD NUV 3 0 2010 City of Tukwila BUILDING niminN City of Tukwila BUILDING niminN RECEIVED CITY OF TUKIMLA NOV 16 2010 PERMIT CENTER PROJECT: instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com SABEY DATA CENTER SDC 5201B 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: ENGINEERING DESIGNED BY: TONY MARINO DRAWN BY: BEV PATTERSON CHECKED BY: BILL DAGGETT JOB NUMBER: DATE: 11 -12 -10 SCALE: SEE DRAWING SHEET TITLE: 2ND FLOOR HVAC PLAN SHEET NUMBER: M2.2 T 1 (E)68x60(TYP) (E)RF- 5202 -A 36x50 E)MOD- 5202 -12, (E)RF- 5202 -B 68x60 (E)150x72 l 1 WO [(E)RF- 5201 -B [(E)RF- 5201 -A / --(RF- 5201 —D) (E)68x60 (E)68x60 II / I(E)68x60 y (E)VFD A(r'P)- —V> N(E)25'WX6'H EXHAUST LOUVER MOD- 5202 11 _ (ERF- 5202 -C 68x60 (E)68x60 (E)68x60 (E)68x60 Fl 216Lx90Wx72H ( E)MOD- 5202 -10 (E)RF- 5202 -D Second Line DATA CENTER PROVIDE 5 TEMPERATURE SENSO AND 5 HUMIDITY SENSORS WHET DIRECTED BY OWNER (E)MOD- 5202 -9 (E)170x60 Line ENTER LOCK FIRE DAMPER OPEN (E)16'x8' SUPPLY OPENING TO BE LO A1ED NEAR HEAT --PRODUCTINIDF EQUIPMENT- (E)170x60 REMOVE 150 SF MINIMUM OF WALL ABOVE PLENUM fine } i i\ fi I Vf E (E)TE SENS UMID YP) (E)192x60 �- ( E)MOD- 5202 -6 (E)52x52 APPROX 650 FPM THROUGH FREE AREA OF SUPPLY OPENING- E)48x40 (E)SCOOP (E)100x48 (E)60x30 M 0 0 O 0 . 0 O o O ,:, do O 0 o() "o (E)MOD-5202-2 (E)70x76 (E)60x40 (E) 228x84 52500 CFM 0 0 0 0 0 APPROX 650 FPM THROUGH FREE AREA OF SUPPLY OPENING 92,200 CFM I SUPPLY AIR }(( E)MOD- 5202 -1 Second Line DATA CENTER (E)VAV- 5201 -1 -\ (E)136x60 AUVA M (E)96x48 VCD -43 FAST ACTING MOD; r s l (E)EC 24X48 1 4-! 1 DUCTWORK DEPRESSIONS TO ALLOW FOR AIRFLOW ABOVE CHIMNEYS (E)100x60 LOUVER 0— 1 (E)EXHAUST AIR LOUVER MIN 3.5 SQ FT FREE AREA (48Wx24H) - (E)48x12 1;0 econd, ne (E)150x60 _ (E)ACU= 5201 -1 B (E)ACU- 5201 -1 A r ■ 1- Second .ine C_ (E)28x14 (E)140 (E Rf JT • 14� . 1� 25 \Mb. xe 1&)22x i (E)EC1 12 -3 (E)66x60 econd Lire RICE (E)140 -52011/1 I --(E)VFD V- ABOVE I-EF- 5201 -1 CEILING rd- tip— CENTER )50x70 STORAGE iv BUILD Root 2.56 ' (E)DT12— .,.. J�. _.._.._ (E)FIRE RATED SOFFIT FOR FIRE DAMPER PROVIDED BY GC K CFM 5d& ;.FPM UP I (E)DID -3 126x90 126x910 TQ 3RD MC'H OR MAKF I 2NDLFL00 11111. 1 WHEN ABOVE f Sf 1 " "WC O E ELO WC MOD OPENS! TO SSURE AND ALAM IS -rr: ; ni it LI 'E SE iT 2ND FLOOR ENLARGED HVAC PLAN l M3.2 SCALE : 1/8" 1' -0 0 4' 8' 16' MEM REVIEWED FOR CODE COMPLIANCE poonvEf NUV 3 0 2010 City of Tukwila BUILDING DIVI'RIniv CITY OF TUKWILA NOV 1 b 2010 PERMIT CENTER PROJECT: rnstry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503 - 331 -0234 SABEY DATA CENTER SDC 5201B 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: www.mckinstry.com 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: ENGINEERING DESIGNED BY: TONY MARINO DRAWN BY: BEV PATTERSON CHECKED BY: BILL DAGGETT JOB NUMBER: DATE: 11 -12 -10 SCALE: SEE DRAWING SHEET TITLE: 2ND FLOOR ENLARGED HVAC PLAN SHEET NUMBER: M3.2 DUCT CONNECTIONS PER MANUFACTURERS INSTALLATION INSTRUCTIONS (TYP) --\ DUCT ED OPENING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS AND UL555 BY GENERAL CONTRACTOR WALL RETAINING ANGLE PROVIDE ONE ACCESS DOOR FOR ACCESS TO FIRE DAMPER @COMPLY WITH UL555 AND MANUFACTURER'S INSTALLATION INSTRUCTIONS WALL SLEEVE 1 FIRE DAMPER TYPE B M4.0 NOT TO SCALE . . . r' °- iv• ' °-•Ir▪ '° •Ir = °- r'° I,•° 1'ir�:;!: ' °-•'r + °-•• /r' °- . r•° •I V•'° • •Ir=°- •;,°.,• °- I••°- Ir•° -•Ir'° •�v�w°- ••1I,•°- ,q•° •,v°- •IV'=° -•fir •vii Ij• °.. 41 •,,_° •° v - .. a,° .v _ .. S •,j ▪ ••v ° e_�r Ea r- U bolt rod to stru bolt rod to strut 2x2xrI angle 1 0 45 Longitudinal 1 0 45 Transverse Superstrut A -12 Channel Superstrut A -12 Channel 1/7' threaded �— Superstrut A -12 Channel 25' -0" Maximun Spacing. TYPICAL DUCT SEISMIC RESTRAINT 2x2xat ang 1 0 45 Longitudinal 1 0 45 Transverse /1 lhreoded Rod NOT TO SCALE MASON INDUSTRIES, Inc. Manufacturers of Vlbrptkn Control Products 360 Rabro Drive 2101 W. descent St., Suite D Hauppauge, NY 117E5 Anaheim, CA 92801 1:411/348-02B2 714 2727 • ••• FAX 16/348 -0279 FAX 7 4 538 -5738 TELEX 99 -5464 . CERTIFIED FOR JOB NAME: SABEY CUSTOMER: HOSKINS CUSTOMER P.O.:_________ JOB NO.: MASON E.Q.: 23880 DWG. NO.: WF- 23860 -01. REQUIRED: (21 TAO: RF 52B TYPE 301 Hanger SCB(SCBH � SUPPORT STRUCTURE r •� r Ili ( 1 ) 5/811 DIAMETER A307 STEEL BOLT - (PER BRACING LOCATION) . UNIT: GREENHECK VADS- 30F14- 14-A7.5 WEIGHT: 850 LBS ELEVATION SCB•2 REF. X1 RW3ON -B -338 REF. WF 23680-4 UC-1 (OPA -0349) @ 39" MAX. SPACING REF. X5A ROD STIFFENER STRUT (IF ROD EXCEEDS 21'1 5/8" THREADED ROD SCBH -2 REF. X2 3/16 °.DIAMETER ' STEEL AIRCRAFT CABLE, 7 X 19 STRAND CORE DWG. NO. WF- 23880-01 _ _ __ __ _ _ __ • __ _ _ _ _ _. • _ r • iv •••.- I�.r -= •,r• 1�' ;v' • 1v, • • •• :r• Iv' • Iv= • • 1 1,�.,° /r • 1 ,•Ir° �r • /r°- 1= • Ii it • • •` •ti- s • i i i% • • • "� • • • it 0 , • .�- • v mot' -:-�, v v v•. v ►• ►•, v • • v v • ,• • v v • Threaded Rod-7 T AZ. Superstrut A -12 Channel 7' -6" Maximun Spacing TYPICAL DUCT HANGER DETAIL T Threaded Rod REVIEWED FOR „ CODE COMPLIANCE APDPNIVED NUV 3 0 2010 City of Tukwila BUILDING nIVISIfIN NOT TO SCALE M(Oi� CITY OF TUKWILA NOV 16 2010 PERMIT CENTER PROJECT: For Th instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503 - 331 -0234 SABEY DATA CENTER SDC 5201B 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: www.mckinstry.com 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING TONY MARINO BEV PATTERSON BILL DAGGETT 11 -12 -10 SEE DRAWING SHEET TITLE: HVAC SECTIONS & DETAILS SHEET NUMBER: M4.0 DUCTWORK SPECIFICATION DUCT SYSTEM OR SECTION SMACNA PRESSURE & SEAL CLASSES DIMENSIONS (INSIDE, OVERALL) MATERIALS (DUCT, LINING) FITTINGS (SHOP BUILT) PURCHASED FITTINGS (DAMPERS, LOUVERS) INSULATION (INDOOR, OUTDOOR) SEISMIC (BESIDES NORMAL HANGERS) TESTING REQUIREMENTS (FIELD TESTING) HVAC SUPPLY MEDIUM PRESSURE (FROM AHUs) SMACNA +2" PRESSURE, SEAL CLASS A INSIDE CLEAR DIMENSIONS SHOWN. OVERALL, ALLOW 4" ADD'L FOR FLANGES ON RECTANGULAR. UNLINED GALVANIZED DUCT, SEE SUBMITTAL FOR GAUGE AND REINFORCEMENT. RECTANGULAR TO HAVE TDF CONNECTIONS, ROUND MAY BE SPIRAL FLEX: 4" MAX LENGTH, THERMAFLEX GKM OR EQUAL SQUARE CORNER W/ INSERTS OR 5 —GORE ELBOWS, CENTERUNE RADIUS OF 1.5e CONICAL TEES FOR BIDIRECTIONAL FLOW. 1 -1/2 HR FIRE DAMPERS PER UL555S 110V N.C. OPERATOR OUTSIDE DUCT INDOOR: R -3.3 RIGID ATTACHEMENT TO STRUCTURE NONE REQUIRED HVAC RETURN /EXHAUST MEDUIM PRESSURE (INLET TO AHUs /FANS) SMACNA +2' PRESSURE, SEAL CLASS A INSIDE CLEAR DIMENSIONS SHOWN, ALSO OD FOR ROUND. OVERALL, ALLOW 4" ADD'L FOR FLANGES ON RECTANGULAR. GALVANIZED DUCT, 1" LINING ONLY WHERE INDICATED ON PLANS. SEE SUBMITTAL FOR GAUGE AND REINFORCEMENT. RECTANGULAR TO HAVE TDF CONNECTIONS, ROUND MAY BE SPIRAL SQUARE CORNER W/ INSERTS OR 5 —GORE ELBOWS, CENTERUNE RADIUS OF 1.5e CONICAL TEES FOR BIDIRECTIONAL FLOW. 1 -1/2 HR FIRE DAMPERS PER UL555S 110V N.C. OPERATOR OUTSIDE DUCT INDOOR: R -3.3 RIGID ATTACHEMENT TO STRUCTURE NONE REQUIRED NOTES: 1. PROVIDE 3 FEET MINIMUM OF FLEX DUCT WHEREVER FLEX DUCT IS USED TO CONNECT A DIFFUSER TO THE DUCTWORK. 2. IF THESE PLANS CONFLICT WITH ARCHITECTURAL PLANS FOR DIFFUSER PLACEMENT, USED THE ARCHITECT'S PLACEMENT IF SPACE ALLOWS. 3. FIBERGLASS DUCT UNER IS NOT TO BE USED. 4. PROVIDE AND COORDINATE ALL ACCESS DOORS NECESSARY TO MAINTAIN, ADJUST AND TEST HVAC COMPONENTS ABOVE THE CEILING. RETURN FANS TAG # RF- 5201 -A, RF- 5201 -B, RF- 5201 -C (EXISTING) RF- 5201 -D QUANTITY 3 1 BASIS OF DESIGN MANUF. GREENHECK GREENHECK MODEL VADS- 54H21- 27 -B50 VADS- 54H21- 27 -B50 LOCATION 2ND FLOOR ROOM 5203 2ND FLOOR ROOM 5203 SERVICE VAV RETURN AIR VAV RETURN AIR FAN TYPE DIRECT DRIVE MIXED FLOW DIRECT DRIVE MIXED FLOW AIRFLOW 77,500 CFM 77,500 CFM . STATIC PRESSURE 2" 2" BHP 46.84 HP 46.84 HP MOTOR HP 50 HP 50 HP VOLTAGE/PHASE 480V/30 480V/3d MOTOR EFFICIENCY 87.5% OR BETTER 87.5% OR BETTER MOTOR RPM 1770 1770 VFD BY MECHANICAL BY MECHANICAL TWO SPEED MOTOR NO NO MOTOR ENCLOSURE TEFC TEFC ADJUSTABLE PITCH/FIXED PITCH SHEAVE NEITHER, VFD FOR ADJ. NEITHER, VFD FOR ADJ. OVERALL HEIGHT 59" 59" OVERALL WIDTH 59" 59" OVERALL LENGTH (ACCESS SECTION NOT INCLUDED) 69" 69" MOUNTING TYPE SUSPENDED SUSPENDED MOUNTING POSITION HORIZONTAL HORIZONTAL TOTAL WEIGHT (LESS ANY ACCESSORIES) 1800 LBS 1800 LBS BASE NA NA ISOLATOR NA NA THRUST RESTRAINT NA NA FLEX CONNECTOR YES YES MOTION RESTRAINT NOT REQUIRED NOT REQUIRED SMOKE DETECTOR NOT REQUIRED NOT REQUIRED DISCONNECTS BY ELEC. BY ELEC. STARTER (BY ELEC) NR NR VFD CONTROL (McK PROVIDE, ELEC INSTALL) YES YES ELECTRONIC 0 & M DATA YES YES 110 V. SERVICE OUTLET WITHIN 25' BY ELEC. BY ELEC. OPTIONS / ACCESSORIES SPECIAL COATINGS NA NA OSHA APPROVED MOTOR COVER NA NA BELT GUARD NA NA INSPECTION SECTION W/ BOLTED ACCESS DOOR NA NA WIND SHROUD NA NA SPARK RESISTANT NA NA MOTORIZED DAMPER PER SEC 1412.4.1 NA NA SONES NOISE CRITERIA LwA dBA - SOUND - POWER -BY- OCTAVE BAND INLET INLET 63 107 107 125 108 108 250 105 105 500 101 101 1000 100 100 2000 101 101 4000 • 96 96 8000 96 96 instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 16970 NE MASON ST SUITE 100 PORTLAND, OR 97230 503 - 331 -0234 www.mckinstry.com PROJECT: SABEY DATA CENTER SDC 5201B 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: 11/12/2010 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: ENGINEERING DESIGNED BY: TONY MARINO DRAWN BY: BEV PATTERSON CHECKED BY: BILL DAGGETT JOB NUMBER: -- �� DATE: 11 -12 -10 REVIEWED FOR SCALE: SEE DRAWING CODE COMPLIANCE a.IOD AVED NUV 3 0 2010 City of Tukwila BUILDINGDIVRI(1M tittOik) CITY OF TUKWILA NOV 16 2010 PERMIT CENTER SHEET TITLE: HVAC SCHEDULES SHEET NUMBER: M7.0