Loading...
HomeMy WebLinkAboutPermit MI02-108 - SOUTHCENTER WEST BUSINESS PARK - REROOFSOUTHCENTER WEST BUSINESS PARK 1177 ANDOVER PK W BLDG B EXPIRED 01 -20 -03 M102 -108 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049097 Address: Suite No: 1177 ANDOVER PK W TUKW MISCELLANEOUS PERMIT Permit Number: Issue Date: Permit Expires On: M102 -108 07/23/2002 01/19/2003 Tenant: Name: SOUTHCENTER WEST BUSINESS PARK Address: 1177 ANDOVER PK WEST, BUILDING B Owner: Name: CALWEST INDUSTRIAL PROP Address: C/O DELOITTE & TOUCHE LIP, 2235 FARADAY AVE #0 Contact Person: Name: RON HAIGHT Address: 491015 AV NW, SEATTLE, WA Contractor: Name: HAIGHT ROOFING COMPANY INC. Address: P.O. BOX 70150, SEATTLE, WA Contractor License No: HAIGHRC269QK Phone: Phone: 206.784.8414 Phone: 206 784.8414 Expiration Date: 05/01/2004 DESCRIPTION OF WORK: TEAR OFF EXISTING ROOF AND REPLACE WITH NEW ROOFING MEMBRANCE ONLY. Value of Construction: Type of Fire Protection: Type of Construction: $181,293.70 Fees Collected: $2,401.87 Uniform Building Code Edition: 1997 Occupancy per UBC: Public Works Activities: Curb Cut/Access/Sidewalk/CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: N Land Altering: N Landscape irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: Channelization / Striping: Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Private: * * Continued Next Page ** Public: doc: Miscperm M102.108 Printed: 07.23.2002 et IR City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Permit Center Authorized Signature: Date: _ / 2 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construct • or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection, doe: Mlscperm M102-108 Printed: 07-23-2002 City of Tukwila Department of Community Development / 6300 Southcenter SL., Suite 100 / Tukwila, WA 98188 / (206) 4314670 Parcel No.: 3523049097 Address: 1177 ANDOVER PK W TUKW Suite No: Tenant: PERMIT CONDITIONS SOUTHCENTER WEST BUSINESS PARK Permit Number: Status: Applied Date: Issue Date: M102 -108 ISSUED 07/16/2002 07/23/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division, 3: AD permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction, These documents are to be maintained and available until final inspection approval is granted, 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit, The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid, I hereby certify that I have read these conditions and will comply with them as outlined, All provisions of law and ordinances governing this work will be complied with, whether specified herein or not, The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work, Signature: Print Name: Date: /'13 '42 L'§ doc: Conditions M102.108 Printed: 07-23-2002 CITY OF T 'KWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: R ~1-111- l!(l ()NI \ M D8 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. 4e y��• Applications will not be accepted through the mail or facsimile. Project Name/Tenant: Southcenter West Business Park Value of Construction: $ 181,293.70 Tax Parcel Number: Site Address : City State/Zip: 1611 -1177 ANdover Park West Bldg "B" Tukwila. WA 98188 Property Owner: CalWest Holding. LLC C/O Equity Office Phone: ( ) 425 - 467 -1640 Street Address: City State/Zip: 500 -108th Avenue NE, Suite 240, Bellevue, WA 98004 Fax #: ( ) Contractor: Haight Roofing Company, Inc. Phone: ( ) 206 -784 -8414 Street Address: City State/Zip: 4910 - 15th Avenue N.W., Seattle WA 98107 Fax #: ( ) 206 -784 -1058 ik $KiMX Consultant D 7 Consultin• Inc. Phone: ( ) 949 - 955 -2777 Street Address: City State/Zip: 4101 Westerl Place Suite 110 Newport Beach CA 92..1 Fax #: ( ) 949 - 955 -2829 Engineer: Phone: ( ) Street Address: , _ City State/Zip: Fax #: ( Contact Person: Ron Haight Phone: ( ) 206- 784 - 8,14_ Street Address: City State/Zip: 4910 - 15th Avenue N.W.. Seattle. WA 98107 ...._ Fax #: ( ) 206- 784 -1058 MISCELLANEOUS`PERMIT REVIEW AND APPROVAL RE UESTEDs fTO SE FILLED OUT EYAPPLIC4NT) Description of work to be done (please be specific): Tear -Off Existing roof and replace with new roofing membrane only. Will there be storage of flammable/combustible hazardous material in the building? ❑ yes ® no Attach /lit of materials andsst-o�r■a�e location on xe agate 8 1/2 X 11 a er lndicatin uantltles & Material Sate& Data Sheets 71 Above Ground Tanks U Antennas/Satellite Dishes J Bulkhead/Docks Commercial Reroof ❑ Demolition ❑ Fence ❑ Manufactured Housin •Replacement only ❑ Parkln8 Lots ❑ Retalnln WTI. ❑ Tom ora Facilities Tree Cuttini APPLICANT RE VEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS In Channelizatlon/Striping ■ Curb cut/Accoss/Sidowalk ■ Fire Loop/Hydrant (main to vault)N: Size(sh ❑ Flood Control Zone ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft,grading/clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer I: ❑ Sower Main Extension —5 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt N Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent N Sizo(s): ❑ Water Meter Temp N Size(s): Est, quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling MONTHLY SERVICE.BILLINCS TO: Name: Phone: Address: City /Sta /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Phone: Address: City /Sta e/Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review • Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 1 80 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 7 -1 -u 1- 9/9/99 miscpnN. doe Date application expires: .4pplic tion taken by: (initials) ,Ct 0' All AfIS((LLANFOUS PI t'" .'T APPLICATIONS MUST B£ SUBMIT _., WITH THE FOLLOWING: D ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER i City of Tukwila 6300 Southcenter 8L, Suite 100 / Tukwila, WA 98188 / (206) 431 -3870 Parcel No.: 3523049097 Address: Suite No: Applicant: SOUTHCENTER WEST BUSINESS PARK 1177 ANDOVER PK W TUKW RECEIPT Permit Number: M102 -108 Status: PENDING Applied Date: 07/16/2002 Issue Date: Receipt No.: R020000989 Initials: KAS User ID: 1684 Payment Amount: 944.42 Payment Date: 07/17/2002 09:19 AM Balance: $1,457.45 Payee: HAIGHT ROOFING CO TRANSACTION LIST: Amount TYPI Method Description j Payment Check 21942 ACCOUNT ITEM LIST: Current Pmts 944.42 Description Account Code PLAN CHECK - HONRE8 000/345.030 944.42 Total: 944.42 35 f ; Ds;fi i t 1716 TOTAL 1000.04 doc: Receipt Printed: 07.17.2002 Aao) City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049097 Address: 1177 ANDOVER PK W TUKW Suite No: Applicant: SOUTHCENTER WEST BUSINESS PARK Receipt No.: R020001025 Initials: SK5 User ID: 1165 Payee: HAIGHT ROOFING TRANSACTION LIST: Amount Typo RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Method Description Payment Check 21948 ACCOUNT ITEM LIST: Description Current Pmts 1,457.45 Account Code BUILDING - NONRES STATE BUILDING SURCHARGE 000/322.100 000/386.904 1,452.95 4.50 M102-1 00 APPROVED 07/16/2002 1,457.45 07/23/2002 10:35 AM $0.00 Total: 1,457.45 !37-44 07/25: 17/6 TOTAL jAL 29i4 w 90 doc: Receipt Printed: 07-23-2002 INSPECTION RECORD Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southeenter Blvd, #8100, Tukwila, WA 98188 (206)431 -3670 Pro ect: Type o Ins : eetlon: 'Y A . rots: �s / 7 G.i ' G : r�'G+ l'4 f ff! Date called: ,r`,+� 7`t, �j ... 4 Specks Instructions: Date wanted: a.m. e .m. Requestey;/X PannC11, pee) -/9,0„, ;;d Approved per applicable codes. Corrections required prior to approval. COMMENTS! i *47.00 REINSPECTION ill REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule rein pection. Date: Receipt No: 1 0 °o REViSIONS NO CHANGES SHAD. BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OF TUKWILA BUILDING DIVISION. NOTE REVISIONS WILL Mauna A NEW NMI 8U8Mfl1AL AND MAY INCLUDE ADDTT OVAL PLAN REM FEE& iq sS p !! a Baga g.1 32 a)/ 4)8 ..oaEA) a n) '0 O •., o .0 O .$1°N MOO 3111 a FINIMINIMI a 0 rt) / c, N 0 4 mss, 1161 -1177 ANDOVER PARK W. 2002 ROOF REPLACEMENT • BUILDING B D7CONSULTJNG Ih4C. 'RF,E_F MANAGEMENT 4101 Westerly Place. #110 Newport Beach. CA 92660 SEATTLE, WASHINGTON SOUTHCENTER WEST BUSINESS PARK KENT, WASHINGTON RENAME OI11PVO2 DATE MUM DRWN BY: MBL 412t1OP M4- CONVENTIONAL M4 -XHA 4 -5 rotioitiOtetitifif p rxZ tuft tttetr_�t I Dock Typo - Uninsulated _ Rating Slope in 12" _ BASEMEELEMOMFAt Mech. See Gen. Req. Fast. Asphalt Depending on Deck Typo Change Spec Number to Read* Combust, /Naliable Wood N/A A 2" Hot Asphalt M44/1-XHA•H F.2 Structural Concrete N/A Structural Concrete A 2" C.7 Lightweight Concrete X M4•CU•XHA -H Lightweight Concrete N/A M4•LI•XHA•H Metal A 2" N/A Metal N/A Structural Wood Fiber A 2" F.8 N/A Structural Wood Fiber N/A A 2" F.6 Hot Asphalt N/A Gypsum N/A 2" • i as. au: F.4; F.7 contra .. ac cons • oration. Hot Asphalt an. o er aener: M4- PI•XHA•H tonics.annmlt \tCn N/A Precast Slabs N/A N/A Deck Type - Insulated Rating Slope in 12" Insulation Attachment See Gen. Req. Roofing Attachment to Insulation Depending on Deck Type Change Spec Number to Read' Combust./Nallable Wood A 2" Hot Asphalt M44/1-XHA•H F.2 Structural Concrete A 2" F.4 Hot Asphalt M4•CI•XHA -H Lightweight Concrete A 2" F.5 Hot Asphalt M4•LI•XHA•H Metal A 2" F.3 Hot Asphalt M4•MI =XHA -H Structural Wood Fiber A 2" F.8 Hot Asphalt M4•SI•XHA•H Gypsum A 2" F.6 Hot Asphalt M4•GI•XHA -H Precast Slabs - e Ar n a. nr C mere - eau rements: A - esoons 2" • i as. au: F.4; F.7 contra .. ac cons • oration. Hot Asphalt an. o er aener: M4- PI•XHA•H tonics.annmlt \tCn Refer to Tab 11 for Products and Associated Materials information. Refer to Tab 6 for Execution Specifications. Refer to Tab 7 for Flashing Details. • Change last Character (H =Hot Asphalt): S =SEES Hot Asphalt The same material must be used to attach the membrane to insui9tiob4rU i Li) Fay .; 11t93.MAUSW JUL 19 2002 end Johns Manville Description E'NRG'Y 2 is a rigid roof insulation board composed of a closed cell polyisocyanurate foam core bonded in the foaming process to uni- versal fiber glass reinforced facers, E'NRO'Y 2 meets the physical property requirements of ASTM C 1289 and Federal Specification HH- I.1972/Gen and HH -I. 1912/2. E'NRO'Y 2 specialty products are also available as tapered panels, pro -cut miters and pro -cut crickets. Use E'NRO'Y 2 provides high thermal insulation value over metal, nail- able, and non•nailablo roof decks in built-up, modified bitumen and single ply membrane roofing systems, It may be applied using hot bitumen, cold adhesives or mechanical fasteners, The universal facer on the top and bottom side provide a suitable surface for mechanical attachment to a structural dock as wall as a suitable surface to apply hot asphalt or cold adhesives. E'NRG'Y 2 has boon rated in Factory Mutual 1A•00 and 1A -90 fire and wind - resistant systems for BUR, modified bitumen and single ply systems in specific constructions::It has been classified by Underwriters'', Laboratories, Inc" as an approved roof insulation In many Class A roof constructions and Roof /CNitng hourly fire•rated assemblies, and is classified by Underwriters Laboratories Canada, Prrlriiirt5 E'NRG'Y 2,M JM also supports MICA Bulletin #9 in recommending that a cover board of Fosco Board, Fiber Glass Roof Insulation or W Rotro -Fit Board be installed over foam insulations in hot membrane systems, Advantages • High thermal efficiency • Universal facer that Is compatible with BUR, modified bitumen and single ply membrane systems • Complies with EPA requirements • Moots Clean Air Act Amendments of 1990 Typical Physical Properties Values Test Method Water Absorption, % by 1,0 max ASTM C 209 Volume - 2 hrs. Dimensional Stability Change; 7 days 158°F (70'C), 90.100% RH Lengthwise <2% ASTM 0 2120 Crosswise <2% Compression Resistance" 10% Consolidation-poi (kPo)20 (138) nom ASTM D 1021 Moisture Vapor Transmission" <1 perm ASTM E 90 (57.5 ng /(Pa'a•m') Flame Spread" 25 max ASTM E 84 Service Temperature •100 to 200 °F (•73° to 93 °C) *Also amiable in 24 psi 1111 OMsl. "Few core only. For Use Over Metal Decks The minimum thicknesses of E'NRG'Y 2 insulation over motel docks are as follows: Width of Rib Opening Thickness of Insulation tMinimuml Upto23/4'1 Upto3' /4' (67 mm) (86 mm) 1.0" (25 mm) 1.2' (30 mm) Up to 4'/i' (111 mm) 1,34133 mm) Sizes E'NRG'Y 2 is available in 4' x 4' (1.22 m x 1.22 m) or 4' x 8' (1.22 m x 2.44 m) boards (other sizes available by special request) and in thicknesses of 1.0" (25 mm) to 4.0" 1102 mm). Thermal Performance Thlolinornlnom,) Viable (Conductance) In mm BTU /ihr"h' "•F) W /mr••C 1.0 26 .187 .05 1.2 30 .14 .70 _13 33 .12 .08 1,4 30 .11 .82 1.5 38 .10 .57 1.6 41 .09 .51 1,8 46 ,08 .45 2,0 51 .07 .40 2,3 58 .06 .34 2.5 54 .054 ,31 2,7 69 .05 .28 3.0 76 448 ,26 3,2 81 .043 .24 3,4 86 .04 .23 3.8 97 .036 .20 4.0 102 .033 .19 R•Voluo (Roslstsnce) (hr "h'"•FVBTU m'" C/W 8,0 1,05 7.1 1.25 8.3 1.47 9,1 1.50 10.0 1.78 11,1 1,08 12,5 2,20 14,3 2.52 15.7 2.94 18.0 3.27 20.0 3,52 22.0 3.83 23.4 4.10 25,0 4.40 28,0 4,89 30.0 5.34 The thermal values of E'NRO'Y 2 were determined in accordance with PIMA Technical 8ullgtin 101 and ASTM C 1209. Recent investigations have indicated that reduction In foam thermal performance will continue to occur after the PIMA six-month conditioning period. The ultimate R•volue of these products will depend on individual installation circumstances. When calculating the anticipated therms r e these products, JM suggests the use of a (0.90 m' •'C/WM. r t ellpected life of h bf loam thickness JUL 1 9 2002 Refer to the Material Safety f a and Product Label prior to using this-pred#tg •p ti tl; this data sheet ask for RSMygg � �' z� ✓U 1 Johns Manville S Description Retro•Fit Board is a high density board made of expanded perlite and cellulosic fibers, The top surface is sealed with topLoc• coating to ensure good attachment in bituminous applications, Retro•Fit Board meets the physical requirements of ASTM C 728. Use ''A" Rotro•Flt Board Is a perlite•based utility board for use as a divorcing layer in reroofing, and in new construction as a top layer In multl•layer Insulation systems, It serves as an upgrade for wood fiber utility rooflrig products, It may be applied with hot asphalt or mechanical fasteners. It Is not recommended for use directly over steel decks, W R Frd•Fit1oird hate'biifl ritad In numerous Factory Mutual fir end wind!reilstant systoms and is also approved for. use In specific Undirmnitbrs,Lsboratorles, Inc, Class A constructions. f. Advantages • Excellent strength and handloability • Good dimensional stability • Expanded porlito composition • Stable "R "•value • Minimum recycled content of 35% by weight ' /z' Retro -Fit® Board Typical Physical Properties Values Test Method Water Absorption, % by Volume - 2 hre 3.5 max. ASTM C 209 Compression Resistance 5% Consolidation -psi ,351241 kPo) ASTM C 165 10% Consolidation -psi 501345 kPo) Laminar Tensile Strength - psi „4.9133.8 kPo) ASTM C 209 Flexural Strength -psi 801414 kPa) ASTM C 203 Product Density-pof 11.14 1176.224 kg/m')..ASTM C 209 Linear Expansion 0,5% max, ASTM C 209/ ASTM D 1037 Thermal Performance Thickness (nom.) C•Value (Conductance) R.Value (Resistance) In mm • BTU/Ihr•tt'•'F) W/m'•'C (hr•ft'•°FNBTU m'•'C/W 13 0.78 4.3 1,32 0,23 Sites Rotro•Fit Board is available in 2' x 4' (0,81 m x 1.22 m), 4'x4'(1.22mx 1.22 m) or 4' x 8'11.22 m x 2.44 m) boards. CITY Of TUKINII.A APPROVED JUL 1 9 2002 M r: ( L Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS-5047, ..1 grid Johns Manville Prn(III( t!, • Description UltraFast Mechanical Fasteners for roof insulation are #12 diame- ter, hex washer hoed fasteners with a modified buttress thread form, "r-point tip and blue Climaseal. Premium Coating. UltraFast is manufactured from case hardened steel and coated with SPEX, a polymer coating, A second, metal filled, premium, polymer coating called Climaseal is then applied over the SPEX coating. UltraFast Locking Plastid Plates are blue, 3' (76 mm) round, high strength polyol6fin plates with a patented locking feature for use with UltraFast Fasteners, UltraFast Galvalum. Metal Plates are 3'176 mm) square, premium Oeivalume metal plates for Uso with UltraFast Fasteners. OlesFast Plastic Plates are rod, 3' (76 mm) octagonal, high strength polyolefin plates with a recess cavity for the fastener head, They are strictly for use with Johns Manville (JM) Fiber Gloss Roof Insulation, Use UltraFast Fasteners end Plates aro used to attach roof insulation to either motel (18.22 gouge 11.6 mm • 0.8 mmj), or wood docks, Tho screw and plate system provides positive attachment and roils• tondo to uplift forces, UltraFast Mechanical Fasteners for roof Insulation are the fasteners approved to install JM roof Insulation within any JM Roofing System Guarantee, either penal sum or NDL UltraFast® Fasteners and Plates Advantages • Hex washer hood improves driveebillty • Buttress thread design provides maximum pullout values and minimizes fastener pullout • Thread length permits attachment of insulation through high or low rib of roof deck • Patented "r-point provides unsurpossed drilling consistency • UltraFast exceeds the corrosion resistance standards of Factory Mutual Specification 04470 for Class IA Insulated Stool Dock Construction, including Windstorm Resistance 1.80 and 1.80 Classification, UltraFast Is also approved for use in Dade County, Florida, Application UltraFast Fasteners shell be installed through UltreFast Metal or Looking Plastic Plates at Factory Mutual usage rates and patterns appropriate for the site and typo of insulation, An ITW Bulldex Accudrive XL or a standard screwgun with a dis• engaging clutch should be used to install UltraFast Fastonors. The screwgun should have an RPM range of 1,800.2,600 only. UltraFast must penetrate the metal flange a minimum of %' (19 mm). UltraFast is fully seated when the head is tight against the metal plate, or snaps into the UltraFast Locking Plastic Plates. UltraFast should not be overdriven as to cause the plate surface to deflect more than %i (1.6 mm). Overdriven fasteners will significantly reduce fastener and plate performance and corrosion resistance and /or strip the deck. Cupped plates, caused by overdriving fasten- ers, will also damage the membrane, Underdriven fasteners will not distribute the load over the plate properly, For steel decks, Factory Mutual requires that the fastener pene- trates the deck at the top flange. Sizes Available in a wide range of screw lengths, ranging from 1W (41 mm) for insulation thicknesses of W to W (13 to 22 mm) up to 14" (386 mm) for thicknesses up to 101/,' to 13W (260 to 337 mm). UltraFast Oalvalume Metal Plates — 3' (78 mm) square. UltraFast Locking Plastic Plates for roof insulation — blue, 3' (76 mm) round, high strength polyolefin plastic. GlasFast Plastic Plates for fiber glass roof insulation are red, 3' (76 mm), octagonal, high strength polyolefin plastic. CITY OF TUKY 1LA APPROVED JUL 19 2002 As ri!iLD Refer to the Material Safety Data Sheet ag {° ttlalibl'p'i13F'-. to using this product. For an identical copy of this data sheet ask for RS-7099. .1. • • Roofing hsi.: alt ASTM D312.84 SPECIFICATIONS CRYSEN MANUFACTURING SPECIFICATIONS TYPE DESIGNATION SOFTENING POINT 135151 158.176 185.205 210.230 I DEAD LEVEL II FLAT III STEEP iV SPECIAL STEEP PENETRATION 77°F 18.60 18.40 15-35 12 -25 Modified Hot Stuff Plus Asphalt . -� —�- CRYS,EN MANUFACTURING SPECIFICATIONS TYPE' DESIGNATION SOFTENING POINT PENETRATION •F 7 PLUS 3 190-210 30.60 IV PLUS 4 210-225 30-50 Waterproofing Asphalt'"' ASTMD449 -83 SPECIFICATIONS CRYSEN MANUFACTURING SPECIFICATIONS TYPE II SOFTENING POINT( °F) 115-140 145.170 180-200 PENETRATION(77 °) 50-100 25.50, 20-40 DUCTILITY 771 (CM) MIN, 1a •3 2,5 1,5 DUCTILITY 39,2'/77' (CM) MIN, 35/75+ 30/75+ DUCTILITY 770(CM) MIN, 30 10 2 Crysen Refining makes every effort to produce the highest quality roofing an41 waterproofing as halt in the western United States, Since Crysen is a refiner /producer, they have the ability to insure quality from the crude barrel through the refining process to the finish of the oxidizing of the asphalt, and that's HOT STUFF, Crysen Refining 2355 South 1100 West Woods Cross, Utah 84087 (801)298 -3211 FAX (801)298.1112 CITY OF TUKWi1A APPROVED JUL 19 2002 AS NOi�.0 D4oiC �' tL , DIVt "NJt'l� • • ASTM0312 -78 sekatitng and Maturing 9.1 Asphalt shall be suitably packaged (i( not shipped in built) to permit acceptance by the carrier and to afford adequate protection from the normal hazards mdling and shipment. 9.2 Each container shalt be plainly marled with the name and brand of the manufacturer or seller and the type of product. 1 t'%►t ptgi.iren.+.tt at Asphalt is 11.611a/ Privets? Sol:enins pint. ('fl flub point.'C t'i1 PeeetrAwe. wink si et Orr) 1111•C1711) • et eb'C 11 t l'9') Dumbly it 2S4C (7VFy. ar Sao beet to (f a forth. 99 fine. % 1' 11 Taw sit Mu M+.+ Mai Hors 44 051) Ji 40 120 ... ..: 10 (MI r0 (176) 11:1(105). ::s (e)7) ., 211 (437) 6 it 3.d 99 d e0 13 100 • • .. 2,s Mesa •'rvve IV Mfo Mat 96 (20S) $9 (210) 107 (223) 4•• 21$017) ... • 90 i9. 1.. 6 12 tf 94 23 7; • . X7. SLOPC CUIDV.LINES X1.1 Thls appendix covers suggested slope guidelines for the lour type' or asphalts. Hower. no restrictions ate implied or intended on the dope et which a sppeecttic type of asphalt must be used. These guidelines ins,/ be modified to whatever degree u swilled by the familiarity end a nenee of those skilled in the art or buitt•up rooting eon. sarwtton and performance as well ai with total 1110611j 611%1C11116 and Ioal weather conditions. For eumpie, modifications trap the wiggliest guide. hnu may be nude depending upon: the type and occupancy of the buitdmg; tM nature or (ha roofing compoeanss and the toolsystun Construction, in. eluding type and thickness of Insulation; the appli• anon procedures. raeluding the uperi nos and ampelinty of the roofing rew; and the gooks specification. including sailing requtnntenu, Other considerations may include but ahomid not be IV striated so the cMmieai and rt►eologkai properties of the asphalt; the type a,ad character of the (alt or ((bnc wed; the amount tsl asphalt used between plies; the color type, and mass of sur(aein ; and Ow dkc 11on of exposure. Keeping In mind these consrderahons and that ma sanction are inleoded 011 the slope at which a specific asphalt mutt be used, the /showing =vtdelines are provided. X1.1 Type / includes asptuhs that ate telauvely susceptible to flow a root temperatures with gond adhesive and "self•ttealing" properties. They ate genitally used in slag. or gtavel.sur(aced roots on inclines up 10 4.17 9b (tla in. /II) slope. X1.2 Type 11 includes asphalts that ate model• sully susceptible to flow at tool temperatures. They are generally for use in buiit.up goof construction on inclines from appron.mateiy 4.17 'lb (oft in /ft) slope to 12.5 lb 1'Ii in. /11) slope X1.3 Type 111 includes arphalu that 114 ttetb ni►,ely nonursorptibls to flew at toot temperature; for 1w in the codstruetien of budi.up roof UMIAK. (1011 en inclines from apptoxlmately 63 4b (I Ind (l) slops to 35 96 (3 in (t) slope. XI A •t)'M N mclwlea asphalts that are genes• aly non,usceptibla to lbw at root tethpcmtutes for use in the amstrucion of buitt.up tooling on inn dines from approximately 16.7 % (1 inns) slope to 30 'St (6 mitt) slope. These asphala may be useful in vest; where relatively bosh ysanround temperatures are eipenenond. Tar 4.ww*4 $.!.rq I r rut Moorish Cosa is maim rerpr►wy sir rvNrr rey tr�rsr r�M, awns/ r► rkwtown .iO t f ..w a.i.r..rrf it Oa s«a.d u,rnr +i� 411 ww.1 ar yowl/ .o.► bwv.wu ier j/ rM refIf69. poi ;wow of Oa awd air I'is./ offule` esi r /of*new& r1 nervy into. own nnerodkik, fair non1arl lr triton r "salsa « wry nww ►t die evipmerr4 suntan I loismoute and tutus Ar oir4worl rwry ftvr Ma en,111 nor natal, rrA V ,rappOOpw14 w w,thpro•.n Yew' t.wwro n «►.nt tidy kr Nwiaa r /tau inifivl rte /e+ed1«wwi 00.6.1.1.4 dad Aeon/ it &id/wr0 w n3TM Nrwie►.rnn, You torwmina •dl Istriaradarstewidecaaa 11i .1 warner 01i4 mpg.. pale .r*.Kld maminor. *AIM pad .Mt. V$4 /hoe fVr tAae,wr ' l II Aew .w WV e fell swot pi should ~ay yaw •.iws avows cs one ASrM Ceanww w Parriust, Hid Rut lt,. PMa.It(psir, p.. item, ran tr eV6fr. firrbr 4eNaC IrrOlboef err t4r•Vtq, 'm t a11114ir494 Are. )'er awry .,subs r.'Ar AVM a «N • f Dolor# ►, • 211 1 0 rJ i •• u 0 N CITY Of TUKWI A APPROVE!) ' .JUL 19..2002 A;a tYuILU Virj Johns Manville Description FesCent Plus Cant Strip FesCant Plus Cant Strip is manufactured from JM Cant Hoard, a high density, laminated board made of high strength fibers and expanded parka, Fa§Cant Plus Cent Strips aro fabricated into many different cant sizes to moat the needs of the project. The base board that Fa§Cant Pius Cant Strip is manufactured from moots the material requirements of the !/" (13 mm) partite board in ASTM C 728, Tapered Fesca Edge Strip Tapered Fosco Edge Strip is manufactured from JM Fosco Board, which is composed of expanded porlite, a volcanic ore, and blend- ed with selected binders and fibers, Tapered Fosco Edge Strips are available in standard sizes to meet special needs. The base board that Tapered Fosco Edge Strip is manufactured from meets the material requirements of the W (19 mm) porlite board in ASTM C 728, use FesCent Plus Cent Strips provide an excellent way to transition from the deck to the well of the roof. Because of its high porlito content, FosCent Plus Cent Strip offers for greater fire moistener; then conventional wood fiber materials. This feature is important to all roofs, but ospociolly applicable to heat weldable modified bitu- mon systems and fleshing details. Tapered Felon Edge Strips are good for transitioning from mom- bran. to nailer or transitioning from a Tapered Fosco, Tapered E'NRG'Y 2 or Tapered Fesco Foam panel to the roof level to help promote positive drainage, Because of its porlite content, Tapered Fosco Edge Strips offer for greater fire resistance then conventional wood fiber materials, FesCant Plus Cant Strip Tapered Fesco Edge Strip Both FesCent Plus Cent Strips and Tapered Pasco Edge Strips comply with the Environmental Protection Agency Regulation 40 CFR Part 248, "Guideline for Federal Procurement of Building Insulation Products Containing Recovered Materials ", as a recy- cled product approved for use on any project using federal funds. FesCent Plus Cent Strips have at least 35% post-consumer racy= clod content, end Tapered Fosco Edge Strips have of least 25% post-consumer recycled content. Advantages • Excellent fire resistance • Dimensional stability • Strength and handleability • Meets RCRA requirements for recycled content rib tot Typical Physical Properties' Values FesCant Plus Cant Strip Values Tapered Faso Edge Strip Test Method Water Absorption, % by Volume - 2 hrs 3.5 max....................1.5 max, ASTM C 209 Compression Resistance 5% Consolidation-psi-,...„.,.35 (241 kPa ),,,,,,,,,,,,,,,,,,,,,,,,,,,,30 (207 kPa),,. ,..,,.,,,,,,,,,,,,,,,,,,,,.ASTM C 165 10% Consolidation-psi ,.,,,,.,.,.,50 (345 kPa) ,,, ,,,,,,,,,,,,,,,,,,,,,,,,,401276 kPa) Laminar Tensile Strength -psi .,,.4,9 (33,8 kPa) 7 (48 kPa) ASTM C 209 Flexural Strength -psi 60 (414 kPa ),,,,,,,,,,,,,,,,,,,,,,,,65 (448 kPa) ..,,,...,..,.,....,,.ASTM C 203 Product Density-pcf 11'14 (176.224 kg/m') 9 (144 kg/m') ASTM C 209 Linear Expansion 0,5% max 0.5% max, ASTM C 209 •Meewred on base board prior to febricetion of finished product Sites FesCent Plus Cant Strips are available in 3 ", 4', 5' and 5Ye (76, 102, 127 and 146 mm) sizes. Tapered Fosco Edge Strips are available in 6 ",12 ",18' and 24" (152, 305, 457 and 610 mm) lengths. CITY Of TIWWI A APPROVED JUL 19 2002 73174:7-t!-S7 Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS•5049. ‘i§ 4� Malarkey r TECHNICAL PRODUCT DATA SHEET #500 PREMIUM 1"` PLY SHEET ERCIMICLIIESMUZZIOS Product Uses #500 Premium 1 Ply Sheet M a high.strength ply sheet suitable for use. as an Interply in mult1•ply roof sya• terns. This high•*trength ply sheet may be used over various combustible and non•comhustihle decks as the initial ply or in conjunction with multiple ply roof systems. Please note precautions for limitations, Precautions: Do not mechanically attach ply *beet to any deck. A he sheet should he specified for mechanical attach. ment. Ply sheets are not recommended for cold process application, Malarkey ply *beets require dry storage and protec. tion from the weather, Do not apply wet ply sheets, Roof decks should be sound, dry. smooth. meet necessary local requirements and provide positive drainage, Composition and Materials: #500 Premium 1 Ply Sheet is manufactured with pure coating asphalt nn tested Malarkey fiberglass mat and treated with a nonstick agent to facilitate unrolling. No mineral release is used. A IIk+�11t1w Stlittaii�i�tlft Approval for itOn all fk.41t d toots, *See Malarkey manual for specified infonnetion. ISCIINCALUali Typical average properties, 5 square roll: Weight/roll Weight/square Dimensions Lay Lines Breaking Strength 48 lbs (21.77 kg) 9.6 lbs, (4,35 kg) 39)/0 wide x 165' long (1m wide x 50,3m long) 2 ", 9rh ", 121/" and 18)/4" minimum (50,8 mm, 238.1 mm. 317.5 mm. 476.2 mm) 44 lbs. (19.9 kg) *P /Inch minimum. both MD & XM Complies with ASTM D 2178.89, 'type IV and listed by PM and Wtl, Meets or exceeds the requirements of I IL 55 A Type 01 for asphalt content and minimum weight. Dade County Approval. #500 Premium 1 Ply Sheet shall be applied as specified In Maladinaurnaatangalsta= manual with a specified hue sheet and /or surfacing. It may bo applied In cold weather. Please follow cold weather application and general requirements. Nestslinsti Malarkey Roofing Company offers various warranties to moot specific requirements. The warranty package includes 5.. 10•,15• and 20•year limited and unlimited coverage. Contact Malarkey Roofing for full details, Tsu�uT _= RiyJCig Malarkey Roofing hu technical assistance available for all phases of built•up roof coverings and requirements, Inspectors axe available for consultations, job site, and final inspections, Contact your local representative and/or Malarkey office for details at 800/545.1191. &M AI= I= Malarkey #500 Premium 1 Ply Sheet is available throughout North America and Pacific Rim countries, Consult your nearest Malarkey source for additional information and availability. gftecarc 10.10.97. %uprnedes previously mbtishoddam. CITY OF TUKWIIA APPROVED JUL 1 9 2002 l%S U) R! {94`1{34vis+ 1ni97•MALAU4 Malarkey TECHNICAL PRODUCT DATA SHEET #502 PREMIUM "' FIBERGLASS MINERAL CAP SHEET Product Use: #502 Premium Fiberglass Mineral Cap Sheet is a fire -rated (FR) cap sheet manufactured to meet the needs of a conventional, quality built-up roofing system. 'Ibis cap sheet can he applied with hot mopping asphalt or cold process adhesives, Thls product is used as a surface sheet for multiple -ply roof systems, Precautions: #502 Premium Fiberglass Mineral Cap Sheet requires dry storage and protection from the weather, ill: not apply wet cap *heel Roof decks should be sound, dry, smooth, meet necessary local requirements and provide positive dralntige, Composition and Materiels: #502 Premium Fiberglass Mineral Cap Sheet is manufactured on tested Malarkey fiberglass mat. The glass mat is impregnated and coated with oxidized asphalt. filled with fire. retardant fillers and surfaced with ceramic granules for ultraviolet protection and weatherability. r�1 M tItiM`$$ijdMritia Approval for is on all fire-rated built-up roofs. #See Malarkey manual for specified Inform- lion, TACRIiQUJiAL Typical avenge properties, 1 square roll: Weight/roll Dim: pions Granule Adhesion Thickness 78lbs, (25,4 kg) 39r /s" wide x 33' long (lm wide x 10,0m long) 0.5 gram loss 90 mils Listed by UL. FM and Wilt Complies with UL 55A Type 03, UL 55D 23. Moots or exceeds ASTM D.3909.9I. Dude County Approval, Federal Spec SS R 630 D Clan 3. Ansicalinalociausi 1502 Premium Fiberglas Mineral Cap Sheet shall be applied as specified in the Mgt y e1_ manual with specified hue shoot and/or interply shoots. It may he applied in cold weather, Please follow cold weather upplication and general requirements, =Qi Malarkey Roofing Company offers various warranties to meet specific requirements. The we: runty pcwkdga Includes 5.. 10•,15• and 20.year limited and unlimited coverage, Contact Malarkey Roofing for full details, Tw11t11�.L R„_,aa Malarkey Roofing has technical auistanco available for MI phases of built -up roof coverings and requirements, Inspectors are avaUablo for consultations, job situ, and final inspections. Contact your local representative and/or Malarkey office for details at 800/545.1191, Malarkey #302 Premium Mineral Fiberglass Cap Shout is available throughout North America and the Pacific Rim coun• trios, Consult your nearest Malarkey source for additional information and availability, CITY OF TUKWILA APPROVED JUL 19 2002 AS t;J It.0 rG vi guflivs 10.10.97. Sspnss4cs piniowly pablik4 41 ti Malarkey TECHNICAL PRODUCT DATA SHEET #601 HIGH PERFORMANCE PREMIUM SBS CAP SHEET • WITH POL'YGLASS0MAT Product Use! 8601 High Performance Premium SBS Cap Sheet with Polyglass mat Li a f'iresrated (PR) mineral rap sheet manufactured to meet the needs of a high performance, quality built•up roofing system, This cap sheet ran he applied with hot mopping asphalt or cold process adhesives, This product is used as a surface sheet fur multipie•p1y front systems. Precautions: 8601 High Performance Premium 505 Cap Sheet with Polyglass mat requires dry !storage and pn►tectlon from the weather, Do not apply wet cap abut Roof decks should be sound, dry, smooth, meet necessary local requirements and provide positive drainage. Composition and Materials: 8601 High Performance Premium SBS Cap Sheet with Po!yglass mat is manufactured on Malarkey polyester /glass fiber (Polyglass mat with a random pattern of wet laid polyester fibers with resin and latex), lbe Polyglass mat is impregnated and coated with 50S modified asphalt filled with a fire retardant stabilizer and surfaced with ceramic granules for ultraviolet protection and weatherability. Applbillibilittliiiimites Approval for use on all Emitted built•up motto Please consult the Malarkey Menuat for specs• tied informations, nalltUCALDAZI Typical average properties, 4" aolvage. 1 square rt►tl: Weight/roll Dlmensk ns Granule Adhesion Thickness Breaking Strength B► 0411(.11°C) Breaking Strength ® 771 (251C) Elongation ' Break Ultimate Elongation @ Sample Break Thar Resistance 102 lbs. (46.3 kg) 39rh" wide x 34' long Om wide x 10.3m long) 0.5 gram Ion 120 mUa MD: 125 Iba,'PAn, MD: 80 Ibs, *P /in, MD: 4% MD: 23% MD: 98 Iba.•P /in, XM: 10011s.•P/ln. XM: 40 Ihs: }F /in, XM: 44 XM: 4091 XM: 90 ibr, +P /in. The above results per ASTM D 5147.91. Meets or snoods AVM D 3909.91. Listed by PM. tit, and Wit Dada County Approval, Federal Spec SS R 630 D Class 3, 0601 High Performance Premium SBS Cap Sheet with Polyglass mat `hall bo applied as specified in the Jdatazv Butl1.lus andaglxrdiiim manual with specified base sheet and interply sheets. It may be applied in moid weather, Please fallow cold weather application and general requirements, Mali ar Roofing Company offers various watrartdes to meet specific requirements. Warranty package includes 5=, 10•. 15. and 20•yoar limited and unlimited coverage. Contact Malarkey Rooting for full details, IganuCAL SIiI.YJCi6 Malarkey Rooting has technical assistance available for all phases of bulit•up roof coverings and requirements. Inspectors aro available for consultations, job•site and final inspections, Contact your local roprosantative and/or Malarkey office for details at 1.1100.545.1191. &M AIII1Ty Malarkey #601 High Performance Premium Polyglass SBS Cap Sheet is available thou fh out North America and Pacific Rim countries. Contact your nearest Malarkey source for more information and availability. TY ( Tij CC APPR0nD JUL 19 2002 1 t,ti D1,I±31011.1 Effective 10.1647. Svpoae6es ail pariovslypvglithe44 ;4. ✓1% 1 Johns Manville Description Bestile Industrial Roof Cement is a premium grade mastic designed for use In the construction of professional roof fleshings and details, It is a blend of selected asphalts, non-asbestos fibers, selected fillers and petroleum solvents, This is a high quality prod- uct, supplied in a smooth, easy-working consistency, which adheres to wet and dry surfaces, Bestile Industrial Roof Cement resists slumping yet remains plastic. Therefore, it may be used on both vertical and horizontal surfaces. It has a high resistance to weathering and provides excellent durability against the stresses and wear to which flashing adhesives are normally exposed, Use Bestile Industrial Roof Cement Is designed as a waterproof adhesive component of base fleshings, projection and penetration fleshings for commercial/industrial roofing systems. It is also en excellent sealant for countorflashings. It is used where dissimilar materials must be joined and sealed watertight. Bestile Industrial Roof Cement may be used as a flashing adhesive on both vertical and horizontal surfaces, It may be used for repairing bituminous roof surfaces and for waterproofing and flashing whore a heavy duty product is required, Because of Its ability to bond to damp and wet surfaces, it may be used for emergency repairs, It has the necessary body, eon• ',stoney end resiliency to maintain a strong, waterproof bond during varying temperature and weather conditions, Caution Combustible, Bestile Industrial Roof Cement contains petroleum distillate, To minimize risks: KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAME • AVOID PROLONGED CONTACT WITH SKIN • AVOID PROLONGED OR REPEATED BREATHING OF VAPOR • AVOID CONTACT WITH EYES • DO NOT TAKE INTERNALLY • USE WiTH ADEQUATE VENTILATION • KEEP CONTAINER CLOSED WHEN NOT IN USE • KEEP OUT OF REACH OF CHILDREN. Typical Physical Properties Material meets the requirements of ASTM D 45118, Type I, Color Black Solids Content 75.78% by Weight Weight per Gallon 10,0.10,2 lbs (1,20 1.22 kg /liter) Drying Time (70 °F (21 °C), 50 %RN) 6 Hours Shelf LUfe Indefinite in Airtight Container Coverage (W 13 mm) thickness) 14 sq, ft. per gallon (0.34 m' /liter) f'rnrlii( t', • BestiletM Industrial Roof Cement Application All surfaces must be clean and free of oil, grease, rust, scale, loose paint, dirt and debris, Porous surfaces require priming with JM Concrete Primer, Primer must be allowed to dry prior to the applica- tion of Bestile Industrial Roof Cement. Bestile Industrial Roof Cement Is applied with a trowel, in a thickness of W (3 mm), Do not apply in thickness exceeding W18 mm), Apply cement liberally in joint areas, seams or cracks, Work the cement to a feather edge to provide a smooth transition and facilitate drainage. The cement should bo reinforced with roofing felt, base flashing shoots or gloss fabric. For bolt results in cold weather, store unopened containers in a warm oroo for at least 24 hours prior to application. Equipment and tools can bo cleaned with kerosene or mineral spirits immodi• atoly after use. Use extreme core when handling solvents, Coverage Bostila Industrial Roof Cement should be troweled onto the sur• face to which flashings are to bo adhered In approximately W (3 mm) thick layer. Do not apply thicker than W (0 mm). One gallon of material will cover approximately 14 square foot (0.34 m' /liter). Packaging 5 gallon (18.9 liter) pails. CRY OF TUKWILA APPROVED JUL. 1 9 2002 Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS-2029. tird Johns Manville Description Concrete Primer is a thin brushing, cutback asphalt primer, Use Concrete Primer is used to prime concrete roof decks, brick and other masonry used in parapets and walls to which fleshings ere to be applied. It prepares these surfaces to receive hot asphalt or cold asphaltic cements and ensures good adhesion. Concrete Primer also makes an excellent primer for metal edge strips and other metal roof components which are to receive asphaltic coatings or cements. To minimize risk: AVOID PROLONGED OR REPEATED BREATHING OF VAPOR • AVOID CONTACT WITH EYES • DO NOT TAKE INTER. NALLY • USE WITH ADEQUATE VENTILATION • KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAME • KEEP CONTAINER CLOSED WHEN NOT IN USE • KEEP OUT OF REACH OF CHILDREN Application Apply Concrete Primer by brush, roller, or spray to surfaces which have boon cleaned of dirt and loose material. Allow to dry thoroughly before proceeding with tho application of the roofing system, Pr ()dm t', r Concrete Primer Concrete Primer can be used at any time of the year. In weather below 40'F (4'C), koop in a warm area (70'F (21•C)) until reedy to use, to make application easier, The Primer is reedy for use right out of the container end should not be diluted. Material meets the requirements of ASTM 0 41. Coverage Ono gallon (3.8 (hors) coven approximately 100 square foot (0.28 m') of roof area, Packaging 5 gallon (18.8 liter) polls and 55 gallon (2082 liter) drums. CITY Of TUKWILA APPROVED JUL 19 2002 AS riiau DIV sStoi►i Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS -2065, "SINCE 1919" July 16, 2002 HAIGHT ROOFING COMPANY, INC. Mailing Address: P.O. Box 70150, Seattle, WA 98107 Area Code: (206) 784 -8414 INDUSTRIAL • COMMERCIAL - ROOFING and SHEET METAL WORK Fax: (206) 784 -1058 INSULATING CONCRETE ROOFS DECKS REROOFING SPECIALISTS City of Tukwila Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Commercial Reroof 1161 -1177 Andover Park West, Bldg. "13" 1141 -1159 Andover Park West, Bldg, "C" RECEIVED CiTY OF TUKWILA JUL 17 2002 PERMIT CENTE:Ei The existing roof system on the above referenced commercial building consists of a fiberglass base sheet attached to the structural roof decking (plywood), followed by three layers of fiberglass ply sheets set in roofing asphalt, The ply sheets were then glazed with an additional mopping of roofing asphalt, Others have added minor and insignificant additional materials at random area in the effort to repair apparent roof leak problems, The new roof system will be applied following tear off and removal of the existing roof membrane components down to the top surface of the existing structural plywood roof deck and will consist of R -9 polyisocyanurate insulation covered with a one -half inch perlite cover- board, mecli nically attached with screws and plates, followed by three layers of fiberglass ply sheets set in roofing asphalt, The roof will be finished using mineral surface fiberglass capshcet set in roofing asphalt, Base flashings will consist of two ply's of roofing felt set in roofing asphalt covered with a mineral surface capsheet set in roofing asphalt, Malarkey Roofing Company in Portland, Oregon manufactures the new roof system materials, The manufacturer's roof system specification is M4 -WU- BHA -H, Sincerely, Haight Roofing Company, inc„ Chuck Mahlum Project Manager y`'tit ihea4re4 Vl (t0101° CITY 0 1 l AA_ 19 2002 f p:!Ii:O flt NZ -SK MIOIOI Members: Western States Roofing Contractors Association / National Roofing Contractors Association Washington State Contractors Registration Number HA- IG- HR- C269QK PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: . .MI02 -108 • PROJECT NAME: Southcenter West Bus Park SITE ADDRESS: 1.177.._AndOver_PkW — Bldg B. DATE: . 0.7 -17 -02 ,,,,.Original Plan Submittal ,...Response to Incomplete Letter # _-_--- Response to Correction Letter # Revision # After Permit Is Issued A PARTMEN 40 7-# -6 Build n g uivision Public Works ❑ Fire f5rev nton Structural ❑ Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE :..07 4O i 2. Not Applicable El Permit Center Uro Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined Incomplete: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CC RE.C,TIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: MAED,L Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED; Departments issued corrections; Bldg ❑ Fire ❑ Ping (J PW ❑ Staff Initials: Pocumenlshouting slip.doc 2.28 -0Z ti DEPARTMENT OF LAI3OR AND INDUS'T'RIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ...a:EXP DATE 0001 i1AIGHRC269QK'05/02/2004 EFFECTIVE'DATE - 11/12/1974 HAIGHT ROOFING COMPANY INC PO BOX 70150 SEATTLE WA 98107 Stole of Wa htnston DEPARTMENT OF LABOR & INDUSTRIES PO BOX 44450 OLYMPIA WA 98504 -4450 HAIGHT ROOFING COMPANY INC PO BOX 70150 SEATTLE WA 98107 DLY P DF) WA. e4.."..t.c.- ;Ix - P - i 1W �i lir i !W rl ti li:. 1 tW4iJ4 I TC PIit3'P CLASS MAIL. US POSTAGE i � 1 PERMIT NO 312 :3