Loading...
HomeMy WebLinkAboutPermit MI02-109 - SOUTHCENTER WEST BUSINESS PARK - REROOFSOUTHCENTER WEST BUSINESS PARK 1141 ANDOVER PK W EXPIRED 01 -20 -03 M102 -109 City of 'Iukwi1a Department of Community Development / 8300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049098 Address: 1141 ANDOVER PK W TUKW Suite No: MISCELLANEOUS PERMIT Permit Number: Issue Date: Permit Expires On: Tenants Name: SOUTHCENTER WEST BUSINESS PARK Address: 1141 ANDOVER PK W, BUILDING C Owners Name: CALWEST INDUSTRIAL PROP Address: C/O DELOITTE & TOUCHE LLP, 2235 FARADAY AVE 110 Contact Persons Name: RON HAIGHT Address: 4910 15 AV NW, SEATTLE, WA Contractors Name: HAIGHT ROOFING COMPANY INC. Address: P.O. BOX 70150, SEATTLE, WA Contractor License No: HAIGHRC269QK DESCRIPTION OF WORK: TEAR OFF EXISTING ROOF AND REPLACE WITH NEW ROOFING MEMBRANCE ONLY. M102 -109 07/23/2002 01/19/2003 Phone: Phone: 206484.8414 Phone: 206 784.8414 Expiration Date: 05/01/2004 Value of Construction: Type of Fire Protection: Type of Construction: $181,113.70 Fees Collected: $2,401.87 Uniform Building Code Edition: 1997 Occupancy per UBC: 0025 Public Works Activities: Curb Cut/Access/Sidewalk/CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: N Land Altering: N Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: Channelization / Striping: Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Private: * Continued Next Page ** Public: M102.109 Printed: 07.23 -2002 City of Tukwila Department of Community Development / 6300 Southcenter 8L, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: Date: This permit shall become null and void if the work Is not commenced within 180 days from the date of issuance, or If the work is suspended or abandoned for a period of 180 days from the last inspection. ig doe: Miscperm M102-109 Printed: 07 -23 -2002 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 3523049098 Address: 1141 ANDOVER PK W TUKW Suite No: Tenant: SOUTHCENTER WEST BUSINESS PARK Permit Number: MI02.109 Status: ISSUED Applied Date: 07/16/2002 Issue Date: 07/23/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The Issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. i hereby certify that I have read these conditions and will comply with thorn as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date :,___ 5 . p -I doc: Conditions MI02.109 Printed: 07-23-2002 C /TY OF T '� �'KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name/Tenant: Southcenter West Business Park Description of work to be done (please be specific): Tear -Off existing roof and replace with new roofing membrane only. Value of Construction: $ 181,113.70 Site Address : City State/Zip: 1141 -1159 Andover Park West Bldg 'C Tukwila, Wa 98188 Tax Parcel Number: Property Owner: Cal West Holdings LLC C/O Equity Office Phone: ( ) -r 425- 467 -1640 Street Address: City State/Zip: 500 - 108th Ave. N.E. , Suite #240, Bellevue, WA 98004 Fax #: (425 ) Contractor: Haight Roofing Company, Inc. City State/Zip: Washington 98107 Phone: ( ) 206 - 784 -8414 Fax #: ( ) 206- 784 -1058 Street Address: 4910 - 15th Avenue N.W. Seattle * X: $K *X ( Consultant D 7 Consulting, Inc. Phone: (949- 9 949-955-2777 Street Address: City State/Zip: 4101 Weser erly Place, Suite 110, Newport Beach, CA 92660 Fax #: ( ) 949 - 955 -2829 Engineer: N/A Phone: ( ) Street Address: City State/Zip: Fax #: ( Contact Person: Ron Haight 0 Standby Phone: ( ) 206 - 784 -8414 Street Address: 4910 - 15th Avenue N.W. Seattle City State/Zip: Wash'nstsn 9:10 Fax #: ( ) 206 - 784 -1058 MISCELLANEOUS PERMIT'REVIEW AND APPROVAL RE • UESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): Tear -Off existing roof and replace with new roofing membrane only. Will there be storage of flammable/combustible hazardous material in the building? ❑ yes ® no Attttachh list /materials and story o location on se ar�nt_1 /2 X 11 pa ar indenter r uantltles & MateriaLL.dety Data Sheets Above Ground Tanks Antennas/Satellite Dishes Bulkhead/Docks U Commercial Reroof ❑ Demolition ❑ Fence ❑ Manufactured Housin flecplacement only ❑ Parking Lots ❑ Retainin Walls ❑ Tem fora Facilities al Tree Cuttin APPLICANT RE • UEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS Channellzntion/S1riping ❑ Flood Control Zone ❑ landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt N ❑ Water Meter /Permanent N.,�_ ❑ Water Meter Temp N ❑ Miscellaneous Curb cut/Accoss/Sidowalk ■ Fire Loop/Hydrant (mein to vault)#: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 _sq. (t,grading/clearing ❑ Sanitary Side Sewer N: ___ ❑ Sewer Main Extension 0 Privato 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal tii loving Oversized Load/Hauling Schedule: MONTHLY SERVICE BILLINGS TO: Name: ....� Phone: Address: City /Sta e/ZIp: .� 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT/REFUND BILLING: Name: Phone: Address: City /State/Zip: Value of Construction • In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review • Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 'NG - 2. 9/9/19 nniscpna.doc Date application expires: /-14-03 Application taken by: (initials) Alt .%41SCTIIAN'TOUS Pt' T APPLICATIONS MUST BT SUBMIT ,s''"•4 WITH lift FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED Y ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H4, "Affidavit in Lieu of Contractor Registration ". Maki* Owner /Authorked ARrnt If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permaappllcatlon and obtain the permit will be required as part of this submittal. i r I NERDY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY RV THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 1 .. .ter. O L. . R ' H//OA I , AGENT) til ;R\tII - NIT! I \IION AND RI (1L IRE 1) ( III( kl I'I IOft I'FR■11I RFVIFVV Submit checklist No: M -9 Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 ❑ Antennas/Satellite Dishes Submit checklist No: M -1 ❑ Bulkhead/Dock Submit checklist No: M =10 ® Commercial Reroof Submit checklist No: M -6 ❑ Demolition Submit checklist No: M -3 © Fences • Over 6 feet in Height Submit checklist No M -9 ❑ Land Altering/Grading/Preloads Submit checklist No: M -2 Miscellaneous Public Works Permits Submit checklist No: 1-1.9 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M.5 ❑ Moving Oversized Load/Hauling Submit checklist No: M.5 ❑ Parking Lots Submit checklist No: M.4 ❑ Retaining Walk - Over 4 feet in height Submit checklist No: M -1 Temporary Facilities Submit checklist No: M.7 ❑ Tree Cutting Submit checklist No: M.2 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H4, "Affidavit in Lieu of Contractor Registration ". Maki* Owner /Authorked ARrnt If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permaappllcatlon and obtain the permit will be required as part of this submittal. i r I NERDY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY RV THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 1 .. .ter. O L. . R ' H//OA I , AGENT) SISnalure: 0fl - Date: 7/16/02 Print name: Chuck Mahl um `�� Phone: ( 2Q617g4_g414 - Fax #: (206 -1184 -1058 Address: p.Q� Box 70150 itY /State/Zip :6ua diet Washing on 98107 " 919199 Mlscpotduc City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 3523049098 Permit Number: MI02 -109 Address: 1141 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 07/16/2002 Applicant: SOUTHCENTER WEST BUSINESS PARK Issue Date: Receipt No.: R020000988 Payment Amount: 944.42 Initials: KAS Payment Date: 07/17/2002 09 :17 AM User ID: 1684 Balance: $1,457.45 Payee: HAIGHT ROOFING CO TRANSACTION LIST: Amount Type Method Description Payment Check 21942 944.42 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 944.42 Total: 944.42 . 3t :k; )7/10 1716 TOTA,l 18130 .114 doc; Receipt Printed: 07- 17.2002 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049098 Address: 1141 ANDOVER PK W TUKW Suite No: Applicant: SOUTHCENTER WEST BUSINESS PARK RECEIPT Permit Number: MI02 -109 Status: APPROVED Applied Date: 07/16/2002 Issue Date: Receipt No.: 8020001024 Initials: SKS User ID: 1165 Payment Amount: Payment Date: Balance: 1,457.45 07/23/2002 10 :31 AM $0.00 Payee: HAIGHT ROOFING COMPANY TRANSACTION LIST: Amount Typo Method Description Payment Check 21948 ACCOUNT ITEM LIST: Current Pmto 1,457.45 Description Account Code BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 1,452.95 4.50 Total: 1,457.45 44 57/25 1716 TOTAL 2914.90 Printed: 07 -23 -2002 1§ 1 .r:• INSPtCTI ©N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, $100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (206)431 -3670 Protect: y •- ;rxa rr�/ '_7it ` tr-� °� rw 't 4 Address: di�I /,0au �Ae Type of Ins tion: .c - .4"&i. Data ca ad: -23-oz Special Instructions: Date wa > 00, e .m, Requas ,./ ` fG, ' � Phone: 'e'6 gal -,/,DY Approved per applicable codes. Corrections required prior to approval. COMMENTSt Date:.�,��t } $47.00 REINSPECTION WE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reins . ection. r •�;... Receipt No Date: D7CONSUL 4101 Westerly Place, #110 Newport Beach, CA 92660 EMENT SEATTLE, WASHINGTON 1141 -1159 ANDOVER PARK W 2002 ROOF REPLACEMENT - BUILDING C SOUTHCENTER WEST BUSINESS PARK KENT, WASHINGTON NAME: 0111PY03 DM 04002 DRW'N BY MBI 4 PANSY M4- CONVENTIONAL M4•XHA do s 4.5 i lime tateriatt per: fb ►fit snan ea a*.ino . tr °m ipping iI Wiel t i eft". Deck Type- Uninsulated Rating Slope in 12" BASE SHEET ATTACHMENT Depending on Deck Type Change Spec Number to Read' See Gen. Req. Mech. Fast. Asphalt Combust. /Nallable Wood N/A M4 -WI -XHA -H Hot Asphalt Structural Concrete N/A Structural Concrete A 2" C.7 Lightweight Concrete X M4- CU -XHA•H Lightweight Concrete N/A M4 -LI -XHA -H Metal A 2" N/A Metal N/A Structural Wood Fiber A 2" F.8 N/A Structural Wood Fiber N/A A 2" F.6 Hot Asphalt N/A Gypsum N/A 2" • I es. aua tv F.4; F.7 contro .. ec cons • erat Hot Asphalt on. an . 0 er genera M4 -PI -XHA -H toe cs. AnfDMtrn N/A Precast Slabs N/A N/A Deck -type- Insulated Rating Slope In 12" Insulation Attachment See Gon. Req. Roofing Attachment to Insulation Depending on Deck Type Change Spec Number to Read` Combust./Nailabie Wood A 2" F.2 M4 -WI -XHA -H Hot Asphalt Structural Concrete A 2" F.4 Hot Asphalt M4 -CI -XHA -H Lightweight Concrete A 2" F.5 Hot Asphalt M4 -LI -XHA -H Metal A 2" F.3 Hot Asphalt M4 -MI -XHA -H Structural Wood Fiber A 2" F.8 Hot Asphalt M4 -SI -XHA -H Gypsum A 2" F.6 Hot Asphalt M4 -GI -XHA -H Precast Slabs - a ar n a nr e mere - gnu rements! A - moons 2" • I es. aua tv F.4; F.7 contro .. ec cons • erat Hot Asphalt on. an . 0 er genera M4 -PI -XHA -H toe cs. AnfDMtrn Refer to Tab 11 for Products and Associated Materials information. Refer to Tab 6 for Execution Specifications. Refer to Tab 7 for Flashing Details. • Change last Character (H =.Hot Asphalt): JUL 1 9 2002 S=SEBS Hot Asphalt The same material must be used to attach the membrane to insulation.i .;i WILD 81.11 WING 671VT E 11/93•MAUSW ✓U 1 Johns Manville Pr ()(III( i� Description E'NRG'Y 2 is a rigid roof insulation board composed of a closed cell polyisocyanurate foam core bonded in the foaming process to uni- versal fiber glass reinforced facors. E'NRO'Y 2 meets the physical property requirements of ASTM C 1289 and Federal Specification HH =1.1972/Gon and HH =1.1972/2. E'NRO'Y 2 specialty products aro also available as tapered panels, pro•cut miters and pre =cut crickets, Use E'NRO'Y 2 provides high thermal insulation value over motel, nail• able, and non.nailablo roof decks in buiit•up, modified bitumen and single ply membrano roofing systems. It may be applied using hot bitumen, cold adhosivos or mechanical fasteners, The unlvorsal facor on the top and bottom side provide a suitable surface for mochanical attachment to structural dock as well as a suitable surface to apply hot asphalt or cold adhosivos, E'NRO'Y 2 has boon rated in Factory Mutual 1A•00 and lA•90 tiro and wind• resistant systoms for BUR, modified bitumen and singlo ply systoms In specific constructions. it has been classified by Undorwriterr Laboratories, Inc. as an approved roof insulation in many Class k roof constructions and Roof /Ceiling hourly firo•rated assemblies, and is classified by Underwriters Laboratories Canada, .. E'NRG'Y 2tM JM also supports NRCA Bulletin 19 in recommending that a cover board of Fosco Board, Fiber Glass Roof Insulation or W Retro•Fit Board be installed over foam insulations in hot mombrano systoms, Advantages • High thormal officioncy • Unlvorsal facer that is compatiblo with BUR, modified bitumen and singlo ply mombrano systoms • Complies with EPA roquiromonts • Moots Clean Air Act Amendments of 1900 Typical Physical Properties Values Test Method Wator Absorption, % by 1.0 max ASTM C 209 Volume - 2 hrs. Dimensional Stability Change: 7 days ®158 °F (10'C), 90.100% RH Lengthwise e2% ASTM 0 2126 Crosswise <2% Compression Resistance' 10% Consolidetion•psi (kPa) 20 (138) nom ASTM 01621 Moisture Vapor Transmission ** ,,,,,,,,,,,,,,,,,,,,,,,, <1 perm ASTM E 06 (57.5 ng /(Pa•s•m') Flame Sproadf* 25 max ASTM E 84 Service Tomperature •100 to 200 °F (•73° to 03 °C) •Alw salable in :spoil?? kPel. ••f°°i ca° onhr. For Use Over Metal Decks The minimum thicknesses of E'NRG'Y 2 insulation over metal decks are as follows; Width of Rib Opening Thickness of insulation (Minimum) Up to 2 %" (67 mm) Up to 3%" (86 mm) Up to 4 %" (111 mm) 1,0' (25 mm) 1.2" (30 mm) 1.3" (33 mm) Size: E' NRO' Y2is available in4' x4'(1.22mx1.22m)or4'xi3'(1.22mx 2.44 m) boards (other sizes available by special request) and in thicknesses of 1.0" (25 mm) to 4.0" (102 mm), Thermal Performance Thickness (nom,) C•Volue (Conductance) Ift mm BTU/Ih•h'01) W /m',•C R•Valuo (Resistance) (hrh "FI/BTU m'oC/W 1.0 1.2 1.3 1,4 1.5 1.0 1.8 2.0 2.3 2,5 2,7 3.0 3.2 3,4 3.8 4.0 25 ,107 30 .14 33 .12 30 .11 .10 .09 ,08 38 41 40 51 58 04 88 75 81 80 97 102 .07 .00 ,054 .05 .040 .043 .04 .030 .033 .95 .78 .08 .52 .57 ,51 .45 .40 .34 .31 .28 .20 .24 .23 .20 .19 8.0 7.1 8,3 9,1 10.0 11.1 12.5 14,3 10.7 18.0 20.0 22.0 23.4 25.0 28.0 30,0 1.05 1.20 1.47 1.00 1,78 1.90 2.20 2.52 2.94 3.27 3.52 3,83 4.10 4.40 4.89 5,34 The therms) values of E'NRO'Y 2 were determined in accordance with PIMA Technical Bullpen 101 and ASTM C 1299. Recent investigations have indicated that reduction In foam thermal performance will continue to occur after the PIMA six•month conditioning period. The ultimate R•value of these products will depend on individual installation circumstances. When calculating the anticipated thermal performance over the expected life of these products, JM suggests the use of an R•value of 5.56 per trill It fly ityn�K.A (0.98 m* • •C/W). I ` APPROVED JUL 1 9 2002 Refer to the Material Safety Data Sheet and todxchl el prior to using this product. For an identical ariy data sheet ask for RS-5039. Bt7•LDMG DtVr!11tg --- lg t Pr ()rim 1,, Johns Manville Description %' Rotro =Fit Board is a high density board made of expanded perlito and cellulosic fibers. The top surface is sealed with TopLoc• coating to ensure good attachment in bituminous applications, h' Rotro•Fit Board meets the physical requirements of ASTM C 729. Use Retro•Fit Board is a perlite•basod utility board for use as a divorcing layer in reroofing, and In new construction as a top layer in multi•layer insulation systems. It serves as an upgrade for wood fiber utility rooflfig products, It may be applied with hot asphalt or mechanical fasteners, It is not recommended for use directly over steel decks. WRRetr6'F1t Board his been' rated to numerous Factory Mutual fire and wInd'nsistant systems and is also approved for use In speclftb Underwriters Laborstorteei Inc: Close A constructions, P Advantages • Excellent strongth and hondloabllity • Good dimensional stability • Expended porlito composition • Stoblo "R"•votuo • Minimum rooyclod content of 35% by weight 1/2" Retro•Fit® Board Typical Physical Properties Values Test Method Water Absorption, % by Volume - 2 hrs 3.5 max. ASTM C 209 Compression Resistance 5% Consolidation -psi 35 (241 kPe) ASTM C 165 10% Conoolidation -psi 601345 kPa) Laminar Tensile Strength- psi4.9 (33.8 kPe) ASTM C 209 Flexural Strength -psi 60 (414 kPe) ASTM C 203 Product Density-pof 11.14 (176.224 kg/m')..ASTM C 208 Linear Expansion 0.5% max. ASTM C 209/ ASTM D 1037 Thermal Performance Thickness (nom.) C•Value (Conductance) R•Value (Resistance) in mm BTU /Ihr•ft1 "F) W /m'••C Wife •'F)/BTU m'oCIW 13 0.76 4.3 1.32 0,23 Si'.' h' Retro•Fit Board is available in 2' x 4' (0.61 m x 1.22 m), 4' x4'( 1, 22mx1. 22mlor4'x8'(1.22mx2.44m)boards. CITY Of TUKW$l.A APPROVED JUL 19 2002 >: 1t1) BUtLDT"NG f iV1Stt3t - Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS-5047. El/ Johns Manville Description UltraFast Mechanical Fasteners for roof insulation aro #12 diamo- tor, hex washer hoed fastoners with a modified buttress thread form, "X"-point tip and blue Climaseal• Premium Coating, UltraFast is manufactured from caso hardened stool and coated with SPEX, a polymer coating, A second, metal filled, premium, polymer coating called Climasoal is than applied over the SPEX coating, UltraFast Looking Plastic Plates aro blue, 3" (70 mm) round, high strongth polyol6fin plates with a patented locking feature for use with Ultra Fast Fasteners. UltraFast Oa'valume Metal Plates aro 3" (78 mm) square, premium Oaivalume metal plates for use with UltraFast Fasteners, OlasFast Plastic Plates are rod, 3' (78 mm) octagonal, high strength polyolofin plates with a recess cavity for the fastener hoed, They are strictly for use with Johns Manville (JM) Fiber Glass Roof insulation, Use UltraFast Fasteners and Plates are used to attach roof insulation to either motel (10.22 gouge (l,6 mm • 0,8 mm)), or wood docks, Tho screw and plate system provides positive attachment and roils• tondo to up•Iift forces, UltraFast Mechanical Fasteners for roof Insulation ere the fasteners approved to Install JM roof Insulation within any JM Roofing System Guarantee, either penal sum or NDL. Prnd j( 1c, UltraFast® Fasteners and Plates Advantages • Hex washer hood improves driveobility • Buttress thread design provides maximum pullout valuos and minimizes fastener pullout • Thread length permits attachment of insulation through high or low rib of roof dock • Patented "X "•point provides unsurpassed drilling consistency • UltraFast exceeds the corrosion resistance standards of Factory Mutual Specification /4470 for Class to Insulated Stool Dock Construction, including Windstorm Resistance 1.60 and l•90 Classification, UltraFast Is also opprovod for use in Dada County, Florida, Application UltraFast Fasteners shall be installed through UltreFast Metal or Locking Plaotio Plato. at Factory Mutual usage rates and patterns appropriate for the olio and typo of insulation, An 11W Buildax Accudrive XL or a standard scrowgun with a di.. engaging clutch should be used to install UltraFast Fasteners, The ecrewgun should have an RPM range of 1,800 2,500 only, UltraFast must penetrate the metal flange a minimum of W (19 mm), UltraFast is fully seated when the head is tight against the metal plate, or snaps into the UltraFast Locking Plastic Plates, UltraFast should not be overdriven as to cause the plate surface to deflect more than W11.6 mm), Overdriven fasteners will significantly reduce fastener and plate performance and corrosion resistance and/or strip the deck. Cupped plates, caused by overdriving fasten- era, will also damage the membrane. Underdriven fasteners will not distribute the load over the plate properly. For steel decks, Factory Mutual requires that the fastener pene- trates the deck at the top flange. Sizes Available in a wide range of screw lengths, ranging from 1W (41 mm) for insulation thicknesses of W to W (13 to 22 mm) up to 14" (356 mm) for thicknesses up to 10 %" to 13W (260 to 337 mm). UltraFast Oalvalume Metal Plates — 3' (76 mm) square. UltraFast Locking Plastic Plates for roof insulation — blue, 3' (76 mm) round, high strength polyolefin plastic, OlasFast Plastic Plates for fiber glass roof insulation are red, 3' (70 mm), octagonal, high strength polylTYhn plastic. �1 C APPROVED JUL 19 2002 AS k3(LU Refer to the Material Safety Data S101effiirid ?PtOt(dt'LBNCprtor to using this product. For an identical copy of this data sheet ask for RS-7099. ea • eft • • Roofing 'Asphalt ASTM D312.84 SPECIFICATIONS CRYSEN MANUFACTURING SPECIFICATIONS TYPE DESIGNATION SOFTENING POINT DEAD LEVEL 135.151 II FLAT 158.176 , III STEEP 185.205 IV SPECIAL STEEP 210.230 PENETRATION 77 °F 18.60 18.40 15.35 12.25 Modified Hot Stuff Plus Asphalt ----- CRYSEN MANUFACTURING SPECIFICATIONS TYPE DESIGNATION SOFTENING POINT 'F PLUS 3 190.210 IV PLUS 4 210.225 Waterproofing Asphalt~'"-- AST■D449 -83 SPECIFICATIONS CRYSEN MANUFACTURING SPECIFICATIONS TYPE SOFTENING POINT( °F) 115.140 II 145.170 180.200 PENETRATION 77°F 30.50 30.50 PENETRATION(77 °) 50.100 26.50, 20.40 • DUCTILITY 77° (CM) MIN. 10 .3 2.5 1.5 DUCTILITY 39,2 4777° (CM) MIN. 35/75+ 30/75+ DUCTILITY 77 °(CM) MIN, 30 10 2 Crysen Refining makes every effort to produce the highest quality roofing and waterproofing asphalt in the western United States, Since Crysen is a refiner /producer, they have the ability to insure the quality from the crude barrel through the refining process to the finish of the oxidizing of the asphalt, and that's HOT STUFF. Crysen Refining 2355 South 1100 West Woods Cross, Utah 84087 (801)298 -3211 FAX (801)298.1112 CITY OF TUKWILA APPROVED J1! L 19 2002 IBS, I )Ik.0 s e%. a.• •, • J• •11 • ASTM0312 -7h3 teloging and Marking 9.1 Asphalt shall be suitably packaged (if not shipped in bulk) to permit acceptance by the cattier and to afford adequate protection prepeNy So/sagas rosin. 'C 111 Flesh potet.'C ('fl Penerratroe. swot at 0'C (12'#) u 2S•C (71'F 1. • at 4100 Cliff) NAM, it 2S'C an solobdiy to (ticAbraretl• 'Saw. 0, from the normal hazards tndling and shipment. 9? Each container shall be plainly marled with the name and broad of the manufacturer or seller and the type of product. P . tibr J1p.Ltr..eW of Aonolt to booty Type 1 Tlgt 11 MI. IAeu Min Maa Mw 51(133) 44031) MOSS) &01116) 1:(165), 273 (ef7) ... :2S OM •.• .. 2.2i 0371 3 6 ■ 6 11 60 11 t0 11 St l!0 !00 Id4 ... 3A .., X2.5 99 99 .•, IN Type tit • Type iv Mu Mid Mu 6 (205) $9(210) 107 (223) ... 22S(411) .., SO 1 6 12 If 99 1S 71 • • •1' XS. SLOP/ Cl/ID /LINES X1.1 This append'li covert suggested slope guidelines for the lour types of asphalts. Howsisr. no restrictions are implied or intended on the slope at whkh a tpecs& type of asphalt must be wed. Thew guidelines may be modified to whatever degree u justified by tM familiarity and tic ranee o/ thole skilled in the an of builr•up roofing con. a1W43l0l1 and pet(ormanee as well as with tacit roofing practices and local weather conditions. For eaamp$I, modifications tray the wggested guide. hnts may be nude depunhhns upon; the type and occupancy of the buDdmg; the stature of the roofing and the tool system consrruation, tn• eluding type and thk$.nei of insulation; the appli. 4atton proeedutes, wallah/is the eapertence and competency of the roofing rew; and the roofing specification, including sailing requiremenu. Other considerations nay keeled/ but should not be re• sttkted to the chemical sad theological properties of the asphalt; the gyp( sal ebstaetet of the felt or (erne wed; the amount of asphalt wed between phut the coin type, and mass of surfacing; and tM dlfaction of exposure. Keeping N mind these conuderanons and that on rounalona are intended on the scope at wh;dp a sprcific asphalt must be used, tau following guidelines are provided. XI.1 r,, / includes asphalts that aria relatively Isaceptible to now Ai roof temperatures with good adhesive and "sel(•heating" properties. They ars genitally used in slag. or gravel•wr(aessd roofs on usclinel up to 4.17 96 eh in./11) slope. X 1.2 Type l/ includes asphalts that are niodera ately susceptible to flow 41 root temperatures. They arc generally for use in built•up roof construction on inclines Rain approairt4(.Iy 4.17 16 (eh in/(t) slope to 12.3 96 (1, /a In, /h) slope. X1.3 Tot' fll 1ncJudes asphalts that are rota• rively nonsuseeptib1e to flow at tool temperatures (a use in the cooattuctian of buclt•up roofeonstrttet (ion on Inclines (rout ipptogimaiely 6.f 9fr (1 tn./ (t) slope to 21 % (3 to h) slope, X1 A Type N ncludes asphalts that see genet. a1y noasuseeptible to (low at roof reenpermtutet for use in she aonttntaion of builnup roofing on in. dioes from approiiraately 16.7 % (2 in,/11) scope to i0 % (6 miff) dope. These asphalts may be useful in ants where rotatively high year•round Icmperatunn are eapenertioed. TA► 4..wvim Soon, fig 7 ..I M.rntilt icier •o elfin corms/ the .thief• of tray rl mind rr'Arr rwnrl in twwrne.o• .ire PT FIN ..r.r�.rr(ly Mir A.ndwd Clom a/ Ad wn.+fI +fir rr1►v Ij *t.. .w.+.wwArw at OW mad, aeo.t' nark prod halm nd.• aid oil ,• jirrroonwr r,41 st n j+i w cave v0 Mrr..w ntrwA.i'y 11.1 ar•rd.r t U iii/K+ is nvol., to Mr now bi • wspo aa4 rr(Meer.l rr►rwrmaaff fwd .wit bi vvw, rd awry Art 'ten .o►% rf .►w resin), rrlwr nrpygw•I.t .•.rAOra••n Yaw t+••erKe ivy M►►orl tither j f write+ e/ AU w�Qsrf w #v 4*c.wd inwhi dt MI *odd k N Arm &wigf, am. Knit ra•wwa will moos r.rrylrl tawidwonw el 4 w•nN.r u /NM mimosas, rrrMd'.1 rwe•uirwv, *Awn '.a,• .•.v wvwl I/ rat f ^rl sneer, ra+►owMM &OW tat newer) obit )twins Jw tAQ 4d.i.' ►w..:.•wt imam le vii A$TJ/ C.rMUw w So.•wladt, 1916 R.rr 51,. PAJ.IrHrad. P.. If►I0J. wheel ..1l rrtvd•a • twang nxmikog 164,0 ra..rr.a, fold oar stit1trtiae awe. or err .prr.l is Ike . A STM Saint Of Cinirnwi. 1$ .••3 R .. .1, II } T 0 er ANS •• c1 r1 a F a0 6 a o CITY OF TUKWILA APPROVED . *JUL 1 9, 2002 tabs 'ter l i ill ruama t?�Vt:31 Johns Manville Description FesCant Pius Cant Strip FesCant Plus Cant Strip is manufactured from JM Cant Board, a high density, laminated board made of high strength fibers and expanded periite, FesCent Plus Cant Strips are fabricated into many different cant sizes to meet the needs of the project. The base board that FesCant Plus Cant Strip is manufactured from meets the material requirements of the W (13 mm) polite board in ASTM C 728. Tapered Fesoo Edge Strip Tapered Frisco Edge Strip is manufactured from JM Fosco Board, which is composed of expanded periite, a volcanic ore, and blend= rid with selected binders and fibers. Tapered Frisco Edge Strips are available In standard sites to meet special needs. The base board that Tapered Fosco Edge Strip is manufactured from meets the material requirements of the W (19 mm) partite board in ASTM C 728. Use FesCent Plus Cant Strips provide an excellent way to transition from the dock to the wall of the roof. Because of its high porlite content, FosCont Plus Cont Strip offers far greater fire resistance than conventional wood fiber materials. This feature Is Important to all roofs, but especially oppllceblo to heat weldable modified bitu• mon systems and flashing dotoils. Tapered Frisco Edge Strips ere good for transitloning from mom• brono to nailer or trensitioning from o Taporod Fosco, Tapered E'NRO'Y 2 or Tapered Fosco Foam panel to tho roof level to help promote positive drainage. Because of its porlito content, Tapered Fosco Edge Strips offer far greater fire resistance than conventional wood fiber materials. Typical Physical Properties* Water Absorption, % by Volume - 2 hrs 3.5 max. 1.5 max. ASTM C 209 Compression Resistance 5% Consolidation - psi.,,,..,.,35 (241 kPa) .30 (207 kPa) ASTM C 165 10% Consolidation -psi 50 (345 kPa) 40 (276 kPa) laminar Tensile Strength-psi -.4,9 (33,8 kPa) 7 (48 kPa) ASTM C 209 Flexural Strength -psi 60 (414 kPa) 65 (448 kPa) ASTM C 203 Product Density-pcf 11 =14 (176.224 kg/m') 91144 kg/m') ASTM C 209 Linear Expansion 0.5% max 0,5% max. ASTM C 209 'Meosured on bese board prior to fabrication of finished product, FesCant Plus Cant Strip Tapered Fesco Edge Strip Both FosCant Pius Cent Strips and Tapered Fosco Edge Strips comply with the Environmental Protection Agency Regulation 40 CFR Part 248, "Guideline for Federal Procurement of Building Insulation Products Containing Recovered Motoriots ", es a roily. clad product approved for use on any project using federal funds. FesCent Plus Cant Strips hove et least 35% post•consumor racy clod content, and Tapered Fusco Edge Strips hove et least 26% post•consumor recycled content. Advantages • Excellent fire resistance • Dimensional stability • Strength and handloability • Meats RCRA requirements for recycled content Values Values FesCent us Tapered Fesco Test Cant Strip Edge Strip Method Sixes FesCent Plus Cent Strips are available in 3', 4', 5' and 5W (76, 102, 127 and 146 mm) sizes. Tapered Fesco Edge Strips are available in 6',12',18" and 24' (152, 305, 451 and 610 mm) lengths. CITY OF TUKWiLA APPROVED JUL 19 2002 Kri.) CEO Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS-5049. MaIarkey TECHNICAL PRODUCT DATA SHEET #500 PREMIUM 1TM PLY SHEET Product Use: 0500 Premium 1 Pty Sheet is a high- strength ply sheet suitable for use as an interply in multiply roof sys- tems, This high•strength ply sheet may be used over various combustible and non•conihustihle decks us the initial ply or in conjunction with multiple ply roof systems. Please note precautions for limitations. Precautions: Do not mechanically attach ply sheet to any deck, A base sheet should he specified for mechanical attach. went. Ply sheets are not recommended for cold process application, Malarkey ply sheets require dry storage and pmtec• lion from the weather, Do not apply wet ply sheets, Roof decks should be sound, dry, smooth. meet necessary local requirements and provide positive drainage, Composition and Matorlabt 41500 Premium 1 Ply Sheet is manufactured with pure coating asphalt on tested Malarkey fiberglass mat and treated with a nonstick agent to facilitate unrolling. No mineral release is used, 'A''jili�Nloll Slifidit7�it "Aprovii for uti� iin ill iW%i(d rtyofi ?See Malarkey manual for specified information, TrrYNIPAi_ DATA Typical average properties, 5 square roll: Weight/roll Welght/aquaro Dimensions Lay Linos Breaking Strength 48 Ibs (21.77 kg) 9,6 Ibs, (4.35 kg) 39r/1" wide x 165` tong (1m wide x 50.3m long) 2 ", 9) /I ", 121h" and 18)/4" minimum (50,8 mm, 238.1 mm. 317.5 mm, 476,2 mm) 44 ibs, (19,9 kg) *Winch minimum. both MD & XM Complies with ASTM D 2178.89, Typo IV and listed by FM and Wit Moots or exceeds the requirements of 11L 55 A 7j►pe 01 for asphalt content and minimum weight. Dade County Approval, 0500 Premium 1 Ply Shoot shall ho applied as specified in Malarkey Bullt•tJp Rooftne SYlitelliti manual with a epoclflud baud shoat and /or surfacing. It may be applied in cold weather, Please follow cold weather application and general requirements. HAIIIIAtand Malarkey Roofing Company offers various warrantios to moot specific requirements, Tho motility package includes 5•, l0•, 15. and 20•yoar limited and unlimited coverage, Contact Malarkey Roofing for full details, nouncektizawas Malarkey Roofing has technical assistance available for all phases of built•up roof coverings and requirements. Inspectors are available for consultations, Job site, and final inspections, Contact your local representative and /or Malarkey office for details at 800/545.1191, AyIIIABn nv_ Malarkey 0500 Premium 1 Ply Shoot is available throughout North America and Pacific Rim countries, Consult your nearest Malarkey source for additional information and availability, etrtellYs 10,1097. tivptrxdss sU p iou *ly pbbsli443( . CITY Of TUKWt1A APPROVED JUL 19 2002 As ED i.Dm �jt,,7. Malay TECHNICAL PRODUCT DATA SHEET #502 PREMIUM"' FIBERGLASS MINERAL CAP SHEET Product Use: 1502 Premium Fiberglass Mineral Cap Sheet is a fire =rated (PR) cap sheet manufactured to meet the needs of a conventional, quality buitt•up roofing system. This cap sheet can be applied with hot mopping asphalt or cold process adhesives, `this product is used at a surface sheet for multiple•p1y roof systems. Precautions: 11502 Premium Fiberglass Mineral Cap Sheet requires dry storage and protection from the weather, Do not apply wet cap sheet, Roof decks should be sound, dry. smooth, meet necessary local requirements and provide positive drainage. Composition and Materials: 1502 Premium Plbergless Mineral Cap Sheet is manufactured on tested Malarkey fiberglass mat. The glass mat b impregnated and coated with oxidized asphalt. filled with fire•ret.rd nt fillers and surfaced with ceramic granules for ultraviolet protection and weatherability. I il.flUmida rot ` Approval for use on an fks.r$.d fttofir See Malarkey manual for specified lnforma• tion. T110111 AL DAt4 Typial average properties,1 square roll: Weight/roll Dimensions Granule Adhesion Thlokness 78 lbs. (214 kg) 39)/s" wide x 33' long (lm wide x 10,0m long) 0.5 gram lois 90 mils Listed by UL. PM and Wil. Complies with UL 3M Type 133, UL 33R 33. Meets or eximedi ASTM D.3909.91. Dade County Approval, Pedant Spec SS R 630 D Ctau 3. AZILICATIOlinfICILIdiln 0502 Premium Piberglau Minuet Cap Sheet shall be applied as specified in the qt ukdy Dunhill) Roofing Systems manual with specified base shoot and/or imply shoots. It may be applied in cold weather, Please follow cold weather upplivatlon and general requirements. Hams= Malarkey Roofing Company offers various warranties to moot specific requirements. The warranty package includes S.. 10•, 13• and 20•year limited and unlimited coverage. Contact Malarkey Roofing for full details, TacirNIPAL Aeavicu Malarkey Roofing bas technical assistance available for all phases of built.up roof coverings and requirements, Inspectors aro available for consultations, job site, and final inspections, Contact your local representative and/or Malarkey office for details at 800/545.1191. MAUI= Malarkey 0302 Premium Mineral Fiberglass Cap Sheet is available throughout North America and the Pacific Rim coun• trim, Consult your nearest Malarkey source for additional information and avellability. Etkcuw►Q•t6a7. &vp cdccrlrpfoivwbpvb41$443u* CITY Of TUKWILA APPROVED JUL 19 2002 ASP.OftD :rvvl.M.WuWE Malarkey TECHNICAL PRODUCT DATA SHEET #601 HIGH PERFORMANCE PREMIUM SBS CAP SHEET • WITH POLYGLASS•MAT Product Uses #601 High Performance Premium SAS Cap Sheet with Polyglass mat is a tire•rated (PR) mineral cap sheet manufactured to meet the needs of a high performance, quality built•up roofing system. This cap sheet ran he applied with hot mopping asphalt or cold process adhesives, 'Phis product is used as a surface sheet for multiple -ply roof systems, Precautions: #601 High Performance Premium SAS Cap Sheet with Polygless mat require* dry storage and protection from the weather. Do not apply wet cap sheet. Roof decks should be sound, dry, smooth. meet necessary local requirements and provide positive drainage, Composition and Materials: #601 High Performance Premium SAS Cap Sheet with Polyglass mat is manufactured on Malarkey polyester /`lass fiber (Polyglass mat with a random pattern of wet laid polyester fibers with resin acrd latex). The Polyglots mat is impregnated and coated with SAS modified uphill filled with a fire retardant stabilizer and surfaced with ceramic granules for ultraviolet protection and weatherability. Appirov11 for use on 111 fk. n .d built-up roofs* Please consult the Malarkey Manual for speci- fied intorrnallun. Typical average properties, 4' selvage. 1 square roll: Weight/roll Dimensions Granule Adhulon T hickneu Braking Strength OM (.18•C) breaking Strength IV 77'P (2'C) Elongation @ Break Ultimate Elongation m► Sample Break Thor Resistance 102 lbs. (46.3 kg) 39)/s" wide x 34' long (1m wide x 10,3m long) 0.5 gram lose 120 mils MD: 123 Ibs. *P/In. MD: 80 lbs. *P /in. MD: 4% MD: 25% MD: 98 Ibs. *P /in, XM: 1001111. *P /in, XM: 40 Ihs, *P /in. XM: 4% XM: 40% XM: 90 Ihs, *P /in. The above reaulu per ASTM D 5147.91. Moots or exceeds ASTM D 3909.91. Listed by PM, uL and WH. Dade County Approval, Federal Spec SS R 630 D Class 3. rittLIGOIKEABGEBllit 0601 High Performance Premium SAS Cep Sheet with Polyglass mat shell be applied as specified in the Wham, Built-up Booflns Swami manual with specified base shoot and interply sheets. It may be applied in cold weather. Please follow cold weather application and general requirements. Mum= Malarkey Roofing Company offers various warranties to meet specific requirements. Warranty package includes 5.. 10 -. 15. and 20.year limited and unlimited coverage, Contact Malarkey Roofing for full details. Inatinifili8=86 Malarkey Roofing has technical assistance available for all phases of built•up roof coverings and requirements, Inspectors are available for consultations, joh•site and final inspections. Contact your local representative and /or Malarkey office for details at 1- 800.545.1191. ,4hvAILAIII=L rrY Malarkey #601 High Performance Premium Polyglass SAS Cap Sheet is available throughout North America and Pacific Rim countries. Contact your nearest Malarkey source for more information and availahility. CITY Of TUKWIU1 APPROVED Molts 10.16.97. Supersedes ad ptrriousty published dos. JUL 1 9 2002 ASNOa �LL *1G EFIS o I019741),WICE 1 ✓U 1 Johns Manville Description Bestile Industrial Roof Cement is a premium grade mastic designed for use in the construction of professional roof 'lashings and details. It is a blend of selected asphalts, non-asbestos fibers, selected fillers and petroleum solvents, This is a high quality prod- uct, supplied In a smooth, easy-working consistency, which adheres to wet and dry surfaces. Bestile Industrial Roof Cement resists slumping yet remains plastic, Therefore, it may be used on both vertical and horizontal surfaces, It has a high resistance to weathering and provides excellent durability against the stresses and wear to which flashing adhesives are normally exposed. Use Goalie industrial Roof Convent is dosignod as a watorproof adhesive componont of beso fleshings, projection and penetration fleshings for commorcial/industrlat roofing systoms, It is also on oxcotlont soalarrt for countorflashings. It is used whoro dissimilar materials must bo Joined and sealed watortight. Booth Industrial Roof Camont may bo nod as a flashing adhosivo on both vortical and horizontal surfaces. It may bo used for ropairing bituminous roof surfaces and for wstorproofing and flashing whoro a heavy duty product is roquirod, Bocauso of Its ability to bond to damp end wot surfaces, It may be used for emergency repairs. It has tho necessary body, con• sistoncy and rosillonoy to maintain a strong, watorproof bond during varying temperature and woother conditions. Caution Combustible, Booth Industrial Roof Comont contains potroloum distillate, To minimize risks; KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAME • AVOID PROLONGED CONTACT WITH SKIN • AVOID PROLONGED OR REPEATED BREATHING OF VAPOR • AVOID CONTACT WITH EYES • DO NOT TAKE INTERNALLY • USE WITH ADEQUATE VENTILATION • KEEP CONTAINER CLOSED WHEN NOT IN USE • KEEP OUT OF REACH OF CHILDREN. Pr milt( t , BestiletM Industrial Roof Cement Application All surfecos must be cloan and free of oil, groeso, rust, scale, Iooso point, dirt and dobris, Porous surfaces roqulro priming with JM Concroto Primer. Primer must be allowed to dry prior to tho applica- tion of Bostllo Industrial Roof Comont. Bestile Industrial Roof Comont is oppllod with a trowel, In a thlcknoss of W (3 mm). Do not apply in thickness oxcooding %' (8 mml. Apply comont liberally in joint areas, scams or cracks. Work tho comont to a foothor odgo to provide a smooth transition and facilitate dralnogo. Tho comont should be roinforcod with roofing foil, bolo flashing shoots or gloss fabric, For bast rosults In cold woother, storo unoponod contalnors in a worm aroo for of toast 24 hours prior to application. Equipment and tools con bo cleaned with korosono or minoral spirits immodi• otoly oftor use. Use oxtromo coro when handling solvonts. Coverage Boothe Industrial Roof Comont should bo troweled onto tho sur- face to which fleshings oro to bo odhorod In approximately r4' (3 mm) thick layer, Oo not apply thicker than W (8 mm). Ono golion of material will covor opproximotoly 14 square foot (0.34 m' /lltor). Typical Physical Properties Material meets the requirements of ASTM 0 4558, Type I. Color Black Solids Content 75.78% by Weight Weight por Galion 10.0 =10.2 ibs (1,20 =1.22 kg /sitar) Drying Time (7011219C], 50 %RH) B Hours Shelf Life Indefinite in Airtight Container Coverage (W (3 mm) thickness) 14 sq, ft, per gallon (0.34 m' /liter) Packaging 5 gallon (18.9 liter) pails. CITY Of TIJKWILA APPROVED JUL 1 9 202 Li) Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS•2029. Og Yjnd Johns Manville Prilf11j( Description Concrete Primer is a thin brushing, cut•back asphalt primer, Use Concrete Primer is used to prime concrete roof decks, brick and other masonry used in parapets and walls to which fleshings are to be applied, It prepares these surfaces to receive hot asphalt or cold asphaltic cements and ensures good adhesion, Concrete Primer also makes an excellent primer for metal edge strips and other metal roof components which are to receive asphaltic coatings or cements. To minimize risk: AVOID PROLONGED OR REPEATED BREATHING OF VAPOR • AVOID CONTACT WITH EYES • 00 NOT TAKE INTER- NALLY • USE WITH ADEQUATE VENTILATION • KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAME • KEEP CONTAINER CLOSED WHEN NOT IN USE • KEEP OUT OF REACH OF CHILDREN Application Apply Concrete Primer by brush, roller, or spray to surfaces which have boon cleaned of dirt and loose materiel. Allow to dry thoroughly before proceeding with thn oppiicotton of the roofing system. Concrete Primer Concrete Primer can be used at any time of the year. In weather below 401 (4•C), keep in a warm area (701 (21•C)) until reedy to use, to make application easier, The Primer is ready for use right out of the container and should not be dilutod. Material moots the requirements of ASTM D 41. Coverage One potion (3.8 liters) covers approximately 100 square fact (9.29 m') of roof area, Packaging 5 gallon 1181 liter) polls and 55 gollon (208.2 liter) drums. CITY OF TIJKWILA APPROVED JUL 19 2002 AS wic.G Refer to the Material Safety Data Sheet and Product Label prior to using this product. For an identical copy of this data sheet ask for RS-2065, "SINCE 1919" July 16, 2002 HAIGHT ROOFING COMPANY, INC. Mailing Address: P.O. Box 70150, Seattle. WA 98107 Area Code: (206) 784.8414 INDUSTRIAL - COMMERCIAL - ROOFING and SHEET METAL WORK Fax: (206) 784 -1058 INSULATING CONCRETE ROOFS DECKS REROOFING SPECIALISTS City of Tukwila Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Commercial Reroof 1161 -1177 Andover Park West, Bldg, "B" 1141 -1159 Andover Park West, Bldg. "C" MTV OFWILA BTUK JUL 17 2002 PERMIT CENTS I The existing roof system on the above referenced commercial building consists of a fiberglass base sheet attached to the structural roof decking (plywood), followed by three layers of fiberglass ply sheets set in roofing asphalt, The ply sheets were then glazed with an additional mopping of roofing asphalt, Others MVO added minor and insignificant additional materials at random areas in the effort to repair apparent roof leak problems, The new roof system will be applied following tear off and removal of the existing roof membrane components down to the top surface of the existing structural plywood roof deck and will consist ofl„j- 9tpolyisocyanurate insulation covered with a one -half inch perlite cover- board, mechanically attached with screws and plates, followed by three layers of fiberglass ply sheets set in roofing asphalt. The roof will be finished using mineral surface fiberglass capsheet set in roofing asphalt. Base flashings will consist of two ply's of roofing felt set in roofing asphalt covered with a mineral surface capsheet set in roofing asphalt. Malarkey Roofing Company in Portland, Oregon manufactures the new roof system materials, The manufacturer's roof system specification is M4 -WU- BHA -H, �� It c0 eVA Sincerely, Haight ; fing Company, Inc., Chuck Mahlum Project Manager CITY Of TUMNIU VW' �l1el��. APPROVED JUL 19 2002 AS WItU Fug c vtiitO MIO. 10 Members: Western States Roofing Contractors Association / National Roofing Contractors Association Washington State Contractors Registration Number HA- IG- HR- C269QK PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M102 -109 DATE: 07 -17 -02 PROJECT NAME: .. Southcenter West Bus Park SITE ADDRESS: 1141 Andover. pIOW. - Bldg .,.__. .Original Plan Submittal Response to Incomplete Letter #_ _Response to Correction Letter # jtevision # After Permit Is Issued Building Division kJ Fire Preven n"% Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator go, DETERMINATION OF COMPL TtNESS: (Tues., Thurs.) Complete E Comments: Incomplete ❑ DUE DATE: Q7 -'I -O2 Not ApplIctible ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined Incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:, TUES /THURS ROUTING: Please Route d Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: ❑ UOL &�RECO: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE :ALM:am Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2.28 -02 1 it 1