Loading...
HomeMy WebLinkAboutPermit MI97-0068 - THORNDYKE ELEMENTARY SCHOOL - REROOFCity of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MISCELLANEOUS PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 004200 -0280 Address: 4415 S 150 ST Suite No: Location: Category: ASCH Type: MISCPERM Zoning: LDR Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: 125 Wetlands: Contractor License No: OCCUPANT OWNER CONTRACTOR CONTACT Permit No: MI97 -0068 Status: ISSUED Issued: 06/02/1997 Expires: 11/29/1997 Occupancy: SCHOOL UBC: 1994 Fire Protection: .0 South: .0 East: .0 West: .0 Sewer: VAL VUE Slopes: Y Streams: SCHOLF*211K5 THORNDYKE ELEMENTARY SCHOOL 4415:S 150 ST, TUKWILA, WA 98168 SOUTH CENTRAL SCH DIST 406 4640 S 144TH ST, TUKWILA WA 98168 SCHOLTEN ROOFING INC. 7157 GUIDE MERIDIAN, LYNDEN, WA 98264 KEVIN FUHRER 4640 S 144 ST, TUKWILA, WA 98168 **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * *A * * ** Permit Description: APPLY STEVENS HI -TUFF ROOF SYSTEM OVER EXISTING ROOF. **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 100,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: ****************************************** k********** * * ** * * * * * * * * * * * * * * *k * * * * * * * *** TOTAL DEVELOPMENT PERMIT. FEES: $ 891.75 **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Phone: 360.398 -8484 Phone: 206 901 -8000 Permit Center Authorized Signature:_ x614,2a_ Date: I hereby certify that 1 have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work.-, I am authorized to sign for and obtain this development p rmit. Signature J — � f L Date: '! �►�� � :c -- l f Print Name: _�•,- C . This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY,`-OF TUKWILA. • Address: 4415 Suite Tenant Status: ISSUED Type: MI SPERM Applled: 05/28/1997 Parcel #: :004200 -0280. Issued: 06/02/1997 k****** er.m it . No: . MI97, -0068 Per mit':`Conditinris; changes 1 1 1 be :;made to the • scope. of work Unless approved by, Tui;wila:'Suiiding pivisicrt.{ 011 permfts, inspe ction; ;reco`r'ds`, an,d °;i:app.rroved plans, shall a ai lab1e at the or to the s-tarrt of any.: con atruction. These' dcc urnents sane to be niaintairre,d., nd avai able` uriti 1 t jna,1 'insper tiioh iap'proval is $t anted.` A,stat the` rci`bfthg\ contractor Jer7f'ying' fire 4 4 '� re'tar-dant c,7 ass ct rti±oof vi 11 nb,e�. required prf'rrr ;:'i'o 1nspe,ct 1o' ;�(see at'tached procedure) .." ` s Val idit F ;.of. P. r•nti >t5 The iss "ance of a permit or' approval of plans.,� ;sp'ecificatians, and coriip.uFtat•ions shall not.tbe .con- stir ue4 .to ;�be a permit for,1,! o.r an approval of, any ,vlulatl'on of afly poi ,the pro'v i s i a s ot`,.'the b:u'i i d i ng code ar,.of other ;A;.or d ti:ance `•of the '7; jurisdiction. No permit Ares „umin,g :9 y tj: to vh 1ate or` ;cancel ='the provisions ot;; thl codWfsha11 be valid,, , ,' t! • Permit No: MI97 -0068 Project Name: CITY OF TUKWILA • REROOF CONDITIONS THORNDYKE ELEMENTARY SCHOOL Address: 4415 5 150 ST Suite: kkkkk*'. k** •kk *k•k•k * * * ** * *k * *k *rk•kk.kk k* kkk*,*. 4*` k; k;, k•*** k**• k• k *kk *•* *kkk'kk• **•.4 * sit •k•k *•F•kk THE FOLLOWING CONDlilliF4S. WILL; APPLY TO..'RE -ROOF' PERMIT . 1 . All re-rooting ,:,,pro:iects wi l.l•. be .,aacompl i'�hed `in compliance with ix Append' Chapter 15 of the Un i f ornr Bu i l d i nd :Code. (Op. 2. Inspect i ons'r,, w. °roof coverings':ih'el l not 'be applied without 'tiret:`. ;6btai »,ing a pre roofing, inspection from the Biii.;lding •'-' fD1;v'is <i,on;_and written approva1 from the Build.ing:.Tnspe.tar. The p,re- rooting inspection shall, pay particular .a:ttention to evidence of accumulation of- ;hater.',. Where extensive pond,ing s of water i apparent,'; an anaiysi,:: of 'the root structure. for oor!l.p,1 ianoe wi G.h.. Sect1on •15(}6; UDC, shall be macde, and correcr'.ive measures, ,such as relocation of root drains* 4,;fGti'ppers, ra,s l op•i`ng of the • roof or structural changie ti, aha l l '.;; be `'accompl1st ed. Art:' inspection•• covering the above l is,t;e i tpp,1 . `prepa, ed +:•by'a qualii,tied special inspector, es \ deX,eriiiin;ed by the Building'.Officlal,' may be accepted In lieu of ,the',,pre- inspection by the B611d•ing Inspector. '; fir`ia1 inspection and approval shall ,be obtained from the ;Bu.i l d i ng Division when the re- rooting ts;; complete . As a 'c'ondition, :ot the final inspection:fo'rti roots, that require a tire, retar,dant 'root covering under the provisions' of Table 15-A,"„ 1994 8C, the - rout. • i nstal l er' shall provide the inspector with a written statement indicating 'the following (or something similar) I HAVE INSTALLED A •ROOF.: MEMBRANE 'ASSEMBLYs, INCLUDING'' IN'3ULATION IF APPLICABLE, CONSISTING OFD .(MANUFACTURER ),,.SPECIFICATION # - - -_t DATA OR ENCLOSED, WHICH MEETS", OR ;' EXCEEDS,. THE•:. REQUIREMENTS FOR CLAS'S A OR CLASS B ROOFS. THIS ROOF WAS INSTALLED AT (ADDRESS) , UNDER CITY OF TUKWILA PERMIT NO. (The statement shall include the name of the roofing company that installed the roof, signature of installer and date.) CITY OF TUKWILA Permit Centel 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. Project Name/Tenant: i> Thorndyke auc— '7'>>kw4l•Element Schoole"'Reroof Value of Construction: Approx. $ 9f�, 140,r iQpa� Site Address: 4415 S. 150th St. City State /Zip: Tukwila 9816: Tax Parcel Number: 4, ,. 7,-,61") _t)2 Address: Property Owner: S. h Central School District Phone: 901 -8000 0 Water Street Address: 4640 S. 144th St. City State /Zip: Tukwila 98168 Fax #: 901 -8016 • Contact Person: .- a . - Phone:; 901 -8000 eli.41,0t?► Street Address: dAdn q 1ddth St City State /Zip: Tiikwi1a 981.: Fax #: 901 -8016 Ph e (?3% ) 398 -8484 Contractor: Scholten Roofing Inc. Street Address: 7157 Guide Meridian Rd. City State /Zip: Lynden, WA 9826 Fax #: (360) 398 -2857 Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS;PERMI7.REVIEIN AND.•AP.PROVAL' REQUESTED: (TO BEFILLED OUT BYAPPLICANT) Description of work to be done: _ _ 11 — Y 11 .. - 11 - - / • - 11 Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and stora • e location on se • agate 8 1/2 X 11 • aver indicatin. • uantities & Material Safet Data Sheets • Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead/Docks ►'•1 Commercial Reroof ❑ Demolition ❑ Fence ❑ Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting APPLICANT %REQUEST:.FOR:MISCELLANEOUS PUBLIC WORKS PERMITS'," Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public Cl Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s : Est. quantity: gal Schedule: Moving Oversized Load/Hauling MONTHLY SERVICE BILLINGS. TO :_ ' . Name: 1 Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER "METER: DEPOSI T /REFUND 'BILLING: Name: Phone: Address: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 5=a--T) ) Date application expires: (Al Application tai of by: (initials) AATCr'DAAT nr\r• 7/11 /aL ALL MISCELLANEOUS PE T APPLICATIONS MUST BE SUB ED WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER .(P.E.) SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW 'Above Ground Tanks/Water`:Tanks Supported directly upon•:grade : exceeding 5 ;000`gailons'and:a'.ratio of height.to diameter or width which exceeds' °2 1 Submit ,checklist:;=. No :::> • Antennas /Satellite Dishes; : Submit checklist;-. Awnings /Cafopies -,,No sighage Commercial`Tenant Improvement• Bulkhead/Dock Submit checklist : =1 Commercial-Reroofi Submit'checklist;;::. Demolition. Subrpit checklist NO; :; M =3 M;3a'.>, rj Fences - Over 6 feet in Height Submit'checklist: No :"' in Land Altering/Grading/Preloads Submit checklist;:,. No:: M- • Loading .Decks. Coi1'imercjal: rl"enant`,I�prayement < 'Permit', r Submit :chiecklist Noi `1:1:7. :Mechanical'(Residential;& Commercial) Mlsceilaneous-Public WorksjPerrnits ".Submit�'ctieckiist , `' Residential :only • .Subrrmitchecklist';? �H- Manufactured. . Housing;(RED'INSIGNIA ONLY) Sybrnit :checklist:;`.: Moving Oversized: Load /Hauling Submit:checklist :� No:: M75s' r 'Parking Lots : Submit checklist ;;; No :, "M -4 • Residentia[Reroof - • Exempt with following exception: If roof.structure •to'be.repairedor replaced ResidentialBuilding Permit::: Submit che`ckiist:. No:. M -6,. in Retaining WaIIs- Over4 feet in height Submit checklist . No:. M41;f, in Temporary Facilities Submit checklist; : o ;:'M- • Temporary Pedestrian Protection/ExitSystems Submit ,cheOkiist , No:''M 4 rn Tree Cutting' Submit checklist No: M-?'. El Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent. If the applicant is other than the, owner,' registered architect/engineer, ,or contractor. licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this perinit'applioation and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING .OWN .0RNUT• 0 -I - • A, Signature: , �.i sV � L - Date: Ma 5, 1997 Print name: KP_V] n A. Ftiuhrer Phone : 901 -8000 Fax #: 901 -8016 Address: 4640 S. 144th St. City /Stale /Zip: Tukwila, WA. 98168 M1 rPMT.nnc 7nh /nr, ********* k*****k**** *kk*****A **(`*�k'* ** irk **1,***k ****Akk**** ***** CITY CJE TUKWILA. NA 110,171—. i�d`S� TRANSMIT ** * * * * * * **kA * * * * * ** **` ** ** * * k * *k * *kkk * ** * ** ** * * * * * *y4A TRANaMIT Number:.R9700587 Amount:. 891.75.05/28/97 09:08 •.Payment Method : CHECK Notation:' SOUTH CENTRAL In i t: SLl3 Permit No.: 34197.0068 Type: MISCPERM MISCELLANEOUS PERMIT. Parcel No: 004200 -0280 cite Address. 4415.5 150 ST Total Fees: . 891.7; This Pbvment 891.75 Total ALL Pmts: 891.75. Balance: .AU * * * * * * * * **** * **k ***; ** 4 ***4*** *** *•k * * * * ** **444*** * * *** * * * *** *A• * ** Account Coda 000/322.100 000/3035 »904 .D.eacription. I3lI,ILUING - NC)NRE8 STATE EUILI)ING SURCHARGE Amount 887.25 4.50 IN SPEC 110N NO, INSPECTION RECORD Retain a copy with per(` CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 70 Project: �11... .... Type of inspection: r i Addres . , sz, ,1 30 Date called: Date wanted: / �r( Z --r'fl :,. ;; p.m. Special Instruct ons: 4e( UU u b= OO �---, Requester: Phone No.: Approved per applicable codes, Corrections required prior to approval, co ENTS: Viµ.. 1 ...°ill... • Inspector l ,I. YV IN1..�. Date: 542.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee .must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection., rl INSP TI N O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 INSPECTION RECD: Retain a copy with pe L. Okk I• AT('7- QDL ' PERMIT NO, (206) 431 -3670 PrQJect: Type of spe (ion. Address: LHISS■ I _st. Date cal ed: i. -R-97 Date wanted. 1,-) -9 - `'17 Special instructions: (a, p.m. Requester: L- CU4116k._ Phone No.: [� Approved per applicable codes. COMMENTS: [] Corrections required prior to approval. •._, 72 Inspector i Date: $4 . + I INSPECTION EE REO IRED. Prior to inspection, f : e must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. ♦ . ' tMRVi.14 INSPECTION RECO =h~ Retain a copy with permit INSPECTION NO, CITY OF TUKWILA. BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431- 70 Project `i h(__- Type of in ction: Date cal ed: � / Address, Special Instructions: \ 't. Date wanted: / - '`?7 a,m. p.m. Requester: .Phone No.: Approved per applicable codes, Corrections required prior to approval. COMMENTS: Inspector: r! a /41 /A► $42,0 INSPECTION E REQUIRED. Prior to inspection, fee, must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 1 Y,; OCT 03 '97 12 :12PM 7,IKWILR DCD/PW rl s ur ^. .T.1 r!a: We' rWa? '!'ei,..01.7 r6 CITY OF TUKWILA Department of Community Development Bullding Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone; (206) 431 -3670 P.2/2 REVISION SUBMITTAL DATE: OCTOBER 3, 1997 PLAN CHECK/PERMIT NUMBER: MI 97'0068 THORNDYKE ELEMENTARY SCHOOL, ROOF FRAMING PROJEC'r NAME: 4415 SOUTH 150TH STREET, TUKWILA WA 98168 PROJECT ADDRESS: CONTACT PERSON: BILL VAN DE BOGERT /LAURA ,SMI,ONE: (206) 901 -8012 REVISION SUMMARY:. SUPPORT ROOF STRUCTURE OF GYMNASIUM PER OUTLINED BY GREG GILDA OF RSP EQE. SHEET NUMBER(S) "Cloud" .2r highlight all areas of revisions and date revisions. SUBMITTED TO: DAVE LARSON CITY OF T TUKWI OCT 0.3 1997 PERMIT CENTER 3t19/96 • FILE COPY - I e. Flan C;:: • . , ;_; pct omission:; P'. 3 nc; authorize the vlolatIcr, L. c. ' • ' chi or manna Ehmeltaj of carat; actor's a; / c; cpproved plans Ocknovliad9ed. Dato Permit No. SHEET NUMBER(S) "Cloud" .2r highlight all areas of revisions and date revisions. SUBMITTED TO: DAVE LARSON CITY OF T TUKWI OCT 0.3 1997 PERMIT CENTER 3t19/96 • mutrairdi- Project Data RECEIVED CITY OF TUKWILA OCT 031997 PERMIT CENTER To South Central School District DATE August 27, 1997 4640 South 144th Street (Revised: October 1, 1997) Tukwila, WA 98168 PROJECT Thorndyke & Tukwila Elementary School ATTN Bill Van De Bogert / Laura Smith - Roof Framing Review PROJECT NO. 150626.01 BY Greg Gilda Memorandum RE: Roof Framing Strengthening We have completed our review of the existing roof framing for Thorndyke & Tukwila Elementary School. The purpose of the review was to determine the adequacy of the framing to support a new roof membrane and 2" of rigid insulation. Per our previous discussions and reports, the review did identify the header beam between the stage and gymnasium as well as the main gymnasium beams as being significantly deficient for the total design loads. Per our discussions and site visits on August 25 and September 29, these main beams do not have intermediate supports at the stage partition wall (this is consistent with our review of the provided plans). Per our discussions, we have enclosed the sketches SKO -A, SKI, SK2 and SK3 to address the condition necessary to shore these existing beams for Thorndyke Elementary School. These solutions are provided as temporary solutions (two to five years) in anticipation of the demolition of both schools. Should the life expectancy of these solutions be extended, a more permanent solution should be used. Tukwila Elementary School is similar to Thorndyke and the framing will require similar supports. The gymnasium and stage floor is built over a crawl space and the attached sketches SKO -B, SKI, SK3, and SK4 address the repair procedures for this building. If you have any questions or need any additional information, please call our office. Thank you. RECEIVED CITY OF TUKWILA OCT 031997 PERMIT CENTER �EF�r 5K2 For Pa'7T orJ,jEC -r' To Loot . PL a>J %4 ' -o " • An EQE International Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone 206.624.8687, Fax 206.624.826E IHCIfV■i t21 project c, GI -t o o L. date' rsp no. V.;1, IS4 ALA yVnN:VOSA670, "R+ . . . i 1 .. ,. i..1. : r 1 I { { t t• : : t . 1 I . ; 11 1. 1. { : I I ■ •i' !. I• }:"!• :1 j t. 1 'r{ . 1 I 1 ; : . : ' .. . 1 1 j' l i ! 1 . ! . • 1 1 ..,�,,,1,.�. • : : 1 } 1 1n ..I. ........................ ,. 1 ' •1 1' x r • , i : . t ' � + i .. ; , ! ! . 1 1 r 1 • ! ' ' Cam,,, 4. p. • it ,a01'�t�Z� �1 ��/�' i t i '...i_i_..:_. • :' 1 i, I t s 1 1 I , a i �- 7- t.; • I , • i at } , t i 3 ,. I . . • • i • , ' t . . . . : . ! , 1 . i i. __..:._ _......._. _ ...... - - -- _ ..........t ;. . :_ .... :.... .. .... : • • • • BUILT -up toLu," _. _...... __._..... _ ......_ .. __ .._.. .. N\-,I. _ . .. _. 4) ZX.. 1... n.1CG :. _ Srvp CA..'S, 4� ..... . - :..... (HFti•2 -02: g.E.rT ) ...:... '.. �..:_._... -__ .... r,.• ... .:‘.. �'Lyrvroo.L :..s1h.'kl- • s .'� ..:... . 3E LOw G YeA n1 . ism'. ..... - -... _.. _ (? Lv 6f?-Tid • _ . -. RECEIVED .... - .C1T'y OF TUKWICA ... C.r. :o.'. 34 97 ..... _ ... . . ., .... • _.. ......_..... .. .. ._ .. .. • - PERMIT 'CENTER" Aa EQE lnternatiotial Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone 206.624.8687, Fax 206.624.8268 7b1r4 AVKE- t 71.441^1t(41- r EUTNL/ project FA-G g / A-10- 0/24117 date GJG rsp no. .57<j ehAm • . • • ex(- , frP • /// , I Yr-vet/Li v,-rvf eosr x ot-s" Cz.) 'Yvis /134 114C) — t—rS (cA. if_ 7704664 ilfitt 3/41"0 K'14/1‘ gam Cc nu av) RECEIVED CITY OF TUKWILA • OCT 031997 PERMIT CENTER 1 ••• •••• L. • .• • - • ^.. • , .• • An EQE International Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone 206.624.8687, Fax 206.624.8268 / 2 , t 4 t a < 5 ; d T C 1 4 . 4 1 / 1 — EL 6'/„/ Ti y project QrPAIPL PAC lei'? date rsp no. n n 0. 0 tr SI% i 1 Illo d 2 . ��A'� G Cam) STMCIER I3 ANj Ofw 5v,a, . wr o >j () 2X$ 1 iM 5Yki5 4.(1) Z )($. KYJr. 57tdb REf 1;1Z sK -1 rocl% L. km5Pc qtRAPE ,NJtb NAI L4 1(T Lcc !G.. - is .,n ••,6:444..S.N1.Nrgh „titidti:44 x.it:iM.r •Nltv.•Sli•moSoW it.. +NHm+ »Nwi..V0.4•••.ayu,•∎∎•0 +,: ,uF+'nolvii•r•y..••∎. •14.14n.<vrva.uµ.um v.VSSditNN IMMO RECEIVED CITY OF TUKWILA OCT 0'31997 �J ti�J p 0 z2 r ' PERMIT CENTER 2.” IJh-W 4 X FLockini6r X f 1-O" L.pNG 1:•nI ,'TH ,.JrvJ po5j (2) 3 /1'10X O' -6'1 r-)iv /1c,kC (� ) Loots 101415 ,• o • • A -A /(), •1 . ,n It t /4111 (�- I I Co 2.Act-op- t SIGAJ Co KJ to (7)4%15 HII T ofiu "r.< 14/ 31" EM6'o0 An EQE International Company 1411 4th Avenue Building, Suite•500 "S eattlo ;'Washiagtori-98101"Phoife 206;624.8687, Fax 206.624.8268 sue, , 'ft- 11 Sr►ln0 project Pi dale rsp no, I Z 'D MC: +.nn: it, <t. 1. ...:1;.r,14'i.'E0PeeI 4,41957MA.(5t1 24 YJSn.UY•Yvore i CITY C3,-' TUKWILA ter- Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 CITY OF ETUKWILA SEP 1 5 1997 PERMIT CENTER REVISION SUBMITTAL DATE: SEPTEMBER 15, 1997 PROJECT NAME: _, PROJECT ADDRESS: 4415 SOUTH 150TH STREET, TUKWILA WA 98168 BI I,I. VAN DE BOCERT /LAURA SMITH (20() 901-3012 CONTACT PERSON: PHONE: PLAN CHECK/PERMIT NUMBER: _0112j. T1IORNDYKI3 ELEMENTARY SCHOOL., ROOF FRAMING -.aptaS SUPPORT ROOF STRUCTURE: OF GYMNAST UM PER REVISION SUMMARY: _ OUTLINED LINED BY GREG GII.IDA OF RSP Ec1r . Callod 1u,+�t��ILIeL97 SHEET NUMBER(S) 4 "Cloud" or highlight all areas of revisions find date revisions. (DAVE LARSON SUBMITTED TO: Project Data To South Central School District 4240 South 144th Street Tukwila, WA 98168 ATM Bill Van De Bogert / Laura Smith .■ mursorge- DATE August 27, 1997 (Revised: September 3, 1997) PROJECT Thorndyke Elementary School - Roof Framing Review PROJECT NO. 150626.01 BY Greg Gilda Memorandum RE: Roof Framing Strengthening We have completed our review of the existing roof framing for Thorndyke Elementary School. The purpose of the review was to determine the adequacy of the framing to support a new roof membrane and 2" of rigid insulation. Per our previous discussions and reports, the review did identify the header beam between the stage and gymnasium as well as the main gymnasium beams as being significantly deficient for the total design loads. Per our discussions and site visit on August 25, these main beams do not have intermediate supports at the stage partition wall (this is consistent with our review of the provided plans). Per our discussions, we have enclosed the sketches SKO -A, SKI and SK2 to address the two conditions necessary to shore these existing beams. These solutions are provided as temporary solutions (two to Live years) in anticipation of the demolition of both schools. Should the life expectancy of these solutions be extended, a more permanent solution should be used. It is our understanding that Tukwila Elementary is identical to Thorndyke and that the framing would require the same supports. (The stage at Tukwila Elementary is currently used and the attached sketches SKO -B, SKI, SK2, and SK3 address the repair procedures for this building.) If you have any questions or need any additional information, please call our office. Thank you. CITY OF TUKWILA APPROVED SEP 1 5 1997 AS NO i 1:U RECEIVED CITY OF TUKWILA NG DIVISION SEP 1 51997 PERMIT CENTER \\eqe sea_ 01\ sys\ wp\ staff\gjg \thorndyk \thornpm3.rtf • PLAT An EQE International Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone.206.624.8687, Fax 206.624.8268 Tfiof A J! Y K r _ £ crf�l F I V y project GI/ 2/q1 date rsp no. — C'//4M' S/ )2C STR E. A/67746P IWC 6-36 SK O- A detirn Sheet i f S o 4t#‘4��\ � t i.' 01� \ �,F r h PLAT An EQE International Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone.206.624.8687, Fax 206.624.8268 Tfiof A J! Y K r _ £ crf�l F I V y project GI/ 2/q1 date rsp no. — C'//4M' S/ )2C STR E. A/67746P IWC 6-36 SK O- A detirn Sheet An EQE lnternational Company 1411 4th Avenue Building, Suite 500 .Seattle, Washington 98101 Phone'206.624.8687, Fax 206.624.8268 wearri- . 7Ukw/LA L�r1FfMrAnv project - C-- ` /MNAS► v.-, gotyp Srfaia6 -atgNi rsp no. sheet Ewsr- SS-P; /Ltrcrr- PKG. f___,� -- (IVY r(4,8 �-a sip - s = t ti \:■.\-1•. A Cie. i.) COL ., - ; -� ..� G /,,4 t� LJCr'TIc.:S,i. «Ftr An EQE International Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone 206.624.8687, Fax 206.624,8268 % l�J(Zm A' /Kcr. %'!.;� ;• - ,� ! 1s /� Ai 7e-/ 5/2G l q( 7 project • • FA/'''.C- , • /2 fit 2 • date rsp no. k. design sheet l itbc rz (2,'JIt --r- f f&sr 4.. t.1 /i. %U'_S" /75A. 51 L. .y '-/ Cz.1 ' " 1t% 7-•,Zv - /)-TS • -G} .!:L A,,,c 3/4/ 175 Ke./ G��, f (C res is IF\ • '7. 7• • • • LUCK ,'7 ✓iJ_� rJ) % ,3 =O's ,7/ i^ AEA. 7'' . (') vxexY' -O4 F .ECS. 7G: �A �• ti.10T" 7v Scrc;_ An EQE International Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone 206.624.8687, Fax 206,624,8268 DIU/21,rLyK5 d %vi L »L,c cL,1./ c/J 7; / project —f,,e /i G. REPA1t2- Q�G,l��y date design rsp no. sheet An EQE International Company 1411 4th Avenue Building, Suite 500 Seattle, Washington 98101 Phone 206,624.8687, Fax 2 06.624.8268 `Trnier,l b' � • Srt -(001 project bli 'J1Cl' date design 1 rsp no. sheet MAY -30 -1997 09841 FROM RSP i EQE Project Data South Central School District 4240 South 144' Street Tukwila, WA 98168 A&TN Kevin Faker TO 9018016 P.02 DATE May 30, 1997 PRQIELr Thorndyke Elementary School - Roof Framing Review PROJECT NO. 150626.01 HY Greg Gilds Memorandum FE: Roof Framing Review We have completed our review of the existing roof framing for Thorndyke Elementary School. The purpose of the framing was to determine the adequacy of the framing to support a now roof membrane and 2" of rigid insulation. It is anticipated that the new materials will weigh less than 2.0 psi. (Based on core samples taking of the existing rooting, the maximum weight of the existing materials don not appear to exceed 8.0 psf,) Boned on our review, the additional weight of the new materials should not have a significant impact on the existing framing. The review did identify the header beam between the stage and gymnasium as being slightly deficient for the total design loads. It does not appear that this beam will pose a threat during the summer months when roof snow loads will be limited, but this condition should be addressed before the fall. It appears that the potential solution will involve cutting the upper roof ghalam beams to eliminate tau negative momeds over the stage beam. This will also reduce the loads to the stage beam. It is our understanding that Tukwila Elementary b identical to Thoradyke and that the framing would require the 15100 =Pahl. Our cat opinion for this repair is approximately $500 per building for a total construction cost of $1,000 for both schools. If you have any questions or need any additional information, please call ow office. Thank you. RECEIVED CITY OF TUKWILA MAY 3 0 1997 PERMIT CENTER \l iaplsys\wp\staf ajg \thorndyklthornpm2.rtf AR EQB International Company 1411 4th Avenue ISuildin8, Suite SOO Seattle. Washington 98 24.8268 South I SCHOOL COUNTY C KING 4640 SOUTH 144th STREET May 30, 1997 Mr. Duane Griffin, Building Official City of Tukwila 6200 Southcenter Blvd. Tukwila, WA. 98168 Dear Mr. Griffin: In connection with the application request of the South Central School District No. 406 reroof project at Thorndyke and Tukwila Elementary Schools, I am submitting a cash assignment in the amount of $1,500. This assignment is being made as a warranty that the district will embark upon structural corrections at both of the aforementioned locations as recommended by Greg Gilda, P.E., of RSP EQE. Furthermore, the district will ensure that this work is completed by August 31, 1997. Thank you for your consideration. If I may be of further assistance, please contact me at 901 -8003. • TUKWILA, WASHINGTON 98168 -4196 • PHONE: 901 -8000 Sincerely, Kevin A. Fuhrer CPA Manager of Business and Support Services • RECEIVED CITY OF TUKWILA MAY 3 0 1997 PERMIT CENTER SAN" Arra- Project Data To South Central School District DATE May 27, 1997 4240 South 144`h Street PROJECT Thorndyke Elementary School Tukwila, WA 98168 - Roof Framing Review PROJECT NO. 150626.01 ATTN Kevin Fuhrer BY Greg Gilda Memorandum RE: Roof Framing Review We have completed our review of the existing roof framing for Thorndyke Elementary School. The purpose of the framing was to determine the adequacy of the framing to support a new roof membrane and 2" of rigid insulation. It is anticipated that the new materials will weigh less than 2.0 psf. (Based on core samples taking of the existing roofing, the maximum weight of the existing materials does not appear to exceed 8.0 psf.) Based on our review, the additional weight of the new materials should not have a significant impact on the existing framing. The review did identify the header beam between the stage and gymnasium as potentially needing some strengthening for its existing condition. This condition will be reviewed further to determine what, if anything, needs to be done to strengthen the beam. This is not a current concern due to the lack of potential roof loads. It is our understanding that Tukwila Elementary is identical to Thorndyke and that the framing would not be significantly affected by the new roofing project. If you have any questions or need any additional information, please call our office. Thank you. CITY OP TUKWILA MAY 2 8 1997 PERMIT CENTER �s'dG�.ht� +s+- ;'!C•,Tlh ra'#Gate:xi..,,... none. r, er:. e. ::nu��*.'tx�wx�r- lurN:�ts. >e�+; Aa!;4'+fr5.4"ot .•• Thorndyke and Tukwila Elementary School Reroof Project Narrative on Existing Roof, Material Removal, and Material Installation Existing Roof Thorndyke and Tukwila Elementary Schools presently have their original roofs consisting of an asphalt built up system (BURS) with a smooth surface /aluminum coating on Tukwila and a mineral capsheet on Thorndyke. Each roof system is applied, over two (2) layers of fiberboard insulation. Each layer is one (1) inch thick and overlies the wood deck. Tukwila consists of 32,660 sqft. and Thorndyke spans 28,650. sqft. of roof systems respectively. Thorndyke was originally constructed in 1968 and Tukwila in 1962. Material Removal Both schools have experienced varying levels of roof leaks. During the spring and ' summer of 1996, the district commissioned the services of a structural engineer to assess the integrity of the structural beams at both schools. Based upon the results of that review, repair of four (4) beams occurred at Thorndyke. Tukwila Elementary was found to be in satisfactory condition. Core samples were also taken. The results indicated that the underlying layers of fiberboard insulation had not been saturated with moisture to the point where a complete tear -off would be warranted. Minor demolition of materials (wood deck and underlying insulation) may be called for in areas where roof leakage has been concentrated. Material Installation The district has awarded the bid for this work to Scholten Roofing, Inc. of Lynden, WA. The roofing contractor will approach the work in a two (2) phase fashion. Phase one will be the reroof of Thorndyke Elementary and will commence on May 26, 1997. Phase two will cover Tukwila and will commence on June 20, 1997. Weather permitting, both phases are anticipated to be one (1) week in duration. The roofing contractor will be applying a J.P. Steven's "Hi-Tuff' roof system (Elastomeric Sheet) with an additional two (2) inches of Polyiso insulation being installed. Material documentation is also submitted with this narrative and application. RECEIVED CITY OF TUKWILA MAY 2 8 1997 CITYRECD CITY MAY 2 81997 Dnfl em PERMIT CENTFq . ;:1::5,"1,7!ro':`AiS'a'•iGC !'S1.`AM':.y'�:ro: Apr: �..:. rca lsyR;�ratt;crG}7nY5•:1i^P`SSAti ili5;'? PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER M197 -0068 PROJECT NAME DEPARTMENT: BUILDING DIVISION r FIRE PREVENTION Q PLANNING DIVISION 0 PUBLIC WORKS fl STRUCTURAL 0 PERMIT COORDINATOR THORNDYRE ELEMENTARY SCHOOL DATE 5/28/97 DETERNIINATI N OF COMPLETENESS: (T,Th) COMPLETE NOT COMPLETE L COMMENTS DUE DATE NOT APPLICABLE 0 TUES /TSURS ROUTIN : PLEASE ROUTE d NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE APPROVALS OR CORRECTIONS: (ten days) APPROVED I 1 APPROVED W/ CONDITIONS REVIEWERS INITIAL 446. DUEDATE 6/11/97 NOT APPROVED (attach comments) E1 DATE S' 61 al CORRECTION DETERMINATION: DUE DATE APPROVED I I APPROVED W/ CONDITIONS NOT APPROVED (attach comments) Q REVIEWERS INITIAL DATE (Cerdficadon of occupancy required. ) r.DATr _C MAY-06-1997 11:57 - L SCHOLTEN ROOFING INC 4-0E7004 TO CIIIPLAY NlRAIj P.02 "`t .•4t. '-•• ;' 1 • k. L1).4." - • • vit 4 --r -k' NC' AL' • • -VIM ^41 •• •./ • r . • STATE OF WASHINGl'ON'. • •••,??3,--14,• - • ,...44, / 44. ' -44' . • lg.., t . 4 :1114Wit4.1 %*•1. •:••■r': ••• •• q_t • ...te '44 ...• f. g,.. • I • .* • 1.• • .0. • 1.5 • •• ," • • • •• •• • .0 . • *: 'I • • • • '• • • • a ..... • • LOMA*, YO DISPLAY ,uTIJ •• e• moo se • *1 a .0 • • • • ••• ••••••••• RECEIVED CITY OF TUKWILA 2 8 1997 PERMIT CENTER