Loading...
HomeMy WebLinkAboutPermit M10-162 - MIZUKI JAPANESE BUFFETMIZUKI JAPANESE BUFFET 17950 SOUTHCENTER PY M10 -162 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: htlp: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 3523049123 Address: 17950 SOUTHCENTER PY TUKW Project Name: MIZUKI JAPANESE BUFFET Permit Number: M10 -162 Issue Date: 12/13/2010 Permit Expires On: 06/11/2011 Owner: Name: MADISON INVESTMENTS LLC Address: P O BOX 1922 , BOZEMAN MT 59771 Contact Person: Name: KING LEE Address: PO BOX 80563 , SEATTLE WA 98108 Email: KING @MONARCHTRADINGCORP.COM Contractor: Name: MONARCH TRADING CORP Address: PO BOX 80563 , SEATTLE WA 98108 Contractor License No: MONARTC065Q 1 Phone: 206 - 396 -3173 Phone: 206 -763 -6161 Expiration Date: 03/06/2011 DESCRIPTION OF WORK: INSTALL (5) TYPE I KITCHEN RANGE HOODS AND (2) TYPE II VAPOR HOODS FOR DISHWASHING PER PLAN Value of Mechanical: $43,000.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $710.31 International Mechanical Code Edition: 2009 Date: U--` ( 3` V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: V I nJ(,) Lt-G/ Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -162 Printed: 12 -13 -2010 • • PERMIT CONDITIONS Permit No. M10- 162 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 15: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 16: U.L. central station supervision is required. (City Ordinance #2050) 17: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 18: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) doc: IMC -4110 M10 -162 Printed: 12 -13 -2010 19: Portable fire extinguishers, not sed in cabinets, shall be installed on the h or brackets supplied. Hangers or brackets shall be securely anchore he mounting surface in accordance with th ufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M10 -162 Printed: 12 -13 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. Isitto-tcp2-„ Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: p 4 5 Tenant Name: Property Owners Name Mailing Address: r27 13-1'1 King Co Assessor's Tax No.: 4A ft; Suite Number: New Tenant: LL /e34 City 52- 3u (f y /L3 Floor: ❑ Yes ❑..No /147 State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: h _ Mailing Address: D V eO7C , Q 0 E -Mail Address: K ('�' £ 1 t7V) a rc �j �ra c i i.t5 J �� MECHANICAL CONTRACTOR INFORMATION Day Telephone: City Fax Number: State Zip Company Name: Mailing Address: Contact Person: E -Mail Address: K l ®_G%1er)'atrCL)tk (4) a it M 0 n G-V UL [ i t - e , ( A ) Co, (f- S S - ) d -rs / Si- k( C a City Day Telephone: / n P • �l Fax Number: Contractor Registration Number: � V N,/ l G obc cx' ( /mil- `e 0.6k ( )'°Gj`7636//1 1: bC6 Expiration Date: 1z01( ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: hove_ r(,4 /jam ti Mailing Address: State City Contact Person: Day Telephone: Fax Number: E -Mail Address: Zip ENGINEER OF RECORD - -All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: i O3-Se` Day Telephone: • E -Mail Address: Fax Number: re ote,l.,s I Oho ss_e-Q G t 1-315"4 Sts' .-)cur/n J; H:\Applications\Forms- Applications On Line \2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh State Zip Ai -574y) Page 1 of 2 Valuation of Project (contractor's bid price): $ T 3,00 Scope of Work (please provide providedetailed information): "1,,,dt5f ,J T11 N,'cf1 R44 e ( 1/4/16 27 LA j% Ia U ) f / Use: Residential: New Commercial: New 0 Replacement Replacement ❑ Fuel Type: Electric ❑ Gas EJ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: yp . Qty. Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent J Hood and Duct .�. ` Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 1S.-7� t i-1 G' Mailing Address: Print Name: Date: ( { ?/C t Day Telephone: (Z''r, �, i t`117 J a {-1C v /` 1( \ }'r) J State Zip City Date Application Accepted: _ I Date Application Expires: �_ �' Staff Initials: i It . // H:WpplicationsWorms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049123 Permit Number: M10 -162 Address: 17950 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 11/18/2010 Applicant: MIZUKI JAPANESE BUFFET Issue Date: Receipt No.: R10 -02486 Initials: WER User ID: 1655 Payment Amount: $568.25 Payment Date: 12/13/2010 01:55 PM Balance: $0.00 Payee: MONARCH TRADING CORPORATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 059341 568.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 568.25 Total: $568.25 doc: Receiot -06 Printed: 12 -13 -2010 i • 4I�4 wq� City of Tukwila C 190a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 3523049123 Permit Number: M10 -162 Address: 17950 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/18/2010 Applicant: MIZUKI JAPANESE BUFFET Issue Date: Receipt No.: R10 -02345 Initials: User ID: Payee: WER 1655 Payment Amount: $142.06 Payment Date: 11/18/2010 11:43 AM Balance: $568.25 MONARCH TRADING CORPORATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 059259 142.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 142.06 Total: $142.06 doc: Receiot -06 Printed: 11 -18 -2010 INSPECTION RECORD Retain a copy with permit IN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 M14 -1(612= Project; , 2,ti ` &J1 Type i ke - +- . ,/U ii___-' Address: �, 143 953 Sc_ioAfrcl Date Called: Special Instructions: VvTST PA4 f C JAi tell er o —Pho7_53-3 Date Wanted: �-(� ��� (' _ a.m p.m. Requester: 15 - / 3 Approved per applicable codes. a Corrections required prior to approval. COMMENTS: 94 7-; /c.")-Avi Inspector: Dater 2 C f n REIN ECTION FEE REQ, AIRED. Prior to next inspection. fee must be paid at 6300 Southcenter lvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Alto 7,4 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Prailq: Type ofAlnspectio : i`i pP T 4 ,) As � /men t As ifiii tat Address: 1 `AS o Sc . pin-►(G,J / Date Called: ) Nine Pc A. /1- . "1"-sr: Al FAy PA-m-L--- �-... Special Instructions: Date Wanted: >,� !� 2 — .m.. m. Requester: — 1 Phone No: ' Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4 -F •ta 6Jgiv60.i i`i pP T 4 ,) As � /men t As ifiii tat hr sMal�e. s(„J`r 6JiJA vi ) Nine Pc A. /1- . "1"-sr: Al FAy PA-m-L--- e .er (--D r ■ A.Sp e r r: J /t O.% f .1 1, Ho( m e. , -r A4 r t J 4--a so LS' tT `ice rece:v;,• 3 -e�7" s, c.c. )br r,!.'4.- — 1 Inspegtor: Date 2� ( 1 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD�� Retain a copy with permit INSPE(tION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 7Y7.72 2/1 Type of In pectio33 ./5' `� o1 - /7"//4/e", 1 �--. Address: Date Called: ) sh ee / < /A /6/6 ' 7r..c.%'t/ GAS .S ; ?/' ,�. / ci,=-/p.044,/?/7 / 4/# A/ 9 !D� Bn/ P R.4- s 7 Special Instructions: Date Wanted: G. r // m. Requester: Phone No: Approved per applicablgcodes. Corrections required prior to approval. COMMENTS: o1 - /7"//4/e", ) sh ee / < /A /6/6 ' 7r..c.%'t/ GAS .S ; ?/' ,�. / ci,=-/p.044,/?/7 / 4/# A/ 9 !D� Bn/ P R.4- s 7 /4 00 At *-4-9 1 : / nspectc�: tf/'r4A9 'at SPECTION E REQUI Date: � ED. Pri to next inspection. fee must be .aid at 6300 Southcenter Bl d.. Su' a 100. Call to schedule reinspection. • 3 G INSPECTION RECORD Retain a copy with permit _ / - INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING .DIVISION IA* 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 01 /,tea /.r 2- Type of Inspection: 1.2 lh - /Al Address: /740a S t1*•vii-rr/. p Date Called: Special Instructions: 1t Date Wanted: r. — Z-• "+ri p.m. Requester: - l�0 J-t 1/1 Phone No: o 4.0.3g6 —0417 u.. , 1 _.- A ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: t6..�..1 1t Pi.." s' •_r7- l�0 J-t 1/1 94---f .A.: 1 S ,) 4 u.. , 1 _.- A e ,14:.J J) S J ,/f ,440....i.. e) .` ., 4"',a.1 S ".f, ter.. . mil- 1 • 4(' Jtri r_, Of _ i A a b .)'r - :')A 'y -.) 1 P it4 Ai . J.' :1-,it. .4- ...-4, a 14 e-Ti 0 -.K. . , , \ .i ... (Inspec: 3 -If ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. + ., ,,,•.. 4 INSPECTION RECORD Retain a copy with permit, Lt _ %6Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R— 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: /11/ at/ Z" c ZriAs3,vE Type of Inspection: dO 0/6//—.1-4,/ Addressl ' Date Called: Special Instructions: Date Wanted: cs2 — 7 - »`»'. p.m. Requester: . Phone No: d 6- 4 - ethe3 / 7 ,IjApproved per applicable•codes. • • Corrections required prioY to approval. COMMENTS: • . s 0 ❑ REINSPECTION FEE REQUIRED. Prior to next.inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT Nth CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIyd., #100, Tukwila. WA 98188 Permit Inspection R quest Line (206) 431 -2451 (206) 431 -3670 Project: /'Y,/2 2WI _ t- )4Prn%l�S,f Type of Inspection: ).a t- -A_.� i , t Address: ate Sa11e(^d `tiA 6 6 6vp 8 d4 Special Instructi s: Date Wanted: l Requester: Phone No: Sri 10 .. • • • Approved per applicable codes.. Corrections required pr 4t to approval. COMMENTS: p / t ` /, �j' A i �+ eci J" �- 1 r y " LA :_t&T pi,t_ 23 A DA e.„9 1,--4 jr-fer- q_. P' _ 4 ti 6 t Sd( Asr cd 4 , _ 6, l"' k1X (Q - I )s( stoker Al d t.� r e d tAir't4 AA1 o1J O.L r pro r + - CP 4.r f 3 1,\X A r` igfx<zr �.i- , , A, ,, 11 (re f. 616, / n (1-3 /" _, rJ ie s,r ( t."4,11) 4 t r; 13 r 7. (k 0 ri REINSPECTION FEE REQUIM '6.`'rior to next inspection.•fee must be .: paid at 6300 Southcenter !Ilya Suite 100: Call to schedule reinspection. • • L�� INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit + +.��. pi ,'4 �• M PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: - < , Type of/Inspection: ' Address: / ; q.r-o Suite #: `; C . J =,-.- lr' Contact Person: •' Special Instructions: f. i f 1, C., ht-lNj °.- f/il A C D u c.--f J eji eGo � it. c .. -7"7i r, ' Phone No.: Approved per applicable codes. \Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: f. i f 1, C., ht-lNj °.- f/il A C D u c.--f J eji eGo � it. c .. -7"7i r, ' ,f } r,,nr;. L, - -e rJ (Pr) ' i... .c.' i }f_4 c ;r.:7v_.g r.�+tA z,-- ift�G�zf •- o /, .' ✓ :A r s Su % «, ��, c I ;,K1..1J 1.,-_,,. r' S A �+ 11 1 1 (' l r f j ( 1 P-. l -.c- :-. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: , Date: tfr ,f5',; , l Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete M a s o n r y A s p h a l t R o o f i n g P i l i n g S t e e I S o i l s W o o d April 29, 2011 File: 11 -105 AV 02 2011 Vito Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit No.: Mizuki Buffet thcenter Pkwy. A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspections were required and copies of those reports have already been sent. 1. On site.welding .. To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President cc: Monarch Trading Corporation -King Lee Roddy Nolten P.E. Tel: (425) 881 -5812 Fax: (425) 881 -5441 • 7126 180th Ave. NE • P.O. Box 2523 * Redmond, WA 98073 RECEIVED FEB 07 20111 COMMUNITY DEVELOPMENT Field Report Report #: 52201 A.A.R. Testing Laboratory, Inc. 7126 180th Ave.N.E., Park 180, Suite C101, Redmond, WA 98052 Phone 425.881.5812 Fax 425.881.5441 Client: Monarch Trading Corp. P.O. Box 80563 Seattle, WA 98101 Contact: King Lee Project Number: Permit #: Project Name: Address: 11 -105 M10 -162 Mizuki Buffet 17950 Southcenter Pkwy. Inspection Performed: Welding Date: 1/12/2011 Time: Temperature: On site for the following: 1) Inspected welds for five (5) duct runs for five (5) fan hoods. All work completed per minimum AWS D1.3 requirements. Distribution: V Distribute Client Distribute Engineer Distribute Municipality Distribute Architect Distribute Contractor Distribute Owner Distribute Other Distribute Other Inspector: Blisserd, Jonathan (JD) Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden CJR Engineering Civil - Structural Engineering Comprehensive Project Management 3814 231st Avenue SE Phone: (425) 269 -5204 Sammamish, WA 98075 -9212 Fax: (425) 671 -0003 REVIEWED FOR CODE COMPLIANCE APIPMVED DEC 1 u Zu iU City of Tukwila BUILDING DIVIRInMM JOB NO. 030712 SEISMIC BRACING REPORT PREPARED FOR: MIZUKI JAPANESE BUFFET 17950 SOUTHCENTER PKWY TUKWILA, WASHINGTON JULY 12, 2010 I 62 RECEIVED NOV 18 2010 © Copyright 2010 by CJR Engineering PERMIT CENTER 4.166" HOOD ,EXISTING ROOF TRUSSES SPACED 48" O.C. MAKE UP ----- AIR a / 1/2" THREADED ROD (TYP) - -- -_ _ -_ _ UNISTRUT P -1000 CHANNEL ____ D FROM TRUSSES / r 1 \ G EXISTING WALL EXISTING TRUSS x UNISTRUT P10C 0 CHANNEL EXISTING -- WALL /A. 2 -1/4" UNISTRUT P -1000 DIAGONAL BRACES PER DETAIL BELOW TYP HOOD PLAN VIEW N.T.S. UNISTRUT P1000 CHANNEL (TYP) — UNISTRUT P1000� CHANNEL UNISTRUT L5410 -037 HOOD UNISTRUT P1000 BRACE AT FRONT OF HOOr) ONLY A SECTION ,1/2" THREADED / RON `SUSPENDED CEILING HOOD 1 DIMENSIONS 14' WIDE X 4' DEEP X 2' TALL N.T.S. CJR Engineering 3814 231st Avenue SE Sammamish, WA 98075 Ph: (425) 269 -5204 Fx: (425) 671 -0003 email: info @cjreng.com PROJECT: MIZUKI BUFFET 17950 SOUTHCENTER PKWY TUKWILA, WA SHEET 1 OF 2 EXISTING TRUSSES EXISTING WALL ` HOOD 16 -GA Z CHANNEL EA. STUD, ATTACH PER DETAIL BY OTHERS UNISTRUT P1000 CHANNEL SUSPENDED FROM TRUSSES SECTION N.T.S. BOTTOM CHORD STEEL ANGLE ----- UNISTRUT L5410 -037 ANGLE CLIP - -- - ATTACH TO UNISTRUT WITH 1/2" x 15/16" HEX HEAD CAP SCREWS AND 1/2" NUTS UNISTRUT P1000 BRACE 1/2" THREADED ROD (TYP) /BOTTOM CHORD OF / TRUSS UNISTRUT P1000 CHANNEL SUSPENDED FROM TRUSSES \1/2" THREADED RON \WASHER AND NUT CJR Engineering 3814 231st Avenue SE Sammamish, WA 98075 Ph: (425) 269 -5204 Fx: (425) 671 -0003 email: info @cjreng.com PROJECT: MIZUKI BUFFET 17950 SOUTHCENTER PKWY TUKWILA, WA SHEET 2 OF 2 CJR Engineering Job No. '030712 Prepared for King T. Lee Seismic Analysis: Ss Fa Sms Sds 1.00 1.10 1.10 0.73 S1 Fv Sms Sds 0.40 1.60 0.64 0.43 Rp Ip z h ap (ft) (ft) 2.50 1.00 10.00 10.00 1.00 Seismic Force: Item Wp Fp1 Fp2 Fp3 Governs (K) Upper Lim Lower Lim (K) (K) (K) (K) Hood 0.90 0.32 1.06 0.2 0.32 Fan 2 0.34 0.12 0.39 0.07 0.12 Fan 1 0.48 0.17 0.56 0.1 0.17 Equipment Dimensions Item H Width L Lc (ft) (ft) (ft) (ft) Hood 2.00 2.50 11.00 9.00 Fan 2 2.00 1.00 1.00 Fan 1 2.00 1.00 1.00 Item Overturning and Stabilizing Moments: OTM Vertical Gravity Total Component Load Vertical (ft -K) ( #) ( #) ( #) Hood 0.32 1,015.88 225.75 1,241.63 Fan 2 0.12 151.20 84 235.20 Fan 1 0.17 214.20 119 333.20 Equipment Bracing for Wizuki Restaurant, Tukwila CJR Engineerina Job No. (030712 Item Prepared for King T. Lee Lateral Diagonal Brace Length Capacity Stress Load Load ratio ( #) ( #) (ft) ( #) Hood 317.86 448.18 P1000 2.82 3800 0.12 Item Connector Hood LS410 -037 Fan 2 Fan to curb #10 self tapping metal screws spaced 6" o.c. Curb to framing SDS1 /4x3" lag screws Fan 1 Fan to curb #10 self tapping metal screws spaced 6" o.c. Curb to framing SDS1 /4x3" lag screws Fan #2 Item Weight ( #) Fan #2 281 Curb 25 Ducts 30 Total 336 Fan #1 Item Weight ( #) Fan #1 170 Curb 20 Ducts 217 Fire Wrap 60 Conduits 9 Total 476 Hood Information Hood Length Weight No. (ft) (K) 1 11 0.903 2 11 0.887 3 11 0.903 4 16 0.728 5 12 0.774 6 3 0.113 7 5 0.143 Equipment Bracing for IMizuki Restaurant, Tukwila • • PERINI COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -162 DATE: 11 -18 -10 PROJECT NAME: MIZUKI JAPANESE BUFFET SITE ADDRESS: 17950 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: In/io1 t VI Public Works A4d r ire Prevention Structural mg- n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -23-10 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: J APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 12 -21 -10 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MONARCH TRADING CORP 2067636161 Po Box 80563 Seattle WA 98108 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600465574 Active MONARTC065Q1 Construction Contractor 11/21/1994 3/6/2011 General Unused Business Owner Information Name Role Effective Date Expiration Date LEE, KING Cancel Date 01/01/1980 Bond Amount WONG, KAI 4 01/01/1980 LPM4078819 WOO, LILY Until Cancelled 01/01/1980 WONG, AMY /2009 01/01/1980 CBIC Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 COLONIAL AM CAS e SURETY OF MARYLAND LPM4078819 08/12/2009 Until Cancelled $12,000.0007/20 /2009 3 CBIC SB0540 02/14/2002 Until Cancelled 08/12/2009 $12,000.00 02/20/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 AMERICAN ECONOMY INS CO 02BP1636127 02/14/2010 02/14/2011 $1,000,000.00 01/22/2010 7 AMERICAN ECONOMY INS CO 02BP1636126 02/14/2009 02/14/2010 $1,000,000.00 02/19/2009 6 AMERICAN ECONOMY INS '02BP163612 CO 02/14/2007 02/14/2009 $1,000,000.00 01/24/2008 5 AMERICAN ECONOMY INS CO 02BP163112 02/14/2005 02/14/2007 $1,000,000.00 01/25/2006 4 AMERICAN STATES INS CO 02BP16316203 02/14/2004 02/14/2005 $1,000,000.00 02/12/2004 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By 07-2-07301-9 BETSCHART ELECTRIC CO INC KING Date: 03/05/2007 Amount: $22,171.00 Date: Amount: $0.00 Dismissed Date: Amount: https://fortress.wa.gov/lni/bbip/Print.aspx 12/13/2010 NOTE: ALL WORK TO CONFORM WITH THE ABOVE CODES OCCUPANCY 15 RESTAURANT, GROUP A -2 5151 SQUARE FEET OCCUPANCY 15 RESTAURANT, GROUP B 2550 SQUARE FEET NO RATED SEPARATION REQUIRED FOR GROUP B AND GROUP A =2 OCCUPANCY EXISTING BUILDING 15 ONE STORY WITH PROPOSED ALTERATIONS TO EXISTING STRUCTURE 2006 INTERNATIONAL BUILDING CODE OCCUPANCY AREA DINING ROOM OCCUPANT LOAD FACTOR: OCCUPANT LOAD: A -2 (3516 sf) 15 234 OCCUPANCY AREA (KITCHEN) B (2166 sf) OCCUPANT LOAD FACTOR: 200 OCCUPANT LOAD: 14.8 CONSTRUCTION TYPE: V -A OCCUPANT LOAD: TOTAL 241 DINING ROOM KITCHEN WAITING AREA OFFICE AREA SUSHI BAR BATH HALLWAY WOMEN'S BATH MEN'S BATH UNISEX BATH SPRINKLER ROOM MEGH ROOM TOTAL 5516 2166 241 71 315 252 256 215 15 8-r 102 8102 SO. FT. Msonkler Blvd. PROJECT LOCATION Main iepaneSe Buffet 17950 Southcenter p � Parkway (Formerly The S FIRE CODE GENERAL NOTES 1.ADDRESS NUMBER SHALL BE PLACED ON THE BUILDING IN A POSITION TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. ADDRESS NUMBER SHALL CO FIR CONTRAST WITH THEIR FOR BACKGROUND ND AN SHALL BE AT LEAST 4 INCHES HIGH. 2. OWNER OWNER, CONTRACTOR PROV E MASTER KEY FOR THROUGHOUT DIRECTED BY THE FIRE MARSHALL. OCCUPANCY. D 3. OWNER, CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS, AND SHALL BE SELECTED, NSTALLED AND MAINTAINED IN ACCORDANCE WITH SECTION 906 OF THE IFC.. AND REXT PERINGU EXTINGUISERS SHALL HAVEOAAMINIMUME A. RATING OF 2A-10BC WITH CURRENT SERVICE TAGS ATTACHED. B WILLEBEXREADILY ACCESSIBLLE.AND IMMEDIATELY AVAILABLESTO USE THESEELOCATIONS SHALL BE ALONG NORMAL PATHS OF TRAVEL. FIRE EXTINGUISERS SHALL NOT BE OBSTRUCTED. C. FIRE EXTINUISHERS SHALL BE HOUSED IN CABINETS OR INSTALLED ON THE HANGER OR BRACKETS. FIRE EXTINGUISERS HAVING A GROSS WEIGHT NOT EXCEEDING 40 LBS. FIRE EXBTINGUISERS HA INGHATGROSSOWEIGHTOEXCEEEDING THAN 60 BSNSHALLABEO ABOVE TOP IS NOT MORE THAN 42 INCHES ABOVE THE FLOOR. THE BOTTOM OF THE FIRE EXTINGUISHER SHALL BE 4 INCHES ABOVE THE FLOOR MINIMUM. D. MAXIMUM TRAVEL DISTANCE TO A FIRE EXTINGUISER SHALL NOT EXCEED 75 FEET. 4. REFER TO FIRE DEPARTMENT PLAN REVIEW REPORT FOR ADDIONAL REQUIREMENTS. ACCESSIBILITY 1. ALL NEW CONSTRUCTION INCLUDING O DOORS, CABINETRY 2 CHAPTER B 1NG FIXTURES TO MEET THE ACCESSIBILITY REQUIREMENTS 1 2. ALL EQUIPMENT FIXTURES, AND CONSTRUCTION AND SHALL BE ADA C BE ACCESSIBLE TO MEET THE ICC /AMSI A117.1 -2003 STANDARDS A. PROVIDE OPERABLE TVBARRIER—FREE RS FOR BARRIER—FREE ACCESS ALONG ROUTES OF TRAVEL A B. MAXIMUM TRESHOLD HEIGHT TO BE 1/2" ALONG ACCESSIBLE ROUTE OF TRAVEL PER SECTION 4.04.2.4 C. PROVIDE MINIMUM18" BEYOND STRIKE .JAMB LATCHINGBLFN, PROVIDE 12" BEYOND STRIKE 404.2.3 IF DOOR IS SELF CLOSING AND JAMB ON OPPOSIT SIDE OF DOOR SWING. FIRE EXTINGUISERS SHALL NOT BE OBSTRUCTED. D. EXCEPT T FOR APPLIANCES, SHALL BE OPERABLE WITH ONE HARDE RDEQUHR D TO AC REQUIRE TIGHT GRASPP RTS PINCHING, BE 5 P0TWISTING UNDS MAX MUMWRIST. THE OPERABLE AND SERVICE E. COUNTERS PUBLIC FOR SALE ORDELIVER PORTION OF THE TCOUNTERG36DINCHES LONG MINIUM BY TO THE PUBLIC SHALL HAVE INCHES MAXIMUN HIGH OABOE DISABLES. FLOOR. A PORTION OF THE RECEPTION COUNTER A L BE ACCESSIBLE TO PER : - - - :'": ALTERATIONS AFFECTING AN AREA CONATINING A PRIMARY FUNCTION BEYOND ITEM 1 ACOVT. OF THE ACCESSIBLE ROUTE IS PRIMARY FUNCTION EXCEED 20 PERCENT OCCTHEIBLE. THE COST OF THE COSTS OF THE ALTERATIONS AFFECTING THE AREA OF PRIMARY FUNCTION. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may i ^::'ude additional plan review fees. • VICINITY MAP PROJECT LOCATION SOUTH CENTER RIMY VICINITY MAP WALE: N. t.& 1 EVitVVED FOR CODE COMPLIANCE APPROVED DEC 10 2010 City :� ..4, la BUILDING D V GENERAL NOTES 1. General Contractor shall verify all conditions and dimensions at job .site, also, review lease agreement with landlord's requirements or con- ditions. If any discrepancies ore found, General Contractor to notify the Architect /Owner. 2. All construction work must confirm to current local codes and au- thorities for building and health departments. 3. General Contractor agrees by accepting contract and starting work that he shall assume sole and complete responsibility for job site conditions during the course of construction including safety of all persons and property. This requirement sholl apply continuously and not be limited to normal working hours. General Contractor shall defend, indemnify and hold owner, architect, designer, engineer and landlord harmless from any and all liability real or alleged, in connection with the performance of work on this project. General Contractor shall show proof of worker's compensation insurance as required prior to issuing a permit. 4. Additional on site fire protection during construction to be provided as required by fire inspector or deportment. Maintain existing fire sprinkler system if applicable to project. . 5. all materials stored on site shall be properly stacked and protected to prevent damage and deterioration until use. Failure to protect materials mya be cause for rejection of work. 6. General Contractor and subcontractors shall be responsible for locating, maintaining, relocating and /or removing existing utilities. 7. General Contractor to provide larger stud wall as required for installation of plumbing, electrical, structural, etc. items. 8. Existing me trriai on demising or interior partition was shall be removed by sub — contractors to allow installation of new work, such as electrical outlets, plumbing lines, etc. After work has been completed, tested and approved wolls shall be covered with 5/8 "type "x" gypsum board, fire taped and prepared for new finishes. General Contractor shall brace entire structure, stairs, storefronts, etc. as required to maintain stability until complete and functioning as o finished instal —. lation and unit. 9. All workmanship and materials are subject to the approval of the architect. designer and owner. 10. General Contractor to install 2x blocking or 1/2" plywood backing in stud walls for installation of equipment, decor, etc. as required. Verify all location with equipment contractor and decor contractor. Although typical equipment and decor details will be provided, it will be the responsibility of each subcontractor to provide integral, complete, final installation which meets local codes and design concet. 11; General Contractor to provide hand fire extinguisher of type and size os required by code and locate as indicated on drawing • (for restaurant use); provide proper indentificotion signs. Install at height not to exceed 5' -0'. Exact number /location by fire inspector, 12. Exit doors shall be left unlocked during all business hours and shall be opened from inside without use of a key or special knowledge or effort. Panic hardware to be provided as per local code requirement. Also, General Contractor to provided signage over each exit door, e.g. "This door shall be remain open during business hours" or " Exit door ". 13. Provide exit sign illumnation per UBC Spec 3312 (c). 14. General Contractor to provide on occupancy sign with maximum person amount as determined by fire /building department mounted on the wall. 15. Public areas, toilet, and public circulation areas shall meet all handicap requirements. All required toilet accessories, equipments, fixtures shall meet height requirements. •Floor plans will allow handicap person full access to all restaurant activities (dining, bar service, toilet, exits, etc.) SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION PROJECT DATA: PROJECT NAME: MIZUKI JAPANESE BUFFET RESTAURANT SITE ADDRESS: 17950 SOUTHCENTER PARKWAY SOUTH TUKWILA, WA , 98188 Tenant contact: JOHN KM WAH 1426 S. 324TH STREET FEDERAL WAY 253- 886 -0943 APN: 3523049123 Legal Description: 3523049123 LOT A of city of Tukwila short plat L99 -0053 recording #2000013190003 Zoning: COMMERCIAL Current use: Retail (vacant) Building type: Masony Built: 1999 Proposed Use: RESTAURANT Occupancy type: A -3 Construction Type:`t*- i/j)r,M'MKQ- ..e�i/i Siesmic zone: 3 . Code: IMC /IBC 2006 Tenant Square footage: 8523 sf FILE C ij PY Permit No., I ' D—� Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize.: the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: -4— BY Date:, { KS)To I 6 City Of 1'�kwita Land Parcel: 2.2654 Acres (including neighboring NewpcnWiNG DIVISION Restaurant. Theater and Parking) Landlord: Madison Investment LLC 1276 N 15th Ave, Suite 103a Bozeman, MT 59715 Sewer — 4" in building, 6" at west corner Water: 1.5" 60 psi Power: 800 amp 120 v / 208 v/ 3 phase Insulation: R13 walls Roof: Metal with foam board above AC: existing 5 gas units each 99,000 btu /hr, 31.5 tons total Scope of Project:- 1) To change use from a vacant retail space to a full service food service establishment per plan. Approval application has been submitted to King County Health Department under a separate cover. 2) Establish use of a buffet style restaurant with approximate seating of 250 persons 3) Propose to add to existing structure an attached covered enclosure at north side with an area of 490 square feet for garbage compactor and dumpster as well as cold storage per plan. The exterior of the addition area will match existing-design with stucco masonry and same color. 4) Two side entrance door with an waiting are enclosure will be added fo the store front entrance area per plan. Application this permit: j Mechanical — Exhaust Hood systems: 5 Type I and 2 Type II dishwashing Vapor per plan Page Index : Ml — M3 Kitchen hood elevation M4 — Roof Plan M5- M10 Hood , exhaust fan, make up fan specifications Supplement: Engineering Seismic bracing calculations. Contractor: Monarch Trading Corporation License no. MONARTC065 Q1 expires 3/14/2011 Contact: King Lee 948 S. Doris Street Seattle, WA 98108 Work :- (206) 763 -6161 / (Mobile) © 206)396 -3173 Email: King @Monarchtradingcorp:com 1 Mi iNAL�NG\ _' �� ' VED NOV 18 2010. ; . PERMIT CENTER j MONARCH TRADING CORPORATION RESTAURANT EQUIPMENT & DESIGN CONSULTANT 948 SOUTH DORIS St. / SEATTLE / WA 98108 TEL 208. 763 -6181 / FAX 206. 783 -6188 LICENSED ¥ INSURED ) BONDED CONSTR. CONTRACT NO.: MONARTC06501 THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETARY TO MONARCH TRADING CORPORATION WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR WRITTEN CONTRACTUAL ARRANGEMENTS WITH MONARCH TRADING CORPORATION. PROJECT- MIZUKI JAPANESE BUFFET 17950 SOUTHCENTER PKWY. TUKWILA, WA 98188 • DRAWING TITLE PROJECT DATA NOTES SITE MAP REVISIONS No. Date Description PROJECT DIRECTOR KTL PROJECT ARCHITECT PROJECT CAPTAIN PROJECT NUMBER APPROVED BY CHECKED BY DRAWN BY * KTL_. DATE~ * JUNE 10,2010. SCALE 1:x-2 —i -0 DRAWING NUMBER P.A 1 NOTE: GC TO VERIFY WITH LANDLORD'S ROOF PENETRATION REQUIREMENT AND ACCURACY OF LOCATION PRIOR TO WORK HANGING ANGLE DETAIL 10'-0" FROM PROPERTY LINE ROOF EXISTING TRUSS RUNS 60' OC NO ALTERATION— SUSPENDED CEILING NO. 1 EXHAUST FAN VENTED CURB/SHAFT BY GC ROOF PENETRATION PATCHING BY OTHERS HANGER RODS 3" air 2'0" VERIFY 8'—O" 3' —6" 3'—O" FIRE RATEISULAIED TOP 11' TYPE ONE WALL CANOPY HOOD (1 ,2,3) CAPTIVE AIRE 541 8ESX2—PSP—FS UL LISTED UL LISTED GREASE FILTER HEAT SENSOR 10'x31' riser FAN NO. 1 AND Na 2 and NO. 3 EXHAUST FAN CAPTIVE AIRE EABDU20 1.5 HP/ 208 V/3 PH/ 4.7 FLAAMP 300 CFM RUNS AT 1" WC AT 911 RPM RAIN CAP 24' 0. 2 EXHAUST FAN RAIN VENTED CURB /SHAFT BY GC •PROTECTED GREASE DUCT 16 GA. GALV. 4LL WELDED 10"x31" or 18'X1 3 or equal a-ea ,...,HANGER RODS HANGER RODS. --. --DUCT ENCLOSURE 10'x31' riser HEAT SENSOR /-11- NO. 3 EX UST FAN RAIN VENTED CURB/SHAFT BY GC /WV Ybat HANGER RODS CEILING DUCT ENCLOSURE — /\ HEAT SENSOR /4- 10'x31' riser ROOF DECK PROTECTED GREASE DUCT 1 6 GA. GALV. ALL WELDED 10"X31" OR EQUAL AREA 1 HR RATED SHAFT (TYP by GC) FOODE COMPLIANCE FiEVIttivtU FOR — L monnvED DEC 1 0 21.1111 City of Tukwila BUILDING DIVISION w EXISTING CEILING ENTIRE HOODS WITH FIRE RATED INSULATED TOP TT ITIT1T11 TT IMITITTFTTT1TTITITITITITTITTTITTITITITITTTIM71 IT 11 -In- IT 11111111111111111111111111111111111111111111111111111 1 j J 11111 /11 11 11111 111111 L111.1J11 L11. LLWJJ fLL LL I J1 JJ1 LL LLLLJ JJ LL L1.1_11 JJ1 LL LLIJJJJ LL J_I_LJ.L. rr rrri rr TT rTIT1 prirT rr rrr TT T1 717 ITI T1 TT rn-pri rr ri-mr rr rT 171 T1 TT 1717171 TT 717171 TT IT M T1 TT IT T1 TI r- 1111111111111111111111101111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 1Luiu.u.I.1-1 ti.1.11-1.L-01-1-H LtJ LII_LI_LJ 1.1 LL111111J_J.0 LL LLIJJ JJ U_IJ1 JJ U_I_LJ JJ LL U_I_LJ 1J LL LII_LJ JJ L LL T--r Tlar S/S WALL FLASHING by GC (OWNER) \1-----e" 0400 0 414 s 01, 041)11) 11441)0 0000 • 0 0 0 0 0 0 0 0 rj) 3' AIR 1/2' DIA, ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE STEEL HANGING ANGLE 1/2 DIA, HEAVY DUTY NUT AND WASHER - ONE ABOVE AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE-PUNCHED AT FACTORY x 5/8"—GWB / TYPE X 2-1/2 METAL STUDS 14X14 OPENING ALL WELDED GALVANIZED DUCT 220 SQ. IN. (OR EQUAL AREA DUCT) 3" AIR SPACE ALL AROUND TYP. SHAFT DETAIL SCALE: NTS 24' CONVECTION OVEN (DOUBLE) (140K btu) (light duty) GAS FAT FRYERS (3) 110K btu (3) (heavy duty) WOK RANGES (Medium duty) 7x110K btu 33,-0" 1/2' STEEL BANDING 1/2' STEEL BANDING OVERLAPPED ARE 11' LL WELDED DUCT 21' TYP. 53.3 CM 10-1/2' 26.7 CM -1/2' 1-1/2' TYR FIRF WRAP EIVERI AY SFCTIDNAL PI AN (ONLY IF USED) (3M 15A FIRE BARRIER FIRE BLANKET — 1 — 2 HR RATED ) N.T.S. 24' FRONT ELEVATION SCALE: 1/2"=1'-0" 11' BACK KITCHEN HOOD (No. 1,2,3) OTES: 1 10 BURNER HOT PLATE (Medium duty) (8X32K btu) 11' RICE RICE COOKER COOKER (light (light duty) duty) (35K (35K btu) btu) 1. EXHAUST HOOD IS UL 8( NSF LISTED. ALL WELDED S/S TYPE 1 CANOPY 2. EXHAUST FAN AND MAKE UP AIR FAN TO BE ELECTRICALLY INTERLOCKED.<------- t,t, rat cAvAttAe 6364 3. FIRE SUPPRESSION BY OTHERS. WORK WILL CONFORM TO UL 300, NFPA96, ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENTS, 4. IN SOME INSTANCE, IN LIEU OF A FIRE SHAFT A 1 TO 2 HOUR FIRE RATED FIRE WRAP SUCH AS 3M FIRE BARRIER CAN SUBSTITUTE THE SHAFT,PROVIDED THE WORK TO BE DONE BY A CERTIFIED INSTALLER ONLY IF USED IN LIEU OF SHAFT) SPACE 18" GREASE CAN 10'O" EXISTING METAL ST D WALL RECEIVED NOV 182010 PERMIT CENTER 5. FIRE ALARM LOW VOLTAGE HOOK UP IS REQUIRED TO TIE IN WITH FIRE SUP. SYSTEM BY OTHERS. 6. GAS PLUMBING MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL AUTOMATIC GAS SHUT OFF VALVE AT PROPER LOCATION TO TIE IN WITH FIRE SUPPRESSION SYSTEM. 7. IMC 507.2.11 - TYPE 1 HOOD SYSTEM SHALL AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR BT MEANS OF A HEAT SENSOR OR OTHE APPROVED METHODS. MONARCH TRADING CORPORATION RESTAURANT EQUIPMENT & DESIGN CONSULTANT 948 SOUTH DORIS St. / SEATTLE / A 98108 TEL 206. 763-6161 / FAX 206. 763-6168 CONSTR. CONTRACT NO.: MONARTC08501 THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETARY TO MONARCH TRADING CORPORATION WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR WRITTEN CONTRACTUAL ARRANGEMENTS WITH MONARCH TRADING CORPORATION. MIZUKI JAPANESE BUFFET 17950 SOUTHCENTER PXCWY TUKWILA, WSHINGTON HOOD PLAN (1,2,3) SHAFT DETAIL L;) i I , 101018 I • • I • KTL I 10-18-2010 1/2"=1'-0" • N/10 NOTE: GC TO VERIFY WITH LANDLORD'S ROOF PENETRATION REQUIREMENT AND ACCURACY OF LOCATION PRIOR TO WORK TERMINATI ❑N w CD x w ROOF EXHAUST FAN NO. 4 CAPTIVEAIRE EABDU24 3.0 HP 208V / 60 / 3 PH /9.5 AMP 4400 CFM @ 1.30' VC. AT 840 RPM 101-ILAINLIELERE EXTEND GREASE DUCT ABOVE ROOFE CQ HINGED BASE 10'- " MTN. TI1 ANY TNTAKF AIR 16 GA. GALV. ALL WELDED DUCT 16 OR EQUAL AREA DUCT VENTED METAL CURB GC'S ROOFER TO FLASH & SE OPENING PROPERLY o GREASE COLLECTOR 1 HOUR RATED SHAFT BY OWNER /GC =-> AIR VENT HANGER RODS ROOF /VW FIRE RATED CLEAN r T ACCESS PANEL HANGING.RODS ----O (4) TYP 10'x21' RISER HORIZONTAL DUCT RUNS 1/4' PER FOOT DROP 10'x21' RISER 0 3,- 14' / / 18' 22 GA. S/S WALL FLASHI G OVER STUD WALL WITH 5/8' TYPE X GWB FINISH FLOOR 16' -0" ALL S/S TYPE I CANOPY HOOD (N0,4) CAPTIVE AIRE MODEL 5424EX- 1 -PSP -F (UL LISTED) CI 0 0 / 18 "/ 0) rain overhang STEAM RANGE COMM OVEN (ELECTRIC) —GAS FRYER 16'0" GAS BROILER (W COVERS) 5' 6' MIN overhang OPEN KITCHEN HOOD (No. 4) FRONT ELEVATION SCALES 1/2 " =1' -0' EXHAUST FANS FOR HOOD NO. 4 EXHAUST FAN N❑.4 CAPTIVEAIRE EABDU24 3,0 HP 208V / 60 / 3 PH /9.5 AMP 4400 CFM @ 1.30' WC. AT 840 RPM EXISTING TRUSS RUNS 60' OC — HINGE (TYP) EXHAUST FANS FOR HOOD NO.1 HOOD NO.2 HOOD NO.3 EXHAUST FAN (3 EACH) CAPTIVE AIRE EABDU20 1.5 HP/ 208 V/3 PH/ 4.7 FLAAMP 3300 CFM RUNS AT 1" WC AT 911 RPM FAN _ ND. 4 ALL WELDEI_ RISER DUCT 20 "X20' SENSOR O'X21" (2) 0 10'-0" MIN. TO ANY INTAKE AIR 16 GA. GALV. ALL WELDED DUCT 18" X 18" OR EQUAL. (3 EACH) N HANGING RODS (4) FIRE RATED 1 HOUR SHAFT GC FAN NO. 4 MAKE UP AIR FAN CAPTIVE AIRE EA -A4 -920 5 HP. 208 V/3 PH./14.1 FLA 8910 CFM RUNS ®1.0 "WC AT 575 RPM ROOF CURB BY GENERAL CONTRACTOR PATCHING BY OTHERS ROOF LINE U 12 "THERMAL FLEX( TYP 4) HEAT MAKE UP AIR DUCT SENSOR 27'X27' GALV. ADAPTOR — REVIEWED FOR CODE COMPLIANCE noVED DEC 10 City of Tukwila BUILDING DlVisiniN GREASE CAN 3" AIR SPACE OPEN KITCHEN HOOD ER 10'X31' GREASE CAN GRANDVIEW CAPTIVEAIRE 5418ESX- 2— PSPS —FS (3 EACH) 18 GA. S/S ALL WELDED 12' -0" LONG 5600 CFM WELDED COMPENSATING CANOPY EXHAUST HOOD S/S WALL FLASHING " METAL STUD WALL 22' 80" typ MAIN KITCHEN HOODS(3X11') SIDE ELEVATION SCALE: 1/2"=1'-0" RECEIVED 18 2010 PERMIT CENTER z 0 F- z _ Ce =o w MONARCH TRADING CORPORATION RESTAURANT EQUIPMENT & DESIGN CONSULTANT 948 SOUTH DORIS St. / SEATTLE / 1IA 98108 TEL 206. 783 -6161 / FAX 206. 763 -6168 CONSTR. CONTRACT NO.: MONARTC06501 THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETARY TO MONARCH TRADING CORPORATION WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR WRITTEN CONTRACTUAL ARRANGEMENTS WITH MONARCH TRADING CORPORATION. MIZUKI JAPANESE BUFFET 17950 SOUTHCENTER I'Iili Y TUKWILA, WSHINGTON HOOD PLAN (4,5) HOOD SIDE VIEW 101018 KTL 10 -18 -2010 1/2 " =1' -0" d NN.. M10 ROOF 10 40' MIN HOOD FAN TERMINATION TO ROOF 3" AIR SPACE INE 10'- FAN NO. 5 HANGING ROBS (4) TYP 15'6" VERIFIED FINISH FLOOR 16 GA. GALV. ALL WELDED DUCT. 18'X20° FIR_ RATED CLEAN i T ACCESS PANEL 14'x20' RISER PSP MUA ASSY. f " MTN. TN ANY TNTAKF . AIR RAIN CAP _L- CURB BY OWNER /GC ---AIR SPACE HORIZONTAL DUCT RUNS 1/4' PER FOOT DROP 14'X20' ISER HOOD NO. 5 CAPTIVEAIRE 5424EXI- PSPFBSS 13' -0" ALL S/S TYPE I UL LISTED ISLAND COMPENSATING HOOD J '6" 24" COUNTER AREA Non - combustible fire rated Insulation behind cook[Ing. & side walls by GC -2Q3 7g2 4L1u —�— �- 41)-- U 80 "TYP 16'dJ 48" Griddle 48" Griddle 13' -0" 4' STEAM TABLE 6 "MIN, OVERHANG i 6 "MIN OVERHANG OPEN KITCHEN ISLAND HOOD (No. 5) FRONT ELEVATION SCALE: 1/2"=1'-0" 5 /8 " -GWB / TYPE X 2 -1/2 METAL STUDS 20"X18" ALL WELDED 16 GA. GALVANIZED DUCT 360 SQ. IN. (OR EQUAL AREA DUCT) 3" AIR SPACE ALL AROUND UL SHAFT DETAIL (TYP) (not used) SCALE: NTS RAIN CAP 10' INE M ETAL VENTED CURB 3" AIR SPACE ALTERNATVIE FIRE WRAP IN L EU OF SHAFT, SEE DETAILS EMS DUCT SENSORI (By CaptiveAlre FIELD INSTALL 1 PER RISER System) 1 /2' Qulk Seal (Adapter Body) Part #32 -000Oa 1/2' Qulk Sea (Gasket) Part #32 -00002 rease Duct (External Surface) DUCT T —STAT 1 1/8' - 1 1/4' Diameter Hole Resistance Temperature Detector Part # ACl/ 100- #w- 1 -4'NW HTF 1/2' Qulk Seat (Nut) 1/2' Qulk Seal (Lock Washer) Part # DUCT ZT -STAT Part #32 -00002 ❑PERATI ❑N STAT' ACTIVATS FAN AT 85 DEGREES. FAN OPERATES FOR 30 MIN. AFTER DUCT TEMP DROPS BELOW SET POINT ALL WELDED 16 GA GALV. DUCT 20'X18' MUA FROM FAN NO.5 DAMPER U.L. LIGHTS U.L. FILTERS PICK UP COUNTER (GC) INSULATION (GC HEAT SENSOR AIR EXHAUST FAN FOR HOOD NO.5 EABDU24 CAPTIVEAIRE 5 HP 208V / 60 / 3 PH /14.1 FLAmp 5850 CFM 1.5" W.C. AT 989 RPM 14'X20' ALL WELDED RISER(2) ROOF PENETRATION & PATCHING BY LANDLORD'S DESIGNATED CONTRACTOR AIR VENT 16 GA. GALV. `1 /2" (TYP) HANGER RODS ROOF CURB AND FLASHING BY GENERAL CONTR CTOR ROOF FAN NE,3 MAKE -UP AIR FAN A3D7502 -G18 CAPTIVEAIRE 5 HP / 208 V / 60 / 1 PH 6500 CFM ® 0.75" W.C. AT 861 RPM/ 14.1 amp SONE& 41 DBA FRESH ��AIR INTAKE 40' MIN HOOD DIFFUSETERMINATION TO ROOF S.S. GREASE CUP GAS GRILL /MUA ADAPTOR 12" DIAM, THERMALFLEX MAKE UP AIR DUCT (TYP 4) CAPTIVEAIRE S/S PERFORATED PSP MUA ASSY. 18 GA. S/S ALL WELDED UL LISTED CANOPY EXHAUST HOOD #5 CAPTIVE AIRE MODEL 5424EXI 18 GA. S/S ALL 3'6" 36" L12" 5 4" 12 "—I HOOD OVERHANG 12' i (FINISH FLOOR SIDE ELEVATION (HOOD No.5) SCALE: 1/2"=1'-0" C0� WEL*0 FOR` ODE COMPLIANCE DEC 1 u 2U rd City of Tukwila oivi.Sinm MONARCH TRADING CORPORATION RESTAURANT EQUIPMENT & DESIGN CONSULTANT 948 SOUTH DORIS St. / SEATTLE / WA 98108 TEL 206. 763 -6161 / FAX 206. 763 -6168 CONSTR. CONTRACT NO.: MONARTCO65O 1 THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETARY TO MONARCH TRADING CORPORATION WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR WRITTEN CONTRACTUAL ARRANGEMENTS WITH MONARCH TRADING CORPORATION. MIZUKI JAPANESE BUFFET 17950 SOUTHCENTER PKWY TUKWILA, WSHINGTON HOOD PLAN (5) SHAFT DETAIL SENSOR DETAIL 2009 IMC 507.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508.1 MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically ,. -i terlocked to insure that makeup air is provided hen ever the exhaust system is in operation. Makeup air intake opening locations shall comply with Section 401.4. � 1 OTES: VELOCITY IS 4220 CFM /(18" 0 ")= 4220 CFM /2.5 SF = 1668 FT /MIN WITH IN RANGE 1. EXHAUST HOOD IS UL & NSF LISTED. ALL LIQUID TIGHT WELDED S/S TYPE 1 ISLAND CANOPY 2. EXHAUST FAN AND MAKE UP AIR FAN TO BE ELECTRICALLY INTERLOCKED. 3. FIRE SUPPRESSION BY OTHERS. WORK WILL CONFORM TO UL 300, NFPA96, ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENTS. 4. ALL ELECTRICAL APPLIANCES UNDER HOOD HAVE TO BE SHUT DOWN WITH MUA AT TIME OF FIRE SUPPRESSION SYSTEM TRIPPED. 5. IN LIEU OF A FIRE SHAFT A 1 TO 2 HOUR FIRE RATED FIRE WRAP SUCH AS 3M FIRE BARRIER MAY SUBSTITUTE THE SHAFT, WORK TO BE DONE BY A CERTIFIED INSTALLER. 6. ELECTRICAL AND PLUMBING WORKS ARE DONE BY OTHERS UNDER SEP, PERMITS 7. GAS PLUMBER TO INSTALL AUTO SHUT OFF VALVES AND TIE TO FIRE SUPPR, SYSTEM 8. ROOF PATCHING BY LANDLORD'S DESIGNATED CONTRACTOR HOOD RECEIVED NOV 182010 PERMIT CINTTR 101018 1/2 " =1' -0" M10 119' -4" GRIDDL 85 -0" O O 0 O O 0 5' 4" 2' -0" — —1- 22' -0" 5' 4" 1 ' 9 -3/4" 16' 6 -1/4" 5' 4" 13' -4" 5' 4" 26' -0" ROOF ACCESS make up air MAIN KITCHEN Fan No. 2 PARAPET ALL AROUND 11' Ho o d( No.1) EX FAN #1 (2nd) 10 feet from air intake 11' 11 o o d (N4.2) -,— Ex Fan No. 1 (3rd unit) 11' Hood (N41.3) I1 J 1- 9' -6" Q Q 16 -6" , 2'9 -3/4" 18' 7 -1/4" 1 6' HOOD WALL CANOPY (no.4) OPEN KITCHEN FAN UNIT NO.3 EXHAUST GRIDDLE Hood No. 1 6 1 conde: ioale -J Ex Fan No. 6 (Type 2 Vapor) Scullery Area Hood No. r 7 condensate I i 1 Ex Fan No. 7 (Type 2 Vapor) L 10 feet from air intake FAN UNIT NO.4 EXHAUST Fan No. 5 make up air HOOD NO.5 TYPE I ISLAND CANOPY Min. 10 feet from air intake 9' 5 -1/8" AEviivvLu FOR CODE COMPLIANCE Gay of Tukwila BUILDING DIVISION gj 1013.5 Mechanical Equipment. Guards shall be provided where appliances, equipment, fans, roof hatch opening or other components that require service are located within 10- feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30- inches above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21- inch - diameter sphere. The guard shall extend not less than 30- inches beyond each end of such appliances, equipment, fan or component. 1013.6 Roof Access. Guards shall be provide where the roof atch opening is located within 10 -feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30- inches above the floor, roof or grade below. The guard shall be constructed so as to prevent the passage of a 21- inchdiameter sphere. 13'-4" 5'-4" 35' -4" 5 -4" 17950 Southcenter Parkway Tukwila, Wa 119'-4" ROOF EQUIP PLAN T SCALE: 1/4"=V-0" 22' 0" 5' -4" 18' 5 -7/8" 22' -0" 5' -4" 1 18' 5 -7/8" - 9' 5 -1/8" 20' -5" 5' 4" 22' -0" 5' 4" 81' -0" • 24 "X36" RECEIVED NOV 18 2010 PERMIT CENTER MONARCH TRADING CORPORATION RESTAURANT EQUIPMENT & DESIGN CONSULTANT 948 SOUTH DORIS St. / SEATTLE / EA 08108 TEL 208. 783 -8181 / FAX 208. 783 -8188 LICENSED • INSURED • BONDED CONSTR. CONTRACT NO.: YONARTC08501 THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETARY TO MONARCH TRADING CORPORATION WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR WRITTEN CONTRACTUAL ARRANGEMENTS WITH MONARCH TRADING CORPORATION. PROJECT MIZUKI *BUFFET • 17950-SOUTHCENTER_PKWY TUKWILA,WA_98188 DRAWING TITLE ROOF_EQUIP_PLAN * REVISIONS No. Date Description PROJECT DIRECTOR DIRECTOR PROJECT ARCHITECT ARCHITECT PROJECT CAPTAIN CAPTAIN PROJECT NUMBER PROJECTNUMBER APPROVED BY APPROVED CHECKED BY CHECKED DRAWN BY DRAWN DATE 1JAN92 SCALE 3/16 " =1' -0" DRAWING NUMBER 4 OF M10 HOOD INFORMATION HOOD NO MODEL LENGTH MAX, C❑ ❑KING TEMP, EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD C❑NFIG, TOTAL EXH, CFM RISER(S) TOTAL SUP, CFM RISER(S) END TO END ROW WIDTH LENG, DIA, CFM S.P. WIDTH LENG, DIA, CFM S.P. 1 5418 ESX -2- PSP -FS 11' 0,00' 600 Deg, 3300 10' 31' 3300 - 0,677' 2970 3 NO 903 LBS 5 16' 430 SS Where Exposed LEFT BACK 2 16' 16' 4 Incandescent Light Fixt NO 4 RIGHT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 2 5418 ESX -2 -PSP -F 11' 0.00' 600 Deg, 3300 10' 31' 3 3300 -0.677' 2640 16' 4 Incandescent Light Fixt NO 430 SS Where Exposed MIDDLE BACK Wide Insulated NO LBS 5 16' 20' 4 SS Baffle with Handles 2 3 5418 r ESX -2- PSP -FS 11' 0.00' 600 Deg, 3300 10' 31' 1028 3300 -0.677' 2970 NO LBS 8 16' 20' 430 SS Where Exposed P RIGHT BACK 16' 16' 8 Screw In Compact Fluore NO 12' 28' 1173 0,149' 4 5424 EX -1 -PSP -F 16' 0,00' 600 Deg, 4400 10' 21' 2200 - 0,512' 3520 0 158' 12' 6' 8' 430 SS Where Exposed ALONE ALONE 10' 21' 113 LBS 2200 - 0,512' 7 16' 587 5 5424 EXI- PSP -FBSS 13' 0,00' 600 Deg, 5850 14' 20' 16' 2925 - 0,505" 5265 143 LBS Front 158' 12' 6' 430 SS Where Exposed ALONE ALONE 14' 20' 2925 -0.505' 8' 16' 6 3624 ES -VHB -G 3' 0,00' 700 Deg, 450 10' 450 - 0,051' 0 0,122' Left 78' 12' 304 SS 100% ALONE ALONE 10' 290 0.053' 7 3624 ES -VHB -G 5' 0.00' 700 Deg, 750 10' 750 -0.113' 0 290 0,053' Right 78' 304 SS 100% ALONE ALONE 10' 290 0,053' HOOD N❑, FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM PIPING HOOD HANGING WGHT TYPE QTY, HEIGHT LENGTH QTY, TYPE WIRE GUARD L ❑CATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY L❑CATI ❑N 1 SS Baffle with Handles 2 16' 16' 4 Incandescent Light Fixt NO 0,146' Left 70' 16' 3 NO 903 LBS 5 16' 20' 2 SS Baffle with Handles 2 16' 16' 4 Incandescent Light Fixt NO 4 RIGHT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High NO 887 LBS 5 16' 20' 3 SS Baffle with Handles 2 16' 16' 4 Incandescent Light Fixt NO 969 5 LEFT END STAND❑FF(FIN /INS- ISLAND) 1' Wide Insulated NO LBS 5 16' 20' 4 SS Baffle with Handles 2 16' 16' 5 Incandescent Light Fixt NO 20' 1028 0,163' 4 Front NO LBS 8 16' 20' 5 SS Baffle with Handles 2 16' 16' 8 Screw In Compact Fluore NO 12' 28' 1173 0,149' NO 832 LBS 14 16' 20' 6 1173 0,149' 5 0 158' 12' 6' 8' 16' 587 0,122' NO 113 LBS 7 16' 587 0,122' 0 8' 16' 587 NO 143 LBS Front 158' 12' HOOD N❑, OPTION LENGTH WIDTH HEIGHT RISER(S) WIDTH 1 TOP INSULATI ❑N CFM S.P. 1 Front 132' 16' INSULATION FOR BACK STANDOFF 12' 20' 970 0.146" 2 TOP INSULATI ❑N 12' 20' INSULATI ❑N FOR BACK STANDOFF 0,146' Left 70' 16' 3 TOP INSULATION 20' 1029 0,163" 2 Front INSULATION FOR BACK STANDOFF 16' 6' 12' 28' 4 RIGHT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 430 SS 12' LEFT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 430 SS 132' INSULATI ❑N FOR BACK STANDOFF 6' 12' 20' 969 5 LEFT END STAND❑FF(FIN /INS- ISLAND) 1' Wide Insulated 12' 20' RIGHT END STAND❑FF(FIN /INS- ISLAND) 1' Wide Insulated Right 70' PLENUMS HOOD N❑, P ❑S, LENGTH WIDTH HEIGHT RISER(S) WIDTH LENG, DIA, CFM S.P. 1 Front 132' 16' 6' 12' 20' 970 0.146" 12' 20' 970 0,146' Left 70' 16' 6' 12' 20' 1029 0,163" 2 Front 132' 16' 6' 12' 28' 1314 0,185' 12' 28' 1314 0,185' 3 Front 132' 16' 6' 12' 20' 969 0,145' 12' 20' 969 0,145' Right 70' 16' 6' 12' 20' 1028 0,163' 4 Front 192' 16' 6' 12' 28' 1173 0,149' 12' 28' 1173 0,149' 12' 28' 1173 0,149' 5 Back 158' 12' 6' 8' 16' 587 0,122' 8' 16' 587 0,122' 8' 16' 587 0,122" Front 158' 12' 6' 8' 16' 587 0,122' 8' 16' 587 0,122' 8' 16' 587 0,122' Left 78' 12' 6' 10' 290 0.053' 10' 290 0,053' 10' 290 0,053' Right 78' 12' 6' 10' 290 0,053' 10' 290 0,053' 10' 290 0.053' FIELD CUT EXHAUST RISER HANGING ANGLE 16' SS BAFFLE WITH HANDLES AND HOOK 1' LAYER OF INSULATI ❑N FACTORY INSTALLED IN 3' INTERNAL STANDOFF, MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES, IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP ►J r - 54' ExternalDuctSirface) pier Body) 1/8' - 1 1/4' Diameter Hole Port auk - 0000�(Casket) 1/2' t° 32 o Seat `(.ack Washer) auk Seal alit) Part i32 -00002 De�e��. Temperature Part i ACV100- #e-1 -4 NV HfF DUCT T -STAT INCANDESCENT LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) -1111111111 27' MIN, EQUIPMENT BY OTHERS 1' LAYER OF INSULATION FACTORY INSTALLED ON TOP OF HOOD. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 3/4' 23,5% OPEN STAINLESS STEEL PERFORATED PANEL 16' ,' 6" - 18' NOM, 48,0' MAX 98' 80' AFF TYP, %r Alb SECTION VIEW — MODEL 5418SND -2— PSP —FS 1CODE VjEvvEd FOR-.' COMPLIANCE PO -nnveo DEC 1 u 2Uiu City of Tukwila BUILDING DIlfig ni SND -2 Series with PSP Accessory Specification The SND -2 series hood with PSP accessory Is o. low proximity compensating hood system. The hood shall have the size, shape and performance specified on drawings. Construction shall be type 430 stainless steel with a #3 or #4 polish where exposed. Individual component construction shall be determined by the manufacturer and ETL, Construction shall be dependent on the structural application to minimize distortion and other defects. All seams, ,Joints and penetrations of the hood enclosure to the lower outermost perimeter that directs and captures grease -laden vapor and exhaust gases shall have a liquid -tight continuous external weld in accordance with NFPA 96. Hood shall be wall type with fully welded 10 gauge corner hanging angles. Corner hanging angles have a .625 x 1.500 slot pre - punched at the factory, allowing hanging rods to be used for quick and safe Installations. Hanging rod and connection Is provided by and installed by others. Ventilator shall be furnished with U.L. classified aluminum baffle filters, supplied In size and quantity as required by ventilator, The filters shall extend the full length of the hood and the filler panels shall not be more than 6' In width, The hood manufacturer shall supply complete computer' generated submittal drawings Including hood section view(s) and hood plan vlew(s). These drawings must be available to the engineer, architect and owner for their use in construction, operation and maintenance, Exhaust duct collar to be 4' high with 1' flange, Duct sizes, CFM and static pressure requirements shall be as shown on drawings. Static pressure requirements shall be precise and accurate) air velocity and volume Information shall be accurate within 1 -ft Increments along the length of the ventilator, U.L. Incandescent light fixtures and globes shall be Installed and pre -wired to a ,Junction box. The light fixtures shall be Installed with a maximum of 4'0' spacing on center and allow up to a 100 watt standard light bulb, The hood shall have' -A double wall insulated front to eliminate condensation and Increase rigidity. The Insulation shall have a flexural modulus of' 475 EL meet UL 181 requirements and be In accordance with NFPA 90A and 90B. -An Integral front baffle -to direct grease laden vapors toward the exhaust filter bank, -A built -In wiring chase provided for outlets and electrical controls on the hood face and shall not penetrate the capture area or require an external chaseway, -Low velocity make -up air (up to 90%) is • provided through front and side plenums (PSP accessory). -A removable grease cup for easy cleaning, The hood shall be ETL Listed as 'Exhaust Hood Without Exhaust Damper', ETL Sanitation Listed and built In accordance with NFPA 96, The hood shall be listed for 450 °F cooking surfaces at 228 CFM /ft and 600 °F cooking surfaces at 294 CFM /ft, RECEIVED NOV 18 2010 PERMIT CENTER REVISIONS DESCRIPTION DATE: A 0 A 0 II"1" 11 II 1111111 I ih 142 Nft 1Nft 1 z U Lr) N_ Tukwila, WA iveaire.com SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com DATE: 1 1/05/2010 DWG. #: 1164581 DRAWN SCALE: 1/16 MASTER DRAWING SHEET M®. 54' 35' 35' 3.J 16' PLAN VIEW — Hood #3 11' 0.00" LONG 5418SND- 2— PSP —FS 33" 1' 0.00 "Nora. /11' 0.00' ❑D 20' 66' PLAN VIEW — Hood #2 11' 0.00" LONG 5418SND -2 —PSP —F 20" 33" 33' _ 11' 0,00'Nom, /11' 0.00'0D 28" 66' PLAN VIEW — Hood #1 11' 0.00" LONG 5418SND -2— PSP —FS 28" 33' tIo11 33' 20' 1' 0,00'Nom, /11' 0.00'0 66' 16' 0 t1 o11 0 u 0 20' 8" 0 U.L. Listed Incandescent Light Fixture -High Temp Assembly 1 C U.L. Listed Incandescent Light Fixture -High Temp Assembly FI ld Cit ///,F01 ld Cut i i l X 3 t U.L. Listed Incandescent Light Fixture -High Temp Assembly 20' 8' r3' 16" 35' 54' 35' EXHAUST RISER HANGING ANGLE 16" SS BAFFLE WITH HANDLES AND HOOK 1" LAYER OF INSULATION FACTORY INSTALLED IN 3" INTERNAL STANDOFF, MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES, IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP LEFT AND RIGHT QUARTER END PANELS 54' SCREW IN COMPACT FLUORESCENT BULB, INCANDESCENT LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 2 3/4' 23" 23" EQUIPMENT BY OTHERS 16" 23.5% OPEN STAINLESS STEEL PERFORATED PANEL 24' NOM. 48.0" MAX SECTION VIEW — MODEL 5424ND -1 —PSP —F 104' 80' AFF TYP, 54' 16" 10' 21' U.L. Listed Screw In Compact Fluorescent Bulb 10' 21' t 11 12" 12' 12' 32' 48' 28" 64' 28" 96' 8' 28' 16' 0,00 "Nom. /16' 0.00' 0D 64' 48' 8' — 32' PLAN VIEW — Hood #4 16' 0.00" LONG 5424ND -1 —PSP —F N❑TE1 Additional hanging angles provided for hoods longer than 12 ft. REVIEwth FOR CODE COMPLIANCE DEC 10 200 City of Tukwila BUILDING DR IISinm RECEIVED NOV 18 2010 PERMIT CENTER 1— REVISIONS DESCRIPTION DATE: 0 A D A 1 SEATTLE OFFICE U ca u, co rn 2 w co rn o) U) N �i 0 rn rn N N rf (N1 W z 0 N rb a) 1- W W w M 0 M W 1- LLI 0 Z 0 0 N U 0 Bu-F-Fe± -17950 N_ S 03 CO CO Tukwila, WA. DATE: 9/20/2010 DWG. #: 1164581 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET NO. 6 FIELD CUT EXHAUST RISER HANGING ANGLE ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 54' SCREW IN COMPACT FLUORESCENT BULB, INCANDESCENT LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE 23.5% OPEN STAINLESS 2 3/4' STEEL PERFORATED PANEL 6' ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 2'75' 23,5% OPEN STAINLESS STEEL PERFORATED PANEL IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 16' SS BAFFLE WITH HANDLES AND HOOK I--- 12' -- GREASE DRAIN WITH REMOVABLE CUP EQUIPMENT BY OTHERS 12' 6' 48.0' MAX : 24' NOM, 104' 80' AFF TYP. SECTION VIEW — MODEL 5424EXI— PSP —FBSS HOOD — #5 ETL LISTING DESCRIPTION BLOCK THE CAPTIVE AIRE MODEL NDI HAS BEEN E.T.L. TESTED, LISTED, AND APPROVED TO EXHAUST A MINIMUM OF 422 CFM PER LINEAR FOOT OVER 600 DEGREE COOKING EQUIPMENT ETL RATINGS (PER UL 710): FILE # 3054804 -001 MAX. TEMP. MIN. EXH, CFM /FT MAX. MAU, CFM /FT LENGTH RANGE MAX. LEN. FOR 1 RISER WIDTH RANGE WIDTH INCR, SIDE OVERHANG FRONT OVERHANG VERT, CLEARANCE (WITH LIGHTS) VERT, CLEARANCE (W /❑ LIGHTS) ''�j MODEL: NDI (WITH & W/O PSP) 450 DEG. 346 CFM /FT - 3' -20' 12' 48' -84' 1' 6' 12' 33' -48' 11.5' -48' 600 DEG, 422 CFM /FT - 3' -20' 12' 48' -84' 1' 6' 12' 33' -48' 11.5' -48' 700 DEG. 475 CFM /FT - 3' -20' 12' 48' -84' 1' 12' 12' 33' -48' 11.5' -48' 10' APPROVED FILTER TYPES: ALUM, BAFFLE, SS BAFFLE, HE SS BAFFLE, SPARK ARRESTOR BAFFLE, CAPTRATE (2 STAGE), AND HV CARTRIDGE PERFORMANCE: NDI (WITH & W/O PSP) MAX, AVG. C❑ ❑KING SURFACE TEMPERATURE (DEG. F) / C❑ ❑KING SURFACES C ❑NFIGURATI ❑N MIN. EXHAUST CFM /FT SUGGESTED SUPPLY CFM /FT, VIA FRONT SUPPLY PLENUM 450 DEG. - OVENS, STEAMERS, KETTLES, OPEN-BURNER RANGES GRIDDLES, AND FRYERS ISLAND HOOD 346 275 i 0 III • yam ''�j 600 DEG. -GAS CHARBROILERS ELECTRIC CHARBROILERS, AND WOKS ISLAND HOOD 422 335 i 700 DEG.- MESQUITE GRILLS CHARCOAL CHARBROILERS GAS CONVEYOR CHARBROILERS ISLAND HOOD 475 380 * *SUPPLY CFM /FT CONSULT FACTORY REPRESENTIVE IF HIGHER VALUES ARE REQUIRED NDI Series Specification The NDI series hood Is an exhaust only Island hood rated for all types of cooking equipment, Hood shall have size, shape and performance specified on drawings. Construction shall be type 430 stainless steel with a #3 or #4 polish where exposed, Individual component construction shall be determined by manufacturer, ETL, and NSF. Construction shall be dependent on the structural application to minimize distortion and other defects. All seams, joints and penetrations of the hood enclosure to its lower outermost perimeter that directs and captures grease -laden vapor and exhaust gases shall have a liquid -tight continuous external weld In accordance with NFPA 96. Hood shall be wall type with a minimum of four connections for hanger rods. Connectors shall have 9/16' holes pre - punched In angle Iron at the factory to allow for hanger rod connection by others. Ventilator shall be furnished with UL classified baffle filters, supplied In size and quantity as required by ventilator. The filters shall be centered front -to -back In a V -bank configuration. They shall extend the full length of the hood and the filler panels shall not be more than 6' In width. The hood manufacturer shall supply complete computer generated submittal drawings including hood section view(s) and hood plan view(s). These drawings must be available -to the engineer, architect and owner for their use in construction, operation and maintenance. Exhaust duct collar -to be 4' high with 1' flange. Duct sizes, CFM and static pressure requirements shall be as shown on drawings, Static pressure requirements shall be precise and a ccur atej air velocity and volume Information shall be accurate within 1 -ft Increments along the length of the ventilator. UL incandescent light fixtures and globes shall be installed and pre -wired to a junction box, The light flxtures shall be Installed with a maximum of 4'0' spacing on center and allow up to a 100 watt standard light bulb. The hood shall have -A double wall Insulated front and back to eliminate condensation and increase rigidity. The Insulation shall have a flexural modulus of 475 EI, meet UL 181 requirements and be In accordance with NFPA 90A and 90B. -An integral baffle on the front and back to direct grease laden vapors toward the exhaust filter bank. -A built -In wiring chase provided for outlets and electrical controls on the hood face and shall not penetrate the capture area or require an external chaseway, -A grease drain system which shall be an enclosed integral part of the hood filter bank and slope to an exposed, removable M pint grease cup to facilitate cleaning. The hood shall be ETL Listed as 'Exhaust Hood Without Exhaust Damper', NSF Listed and built In accordance with NFPA 96. The hood shall be listed for 400 °F cooking surfaces at 346 CFM /ft, 600 °F cooking surfaces at 422 CFM /ft, and 700 °F cooking surfaces at 475 CFM /ft, 1' LAYER OF INSULATI ❑N FACTORY INST 1.00' END STAND❑F MEET 0' REQUIREMENTS CL ARANC TO COMBUSTIBLE suagFACEf3' 54' 26' 26' 12' 1 1 13' 27' 16' 6' 52' 16' 6' 52' 27' 6' -- 12' 1' 27' 16' 6' 52' 16' 6' 13' 0,00'Nom, /13' 0.00' 0D 52' 16' 6' 27' PLAN VIEW — Hood #5 13' 0.00" LONG 5424EX1— PSP —FBSS NOTE! Additional hanging angles provided for hoods longer than 12 ft. 12' 1' 1' LAYER OF INSULATION ACT❑RY INSTALLED IN /— ,00' END STANDOFF MEETS REQUIREMENTS CLEARANCE 1.O COMBUSTIBLE SURFACES. 26' 26' 13' CODE COMPLIANCE DEC 1 u 21ntu City of Tukwila BUILDING 0i1/1.cims RECEIVED NOV 182010 PERMIT CENTER REVISIONS DESCRIPTION DATE: A A A A 1 z U Buffet -17950 N_ SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com Tukwila, WA. DATE: 1 1/05/2010 DWG.#: 1164581 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET HO. - 0 i 0 III • yam ''�j ./ i 0 0 81— T 8i i 10' 10' 'I 10' i �,. 10' ► � •I . IS O % ° i1 �l ■° 6 , 0 \ 6 ■ I Field Cut 14' X 20' Exhaust I Riser I Field Cut 10 ; 14' X 20' 10 Exhaust I Riser vi ► r, Iii I-- io. ` H I-- 10' -I '1 L $ • J L J p — — — ri -11 cI ° i1, Ai U.L. Listed Screw In Compact Fluorescent Bulb h 9 j 6 ■ 0 6 0 O 1 w 10' ww =1 w =, W 10' I........I _ 8' I__ �i- % /ice . 8 1_ % /ice t i ° 11 %Iii . c I o 11 -- 12' 1' 27' 16' 6' 52' 16' 6' 13' 0,00'Nom, /13' 0.00' 0D 52' 16' 6' 27' PLAN VIEW — Hood #5 13' 0.00" LONG 5424EX1— PSP —FBSS NOTE! Additional hanging angles provided for hoods longer than 12 ft. 12' 1' 1' LAYER OF INSULATION ACT❑RY INSTALLED IN /— ,00' END STANDOFF MEETS REQUIREMENTS CLEARANCE 1.O COMBUSTIBLE SURFACES. 26' 26' 13' CODE COMPLIANCE DEC 1 u 21ntu City of Tukwila BUILDING 0i1/1.cims RECEIVED NOV 182010 PERMIT CENTER REVISIONS DESCRIPTION DATE: A A A A 1 z U Buffet -17950 N_ SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com Tukwila, WA. DATE: 1 1/05/2010 DWG.#: 1164581 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET HO. EXHAUST RISER HANGING ANGLE IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. EXHAUST RISER HANGING ANGLE IT IS THE RESPONSIBILITY OF THE ARCHITECT /OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 36' 4" 7ir DRAIN FULL PERIMETER GUTTER EQUIPMENT BY OTHERS 24' NOM, SECTION VIEW — MODEL 3624VHB —G id° 0. OP 4 r ae 36' A A DRAIN FULL PERIMETER GUTTER ,/ EQUIPMENT BY OTHERS 104' 80' AFF TYP, 24' NOM, SECTION VIEW — MODEL 3624VHB —G 104' 80' AFF TYP, FAN #6 DU12HFA - EXHAUST FAN (EX. DISH) 36' 18' 18' 18' 3' 0,00'Nor ./3' 0.00'0 PLAN VIEW — Hood #6 3' 0.00" LONG 3624VHB —G VHB —G Series Specification The VHB -G series heat /condensate hood is a single wall vent hood used in non - grease applications for- the removal of heat, vapor- etc, Hood shall have the size, shape and performance specified on the drawings. Construction shall be type 304 stainless steel with a #3 or #4 polish where exposed, Hood shall have a full perimeter gutter with a 1/2' ❑D Bolt thread drain connection, Hood shall be wall or island type with fully welded 10 gauge corner hanging angles. Corner hanging angles have a .625 x 1.500 slot pre - punched at the factory, allowing hanging rods to be used for quick and safe installations. Hanging rod and connection is provided by and installed by others. The hood manufacturer shall supply complete submittal drawings including hood section views(s) and hood plan view(s). These drawings must be made available to the engineer, architect and owner for their use in construction, operation and maintenance. Exhaust duct collar to be 4' high with 1' flanges. Duct sizes, CFM and static pressure requirements shall be as shown on the drawings. Hood shall be recognized by NSF. 36' 18' -- 10' 30' 5' 0,00'Norm, /5' 0.00'❑ 30' PLAN VIEW — Hood #7 5' 0.00" LONG 3624VHB —G FAN #7 DU30HFA - EXHAUST FAN (EX. DISH) FEATURES: - ROOF MOUNTED FANS - UL705 - VARIABLE SPEED CONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTI ❑N (SINGLE PHASE) OPTIONS SCR -12 BIRD SCREEN I 12 -BDD DAMPER FEATURES: - ROOF MOUNTED FANS - UL705 - VARIABLE SPEED CONTROL - INTERNAL WIRING - WEATHERPROOF DISCONNECT - THERMAL OVERLOAD PROTECTION (SINGLE PHASE) OPTIONS SCR -11 BIRD SCREEN I 15 -BDD DAMPER 20" 20 GAUGE STEEL C❑NSTRUCTI ❑N 13 - \ ROOF OPENING 13 DIMENSIONS COD WEVV�p POF? COMPLIANCE AD [Pnv ELF:(; I u 2u,ti City of Tukwila BUILDING DIVISION 20' 20 GAUGE STEEL C❑NSTRUCTI ❑N \ / 16 16 \ �/ ROOF OPENING DIMENSIONS RECEIVED NOV 18 2010 PERMIT CENTER REVISIONS DESCRIPTION DATE: 0 0 0 1 SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com U 0 Bu -F-Fet -17950 N 3 DATE: 9/20/2010 DWG. #: 1164581 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET NO. 9 EXHAUST FAN INFORMATION FAN UNIT NO, FAN UNIT MODEL # MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS,) 1 EABDU20 EABDU20 EX, SYSTEM # 1 3300 1.000 911 1,500 3 208 4,7 178,31 3 EABDU24 EABDU24 EX. SYSTEM # 2 WALL 4400 1,300 840 3.000 3 208 9.5 247.43 4 EABDU24 EABDU24 EX. SYSTEM # 2 5850 1.500 989 5,000 3 208 14.1 260,43 6 EADU12H EADU12H EX, DISH 450 0.300 1368 0.180 1 115 2.0 38.25 7 EADU3OH EADU3OH EX, DISH 750 0.325 1240 0.250 1 115 4.0 56.99 FAN ❑PTI ❑N (Qty. - Descr,) 1 1 - Grease Box GRAVITY DAMPER 1 - Extra Set of Belts GRAVITY DAMPER 1 - Hinge Kit - Ships Loose for Curb Supplied by Others 2 1 UNIT FAN UNIT MODEL # BLOWER H ❑USING TAG CFM S.P. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) NO, 1 - Grease Box 3 1 - Extra Set of Belts 1 - Hinge Kit (HD)- Ships Loose for Curb Supplied by Others 5 1 - Extra Set of Belts 4 2 EA -A4 -920 920 A4 MAU SYSTEM # 1 8910 1.000 575 5,000 3 208 14.1 983.18 5 EA -A4 -920 920 A4 MAU SYSTEM # 2 9225 1.000 583 5.000 3 208 14.1 983.18 TIONS FAN UNIT NO, ❑PTI ❑N (Qty. - Descr,) 1 1 - Grease Box GRAVITY DAMPER 1 - Extra Set of Belts GRAVITY DAMPER 1 - Hinge Kit - Ships Loose for Curb Supplied by Others 2 1 - Extra Set of' Belts 1 - Motorized Backdraft Damper for Size 4 Housing 3 1 - Grease Box 2 1 - Extra Set of Belts 1 - Hinge Kit (HD)- Ships Loose for Curb Supplied by Others 4 1 - Grease Box 3 1 - Extra Set of Belts 1 - Hinge Kit (HD)- Ships Loose for Curb Supplied by Others 5 1 - Extra Set of Belts 4 1 - Motorized Backdraft Damper for Size 4 Housing 6 1 - SCR -12 Bird Screen 1 - I 12 -BDD Damper 7 1 - SCR -11 Bird Screen 1 - I 15 -BDD Damper FAN UNIT NO, FAN UNIT TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 EX, SYSTEM # 1 2 MAU SYSTEM # 1 YES 3 EX, SYSTEM # 2 WALL 4 EX. SYSTEM # 2 5 MAU SYSTEM # 2 YES 6 EX. DISH 7 EX, DISH FAQ ii (04 - EXHAUST FAN (EX. SYSTEM # 1) 38 7/8 3 EACH TYPICAL DESIGN ) 33 3/8 } 18 21 24 28 29 1/2 GREASE DRAIN J 42 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FAN #3 U1-4k p, - EXHAUST FAN (EX. SYSTEM # 2 WALL) 43 3/8 37 1/2 } 23 7/8 26 7/8 28 33 30 5/8 GREASE DRAIN 53 3/4 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FAN #4 43 041.1.t. EXHAUST FAN (EX, SYSTEM # 2) 37 1/2 43 3/8 } 30 5/8 IIMEM GREASE DRAIN 23 7/8 26 7/8 28 33 53 3/4 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) FEATURES! - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300'F (149°C) - GREASE CLASSIFICATI ❑N TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300'F (149'C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITH ❑UT ANY DETERI ❑RATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION, ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316°C) FOR A PERI ❑D OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION, OPTIONS GREASE BOX EXTRA SET OF BELTS FEATURES! - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300°F (149'C) - GREASE CLASSIFICATI ❑N TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149'C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITH ❑UT ANY DETERI ❑RATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION, ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316'C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION, OPTIONS GREASE BOX EXTRA SET OF BELTS FEATURES! - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300'F (149'C) - GREASE CLASSIFICATI ❑N TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION, ABNORMAL FLARE -UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316°C) FOR A PERI ❑D OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION, OPTI ❑NS GREASE BOX EXTRA SET OF BELTS 20' 26 1/2' 426 1/2' 1111111v 4/ VENTED CURB 20 GAUGE STEEL C❑NSTRUCTI ❑N 3' FLANGE 24 24 �/ 1/2' 31 1/2' 28 ROOF OPENING DIMENSIONS REVIEW1 [) FOR CODE COMPLIANCE mmnum [[ , ( il...i, U L� i , City of Tukwila BUILDING DIVISinro VENTED CURB 20 GAUGE STEEL C❑NSTRUCTI ❑N 3' FLANGE ROOF OPENING DIMENSI ❑NS 31 1/2' 31 1/2' 20' VENTED CURB 20 GAUGE STEEL CONSTRUCTION 3' FLANGE 28 ROOF OPENING DIMENSI ❑NS RECEIVED NOV 18 2010 PERMIT CENTER REVISIONS DESCRIPTION DATE: A 0 A 0 1 c z U SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com 0 Buff et -17950 N_ Tukwila, WA. DATE: 11/05/2010 DWG-#: 1164581 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET MO. LIFTING LUG 5 1/4" EQUIPMENT CURB FAN #2 A4 -920 - SUPPLY FAN (MAU SYSTEM # 1) 1. UNTEMPERED SUPPLY UNIT WITH 20' BLOWER. IN SIZE #4 HOUSING 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. EXTRA SET OF V- BELTS. ONLY TO BE ORDERED AS FAN OPTION AT TIME FAN IS ORDERED, 5, MOTORIZED BACK DRAFT DAMPER 34' X 36 ", STANDARD GALVANIZED CONSTRUCTI ❑N, 1 1/4' REAR FLANGE, WITH H- 2000A/8 MOTOR, WALL SUPPLY MOUNT, FOR SIZE 4 UNTEMPERED FAN H ❑USING (5194) 48 7/16" 0 00 42" 20" ROOF OPENING 2" SMALLER THEN CURB DIMENSION. BLOWER DISCHARGE CURB 1 1/8" 24 7/8" 8 9/16' 51 3/8" T 0 0 0 24 7/8" FLEX CONDUIT FOR FIELD WIRING 64 3/16' J AIRFLOW BLOWER/MOTOR ACCESS DOOR 24' SERVICE CLEARANCE REQ. SERVICE -\. DISCONNECT SWITCH 42" LIFTING LUG 5 1/4" EQUIPMENT CURB 48 7/16' 0 00 42" 20" ROOF OPENING 2' SMALLER THEN CURB DIMENSION, CURB ASSEMBLIES N❑' FAON N ITEM SIZE 2 # 2 Curb 42.000 "W x 42,000 "L x 20.000 "H 5 # 5 Curb 42.000'W x 42.000 1L x 20.000 "H FAN #5 A4 -920 - SUPPLY FAN (MAU SYSTEM # 2) 1. UNTEMPERED SUPPLY UNIT WITH 20' BLOWER IN SIZE #4 HOUSING 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. EXTRA SET OF V- BELTS, ONLY TO BE ORDERED AS FAN OPTION AT TIME FAN IS ORDERED, 5. MOTORIZED BACK DRAFT DAMPER 34" X 36 ", STANDARD GALVANIZED CONSTRUCTION, 1 1/4' REAR FLANGE, WITH H- 2000A/8 MOTOR, WALL SUPPLY MOUNT, FOR SIZE 4 UNTEMPERED FAN HOUSING (5194) BLOWER DISCHARGE CURB -i 1 1/8' 24 7/8" 8 9/16' 51 3/8' 0 0 0 24 7/8" FLEX CONDUIT FOR FIELD WIRING 64 3/16" SERVICE DISCONNECT SWITCH AIRFLOW 1F...... BLOWER /MOTOR ACCESS DOOR 24' SERVICE CLEARANCE REQ, COD V /Ew,zl) FOR E COMPLIANCE :;' 0 2M City o of Tukwila BUILDING niuminit► 42" RECEIVED NOV 18 2010 PERMIT CENTER REVISIONS DESCRIPTION DATE: A 0 • 1 U Buf'f'et -17950 N_ S co co r-i co Tukwila, WA. E O U 2 a) U SEATTLE OFFICE 2804 GRAND AVE., SUITE 303, EVERETT, WA, 98204 PHONE: (425) 212 -5996 FAX: (425) 212 -5998 EMAIL: reg85 @captiveaire.com DATE: 9/20/2010 DWG. #: 1164581 DRAWN BY: SCALE: 1/16 MASTER DRAWING SHEET NO. AO