HomeMy WebLinkAboutPermit 2541 - Chow Yin Enterprises - Warehouse / OfficeCN- 8�3 -147 .i• 4 • BUILDING PERMIT CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 PERMIT NUMBER a�� DATE OF ISSUANCE June 10, 1983 EXPIRES December 10, 1983 JOB ADDRESS 1114 Andover Park West, Tukwila, WA 98188 LEGAL DESCR. LOT NO. BLOCK TRACT El SEE ATTACHED SHEET OWNER Chow Yin Enterprises LTD PHONE ADDRESS 227 East Georia Street, Vancouver RC ZIP V6A116 1, 1. CONTRA TOR Self (Tenant) PHONE f ADDRESS 1114 Andover Park West, Tukwila, WA ZIP 98188 LICENSE NO. N/A SST NO. N/A BUILDING USE Warehouse /Office (CSM Distributing Inc.) CLASS OF WORK NEW ❑ADDITION UCLA EMODEL ❑REPAIR ❑OTHER (Specify) BLDG. AREA 1st FL. 2nd FL. BASEMENT GARAGE DECK MEZZANINE # OF STORES TOTAL S.F. VALUATION X 639 9,000 I CERTIFY THAT THE ABOVE INFORMATION IS TRUE AND CORRECT, THAT THE APP ABLE CITY OF TUK A REQUIREMENTS WILL BE MET, AND T �,� AM AN THORI D AGENT FOR THE PROJECT. OWNE ENT SIGNA URE FEE DISTRIB: BUILDING 75.00 PLAN RVW. 49.00 DEMOLITION BOND OTHER TOTAL 124.00 COMMENTS: TYPE CONST, OCC. GROUP OCC. LOAD FIRE ZONE USE ZONE AUTO SPRINKLERS REQ. 5N B2 6 -° C -M EYES 0 N THESE INSPECTIONS ARE REQUIRED BY LAW 1. Driveway 2. OK to 3. Roof 4. OK to 5. Wall- 6. Structure approach and pour footing sheathing enclose board complete and/ slope and /or and nailing framing nailing or OK to foundation OK OK occupy FOR IN 'E TIIOJV CALL 433 -1849 BUILDING FFICI , CITY OF TUKWILA THIS PERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING BUILDING PERMIT • CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 PERMIT NUMBER f-,(7)(-1/ DATE OF ISSUANCE .7utle° 10, 1983 EXPIRES December. 10, 4983 JOB ADDRESS 111.4 Andover Park West, Tukwila, WA 98188 LEGAL DESCR. ',LOT NO. N BLOCK TRACT 4 SEE ATTACHED SHEET OWNER Chow Yin Enterprises 'LTD PHONE ADDRESS 227 East Georia Street, Vancouver BC ZIP V6A116 CONTRACTOR Self (Tenant) PHONE ADDRESS 1114 L;.ttclo,,rbr.• Park West, Tukwila, WA ZIP 981813 • LICENSE NO. /A. SST NO. N/A 'Warehouse/Office (CSM Distributing Inc.) . CLASS OF WORK ❑NEW., • ❑ADDITION ❑.REMODEL ❑REPAIR ❑OTHER (Specify) BLDG. AREA 1st FL. 2nd FL. BASEMENT GARAGE DECK MEZZANINE # OF STORES TOTAL S.F. VALUATION X 639 9,000 I CERTIFY THAT THE ABOVE INFORMATION IS TRUE AND CORRECT, THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE MET, AND THAI' I' AM AN AUTHORIZED AGENT FOR THE PROJECT. / OWNER. /'AGENT SIGNATURE FEE DISTRIB. BUILDING 717, no PLAN RVW. n fin DEMOLITION BOND OTHER TOTAL 1.24.1)0 COMMENTS: TYPE CONST. ' OCC. GROUP OCC. LOAD FIRE ZONE USE ZONE AUTO SPRINKLERS REQ. 5N B2 6 -- C —M Ll YES ❑ NO THESE INSPECTIONS ARE REQUIRED BY LAW Driveway 2, OK to 3. Roof 4. OK to 5. Wall- 6. Structure � I1. �'� approach and pour footing sheathing enclose board complete and .. slope and /or and nailing framing nailing or OK to i foundation OK OK occupy 4`. FOR INSPE/ TION CALL 433 -1849 BUILDING!OFFICIAV, CITY OF TUKWILA THIS PERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING CITY OFTUKWILA Central Permit System 7 t:ontrol No. -- Permit No. - 4f FINAL APPROVAL FORM TO: ❑ Building ❑ Planning ❑ Public Works • p(Fire Dept. ❑ Police ❑ Parks/ Recreation Project Name (Y2 Address ! f Type of Permit(s) !7�)(1,,4 This project is nearing completion. Please investigate your area of responsibility and indicate below either your final approval or necessary corrections. If no response is received within one week, it will be assumed that the project is of no concern to your department and a certificate of occupancy may be issued. This project N ,T approved by this de artment, the f Vowing corrections are necessary: _ -2-'155:44P . G r k',i -e r. v`? 4</ > J ~ r i' -e-74d ,/ 401 - ()�. ,C",ePI ear✓ 1... ,C' /re -/ J` IMIL•' / �i'. Authorized ignature - Date This project is pproved b h partment:' Authorized Signature' III Date w CPS Form 3 CITY OF TUKWILA,. PERMIT NUMBER CONTROL NUMBER F3-1---17 CENTRAL PERMIT SYSTEM - PLAN CHECK ROUTING FORM TO: [_ BLDG. C PLNG, III P.W. FIRE I I POLICE L__1 P.& R. PROJECT sS f'Y\ � ��� b b4 +y a "% ADDRESS i J 4 (1-vvi o v,,v- P/C Gv s`7 DATE TRANSMITTED `� 3 RESPONSE REQUESTED BY C,P,S, STAFF COORDINATOR RESPONSE RECEIVED. PLEASE REVIEW THE ATTACHED PROJECT PLANS AND RESPOND WITH APPROPRIATE COMMENTS IN THE SPACE BELOW, INDICATE CRUCIAL CONCERNS BY CHECKING THE BOX NEXT TO THE LINE(S) ON WHICH THAT CONCERN IS NOTED: tc7tie 4 / ; $- 9/1R�'f °y ).-43 CO4,,,7 S�,, /7 /.. -1)1) /1 4, bdi).t) I v; %1h, /n Con (//. NO 19e'),1Q- CO / 9// ,ed. El 2) 11601617 EXIT /LI Exit ooh- ❑ Y e 3- 1' C (t'Pc c y v; r s -e-i 7'S ) Cf� // -rp '-' h mss •2 p O PS/ cs n 5"--1/ • 1-- S 01; i O • ❑ 8) 9) 10) 11) 12) ❑ 13) ❑ 14) ❑ 15) D, R, C, REVIEW REQUESTED ❑ PLAN CHECK DATE PLAN RESUBMITTAL REQUESTED El COMMENTS PREPARED BY, PLAN APPROVED 11,0 C, P, S, FORM 2 ■ U U CALL TOLL ,1E p ?E (WITHIN WASHINGTON.. 1.800.862.635 CALL TOLL F') JE (OUTSIDE WASHINGTON 1.800420.4776) 1114 ANDOVER. PARK WEST • P.O, BOX SSOS4 • TUKWILA, WA 90100 • : PHONE (200) 070.4007 rep c)3 T. /Sc.)/ ,ome r oc.pr O tc- Aiv�doi JUN 91983 83- 740 -KW (**THIS QUOTE. NOT VALID AFs ,'�t 30 DAYS * ** �`:` PROPOSAL y WASHINGTON STATE SALES TAX NOT INCLUDED To: C.S.M. DISTRIBUTORS 1114 Andover Park West Seattle, WA 98 ATTN: Stan Morheim PROJECT: ARCHITECT: BID DATE: DATE BARCLAY DEAN, INC. 1917 120th N E. Bellevue, Washington 98005 BUS. BA- RC- LI -347KT 206/451 -0053 5/25/83 xxzxxxacxadnoxalxafcxdcxxxxxxxxxxxxtkxx We are pleased-to quote as follows: DEMOUNTABLE PARTITION SYSTEM, as manufactured by Domtar KW 700 Actionwall, with Pebble Beach "Champagne" color in stock vinyl with bronze trim: Approximately 105 LF of partitioning, 9' high WITH: (5) doors, frames, & passage sets (4 - Hollow Core) (1 - Solid Core) Rubber Base (brown) cut in 2' lengths 600 sq. ft. of insulation MATERIAL ONLY, FOB Jobsite $3,142.00 CEILING SYSTEM 2 x 4 LAY -IN GRID PANELS, as . manufactured by U.S. Gypsum, dropped below ceiling approximately 8 ": Approximately 504sq. ft. of ceiling - MATERIAL ONLY, FOB Jobsite $ 650.00 ADD for Journeyman Working Supervision•'... $ 300.00 per day Delivery: Terms: Net, 30 clays. R CEjlr'?') CV'FY Car " - ,n=rtt A JUN 91983 BUIL[t:t ii i L):.r t .' .CONDITIONS . 1. The above proposal is subject to withdrawal or ,ensrun ,t not accepted within 30 days .Quotations are subject to stenographic errors. 2. When required, shop drawings will be furnished and, when approved try the purchaser or architect, they shall be deemed to be the correct inter• • pretation and design and dimensions ' 3, The customer agrees to provide adequate storage facrinres 4ir the Materials delivered to the job and to furnish necsesary light and power. and elevator service, if available, when contract calls ton installation: 4. No back charges will be accepted by us unless sPecrtrcalry agreed upon in writing. 5, We will not be responsible for loss or damage arising 1(on) .delays caused by lack of correct or complete data; by changes or ravisiona; by late approval of drawings; by dire, floods. siris es, lock.i,its nu is, by ,1:r utehts in plants of those furnishing us with materials; by Inability to obtain material or skilled labor; by delays of transportation careers or by any other causes beyond our Control. 6, Should the purchaser tender his own purchase order or contract, all terms and conditions of the proposal shall by this reference, be in* corporeted therein. 7: Interest at tell riill. of 1 . °u pi r month will L,' • r.n, pat'„" .0 . , . ' ti.i.,it , .... per ii ii i fi.,;. Accepted • BARCLAY DEAN, INC, By ' Date By l/Y 4 4t . san R. Gerth al. BARCLAY DEAN, iNC. PELLA PRODUCTS COMPANY BetImo, WA 98005, 1917 120th Are. NE • 2061151.0053 Anchorage, AK 99503, Arctic Business Park 600 W 41st • 9011276.1828 l ' • w r,••••-.-, {;'26 1- \�Lfi i—t; - LR,W !ALL Dcn- AR. >;>IMOUtJrA LE =ma 5 ill tGT ��1'L M��N (s) (,1 R12 L - ,.)Ll. && a1� U (�i �77ti17 Yr Z JUN : 91988 NNW } 1• 3,4,E 4,,10.1 ALL FARTmc ► 9' 1.4461-f -TWAVM F-x1� ALL tAJAU, f t't --0 6100( GYPSUM GR+WALL 3 0 am • • — CITY OF TUKWILA APPROVED JUN 10 1983 AS NOTED& f_RUILDING DEPT. Domtar Gypsum America Inc. DOMTAR 10.1/Do '7%./ED 01111..,A JUN 9 1903 •1 .!3" to CC Cit INDEX CEILING TRACK FLOOR TRACK PANEL PREPARATION PANEL APPLICATION BASE TRIM INSULATION. PANEL TERMINAL CORNER CHALKBOARD PANELS DOOR FRAME GLAZING. 'PAGE 3 6 -7 12 -21 NEXT TO DOOR - CEILING HEIGHT 12 NEXT TO PANELS - CEILING HEIGHT 13 -14 OVER PANELS 15 -16 NEXT TO DOOR - OVER PANELS 17 "H" MEMBER 18 -20: MULLION ATTACHMENTS 21 GLASS INSTALLATION PANEL REMOVAL FIRE RATED 22 22 23' ACTIONWALL is a registered trademark of Domtar Gypsum America Inc. „ CEILING TRACK 12" TYPE S -12 PAN HEAD SORE WS 60" O.C.. \�+►® CEILING TRACK CEILING TRACK PERPENDICULAR TO GRID • CEILING TRACK 1 60" /2" O TYPE S -12 PAN HEAD SCREWS .C. CEILING TRACK PARALLEL TO GRID 13/16" SPLICE CLIP CORNER. CLIP; :. 13/16" . Attach track to ceiling with suitable fasteners. Space fasteners 60" o.c. for the nonrated partitions and 48" o.c. for 1 -hour partitions. . Where shelving is applied to the partition or seismic design requires additional bracing, fastener spac- ing must be reduced. With conventional ceiling•grid, 1/2" Type S -12 pan head screws may be used. When required, apply two rows of . 1/4" and 3/8" foam tape behind track. Splice clips 764A can be used to provide alignment of long runs of ceiling track. They should be staked to each side of one end of each piece . prior to installation. Since the clips are smaller than the slot, stake with the clip next to the top retainer. Corner clips 763A are used similarly with mitered corners of the ceiling track. FOAM TAPE FLOOR TRACK . Secure floor track to hard surfaces with suitable nails, screws, or pins spaced a maximum of 48" o.c. Apply two rows of 1/4" x 3/8" foam tape underneath track. When shelving is applied to the partition or seismic design requires additional bracing, fastener spacing must be reduced. For non -rated partitions installed over loop pile nylon carpeting, the track may be applied with 6" length of 2 "• wide RCU -84 Velcro tape spaced 24 o.c. FLOOR TRACK FLOOR .TRACK ON ^CARPET POSITION OF. CLIPS TOP OF PANEL BACK OF PANEL EDGE CLIP PANEL • Cut panel height 1" shorter than distance between floor and ceiling. Be sure to cut..' through vinyl surface before breaking boards. Cut stud 1/2" shorter than panel height and place on panel 1/2" from top to use for clip . alignment. • Install five C -2 edge clips every 18" along edge of panels. Four clips may be used if panel is screwed at bottom. EDGE `CLIP Position by eye at center of slot. Tap clips fully to seat them. Insert C -3 spring steel clips into each edge clip. The holes in the C -2 clip are the normal center position of the C -3 clip. Some mechanics find it easier to first fit the C -3 clip under the C -2 clip before driving the C -2 clip into the panel.: CEILING TRACK` tiz_ T c PANEL APPLICATION PANEL/ FLOOR TRACK 700 STEEL STUD 1. insert two flange spacers in the 700 steel studs, one at about 3' from the floor and the other 18" above the first. (Optional) 2. To install panel, push top of panel between stud and ceiling track (see sketch A). Then push in bottom of panel while resting on floor and pul- ling out on middle of panel (B). Push panel against stud to engage clips (C). 3. Npte that the C -3 clip may be moved 1/4" in or out from the normal center position (holes in C -2 clip) if required to fit studs already installed. Or, studs already installed on one side may be moved 1/4" also. 4. A 700 steel stud can be used where wall begins with uncut panel edge. Stud is attached to other wall with track screws or other fasteners 24" o.c. Panels snap onto stud without additional trim parts. 5. Cut Ending Intersection can be used to start or end any panel. Steel stud is attached to other wall with track screws or other fasteners 24" o.c. Panels are screwed to stud with panel screws 24" o.c. and are placed within 1/2" of corner to be concealed by trim. 6. An alternate to steel stud uses 504A PANEL AND STUD APPLICATION aluminumor 550P plastic intersection and attached to other wall with screws or other fasteners spread 24" o.c. Panels are inserted without fastening. 7. A 700 steel stud is cut 1 -1/2" short of ceiling height. Place stud into position in floor track and press against panel so clips snap onto stud. Then install panel on other side. Adjust first pair of panels to be plumb and square. Continue to erect panels in same sequence. If floor is not level, occasional shimming of panels at floor may be necessary to maintain plumb and square panel installation. 8. An intermediate 2 -1/2" DWS steel stud is required for 48" panels. Cut to length and insert similar to 700 steel stud. Apply spots of panel adhesive on stud 18" o.c. before installing panel. 9. When ending a run of wall, measure the total opening before the last full panel is placed. Cut and install -MO last panel before installing the last full panel. ADHESIVE 50 STEEL STUD ALTERNATE STARTING DETAILS 04A w 550P SECTION END 250 S EEL STUD STAGGERED, JOINTS • WIDTH VARIATION ADJUSTMENTS. • Because of normal manufacturing tolerances of wallboard plus using plain, vinyl, or vinyl tackboard finishes, the finished panel width can vary 1/16" and, in some cases, up to 1/8 ". Adjustments can be made as follows: 1 2. Check widths Make a habit of checking widths especially when different colors and patterns are used on opposite sides of the wall. Different production runs and even those of one color can have variations. When walls are longer than 14 feet, this can be important. Start in center of run - On larger walls, start installing panels at the center of the run and go both ways. If one side is completed, start the other side at the center to reduce variation to one -half at each end. The C -3 clips can move 1/2" in the C -2 clips and the steel stud can flex 1/8" so that a 5/8" variation can be taken up at the end of a run. • Use double -700 steel studs - By installing steel studs back to back with panels offset 1" as shown a 1" adjustment can be obtained. • Adjustment at full height door frames - On long corridors with cross walls running off other side and where full height,. doorframes are used, width adjustments are made at each along the corridor • Cut panels at intersections - Long corridor or other walls can be adjusted on the intersecting wall side. Behind the intersection, the panels can be cut and spreod open to adjust for gain or cut out to adjust for loss. • Make special panel widths - Over mitered door frames and when other solutions do not work, the only solution is to cut a panel narrower and wrap the vinyl around the back. To do this, make a very straight deep cut from the back side of the panel. Break the board and peel vinyl back. Clean the raw gypsum edge, sand if necessary to make a straight edge. Use Elmer's glue or equivalent, wrap . :. vinyl around edge and back, and staple to back of panel. 546P BASE TRIM EASE TRIM BASE TRIM FIELD NOTCH BACK OF BASE TRIM AT OUTSIDE CORNER BASE TRIM AT CORNER ACOUSTICAL INSULATION SPOT STAPLE INSULATION TO BACK OF PANEL 1. Attach base trim clips 18" O.C. with 9/16" staples per clip. 2. Press base trim over clips at normal room temperatures to avoid thermal expansion. 3. Place an additonal clip at end of each piece of base trim. 4. At outside corners cut back of base trim as shown and bend 900. White fracture line which occurs on outside of bend can be removed by warming gently with a lighted match. -8- 1. If insulation is required, a glass fiber insulation bate is spot stapled at top of panel on one side during panel erection. 750A T 250 STUD _L 14A OR 48P BLK. 250 STUD %" PANEL TERMINAL CORNER . Normal terminal installation requires panels to be screwed to steel stud with face of stud at desired opening. Terminal part is cut to length and pressed over panels. ." Complete one wall with a steel stud terminating "plumb and even with the floor track of the other wall. Fasten panels with panel screws 24" o.c. Attach outside panel of adjoining wall with panel screws 24" o.c. s� 3. Place steel stud in corner and attach to other steel stud with —�- panel screws 24" o.c. Place. remaining panel and screw to 13A OR steel stud with panel screws 49P BLK. 24" o.c. 4. Cut corner trims to fit between base and ceiling tracks. • Place bead of adhesive on each leg of corner trims and press trims on. corners. Use Fuller's Adhesive SC -1189 or Goodrich PI. 200 for the aluminum trim and Fuller's Adhesive SC -1141 or SC -1.189 for plastic trim. 5�e' CHALKBOARD PANELS 4.I.JI G /AhAAMRD PAHLIS 1.. 'Chalkboard panels are installed. 5451" some as other panels except • CHALKBOARD " Chalkboard Edge is placed in PARTITION ✓OINT3 vertical joint between chalkboard 3 panel and other panel. Chalk - Ye-j AWL, 1 WAWL, D , board panels require extra care WE� in. handling. CHALK MIL . : Attach chalkrail at vertical joints into studs with two 1 -1/2" Type .S sheet metal screws. CEILING TRACK DOOR FRAME BEND WEB OF STEEL STUD TO MAKE TAB FOR ATTACHMENT 1/2" TYPE S -12 PAN HEAD SCREWS 250 STEEL STUD DOOR STUD AT CEILING TRACK CEILING HEIGHT DOOR 250 STEEL. TRACK 0 -&---sSTEEL 25STUD 1/2" TYPE S -12 PAN HEAD SCREWS DOOR STUD AT FLOOR TRACK CEILING TRACK 1. Door frames are supported at each side with steel studs. Clear opening between studs is door width plus 3/4 ". Locate stud on hinge side and plumb; then screw to floor track and top of ceiling track. Install second stud. 2. Place face panels 1/4" short of face of door stud. • . 3. Cut door jamb on hinge side to he&ght (cutting from bottom) and press over panels. Adjust jamb to be plumb, and attach 1- 1/2;'. self - drilling door frame screws thru door jamb, panel, and steel stud on each side of jamb at locating groove. 4. Mace other door jamb over panels. Snap door head into ceiling track. Push jamb tight against head, and position bottom of jamb for correct door opening. Install screws. 5. Cut battens to length and snap onto door jambs. SNAP -IN DOOR STOP 4 -0OOR FRAME DOOR HEAD AT CORNER -10- CEILING TRACK BEND WEB OF STEEL STUD TO MAKE TAB FOR ATTACHMENT 250 STEEL STUD BEND WEB OF STEEL STUD / TO MAKE TAB FOR ATTACHMENT DOOR HEIGHT PLUS 3/8" ABOVE FLOOR 1/2" TYPE S -12 PAN HEAD SCREWS DOOR STUD AT CEILING TRACK LESS THAN CEILING HEIGHT DOOR 1/2" TYPE S -12 PAN HEAD SCREWS CORNER BRACE DOOR FRAME HEAD Door frames are supported at each side with steel studs. Clear opening between studs is door width plus 3/4" (or 36 -3/4" for 3' door). Locate stud on hinge side and plumb; then screw to floor track and ceiling track. Install second stud. 2. Cut and prepare a section of steel stud for supporting header to fit between vertical studs and install with track screws 3/8" above door frame opening. 3. Install all panels around door with edge of panel 1/4" short of face of studs. If panel joint occurs in area above door, cut section of aluminum stud short of. clear opening above door, and fasten panel edges with clips. If panel joint occurs at door jamb, place adhesive spots on vertical stud above door. Screw panels to studs around door frame with panel screws 30" o.c. to be concealed by door frame. 4. Place hinge jamb over panels, make plumb, and attach 1 -1/2" self - drilling door frame screws thru door jamb, panel, and steel stud on each side of jamb at locating groove. 5. Place head and strike jamb so mitered comers fit properly. Attach corner clips with 1/2" pan head screws provided with door frame. Locate bottom of jamb for opening width, and attach jamb and head with door frame screws. Snap battens onto door frame. DOOR FRAME JAMB DOOR FRAME - MITERED CORNER BRACING -11- • GLAZING NEXT TO DOOR - CEILING HEIGHT DOOR FRAME 250 STEEL STUD NOTCH SILL 765A GLAZING SILL DOOR FRAME SCREWS GLAZING SILL NEXT TO DOOR • DOOR FRAME 250 STEEL STUD 756A '..-GLAZING MULLION 765A. GLAZING SILL DOOR FRAME SCREWS GLAZING SILL AND MULLION NEXT TO DOOR -12- 1. Use steel stud in place of floor track. 2. Install vertical steel stud door fram- ing and door Frame and fasten. 3. Notch glazing sill and place over steel stud floor track into door frame. Glazing sill is cut to necessary lengths from 48" or 60" units. Fasten door frame to sill with door frame screws. 4. Cut snap -in reglet same length as glazing sill and snap into ceiling track. • •Cut glazing mullion to length and insert into door frame. Fasten door frame to mullion with door frame screws. As an alternate, a 2 -1/8" 18 ga. steel stud with 1" flanges is used for framing in lieu of the DWS -250 steel stud. Use snap -in reglet (754A) in lieu of the glazing mullion. GLAZING NEXT TO PANELS - CEILING HEIGHT 700 STEEL ;STUD. 250 STEEL STUD 250 STEEL TRACK NOTCH TO RECEIVE GLAZING MULLION PREPARATION FOR GLAZING MULLION NEXT TO PANELS . Use steel stud in place of floor track. 2. The 700 steel studs are used for all glazing units. Complete a panel next to glazing unit. 3. Cut glazing mullion to length measuring from floor to 1/2" above bottom of ceiling track . Notch flanges of steel stud used as floor track in order to clear glazing mullion. Push glazing mullion into ceiling track and over 700 steel stud. Drill 9 /64" hole through center groove in iamb at midheight, and place 2 -1/2" self - drilling screw through Iamb and Into stud. 763A CLIP 250 STEEL TRACK PREPARATION FOR GLAZING SILL NEXT TO PANELS 1/2" TYPE S -12 PAN HEAD SCREWS 765A GLAZING SILL GLAZING SILL AND MULLION NEXT TO PANELS Place glazing sill over steel stud floor track. Glazing sill is factory cut to necessary length for 48" and 60" units, and these lengths con be field cut to achieve narrower units if desired. . Cut snap- in .reglet same length as, glazing base and snap into ceiling'. track. ... .� +.. .... ..... a•..• .t.o. .i.. <. .•.. •.... ., .,.. . t.ti SG'Nx ..� ,.R ,n 5... i. -•H.. .. •.. uw• .... ...,. ....r.. GLAZING POSITION OF GLAZING SILL t, 1" TYPE S SCREW ,r STEEL STUD PREPARATION OF GLAZING SILL AT CORNER NOTCH TO FIT AROUND STUD \.. . ... .752 A GLAZING.SILL END OF. GLAZING SILL -15- 1. The 700 steel studs are used for all glazing units. Complete a panel next to glazing unit. 2. Cut gypsum panels to height, and snap to 700 steel studs. 3. Cut and install horizontally 1/4" below level of panels a piece of steel stud and attach to face panels. This is done to prevent sill From rocking. It may be necessary to use extra shims. . For 48" units, snap 48" panel on one side of wall, and install next 700 steel stud. Cut piece of steel stud measuring from bottom of horizontal stud to floor; apply adhesive spots and install in center of panel. Place panel on opposite side. 756A • GLAZING MULLION TYPES SCREW 752A GLAZING SILL . . Trim length of glazing sill as necessary to fit actual panel width below; notch to fit around 700 steel stud, place over panels, and screw to horizontal steel stud. 6. Cut glazing mullion measuring from top of glazing sill to 1/2" above bottom of ceiling track. Push glazing mullion into ceiling track and snap into glazing stud. • STEEL STUD S 754A NA `__, 756A REGLET GLAZING MULLION. STEEL STUD. GLAZING HEAD AT CORNER DOOR FRAME 250 STEEL STUD 752 APE GLAZING SILL TRIM SIDES TO BUTT AGAINST DOOR JAMB PREPARATION FOR GLAZING SILL AT CORNER NEXT TO DOOR .DOORFRAME SCREWS \. DOOR FRAME 250 STEEL STUD..• 756A f---= GLAZING MULLION r--- 752 APE GLAZING SILL mss/ 250 STEEL STUD GLAZING SILL NEXT TO DOOR -17 If unit is next to ceiling height . door, install steel stud and door frame first. Notch glazing sill to fit inside door frame as shown, and attach glazing sill at other and only. Push glazing mullion firm against sill at door and place inside door frame so that face of glazing mullion is 3/8" from door frame. Place door frame screws through door frame, glazing mullion, and steel stud. • Cut snap -in reglet some length as clear opening at glazing sill, and snap into ceiling track. NOTCH TO RECEIVE GLAZING MULLION GLAZING "H" MEMBER 11•116111 250 STEEL STUD 250 STEEL TRACK PREPARATION FOR GLAZING SILL NEXT TO. PANELS •760A "H" MEMBER 250 STEEL STUD 250 STEEL TRACK 1/2" TYPE S -12 PAN HEAD SCREWS "H" MEMBER NEXT TO PANELS 250 . _ STEEL STUD �760A "H" MEMBER 765A GLAZING SILL. GLAZING . SILL AND "H" MEMBER NEXT TO PANELS -18- 1. Use steel stud as vertical stud attached to top and bottom track. Screw attach face panels to stud. 2. Notch track to receive full length "H" member. Attach "H" member to stud with 1/2" screws spaced 24" o.c. 3. Place glazing sill over steel track and insert into "H" member. 4 754A SNAP -IN REGLET 250 STEEL STUD 760A "H" MEMBER GLAZING HEAD AT CORNER 760k "H",MEMBER GLAZING SILL 754A SNAP -IN REGLET GLAZING REGLET AND SILL NEXT: TO PANEL$ . -'9- . Cut snap -in reglet some length as glazing sill and snap into ceiling track. Cut snap -in reglet to fit between top track and glazing sill and snap into "H" member. CEILING TRACK 1/2" TYPE S -12 PAN HEAD SCREWS. FABRICATE SPECIAL CLIP • Where glazing is to be on both sides of "H" member, attach "H" member to bottom and top track with clips . and screws. . ii UITABLE FASTENER BEE 763A CLP H MEMBER 1 /2" TYPES 12 PAN HEAD SREWS NOTCH TRACK TO250 RECEIVE "H" MEMBSTEEL TRACK • • 1" TRIM HEAD SCREW \■ 766A GLAZING SILL 754A SNAP -IN REGLET VA" TYPE S -12 SCREWS 774A CONNECTION CLIP 766A GLAZING SILL GLAZING MULLION ATTACHMENT TO SILL 760A "H" MEMBER 754A SNAP -IN REGLET 1%" TYPE S -12 SCREWS 774A CONNECTION CLIP With glazing sill in place, cut glazing mullion or "H" member to length. Position on sill at correct location and install connection clip. Attach connec- tion clip to sill with two 1 -5/8" Type S -12 screws. Note connec- tion clip is reversed with mullion and "H" member. 2. Attach mullion or "H" member to connection clip with a 1" trim head screw. 766A GLAZING SILL "H" MEMBER ATTACHMENT TO SILL 754A SNAP -IN REGLET 3/4" TYPE S -12 PAN HEAD SCREWS 774A CONNECTION CLIP 146" TYPE S -12 SCREWS IL GLAZING SILL ATTACHMENT TO "H" MEMBER 3: With full height "H" member in place, cut glazing sill to length and place over panels. Use two connection clips attached to sill with two 1 -5/8" Type S screws and "H" member with one 3/8" Type S -12 pan -head screw. GLASS INSTALLATION 757P GLAZING BEAD MITERED CORNER ON GLAZING BEAD 1/16" GLAZING BLOCK 2 CORNERS BOTTOM CORNER OF GLAZING AREA 1. Glass size is clear opening Tess 1/8 ". Glass may be 3/16" or 1/4" thick. 2. Press glazing bead into groove on one side using glazing lubricant. Cut glazing bead on 45° miter at comers. Place glass on 1/16" glazing blocks and place glazing bead in remaining groove. Make sure to use lubricant on both sides of glass around perimeter in addition to use on the glazing bead. PANEL REMOVAL TOOL MAY BE MADE FROM SCRAP MATERIALS • IN FIELD PANEL REMOVAL TOOL TOOL BEING INSERTED. PANEL REMOVAL ROTATE TOOL DOWN AND PULL OUT Panels are removed for installation of utilities, change of panel color, or complete relocation of wall. Place tool (see sketch) under bottom of panel center, then rotate tool down so edge goes behind panel. Pull bottom of panel out about 2" and remove tool. 3. Grasp panel near bottom and pull out. Panels on other side may be pushed out at bottom from behind. After first panel has been removed, remaining panels are removed on one edge first without using tool. System is installed similar to nonrated wail with these exceptions: 1. A piece of 3" thick glass fiber insu- lation is wedged into the ceiling track. 2. Wall panels are 5/8" thick Type X gypsum board panels. Stud length is same as panel (1" shorter . than floor to ceiling height) so that it is inside top track when resting on floor. 4. If stud length is 1 -1/2" shorter than floor to ceiling height (same as used in nonrated system), the stud must be raised by use of steel shim after panels are in place. 5. Clips are aligned similar to nonrated system except they must be positioned to match bottom narrower portion of slots. • rao S?EL 8/110 PARTITION JOINTS. .98•awvELs. . • In, the cavity, insert 5/8" Type X gypsum board panels. They' are 24" wide for the 24" and 48" face panel systems, • and 30" wide for the 30 "'system. As an alternate for the 30" cavity panel, two pieces of '16" boards, overlapped, may be used. Fasten bottom edge of panels on both sides to bottom track with '1- 1/4 "•.: Type S • screws spaced •12" o.. c. and to bottom of_each stud. C. BARCLAY DEAN, INC. PELLA PRODUCTS COMPANY tlellovw. WA 90005, 1817 120th Are. NE • 2061451.0053 Anchorage, Al'. 99503, Arctic Business Park 600W 41St • 9071275.1828 I to Vti it I r ri K16.1 Cys• Pe. • DRWJALL R r) o 6112.1.1C-14 MAIN mrloo 1-41*117 I46001 Dri4F-4; , _ (ity WA Per jvc.4,, ‘17/eda ..... • • 0 C44 4. ALLFARrtricOKNG at&ti itW PqrzizJeg Ot.4)L ALL- 6-1706(.. BARCLAY DEAN, INC. PELLA PRODUCTS COMPANY ittilevuti, WA HOW 1017 120th Ay*. NE • 20111451•000 Anchorago, Al 90503. Atetlt Busin0si Palk 600W 41t1 9071276.1828 1 It , Et, 17R. 1--)2.1-iouturASCrl. S'11211C1 tv1Aie.4 immaL4 '22.1 P gal.fr ')I.A.(561 L4 1,1-1-171.41 0 E2e-C7g1c4h__ ; • -0 * 41 . . : ct Foc1,4 1,01224401416. plec L. YfAta 2 71.1.SULATM ALLFARTrios.-UN6 9, ott.-irt PqrA213RuJAta, et.u-y AJ-i vvAti. tANri.-0 6-ro&K._ -. . _. %,, . ,..EP V SLPPARD Complete Electrical 22659 Pac. Hwy. MIDWAY, Phone 11 It ill liat & NELSON ELECTRIC i & Sound Service So. P. 0. Box 3366 WASH. 98031 TR 8-7333 PROPOSAL SUBMITTED TO CMS Distributing PHONE 575 -4567 DATE I 5 -19 -83 STREET 1114 Andover Park West JOB NAME Gffice wiring CITY, STATE AND ZIP CODE Tukwila, Washington 98188 JOB LOCATION Same ARCHITECT DATE OF PLANS JOB PHONE We hereby submit specifications and estimat,ps for: Labor and materials for the following electrical work in conjunction with office additions: A. Furnish and install 13, 2, X 41 florescent T-Bar fixtures with lamps. B. Furnish and install one 2000 watt and one 1500 watt baseboard heaters. C. Furnish and install approximately 45, of wiremold with receptacles • on 12" centers. D. Install a separate heating circuit in each small office for. , a portable plug in heater. E. Install five light switches and 10 wall receptacles as per ri CL owner instructidan. F. Furnish and install all circuit breakers, conduit, boxes, .,- and___.._.._ and wire to complete job as per sketch provided. ___________ Proposal $1,638.00 Tax 124.48 _ -_... _..__.__- _._.. Permit 41.00 Total $1,803,48 The Frame hereby to furnish material and labor — complete in accordance with above specifications, for the sum of: One thousand eight hundred and three and 48/100 dollars($1,803.48 ) Payment to be made as follows: Net 20 days All material is guaranteed to be as specified. All work to be completed in a workmanlike / r / mariner according to standard practices. Any alteration or deviation front above specifica• Authorized Signature -0 • 4 ■ - • ..-e . I I I ' • tions Involving extra costs will be executed only upon written orders, and will become an . extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays beyond our control. Owner to carry tire, lmnedu and olher mg essnny ikon,,,,, n Nolo I his propolu l may he Our workers are fully covered by Workmen's Compensation Insurance withdrawn by us II 1101 accepted within �� days n ? rtE41tat re of f rA}U1SMl —The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Date of Acceptance: Signature Signature TORY l la T COPYRIGHT 1040 •-• NEW ENGLAND BUSINESS SERVICE. INC.. TOWNSEND. MAUL vt t141YiLet SC PPARD & NELSON ELECT:: Complete Electrical & Sound Service 22659 Pac. Hwy. So. P. 0. Box 3366 MIDWAY, WASH. 98031 Phone TR 8 -7333 IOPOSAL SUBMITTED TO CMS Distributing PHONE 575 -4567 GATE 5 -19 -83 mEET 1114 Andover Park West JOB NAME Office wiring TY, STATE AND ZIP CODE Tukwila, Washington 98188 JOB LOCATION Same RCHITECT DATE OF PLANS JOB PHONE We hereby submit specifications and estimates for: Labor and materials for the following electrical work in conjunction with office additions: A. Furnish and install 13, 20 X 40 florescent T -Bar fixtures with lamps. B. Furnish and install one 2000 watt and one 1500 watt baseboard heaters. C. Furnish and install approximately 450 of wiremold' with receptacles on 12" centers. D. Install a separate heating circuit in each small office for a portable plug in heater. E. Install five light switches and 10 wall receptacles as per owner instruction. F. Furnish and install all circuit breakers, conduit, boxes, and_... and wire to complete job as per sketch provided. Proposal $1,638.00 Tax 124.48 Permit 41.00 ToLa 1 $1,803.48 We frame hereby to furnish material and labor — complete in accordance with above specifications, for the sum of: One thousand eight hundred and three and 48/100 doilars($l,803.48 Payment to be made as follows: Net 20 days All material is guaranteed to be as specified. All work to be completed in a wurkmanllke manner according to standard practices. Any alteration or deviation from above speclbca lions Involving extra costs will be executed only upon written orders, and will become an extra charge ova and above the estimate. All akreenlents cuntnlyrnl upon ,,tn■rs, Al r uni■► or delays beyond our control. Owner to carry lire, turnadu chit Ulbrl Ile, wo.Aey IIIVIIuNI e Our workers are fully covered by Workmen's ConNtrensaain bnuraNle Authorized Signature Nuln I Ins pieluwnl nary bra withdrawn by us if not accepted within -SU days. Arrt 1tUtuE of Ifroposal —The above prices, specifications and conditions are satisfactory and are hereby accepted. You ate authorized to do the work as specified. Payment will be made as outlined above. Date of Acceptance: Signal ore Signature /OHM Ile 11 COPTNIGHI 1900 . NSW (NGLAND OONINF%$ aUNVICL INC, TOWN {CND. MASS. Control Number S BUILDING DEPARTMENT CITY of TUKWI LA 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 433 -1849 APPLICATION FOR PERMIT RECEIVED CITY OF TUtwVI(...4 JUN 91988 BUILDING DEPP. DATE C/7/63 . PERMIT NO. WHEN VALIDATED EXPIRES JOB ADDRESS /l/ V Avectic.A. IAQK wE — LEGAL DESCR. LOT NO. BLOCK TRACT SEE ATTACHED SHEET / OWNER ` C/y«� //y rn�T-eZ 6-ES /70 `�4 I PHONE ADDRESS �• 1/41 CeJe • �G 22 7 - E;1ST 67,17,q_ J / Y ZIP �/ n 711/ C� i7 �C� CONTRACTOR �-2 ' l — .-,e 1 I-- eo- e.rrt-ca H SYS4--ei4Ls- PHONE 5--75-_ 45-67 ADDRESS )ZIP LICENSE NO S ST NO. BUILDING USE Lat enb.,/se- /©/c'��F TENANT CS'/I-f 4/5 2Nc /5 TR /dc, zi.� CLASS OF WORK ❑ NEW 'ADDITION REMODEL ❑ REPAIR ❑ OTHER (Specify) BLDG. AREA 1st FL. 2nd FL. BASEMENT GARAGE DECK MEZZANINE # OF STORES TOTAL S.F. /� VALUATION �{ PLANNING/ SEPA BOND 6,370 �`6� c2, . 0 O NAME OF APPLICANT (PLEASE PRINT) c S nr5 ?. /e/ T /y� 16'c �'' , ADDRESS / / /tl/ /�i%,CC) /44)/4 63.7' PHONE 5-- 7S --''/$ 7 I CERTIFY THAT THE INFORMATION FURNISHED BY ME IS TRUE • ND CORRECT AND THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE MET. // , / , SI "rT RE OF APP • • NT DO NOT WRITE BELOW THIS LINE TYPE CON T. OCC. GROUP OCC. LOAD • FIRE ZONE USE ZONE AUTO SPRINKLERS REQ. DETECTOR • • S 3 -. /-SENT �/ . — L ES ❑ NO J YES D NO RVW ' PLANS: RETURNED APPRO ED FEE DISTRIB. BUILDING 7‘,0Z) FIRE DEPT. q 2 S �� JrBJ fj�I "( ���?�� PLAN RVW. 4, " /' j 9 P 1 DEMOLITION PLANNING/ SEPA BOND OTHER PUBLIC WKS. TOTAL 11-4,,,: RECEIPT NO. 6102 COMMENTS: APPROVED FOR ISSUANCE: BY The tax as, ssment area shall not extrnd beyond the . ( following describecl'real property: 1110 ! IN That portion of Government Lot 1 of Section 35 (v� �'U$ - and the Southeast 1/4 of the Southeast 1/4 of ! i Section 26, Township 23 North, Mingo 4 East, 111011[12-.1 W.1•i. , in the City of Tukwila, King County, WI-I 0 ,e[ Washington, described as follows: ( e,t; Beginning at the Northeast corner of said Govern- `�""" ment Lot 1 of Section 35; thence North 87 °44'08 West along the North line of said Government. Lot 1, a distance of 949.49 feet to the True Point of Beginning; thence South 01 °51'39" West a distance of 107.44 feet; thence North 88 °08'21" West a distance of 333.00 feet to the West margin of Andover Park West; thence North 01 °51'39" East along said West margin of Andover Park West a distance of 109.79 feet; thence North 01 °47'29" East along said West margin of Andover Park West a distance of 634.01 feet to the North line of Southcenter Industrial Park; thence South SS °12'31 East along said North line of Southconter Industrial Park a distance of 346.50 feet; thence Southwesterly along a curve to the left, the center of which bears South 70°57'17" East, having a radius of 300.00 feet, an arch distance of 90.34 feet; through a central angle of 17°15'14"; thence South 01 °47'29" West a distance of 547.77 feet to the True Point of Beginning; Situate in the City of Tukwila, County of King,. State. of Washington. . LICH BIT "