Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit MI02-027 - GULL INDUSTRIES - RESIDENCE DEMOLITION
GULL INDUSTRIES INC M102027 City ofTukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0005800011 Address: Suite No: MISCELLANEOUS PERMIT 15616 WEST VALLEY HY TUKW Permit Number: Issue Gate: Permit Expires On: M102 -027 03/22/2002 09/18/2002 Tenant: Name: GULL INDUSTRIES, INC Address: 15616 WEST VALLEY HY, TUKWILA, WA Owner: Name: SCHACHT VERNON Address: PO BOX 567, TAHUYA WA Contact Person: Name: DICK POTTER Address: 3404 4 AV S, SEATTLE, WA Contractor: Name: GULL OiL COMPANY Address: P.O. BOX 24687, 3404 FOURTH AVENUE SOUTH Contractor License No: GULLOC *165BS Phone: Phone: 206 624 -5900 Phone: 206 624-5900 Expiration Date: 12/13/2003 DESCRIPTION OF WORK: DEMOLISHED 1,323 SQ FT SINGLE FAMILY RESIDENCE. PUBLIC WORKS ACTIVITIES INCLUDE LAND ALTERING, HAULING, STREET USE, CAPPING OF WATER AND SEWER SERVICE. Value of Construction: Type of Fire Protection: Type of Construction: $7,000.00 Fees Collected: Uniform Building Code Edition: Occupancy per UBC: $2,231.00 1997 0007 Public Works Activities: Curb Cut/Access/Sldewalk/CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: Land Altering; Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: Y Sewer Main Extension: N Storm Drainage: N Street Use: Y Water Main Extension: N Water Meter: Channelization / Striping: Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 294 c.y. Start Time: End Time: Private: Public: Private: Public: * * Continued Next Page ** doc: Miscperm MI02•027 Printed: 03.22 -2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: �, (ttl Date: 5-) I hereby certify that t have read and examined this permit and know the same to be true and correct, All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per ;i•• oe �»' presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru;Ili' e1,�: formance of work. I am authorized to sign and obtain this mechanical permit. Signature: .,. ,i Date: 3 it+. to °L. Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of Issuance, or If the work is suspended or abandoned for a period of 180 days from the last Inspection, doe: Miacperm M102-027 Printed: 03.22.2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0005800011 Address: 15616 WEST VALLEY HY TUKW Suite No: Tenant: GULL INDUSTRIES, INC PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M102 -027 ISSUED 03/04/2002 03/22/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division, 3: All permits, inspection records, and approved plans shall be available at the Job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The Issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the Jurisdiction, No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: ** *PUBLIC WORKS DEPARTMENT *" 7: The applicant must notify the City Utility inspector at (206)433.0179 upon commencement and conviction of work at least 24 hours In advance. All inspection requests for utility work must also be made 24 hours In advance. 8: Work affecting traffic flows shall be closely coordinated with the City Utilities Inspector. Traffic Control Plans shall be submitted to the Inspector for prior approval. 9: Flagging, signing and coning shall be In accordance with MUTCD for Traffic Control. Contractor shall provide certified flagmen for traffic control. Sweep or otherwise clean streets to the satisfaction of Public works each night around hauling route (No flushing allowed). Notify City Inspector before 12 :00 Noon on Friday preceding any weekend work, 10: Any material spilled onto any street shall be cleaned up immediately, 11: A $2,000 bond made out to the City of Tukwila for possible property damages caused by activities. 12: Clean and remove debris from City catch basin in and around hauling routes. Provide adequate temporary access as not to interfere with other vehicle movement or cause trucks to travel over curbs. All vehicles must make a complete stop prior to entering public right -of -way. 13: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities, 14: From October 1 through April 30, cover any slopes and stockpiles that are 3H:1V or steeper and have a vertical rise of 10 feet or more and will be unworked for greater than 12 hours, During this time period, cover or mulch other disturbed areas, if they will be unworked more than 2 days, Covered material must be stockpiled on site at the beginning of this period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. 15: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All disturbed areas of the site shall be permanently stabilized prior to final construction approval. 16: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection, doc: Conditions M102 -027 Printed: 03- 22.2002 ig City ofiukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 17: The Land Altering Permit Fee is based upon an estimated 300 cubic yards of FILL . If the final quantity exceeds this amount, the developer shall be required to recalculate the final quantity and pay the difference in permit fee prior to the Final Inspection. CONTRACTOR SHALL COORDINATE LOCATION OF WATER AND SEWER SERVICE CAPPING WITH CITY UTILITIES INSPECTOR TO ASSURE THAT WATER & SEWER SERVICE FOR THE METAL BUILDING THAT STAYS IN THE BACK IS UNINTERRUPTED. I hereby certify that I have read these conditions and will comply with them as outlined, All provisions of law and ordinances governing this work will be complied with, whether specified herein or not, The granting of this perm r performance •r perform presume to give authority to violate or cancel the provision of any other work or local laws regulating constructs ' Signature: /.,+r Print Name: es.„,iLe„ Date: OL doc: Conditions M102.027 Printed: 03.22.2002 t SEP 27 '01 11 :39AM TUKWILA DCD /PW CITY OFTUiI ✓ILA Permit Center 6300 Southcenter Boulevard, Sulfa 100 Tukwila, WA 98188 (206) 431 -3670 1(11" 11 11(.1 ()NI1 'Project Number: Permit N urhben .:'00,2 —0" 2 7 1�1i' 4 ��II 1t ('OILS Permit it Apl)Ii( Application and plans must by complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant! GuL.t_ .sir- -n•t-3T alcv .-....c.. Value of Construction; r1, Soo Tax Parcel Number: O O D J Q r V 1 t .. 0 5 Phone: (2tx. ) (oZ`! –$9uo .�. Fax 0: (24)6,) ro 14, 5_,,i r 2. w.. .w Site Address : / `/ u /51,/l. .1e-1J f 7 f1 1.,..E ri R• V �.• City Staatte//Zip :tom -Tt. t�..l�h_ _ I /� . 1 O 1 l O _ .-� City State /Zip: Sea ..E Lc, /.1 9gi2y Property Owner: GKtry =�...1u1TRti--l_ =rc. Street Address: 3 tt., a/ - 11 M /3 -...e So ...rnr Contractor: Phone: ( ) Street Address: City State/Zip: Fax 4: ( ) Architect: tV A Phone: ( ) Fax 0: ( )� Street Address: City State/Zip: Engineer: A Phone: ( ) Street Address: t ,. , City State/Zip: Fax II: ( ) Contact Person ' ✓I Grt. 1.10`i rEPI- Phone: (x''ts ) j,2 y _ 59 G 0 Street Address: �-+ 3 4 04 • i-rh+ ,1+•E J City State /Zip: 7E0.17 (.6, t..A will Fax 0: (zot, ) t ±S y )1. +.—. MISCELLANEOUS PERMIT REVIEW AND APPROVAL RE UESTED: O OE RILED OUT IY APPUCAN Description of work to be done (please be specific): I) ErnA I4-0 4SrC- ,a_ -- -4",.'- .'i.c.— 11323 51 will there be storage of fiammablecombustlble hazardous material in the building? ❑ yes ❑ no Attach list of slab and item loco I. on s .orate 8 1/2 X11 • • n.!Min uantltles & Material . t Date MUM ■ Above Ground Tanks ■ Antennas/Satellite Dishes • Bulkhead/Docks ■ Commercial Reroof ei Demolition ❑ Fence ❑ Manufactured Housin Replacement only ❑ Parkin; Lots C1.1 Retainin Walls 0 Tem,ore Facilities LI Tree Cutlina .ttt�tttt�.r... .ttttttt� . '...^--ir APPLICAN E UES FOR ISCELUN PUBLIC WORKS PERM, "C.11h.3nnelization /StrIpIng Curb cut /Acce`il/Sldowalk Flra t,00p/Hydrant (main to vaulHN: _ Sixe(s): ❑ Flood Control Zone ❑ Land Altering; 0 Cut yards 0 FIII_. cubic yards 0 sq. R,grading/clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer Its , ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt N_ Siza(s): 0 Deduct 0 Water Only O Water Meter /Permanent 1 ❑ Water Muter Temp N Sizels): Est. quantity; gal Schedule: ❑ Miscellaneous CI Mr—r7 Oversized Load /Hauling _MONTHLY SERVICE BILLINGS TO; Name: Ad re»: City / State/Zip: 0 Water 0 Sewer 0 Metro 0 Standby /11.10•INMNISINO- WATER M T R DEPOSIT /REFUN • ILLINC: Name; Phone: Address: City /State/Zip; Value of Construction • In ail cases, a value of constructlon amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current lee schedules. Expiration of Plen Review • Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 160 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accep 3 "N'9, HabwcpaU.th c Date applialrev- Application taken by: (initia sr SEP 27 '01 11 :40AM T .. ; ' •i • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN D BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED > ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT D STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) O Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit Is issued, unless the homeowner will be the builder OR submit Form H•4, "Affidavit In Lieu of Contractor Registration ". Iuildldg Owne► /Aut horlaedAgent If the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State of Wa,hin ton, a notarized letter from the property owner authorizing the agent to submit this Permit appllwtion and obtain the permit will be required as part of this submittal, I HERESY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO DE TRUE UNDER PENALTY OF PENURY RV THE LAWS OP THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, s Cily /Statealp: t t kd in%II 1r'I'I I( \ I I( r\ \tif) r,t r )i WM (rIr ► Id Ms MP Above Ground Tanks/Water Tanks, Supporti•d directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds Z:1 i'i is is Pi d II \\ Submit checklist No: M -9 Antennae /Satellite dishes Submit checklist No M -1 ti . Bulkhead /Deck Submit checklist No: M -10 a Commercial Reroof Submit checklist No: M -6 ®'' bemoITtion Submit checklist No M -3 Submit checklist No: M-9 Fences -Over 6 feet in Height El Land AlteringlGrading/Preloads Submit checklist No M -2 Submit checklist No: H -9 Cl Miscellaneous Public Works Permits 0 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M -5 rJ 0 Moving Oversized Load/Hauling '; t' Submit checklist No; M -5 Parkins Lots '' Submit checklist No M4 ffi Retaining Walls - Over 4 feet in height Submit checklist No; M -1 © Temporary Facilities Submit checklist No M4 0 Tree Cutting Submit checklist No: M -2 O Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit Is issued, unless the homeowner will be the builder OR submit Form H•4, "Affidavit In Lieu of Contractor Registration ". Iuildldg Owne► /Aut horlaedAgent If the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State of Wa,hin ton, a notarized letter from the property owner authorizing the agent to submit this Permit appllwtion and obtain the permit will be required as part of this submittal, I HERESY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO DE TRUE UNDER PENALTY OF PENURY RV THE LAWS OP THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, s Cily /Statealp: t t SEP 27 '01 11 :40AM TUKWILA DCD /PW CITY OF TUKWILA Permit Center 8300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3610 ri M-3 P.4 Submittal Checklist Miscellaneous Permits DEMOLITION ✓ .,,►i►• r)i(►►► ilc►,►liIf..►►►r►►t•• ✓ mommonimummum w►► ►h►►►(/ n►•,w►►►►! In a Distance between structures an • property lined Till with _fiend Exist ng landscaping IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Building location an • total square • • age Ell9 -t. is b • , I717r'i' f ' ' .. , !den water meter size • • . • I. 0, tlon o structures to • - removed III Temporary/permanent erosion control p an wm Two (2) cot con ours on rite la IIM - oints o access for • emolition ectly + es Limits o area to be • leturbed by • emolition act v ties MN • oats exls ng unitary e • e sewers an • po nts to be • u • • - . /ca • • ed at 'roil line II create exist ng water meters, dent fy ex s ng meters to • e removed by City Public Works staff. Identify existing water services to be co • • ad b demolition contractor. • entity ex a ng side re n: modify an • or capped Nft ooa ono s open 20 • or greyer, we an +s, we ercourses and their buffers • . /1(hI!(l(1► ).1/ 11f.►lo►►►•►►►r►►i., As • Woo A • Moment: Obtain approval from - uget Sound Air • ollut on Con ro gamy prior to proceeding demolition etrua ure to bee emaliehod Ie ov 6000 • , , =SPA checks s re ulnd ons ruction debris to be taken to a rls ao 1 n Count nformationa handout ava s et Permit Conteii Faun a ion must a com • ate remove N • an • onmen 0 Se o en for roe • entlal re • u roe a foI owin • con • 1 one • me : Pump mg. empty Till with _fiend 0 sm� entae /destro icap con Letter or receipt to veri>r above nditions hsve even met by -urn In service !dent' current sewer/water bil account num sr Hau n • r • ulrements must a mat If over tiO cubic ar s of matsris s to be taken to or from eite Ire Protect on - stem a emo issue • t rou . h Fire 6 e • artment An inspection prior to demolition will be made and again at mid-demolition and after work Is completed. Va2to1 apps\m•a.doc City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No,: 0005800011 Address: Suite No: Applicant: GULL INDUSTRIES, INC 15616 WEST VALLEY HY TUKW Receipt No.: R020000398 Initials: KAS User ID: 1684 Payee: BOBBY WOLFORD TRANSACTION LIST: Amount RECEIPT Permit Number: Status: Applied Date: Issue Date: M102 -027 APPROVED 03/04/2002 Payment Amount: 2,000.00 Payment Date: 03/21/2002 02:45 PM Balance: $231.00 Type Method Description Payment Check 27934 ACCOUNT ITEM LIST: Current Elute 2,000,00 Description Account Code BONDS /DEPOSITS 000/386.900 2,000.00 doc: Receipt Total: 2,000.00 70099 03/21 1716 TOTAL 2000.00 Printed: 03 -21 -2002 ig Parcel No.: Address: Suite No: Applicant: Receipt No,: Initials: User ID: Payee: City ofThkwila 6300 Southcenter 6L, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0005800011 15616 WEST VALLEY HY TUKW GULL INDUSTRIES, INC R020000404 KAS 1684 GULL INDUSTRIES TRANSACTION LIST! Amount Type RECEIPT Permit Number: Status: Applied Date: Issue Date: MI02 -027 APPROVED 03/04/2002 Payment Amount: 231.00 Payment Date: 03/22/200211103 AM Balance: $0.00 Method Description Payment Check 00204654 ACCOUNT ITEM UST! Description Current Pinta 231.00 Account Code BUILDING - NONRES INSP FEE - SME /SSS INSP FEE - UTILITY LAND ALTERING PERMIT FEE LAND ALTERING PLAN CHECK PLAN CHECK - UTILITY STATE BUILDING SURCHARGE 000/322.100 402/342.400 000/342.400 000/322.100 000/345.830 000/345.830 000/386.904 doc: Receipt 47.00 20.00 30.00 72.00 37.50 20.00 4.50 Total: 231.00 ' :7166 03/25 1716 TOTAL 231.00 Printed: 03.22.2002 INSPECTION RECORD Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT N (206)431 =3670 . ,1103,14....zill Type o In ti + n: ii, Date called S.tea In ru Ions; D a want= ,0 Requre jj/'1 I ouzo P '. •' f s Approved per applicable codes. " Corrections required prior to approval. COMMENTS► Inspecto Date: $47.00 REINSPECTION #LE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins +ection, Receipt No: Date: 1g INSPECTION RECORD f 02,.•• Retain a copy with permit ' Y INSPECTION NO, . PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-3670 Pro)ect: do. of Inspection: A r9s : i Date called: Specie Instructions: Date want +: a.m. ,m, Request Pone: Approved per applicable codes. ED Corrections required prior to approval. COMMENTS: (1101,41 Inspector: ( Pate: 44 1 4)/ $i47 +O0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins +ection. Receipt No: Date: INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 90 88 INSPECTION. RECORD Retain a copy with permit Pawn NO. (206)431-3670 Pro • _00 N i Type o Imp . et fx o A d est Date called: Specie lotructions: Date want. . Vi I a.m. Reques l'. 0 . ad el Cu lc ( P M‘) f4/9-51sPI Approved per applicable codes, COMMENTS: Corrections required prior to approval. 1 Date: 04741 REINSPECTION PEE REQUIRED, Prior to Inspection, fee must be paid t 6300 Southcenter Blvd„ Suite 100. Call to schedule reins • ection. Date: k. - . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, 1100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431-3670 Pro t: i el s Type , tin: INOLLIMIl ' " .4. Amu/no ariam 1,41 i Add : _ c e Date cal e: LIIIMPIMIMMV_4111111111111 Ce) 114 LINIIIMEMIIIMIIIIIII Specie instructions: Date want 11 Date: Requ ter: •/ --.41 o o: OL V '-`7.-) 0C) Approved per applicable codes. Corrections required prier to approval. COMMENTS: 311P ° )- Ak) Vaift4. INOLLIMIl ' " .4. Amu/no ariam , ■ r _Qui _ iebt l'Ait e IMATBIMMIFAIMIIMIrgr ' LEM LIIIMPIMIMMV_4111111111111 Ce) 114 LINIIIMEMIIIMIIIIIII inspector: kt) Date: 07.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reins ection. • p. x,. �w:>.;.. P; �o .,t:Y.['fi�*a'::�it;i}.�^?^S.v. Y..... ... INSPECTION RECORD Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 c(^` �� coq rogApproved per applicable codes, J Corre$1 dns equtr. ' pr or Co COMMENTS: ova Inspect Date: $47,00 REINSPECTION TEE REQUIRED. Prior to inspection, fce must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins'ection. Receipt No: Date: .t Vies Volley Highway t r rr —rrr r-� I Fi- r rr —rr-r rr -rr -r- Fi- r -r --r Fr ✓ rrr- r- r —rrrrr rr ✓ _ r = rrr"f_rr FE rr F —rr , -'r-rr rrrrr --� r r r' �-r,;, rrrr-r -r - rr-rr-r- cs r rrrrr -r 24 „.41 .cpp,962.71z* s„ N I A o u r gyp. lipitp210511.n. w APB tgii I ! ir sti kr! 1S' CO 0 am• e 0 12.8 I undare subject plans d adoptod tractor's By Date Perm FILE COPY tnnd that the Plan Check approvals are o errors and omissions and approval of os not outhorizo the violation of any code or ordinance, Rocoipt of con - copy of app oved plans acknowledged. CITY Of TUKWILA APPROVED MAR 2��{{ff0��r{ 20002 AS UtLDFNCG DIVISION ,ZTO 2 -ot7 1 10, t. «9 PARKING ANOYTIME B RIM ► 4.21 IE 20.51 (WIN N) IE 2).51 (12 "OUT E) GOOD ASPHALT PAVEMENT SIGN, NO PARKING ANYTIME wm N--TS UP♦ fIRASS PLAN I1ACK OF CURB WV IN HANDHOLE GRASS 0.41' N." OF LINE MtP J •P' TELEPHON! SERVICE 10'DAR 1JUNIPER N 88'04'43" W ,4:3.13,. f�ls��l�•�la�f�• 1ry4.FiFttk• es' ABANDONED 'ONI! STORY FRAME WITH DILL IIACIMENT BSMT. FF- 20.59' � M ''#" cog. ,p' gyp; N. EDGE OF COVERED WOOD ,yk� PORCH TELE. J -BOX, 5' UP WITH DROP TO GROUND GRASS CONC. �.r GRAVEL .M� 34 "CHE FFEE 25.28 K (2)4 "PVC PIPES" UP 0.4' (CLEANQUT: FROM ROOF DRAA: 1,� 17' HIGH MiETAL FRAME BUILDING WOOD FRAME GARAGE WITH CONCRETE FLOOR ELEC. METER UP 8' ELEC. METER WITH DROP 70 GROUND �M ' ti',k1 UP 5' CONC. ACCEIVEE"" CITY OF tux MAR 04 PERMIT CENT H PARCEL LINE IR 4 "CHERRY • SET TBM NO. 1 TOP NE BOLT FIRE HYD.; ELw25.74' te6 410. fy. STREET r ∎nuT y ti' 2-G S 40- Asphalt `:r SLOPE EAST: . REC. NO. 61 1 Gull Industries, Qrco Lonoccres Corner 15616 West Volley ighway Tu{- kwtlo. WA 9816E DEMO HOUSE AND GARAGE PARTIAL. SURVEY Date: Oct. 11. 2001 Scale: 1" = 20' 0" REVISION DATES: Sheet 2 of 2 N: City of Tukwila 6200 Southrenter Boulevard ltrkwlla, WA 98188.2599 (206) 433.1849 Fit0i i' ' E 1 C',= .4o-• _ , .t°AVe . DESCRIPTION... /30 /O0 Pr alvi out Balance :/11/170 Receipt /20/00 12/18/00 28 Watery /20/00 12/18/00 28 Sewer Sewage Current t 1alance NOTE: 1 CCF -100 Cubit) Foot -740 Gallons Treatment Charges Due Water Sewer . TNIB4PBRio i 1) d 11WW6111 2 2 CUSTOMER NAME : GU-,, L1 I I..IDUSTR I ES INC SEfiVICE LOCATION : 15. ~' W VALLEY HWY BILLING DATE : 12/31 /00 DUE DATEt -? l / 10/01 KEEP THIS PORTION FOR YOUR RECORDS ygVOUS "C Us IgNT _ CONSUMP TIO N (CCF ) 1942 1 942 tIArl _ 2 0 0 AMOUNT 41.50 41 .5OCR 12.00 10.00 19.50 41.50 41.50 �2 6 352a 5-0t3o3t3 — Baso t,) MESSAGESThe City of Tukwila is actively recruiting for its nip) Volunteer Trxsffi Safety Program. Duties focus primarily on monitoring handiclappu d prarki slots and tagging abandoned vehicles for impound. For information. plrs contact Roberta Nelson. Volunteer Coordinator, eat (20 +) 433 - •718: or e -r►ni t rnw!al sonOci . tukwi 1als.war. us 0 CD m APPROVED MAR 2 0 2002; AS NOILD Lt�tN DilltSt ., -- ...._.h • Agency Case No. 200101252 PUt3ET SOUND CLEAN AIR AGENCY • www.pscleanair.org Agency Use Only 110 Union Street, Suite 500 Seattle, WA 98101 -2038 ()TICE OF INTENT 4i 17afe Received OCT 1 5 2001 u Ageitcy_Usg that' A. Pro ect e: 1. d Asbestos Removal 2. Cl Asbestos Removal & Demolition 3. fig Demolition No Asbestos Removal Pro , erty Owner: C. Asbestos Contractor: R.+x . A • H ,&.• . t "7 r l.t„ : "rR ' • r 7 r : . Owner /CEO: Thormal S • tom Insulation: • lloiloAFumaco ins. • Duct Ins, • I ipo Ins. Matiirt : Address; A 1 �4St -os ►H es v'C-A b ,.... Ptti►� N 1U 0 Phone: Contractor lob No,: Ci . 6. • > 10,000 linear feet or > 50,000 s uaro feet of asbestos 10 Days State: 7. ii Emergency Asbestos Project or 011 Emergency Demolition Project Prior Notice Zi0; D. Site Address: Site Mans : cr: /5iell \•tiE Sr V • ►�. 9.2.1-7<.„... %I-t C Jh I Cit : it. tAsil.. Zi Local Phone: E. 1E721 Asbestor Starvey or No. of O Mat'i Presumed Structures: AHERA Building Inspector: Certification No.: F. Demolition Information: n Data Asbestos Survey was Conducted: 9 (1 0u rvey requ re r ore ono o on pri et • • $-'_ Was Friable Asbestos Identified? UYcs 17No Was Nonfriuble Asbestos Identified? ClYes CINo Attach a copy ditto survey, if nonf lnble asbestos is identified or if no asbestos is identified on survey. Lx Dntc: Stets: of 1, • Training Piro (List Fire Dept.) 2, ❑ Ordorod Demolition attach Will nonfrinble asbestos bo loft in place during demo? If yor, list typo and city. No. of Structures: Demolition stet emo Ilion contractor a maf fng a ruu on ck. Contractor: 6 WO We..fIetltir, .7.4411&14 At. co of • rde.11_, Yes ': No G. Asbestos Project --1 information: � Start Date: Com lotion Date: Work Days: M T W Th F Sit Su Flours: —"—'— Total • t . to bo Romovod: Linear Ft. S. wire Ft. Will all !liable asbestos !t i ' b • v..' • Yes Thormal S • tom Insulation: • lloiloAFumaco ins. • Duct Ins, • I ipo Ins. Othon • 1 R 10 Days Surfitoin { Mat'1: • Fire • roofing • Paints • Plaster • Textured Coalinga or Roofing WW1 Olher: Met:AS,rj° 4sii -'. • 5. • 1 000 • 9 999 linear feet or 5 000.49 999 s uaro feet of asbestos Misc. Mat'l • Cement Ad. • Comont Pipo • Friable Flooring $750 6. • > 10,000 linear feet or > 50,000 s uaro feet of asbestos 11. Asbestos/Demolition Project Categories: 1. Single•Family Residence: (Check box A & 13 for asbestos removal & demolition) A. O Asbestos Removal Project 13. -, Demolition Pro cot :1711ii3'.nrri;2 rt1. ,..,►.L.fitgL• • _ i • . RCPT. at').' ` A. Prior Notice 13, 10 Da s • : ' ofLndablo Pee Covers Asbestos Removal & Demolition • -• k • r • inolitio W No : ies • v 1 ' s•'ect 10 Da s 5150 3. • 10.259 linear feet or 48. 159 square feet of asbcstosJsee back) 10 Days $150 4. CI 260.999 linear feet or 160.4 999: • tare feet of asbestos 10 Da s $300 5. • 1 000 • 9 999 linear feet or 5 000.49 999 s uaro feet of asbestos 10 Da s $750 6. • > 10,000 linear feet or > 50,000 s uaro feet of asbestos 10 Days $2,000 7. ii Emergency Asbestos Project or 011 Emergency Demolition Project Prior Notice Twice Project Fee t do hereby c • that th information contained in this notification & supplemental data descr g t1Yy( bbcsst of my kaowled ; a m • & • mplete, Sfure CrrfrrTIORPhIA, Puget Sound Clean Mr Agency Form No. 1111NWPOyliti NtiV PEEWIT Ceara 4 Re resenting C U AS hiOitU fes y Use Onl Date Reviewed By Survey of Asbestos Containing Building Materials and Lead Containing Paint 15616 West Valley Highway Tukwila, Washington At the request of Dick Potter of Gull Industries, Dorothy L. Stansel and Charles H. Hale performed a pre - demolition inspection and sampling of materials at 15616 West Valley Highway, Tukwila, Washington. A total of 34 sanples were collected for asbestos and 47 lab analyses were performed on them. Six samples of paint were collected for lead analysis. The samples were collected from the house, the garage and the shop building at this location. In the case of non - manufactured building multiple samples were collected and analyzed according to the AHERA sampling protocols. The materials were submiitted to NVL Laboratories, Inc. at 4708 Aurora Avenue North, Seattle for asbestos analysis by polarized light microscopy and dispersion staining. The paint samples were analyzed by the same laboratory using atomic absorption spectrophotometric analyses. Those building materials containing asbestos at this house exist in four locations: 1) The elbows on the pipe insulation in the basement contain 25% Crysotilo Asbestos. 2) The straight pipe runs are insulated with 60% Cyrsotile asbestos. 3) The underlayer of the back porch linoleum contains 55% Chrysotile 4) There is 4% Chrysotile in the top layer of the house roofing. Prior to demolition, or moving this structure, the first three materials must be removed using Washington State Certified Asbestos Workers. The pipe insulation in the basement can be appropriately abated by glove bags, and the flooring on the back porch is a relatively small project. The exterior of both the house and the garage (other than the garage door) have been painted with lead containing paint. The limit of action set by both HUD and the EPA is 1 %.804the interior paint and the garage door paint is not of concern. It the paint is to be left on the building materials during demolition it will comprise significantly less that 1% of the waste. lithe house and/or garage is /are relocated for future use, it would be col, appropriate to follow the HUD guidelines for the abatement of the exterior lead paint. A�' T Thank you for the opportunity to be of service to Gull Industries. If there are questir, ar+ �4 fi concerns please feel free to contact me at 206- 325 -9933. ' '.,, 4,S14, 8OO2 RECEIVED '"G 4„•,. CITY OF TUKWII.A V76, N Submitted by: Doroth L. Stansel, C.I.H. MAR 0 4 2002 PERMIT CENTER e Asuestos Analysis of Building Matet ,uss 15616 West Valley Highway Tukwila, Washington Semite # Location % Asbestos Type Asbestos • $ 9-7-00-1 Elbow lagging in basement 1 1 25% . 25% • • Chrysotile Ch sotile 9- 7-00 -2 • Elbow lagging In basement 9- 7 -00 -3 •'Elbow leggin _ in basement 1 25% Ch sale 9- 7-00 -4 • Elbow legging in basement 1 25% Chrysotile 9- 7 -00 -5 • Pipe insulation, straight run , in basement 1 60% I Chrysotile 9 -7 -00-6 _ _ 9-7-00-7 9- 7 -00 -8 al a PI • e Insulation, straight run, in basement 1 PI • e Insulation, Straight run, in basement 1 _ 60% 60% $ Chrysotile Chrysotile Pink insulation above basement Ceiling 1 nd , 9-7-00-9 9- 7 -00 -10 9- 7 -00 -11 • MI MI Pink Insulation Above Basement Ceiling _ 1 Pink Insulation Above basement. Ceiling 1 nd nd Cloth insulated wiring in basement 1 nd � 9- 7 -00 -12 � Under layer of. bathrcom (found under #19 �n•aer _ d II 9-7-00-13 Under la e r of bathroom floor under # 20 a nd 2nd le er Sheet flooring from back porch i ji nd ndt6� 55% Chrysotile 9-7-00-14 2ndla er 9-7-00-15 Kitchen floor tile, light green nd nd 2nd loer 9- 7 -00 -18 Backin, for kitchen floor the n nd •.�.� 2nd layer Second la or of kitchen flooring nd nd __M9 9.7.00 -17 2nd la er Third layer of kitchen flooring nd nd 9- 7 -00 -18 2nd la er 3rd la er nd -0i- ,` 9.7 00.20 er newer y711ib Mi • • ii __ n a er nd Dar er o er Bat hroom floor ti a _ nd 29__ayer nd 9.7.00.21 Blown -In Insulation In attic nd 9.7.99.22 Blown -In insulation In attic nd 9.7 -00 -23 • Blown-In Insulation In attic nd Plaster from Inside hatch above cellar stairs ._na.. _ ___ _ �d 9-7-00-25 Plaster from tont hall closet _..... ndLLV _..W 9- 7 -00 -26 9-7-00-27 9- 7 -00 -28 111 1 Plaster from wall In front bedroom Plaster from closet In back bedroom Plaster from hallwa to front bedroom I nd nd nd 1 I 9- 7 -00 -29 II Top layer of roofing on house 1 4% nd L . n • r r Ch rsotile IIII 2nd la er I f, Roof Felt Under La er , U, 9- 7 -00 -30 11 9- 7 -00 -31 • Garage Roof 1, • b $ ,11) nd 9- 7 -00 -32 Sho • Bathroom border VAT 1 nd 2nd la er Mjj�►,` " nd 9- 7 -00 -33 Sho • Bathroom Center VAT .. ,• -� nd nd 1 1 • 2nd la er ` ' 9- 7 -00 -34 Sho • Roof Insulation _; , , r- ; .,t . nd r•, F TitIONII A MAR 0 4 2002 g6 ti Op November 27, 2000 Gull Industries Attn: Dick Potter P. 0. 13ox 24687 Seattle, WA 98124 Re: Asbestos Abatement Services at: Dear Mr. Potter: TLN Environmental, Inc. 9221 Roosevelt Way NE Seattle, WA 98115 Phone: (206) 523 -4441 Fax: (206) 522 -4099 WA St. Cont.# TLH ENI•000JJ 15616 West Valley Highway Tukwila, WA 98188 TLH Job # L -171 With reference to the above property, this is to certify that we have removed and properly disposed of all asbestos containing materials, per the contract, accessible without demolition. All work was performed and completed in accordance with existing Federal, State and Local regulations. Air clearance samples have met or exceeded EPA and OSHA standards and all areas are safe for re -entry by unprotected workers and the general public. If you require any further information, please do not hesitate to contact me. Sincerely, TLH ENVIRONMENTAL, INC, ., Meg Secrist CiTY OF TUKWILA APPROVED MAR 2 0 2002 AS I9uIcU ettILDNG DiVISION RECEIVED CITY OF TUKWILA MAR 0 4 2002 ,ERMIT CENTER "MucKS com-e op-) Earf S. /5t, -to lead 4201'1 On /11€13-oh eicite WeSt IQPj W Ato r41-t, SOU iv-c( N.14 Actuay ct), V. 1q, leo RECEIVED MAR 14 2003 Pu m 7.;?(A-i< / ?ov'TC. 60' 196 C / Sr6 /47 1.) , Va lle y /fz?,4.r JO Z- 02 4,0•41AC ve S INN.y APPrewrn nr r pi 'Pi !c WORKS DATED . 3//402 03/11/2002 09 :33 FAX 200 824 5412 To: GULL (INDUSTRIES_ Gull Industries, Inc. Construction Department FAX TRANSMITTAL 1.800.86 6.4856 (206) 6245900 Pax (200) 624 -5412 Joanna Spencer Development Engineer City.of Tukwila Public Works Department Fax: (206) 431 -3665 2001 From: Dick potter Dsto; March 8, 2002 Numbs of Pags: Projcr Demo of House & Garage 0 15616 West Valley 'Highway L+MI02 -027 ########################################### # # # # # # # # # # # # # # # ### # # # # # # # # # # ## In response to the questions contained in your fax transmittal of this date. 1. Yes. The existing metal building, which is not being demolished at this time, has water and sewer service. 2. No. Our records show both structures share a single utility account and the water service. We have no information which would indicate a separate water or sewer connection for the metal building. 3. Estimated yardage to backfill foundation - 300 cy. Area of house - 1,323 sf Basement Finish Floor m 20.59 Calculated Basement Subgrade m 20.09 Average Existing Grade m 25.65 Average Depth of fill m 6 ft 1,323 x 6 /27 - 294 cy 4. The demolitidn contractor will provide the information, insurance and bonds for the hauling permit. The contractor is: Bobby Woolford Trucking & Excavation 22014 West Bostian Road Woodinville, WA 98072 Phone: (425) 827 -7530 Fax: (425) 486 -6613 Contact: Bruce White 5. x am forwarding your request to use Nelson Place as access to Hobby Woolford. T would expect they would prefer to use either Nelson Place or 1560 and avoid using the West Valley Highway as the access point, IS 02- 02,7 n: Vickie McLean At: Jones & Mitchell To: Joan la Spencer Fax#: (509) 838.3501 Date: 3/13/02 01:31 PM Page 2 of 2 ACORD. CERTIFICATE OF LIABILITY INSURANCE CSR WM BOBBY -1 OATS(MBOOrr1) 03/13/02 OR BELOW. FOR THE POLICY PERIOD TO WHICH THIS THE TERMS, EXCLUSIONS POL • Y 1 P TION l , 03/02/03 PRObuc,R Jones i Mitchell PO Sox 2786 Spokane NA 99220 Phone: 509- 838•3301 Pax: 509-838-3511 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND ALTER THE COVERAGE AFFORDED BY THE POLICIES INSURERS AFFORDING COVERAGE INIUR,b . Bobby Wolford Trucking i salvlge, Inc. 220 di West Einstein Woonville WA 9007 _ INAURERA Liberty Northwest INSURER 8 EACHOCCuOSENCS w9uaea e mgOAMAOE( ors. Ate) Mauaaab I49114E0 O CLAMS MADa fl occuR COVERAGES THE POLICIES OF INSURANCE LISTED ANY REQUIREMENT, TERM OR CONDITION MAY PERTAIN, THE INSURANCE AFFORDED POLICIES. AGGREGATE LIMITS SHOWN BELOW HAVE BEEN ISSUED TO THE INSURED OP ANY CONTRACT OR OTHER DOCUMENT BY THE POLICIES DESCRIBED HEREIN MAY HAVE BEEN REDUCED BY PAID CLAIMS. rover NUMSSN NAMED ABOVE WITH RESPECT IS SUBJECT TO ALL C S IQ w! 04 ► 03/02/02 FOR THE POLICY PERIOD TO WHICH THIS THE TERMS, EXCLUSIONS POL • Y 1 P TION l , 03/02/03 INDICATED. NOTWITHSTANDING CERTIFICATE MAY BE ISSUED AND CONDITIONS LIMITS OR OF SUCH 11,000 000 Tvrr OP *simmer A OINr*ALLMrKITY COMMEaC04 0tNE19A{.LmUTY CPA000137400 EACHOCCuOSENCS i mgOAMAOE( ors. Ate) t 100 000 CLAMS MADa fl occuR MPnom( BB b!tW) t 5 000 Pt0§044LAAMINJURY s 1 000 000 _ 00111A1,A0ORaOATa S 2 000 000 0I41 —I AOORIOATII UNTAPP1.4111 a PcUCY n lC ! 1 LOC PPOOUCTS • COMPtOP ASO t 2 000 000 A AUTOMWSI.I WWLITY ANY AUTO ALL OWNED AUTOS ALL RCNSOUL1DAUTOSi HMO AUTOS NON+OW 40 AUTOS CPA000137400 03/02/02 03/02/03 c 111""14) x! I 1,000,000 Y _ Mer.s I ) v SOQLr wIA/RY (PN /ceaMN) t — .— .po. ATY OAMA00 (PN KCi .11 t OARA08 LMNLITr ANYAVTO ~•— A1110 ONLY . !A ACCIDiNT t O►HeRTw IA ACC t AUYO ONLY A00 L OMONO LWINTY OCCUR E CLAM WOO DtDUCY &i ReT!NT10N 1 iACH OCcuRRiNGg Si AQGn aATi t 1 ` S ____ 1 A�� WO MINIM M OOMPINIAYION AND iMrLOrrlwLwlulr EMPLOYERS LIAR STOP GAD 03/02/02 03/02/03 eLeAcio.ccoaNY s 1 000 000 e L mem • CA EMPLOYEE 1 1 000 000 0 panne. POUCYOAT 1 1 000 000 OWINN ONCNPTION OF OPORATIONOILOGATIONONMMGLOOIrMGLVMONO ADM SY ONDORMWNTINOOML PROVIi10NO Certificate holder nosed as additional insured as respects operations of the named insured fox certificate holder. w CERTIFICATE HOLDER ADDITIONAL INIUMO; IN$URSR LOTTPN CANCELLATION TUKWILA City of Tukwila 6200 Southaenter Blvd Tukwila WA 98186 SHOULO ANY OF THI ANOVI D$$CRIU$O POLICIif ri CANCILL$0 ¥$FORM THS 4XPIMTION OATS TtesSOF, THI ISSLANO IN *URiR WILL /NOSAYOR TO MAIL ..30 DAYS WRITTIN NOTICS TO THi CIRTIFICATI HOLOIR NAMIO TO THI LIFT, RUT FAIWRr TO 0010 SWILL IMPOfi NO OBLIGATION OR LWILITY OF ANY KINO UPON THS IN$URIR, IT$ AOINT5 OR RUPRISSNTATNI$. AUTHORIZED RMPRISSNTATIV$ Robert S. McWilliams ACORD 254 (7197) MI02 Q7R0 CORD RA ION 1888 Og y �� ,4:$.A”2M4.U0 ($V7 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL .REGZST., # CCOY ; .3 BOBBYWT088CC. EFFECTIVE "DATE . ..... , . •.. t. EXP. DATE 12/01/2003 '02/03/1992 BOBBY WOLFORD,.TRKNG &,SLVG INC 22014 WEST BOSTIAN AD WOODINVILLE WA 98272 Detach And Dhplay Certificate --% /-f,iawv4 Co/v7g6craK. NIOZ- 027 F�: Ciy of Tukwila Steven M. Mullet, Mayor Department of Public Works James E Morrow, RE., Director May 2, 2002 Bobby Wolford Trucking & Salvage, Inc. 22014 West Bostain Road Woodinville, WA 98072 Subject: Gull Industries, Inc. Permit # MI02 -027 Hauling Bond To Whom It May Concern: Enclosed please find check # 13111 In the amount of $2,000.00. This check is reimbursement for the above referenced Hauling Bond, If you have any questions, please feel free to call me at (208) 433 -7184. Sincerely, u.(.)M.Lt Laurie Werle Permit Technician enclosure P;L utio•PonniWond rolaasa 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -433 -0179 • Fax: 206.431.3665 TO: FROM: DATE: SUBJECT: City of Tukwila Department of Public Works Steven M. Mullet, Mayor MEMORANDUM Laurie Anderson Laurie Werle t() 04/16/02 Gull industries 15616 West Valley Highway Permit No.: M102 -027 James F Morrow, P.E., Director Please draw a check in the amount of $2,000.00 (two thousand dollars) to be payable to Bobby Wolford Trucking & Salvage Inc. This check is reimbursement for a $2,000,00 check deposited by Bobby Wolford Trucking as part du Hauling Permit Package. The project has been completed and finaled by City Inspectors on 04/10/02. Thank youl P;Laurie•PermidBond release 6300 Southcenter Boulevard, Suite ##100 • Tukwila, Washington 98188 • Phone: 206.433.0179 • Fax: 206.431.3665 • ?RMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI02 -027 PROJECT NAME: GULL INDUSTRIES, INC SITE ADDRESS: 15616 WEST, VALLEY H.IGHWAY.. DATE: 3 -04 -02 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: 8uil i ?vision Pulic ork AlAJU Fire Pro ('_f Structure Plan i iv inn Permit Coo, d nator DETERMINATION QF CQMLL TE__ENESS: (Tues., Thurs.) Complete er Comments: Incomplete DUE DATE: 3.05 -02 Not Applicable ❑ P,rmlt Center Use Only INCOMPLETE LETTER MAILED :i_. Departments determined Incomplete: LETTER OF COMPLETENESS MAILED: Bldg ❑ Flra ❑ Ping 0 PW ❑ Staff Initials:,__ TUES/THURS ROUTING: Please Route (r Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE:,_„ 4.0212 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping D PW ❑ Staff Initials: Documents/routing slip.doc 2.24 -02 PERMIT COORD COPY erg I t OR } PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI02 -027 PROJECT NAME: GULL INDUSTRIES, INC SITE ADDRESS: 15616 WEST VALLEY HIGHWAY 0 DATE: 3 -04 -02 Original Plan Submittal Response to Incomplete Letter____._________ Response to Correction Letter #_ Revision # After Permit Is Issued DEPARTMENTS: Building Division ) Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ QETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete 0 DUE DATE: 3-05-02 Not Applicable ❑ Permit Confer Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:_ Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials :_ TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ig REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 4.02 -02 Approved ❑ Approved with Conditions ,k1 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:, Documents/routing siip,doc 2.1802 4s p PERMIT NO.: M Io2.-.ozl BUILDING PERMITS INSPECTIONS ❑ 1 Progress inspection Status ❑ 2 Pre-construction ❑ 3 investigation ❑ 4 OK to Occupy ❑ S Remove Stop Work Order ❑ 6 Follow-up ❑ 7 Pre-Move Inspection ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 70 NLEA Inspection/Modular Struct 71 Mobile Nome Tie Down Insp 72 Marriage Lines 90 Rested 95 Footing Drains ❑ 100 Foundation Footings ❑ 200 Foundation Walls ❑ 250 Foundation insulation ❑ 300 Concrete Slab /Slab Insulation 350 Crawl Space 400 Shear Wall Nailing 450 Plywood Wall Sheathing 500 Roof Sheathing Nailing 525 Plywood Deck Nailing 550 Exterior Wall Sheathing 600 Masonry Chimney 610 Chimney Installation/All II Types 700 Framing 750 Roof/Ceiling Insulation 800 Floor Insulation 801 Wall Insulation 802 Exterior Roof Insulation 803 Closing Inspection ill S Lighting and Controls 00 Suspended Ceiling 000 Interior Wallboard Fastening 001 Exterior Wallboard Fastening 110 Pre•ttilove Inspection 11 S Motor Inspcction 120 Prc•Dcmo 140 Prc•rcroof 400 Final -Fire 700 Final•13u1ld(ng 900 Final•Rcroof 100 Situ Visit 000 Special•Concrete 001 Special•Bolts In Concrete 001 Special-Mom/Resist Cone Frame ❑ 4003 Spccial•Rcinf Steel Prestress (_ 4004 Special-Welding 4005 Special-High-Strength Bolting 4006 Special-Structural Masonry 4007 Special•Reinf Gypsum Concrete 4008 Special-Insulating Cone Fill ❑ 4009 Special-Spray Fireproofing ❑ 4010 Special-Piling, Piers, Caissons ❑ 4011 Special•Shotcrete ❑ 4011 Special-Grading, Excav /Fill ❑ 4013 Special-Retaining Wall ❑ 4014 Special•Panels ❑ 4015 Special•Smoke Control System TENANT NAME: CONDITIONS ❑ ❑ ❑ 0001 0002 0003 0004 0005 0006 0007 0008 0009 0010 0011 0012 0013 0014 0015 0016 0017 0018 41140 , 010146e. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division Plumbing permits shall be obtained through King Co Electrical permits obtained through L & 1 All mechanical work shall be under separate permit All permits, insp records & approved plans available All structural concrete shall be special inspected All structural welding shall be done by WAIO certified inspector MI high strength bolting shall be special inspected Bolts installed in concrete shall be special inspected When special inspection is required...notity Tukwila Building Division The special inspector shall submit a final signed report Any new ceiling grid and light fixture installation Partition walls attached to ceiling grid Readily accessible access to roof mounted equipment Engineered truss drawings & gales shall be on site Any exposed insulation backing material shall have Subgradc preparation including drainage, excavation A statement from the rooting contractor verifying fire retardant class of roof 0019 All construction to be done in conformance w /approved plans 0020 Structural observation shall be provided for this project 0021 All food preparation establishments must have King Co 0022 Fire retardant treated wood shall have flame spread of 0023 Notify Building Division prior to placing any concrete 0024 MI spray applied fireproofing shall be special inspected 11025 All wood to remain In placed concrete shall be treated *10026 All structural masonry shall be special inspected 0027 Validity of Permit 0028 Ruck storage requires separate permit 0 0 ❑ ❑ 0030 ...,No occupancy of building until final Insp by Bldg Div 0031 ..,Comply with requirements oI'TMC 16,04 0032 Remove all weeds, concrete, stone foundations, flat concrete 0034 Removal of septic tanks require approval and compliance with King Co I lcalth Dept. Contact PW Div to obtain Insp for water /sewer connect Manufacturers installation instructions required on site 0035 0036 0038 A C o10 will be required for this permit 0039 Final approval for all Ti w /in the limits attic SC Mall 0040 All construction noise to he in compliance with 8,2 TMC 0041 Ventilation is required for all new roams & spaces 0041 0043 0044 0045 .Fuel burning appliances .Appliunces, which generate Water heater shall be anchored ..Reroof "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" Plan Reviewer: Permit Tech: Date: Date: 3 • 102' PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI02 -027 PROJECT NAME: GULL INDUSTRIES, INC SITE ADDRESS: 15616 WEST VALLEY HIGHWAY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DATE: 3 -04 -02 DEPARTMENTS: Building Division ❑ Fire Prevention Public Works ❑ Structural Planning Division Permit Coordinator IMERMINATtON O QMMELE?ENES5: (Tues., Thurs.) Complete ❑ Comments: Incomplete DUE DATE: 3 -05-02 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route ❑ Stru ral R view Required 0 No further Review Required ,jaN REVIEWER'S INITIALS : �,. � DATE: APPROVALS : DUE DATE: 4- 2 -02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bidg ❑ Fire ❑ Ping ❑ PW ❑ • Staff Initials: Documents/routing slip.doc 229.12 It �t PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI02 -027 . .. DATE: PROJECT NAME: GULL INDUSTRIES INC SITE ADDRESS: 15616 WEST VALLEY HIGHWAY X Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued 3 -04 -02 DEPARTMENTS: Building Division ❑ Fire Prevention ❑ Public Works ❑ Structural Planning Division x ❑ Permit Coordinator ❑ DETERMINATION O_F C P_LETE ESS: (Tues., Thurs.) Complete 46 Comments: Incomplete ❑ DUE DATE: 3.05.02 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: OF COMPLETENESS MAILED:_ Departments determined Incomplete: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ' REVIEWER'S INITIALS: @, - DATE: 3-5-oz. APPROyALS QR CO REyjIONSt DUE DATE: 4 -02 -02 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: . Permit Center Use Only CORRECTION LETTER MAILED; Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials. Pocumentshouting slip.doc 2.2g -02 a vs ea } PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI02 -027 PROJECT NAME: GULL INDUSTRIES, INC SITE ADDRESS: 15616 WEST VALLEY HIGHWAY DATE: 3 -04 -02 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural 0 Planning Division ❑ 0 Permit Coordinator ❑ DETERMINATION QF COMM.ETENESS: (Tues., Thurs.) Complete ❑ Comments: Incomplete DUE DATE: 3 -05 -02 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED:, LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff inlilals :, TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required ❑ DATE: 3 `03..`p2' APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Approved with Conditions 54. DUE DATE: 4.02 -02 Not Approved (attach comments) ❑ DATE: , , 15 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentshaul na slip.doc 2.28-02 } DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL , , , , REGIST ., # EXP. DATE CC01 , `,BOBBYWT088CC° .12 /01/2003 EFFECTIVE"DATE.;.; 02/03/1992 BOBBY WOLFORD ..TRKNG &.SLVG INC 22014 WEST BOSTIAN AD WOODINVILLE WA 98272 '�— Detach And Di.pluy Ceniticuie H*WN6 CoN772.09.c7o4. i§ REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. #. EXP. DATE ' CCO1 . GULLOC *16SES 12/13/2003 EFFECTIVE DATE 01/10/1984 GULL OIL.COMPANY PO BOX 24687 SEATTLE WA 98124• Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES IV1 10 ao3?