HomeMy WebLinkAboutPermit M10-167 - BOEING #9-99BOEING #9 -99 9725 EAST MARGINAL wys M10 -167 Parcel No.: Address: City otiI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT 0003400018 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9 -99 Permit Number: Issue Date: Permit Expires On: M10 -167 04/13/2011 10/10/2011 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 JOHN S MURDOCH PO BOX 3707 M/C 89 -14 , SEATTLE WA 98124 JOHN.S.MURDOCH@BOEING.COM Phone: 253 657 -0868 BOEING COMPANY, THE Phone: 312 544 -2535 Address: 100 N RIVERSIDE, M/C 5003 -4027 , CHICAGO IL 60606 -1596 Contractor License No: BOEINC *294ML Expiration Date: 01/18/2013 DESCRIPTION OF WORK: REPLACE THREE ROOFTOP AIR HANDLING UNITS IN-KIND. INSTALL OR MODIFY AIR DISTRIBUTION DUCTWORK. Value of Mechanical: 250,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $2,847.06 International Mechanical Code Edition: 2009 Date: k 3 I I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting •f this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio I.I the pe 'ormance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of thi . rmit. Signature Print N 214i4t-7?t s /i7 itdapeafr Date: /43 *fUli L-r✓/ figg0/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M10 -167 Printed: 04 -13 -2011 PERMIT CONDITIONS Permit No. M 10 -167 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this doc: IMC -4/10 M10 -167 Printed: 04 -13 -2011 project. • • 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M10 -167 Printed: 04 -13 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.atukwila.wa.us Mechanical Permit No. Project No. (-i or o ice use on MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** King Co Assessor's Tax No.: COO V40 l hi Site Address: 9725 East Marginal Way Tenant Name: The Boeing Company Property Owners Name: The Boeing Company - Attn. John S. Murdoch Mailing Address: P.O. Box 3707 M/C 89 -14 Suite Number: 9 -941 Floor: Roof New Tenant: ❑ Yes m .. No Seattle WA 98124 Zip City State CONTACT PERSON —who do we contact hen yo o be issued Name: John S. Murdoch Mailing Address: Same as Above Day Telephone: (253) 657 -0868 E -Mail Address: john.s.murdoch @boeing.com City State Fax Number: (253) 657 -0858 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Same As Above Mailing Address: City Contact Person: E -Mail Address: Contractor Registration Number: BOEINC*294ML State Zip Day Telephone: Fax Number: Expiration Date: 01/14/2011 ARCHITECT OF RECORD — All plan must be stamped by Company Name: Same As Above Mailing Address: city Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD — All plans must be stamped by engineer d Company Name: Same as Above Mailing Address: Contact Person: Brian Harr E -Mail Address: brian.p.harr @boeing.com I l :Applications \Poets- Applications On Line. 2010 Applications \7 -2010 - Mechanical Pennit Application.doc Revised: 7 -2010 bh City State Day Telephone: (206) 550 -0397 Fax Number: (206) 660 -0861 Zip Page I of 2 Valuation of project (contractor's bid price): $ 250,000 Scope of work (please provide detailed information): Replace three rooftop air handling units in -kind. Use: Residential: New Commercial: New Fuel Type: Electric m Gas Replacement Replacement m Other: Steam from gas -fired central plant Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm 3 fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall /floor mounted heater ventilation system wood /gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat /refrig /cooling system Incinerator — domestic other mechanical equipment MP air handling unit <10,000 cfm incinerator — comm /ind PERMIT APPLICATION NOTES Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJU I BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Poi 91r, C hi, F rr Print Name' John S. Murdoch - The Boeing Company Day Telephone: (253) 657 -0868 BUILDIN Signatur �T�H RI ED AGENT: Date: t fotleM : Mailing Address: P.O. Box 3707 M/C 89 -14 Seattle WA 98124 City Date Application Accepted: { (74W State Zip Date Application Expires: Staff Initials: t P. Applications \Forts- Applications On Line\2010 Applications \7 -2010 - Mechanical Penh ot Application.doc Revised: 7 -2010 bh Page 2 of 2 ill 0 C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0003400018 Permit Number: M10 -167 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 12/01/2010 Applicant: BOEING #9 -99 Issue Date: Receipt No.: R10 -02409 Initials: JEM User ID: 1165 Payment Amount: $2,847.06 Payment Date: 12/01/2010 03:23 PM Balance: $0.00 Payee: BOEING #000.239.103 TRANSACTION LIST: Type Method Descriptio Amount Payment Other Authorization No. ACCOUNT ITEM LIST: Description 2,847.06 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 PLAN CHECK - NONRES 000.345.830 Total: $2,847.06 2,277.65 569.41 doc: Receipt -06 Printed: 12 -01 -2010 • y • :INSPECTION RECORD Retain a copy with permit INSPECTION NO. .: PERMIT NO. .CITY'OF ",TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 ‘ • • Permit Inspection Re juest Line (206) 431 -2451 • • • • Project r, " l Type f InspeS�rion: .4 • U�' �)L.- 1 r'J Address . 5-7 7t' '1' : ,I�A,,.,i�L Date Called: 11. i, ,. J ' ;:'; Special Instructions: '• • / • Date Wanted:. a.m. p.m. Requester: Phone No: . ) ?/". •fApproved per applicable codes. OCorrections required prior to approval. COMMENTS: -- . ) ?/". n . Inspector: Ai Date: i(— r'1—(! .0 REINSPECTION.FEE REQUIRED. Prior to next inspection, fee must be paid at 6300.Soiithcenter Blvd.. Suite 100. Call to schedule reinspection. 7;.*. TS "' _ INSPECTION RECORD. Retain a copy with permit INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1 " Proj `� Type Inspection: `�L ,.... Add ess:2 Date Called •.• Special Instructions: I CO %Z ` V . Date Wanted: _ (/ �- 1 Requester: S r: R A/ l Phone! No: l5 5 Q --" O 3 q / Approved per applicable codes. Corrections required prior to approval. COMMENTS: (14 ez24 n r 1,1.jd, XTiJ - -''£iLNDi SLijtf ' S' tnJ• /6 L./ i e - ( ., lu (z..l3 R J o-F 1--bp uer u,' LA-3�L. n )c-, or (7--; i1 L . (D c Mt h)r R..2 Asi, e <Y 0 N A .1Z A.f ( V^, 'Ts 1vut seein f JO t r 1 totA/3 /H( U^ 5 StJ1 6430A, Ins • ector: Date _ 262 REINSPECTION FEE REQUIRED. Prior to next inspection. fee Must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • 2_ INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /4116 - /6 7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT d 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: t(3‘...,11 9 _ f le Type of Inspection: �^ r /44 . - .4 A:-..--- J^' 1.e., -! Addres's :- 723 6 m wy 5 • Suite #: Contact Person: L -,-a,, 11.01---,— Special Instructions: Phone No.: 20,- r -rm - e'3, 7 Approved per applicable codes... Corrections required prior to approval. COMMENTS: dSprinklers: H rs.: Fire Alarm: Hoof& & Duct: Monitor: PI-Fire: ( 44.4e/ 0..,,,f ,4 ,06 ..d.. viz. 1,•. rf . ,,,, ,,i•• 4 Needs Shift Inspection: • dSprinklers: H rs.: Fire Alarm: Hoof& & Duct: Monitor: PI-Fire: Permits: Occupancy Type: . -••.:• Inspector: �� $1 Date: it j/7/# H rs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: I State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 S INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS tl CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: (3 0.e, ''S C, _ I q Type of Inspection: Ate G-1 FA- Address: ci 7). 5 C c,)-NM4)- IA y S • Suite #: , •' .. Contact Person: 'Sr :C9 4'.% hcir✓ Special Iran ructions: Pre -Fire: . Phone No.: , )oL -STD -O3q - Approved per applicable codes. Corrections required prior to approval. COMMENTS:, Sprinklers: Fire Alarm: I. No prr - r erf f t .-4-. ((Z e. 1--e Pre -Fire: . 7t . ,ii 4 t i ro)-Rr vi, 45 '.`edi - -1':: ., /VV -� - Nee A A44 e c L g ; 6C V pl i -1- 4 s1e� - i • Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: . Permits: Occupancy Type: . Inspector: Awl _ f I Date: 7_,,)- (. -11 Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule'a reinspection. Billing Address Po r I Company Name: 13O M7 C . Address: !� ,i 70 L /)-14.44- Attn: City: Seel-Pie Word /Inspection Record • Form.Doc State: 4/A- 6/11/10 Zip: 5e/1 -.4..a7 T.F.D. Form F.P. 113 • • •• G • • • • • • 04 -01 -2011 0 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JOHN S MURDOCH PO BOX 3707 M/C 89 -14 SEATTLE WA 98124 RE: Permit Application No. M10 -167 9725 EAST MARGINAL WY S TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 12/01/2010, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 05/30/2011. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, 1,21k' '-,L Bill Rambo Permit Technician File: Permit File No. M10 -167 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 4 K - -- PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -167 DATE: 12/01/10 PROJECT NAME: BOEING #9 -99 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: ..41 +'l 411/\ 410(k_ �v Iding�D 'vision vi! re Prevention • Public Works ❑ Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 121 Comments: Incomplete DUE DATE: 12/02/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Building Please Route'{ Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/30/10 Approved ❑ Approved with Conditions 55 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Prater Friendly Page S General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BOEING COMPANY, THE 3125442535 100 N Riverside M/C 5003 -4027 Chicago IL 606061596 Out Of State Corporation UBI No. 178005030 Status Active License No. BOEINC•294ML License Type Construction Contractor Effective Date 7/13/1971 Expiration Date 1/18/2013 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date SHRONTZ, F A Cancel Date 01/01/1980 Amount CONDIT, P M 23 01/01/1980 HDOG25520051 GIVAN, B E 10/01/2011 01/01/1980 WOODARD, R B 09/30/2010 01/01/1980 ACE AMERICAN INS CO CRUZE, D D 10/01/2009 01/01/1980 KING, C G $10,000,000.00 01/01/1980 21 BEIGHLE, D P HD0G23732841 A 01/01/1980 10/01/2009 COLLINS, T J 01/01/1980 09 /26/2008 BUDINICH, T M ACE AMERICAN INS CO 01/01/1980 10/01/2006 READ, PAUL Secretary 01/01/2001 $5,000,000.00 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FEDERAL INS CO 81312466 01/01/2002 Until Cancelled $12,000.00 01/14/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 23 ACE AMERICAN INS CO HDOG25520051 10/01/2010 10/01/2011 $10,000,000.00 09/30/2010 22 ACE AMERICAN INS CO HDOG24934780 10/01/2009 10/01/2010 $10,000,000.00 09/22/2009 21 ACE AMERICAN INS CO HD0G23732841 A 10/01/2007 10/01/2009 $5,000,000.00 09 /26/2008 20 ACE AMERICAN INS CO HDOG21734378 10/01/2006 10/01/2007 $5,000,000.00 09/25/2006 19 ACE AMERICAN INS CO HDOG21731869 10/01/2005 10/01/2006 $5,000,000.00 09/26/2005 18 ACE AMERICAN INS CO HDOG21731869 10/01 /2003 10/01/2005 $25,000,000.00 11/10/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period http s : // fortress. wa. g ov /l ni/bb ip /Pri nt. aspx 04/13/2011 VCI \ITY MAP n 14-01 7 -127 FROM DOWNTOWN SEATTLE r� 900 P \P c)E�� 99 EXIT 158 EXIT 157 EXIT 157 i 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE - TACOMA AIRPORT 599 TUKWILA DEVELOPVE\TAL CE \TER FROM KENT & AUBURN NO SCALE 90 9 THE BOEING COMPANY 9 -99 BUILDING REPLACE ROOFTOP AIR HANDLING UNITS JOB NUMBERS. 55776005 & 57770701 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA VAP BUILDI\G AD:RESS: 9725 EAST VARGI\AL WAY S3,T TJ<WILA, WASHI \GTO\ PROJECT SITE B.,IL I \G 9 -99 LOCATIO\ NO SCALE SEPARATE PERMIT REQUIRED FOR: 13 GNP City of 7'ukwkt BUILDING DIVISION REVISIONS NO Nltenges shall be do amam to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. GE \ERAL \DYES 1. WORK IS SCHEDULED TO BE PERFORMED BY BOEING IN -HOUSE CONSTRUCTION CREW. 2. CONSTRUCTION SET OF DOCUMENTS MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 3. GCU TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE COMMENCING WORK. 4. NOTIFY BRIAN HARR (206) 550 -0397, IF EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 5. COORDINATE WORK WITH OTHER CRAFTS. 6. RETURN COMPLETE CONSTRUCTION "AS- BUILT" REDLINED DRAWINGS TO BRIAN HARR (206) 550 -0397 AFTER COMPLETION OF THIS CONSTRUCTION. 7. CONTRACTOR TO MAINTAIN CONSTRUCTION AREAS IN CLEAN, ORGANIZED SAFE CONDITON. MAINTAIN "CONSTRUCTION ZONE" THAT ALLOWS ACCESS TO OTHER OPERATING AREAS KEEP DUST & DEBRIS CONFINED WITHIN THE CONSTRUCTION SITE. PROJECT CHE <LST CHECK BOX SI THESE DRAWINGS CONFORM TO THE 2006 I.B.C., I.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. M ROOMS LABELED PER OCCUPANCY PER I.B.C. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ® NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: ❑ 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS 1=15 SETS OF CONST. SPECIFICATIONS ❑ 2. TENANT IMPROVEMENT (NON- STRUCTURAL): ❑ 4 SETS OF ARCHITECTURAL DRAWINGS ❑ 4 SETS OF STANDARD DETAILS ❑ 4 SETS OF ENERGY CALCULATIONS ❑ 4 SETS OF CONSTRUCTION SPECIFICATIONS ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. • 4. MECHANICAL, 4 COMPLETE SETS (SUBMITTED SEPARATELY) ❑ 5. FIRE PROTECTION /SPRINKLERS, 3 COMPLETE SETS (SUBMITTED SEPARATELY) ® BRIEF PROJECT NARRATIVE: REPLACE EXISTING ROOFTOP UNIT HEATERS. MODIFY ROOF OPENINGS, CURB, AND INSTALL REPLACEMENT PACKAGED ROOFTOP AIR HANDLING UNITS. CONNECT NEW UNITS TO ELECTRICAL, CMCS CONTROL, STEAM, CONDENSATE, AND DRY PIPE SPRINKLER SYSTEM. INSTALL 2 SPRINKLERS IN EACH UNIT. INSTALL OR MODIFY AIR DISTRIBUTION DUCTWORK. SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ISSUE FOR PERMIT 57770701 HARR RWS 07/30/08 A ISSUE FOR CONTRACTOR BIDDING 57770701 HARR 10/22/08 B REISSUE FOR MECHANICAL PERMIT 55776005 & 57770701 HARR 11/08/10 QiBOE /NG° C'- ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN E.DUARTE CHECKED DATE 09.16.93 FILE COPY Permit Flo. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize tht: violati. of anA adopted code or ordinance. Receipt of appro L1k1 :I ►.., , ; :. IS I e wig dg ; Caaltfl'l? By oViLic.414. Ph. ..1 /3 J,, City Of"lUkwiia BUILDING DIVISION DRAWI \G I \DEX DRAWING N0. SHEET TITLE REVISION N0. DATE ARCH TECTURAL 9 -99 -AO TITLE SHEET B 11/08/10 VECHA\ICAL 9 -99 -M2 EQUIPMENT SCHEDULE RV. B,D, &E 11/08/10 9- 99 -RFM10 ROOF LEVEL PARTIAL HVAC PLAN REV. D &E 11/08/10 9- 99 -HBM10 HIGH BAY HVAC PARTIAL PLAN REV. D &E 11/08/10 9- 99 -HBM60 HIGH BAY HVAC PIPING PARTIAL PLAN REV. G 08/07/08 9- 99 -3M12 HVAC PLAN REV. B 03/17/09 9- 99 -HBM62 HIGH BAY PARTIAL PLAN HVAC PIPING REV. B 06/08/09 9- 99 -M500 > -` SECTIONS AND DETAILS REV. E 03/17/09 9- 99 -M548 GSECTIONS AND DETAILS REV. A 06/06/08 REVIEWED FOR CODE COMPLIANCE PP fVED DEC 15 2010 AS "t. City of Tukwila BUILDING DIVISION CODE SUV V ARY LAND USE CODE BUILDING CODES TUKWILA 00o9' -- 1"hF.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUPS B AND F -2 (OFFICE AND FACTORY) TYPE II, NON- COMBUSTIBLE OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS FIRST FLOOR SECOND FLOOR PENTHOUSE BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE 59,292 67,799 59,292 4,082 4,425 44 FT. crtvISCOMu► DEC Q 12010 PERMIT CENTER 'oltv1 0 401111■ 3 (1 STORY IN PROJECT AREA) NO CHANGES BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 3 SUBTITLE TITLE SHEET CURRENT REVISION 57770701 SYMBOL DATE 11/08/10 APPROVED BY DEPT. DATE ENGINEER HARR CHECKED 07/14/08 APPROVED APPROVED TITLE REPLACE AIR HANDLING UNIT BUIL 3I \G 9 99 ARCHITECTURAL MASTER COL. A -G/1 -4 D.0 SHEET AC JOB NO. COMP NO. DWG NO. 9 -99 -AO C1891 A: 10/22/08 10:15 FAN SCHEDULE CONTROL VALVE SCHEDULE AREA SERVED LOCATION EQUIPMENT SERVED ROOFTOP AIR HANDLING UNIT SCHEDULE FLOW Cv END CONNECTION BODY (CAST) UNIT NO LOCATION SUPPLY FAN SECTION HEATING COIL FILTERS EQUIPMENT WEIGHT (LBS) MANUFACTURER CURB WEIGHT (LBS) UNIT DIMENSIONS DOWN DISCHARGE AIR DUCT SIZE REMARKS STEAM 810 # /HR TYPE TOTAL CFM MINIMUM OA CFM RPM TSP (IN. WG) ESP (IN. WG) MOTOR CFM STEAM PRESS LBS/ HR EDB ° F LDB • F TOTAL MBH L IN, W IN. H IN. QTY HP VOLTS PH AHRB2 ROOF CENT 16,500 1,650 609 2.19 1.00 1 15 460 3 16,500 30 PSIG 1017 40.0 92.9 945.93 8 -16 "X25" _ ►" 3,986.40 THREAD 384.30 138.25 97.00 63.50 31-1/8" X 31-1/4" OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, •' I1 • •, '• , , -I, - 4 11 °: CV -5 C -3 AHRD3 ROOF CENT 16,500 1,650 609 2.19 1.00 1 15 460 3 16,500 30 PSIG 1017 40.0 92.9 945.93 8 -16 "X25" 2 -20 "X25" 3,986.40 ELECT 384.30 138.25 97.00 63.50 31-1/8" X 31-1/4" OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB STEAM 844 # /HR 16 THREAD IRON • •O .51 .:• . • 4: CV -8 ROOF - ,,• . ,10 ! P ! • 40 4 92. • ; 2 -20 "X25" •. 98 ,� 30 PSI STEAM / 8 PSI DROP. TWO -WAY PROPORTIONAL ACTUATOR -, T -10 �� 2 - 0 • MI :, ',. . . .; ,.,�. HORIZONTAL STEAM COIL, FAN, AND CURB 15 100 -I •.� AHRB3 ROOF CENT 16,500 1,650 609 2.19 1.00 1 15 460 3 16,500 30 PSIG 1017 40.0 92.9 945.93 8 -16 "X25" _ S 3,986.40 15 384.30 138.25 97,00 63.50 31 -1/8" X 31 -1/4" OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, '0'..1 A . A, ,i „ , P 11: AHRB1 ROOF CENT 16,500 1,650 608 2.18 1.00 1 15 460 3 16,500 30 PSIG 844 40.0 85 805 12 -20 "X20" 4 -20 "X25" 4316 392 142.75 97.00 63.50 31 -1/8" X 31 -1/4" OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB AHRF2 ROOF CENT 16,500 1,650 608 2.18 1.00 1 15 460 3 16,500 30 PSIG 844 40.0 85 805 12 -20 "X20" 4 -20 "X25" 4316 392 142.75 97.00 63.50 31-1/8" X 31-1/4" OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB - - - A A A A A A A A A A A A A. A A A A A A A A A /%, A A A FAN SCHEDULE CONTROL VALVE SCHEDULE AREA SERVED LOCATION EQUIPMENT SERVED SERVICE FLOW Cv END CONNECTION BODY (CAST) SIZE ACTUATOR BASIS OF DESIGN REMARKS TAG LOCATION MANUFACTURER MODEL CV -1 HIGH BAY AHRB2 STEAM 810 # /HR 16 THREAD IRON 1 1/4" ELECT BELIMO G232S - NVF24 -MFT -E 30 PSI STEAM / 8 PSI DROP. TWO- POSITION NORMALLY CLOSED ACTUATOR CV -2 HIGH BAY AHRD3 STEAM 810 #'HR 16 THREAD IRON 1 1/4" ELECT BELIMO G232S - NVF24 -MFT -E 30 PSI STEAM / 8 PSI DROP. TWO- POSITION NORMALLY CLOSED ACTUATOR CV -3 HIGH BAY AHRD2 STEAM 810 # /HR 16 THREAD IRON 1 1/4" ELECT BELIMO G232S - NVF24 -MFT -E 30 PSI STEAM / 8 PSI DROP. TWO- POSITION NORMALLY CLOSED ACTUATOR CV -4 HIGH BAY AHRB3 STEAM 810 # /HR 16 THREAD IRON 1 1/4" ELECT BELIMO G232S - NVF24 -MFT -E 30 PSI STEAM / 8 PSI DROP. TWO- POSITION NORMALLY CLOSED ACTUATOR CV -5 C -3 FC -1 CHILLED WTR 3 GPM 1.9 THREAD BRASS 1/2" ELECT BELIMO B210- LF24 -SR US FURNISHED ON OMEGA CONTRACT FOR PLATFORM CV -6 C -3 FC -2 CHILLED WTR 7 GPM 4.7 THREAD BRASS 1/2" ELECT BELIMO B213- LF24 -SR US FURNISHED ON ATS CONTRACT FOR RF ROOM CV -7 ROOF AHRB1 STEAM 844 # /HR 16 THREAD IRON 1 1/4" ELECT BELIMO G232S - NVF24 -MFT -E 30 PSI STEAM / 8 PSI DROP. TWO -WAY PROPORTIONAL ACTUATOR CV -8 ROOF AHRF2 STEAM 844 # /HR 16 THREAD IRON 1 1/4" ELECT BELIMO G232S - NVF24 -MFT -E 30 PSI STEAM / 8 PSI DROP. TWO -WAY PROPORTIONAL ACTUATOR FLOAT & THERMOSTATIC T -10 AHRB1 2 HIGH BAY FAN SCHEDULE UNIT NO. AREA SERVED LOCATION CFM ESP IN WG OV FPM FAN MOTOR UNIT WGT FAN 1 TYPE WHEEL TYPE BASES OF DESIGN REMARKS BHP RPM HP VOLTS PH EFRE2 WELD SHOP HIGHBAY 30,000 1 2338 12.63 820 15 460 3 1350 ROOF PROP COOK 48 -SUB UPBLAST BELT DRIVE WITH CURB AND VFD C -3 1200 SARCO FT -30 FLOAT & THERMOSTATIC T -3 AHRD3 2 HIGH BAY 30 FIRST CO. HEATING & AIR 36SHW FURN. BY EMERALD AIR ON ATS CONTRACT FOR RF ROOM 1" SARCO FT -30 CHILLED WATER FAN /COIL UNIT SCHEDULE UNIT NO. AREA SERVED LOCATION CFM ESP IN WG OV FPM FAN MOTOR UNIT WGT MANUFACTURER MODEL REMARKS BHP RPM HP VOLTS PH FC -2 OFFICE C -3 550 510 650 1" 1/2 1/2 1/2 1/2 96.3 TRANE BCHC018A1 FURN, BY SHINN MECH ON OMEGA CONTRACT FOR PLATFORM FC 1 OFFICE C -3 1200 SARCO FT -30 FLOAT & THERMOSTATIC T -3 AHRD3 2 HIGH BAY 30 FIRST CO. HEATING & AIR 36SHW FURN. BY EMERALD AIR ON ATS CONTRACT FOR RF ROOM STEAM TRAP SCHEDULE TAG SERVES QUANTITY LOCATION PRESSURE OPERATING DESIGN LOAD ( # /HR) COLD START -UP LOAD ( # /HR) ' SIZE BASIS OF DESIGN REMARKS INLET (PSIG) OUTLET (PSIG) MFGR MODEL T -1 AHRB2 2 HIGH BAY 30 15 510 650 1" SARCO FT -30 FLOAT & THERMOSTATIC T -2 AHRB2 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC T -3 AHRD3 2 HIGH BAY 30 15 510 650 1" SARCO FT -30 FLOAT & THERMOSTATIC T -4 AHRD3 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC T -5 AHRD2 2 HIGH BAY 30 15 510 650 1" SARCO FT -30 FLOAT & THERMOSTATIC T -6 AHRD2 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC T -7 AHRB3 2 HIGH BAY 30 15 510 650 1" SARCO F7-30 FLOAT & THERMOSTATIC T -8 AHRB3 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC T -9 AHRB1 2 HIGH BAY 30 15 510 650 1" SARCO FT -30 FLOAT & THERMOSTATIC T -10 AHRB1 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC T -9 AHRF2 2 HIGH BAY 30 15 510 650 1" SARCO FT -30 FLOAT & THERMOSTATIC T -10 AHRF2 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR PERMIT /BID 534907 -03 COFFMAN 01.12.05 B INSTALL AHRB3 55776005 HARR RWS 08/22/06 C ADD 2 FAN /COIL UNITS 56739200 HARR RWS 12/10/07 D INSTALL AHRB1 57770701 HARR 06/06/08 E INSTALL AHRF2 3032/57770703 HARR RWS 03/17/09 � Q BOE /NG' h� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN NFH CHECKED ILI DATE 01.12.05 LE3E \D CE\ERAL \ or -S REFERE\CE DRAWI \GS CO\ STRUCTIO\ \OTES REVIEWED FOR CODE COMPLIANCE APDDIWFQ DEC 15 2010 City of Tukwila BUILDINR lnnSIlto M 01.12.05 SUBTITLE SCHEDULES CURRENT REVISION 557760/577707 SYMBO cmr�nu+ DEC 01 2010 PERMIT CENTER -DATE 11/08/10 APPROVED BY DEPT. DATE ENGINEER ILI 01.12.05 CHECKED APPROVED APPROVED TITLE BUILDING 9 -99 DEV. CENTER, WA SHEET M2 JOB NO DWG NO. 534907 -03 9 -99 -M2 COMP NO. CI891 A: 10/20/08 ( 3 STEAM AND CONDENSATE RETURN DOWN TFAM AND CONDFNSATF RETURN DOWN 0 0 25-0" CROSS BRACES BETWEEN TRUSSES - REF 1 1' -10 3/4" REF SUPPLY AIR PLENUM BELOW -' TRUSSES BELOW - REF AH RB 15-0" TYP, REF LL w 00 I 0 FLOOR PLA\ SCALE: 1/8 "= 1' -0" A M1M10 M531 1M10 HBM10 B M1M10 M537 1M10 HBM10 C M1M10 M534 1M10 HBM10 D M1M10 530 1M10 HBM10 M1M10 M532 1 M 10' HBM10 F OM 1M10� HBM10 UNIT HEATER UH -2 ABANDONED IN PLACE EXISTING VENT XI IN UNIT SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR PERMIT /BID 534907 -03 COFFMAN 01.12.05 8 REMOVE WING UNIT HEATER #1 55776005 HARR RWS 09/13/06 C INSTALL AHRB3 55776005 HARR RWS 09/15/06 D INSTALL AHRB1 57770701 HARR 07/30/08 E VALVE BOX MOVED TO WEST SIDE 57770701 HARR 08/07/08 pr,oE /iVG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN NFH CHECKED I LI DATE 01.12.05 01.12.05 SUBTITLE LEGE \' GE \ERAL \OTES REFERE \CE DRAM \ �S CO` STRUCTIO\ \OTES INSTALL AHRB1 ON TRANE FACTORY- FURNISHED ROOF CURB KIT. SEE STRUCT DWGS RFS10 AND S529 FOR DETAILS. FIELD VERIFY SO UNIT IS CENTERED BETWEEN ROOF TRUSSES. FIELD VERIFY SO DISCHARGE AIR PLENUM FITS BETWEEN EXISTING CROSS BRACES BETWEEN ROOF TRUSSES. LOCATE PLENUM CLOSE TO WEST TRUSS TO MAXIMIZE SPRINKLER HEAD CLEARANCE. ABANDON UNIT HEATER #2 IN PLACE. SEAL ALL OPENINGS IN UH -2 ENCLOSURE WITH GALVANIZED SHEET METAL. M 1 0 I 61 REVIEWED FOR CODE COMPLIANCE ApDRnVED DEC 15 20110 City of Tukwila BUILDING nIUISInW ROOF LEVEL PARTIAL HVAC L KEY PLAN SCALE: NONE CURRENT REVISION 57770701 SYMBOL A J &E DEC 01 2010 PERMIT CENTER DATE 11/08/10 APPROVED BY DEPT. DATE ENGINEER ILI 01.12.05 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 9 -99 COL. A -C/1 -4 DEV. CENTER, W SHEET RFM10 JOB NO. 57770701 COMP NO. DWG NO. 9- 99 -RFM 10 0 0 0 0 w w 0 / p r- r A RFM10 A RFM11 RFM12 KEY PLAN SCALE: NONE CURRENT REVISION 57770701 SYMBOL A J &E DEC 01 2010 PERMIT CENTER DATE 11/08/10 APPROVED BY DEPT. DATE ENGINEER ILI 01.12.05 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 9 -99 COL. A -C/1 -4 DEV. CENTER, W SHEET RFM10 JOB NO. 57770701 COMP NO. DWG NO. 9- 99 -RFM 10 0 0 0 0 w w 0 TRUSSES — REF CL OF TRUSS OPENINGS c3-) 60 "x24 "x13' -0" LONG PLENUM W/5 EA. 48x18 DIFFUfERS 3300 CFM EA, TITUS 122RS EFRAO3A HP 480V 3 —PHASE 44- \/ U V / ■ A / ■ I -OVAL- MAN —BARS ALL AROUND EF T 5' AFF HBM10 M500 311x31 UP TO AHRB2 60 "x24 "x13' -0" LONG PLENUM W/5 EA. 48x18 DIFFUSERS 3300 CFM EA. TITUS 122RS 24" DIA NECK TITUS XC -310 DIFFUSER — TYP FIRE BRANCH — EFRCO3A 10,000 CFM 3 HP 480V 3 —PHASE FLO3R PLA\ SCALE: 1 /8 " =1 '0" ■ I V II V II \I II \/ II VII I A II A II /'t II A II All ■ AH \RB2% TO EF -8 J AFF 68x26 Rc AIR UP /1 OUTLINE OF / I AHRB2 ON ROOF i" I i M1M10 M532 1M10 HBM10 M1M10 M533 1M10 HBM10 ROOF TRUSSES — REF w J U N M1M10 M531 1M10 HBM10 A M1M10 M534 1M10 HBM1i0 / / / / / / / i M1M10 M530 i 1M10� HBM10 / f 2500 CFM 24 DIA �q 600 CFM SUPPLY POINT OF CONNECTION z K AHU) ON ROOF JOIST SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A DRC RFI 114 11073702 LM THOMAS F VALVE BOX MOVED TO WEST SIDE 57770701 HARR 08/07/08 B ISSUE FOR PERMIT /BID 534907 -03 COFFMAN 01.12.05 C REMOVE UNIT HEATER #1 55776005 HARR RWS D INSTALL AHRB3 55776005 HARR RWS E INSTALL AHRB1 57770701 HARR 09/20/06 09/20/06 07/30/08 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN NFH CHECKED ILI 2500 C 24 DI DATE 01.12.05 01.12.05 B M1M10 M537 1M10 HBM10 t4t0-~Icv`7 SUBTITLE HIGH BAY PARTIAL PLAN HVAC DUCTWORK GE \ERAL \ TES REFERE\ CE DRAWI \GS CC\STRUCTO\ \CTES 1. MAINTAIN CLEARANCE ABOVE CRANE RAILS FOR BRIDGE CRANE. INSTALL SUPPLY AIR PLENUM WITH DIFFUSERS PER SECTION A ON DRAWING M500. 3. LOCATE AHU AND PLENUM ACCORDING TO DIMENSIONING NOTES ON RFM10. LOCATE PLENUM CLOSE TO WEST TRUSS TO MAXIMIZE SPRINKLER HEAD CLEARANCE. REVIEWED FOR CODE COMPLIANCE imbonvEn DEC 15 1U10 City of Tukwila BUILDING nivmminm n C HBM10 HBM11 HBM12 KEY PLAN SCALE: NONE CURRENT REVISION 57770701 SYMBOL E AMA DEC 012010 PERMIT CENTER DATE 11/08/10 APPROVED BY DEPT. DATE ENGINEER ILI 01.12.05 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 9 -99 COL. A -C/1 -4 DEV. CENTER, WA SHEET HBM10 JOB NO. 534907 -03 COMP NO. DWG NO. 9 -99 -HBM10 CI891 A: 10/22/08 I r I -OVAL- p. .4 I 46/24 60 "x24 "x13' -0" LONG PLENUM W/5 EA. 48x18 DIFFUSERS 3300 CFM EA. TITUS 122RS 24" DIA NECK TITUS XC -310 DIFFUSER — TYP FIRE BRANCH — EFRCO3A 10,000 CFM 3 HP 480V 3 —PHASE FLO3R PLA\ SCALE: 1 /8 " =1 '0" ■ I V II V II \I II \/ II VII I A II A II /'t II A II All ■ AH \RB2% TO EF -8 J AFF 68x26 Rc AIR UP /1 OUTLINE OF / I AHRB2 ON ROOF i" I i M1M10 M532 1M10 HBM10 M1M10 M533 1M10 HBM10 ROOF TRUSSES — REF w J U N M1M10 M531 1M10 HBM10 A M1M10 M534 1M10 HBM1i0 / / / / / / / i M1M10 M530 i 1M10� HBM10 / f 2500 CFM 24 DIA �q 600 CFM SUPPLY POINT OF CONNECTION z K AHU) ON ROOF JOIST SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A DRC RFI 114 11073702 LM THOMAS F VALVE BOX MOVED TO WEST SIDE 57770701 HARR 08/07/08 B ISSUE FOR PERMIT /BID 534907 -03 COFFMAN 01.12.05 C REMOVE UNIT HEATER #1 55776005 HARR RWS D INSTALL AHRB3 55776005 HARR RWS E INSTALL AHRB1 57770701 HARR 09/20/06 09/20/06 07/30/08 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN NFH CHECKED ILI 2500 C 24 DI DATE 01.12.05 01.12.05 B M1M10 M537 1M10 HBM10 t4t0-~Icv`7 SUBTITLE HIGH BAY PARTIAL PLAN HVAC DUCTWORK GE \ERAL \ TES REFERE\ CE DRAWI \GS CC\STRUCTO\ \CTES 1. MAINTAIN CLEARANCE ABOVE CRANE RAILS FOR BRIDGE CRANE. INSTALL SUPPLY AIR PLENUM WITH DIFFUSERS PER SECTION A ON DRAWING M500. 3. LOCATE AHU AND PLENUM ACCORDING TO DIMENSIONING NOTES ON RFM10. LOCATE PLENUM CLOSE TO WEST TRUSS TO MAXIMIZE SPRINKLER HEAD CLEARANCE. REVIEWED FOR CODE COMPLIANCE imbonvEn DEC 15 1U10 City of Tukwila BUILDING nivmminm n C HBM10 HBM11 HBM12 KEY PLAN SCALE: NONE CURRENT REVISION 57770701 SYMBOL E AMA DEC 012010 PERMIT CENTER DATE 11/08/10 APPROVED BY DEPT. DATE ENGINEER ILI 01.12.05 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 9 -99 COL. A -C/1 -4 DEV. CENTER, WA SHEET HBM10 JOB NO. 534907 -03 COMP NO. DWG NO. 9 -99 -HBM10 CI891 A: 10/22/08 90 GPM 2" CLWS 2 -1/2" CLWR C 1-1/4" ctws -& CLWR T 2 -1/2" CLWS 1,� 10,000 CFM \\,1/4 3 HP 480V 3 -PHASE 51/51 OPENING UP TO EF -7 / STEAM & CONDENSATE RETURN UP. SEE M500 FOR COIL PIPING DETAIL. 2 -1/2" CLWR 1-1/4" CLWS & CLWR 20 GPM Le- 2-1/2" CLWS 2" CLWR 2 -1/2" STEAM r0� T -8 2' -7" 2-1/2" CS & C __CROSS BRACES BETWEEN TRUSSES - REF 2 -1 2" LPS 3/4" L �� nnn� I V �� STEAM & CONDENSATE UP TO AHRF2 N. ROOF TRUSSES - REF 0 N- 1 -1/4" CONDENSATE F� I L - - - -� AH \RB3/ 2" CLWS 2 -1/2" CLWR EFRCO3A 10,000 CFM 3 HP 480V 3 -PHASE PENN MODEL LF60 .5" SP 1" CLWS AND CLWR 1" CLWS AND CLWR 2 -1/2" CLWS 3" CLWS & CLWR 2 -1 /2" CL IS ' STEAM 1 -1/4 "--\ 1-1/4" CLWS & CLWR 17( HBM60 AH L___— i \B2/ 2-1/2" CLWS & CLWR 1 -1/4" CONDENSATE 2-1/2" STEAM �- 2" CONDENSATE 3" CLWS M500 E M1M10 M53 1M10Thie H3M-10 A M1M10 M5 1M10 HBM10 M1M10 M533 1M10� HBM1O MAN -BARS ALL AROUND ABANDONED IN PLACE M1M10 1M10 HBM10 C M M1M10 M5 1M10 HBM10 PARTIAL P LA \ VIEW SCALE: 1/8"=1'0" 3 4 M1M 1 M1 0 D 0 HBM10 M5 0 1" CONDENSAIL 1 1/2" STEAM BARON/ ETRI1 DAMPER DIFF. 24" 0 2500 CFM (4 PLACES) i14I 26/14 ti 25/31 T -10 3 11 CLWS AHU ABANDONED 4 IN PLACE 58/25 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A RELOCATE HYD. SHOP B ISSUE FOR PERMIT /BID 13023222 MJS 534907 -03 COFFMAN RWS 06.11.04 01.12.05 F INSTALL AHRB1 G VALVE BOX MOVED TO WEST SIDE 57770701 HARR 57770701 HARR 07/30/08 08/07/08 C CHWS /R TO NEW A/C @ B -3 56629401 HARR RWS 06/16/06 D REMOVE UNIT HEATER #1 55776005 HARR RWS 09/20/06 E INSTALL AHRB3 55776005 HARR RWS 09/20/06 LBOE /NG° o� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN NFH CHECKED ILI ENGINEER ILI 3 CLWR 4" CLWS 4" CLWR CB' GE \ERAL \OTES SEQUENCE OF OPERATION UH -2 OCCUPIED MODE: THERMOSTAT CYCLES UNIT ON AND OF OPENS OSA DAMPER AND MODULATES CONTROL VALVE TO MAINTAIN SET POINT (65° F OCCUPIED AND 55° F UNOCCUPIED.) UNIT INTERLOCKED WITH SPRAY BOOTH FAN TO START, OPEN DAMPER AND MODULATE CONTROL VALVE TO MAINTAIN SET POINT WHEN SPRAY BOOTH STARTS. 2. COOLING WATER SUPPLY AND RETURN PIPING (CLWR AND CLWS) ABANDONED IN PLACE. 3. HEAT AND VENT: REPAIR UNIT HEATER (UH -2). DISCHARGE DOES NOT ROTATE AND THE CONTROL S EM ► D • H E POWER OR 4. 2-1/2" LPS: SCH 40 BLK STL PIPE, BUTT WELD FITTINGS, CLASS 150 FLANGES & VALVES. 5. 1-1/4" LPC: SCH 80 BLK STL PIPE, CLASS 150 SCREWED MI FITTINGS, CLASS 150 SCREWED BRONZE VALVES. 6. LPS & LPC INSULATION: 2" THICK FIBERGLASS & ALL SERVICE JACKET. CC SIR U CTO \ \OYES PHASE 1: INSTALL STEAM AND CONDENSATE PIPES THROUGH TRUSSES. TERMINATE WITH GLOBE VALVES WHERE SHOWN. SHUT DOWN LP STEAM IN MECHANICAL ROOM FOR FINAL TIE -IN. TEST. RESTART STEAM. COORDINATE INSULATION BY E. J. BARTELLS. PHASE 2: EXTEND LPS & LPC INTO ENCLOSURE ON SIDE OF NEW AHU AHRB1. INSTALL NEW VALVES, TRAPS, ETC. PER DETAIL 1 ON M -500. COORDINATE INSULATION BY E. J. BARTELLS. ABANDON EXISTING STEAM AND CONDENSATE PIPING TO UNIT HEATER #2. CLOSE ALL VALVES. FIELD VERIFY. ON NORTH /SOUTH RUN, FASTEN TO EACH TRUSS; ON EAST /WEST RUN, SUPPORT AT 7' -0" MAXIMUM INTERVALS. REFERE \CE DRAWI\ GS 109 - 099 - 4000 -M4 REVIEWED FOR CODE COMPLIANCE ADDronvEn DEC 15 nil City of Tukwila BUILDINP nivicInni SCALE: NONE 8CenD 8MLA DEC 0 7 2010 PERMIT CENTER DATE SUBTITLE 01.12.05 01.12.05 TITLE 01.12.05 CHECKED APPROVED APPROVED HIGH BAY PARTIAL PLAN HVAC PIPING MECHANICAL MASTER BUILDING 9 -99 COL. A -C/1 -4 CURRENT REVISION SYMBOL 57770701 G SHEET DATE 08/07/08 HBM60 JOB NO. 534907 -03 COMP NO. DEV. CENTER, WA DWG NO. 9 -99 -HBM60 C1891 A: 08/07/08 07:30 (4, 3\ TITUS MODEL #DL DRUM LOUVER, 60" X 15" WITH OPPOSED BLADE DAMPER, 5000 CFM (TYP3) 3610 x 90° ELL WITH CLR = 3 Pf 20 "0 DUCT 480 V PLUG IN BUS DUCT (EXIST.) X20" X 30" 1-\■ FCR ROOiv A\ VECHA\ICAL 3iCTWOR< ECLIIPvE\T, SEE :WG c —9S V549 H 46" 30" 60 "X I, 31 36"0 DISCHARGE W/45' CUT & BIRD SCREEN TRANE MODEL #MCCA030 "CLIMATEMASTER" CENTRAL STATION AHU 86" x 31" INTAKE HO WITH :IRD SCREEN SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ABLATIVE COATING AREA B REPLACE UH #5 W/ AHRF2 757566 -07 3032/57770703 KGP HARR RWS RWS 12/05/96 03/17/09 Q� BOE /NG° tr� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN PENROD CHECKED DATE 12/5/96 'UoiI6'1 LEGEND: GENERAL NOTES: TRANE MODEL #MCCA030 "CLIMATEMASTER" CENTRAL AIR HANDLING UNIT IN THE FOLLOWING ORDER, RETURN FAN (7.5 HP), ECONOMIZER MODULE, AIR MIXING MODULE WITH 2" FILTER, BAG FILTER MODULE WITH 95% FILTERS, INTERNAL FACE AND BYPASS MODULE, (2) STEAM COIL MODULES, 40" LONG BLANK MODULE, 15.5" BLANK MODULE, AND THE SUPPLY AIR FAN (25 HP). CONSTRUCTION NOTES: REMOVE EXISTING UNIT HEATER #5. INSTALL IN ITS PLACE NEW TRANE UNIT AHRF2 WITH TRANE- SUPPLIED CURB KIT. MODIFY ROOF AS REQUIRED. SEE RFS12. CONNECT EXISTING SUPPLY AIR DUCT SYSTEM TO NEW AIR HANDLER AHRF2. SEE ALSO M520. REVIEWED FOR CODE COMPLIANCE ADDDrlVEf DEC 15 2010 City of Tukwila BUILDIN( niviRinN SUBTITLE HVAC PLAN CURRENT REVISION 3032/57770703 SYMBOL B cAMw DEC Q 1 2010 PERMIT CENTER DATE 03/17/09 APPROVED BY DEPT. DATE ENGINEER PENROD CHECKED SQUIRES APPROVED CARRIGAN APPROVED TITLE MECHANICAL MASTER BUILDING 9 -099 COL E -G/1 -4 DEV. CENTER, WA SHEET 3M12 JOB NO. 57770701 COMP NO. DWG NO. 9- 099 -3M12 SQUIRESR: 09/10/10 09:5 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A REMOVE UH #5; REPLACE W/ AHRF2 B MOVE VALVES TO ENCL. ABOVE ROOF 3032/57770703 3032 HARR HARR RWS RWS 03/17/09 06/08/09 QL OE /NG° � B ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN HARR DATE 03/24/08 GE \ERAL \OTES REFERE\ �E 3RAWI \GS 109 - 099 - 4000 —M4 CO \STRUCTIO\ \CTES INSTALL NEW TRANE UNIT AHRF2 WITH TRANE — SUPPLIED CURB KIT. MODIFY ROOF AS REQUIRED. SEE DWG RFS12. ROUTE NEW STEAM AND CONDENSATE PIPES FROM EXISTING STEAM VALVE AND NEW CONDENSATE VALVE TO NEW AHRF2. W ROUTE STEAM AND CONDENSATE UP THROUGH ROOF TO VALVE & TRAPS INSIDE TRANE— FURNISHED VALVE ENCLOSURE (SAME AS OTHER ROOFTOP UNITS). REVIEWED FOR CODE COMPLIANCE 4 DDDAV 'p) DEC 15 ru ld City of Tukwila BUILDING' nn,I Inns HBM60 KEY PLAN SCALE: NONE artiVALA DEC Q 12010 PERMIT CENTER APPROVED BY DEPT. DATE CHECKED SUBTITLE HIGH BAY PARTIAL PLAN HVAC PIPING CURRENT REVISION 3032/57770703 SYMBOL B DATE 06/08/09 ENGINEER HARR 03/24/08 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 9 -99 COL. E —G/1 -4 DEV. CENTER, WA SHEET HBM62 JOB NO. 57770701 COMP NO. DWG NO. 9 -99 —HBM62 SQUIRESR: 09/10/10 09:54 I + I _ COND RET 2 1 2„ BOP EL 52' -6" i �6" -i MPS @ 60 PSI L' `- v) n 4"---t.4, / / x HJ H , r Y %+ / \ U v) CV ct CV 2 BLK STL SEE DWG 3v62 -1 /2" 0 o o 2 -1 /2" H z o z o m HBM62 S;,// M500 / 10' -0" _1 U © UP TO AHRF2 1 id) © - I— 1 B ;,I' — — I "CLWS i - - -- �, i 2 &R I GPM 35 G °� © I N7I Iv AHRF2 —�A A144"1 3"----44. E 1 © ct 7 14- -8 I.. L fr 1 -1 4 „ COND � J U . / 1 4" 1 1 /4" 10, - �" ) + — � / 4” CLWS &R DN ,I' H >> j} — -t— (10 ) „ 2 1/2" _J f - ,'� "' a J 51 'X51 " OPENING -EF -10 ON ROOF v) � J U N d v, H [H v7 - PIPE ANCHORS 7 1/2" / o Z O / 2"CONDENSATE 4" MEDIUM PRESSURE I// 1 3M62 RETURN ABOVE STEAM BELOW I M509 LI m.mmisrm,z n n n n I 1 1 /4„ U in---.-- 3 3 „ 2 A R 1 1/14' ---F —D i . i RET COND RET - --COND 2-2- ss ' i„ HPS 5 1—HPS - 6” 2 D +I I CLWS \._ / 1 6 "CLWS - ABANDONED SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A REMOVE UH #5; REPLACE W/ AHRF2 B MOVE VALVES TO ENCL. ABOVE ROOF 3032/57770703 3032 HARR HARR RWS RWS 03/17/09 06/08/09 QL OE /NG° � B ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN HARR DATE 03/24/08 GE \ERAL \OTES REFERE\ �E 3RAWI \GS 109 - 099 - 4000 —M4 CO \STRUCTIO\ \CTES INSTALL NEW TRANE UNIT AHRF2 WITH TRANE — SUPPLIED CURB KIT. MODIFY ROOF AS REQUIRED. SEE DWG RFS12. ROUTE NEW STEAM AND CONDENSATE PIPES FROM EXISTING STEAM VALVE AND NEW CONDENSATE VALVE TO NEW AHRF2. W ROUTE STEAM AND CONDENSATE UP THROUGH ROOF TO VALVE & TRAPS INSIDE TRANE— FURNISHED VALVE ENCLOSURE (SAME AS OTHER ROOFTOP UNITS). REVIEWED FOR CODE COMPLIANCE 4 DDDAV 'p) DEC 15 ru ld City of Tukwila BUILDING' nn,I Inns HBM60 KEY PLAN SCALE: NONE artiVALA DEC Q 12010 PERMIT CENTER APPROVED BY DEPT. DATE CHECKED SUBTITLE HIGH BAY PARTIAL PLAN HVAC PIPING CURRENT REVISION 3032/57770703 SYMBOL B DATE 06/08/09 ENGINEER HARR 03/24/08 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 9 -99 COL. E —G/1 -4 DEV. CENTER, WA SHEET HBM62 JOB NO. 57770701 COMP NO. DWG NO. 9 -99 —HBM62 SQUIRESR: 09/10/10 09:54 CURB FLASH & COUNTER FLASH AHU 31x31 SA DUCT 37x25 RA DUCT SEE STRUCTURAL FOR SUPPORT 24 "x60 "x 13' -0" PLENUM FIRE PIPE - REF 8" 48x18 SUPPLY DIFFUSER (TYP 5) TYPICAL AHU SECTION (TYP) (EXCEPT AHRB3) SCALE: NONE HBM 101 M500 HBM11 PERFORATED 16 GAUGE STEEL PLATE. 51% OPEN, STAGGERED 0.1875" DIAMETER HOLES 1 "x1 "x16 GA. ANGLE AROUND PLENUM AND ACROSS PLENUM 4' -0" O.C. SECURE TO PLENUM W /SHT MTL SCREW AH U CABINET ROOF SEE PARTIAL PLAN VIEW FOR EXISTING STEAM & CONDENSATE SIZES cY STEAM COIL STEAM COIL MPR (30) MPS (30) 2" T- X T- X ((SEE SCHEDULE FOR SIZE (TYP) 1/4" 1 -1/4" f 1 - Imo_ _ -j 2 -1/2" AHU STEA SCALE: NONE V L_ fVACUUM BREAKER 2" 2-1/2" 0 C CV- X T -X n C f ONIAHUENCLOSURE. ROOF PENETRATION (TYP) CG 1L PIPI\ /- 3/4" T -X III 3/4" G DETAIL (TYP) HBM60 M500 HBM61 3M62 7- 2 -1/2" 2-1/2" SYM A B C D F REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ISSSUE FOR PERMIT /BID ADD PERFORATED PLATE 534907 -03 COFFMAN 534907 -03 COFFMAN 01.12.05 05.19.05 INSTALL AHRB3 55776005 HARR RWS 09/20/06 INSTALL AHRB1 57770701 HARR 07/30/08 INSTALL AHRF2 3032/57770703 HARR 03/17/09 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN NFH DATE SUBTITLE 01.12.05 CHECKED ILI ENGINEER ILI 01.12.05 TITLE 01.12.05 CHECKED APPROVED APPROVED 141(0%•1 67 LEGE \J GE ERAL \RTES REFERE \CE 3RAWI\ GS CO \STRU CTIO\ \OTES INSTALL ALL NEW VALVES, TRAPS, AND FITTINGS TO CONNECT NEW AIR HANDLING UNIT AHRB1 TO EXISTING STEAM AND CONDENSATE SERVICES. REVIEWED FOR COMPLIANCE ADbDfl1 /En DEC 15 EUI;1 City of Tukwila BUILDINP nn►ISifN SECTIONS & DETAILS CURRENT REVISION SYMBOL 3032/57770703 cIrS$STAILA Utli 012010 PERMIT CENTER E DATE 03/17/09 BUILDING 9 -99 SHEET M500 JOB NO. 534907 -03 COMP NO. DEV. CENTER, WA DWG NO. 9- 99 -M500 C1891 A: 08/05/08 12:44 (L) CROSS BRACE CROSS BRACE ELECTRICAL BUS - REF i - --'-�— ' / i L /'l CROSS BRACE AHRB3 I W'r" Fl! 24" X 46" OVAL MANBARS M548 TURNING VANES - TYP SIGHT - BLOCKING INLET ELBOW 26" H X 68" W X 48" L J ELECTRICAL BUS - REF AH • B3 31" X 31" SUPPLY 25" X 68" RETURN mut TURNING VANES - TYP yam NENL? _ 40, 24" 0 TYP 24" DIA NECK TITUS 3 XC -310 DIFFUSER - TYP 46/24 OVAL ELEVATO\ LOO 1/2"0 STEEL CROSS BARS WELDED TO INTERIOR FRAME AND AT ALL INTERSECTIONS, 6 "OC FASTEN EXTERIOR FRAME ON SECURED SIDE TO WALL OPENING FRAMING. USE 1/4"0 MIN SHT METAL SCREWS OR WELD EXTERIOR FRAME TO STRUCTURE 2 PLACES MIN EACH SIDE v � v n ELEVATION LOO SCALE: 1/4' =1' -0" <I \G WEST r-G- HBM10 M548 RFM10 0 9 D D v <AG ORTH CROSS BRACES ROOF TRUSSES CRANE BRIDGE ENVELOPE J 0 (f) z NOM - RETURN V �H1 HBM10 M500 RFM10 EXTERIOR FRAME 1 1 /2"x1 1/2"x3/16" ANGLE (TO FIT AROUND OUTSIDE OF DUCT) INTERIOR FRAME 1 1/2 "x3/16" FLAT BAR (TO FIT SNUG INSIDE OF DUCT) 31" NOM - SUPPLY 25" NOM - RETURN A \BAR DETAIL SCALE: NTS REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INSTALL AHRB1 57770701 HARR 06/06/08 rd7. ziv ® ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN HARR APPROVED BY DEPT. DATE CHECKED RWS ENGINEER HARR RWS DATE 09/18/06 11/02/06 3/8" CARRIAGE BOLT 12" O.C. OR 2 PLACES MIN. EACH SIDE THRU INTERIOR FRAME, DUCT, AND EXTERIOR FRAME. INSTALL W/ BOLT HEAD ON INSIDE. DISTRESS THREADS AFTER ASSEMBLY. M548 HBM10 M548 HiOL7 LEE \D GENERAL \OTES REFERE \CE DRAW\ GS CO\ STRUCTIO\ OTES INSTALL MANBARS PER DETAIL - TYP 2 PENETRATIONS ON AHRB1. LOCATE AT THE ELEVATION OF THE ROOF PENETRATION, NOT IN DUCT ABOVE OR BELOW. 2 MAINTAIN CLEARANCE TO CRANE BRIDGE. REVIEWED FOR CODE COMPLIANCE A poonvEn DEC 15 21110 City of Tukwila BUILDINS nlvIci fM crrYISMn DEC Q 1 2010 PERMIT CENIER SUBTITLE SECTIONS & DETAILS CURRENT REVISION 57770701 SYMBOL DATE 06/06/08 CHECKED APPROVED 09/18/06 11/02/06 APPROVED TITLE BUILDING 9 -99 DEV. CENTER, W SHEET M548 JOB NO. 55776005 COMP NO. DWG NO. 9 -99 -M548