Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M10-181 - AMERICAN SPIRIT MOVING
AMERICEIN SPIRIT MOVING 955 INDUSTRY DR M10 -181 City A-Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 2523049034 Address: 955 INDUSTRY DR TUKW Project Name: AMERICAN SPIRIT MOVING Permit Number: M10 -181 Issue Date: 01/05/2011 Permit Expires On: 07/04/2011 Owner: Name: WALTON CWWA TUKWILA 1 LLC Address: C/O CTMT - WALTON RE TAX , 4678 WORLD PARKWAY CIR 63134 Contact Person: Name: JOFFRE SECHIER Address: 6802 S 220 ST , KENT WA 98032 Email: JOFFRE @COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA 98032 Contractor License No: COMFOMIO 1 5LA Phone: Phone: 425 - 251 -9840 Expiration Date: 06/01/2012 DESCRIPTION OF WORK: REPLACE (1) EXISTING 2 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH (1) NEW 2 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER AND CURB ADAPTER. Value of Mechanical: $5,500.00 Type of Fire Protection: UNKNOWN Permit Center Authorized Signature: Fees Collected: $257.06 International Mechanical Code Edition: 2009 ALA,A'JJA, I hereby certify that I have read and examined this pe and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether • - • ied herein or not. The granting of this permit does not presume to give : uthority to violate or cancel the provisions of any other state or local laws regulating construction or - performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this pe Date: Signature: Print Name: Date: 1—"Z."-'1 This perniit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4110 M10-181 Printed: 01 -05 -2011 • • PERMIT CONDITIONS Permit No. M10-181 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M10-181 Printed: 01 -05 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Mechanical Permit No. Project No. Ml0 -1 g( (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** :SITE LOCATION Site Address: 955 Industry Drive Tenant Name: American Spirit Moving WALTON CWWA Property Owners Name: Mailing Address: King Co Assessor's Tax No.: 2523049034 Suite Number: New Tenant: Floor: ❑ Yes ..No City State Zip [CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Joffre Sechier Mailing Address: 6802 S. 220th St. Day Telephone: (425) 251 -9840 Kent WA 98032 E-Mail Address: Joffre @comfortmech.com City State Fax Number: (425) 251 -9871 Zip [MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Mechanical Mailing Address: 6802 S. 220th St. WA 98032 Contact Person: Joffre Sechier E -Mail Address: joffre@comfortmech.com Contractor Registration Number: COMFOM1015LA City State Day Telephone: (425) 251 -9840 Fax Number: (425) 251 -9871 Expiration Date: 06/01/2012 Zip EARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: Fax Number: E; Mail Address: ENGINEER OF RECORD — All plans must be stamped by engineer of record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: Fax Number: E-Mail Address: H'\Applications\For ms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised 7 -2010 bh Page 1 of 2 • • Valuation of project (contractor's bid price): $ 5,500.00 Scope of work (please provide detailed information): Replace (1) existing 2 -ton rooftop gas packaged air conditioning unit with (1) new 2 -ton rooftop gas packaged air conditioning unit with economizer and curb adapter. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: 1 Indicate type of mechanical work being installed and the quanf ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp/1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment 1 air handling unit <10,000 cfm incinerator — comm/ind [PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEi' II AGENT: Signature: Date: Print Name: / 1' Joffre Sechier Day Telephone: (425) 251 -9840 Mailing Address: 6802 S. 220th St. Kent WA 98032 City State Zip Gate Application Accepted: ( Date Application Expires: I _ \Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 th Staff Initials: (4/ 1 Page 2 of 2 City of•Tukwila 1035501 -1 0004 12/21/2010 001 108 [ :CD Perri c Plus - General Fund AMERICAN SPIRIT MC 0 $257.06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site:' http: //www.ci.tukwila.wa.us Parcel No.: 2523049034 Address: 955 INDUSTRY DR TUKW Suite No: Applicant: AMERICAN SPIRIT MOVING RECEIPT Permit Number: M10 -181 Status: PENDING Applied Date: 12/21/2010 Issue Date: Receipt No.: R10 -02537 Initials: WER User ID: 1655 Payment Amount: $257.06 Payment Date: 12/21/2010 09:35 AM Balance: $0.00 Payee: JOFFRE SECHIER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. FINANCE ACCOUNT ITEM LIST: Description 257.06 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES City of Tdkwi la 6200 South enter Blvd, Tukwila, WA 1 Finance Department 1035501 -1 12/21/2010 BR1 T101 Tue Dec21,2010 09:39AM Trans #4 -4 4 $257.06 DCDGEN - DCD Permits Plus General Fund ID: AMERICAN SPIRIT MOVING Secondary ID: JOFFRE SECHIER 1 ITEM(S): TOTAL: $257.06 Visa PAID $257.06 www.ci.tukwila.wa.us 206 - 433 -1835 000.322.102.00.00 205.65 000.345.830 51.41 Total: $257.06 Printed: 12 -21 -2010 INSPECTION. RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION` 6300 Southcenter Blvd., #100, Tukwila. WA 98188' (206) 431 -3670 • Permit Inspection Request Line (206) 431 -2451 u�- Proje rRini,2f� ,9AJ SP/. 1 Inspection: Type of Iection: , oe A/ Z Address: l es , ( Date Called: Special Instructions: 0 2/66 6-0 / . Date Wanted: / ( _ , — / f 4 -. - / / a. Requester: Phone No: 0 ©e _ . . .1. 44 --4/ Approved per applicable codes. • El Corrections required prior to approval. COMMENTS: Pio epii; 4-0 1 le vAtio/ Date: -y El SPECTION FEE RE &UIRED. Prior dnext inspection. fee must be •aid at 6300 Southcenter Blvd:. Suite O. Call.to schedule reinspection. • PILE comer STRUCTURAL CALCULATIONS AND DETAILS FOR AMERICAN SPIRIT MOVING 955 INDUSTRY DRIVE TUKWILA, WASHINGTON PREPARED FOR: COMFORT MECHANICAL DECEMBER 17, 2010 CASCADE CREST CONSULTING ENGINEERS. INC. 21902 96TH AVENUE SE SNOHOMISH, WASHINGTON 98296 (206) 909 -7808 PREPARED BY: KEITH MOORE, S.E. REVIEWED FOR CODE COMPLIANCE APPPDVED JAN 04 nil City of Tukwila BUILDINS niuisinty RECEIVED DEC 212010 PERMIT CENTER J.33HS :TWOS o'J Li / :31va :a9N3 �V�t��'Ugjly� :i3Bro IcJ au lJNB 9/0XMsHOp Asam, Havas►a b» d"o 4r...5, 247 Uv vzro SZ Q e 4r) (') L, V — ' 1.91\01 fi Li-7 J1 d to 4.1 4 . 1dirtS 133HS 4 :31v3S 0//L�lZ! :31\fa t )71 / :21DN3 -'')7v ►t••°yNI in :L :i.o3road '314 marawnstazt otarmerara Alaimo sOYVIS►a 1' ►�- s o -T ="4 c% e- L Cry = Az. 09 L }'► = Y sv'ta TQS -d �rJGI \)-1.(s- )`e0`sal2,(4,,0) ")_,1.00.01 I-/\'71 � SZoo' o £ .1) J t'°,,,_ i v Q 4'71 151=A1 �- fia10 1 U^ /�. X11 P•o 019 etv (N/-z ) cirri d� sr Sfi eLc QQ • 7'O V °7 ---E, - - _zw "h t ' e- F«,rPR 1 LIT o sr-4i L., off, " PcCa 508470e-4-10S ) E)6 yK4 sot p 4-44 n @24)OL , Fw4s4114 G FL C*Scwoa CRUST CONSUL- MUG HIPAGINEERS. bac. PROJECT: u ENGR: K.\/ DATE: 12/ 1710 SCALE: SHEET GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS AND THE INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD MECHANICAL UNIT EARTHQUAKE WIND 25 PSF 529 POUNDS SDS = 0.891 SITE CLASS D TO E 85 MPH, EXPOSURE C 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE DRAWINGS, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER UTILIZED FOR SUPPORT OF THE MECHANICAL UNITS SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. MEMBERS SHALL BE HEM -FIR NO. 2 OR BETTER, MINIMUM BASIC DESIGN STRESS, Fb = 850 PSI, F„ = 150 PSI. 8. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C -2008. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. 017 9. "SISTER" NEW 2x4 TO EXISTING 2x4 WITH #10 x 3" 10d NAILS AT 8" ON- CENTER, STAGGERED WITH A LUS24 -2 HANGER AT EACH END. 10. CONNECT NEW UNIT TO CURB ADAPTER AND CURB ADAPTER TO EXISTING METAL CURB WITH MINIMUM #10 SHEET METAL SCREWS AT 18" ON- CENTER AROUND PERIMETER OF UNIT. IF DIFFERENT SCREW SIZE IS UTILIZED, VERIFY SPACING WITH STRUCTURAL ENGINEER 11. AT CONTRATOR'S DISCRETION, THE CONNECTION OF THE MECHANICAL UNIT TO THE CURB ADAPTER MAY BE PERFORMED UTILIZING (2) 18 GAGE x 1 -1/2" GALVANIZED METAL STRAPS PER SIDE WITH (2) #10 GALVANIZED SHEET METAL SCREWS INTO BOTH THE UNIT AND CURB ADAPTER AT EACH STRAP. 12. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 13. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGNH OF COLD - FORMED STEEL STRUCTURAL MEMBERS ". Project — UntiUedl Prepared By Unit Report For 2T GasEle 12/182010 03:44PM Unit Parameters Unit Model: 48ES-A240403 Unit Size: 24 (2 Tons) Volts- Phase - Hertz: 230 -140 Heating Type: Gas Duct Cfg: Vertical Supply / Vertical Return Healing Capacity: 40,000 Btuh. Dimensions (ft. In.) & Weight (Ib.) "' Unit Length: 4' 0.1875" Unit Width: 2' 8.625" Unit Height • 3' 4" Base Unit Weight 311 Ib Economizer Weight.. 65 Ib Adapter Curb Weight................ ....... 78 Ib "" Vests and Dimensions we apps e. Weigt4 does not Include roof curbs, unit packaging. field Metalled accessosfes orfactay installed options. Approximate dbnensione are provided prbnariy for shipping purposes. For exact dbnenstons and weights. refer to appropriate product data (Warranty Information 1 Year parts (std.) 10 Year parts on aluminum heat exchanger (std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 forexpianatlon of policies and ordering methods. Ordering Information Part Number Description Quantity, 48ESA240403 Rooftop Unit 1 Accessories CPCRIWTR008A00 240V Crankcase Heater 1 CPECOMZR007A00 CDI 3795 -4021 Economizer Adapter Curb 1 1 1,/ Packaged Rooftop Builder 1.27 Page 1 of 4 Certified Drawing for 2T GasEle Project -- UntIUed1 Prepared By: 12/16/2010 03:44PM !•114 0 1141!11 1242 41 404.11 (/Oi.41 OUTDOOR C011. LET SE VIEW (00.11 112.11 CONK 1413001 5011 TOP VEW lir 41 11103.0) Ap1T 3420 10 thll nmn Mit Italia! 3 n ialV " m,�� C Oat �1CTItt l CNAbtfERisTICt NJ 11. UNIT NE)ENT !41411 CEN3Ek Ol OIAYITUS INN I4 •A• E 1 2 46281.411151410404010I14 4 /e 00.0 �jNO 11.1 41.4 01. 40.3 4 1•t 401. 0) 13)0 !00423041.2 10.6416 21 00.0 10.18311 461.4 1.A0�0 N 1110 2084/304 -10 kt 140,0 0 )10 1010 ti• 4418 071.4 44.1411 100(0{.1' 310 {{Jl0111I04 106/230.1. 1 'O 41.0 26.1 44.144 164/16 311 11E114441416 040/010111 JJ8 140.1 {•114 1111 !t tilt/ 011.E it JAB./ 11.4 /1 112.3 111118 601.14431 4006(8 16 2 4 • • 4. 10201.141408t040 /040130 200/230 40.1 20.1 00.0 1.1 11.1 41.4 01. 40.3 4 1•t 401. 0) 13)0 !00423041.2 • QTLY 01201X0 21 00.0 4.24014 0044420100 . 12. ;.1 ,1 I0E4(•44IAN104//010111/316 2041230 41.0 21.1 41,0 26. 13.1 1.4111. 40.1 40214.40141 41610/411110 440 1.401.1 41.0 26.1 44.E 41.3111. 02.1 4.1/11 601.01 T- 0000 5010 4 113 1111.31 11TE: 60 14411.2 00074 EG004IIE101 Ail 1441011 IMAM mum 1132.10 46E281IPAANNEL 1.111' (21.1) 014. 8.0. Ptak 242110 710• 122.11 014. OOZE CCOT002 111 11 11.131)1 1506.41 10,110 1311.1110•),11 (254.41 1 -11/10 (46.01 0.1111 (32.41 4.1341{ 1122.21 .HOIIIIIIHII !II0110IIIIIhl 112' 111.134.4.1. 6.41 ENTRY 3114 14.01 RIGHT GE VN:W DRUM CU Mt110131 TO CCSHO1®A MAIL 100 OF 0NI�1 ... 1/ 333. ) 110 0ET OPPOSITE 0)6214 i! 0155 il. ROTTEN OF UNIT 0 10:01 Fl01 4Aa\ i/ (414.41 1�EC.112111® el0MA1La /44X45 704 20(2 40 00110 0010 04141 11 t. l! 101011 UNIT AND �UN(000N06E1p114�0/1121 a [0(0) lIOE 31 tt /11 000Bi0410400 EUIFK0011. t ENTRY RI005 AP OT1U 12 1100.01 REMO, *SIAM KO CE RAM A0• 1014045 (404 1011 ETU. C012 ACt(10 SIDE 1 1014.0) 401511 SDTNV {0055 45 1101{.60 121124/ FOp 411 *tbllti[Iil llt *l ' UNIT 10►. / 1011. 1 110E 0100L11� DD6TI /1 (411.0 0042 4022\ E 1! 11304.44551 80113X04 0131ANCEE :IT /NET i 411311NL4ENFODk0Nt1 Y)*102 4OWEd110E0, 01045)1 N 11'1 411621!!001 IN 11 ARE I3 )4 1 11111 (101) 13.1/1 (403,21 1.1414 (140.10 1 -7411 111.31 r • QTLY 01201X0 • 4.24014 0044420100 • 00 0 [ O0 tl 010 -�1 1 7/4 . 1 !30.61 (044.31 (205.11 REAR VIEW MR 1 07/24/09 I 111111114.1 - I SINGLE LONE ELECTRIC COOLING WITH GAS REHEAT (Sill I 48ESS00214 13. 0 Packaged Rooftop Builder 1.27 Page 2 of 4 QUOTE # 226355 • PLEASE CUT OPENINGS PER DIMENSIONS SHOWN BELOW k) $ t V E7 -% I S`t• 1 t4Cb- Wi $ 1 ADDED TO OLD CURB 0.6 2. MATERIAL: 18 ga. GALVANIZED STEEL 3. GASKET PROVIDED WITH CURB 4. INSULATION: 161112 LB De4SITY 881aMtr• 12TH' {� 1 ' 1 V4• 17 B •1_ aTt lntr i..—r Xa nir : a4ama NINVOMrocm►axmnwun Atbr Tag; { 1 tom". 12/8 UNLESS EXACT DIMENSIONS ARE PROVIDED TO CURB SHOWN I8 CDI STANDARD CONFIGURATION COI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BH NOTIFIED PRIOR TO PLACING AN ORDER. DATE oznvitasom nprno 00 0/V -"1 Saw ----� wmwowrami ~au • D �. (b.:4E '" ' mpeofted 1.3785.4021 V""U+e\"1723 ev 3Ff8III— QUOTE # �,...�I =AM .fi954021 . Ida MO t a Project: - Untitledl Prepared By: Unit Report For 2T GasEle 010 03:44PM Unit Parameters Unit Model: 48ES- A240403 Unit Size: 24 (2 Tons) Volts- Phase - Hertz: 230 -1 -60 Heating Type: Gas Duct Cfg: Vertical Supply / Vertical Return Heating Capacity: 40,000 Btuh Warranty Information 1 Year parts (std.) 10 Year parts on aluminum heat exchanger (std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (1b.)*** Unit Length: 4' 0.1875" Unit Width: 2' 8.625" Unit Height. 3' 4" Base Unit Weight: 311 Ib Economizer Weight ....... .............................65 Ib Adapter Curb Weight...... ...... ......................78 Ib Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Ordering Information CODE REVIEWED FOR-- onnveD JAN 04 'ail of�Y Tukwila DIVI inns Part Number Description —"'lip 48ES- A240403 Rooftop Unit 1 Accessories CPCRKHTR008A00 240V Crankcase Heater 1 CPECOMZR007A00 CDI 3795 -4021 Economizer Adapter Curb 1 1 MEW DEC 21 2010 PE - ' IT CENTER Packaged Rooftop Builder 1.27 Page 1 of 4 Certified Drawing for 2T GasEle Project: -Untitled/ Prepared By: 12/16/2010 03:44PM 31 7/16 1798.51 2 -3/4 169.91 21 9/16 9-15/16 1541.11 1252.41 11 15-15/16 1404.81 OUTDOOR COIL DRAIN OUTLET 3/4' 19.01 N.P.T. 12-13/16 % 3/8 122.0] DEEP 1325.41 32 5/8 1828.11 LEFT SIDE VIEW UNIT 0 P.D. POI 1115 TECHNOLOGIES SYRACUSE, 1Y CARRIER 19(01 1HIi DOCUI(NI IS THE PROPERTY 05 CARRIER CORPORATION AND I5 DELIVERED UPON 1330 EXPRESS 001/11101 1HA1 1140 CONTENTS WILL Dl DI DISCLOSED 01 USED 911HOUT CARRIER 0011gA110I'S WRITTEN CONSENT, SUBMISSION Of 1101E DRAWINGS M /00156111 DOES NO7 CONSTITUTE PA T PERFOR A10E DR ACCEPTANCE Cf CONIgACT, UNIT ELECTRICAL CHARACTF AI ST ICS 0411 WT. UNIT HEIGHT [N /MN CENTER OF GRAVITY IN /MM LB KG 'A' X Y 2 48061. 1414241040 /060130 208/230 -1 -60 304 137.6 40 -1/8 1019 22-13/16 519.4 15 -5/16 388.9 15-11/16 398.5 48661-/N14301040/0601131510 208/230-1, 208/2303.60 309 140,0 42-1/8 1010 22-13/16 519.4 15 -5116 388.9 15-13/16 401.6 48101 - /414361060/090113 /510 208/230-1, 208/230 -3 -60 319 144.6 46 -1/8 1112 22 -13/16 579.4 15-5/16 388.9 16-5/8 422.3 48601- /N14361060/290/60 460-3-60 333 150.9 46-1/8 1112 22-13/16 579.4 15 -5/16 388.9 16 -5/8 422.3 UNITS VOLTAGE CORNEA WEIGHT L8 /N6 48E01- /4/4241240 /060130 208/230 45.6 20,7 60.8 27.6 91.1 41.4 106.3 48,3 48E5(- /41430/043 /060113/510 208/230 46.3 21.0 61.8 28.0 92.6 42.1 108.1 49.1 48(31-/414361060/090/13/510 208/230 41.8 21.7 63.8 28.9 95.6 43.4 111.6 50.6 48051- /X14361060 /090160 460 47.8 21,3 63.8 28.9104.647.5 116.6 52.9 33/16 181.01 125.41 3 -5/8 192.11 TOP VIEW . MOOR COIL 41 (1193.81 Imlfflm'I'ffl nannnemn. 4 1/2 1114.31 r 4.7/8 1 1123.81 1 14 -5/16 [J61. 51 MEM EJ 0 COMPRE550. PANEL 19 3/16 11224 01 LOWER PANEL FRONT VIEW LECTRICAI ACCESS PANEL NOTE: ALL TABLE DATA RELEVANT FOR ALL FACTORY INSTALLED OPTIONS EXCEPT ECONOMIZER 1 -1 /8' 128.61 DIA. N.O. POWER ENTRY 118' [22,21 DIA. HOLE CONTROL ENTRY 19-15/16 150 .41 15 -5/8 1396,9110.3/16 1258,81 1-13/16 146.01 21/16 152-41 4-13/16 1122.21 I!IHIIIIIIIIII !I (/2' [ /6Y . Y(4.P,1. 645 ENTR 3/16 14.81 RIGHT SIDE VIEW RECURED CLEMAMS TO (7WP35T1aE WIL INCHES (NMI TOP OF UNIT 14 1355.61 DUCT SIDE DF UNIT .. .......2 150 8) SIDE OPPOSITE DUCTS 14 1355.61 60TT04 OF UNIT 0 [0.01 FLUE PANEL 36 [914.41 P@ REOItRED CLEARANCES. BETWEEN UNITS, POWER ENTRY SIDE UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE... RECURRED CLEARANCE FOR OPERATION AND SERV= INCHES (MM) ....42 (1066.81 ..36 1914 01 ..42 11066.81 INCHES /441 EVAP COIL ACCESS SIDE .........36 1914.01 POWER ENTRY SIDE „ ,,....42 11066.81 (EXCEPT FOR NEC REQUIREMENTS) UNIT TOP .. ,.,...48 11219.21 SIDE OPPOSITE DUCTS .. .,,. ..36 [914.01 DUCT PANEL .,.. ... ..12 (304.01. •MINIMUM DISTANCES:IF UNIT IS PLACED LESS THAN 12 [304.81 FROM WALL SYSTEM,THEN SYSTEM PERFORMANCE MAY80 COMPROMISED. !10 0 .01 6 -9/16 1166.11 3 -7/16 187.31 DIMENSIONS IN 11 ARE IN MM 9 -1/8 1250.8] 21 5/8 9 1/8 (549.31 (250.81 REAR VIEW 9010 01/24/09 512(10EDES SINGLE TONE ELECTRIC COOLING WITH GAS REHEAT (SRI 48ES500214 REV 3.0 Packaged Rooftop Builder 1.27 Page 2 of 4 SUP LY DUC OPENING RETURN DUCT OPENING 00 00 I I 1 9 -1/8 1250.8] 21 5/8 9 1/8 (549.31 (250.81 REAR VIEW 9010 01/24/09 512(10EDES SINGLE TONE ELECTRIC COOLING WITH GAS REHEAT (SRI 48ES500214 REV 3.0 Packaged Rooftop Builder 1.27 Page 2 of 4 Project: — Untitledl Prepared By: Performance Summary For 2T GasEle 12/16/2010 03:44PM Part Number:48ES- A240403 ARI SEER. 13.20 Base Unit Weight. 311 lb Base Unit Dimensions Unit Length: 48.2 in Unit Width. 32.6 in Unit Height. 40.0 in Unit Voltage- Phase - Hertz. 230 -1 -60 Air Discharge. Vertical Fan Drive Type. Direct Actual Airflow. 858 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy 31.44 BTU /Ib Evaporator Leaving Air DB. 61.2 F Evaporator Leaving Air WB: 58.6 F Evaporator Leaving Air Enthalpy: 25.42 BTU /Ib Net Cooling Capacity. 23.23 MBH Net Sensible Capacity: 17.38 MBH Total Unit Power Input: 2.10 kW Coil Bypass Factor: 0.096 Heating Performance Heating Airflow: 858 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 104.6 F Gas Input Capacity: 40.0 MBH Gas Heating Capacity. 32.00 MBH Temperature Rise. 34.6 F Supply Fan External Static Pressure: 0.35 in wg Options / Accessories Static Pressure Economiser: 0.09 in wg Wet Coil: 0.04 in wg Total External Static: 0.48 in wg Fan RPM: 1050 Fan Motor Size, hp: 1/2 NOTE: High Motor Speed, Vert Electrical Data Minimum Voltage* 187 Maximum Voltage. 253 Compressor RLA: 12.8 Compressor LRA: 58.3 Outdoor Fan FLA (ea): 1.2 Indoor Fan Motor FLA: 4.1 Power Supply MCA: 21.3 Power Supply MOCP (Fuse or HACR): 30 Acoustics Sound Rating. 76.0 db Packaged Rooftop Builder 1.27 Page 3 of 4 Performance Summary For 2T GasEle Project: - Untitledl Prepared By: 12/16/2010 03:44PM Sound Power Levels, db re 10E -12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 66.0 250 Hz NA NA 66.0 500 Hz NA NA 70.5 1000 Hz NA NA 71.5 2000 Hz NA NA 67.5 4000 Hz NA NA 62.5 8000 Hz NA NA 58.5 Packaged Rooftop Builder 1.27 Page 4 of 4 FORM NO. 7859-1P DATE: 6/09 SUBMITTED TO COMPANY - DRAWN BY: T, HUBBARD JOB NAME: EQUIPMENT: NOTES: Down Discharge Economizer with Filter Rack for Carrier 48 /50ES,EZ,VL 024- 036,A24 -A36; 48/50VT 024- 030,A24 -A30; 50GL,JZ 024- 036,A24 -A36 Units Part Number: ECD -SDSML ** Econo: -Part ECD - SDSML- ADB -CD ECD -SDSML - ENT -CD ECD - SDSML -NC -CD Controls Dry Bulb Enthalpy No Controls Supply air cover panel. Shipped on HVAC unit. Features: • Economizer for down application only. • Fully assembled, easy to install. • 2" Filter rack and 1" TAW filters provided. • Rainhood ships assembled, includes a water entrainment filter and is constructed of prepaint steel. • Low leak outside air damper. E —• Barometric relief damper. Carrier Equivalent: CPECOMZR007A00 FILTER RACK SIZE 1" Filters 2" Filters (2) 12" x 20" x 1" (1)10 "x20 "x 2" (1)12 "x20 "x 2" NOTES: 1. Relays required for heat pump units can be field supplied or order Carrier Kit CPRLYKIT001A00. 2. Economizer should not be used on XL,XT INFINITY units. 3. Economizer includes harness extensional for older units with no economizer harness factory installed. 4. The "NC" economizer models do not include actuator, controller, sensors, or wiring harness. Coil 0 00 Replacement panel shipped with economizer (some newer units will include this panel) Panel for filter and controls access Economizer outside air damper Economizer's barometric relief damper 00 00 00 00 00 00 00 00 00 00 00 00 Filters provided Rainhood with water entrainment filter SIDE VIEW Down Discharge Aluminum water entrainment filter THIS DOCUMENT 15 THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT MICROMETL CORP. - 3035 NORTH SHADELAND AVENUE, SUITE 300 - INDIANAPOLIS, IN 46226 - 1- 800-662 -4822 - MICROMETL SPARKS - 905 SOUTHERN WAY - SPARKS, NV 89431 - 1- 800 -684 -4662 Q IIOTE # 226355 PLEASE CUT OPENINGS PER DIMENSIONS SHOWN BELOW •\ 3: \J E —'9 c S Iac- c Notes: 1.1.5° ADDED TO OLD CURB O.D 2. MATERIAL: 18 ga. GALVANIZED STEEL 3. GASKET PROVIDED WITH CURS 4. INSULATION: 1" 1 1/2 LB DENSITY „L L 3313/16" 12114' ` 4' —.1 I+— 1 11 Attn: 'M 11 Tag: 1t• L. Approval :, 43 7116" EXISTING CURB LAYOUT Q)k Vr 41 15118" 23112' 22112" RETURN SUPPLY 49 114' R/S WILL BE COVER WITH 24GA MATERIAL UNLESS EXACT DIMENSIONS ARE PROVIDED TO CPI. CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. DESCRP1ON DATE APPROVED WINE DESIGN 11/21/10 MWG 1 -- 30 5113" --1 50 3/4" CUM. MOKNf .054 APPRO8313 0011 VERIFY SUPPLYAND RETURN OPENINGS 801E ANY CHANGES 'CALL WM4ANY ourenot 9 •84118431313 DR41883 (5 01(3313 78.30 Od :SS wz- 10..wmI. MDn6Oy. November 72.2010 2S13i PM 1T680 TYLER 8T NW CDI "U(R ER. 86030 1- 37954021 QUOTE #: lawn. 13795.4021 .coo 1:18 { "..s OP 2006 Washington State Nonresidential Energy Code Compliance Form :.006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address AMERICAN SPIRIT MOVING Date 12/17/2010 955 INDUSTRY DR For Building Department Use TUKWILA, WA 98188 Applicant Name: JOFFRE SECHIER Applicant Address: 6802 S. 220TH ST, KENT, WA 98032 Applicant Phone: 425 -251 -9840 w Project Description Briefly describe mechanical system type and features. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2C06 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address AMERICAN SPIRIT MOVING aj %SModel No.1 Date 12/17/2010 Total CFM 955 INDUSTRY DR SEER or EER For Building Dept. Use Location TUKWILA, WA 98188 CARRIER Applicant Name: JOFFRE SECHIER 800 Applicant Address: 6802 S. 220TH ST, KENT, WA 98032 Applicant Phone: 425 -251 -9840 [] Includes Plans Compliance Option Equipment Schedules REPLACE (1) EXISTING 2 -TON GAS PACKAGED ROOFTOP UNIT WITH NEW 2 -TON ROOFTOP GAS PACKAGED WITH ECONOMIZER AND CURB ADAPTER. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Q Simple System 0 Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' aj %SModel No.1 Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location HP -1 CARRIER . d -A24 23800 800 ECONO 13.50 32000.00 ROOF Heating Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 RTU -1 CARRIER 48ES -A24 23230 800 ECONO 40000.00 32000.00 ROOF Fan Equipment Schedule Equip. ID Brand Name Model No.1 CFM Sp1 HP /BHP Flow Controls Location of Service 1If available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: 4 Constant vol? Split system? 4 Air cooled? ✓ Packaged sys? <20,000 Btuh? Economizer included? II 4 If Heating Only: <5000 cfm? <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating /Cooling or Cooling Only Air Cooled, Constant Vol? Heating Only Refer Section 1421 <70% OSA Yes plit Syste <= 84,000 Btuh? Yesj. •ol Ca. <20,000 Btuh? Outd or Adjacent to utdoor of Ca <54,000 Btuh? otal Ca . wo economize <240,000 Btuh or 10 %? Simple System Allowed (section 1420) E:ompiex Systems • Use Complex Systems (section 1430) Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist ; MECH -CHK 008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address AMERICAN SPIRIT MOVING Date 12/17/2010 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule Ml yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M1 n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls n.a. 1412.1 Temperature zones Indicate locations on plans n.a. 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control n.a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule Ml 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M1 n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate cig load & water econoe &cig tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling Ml n.a. 1413.4 Humidification Indicate direct evap or fog atomization w /air economizer 1414 Ducting systems n.a. 1414.1 Duct sealing Indicate sealing necessary n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Comp etion ' equtrements n.a . 1416.2.1 Commissioning Provide commissioning plan n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing &functional testing n.a. 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training n. a. 1416.2.5 Comm. Report Indicate requirements for prelim. &final commissioning report n.a. 1434 Separate air sys. Indicate separate systems on plans yos Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer "SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover "no" is circled for any question, provide explanation: • • PENNI PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M10 -181 DATE: 12 -21 -10 PROJECT NAME: AMERICAN SPIRIT MOVING SITE ADDRESS: 955 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: d2'• ildng Dlvision MN Public Works 4re Prevention fit 1—t° Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-23-10 Complete Incomplete n Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 01-20-11 Approved Approved with Conditions 't Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL INC UBI No. 601954041 Phone 4252519840 Status Active Address 6802 So. 220Th Street License No. COMFOMI015LA Suite /Apt. License Type Construction Contractor City Kent Effective Date 6/1/1999 State WA Expiration 6/1/2012 Date Zip 98032 Suspend Date County King Specialty 1 Heating /Vent /Air - Conditioning And Refrig (Hvac /R) Business Type Corporation Specialty 2 Unused Parent Company icenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM'01OJT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/19994/30/2012 Active COMFOP'064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 06/01/2005 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Amount JACKSON, HERB J Vice President 01/01/1980 9849307 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS & SURETY OF MD LPM4041162 06/01/2002 Until Cancelled $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 FEDERATED MUTUAL INS CO 9849307 06/01/2010 06/01/2011 $1,000,000.00 05/03/2010 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.00 05/01/2009 6 FEDERATED SERV /MUT INS CO 9849306 06/01/2005 06/01/2006 $1,000,000.0004 /25/2005 5 FEDERATED MUTUAL INS CO 9849306 06/01/2004 06/01/2005 $1,000,000.0004 /30/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01 /05/2011 PARCEL DATA Parcel 1252304 -9034 r Jurisdiction TUKWILA Name 1WALTON CWWA TUKWILA 1 LLC Site Address . 825 INDUSTRY DR 98188 Geo Area 70 -50 Levy Code ;2340 } Propert Type ; C Plat Block / Building Number Spec Area 520 -30 Plat Lot / Unit Number Quarter-Section-Township-Range SW -25 -23-4 Legal Description BEG AT E 1/4 COR OF SEC 26 -23 -4 TH N 88 -06 -42 W 105.84 FT TH S 01 -47 -28 W 90.66 FT TO TPOB TH FR TPOB S 88 -12 -32 E 233 FT TAP ON C/L OF A PRIVATE DRIVE TH ALG SD C/L S 01 -47 -28 W 577.17 FT TAP OF CURVE TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT 77.78 FT RAD 250 FT & C/A 17 -49 -33 TAP OF REV CURVE TH FR A TANGENT WH BEARS. S 16 -02 -05 E ALG ARC OF CURVE TO RGT 77.78 FT RAD 250 FT & C/A 17-49-33 TAP OF TANGENCY TH TANGENT TO PRECEDING CURVE S 01- 47-28 W 430 FT TAP ON NLY MGN OF MINKLER BLVD TH LEAVING SD C/L ALG SD MGN N 88 -12 -32 W 257 FT TH LEAVING SD MGN N 01 -47 -28 E 1160.23 FT TO TPOB LESS UP RR OPER R/W ASSESSOR DATA River. 11 AREA OF WORK REVISIONS No changes shail be cnadQ to the Pcc;,pa of work without prior approve! of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees: {Ct 201e ging County r ..Rnalkitt tw C , th e: m s rihf O goo 6001 a cp ati Ottegoi SITE PLAN t Map of: 955 Industry Dr Tukwila, WA 98188 -3413 Ion i251tt M:inkler Blvdi. VICINITY MAP t PROJECT DESCRIPTION: 1 REPLACE (1) EXISTING 2 -TON ROOFTOP GAS PACKAGED UNIT WITH (1) NEW 2 TON ROOFTOP HEAT PUMP UNIT WITH ECONOMIZER AND ADAPTER CURB. 2 REUSE EXISTING AIR DISTRIBUTION "NO WORK ". 3. USE EXISTING PROGRAMMABLE THERMOSTAT. GENERAL NOTES:. 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 4. INSTALL RETURN AIR DUCT SMOKE DETECTOR FOR UNITS WITH GREATER THAN 2,000 CFM 5. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF. 6. PROVIDE AIR BALANCE AND COMMISIONING REPORT. 7. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 8. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. 9. INSULATE ALL DUCT PER WSEC TABLE 5 -11. 10. SEAL ALL DUCT PER WSEC. HVAC Equipment Schedule # Brand Model Ton CFM OSA CFM Econo. SP Cap. Cool SEER Btuh -In Btuh -Out ,AFUE ,. Weight RTU -1 CARRIER 48ES -A24 2 800 80 0- 100% 0`.5 23,230 13.2 40,000.1' 32,000 80% 530 OFFICE SPACE "NO WORK" RTU -1 SEPARATE PERMIT REQUIRED FOR: ,IAechanical ra Electrical bg Plumbing 11 Gas Piping City of Tukwila BUILDING DIVISION WAREHOUSE "NO WORK" PARTIAL ROOF PLAN t REVIEWED FOR CODECOMPLIANCE APPROVED JAN 0 4 2U11 City off BUILDING ISlon, FILE COPY Permit Plan win, approval Oat to errors and dons. Approval of construction documents does not authorize . the violation of any adopted code or ordinance. Recept of approved • • • # y and condkions is ar owledged: ► r to ILDING DIVISION M[bH8I RECEIVED DEC 212010 PERMIT CENTER REVISIONS MECHANICA COMFORT F. 425.251.9871 Z 0 — co moo a. 0, ( Q Z I— Q 0 J Z 2 W —� DATE: SCALE:. DRAWN: CHECKED: 12 -21 -10 NONE JTS 1 00 -000